Loading...
HomeMy WebLinkAbout42132-Z �oUEFflj, �p Town of Southold '12/20/2018 P.O.Box 1179 a 53095 Main Rd ,per' Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 40120 Date: 12/20/2018 THIS CERTIFIES that the building COMMERCIAL Location of Property: 31775 Route,25, Cutchogue SCTM#: 473889 Sec/Block/Lot: 97.-5-11 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/2/2017 pursuant to which Building Permit No. 42132 dated 11/13/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: heating and,cooling system in existing commercial building as applied for. The certificate is issued to New York Telephone Co of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 42132 12/14/2018 PLUMBERS CERTIFICATION DATED \54� 7 ' e ignature TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE o . SOUTHOLD, NY y�jo1 � dao`` BUILDING PERMIT, (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 42132 Date: 11/13/2017 Permission is hereby granted to: New York Telephone Co Attn: Verizon PO BOX 2749 Addison, TX 75001 To: replace heating and cooling system in existing commercial building as applied for. At premises located at: i 31775 Route 25, Cutchogue SCTM # 473889 Sec/Block/Lot# 97.-5-11 Pursuant to application dated 11/2/2017 and approved by the Building Inspector. To expire on 5/15/2019. Fees: COMMERCIAL ADDITION/ALTERATION $250.00 CO -COMMERCIAL $50.00 Total: $300.00 ector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 , l ` Date. I Z`I I New Construction: Old or Pre-existing Building: V (check one) Location of Property: 0 �� 'V t a i n House No. Street Hamlet Owner or Owners of Property: v a m-eS T_-.)" n ' fl-9"-17 G Suffolk County Tax Map No 1000, Section —7 Block Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: / Request for: Temporary Certificate Final Certificate: ✓ (check one) Fee Submitted: $ W1jS1re r ho��pF SO!/T�,®lo Town Hall Annex Telephone(631)765-1802 54375 Main Road N Fax(631)765-9502 P.O.Box 1179 G Q Southold,NY 11971-0959 .O • �® roper.richert(-)town.southold.ny.us lycou�,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: New York Telephone Co (Verizon) Address: 31775 Route 25 city,Cutchogue st: New York zip: 11935 Building Permit#: 42132 Section: 97 Block: 5 Lot: 11 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Vicon Electric License No: 48149-ME SITE DETAILS Office Use Only Residential Indoor X Basement Service Only Commerical X Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 1 Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches 3 Twist Lock Exit Fixtures TVSS El Other Equipment: "Roof Mounted HVAC Equipment". Notes. 6- Light Fixtures, 3- Fans (120V-20A) 1-AC Unit (208V, 3 Phase, 20A) 200A Panel (120-208V). Inspector Signature: Date: June 8, 2018 0-Cert Electrical Compliance Form.xls OF SOUTyo� # # TOWN OF SOUTHOLD BUILDING DEPT. °yco 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ CAULKING REMARKS: DATE �� INSPECTOR OF SO!/ly0lo f # TOWN OF SOUTHOLD BUILDING DEPT. oourm N�' 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] 1LATION [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE INSPECTOR .p FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(IST) v ►- � y ------------------------------------ C FOUNDATION (2ND) N z 0 C1� ROUGH FRAMING& (n H PLUMBING N t� INSULATION PER N.Y. H STATE ENERGY CODE urrm Aiy Le i FINAL Z ADDITIONAL COMMENTS e � C z rn 1 �-3 H Cq . 0 b H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUI-hDINd DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 ���� � Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.0' Application Flood Permit Examined ,20 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Ll 2 ,ns l Approved 3 ,20 !� Mail toAQD & A Disapproved a/c Phone: LO Expiration ,20 :A D D B ' ding ns or NOV ® 2 2017 A ICATION FOR BUILDING PERMIT BUILD DEPS Date , 20 TOWN OF SOUTHOLDINSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. -, f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing d re lations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signator applican or name,if-a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder C) IAUNFF,-- Name of owner of premises Tj 1 L-L rl (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section Block Lot Subdivision Filed Map No. Lot a ti 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy e,l� j"�O C v 0 b. Intended use and occupancC. D . 3. Nature of work(check which applicable): New Building Addition Alteration x Repair Removal Demolition Other Work (Description) 4. Estimated Cost d ® 1000 Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 2) — C',<,n iam d 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises?YES NO 14. Names of Owner of premisesdX1f1Q Address SMld-{tet-fbwn 1 I-1&"1 Phone No. Name of Architect n Man �a E'> Address �0 1 ��(�,rv,c�. Phone No��� Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO� * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) �ny" e s on being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the V M& r& (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. X, Sworn t before me this day of OC 2 2-blic, JORIE R. ROOKotarry New York State �M1 Qualified in Suffolk County Notary Public My Commission Expires May 10, 20 HI Siature of Applicant g1SEF01,� BUILDING DEPARTMENT- Electrical Inspector �p TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 o • Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 roger.richert(c)town.southold.ny.us APPLICATION FOR ELECTRICAL INSPECTION EQU-ESTED BY: Date, Date: - Company Name: Uj�1 Name: - K I License No.: — ryl( - email: C U% NU e_(4& � • e�r�. Address: C 144r-�nr1 L r J ✓i rvol'A, rJ - Phone No.: VV C 31 - 7tro( '- S��I JOB SITE INFORMATION: (All Information Required) Name: ; Zo Address: '' �— Cross Street: Phone`No.: Bldg.Permit#: 3 email: ,m e Tax Map District: 1000 Section: Block: Lot: 44 BRIEF DESCRIPTION OF WORK (Please P ' t Clearly) — Q1 A.I (21__1t11A Z ,J4A1 Circle All That Apply: Is job ready for inspection?: ES NO Rough In Final Do you need a Temp Certificate?: YES Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect- Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Informatio PAYMENT DUE WITH APPLICATION 011 Request for Inspection FormAs JJacobsen&Horan Engineering,P.C. 990 South 2°d Street Letter of Transmittal Ronkonkoma,IVY 11779 H Tel. (631)580-6100 Fag:(631)580-6101 To: Town of Southold Attention: Building Department Building Department From: Liz Bristoll Town Hall Southold, NY 11971 JHE Proj. No.: 17-2165 Client Proj. No.: - Date: November 2, 2017 Re: Verizon: 31755 Main Rd, Cutchogue; A/C Replacement for Carrier Switchroom Materials Enclosed: ry Sealed Drawing(s) Specification(s) 17y, For Your Information r-1 For Your Approval Cj Reproducible(s) Filing Form(s) Per Your Requestj Return to JHE Print(s) ForSubm ittal(s) � For Your Comment IJ Distribution Other j Refer to Attachments)for Comment(s) Copies Dwg.No. Date Description 4 various 11/02/17 24x36 Issued for Filing Drawing Set—Signed and Sealed 4 - 11/01/17 ComCheck—Signed and Sealed 4 - 11/01/17 Heat Load Calculations—Signed and Sealed 1 - 10/24/17 Building Permit Application 1 - 10/24/17 Application for Certificate of Occupancy 1 - 11/01/17 Check for Building Permit and Certificate of Occupancy fees Remarks: For filing. Copies To: File Via: USPS rV-1 FedEx Letter Packr, overnight f Ground Email r-( Hand Tube Box 2-Day r!!-� Express Saver 1 w �6 Jacobsen & Horan Engineering, P.C. H Heating & Cooling Load Calculations Prepared for: Verizon C.O. located at 31755 Main Road, Cutchogue, NY 11935 Calculation Summary Compliance Table Area(System) Calculated Cooling Calculated Cooling Specified Cooling Load Load (Btu/hr) Load (tons) (tons) Entire Building 313-01-01 /210-1 R-01 276,200 23 30 (15 each) &313-01-02/210-1 R- 02 The Trane Company's TRACE 700 (version 6.3.2.2) Building Load and Energy Analysis Software was used for this calculation. *` Heating and cooling load calculations were performed in compliance with Section 312.1 of the 2015 International Mechanical Code. OF NF AP R VED AS NOTED Q� ET H J, do J-0 ® DATE: 1. B.P.# 3A �� 7 C CY O USE ur FEE: I UNLAWFUL NOTIFY B!.1,, s:" �� AT mWITHOUT CERTIFICA i 1- 765-1802 8 AM TO -I r,6 FOR THE FOLLOWING INSPECTIONS: ��,o ��3573 C?� F OCCUPANCY 1. FOUNDATION - TWO REQUIRED '94F �,�� FOR POUREn NI"".- RETE �SSIONP s ����°������ 2. ROUGH - PLUMBING WSPEC T90N R QU0Rj L) 3. INSULA' 4. FINAL MUST COMPLY WITH ALL CODES OF BE COM, s NEW YORK STATE & TOWN CODE` ALL CONST SHALL MEET THE AS REQUIRED AND CONDITIONS — REQUIREMEP, �:`THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR � °� ,` DESIGN OR CONSTRUCTION ERRORS. � � " ' REQUIRED BEFC f"<<w SSW ARD MIN 990 SOUTH 2ND ST. RONKONKOMA, NY 11779 O: (631) 580-6100 F. (631)580-6101 System Checksums By Jacobsen & Horan Engineering, P.C. 313-01-01 &313-01-02 Packaged Terminal Air Conditioner COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK TEMPERATURES Peaked at Time: Mo/Hr: 8/16 Mo/Hr:Sum of Mo/Hr: Heating Design Cooling Heating Outside Air. OADB/WB/HR. 88/75/113 OADB:Peaks OADB. 15 SADB 61.5 72.7 Ra Plenum 75.3 693 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 75.1 700 Sens.+Lat. Sens.+Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 75.3 700 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.0 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.0 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 000 Fn Frict 0 0 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 5,886 709 6,595 2 8,267 3 Roof Cond -12,214 -13,777 19.98 Glass Solar 0- 0 0 0 0 0 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 243 0 243 0 258 0 Glass/Door Cond -1,243 -1,243 1.80 Cooling Heating Wall Cond 8,096 122 8,218 3 8,475 3 Wall Cond -12,356 -12,510 18.15 Diffuser 16,598 16,598 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 16,598 16,598 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0 Main Fan 16,598 16,598 Infiltration 18,911 18,911 7 4,905 2 Infiltration -24,659 -24,659 35.77 Sec Fan 0 0 Sub Total=_> 33,135 831 33,967 12 21,904 9 Sub Total=_> -50,473 -52,189 75.70 Nom Vent 274 0 AHU Vent 274 0 Internal Loads Jnternal Loads Infil 402 402 Lights 7,483 1,871 9,353 3 7,483 3 Lights 0 0 0.00 MinStop/Rh 0 0 People 1,350 0 1,350 0 750 0 People 0 0 0.00 Return 17,000 17,000 Misc 218,842 0 218,842 79 218,842 88 Misc 0 0 0.00 Exhaust 676 402 Sub Total=_> 227,674 1,871 229,545 83 227,074 91 Sub Total=_> 0 0 0.00 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 68 -68 0 0 67 0 Ceiling Load -143 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 12,898 5 0 0 Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid.Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 0 0 0 0 0 Exhaust Heat 26 -0.04 ENGINEERING CKS Exhaust Heat -216 -216 0 OA Preheat Diff. -12,820 1860 Sup.Fan Heat 0 0 RA Preheat Diff. -3,957 5.74 Cooling Heating Ret.Fan Heat 0 0 0 Additional Reheat 0 0.00 %OA 1.7 00 Duct Heat Pkup 0 0 0 cfm/ft2 3.03 303 Underfir Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 721 15 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft2/ton 238.14 Btu/hr•ft2 50 39 -12.30 Grand Total==> 260,877 2,419 276,194 100.00 249,046 100.00 Grand Total==> -50,616 -68,940 100.00 No.People 3 COOLING COIL SELECTION AREAS HEATING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass CapacityCoil Airflow Ent Lvg ton MBh MBh cfm OF OF gr/Ib OF OF gr/Ib ft2 (%) MBh cfm OF OF Main Clg 23.0 276.2 252.9 16,598 75.3 62.8 65.7 61.5 57.4 63.9 Floor 5,481 Main Htg -67.4 16,598 69.1 72.7 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 00 0.0 0.0 0.0 Part 0 Aux Htg 0.0 0 0.0 00 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Int Door 0 Preheat 0.0 0 0 0 0.0 ExFlr 0 Total 23.0 276.2 Roof 5,481 0 0 Humidif 0.0 0 0.0 0.0 Wall 3,522 0 0 Opt Vent 0.0 0 0.0 0.0 Ext Door 32 0 0 Total -67.4 Project Name. TRACE®700 v6.3.2 calculated at 03.07 PM on 11/01/2017 Dataset Name: 16-2165 Heat Loads.trc Alternative-1 System Checksums Report Page 1 of 1 COMcheck Software Version 4.0.7.0 Interior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: A/C Replacement for Carrier Switchroom Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 31755 Main Rd. Jacobsen& Horan Engineering, P.C. Cutchogue, NY 11935 990 South 2nd St. Suite 2 Ronkonkoma, NY 11779 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-MER(Office) 342 0.82 280 Total Allowed Watts= 280 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. MER (Office 342 sq.ff.). LED 1:A/A-EM:4F7 LINEAR LUMINAIRE:Other: 1 5 43 215 Total Proposed Watts= 215 Interior • • PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.7.0 and to comply with any applicable mandatory requirements listed in the Inspect!o Checklist. Paul Jacobsen, P.E. E 11/1/17 Name-Title SicrhatuDate JA Co ;S, r �I � .• �r�'w tD 076464 A9QFESSt4��'`� Project Title: A/C Replacement for Carrier Switchroom Report date: 10/31/17 Data filename: \\SERVER2\Projects\17-2165\Misc\ComCheck\2165.cck Page 1 of 11 COMcheck Software Version 4.0.7.0 Mechanical Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: A/C Replacement for Carrier Switchroom Location: Cutchogue, New York Climate Zone: 4a Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 31755 Main Rd. Jacobsen &Horan Engineering, P.C. Cutchogue, NY 11935 990 South 2nd St. Suite 2 Ronkonkoma, NY 11779 Mechanical Systems List Quantity System Type&Description 2 313-01-01,313-01-02(Single Zone): Cooling:1 each-Computer Room AC Upflow Unit,Capacity=198 kBtu/h,Glycol-Cooled Condenser,Fluid Economizer Proposed Efficiency=2.01 SCOP-127,Required Efficiency: 1.99 SCOP-127 Fan System: SUPPLY Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Constant Volume,6000 CFM,3.0 motor nameplate hp,70.0 fan efficiency grade Mechanical Compliance Statement Compliance Statement. The proposed mechanical alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permi .The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck Versi ! �� ply with any applicable mandatory requirements listed in the Inspection Checklist. `i H J Ken Horan, P.E. '��� ®�® 11/1/17 Name-Title Signat Id 'yZ Date r � a 0 cc 07357 A9CFESSIONP R Project Title: A/C Replacement for Carrier Switchroom Report date: 10/31/17 Data filename: \\SERVER2\Projects\17-2165\Misc\ComCheck\2165.cck Page 2 of 11 COMcheck Software Version 4.0.7.0 Inspection Checklist Energy Code: 2015 IECC Requirements: 95.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section' #: PIan�Review Complies? ' ,comnneiits/Assu-mptioris & R"eq.ip C103.2 !Plans,specifications, and/or E❑Complies ;Requirement will be met. [PR2]1 ;calculations provide all information ❑Does Not with which compliance can be ;determined for the mechanical ;❑Not Observable i !systems and equipment and ❑Not Applicable document where exceptions to the ;standard are claimed. Load 'calculations per acceptable ;engineering standards and !handbooks. C103.2 ;Plans,specifications,and/or !❑Complies :Requirement will be met. [PR4]1 :calculations provide all information ❑Does Not :with which compliance can be :Location on plans/spec: E102, E501 (Lighting Fixture :determined for the interior lighting ;❑Not Observable: and electrical systems and equipment i❑Not Applicable :and document where exceptions to ;the standard are claimed. Information 'provided should include interior ' :lighting power calculations,wattage of bulbs and ballasts,transformers and !control devices. Additional Comments/Assumptions: 11 High Impact(Tier 1) 1 2_ Medium Impact(Tier 2) 3. Low Impact(Tier 3) Project Title: A/C Replacement for Carrier Switchroom Report date: 10/31/17 Data filename: \\SERVER2\Projects\17-2165\Mist\ComCheck\2165.cck Page 3 of 11 eCi011 # noting%Founiiation Inspection Complies?' CommentslAssucr%ptiphs eq. 0403.2.4. 'Snow/ice melting system sensors for i❑Complies !Exception: Requirement does not apply. 5, ; future connection to controls. Freeze ❑Does Not C403 2: 4. :protection systems have automatic 6 :' ;controls installed. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 IHigh Impact(Tier 1) 2. Medium Impact(Tier 2) 1,3 1 Low Impact(Tier 3) Project Title: A/C Replacement for Carrier Switchroom Report date: 10/31/17 Data filename: \\SERVER2\Projects\17-2165\Mist\ComCheck\2165.cck Page 4 of 11 # a Pluriibing Rough-in'Inspection Gomplies,2. t Comments/Assumptions. --&R eq.IQ; kn C404.5,, Heated water supply piping conforms ;❑Complies !Exception: Requirement does not apply. 0404:5.1; to pipe length and volume ❑Does Not C404.5.2, requirements. Refer to section details. (BL6]3 " ;❑Not Observable: ❑Not Applicable 0404':6:3 'Pumps that circulate water between a i❑Complies :Exception: Requirement does not apply. [PL7]3 . heater and storage tank have controls :❑Does Not that limit operation from startup to <= 5 minutes after end of heating ❑Not Observable :cycle. ❑Not Applicable '0404.7 •,.Water distribution system that pumps ?❑Complies :Exception: Requirement does not apply. water from a heated-water supply ❑Does Not pipe back to the heated-water source ; through a cold-water supply pipe is a i❑Not Observable demand recirculation water system. ❑Not Applicable Pumps within this system have controls that startthe pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Additional Comments/Assumptions: 11 High Impact(Tier 1) ` Medium Impact(Tier 2) 3` Low Impact(Tier 3) Project Title: A/C Replacement for Carrier Switchroom Report date: 10/31/17 Data filename: \\SERVER2\Projects\17-2165\Misc\ComCheck\2165.cck Page 5 of 11 Section. µ, # ;Mechanical Ro49h,4nAnspection; Complies?, Comments/Assumptimns, ° C402:Z6 .:Thermally ineffective panel surfaces of;❑Complies ;Exception: Requirement does not apply. [ME41]3' sensible heating panels have ;❑Does Not ;insulation >= R-3.5. I ❑Not Observable ❑Not Applicable C4034.13-, Unenclosed spaces that are heated ?❑Complies :Exception: Requirement does not apply. [ME71]2 : use only radiant heat. ❑Does Not ❑Not Observable ❑Not Applicable C403`.2:3 , HVAC equipment efficiency verified. i❑Complies :See the Mechanical Systems list for values. [ME55]? ❑Does Not ❑Not Observable ❑Not Applicable C403.2.6. :Demand control ventilation provided i❑Complies !Exception: Requirement does not apply. 1 ;for spaces >500 ft2 and >25 ;❑Does Not [ME59]1 people/1000 ft2 occupant density and served by systems with air side ;❑Not Observable 'economizer, auto modulating outside ;❑Not Applicable air damper control, or design airflow >3,000 cfm. C403.2',6: :Enclosed parking garage ventilation :❑Complies :Exception: Requirement does not apply. 2 3 has automatic contaminant detection ❑Does Not [ME115]3 {and capacity to stage or modulate 3fans to 50%or less of design capacity. ❑Not Observable ❑Not Applicable C403.2.7 1 Exhaust air energy recovery on ;❑Complies :Exception: Requirement does not apply. [ME57]1 :systems meeting Table C403.2.7(1) ❑Does Not and C403.2.7(2). ❑Not Observable: ❑Not Applicable 0403.2:8-' Kitchen exhaust systems comply with ?❑Complies ;Exception: Requirement does not apply. [ME116]3..:replacement air and conditioned ❑Does Not !supply air limitations, and satisfy hood s rating requirements and maximum ;❑Not Observable - !exhaust rate criteria. ❑Not Applicable 04,03.2:9 HVAC ducts and plenums insulated. :❑Complies :Requirement will be met. [ME60]2'. ` Where ducts or plenums are installed 1EIDoes Not in or under a slab,verification may :Location on plans/spec: M102, M603 need to occur during Foundation ;❑Not Observable ❑Not Applicable Inspection. 04012.9,'` Ducts and plenums sealed based on :❑Complies :Requirement will be met. [ME10P ' 'static pressure and location. ❑Does Not Location on plans/spec: M603 i '❑Not Observable: ❑Not Applicable C403.2:9,.I Ductwork operating >3 in.water ?❑Complies :Exception: Requirement does not apply. 1.3 icolumn requires air leakage testing. ::❑Does Not [MEl'1]3• } :Location on plans/spec: M603 ❑Not Observable: ❑Not Applicable 0403.4:4':,',Multiple zone VAV systems with DDC i❑Complies :Exception. Requirement does not apply. '6sof individual zone boxes have static �❑Does Not [ME1fQ.]3 s pressure setpoint reset controls. ❑Not Observable:See the Mechanical Systems list for values. :❑Not Applicable C4,08.2;2. 'Air outlets and zone terminal devices �❑Complies ;Requirement will be met. 1 _ .1 have means for air balancing. ❑Does Not [ME53]3 ❑Not Observable:Location on plans/spec: M602 ! ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2,,l Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: A/C Replacement for Carrier Switchroom Report date: 10/31/17 Data filename: \\SERVER2\Projects\17-2165\Mist\ComCheck\2165.cck Page 6 of 11 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: A/C Replacement for Carrier Switchroom Report date: 10/31/17 Data filename: \\SERVER2\Projects\17-2165\Misc\ComCheck\2165.cck Page 7 of 11 Section• - . . , .. ;"Sum' Rough-lie Electiical'Inspectiota Complies? Comments/Assum'ptions & Req:ID F C405.2.1 i Lighting controls installed to uniformly;❑Complies !Requirement will be met. [EL15]1 !reduce the lighting load by at least !DDoes Not 150%. !Location on plans/spec: E102 (Area controlled via i !DNot Observable: occupancy sensor) ;❑Not Applicable C405.2.1 !Occupancy sensors installed in !❑Complies :Requirement will be met. [EL18]1 :required spaces. i❑Does Not i ❑Not Observable!Location on plans/spec: E102 j ❑Not Applicable t465.-7.1,1 Independent lighting controls installed ;❑Complies !Requirement will be met. C405:2.2s, per approved lighting plans and all ❑Does Not manual controls readily accessible and: !Location on plans/spec: E102 [EL23]2 ' #visible to occupants. ;❑Not Observable !❑Not Applicable C4052.2:{'Automatic controls to shut off all ;❑Complies !Exception: Lighting controlled by occupancy sensors. I : building lighting installed in all '❑Does Not [EL•22]2 buildings. 'Location on plans/spec: E102 I ❑Not Observable: ❑Not Applicable C405:2:3 ' Daylight zones provided with ;❑Complies !Exception: Requirement does not apply. [naw,,-. individual controls that control the ::❑Does Not lights independent of general area lighting. ❑Not Observable: !❑Not Applicable C405.2.3, !Primary sidelighted areas are !❑Complies !Exception: Requirement does not apply. C405.2.3. !equipped with required lighting ❑Does Not 1, 1 controls. ! C405.2.3. E ❑Not Observable 2 ❑Not Applicable [EL20]1 I C405.2.3, !Enclosed spaces with daylight area i❑Complies !Exception: Requirement does not apply. C405.2.3. :under skylights and rooftop monitors '❑Does Not 1, !are equipped with required lighting C405.2.3. !controls. ;❑Not Observable! 3 ! ;❑Not Applicable [EL21]1 ! C405.2.4 !Separate lighting control devices for i❑Complies !Location on plans/spec: Requirement does not apply. [EL4]1 !specific uses installed per approved '❑Does Not lighting plans. !❑Not Observable: ❑Not Applicable C405.2.4 !Additional interior lighting power i❑Complies :Location on plans/spec: Requirement does not apply. [EL8]1 'allowed for special functions per the ❑Does Not !approved lighting plans and is !automatically controlled and ;❑Not Observable! 'separated from general lighting. ;❑Not Applicable C405.3 !Exit signs do not exceed 5 watts per !❑Complies !Requirement will be met. [EI-611 !face. ;DDoes Not Location on plans/spec: E102, E501 (Lighting Fixture '❑Not Observable;Schedule) ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2', Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: A/C Replacement for Carrier Switchroom Report date: 10/31/17 Data filename: \\SERVER2\Projects\17-2165\Mist\ComCheck\2165.cck Page 8 of 11 Section n # :Fin al'I'nspecfion Complies,? Comments/Assu"mpto6ns� x''t -&,Re4Jp C303.3; Furnished O&M instructions for E❑Complies :Requirement will be met. 0408.2:5.:!systems and equipment to the ❑Does Not 2 (building owner or designated [Fi17]3' representative. '❑Not Observable ❑Not Applicable -:i 0303.3, .;Furnished O&M manuals for HVAC !❑Complies ;Requirement will be met. 0408.25. (systems within 90 days of system ::❑Does Not 3'° ` acceptance. ❑ [FI8]3 Not Observable ❑Not Applicable C403.2:2­' HVAC systems and equipment E❑Complies :Requirement will be met. [F127] • capacity does not exceed calculated ❑Does Not loads. ❑Not Observable Location on plans/spec: REFER TO HEAT LOAD x_ ❑Not Applicable ;CALCULATIONS C4403.2.4: Heating and cooling to each zone is E❑Complies ;Requirement will be met. 1 v, controlled by a thermostat control. ::❑Does Not [F147]3, Minimum one humidity control device :Location on plans/spec: M102, M502 per installed E❑Not Observable: humidification/dehumidification ❑Not Applicable system. 6403.2:4.. Thermostatic controls have a 5 °F E❑Complies :Exception: Precision indoor temperature control required. deadband. ?❑Does Not IFI38]3' t # ❑Not Observable ❑Not Applicable C403.2:4'. Temperature controls have setpoint E❑Complies i Exception: Requirement does not apply. 1.3' overlap restrictions. ::[:]Does Not [F120j3 ❑Not Observable i ❑Not Applicable C403.2.4., Each zone equipped with setback ;❑Complies :Exception: Zones operated continuously. 2.' ` ;controls using automatic time clock or i❑Does Not [FI39]3 programmablecontrol system. ❑Not Observable: ❑Not Applicable C403:2:4. Automatic Controls: Setback to 55°F E❑Complies ;Exception: Requirement does not apply. 21, '(heat) and 85°F(cool); 7-day clock, 2- ❑Does Not C403:2.4. hour occupant override, 10-hour 2:2 backup ;❑Not Observable [F140V.,.p; ❑Not Applicable .0403.2,.4. Systems include optimum start E❑Complies ;Requirement will be met. 2.3 •;- controls. ❑Does Not [F141]3 ;Location on plans/spec: M502 ❑Not Observable :[:]Not Applicable C405.4.1 i Interior installed lamp and fixture UComplies !See the Interior Lighting fixture schedule for values. [FI18]1 !lighting power is consistent with what ❑Does Not !is shown on the approved lighting E iplans,demonstrating proposed watts E❑Not Observable; are less than or equal to allowed ❑Not Applicable !watts. C408.2.1 Commissioning plan developed by E❑Complies ;Requirement will be met. [FI28]1 ;registered design professional or ❑Does Not :approved agency. ❑Not ObservableLocation on plans/spec: COMMISSIONING NOT REQUIRED, ❑Not Applicable MECHANICAL SYSTEM LESS THAN 480,000 BTU/H C408.2.3. E HVAC equipment has been tested to E❑Complies :Exception: Unitary or packaged HVAC eqiupment without 1 ;ensure proper operation. :❑Does Not !supply air economizers. [FI31]1 ! ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low'lmpact(Tier 3) Project Title: A/C Replacement for Carrier Switchroom Report date: 10/31/17 Data filename: \\SERVER2\Projects\17-2165\Mist\ComCheck\2165.cck Page 9 of 11 ' ;Section. °, • # Final Inspection Complies? `y Cor»mems/A'ssumptions- " &,Req.ID' C408.2.3. :HVAC control systems have been 1❑Complies !Requirement will be met. 2 ;tested to ensure proper operation, ❑Does Not [17110]1 :calibration and adjustment of controls. ;❑Not Observable ❑Not Applicable C408.2.3. !Economizers have been tested to i❑Complies i Requirement will be met. 3 :ensure proper operation. ::F-]Does Not [F132]1 ❑Not Observable ❑Not Applicable C408.2.4 !Preliminary commissioning report ;❑Complies !Requirement will be met. [FI29]1 !completed and certified by registered 1EIDoes Not ;design professional or approved ;❑Not ObservableLocation on plans/spec: COMMISSIONING NOT REQUIRED, j agency. MECHANICAL SYSTEM LESS THAN 480,000 BTU/H ❑Not Applicable ; 0408:2:5.'. Furnished HVAC as-built drawings ;❑Complies !Requirement will be met. 1 submitted within 90 days of system ❑Does Not [F17]3, acceptance. ❑Not Observable ❑Not Applicable C408:2.5. Furnished as-built drawings for ;❑Complies :Requirement will be met. 'T. electric power systems within 90 days :[]Does Not [FI16]3 of system acceptance. ❑Not Observable :[-]Not Applicable C408.2.5. ;An air and/or hydronic system !❑Complies !Requirement will be met. 3 balancing report is provided for HVAC ❑Does Not [F143]1 ;systems. Location on plans/spec: M602 f ❑Not Observable ❑Not Applicable C408.2.5. :Final commissioning report due to i❑Complies ;Requirement will be met. 4 building owner within 90 days of ❑Does Not [F130]1 'receipt of certificate of occupancy. ❑Not Observable Location on plans/spec: COMMISSIONING NOT REQUIRED, { :MECHANICAL SYSTEM LESS THAN 480,000 BTU/H ❑Not Applicable C408.3 Lighting systems have been tested to E❑Complies :Requirement will be met. [F133]1 ;ensure proper calibration,adjustment, i❑Does Not programming, and operation. Location on plans/spec: E601 ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) ='3 Low Impact(Tier 3) Project Title: A/C Replacement for Carrier Switchroom Report date: 10/31/17 Data filename: \\SERVER2\Projects\17-2165\Misc\ComCheck\2165.cck Page 10 of 11 s � Project Title: A/C Replacement for Carrier Switchroom Report date: 10/31/17 Data filename: \\SERVER2\Projects\17-2165\Misc\ComCheck\2165.cck Page 11 of 11 i Srr'E, '�,MORMATION -, KEY PLAN BURDDING ADDIXM: 305 MAIN RD CUrCHOOM NY Jacobsen & Horan APPROVED AS NOTED Engineering, P.C. DATE: 11_ �.�.# �3z U P %N ;Y OR 990 South 2nd Street OCC Ronkonkoma, NY 11779 °em I "N' AWFUL O: (631) 580-6100 NOTIFY 13'.� . :.TENT AT U _. (631) 580-610 1 765.1$02 BAiA i) .,rIJ FOR THE WITT ,ERTIFICAT FOLLOWING INSPECTIONS: www.jhepc.com , FOUNDATION - TWO REQUIRED OF Ou 7UF .ANCY FOR POURED flONCRETE 2. ROUGH . "'"'`�` PLUMBING G: IT IS A VIOLATION OF NEW YORK P 3, INSULA' ' t���O F ^'FGy STATE EDUCATION LAW FOR ANY MUST FLED °�� . rn,L- �` ��GT H j, PERSON, UNLESS ACTING UNDER 4 FINAL. THE OF A PROFESSIONAL ENGINEER, TO BE 0014:= MEET THE INSPECTIO J RI *� �� 0� ALTER AN ITEM ON THIS DRAWING ALL CONS; SHAD T� IN ANY WAY. IF AN ITEM IS i HE CODES OF NEW r �a �•y Z ALTERED, THE ALTERING ENGINEER ,Q(JIREME; m f �'` SHALL AFFIX TO THE ITEM N; GENERAL NOTES FOR CONSTRUCTION FINISH NOTES PRODUCTS AND SUBSTITUTIONS CUTTING AND PATCHING 1. INFORMATION SHOWN ON THESE DRAWINGS IS FOR DESIGN INTENT ONLY. VERIFY EXISTING 1. PAINTING OR INTERIOR FINISHING SHALL NOT BE DONE UNDER CONDITIONS WHICH WILL 1• REQUESTS FOR CHANGES IN THE PRODUCTS, MATERIALS, EQUIPMENT AND METHODS OF CUTTING AND PATCHING REQUIRED SHALL BE DONE IN ACCORDANCE WITH THE BUILDING CODE CONDITIONS AND DIMENSIONS IN FIELD. COORDINATE DISCREPANCIES WITH THE ARCHITECT AND/OR JEOPARDIZE THE QUALITY OR APPEARANCE OF SUCH WORK. WORKMANSHIP, WHICH IS CONSTRUCTION REQUIRED, BY THE CONTRACT DOCUMENTS ARE CONSIDERED REQUESTS FOR OFTHE CITY OF NEW YORK. ENGINEER. DO NOT SCALE DRAWINGS TO DETERMINE DIMENSIONS. JUDGED LESS THAN FIRST QUALITY BY THE ARCHITECT, WILL BE REJECTED. "SUBSTITUTIONS", AND ARE SUBJECT TO THE FOLLOWING ITEMS: WHERE CUTTING AND PATCHINQ.INVOLVES ADDITION OF REINFORCEMENT OF STRUCTURAL 2. SUBMIT COLORS TO THE ARCHITECT, FOR APPROVAL. ELEMENTS, SUBMIT DETAILS AND ENGINEERING CALCULATIONS TO SHOW HOW REINFORCEMENT IS 2. ESTABLISH LINES, GRADES AND BENCHMARKS NECESSARY FOR PROPER WORK. FURNISH GIVEN A. REVISIONS TO THE CONTRACT DOCUMENTS, WHERE REQUESTED BY THE OWNER, ARCHITECT SURVEY DATA. 3. PREPARE SURFACES TO RECEIVE THE SPECIFIED FINISH. TAPE AND SAND SMOOTH OR ENGINEER, ARE CONSIDERED AS "CHANGES", NOT SUBSTITUTIONS. INTEGRATED WITH ORIGINAL STRUCTURE. 3. BE RESPONSIBLE FOR QUANTITIES OF WORK. FURNISH LABOR, MATERIALS AND EQUIPMENT GYPSUM BOARD TO RECEIVE THE SPECIFIED FINISH. PAINT GRADE WOODWORK SHALL BE HAND SANDED BETWEEN COATS AND DUSTED CLEAN. ALL HOLES, PITCH POCKETS OR B. SPECIFIED CONTRACTOR OPTIONS ON PRODUCTS AND CONSTRUCTION METHODS INCLUDED IN DO NOT CUT AND PATCH STRUCTURAL ELEMENTS IN A MANNER THAT WOULD REDUCE THEIR REQUIRED TO COMPLETE WORK. SAPPY PORTIONS SHALL BE SCRAPED AND SHELLACKED, THE CONTRACT DOCUMEMTS ARE CHOICES AVAILABLE TO THE CONTRACTOR AND ARE NOT LOAD-CARRYING CAPACITY OR LOAD-DEFLECTION RATIO. 4. PROVIDE PROOF OF WORKMAN'S COMPENSATION INSURANCE AND DISABILITY INSURANCE COVERAGE 4. FILL CRACKS, HOLES, IMPERFECTIONS IN EXISTING WALLS, PARTITIONS, OR GYPSUM SUBJECT TO THE REQUIREMENTS FOR SUBSTITUTIONS. OBTAIN APPROVAL FROM A LICENSED STRUCTURAL ENGINEER PRIOR TO THE CUTTING AND REQUIRED BY GOVERNING STATE LAW PRIOR TO START OF WORK. BOARD WITH PATCHING PLASTER AND SMOOTH OFF TO MATCH ADJOINING SURFACES OR 2. CONTRACTOR'S DETERMINATION OF AND COMPLIANCE WITH GOVERNING REGULATIONS AND ORDERS, PATCHING OF THE FOLLOWING STRUCTURAL ITEMS: 5. COORDINATE DRYWALL WORK WITH THAT OF THE OTHER TRADES IF DRYWALL IS IN CONFLICT WITH LAMINATE WITH 1 LAYER OF 1/2" GYPSUM BOARD TO ACHIEVE REQUIRED SMOOTHNESS, AS ISSUED BY GOVERNING AUTHORITIES, DO NOT CONSTITUTE SUBSTITUTIONS" AND DO NOT A FOUNDATIONS DUCTWORK, PLUMBING LINES, ETC. AS PER ARCHITECT'S INSPECTION. CONSTITUTE A BASIS FOR CHANGE ORDERS, EXCEPT AS OTHERWISE PROVIDED IN THE CONTRACT B BEARING WALLS 5. WIPE NEW GYPSUM BOARD SURFACES WITH A DAMP CLOTH JUST PRIOR TO DOCUMENTS. Jacobsen & Horan 6. PROVIDE NECESSARY BRIDGING AND BRACING REQUIRED TO SECURE DRYWALL AND MAINTAIN FIRE C STRUCTURAL CONCRETE OR SOUND RATING WHERE INDICATED ON THE DRAWINGS. APPLICATION OF THE PRIMER, IN ORDER TO LAY FLAT ANY NAP WHICH MAY HAVE 3. TO THE FULLEST EXTENT" POSSIBLE, FURNISH AND INSTALL PRODUCTS OF THE SAME GENERIC D STRUCTURAL STEEL FORMED IN SANDING PROCESS. E LINTELS 7. PROVIDE METAL CORNER BEADS AT VERTICAL AND HORIZONTAL OUTSIDE CORNERS AND METAL "J" KIND, FROM A SINGLE SOURCE, FOR EACH UNIT OF WORK. PRODUCTS REQUIRED FOR THE WORK MOLDS AT EXPOSED EDGE CONDITIONS; SPACKLED AND FINISH TO FORM STRAIGHT AND SMOOTH 6. UPON COMPLETION OF PAINTING WORK, REMOVE ALL PAINT FROM WHERE IT HAS SHALL BE PROVIDED FROM RELIABLE SOURCES CAPABLE OF PRODUCING AND DELIVERING F STRUCTURAL WOOD FRAMING P.C. WALLS. SPILLED, SPLASHED, OR SPLATTERED ON EXPOSED ADJACENT SURFACES. UNIFORMLY ACCEPTABLE PRODUCTS, IN ACCORDANCE WITH CONTRACT TIME REQUIREMENTS. WHEN G MISCELLANEOUS STRUCTURAL METALS Engineering, 8. PROVIDE WATER RESISTANT GYPSUM BOARD FOR PARTITIONS ADJACENT TO PLUMBING LINES OR 7• EXAMINE FINISH SURFACES AFTER COMPLETION OF WORK INCLUDING MILLWORK IT IS DISCOVERED THAT `.SPECIFIED PRODUCTS ARE AVAILABLE ONLY FROM SOURCES THAT DO NOT H EQUIPMENT SUPPORTS 990 South 2nd Street FIXTURES. INSTALLATION AND PROCEED WITH "TOUCHUP" AS REQUIRED. OR CANNOT PRODUCE AN ADEQUATE QUANTITY TO COMPLETE PROJECT REQUIREMENTS IN A Ronkonkoma, NY 11779 g. 8. PROVIDE ARCHITECT WITH A MINIMUM OF (3) 8" X 10" BRUSH-OUTS OF EACH COLOR TIMELY MANNER, CONSULT WITH THE ARCHITECT FOR A DETERMINATION OF WHAT PRODUCT DO NOT CUT AND PATCH OPERATING ELEMENTS OR SAFETY RELATED COMPONENTS IN A BUILT-IN CABINET WORK SHALL BE ENCASED IN LAMINATE CLASS B FINISH COMPLETELY, ANY QUALITIES ARE MOST IMPORTANT BEFORE PROCEEDING. MANNER THAT WOULD RESULT IN REDUCING THEIR CAPACITY TO PERFORM AS INTENDED, OR 0: (631) 580-6100 EXPOSED FACE CABINETS SHALL UTILIZE FIRE RETARDANT WOOD MATERIAL. WOOD BLOCKING SHALL AND FINISH FOR ARCHITECT'S APPROVAL, AT LEAST 2 WEEKS PRIOR TO SITE RESULT IN INCREASED MAINTENANCE OR DECREASED OPERATIONAL LIFE OR SAFETY. BE PRESSURE TREATED WITH A FIRE RETARDATION. PROPERLY SEAL, SAND AND PRIME NEW WOOD APPLICATION. ON-SITE APPLICATIONS SHALL BE REQUIRED ONE WEEK PRIOR TO FINAL 4. COMPATIBILITY OF PRODUCTS IS A BASIC REQUIREMENT OF PRODUCT SECTION. WHEN THE F: 631( ) 580-6101 SURFACES TO RECEIVE FINISH COAT. APPROVAL. ARCHITECT RESERVES THE RIGHT TO ADJUST ANY COLOR / FINISH ONCE USE MATERIALS THAT ARE IDENTICAL TO EXISTING MATERIAL. IF IDENTICAL MATERIALS ARE NOT www jhepc.com THE WALL TEST HAS BEEN MADE. CONTRACTOR IS GIVEN THE OPTION OF SELECTING BETWEEN TWO OR MORE PRODUCTS FOR USE AVAILABLE OR CANNOT BE USED WHERE EXPOSED SURFACES ARE INVOLVED, USE MATERIALS g 10. SET CEILING HEIGHTS AS INDICATED ON THE DRAWINGS MEASURED, FROM FINISHED FLOOR UNLESS , FINISH UNDERSIDE OF SOFFITS (WHERE THEY OCCUR) TO MATCH ADJACENT VERTICAL ON THE PROJECT, THE PRODUCT SELECTED SHALL BE COMPLETELY COMPATIBLE WITH OTHER NOTED OTHERWISE. SEE FINISH SCHEDULE. PRODUCTS PREVIOUSLY SELECTED EVEN IF THE PRODUCTS PREVIOUSLY SELECTED WERE ALSO THAT MATCH ADJACENT SURFACES TO THE FULLEST EXTENT POSSIBLE WITH REGARD TO 107 FINISH, U.O.N. VISUAL EFFECT. S VIOLATION OF NEW YORK 11. NOTIFY THE ARCHITECT IMMEDIATELY AND PRIOR TO PROGRESS OF WORK IF UNUSUAL FIELD 10. INSTALL ELECTRICAL SWITCH AND OUTLET COVER PLATES, SURFACE HARDWARE, ETC., WARNING CONTRACTORS OPTIONS. WHEREVER IN THE CONTRACT DOCUMENTS A PARTICULAR BRAND OR MAKE IT I A OF MATERIAL OR EQUIPMENT IS SHOWN OR SPECIFIED (AND WHETHER OR NOT WITH THE WORDS USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL OR SURPASS THAT OF EXISTING FGRE STATE EDUCATION LAW FOR ANY , CONDITIONS ARISE WHICH WOULD PREVENT THE CEILING AND/OR LIGHT FIXTURES FROM BEING AFTER PAINTING AND/OR APPLICATION OF WALL COVERINGS AND CARPET. PERSON, UNLESS ACTING UNDER THE DIRECTION AED INSTALLED AT THE INDICATED HEIGHT. "OR APPROVED EQUAL" (OR WORDS OF SIMILAR IMPACT), ANOTHER BRAND OR MAKE, WHICH IN MATERIALS. C9 „ � � PROFESSIONAL ENGINEER, TOTo 12. IN GENERAL, EXECUTE THE CEILING WORK TO PROVIDE A SMOOTH, CONTINUOUS, MATCHING, TIGHT 11. MODIFY EXISTING FLOOR SURFACES, TO RECEIVE NEW FLOORING MATERIALS TO PREVENT THE SOLE OPINION OF THE ARCHITECT IS EQUAL TO THAT SHOWN OR SPECIFIED, MAY BEALTER AN ITEM ON THIS DRAWING NOTICEABLE LUMPS AND DEPRESSIONS. SUBSTITUTED, BUT ONLY AFTER BEING SUBMITTED TO AND EXPRESSLY APPROVED IN WRITING BY BEFORE CUTTING EXISTING SURFACES, EXAMINE SURFACES TO BE CUT AND PATCHED AND IN ANY WAY. IF AN ITEM IS AND ALIGNING CEILING. THE FINAL CEILING INSTALLATION SHALL BE FREE OF VISUAL DEFECTS. * ,,rp. * ALTERED, THE ALTERING ENGINEER REPLACE CEILING TILES DAMAGED BY OTHER TRADES. 12. PARTITIONS AND MILLWORK TO RECEIVE STRAIGHT RESILIENT BASE OR CARPET, COVE THE ARCHITECT. NOTWITHSTANDING SUCH APPROVAL, HOWEVER, THE CONTRACTOR ASSUMES THE CONDITIONS UNDER WHICH CUTTING AND PATCHING IS TO BE PERFORMED. TAKE CORRECTIVE y SHALL AFFIX TO THE ITEM RESILIENT BASE AT RESILIENT FLOORING. U.O.N. RISK THAT SUCH BRAND OR MAKE IS NOT EQUAL TO THAT SHOWN OR SPECIFIED AND IF AT ANY ACTION BEFORE PROCEEDING. IF UNSAFE OR UNSATISFACTORY CONDITIONS ARE ENCOUNTERED, ,E. HIS/HER SEAL AND THE NOTATION 13 THE CEILING GRID SUSPENSION SYSTEM SHALL BE MANUFACTURED AND INSTALLED IN ACCORDANCE 272 Q *ALTERED BY' FOLLOWED BY 13. STAINED AND PAINTED SURFACES SHALL BE FINISHED SUCH THAT JOINTS ARE NOT TIME THE SUBSTITUTE APPEARS NOT TO BE SO EQUAL, THE CONTRACTOR SHALL REPLACE THE PROVIDE TEMPORARY SUPPORT OF WORK TO BE CUT. y4 HIS/HER SIGNATURE AND THE WITH THE MANUFACTURER'S STANDARD SPECIFICATIONS AND METHODS OF INSTALLATION. THE VISIBLE WHEN VIEWED FROM ANY REASONABLE ANGLE. SUBSTITUTE AT THE CONTRACTOR'S SOLE EXPENSE. F DATE OF SUCH ALTERATION AND A SUSPENDED CEILING BLACK IRON CARRYING CHANNELS SHALL BE SECURELY SUPPORTED BY PROTECT EXISTING CONSTRUCTION DURING CUTTING AND PATCHING TO PREVENT DAMAGE. NE SPECIFIC DESCRIPTION OF THE HANGERS FASTENED TO STRUCTURAL SUPPORTS AND PROPERLY SPACED TO SUPPORT LIGHTING 14. WALL COVERING SEAMS SHALL NOT TO OCCUR WITHIN 1 -0 OF CORNERS. APPLY ALTERATION. FABRIC SO WALL IS DIVIDED WITH A MINIMUM NUMBER OF SEAMS, AND WITH EQUAL 5. CONSTRUCTION CALLED FOR BY THE CONTRACT DRAWINGS MAY BE ADAPTED FOR A PARTICULAR PROVIDE PROTECTION FROM ADVERSE WEATHER CONDITIONS FOR PORTIONS OF THE PROJECT FIXTURES AND ACOUSTIC CEILING ASSEMBLY IN ACCORDANCE WITH N.Y.C.D.O.B. NEW CEILING WIDTH PANELS, U.O.N. BRAND OR MAKE OF MATERIAL OR EQUIPMENT. THEREFORE, IF ANY CONSTRUCTION NOT REQUIRED THAT MIGHT BE EXPOSED DURING CUTTING AND PATCHING OPERATIONS. DIFFUSERS AND AIR RETURN GRILLES, SHALL BE NATURED, ANODIZED, OR EXTRUDED ALUMINUM BY THE CONTRACT DRAW/INGS IN THEIR PRESENT FORM IS NECESSARY BECAUSE OF THE USE OF CONSULTANT: AND RECEIVE A BAKED ENAMEL WHITE FINISH. LIGHTING FIXTURES SHALL BE FASTENED TO THE 15. LOCATE INTERSECTIONS OF DIFFERENT FLOOR FINISH MATERIALS DIRECTLY UNDER AVOID INTERFERENCE WITH OWNER'S OPERATIONS IN ADJOINING AREAS OR INTERRUPTION OF 12-1 TECHNOLOGY DRIVE, CENTER OF DOORS, U.O.N. ANOTHER BRAND OR MAIKE OF MATERIAL OR EQUIPMENT, SUCH CONSTRUCTION SHALL BE FREE PASSAGE TO ADJOINING AREAS. TAKE ALL PRECAUTIONS NECESSARY TO AVOID CUTTING STRUCTURE ABOVE WITH SAFETY CHAINS INDEPENDENTLY OF THE CEILING SYSTEM. 16. SUBMIT CARPET SEAMING PLAN (FOR BROADLOOM) TO ARCHITECT PRIOR TO ORDERING FURNISHED OR PERFORNAED BY THE CONTRACTOR AT THE CONTRACTORS EXPENSE AND SUBJECT EXISTING PIPE, CONDUIT OR DUCTWORK SERVING THE BUILDING, BUT SCHEDULED TO BE SETAUKET,NY 11733 14. DO THE NECESSARY CUTTING FOR AND/OR BRIDGING REQUIRED FOR LIGHT FIXTURES, AIR AND AT LEAST (4) WEEKS PRIOR TO INSTALLATION FOR ARCHITECT'S REVIEW AND TO THE APPROVAL OF THE ARCHITECT. IN CASE OF DISCREPANCY BETWEEN A DESCRIPTION OR REMOVED OR RELOCATED, UNTIL PROVISIONS HAVE BEEN MADE TO BYPASS THEM. P. 631.689.8450 DIFFUSERS, ETC. REQUIREMENT IN THE CONTRACT DRAWING FOR ANY MATERIAL OR EQUIPMENT AND A CATALOG " ' r I; _..:` F. 631.689.8459 APPROVAL. NUMBER, OR OTHER DESIGNATION FOR THE SAME MATERIAL OR EQUIPMENT, (EVEN THOUGH CUT EXISTING CONSTRUCTION TO PROVIDE FOR INSTALLATION OF OTHER COMPONENTS OR ,� i www.wfcaia.com 15. INSTALL RESILIENT BASES STRAIGHT AND TRUE, TERMINATING THEM AGAINST OUTER EDGES OF 17. METAL DOORS, CONVECTOR COVERS, FRAMES AND WALLS AS SPECIFIED, TO RECEIVE A PERFORMANCE OF OTHER CONSTRUCTION ACTIVITIES, AND THE SUBSEQUENT FITTING AND STATED TO BE ACCEPTABLE), THE DESCRIPTION OR REQUIREMENTS SHALL CONTROL. , '.: :. DOOR FRAMES. FURNISH AND INSTALL RESILIENT BASE CORNER SECTIONS SHALL BE PROVIDED IN PAINT FINISH SHALL BE PAINTED AS FOLLOWS: PATCHING REQUIRED TO RESTORE SURFACES TO THEIR ORIGINAL CONDITION. LENGTHS NOT LESS THAN 1'-O" MEASURED FROM THE CORNER. GYPSUM: £ ,° ,; ; I T E C T S 16. COMPLETELY SEAL ABOVE CEILING PENETRATION CORES THROUGH FLOOR AND ROOF DECKS TO FIRST COAT: LATEX PRIMER 6• UNLESS SPECIFIC REQUIREMENT IS DEFINED FOR A SPECIFIC MANUFACTURER, IN THE INTEREST OF BYPASS UTILITY SERVICES SUCH AS PIPE OR CONDUIT, BEFORE CUTTING, WHERE SERVICES ARE MAINTAIN EXISTING FIRE RATINGS TYPICAL . UTILIZE "3M" FIRE-STOPPING PRODUCTS & SECOND COAT: LATEX EGGSHELL COMPETITION, THE DRAWINGS & SPECIFICATIONS ALLOW SELECTION FROM A VARIETY OF LISTED SHOWN OR REQUIRED TO BE REMOVED, RELOCATED, OR ABANDONED. CUTOFF PIPE OR CONDUIT ASSEMBLIES PRODUCT MANUFACTURES. THE SUBSTITUTIONS WILL BE CONSIDERED AS FOLLOWS: IN WALLS OR PARTITIONS TO BE REMOVED. CAP, VALVE OR PLUG AND SEAL THE REMAINING NO. DATE SUBMISSION 17. WHERE DUCTS OR PART OF DUCTS ARE RUNNING PARALLEL OVER FIRE RATED PARTITIONS, EXTEND THIRD COAT: LATEX EGGSHELL PORTION OF PIPE ON CONDUIT TO PREVENT ENTRANCE OF MOISTURE OR OTHER FOREIGN PARTITIONS AROUND DUCTS TO EFFECT COMPLETE FIRE RATED ASSEMBLES. METAL DOORS FRAMES: & CONVECTORS: MATTER AFTER BYPASSING AND CUTTING. 1 10/10/17 ISSUED FOR BID 18. WHERE DUCTS PENETRATE A FIRE RATED PARTITION AT AN ANGLE, SO THAT A FIRE DAMPER FIRST COAT: LATEX METAL PRIMER A.THE BIDDER SUBMIITS THE PROPOSED SUBSTITUTIONS TO Y IN AN ADDENDUM.THE ARCHITECT FOR REVIEW DURING THE 2 11/02/17 ISSUED FOR FILING CANNOT BE INSTALLED AT CENTERLINE OF RATED PARTITION, EXTEND A HOUSING FROM THE RATED SECOND COAT: LATEX SEMI GLOSS ENAMEL BIDDING PERIOD AND ARCHITECT INDICATES ACCEPTABILITY PATCH WITH DURABLE SEAMS AND MAKE THEM AS INVISIBLE AS POSSIBLE. RESTORE EXPOSED PARTITION TO THE FIRE DAMPER. COMPLETELY ENCLOSE THE DUCTS WITH MATERIAL EQUAL TO THIRD COAT: LATEX SEMI GLOSS ENAMEL FINISH OF PATCHED AREAS AND EXTEND FINISH RESTORATION INTO RETAINED ADJOINING THAT OF THE PARTITION FIRE RATING. COMPLETE PARTITION FIRE RATING SHALL BE MAINTAINED. B.THE PROPOSED ALTERNATE MANUFACTURER IS LISTED IN THE BID DOCUMENTS BY THE BIDDER AS CONSTRUCTION IN A MATTER THAT WILL ELIMINATE EVIDENCE OF PATCHING AND REFINISHING. 19. WHERE PIPES, CONDUITS OR LOW TENSION WIRING PENETRATE FIRE RATED OR SOUND RATED 18. PAINT SHALL BE LATEX - INTERIOR FINISHES TO COMPLY WITH LOCAL BUILDING CODE A "VOLUNTARY ALTERNATE" WHICH SHALL BE SUBJECT TO THE ARCHITECT REVIEW DURING THE BID ENCLOSURES SUCH AS WALL OR SLAB, THE SPACES AROUND SUCH PENETRATIONS SHALL NOT AND SHALL BE INTERIOR FINISH CLASS C FOR CORRIDORS AND ROOMS. ANALYSIS PERIOD. THE ARCHITECT SHALL BE ADVISED IN WRITING OF THIS PROPOSED WHERE REMOVAL OF WALLS OR PARTITIONS EXTENDS FROM FINISHED AREA INTO ANOTHER, EXCEED 1/2". PACK SPACES SOLID WITH MINERAL WOOL OR APPROVED EQUAL ON BOTH SIDES SUBSTITUTION. PATCH AND REPAIR FLOOR AND WALL SURFACES IN THE NEW SPACE TO PROVIDE AN EVEN OF THE RATED ENCLOSURE TO ENSURE FULL FIRE/SOUND RATING IN COMPLIANCE WITH THE 1g• INTERIOR FINISHES SHALL BE CLASSIFIED IN ACCORDANCE WITH SURFACE FLAME LOCAL BUILDING CODE. RATINGS. ALL FINISHES IN THE PROPOSED AREA TO BE INTERIOR FINISH CLASS B. C. THE CONTRACTOR HAS EXPERIENCE WITH THE SUBSTITUTED PRODUCT AS AN EQUIVALENT AND SURFACE OF UNIFORM COLOR AND APPEARANCE. REMOVE EXISTING FLOOR AND WALL FINISHES 20. FURNISH AND INSTALL 24 HOUR TEMPORARY LIGHTING INCLUDING TEMPORARY LIGHTING FOR FINISHES MATERIAL SHALL HAVE FLAME - SPREAD RATING OF 26 TO 75 SMOKE CAN DEMONSTRATE TO THE SATISFACTION OF THE ARCHITECT THAT IT IS IN FACT EQUIVALENCE IN AND REPLACE WITH NEW MATERIALS, IF NECESSARY, TO ACHIEVE UNIFORM COLOR AND INSTALLATION OR DELIVERY OF GOODS OR MATERIAL ON WEEKENDS. DEVELOPED RATING OF CLASS B. ALL KEY SPECIFICATION REQUIREMENTS. APPEARANCE. S OR ENLARGED PLANS ARE NOMINAL 20. ATTACHMENT AND ADHESIVES FOR INTERIOR LOCATIONS, WHICH WILL PRODUCE 7. THE BURDEN OF PROOF SHALL BE ON THE BIDDER TO DEMONSTRATE THE "EQUIVALENCE" OF THE 21. PARTITION THICKNESS SHOWN ON CONSTRUCTION PLAN (S) PRODUCTS MORE TOXIC THAN THOSE GIVEN OFF BY WOOD OR PAPER WHEN PROPOSED SUBSTITUTION. DIMENSIONS. PARTITIONS ARE DIMENSIONED FROM FINISH FACE OF GYPSUM BOARD TO FINISH DECOMPOSING OR BURNING WILL BE REJECTED. FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. SEE PARTITION TYPE DETAIL FOR ACTUAL 21. STEEL STUD AND GYPSUM WALLBOARD PARTITIONS DIMENSIONS. A.STEEL STUDS SHALL BE ROLL FORMED CHANNEL TYPE SECTIONS FABRICATED OFDELIVERY STORAGE AND HANDLING EGRESS NOTES 22. ALIGN AND SAND SMOOTH GYPSUM BOARD SURFACES. GALVANIZED SHEET STEEL, SIZE PER PLANS AND IN THE LONGEST LENGTHS AVAILABLE 23, WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE AND TRUE AND IN PROPER SO THAT THE STUDS EXTEND VERTICALLY, IN ONE PIECE, FROM FLOOR TO CEILING KEY PLAN: AND/OR BEAMS AND/OR DECKS ABOVE ALIGNMENT. 1. DELIVER, STORE AND HANDLE PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S MAINTAIN LEGAL EXIT AISLES FOR SPACES BEING INTERRUPTED BY CONSTRUCTION. PROVIDE 24. FULLY PACK AND SEAL EXISTING AND NEW FLOOR PENETRATIONS FOR PIPING IN ACCORDANCE B.CEILING AND FLOOR RUNNERS SHALL BE ROLL FORMED CHANNEL TYPE SECTIONS RECOMMENDATIONS, USING MEANS AND METHODS THAT WILL PREVENT DAMAGE, DETERIORATION 60" MAIN AISLES AND A MIN. OF 44" SECONDARY AISLES FOR EMPLOYEES TO EXIT SPACE IN WITH THE GOVERNING BUILDING LAWS. FABRICATED OF USS NO. 25 GAUGE, GALVANIZED SHEET STEEL, RUNNERS SHALL BE IN AND LOSS, INCLUDING THEFT. 10 -0 LENGTHS. CASE OF AN EMERGENCY. AISLES SHALL MAINTAIN AISLES FREE AND CLEAR FROM 25. ARRANGE FOR USE OF FREIGHT ELEVATORS WITH THE BUILDING PROPERTY MANAGER FOR THEC.GYPSUM WALLBOARD SHALL BE GRADE "X" FIRE - RETARDANT WALLBOARD 48 INCHES 2• CONTROL DELIVERY SCHEDULES TO MINIMIZE LONG-TERM STORAGE AT THE SITE AND PREVENT OBSTRUCTION. PROVIDE TEMPORARY EXIT DIAGRAMS, CLEARLY LEGIBLE, MOUNTED IN DURATION OF THIS PROJECT. PROVIDE PROTECTION FOR THESE ELEVATORS WHILE IN USE. WIDE AND OF THICKNESS INDICATED ON THE CONTRACT DRAWINGS AND SHALL BE OF OVERCROWDING OF CONSTRUCTION SPACES. IN PARTICULAR, COORDINATE DELIVERY AND CONSPICUOUS LOCATIONS FOR ALL TO SEE. INSTALLATION 26. FIELD CONDITIONS MAY REQUIRE MODIFICATIONS IN THE DETAILS OF THE DRAWINGS AND UNIFORM QUALITY CONFORMING TO FEDERAL SPECIFICATION 55-L-30 AND TO ASTM 4 QUANTITIES OF WORK INVOLVED. THE WORK SHALL BE CARRIED OUT TO MEET THESE FIELD C56. RECOGNIZED TOO INSURE MINIMUM HOLDING OF STORAGE TIMES FOR ITEMS KNOWN OR BE FLAMMABLE, HAZARDOUS, EASILY DAMAGED, OR SENSITIVE TO DETERIORATION, MAINTAIN EXIT AND EMERGENCY LIGHTING FOR ADJACENT OCCUPIED OR TENANT SPACES DURING THEFT AND THEIR SOURCES OF LOSS. THE COURSE OF CONSTRUCTION. SHOULD ANY OF THESE SYSTEMS REQUIRE SHUTDOWN, NOTIFY I ' CONDITIONS IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. WALLBOARD SHALL BE FURNISHED AND INSTALLED IN THE LONGEST AVAILABLE LENGTHS THE VERIZON PROJECT MANAGER, IN WRITING, WITH 72 HOUR NOTICE. - _ I - "•` 27. REMOVE MISCELLANEOUS APPURTENANCES, ETC., ON EXISTING WALLS WHICH ARE NOT TO BE SO THAT WALLBOARD PANELS EXTEND VERTICALLY IN ONE PIECE FROM FLOOR TO 3. DELIVER PRODUCTS TO THE SITE IN THE MANUFACTURERS SEALED CONTAINER OR OTHER USED FOR NEW ALTERATIONS, AS DIRECTED BY VERIZON PROGRAM MANAGERS. PATCH WALLS THAT CEILING AND-OR GLASS, BEAMS OR DECKS ABOVE. PACKAGING SYSTEM, COMPLETE WITH LABELS AND INSTRUCTIONS OR HANDLING, STORING, ARE INDICATED TO RECEIVE NEW FINISHES. DELIVER FIRE RATED GYPSUM BOARD TO THE CONSTRUCTION SITE BEARING UNPACKING, PROTECTING; AND INSTALLING. HE SITE IN A MANNER THAT WILL FACILITATE INSPECTION AND 28. NEW WALLS AND PARTITIONS, WITHIN AREA OF WORK SHALL RECEIVE A PRIMER AND [2] FINISH UNDERWRITERS LABORATORY CERTIFICATION. 4. STORE PRODUCTS AT T COATS OF AN EGGSHELL FINISH PAINT. INTERIOR TRIM (DOORS, FRAMES, ETC.) SHALL RECEIVE A D. SOUND ATTENUATION BLANKETS SHALL BE COMPRESSIBLE MINERAL FIBER MEASUREMENT OF QUANITITY OR COUNTING OF UNITS. PRIMER AND [2] FINISH COATS OF A SEMI-GLOSS FINISH PAINT. COLORS WILL BE SELECTED BY ("THERMAFIBER" AS MANUFACTURED BY US GYPSUM CO. OR APPROVED EQUAL). 5. STORE HEAVY MATERIALS AWAY FROM THE PROJECT STRUCTURE IN A MANNER THAT WILL NOT r =" THE ARCHITECT. ENDANGER THE SUPPORTING CONSTRUCTION. 29. FURNISH AND INSTALL TEMPORARY (TP) / DUST (DP) PROTECTION REQUIREMENTS INDICATED ON E. JOINT TREATMENT PRODUCTS SHALL CONFORM TO ASTM C-474 AND C- 475. TAPING DRAWINGS, AS DIRECTED BY THE VERIZON REPRESENTATIVE AND PER GENERAL VERIZON AND SPACKLING SHALL BE A THREE (3) COAT 476. APPLICATION. ARM OF WORK rg� PRACTICES. 'DP' PROTECTION SHALL CONSIST OF FULL HEIGHT, 6 MIL FIRE RETARDANT, F. SCREWS FOR FASTENING WALLBOARD TO STUDS SHALL BE BUGLE TYPE PHILIPS HEAD ABBREVIATIONS & SYMBOL LEGEND ANTI-STATIC PLASTIC BY REBCO, OR EQUAL. 'TP' PROTECTION SHALL BE 8'-0" H. TEMPERED SCREWS, SPECIFICALLY MANUFACTURED FOR POWER TOOL INSTALLATION. MASONITE ON FIRE RETARDANT WOOD OR METAL STUD, 24" O.C. WITH PLASTIC DUST PROTECTION G. CORNER BEADS SHALL BE BUR - A - BEAD USG CORNER REINFORCEMENT; OR A/C AIR CONDITIONING DN DOWN LAM LAMINATE (D) TEL TELEPHONE FROM TOP OF MASONITE TO UNDERSIDE OF CEILING. ALL PROTECTION SHALL BE SEALED TIGHT APPROVED EQUAL. AC ACOUSTICAL DP DAMP PROOFING LAV LAVATORY T 0 TOP OF T.O.S. (TOP AT EDGES. OVERLAP EDGES OF ACCESS OPENINGS IN PLASTIC PROTECTION 18" MIN. ACCESS H,TRIM MEMBERS SHALL BE FABRICATED OF USS NO 25 GAUGE GALVANIZED STEEL AND ACC ACCESS DR DOOR LL LIVELOAD OF STEEL) _ _ _ _ _ _ EXISTING PARTITION OPENINGS IN 'TP' PROTECTION SHALL BE FUNCTIONAL 3' x 7' HINGED DOORS. PROTECTION IN SHALL INCLUDE CORNER REINFORCEMENT AND CASING TYPE EDGE TRIM. CORNER AND ACP ACOUSTICAL PANEL DS DOWNSPOUT LP LOW POINT TYP TYPICAL - - - - - - TO BE REMOVED 1 SECTION USE DURING ALTERATIONS SHALL BE SEALED AND MAINTAINED FOR MAXIMUM DUST CONTROL. EDGE TRIM MEMBERS SHALL BE IN SINGLE LENGTHS. ACT ACOUSTICAL TILE DTL DETAIL MAX MAXIMUM UON UNLESS OTHERWISE A-1 MARKER 22. THOROUGHLY PATCH, CLEAN, AND PREPARE EXISTING PAINTED WALL SURFACES FOR ADD ADDENDUM DWG DRAWING MATL MATERIAL NOTED = NEW PARTITION 30. ELEVATION 0'-0" IS A REFERENCE OF TIHE EXISTING FINISHED FLOOR HEIGHT. NOTATION TO APPLICATION OF NEW FINISH PAINT (2 COATS MIN.). SUBMIT SAMPLES TO THE ADJ ADJACENT DWR DRAWER MECH MECHANICAL VCT VINYL COMPOSITE TILE (FULL HEIGHT) gg HEIGHTS WILL BE FROM THIS ELEVATION, UNLESS OTHERWISE NOTED. SURFACES ABOVE RAISED E EAST MFR D ARCHITECT FOR APPROVAL. AFF ABOVE FINISH FLOOR ( ) MANUFACTURE (R) (D) VDT VIDEO DISPLAY TERM. NEW RATED (KI, TZ:co FLOOR ARE TAKEN FROM FINISHED RAISED FLOOR HEIGHT AND NOTED (A.R.F.). 23, TAPE AND SAND SMOOTH GYPSUM BOARD SO JOINTS ARE NOT VISIBLE. PATCH AND ALT ALTERNATE EA EACH MIN MINIMUM VIF VERIFY IN FIELD PARTITION q-1 ELEVATION INDICATOR 31. ROOM NUMBERS ARE FOR REFERENCE TO THIS ALTERATION DURING CONSTRUCTION, ONLY. REPAIR SURFACES TO MATCH ADJACENT OR ADJOINING SURFACES WHERE DAMAGED OR ALUM ALUMINUM ELEC ELECTRIC (AL) MIR MIRROR W WEST 32. PERFORM ANY WORK PRODUCING EXCESSIVE NOISE DURING OFF-HOURS. (I.E. CORE•• DRILLING, DISTURBED BY NEW WORK. ARCH ARCHITECT (URAL) ELEV ELEVATION MO MASONRY OPENING W/ WITH NEW PARTITION 24. PATCH EXISTING WALLS WITHIN WORK AREA WHICH ARE SCHEDULED TO BE PAINTED SO ARF ABOVE RAISED FLOOR EMERG EMERGENCY MTL METAL (REDUCED HEIGHT) JACK HAMMERING, EXCESSIVE BANGING, ETC...) EXPLOSIVE OR POWER DRIVE SHOT DEVICES AS TO OBTAIN A SMOOTH TRANSITION WITH ADJACENT SURFACES AND SO AS TO BE BD BOARD ENCL ENCLOSE (ENCLOSURE) N NORTH WB WALL BASE ® SUPPLY SHALL NOT BE USED. SUITABLE TO RECEIVE NEW PAINT FINISHES. BLDG BUILDING EQ EQUAL NIC NOT IN CONTRACT WD WOOD EXISTING PARTITION 33, VERIZON WILL REMOVE HAZARDOUS MATERIALS, INCLUDING ASBESTOS CONTAINING MATERIAL(S) EW EACH WAY NO NUMBER WM WIRE MESH TO REMAIN RETURN A/C REPLACEMENT ENCOUNTERED THROUGHOUT. IF EXISTING ASBESTOS CONTAINING MATERIAL IS ENCOUNTERED 25. NEW WALLS AND PARTITIONS AND EXISTING WALLS AND PARTITIONS ADJACENT TO NEW BO BLOCK NOM NOMINAL DURING THE WORK, REPORT THIS IMMEDIATELY TO THE VERIZON PROGRAM MANAGER FOR FLOORING SHALL RECEIVE NEW 4" HIGH RUBBER BASE (BOTH SIDES UNLESS BO BOTTOM OF EWC ELECTRIC WATER COOLER W/0 WITHOUT EXISTING DOOR TO FOR CARRIER SWRM WP WATERPROOFING •� � BRG BEARING EXC EXCAVATE NTS NOT TO SCALE � REMEDIATION. CONTRACTOR SHALL REMOVE ALL OTHER EXISTING FLOORINGS TO THE SLAB AS OTHERWISE NOTED). EXH EXHAUST OA OVERALL WWM WELDED WIRE MESHREMAIN ® SECURITY NOTED ON PLANS; PATCH VOIDS IN SLABS THAT ARE TO RECEIVE NEW FLOORING. BIRK BSMT BRICK EMENT EXIST EXISTING OC ON CENTER WWF WELDED WIRE FABRIC /� CAMERA EJ EXPANSION JOINT OH OVERHEAD � � EXISTING DOOR/WALL BUR BUILT UP ROOFING SMOKE DETECTOR 34. SEAL PENETRATIONS THROUGH EXISTING/'NEW FIRE-RATED WALLS, CEILINGS, ETC. WITH WORK TIME DESIGNATIONS OPNG OPENING TO BE REMOVED s CAB CABINET EXT EXTERIOR VERIZON-APPROVED '3M' FIRE-STOPING PRODUCTS. FIRE-STOPPING PERIMETER OF DUCT / CB CATCH BASIN FD FLOOR DRAIN PC OPPOSITE SPRINKLER HEAD, REFER 31755 MAIN RD. CONDUIT PENETRATIONS. REFER TO DETAILS FOR ADDITIONAL INFORMATION. CBIC CABLE HOLE IN CEILING FDN FOUNDATION PC POURED CONCRETE 81 NEW DOOR • FIRE PROTECTION DRAWING 35. SUBSEQUENT TO FILING WITH THE DEPARTMENT OF BUILDING, THE ARCHITECT REQUIRES NEW SHALL BE THE WORK TIME SCHEDULES OF OPERATIONS IN VARIOUS CBIF CABLE HOLE IN FLOOR FE FIRE EXTINGUISHER PL PLATE � C (SEE SCHEDULE) O FOR MORE INFORMATION CUTCHOGUE, NY THE FOLLOWINGPL LAM PLASTIC LAMINATE TR-1'S FOR WITHDRAWAL OF APPLICANT. INSPECTIONS, TESTS AND OTHER DIRECTIVE 14 AREAS WITHIN A VERIZON CENTRAL OFFICE FACILITY: CEM CEMENT FIN FINISH (ED) GROUND FLOOR REQUIREMENTS ARE THE RESPONSIBILITY OF THE CONSTRUCTION MANAGER AND/OR INDIVIDUAL CCN CLOSED CIRCUIT T..V. FIXT FIXTURE PNL PANEL PTN PARTITION Q NEW LIGHT FIXTURE ILLUMINATED EMERGENCY TRADE. . REGULAR OR STANDARD TIME HOURS OF CONSTRUCTION OPERATIONS SHALL BE CI CAST IRON FPEXIT SIGN. R FLOOR (ING) 4� TITLE: 36. LARGE SCALE DRAWINGS TAKE PRECEDENT OVER SMALL SCALE DRAWINGS. DETAIL DRAWINGS TAKE PERFORMED BETWEEN THE HOURS OF 7:00 AM TO 5:00 PM, MONDAY THROUGH FRIDAY CL CENTER LINE FIREPROOF PVC POLYVINYL CHLORIDE CLO CEILING FPSC FIREPROOF SELF-CLOSING R RISER CLO CLOSET PRECEDENT OVER LARGE AND SMALL SCALE DRAWINGS. (EXCEPT HOLIDAYS) FTFEET RA RAISED ACCESS C1 CONSTRUCTION NOTE TAG GENERAL NOTES 37. IN THE EVENT OF A DISCREPANCY BETWEEN DRAWINGS AND SPECIFICATIONS OR BETWEEN • 'PREMIUM„ OR OUT-OF-HOURS" TIME HOURS OF CONSTRUCTION OPERATIONS SHALL FTG FOOTING RAD RADIUS Zt WORKING POINT FOR CLU CLEAR TE(ANMA GA GAGE GAUGE D4 REMOVAL NOTE TAG DRAWINGS BRING THE DISCREPANCY TO THE ARCHITECT'S ATTENTION IMMEDIATELY, IN WRITING, FOR BE PERFORMED BETWEEN THE HOURS OF 6:00 PM TO 7:00 AM, MONDAY THROUGH RD ROOF DRAIN � AND ABBREVIATIONS CMU CONCRETE MASONRY � ACT CEILING WORK CLARIFICATION. THE GREATER MONETARY VALUE SHALL TAKE PRECEDENCE IN THE EVENT THE FRIDAY, WEEKENDS AND HOLIDAYS. GC GENERAL CONTRACT OR REF REFERENCE CONTRACTOR NEGLECTS TO OBTAIN CLARIFICATION. 0 " CNTR COUNTER ( ) REFG REFRIGERATOR SAFE TIME HOURS OF CONSTRUCTION OPERATIONS SHALL BE PERFORMED BETWEEN COL COLUMN GFI GROUND FAULT INTERRUPT REINF REINFORCED � EXISTING FIRE � PARTITION TYPE TAG DATE: 8/16/17 THE HOURS OF 11:00 PM TO 7:00 AM, MONDAY THROUGH FRIDAY, WEEKENDS AND CONC CONCRETE GL GLASS GLAZING EFEC EXTINGUISHER 38. THE CONTRACTOR SHALL TAKE NO ADVANTAGE OF ANY APPARENT ERROR OR OMISSION IN THE HOLIDAYS. GWB GYPSUM BOARD WALL RES RESILIENT CONTRACT DOCUMENTS. IN THE EVENT THE CONTRACTOR DISCOVERS SUCH AN ERROR, OR CONST CONSTRUCTION RFG ROOFING CABINET LOCATION QQ DOOR TAG PROJECT NO: 17-2165 OMISSION IN THE CONTRACT DOCUMENTS, HE SHALL IMMEDIATELY NOTIFY THE ARCHITECT. THE • "WEEKEND" HOURS OF CONSTRUCTION OPERATIONS SHALL BE PERFORMED BETWEEN COR R CONTRACT (OR) HC HOLLOW CORE RM ROOM DRAWN BY: JPK CORR CORRIDOR HDR HEADER ANEW FIRE • ARCHITECT WILL THEN MAKE SUCH CORRECTIONS AND INTERPRETATIONS AS MAY BE DEEMED THE HOURS OF 6:00 PM ON FRIDAY TO 6:00 AM ON MONDAY. RO ROUGH OPENING ,s NECESSARY FOR FULFILLING THE INTENT OF THE CONTRACT DOCUMENTS. CPT CARPET HDW HARDWARE FEC EXTINGUISHER CHECKED BY: EWS HGT HEIGHT S SOUTH CEILING HEIGHT 39. VERIFY FIELD CONDITIONS AND NECESSARY DIMENSIONS PRIOR TO BEGINNING WORK AT THIS SITE WORK SHALL BE PERFORMED IN ACCORDANCE WITH VERIZON STANDARDS AND IN CT CERAMIC TILE HM HOLLOW METAL SCW SOLID CORE WOOD DOOR CABINET LOCATION DATUM SCALE: AS NOTED AND REPORT DISCREPANCIES TO THE ARCHITECT FOR CLARIFICATION AND AMENDMENT. ACCORDANCE WITH THE VERIZON NETWORK OPERATIONS MANUAL (FOR ACTIVITY WITHIN A CTR CENTER HP HIGH POINT SD STORM DRAIN CENTRAL OFFICE LOCATION). PREPARE AN "MOP" OR METHOD OF PROCEDURE FOR THIS DEMO DEMOLITION HTG HEATING SECT SECTION NEW 2'X2' DP DUST PROTECTION DRAWING NO: 40. CONTRACTOR SHALL BE RESPONSIBLE FOR DOCUMENTING EXISTING CONDITIONS PRIOR TO START PROJECT AT THE INCEPTION OF WORK IF DEEMED NECESSARY BY THE FACILITY DEPT DEPARTMENT SF SQUARE FOOT CEILING GRID HVAC HEATING VENTILATION TEMPORARY OF WORK. DOCUMENTATION SHALL BE IN THE FORM OF ELECTRONIC PHOTOGRAPHS AND WRITTEN MANAGER AND NETWORK OPERATIONS MANAGER. DF DRINKING FOUNTAIN & AIR CONDITIONING SIM SIMILAR TP PROTECTION DESCRIPTION OF EXISTING DAMAGED ITEMIS, NOT SPECIFICALLY NOTED ON CONSTRUCTION DIA DIAMETER SPEC SPECIFICATION DRAWINGS. PROVIDE COPIES OF THIS DOCUMENTATION TO THE ARCHITECT & VERIZON PROPERTY DIAG DIAGONAL IG ISOLATED GROUND SPR SPRINKLER ROOM I = 00 000 MANAGER AT START OF WORK. DAMAGED ITEMS, NOT SPECIFICALLY NOTED OR VISUALLY OBSERVED DIM DIMENSION IN INCH SQ SQUARE Q ROOM TAG } REFERENCE DATUM IN PHOTOGRAPHS, SHALL BECOME THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL DIV DIVISION INSUL INSULATION (D) (ION) STD STANDARD SHEET NO: 1 OF 7 REMOVE, REPAIR AND/OR REPLACE AT THEIR OWN EXPENSE. DL DEAD LOAD JC JANITOR'S CLOSET STL STEEL SUSP SUSPENDED - - - - -- -- --- F-_1 F-_1 Lp PDSC WORK BENCH L ❑ + LP PDSC WORK BENCH L— ❑ + to 1oo.ot cn r4 1a '°°°DC POWER ROOM ❑ ❑ SCOPE �" [)C POWER ROOM v 1 0 ❑ ❑ SCOPE Cl a� 0 0 110 DPC� COMP. DEHY ROOM R M 110 COMP. DENY ROOM R M U M o� ® 109 108 a ® 109 108 48V BATA & B 48V BAT A & B EMR POWERSAFE G 2T2R POWERSAFE G Cl w B to AL.M PDSC 13 (" w� ALM PDSC COGB I I " PNL 0101 COGB rr- — �` PNL 0101 FE + + U. — + + + — 5ESS DIG. SW. � _ 5ESS DIG. SW. = D .. - o m � _D m _ ° w Jacobsen & Horan zF1 0 I EA z w a En ineerin , P.C. w g 9 990 South 2nd Street M 71 Ronkonkoma, NY 11779 T-H w T-H w 0 O: (631) 580-6100 RCDR F N II (I + Q R CDR�� (I O II + Q F. (631) 580-6101 D7 O O www.jhepc.com D3 z HW � C2 C2 O TP3 BOILER 8 z Ei�n, IT IS WARNING:IOLATION OF NEW YORK BOILER �_ ILER a �R D Aq PERSONSTATE , UNLESS CUCATION TINGOR ANY UN ER Fp RM Q RM , PROFESSIONAL ENGINEER, TO � D11 2 _ / C1 � Q \� �P BERT / THE DIRECTION OF A LICENSED y �'� IN ANY WAY.TER AN E F AN IM ON TTEM HIIS DRAWING - 106 I -- 106 ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM 5ESS 5ESS TOLL �' 5ESS 5ESS/TOLL "' �, HIS/HER SEAL AND THE NOTATION ALTERED BY" FOLLOWED BY MTCE. CTR. STOR ROOM -- pp-PA Qo MTCE. CTR. STOREROOM -- PP-PA OF 1 y DATHIS/HER EHOF SUCH TALTERATION ANDHE A 112 113 112 113 M NE SPECIFIC DESCRIPTION OF THE ALTERATION. 1 CONSULTANT: az II 3 12-1 TECHNOLOGY DRIVE, TP3 — — — —� Li L a I C2 C2 P-1 P-4 '` A-50 SETAUKET, NY 1173.3 W - P. 631.689.8450 �,v CARRIER EQPT. I D4 D5 I a C1 P-2 P-5 Fr g D8 _ _ _ y I �n CARRIER EQPT. LO TOLL ADMN " TOLL ADMN /�`�. F. 631.6aia.co 9 w a w { 115 115 P-3 P-s www.wfcaia.com ..,. I m 114 a - - - � I a 1 F 114 a LJ' 0 m [� C� === == - L 0 m0 [� _ 3 . ` '' I T E C T S D6 II a MIXED AIR PLENUM —50 m r NO. DATE SUBMISSION LOCKER & LOCKER & 1 10/10/17 ISSUED FOR BID + ® + LOUNGE 1 - + + ® + LOUNGE Cl — 2 11/02/17 ISSUED FOR FILING 104 m � � � 104 Cl — D1 D2 L ENTRY C2 L C2 ENTRY 101 — 0 0 o � TOILET D TOI ET 0 MDF 0 pQ 102 MDF pQ 102 I 116 D3 116 ()O JAN CLS DO JAN CLS 103 _11= 103 KEY PLAN: I i . • I i it REMOVAL SCHEDULE CONSTRUCTION SCHEDULE RTHE GENERAL CONTRACTOR SHALL COORDINATE ALL WALL, CEILING AND FLOOR PENETRATIONS WITH ALL TRADE CONTRACTORS, PROVIDE NECESSARY PROTECTION, D1 THE CONTRACTOR SHALL PATCH ALL AREAS AFFECTED BY DUCT INSTALLATION/REMOVAL TO MATCH ADJACENT SURROUNDING CONSTRUCTION AND FINISH IN ALL ASPECTS, SEAL ALL C1 PATCHING, PAINTING AND FIRESTOPPING AS REQUIRED BY THESE ALTERATIONS WHETHER THE RESULT OF NEW WORK, MODIFICATIONS TO EXISTING OR REMOVALS. PENETRATIONS THROUGH WALLS WITH VERIZON — APPROVED 'HILTI OR 3M' FIRESTOP PRODUCTS. REFER TO ARCHITECTURAL DETAILS ON A-501. I u I SHADED AREA INDICATES TO PROVIDE AND INSTALL J" FIRE RETARDANT TEMPERED (BOTH SIDES) MASONITE FLOOR PROTECTION THROUGHOUT AREAS OF CIRCULATION AND C2 ALL EXISTING WALL, CEILING AND COLUMN SURFACES AFFECTED BY CONSTRUCTION SHALL BE REPAIRED WITHIN THE ALTERATION AREAS. PAINT TO MATCH EXISTING ADJACENT COLOR AS f, CONSTRUCTION. PROTECTION SHALL BE INSTALLED THROUGHOUT ALL CORRIDORS ACCESSED FOR DELIVERIES AND DEBRIS REMOVALS. ALL FLOOR PROTECTION SHALL HAVE CLOSE AS PRACTICAL. D2 SEALED TAPED SEAMS AND BE MAINTAINED THROUGHOUT CONSTRUCTION. CONTRACTOR SHALL REMOVE AT PROJECT COMPLETION. ALL RESIDUAL TAPE TO BE REMOVED FROM FLOORING. I i. CONTRACTOR TO PROVIDE AND INSTALL ALL TEMPORARY PROTECTION OF TELCO NETWORK EQUIPMENT AS INDICATED ON PLAN. REFER TO PROTECTION TYPE AS INDICATED AREA OF WORK D3 ON PLAN AND PER PIROTECTION DETAILS ON SHEET 7/A-501. CONTRACTOR TO PROVIDE A COORDINATION AND PHASING PLAN WITH MECHANICAL CONTRACTOR PRIOR TO FINISH SCHEDULE ANY NETWORK AREA PROTECTION FOR MAINTAINING TEMPORARY COOLING TO TELCO EQUIPMENT. ALL PHASING PLANS SHALL BE REVIEWED WITH VERIZON NETWORK ENGINEERING FOR APPROVAL. COORDINATE WITH MECHANICAL AND ELECTRICAL CONTRACTOR FOR THE REMOVAL OF ALL HVAC EQUIPMENT AND ASSOCIATED ELECTRICAL COMPONENTS, DUCT WORK ETC. P-1 GYP. BD. OR MASONRY WALLS: INSTALL ONE COAT OF SHERWIN WILLIAMS PRO—MAR 200 ZERO VOC PRIMER AND TWO COATS BENJAMIN MOORE ECO SPEC WB D4 REFER TO ENGINEERINIG DRAWINGS FOR MORE INFO AND FOR TEMPORARY SPOT COOLING NOTES. GC TO PATCH AND PRIME ALL AREAS FROM REMOVALS IN PREPARATION INTERIOR LATEX EGG SHELL FINISH 373 COLOR : TO MATCH EXISTING ADJACENT PAINT. FOR NEW PAINT. SCRAPE FLOOR SLAB AND CONCRETE PAD FREE OF LOOSE & SCALING PAINT FOR PREPARATION OF NEW PAINTED FLOOR FINISH. REMOVE ANY MISC. APPURTENANCES AS DOORS AND BUCKS: INSTALL ONE COAT OF SHERWIN WILLIAMS PRO INDUSTRIAL PRO—CRYL UNIVERSAL PRIMER, 866-310 SERIES, AND TWO COATS SHERWIN WILLIAMS D5 REQUIRED. P-2 PAINT, PROMAR 200 INTERIOR LATEX SEMI—GLOSS FINISH , COLOR: TO MATCH EXISTING ADJACENT PAINT. . D6 EXISTING FRESH AIR LOUVER TO REMAIN. INSTALL INSULATED PANEL, FURNISHED BY MC. REFER TO INSULATED PANEL DETAIL ON 3/A-502. CEILING: INSTALL ONE COAT OF SHERWIN WILLIAMS PRO INDUSTRIAL PRO—CRYL UNIVERSAL PRIMER, B66-310 SERIES, AND TWO COATS BENJAMIN MOORE ECO SPEC WB D7 PROTECT BOILER AND HOT WATER HEATER FOR DURATION OF PROJECT. P-3 INTERIOR LATEX FLAT FINISH 373 COLOR : TO MATCH EXISTING ADJACENT PAINT. CAREFULLY PROVIDE OPENING IN EXISTING GYP. WALL TO ACCOMMODATE 16x12 RETURN DUCT, PATCH AND REPAIR ALL PENETRATIONS TO MATCH ADJACENT FINISHES IN D8 ALL ASPECTS. REFER TO ENGINEERING DRAWINGS FOR ROUTING AND MORE INFO. P_4 FLOOR AND CONCRETE PAD: PRIME WITH ONE COAT SHERWIN WILLIAMS ARMOR SEAL FLOOR—PLEX 7100 PRIMER, AND TWO COATS OF SHERWIN WILLIAMS ARMOR SEAL FLOOR—PLEX 7100 FINISH. COLOR: GREY A/C REPLACEMENT ENETRATIONS Dg TOEFULLY MATCH ADJACIDE ENT OFINISHESING IN ALLTING ASP CTS MASONRY REF RA ACCOMMODATE TO LOOSE LINTEL SCHEDULE AND RFIREUCT STOPPING IDE ALL DETAILSR ONU1RED 5/A-502EAND PATCH ENGINEERING RREPAIR DRAW NGS FOR ROUTING FOR CARRIER SWRM AND MORE INFO. P-5 PAINT SAFETY STRIPE ON PAD. VERTICAL AND 4" HORIZONTAL SURFACES OF CONCRETE OSHA "SAFETY YELLOW" CAREFULLY PROVIDE OPENING IN EXISTING MASONRY WALL TO ACCOMMODATE 16x16 RETURN DUCT PROVIDE ALL REQUIRED LINTELS, PATCH AND REPAIR ALL PENETRATIONS 10 TO MATCH ADJACENT FINISHES IN ALL ASPECTS. REFER TO LOOSE LINTEL SCHEDULE AND FIRE STOPPING DETAILS ON 5/A-502 AND ENGINEERING DRAWINGS FOR ROUTING PAINT EXTERIOR LOUVER: INSTALL ONE COAT OF PRIMER AND TWO COATS OF EXTERIOR PAINT COMPATIBLE WITH LOUVER MATERIAL TO MATCH EXISTING ADJACENT El AND MORE INFO. P—g SURFACES. 31755 MAIN RD. CAREFULLY PREPARE (ENLARGED OPENING IN EXISTING MASONRY WALL FROM 42x20 DUCT TO ACCOMMODATE NEW 52x24 SUPPLY DUCT PROVIDE ALL REQUIRED LINTELS, CUTCHOGUE, NY D11 PATCH AND REPAIR ALL PENETRATIONS TO MATCH ADJACENT FINISHES IN ALL ASPECTS. REFER TO LOOSE LINTEL SCHEDULE AND FIRE STOPPING DETAILS ON 5/A-502 GROUND FLOOR AND ENGINEERING DRAWINGS FOR ROUTING AND MORE INFO. 1 — CONTRACTOR SHALL SUBMIT SAMPLES OF ALL FINISHES TO ARCHITECT FOR REVIEW AND APPROVAL, AND FOR COMPARISON TO EXISTING FINISHES, PRIOR TO ORDERING ANY MATERIAL. IF NEW MATERIALS ARE SCRAPE, SAND AND CLEAN EXISTING LOUVER PRIME AND REPAINT TO MATCH ADJACENT COLOR AND FINISH IN ALL ASPECTS. TYP. BOTH LOUVERS. NO LONGER AVAILABLE, THE CONTRACTOR SHALL, AT NO COST TO THE OWNER, FURNISH AND INSTALL A FINISH OF COMPARABLE VALUE, AS SELECTED BY THE ARCHITECT. TITLE: CAREFULLY REMOVE EXISTING TRANSFER GRILLE, PATCH AND REPAIR TO MATCH ADJACENT FINISHES IN ALL ASPECTS. REFER TO ENGINEERING DRAWINGS FOR MORE INFO. GROUND FLOOR REMOVAL CAREFULLY PROVIDE OPENING IN EXISTING WALL FOR NEW TRANSFER GRILLE PATCH AND REPAIR TO MATCH ADJACENT FINISHES IN ALL ASPECTS. REFER TO ENGINEERING AND CONSTRUCTION PLAN DRAWINGS FOR MORE INFO. DATE: 8/16/17 CAREFULLY PROVIDE OPENING IN EXISTING MASONRY WALL TO ACCOMMODATE 16x10 EXHAUST FAN PROVIDE ALL REQUIRED LINTELS, PATCH AND REPAIR ALL PENETRATIONS 15 TO MATCH ADJACENT (FINISHES IN ALL ASPECTS. REFER TO LOOSE LINTEL SCHEDULE AND FIRE STOPPING DETAILS ON 5/A-502 AND ENGINEERING DRAWINGS FOR MORE PROJECT NO: 17-2165 R INFO. DRAWN BY: JPK CHECKED BY: EWS SCALE: AS NOTED DRAWING NO: FLOOR PROTECTION NOTE: O' 4' 8' 16' o' 4' 8' 16' SHADED AREAS INDICATE AREAS OF FLOOR 1 GROUND FLOOR REMOVAL PLAN, AND/OR NETWORK EQUIPMENT PROTECTION. 1/8" = 1'-0" 2 GROUND FLOOR CONSTRUCTION PLAN. 1/813, = 1'—O" SHEET NO: 2 OF 7 SCALE: 1/8'=1'-0' SCALE: 1/8'=1'-0' EX. L 2-1/2"x2-1/2"x3/16" HORIZONTAL BRACE (LOW), TYP. O 0-1 I EX. L 1-1/2"x 1-1/2"x 1/8" J DIAGONAL BRACE (LOW), TYP. CHIMNEY EX. W 10 LOW LTJTT L�J C4 Jacobsen & Horan EX. W1 o Low Engineering, P.C. D4 O o 6 990 South 2nd Street D1 A-501 Ronkonkoma, NY 11779 NOT INrteJ r O: (631) 580-6100 L_ CONTRACT F. (631) 580-6101 , EXISTING ROOF CHIMNEY Z www.jhepc.com PAVERS„ TYP. I . 2 I EX. W 10 LOW II. X w D4 D6 I� STATE EDUCATION LAW FOR ANY D8 D IT IS VIOLATION OF NEW YORK R7 y/ D8 I I Q J�� �� THEPERSD RECTIONSOF A�LICENSEDNG R h �o �� PROFESSIONAL ENGINEER, TO F. ALTER AN ITEM ON THIS DRAWING 2 * j'y i * IN ANY WAY. IF AN ITEM IS DN D3 TYP. I� I � � r, ALTERED. THE ALTERING ENGINEER D5 J I SHALL AFFIX TO THE ITEM D4 J ATF 027Yp Q` HIS/HER SEAL AND THE NOTATION ,�� `ALTERED BY" FOLLOWED BY F NE� HIS/HER SIGNATURE AND THE DATE OF SUCH ALTERATION AND A TYP. ALL DUNNAGE SPECIFIC DESCRIPTION OF THE _J LJ Q STEEL, POSTS, ETC. C2 C 1 ALTERATION. EX. W 10 LOW 8'-10" 3 -5 D1 2 '� C4 CONSULTANT: of C3 12-1 TECHNOLOGY DRIVE, ;` SETAUKET, NY 11733 X I i C5 C5 '[ x' P. 631.689.8450 L _ / ,:„ F. 631.689.8459 2 _ _..- ` ._ _.._.r .__. www.wfcaia.com D7 — D7 D5 EX. W10 (LOW) D1 — N . T E C T S _ _ GO 2 = I `n N NO. DATE SUBMISSION X v r-� w o � 1 10/10/17 ISSUED FOR BID x 2 11/02/17 ISSUED FOR FILING PAVERS THROUGHOUT or o _^ X NOT SHOWN FOR D4 _ w� w w cr_ CLARITY � 1 z I -50 EX. W10 (LOW) M 2'-3„ (Cl r � � 6'_8,r 6'-6,1 a I I I L L_J OUTLINE OF HVAC UNIT ABOVE, TYP. KEY PLAN: x, I f I R E J gg NA f REMOVAL SCHEDULE CONSTRUCTION SCHEDULE ;s t D1 PROVIDE ROOF PROTECTION IN AND AROUND AREAS OF WORK AND STAGING, REFER TO 9/A-501 FOR MORE INFO. C1 FURNISH AND INSTALL (2) NEW STEEL SUPPORT CHANNELS AT GLYCOL PUMPS AS INDICATED ON DUNNAGE PLAN, REFER TO DETAILS 1YA-502 FOR MORE INFO COORDINATE FINAL DIMENSIONS WITH APPROVED MECHANICAL SUBMITTALS. _. D2 REMOVE EXISTING HVAC EQUIPMENT AND ASSOCIATED PIPING AND CONDUIT. REFER TO ENGINEERING DRAWINGS FOR MORE INFO. PAINT ALL NEW AND EXISTING STEEL BEAMS, CROSS BRACING, EXISTING POSTS AND ALL MISC. HARDWARE WITH (1) COAT BENJAMIN MOORE SUPER SPEC HP ACRYLIC METAL PRIMER; C2 (2) COATS ULTRA SPEC HP DTM SEMI-GLOSS ENAMEL. COLOR TO BE GRAY. D3 GRIND AND REMOVE ALL MISCELLANEOUS WELDED ANGLES ABANDONED IN PLACE FROM EXISTING DUNNAGE PLATFORM. ASSUME 80 FOR PURPOSE OF BID. F C3 COORDINATE WITH MECHANICAL CONTRACTOR TO FURNISH AND INSTALL NEW PIPE SUPPORTS, REUSE EXISTING PIPE SUPPORTS WHERE POSSIBLE. REFER TO DETAIL 8/A-501 AND ARFA OF WORK SCRAPE, WIRE BRUSH, SAND AND CLEAN ALL STEEL HANDRAILS, STEEL BEAMS, POSTS, MOUNTING HARDWARE, STAIR CASES, ETC ON EXISTING STEEL DUNNAGE PLATFORM ENGINEERING DRAWINGS FOR MORE INFO. D4 TO PREPARE FOR NEW PAINT. C4 MPROVIDE JEW PIPE PENETRATION PITCH POCKET WITH HOOD, REFER TO DETAIL 6/A-501.00 FOR MORE INFO. D5 REMOVE EXISTING PITCH POCKET, CONDUIT AND GLYCOL PIPING. REFER TO ENGINEERS DRAWINGS FOR MORE INFO. PROVIDE TEMPORARY WEATHERPROOF SECURE ENCLOSURE THROUGHOUT CONSTRUCTION. C5 RELOCATE (2) W6 BEAMS AS INDICATED FOR SUPPORT OF NEW DRY COOLER EQUIPMENT. - PAINT EXISTING STEEL BEAM, GfRATED STEP AND NON-GALVANIZED LANDING AS SPECIFIED BY NOTE C2 ON 2/A-102. FD D7 CAREFULLY REMOVE EXISTING WIELDED W6 BEAM AND CLEAN FOR REUSE, REFER TO CONSTRUCTION PLAN THIS SHEET FOR MORE INFO. D8 REMOVE AND DISCARD (2) EXISTING WELDED W6 BEAMS, GRIND EXISTING PLATFORM SMOOTH, AND PREPARE FOR NEW FINISH. F A/C REPLACEMENT STEEL NOTES NOTE: FOR CARRIER SWRM ALL FINAL MEASUREMENTS MUST BE COORDINATED 1. ALL STEEL FABRICATION AND ERECTION SHALL CONFORM TO AISC SPECIFICATIONS FOR STRUCTURAL WITH MECHANICAL DRAWINGS AND THE FINAL STEEL, LATEST EDITION. PURCHASED EQUIPMENT SIZES. 2. ALL STRUCTUIRAL STEEL W SHAPES SHALL BE ASTM A992 GRADE 50, ALL OTHER SHAPES ASTM A36. 31755 MAIN RD. 3. ALL BOLTS SHALL BE A325 AND SHALL BE INSTALLED TO A SNUG CONDITION AS DEFINED IN AISC CUTCHOGUE, NY SPECIFICATIONS. GROUND FLOOR 4. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN FIELD, COORDINATE STEEL SPACINGS WITH TITLE: MECHANICAL (CONTRACTOR AND SUBMIT SHOP DRAWINGS FOR APPROVAL BY THE ARCHITECT PRIOR TO FABRICATING STEEL. 5. ALL MECHANICAL EQUIPMENT: PIPING AND ELECTRICAL CONDUIT SHALL BE SECURED TO THE STEEL ROOF REMOVAL AND CONSTRUCTION PLAN BEAM DUNNAGE. MECHANICAL EQUIPMENT TO BE FASTENED TO STEEL AT ALL LEGS. 6. ANY ROOFING WORK MUST BE DONE BY AN AUTHORIZED ROOF INSTALLER. ALL WORK WILL BE DATE: 8/16/17 COMPATIBLE WITH THE EXISTING ROOFING SYSTEM AND SHALL IN NO WAY ALTER OR VOID THE PRESENT WARRANTY. THE ROOFER SHALL SO ADVISE THE MANUFACTURER OF ALL PROPOSED WORK PROJECT NO: 17-2165 AND MAINTAIN THE INTEGRITY OF THIS WARRANTY. DRAWN BY: JPK 7. ALL NEW STEEL SHALL BE SHOP PRIMED AND FIELD PAINTED AS SPECIFIED. CHECKED BY: EWS 8. PROVIDE ROOF PROTECTION FOR ALL EQPT., STORED MAT'LS, ETC. REFER TO DETAIL 4/A-501.00 FOR SCALE: AS NOTED " MORE INFO. DRAWING NO: 0' 4' 8' 16' 0' 2' 4' 8' 1 ROOF REMOVAL PLAN 1/8 = 1 -0 2 PART. ROOF CONSTRUCTION PLAN, 1/4 = l'-O" SCALE: 1/8'=1'-0' SCALE: 114'=1'-0' SHEET NO: 3 OF 7 1" MIN. DEPTH 3M FIRE BARRIER CP 25WB+ INSTALLED FLUSH WITH 12 GAUGE GALV. STEEL COVER TOP OF SURFACE OF PLATE CUT TO FIT / SECURED FLOOR OR SLEEVE. TO FIN. CABLE HOLE FRAME STEEL PIPE 30"0 OR PROVIDE NOM 1-5/8" x 4" SMALLER / RIGID STEEL CONDUIT MIN. 5" UL CLASSIFIED 2HR WALL OPENINIG TO BE 7/8" DIAMETER HIGH C4X5.4 STRUCTURAL 6"OOR SMALLER CONC. OR BLOCK WALL. LARGER THAN INSULATED PIPE. STEEL CHANNELS „ COPPER PIPE 6"0 OR 777, .. ,..:. 3 1/2" MINERAL WOOL PACKING. PUTTY (MPS-2+) FILL MATERIAL 15" DIA. OR SMALLER SMALLER APPLIED ON BOTH SIDES OF WALL TO SCHEDULE 10, OR A MIN. DEPTIH OF 5/8" FOR 1 HOUR HEAVIER, STEEL PIPE. CONCRETE SLAB (4-1/2" \ WALL AND 1-1 4" FOR 2 HOUR WALL PIPE MAY EXTEND 2" MIN. THICK ` '3M' MOLDABLE PUTTY MIN. 1" THICK / ) FLUSH WITH WALL SURFACES. MIN. 1/2" ------------------- FROM SURFACE (OPTIONAL OR THICK CROWN AROUND PENETRATING 4 DIAMETER OR SMALLER INSULATED FOR EXISTING CONDUIT) CONCRETE BLOCK WALL ITEM. REFER TO MANUFACTURES STEEL OR COPPER PIPE. IMP/ MY RECOMMENDED INSTALLATION --------------- INSTRUCTIONS. APPLY A MINIMUM 1/4" BEAD OF ° Jacobsen & Horan PIPE OR CONDUIT CPWB CAULK OR MPS-2+ PUTTY a WHERE THE INSULATION TOUCHES THE PLAN VIEW ECCENTRIC a UL CLASSIFIED 2HR STL OR WD. WALL (ECCENJTRIC INSTALLATION). ° a. Engineering, P.C. FIRERATED GYP. WALLBOARD ASSEMBLY. 3M WL-5039 PIPE INSULATION NOM 1/2" TO 2" ° 4 990 South 2nd Street Ronkonkoma, NY 11779 THICK HOLLOW CYLINDRICAL HEAVY ° DENSITY (MIN. 3.5 PCF) FIBER GLASS O: (631) 580-6100 UNITS. 1/2" TO 1-1/2" FOR 2 HOUR F. (631) 580-6101 2HR FIRERATED WALL PENETRATION DETAIL UL SYSTEM No.: C-AJ-1027 (CONCRETE WALL) SLEEVE GROUT IN RATING SOLID www.jhepc.com UL SYSTEM No.: W-L-1080 (GYPSUM BD. PARTITION) PARTITION OUR RATED GYPSUM BOARD POLYETHELYNE BACKER ROD OR MIN. 1" THICK MINERAL WOOL BATT AR IT IWARNING:IOLATION OF NEW YORK pBERT y STATE EDUCATION LAW FOR ANY 0 APPLY MATERIAL TO BOTH INSULATION FIRMLY R PERSON, UNLESS ACTING UNDER SIDES AT CONCRETE CROSS THE DIRECTION OF A LICENSED SECTIONAL VIEW PACKED INTO OPENING. Q y o n� PROFESSIONAL ENGINEER, TO PLAN VIEW CONCENTRIC BLOCK WALL �F ALTER AN ON THIS DRAWING 3M SYSTEM C—AJ- 1044 INANY WAYAN REM ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM 2 FIRESTOPPING AT INS. PIPE THRU GYP. WALL, 3 FIRESTOPPING AT PIPE THRU SLAB OR MASONRYQ� HISTHER SEAL AND THE NOTATION 1 CONDUIT FIRE PROOFING ALTERED BY" FOLLOWED BY THE SCALE 1/4' = T-0' SCALE NTS SCALE NT$ OF NES SPECHIS/FIFIC DESCRIPTION ER SIGNATURE �OF THE DATE OF SUCH ALTERATION AND A ALTERATION. CONSULTANT: 12-1 TECHNOLOGY DRIVE, MBR FLASHING CEMENT; 6"MIN 26 GA. ST. STL. PREFORMED ;; ; SETAUKET,NY 11733 PRIME ALL SURFACES HOOD ' P. 631.689.8450 INCLUDING PIPES — THIS SIDE TO BE OPEN FOR . " 1 OR 2 HOUR RATED GYPSUM BOARD PARTITION 30' F. 631.689.8459 PIPE ENTRY " fi www.wfcaia.com FRICTION FIT MINERAL WOOL OR FIBERGLASS BATT INSULATION ' 2" 5/16" x 2" ST. STL. SCREWS POLYETHYLENE BACKER ROD 3 (2 ea. SIDE) SPACERS BEHIND '' - �3" ;x. ' Y I T E C T S Ln 01 EA. SCREW ON 3 CLOSED > SIDES. NO. DATE SUBMISSION CONTINUOUS 2" GALVANIZED STRAPPING 3PROVIDE BIRD SCREEN f 1 10/10/17 ISSUED FOR BID AT PLYWOOD SEAMS o o f PROTECTION. " FIRE RETARDANT PLYWOOD2 11/02/17 ISSUED FOR FILING MIN. 16 GA. GALV. STEEL ANGLE RETAINING ANGLES ATTACHED N ` I PROVIDE INSULATION/ SLEEVE 1:: TO DUCT ON BOTH SIDES OF WALL. 1" OVERLAP WITH WALL ' —2" WOOD PLANKING (STAGING AND 2" OVERLAP WITH DUCT. WEEPS AROUND PIPING BY "NOMACO" AREAS AREAS ONLY) 1/2" NO.10 (min) SHEET METAL SCREWS AT 6" O.C. EXISTING PITCH 2" RIGID INSULATION BOARD o „ 1/2 NO.10 (min) SHEET METAL 'SCREWS AT 6 O.C. ao o FILL OL D W POCKET NON-SHRINK EXISTING ROOF MEMBRANE GROUT EXISTING ROOFING SYSTEM DUCT DUCT VERTICAL GUILLOTINE TYPE FIRE DAMPER. (REFER TO EXISTING VAPOR BARRIER EXISTING MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION) ROOF CONCRETE SLAB o 0 ASSEMBLY - 1/8” STEEL PLATE TO BE EXPANSION VARIES VOID BETWEEN WALL BOARD AND DUCT, 0" MINIMUM - 2" BOLTED TO BOTTOM OF SLAB, CUT HOLES MAXIMUM. FOR MECH. LINES 1/2" LARGER. USE EXISTING ROOF KEY PLAN: NOTE: PROTECTION BELOW PER VERIZON FIELD MEMBRANE 1. CONTRACTOR RESPONSIBLE FOR SECURING / MIN. 5/8" THICKNESS CP-25WB+ ENGINEERS REQUEST. PLATE NOT REQUIRED VAPOR BARRIER BALLASTING ALL ROOF PROTECTION. FRAME OUT ALL AROUND OPENING. IF HOLES ARE CORE DRILLED, HOWEVER PIPE SLEEVES ARE REQUIRED AND VOID AROUND EXISTING CONC. II _ Irk II 2. CONTRACTOR RESPONSIBLE FOR VERIFYING ROOF LIVE SLEEVES TO BE PACKED TIGHT WITH MORTAR PLANK L.OAD FOR EQUIPMENT STAGING & DISTRIBUTION PRIOR AND SEALED WITH 3M MOLDABLE PUTTY. TO ANY DELIVERIES. 3M W-L-7008 4 ROOF PROTECTION DETAIL, 5 THRU WALL DUCT FIRE STOPPING DETAIL. 6 ROOF PENETRATION DETAIL. ' SCALE NTS SCALE V4' = T-0' SCALE V4' = T-0' ; GENERAL PROTECTION NOTES:_ APXA OF WORK 1. THE PROTECTION DIAGRAMS ARE TO BE USED FOR ALL WORK IN SPACES LISTED AND AS CALLED OUT ON THE CONTRACT DOCUMENTS.THE CONTRACTOR SHALL FOLLOW THE INTENT DESCRIBED, HOWEVER DUE TO VARIATIONS IN EXISTING SPACES, MODIFICATIONS ARE PERMISSIBLE TO THE ACTUAL LAYOUT AND CONFIGURATION OF THE PROTECTION. ALL PROTECTION MUST BE APPROVED BY THE USER AND ARCHITECT PRIOR TO WORK S'TARTING.PLATFORMS SHALL BE INDEPENDENTLY SUPPORTED. DO NOT APPLY ANY LOAD TO VERIZON rl EQUIPMENT OR CABLE TRAYS. 2. CONTRACTOR IS REQUIRED TO PROVIDE AND MAINTAIN ADEQUATE VENTILATION TO ALL TELCO EQUIPMENT AT ALL TIMES. 3. ALL PROPOSED PROTECTION SHALL BE REVIEWED AND APPROVED BY VERIZON CO ENGINEER PRIOR TO ANY INSTALLATION. 4. NO EQUIPMENT PROTECTION SMALL BE SUPPORTED BY TELCO WATER PROOF TARP WITH EDGE MECHANICAL SUPPY / RETURN EQUIPMENT OR CABLE RACKING. GROMMETS. HANG FROM HIGH IRON DUCTWORK A/C REPLACEMENT OR SLAB. TAPE ALL JOINTS. FOR CARRIER SWRM TARP SHALL BE AS LARGE AS FIRE RETARDANT POSSIBLE. AVOID SMALL SECTIONS CABLE TRAYS / RACKSPLYWOOD TO REDUCE JOINTS. 1/4" TEMPERED (BOTH SIDES) PLATFORM. TAPE MASONITE. LEAN AGAINST ALL JOINTS AIR DRAIN AND HOSE. HOSE TO RUN EQUIPMENT. PROVIDE OPENINGS WORK AR TIGHT. ROOF / SLAB ABV. TO FLOOR DRAINS OR COLLECTION AROUND EQUIPMENT INTAKE D RUBBER 31755 MAIN RD. DP/A - t8'-0" HIGH STUDS WITH BARREL FOR WATER PROTECTION. GRILLES. BLANKETS OVER CUTCHOGUE NY 1/4" TEMPERED MASONITE ON NO HOSE REQUIRED FOR DUST / PLACE TAPED SHEETS OF WORK AREA EXPOSED BUS ' SWITCH SIDE. DRAPED REBCO f DEBRIS PROTECTION ONLY. D TEMPERED MASONITE ON FLOOR D BAR. GROUND FLOOR PLASTIC FLOOR OF MASONITE TO OF COMPLETE RIGGING ROUTE. TITLE: ,J CEILING SLAB. >< EXISTING TELEPHONE SWITCHING FIRE RETARDANT PLYWOOD FIRE RETARDANT `J `J EQUIPMENT `J `J MASONITE CAN NOT BE LEFT IN PLATFORM. WOOD STUDS FIRESTOPPING AND POSITION OVER EQUIPMENT. WITH DRAPED DP/B - FIRE RETARDANT WOOD REMOVE AFTER EACH DAY'S REBCO PLASTIC. MISC. DETAILS STUDS WITH DRAPED REBCO THIS PROTECTION MUST BE FIRE RETARDANT WOOD STUDS PLASTIC. INSPECTED BY THE CONTRACTOR WORK. WITH DRAPED REBCO PLASTIC. SEE DETAIL THIS EACH DAY TO VERIFY ALL SHEET FOR JOINTS TO BE SEALED TIGHT. 01 EXISTING TELEPHONE SWITCHING EXISTING POWER J BATTERY DATE: 8/16/17 DP/C - REBCO PLASTIC DRAPED EXISTING TELEPHONE EQUIPMENT ROOM PROTECTION FROM CEILING TO FLOOR SLAB. SWITCHING EQUIPMENT EQUIPMENT FRAMING PROJECT NO: 17-2165 REQUIREMENTS. DRAWN BY: JPK DUST PROT.: A B AND C TEMP. PROTECTION OVER TEMP. PROTECTION AROUND TEMP. PROTECTION OVER PROT. OVER PWR EQUIP. CHECKED BY: EWS TP1TP2 TP3 TP4 SCALE: AS NOTED SWITCHFOR ROOF WORK OVER SWITCH ROOMS SWITCH SWT CHIROOMSEQUIPMENT THROUGH SWITCH FOR WORK INSIDE SWITCHROOMS FOR WORK IN POWER ROOMS DRAWING NO: � 0 "" 7 GENERAL PROTECTION NOTES AND DETAILS Amb SCALE NTS SHEET NO: 4 OF NEW PIPING & ELECTRICAL CONDUIT PIPE CLAMP ASSEMBLY AS REQUIRED (TYP.) REFRIGERANT PIPES; PIPE CLAMP © ELECTRICAL CONDUIT INCLUDE RUBBER OR EQ.,INSERTS INSIDE CLAMP. PIPING SUPPORT BY PORTABLE PIPE STEEL CHANNEL (HG) HANGERS, INC. # PP10 WITH STRUT O O O NEW PUMP PACK PIPING SUPPORTS SET 6'-0" O.C. (MAX) OR WITHIN 18" OF 90' 1'-4" DIRECTION CHANGE (U.O.N.) C° L` ROOFING CEMENT > ASPHALTIC WALKPAD Jacobsen & Horan ROOFING CEMENT lllllj�09O o Engineering, P.C. 990 South 2nd Street Ronkonkoma, NY 11779 EXISTING ROOFING SYSTEM 0: (631) 580-6100 EXISTING VAPOR BARRIER F. (631) 580-6101 CONCRETE ROOF www.jhepc.com MECHANICAL CONTRACTOR EXISTING GRATING 2'-8" WARNING: TO REMAIN CONFIRM FINAL DIMENSIONS WITH TO FURNISH PIPE RISA VIOLATION OF NEW YORK APPROVED MECHANICAL SUBMITTALS SUPPORTS. INSTALLATION EDA STATE EDUCATION LAW FOR ANY R � PERSON, UNLESS ACTING UNDER 3/4"0 A325 BOLT, TYP. OF PIPE SUPPORTS BY GC ()BERT /� THE DIRECTION IECTIPROFESSIONAL ENGINEER,LICENSED TO ALTER AN ITEM ON THIS DRAWING Q o IN ANY WAY. IF AN REM IS NEW PAINTED C6x 13 * � t ALTERED, THE ALTERING ENGINEER 6x6x5/16"x3" LONG ANGLE, TYP. (DS(-'ALE-NON PENETRATING SUPPORT DETAIL _ * SHALL AFFIX TO THE EEM HIS/HER SEAL AND THE NOTATION � .F- "ALTERED BY" FOLLOWED BY 7251 Q` HIS/HER SIGNATURE AND THE NTS 9TF y� DATE OF SUCH ALTERATION AND A OF NE� SPECIFIC DESCRIPTION OF THE EXISTING W10 TO BE CLEANED AND ALTERATION. REPAINTED CONSULTANT: * SEE LENTIL SCHEDULE x + .., FOR ANGLE SIZES AND REMOVE EXISTING MASONRY 12-1 TECHNOLOGY DRIVE, BEARING LENGTH AS REQUIRED TO SET STEEL SETAUKET,NY 11733 LINTEL P. 631.689.8450 `� ` '' � ` F. 631.689.8459 1 PUMP SUPPORT DETAIL, www.wfcaia.com SCALE 1-VT-f-0' 00 Z I T E C T S NO. DATE SUBMISSION 0 1 10/10/17 ISSUED FOR BID 8" MIN. REMOVE EXISTING MASONRY 8" MIN. 2 11/02/17 ISSUED FOR FILING BEARINd FORM NEW MASONRY OPENING loo BEARIN 0 Q Y U O J m x EXISTING MASONRY TO REMAIN (VIF) KEY PLAN: RELOCATED W6 (HIGH) CON C ETRE ES BLOCKS WIDE R , Y BOLTED TO EXISTING W10 (LOW) £J `i (4) 3/4"0 A325 BOLTS PER CONNECTION o0 � 1 it TOOTH IN END PIECES —� 1 EXISTING W10 STEEL BEAM (LOW) OF BRICK AND BLOCK TO PROVIDE SMOOTH € JAMBS, FILL SILL WITH [2] NEW STEEL ANGLE LINTELS . « ••' MORTAR AND MAKE GALVANIZED (EXTERIOR ONLY) "S SMOOTH Z NOTE: 0 ARFA OF WORK �" PROVIDE NEW MORTAR AT FACE rko 2 DUNNAGE FRAMINGDETAIL Z BRICK TO MATCH EXISTING. w TOOL MORTAR JOINTS TO MATCH. SCALE NTS w ww 70 SECTION X-X' SCALE: 1-1/2" = l'-O" EXTERIOR EXISTING EXTERIOR MASONRY WALL 4-6"f VIF EXISTING EXTERIOR LOUVER -------------------- CONTINUOUS 1"x1"x1/8" ALUMINUM ANGLE MECHANICALLY STRUCTURAL STEEL LOOSE LINTEL SCHEDULE FASTENED TO EALUM MASONRY WALL XISTING MAX REINF. IN. uNTELS ONRY A/C REPLACEMENT ow In 2" THICK EMBOSSED ALUMINUM 0 EN G 4~ WALL 6~ WALL 8~ Wim- 12w WALL FOR CARRIER SWRM ww - - - - SKINNED METAL PANEL, >( ; +I � o MAPES-R+ WITH 3'-0" 1 - L 3-1/2x3-1/2x1/4 2 - JL 3x2-1/2x1/4 2 - JL 3-1/2x3-1/2x1/4 3 -JJL 3-1/2x3-1/2x1/4 o 0 _ POLYISOCYANU RATE INSULATION I X D iv 41-09v 1 - L 4x3-1/2x 1/4 2 - JL 3x2-1/2x 1/4 2 - JL 43-1/20/4 3 -JJL 4x3-1/2x 1/4 00 0 AND HARDBOARD SUBSTRATES. 3�7 MAIN RD. I o COLOR: COLONIAL WHITE 5'-0" 1 - L 4x3-1/2x 1/4 2 - JL 3-1/2x2-1/2x 1/4 2 - JL 5x3-1/2x 1/4 3 -JJL 4-1/2x3-1/2x 1/4 a m 6'-0" 1 - L 50-1/20/4 2 - JL 3-1/2x2-1/2x 1/4 2 - JL 5x3-1/2x 1/4 3 -JJL 5x3-1/2x 1/4 CUTCHOGUE, NY I LL- Y 8'-0» ----- 2 - JL 3-1/2x2-1/2x 1/4 2 - J L 6x3-1/20/8 3 -JJL 60-1/20/8 GROUND FLOOR NOTES: TITLE: I INTERIOR PROVIDE CONTINUOUS BEAD OF 1. PROVIDE AND INSTALL LINTEL ANGLES FOR MASONRY OPENING IN ACCORDANCE WITH THE SCHEDULE ABOVE UNLESS OTHERWISE L----------J--------- I SILICONE CAULK NOTED ON PLAN - INSTALL LONG LEG VERTICAL. DETAILS L _ _ _ J 2. PROVIDE 8" MINIMUM BEARING AT EACH END BUT NOT LESS THAN 1" PER FOOT OF SPAN. FILL 2 COURSES OF MASONRY BELOW 1" REVEAL BEARING WITH MORTAR. PANEL ELEVATION SECTION X 3. WHERE MINIMUM BEARING CANNOT BE PROVIDED, ATTACH SECURELY TO ADJACENT STRUCTURAL MEMBER OR PROVIDE SEPARATE SCALE: 3/8'=1'-0' SCALE: 3'=1'-0' SUPPORTS. 4. WHERE LINTELS OCCUR IN EXTERIOR WALLS, MINIMUM THICKNESS SHALL BE 5/16 " AND ANGLES SHALL BE HOT DIPPED DATE: 8/16/17 GALVANIZED. ALL INTERIOR LINTELS TO BE PAINTED. PROJECT NO: 17-2165 5. WHERE WALL THICKNESS EXCEEDS 12" PROVIDE 1 ADDITIONAL ANGLE FOR EACH ADDITIONAL 4" OF WALL. DRAWN BY: JPK 6. ALL LINTELS MORE THAN 4'-0" LONG TO BE FIREPROOFED. • CHECKED BY: EWS SCALE: AS NOTED DRAWING NO: ELEVATION Y INSTALL S/S SHEET METAL AM 3 IN ULATED PANEL ASSEMBLY DETAIL SCALE: 1-1/2'4-0' SCREWS AND OVERSIZED S/S 5 LINTEL S WASHERS SCHEDULE AND DETAILS SCALE AS NOT® SCALE NTS SHEET NO: 5 OF 7 020700 - SELECTIVE DEMOLITION 1. PROVIDE AT LEAST 72 HOURS' NOTICE TO OWNER IF SHUTDOWN OF SERVICE IS REQUIRED DURING SECTION 078400- THROUGH-PENETRATION FIRESTOP SYSTEMS E. DURING INSTALLATION, PROVIDE MASKING AND DROP CLOTHS TO PREVENT FIRESTOPPING MATERIALS FROM CHANGEOVER. PART 1.00 - GENERAL CONTAMINATING ANY ADJACENT SURFACES. PART 1.00 - GENERAL 2. RETAIN ONE OF TWO "UTILITY REQUIREMENTS" PARAGRAPHS AND ASSOCIATED SUBPARAGRAPHS BELOW, IF PART 2.00 - PRODUCTS APPLICABLE. 1.1 RELATED DOCUMENTS 2.1 FIRESTOPPING, GENERAL 1.1 RELATED DOCUMENTS A. UTILITY REQUIREMENTS: LOCATE, IDENTIFY, DISCONNECT, AND SEAL OR CAP OFF INDICATED UTILITIES SERVING A. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND A. PROVIDE FIRESTOPPING COMPOSED OF COMPONENTS THAT ARE COMPATIBLE WITH EACH OTHER, THE A. THE SUBCONTRACT BETWEEN CONSTRUCTION MANAGER / GENERAL CONTRACTOR AND SUBCONTRACTOR, AND ALL AREAS TO BE SELECTIVELY DEMOLISHED. DIVISION-1 SPECIFICATION SECTION, APPLY TO WORK SPECIFIED IN THIS SECTION. SUBSTRATES FORMING OPENINGS, AND THE ITEMS, IF ANY, PENETRATING THE FIRESTOPPING UNDER CONDITIONS j SUBCONTRACT GENERAL CONDITIONS, SPECIAL CONDITIONS, AND ALL EXHIBITS APPENDED THERETO INCLUDING 1. ARRANGE TO SHUT OFF INDICATED UTILITIES WITH UTILITY COMPANIES. 1.2 DEFINITIONS OF SERVICE AND APPLICATION, AS DEMONSTRATED BY THE FIRESTOPPING MANUFACTURER BASED ON TESTING 1'1° 11 ALL DRAWINGS AND SPECIFICATIONS. A. FIRESTOPPING: MATERIAL OR COMBINATION OF MATERIALS USED TO RETAIN INTEGRITY OF FIRE-RATED AND FIELD EXPERIENCE. 2. IF UTILITY SERVICES ARE REQUIRED TO BE REMOVED, RELOCATED, OR ABANDONED, PROVIDE TEMPORARY CONSTRUCTION BY MAINTAINING AN EFFECTIVE BARRIER AGAINST THE SPREAD OF FLAME, SMOKE, AND HOT B. PROVIDE COMPONENTS FOR EACH FIRESTOPPING SYSTEM THAT ARE NEEDED TO INSTALL FILL MATERIAL. USE 1.2 SUMMARY UTILITIES BEFORE PROCEEDING WITH SELECTIVE DEMOLITION THAT BYPASS AREA OF SELECTIVE DEMOLITION GASES THROUGH PENETRATIONS IN FIRE RATED WALL AND FLOOR ASSEMBLIES. ONLY COMPONENTS SPECIFIED BY THE FIRESTOPPING MANUFACTURER AND APPROVED BY THE QUALIFIED AND THAT MAINTAIN CONTINUITY OF SERVICE TO OTHER PARTS OF BUILDING. TESTING AGENCY FOR THE DESIGNATED FIRE-RESISTANCE-RATED SYSTEMS. A. THIS SECTION INCLUDES DEMOLITION AND/OR TEMPORARY REMOVAL OF THE FOLLOWING: 3. CUT OFF PIPE OR CONDUIT IN WALLS OR PARTITIONS TO BE REMOVED. CAP, VALVE, OR PLUG AND SEAL 1.3 SUMMARY C. FIRESTOPPING MATERIALS ARE EITHER "CAST-IN-PLACE" (INTEGRAL WITH CONCRETE PLACEMENT) OR "POST "71 Isr 1. INTERIOR PARTITIONS AS INDICATED ON DRAWINGS AS "REMOVE" OR AS DASHED LINES. REMAINING PORTION OF PIPE OR CONDUIT AFTER BYPASSING. INSTALLED." PROVIDE CAST-IN-PLACE FIRESTOP DEVICES PRIOR TO CONCRETE PLACEMENT. A. THESE PROCEDURES ARE SPECIFIED TO PROVIDE METHODS TO RESTORE THE INTEGRITY OF FIRE-RATED 2. REMOVAL OF DOORS, FRAMES AND ALL ASSOCIATED HARDWARE AS INDICATED DRAWINGS. B. UTILITY REQUIREMENTS: REFER TO DRAWINGS FOR SHUTTING OFF, DISCONNECTING, REMOVING, AND SEALING OR BARRIERS AS REQUIRED BY CODES, LAWS, AND REGULATIONS AND NECESSARY FOR THE PROTECTION OF 2.2 ACCEPTABLE MANUFACTURERS .H CAPPING UTILITIES. DO NOT START SELECTIVE DEMOLITION WORK UNTIL UTILITY DISCONNECTING AND SEALING VERIZON EMPLOYEES AND PROPERTY AND PROVIDING CONTINUITY OF NETWORK SERVICE. WHERE ANY FEDERAL, .2 SUBJECT TO COMPLIANCE WITH THROUGH PENETRATION FIRESTOP SYSTEMS XHEZ LISTED IN VOLUME II OF THE 3. REMOVAL OF SELECTIVE ROOFING AREAS TO ACCOMMODATE NEW PIPE AND CONDUIT INSTALLATIONS AS HAVE BEEN COMPLETED AND VERIFIED IN WRITING. PROVINCIAL, STATE, OR LOCAL CODES, LAWS, OR REGULATIONS OF THE PUBLIC AUTHORITIES HAVING UL FIRE RESISTANCE DIRECTORY, PROVIDE PRODUCTS OF THE FOLLOWING MANUFACTURERS AS IDENTIFIED INDICATED ON PLANS. JURISDICTION AT THE LOCATION IMPOSE MORE STRINGENT REQUIREMENTS THAN THOSE CITED IN THIS STANDARD, 4. REMOVAL OF SELECTIVE FLOOR SLABS, SURFACES, AND MISCELLANEOUS FINISHES AS INDICATED ON 3.3 PREPARATION THOSE CODES, LAWS, OR REGULATIONS SHALL BE FOLLOWED. BELOW: Jacobsen Horan DRAWINGS. A. SITE ACCESS AND TEMPORARY CONTROLS: CONDUCT SELECTIVE DEMOLITION AND DEBRIS-REMOVAL OPERATIONS B. THIS SPECIFICATION HAS INCORPORATED THE PASSIVE FIRE PROTECTION PRODUCTS AND FIRE RATED ASSEMBLIES 1. HILTI, INC., TULSA, OKLAHOMA B. SEE DRAWINGS FOR DEMOLISHING, CUTTING, PATCHING, OR RELOCATING MECHANICAL ITEMS. TO ENSURE MINIMUM INTERFERENCE WITH ROADS, STREETS, WALKS, WALKWAYS, AND OTHER ADJACENT OCCUPIED OF THE 3M COMPANY. THIS WAS DONE IN ORDER TO PRESENT UL APPROVED AND CODE COMPLIANT DETAILS 800-879-8000/WWW.US.HILTI.COM AND USED FACILITIES. OF FIRE RATED ASSEMBLIES. WITHIN VERIZON OWNED BUILDINGS, HILTI CONSTRUCTION CHEMICALS, INC. IS THE C. SEE DRAWINGS FOR DEMOLISHING, CUTTING, PATCHING, OR RELOCATING ELECTRICAL ITEMS. 2. PROVIDE PRODUCTS FROM THE ABOVE ACCEPTABLE MANUFACTURER; NO SUBSTITUTIONS WILL BE ACCEPTED. ACCEPTABLE MANUFACTURER OF FIRE-RATED PRODUCTS AND ASSEMBLIES FOR USE. DETAILS FOR FIRE-RATED Engineering, f.C. 1. DO NOT CLOSE OR OBSTRUCT STREETS, WALKS, WALKWAYS, OR OTHER ADJACENT OCCUPIED OR USED ASSEMBLIES USING HILTI CONSTRUCTION CHEMICALS, INC. MAY VARY FROM THE DETAILS PRESENTED IN THIS 2.3 MATERIALS FACILITIES WITHOUT PERMISSION FROM OWNER AND AUTHORITIES HAVING JURISDICTION. PROVIDE ALTERNATE STANDARD. VERIFY THE FIRE RATING OF THE ASSEMBLY CHOSEN WITH ITS MANUFACTURER. COMPONENTS OF A. USE ONLY FIRESTOP PRODUCTS THAT HAVE BEEN UL 1479 OR ASTM E 814 TESTED FOR SPECIFIC FIRE-RATED 990 South 2nd Street 1.3 DEFINITIONS ROUTES AROUND CLOSED OR OBSTRUCTED TRAFFIC WAYS IF REQUIRED BY GOVERNING REGULATIONS. ONE MANUFAC'TURER'S ASSEMBLY SHOULD NOT BE INTERCHANGED WITH THE COMPONENTS OF ANOTHER CONSTRUCTION CONDITIONS CONFORMING TO CONSTRUCTION ASSEMBLY TYPE, PENETRATING ITEM TYPE, ANNULAR A. REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSE OF THEM OFF-SITE, UNLESS 2. ERECT TEMPORARY PROTECTION, SUCH AS WALKS, FENCES, RAILINGS, CANOPIES, AND COVERED PASSAGEWAYS, MANUFACTURER''S ASSEMBLY. SPACE REQUIREMENTS, AND FIRE-RATING INVOLVED FOR EACH SEPARATE INSTANCE. Ronkonkoma, NY 11779 INDICATED TO BE REMOVED AND SALVAGED OR REMOVED AND REINSTALLED. WHERE REQUIRED BY AUTHORITIES HAVING JURISDICTION. C. THE FIRESTOP MATERIAL USED WITHIN A VERIZON OWNED FACILITY SHALL BE, ONE OF THE THREE APPROVEDO: (631) 580-6100 B. REMOVE AND SALVAGE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND DELIVER THEM TO OWNER AS B. CAST-IN PLACE FIRESTOP DEVICES FOR USE WITH COMBUSTIBLE AND NON-COMBUSTIBLE PIPES (CLOSED 3. PROTECT EXISTING SITE IMPROVEMENTS, APPURTENANCES, AND LANDSCAPING TO REMAIN. MANUFACTURERS, SELECTED BASED UPON THE PREDOMINANTLY USED MATERIAL IN THE BUILDING. WHERE THE AND OPEN PIPING SYSTEMS) AND CABLE BUNDLES PENETRATING CONCRETE FLOORS, THE FOLLOWING PRODUCTS F. (631) 580-6101 INDICATED. PROJECT IS INI A LEASED FACILITY OR QUARTER, WHICH PREDOMINANTLY EMPLOYS A NATIONALLY RECOGNIZED REVISE PARAGRAPH AND SUBPARAGRAPHS ABOVE AND FIRST PARAGRAPH BELOW TO SUIT PROJECT. DELETE BOTH IF CCom FIRE PROOFING SYSTEM, MATCH THE BUILDING STANDARD. ARE ACCEPTABLE: www.jhepc.com REMOVE AND REINSTALL: DETACH ITEMS FROM EXISTING CONSTRUCTION WHERE INDICATED FOR REUSE, PROTECT ADEQUATELY COVERED IN DIVISION 1 SECTION "TEMPORARY FACILITIES AND CONTROLS." AND STORE IN LOCATIONS AS DIRECTED BY CONSTRUCTION MANAGER. D. THIS SECTION INCLUDES THROUGH-PENETRATION FIRESTOP SYSTEMS FOR THE FOLLOWING TYPES OF 1• HILTI CP 680 CAST-IN PLACE FIRESTOP DEVICE WWW. B. TEMPORARY FACILITIES: PROVIDE TEMPORARY BARRICADES AND OTHER PROTECTION REQUIRED TO PREVENT FIRE-RESISTANCE-RATED ASSEMBLIES: a. ADD AERATOR ADAPTOR WHEN USED IN CONJUNCTION WITH AERATOR ("SOVENT') SYSTEM. D. EXISTING TO REMAIN: EXISTING ITEMS OF CONSTRUCTION THAT ARE NOT TO BE REMOVED AND THAT ARE NOT INJURY TO PEOPLE AND DAMAGE TO ADJACENT BUILDINGS AND FACILITIES TO REMAIN. OTHERWISE INDICATED TO BE REMOVED, REMOVED AND SALVAGED, OR REMOVED AND REINSTALLED. ADJUST LIST BELOW TO SUIT PROJECT. 2. HILTI CP 681 TUB BOX KIT FOR USE WITH TUB INSTALLATIONS. IT IS V MIOLATION OF NEW YORK C. TEMPORARY PARTITIONS: ERECT AND MAINTAIN DUSTPROOF PARTITIONS AND TEMPORARY ENCLOSURES TO LIMIT STATE EDUCATION LAW FOR ANY DUST AND DIRT MIGRATION AND TO SEPARATE AREAS FROM FUMES AND NOISE AS INDICATED ON THE DRAWINGS. 1. FLOORS. 3. HILTI CP 682 CAST-IN PLACE FIRESTOP DEVICE FOR USE WITH NONCOMBUSTIBLE PENETRANTS L, PERSON, UNLESS ACTING UNDER T 7I THE DIRECTION OF A LICENSED 1.4 MATERIALS OWNERSHIP �C a° ;A PROFESSIONAL ENGINEER, TO D. TEMPORARY SHORING: PROVIDE AND MAINTAIN INTERIOR SHORING, BRACING, OR STRUCTURAL SUPPORT TO 2. WALLS AND PARTITIONS. C. SEALANTS, CAULKING MATERIALS, OR FOAMS FOR USE WITH NON-COMBUSTIBLE ITEMS INCLUDING STEEL PIPE �� �0 ALTER AN ITEM ON THIS DRAWING PRESERVE STABILITY AND PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OF CONSTRUCTION TO REMAIN, AND , y o �{ IN ANY WAY. IF AN REM IS A. EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO PREVENT UNEXPECTED OR UNCONTROLLED MOVEMENT OR COLLAPSE OF CONSTRUCTION BEING DEMOLISHED. 3. SMOKE BARRIERS. COPPER PIPE, RIGID STEEL CONDUIT AND ELECTRICAL METALLIC TUBING (EMT), THE FOLLOWING PRODUCTS ARE ALTERED, THE ALTERING ENGINEER TO REMAIN OWNER'S PROPERTY, DEMOLISHED MATERIALS SHALL BECOME CONTRACTOR'S PROPERTY AND SHALL 4. CONSTRUCTION ENCLOSING COMPARTMENTALIZED AREAS ACCEPTABLE: _ * SHALL AFFIX TO THE ITEM BE PROMPTLY REMOVED FROM PROJECT SITIE. E. SIDEWALK CLOSINGS AND BRIDGES: WHERE SIDEWALK BRIDGES OR SIDEWALK CLOSINGS ARE REQUIRED, SECURE 1'? HIS/HER SEAL AND THE NOTATION APPROVALS AND PERMITS FROM ALL APPROPRIATE GOVERNING AGENCIES HAVING JURISDICTION PRIOR TO 1.4 GENERAL DESCRIPTION OF THE WORK OF THIS SECTION 1. HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT (P a 'ALTERED BY' FOLLOWED BY p27 P HIS/HER SIGNATURE AND THE EFFECTING CLOSURE OR ERECTING BRIDGE. ONLY TESTED FIRESTOP SYSTEMS SHALL BE USED IN SPECIFIC LOCATIONS AS FOLLOWS: 2. HILTI CP 604 SELF-LEVELING FIRESTOP SEALANT .." y� DATE OF SUCH ALTERATION AND A 1.5 SUBMITTALS D. PENETRATIONS FOR THE PASSAGE OF DUCT, CABLE, CABLE TRAY, CONDUIT, PIPING, ELECTRICAL BUSWAYS AND 3. HILTI CP 620 FIRE FOAM F OF NES ALTERATION.DESCRIPTION OF THE 3.4 POLLUTION CONTROLS RACEWAYS THROUGH FIRE-RATED VERTICAL BARRIERS (WALLS AND PARTITIONS), HORIZONTAL BARRIERS ALTERATION. A. PROPOSED CONTROL MEASURES: SUBMIT STATEMENT OR DRAWING THAT INDICATES THE MEASURES PROPOSED 4. HILTI CP606 FLEXIBLE FIRESTOP SEALANT FOR USE, PROPOSED LOCATIONS, AND PROPOSED TIME FRAME FOR THEIR OPERATION. IDENTIFY OPTIONS IF REVISE METHODS IN FIRST PARAGRAPH AND SUBPARAGRAPH BELOW TO SUIT PROJECT. WATER MIST MAY NOT BE (FLOOR/CEILING ASSEMBLIES), AND VERTICAL SERVICE SHAFT WALLS AND PARTITIONS. ACCEPTABLE AND IS OF PARTICULAR CONCERN IN HEALTHCARE RENOVATIONS WHERE INFECTION-CONTROL MEASURES, 5. HILTI CP 601S ELASTOMERIC FIRESTOP SEALANT CONSULTANT: PROPOSED MEASURES ARE LATER DETERMINED TO BE INADEQUATE. INCLUDE MEASURES FOR THE FOLLOWING: E. BLANK OPENINGS THROUGH FIRE-RATED VERTICAL BARRIERS (WALLS AND PARTITIONS), HORIZONTAL INCLUDING SUPPRESSING FUNGAL GROWTH, ARE CRITICAL. ' ,: 12-1 TECHNOLOGY DRIVE, 1. DUST CONTROL. BARRIERS (FLOOR/CEILING ASSEMBLIES), AND VERTICAL SERVICE SHAFT WALLS AND PARTITIONS. D SEALANACCEPTTS E: 1OR CAULKING MATERIALS FOR USE WITH SHEET METAL DUCTS, THE FOLLOWING PRODUCTS ARE SETAUKET, NY 117.33 A. DUST CONTROL: USE WATER MIST, TEMPORARY ENCLOSURES, AND OTHER SUITABLE METHODS TO LIMIT SPREAD F. OPENINGS AND PENETRATIONS IN FIRE-RATED PARTITIONS OR WALLS CONTAINING FIRE DOORS. . 11 +.. 2. NOISE CONTROL. OF DUST AND DIRT. COMPLY WITH GOVERNING ENVIRONMENTAL-PROTECTION REGULATIONS. 1. HILTI CP 601S ELASTOMERIC FIRESTOP SEALANT :' � P. 631.689.8450 B. REFER TO CONTRACT DOCUMENT DETAILS FOR MINIMUM LEVELS OF AREA PROTECTION REQUIRED AND 1. WET MOP FLOORS TO ELIMINATE TRACTABLE DIRT AND WIPE DOWN WALLS AND DOORS OF DEMOLITION G. OPENINGS AROUND STRUCTURAL MEMBERS, WHICH PENETRATE FLOORS OR WALLS. y '� r F. 631.689.8459 PROTECTION DETAILS. ALL PROTECTION PLANS SHALL BE REVIEWED BY VERIZON NETWORK MANAGER AT THE ENCLOSURE. VACUUM CARPETED AREAS. 1.5 RELATED WORK OF OTHER SECTIONS 2. HILTI CP 606 FLEXIBLE FIRESTOP SEALANT ,/ " ,;. PRECEDING MOP METHOD OF PROCEDURE) FOR EACH AREA AFFECTED BY WORK. 3. HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT i; www.wfcaia.com . , ( A. COORDINATE WORK OF THIS SECTION WITH WORK OF OTHER SECTIONS AS REQUIRED TO PROPERLY EXECUTE ,i; B. DISPOSAL: REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE ON ADJACENT r . C. SCHEDULE OF SELECTIVE DEMOLITION ACTIVIITIES: INDICATE DETAILED SEQUENCE OF SELECTIVE DEMOLITION AND SURFACES AND AREAS. THE WORK AND AS NECESSARY TO MAINTAIN SATISFACTORY PROGRESS OF THE WORK OF OTHER SECTIONS, . REMOVAL WORK, WITH STARTING AND ENDIING DATES FOR EACH ACTIVITY, INTERRUPTION OF UTILITY SERVICES, INCLUDING: E. INTUMESCENT SEALANTS, CAULKING MATERIALS FOR USE WITH COMBUSTIBLE ITEMS (PENETRANTS CONSUMED BY `'_:_11 I T E C T S USE OF ELEVATOR AND STAIRS, AND LOCATIONS OF TEMPORARY PARTITIONS AND MEANS OF EGRESS. 1. REMOVE DEBRIS FROM ELEVATED PORTIONS OF BUILDING BY CHUTE, HOIST, OR OTHER DEVICE THAT WILL 1• SECTION 03300 - CAST-IN-PLACE CONCRETE HIGH HEAT AND FLAME) INCLUDING INSULATED METAL PIPE, PVC JACKETED, FLEXIBLE CABLE OR CABLE CONVEY DEBRIS TO GRADE LEVEL IN A CONTROLLED DESCENT. BUNDLES AND PLASTIC PIPE, THETOLLOWING PRODUCTS ARE ACCEPTABLE: 1.6 QUALITY ASSURANCE C. CLEANING: CLEAN ADJACENT STRUCTURES AND IMPROVEMENTS OF DUST, DIRT, AND DEBRIS CAUSED BY 2. SECTION 04200 - MASONRY WORK 1. HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT NO. DATE SUBMISSION SELECTIVE DEMOLITION OPERATIONS. RETURN ADJACENT AREAS TO CONDITION EXISTING BEFORE SELECTIVE 3. SECTION 07842 - FIRE-RESISTIVE JOINT SYSTEMS A. DEMOLITION FIRM QUALIFICATIONS: AN EXPDEMOLITION OPERATIONS BEGAN.EXPERIENCED FIRM THAT HAS SPECIALIZED IN DEMOLITION WORK SIMILAR 4. SECTION 07900 - JOINT SEALERS F. FOAMS, INTUMESCENT SEALANTS, OR CAULKING MATERIALS FOR USE WITH FLEXIBLE CABLE OR CABLE BUNDLES, 1 10/10/17 ISSUED FOR BID IN MATERIAL AND EXTENT TO THAT INDICATED FOR THIS PROJECT. 3.5 SELECTIVE DEMOLITION THE FOLLOWING PRODUCTS ARE ACCEPTABLE: 2 11/02/17 ISSUED FOR FILING 5. SECTION 09200 - LATH AND PLASTER 1. HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT B. STANDARDS: COMPLY WITH ANSI A10.6 AND NFPA 241. A. GENERAL: DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW 6. SECTION 09250 - GYPSUM DRYWALL SYSTEMS CONSTRUCTION AND AS INDICATED. USE METHODS REQUIRED TO COMPLETE THE WORK WITHIN LIMITATIONS OF 2. HILTI CP 620 FIRE FOAM 1.7 PROJECT CONDITIONS GOVERNING REGULATIONS. NOTE REFER TO INSTRUCTIONS IN SECTION "G" ITEM NO. 2 ABOVE FOR SPECIFIC 7. SECTION 13080 - SOUND, VIBRATION AND SEISMIC CONTROL 3. HILTI CP 601S ELASTOMERIC FIRESTOP SEALANT INSTRUCTION REGARDING WALL REMOVALS ON EAST BUILDING WALL. 8. SECTION 13900 - FIRE SUPPRESSION AND SUPERVISORY SYSTEMS A. OWNER WILL OCCUPY PORTIONS OF BUILDING IMMEDIATELY ADJACENT TO SELECTIVE DEMOLITION AREA. 1. NEATLY CUT OPENINGS AND HOLES PLUMB, SQUARE, AND TRUE TO DIMENSIONS REQUIRED. USE CUTTING 4. HILTI 606 FLEXIBLE , I SEALANT 9 CONDUCT SELECTIVE DEMOLITION SO OWNER'S OPERATIONS WILL NOT BE DISRUPTED. PROVIDE NOT LESS THAN METHODS LEAST LIKELY TO DAMAGE CONSTRUCTION TO REMAIN OR ADJOINING CONSTRUCTION. . SECTION 15050 - BASIC MECHANICAL MATERIALS AND METHODS G. NON CURING, RE-PENETRABLE, INTUMESCENT PUTTY OR FOAM MATERIALS FOR USE WITH FLEXIBLE CABLE OR 72 HOURS' NOTICE TO OWNER OF ACTIVITIES THAT WILL AFFECT OWNER'S OPERATIONS. 10.SECTION 15250 - MECHANICAL INSULATION CABLE BUNDLES, THE FOLLOWING PRODUCTS ARE ACCEPTABLE: 2. CUT OR DRILL FROM THE EXPOSED OR FINISHED SIDE INTO CONCEALED SURFACES TO AVOID MARRING 1. IF DEMOLITION ACTIVITIES WERE NOT SPECIFICALLY COVERED IN THE GENERAL M.O.P., THEN CONDUCT A EXISTING FINISHED SURFACES. 11.SECTION 15300 - FIRE PROTECTION 1. HILTI CP 618 FIRESTOP PUTTY STICK SPECIFIC AND SEPARATE M.O.P. FOR DEMOLITION 3. DO NOT USE CUTTING TORCHES UNTIL WORK AREA IS CLEARED OF FLAMMABLE MATERIALS. AT CONCEALED 12.SECTION 15400 - PLUMBING 2. HILTI CP 658T FIRESTOP PLUG B. MAINTAIN ACCESS TO EXISTING WALKWAYS, CORRIDORS, AND OTHER ADJACENT OCCUPIED OR USED FACILITIES. SPACES, SUCH AS DUCT AND PIPE INTERIORS, VERIFY CONDITION AND CONTENTS OF HIDDEN SPACE BEFORE ING OPERATIONS. MAINTAIN FIRE WATCH AND PORTABLE FIRE-SUPPRESSION DEVICES 13.SECTION 16050 - BASIC ELECTRICAL MATERIALS AND METHODS H. WALL OPENING PROTECTIVE MATERIALS FOR USE WITH U.L. LISTED METALLIC AND SPECIFIED NONMETALLIC STARTING FLAME-CUTT 1. DO NOT CLOSE OR OBSTRUCT WALKWAYS, CORRIDORS, OR OTHER OCCUPIED OR USED FACILITIES WITHOUT DURING FLAME-CUTTING OPERATIONS. 1.6 REFERENCES OUTLET BOXES, THE FOLLOWING PRODUCTS ARE ACCEPTABLE: WRITTEN PERMISSION FROM AUTHORITIES HAVING JURISDICTION. 1. HILTI CP 617 FIRESTOP PUTTY PAD 4. LOCATE SELECTIVE DEMOLITION EQUIPMENT AND REMOVE DEBRIS AND MATERIALS SO AS NOT TO IMPOSE A. TEST REQUIREMENTS: ASTM E 814, "STANDARD METHOD OF FIRE TESTS OF THROUGH PENETRATION FIRE STOPS" C. OWNER ASSUMES NO RESPONSIBILITY FOR CONDITION OF AREAS TO BE SELECTIVELY DEMOLISHED. EXCESSIVE LOADS ON SUPPORTING WALLS, FLOORS, OR FRAMING. B. TEST REQUIREMENTS: UL 1479, "FIRE TESTS OF THROUGH-PENETRATION FIRESTOPS" 1. CONDITIONS EXISTING AT TIME OF INSPECTION FOR BIDDING PURPOSE WILL BE MAINTAINED BY OWNER AS B. EXISTING FACILITIES: COMPLY WITH BUILDING MANAGER'S REQUIREMENTS FOR USING AND PROTECTING I. FIRESTOP COLLAR OR WRAP DEVICES ATTACHED TO ASSEMBLY AROUND COMBUSTIBLE PLASTIC PIPE (CLOSED FAR AS PRACTICAL. ELEVATORS, STAIRS, WALKWAYS, LOADING DOCKS, BUILDING ENTRIES, AND OTHER BUILDING FACILITIES DURING C. UNDERWRITERS LABORATORIES (UL) OF NORTHBROOK, IL PUBLISHES TESTED SYSTEMS IN THEIR "FIRE AND OPEN PIPING SYSTEMS), THE FOLLOWING PRODUCTS ARE ACCEPTABLE: KEY PLAN: D. HAZARDOUS MATERIALS: IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS WILL BE ENCOUNTERED IN THE SELECTIVE DEMOLITION OPERATIONS. RESISTANCE DIRECTORY" THAT IS UPDATED ANNUALLY. 1. HILTI CP 643N FIRESTOP COLLAR WORK. C. REMOVED AND SALVAGED ITEMS: 1. UL FIRE RESISTANCE DIRECTORY: 2. HILTI CP 644 FIRESTOP COLLAR 1. HAZARDOUS MATERIALS WILL BE REMOVEID BY OWNER BEFORE START OF THE WORK. 1. CLEAN SALVAGED ITEMS. a. FIRESTOP DEVICES (XHJI) - 1 2. IF MATERIALS SUSPECTED OF CONTAINIING HAZARDOUS MATERIALS ARE ENCOUNTERED, DO NOT DISTURB; b. FIRE RESISTANCE RATINGS (BXRH) 3. HILTI CP 645/648 WRAP STRIPS CONTAINERS `� "I 2. PACK OR CRATE ITEMS AFTER CLEANING. IDENTIFY CONTENTS OF . c. THROUGH-PENEITRATION FIRESTOP SYSTEMS (XHEZ) I d�' IMMEDIATELY NOTIFY ARCHITECT AND OWNER. HAZARDOUS MATERIALS WILL BE REMOVED BY OWNER UNDER A ' J. MATERIALS USED FOR LARGE OPENINGS AND COMPLEX PENETRATIONS MADE TO ACCOMMODATE CABLE TRAYS i ' SEPARATE CONTRACT. 3. STORE ITEMS IN A SECURE AREA UNTIL DELIVERY TO OWNER. d. FILL, VOIDS, OR CAVITY MATERIAL (XHHW) AND BUNDLES, MULTIPLE STEEL AND COPPER PIPES, ELECTRICAL BUSWAYS IN RACEWAYS, THE FOLLOWING I E. HAZARDOUS MATERIALS: HAZARDOUS MATERIALS MAY BE PRESENT IN BUILDING, OR PORTIONS THERE OF, TO 4. TRANSPORT ITEMS TO OWNER'S STORAGE AREA ON-SITE DESIGNATED BY OWNER. e. FORMING MATERIALS (XHKU) PRODUCTS ARE ACCEPTABLE: f I =,, BE SELECTIVELY DEMOLISHED. A REPORT ON THE PRESENCE OF HAZARDOUS MATERIALS IS ON FILE FOR . PROTECT ITEMS FROM DAMAGE DURING TRANSPORT AND STORAGE. D. INTERNATIONAL FIRESTOP COUNCIL GUIDELINES FOR EVALUATING FIRESTOP SYSTEMS ENGINEERING JUDGMENTS 1. HILTI CP 637 FIRESTOP MORTAR '} 5 REVIEW AND USE. EXAMINE REPORT TO BECOME AWARE OF LOCATIONS WHERE HAZARDOUS MATERIALS ARE E. ASTM E 84, STANDARD TEST METHOD FOR SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS. 2. HILTI FS 657 FIRE BLOCK p PRESENT. D. REMOVED AND REINSTALLED ITEMS: Ia c % F. INSPECTION RDQUIREMENTS: ASTM E 2174, "STANDARD PRACTICE FOR ON-SITE INSPECTION OF INSTALLED FIRE 3. HILTI CP 620 FIRE FOAM k is C. 1. HAZARDOUS MATERIAL REMEDIATION IS T© BE HANDLED INDEPENDENTLY FROM THIS CONTRACT. STOPS." I 2. DO NOT DISTURB HAZARDOUS MATERIALS OR ITEMS SUSPECTED OF CONTAINING HAZARDOUS MATERIALS 4. HILTI CP 675T FIRESTOP BOARD ` EXCEPT UNDER PROCEDURES SPECIFIED ELSEWHERE IN THE CONTRACT DOCUMENTS. D. REMOVED AND REINSTALLED ITEMS: G. ALL MAJOR BUILDING CODES: ICBO, SBCCI, BOCA, AND IBC. K. NON CURING, RE-PENETRABLE MATERIALS USED FOR LARGE OPENINGS AND COMPLEX PENETRATIONS MADE TO �I " 11 , 'd 3. OWNER WILL PROVIDE MATERIAL SAFETY DATA SHEETS (M.S.D.S.) FOR MATERIALS THAT ARE KNOWN TO BE 1. CLEAN CARPET TILE AND ACCESS FLOOR TO FUNCTIONAL CONDITION ADEQUATE FOR INTENDED REUSE. (NOTE TO SPECIFIER: RETAIN OR DELETE BUILDING CODES LISTED ABOVE AS APPLICABLE) ACCOMMODATE CABLE TRAYS AND BUNDLES, MULTIPLE STEEL AND COPPER PIPES, ELECTRICAL BUSWAYS IN . tP PRESENT IN BUILDINGS AND STRUCTURES TO BE DEMOLISHED BECAUSE OF BUILDING OPERATIONS OR 2. REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY WITH INSTALLATION REQUIREMENTS FOR NEW MATERIALS H. NFPA 101 - LIFE SAFETY CODE RACEWAYS, THE FOLLOWING PRODUCTS ARE ACCEPTABLE: Ii J I PROCESSES PERFORMED THERE. AND EQUIPMENT. PROVIDE CONNECTIONS, SUPPORTS, AND MISCELLANEOUS MATERIALS NECESSARY TO MAKE I. NFPA 70 - NATIONAL ELECTRIC CODE 1. HILTI FS 657 FIRE BLOCK = = -.w =` - F. STORAGE OR SALE OF REMOVED ITEMS OR MATERIALS ON-SITE WILL NOT BE PERMITTED. ITEM FUNCTIONAL FOR USE INDICATED. 1.7 QUALITY ASSURANCE 2. HILTI CP 675T FIRESTOP BOARD E. EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING L. FOR BLANK OPENINGS MADE IN FIRE-RATED WALL OR FLOOR ASSEMBLIES, WHERE FUTURE PENETRATION OF AREA OF WORK C94 G. UTILITY SERVICE: MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN SERVICE AND PROTECT THEM AGAINST A. A MANUFACTUFER'S DIRECT REPRESENTATIVE (NOT DISTRIBUTOR OR AGENT) TO BE ON-SITE DURING INITIAL PIPES, CONDUITS, OR CABLES IS EXPECTED, THE FOLLOWING PRODUCTS ARE ACCEPTABLE: DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, DAMAGE DURING SELECTIVE DEMOLITION OPERATIONS. INSTALLATION OF FIRESTOP SYSTEMS TO TRAIN APPROPRIATE CONTRACTOR PERSONNEL IN PROPER SELECTION PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION AND CLEANED AND REINSTALLED IN THEIR AND INSTALLATION PROCEDURES. THIS WILL BE DONE PER MANUFACTURER'S WRITTEN RECOMMENDATIONS 1. HILTI FS 657 FIRE BLOCK 1. MAINTAIN FIRE-PROTECTION FACILITIES IN SERVICE DURING SELECTIVE DEMOLITION OPERATIONS. ORIGINAL LOCATIONS AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE. PUBLISHED IN 'THEIR LITERATURE AND DRAWING DETAILS. 2. ALL REMOVALS OCCURRING ON THE EAST BUILDING WALLS SHALL BE X-RAYED AND MARKED PRIOR TO ANY 2. HILTI CP 6587 FIRESTOP PLUG COMMENCEMENT OF REMOVALS. ALL REMOVALS ON EAST WALL SHALL BE CAREFULLY REMOVED BY HAND. 3.6 PATCHING AND REPAIRS B. FIRESTOP SYSTEM INSTALLATION MUST MEET REQUIREMENTS OF ASTM E 814 OR UL 1479 TESTED ASSEMBLIES M. PROVIDE A FIRESTOP SYSTEM WITH A "F" RATING AS DETERMINED BY UL 1479 OR ASTM E 814 WHICH IS CAREFUL ATTENTION MUST BE ADHERED TO AS TO NOT DAMAGE THE VERIZON CENTRAL OFFICE CABLE BANKS A. GENERAL: PROMPTLY REPAIR DAMAGE TO ADJACENT CONSTRUCTION CAUSED BY SELECTIVE DEMOLITION THAT PROVIDE A FIRE RATING EQUAL TO THAT OF CONSTRUCTION BEING PENETRATED. EQUAL TO THE TIME RATING OF CONSTRUCTION BEING PENETRATED. LOCATED IN THESE WALLS. IN THE EVENT ANY REMOVALS SHOULD EXPOSE OR JEOPARDIZE THE CABLE OPERATIONS BY MECHANICS AND CRAFTSMEN SKILLED IN SUCH REPAIRS. C. PROPOSED FIRIESTOP MATERIALS AND METHODS SHALL CONFORM TO APPLICABLE GOVERNING CODES HAVING PART 3.00 - EXECUTION BANKS, ALL WORK SHALL IMMEDIATELY CEASE AND THE VERIZON NETWORK MANAGER, CONSTRUCTION LOCAL JURISDICTION. ® 7 MANAGER, AND ARCHITECT SHALL BE IMMEDIATELY NOTIFIED. B. PATCHING: COMPLY WITH DIVISION 1 SECTION CUTTING AND PATCHING. 3.1 PREPARATION " D. FIRESTOP SYSTEMS DO NOT REESTABLISH THE STRUCTURAL INTEGRITY OF LOAD BEARING A. VERIFICATION OF CONDITIONS: EXAMINE AREAS AND CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED C. REPAIRS: WHERE REPAIRS TO EXISTING SURFACES ARE REQUIRED, PATCH TO PRODUCE SURFACES SUITABLE PARTITIONS/ASSEMBLIES, OR SUPPORT LIVE LOADS AND TRAFFIC. INSTALLER SHALL CONSULT THE STRUCTURAL , FOR NEW MATERIALS UTILIZING MECHANICS AND CRAFTSMEN SKILLED IN SUCH REPAIRS. AND IDENTIFY CONDITIONS DETRIMENTAL TO PROPER OR TIMELY COMPLETION. ENGINEER PRIOIR TO PENETRATING N P ANY LOAD BEARING ASSEMBLY. PART 2.00 - PRODUCTS 11: (0) Iii U " 1. COMPLETELY FILL HOLES AND DEPRESSIONS IN EXISTING MASONRY WALLS THAT ARE TO REMAIN WITH AN 1. VERIFY PENETRATIONS ARE PROPERLY SIZED AND IN SUITABLE CONDITION FOR APPLICATION OF MATERIALS. E. FOR THOSE FIRESTOP APPLICATIONS THAT EXIST FOR WHICH NO UL TESTED SYSTEM IS AVAILABLE THROUGH A 2.1 REPAIR MATERIALS APPROVED MASONRY PATCHING MATERIAL APPLIED ACCORDING TO MANUFACTURER'S WRITTEN MANUFACTURER„ AN ENGINEERING JUDGMENT DERIVED FROM SIMILAR UL SYSTEM DESIGNS OR OTHER TESTS 2. SURFACES TO WHICH FIRESTOP MATERIALS WILL BE APPLIED SHALL BE FREE OF DIRT, GREASE, OIL, RUST, RECOMMENDATIONS. WILL BE SUBMIITTED TO LOCAL AUTHORITIES HAVING JURISDICTION FOR THEIR REVIEW AND APPROVAL PRIOR TO LAITANCE, RELEASE AGENTS, WATER REPELLENTS, AND ANY OTHER SUBSTANCES THAT MAY AFFECT PROPER A. WHEN REPAIRS MUST BE MADE IMMEDIATELY, USE REPAIR MATERIALS IDENTICAL TO EXISTING MATERIALS. IF INSTALLATION. ENGINEERING JUDGMENT DRAWINGS MUST FOLLOW REQUIREMENTS SET FORTH BY THE ADHESION. MATCHING MATERIALS ARE NOT ACCESSIBLE IMMEDIATELY, MAKE TEMPORARY REPAIRS AS NECESSARY FOR LIFE 3.7 DISPOSAL OF DEMOLISHED MATERIALS INTERNATIONAL FIRESTOP COUNCIL. 3. PROVIDE MASKING AND TEMPORARY COVERING TO PREVENT SOILING OF ADJACENT SURFACES BY SAFETY AND OPERATIONAL STATUS, AND THEEN CONDUCT PERMANENT REPAIRS WITH REPAIR MATERIALS IDENTICAL 1.8 SUBMITTALS TO EXISTING MATERIALS DURING NEW CONSTRUCTION PHASE. A. GENERAL: PROMPTLY DISPOSE OF DEMOLISHED MATERIALS LEGALLY. DO NOT ALLOW DEMOLISHED MATERIALS FIRESTOPPING MATERIALS. A/C REPLACEMENT TO ACCUMULATE ON-SITE. A. SUBMIT PRODUCT DATA: MANUFACTURER'S SPECIFICATIONS AND TECHNICAL DATA FOR EACH MATERIAL 1. IF IDENTICAL MATERIALS ARE UNAVAILABLE OR CANNOT BE USED FOR EXPOSED SURFACES, USE MATERIALS 4. COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR TEMPERATURE AND HUMIDITY CONDITIONS BEFORE, THAT VISUALLY MATCH EXISTING ADJACENIT SURFACES TO THE FULLEST EXTENT POSSIBLE. B. BURNING: DO NOT BURN DEMOLISHED MATERIALS. INCLUDING THE: COMPOSITION AND LIMITATIONS, DOCUMENTATION OF UL FIRESTOP SYSTEMS TO BE USED AND DURING AND AFTER INSTALLATION OF FIRESTOPPING. FOR CARRIER SWRM 2. USE MATERIALS WHOSE INSTALLED PERFC)RMANCE EQUAL OR SURPASSES THAT OF EXISTING MATERIALS. C. DISPOSAL: TRANSPORT DEMOLISHED MATERIALS OFF OWNER'S PROPERTY AND LEGALLY DISPOSES OF THEM. MANUFACTURER'S INSTALLATION INSTRUCTIONS TO COMPLY WITH SECTION 1300.B. MANUFACTURER'S ENGINEERING JUDGMENT IDENTIFICATION NUMBER AND DRAWING DETAILS WHEN NO UL SYSTEM 5. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 3.2 COORDINATION END OF SECTION 02070 IS AVAILABLE FOR AN APPLICATION. ENGINEERING JUDGMENT MUST INCLUDE BOTH PROJECT NAME AND PART 3.00 - EXECUTION CONTRACTOR'S NAME THAT WILL INSTALL FIRESTOP SYSTEM AS DESCRIBED IN DRAWING. A. COORDINATE LOCATION AND PROPER''SELECTION OF CAST-IN-PLACE FIRESTOP DEVICES WITH TRADE 3.1 EXAMINATION C. SUBMIT MATERIAL SAFETY DATA SHEETS PROVIDED WITH PRODUCT DELIVERED TO JOB-SITE. RESPONSIBLE FOR THE WORK. ENSURE DEVICE IS INSTALLED BEFORE PLACEMENT OF CONCRETE. 31755 MAIN RD. A. VERIFY THAT UTILITIES HAVE BEEN DISCONNECTED AND CAPPED. 1.9 INSTALLER QUALIIFICATIONS B. RESPONSIBLE TRADES TO PROVIDE ADEQUATE SPACING OF FIELD RUN PIPES TO ALLOW FOR INSTALLATION OF CUTCHOGUE, NY A. ENGAGE AN EXPERIENCED INSTALLER WHO IS CERTIFIED, LICENSED, OR OTHERWISE QUALIFIED BY THE CAST-IN-PLACE FIRESTOP DEVICES WITHOUT INTERFERENCES. B. SURVEY EXISTING CONDITIONS AND CORRELATE WITH REQUIREMENTS INDICATED TO DETERMINE EXTENT OF 3.3 INSTALLATION GROUND FLOOR SELECTIVE DEMOLITION REQUIRED. MANUFACTURFIRESTOPPINMANUFACTURER AS HAVING BEEN PROVIDED THE NECESSARY TRAINING TO INSTALL A. REGULATORY REQUIREMENTS: INSTALL FIRESTOP MATERIALS IN ACCORDANCE WITH UL FIRE RESISTANCE MANUFACTURER"S PRODUCTS PER SPECIFIED REQUIREMENTS. A MANUFACTURER'S WILLINGNESS TO SELL ITS DIRECTORY. C. INVENTORY AND RECORD THE CONDITION OF ITEMS TO BE REMOVED AND REINSTALLED AND ITEMS TO BE FIRESTOPPING (PRODUCTS TO THE CONTRACTOR OR TO AN INSTALLER ENGAGED BY THE CONTRACTOR DOES NOT TITLE: REMOVED AND SALVAGED. IN ITSELF CONFER QUALIFICATION ON THE BUYER. B. MANUFACTURER'S INSTRUCTIONS: COMPLY WITH MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION OF IT 10 DELIVERY, SO �+� D. WHEN UNANTICIPATED MECHANICAL, ELECTRICAL, OR STRUCTURAL ELEMENTS THAT CONFLICT WITH INTENDED 1. RAGE, AND HANDLING THROUGH-PENETRATION MATERIALS. 1. SEAL ALL HOLES OR VOIDS MADE BY PENETRATIONS TO ENSURE AN AIR AND WATER RESISTANT SEAL. SPECIFICATIONS FUNCTION OR DESIGN ARE ENCOUNTERED, INVESTIGATE AND MEASURE THE NATURE AND EXTENT OF CONFLICT. A. DELIVER MATERIALS UNDAMAGED IN MANUFACTURER'S CLEARLY LABELED, UNOPENED CONTAINERS, IDENTIFIED PROMPTLY SUBMIT A WRITTEN REPORT TO ARCHITECT. WITH BRAND, TYPE, AND UL LABEL WHERE APPLICABLE. 2. CONSULT WITH MECHANICAL ENGINEER, PROJECT MANAGER, AND DAMPER MANUFACTURER PRIOR TO USUALLY RETAIN BELOW. OSHA REGULATIONS REQUIRE AN ENGINEERING SURVEY BEFORE SELECTIVE DEMOLITION B. COORDINATE DELIVERY OF MATERIALS WITH SCHEDULED INSTALLATION DATE TO ALLOW MINIMUM STORAGE TIME INSTALLATION OF UL FIRESTOP SYSTEMS THAT MIGHT HAMPER THE PERFORMANCE OF FIRE DAMPERS AS IT BEGINS. AT JOB-SITE. PERTAINS TO DUCT WORK. E. ENGAGE A PROFESSIONAL ENGINEER TO SURVEY CONDITION OF BUILDING TO DETERMINE WHETHER REMOVINGC. STORE MATERIALS UNDER COVER AND PROTECT FROM WEATHER AND DAMAGE IN COMPLIANCE WITH 3. PROTECT MATERIALS FROM DAMAGE ON SURFACES SUBJECTED TO TRAFFIC. DATE: 8/16/17 ANY ELEMENT MIGHT RESULT IN STRUCTURAL DEFICIENCY OR UNPLANNED COLLAPSE OF ANY PORTION OF MANUFACTURER"S REQUIREMENTS, INCLUDING TEMPERATURE RESTRICTIONS. 3.4 FIELD QUALITY CONTROL PROJECT NO: 17-2165 STRUCTURE OR ADJACENT STRUCTURES DURING SELECTIVE DEMOLITION OPERATIONS. D. COMPLY WITH (RECOMMENDED PROCEDURES, PRECAUTIONS OR REMEDIES DESCRIBED IN MATERIAL SAFETY DATA A. EXAMINE SEALED PENETRATION AREAS TO ENSURE PROPER INSTALLATION BEFORE CONCEALING OR ENCLOSING DRAWN BY: ,JPK 3.2 UTILITY SERVICES SHEETS AS APPLICABLE. AREAS. A. EXISTING UTILITIES: MAINTAIN SERVICES INDICATED TO REMAIN AND PROTECT THEM AGAINST DAMAGE DURING E. DO NOT USE DAMAGED OR EXPIRED MATERIALS. B. KEEP AREAS OF WORK ACCESSIBLE UNTIL INSPECTION BY APPLICABLE CODE AUTHORITIES. CHECKED BY: EWS SELECTIVE DEMOLITION OPERATIONS. 1.11 PROJECT COINDITIONS C. INSPECTION OF THROUGH-PENETRATION FIRESTOPPING SHALL BE PERFORMED IN ACCORDANCE WITH ASTM E SCALE: AS NOTED B. DO NOT INTERRUPT EXISTING UTILITIES SERVING OCCUPIED OR OPERATING FACILITIES UNLESS AUTHORIZED IN A. DO NOT USE MATERIALS THAT CONTAIN FLAMMABLE SOLVENTS. 2174, "STANDARD PRACTICE FOR ON-SITE INSPECTION OF INSTALLED FIRE STOPS" OR OTHER RECOGNIZED STANDARD. WRITING BY OWNER AND AUTHORITIES HAVING JURISDICTION. PROVIDE TEMPORARY SERVICES DURING DRAWING NO: INTERRUPTIONS TO EXISTING UTILITIES, AS ACCEPTABLE TO OWNER AND TO AUTHORITIES HAVING JURISDICTION. B. SCHEDULE INSTALLATION OF FIRESTOPPING AFTER COMPLETION OF PENETRATING ITEM INSTALLATION BUT PRIOR D. PERFORM UNDER THIS SECTION PATCHING AND REPAIRING OF FIRESTOPPING CAUSED BY CUTTING OR TO COVERING OR CONCEALING OF OPENINGS. PENETRATING OF EXISTING FIRESTOP SYSTEMS ALREADY INSTALLED BY OTHER TRADES. 3.5 ADJUSTING AND CLEANING C. VERIFY EXISTING CONDITIONS AND SUBSTRATES BEFORE STARTING WORK. CORRECT UNSATISFACTORY A. REMOVE EQUIPMENT, MATERIALS AND DEBRIS, LEAVING AREA IN UNDAMAGED, CLEAN CONDITION. w"O"a AL - CONDITIONS BEFORE PROCEEDING. B. CLEAN ALL SURFACES ADJACENT TO SEALED HOLES AND JOINTS TO BE FREE OF EXCESS FIRESTOP MATERIALS A I E 600 D. WEATHER CONDITIONS: DO NOT PROCEED WITH INSTALLATION OF FIRESTOP MATERIALS WHEN TEMPERATURES AND SOILING AS WORK PROGRESSES. EXCEED THE MANUFACTURER'S RECOMMENDED LIMITATIONS FOR INSTALLATION PRINTED ON PRODUCT LABEL AND SHEET NO: 6 OF 7 PRODUCT DATA SHEET. END OF SECTION 07841 1-7 SECTION 099100 - PAINTING 4. WOOD AND WOOD DOORS : SEMI-GLOSS, WATER BASE, ACRYLIC LATEX. g. PRIMER: PREPRITE CLASSIC PRIMER, B28W101, MDF 1.6 MILS. PART 1.00 - GENERAL h. TWO FINISH COATS: PROCLASSIC WATERBORNE S-G, MDF 1.4 MILS. 1.1 SUMMARY 5. CONCRETE: SEMI-GLOSS, WATER BASE, ACRYLIC LATEX. A. SECTION INCLUDES: a. PRIMER: PROMAR INTERIOR/EXTERIOR BLOCK FILLER, B25W25; MDF 10.0 MILS. 1. SURFACE PREPARATION AND FIELD APPLICATION OF PAINTS AND FINISHES FOR INTERIOR AND EXTERIOR b. TWO FINISH COATS: PROCLASSIC WATERBORNE S-G, MDF 1.4 MILS. SURFACES. 6. FERROUS METAL: SEMI-GLOSS, WATER BASE, ACRYLIC LATEX. 2. SCHEDULE OF ITEMS TO BE PAINTED. a. PRIMER: PRO-CRYL UNIVERSAL WATER BASED PRIMER, B66-310, MDF 3.0 MILS. 3. EXTERIOR PAINTING AND FINISHING SCHEDULE. b. TWO FINISH COATS: DTM ACRYLIC S-G, B66W200; MDF 3.0 MILS. 4. INTERIOR PAINTING AND FINISHING SCHEDULE. 7. WOOD CABINETS AND WOOD SHELVES: SEMI-GLOSS, WATER BASE, ACRYLIC LATEX. B. RELATED DOCUMENTS: a. PRIMER/SEALER: PREPRITE CLASSIC LATEX PRIMER, B28W300, MDF 1.6 MILS. 1. THE CONTRACT DOCUMENTS, AS DEFINED IN SECTION 011000 - SUMMARY, APPLY TO THE WORK OF THIS b. TWOFINISH COATS: PROCLASSIC WATERBORNE S-G, MDF 1.4 MILS. SECTION. ADDITIONAL REQUIREMENT'S AND INFORMATION NECESSARY TO COMPLETE THE WORK OF THIS SECTION MAY BE FOUND IN OTHER DOCUMENTS. 8. WOOD BUMPERS: 2. SECTION 018113 - SUSTAINABLE DESIGN REQUIREMENTS a. ONE COAT: STAIN: OIL STAIN, A48 SERIES. 1.2 SUBMITTALS b. TWO COATS: CLEAR POLYURETHANE: WOODCLASSIC WATERBORNE POLYURETHANE VARNISH; A68 SERIES MDF 1.0 MIL. A. SECTION 013000 - SUBMITTAL PROCEDURES: PART 3.00 - EXECUTION 1. PRODUCT DATA: SUBMIT PRODUCT DATA FOR EACH TYPE OF PAINT SPECIFIED. a. TECHNICAL DATA SHEETS INDICATING MANUFACTURER'S CATALOG NUMBER, PAINT TYPE DESCRIPTION, AND 3.1 PREPARATION VOC CONTENT. A. DO NOT PAINT OVER DIRT, RUST, SCALE, GREASE, MOISTURE, SCUFFED SURFACES, AND CONDITIONS OTHERWISE Jacobsen & Horan b. PAINTING SCHEDULE LISTING SURFACES TO BE PAINTED WITH CROSS-REFERENCE TO THE SPECIFIC DETRIMENTAL TO FORMATION OF A DURABLE PAINT FILM, PAINTING AND FINISHING SYSTEM AND APPLICATION. IDENTIFY EACH PAINT MATERIAL BY MANUFACTURER'S B. PERFORM PREPARATION AND CLEANING PROCEDURES IN ACCORDANCE WITH PAINT MANUFACTURER'S PUBLISHED CATALOG NUMBER, GENERAL CLASSIFICATION, AND COLOR. INSTRUCTIONS FOR EACH PARTICULAR SUBSTRATE CONDITION. Engineering, P.C. 2. ASSURANCE/CONTROL SUBMITTALS: 1. PROVIDE BARRIER COATS OVER INCOMPATIBLE PRIMERS OR REMOVE AND REPRIME AS REQUIRED. 990 South 2nd Street a. TEST REPORTS: SUBMIT MANUFACTURER'S MATERIAL SAFETY DATA SHEETS (MSDS) FOR EACH PAINT TYPE 2. REMOVE HARDWARE, HARDWARE ACCESSORIES, MACHINED SURFACES, PLATES, LIGHTING FIXTURES, AND SIMILAR ITEMS SPECIFIED. IN PLACE AND NOT TO BE PAINTED OR PROVIDE SURFACE APPLIED PROTECTION PRIOR TO SURFACE PREPARATION Ronkonkoma, NY 11779 1.3 QUALITY ASSURANCE AND PAINTING OPERATIONS. REINSTALL ALL REMOVED ITEMS AFTER COMPLETION OF PAINT WORK. 0: (631) 580-6100 A. REGULATORY REQUIREMENTS: 3. CLEAN SURFACES TO BE PAINTED BEFORE APPLYING PAINT OF SURFACE TREATMENT. REMOVE OIL AND GREASE ) 1. SURFACE BURNING CHARACTERISTICS IN ACCORDANCE WITH ASTM E-84 FOR CLASS I OR A FINISH: PRIOR TO MECHANICAL CLEANING. F. (631) 580-6101 a. FLAME SPREAD (NON-COMBUSTIBLE SURFACES): LESS THAN 25. C. FERROUS METALS: CLEAN FERROUS SURFACES, THAT ARE NOT GALVANIZED OR SHOP-COATED, OF OIL, GREASE, DIRT, b. SMOKE DENSITY (NON-COMBUSTIBLE SURFACES): LESS THAN 450. LOOSE MILL SCALE AND OTHER FOREIGN SUBSTANCES BY SOLVENT OR MECHANICAL CLEANING. WWW.fhepc.Com 2. PROVIDE PAINT AND COATING MATERIALS THAT CONFORM TO FEDERAL, STATE, AND LOCAL RESTRICTIONS FOR 1. TOUCH-UP SHOP-APPLIED PRIME COATS, WHERE DAMAGED OR BARE. CLEAN AND TOUCH-UP WITH SAME TYPE VOLATILE ORGANIC COMPOUNDS (VOC) CONTENT. SHOP PRIMER. 1.4 PROJECT CONDITIONS OR SITE CONDITIONS D. GALVANIZED SURFACES: CLEAN FREE OF OIL AND SURFACE CONTAMINANTS WITH NON-PETROLEUM BASED SOLVENT. WARNING: APPLY COAT OF ETCHING PRIMER IF REQUIRED BY PAINT MANUFACTURER. IT IS A EDUCATION of NEW YORK AEp STATE EDUCATION LAW FOR ANY A. ENVIRONMENTAL REQUIREMENTS: E. CEMENTITIOUS MATERIALS: PREPARE CEMENTITIOUS SURFACES TO BE PAINTED BY REMOVING EFFLORESCENCE, CHALK, (� PERSON, UNLESS ACTING UNDER 1. APPLY PAINT FINISHES ONLY WHEN MOISTURE CONTENT OF SURFACES IS WITHIN MANUFACTURER'S DUST, DIRT, GREASE, OILS, AND BY ROUGHENING AS REQUIRED TO REMOVE GLAZE. � R J, THE DIRECTION OFA LICENSED ACCEPTABLE RANGES FOR TYPE OF FINISH BEING APPLIED. n PROFESSIONAL ENGINEER, TO 1. DETERMINE ALKALINITY AND MOISTURE CONTENT OF SURFACES TO BE PAINTED BY PERFORMING APPROPRIATE TESTS. C� ALTER AN REM ON THIS DRAWING 2. SURFACE TEMPERATURES OR SURROUNDING AIR TEMPERATURE TO BE ABOVE 40 DEGREES F BEFORE a. IF SURFACES ARE FOUND TO BE SUFFICIENTLY ALKALINE TO CAUSE BLISTERING AND BURNING OF FINISH PAINT, -% -� IN ANY WAY. IF AN ITEM IS APPLYING ALKYD FINISHES; ABOVE 45 DEGREES F FOR INTERIOR LATEX, AND 50 DEGREES F FOR EXTERIOR CORRECT CONDITION BEFORE APPLICATION OF PAINT. 6 ALTERED, THE ALTERING ENGINEER F * SHALL AFFIX TO THE ITEM LATEX WORK. MINIMUM FOR VARNISH AND TRANSPARENT FINISHES IS 65 DEGREES F. 2. NOT PAINT OVER SURFACES WHERE MOISTURE CONTENT EXCEEDS THAT PERMITTED IN MANUFACTURER'S PRINTED N HIS/HER SEAL AND THE NOTATION 3. PROVIDE CONTINUOUS VENTILATION ,AND HEATING FACILITIES TO MAINTAIN TEMPERATURES ABOVE 45 DEGREES INSTRUCTIONS. � "ALTERED BY FOLLOWED FOLLOWED BY F FOR 24 HOURS PRIOR TO, DURING AND 48 HOURS AFTER APPLICATION OF FINISHES. � pQ HIS/HER SIGNATURE AND THE 4. DO NOT APPLY PAINT IN AREAS WHERE DUST IS BEING GENERATED. 3. CLEAN FLOOR SURFACES SCHEDULED TO BE PAINTED WITH A COMMERCIAL SOLUTION OF MURIATIC ACID, OR OTHER DATE OF SUCH ALTERATION AND A ETCHING CLEANER. FLUSH FLOOR WITH CLEAN WATER TO NEUTRALIZE ACID, AND ALLOW TO DRY BEFORE PAINTING. OF NE`N SPECIFIC DESCRIPTION OF THE 5. PROVIDE LIGHTING LEVEL IN AREAS BEING PAINTED OF 80-FOOT CANDLES MEASURED MID-HEIGHT AT F. WOOD: CLEAN WOOD SURFACES TO BE PAINTED OF DIRT, OIL, AND OTHER FOREIGN SUBSTANCES WITH SCRAPERS, ALTERATION. SUBSTRATE SURFACE. MINERAL SPIRITS, AND SANDPAPER, AS REQUIRED. SANDPAPER SMOOTH THOSE FINISHED SURFACES EXPOSED TO VIEW, 1.5 MAINTENANCE AND DUST OFF. SCRAPE AND CLEAN SMALL, DRY, SEASONED KNOTS AND APPLY A THIN COAT OF WHITE SHELLAC OR CONSULTANT: A. EXTRA MATERIALS: OTHER RECOMMENDED KNOT SEALER, BEFORE APPLICATION OF PRIMING COAT. AFTER PRIMING, FILL HOLES, AND 12.1 TECHNOLOGY DRIVE, 1. PROVIDE ONE GALLON OF EACH COLOR, TYPE AND SHEEN TO CONTRACTING OFFICER. IMPERFECTIONS IN FINISH SURFACES WITH PUTTY OR PLASTIC WOOD-FILLER. SANDPAPER SMOOTH WHEN DRIED. SETAUKET, NY 11733 2. LABEL EACH CONTAINER WITH COLOR. TYPE, TEXTURE, ROOM LOCATIONS, IN ADDITION TO THE 1. PRIME, STAIN, OR SEAL WOOD REQUIRED TO BE JOB-PAINTED IMMEDIATELY UPON DELIVERY TO JOB. PRIME EDGES, MANUFACTURER'S LABEL. ENDS FACES, UNDERSIDES, AND BACKSIDES OF SUCH WOOD, INCLUDING CABINETS AND COUNTERS. ' P. 631.689.8450 PART 2.00 - PRODUCTS 2. SEAL TOPS, BOTTOMS, AND CUT-OUTS WITH A HEAVY COAT OF VARNISH OR EQUIVALENT SEALER IMMEDIATELY UPON F. 631.689.8459 "I 2.1 MANUFACTURERS DELIVERY TO JOB. ' ' A. SUBJECT TO COMPLIANCE WITH PROJECT REQUIREMENTS, MANUFACTURERS OFFERING SPECIFIED ITEMS WHICH MAY G. GYPSUM BOARD: FILL MINOR DEFECTS WITH FILLER COMPOUND. SPOT PRIME DEFECTS AFTER REPAIR. www.wfcaia.com BE INCORPORATED IN THE WORK INCLUDE THE FOLLOWING: 3.2 APPLICATION r" E 1. BENJAMIN MOORE AND COMPANY, MONTVALE, NJ (201) 573-9600. A. APPLY PAINT PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTRUCTIONS USING APPLICATION I T E C T S 2. SHERWIN-WILLIAMS COMPANY, CLEVELAND, OH (800) 321-8194. PROCEDURES APPROVED FOR THE PARTICULAR APPLICATION AND SUBSTRATE TO THE SPECIFIED MINIMUM DRY FILM B. SECTION 016000 - PRODUCT REQUIREMENTS: PRODUCT OPTIONS AND SUBSTITUTIONS. SUBSTITUTIONS: NOT THICKNESS (MDF). APPLY EACH COAT TO UNIFORM FINISH. PERMITTED. B. APPLY EACH COAT SLIGHTLY DARKER THAN PRECEDING COAT UNLESS OTHERWISE APPROVED BY CONTRACTING OFFICER. NO. DATE SUBMISSION 2.2 MATERIALS SAND LIGHTLY BETWEEN COATS TO ACHIEVE SPECIFIED FINISH. A. PAINTS: C. DO NOT APPLY FINISHES ON SURFACES THAT ARE NOT DRY. 1 10/10/17 ISSUED FOR BID 1. MANUFACTURER'S "BEST GRADE" FOR EACH TYPE SPECIFIED. D. NUMBER OF COATS AND FILM THICKNESS REQUIRED IS SAME REGARDLESS OF APPLICATION METHOD. DO NOT APPLY 2 11/02/17 ISSUED FOR FILING 2. READY-MIXED; PIGMENTS FULLY GROUND MAINTAINING A SOFT PASTE CONSISTENCY, CAPABLE OF READILY AND SUCCEEDING COATS UNTIL THE PREVIOUS COAT HAS CURED AS RECOMMENDED BY THE MANUFACTURER. UNIFORMLY DISPERSING TO A COMPLETE HOMOGENEOUS MIXTURE. E. APPLY ADDITIONAL COATS WHEN UNDERCOATS, STAINS, OR OTHER CONDITIONS SHOW THROUGH FINAL COAT UNTIL PAINT 3. PROVIDING GOOD FLOWING AND BRUSHING PROPERTIES AND BE CAPABLE OF DRYING OR CURING FREE OF FILM IS OF UNIFORM FINISH, COLOR, AND APPEARANCE. SURFACES, INCLUDING EDGES, CORNERS, CREVICES, WELDS, STREAKS OR SAGS. AND EXPOSED FASTENERS TO RECEIVE MINIMUM DRY FILM THICKNESS EQUIVALENT TO THAT OF FLAT SURFACES. 4. VOC LIMITS (G/L) FOR EXTERIOR AND INTERIOR PAINT APPLICATIONS: F. MINIMUM COATING THICKNESS: APPLY MATERIALS AT NOT LESS THAN MANUFACTURER'S RECOMMENDED SPREADING RATE. PROVIDE MINIMUM DRY FILM THICKNESS (MDF) OF THE ENTIRE COATING SYSTEM AS INDICATED IN PAINTING AND "'� • a. EXTERIOR- PAVEMENT MARKINGS FINISHING SCHEDULE AT END OF THIS SECTION. 1) EXTERIOR COAT: 150 G. BLOCK FILLERS: APPLY BLOCK FILLERS TO CONCRETE MASONRY UNITS AT RATE TO PROVIDE COMPLETE COVERAGE b. EXTERIOR- STEEL-SHOP PRIMED WITH PORES FILLED. 1) TOP COAT - NON-FLAT: 1501 H. PRIME COATS: BEFORE APPLICATION OF FINISH COATS, APPLY A PRIME COAT OF MATERIAL AS RECOMMENDED BY 2) TOP COAT - GLOSS: 250 MANUFACTURER TO MATERIAL SCHEDULED TO BE PAINTED OR FINISHED THAT HAS NOT BEEN SHOP PRIMED. RECOAT c. EXTERIOR- STEEL - GALVANIZED PRIMED AND SEALED SURFACES WHERE EVIDENCE OF SUCTION SPOTS OR UNSEALED AREAS IN FIRST COAT APPEARS, 1) PRIMER COAT: 200 TO ASSURE A FINISH COAT WITH NO BURN THROUGH OR OTHER DEFECTS DUE TO INSUFFICIENT SEALING. 2) TOP COAT - NON-FLAT: 150 I. PIGMENTED (OPAQUE) FINISHES: COMPLETELY COVER TO PROVIDE AN OPAQUE, SMOOTH SURFACE OF UNIFORM FINISH, COLOR, APPEARANCE, AND COVERAGE. CLOUDINESS, SPOTTING, LAPS, BRUSH MARKS, RUNS, SAGS, OR OTHER 3) TOP COAT - GLOSS: 250 SURFACE IMPERFECTIONS WILL NOT BE ACCEPTABLE. d. INTERIOR WOOD - TRANSPARENT J. HOLLOW METAL DOORS: PAINT EACH DOOR EDGE. 1) STAIN: 250 K. COMPLETED WORK: MATCH CONTRACTING OFFICER APPROVED FIELD SAMPLES FOR COLOR AND SHEEN. 2) VARNISH: 350 3.3 MECHANICAL AND ELECTRICAL EQUIPMENT KEY PLAN: A. REPLACE IDENTIFICATION MARKINGS ON MECHANICAL OR ELECTRICAL EQUIPMENT WHEN PAINTED OVER OR SPATTERED. L INTERIOR PLASTER, GYPSUM BOARD B. PAINT BOTH SIDES AND EDGES OF PLYWOOD BACKBOARDS FOR ELECTRICAL EQUIPMENT BEFORE INSTALLING 5) UNDERCOATER: 200 BACKBOARDS AND MOUNTING EQUIPMENT ON THEM. 6) TOP COAT - FLAT: 50 C. PREPAINT GAS PIPING PRIOR TO INSTALLATION. (TOUCH-UP PAINT AFTER INSTALLATION.) 7) TOP COAT - NON-FLAT: 150 1. COLOR: -� 8) TOP COAT - GLOSS: 150 a. ROOF (YELLOW): OSHA STANDARD "SAFETY YELLOW." b. OTHER AREAS: MATCH ADJACENT SURFACES. I j. INTERIOR INSULATED COVERINGS - CANVAS AND COTTON: N/A D. AT WORKROOM LOCATIONS, PAINT RED BACKGROUND ON WALL BEHIND FIRE EXTINGUISHER EXTENDING 6 INCHES ON -- a k. INTERIOR EXPOSED STRUCTURAL STEEL AND METAL DECK BOTH SIDES OF THE EXTINGUISHER AND FROM FLOOR TO CEILING, OR TO 12 FEET ABOVE FLOOR, WHICHEVER IS 1) INDUSTRIAL MAINTENANCE - IPRIMER: 250 LOWER. COLOR IS TO BE OSHA STANDARD "SAFETY RED" AND IN ACCORDANCE WITH ANSI Z53.1. 2) INDUSTRIAL MAINTENANCE - TOP COAT: 250 3.4 COLOR SCHEDULE I R+ B. PRIMERS AND UNDERCOATERS: MANUFACTURED BY SAME MANUFACTURER AS FINISH COAT MATERIALS. A. REFER TO PLAN FINISH SCHEDULES C. PAINT ACCESSORY MATERIALS: LINSEED OIL, SHELLAC, TURPENTINE AND OTHER MATERIALS NOT SPECIFICALLY 3.5 SCHEDULE OF ITEMS TO BE PAINTED INDICATED HEREIN BUT REQUIRED TO ACHIEVE THE FINISHES SPECIFIED OF HIGH QUALITY AND APPROVED A. PAINTED FINISHES SHALL BE PROVIDED FOR, BUT NOT LIMITED TO, THE FOLLOWING ITEMS. REFER TO DRAWINGS AND • MANUFACTURER. PAINT COLOR SCHEDULE AT END OF THIS SECTION FOR DESIGNATED FINISHES AND COLORS OF AREAS. 2.3 EXTERIOR PAINT SYSTEMS 1. EXTERIOR: ALL EXTERIOR SURFACES INCLUDING, BUT NOT LIMITED TO: "7 a. HOLLOW METAL DOORS AND FRAMES. � 6 ��f��✓ " A. BENJAMIN MOORE; b. METAL OPENING FRAMES AND TRIM. 1. FERROUS METAL: SEMI-GLOSS, WATER BASE, ALKYD PRIMER/ACRYLIC LATEX. c. METAL FLASHING (IF EXPOSED FROM GROUND LEVEL) AND DOWNSPOUT. a. PRIMER: M04 ACRYLIC METAL IPRIMER; MDF 2.0 MILS. d. METAL GRAVELSTOPS (VERTICAL FACE). AREA OF WORK b. EACH FINISH COAT: M29 DTM ,ACRYLIC SEMI-GLOSS; MDF 2.0 MILS. e. PIPE BOLLARDS, IF NOT TO RECEIVE PLASTIC COVERS SPECIFIED IN SECTION 05500. QN 2. GALVANIZED METAL: SEMI-GLOSS, VIVATER BASE, ALKYD PRIMER/ACRYLIC LATEX. f. METAL RAILINGS. g. ROOF HATCH. a. PRIMER: M04 ACRYLIC METAL PRIMER; MDF 2.0 MILS. h. CANOPY SUPPORTING STEEL STRUCTURE. b. EACH FINISH COAT: M29 DTM ,ACRYLIC SEMI-GLOSS; MDF 2.0 MILS. L WALL LOUVERS. 3. COMPOSITE MATERIALS: 2. INTERIOR: ALL INTERIOR SURFACES AS SCHEDULED ON DRAWINGS INCLUDING, BUT NOT LIMITED TO: a. PRIMER: 169 SUPER SPEC LATEX EXTERIOR PRIMER. a. HOLLOW METAL DOORS AND FRAMES. b. EACH FINISH COAT: 170 SUPER SPEC LATEX HOUSE AND TRIM PAINT b. HOLLOW METAL WINDOW FRAMES. n. B. SHERWIN-WILLIAMS: c. METAL OPENING FRAMES AND TRIM. 1. FERROUS METAL: SEMI-GLOSS, LOW VOC, ALKYD PRIMER/ACRYLIC LATEX. d. HOLLOW METAL WINDOW FRAMES. .: a. PRIMER: PRO-CRYL UNIVERSAL WATER-BASED PRIMER, B66-310, MDF 3.0 MILS. e. METAL OPENING FRAMES AND TRIM. b. EACH FINISH COAT: DTM ACRYLIC B66 SERIES; MDF 3.0 MILS. f. GYPSUM WALLBOARD. 2. GALVANIZED METAL: SEMI-GLOSS, WATER BASE, ALKYD PRIMER/ACRYLIC LATEX. g. EXPOSED CONCRETE UNIT MASONRY. a. PRIMER: PRO-CRYL UNIVERSAL WATER BASED PRIMER, B66-310, MDF 3.0 MILS. h. PIPE BOLLARDS. b. EACH FINISH COAT: DTM ACRYLIC B66 SERIES; MDF 3.0 MILS. i. METAL RAILINGS. 3. SIMILAR TO ITEM 2.3.A.3. j. EXPOSED STRUCTURE COLUMNS. 2.4 INTERIOR PAINT SYSTEMS - REFER TO FINISH SCHEDULE k. METAL STAIR STRINGERS AND HANDRAILS. c. THE FOLLOWING IS TO BE USED IF NOT SPECIFIED ON THE DRAWING FINISH SCHEDULES - CONTRACTOR I. EXPOSED WOOD AND WOOD TRIM. ASC REPLACEMENT TO SUBMIT PRIOR TO INSTALLING ANY PAINTED FINISH. B. DO NOT PAINT THE FOLLOWING ITEMS: p (� A. BENJAMIN MOORE: 1. PRE-FINISHED ITEMS: FOR CARRIER S V V c`/�/n RM 1. GYPSUM BOARD: EGGSHELL, WATER BASE, ACRYLIC LATEX. a. ALUMINUM, BRASS, BRONZE, STAINLESS STEEL, AND CHROME PLATED STEEL. a. PRIMER: 284 MOORECRAFT SUIPERHIDE INTERIOR LATEX PRIMER/UNDERCOATER; MDF 1.5 MILS. b. PRE-FINISHED ITEMS, SUCH AS TOILET COMPARTMENTS, ACOUSTICAL CEILING MATERIALS, MECHANICAL, AND b. EACH FINISH COAT: MOORECRAFT SUPER-HIDE EGGSHELL 286. ELECTRICAL EQUIPMENT. 2. MASONRY: EGGSHELL, WATER BASE, ACRYLIC LATEX. c. UL, FM, AND OTHER CODE-REQUIRED LABELS. a. PRIMER: MOORECRAFT SUPER (HIDE INTERIOR/EXTERIOR LATEX BLOCKFILLER 285; MDF 4.0 MILS. d. EQUIPMENT IDENTIFICATION, PERFORMANCE RATING, AND NAME PLATES. b. EACH FINISH COAT: MOORECRAFT SUPER-HIDE EGGSHELL 286. e. FINISH HARDWARE. 31755 MAIN RD. 3. METAL: SATIN, WATER BASE, ACRYLIC LATEX. f. FACTORY FINISHED METAL WALL PANELS, METAL WALL PANEL TRIM, AND METAL GRAVEL STOPS. CUTCHOGUE, NY EACH FINISH COAT: MOORECRAFT SUPER-HIDE EGGSHELL 286. 2. EXPOSED ITEMS: 4. WOOD AND WOOD DOORS : SATIN„ WATER BASE, ACRYLIC LATEX. a. EXPOSED MECHANICAL DUCTWORK, HANGERS, AND SUPPORTS. GROUND FLOOR a. PRIMER: 253 MOORECRAFT LATEX ENAMEL UNDERCOATER AND PRIMER SEALER; 2.0 MILS. b. EXPOSED PIPING AND CONDUIT, HANGERS AND SUPPORTS. b. EACH FINISH COAT: MOORECRAFT SUPER-HIDE EGGSHELL 286. c. EXPOSED FIRE PROTECTION PIPING, HANGERS AND SUPPORTS. TITLE: 5. CONCRETE: SEMI-GLOSS, WATER BASE, ACRYLIC LATEX. d. EXPOSED ROOF STRUCTURE. a. PRIMER: MOORECRAFT SUPER HIDE INTERIOR/EXTERIOR LATEX BLOCKFILLER 285; MDF 4.0 MILS. e. EXPOSED ROOF DECK. b. EACH FINISH COAT: 276 MOORECRAFT ACRYLIC LATEX; MDF 1.5 MILS. 3.6 PAINTING AND FINISHING SCHEDULE (U.O.N. ON THE CONTRACT DRAWING FINISH SCHEDULE) • SPECIFICATIONS 6. FERROUS METAL: SEMI-GLOSS, WATER BASE, ACRYLIC LATEX. A. INTERIOR PAINT SYSTEMS: a. PRIMER: M04 ACRYLIC METAL PRIMER; MDF 2.0 MILS. 1. INTERIOR GYPSUM WALLBOARD: b. EACH FINISH COAT: 276 MOORECRAFT ACRYLIC LATEX; MDF 1.5 MILS. a. 1 COAT LATEX WALL PRIMER. 7. WOOD CABINETS AND WOOD SHELVES: SEMI-GLOSS, WATER BASE, ACRYLIC LATEX. b. 1 COAT LATEX EGGSHELL ENAMEL a. ENAMEL UNDERCOATER: MOORECRAFT ACRYLIC LATEX UNDERBODY 269. 2. INTERIOR MASONRY: DATE: 8/16/17 b. EACH FINISH COAT: 276 MOORIECRAFT ACRYLIC LATEX; MDF 1.5 MILS. a. 1 COAT LATEX BLOCK FILLER PROJECT NO: 17-2165 8. WOOD BUMPERS: b. 1 COAT LATEX EGGSHELL ENAMEL a. STAIN: 234 BENWOOD PENETRATING STAIN. 3. INTERIOR METAL: DRAWN BY: JPK b. BENWOOD STAYS CLEAR ACRYLIC; POLYURETHANE: 423 BENWOOD LOW LUSTRE POLYURETHANE. a. 2 COATS LATEX SATIN c. BENWOOD STAYS CLEAR ACRYLIC, PLYURETHANE: 422 BENWOOD HIGH-GLOSS POLYURETHANE. 4. INTERIOR WOOD (PAINTED): CHECKED BY: EWS B. SHERWIN WILLIAMS: a. 1 COAT ENAMEL UNDERCOAT SCALE: AS NOTED 1. GYPSUM BOARD: LOW VOC, EG-SHELL, WATER BASE, ACRYLIC LATEX. b. 2 COATS ALKYD SEMI-SATIN ENAMEL a. PRIMER: HARMONY LATEX PRIMER, MDF 1.6 MILS. 5. CAST-IN-PLACE CONCRETE: DRAWING NO: b. TWO FINISH COATS: HARMONY LATEX EG-SHEL, MDF 1.6 MILS. a. ONE COAT OF LATEX MASONRY BLOCK FILLER. 2. MASONRY: SEMI-GLOSS, WATER BASE, ACRYLIC LATEX. b. TWO TINTED COATS OF ACRYLIC LATEX 22"02 0() a. PRIMER: PREPRITE MASONRY PRIMER, 828W300, MDF 1.1 MILS. SEMI-GLOSS ENAMEL. b. TWO FINISH COATS: 6. WOOD DOORS - PAINTED. 3. METAL: SEMI-GLOSS, WATER BASE, ACRYLIC LATEX. a. ONE COAT ENAMEL UNDERCOAT. a. TWO FINISH COATS: DTM ACRYLIC S-G, B66W200; MDF 3.0 MILS. b. TWO TINTED COATS OF LATEX SHEET NO: 7 OF 7 WOOD AND WOOD DOORS : SEMI-GLOSS, WATER BASE, ACRYLIC LATEX. SEMI-GLOSS ENAMEL. END OF SECTION ' MECHANICAL LEGEND SECTION DESIGNATION MECHANICAL ABBREVIATIONS NOTES: A AMPERES F&T FLOAT AND THERMOSTATIC R RISE 1. ALL EQUIPMENT IS NEW UNLESS OTHERWISE NOTED. -�-� SUPPLY REGISTER, OR SHEET N0. WHERE SECTION IS SHOWN 2. (E)- ADJACENT TO EQUIPMENT DENOTES EXISTING TO REMAIN. SUPPLY GRILLE AC AIR CONDITIONING UNIT FA FREE AREA (SQ.FT.) RA RETURN AIR 3. (R)- ADJACENT TO EQUIPMENT DENOTES EXISTING TO BE RELOCATED. ACC AIR COOLED CONDENSER FB FLAT ON BOTTOM RD ROUND 4. (D)- ADJACENT TO EQUIPMENT DENOTES EXISTING TO BE DEMOLISHED. RETURN REGISTER, OR 1110. NEW PIPE WITH DIRECTION OF FLOW ACCU AIR COOLED CONDENSING UNIT FC FLEXIBLE CONNECTION REFR REFRIGERANT DEMOLITION TO INCLUDE ALL DUCTWORK, PIPING, CONTROLS, SUPPORTS, HANGERS, BASES, ETC. BACK TO SOURCE. RETURN GRILLE AHU AIR HANDLING UNIT FD FIRE DAMPER, FLOOR DRAIN RESP REMOTE ENVIRON. SENSOR PNL. - - - COLD WATER PIPING AD ACCESS DOOR FF FINAL FILTER RF RETURN FAN -- LOUVER & SCREEN AFF ABOVE FINISHED FLOOR FIN FL FINISHED FLOOR RG RETURN GRILLE ARF ABOVE RAISED FLOOR FLA FULL LOAD AMPERES RR RETURN REGISTER DUCTWORK - NEW HOT WATER PIPING —� LINEAR DIFFUSER BG BOTTOM GRILLE FPM FEET PER MINUTE RM ROOM Jacobsen & Horan BHP BRAKE HORSEPOWER FPS FEET PER SECOND RPM REVOLUTIONS PER MINUTE - - - - -- HOT WATER RETURN PIPING BOD BOTTOM OF DUCT FR FLOOR REGISTER SA SUPPLY AIR — — — —— —— 10x6 SR 10" BY 6" SUPPLY REGISTER, BR BOTTOM REGISTER FSD FIRE/SMOKE DAMPER SAN SANITARY Engineering, P.C. — —————— DUCTWORK - EXISTING TO REMAIN (150 990 South 2nd Street ) 150 CFM SUPPLY AIR SAN SANITARY PIPING BTU BRITISH THERMAL UNIT FT FLAT ON TOP, FEET SD SUPPLY DIFFUSER 779 Y 1 N 1 BTUH BTU PER HOUR FV FACE VELOCITY SF SUPPLY FAN O: (631) 580-6100 Ronkonkoma,, N1 CC COOLING COIL GALV GALVANIZED SG SUPPLY GRILLE F: (631) 580-6101 10x6 RG 10" BY 6" RETURN GRILLE GRS GREASE PIPING CD CEILING DIFFUSER GC GENERAL CONTRACTOR SOD SIDE OF DUCT : (63 j) 580- 10 � 150 CFM RETURN AIR 7_1ZZZZA_1' (-150) CF CUBIC FEET H&R HOSE & REEL SP STATIC PRESSURE LL11 LL1111U� DUCTWORK - EXISTING TO BE REMOVED - —— — — — — ———- VENT PIPING CFM/(XXX) CUBIC FEET PER MINUTE HGT HEIGHT SPEC SPECIFICATION �F NE►%V�'` �'�G �WI1171 1110 ; SR SUPPLY REGISTER �H J. y O IT ISA VIOLATION OF NEW YORK CG CEILING GRILLE HP HORSEPOWER � y � STATE EDUCATION LAW FOR ANY MJF' O PERSON, UNLESS ACTING UNDER CHWR CHILLED WATER RETURN HR HOUR SST STAINLESS STEEL '� THE DIRECTION OF A LICENSED GLY GLYCOL PIPING co �!/ 9 PROFESSIONAL ENGINEER, TO —— — — —— CHWS CHILLED WATER SUPPLY HZ FREQUENCY T THROAT * ALTER AN ITEM ON THIS DRAWING - - - -- -- VANED ELBOW Z`•y IN ANY WAY. IF AN ITEM IS ALTERED, THE ALTERING ENGINEER CLG CEILING IN INCH OR INCHES TEMP TEMPERATURE r-, '� SHALL AFFIX TO THE REM DUCTWORK - NEW WITH ACOUSTIC LINING RL REFRIGERANT LIQUID LINE � _ HIS/HER SEAL AND THE NOTATION COND CONDENSATE IPS IRON PIPE SIZE TG TRANSFER GRILLE ALTERED BY" FOLLOWED BY FO �735�13 HIS/HER SIGNATURE AND THE -——— ———— - CR CEILING REGISTER KW KILOWATT TO TRANSFER OPENING �' NPS'. ` SDATE PECIFIC SUCHDESCATERNATIION AND A VANED ELBOWCU COPPER ' OF THE UFESS_". ` ALTERATION. RS REFRIGERANT SUCTION LINE KWH KILOWATT-HOUR TOD TOP OF DUCT DUCT UNDER POSITIVE PRESSURE CWR CONDENSER WATER RETURN LAT LEAVING AIR TEMPERATURE TR TOP REGISTER CONSULTANT: (SUPPLY AIR OR FAN DISCHARGE) CWS CONDENSER WATER SUPPLY LBS POUNDS TF TRANSFER FAN 12-1 TECHNOLOGY DRIVE, VANED OR RADIUS ELBOW RHG REFRIGERANT HOT GAS SETAUKET, NY 11733 D DROP, DRAIN LDB LEAVING DRY BULB TEMP TV TURNING VANES47, P. 631.689.8450 � \ DB DRY BULB LF LINEAR FEET TYP TYPICAL F. 631.689.8459 \ '" www.wfcaia.com DUCT UNDER NEGATIVE PRESSURE c CONDENSER WATER SUPPLY DIA DIAMETER LPC LOW PRESS CONDENSATE TX TOILET EXHAUST o. (RETURN, EXHAUST OR OUTSIDE AIR) SMOOTH RADIUS ELBOW DMPR DAMPER LPS LOW PRESS STEAM UH UNIT HEATER DN DOWN LWB LEAVING WET BULB TEMP UON UNLESS OTHERWISE NOTED I T E C T S CR CONDENSER WATER RETURN .. .. DWG DRAWING LWT LEAVING WATER TEMP V VOLTS NO. DATE SUBMISSION VD VOL PER DWV DRAIN WASTE VENT MAX MAXIMUM VENT VENTILATION AIR FD CH CHILLED WATER SUPPLY 1 10/10/17 ISSUED FOR BID (FSD) RE-�� STEAM RADIATOR DX DIRECT EXPANSION MBH THOUSAND BTU PER HOUR VT VENT FIRE DAMPER (W/ACCESS DOOR) Eo ELECTRIC BASEBOARD RADIATOR EA EXHAUST AIR MC MECHANICAL CONTRACTOR VTR VENT THROUGH ROOF 2 11/02/17 ISSUED FOR FILING FSD = COMBINATION FIRE/SMOKE DAMPER CHR CHILLED WATER RETURN EAT ENTERING AIR TEMPERATURE MD MOTORIZED DAMPER W WIDTH —® VERT. POS. EC ELECTRICAL CONTRACTOR MHP MOTOR HORSEPOWER W/ WITH —® HOR. POS. FLEXIBLE DUCT EXISTING PIPING TO BE REMOVED EDB ENTERING DRY BULB TEMP MIN MINIMUM W/0 WITHOUT EDH ELECTRIC DUCT HEATER MTR MOTOR WAC WINDOW A/C UNIT - � OR AUTOMATIC DAMPER (ELECTRIC) EDR ELECTRIC DIRECT RADIATION NC NORMALLY CLOSED WB WET BULB M FLEXIBLE PIPE CONNECTION EF EXHAUST FAN NIC NOT IN CONTRACT WC WATER COLUMN SD AUTOMATIC SMOKE DAMPER DUCT FLEXIBLE CONNECTION `-� PIPE DROP (IN DIRECTION OF FLOW) ELEV ELEVATION NO NORMALLY OPEN, NUMBER WG WATER GAUGE �► EL ELECTRIC NPT NATIONAL PIPE THREAD WMS WIRE MESH SCREEN RISEOD END OF DUCT NTS NOT TO SCALE EQ IN DUCTWORK (IN DIRECTION OF AIR FLOW) J—. PIPE RISE (IN DIRECTION OF FLOW) EQ EQUAL OA OUTSIDE AIR Ell EUH ELECTRIC UNIT HEATER ON OUTSIDE AIR INTAKE KEY PLAN: DROP IN DUCTWORK (IN DIRECTION OF AIR FLOW) —H-� x PITCH UP IN DIRECTION OF FLOW EWB ENTERING WET BULB OAF OUTSIDE AIR FAN I VERTICAL DUCT DROP EWT ENTERING WATER TEMP OBVD OPPOSED BLADE VOL. DAMPER CENTER LINE L --B-i PITCH DOWN IN DIRECTION OF FLOW EXH EXHAUST OD OUTSIDE DIAMETER f EWH ELECTRIC WATER HEATER OV OUTLET VELOCITY I? F FILTER PD PRESSURE DROP ......... DIAMETER I UNION I: 'F DEGREES FAHRENHEIT PF PREFILTER a x LOUVER IN DOOR - MIN. 1.0 SF FREE AREA I 1.0 F.A. VERTICAL DUCT RISE CONCENTRIC REDUCER UNDERCUT DOOR ACCEPTANCE TESTING ECCENTRIC REDUCER - FLAT BOTTOM E Q PRIOR TO FINAL ACCEPTANCE, THE MECHANICAL CONTRACTOR SHALL T THERMOSTAT (ELECTRONIC, PNEUMATIC) POINT OF CONNECTION SCHEDULE THE FOLLOWING TESTS ON THE MECHANICAL EQUIPMENT. TESTING ARTA OF WORK ECCENTRIC REDUCER - FLAT TOP TO BE PERFORMED DURING PUNCH OUT. THE MECHANICAL CONTRACTOR, rg� CONTROLS VENDOR AND WATCH ENGINEER SHALL BE PRESENT DURING THE © CONTROLLER, TEMPERATURE FOLLOWING TESTS: POINT OF DISCONNECTION O REFRIGERANT SIGHT GLASS 1. PUMP AUTO CHANGEOVER CD-1 TYPE 1 CEILING DIFFUSER DUCT SMOKE DETECTOR 2. LOW GLYCOL ALARM ® (400) (SEE AIR DEVICE SCHEDULE) DS DS = SUPPLY DUCT 3. HIGH HEAD PRESSURE ALARM 400 CFM SUPPLY AIR DR = RETURN DUCT UNIT HEATER OR PROP TYPE WALL FAN 4. LEAK DETECTION ALARMS zRR RG)-1 TYPE 1 RETURN REGISTER/RETURN GRILLE FIRESTAT 5. BREAK GLASS (-300) (SEE AIR DEVICE SCHEDULE) ® ACCESS DOORS, VERT OR 6. GPNOC VERIFICATION: 300 CFM RETURN AIR El— FREEZESTAT 6.1. COMMON ALARM HORIZONTAL 6.2. LEAK DETECTION ALARM RECTANGULAR DIFFUSER (3-WAY, 2-WAY) 6.3. HI/LO SPACE TEMPERATURE ALARM A/C REPLACEMENT FS FLOW SWITCH FT TRANSITION (FLAT TO)P) FOR CARRIER SWRM FLOOR DRAIN / FLOOR SINK VIBRATION ISOLATOR IN HANGER 0x10 �_215x8 (FB = FLAT BOTTOM;) OUTSIDE AIR VENTILATION SCHEDULE 0-E- HOSE BIBBSTANDARD BRANCH SUPPLY OCCUPANCY CLASS B - TELEPHONE EXCHANGE 31755 MAIN RD. TP TRAVERSE POINT S R OR RETURN NO SPLATTER CUTCHOGUE, NY SPACE CRITERION VARIABLE REQUIRED PROVIDED GROUND FLOOR SWITCHROOM, POWER 0.06 CFM/F72 4,342 F72 TITLE: 261 300 ROOM & FRAME WARRANTY VENTILATION NOTE SHOP DRAWINGSOFFICE, BREAK 5 CFM/PERSON + 0.06 7 PEOPLE, 625 FT2 LEGEND, ABBREVIATIONS & NOTES ALL WORK SHALL BE GUARANTEED AGAINST DEFECTS FOR A PERIOD OF ONE THE MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE GC TO FURNISH WITHIN THE FIRST WEEK AFTER THE CONSTRUCTION KICK-CFF MEETING, THE ROOM CFM/FT2 73 100 YEAR FROM DATE OF FINAL ACCEPTANCE OF THE INSTALLATION AND ANY AND INSTALL PEDESTAL AND BOX SMOKE EATER-TYPE FANS FOR AIR EXHAUST MECHANICAL CONTRACTOR SHALL PREPARE AND SUBMIT TO THE ENGINEER DATE: 8/16/17 PORTIONS OF THE WORK WHICH DEVELOP DEFECTS DURING THAT TIME SHALL TO BUILDING EXTERIOR DURING ALL PIPE-BRAZING AND TORCH WORK VIA FLEX FOR APPROVAL THE FOLLOWING EQUIPMENT/SYSTEMS. NOTE THAT ELECTRONIC CORRIDOR 0.06 CFM/FT2 418 FT2 26 50 BE REPLACED OR REPAIRED IN A MANNER SATISFACTORY TO THE TENANT OR DUCT AS NECESSARY; PROPER VENTILATION TO BE MAINTAINED AT ALL TIMES; PDF FORMAT IS THE PREFERRED SUBMISSION. CONTRACTOR SHALL INDICATE PROJECT NO: 17-2165 OWNER. INCLUDE ANY NECESSARY ELECTRICAL CONNECTIONS, EXTENSION CORDS, ETC.; COMPLETE MODEL NUMBERS AND INCLUDED ACCESSORIES ON THE CATALOG 2 2 DRAWN BY: ALL COMPRESSORS SHALL BE GUARANTEED AGAINST DEFECTS FOR A PERIOD EAB CIRCUIT REQUIREMENTS ARE ASSUMED AS 120V, 1 P/20A. CUT SHEETS: STORAGE 0.12 CFM/FT 240 FT 29 50 OF FIVE YEARS FROM DATE OF FINAL ACCEPTANCE OF THE INSTALLATION. ANY 1. ALL NEW EQUIPMENT (AIR-CONDITIONING EQUIPMENT, VALVES, FITTINGS, CHECKED BY: KJH / PEJ DEFECTS OF THE COMPRESSOR WHICH DEVELOP DURING THAT TIME SHALL BE PIPE SUPPORTS, CONTROL DEVICES, ETC.) 1. VENTILATION COMPLIES WITH CHAPTER 4 OF THE 2015 INTERNATIONAL MECHANICAL CODE & CHAPTER 12 OF THE SCALE: NONE REPLACED OR REPAIRED IN A MANNEIR SATISFACTORY TO THE TENANT OR 2. AUTOCAD-GENERATED PIPING LAYOUT DRAWINGS . 2015 INTERNATIONAL BUILDING CODE AS AMENDED BY NY STATE. OWNER. 3. AUTOCAD-GENERATED DUCTWORK SHEET METAL DRAWING(S). ( ) 2. MINIMUM OUTDOOR AIR QUANTITIES ARE PROVIDED TO THE SPACE BY OUTSIDE AIR FAN 341-01-01. DRAWING NO: 4. CONTROL WIRING DIAGRAMS WITH WRITTEN SEQUENCE OF OPERATIONS. SHOULD ANY ISSUES OCCUR ON SITE DURING CONSTRUCTION OR DURING THE WARRANTY PERIOD, THE CONTRACTOR SHALL BE HELD TO A FOUR (4) HOUR TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL RESPONSE TIME. THE CONTRACTOR MIDST BE ON SITE WITHIN FOUR (4) [A 0 0 0 0 HOURS TO ADDRESS THE ISSUE. JUDGMENT, THESE PLANS AND SPECIFICATIONS ARE IN COMPLIANCE SHEET NO: 1 OF 9 WITH THE 2015 IECC AS AMENDED BY NEW YORK STATE. (-500) (-500) r------I------------------------r........ �L-1 ._ ..._. _....... _ - .... _ _� _ ---------- 4- + .......--_..- __� �.-1 � _ - r�•- � _ _. �...._ _ ��-.� _ __.._ .._r ._ 339- 1-01 _ 339 -01` 24x12n, TG v 1 E DC POWER ROOM COMP .... EHY. M I txCOMP _.:.� DC POWER ROOM I DEHY _ 3 13 TG)i`JTG� ry COGB r i - ` - . -' i� 1 ......------ _..... - I a .... a s. ::36x14ffi f .c .... awn eu�rx �� xawo m _ exw .�� n��� \ E Jacobsen & Horan a. ... DIG. C. W E_, 990gSouthr2nd�Street i , i 5ESS DIG. SW. _� - R 9 � �'- Ronkonkoma, N 7 ,__... __ __ a �.. _.. 4 rn BATS o 0: (631) 580-6100 �, .. �. i + F: 631 580 61 } I! EMG. ENGINE RM. _. ... . ::_... .µ�..� w. : �.�. : , �-::.-.-- -:.-:-.:.m m...� ��....� �..,��,�w M�W�. EMG. ENGINE RM. ( ) : }} .. 2 s I ... � T ....._ ... 21 i, WI 3 r... I{ t :a BOILER RM <_..____.;,._ } BOILER R M -------_,.. L : N E IT IS A VIOLATION OF NEW YORK J € x ,. 19 14 1 0 ; 315- � 23 O W � O _... _._. _.._. .... Fi' °�:, ` / STATE EDUCATION LAW FOR ANY IJ M x 01-02 330- i '° �� �A H J• NO PERSON, UNLESS ACTING UNDER -' 1 5 �� .Q THE DIRECTION OF A LICENSED I ,. ;;:-• W - .. -....._ - ..._-.. ...... __.._ .. __.__... .... 16 Q' - -71 315- I.01-0.... E -v PROFESSIONAL ENGINEER. TO ' _ _ .. __...... ..•:_. . _. _. _. _. T :. r_ 7_..E.{ 'L ALTER AN ITEM ON THIS DRAWING IJ _...._ .. - .........- ....... _.� II. ._._ i ._1.__d � 01-01 * �..� IN ANY WAY. IF AN ITEM IS I >' 5ESS/TOLL j -- u_ 22 � ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM ...... ....... ........ ........ ..................... .......... ,i... !i �' '�' -,, 4l HIS HER SEAL AND THE NOTATION STO R ER M 'X� �2 'ALTERED BY" FOLLOWED BY i;: �.�c - -----ns rax ax�, - ^ �/1 x. �" ' mew a.. �... amu. x��.• . �� amer '4 E ;. € q 1 s€ I jam" .:.� �� HIS/HER SIGNATURE AND THE il k : ��.:�I Z. .......... ........ G..<� �.......----....-.-- --- .....---•- .•• --'-. _'-- . : .. ... ._ DAE OF SUCH ALTERATION AND A , E -.. =E; „ "" ;, p X735 �. SPECIFIC DESCRIPTION Or THF 5ESS TOLL + P 5ESS MTCE. CTR. / E �D 5ESS MTCE. CTR. , ; ' .X ISTORERM �... � � . ........ ........ ....... .. . . ._..�....... , . OfiESS10N ALTERATION. : 3 � c E 3 I ' FID L ---- �`;r � ,; � /� /"� I 12-1 TECHNOLOGY DRIVE . M.E.R. •• � ( I ':`� � + �,'`/�: -�=. � is SETAUKET NY 11733 i 7 2 6 , L ��� _ I a M J - � o `!Ori',. .: 3 I � � " / -- x �r '� P. 631.689.8450 4 I E f F. 631.689.8459 } www.wfcaia.com ? E }_ I'� rl. I T E C T S �? = F .E I - € .� ...;...� ��.',':�/, :�`;� �}. NO. DATE SUBMISSION ..................... ....._..T.......,..T:mom::� :m::��__'"�� i.....,....:. _._. .....3_.. 3, ""'�`�"""' S S�F..`r ..,...i _•,.•,._.. m ' --- E '• � '' --� � .� Ell1 10/10/17 ISSUED FOR BID CARRIER EQ PT. `_ `� -- - I ', CARRIER EQ PT. _ I i. 2 11/02/17 ISSUED FOR FILING : C O _.- __ i � � C _ IS ..:. _.._ ..... _ � C� .. i _:..� 1 C�: .:�.._.�...r•_.:_ I_._-......I._._._.._ � �.'S R .. .. i TOR LOCKER & E.. _ �, � � _. TO E LOUNGE _.._ ...._ � ����.�� � ���• ,.... _....... _. �:��::�w...._....,_...._._ .... .._.. �...��_._,} �f � � � LOCKER & _ +` .......... i ` .....,....3..........�.f.........m.:=I } ______. ... ....«.... ..I L�w�w.���... ....�,�.�....t��...._.�_.-..,_��........._.._�_.._�.:~.,.,_....,....t_..�._�..�............_e�._.....� i_..,'1 V.`.I.._.F�. E.........._.� W.,...._I,...,.•_.•....,i? r� _..._,a+ O U ........... :.- 0 L ...L 18 18 } IJ I 3 �.. _+ } } MDF ' UNI X TLT MDF UNIX TLT. �_ _ :. .- I [..._._._, KEY PLAN: �..`y TEMPORARY SPOT COOLING DEMOLITION KEY NOTES O 7 (`.142'X2© / / f W THE MECHANICAL CONTRACTOR SHALL COORDINATE WITH JAMES DILLON, PROPERTY MANAGER, TO 1. DEMOLISH STACKED 25-TON AND 20-TON 12. DEMOLISH MOTORIZED ACTUATOR IN EXISTING , ,• ./ ' •'' /// T AND A 4 - COOLERS AS NECESSARY TO PROVIDE T- '' /`� TRANSPORT INSTALL FOUR 5 TON EA. SPOT CARRIER BUILT-UP AIR HANDLING UNITS =�' ,�` � ,� ` O ( ) SUPPLY AIR DUCT. VOLUME DAMPER TO -- _. _._ TEMPORARY COOLING TO THE EXISTING SWITCHROOM. MODEL 39ED36/ 39ED29, AND ASSOCIATED REMAIN AND BE RE-USED FOR BALANCING. r ......�... .. .._._._.__......_...._..... .. � •,,,��„ � REFRIGERANT PIPING, HOT WATER SUPPLY AND . f THE MC SHALL INCLUDE THE COST TO PICK-UP AND DELIVER COOLERS TO THE SITE, CONNECT RETURN PIPING, AND CONTROL WIRING AND 13. DEMOLISH TRANSFER GRILLE. GC TO PATCH 11 M+ 6 CONDENSER AIR DUCTWORK, CONDENSATE PIPING AS WELL AS MAINTAIN COOLERS THROUGHOUT CONDUIT BACK TO SOURCE. RECLAIM R-22 AND SEAL WALL. I+//,/. / THE PROJECT. REFRIGERANT PRIOR TO CIUTTING PIPES. f M.E.R. ``'',�` 649- i+ 8 ARFA OF WORK COOLERS BASED ON OCEAN-AIRF, MODEL PAC6032. 14. DEMOLISH THERMOSTAT FOR SPACE AND ALL Ld --- -•• / 01-01 2. DEMOLISH RETURN AIR FAN IN MER AND ASSOCIATED CONDUIT AND WIRING. -� ASSOCIATED INSULATED RETURN AIR DUCTWORK I %, - APPROXIMATE COOLER LOCATIONS ARE SHOWN ON THIS PLAN. WITHIN THE MER. 15. DEMOLISH DEHUMIDIFIERS, 315-01 01 AND 315-01-02, AND ASSOCIATED CONTROL CONDENSATE WATER SHALL BE MECHANICALLY PUMPED INTO THE FLOOR DRAIN IN THE MER. 3. DEMOLISH INSULATED MIXED AIR PLENUM AND PANEL, PIPE SUPPORTS, DUCT FEED TUBE / /,,''",, ,r'/` '/// 'r 5 r / / � ' . ASSOCIATED INSULATED OUTSIDE AIR AND DOMESTIC COLD WATER PIPING BACK TO HOT CONDENSER AIR SHALL BE DUCTED (USING INSULATED FLEXIBLE DUCT) TO A NEW TEMP. DUCTWORK, MOTORIZED DAMPERS, ACCESS SOURCE. 17 3 PLENUM BOX INSTALLED OVER A LOUVER IN THE MER. DOORS, ETC. 245. 0.1-01 /' /� ' , f 1 s. EXISTING SUPPLY DUCT TO REMAIN (TYPICAL). 245.1`- 2 ` �`` / PROVIDE ALL COSTS ASSOCIATED WITH SERVICING THE UNITS THROUGHOUT THE PROJECT. AT THE 4. DEMOLISH MOTORIZED DAMPER FOR SPILL AIR ( ) � ' �,:' S7ACK1 I+''f ` END OF THE PROJECT AND AFTER VERIZON HAS ACCEPTED THE NEW EQUIPMENT, THE MC SHALL AT EXTERIOR WALL. 17. EXISTING RETURN AIR GRILLE TO REMAIN AND 20 PATCH ALL OPENINGS, REMOVE PIPING, ETC. AND REMOVE THE COOLERS FROM THE PREMISES. BE RE-USED. REMOVE RETURN GRILLE DURING FLEXIBLE DUCT AND CONDENSER HOSE TO BE RETURNED TO JAMES DILLON AT END OF PROJECT. 5. EXISTING LOUVERS TO REMAIN AND BE CONSTRUCTION TO ALLOW FOR SPOT COOLER %`'' f ` i / M I RE-PAINTED. PROTECT DURING DEMOLITION HOSES. FIRE DAMPER TO BE REPLACED. x ` is I�i���' r' .% ` ' 4 ��i AND CONSTRUCTION. CLEAN GRILLE PRIOR TO RE-INSTALLATION. o r' / 6. DEMOLISH HOT WATER UNIT HEATER AND 18. EXISTING TRANSFER AIR GRILLES TO REMAIN. 2 / r ' ``''r'f' 10 I A/C REPLACEMENT KEY NOTES OX ASSOCIATED HOT WATER SUPPLY AND RETURN PROTECT DURING DEMOLITION AND + I ,` �/ ,./ 5 PIPING. CONSTRUCTION. FOR CARRIER SWRM 20 1. PRIOR TO DEMOLITION, INSTALL NEW EXHAUST AIR FAN, 339-01-01 WITH MOTORIZED DAMPER 7. DEMOLISH HOT WATER SUPPLY AND RETURN 19. EXISTING HI/LO TEMPERATURE SENSORS TO FD AND LOUVER, L-1. MOUNT AND SUPPORT FAN TO GC PROVIDED EXTERIOR WALL OPENING. FAN PIPING TO POINT OF DISCONNECTION. CAP REMAIN. TO IRUN CONTINUOUSLY. BOTH PIPES. / 2. TRANSPORT AND INSTALL FOUR 4 5-TON SPOT COOLERS IN LOCATIONS SHOWN. 8. DEMOLISH CONTROL PANEL, 649-01-01. 20. SNAKE OUT EXISTING FLOOR DRAINS. , , / / 31755 MAIN RD. 21. EXISTING BUILDING ALARM TERMINAL STRIP I _...--_---_ _ _ __�.. _ BG 3 _ - 1 C CHOGUE, NY 3. TEMPORARILY REMOVE RETURN AIR GRILLE TO ALLOW INSTALLATION OF CONDENSER AIR FLEX 9. DEMOLISH BREAK GLASS STATION AND CABINET TO REMAIN. j,; _ 4 GROUND FLOOR HOSE. PROTECT RETURN AIR GRILLE DURING DEMOLITION AND CONSTRUCTION. ASSOCIATED CONDUIT AND WIRING. I 3 9 22, EXISTING ABANDONED-IN-PLACE BOILER TO = � TITLE: 4. FURNISH AND INSTALL INSULATED CONDENSER AIR FLEX HOSE. HANG FLEX HOSE FROM GRAY 10. DEMOLISH CONDENSATE PIPE FROM BOTH REMAIN. BAR TO EXTERIOR OPENING AS SHOWN. UNITS TO FLOOR DRAIN. GROUND FLOOR 5. FURNISH AND INSTALL TEMPORARY PLENUM BOX TO ACCOMMODATE FOUR (4) HOSES. 11. DEMOLISH SUPPLY AIR DUCT AND ASSOCIATED 23. EXISTING ELECTRIC WATER HEATER TO REMAIN. 0' 2' 4' 8' TEMPORARY SPOT COOLING INSULATION AND FLEX CONINECTION UP TO & DEMOLITION PLANS 6. FURNISH AND INSTALL CONDENSATE TUBING FOR EACH SPOT COOLER. CONDENSATE TUBING POINT OF DISCONNECTION. 1/4's = 1'-0" FROM EACH SPOT COOLER TO BE ROUTED AND DISCHARGED AT FLOOR DRAIN IN MER. DO NOT DATE: 8/16/17 CREATE A TRIPPING HAZARD. AVOID ROUTING OVER TELECOMMUNICATION EQUIPMENT TO THE BEST EXTENT POSSIBLE. PROJECT NO: 17-2165 7. INSTALL ONE (1) OSCILLATING FAN TO SERVE OFFICE DURING DEMOLITION AND CONSTRUCTION. DRAWN BY: EAB CHECKED BY: KJH / PEJ SCALE: AS NOTED DRAWING NO: 1 GROUND FLOOR TEMPORARY SPOT COOLING PLAN 2 GROUND FLOOR DEMOLITION PLAN, 0' 4' 8' 16' 01"9 000- SHEET NO: 2 OF 9 SCALA V854-7 SCALE: V8'-?-0' 1 /81' = 19-011 CONSTRUCTION KEY NOTES O (-500) _ _ .F ~.. . � `"` � ~ �-_....__ _ ___.~~ 1. REFER TO TEMPORARY SPOT COOLING PLAN FOR MORE INFORMATION. M '~ �::::;� L _;; __ ,~ 2. INSTALL A/C UNITS, 313-01-01 AND 313-01-02. INSTALL BOTH UNITS ON I INDEPENDENT 6" FLOOR STANDS (PROVIDED BY MFG.) WITH NEOPRENE WAFFLE PADS. PROVIDE WITH CONTINUOUS SEAMLESS STAINLESS STEEL DRIP PAN UNDERNEATH EACH 339-01-0 1 2412 I A/C UNIT. PAN TO EXTEND 6" BEYOND FOOTPRINT OF THE UNIT AND HAVE 4" HIGH Fi E li .,.moo......_:;""....q.( �......_._.~ SIDES. ROUNDOVER ALL SHARP EDGES. NO CAULKED SEAMS. PROVIDE PANT LEGS AND f _ 26 (250) FLEXIBLE CONNECTIONS ON SUPPLY AIR DISCHARGE OF A/C UNITS. PROVIDE MINIMUM ~"" "'~ r �... 20x20 HINGED ACCESS DOOR IN VERTICAL SECTION FOR ACCESS TO MOTORIZED -- !• ` ' DAMPERS. 250 :..._ ....... ;,, \ ) T. I i COMP DEHY. RM vD 21 DC POWER ROOM i x / 400 3 INSULATED DRAIN CONDENSATE FROM COPPER ITS AND DRIP PANS USING SEPARATE 4 ( ) PIPES TO CLOSEST FLOOR DRAIN IN MER'. SR-1 _ ROUTE CONDENSATE FROM UNITS TIGHT TO DRIP PAN. AVOID TRIPPING HAZARD. �„ -�---•~--� _•� _ 4. INSTALL TWO (2) LEAK DETECTORS PER A/C UNIT. LEAK DETECTORS BASED ON LIEBERT, Jacobsen & Horan MODEL LT410. INSTALL ONE IN EACH DRIP PAN AND ONE ON FLOOR ADJACENT TO EACH A/C UNIT. SECURE LEAK DETECTORS WITH EPDXY. REFER TO SEQUENCE OF OPERATIONS. Engineering, P.C. TG L990 South 2nd Street kM 5. LEAK DETECTOR POWER SUPPLY BY EC.22 Ronkonkoma, NY 11779 Mw morm" N W o - -- -� ---------•----L 6. FURNISH AND INSTALL NEW BAS ALARM PANEL, 650-01-01. MOUNT PANEL 5'-0" AFF. 0: (631) 580-6100 e00 __.__._._._ •-� ... ___ ._ .....!'T � -, . �' -:.__....._......... I F: (631) 58 - �, - _~ --•• _�� I - __ __ _ - _ ... ;.___. _ _......_- ...._ ...- _ 7. COMMON ALARMS 1FROM A/C UNIT AND LEAK ALARMS FROM LEAK DETECTORS TO BE 0 6101 www. 'he c com ~ _.....~ ~ ~- _;r.~�"```~�~ - -' WIRED TO 650-01-01. ROUTE NEW CONTROL WIRING IN 1" EMT CONDUIT FROM 1 P -... �... __.. _._.� .-� 650-01-01 TO THE BATSC BOX IN THE SWITCHROOM. ..� �. .»� .•, . .�� .... .. �. !77��.� ...... ..fie ..._.. ...._.. _..... ........ ....... .._... ........,...... ...._.. ..._... _...a;..,._.. _._... .._._ .._._. ... ........ ...._. ..._. ........ �.._ ......- __.... ... ...... ._._.. .. .__.- ---.... ........ ........ ........ ....... ....... ._.... ....... ........ _.._.. ........ ....... ........ ....... ....... ._.... ._..... ._ _ .. � � `� �� �� ' � � � �� � EMG. ENGINE RM. 8 f «� � ..... .,,� M�. ,� ...... .�, .�. �.�, ., .. WARNING: ._ r \\ „ ( ) O C IT IS A VIOLATION OF NEW YORK ' TP 2 INSULATED WITHIN BLDG. GLYCOL SUPPLY AND RETURN PIPES FOR A/C UNITS, F � lei 36x14 27 -- - 313-01-01 AND 313-01-02. ROUTE PIPE TIGHT TO CEILING AND UP THROUGH THE '< IH J. STATE EDUCATION LAW FOR ANY c 0 F:O or �� �� '? Fo � m F. M ter. -1 " � wn `M 00 �` � N O R LESS ACTING UNDER PERSON, UN �' a EXISTIN PIT P KET TO PUMP PACKAGE AND DRYCOOLER ON THE ROOF. LABEL �P 0,p � THE DIRECTION OF A LICENSED G CH OC 21 00 I co (v� � .y � PROFESSIONAL ENGINEER, TO ( ) GLYCOL PIPES EVERY 8 FEET. PROVIDE AIR VENTS AT ALL HIGH POINTS AND DRAINS AT ALTER AN ITEM ON THIS DRAWING * Z IN ANY WAY. IF AN ITEM IS BASE OF RISERS (TYP-2 PIPES PER A/C UNIT) INSIDE DRAIN PAN. FILL THE ENTIRE �a �'': ALTERED, THE ALTERING ENGINEER 101 r SYSTEM WITH 40% PRE-MIXED PROPYLENE GLYCOL. PIPES TO BE BRAZED THROUGHOUT. = �. c SHALL AFFIX TO THE ITEM .. �...~ _•__we I SUSPEND PIPING WITH TRAPEZE HANGERS, PIPE STANDS & LATERAL BRACING A cn �, HIS/HER SEAL AND THE NOTATION -- .... ........ .... ........ ........ . .. .... ........ ....... . S ... ,_,. ,�... ..� ,,. :,�. .. : :,�. .,�. ....o. .. ..:, .-... .,� .... �� .�,.. .�.. ...• .M.... ..... ,�.. .... �,. mr.M .... �.. ...�._»,,,. ,�,, ..... .,... . ,, ..�,. "ALTERED BY FOLLOWED •. .�:: . �,.. .� ..�.::...� �,... - .�...• ......w ..� REQUIRED .b.,. ,� ,�,,, LLO ED 6Y ;!.. .... ........ ....... ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ .: HIS/HER SIGNATURE AND THE ( FoA 073573 � , DATE OF SUCH ALTERATION AND A 5ESS DIG. SW. E I 9 SPECIFIC DESCRIPTION OF THE I 9. LIEBERT TEMPERATURE SENSORS FOR CARRIER SWITCHROOM. WIRE TO RESPECTIVE A/C OFESS1ONP ALTERATION. UNIT. � - _ ' ! CONSULTANT: 10. INSTALL 120x60x24 INSULATED SUPPLY AIR PLENUM ABOVE THE A C UNITS. 12-1 TECHNOLOGY DRIVE _ / , SETAUKET, NY 11733 27 ` (A 11. INSTALL NEW RETURN AIR FAN, 340-01-01. SUPPORT FROM CEILING AND MOUNT 9'-0" P. 631.689.8450 I I j x AFF. F. 631.689.8459 - www.wfcaia.com _ _ ._._._.._...._.___..;...~._ ~ ..__..___....__.._._.____...... .._____.._ _.__.._._.___.. ...__._.;____... ~ _.._._........._...._..._..... ........ _ . 12. INSTALL RETURN GRILLES, RG 1, AND DUCT AND CONNECT TO RETURN AIR FAN \ �r _.._ ___...._.~ A i __ _"36x1 TP BATSC, \ \\\ L (TYP-4) INSULATE RETURN AIR DUCT IN PLENUM ABOVE THE CORRIDOR AND LUNCH ...� �.. :. LOUNGE I T E C T S : �. ..,� r _.. _._.. ._..__ ______--- _...... ....�......�__, �---____.. ._.__...�..-... ....-......_..._.._. .. � .._� AND IN MER. ._..,... ..._.._._.: ..�...__ ......�............._..........._....__. _.._._ ..._.�......._._._�......-...r_...._........._... �._..._....-......._ 2100) .. _ .._.. _ .__._ _.... _.. ..._ _... .__ ...._ _. _ ._ _..... .._ _..... ...; 7 . •. » �•. .�. �... _ �,,� .•• -• ,� • ,�• ,� �,,, ., m; . ..� :....... __.... _, ........ .. M -_ .. ALL OUTSIDE AIR FAN, 341-01-01. INSTALL FILTER BOX, F-1 UPSTREAM OF ..__. __.... ..__ _...._ .._._ __. _.._ ........ _...... ..._.. ....._ _.... ._..... _. _..._ _....._ __ __ _ _ __.. __... ._..... _._... .._._ . OUTSIDE AIR FAN. NO. DATE SUBMISSION �� •�� � € ~ HI LO _.__ i `� 14. INSTALL MOTORIZED ISOLATION DAMPER (ONE PER A/C UNIT AND ONE FOR OUTSIDE AIR 1 10/10/17 ISSUED FOR BID / ~ I EI ~ ---,,; -;;^m„~~ T^ ~- M,,;; FAN). ACTUATOR BASED ON BELIMO, MODEL AFBUP-S, 24 VOLT. WIRE INTO RESPECTIVE 2 11/02/17 ISSUED FOR FILING . ._... _.-_.... .. .._..._ ........~_ ......._ _..__.....__i. _.- _ t_-. i T T = __M _ I MOTOR CONTROL CIRCUIT. 313-01-0 13-01-02 1...._._ ..._. ......._ _ __.. _ - 15. INSTALL URN E, RG-2, IN DUCT UPSTREAM OF OUTSIDE AIR FAN FOR RET GRILL co "r......... "' "- =% PRE-CONDITIONING OF OUTSIDE AIR. t x r� 16. TAP NEW SUPPLY AIR PLENUM AND ROUTE NEW 52x24 SUPPLY AIR DUCT INTO CARRIER 0 x ' I SWITCHROOM TO POINT OF CONNECTION. INSULATE SUPPLY AIR DUCT WITHIN MER AND 0) 0) 330-01-01 I I BOILER ROOM ONLY. =••~ 16 .........._.... _..._...... ._............. 17. TAP BOTTOM OF EXISTING DUCT BRANCH AND TEE TWO (2) 26x8 DUCT TAPS INTO I _- 19 BOILER RM 29 EQUIPMENT AISLES AND TERMINATE WITH DRUM LOUVER, DL-1, AND VOLUME DAMPER AT ..� ~~ ~ ~~m `~~_w ~ "`~ -~ ~ ~~ ~ W ~ ~ � I I 9'-0" AFF. COORDINATE EXACT LOCATION IN AISLE WITH VERIZON WIRELESS EQUIPMENT I _ A x LAYOUT PRIOR TO INSTALLATION (TYPICAL). r- o F VD 17 (1000 -' 18. INSTALL NEW VOLUME DAMPER IN EXISTING SUPPLY AIR DUCT. !_ X VU 25 19 I KEY PLAN: ___ .. _........_. ............ ._ ._. .� 42x ! _-•;- 19. INSTALL NEW FIRE DAMPER IN NEW SUPPLY AND RETURN WALL OPENINGS. INSTALL 5ESS/TOLL STORERM w :.........,„ DOOR WHERE INDICATED OR REQUIRED FOR PROPER ACCESS (TYPICAL). � .� r v �. - r - Q E S t:: e. .� �: .� � c �� 44x1 LABEL _ . 6. <'' � FD ( 6 VD< DAMPERS. _ - I 20. INSTALL NEW FIRE DAMPER IN EXISTING RETURN GRILLE OPENING. LABEL DAMPER. 5ESS MTCE. CTR. ............. . E_. __ D ! (..�. _ ._._. __ __. ... 8D 5 650- 21 1 ®AD 28 I . INSTALL SUPPLY REGISTER, SR- , WITH VOLUME DAMPER ON EXISTING DUCT OPENING. V II . I j 25 cD �t 01-01 ! I� j� I _ �•• m SEAL DUCT AROUND REGISTER. T1 N i =s x _ _. FD -� _ 24 N 8 22. INSTALL TRANSFER GRILLE, TG-1, ON BOTH SIDES OF WALL WITH FIRE DAMPER. , (100) ............ ....... 7 6 `n 15 14 I• (150) € (150) - - --~ � 17 1000 (300) 23. INSTALL A PRE-MANUFACTURED SOLID BLANK-OFF PANEL OVER ENTIRE LOUVER } I _ ......__ _......_.. VD GLY ar av OPENING. BASIS OF DESIGN IS 'THERMOLITE' AS MANUFACTURED BY LAMINATORS INC.. .. E f ta 26 � DL-1 �� AND SHALL INCLUDE DOUBLE WALL 0.024" FACE AND 0.013" BACKER, ALUMINUM F� PANEL SURROUNDING 2" ISOCYANU ATE INSULATION \ I j�•.\j � � .�..,,� I i I 20 M $; _ (MIN. R-VALUE OF 5.6). PANEL t/ VD S U R 1 I € FINISH TO MATCH EXISTING LOUVER. FASTEN AND SEAL PANEL TO INTERIOR OF WALL (1 ppb: _ ?. ._.. _ .. • No 14 313-01-02 i OPENING f,. FD RG-2 ''` 26 I (-500 ! 24. INSTALL NEW QUADRANT HANDLE ON EXISTING SUPPLY DUCT FOR BALANCING PURPOSES. ABPA OF WORK ' " " 25. AVOID THREADED ROD INSERT LOCATIONS. IF DUCT PASSES UNDERNEATH, x THREADED THEN INSTALL 1 - ROD THRU DUCT SEE DETAIL . :..I (300) , I .I O ( ) r` . cfl 01-01 3 Tfi _._ _ _._T_ _.. x ; = 4 2 x I FD I 40 26. BALANCE AIRFLOWS TO VALUES INDICATED IN PARENTHESES FOR UNITS 313-01-01 AND 12 j 13313-01-02 (TYPICAL). SEE TESTING, ADJUSTING AND BALANCING SPECIFICATION. CARRIER EQPT. (1000) 3 i TOLL ADMIN T 27. TRAVERSE POINT FOR BALANCING. * _• ,. `RG-1 t -- s- - ~ - -- -- a14313-01-01 340- 28• LAMINATE AND MOUNT THE FOLLOWING ON CLEAN WALL SPACE: - - --; i _ I 01-01 23 28.1. CONTROL WIRING DIAGRAMS AND DRAWINGS 28.2. SEQUENCE OF OPERATIONS 26 1000 I s € 28.3. VALVE CHART _�....... ......... �... ;;... -:� � .._m- .-.. - ... ) , 1 (300) 1 1 FD 28.4. PIPING DIAGRAM I = 29. TAP EXISTING DOMESTIC COLD WATER PIPE AND ROUTE NEW 3/4" INSULATED AND BG LABELED COPPER TYPE 'L' PIPE WITH ISOLATION VALVE UP TO ROOF IN EXISTING PITCH A/C REPLACEMENT -` I......., .......!...... ,r,. X I POCKET WITH GLYCOL PIPING. PROVIDE DRAIN AT BASE OF RISER. FOR CARRIER - SWRM (1010) (150) 19 r~ _, FT CO STOR / LOCK E ,� & LOUNGE 31755 A RD ^ PWr LOW, N I FS. ' CUTCHOGUE, NY ..... ............ _ GROUND FLOOR .... ._ i _.. ___.. (200) ..- ._.~. TITLE: 12 c -m_m ..- : _ ___ _ GROUND FLOOR CONSTRUCTION PLAN ,. _._...._. ... ;I ..m .... ........ ... FD 19 All �...; ®16x12 �....�� ...�..... ....... � ,i _ - - � - _ ...._.__..W._,._,. .. DATE: 8/16/17 RG 12 RG 1 12 �..,... 12 RG 1 ._.. _ r g • � 2165 _ DRAWN BY: EAB ....� _ MDF ............ (...... : UNISEX TLT. CHECKED BY: KJH / PEJ (500) (200) _ - _ .... .. - __ SCALE: AS NOTED ,i DRAWING NO: 1 PARTIAL GROUND FLOOR CONSTRUCTION PLAN 2' 4' $' 6%MP00%===� M M 10 0 0 0- SHEET NO: 3 OF 9 f Jacobsen & Horan I Engineering, P. C. I 990 South 2nd Street 77 i I Ronkonkoma, NY 11779 f Lo)) 0: (631) 580-6100 f .�-...� ;I I _.._..�....._. .... .......�_......._'3__......`..._......,..�......�t�aT__ � F. (631) 580-6101 www.jhepc.com f ..... .. „„ „„r... _................._ ._.......,....._.... pp'� I _._.._. . g f ` I V �/ STATE EDUCATION LAW FOR ANY �� f � <"� � f IT I��VIOLATION OF NEW YORK '/ ` PERSON, UNLESS ACTING UNDER I _••• +-�+' •�� �� �-wl ••. � � �` � H � PROFESSIONAL ENGINEER, TO co �� ALTER�O� THE DIRECTION OF A LICENSED �..�."'� � � ,f �.mm..� ;>':��..........,.W..__....w... ...—..._-......,v,.. ` f � vD WING �.I . j NANY WAY EF AN ITEMIS TE ED, THALTERING ENGINEER SHALL AFFIX TO THE ITEM - `�:•'<<',%/` �' uYM""�„"`^`-� f � € � + � HIS/HER SEAL AND THE NOTATION .... E ...__ ��: f � � 41 "ALTERED BY" FOLLOWED BY f ._.__ �Y ._. .._`... �_._.. ......m... ._.... ... �.-.. 1 � _ _._ ._.. r f f TE - 3 i HIS/HER SIG ........�..............-�.... ............�..._.....r..., t, .........,; `:,. ...._.r........ ...._...$... •-,...-� � / R NATURE AND THE a.. .. . _. ..._._.1_ '..� Fu a __.. _ __ ms tiQ/' �� � DATE I OF SUCHRIPTION TION AND A ' - "-"' "' " -- ' 35 C IPTION OF THE - _ — a.. ..... ._ __... 3 — , SPEC FIC DES I -'-'.�-',.� � f ..........._.. .�.. ._.... ..;�...._...._........�......_....w... _.. ..._...._... ALTERATION. CONSULTANT: I i.'`. 12-1 TECHNOLOGY DRIVE, f SETAUKET, NY 11733 :'--.L .__._, P. 631.689.8450 3 _ . _....._. F 631 9 59 ' '// T// f f I I ./ ` ��,.� � "' E .. I � I �.......... � \•\ ; -.. . www wfcaia com 68 ...._........,._....,......._...._....h!�eF... �,tee_. .. Se!Lr.. ._� f I T E C T S f E: .. : /� .�.�.. .._ f DATE SUBMISSION fillii 1 10/10/17 ISSUED F . v OR BID 2 11/02/17 ISSUED FOR FILING w........... �............ .....,,ate,... .... ,.. 4 IL w' KEY PLAN: I i ,E. , 1 I _f 5 CONSTRUCTION KEY NOTES O __..._. __.___._....._ ._ ._ _ .._ .. _. __. _ ._-... DEMOLITION KEY NOTES G) ARFA OF WORK 1. FURNISH AND INSTALL DRYCOOLERS, PUMP PACKAGES AND COMPRESSION TANKS i s '� 6 1. DEMOLISH AIR-COOLED CONDENSERS AND ASSOCIATED PIPING IN ITS ENTIRETY. ON EXISTING STEEL DUNNAGE. SECURE DRYCOOLERS TO DUNNAGE WITH RECLAIM R-22 REFRIGERANT PRIOR TO CUTTING PIPES. TURN OVER STAINLESS STEEL BOLTS NUTS AND WASHERS. GL REFRIGERANT TANKS TO VERIZON PROPERTY MANAGER, JAMES DILLON. ' f 1 UGLY LitYY- GLYY GL.Y 2. FURNISH AND INSTALL NEOPRENE WAFFLE TYPE VIBRATION ISOLATION PADS c 2. DEMOLISH ROOF PIPE SUPPORTS. ' UNDER EACH DRYCOOLER LEG AND PUMP PACKAGE CORNER. '� 1 2 3 ridF 1 2 �!_- 3. EXISTING STEEL DUNNAGE TO BE RE-USED FOR NEW DRYCOOLERS. REFER TO 3. INSTALL WIRE MESH SCREEN UNDER PUMP PACKAGE. dd ,r CONSTRUCTION PLAN. !{ 4. GLYCOL PIPING ROUTED FROM THE MER TO ROOF THROUGH EXISTING PITCH - - - - 7 4. EXISTING EXHAUST FANS TO REMAIN. POCKET. PIPING TO BE INSULATED WITHIN BUILDING AND UNINSULATED ON ROOF. 5. FURNISH AND INSTALL IPIPE SUPPORTS EVERY 6'-0" AND EVERY CHANGE IN DIRECTION. RE-USE EXISTING PIPE SUPPORTS WHERE POSSIBLE. i 6 I I aY aY a. 6. SUPPORT PIPES FROM DUNNAGE WHERE POSSIBLE. f.,.'I 210-1R-02 'Li;.: ar aY A/C REPLACEMENT titY GLY Gy G_y aY FOR CARRIER SWRM 7. NEW 3/4" FROST-FREE HOSE BIBB WITH DRAIN. ••1iY••• a.Y� -aY f _ .. rax-� raY-, ,• ' 1 2 4 ZD d31755 MAIN RD. 1 Ell CUTCHOGUE, NY 210-1 R-01 2 GROUND FLOOR I € 3 j !II ? _ TITLE: ROOF - — I. - DEMOLITION & CONSTRUCTION PLANS f DATE: 8/16/17 0' 2' 4' 8' PROJECT NO: 17-2165 DRAWN BY: EAB 1/40' = 1'-O" CHECKED BY: KJH / PEJ SCALE: AS NOTED DRAWING NO: am 1 ROOF DEMOLITION PLAN 2 ROOF CONSTRUCTION PLAN of4' 8' 16' 46-114- U's . 00 v8'�1'-0� SHEET NO: 4 OF 9 SCALE VIM SCAM 1/s = 1 —o SLA NEW PIPING & ELECTRICAL CONDUIT " - ':�,•',..••• • ' ' AS REQUIRED (TYP) s a PIPE CLAMP ® PIPE CLAMP ASSEMBLY BEAM BEAM CLAMP �� �D ELECTRICAL © REFRIGERANT/GLYCOL CONDUIT PIPES INCLUDE RUBBER ' OR EQ, INSERTS INSIDE CLAMP. s SUPPLEMENTARY O O O STEEL CHANNEL (HG). STRUCTURAL MEMBER PIPING SUPPORTS SET 6'-0" OC (MAX) OR WITHIN 18" OF A s 90' DIRECTION 2 4. CHANGE (UON). 3 NEW Jacobsen & Horan o-AE 3 4 SHEETMETAL CONSTRUCTION BOOT TAP. PROVIDE SCREWS ONLY VOLUME DAMPER UP HIGH 00 NON-PENETRATING CLOSE TO TAP IN DUCT. - VD PIPE SUPPORT Engineering, P.C. IK , 74 DEVICE. L s 990 South 2nd Street Ronkonkoma, NY 11779 4 THE MINIMUM REINFORCING ANGLE SIZE FOR DUCTWORK O: (631) 580-6100 NOTES: WITH A DIMENSION OF ITS LONGEST SIDE AND MAXIMUM LONGITUDINAL SPACING SHALL: --- --- -- - F: (631 580-610 1. H.I.T. OR CADDY (BEAM CLIP FOR APPROPRIATE BEAM . ) 1 °° www.jhepc.com THICKNESS. 43 TO 48 - 1 1/2 x1 1/2"x1/8" @ 60 t .. d E bd �^ •, �� EXISTING ROOFING DRUM LOUVER ^ . ° 49 TO 60 - 1 1/2 xl 1/2"x1/8" ® 48 •. ° . ° ••. � .� ••' ° .. • ,. •" � SYSTEM. HANGER STRAPS „ „ W/ OBVD ® rte_ 2. PHILLIPS JS14C (BSA APPROVAL NO.39058 SM) OR 61 TO 96 - 1 1/2 x1 1/2"x3/16"@ 24 IT I� A VIOLATION OF NEW YORK EQUAL, OR FORCED ENTRY FASTENERS. 97 TO 120 - 2" x 2" x 1/4" ® 24" 9 -0 AFF (+/-) 16" �F N E y STATE EDUCATION LAW FOR ANY (UNLESS NOTED 3. BAND IRON HANGER PER CODE OR SMACNA. ) (10" WIDE) '< F,�H J. NO O� THESDR'ECTIONSOF A ACTINGUNDER OTHERWISE ���� '�-9 '� PROFESSIONAL ENGINEER, ?0 2ALTER AN ITEM ON THIS DRAWING NOTES IN ANY WAY. IF AN ITEM IS HANGER SIZE •� ,; ���� � ALTERED, THE ALTERING ENGINEER W SHALL AFFIX TO THE ITEM 4. TURN UNDER WHEN DUCT IS OVER 47 WIDE. r- to HIS/HER SEAL AND THE NOTATION 1. PIPE HANGER BASED ON PORTABLE PIPE HANGERS. INC. FOR PIPES 2 Y2" OR C) y ALTERED BY" FOLLOWED BY RECTANGULAR DUCT �� �� HIS/HER SIGNATURE AND THE 5. PHILLIPS J38C OR EQUAL SMALLER, USE MODEL PP10 W/ STRUT. FOR PIPES 3 & LARGER, USE MODEL s�, 07353 �,�, DATE OF SUCH ALTERATION AND A PSE-2-2. pRO `O�P '• ALTERATION. DESCRIPTION OF THE 6. THREADED ROD COUPLING. DUCT SIZE HANGER HORIZONTAL SUPPORT .ANGLE 2. ALL PIPING & CONDUIT CLAMPS AND ASSOCIATED NUTS & BOLTS SHALL BE SST. 7. THREADED ROD (,SIZE AS REQUIRED 3/8" MIN). CONSULTANT: UP TO 2 SQFT 1 x 1/16" NONE 3. PIPE SUPPORT FURNISHED BY MC INSTALLATION & ROOF MODIFICATION BY GC. .. 12-1 TECHNOLOGY DRIVE, 8. SCISSOR CLAMP ON REINFORCED ROD. BAND IRON SETAUKET, NY 11733 9. G.A.T. CHANNEL CLAMP SLAB FASTENER. OVER 2 SQFT 1" x 1/8" NONE 4. BASE BID TO INCLUDE TWO (2) SUPPORTS. ALSO INCLUDE A UNIT PRICE FOR ., P. 631.689.8450 „ BAND IRON EACH TYPE OF SUPPORT (IF REQUIRED). F. 10. STEEL ROD (3/8 MIN.) OVER 4' WIDE 1 x 1/8 NONE w ww6aia.co 9 BAND IRON �, www.wfcaia.com 11. TO BE REPLACED WITH METAL LATH & FIREPROOF 2 DRUM LOUVER DETAIL 3 ROOF PIPE SUPPORT DETAIL PLASTER TO ACHIEVE ORIGINAL FIRE RATING. NOTE: OVER 8 SQFT 1" x 1/8" SEE NOTE SELF TAPPING CADIUM PLATED HEX BAND IRON SCALE: N.T.S. SCALE: U.S. I T E C T S HEAD SHEET METAL SCREW STRAPS TO BE TIGHT AGAINST DUCT OVER 10 SQFT BAND IRON SEE NOTE NO. DATE SUBMISSION 1 DUCT HANGING DETAIL 1 10/10/17 ISSUED FOR BID SCALE: KT,S. LOCK NUT W/WASHER 2 11/02/17 ISSUED FOR FILING AGAINST RUBBER RUBBER WASHER ROD (SIZE PER CEILING INSERT - GALVANIZED 1-1/2" UNISTRUT CHANNEL DUCT TYP. 5/8") BUSHING ON CONDUIT END UNISTRUT PIPE CLAMP ASSEMBLY OR EQ., ® REFRIGERANT/GLYCOL PIPES W/ 1" MIN ON TOP & THREADED RODS SECURED TO RUBBER GASKET AT PIPING CONTACT TOP OF MAIN DUCT. BOTTOM. I I RUBBER WASHER CEILING STRUCTURE AS REQUIRED. NEW PIPING & ELECTRICAL 1/4 BRANCH DUCT LOCK NUT W/WASHER AGAINST RUBBER I ` CONDUIT, AS REQUIRED (TYP.)-­�, 45 WIDTH (MIN 4"). UNISTRUT P1112 PIPE CLAMP, O PSR LOCK NUT W/WASHER AGAINST RUBBER �OR EQUAL, ® 3/4" CONDUITS EQUAL TO REQD. 1" RIGID GALV. I I RUBBER WASHER BRANCH DUCT ELECTRICAL KEY PLAN: O DIMENSIONS. CONDUIT 00 RUN PIPES TOP - VOLUME DAMPER RUBBER WASHER = �! OR BOTTOM (TYP). LOCK NUT W/WASHER AGAINST RUBBER 00 = UNISTRUT P/1000T 1000T 15/ X" SEAL ALL BUSHING ON CONDUIT END O AROUND. 1%" WITH GREEN FINISH O NOTE: 1. ASSEMBLY TO BE PROVIDED WHENEVER EXISTING THREADED ROD CONFLICTS OCCUR AND WHEN DUCTWORK BLOCKS EXISTING O �) IQIQQEXPANSION BOLTS (TYP.) CEILING INSERT/BEAM CLAMP ACCESS. 2. A MINIMUM OF 8" OF EXPOSED THREAD SHALL PROTRUDE BELOW ( `I WALL THE BOTTOM OF THE DUCT. 3. MC SHALL ASSUME A TOTAL OF FOUR 4 CEILING INSERT AS REQ'D. TO SUIT CONFLICTS EXIST UNDER THE BASE BID. ' NO. OF PIPES & CONDUITS 4. MC SHALL MAKE ALL ATTEMPTS TO AVOID THREADED ROD INSERTS ! . •:,:--_ . .::_. . -;. Y;- ,,., WITH ITS NEW DUCTWORK. NOTES: AitPA OF WORK LENGTH OF UNISTRUT TO SUIT REQUIRED N0. OF PIPES & CONDUITS. 5 DUCT BRANCH DETAIL. 6 THREADED ROD THRU DUCT DETAIL, SCALE N.T.S. SCALE U.S. MAXIMUM SPACING OF UNISTRAT UNISTRUT 6'-0" O.C. ALL PIPING AND CONDUIT CLAMPS AND ASSOCIATED NUTS AND BOLTS SHALL BE STAINLESS STEEL. GENERAL NOTES: ANGLE IRON FRAME. ALL FOUR SIDES ANGLE IRON TABLE FOR WALL INSTALLATIONS, ALL ELECTRICAL CONDUITS TO BE ABOVE ALL PIPING. FASTENED TO DUCT SLEEVE. SEE TABLE. WALL OPENING ANGLE SIZE 1. DAMPER BASED ON RUSKIN, MODEL DIBD2, STYLE B. LINTEL. UP TO 54" 1-1/2"0-1/2"0/8" V, fill 4 PIPE SUPPORT DETAIL 55" TO 84" 3"x2"0/16" 2• FIRE DAMPER TO BE UL LABELED, FIRE (RATED WALL PARTITION. NFPA 90A COMPLIANT & 1-1/2 HR SCAM U.S. 85" TO 120" 3"x2N3/16" RATED FOR WALL/FLOOR PROVIDE CLEARANCE FOR CONSTRUCTION.� , :�. ;, NOTE: RETAINING ANGLES MUST LAP DAMPER EXPANSION ON BOTH �j' STRUCTURAL OPENING 1" MIN. AND 3. NFPA APPROVED INSTALLATION GENERAL NOTES: SIDES & TOP AS REQUIRED. COVER CORNERS OF OPENINGS. DETAILS TO BE PART OF A/C REPLACEMENT LINTEL. 1. DAMPER BASED ON RUSKIN, MODEL ' SUBMISSION OF FIRE DAMPER FOR DIBD2, STYLE B, BSA #297-71-SA. MANUFACTURER FURNISHED SLEEVE. APPROVAL, WHICH SHALL MEET FOR CARRIER SWRM ANGLE IRON TABLE 3 NFPA STANDARD 90A. 2. FIRE DAMPER TO BE UL LABELED, WALL OPENING ANGLE SIZE SEAL ALL S-JOINTS AT MI DUCT. FIRE RATED WALL NFPA 90A & BSA COMPLIANT & f`f. , UP TO 54" 1-1/2"x1-1/2"x1/8" BREAKAWAY CONNECTIONS. ��• -:% 3" 4. DETAILS SHOWN ARE FOR FIRE PARTITION. ;; 1-1/2 HR RATED FOR WALL/FLOOR MIN. DAMPERS IN HORIZONTAL DUCTWORK. FOR FIRE DAMPERS IN 31755 MAN RD. f i CONSTRUCTION. 55" TO 84" 3"x2"x3/16" PROVIDE CLEARANCE FOR i"'' VERTICAL DUCTWORK THE DETAIL IS CUTCHOGUE, NY DAMPER EXPANSION ON / 85" TO 120" 3"x2"x3/16" FIRE (DAMPER FRAME BOTH SIDES & TOP AS 3. NFPA APPROVED INSTALLATION FACTORY MOUNTED IN 2 SIMILAR NG LOADED. DAMPERS SHALL BE GROUND FLOOR REQUIRED. ;. f DETAILS TO BE PART OF SUBMISSION OF FIRE DAMPER FOR NOTE: RETAINING ANGLES MUST LAP SLEEVE. APPROVAL, WHICH SHALL MEET STRUCTURAL OPENING 1" MIN. AND 5. ACCESS DOOR IS SHOWN IN SIDE TITLE: f % OF DUCT; IF FUSIBLE LINK IS MORE MANUFACTURER % ,• . NFPA STANDARD 90A. COVER CORNERS OF OPENINGS. ACCESSIBLE FROM BOTTOM OF FURNISHED FUSIBLE LINK RATED FOR 50'F SLEEVE. i i 4. DETAILS SHOWN ARE FOR FIRE ABOVE MAX. TEMPERATURE OF S DUCT RELOCATE ACCESS DOOR. DETAILS IDEWALL GRILLE FLUSH DAMPERS IN VERTICAL WALL. FOR SYSTEM. SIDEWALL GRILLE FLUSH WITH WALL. FIRE DAMPERS IN FLOOR OR / 6. UL APPROVED BREAKAWAY SLIP WITH WALL CEILING, THE DETAIL IS SIMILAR ff / r JOINT CONNECTION SHALL BE USED. FIRE DAMPER FRAME I I EXCEPT DAMPERS SHALL BE SPRING BREAKAWAY CONNECTION (TYP). !% DATE: 8/16/17 FUSIBLE LINK RATED LOADED. 7. FIRE DAMPER FOR DUCT HEIGHT FACTORY MOUNTED IN I I FOR 50'F ABOVE MAX. LARGER THAN 24 IN. CAN BE IN PROJECT NO: 17-2165 SLEEVE. TEMPERATURE OF 5. FIRE DAMPER FOR WALL OPENING FASTEN FIRE DAMPER FRAME TO AIR STREAM. DRAWN BY: EAB V1114-,4 SYSTEM. LARGER THAN 24 IN. CAN BE INSLEEVE. ACCESS DOOR FASTEN FIRE DAMPER FRAME 10 AIR STREAM. (NOTE 5). B. THE DETAIL IS FOR GUIDE ONLY. CHECKED BY: KJH / PEJ SLEEVE. 'i' �'' INSTALL LABEL ON WALL INDICATING INSTALL FIRE DAMPER IN FIRE DAMPER. SCALE: NONE ' 6. THE DETAIL IS FOR GUIDE ONLY. ACCORDANCE WITH MANUFACTURER'S INSTALL FIRE DAMPER IN RECOMMENDATION. DRAWING NO: ACCORDANCE WITH MANUFACTURER'S190 � 000 FASTEN TO SLEEVE (TYP). RECOMMENDATION. 7 SIDEWALL TRANSFER GRILLE FIRE DAMPER DETAIL, 8 FIRE DAMPER FOR FIRE-RATED WALLS DETAIL, SHEET NO: 5 OF 9 SCALE N.tS. SCALE KT.S. COMPRESSION TANK (MINIMUM 24" 1" PRESSURE RELIEF (SET ® 50 PSI) & 1" COPPER ABOVE HIGHEST POINT OF SYSTEM). (TYPE L) DRAIN LINE (PIPE TO 12" ABOVE ROOF). SIGHT GLASS W/SHUT-OFF Sc AUTO-CHECK VALVES. EXISTING PITCH POCKET THROUGH ROOF, USE SAME PITCH POCKET FOR ALL PIPES & CONTROL CONDUITS (COORDINATE W/ ARCH DWGS). LOW LEVEL ALARM (WIRE TO A/C UNIT). 20 TIE-WRAP SENSING TUBES TO GLYCOL SUPPLY AND 15 GALRETURN PIPES. AVOID DISSIMILAR METAL CONTACT. GALLON ASME q COMPRESSION TANK 25 21 Z 24 D dP AIR CHARGER & TANK DRAIN 22 y Jacobsen & Horan W/HOSE BIBB & BRASS CAP. \ PUMP PACKAGE BLEEDER VALVE (TYP) STANDARD DRYCOOLER P T O O p_ 23 10 12 PS 16 Engineering, P.C. 990 South 2nd Street LEGS. -' Ronkonkoma, NY 11779 DRYCOOLER I I D I D D I I D F : (631) 580-6100 STEEL DUNNAGE. P T 11 13 P 15 17 SEQUENCE OF OPERATIONSOF: (631) 580-6101 O O O www.jhepc.com O6 5O D D 1. A/C C UNIT. 313-01-01 & 313-01-02 5. LEAK DETECTION 9. ALARMS 1.1. A/C UNIT SHALL BE MANUALLY STARTED. 5.1. THE A/C UNIT SHALL CONTINUE TO RUN IF 9.1. CLLI CODE FOR THIS BUILDING IS CTCHNYCU. F NEVA "� WARNING: THE PAN DETECTOR IS IN ALARM. THE UNIT ! O Y IT IS A VIOLATION OF NEW YORK ROOF 1.2. MANUFACTURER TIPROVIDED TEMPERATURE TEMPERATURE VIA SHALL SHUT DOWN ON ALARM FROM THE 9.2• CONTACT DAN MURPHY (VZ.) FOR PROPER ,`�Ci �(N J. /yo STATE EDUCATION LAW FOP ANY A/C UNIT AND ALARM DESIGNATION IN �- PERSON, UNLESS ACTING UNDER WIRE MESH SCREEN. SENSOR INSTALLED IN THE SPACE. PROGRAM FLOOR DETECTOR. h -9 THE DIRECTION OF A LICENSED GLYCOL RETURN (2") VERIZON NETWORK. ALARMS TO REFERENCE co W 2 PROFESSIONAL ENGINEER, TO SET POINT TO BE 78-F (ADJUSTABLE). 5.2. EACH LEAK DETECTOR SHALL BE WIRED TO CLLI CODE. * ALTER AN ITEM ON THIS DRAWING ITS RESPECTIVE A/C UNIT (FOR LOCAL CC IN ANY WAY. IF AN ITEM IS 1.3. ACRITICAL COMMON ALARM FROM THE A/C LU ALTERED, THE ALTERING ENGINEER / 9.3. GPNOC SHALL RECEIVE: c' w SHALL AFFIX TO THE ITEM UNIT SHALL SEND AN ALARM SIGNAL TO ALARMS), AS WELL AS THE NEW BAS PANEL _ 9.3.1. LEAK DETECTION �� HIS/HER SEAL AND THE NOTATION GLYCOL SUPPLY (2") GPNOC (VIA EITHER TERMINALS 75/76 OR VIA (FOR REMOTE ALARMING). 2 �, ALTERED BY" FOLLOWED BY 9.3.1.1.LEAK ALARM P1 STATUS). sF357'3 4. . HIS/HER SIGNATURE AND THE - NEOPRENE WAFFLE VIBRATION UNITY CARD). PROGRAM A/C UNIT iCOM ( ) Op N�� DATE OF SUCH ALTERATION AND A ISOLATION PADS UNDER EACH CORNER CONTROLLER IN ACCORDANCE WITH TABLE 9.3.1.2.PROGRAM 1 MINUTE DELAY PRIOR TO ROFESS\O . SPECIFIC DESCRIPTION OF THE NEOPRENE WAFFLE VIBRATION 6. DRYCOOLER. 210-1 R-01 & 210-IR-02 '� ... _ ALTERATION. ISOLATION PADS UNDER EACH O4 O OF PUMP PACKAGE. PADS WITH CORK BELOW. SENDING ALARM TO GPNOC. �"'�� DRYCOOLER LEG. PADS WITH CORK ARE NOT ACCEPTABLE. BOLT EACH 1.4. PROGRAM ICOM CONTROLLER SO THAT 6.1. INTERLOCK DRYCOOLER WITH A/C UNIT. 9,3,2, CRITICAL COMMON ALARMS FROM A/C UNIT CONSULTANT: CORNER (HAND TIGHT TO DUNNAGE. WARNINGS DOES NOT ACTIVATE COMMON 6.2• LEVEL OF GLYCOL IN COMPRESSION TANK TO 12-1 TECHNOLOGY DRIVE, ARE NOT ACCEPTABLE. BOLT LEGS T T ) (HAND TIGHT) TO DUNNAGE. ALARM TERMINAL. (SEARCH S232) BE MONITORED BY LOW LEVEL SWITCH. 9.3.2.1.HVAC FAIL ALARM (P1 STATUS). 9.3.3. HI/LO TEMPERATURE SETAUKET, NY 11733 1.5. THE RESPECTIVE ISOLATION DAMPER SHALL 6.3. UPON LOW LEVEL CONDITION, ALARM TO BE ` P. 631.689.8450 SENT TO A/C UNIT FOR LOCAL ALARMING 9.3.3.1.H1 TEMPERATURE ALARM P1 STATUS \ A C UNIT PROVE OPEN BEFORE A/C UNIT CAN ( )• k;'� � . ` F. 631.689.8459 / OPERATE. ONLY. 9.3.3.2.LO TEMPERATURE ALARM P2 STATUS). N www.wfcaia.com 6.4. PROVIDE TWO (2) #10AWG WIRES AND EIGHT 9.4. CONTROL VENDOR TO IDENTIFY ALL WIRING, 00 COOLING COIL PAN 2. OUTSIDE AIR FAN. 341-01-01 (8) #14AWG WIRES IN 1" EMT CONDUIT PATHS AND ALARMS ON THEIR SUBMITTALS. �;� • x. I T E C T S 2.1. FAN SHALL RUN CONTINUOUSLY. BETWEEN DRYCOOLER AND A/C UNIT. FOUR O2.2. THE RESPECTIVE ISOLATION DAMPER SHALL (4) #14AWG WIRES ARE TO BE COILED UP ON 10. CONTROLS SUBMITTAL 4" TALL SS DRIP PAN. SINGLE SHEET WITH WELDED PROVE OPEN BEFORE OUTSIDE AIR FAN CAN BOTH ENDS AND LABELED AS _.PARES. NO. DATE SUBMISSION CORNER SEAMS. CAULKED SEAMS AND/OR MATED FLAT OPERATE. 10.1. PROVIDE FULL SUBMITTAL FOR APPROVAL AT PANEL SECTIONS ARE NOT ACCEPTABLE. SEE O I 1" COPPER (TYPE L) GRAVITY DRIAAN LINE FROM THE INCEPTION OF PROJECT. 1 10/10/17 ISSUED FOR BID 7. PUMP PACKAGE. 474-1R-01/02 & 2 11/02/17 ISSUED FOR FILING CONSTRUCTION PLAN. ROUND-OVER TOP EDGE SO THAT A/C UNIT AND 3/4" COPPER (TYPE L) GRAVITY 3. RETURN AIR FAN. 340-01-01 474-1 R-03/04 10.2. SUBMIT AUTOCAD GENERATED POINT-TO-POINT NO SHARP EDGES EXIST. DRAIN LINE FROM DRIP PAN, BOTH TO FLOOR DRAIN WIRING DIAGRAM. INDICATE ALL WIRING AND GROUND FLOOR (INDIRECT, NO TRAP REQD), INSTALL CLEANOUTS AT 3.1. RETURN AIR FAN IS INTERLOCKED TO RUN 7.1. INTERLOCK PUMP PACKAGE WITH RESPECTIVE CONDUIT SIZES. z ALL BENDS. WITH EITHER A/C UNIT. A/C UNIT. 10.3. SUBMIT DETAILED SEQUENCE OF OPERATIONS. 6" TALL FLOOR STAND. 3.2. WHEN AN A/C UNIT IS COMMANDED TO RUN, 7.2• ONE (1) PUMP TO RUN AT A TIME. ONE (1) 10.4. SUBMIT MANUFACTURER CUT SHEETS FOR ALL LEGENDA SIGNAL IS SENT TO THE RETURN AIR FAN PUMP ON STANDBY. PROVIDED COMPONENTS. 4" TALL CONCRETE HOUSEKEEPING PAD. TO RUN. 7.3. PUMP FAILURE (AS SENSED BY DP SWITCH) 10.5. AT END OF PROJECT, PROVIDE COMPLETE 9 y WEKSLER A935A 3.3. RETURN AIR FAN OPERATION MAY ALSO BE WILL TRIGGER START-UP OF STANDBY PUMP. AS-BUILT SUBMITTAL FOR ENGINEERING THERMOMETER (40-140 -F RANGE) VIBRATION ISOLATION PADS OVERRIDDEN AT THE H-O-A SWITCH ON THE 7,4. LOCAL ALARM TO BE SENT TO A/C UNIT. REVIEW AND APPROVAL, PRIOR TO INSERTION PRESSURE GAUGE WEKSLER EA14 (NEOPRENE WAFFLE TYPE-SUPPLIED MOTOR STARTER (SUPPLIED BY MC AND INTO "CLOSE-OUT" BOOK. W/PETCOCK (0-100 PSI RANGE) W/ LIEBERT UNIT FLOORSTAND). INSTALLED BY EC). 8. BREAK GLASS STATION MIN 12" LONG TWIN CITY HOSE, INC., LIEBERT LT410 LEAK DETECTOR 8.1. ACTIVATION OF THE BREAK GLASS STATION ® FLEXIBLE CONNECTION TCHB-XXX-FFSC, CU/BRZ (1 IN PAN, 1 ON FLOOR). 4. EXHAUST FAN, 339-01-01 SHALL SHUT OFF BOTH A/C UNITS, OUTSIDE BRONZE, 4.1. EXHAUST AIR FAN SHALL RUN CONTINUOUSLY. AIR FAN, AND RETURN AIR FAN REGARDLESS BALL VALVE WATTS B-6000-SS NOTES of THEIR MODE OF OPERATION. BREAK GLASS KEY PLAN: MUST BE MANUALLY RESET. CHECK VALVE BRONZE,WATTS LFWCVS 1. ALL GLYCOL PIPING SHALL BE TYPE 'L' COPPER, WITH BRAZED CONNECTIONS = -- - � (SOLDER CONNECTIONS NOT ALLOWED). 2. ALL VALVES, THERMOMETERS, PRESSURE GAUGES, UNIONS, ETC. TO BE ABOVE STEEL AIR VENT WITH U-BEND TYP DUNNAGE GRATING. y UNION LIEBERT COMMON ALARM EVENTS LIST NOTES ' 3. PROVIDE BRASS TAGS ON ALL VALVES. SEE VALVE CHART FOR NUMBERING. 1 \ T -�i� WATTS LF3001A 4. VALVE CHART & DIAGRAM TO BE LAMINATED AND POSTED IN THE MER. ' D D = DI-ELECTRIC 5. PROVIDE PHENOLIC NAMEPLATES ON DRYCOOLERS & PUMP PACKAGES (MIN. 1" TALL1. CONFIRM TERMINATION LOCATION WITH A/C UNIT DRAIN RELIEF VALVE (PIPED TO WHITE LETTERING ON BLACK BACKGROUND). z= g j M Z MANUFACTURER. a B&G 790-50 6. DIELECTRIC UNIONS TO BE USED AT ALL DISSIMILAR METAL JOINTS. NO EXCEPTIONS. a Q „ Y ROOF/FLOOR DRAIN) a �- 2. CONTROLS CONTRACTOR RESPONSIBLE FOR ALL LOW 7. PROVIDE MANUAL INDOOR AIR VENTS. Z a ~¢ E3 DRAIN VALVE W/BRASS BRONZE, 8. DO NOT BLOCK A/C UNIT ACCESS PANELS WITH PIPING & CONDUIT DROPS OR SST oo zo ¢ VOLTAGE CONDUIT AND WIRING TO MAKE THIS A FULLY CAP TYP PAN. O FUNCTIONAL SYSTEM. 9. OUTDOOR GLYCOL PIPING TO BE UNINSULATED. ro W.E. ANDERSON EVENT o Q EVENT 0 g LOW LEVEL ALARM 10. INDOOR GLYCOL PIPING TO BE INSULATED. 0 Q EVENT o0 Q 3. ALL LOW VOLTAGE WIRING, UNLESS NOTED OTHERWISE L6EPB-B-S-3-B 11. DRYCOOLERS & PUMP PACKAGES TO BE BOLTED (HAND TIGHT) TO STEEL DUNNAGE MAIN FAN OVERLOADTO BE #14AWG IN 1 EMT CONDUIT. WATER UNDER FLOOR C) CONDENSATE 2 FAILURE S TO PREVENT LATERAL MOVEMENT. ICl SOLENOID VALVE TYP 12. THE ENTIRE PIPING SYSTEM IS TO BE PRESSURE TESTED PRIOR TO FILLING WITH LOSS OF AIRFLOW 0C COND PUMP-HIGH WATER O EC FAN FAULT ® 4. CONTROLS PRICING SHALL BE ATTAINED FROM AREA OF WORK roGLYCOL. THE PIPING SYSTEM IS TO HOLD 1.5x THE WORKING PRESSURE OR 125 CLOGGED FILTERS LOSS OF FLOW ® HIGH SUP TEMP ® CONTROLS CONCEPTS NY. ♦- �► FLOW ARROWS - PSIG (WHICHEVER IS LARGER) FOR A TWO-HOUR PERIOD WITH ZERO PRESSURE HIGH ROOM TEMP C) STBY GLYCOL PUMP ON 0 LOW SUP TEMP LOSS. TEST IS TO BE WITNESSED BY ARCHITECT, ENGINEER OR BUILDING WATCH LOW ROOM TEMP01 5. MECHANICAL CONTRACTOR SHALL COORDINATE WITH ENGINEER. STANDBY UNIT ON ® REDUCED ECO AIRFLOW CONTROLS CONTRACTOR, TO AVOID DUPLICATE PRICING. STRAINER W/BALL VALVE BRONZE, 13. PIPE MARKERS TO BE USED INSIDE AND OUTSIDE EVERY 8 FEET ON ALL PIPING. HIGH ROOM HUM ® HUMIDIFIER PROBLEM ® ECO HI TEMP OVERRIDE BLOW DOWN & BRASS CAP WATTS LF777-M1 MARKERS TO BE SETON "SETMARK" DIRECTIONAL SNAP-AROUND PIPE MARKERS. LOW ROOM HUM ® NO CONNECTION W/UNIT1 ® TEMP CTRL SENSOR FAIL 0 6. ALL ALARMS TO BE INSTALLED IN STRICT ACCORDANCE AIRTROL VALVE (SUPPLIED B&G ATF 14. ONE PULLEY CHANGE (MATERIAL AND LABOR) IS PART OF THE BASE JOB TO OBTAIN HIGH TEMP SENSOR A WITH THE MOST CURRENT EDITION OF THE VERIZON BY LIEBERT) DESIGN AIRFLOWS. UNIT X DISCONNECTED HIGH DEW POINT BUILDING ALARM SYSTEMS STANDARD. 15. LAYOUT OF PIPING ON PLAN IS TO BE USED FOR REFERENCE ONLY. SUBMIT PIPING LOW TEMP SENSOR A ® LOSS OF POWER 0 LOW DEW POINT -C IN-LINE AIR SEPARATOR B&G IAS LAYOUT DRAWING TO ENGINEER FOR APPROVAL. HIGH HUM SENSOR A ® CUSTOMER INPUT 1 HI DEW POINT SENSOR A �! 16. SCREW A 1/2 STAINLESS STEEL WIRE MESH SCREEN ON THE UNDERSIDE OF THE LOW HUM SENSOR A 01 CUSTOMER INPUT 2 C. LOW DEW POINT SENSOR A ve r Ei DIFFERENTIAL PRESSURE PENN JOHNSON CTRLS, DUAL PUMP PACKAGE TO PREVENT PIGEONS FROM NESTING. COMP 1 OVERLOAD ® CUSTOMER INPUT 3 dP 17. GLYCOL TO BE A PRE-MIXED 40% PROPYLENE MIXTURE. HIGH REMOTE SENSOR SWITCH MODEL P74FA-1 18. MOUNT dP SENSOR INSIDE DRYCOOLER. PIPE CAPILLARY TUBES TO COMMON SUCTION COMP 2 OVERLOAD CUSTOMER INPUT 4 POWER "A" FAILURE 01 n & DISCHARGE FITTINGS ACROSS THE DUAL GLYCOL PUMPS. WIRE TO TERMINALS 74 COMP 1 HIGH PRESSURE CALL SERVICE F FLOW REGULATING VALVE BRONZE, 0 POWER "B" FAILURE WATTS CSM-61-M 1-S & 77 INSIDE DRYCOOLER. COMP 2 HIGH PRESSURE ® HIGH TEMPERATURE " AIRFLOW SENSOR FAILURE C*O FOR FURTHER INFORMATION REGARDING COMP 1 LOW PRESSURE Q LOSS OF AIR BLOWER 1 ® " HUM CTRL SENSOR FAIL CONTROLS PLEASE CONTACT NICK ZEOLI A/C REPLACEMENT VALVE CHART COMP 2 LOW PRESSURE ® REHEAT LOCKOUT ®® OF CONTROLS CONCEPTS AT: COMP 1 PUMPDOWN FAIL ® HUMIDIFIER LOCKOUT () LOSS OF FLOW FOR CARRIER SWRM ® STAT PRIES SENSOR FAIL CONTROLS CONCEPTS NY VALVE VALVE VALVE COMP 2 PUMPDOWN FAIL ® 30 HOWARD PLACE, SUITE C NO. DESCRIPTION SERVICE LOCATION NO DESCRIPTION SERVICE LOCATION NO DESCRIPTION SERVICE LOCATION ® FC LOCKOUT () LOW STATIC PRESSURE RONKONKOMA, NY 11779 DIG SCROLLI HIGH TEMP 1011 OMPRESSORS) LOCKOUT C) HIGH STATIC PRESSURE PH: (631) 600-3733 1 BALL VALVE GLYCOL MER 10 BALL VALVE PUMP "A" ROOF 19 BALL VALVE FLOW REG. VALVE ROOF DIG SCROLL2 HIGH TEMP 101 COMP 1 SHORT CYCLE STATPRES OUT OF RANGE 0 FAX: (631) 467-8708 SUPPLY LINE SUCTION LINE ISOLATION PUMP "B" EL HEAT HIGH TEMP 0 COMP 2 SHORT CYCLE ® BMS DISCONNECTED p 1755 MAIN RD. GLYCOL 2 DRAIN VALVE MER 11 BALL VALVE ROOF 20 BALL VALVE EXPANSION TANK ROOF WORKING HRS EXCEEDED ® NO POWER ®® CUTCHOGUE, NY SUPPLY LINE SUCTION LINE SIGHT GLASS GLYCOL STRAINER BLOW-OUT SMOKE DETECTED �® CONDENSATE 1 FAILURE p GROUND FLOOR 3 DRAIN VALVE MER 12 BALL VALVE ROOF 21 BALL VALVE EXPANSION TANK ROOF TITLE: RETURN LINE (PUMP A ) SIGHT GLASS GLYCOL PIPING 4 BALL VALVE GLYCOL MER 13 BALL VALVE STRAINER BLOW-OUT ROOF 22 DRAIN VALVE EXPANSION ROOF RETURN LINE (PUMP B ) TANK DRAIN DIAGRAM & SEQUENCE DRYCOOLER PUMP "A" OF OPERATIONS 5 BALL VALVE HI-TEMP LINE ROOF 14 CHECK VALVE DISCHARGE LINE ROOF 23 BALL VALVE EXPANSION TANK ROOF DRYCOOLER PUMP "B" DATE: 8/16/17 6 DRAIN VALVE HI-TEMP LINE ROOF 15 CHECK VALVE DISCHARGE LINE ROOF 24 AIRTROL VALVE EXPANSION TANK ROOF PROJECT NO: 17-2165 7 DRAIN VALVE DRYCOOLER ROOF 16 BALL VALVE PUMP "A" ROOF 25 RELIEF VALVE EXPANSION TANK ROOF DRAWN BY: EAB LO-TEMP LINE DISCHARGE LINE 8 BALL VALVE DRYCOOLER ROOF 17 BALL VALVE PUMP "B" ROOF CHECKED BY: KJH / PEJSCALE: NONE LO-TEMP LINE DISCHARGE LINE 9 DRAIN VALVE -LINE AIR ROOF 18 FLOW REG. VALVE PUMP "A" & "B" ROOF DRAWING NO: SEPARATOR DISCHARGE LINE ' 0 ' . 00 1 GLYCOL PIPING DIAGRAM. 2 SEQUENCE OF OPERATIONS SCALE KT.S► SCALE NOPE SHEET NO: 6 OF 9 $ - PRECISION AIR CONDITIONING UNIT SCHEDULE CAPACITYRETURN AIR GLY FAN SECTION ELECTRICAL DATA FILTER SECTION PIPE CONN (IN) ECONO SCOP FLOW dP COMP REHEAT HUMID WGT DIMENSIONS UNIT NO SEN TOT I TONS COIL —127 TDB TWB RATE (FT H2O) QTY/ CFM SP QTY BLOWER QTY MOTOR COIL CAP CAP WXDXH MFR, MODEL NO (MBH) (MBH) (NOM) ('F) ('F) (GPM) EFF. TYPE CFM (IN WG) FANS SIZE MOTORS HP (KW) (LBS/HR) V/PH/HZ FLA WSA MFCB TYPE QTY SIZE MERV IN OUT (LBS) (IN) PRE 6 25x2Ox2 MERV 313-01-01, 2/ 8 (1) ® (1) ® LIEBERT DS 2 Y8 313-01-02 142.0 198.0 15 YES 2.01 80 67 50 24 SCROLL 6,000 1.0 2 15x11 1 NC. E NONE 208/3/60 74.8 82.8 1 10 2,550 109x35x76 MAIN 6 25x20x4 MERV 2-Y8 VS053K (GLYCOOL) 11 SPECIAL FEATURES: • UPFLOW, FRONT RETURN, FRONT FAN DISCHARGE UNIT—MOUNTED DISCONNECT SWITCH 0 3 REMOTE SHUTDOWN TERMINALS COLOR: ZP-7021A Jacobsen & Horan • 40% PROPYLENE GLYCOL SOLUTION 3-WAY GLYCOL CONTROL VALVE 3 LIQUITECT SHUTDOWN TERMINALS • 6" FLOOR STAND WITH NEOPRENE PADS i-COM CONTROLLER WITH SERVICE BRACKET 0 LEAK DETECTORS (LIEBERT LT410 - 2 PER A/C UNIT) • DIGITAL SCROLL COMPRESSORS INTELLISLOT IS-UNITY CARD/WEB L FACTORY-INSTALLED INSIDE A/C UNIT 0 2 SPARE SETS OF FILTERS PER UNIT • DOUBLE WALL CONSTRUCTION 3 COMMON ALARM TERMINAL OUTPUTS • REMOTE TEMPERATURE SENSOR W/ 150' OF CABLE Engineering, P.C. 990 South 2nd Street Ronkonkoma, NY 11779 O: (631) 580-6100 DRYCOOLER SCHEDULE F: (631) 01 www.jhepc.coc.co com UNIT TOTAL HEAT AMB GLYCOL FANS ELECTRICAL DATA PIPE CONN WGT DIMENSIONS UNIT NO REJECTION TEMP ENT LVG dP CFM HP/ * * * SUCT DISCH LBS LxWxH MFR & MODEL NO REMARKS QF NEw " IT IS WARNING NI VIOLATION OF NEW YORK SERVED CAP (MBH) (F) (F) (F) GPM (� H2O) (TOTAL) QTY EA V PH HZ FLA WSA MFCB (IN) (IN) ( ) (IN) ,�`Ci ��{ JSTATE / / �/0 PERSON, UNLESS CTINGOUNDER THE DIRECTION OF A LICENSED 210-1 R-01, 313-01-01, (1) ® (1) ® 171.5x44 15 GALLON co -9 PROFESSIONAL ENGINEER, TO 256 105 122 110 50 10 21,700 4 0.75 208/3/60 24.6 27.3 35 1,100 LIEBERT DD0491 Y32 a 2 ALTER AN ITEM ON THIS DRAWING 210-1 R-02 313-01-02 248 2—X x43 ASME COMPRESSION TANK IN ANY WAY. IF AN ITEM IS �f LALTERED, THE ALTERING ENGINEER { LLI SHALL AFFIX TO THE ITEM M LU HIS/HER SEAL AND THE NOTATION ALTERED BY' FOLLOWED BY PUMP AND DRYCOOLER I-tS Fp .� HIS/HER SIGNATURE AND THE�735� �Ci,y DATE OF SUCH ALTERATION AND A A OFESSIONP SP��nONESCRIPTION OF THE PUMP SCHEDULE R CONSULTANT: PIPE CONN ELECTRICAL DATADIMENSIONS � � �1,r: 12-1 TECHNOLOGY DRIVE UNIT NO SERVICE GPM TDH RPM MOTOR SUCT ` DISCH TYPE WGT LxWxH MFR & MODEL NO SETAUKET, NY 11733 P. 631.689.8450 (IN) (IN) (IN) (FT H2O) HP VPH HZ FLA (LBS) F. 631.689.8459 / / www.wfcaia.com 474-1 R-01/02, 313-01-01, DUAL GLYCOOL 50 103 3,500 3 1-1/2 1 208/3/60 10.6 CENTRIFUGAL 500 32.5x3Ox19 LIEBERT, D3YNT 474-1R-03/04 313-01-02 PUMP PKG 1 T E C T S NO. DATE SUBMISSION FAN SCHEDULE 1 10/10/17 ISSUED FOR BID 2 11/02/17 ISSUED FOR FILING AIRFLOW EXT. SP MOTOR WGT DIMENSIONS UNIT NO SERVICE (CFM) (IN WG) RPM HP FLA TYPE SERVICE RPM ARRANGEMENT TYPE MFR & MODEL NO (LBS) WxHxD ACCESSORIES (IN) VARI—GREEN EC MOTOR W/ MOUNTED & WIRED POTENTIOMETER EXHAUST WALL SIDEWALL GREENHECK, DIAL, NEMA-1 TOGGLE SWITCH MOUNTED & WIRED, PERMATECTOR 339-01-01 AIR 500 0.3 1,224 y4 5.8 ODP 115/1/60 1,725 MOUNT DIRECT—DRIVE SE1—1 2-432—VG 44 18 x 18 x 10.75 COATING (CONCRETE GRAY), MOTOR ACCESS FROM INTERIOR OF BLDG DIRECT—DRIVE VARI—GREEN EC MOTOR W/ MOUNTED & WIRED POTENTIOMETER 340-01-01 RETURN 1,200 0.7 1,461 Y2 9.8 ODP 115/1/60 1,725 HORIZONTAL CENTRIFUGAL GREENHECK, SQ-120—VG 66 19 x 19 x 24 DIAL, NEMA-1 TOGGLE SWITCH MOUNTED & WIRED, PERMATECTOR AIR CEILING HUNG IN—LINE FAN COATING (CONCRETE GRAY), STAINLESS STEEL FASTENERS, SPRING HANGING ISOLATORS & BRACKETS, OUTLET GUARD DIRECT—DRIVE VARI—GREEN EC MOTOR W/ MOUNITED & WIRED POTENTIOMETER 341-01-01 OUTSIDE 1,000 0.6 1,575 Y4 5.8 ODP 115/1/60 1,725 HORIZONTAL CENTRIFUGAL GREENHECK, SQ-100—VG 47 17 x 17 x 24 DIAL, NEMA-1 TOGGLE SWITCH MOUNTED & WIRED, PERMATECTOR AIR CEILING HUNG IN—LINE FAN COATING (CONCRETE GRAY), STAINLESS STEEL FASTENERS, SPRING KEY PLAN: HANGING ISOLATORS & BRACKETS, OUTLET GUARD 3� y FILTER ASSEMBLY SCHEDULE SIZE (IN) PREFILTER MAIN FILTER I! UNIT NO MFG TYPE MODEL NO. WIDTH HEIGHT QTY SIZE EFF MFG MODEL NO QTY SIZE EFF MFG MODEL NO F-1 CAMFIL GLIDEPACK GP MT131 1HX1W 23.38 27.25 1 24242 30% CAMFIL 30/30 1 24244 80% CAMFIL OPMV13 OPTIONS: DOUBLE WALL INSULATION, TWO 2 HINGED ACCESS DOORS, HANGER BRACKETS, STATIC TAPS, MAGNEHELIC SERIES 2000 EXTERNAL DP GAUGE MOUNT GAUGE ; AND TUBING SO THAT LOCATION DOES NOT INTERFERE WITH THE REMOVAL OF SIDE SERVICE PANELS OR ACCESS TO ANY OTHER ANCILLARY EQUIPMENT) i AIR DEVICE SCHEDULE AREA OF WORK SIZE DESIGN TAG TYPE WIDTH LENGTH NECK MOUNT MANUFACTURER DIRECTION MODEL FLOW RATE RANGE REMARKS (IN) (IN) (IN) (CFM) DL-1 DRUM LOUVER 24 6 - SURFACE ANEMOSTAT - IJ 1000 ALUMINUM, WHITE FINISH, ADJUSTABLE DRUM DIRECTIONAL BLADES, OBVD w(a SR-1 SUPPLY REGISTER 12 12 - SURFACE ANEMOSTAT - 25/L 250 20 GA. STEEL, WHITE FINISH, W OBVD, DOUBLE DEFLECTION, Y" BLADE SPACING RG-1 RETURN GRILLE 12 10 - SURFACE ANEMOSTAT - 35/L/O 400 20 GA. STEEL, WHITE FINISH, Y2" BLADE SPACING, 0- DEFLECTION RG-2 RETURN GRILLE 12 12 - SURFACE ANEMOSTAT - GC5 500 GRID CORE, 20 GA. STEEL, WHITE FINISH, Y2" BLADE SPACING, 0' DEFLECTION A/C REPLACEMENT TG-1 TRANSFER GRILLE 16 10 - SURFACE ANEMOSTAT - 15/L 400 20 GA. STEEL, WHITE FINISH, W OBVD, FOR CARRIER SWRM SINGLE DEFLECTION, Y2 BLADE SPACING LOUVER SCHEDULE 31755 MAIN RD. DIMENSIONS UT HO UE, NY (IN) AIRFLOW FREE AREA PRESSURE GROUND FLOOR UNIT NO TYPE (CFM) (%) DROP DRAINABLE FINISH MANUFACTURER MODEL WIDTH WEIGHT DEPTH (INWG) TITLE: L-1 24* 24* 4 EXTERIOR WALL 500 37.5 — YES BRONZE ANODIZED C/S GROUP A4097 SCHEDULES * VERIFY EXACT DIMENSIONS IN FIELD PRIOR TO ORDERING. DATE: 8/16/17 PROJECT NO: 17-2165 DRAWN BY: EAB CHECKED BY: KJH / PEJ SCALE: NONE DRAWING NO: 1 SCHEDULES [Am601'" e00 SCALE NONE SHEET NO: 7 OF 9 EQUIPMENT LABEL AND PIPE MARKER SCHEDULE MINIMUM PIPE INSULATION THICKNESS (THICKNESS IN INCHES) THE FOLLOWING LABELS AND MARKERS SHALL BE PROVIDED. LABELS SHALL BE PHENOLIC PLATES WITH ADHESIVE BACKING AND ADHERED TO A LOCATION ON THE PIECE OF EQUIPMENT THAT DOES NOT AFFECT IT'S OPERATION OR SERVICEABILITY. PIPE MARKERS SHALL BE SETON 'SETMARK' SNAP-AROUND STYLE WITH NYLON TIES (IF REQUIRED). LABELS AND MARKERS SHALL BE IN AN EASILY READABLE POSITION. COORDINATE INSULATION CONDUCTIVITY NOMINAL PIPE OR TUBE SIZE (INCHES) ALL NOMENCLATURE WITH THE VERIZON PROPERTY MANAGER PRIOR TO ORDERING. SUBMIT A LABEL SCHEDULE TO THE ENGINEER FOR APPROVAL AFTER COORDINATION WITH THE PROPERTY MANAGER. THE FLUID OPERATING CONTRACTOR IS RESPONSIBLE FOR ANY ADDITIONAL LABELS AND MARKERS REQUIRED BY CODE OR OUTLINED ON THE SPECIFICATION SHEET. LABELS DENOTED WITH "-XX" ARE TO BE FIELD DETERMINED. TEMPERATURE RANGE AND CONDUCTIVITY MEAN RATING LETTERING USAGE ('F) BTU *IN./(H*FT2*'F) TEMPERATURE, 'F < 1 1 TO < 1-1/2 1-1/2 TO < 4 4 TO < 8 > 8 DEVICE TYPE LABEL TEXT BACKGROUND COLOR COLOR HEIGHT (IN) > 350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 A/C UNIT PHENOLIC PLATE 313-01-01 WHITE 1 BLACK 251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5 A/C UNIT PHENOLIC PLATE 313-01-02 WHITE 1 BLACK 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3,0 Jacobsen & Horan RETURN AIR FAN PHENOLIC PLATE 340-01-01 WHITE 1 BLACK 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 Engineering, P.C. 990 South 2nd Street OUTSIDE AIR FAN PHENOLIC PLATE 341-01-01 WHITE 1 BLACK 105-140 0.21-0.28 100 1.0 1.0 1.5 1.5 1.5 Ronkonkoma, NY 11779 O: (631) 580-6100 EXHAUST AIR FAN PHENOLIC PLATE 339-01-01 WHITE 1 BLACK 40-60 0.21-0.27 75 0.5 0.5 1.0 1.0 1.0 F: (631) 580-6101 TEMPERATURE SENSOR PHENOLIC PLATE 313-01-01 WHITE Y2 BLACK < 40 0.20-0.26 50 0.5 1.0 1.0 1.0 1.5 www.jhepc.com SPACE TEMP. SENSOR WARNIN313-01-02 N E(N IT I VIOLATION OF NEW YORK TEMPERATURE SENSOR PHENOLIC PLATE WHITE Y2 BLACK Q STATE EDUCATION LAW FOR ANY SPACE TEMP. SENSOR � CH J. H Y0 PERSON, UNLESS ACTING UNDER DRYCOOLER PHENOLIC PLATE 210-1R-01 WHITE 1 BLACK ��� Oty�� THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO SERVES 313-01-01 ALTER AN ITEM ON THIS DRAWING �C IN ANY WAY. IF AN ITEM IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM DRYCOOLER PHENOLIC PLATE 210-1R-02 WHITE 1 BLACK Y HIS/HER SEAL AND THE NOTATION Z ALTERED BY' FOLLOWED BY SERVES 313-01-02 � HIS/HER SIGNATURE AND THE dip3 DATE OF SUCH ALTERATION AND A 474-1 R-01 & Fp 07351 �,� SPECIFIC DESCRIPTION OF THE PUMP PACKAGE PHENOLIC PLATE 474-1R-02 WHITE 1 BLACK Ap SNP ALTERATION. PUMP PACKAGE PHENOLIC PLATE 474-1 R-03 & WHITE 1 BLACK CONSULTANT: 474-1 R-04 ;, 12-1 TECHNOLOGY DRIVE, SETAUKET, NY 11733 BAS PANEL PHENOLIC PLATE 650-01-01 WHITE 1 BLACK P. 631.689.8450 y F. 631.689.8459 s www.wfcaia.com LEAK DETECTORS PHENOLIC PLATE LEAK DETECTOR WHITE 1 BLACK I T E C T S CONDENSATE PIPE MARKER CONDENSATE WHITE VARIES GREEN GLYCOL SUPPLY PIPES PIPE MARKER GLYCOL SUPPLY BLACK 1 YELLOW NO. DATE SUBMISSION (WITH FLOW ARROW) 1 10/10/17 ISSUED FOR BID GLYCOL RETURN PIPES PIPE MARKER GLYCOL RETURN BLACK 1 YELLOW 2 11/02/17 ISSUED FOR FILING (WITH FLOW ARROW) DOMESTIC COLD WATER PIPES PIPE MARKER DOMESTIC COLD WATER WHITE VARIES GREEN (WITH FLOW ARROWS) TESTING, ADJUSTING + BALANCING SPECIFICATION 1. TESTING, ADJUSTING AND BALANCING: 7.1. A/C UNIT SHUTDOWN WILL REQUIRE SPECIFIC MOP AND OUT OF HOURS 1.1. PERFORM AIR BALANCE' ON: WORK BY THE MECHANICAL CONTRACTOR. 1.1.1. TWO (2) A/C SYSTEMS, 313-01-01 AND 313-01-02. 1.1.2. ONE (1) RETURN AIR FAN, 340-01-01. 8. PERFORM FINAL TEST WITH DAMPERS, GRILLES, AIR DEVICES AND ALL OTHER 1.1.3. ONE (1) OUTSIDE AIR FAN, 341-01-01. DEVICES IN THEIR ADJUSTED AND FINAL POSITIONS. 1.2. PERFORM WATER BALANCE ON: KEY PLAN: 1.2.1. GLYCOL SYSTEM. 9. MEASURE AND REPORT OVERALL SYSTEM FINAL CONDITIONS (NUMBER OF COMPRESSORS OPERATING, ALARMS PRESENT, ETC.). 2. REPORTING: ON A MINIMUMI OF TWO (2) SEPARATE OCCASIONS (INITIAL AND 10. INITIAL AIR SURVEY AND FINAL BALANCING TO INCLUDE THE FOLLOWING: FINAL), PROVIDE THE ENGIti�IEER WITH A PDF FILE OF THE BALANCING REPORT FOR REVIEW/APPROVAL. 10.1. NEW A/C UNITS (313-01-01 AND 313-01-02). RETURN FAN i= (340-01-01) AND OUTSIDE AIR FAN (341-01-01) ADJUSTING AND 3. AIR BALANCER TO ALLOW FOR A MINIMUM OF TWO (2) ON-SITE VISITS FOR BALANCING: AN INITIAL AND FINAL AIR BALANCE. 10.1.1. INDIVIDUALLY BALANCE THE NEW A/C SYSTEMS & FANS TO THEIR 3.1. INITIAL AIR BALANCE: IT IS THE INTENT OF THIS SPECIFICATION THAT AN DESIGN AIRFLOWS. "f� INITIAL AIR BALANCE BE PERFORMED AT THE START-UP OF THE NEW 10.1.2. MEASURE AND REPORT THE FOLLOWING FOR THE A/C UNITS & FANS: UNITS. ALL NEW AND EXISTING AIR DEVICES SHALL HAVE THEIR FLOWS 10.1.2.1. ALL MOTOR NAMEPLATE INFO (HP, VOLTS, PHASE, FRAME, SF, RECORDED; ALL INDICATED TRAVERSE POINTS TO BE TAKEN. ETC.) \\.�. �a U 10.1.2.2. FAN BELT SIZE(S) & QUANTITY OF EACH 3.2. FINAL AIR BALANCE: AFTER THE RESULTS HAVE BEEN REVIEWED BY THE 10.1.2.3. PULLEY SIZE FOR ALL FANS (INITIAL & FINAL) 'A ENGINEER, IT SHALL BE DETERMINED IF A BELT AND PULLEY CHANGE IS REQUIRED TO ACHIEVE DESIRED AIRFLOW. ONCE THE BELT AND PULLEY 10.1.2.4. TOTAL AIRFLOW, CFM (SUPPLY AND RETURN) CHANGE HAS TAKEN PLACE, A FINAL BALANCE SHALL BE PERFORMED. 10.1.2.5. FAN SPEED, RPM 10.1.2.6. FAN MOTOR SPEED, RPM ABPA OF WORK 4. ALL BALANCING TO BE COMPLETED AND APPROVED PRIOR TO THE 10.1.2.7. FAN DISCHARGE PRESSURE, INWG ENGINEERING PUNCH OUT. 10.1.2.8. FAN SUCTION PRESSURE, INWG 10.1.2.9. PRESSURE DROP ACROSS THE FILTERS, INWG 5. IT IS THE BALANCER'S RESPONSIBILITY TO IDENTIFY OBSERVED DEVIATIONS 10.1.2.10. OVERALL STATIC PRESSURE, INWG FROM THE CONSTRUCTION DRAWINGS ON THE INITIAL BALANCE REPORT (E.G. 10.1.2.11. AMPERAGE READINGS FOR THE SUPPLY FAN MOTOR, AMPS CAPPED OR MISSING AIR DEVICES, BROKEN VOLUME DAMPERS, CLOSED 11. FINAL SEQUENCE OF OPERATION: FIRE/SMOKE DAMPERS, ETC.). 11.1. ONCE ALL BALANCING HAS BEEN COMPLETED, THE FOLLOWING EQUIPMENT IIm 6. FINAL AIRFLOW VALUE TOLERANCES: SHALL BE LEFT IN OPERATION: 6.1. EACH AIR DEVICE 1 1.1.1. TWO (2) A/C UNITS (313-01-01 AND 313-01--02) AT THEIR 6.1.1. TO WITHIN 0 TO 10% OVER DESIGN AIRFLOW RATES. RESPECTIVE DESIGN AIRFLOWS.6.2. AT DUCT TRAVERSE POINTS 11.1.2. ONE (1) RETURN AIR FAN (340-01-01).6.2.1. TO WITHIN 0 TO 57. OVER DESIGN AIRFLOW RATES. 11.1.3. ONE (1) OUTSIDE AIR FAN (341-01-01). 7. BALANCER IS REQUIRED, A5 PART OF THE BASE BID, TO COORDINATE ,WITH 12. INCLUDE APPENDICES FOR: THE MECHANICAL CONTRACTOR AND THE EQUIPMENT MANUFACTURER TO 12.1. RAW FIELD DATA TAKEN DURING TESTING. CHANGE OUT BELTS AND PULLEYS AS REQUIRED TO OBTAIN THE FINAL 12.2. SAMPLE CONVERTRAWCALCULATION SHEET DATA INTO FINAL EACH TYPE I AL RESULTSO (I EA TRAVERSE READINGTION MADE S). A/C REPLACEMENT AIRFLOW RATES FROM ALL HVAC EQUIPMENT. ALL LABOR AND MATERIALS TO CONTRACTOR'SACCOMPLISH HIS TASK BASE BIDISINCOBE INCLUDED IN LUD NG ANY REQUIRED MECHANICAL EQUIPMENT SHUTDOWNS. 12 3 DEVICIEEREADINGS (WEREDTAKEING WHERE E TRAVERSE POINTS AND AIR FOR CARRIER SWRM 31755 MAIN RD. CUTCHOGUE, NY GROUND FLOOR TITLE: SCHEDULES & TAB SPECIFICATION DATE: 8/16/17 PROJECT NO: 17-2165 DRAWN BY: EAB CHECKED BY: KJH / PEJ SCALE: NONE DRAWING NO: 1 SCHEDULES M 6 0 0 SCALE NOPE SHEET NO: 8 OF 9 1. GENERAL INDICATING IN A NEAT AND ACCURATE MANNER, A COMPLETE RECORD OF ALL REVISIONS 4.2. HVAC: ALL PIPES 1-1/2" IN DIAMETER AND LARGER, SHALL HAVE THEIR FINAL CONNECTIONS & PROGRAMMING. CONTRACTOR SHALL PROVIDE & MOUNT A LAMINATED COPY OF CONTROL TO THE ORIGINAL DESIGN OF THE WORK. TO APPARATUS MADE WITH COMPANION FLANGES. PIPE SMALLER THAN 1-1/2" IN DIAMETER DIAGRAM & OPERATION SEQUENCE IN MECHANICAL ROOM. 1.1. SCOPE OF WORK SHALL BE CONNECTED WITH SCREWED, GROUND JOINT UNIONS. INSTALL LINE SIZE MANUAL 1.1.1. WORK UNDER THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIAL, FURNISHED AND 1.15. OPERATING AND MAINTENANCE MANUALS VALVES AT EACH INLET AND OUTLET OF EACH PIECE OF EQUIPMENT. 7.7. ALL LOW VOLTAGE (:<24V) CONTROL WIRING SHALL BE THE RESPONSIBILITY OF THE INSTALLED AS IMPLIED BY THE MECHANICAL DRAWINGS. THE WORK IN GENERAL IS LISTED 1.15.1. ON COMPLETION AND ACCEPTANCE OF THE WORK, FURNISH TO THE ENGINEER FOR MECHANICAL CONTRACTOR. AS FOLLOWS: HVAC EQUIPMENT & ACCESSORIES, AIR DISTRIBUTION, INSULATION, TESTING, REVIEW 5 COPIES OF WRITTEN INSTRUCTIONS ON THE PROPER OPERATION AND ADJUSTING & BALANCING, PLUMBING, SUPPORT SYSTEMS, VIBRATION ISOLATION AND MAINTENANCE OF ALL EQUIPMENT AND APPARATUS FURNISHED UNDER THIS SECTION, 4.3. COLD, HOT, MAKE—UP WATER AND CONDENSATE DRAIN PIPING SHALL BE TYPE L COPPER ' CONTAINING: TUBING WITH WROUGHT OR CAST COPPER SOLDER FITTINGS. JOINTS SHALL BE MADE WITH 8. VIBRATION ISOLATION & MOUNTING CONTROLS. 95//5 TIN ANTIMONY SOLDER. SOFT TEMPER TYPE 'K' COPPER TUBING SHALL BE USED ON 1.15.2. MANUFACTURER'S MECHANICAL EQUIPMENT PARTS LIST OF ALL FUNCTIONAL COMPONENTS ALL UNDERGROUND OR BURIED PIPING. 8.1. VIBRATION CONTROL SHALL BE ACHIEVED BY USE OF APPROVED VIBRATION ELIMINATORS 1.1.2. ALL APPLICABLE LOCAL, STATE AND NATIONAL CODES, STANDARDS AND REGULATIONS OF THE SYSTEM LISTED ON THE EQUIPMENT SCHEDULES, DRAWINGS, CONTROL & WIRING INSTALLED AS DIRECTED BY THE MANUFACTURER. ISOLATORS SHALL BE OF THE FOLLOWING RELATING OR GOVERNING ANY PORTION OF THIS WORK ARE HEREBY MADE PART OF DIAGRAMS. LIST SHALL GIVE SYSTEM NUMBER, UNIT NUMBER, MANUFACTURER'S MODEL 4.4. REFRIGERANT & GLYCOL PIPING SHALL BE HARD DRAWN TYPE 'L' OR 'ACR' COPPER TUBING TYPES: DOUBLE DEFLECTION MOUNTINGS, SPRING HANGERS, UN—HOUSED & HOUSED SPRING THESE SPECIFICATIONS INCLUDING BUT NOT LIMITED TO OSHA, NFPA 90A, SMACNA, NUMBER, AND MANUFACTURER'S DRAWING NUMBER. WITH WROUGHT COPPER FITTINGS JOINED BY BRAZING USING FILLER METALS MEETING AWS MOUNTINGS, ISOLATION BASES, ISOLATION RAILS, CURB—MOUNTED BASES & RUBBER MATS. N.Y.S. ENERGY CODE AND ASHRAE. 1.15.3. CLEAN COPY OF EACH FULLY PROCESSED SHOP DRAWING. A5.8 SPECIFICATION. ALL ELLS SHALL HAVE LONG RADIUS SWEEP. PROVIDE MANUFACTURER RECOMMENDED ACCESSORIES, PITCH SUCTION GAS PIPING TOWARD COMPRESSOR. 8.2. TOTAL RATED CAPACITY OF ISOLATORS SHALL BE AT LEAST 150 PERCENT OF THE WEIGHT OF 1.2. EXAMINATION OF EXISTING CONDITIONS 2. DUCTWORK & ACCESSORIES THE EQUIPMENT SUPPORTED. 1.2.1. VISIT AND CAREFULLY EXAMINE THOSE PORTIONS OF THE SITE AND/OR PRESENT 4.5. SOUL, WASTE AND VENT PIPING WITHIN BUILDING SHALL BE "NO—HUB" CAST IRON WITH BUILDINGS AFFECTED BY THIS WORK SO AS TO BECOME FAMILIAR WITH EXISTING 2.1. ALL DUCTWORK, EXCEPT WHERE SPECIFICALLY NOTED, SHALL BE CONSTRUCTED OF NEW "NO—HUB" FITTINGS. JOINTS SHALL BE MADE WITH ELASTOMERIC COLLARS SECURED BY 8.3. PROVIDE ISOLATION EQUIPMENT MADE BY EITHER MASON INDUSTRIES OR VIBRATION Jacobsen & Horan CONDITIONS AND DIFFICULTIES ASSOCIATED WITH THE EXECUTION OF THE WORK, BEFORE G-60 COATED GALVANIZED STEEL OF LOCK—FORMING GRADE IN ACCORDANCE WITH THE STAINLESS STEEL BANDS AND CLAMPS, AS MANUFACTURED BY CLAMP—ALL "125" OR HUSKY ELIMINATOR COMPANY. SUBMITTING PROPOSALS. RECOMMENDATIONS LISTED IN THE CURRENT EDITION OF SMACNA s: HVAC DUCT CONSTRUCTION STANDARDS, METAL AND FLEXIBLE". "4000". SANITARY DRAINAGE PIPING UNDER GRADE LEVEL SLAB SHALL BE EXTRA—HEAVY 8.4. USE TYPE OF ISOLATORS FOR EQUIPMENT SPECIFIED BELOW UON: 1.2.2. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION CAST IRON SOIL PIPE AND FITTINGS. JOINTS SHALL BE MADE BY COMPRESSION OF A 8.4.1. FLOOR—MOUNTED AIR HANDLING UNITS: UN—HOUSED SPRING MOUNTINGS ON CONCRETE Engineering, P.C. HAS BEEN MADE AND, LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS REQUIRED2.2. ALL DUCTWORK SHALL BE CONSTRUCTED AS 1 MINIMUM PRESSURE CLASSIFICATION UNLESS MOLDED RING OF ELASTOMERIC MATERIAL. BASE. 990 South 2nd Street BECAUSE OF DIFFICULTIES ENCOUNTERED, WHICH COULD HAVE BEEN FORESEEN HAD NOTED OTHERWISE. ALL SIZES SHOWN ON DRAWINGS ARE C! EAR INSIDE DIMENSIONS. SHALL BE SUPPORTED AT PROPER INTERVALS SO THAT DEFLECTION WILL NOT 8.4.2. SUSPENDED IN—LINE FANS, DUCTWORK, PIPING, INLINE PUMPS: SPRING HANGERS. SUCH EXAMINATION BEEN MADE, WILL NOT BE RECOGNIZED. 4.6. ALL PIPES 8.4.3. A/C UNITS & AIR—COOLED CONDENSERS: NEOPRENE RUBBER WAFFLE MAT PAD UNDER Ronkonkoma, NY 11779 SUPPORTS, FASTENERS AND ACCESSORIES SHALL BE GALVANIZED STEEL. EXCEED 1/8 INCH. ON PIPING WHERE A VAPOR BARRIER IS USED, HANGERS SHALL BE LEGS. MAT/ 1.3. TIME AND MANNER OF EXECUTION OF WORK INSTALLED ON THE OUTSIDE OF THE INSULATION WITH A METAL SHIELD TO PROTECT THE O: (631) 580-6100 1.3.1. ALL WORK SHALL BE DONE AS EXPEDITIOUSLY AS POSSIBLE AND IN SUCH A MANNER AS 2.3. ALL DUCTWORK SHALL BE SEALED AIRTIGHT PER SEAL CLASS V. INSULATION. ON OTHER LINES, HANGER SHALL BE INSTALLED IN DIRECT CONTACT WITH 8.5. ALL MECHANICAL EQUIPMENT, WHETHER INSTALLED ON FLOORS OR ROOFS SHALL BE F: (631) 580-6101 NOT TO CAUSE INTERFERENCE OR INTERRUPTION TO THE BUSINESS OF THE TENANT OR 2 4. UNLESS NOTED OTHERWISE, CLINCH COLLARS, OR BOOT TAPS, ARE TO BE INSTALLED AT THE PIPING. PROPERLY BOLTED (PER MANUFACTURER'S RECOMMENDATION) TO EITHER THE SUPPLIED www.jhepc.com OWNER. SUBMIT SCHEDULE FOR REVIEW AND APPROVAL. THE SUBCONTRACTOR SHALL TAP POINT FOR ALL DUCT TAKE—OFFS, BRANCHES AND GRILLES. 4.7. PROVIDE DIELECTRIC FITTINGS AT ALL PIPE CONNECTIONS WHERE DISSIMILAR METALS DUNNAGE, CURBING OR CONCRETE PAD ON WHICH THEY ARE TO REST. NOT OBSTRUCT ENTRANCES OR PASSAGES ON THE OWNER'S PREMISES. INTERFACE. pF µlN A VIOLATION OF NEW YORK 1.3.2. TRANSPORTATION OF MATERIAL INTO AND THROUGH THE BUILDING WILL BE SUBJECT TO 2.5. MANUAL VOLUME DAMPERS 8.6. EQUIPMENT REQUIRING CONDENSATE DRAINAGE SHALL BE INSTALLED AT SUCH AN ELEVATION NEIT IS REVIEW AND APPROVAL OF THE TENANT OR OWNER AND MAY BE LIMITED TO RESTRICTED 2.5.1. ALL BRANCHES AND TAKE—OFFS SHALL BE EQUIPPED W MANUAL VOLUME DAMPERS OF SO AS TO ACCOMMODATE INSTALLATION OF PROPERLY SIZED TRAP. ELEVATION TO BE Y STATE EDUCATION LAW FOR ANY TIMES OUTSIDE OF NORMAL BUSINESS HOURS. / 4.8. PROVIDE ANCHORS & EXPANSION LOOPS TO ACCOUNT FOR PIPE EXPANSION. ACHIEVED THROUGH CONCRETE PAD, FLOOR STAND ETC. ��N J yO 0 PERSON, UNLESS DIRECTION A INN UNDER THE SAME MATERIAL AS THE DUCT IN WHICH THEY ARE INSTALLED. �P�� �9�� PTHE ROFESSIONAL ENGINEER, To 1.4. GENERAL SCOPE OF WORK 2.5.2. DUCTS 6" HIGH OR LESS SHALL HAVE SINGLE BLADE DAMPERS, DUCTS OVER 6" HIGH 4.9. INTERIOR HOSE BIBBS SHALL BE PROVIDED WITH KEYED STOP & WITH VACUUM BREAKER. 9 2 ALTER W ITEM ON THIS DRAWING . ACTUATORS Y � IN ANY WAY. IF AN ITEM IS 1.4.1. THESE SPECIFICATION'S AND DRAWINGS ARE INTENDED TO INCLUDE THE COMPLETE UP TO 12" HIGH SHALL HAVE TWO SINGLE BLADE DAMPERS. DUCTS OVER 12" HIGH PROVIDE A MINIMUM OF ONE BIBB WHEREVER THERE IS A FLOOR DRAIN. ALTERED, THE ALTERING ENGINEER W SHALL AFFIX TO THE ITEM INSTALLATION OF ALL WORK SPECIFIED AND SHOWN ON THE DRAWINGS, INCLUDING BUT SHALL HAVE DAMPERS OF THE MULTI—BLADE TYPE. * f 9.1. ELECTRONIC DIRECT—COUPLED (OVER SHAFT) ACTUATION SHALL BE PROVIDED. n _w HIS/HER SEAL AND THE NOTATION NOT LIMITED TO THE FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT, TOOLS, 2.5.3. ALL VOLUME DAMPERS SHALL HAVE LOCKING QUADRANT HANDLES. WHERE DUCTS ARE 4.10. FLOOR DRAIN SHALL BE JAY R. SMITH #DX2312TB W/ C.I. BODY & NICKEL BRONZE ti' �' Z "ALTERED BY' FOLLOWED BY �'� HIS/HER SIGNATURE AND THE TRANSPORTATION, AND STORAGE. THE DRAWINGS INDICATE SIZES AND GENERAL LOCATIONS INSULATED PROVIDE A STANDOFF BRACKET AND EXTENDED PIN FOR HANDLE MOUNTING ADJUSTABLE 8-1/2" ROUND TOP STRAINER W/ 3/4" GRATE, 3" OUTLET UON. 9.2. THE ACTUATOR SHALL HAVE ELECTRONIC OVERLOAD OR DIGITAL ROTATION SENSING CIRCUITRY �Fp 073513 �� DATE OF SUCH ALTERATION AND A OF WORK. SCALED DIMENSIONS ARE NOT TO BE USED. ANY DIMENSIONS NOT SHOWN BEYOND INSULATION. TO PREVENT DAMAGE TO THE ACTUATOR THROUGHOUT THE ENTIRE ROTATION OF THE � SPECSPECIFIC DESCRIPTION OF THE ESS� SHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS. FOR EXACT LOCATIONS, 4.11. PRIOR TO FILLING, ALL PIPING SHALL BE PRESSURE TESTED TO 1.5 TIMES ITS WORKING ACTUATOR. MECHANICAL END SWITCHES OR MAGNETIC CLUTCH TO DEACTIVATE THE ACTUATOR ,�OF ALTERATION. HEIGHTS, DOOR SWINGS, MOUNTING HEIGHTS, ETC., REFER TO AF'HITECTURAL DRAWINGS. 2.6. WHEN FLEXIBLE AIR DUCTS ARE INDICATED ON DRAWINGS, BETWEEN SUPPLY DUCT AND AIR PRESSURE OR 125 PSIG, WHICHEVER IS LARGER. PRESSURE SHALL HOLD FOR A TWO—HOUR AT THE END OF ROTATION ARE NOT ACCEPTABLE. 1.4.2. THE SUBCONTRACTOR SHALL FURNISH AND INSTALL ALL NEW MATERIALS AND SHALL DEVICE, THEY SHALL NOT EXCEED 5 FEET IN LENGTH. SUCH CONNECTORS SHALL BE CLASS PERIOD WITH ZERO PRESSURE LOSS. TEST SHALL BE WITNESSED BY ARCHITECT, ENGINEER CONSULTANT: REMOVE OR RELOCATE ALL MATERIALS AS NOTED ON THE DRAWINGS. BASED ON OWNERS 2 AND SEALED WITH 3M COMPANY 800 SEALANT AND CLAMPED WITH "IDEAL" TYPE 52 OR BUILDING WATCH ENGINEER. 9.3. FOR POWER—FAILURE/SAFETY APPLICATIONS, AN INTERNAL MECHANICAL SPRING RETURN 12-1 TECHNOLOGY DRIVE, APPROVAL ALL EQUIPMENT REMOVED SHALL BE DISPOSED OF BY THE SUBCONTRACTOR. STAINLESS STEEL CLAMPS. MECHANISM SHALL BE BUILT INTO THE ACTUATOR HOUSING. NON—MECHANICAL FORMS OF SETAUKET, NY 11733 5. INSULATION 1.5. GUARANTEE 2.7. SUPPORT HORIZONTAL DUCTS WITH HANGERS SECURED TO STRUCTURAL STEEL ABOVE AT FAIL—SAFE OPERATION ARE NOT ACCEPTABLE. \ P. 631.689.8450 1.5.1. ALL WORK SHALL BE GUARANTEED AGAINST DEFECTS FOR A PERIOD OF ONE YEAR FROM INTERVALS NOT EXCEEDING 8'-0". INSTALL ADDITIONAL STEEL AS REQUIRED. 5.1. ALL PIPING, DUCTWORK AND EQUIPMENT THAT TRANSMITS OR RECEIVES HEAT, WILL FORM F. 636 9 DATE OF FINAL ACCEPTANCE OF THE INSTALLATION AND ANY PORTIONS OF THE WORK CONDENSATION OR IS SUBJECT TO FREEZING, SHALL BE INSULATED UNLESS IT IS 9.4. ALL SPRING RETURN ACTUATORS SHALL BE CAPABLE OF BOTH CLOCKWISE OR \\ www.wfcaia.coia.com WHICH DEVELOP DEFECTS DURING THAT TIME SHALL BE REPLACED OR REPAIRED IN A 2.8. ALL SQUARE ELBOWS SHALL BE PROVIDED WITH SINGLE TURNING VANES ON SIDE RAILS, A SPECIFICALLY STATED OTHERWISE. INSULATION SHALL CONFORM TO THE RECOMMENDATIONS COUNTER—CLOCKWISE SPRING RETURN OPERATION BY SIMPLY CHANGING THE MOUNTING MANNER SATISFACTORY TO THE TENANT OR OWNER. MAXIMUM OF 4 INCHES ON CENTER. OF THE NFPA, & SHALL HAVE COMPOSITE FIRE & SMOKE HAZARD RATINGS AS TESTED BY ORIENTATION. I T E C T S AND PROVIDE A 2 TO 10 VDC OR 4 TO 20 mA OPERATING RANGE.1.5.2. ALL COMPRESSORS SHALL BE GUARANTEED AGAINST DEFECTS FOR A PERIOD OF FIVE PROCEDURE ASTM—E84, NFPA 255 OR UL 723, NOT EXCEEDING: FLAME SPREAD 25, SMOKE YEARS FROM DATE Of FINAL ACCEPTANCE OF THE INSTALLATION. ANY DEFECTS OF THE 2.9. REGISTERS, GRILLES AND CEILING OUTLETS DEVELOPED 50. 9.5. PROPORTIONAL ACTUATORS SHALL ACCEPT A 0 TO 10 OR 0 . mA CONTROL INPUT COMPRESSOR WHICH DEVELOP DURING THAT TIME SHALL BE REPLACED OR REPAIRED IN 2.9.1. ALL EXISTING AIR OUTLETS WHICH ARE EXISTING TO STAY OR TO BE REUSED SHALL BE ALL L ACTUATORS SHALL NO. DATE SUBMISSION A MANNER SATISFACTORY TO THE TENANT OR OWNER. CLEANED. 5.2. PIPE & FITTING INSULATION PROVIDE A 2 TO 10 VDC POSITION FEEDBACK SIGNAL. 2.9.2. FURNISH AND INSTALL ALL METAL DIFFUSERS, GRILLES AND REGISTERS AS INDICATED ON 5.2.1. REFRIGERANT PIPING: 1 10/10/17 ISSUED FOR BID 9.6. ALL 24 VAC/VDC ACTUATORS SHALL OPERATE ON CLASS 2 WIRING AND SHALL NOT REQUIRE 1.6. PERMITS AND CERTIFICATES THE CONTRACT DRAWINGS. ALL SIZES, AIR DISTRIBUTION PATTERNS AND AIR VOLUME 5.2.1.1. SUCTION: FIBERGLASS WITH ALL SERVICE JACKET. 2 11/02/17 ISSUED FOR FILING 1.6.1. GIVE NECESSARY NOTICES, FILE DRAWINGS AND SPECIFICATIONS WITH THE DEPARTMENTS CAPACITIES SHALL BE AS SPECIFIED ON THE CONTRACT DRAWINGS. 5.2.1.2. HOT GAS: FIBERGLASS W ALL SERVICE JACKET ON LINE EXPOSED TO OUTDOORS MORE THAN 10 VA FOR AC OR MORE THAN 8 WATTS FOR DC APPLICATIONS. ACTUATORS HAVING JURISDICTION, OBTAIN PERMITS OR LICENSES NECESSARY TO PERFORM THIS 2.9.3. ALL DIFFUSERS AND REGISTERS SHALL BE PRIME COATED STEEL WITH BAKED WHITE WHEN CONDENSER IS TO OPERATE AT LOW AMBIENT CONDITIONS. OPERATING ON 120 VAC POWER SHALL NOT REQUIRE MORE THAN 10 VA. ACTUATORS WORK, AND PAY ALL FEES THEREFORE. ENAMEL FINISH, UNLESS OTHERWISE NOTED, 5.2.2. GLYCOL PIPING: OPERATING ON 230 VAC POWER SHALL NOT REQUIRE MORE THAN 11VA. 1.6.2. ARRANGE FOR INSPECTIONS AND TESTS OF ANY OR ALL PARTS OF THE WORK AS 2.9.4. ALL CEILING TYPE AIR DIFFUSERS SHALL BE PROVIDED WITH AIR EQUALIZING DEFLECTORS, 5.2.2.1. WITHIN BUILDING: FIBERGLASS W/ALL SERVICE JACKET. 9.7. ALL NON—SPRING RETURN ACTUATORS SHALL HAVE AN EXTERNAL MANUAL GEAR RELEASE TO REQUIRED BY AUTHORITIES OR UTILITY COMPANIES HAVING JURISDICTION AND PAY ALL FULLY ADJUSTABLE FOR HORIZONTAL TO VERTICAL AIR FLOW. 5.2.2.2. OUTSIDE BUILDING: NO INSULATION REQUIRED. FEES OR CHARGES FOR SAME. 2.9.5. ALL SUPPLY OUTLETS TO BE COVERED INITIALLY WITH TWO LAYERS OF FINE MESH 5.2.3. HOT & COLD WATER PIPING: ELASTOMERIC INSULATION. ALLOW MANUAL POSITIONING OF THE DAMPER WHEN THE ACTUATOR IS NOT POWERED. SPRING RETURN ACTUATORS WITH MORE THAN 60 IN.—LB. TORQUE CAPACITY SHALL HAVE A CHEESE CLOTH TO TRAP FOREIGN DEBRIS UPON SYSTEM START—UP. ONCE SYSTEM HAS 5.2.4. CONDENSATE DRAIN PIPING (IN CEILING SPACES): FIBERGLASS W/ALL SERVICE JACKET MANUAL CRANK FOR THIS PURPOSE. 1.7. LAWS AND ORDINANCES RUN FOR 8 HOURS, CHEESE CLOTH TO BE REMOVED & FILTERS CHANGED, WHERE (ELASTOMERIC INSULATION OF COMPARABLE THERMAL CHARACTERISTICS ETC. MAY BE 1.7.1. INFORM THE TENANT OR OWNER OF ANY WORK OR MATERIALS WHICH VIOLATES ANY OF APPLICABLE. ANY SUBSEQUENT WORK TO THE DUCTWORK WILL WARRANT REPEATING THIS SUBMITTED FOR APPROVAL). 9.8. ALL MODULATING ACTUATORS SHALL HAVE AN EXTERNAL, BUILT—IN SWITCH TO ALLOW THE THE APPLICABLE LAWS AND REGULATIONS BEFORE PROCEEDING WITH THE WORK. STEP. 5.2.5. FITTING INSULATION: SAME TYPE AND THICKNESS AS ADJACENT PIPES (LESS JACKET) REVERSING OF DIRECTION OF ROTATION. 1.8. STANDARDS 2.10. FLEXIBLE DUCT CONNECTIONS WITH 'ZESTON' TYPE PRE—MOLDED PVC JACKETING. 9.9• ACTUATORS SHALL BE PROVIDED WITH A CONDUIT FITTING AND A MINIMUM THREE—FOOT 1.8.1. MATERIALS SPECIFIED BY REFERENCE TO A SPECIFIC STANDARD SUCH AS THE AMERICAN 2.10.1. PROVIDE FLEXIBLE CONNECTIONS, WHEREVER DUCTWORK CONNECTS TO VIBRATION 5.2.6. FOR INSULATION THICKNESS, REFER TO TABLE ON SCHEDULES SHEET. ELECTRICAL CABLE & SHALL BE PRE—WIRED TO ELIMINATE THE NECESSITY OF OPENING THE SOCIETY OF TESTING MATERIALS, UNDERWRITERS' LABORATORIES, AMERICAN NATIONAL ISOLATED EQUIPMENT, OF NEOPRENE COATED FLAMEPROOF FABRIC CRIMPED INTO DUCT ACTUATOR HOUSING TO MAKE ELECTRICAL CONNECTIONS. STANDARDS INSTITUTE, FEDERAL SPECIFICATIONS, A TRADE ASSOCIATION STANDARD, OR FLANGES FOR ATTACHMENT INTO DUCT AND EQUIPMENT. MAKE JOINT AIRTIGHT. PROVIDE 5.3. APPLY ALL INSULATION TO PIPING, EQUIPMENT, FITTINGS, ETC. IN STRICT ACCORDANCE WITH OTHER SIMILAR STANDARD SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST SUFFICIENT FLEXIBILITY TO ACCOMMODATE ALL REASONABLE MOVEMENT. THE MANUFACTURER'S RECOMMENDATIONS. ALL JOINTS SHALL BE SEALED WITH ADHESIVE TO 9.10. ACTUATORS SHALL BE UNDERWRITERS LABORATORIES STANDARD 873 LISTED AS MEETING KEY PLAN: REVISION THEREOF IN EFFECT AT THE TIME OF BIDDING, EXCEPT AS LIMITED BY TYPE, PROVIDE A CONTINUOUS VAPOR BARRIER JACKET. OUTDOOR PIPING REQUIRING INSULATION CLASS OR GRADE, OIR MODIFIED IN SUCH REFERENCE. 2.11. FIRE DAMPERS SHALL HAVE "OUTDOOR" JACKETING OR PROTECTIVE COATINGS AS RECOMMENDED BY CORRECT SAFETY REQUIREMENTS AND RECOGNIZED INDUSTRY STANDARDS. 1.8.2. ALL MATERIALS, EQUIPMENT AND APPARATUS SHALL BE ELECTRICAL TESTING 2.11.1. PROVIDE FIRE OR FIRE/SMOKE DAMPERS WHERE INDICATED ON DRAWINGS. DAMPERS MANUFACTURER. 9.11. ACTUATORS SHALL BE DESIGNED FOR A MINIMUM OF 60,000 FULL STROKE CYCLES AT THE µ "' LABORATORIES OR UNDERWRITERS' LABORATORIES LISTED OR LABELED FOR ALL ITEMS SHALL BE U.L. LISTED. FIRE DAMPERS SHALL BE OF THE CURTAIN—TYPE WITH BLADES ACTUATOR'S RATED TORQUE AND SHALL HAVE A 2—YEAR MANUFACTURER'S WARRANTY, WHERE SUCH LISTING OR LABELING IS AVAILABLE. ITEMS WHICH ARE NOT LISTED OR OUT OF THE AIRSTREAM. 5.4. DUCTWORK AND CASINGS STATING FROM THE DATE OF INSTALLATION. MANUFACTURER SHALL BE IS09001 CERTIFIED. LABELED WILL NOT BE ACCEPTED IF LISTED OR LABELED EQUIPMENT CAN BE OBTAINED 2.11.2. PROVIDE ACCESS DOORS LARGE ENOUGH (16"X16" MIN.) TO PERMIT MAINTENANCE AND 5.4.1. RETURN AIR DUCTS DO NOT HAVE TO BE INSULATED WHERE RUN IN AIR CONDITIONED ACTUATORS SHALL BE AS MANUFACTURED BY BELIMO, TRANE, ANDOVER OR APPROVED FROM ANOTHER ACCEPTABLE MANUFACTURER. EACH COMPONENT OF ASSEMBLIES SHALL RESETTING OF DEVICES. WHERE APPLICABLE PLACE ACCESS DOORS ON THE LATCH AREAS AND IN HUNG CEILING WITH PLENUM RETURN. DUCTED RETURNS IN PLENUMS EQUAL. BE LISTED BY THE LABORATORIES AS A "RECOGNIZED COMPONENT." COMPONENTS NOT RELEASE AND LINK SIDE OF THE FIRE DAMPER. MUST BE INSULATED. SO LISTED OR MARKED WILL NOT BE ACCEPTED IF LISTED OR MARKED COMPONENTS ARE 5.4.2. SUPPLY DUCTS MUST BE INSULATED THROUGHOUT, UNLESS NOTED OTHERWISE. 9.12. AMOUNT OF ACTUATORS TO BE COORDINATED IN FIELD. AVAILABLE FROM ANOTHER MANUFACTURER. ALL EQUIPMENT MUST HAVE MEA APPROVAL. 2.12. AUTOMATIC CONTROL DAMPERS 5.4.3. FRESH AIR INTAKES (INCLUDING DUCTWORK FOR AIR COOLED CONDENSERS) AND RETURN 2.12.1. AUTOMATIC DAMPERS SHALL BE OF GALVANIZED STEEL CONSTRUCTION. DUCTS, WHERE EXPOSED: 1-1/2", 6# DENSITY RIGID BOARD WITH VAPOR SEAL/ALL 1.9. CUTTING, ALTERING AND PATCHING 2.12.2. BLADES SHALL BE OF THE TRIPLE GROOVE OR DOUBLE SKIN AIRFOIL TYPE. BLADE EDGE SERVICE JACKET, R-6 MINIMUM. 1.9.1. THE SUBCONTRACTOR SHALL DO ALL CUTTING, CORE DRILLING, ALTERING AND PATCHING SEALS SHALL BE OF EXTRUDED VINYL, SILICONE OR INFLATABLE PVC COATED POLYESTER. 5.4.4. CONDITIONED SUPPLY AIR & RETURN DUCTS, WHERE EXPOSED: 1-1/2", 6# DENSITY AS REQUIRED FOR THE INSTALLATION OF HIS/HER WORK (UNLESS DIRECTED OTHERWISE 2.12.3. BEARINGS SHALL BE STAINLESS STEEL OR SYNTHETICALLY MOLDED. AXLES SHALL BE RIGID BOARD WITH VAPOR SEAL/ALL SERVICE JACKET, R-6 MINIMUM. BASED ON OWENS BY G.C.). INCLUDING THE RESTORING OF EXISTING WORK THAT IS DAMAGED AND/OR STEEL HEXAGONALLY SHAPED. CORNING SERIES 705 DUCT INSULATION. ALTERED DUE TO REMOVAL WORK. ALL MATERIALS AND WORKMANSHIP REQUIRED IN 5.4.5. CONDITIONED SUPPLY AIR & RETURN DUCTS, WHERE CONCEALED: 1-1/2" FLEX. CONNECTION WITH CUTTING, ALTERING AND PATCHING SHALL MATCH THE EXISTING WORK 2.13. ACCESS DOORS FIBERGLASS BLANKET W/VAPOR SEAL/ALL SERVICE JACKET, R-6 MINIMUM. mac\ IN EVERY RESPECT. 2.13.1. PROVIDE PRE—MANUFACTURED 22/24 GA. GALV. STEEL ACCESS DOORS WITH CONTINUOUS 1.9.2. PROVIDE AND PLACE REQUIRED SLEEVES, FORMS AND INSERTS BEFORE WALL OR PIANO—TYPE HINGE & GASKET. SIZE SHALL BE AS INDICATED ON DRAWINGS. MINIMUM 6. PAINTING AREA OF WORK PARTITIONS ARE BUILT. SIZE WHEN NOT INDICATED SHALL BE 16"X16". ALL DOORS SHALL HAVE 1" THICK r�4 114 1.9.3. WHEN IT BECOMES NECESSARY TO CUT FINISHED MATERIALS, SUBMIT TO THE ENGINEER, FIBERGLASS INSULATION. 16" & UNDER SHALL SHALL HAVE 1 CAM LOCK, OVER 16" 6.1. INCLUDE THE PRIME PAINTING OF THE EXTERIOR SURFACES OF ALL EQUIPMENT AND DRAWINGS SHOWING THE WORK REQ'D AND OBTAIN COMMENTS BEFORE DOING SUCH SHALL HAVE 2 LOCKS. MATERIALS FURNISHED UNDER THIS SECTION, UNLESS SPECIFICALLY STATED OTHERWISE. CUTTING. GALVANIZED IRON, STAINLESS STEEL, COPPER, BRASS AND ALUMINUM MATERIALS REQUIRE NO 1.9.4. WHEREVER PIPES, CONDUITS, DUCTS, ETC. PASS THROUGH FINISHED WALLS (OR WHERE 2.14. FILTERS PRIME COAT. REQUIRED BY THE BUILDING CODE) THE CONTRACTOR SHALL SUPPLY METAL ESCUTCHEON 2.14.1. AT THE COMPLETION OF THE JOB AND PRIOR TO THE ACCEPTANCE MEETING, ALL PLATES ON BOTH SIDES OF THE WALL. FILTERS, TEMPORARY OR OTHERWISE, SHALL BE CHANGED OUT WITH NEW FILTERS OF 6.2. IRON WORK EXPOSED TO VIEW WITHIN THE BUILDING SUCH AS PIPE HANGERS, ANGLE 1.9.5. ALL UNUSED PIPING, DUCTWORK, HANGERS, AND SUPPORTS SHALL BE COMPLETELY THE SIZE, TYPE AND EFFICIENCY STATED ON THE CONTRACT DRAWINGS. SUPPORTS, BLACK IRON PARTITIONS, TANKS, ETC., SHALL BE PAINTED ONE PRIME COAT OF REMOVED AS SHOWN ON THE DRAWINGS, OR ALL THE WAY BACK TO THE CORE RISER 2.15. PANS ZINC CHROMATE. ALL CONCEALED IRON WORK SHALL INCLUDE A FACTORY COAT OF PAINT. CLOSET, OR BACK TO THE NEAREST ACTIVE BRANCH MAIN AND CAPPED, SEALED 2.15.1. 4" TALL SS DRIP PAN WITH WELDED SEAMS. CAULKED JOINTS AND/OR MATED FLAT UVI WATERTIGHT, OR AIRTIGHT. ALL THE OPENINGS RESULTING SHALL BE PROPERLY PANEL SECTIONS ARE NOT ACCEPTABLE. EXTENDED 6" BEYOND FOOTPRINT OF UNIT. 6.3. THE INSIDE OF ALL DUCTWORK WHERE VISIBLE THROUGH REGISTER FACES SHALL BE GIVEN PATCHED, SEALED AND FIRE—STOPPED TO MAINTAIN THE ORIGINAI INTEGRITY OF THE ROUNDED—OVER TOP EDGE SO THAT NO SHARP EDGES EXIST. ONE COAT OF DULL BLACK. PARTITION'S FIRE RATING. 3. TESTING. ADJUSTING & BALANCING (T.A.B.) 7. AUTOMATIC CONTROLS 1.10. RELATIONS WITH OTHER TRADES 1.10.1. COORDINATE WORK WITH ALL OTHER TRADES. CONFER WITH ALL OTHER CONTRACTORS 3.1. ALL BALANCING WORK SHALL BE PERFORMED BY AN INDEPENDENT CONTRACTOR WHO IS A 7.1. THE WORK SHALL INCLUDE THE FURNISHING AND INSTALLATION OF A COMPLETE SYSTEM OF WHOSWORKEWORK MIGHT AND EQUIPMENT NECPROPIER INSTALLATION,RELAT ONTO THEE WORKGE ALL PARTS AND EQUIPMENT OFHIS OTHERS, NATIONALLY RECBER IN OGNIZED ZA DDING OF EITHER BODY. BALANCING ASSOCIATED NOTAIR BEGIN NCE U TILCOUNCIL SOYSTOMHER COMA ATIBLE.TEMPERATURE LOCAL CONTROLLER SHALLCONTROL OF THESYSTEM ELE ELECTRIC/ELECTRONIC TRO EM SHALL N C ,DDCNTYPE. A/C REPLACEMENT WITH THE BUILDING CONSTRUCTION AND WITH ARCHITECTURAL FINISH SO THAT IT WILL INSTALLATION IS COMPLETE AND FULLY OPERATIONAL. PROVIDE VIEWPORT FOR USER INTERACTION. FOR CARRIER SWRM HARMONIZE IN SERVICE AND APPEARANCE. 3.2. THE SUBCONTRACTOR SHALL TEST, ADJUST AND BALANCE AIR MOVING AND WATER EQUIPMENT 7.2. THE CONTROL DESCRIPTION/SEQUENCE & AIRFLOW DIAGRAM, AS SHOWN ON THE DRAWINGS 1.11. DAMAGE TO PROPERTY AND DISTRIBUTION SYSTEMS TO THE QUANTITIES INDICATED ON THE DRAWINGS AND SUBMIT A IS (CHIEFLY FOR DESCRIBING DESIGN INTENT AND IS NOT NECESSARILY COMPLETE IN ALL 1.11.1. RESTORE TO ITS ORIGINAL CONDITION, WITHOUT EXTRA PAYMENT, ANY OF THE OWNER'S CERTIFIED REPORT INCLUDING: RECORDED RPMs, GPMs, CFMs, SUPPLY & RETURN RESPECTS. PROPERTY THAT BECOMES DAMAGED DUE TO THE NEGLIGENCE OF EMPLOYEES OR TEMPERATURES AND STATIC PRESSURES AND FAN, MOTOR AND AIR OUTLET DATA. 31755 MAIN RD. AGENTS OF THE CONTRACTORS. SUCH REPAIRS SHALL BE ACCEPTABLE TO THE OWNER. 7.3. EACH CONTROL SYSTEM SHALL BE COMPLETE WITH ALL NECESSARY SENSORS, THERMOSTATS, 3.3. T.A.B. WORK SHALL INCLUDE ANY CHANGES TO PULLEYS, BELTS AND/OR THE ADDITION OF VALVES, RELAYS, SWITCHES, ACTUATORS, ACCESSORIES, ETC. INTERCONNECTED & ARRANGED CUTCHOGUE, W 1.12. SHUTDOWNS ANY DAMPERS/BALANCING VALVES NECESSARY FOR CORRECT BALANCE AT NO ADDITIONAL IN INTENDED SEQUENCE TO MAINTAIN DESIRED CONDITIONS & FUNCTIONS. GROUND FLOOR 1.12.1. REQUEST FOR SHUTDOWNS MUST BE DELIVERED TO THE MANAGER OF BUILDING COST TO OWNER. OPERATIONS AT LEAST SEVEN (7) WORKING DAYS PRIOR TO THE REQUESTED SHUTDOWN 7.4. LOCATION OF INSTRUMENTS, PANEL BOARDS ETC. SHALL BE SHOWN ON SUBMITTALS OR BE TITLE: AND SHALL BE SUBJECT TO THE FINAL APPROVAL OF THE BUILDING MANAGER. 3.4. T.A.B. WORK SHALL NOT BE PERFORMED WITHOUT PRIOR NOTIFICATION OF ENGINEER & PLACED AS DIRECTED BY THE ARCHITECT/ENGINEER. ALL PANELS & INSTRUMENTS SHALL OWNER'S REPRESENTATIVE ONE OF WHICH SHALL BE PRESENT. WORK PERFORMED WITHOUT HAWE LAMACOID NAMEPLATES STATING USE & SYSTEM SERVED. 1.13. SHOP DRAWINGS DESIGNATED REPRESENTATIVE PRESENT MAY, AT THE ENGINEER'S DISCRETION, BE REQUIRED SPECIFICATIONS 1.13.1. SUBMIT SHOP DRAWINGS OF ALL REQUIRED EQUIPMENT, AS WELL AS AIR DEVICES, TO BE RE—PERFORMED. FIVE COPIES OF THE REPORT SHALL BE SUBMITTED TO THE 7.5. AUTOMATIC ACTUATORS SHALL BE OF THE ELECTRONIC, DIRECT COUPLED TYPE UON. DUCTWORK, PIPING, ACCESSORIES, HANGERS AND SUPPORTS, FILTERS, CONTROLS AND PROJECT ENGINEER. ACTUATORS REQUIRED TO HAVE FAIL—SAFE FEATURE SHALL DO SO BY MEANS OF A SPRING WIRING DIAGRAMS, DAMPERS, LOUVERS, BASEBOARD RADIATION AND REFRIG. PIPING. RE17URN MECHANISM BUILT INTO THE ACTUATOR HOUSING. ALL ACTUATORS SHALL HAVE A OBTAIN WRITTEN REVIEW COMMENTS BEFORE ORDERING OR INSTALLING ANY MATERIAL OR 4. PIPING & RELATED WORK MEANS OF MANUAL OVERRIDE & A BUILT—IN SWITCH TO ALLOW REVERSING OF DIRECTION. DATE: 8/16/17 COMPONENTS. A MINIMUM OF 7 COPIES OF ALL SHOP DRAWINGS ARE TO BE SUBMITTED ACTUATORS SHALL MEET U.L. STANDARD 873. ACTUATORS SHALL HAVE MIN. 2 YEAR WITH ONE COPY RETURNED TO THE CONTRACTOR. 4.1. EXCEPT AS OTHERWISE NOTED, ALL HVAC PIPING SHALL BE STANDARD WEIGHT STEEL PIPE WARRANTY. PROJECT NO: 17-2165 WITH 150 PSIG CAST IRON SCREWED FITTINGS AND FLANGES THROUGH 2-1/2" AND BUTT DRAWN BY: EAB 1.14. AS—BUILT DRAWINGS �� 7.6. THE WORK SHALL INCLUDE STARTUP, SYSTEM VERIFICATION AND DEBUGGING. CONTROLS 1.14.1. FURNISH "AS—BUILT" DRAWINGS AS PART OF THE WORK OF THIS SECTION, CONSISTING WELDED FITTINGS AND WELDING NECK FLANGES FOR 3 AND ABOVE. CONTRACTOR SHALL PROVIDE AN 8—HOUR ORIENTATION FOR OWNER'S MAINTENANCE CHECKED BY: KJH / PEJ OF A COMPLETE SET OF MYLAR/SEPIA TRANSPARENCIES AND TWO BLUE LINE COPIES. PERSONNEL. CONTRACTOR SHALL PROVIDE A ONE YEAR WARRANTY ON SYSTEM COMPONENTS SCALE: NONE DRAWING NO: 1 SPECIFICATIONS M = 6040"1000 SCALE NONE SHEET NO: 9 OF 9 ELECTRICAL LEGEND ELECTRICAL GENERAL NOTES ELECTRICAL ABBREVIATIONS 1. ALL ELECTRICAL WORK SHALL COMPLY WITH THE MOST RECENT EDITIONS OF THE A AMPERES FACP FIRE ALARM CONTROL PANEL MTD MOUNTED VERIZON NATIONAL STANDARDS, THE RULES OF THE NATIONAL ELECTRICAL CODE, THE 1.) ALL EQUIPMENT/DEVICES ARE NEW UNLESS OTHERWISE NOTED. ELECTRICAL CODE OF THE CITY OF NEW YORK (WHEN APPLICABLE), ELECTRICAL AC AIR CONDITIONING UNIT FBO FURNISHED BY OTHERS MTG MOUNTING UTILITY REQUIREMENTS AND ANY APPLICABLE LOCAL CODES. 2.) E- ADJACENT TO DEVICES DENOTES EXISTING TO REMAIN. ACC AIR COOLED CONDENSING UNIT FDR FEEDER N NEUTRAL 2. THE MINIMUM SIZE WIRE SHALL BE #12 COPPER AND ALL WIRE SHALL BE H 3.) R- ADJACENT TO DEVICES DENOTES EXISTING TO BE RELOCATED. ENCLOSED IN CONDUIT WITH A MINIMUM SIZE OF 3/4". AHU AIR HANDLING UNIT FIN FL FINISHED FLOOR NC NORMALLY CLOSE 4.) D- ADJACENT TO DEVICES DENOTES EXISTING TO BE DEMOLISHED. 3. ALL EXISTING LIGHTING NOT SHOWN IS TO REMAIN. MAINTAIN CONTINUITY OF ALL AFF ABOVE FINISHED FLOOR FIXT FIXTURE NIC NOT IN CONTRACT REMAINING LIGHTING CIRCUITS WHERE AFFECTED BY THESE ALTERATIONS. AIC AMPERE INTERRUPTING CAPACITY FL FLOOR NO NORMALLY OPEN Jacobsen & Horan 5.) N/L- ADJACENT TO LIGHT FIXTURE DENOTES NIGHT LIGHT. FIXTURE UNSWITCHED. 4. PROVIDE LAMPS FOR ALL NEW LIGHT FIXTURES. ALL T8 LAMPS SHALL HAVE 3500'K ARF ABOVE RAISED FLOOR FLA FULL LOAD AMPERES NTS NOT TO SCALE COLOR. AWG AMERICAN WIRE GAUGE FLUOR FLUORESCENT OC ON CENTER Engineering, P.C. 5. PROVIDE UPDATED TYPE-WRITTEN PANEL DIRECTORIES TO INDICATE NEW CIRCUITS. BHP BRAKE HORSEPOWER FMC FLEXIBLE METAL CONDUIT P POLE 990 South 2nd Street P1-2,4 HOMIE RUN TO PANEL P1, CIRCUITS 2 & 4 HASH MARKS FOR PANELBOARDS WITH NO DOOR AND/OR DIRECTORY FRAME PROVIDE PHENOLIC Ronkonkoma, NY 11779 #6 INDICATE NUMBER OF CONDUCTORS IF IN EXCESS OF TWO, NAMEPLATES ADJACENT TO BRANCH CIRCUIT BREAKER TO INDICATED NEW CIRCUITS. BLDG BUILDING G GROUND PB PULL BOX 0: (631) 580-6100 EXCLUDING GROUND #6 INDICATES WIRE SIZE, MIN. SIZE #12, IF NOT INDICATED. SIZE GROUND PER CODE. 6. WIRING FOR 48V DC FIXTURES SHALL BE SIZED FOR VOLTAGE DROP, #10 C CONDUIT GFI GROUND FAULT INTERRUPTING 0 PHASE F: (631) 580-6101 AWG MINIMUM. CAB CABINET HC HUNG CEILING PNL PANEL www.jhepc.com 0 7. THE GENERAL CONTRACTOR SHALL COORDINATE ALL WORK WITH TRADES,PANELBOARD- REFER TO SCHEDULE FOR DETAILS CB CIRCUIT BREAKER HH HANDHOLE PWR POWER CUT/PATCH/REPAIR ALL WALL, FLOOR AND CEILING PENETRATIONS AS IS A VIOLATION OF NEW YORK NEEDED, TO MATCH. CKT CIRCUIT HP HORSEPOWER RECEIPT RECEPTACLE ��OF NEw y R STATE EDUCATION LAW FOR ANY O JUNCTION BOX; SIZED PER CODEP JACO O PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED 8. ALL FIRE-RATED WALL PENETRATIONS MUST BE FIRE STOPPED, INCLUDING ANY CLG CEILING HR HOUR RLA RATED LOAD AMPERES 6� '� PROFESSIONAL ENGINEER, TO PIPING, CONDUIT, CABLE TRAYS, SUPERSTRUCTURE, ETC. * (n ALTER W ITEM ON THIS DRAWING CLOS CLOSET HT HEIGHT RM ROOM r IN ANY WAY. IF AN ITEM IS WIRING IN CONDUIT ALTERED, THE ALTERING ENGINEER Uri SHALL AFFIX TO THE ITEM 9. PROVIDE ALL REQUIRED PULL BOXES AND MISCELLANEOUS HARDWARE FOR COMM COMMUNICATION HZ HERTZ SD SMOKE DETECTOR y �1!;, HIS/HER SEAL AND THE NOTATION ALL CONDUIT RUNS. ALL CONDUITS SHALL BE PROPERLY SUPPORTED. s :.` d 2 ALTERED BY" FOLLOWED BY ^ CONDUIT TURNED UP �O 0�646`y � HIS/HER SIGNATURE AND THE CONT CONTINUATION INCAND INCANDESCENT SPEC SPECIFICATION ,o � DATE OF SUCH ALTERATION AND A 0 CONDUIT TURNED DOWN 10. ALL EQUIPMENT IS NEW UNLESS OTHERWISE NOTED. CORR CORRIDOR J JUNCTION BOX SPKLR SPRINKLER 90FFSSIONP, SPECIFIC DESCRIPTION OF THE ALTERATION. 11. THE ELECTRICAL CONTRACTOR SHALL "TEST OUT" PANELS DESIGNATED FOR USE CT CURRENT TRANSFORMER JB JUNCTION BOX SS STAINLESS STEEL CONSULTANT: AND VERIFY POWER AVAILABILITY FROM THESE PANELS. IF POWER IS NOT SINGLE POLE SWITCH AVAILABLE, THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER CU COPPER KCMIL THOUSAND CIRCULAR MILS SW SWITCH ;. ,. I,:. 12-1 TECHNOLOGY DRIVE, OF THE CLOSEST PANEL WHICH IS AVAILABLE AND HAS THE NECESSARY POWER. SETAUKET, NY 11733 DG DIESEL GENERATOR KVA KILOVOLT AMPERE SWGR SWITCHGEAR P. 631.689.8450 2 DOUBLE POLE SWITCH 12. BALANCE PANELBOARD LOADS EQUALLY OVER THREE (3) PHASES. DISC DISCONNECT KW KILOWATT TEL TELEPHONES F. 631.689.8459 www.wfcaia.com 13. UNLESS NOTED OTHERWISE, ALL EQUIPMENT INSTALLED INDOORS SHALL HAVE NEMA 1 DN DOWN KWH KILOWATT HOUR \\ \ 3 THREE WAY SWITCH ENCLOSURES AND ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE NEMA 3R TRANS TRANSFORMER ENCLOSURES. DWG DRAWING LF LINEAR FEET TYP TYPICAL I T E C T S P "P" INDICATES SWITCH WITH PILOT LIGHT 14. ALL EQUIPMENT INSTALLED OUTDOORS SHALL BE SUPPORTED USING GALVANIZED EC ELECTRICAL CONTRACTOR LFMC LIQUID-TIGHT FLEXIBLE METAL CONDUIT UH UNIT HEATER STEEL STRUT WITH STAINLESS STEEL HARDWARENO. DATE SUBMISSION SINGLE RECEPTACLE- 120V, 20A, NEMA 5-20R, "WP ." INDICATES EL ELEVATION LRA LOCKED ROTOR AMPERES UON UNLESS OTHERWISE NOTED 1 10/10/17 ISSUED FOR BID WEATHERPROOF 15. UNLESS NOTED OTHERWISE, ALL CONDUIT RUN WITHIN OR THROUGH DC POWER ELECT ELECTRICAL LTG LIGHTING UPS UNINTERRUPTIBLE POWER SUPPLY 2 11/02/17 ISSUED FOR FILING ROOMS SHALL BE RIGID ALUMINUM. (f11 DUPLEX CONVENIENCE RECEPTACLE- 120V, 20A, NEMA 5-20R, ELEV ELEVATOR MAX MAXIMUM V VOLT OR VOLTAGE "WP" INDICATES WEATHERPROOF 16. PROVIDE FLEXIBLE CONDUIT CONNECTION AT ALL EQUIPMENT SUBJECT TO VIBRATION. EMERG EMERGENCY MCB MAIN CIRCUIT BREAKER W WATT DUPLEX GROUND FAULT INTERRUPTING (GFI) RECEPTACLE- 17. ALL PANELBOARDS AND ELECTRICAL DISTRIBUTION EQUIPMENT FURNISHED OR EMT ELECTRICAL METALLIC TUBING MCC MOTOR CONTROL CENTER W 120V, 20A, NEMA 5-20R, "WP" INDICATES WEATHERPROOF UTILIZED UNDER THIS PROJECT SHALL BE PROVIDED WITH PHENOLIC NAMEPLATES / WITH INDICATING THE PANEL NAME AND WHERE IT IS FED FROM. EP ELECTRICAL PANEL MER MECHANICAL EQUIPMENT ROOM W/0 WITHOUT DOUBLE DUPLEX RECEPTACLE- 120V, 20A, NEMA 5-20R 18. THE TERMS "PROVIDE" AND "FURNISH AND INSTALL" SHALL BE USED EQ EQUAL MFS MAIN FUSED SWITCH WP WEATHERPROOF 2 (QUAD) INTERCHANGEABLY TO INDICATE THAT THE CONTRACTOR SHALL FURNISH AND INSTALL DEVICE/ITEM. EQPT EQUIPMENT MH MANHOLE XP EXPLOSION PROOF 4 SPECIAL PURPOSE RECEPTACLE- REFER TO DRAWINGS 19. THE ELECTRICAL LEGEND, ELECTRICAL GENERAL NOTES, GROUNDING GENERAL NOTES EXIST EXISTING MIN MINIMUM AND ELECTRICAL SPECIFICATIONS ARE SHOWN IN GENERIC TERMS. ALL SCOPE OF FA FIRE ALARM MLO MAIN LUGS ONLY WORK, SPECIFICATIONS AND INFORMATION INDICATED ON PLAN, SCHEDULES OR HEAVY DUTY UNFUSED DISCONNECT SWITCH DETAILS SHALL OVERRIDE ANY SCOPE OF WORK, SPECIFICATIONS OR INFORMATION FAAP FIRE ALARM ANNUNCIATOR PANEL MOT MOTOR �60 60 INDICATES AMPERE RATING, INDICATED WITHIN THE ELECTRICAL LEGEND, ELECTRICAL GENERAL NOTES, GROUNDING KEY PLAN: 3 POLE UNLESS NOTED OTHERWISE GENERAL NOTES OR ELECTRICAL SPECIFICATIONS. 20. THE CONTRACTOR SHALL PROVIDE A CERTIFICATE OF ELECTRICAL INSPECTION FOR HEAVY DUTY FUSED DISCONNECT SWITCH THE WORK FROM THE LOCAL ELECTRICAL INSPECTION AGENCY AND PAY ALL ;? ` 60/40 60/40 INDICATES 60A SWITCH, 40A FUSES, ASSOCIATED FEES. 3 POLE UNLESS NOTED OTHERWISE it 21. THE TERM "EXTEND EXISTING WIRING/CONDUIT" SHALL INCLUDE CUTTING BACK, ® MAGNETIC MOTOR STARTER SIZED AS REQUIRED. NEMA SIZE 1 EXTENDINGAND RE-ROUTING EXISTING WIRING/CONDUIT TO NEW LOCATIONS) AS MINIMUM REQUIRED. SHOP DRA00 WINGS PANEL DIRECTORIES COMBINATION MAGNETIC MOTOR STARTER AND DISCONNECT 00 SIZEDAS REQUIRED. IN GENERAL, PREPARE/SUBMIT THE FOLLOWING SHOP DRAWING PROVIDE UPDATED TYPE-WRITTEN DIRECTORIES FOR THE I NEMA SIZE 1 MINIMUM SUBMITTALS FOR ENGINEER APPROVAL (ELECTRONIC PDF FORM FOLLOWING PANELS: _..i! , GROUNDING GENERAL NOTES MANUAL MOTOR STARTER WITH THERMAL OVERLOADS IS PREFERRED). CONTRACTOR SHALL INDICATE COMPLETE MDP (SECTION 1 & 2) T MODEL NUMBERS ON CATALOG CUT SHEETS: PP-PA MOTOR, NUMERAL INDICATES HORSEPOWER- G1. GROUND ALL ELECTRICAL WORK IN ACCORDANCE WITH THE MOST RECENT EDITIONS 0ELECTRICAL DISTRIBUTION EQUIPMENT (FUSIBLE SWITCH 0 PPAC SUPPLIED AND INSTALLED BY OTHERS AND OF VERIZON GROUNDING STANDARDS, THE NATIONAL ELECTRICAL CODE, ELECTRICAL UNITS, POWER PANELS, TRANSFORMERS, DISCONNECT a LP1A (LOCATED IN THE DC POWER ROOM) ABPA OF WORK WIRED BY THE ELECTRICAL CONTRACTOR UTILITY REQUIREMENTS AND THE ELECTRICAL CODE OF THE CITY OF NEW YORK SWITCHES, CIRCUIT BREAKERS, ETC.) 0 ANY PANEL WHERE REMOVED CIRCUITS ORIGINATE. ro (WHEN APPLICABLE). 0ELECTRICAL DEVICES (RECEPTACLES, WEATHERPROOF INDICATE THESE CIRCUITS AS SPARE. BOXES/COVERS, LIGHT SWITCHES. ETC.) • ANY PANEL WHERE ADDITIONAL CIRCUITS HAVE BEEN OS PENDANT MOUNTED OCCUPANC SENSOR (WATTSTOPPER DT-300) G2. ALL CENTRAL OFFICE GROUNDING SYSTEM GROUND CABLE SHALL BE 750KCMIL, LIGHT FIXTURES ADDED. STRANDED COPPER WITH TYPE RHH/LS LIMITED SMOKE, NON-HALOGENATED LIGHTING CONTROLS (OCCUPANCY SENSORS AND LIGHTING PROVIDE PLASTIC LAMACOID LABEL ADJACENT TO G.B. INSULATION AND GREEN COTTON BRAID JACKET IN ACCORDANCE WITH VERIZON CONTROL PANELS). UTILIZED DIRECTORY IRS UIT BREAKER PROVIDED.R SWITCH WHERE TYPED T.- COLILOCATOR GROUND BAR- LOCATE ABOVE CAGE DOOR GROUNDING STANDARDS. RACEWAYS/POWER POLES ' C.O.G.B. NTRAL OFFICE GROUND BAR G3. GROUNDING CONDUCTORS LARGER THAN #6 SHALL HAVE A MINIMUM BENDING TT- CE RADIUS OF 12". GROUNDING CONDUCTORS #6 AND SMALLER SHALL HAVE A V(3 r v 7&0 MINIMUM BENDING RADIUS OF 8". O.P.G.P OFFICE PRINCIPLE GROUND POINT T-F G4. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL GROUNDING INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. A.G.B. AUXIILIARY GROUND BAR (10" X 2" X 1/4") T_TG5. ALL GROUND CONNECTIONS SHALL BE TO CLEANED & BRIGHTENED METALLIC PANELBOARD/SWITCHBOARD NOTES A/C REPLACEMENT ❑M MOTORIZED DAMPER- SUPPLIED AND INSTALLED BY OTHERS SURFACE. UTILIZE STAR WASHERS AT GROUND CONNECTIONS. AND WIRED BY THE ELECTRICAL CONTRACTOR G6. ALL CONDUITS TO BE GROUNDED USING BONDING BUSHINGS AT EACH END. FOR CARRIER SWRM COORDINATE ALL WORK WITHIN EXISTING PANELS, INCLUDING ANY SHUTDOWNS WITH VERIZON FAC FIRE ALARM CONTROL PANEL POWER ENGINEERING AND REAL ESTATE PROPERTY MANAGEMENT. Fz_M_l FIRE ALARM ZONE MAP. 31755 MAIN RD. FSR POLARIZED SHUTDOWN RELAY. CUTCHOGUE, NY GROUND FLOOR O PHOTOELECTRIC SMOKE DETECTOR CORE DRILLING TITLE: OS c DUCT DETECTOR, "S" DENOTES SUPPLY LEGEND, ABBREVIATIONS & NOTES DS PRIOR TO ANY CORE DRILLING (WALLS OR SLABS), COORDINATE WITH THE GENERAL CONTRACTOR TO X-RAY THE WALL AND/OR SLAB TO VERIFY NO OBSTRUCTIONS DUCT DETECTOR, "R" DENOTES RETURN EXIST. DR DATE: 8/16/17 PROJECT NO: 17-2165 DRAWN BY: LAS CHECKED BY: KJH / PEJ SCALE: NONE DRAWING NO: THIS PLAN IS APPROVED ONLY FOR THE WORK INDICATED ON THE 0- APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO SHEET NO: 1 OF 5 BE RELIED UPON, OR TO BE CONSIDERED AS EITHER BEING APPROVED OR IN ACCORDANCE WITH APPLICABLE CODES. .. -.-..-- .�..._�........_.__...••.,�__...-___..._.__ ._.._-...._...-.... �..-... + TEMPORARY SPOT COOLING KEY NOTES _ .�--:::::,.__...•__.__--_...-_.._.-_�,:�.�::::::�.....-�-....�_._.._.... ._.._�...._..._.�_-__..�-._._..�.....�-...-... . � .P PC 4 1A 100-01 339— _ 01-01 — ....• j THE MECHANICAL CONTRACTOR SHALL INSTALL FOUR (4) 5—TON SPOT COOLERS TO PROVIDE TEMPORARY COOLING PRIOR I - TO ALL DEMOLITION WORK. 7 DC POWER ROOM I SPOT COOLER DESIGN IS BASED ON "OCEANAIRE MODEL PAC 6032", REQUIRING THREE PHASE, 208V AT 20.4 FULL � € L_J LOAD AMPS. APPROXIMATE UNIT LOCATIONS ARE SHOWN ON THE MECHANICAL PLANS. THE ELECTRICAL CONTRACTOR COMP/DEHY. RM SHALL INSPECT THE DELIVERED UNITS AND NOTIFY THE ENGINEER IMMEDIATELY IF THE UNIT NAMEPLATES DIFFER FROM THE ABOVE SPECIFICATIONS. EC SHALL FURNISH AND INSTALL L15-30R RECEPTACLES WITH BOX AND TEMPORARY WIRING } SIZED PER CODE FROM NEW PANEL PPAC. SEE KEY NOTES FOR DETAILS. AT THE END OF THE PROJECT AND AFTER -- -- COLL. SCOPE RM € VERIZON HAS ACCEPTED THE WORK, THE EC SHALL TURN OFF CB'S, REMOVE ALL TEMPORARY WIRING AND PROVIDE KO 11 . �, T �: I L=l SEALS IN PANEL. Jacobsen & Horan 21�R ..-.._.._-.�__..•.___... PCWERAF[:._ � Engineering, P.C. 990 South 2nd Street I , .: TEMPORARY SPOT COOLING KEY NOTES ❑X Ronkonkoma, NY 11779 !...-M PDC CC`���f € c O' (631) 580-6100 — ------ - - 1. DISCONNECT CONDUCTORS FROM EXISTING 3P 200A CB LOCATED IN DISTRIBUTION PANEL MDP SECTION 1 SERVING F: 631 580-6101 "• � � � � -� �--- THE AIR—COOLED CONDENSING UNIT ASSOCIATED WITH AIR HANDLER 245-01-02 STANDBY UNIT . UTILIZE )BREAKER ( ) FOR NEW PANEL. ( ) www.jhepc.com E € 2. FURNISH AND INSTALL 225A, 120/208V, 3 PHASE, 4 WIRE PANEL PPAC. WIRE 4-#3/0 + #6G IN 1-1/4" EMT WARNING: OF NFW IT IS A VIOLATION OF NEW YORK I .... FROM 3P/200A CB LOCATED IN DISTRIBUTION PANEL MDP (SECTION 1). REFER TO PANEL SCHEDULE FOR MORE �E y STATE EDUCATION LAW FOR ANY I INFORMATION. JACO O PERSON, UNLESS ACTING UNDER € Q 9.f THE DIRECTION OF A LICENSED POFESSIONAL ENG , TO I _ _ ALTER AN ITEM ONINEERTHIS DRAWING 3. PROVIDE TEMPORARY WIRING FROM FOUR (4) 3P/30A CB'S IN NEW PANEL PPAC TO TWO (2) SPOT COOLERS IN IN ANY WAY. IF AN ITEM IS THE CARRIER SWITCHROOM AND TWO (2) SPOT COOLERS IN THE 5ESS DIGITAL SWITCHROOM. Cc ALTERED, THE ALTERING ENGINEER _ _.... "ww W<:' (i I cu SHALL AFFIX TO THE ITEM HIS/HER SEAL AND THE NOTATION 4. PRIOR TO REMOVAL OF THE EXISTING HVAC UNITS, INSTALL NEW POWER ROOM EXHAUST FAN. REFER TO s� V� ALTERED BY" FOLLOWED BY ' 5ESS DIG. SW. € MDP (SECT. 2) I MECHANICAL EQUIPMENT CONNECTION SCHEDULE FOR CIRCUITRY INFORMATION. op 0�sas2 �� HIS/HER SIGNATURE AND THE DATE OF SUCH ALTERATION AND A 9CFESSION� SPECIFIC DESCRIPTION OF THE ALTERATION. ( 8 € i CONSULTANT: 12-1 TECHNOLOGY DRIVE, CT. 1) • Il�!1, (SE ..� � , .. . �; e SETAUKET, NY 11733 DEMOLITION KEY NOTES O „ P. 631.689.8450 F. 631.689.8459 I www.wfcaia.com j € 1. AFTER THE TEMPORARY SPOT COOLING IS IN PLACE, DEMOLISH CONTROL PANELS, MOTOR STARTERS, DISCONNECT . SWITCHES, CONDUIT/WIRE, ETC. ASSOCIATED WITH AIR HANDLERS, 245-01-01 & 245-01-02 IN THEIR ENTIRETY 61 I T E C T S - BACK TO THEIR SOURCES. A;,4, I EMG. ENGINE RM 2. DEMOLISH MOTOR STARTER, DISCONNECT SWITCH, CONDUIT/WIRE, ETC. ASSOCIATED WITH RETURN FAN, RAF-1, TO BE DEMOLISHED BACK TO DISTRIBUTION PANEL MDP (SECTION 2). NO. DATE SUBMISSION f ? E € 1 10/10/17 ISSUED FOR BID € - I --- — --- ---- ---- - - ---- -- 3. DEMOLISH CONDUIT/WIRE/CONTROLS, ETC. ASSOCIATED WITH UNIT HEATER TO BE DEMOLISHED BACK TO PANEL _ _..__ _ ___ �� - M ••_•••T PP—PA. 2 11/02/17 ISSUED FOR FILING BOILER RM 4. DEMOLISH MER LIGHTING, LIGHT SWITCHES AND ASSOCIATED CONDUIT/WIRE, ETC. BACK TO SOURCE. (TYP.) t 5. DEMOLISH JUNCTION BOX, TRANSFORMER, CONDUIT/WIRE, ETC. ASSOCIATED WITH MOTORIZED DAMPER TO BE --. \ DEMOLISHED BACK TO SOURCE. 6. DEMOLISH SUPPLY AND RETURN DUCT DETECTORS, FIRE SHUTDOWN RELAY AND ASSOCIATED CONDUIT/WIRE, ETC. 7 F—!, f BACK TO ASSOCIATED FACP. _ .._ L 1 10 • _••_ __ I �_... ___ _......- ::..... m ;:: :: __ —m € 7. DEMOLISH DISCONNECT SWITCHES, CONTROL PANELS, CONDUIT/WIRE, ETC. ASSOCIATED WITH HUMIDIFIERS BACK TO BACK TO DISTRIBUTION PANEL MDP (SECTION 2). 2 9 8. EXISTING DISTRIBUTION PANELS, MDP (SECTION 1 & 2), PANEL PP—PA AND PANEL LP1A TO REMAIN. MAINTAIN €€ CONTINUITY OF ALL EXISTING CIRCUITS TO REMAIN. PROTECT DURING CONSTRUCTION AS REQUIRED. KEY PLAN: r 6 ( 9. EXISTING CONTROL PANELS MOTOR STARTERS DISCONNECT SWITCHES PUMPS LIGHTING RECEPTACLES € .•.••_ w_••••_. CONDUIT/WIRE/CONTROLS, ETC. LOCATED IN THE BOILER ROOM TO REMAIN UNLESS OTHERWISE NOTED. MAINTAIN 5ESS TOLL STORERM _ :: ..w._ CONTINUITY OF EXISTING CIRCUITS. PROTECT DURING CONSTRUCTION. E€ 10. EXISTING DISCONNECT SWITCH — a FSR CONDUIT WIRE ETC. ASSOCIATED WITH ELECTRIC WATER HEATER TO REMAIN. MAINTAIN 5ESS MTCE. CTR. r,. - --1 € / • 11 PP PA 11 CONTINUITY OF EXISTING CIRCUIT. PROTECT DURING CONSTRUCTION. ' 1 S � € i I DS 11. EXISTING SWITCHES, MOTOR STARTERS, CONDUIT/WIRE, ETC. ASSOCIATED WITH AIR COMPRESSOR, OIL BURNER AND I J? E 7 WELL PUMP TO REMAIN. MAINTAIN CONTINUITY OF EXISTING CIRCUITS. PROTECT DURING CONSTRUCTION. 5 I 3 _- 1 L F-31 4 FZ2 I ---- , ..a .......�......__�......._..._....f�...�...-.....-...... _.._.....w..W SDR �U' � ----.._._..-._ I�--____-_.. _y� � � AREA of woxx iT wv I _ i .,. _.,.,_.....,....„.. .........•.......,.., RAF-1 4 tJ 1 li �. i i w CARRIER EQPT. TOLL ADMIN 245-01-02 1 245-01-017-T-] �JA(s I 'f € s 2 A PPAC _ , 131 ----- 7=77' i% A/C REPLACEMENT } ISI :: -_:. , : . ..:: . FOR CARRIER SWRM _ _ _ __ �_.. ...... ....- U'd— _..... 1-_ _ .W � ...�...._._ .._ ._ l-----_� CO STOR 1 LOCKER & LOUNGE , r` "� ,;��i, ; 31755 MAIN RD. f • � •_.__.�... _-_.. �=:::=11% '�.:. .--�/. _ CUTCHOGUE NY GROUND FLOOR TITLE: , LzM •••, GROUND FLOOR & ROOF TEMPORARY& DEMOLITION T COOLING NS t DEMOLITION KEY NOTES O - DATE: 8/16/17 I Jt1. DEMOLISH DISCONNECT SWITCHES, CONDUIT/WIRE, ETC. ASSOCIATED WITH AIR-COOLED PROJECT NO: 17-2165 CONDENSERS, ACC-1, ACC-2, ACC-3 AND ACC-4 BACK TO THEIR SOURCES. DRAWN BY: LAS UNISEX TL1r. MDF 2. DEMOLISH ROOF LIGHTING AND ASSOCIATED CONDUIT/WIRE, ETC. BACK TO THEIR SOURCES. CHECKED BY: KJH / PEJ ! r 3. EXISTING PITCH POCKET TO REMAIN AND BE RE-USED. SCALE: AS NOTED DRAWING NO: 11110� "M () ,04 0 0 1 PARTIAL GROUND FLOOR TEMPORARY SPOT COOLING & DEMOLITION PLAN °® 2f 4' 8' 40-114- 2 PARTIAL ROOF DEMO. PLAN 4' 8p 16' ., �� SHEET NO: 2 OF 5 SCALE: U4-T-0' 1/41' = 1 -0 SCALA 'V8'-I'-0' 1/891 = 11-019 + - ...... ___ _.._._.._ _ _ .. __ __ F- - ___ .._ .......___. _ ......___....... ..._ __ CONSTRUCTION KEY NOTES O L v ( BE-NCH 1A 100.01 339- 01-01 1. REMOVE AND REPLACE TWO (2) EXISTING 3P/125A CB'S WITH 3P/110A CB'S TO SERVE NEW A/C UNITS. NEW CB'S SHALL MATCH EXISTING TYPE AND INTERRUPTING RATING. DC POWER ROOM --I 2. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE FOR DISCONNECT AND CIRCUITRY INFORMATION. COMP/DEHY. RM I 3. FURNISH AND INSTALL A DUPLEX RECEPTACLE WITHIN THE BAS ENCLOSURE FOR PLUG-IN OF NEW PANEL. j f 4. FURNISH AND INSTALL ENCLOSED POWER SUPPLY FOR LEAK DETECTORS, FUNCTIONAL DEVICES, INC. MODEL #: I I PSH2OOA-LVC. 8V BAT A & � LM ISWITCHING. REFER TO LIGHTING- 5. NEW TYPE A, A-EM AND EX FIXTURES. WIRE TYPE EM AND EX FIXTURES AHEAD OF Jacobsen & Horan NL _ FIXTURE SCHEDULE FOR DETAILS. (TYP. 2 i�2R _ .._ PO��ERSAFE G f ) - 6. WIRE NEW MER GFI RECEPTACLES TO 1 P/20A CB IN PANEL PPAC. REFER TO PANEL SCHEDULE FOR MORE Engineering, P.C. kDFB INFORMATION. CIRCUITING NOT SHOWN FOR CLARITY. 990 South 2nd Street 7. CONNECT TO EXISTING LOCAL LIGHTING CKT. Ronkonkoma, NY 11779 0101 O: (631 580-6100m. P L ..___ _....... __ 8. FURNISH AND INSTALL NEW 1P/20A CB IN EXISTING PANEL LP1A. NEW CB SHALL MATCH EXISTING TYPE AND F: (631) 580-6101 .. .._... .......�.. �_.. _.._.._._..........-..__...-.........._....-......___�.._...�... �mm I � _.�..___... INTERRUPTING RATING. www.jhepc.com 9. FURNISH AND INSTALL TWO (2) NEW FIRE SHUTDOWN RELAYS. I 10. FURNISH AND INSTALL NEW CEILING MOUNTED SMOKE DETECTOR. IT I�eS A woLATION of NEW YORK STATE EDUCATION LAW FOR ANY �� NEW STATE PERSON, UNLESS ACTING UNDER 11. FURNISH AND INSTALL NEW DUCT DETECTOR IN THE SUPPLY. CONNECT TO EXISTING CERBERUS PYROTRONICS �'�P �. JACO 0,9 THE DIRECTION OF A LICENSED -- — -,•••. - — - - _ """ "' _E. �, PROFESSIONAL ENGINEER, TO __ - ` F - _._ � - CP-35 FIRE ALARM CONTROL PANEL. CONFIRM DUCT SIZES WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING J ti"�' � ALTER AN ITEM ON THIS DRAWING SAMPLING TUBES. * Q Cn * IN ANY WAY. IF AN ITEM IS ( l� �v ALTERED, THE ALTERING ENGINEER _ I _-__ .` - ,i c ` SHALL AFFIX TO THE ITEM - _.- - - 12. FURNISH AND INSTALL A NEW DUCT DETECTOR IN THE RETURN DUCT AND FOUR (4) PHOTOELECTRIC SMOKE m ,I �, w HIS/HER SEAL AND THE NOTATION ALTERED BY" FOLLOWED BY �' MDP SECT. 2 DETECTORS IN FRONT OF THE EXISTING 72x40 RETURN AIR GRILLE ASSEMBLY IN ACCORDANCE WITH NFPA 72, F � v` HIS/HER SIGNATURE AND THE 5ESS DIG. SW. ; ( ) SECTION 17.7.5.4.2.2. CONNECT TO EXISTING CERBERUS PYROTRONICS CP-35 FIRE ALARM CONTROL PANEL ON �,o °76462 c`? DATE OF SUCH ALTERATION AND A _._._... -.,. __ ......Y., THE SAME ZONE. CONFIRM DUCT SIZE WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING SAMPLING TUBES. 9�FESS►ON�� DESCRIPTION OF THE __•_,_•_,•••_•••• ALTERATION I p 1 ( I zzt 13. MODIFY EXISTING CERBERUS PYROTRONICS CP-35 FIRE ALARM SYSTEM AS REQUIRED TO ACCOMMODATE NEW CONSULTANT: �__._.. ... _ - ..... � __ _ _ - __ I DEVICES. ._.. ___... Y - 12-1 TECHNOLOGY DRIVE, MDP (SECT. 1) SETAUKET, NY 11733 14. UPDATE FIRE ALARM ZONE MAP FOR THE ENTIRE FLOOR. ;:.... I P. 631.689.8450 F. 631.689.8459 .' -- -' "•'~"" � www.wfcaia.com f I .I.,...._.__._...—........... ............_............-..,.. ..-.. ..�. -f i __._........_...w.. I T E C T S EMG. ENGINE RM. �" NO. DATE SUBMISSION I . ,•, � I _......_...._....... .. __�_� I� 1 10/10/17 ISSUED FOR BID _ _._ __ .... - _ _ _ - L _ _ L_ _ - _ _ _._.. __.. _ _ � I _ _.._ _.___.__ i' 2 11/02/17 ISSUED FOR FILING f I BOILER RM -_ - F T _1 ___.. __._ ....__F.. _ _...._T — --I._.__ ____ — F T � � � � � � _ _ _1 F _111 I -•-•-• � � ,. T L__ _. _ — J .._ _._ _ .._ _... ._..- 3 �.. F-71 i iLEX 3 ... 4 3 7 5 KEY PLAN: 650-01-01 5ESS/TOLL STORERM ._ 5ESS MTCE. CTR. EX 2T . 34 0 PP PA i �a q" L... 6 5 PPAC-10 PPA �. A-EM -..-.........__... C;-9 PPAC-12 q 11 I SDS 5 ---- _........._..........-... _....._.......... ;�._......___._..._ ._ �„. ...„.....,......_ �............._. it .II �, s�...` 10 f ,. , Li 313-01-02 U) A 9 S ? ARFA OF WORK ♦pi 2 12 S ' j..................__.................._.._...,............_........._..,...._....._.....,..._._..._...................._..,..._..,., I P P II MECH. 341- OS 2 2 " E `• A-EM EQPT. RM 01-01 .,„.......i.....................� `FA mp CARRIER EQPT. P P A-EM 340- 474-1R !' 210-1R-02 TOLL ADMIN01-01 -02A/B 313-0'1-01 PPAC 2 f , f I 1 A PPAC 210-1 R-01 - _ - j n ( I I EXE, € f 474-1 R . . 1 -01 A B - = -: �` , A/C REPLACEMENT 474-1 R-01 A/B FOR CARRIER SWRM CO STOR PPAC-13 LOCKER & LOUNGE I PPAC-14 31755 MAIN RD. CUTCHOGUE NY GROUND FLOOR 12 (._....— _....._... I TITLE: S zM I GROUND FLOOR & ROOF ••--••,- DR CONSTRUCTION KEY NOTES OX CONSTRUCTION PLANS 14 1. ROUTE CONDUIT/WIRE USING EXISTING PITCH POCKET. SUPPORT CONDUIT FROM DUNNAGE F' WHERE POSSIBLE AND PIPE SUPPORT (PROVIDED BY MC). REFER TO MECHANICAL DATE: 8/16/17 EQUIPMENT CONNECTION SCHEDULE FOR DISCONNECT AND CIRCUITRY INFORMATION. REFER TO DRYCOOLER PUMP PACKAGE WIRING DETAIL FOR MORE INFORMATION. PROJECT NO: 17-2165 .'� , DRAWN BY: LAS UNISEX TLT�. 2. LIGHTING AND GFI RECEPTACLE ASSEMBLY. REFER TO MOUNTING SUPPORT DETAIL FOR MORE CHECKED KJH / P S MDF i INFORMATION. CONDUIT NOT SHOWN FOR CLARITY. ! SCALE: AS NOTED 3 DRAWING NO: 1 PARTIAL GROUND FLOOR CONSTRUCTION PLAN 2' 4' $' 2 PARTIAL ROOF CONSTR. PLAN 4' s' 16' r= 024oOO 144E: / SHEET NO: 3 OF 5 9CHLE U4 O'f-0' 1/4 = 1 -0 SCALlG V8V814-91 8„ = 1 -0„ INCOMING POWER FEED (REFER TO SCHEDULES FOR MORE INFORMATION). NEMA 3R NON-FUSED HEAVY DUTY DISCONNECT SWITCH. SEE TABLE BELOW (NOTE 1). DRYCOOLER CONTROL PANEL. DS SEE TABLE BELOW (NOTE 2). Jacobsen & Horan FURNISHEDRYCOOLER D AND P1 M Engineering, P.C. INSTALLED BY MC, J GLYCOL PUMPS P1 AND P2. SEE 990 South 2nd Street WIRED BY EC. AWP MECHANICAL DRAWINGS FOR HP PPAC P2 9779 1 NY Ronkonkoma, RATING. REFER TO TABLE BELOW VOLTAGE: 120/208 BUS RATING: 225A CU M FOR WIRING DETAILS. PHASE: 3 FED FROM EXISTING 3P/200A CB LOCATED DISTRIBUTION PANEL MDP (SECTION 1) MAIN: MLO O: (631) 5, NY 1 0 TERMINATE PUMP WIRE: 4 CONDUCITORS AT AIC: 65 KAIC FULLY RATED F: (631) 580-6101 CKT TRIP LOAD VA PER PHASE LOAD TRIPCKT www.jhepc.com STARTER IN DUAL PUMP PACKAGE NO LOAD DESCRIPTION P AMP VA BRANCH CIRCUIT A B C NO.BRANCH CIRCUIT VA AMP P LOAD DESCRIPTION DRYCOOLER CONTROL PANEL (PROVIDED BY MC). 1 DRYCOOLER 210-1 R-01 2954 348 + 1410G, 3/4" RA CDT 5908 348 + 1410G, 3/4" RA CDT 2954 DRYCOOLER 210-1 R-02 2 pF NF IT IS VIOLATION OF NEW YORK (TYP-2).. LIQUID TIGHT FLEXIBLE NON—METALLIC 3 3 35 2954 VIA LOCAL NFDS VIA LOCAL NFDS �c W 5908 2954 35 3 j- STATE EDUCATION LAW FOR ANY CONDUIT WITH CONDUCTORS TO MOTOR. 4 P E JACO 0,� PERSON, UNLESS ACTING UNDER NEMA 3F2 NON—FUSED HEAVY DUTY 5 2954 5908 2954 6 �,,,, 6 � THE DIRECTION OF A LICENSED PROVIDE PLASTIC BUSHINGS OR * CP PROFESSIONAL ENGINEER, TO DISCONNECT SWITCH. SEE TABLE BELOW GROMMETS WHERE THE FLEXIBLE 7 RETURN FAN 340-01-01 1 20 780 2412 + 1412G, 3/4" EMT 946 2412 + 1412G, 3/4" EMT 166 15 1 OUTSIDE AIR FAN 341-01-01 8 d' ALTER AN ITEM ON THIS DRAWING FOR RATING (TYP-2). IN ANY WAY. IF AN ITEM IS CONDUITS PENETRATE THE PUMP PACKAGE 9 MER REC. 1 20 720 2-#12 + 1-#12G, 3/4" EMT 920 2-#12 + 1-#12G, 3/4" EMT 200 20 1 LEAK DETECTOR PWR SUPP. 10 ;, i' � ca: SHRED, T TO ALTERING ENGINEER E ITEM ENCLOSURE (TYP). 11 MER LTG 1 20 129 2412 + 1412G, 3/4" EMT 609 2412 + 1412G, 3/4" EMT 480 20 11 BAS PANEL 650-01-01 12 m� sj`_- �zHIS/HER SEAL AND THE NOTATION 13 ROOF REC. 1 20 360 2-#10 + 1-#10G 3/4" RA CDT oT ALTERED FOLLOWED BY 464 2-#10 + 1-#10G, 3/4 RA CDT 104 20 1 ROOF LTG 14 p 6462 HIS/HER SIGNATURE AND THE DATE OF SUCH 208V PUMP PACKAGE WIRING DETAILS 15 SPARE 1 20 20 1 SPARE 16 �CFESS►ONP� SP CIFIIC DESCRPTIONAOIF THED A 17 SPARE 1 20 ALTERATION. 20 1 SPARE 18 PUMP DISCONNECT 19 TEMP SPOT COOLER 2450 TEMPORARY WIRING AS 4900 TEMPORARY WIRING AS 2450 TEMP SPOT COOLER 20 CONSULTANT: PUMP HP NOTE 1: WIRE/CONDUIT FROM DRYCOOLER NOTE 2: WIRE/CONDUIT TO INDIVIDUAL PUMPS SWITCH RATING 21 3 30 2450 REQUIRED 4900 REQUIRED 2450 30 3 22 i. �� � 12-1 TECHNOLOGY DRIVE, 23 2450 SETAUKET, NY 11733 4900 2450 24 UP TO 3 6-#12 + 2-#12 GROUNDS, 3/4" RA 3-#12 + 1-#12 GROUND, 3/4" RA 30A 25 TEMP SPOT COOLER 2450 TEMPORARY WIRING AS 4900 TEMPORARY WIRING AS 2450 TEMP SPOT COOLER 26 \, F. 631.689.8450 27 3 30 2450 REQUIRED REQUI RED F. 631.689.8459 4900 2450 30 3 5 6-#10 + 2-#10 GROUNDS, 3/4" RA 3-#10 + 1-#10 GROUND, 3/4" RA 30A 28 www.wfcaia.com 29 2450 4900 2450 30 7 1/2 6—#8 + 2—#10 GROUNDS, 1" RA 3—#8 + 1—#10 GROUND, 3/4" RA 30A VA PER PHASE 17117 16628 16317 I T E C T S AMPS PER PHASE 143 139 136 10 6—#6 + 2—#10 GROUNDS, 1-1/4" RA 3—#6 + 1—#10 GROUND, 3/4" RA 60A TOTAL CONNECTED LOAD, VA 50061 TOTAL CONNECTED LOAD, AMPS 1139 NO. DATE SUBMISSION NOTES: 1 10/10/17 ISSUED FOR BID 15 6—#3 + 2—#8 GROUNDS, 1-1/2" RA 3—#3 + 1—#8 GROUND, 1" RA 60A 1. THE DESIGN IS BASED UPON A CUTLER HAMMER PRL2A 6. BRANCH DEVICES BASED UPON TYPE GHB CB'S. 2 11/02/17 ISSUED FOR FILING 2. PANEL SHALL HAVE NOMINAL DIMENSIONS OF 48"H x 20"W x 5.75"D. 7. PANEL SHALL HAVE TYPE WRITTEN PANEL DIRECTORY LOCATED INSIDE WELDED 3. PANEL SHALL HAVE NEMA 1 ENCLOSURE. METAL FRAME ON THE INSIDE OF DOOR. 4. PANEL SHALL HAVE COPPER BUS. 18. PROVIDE PHENOLIC NAMEPLATE WITH ADHESIVE BACKING AND 1/4" TEXT 5. PANEL SHALL PERMANENT CIRCUIT NUMBERS INDICATING PANEL NAME. &SCALENONE RYCOOLER/PUMP PACKAGE WIRING DETAIL EQUIPMENT CONNECTION SCHEDULE DISC_ SWITCH @ UNIT(3) (5) RECEPTACLE DESIG. LOAD MOCP UNIT VOLTS PHASE POLE FRAME FUSE STARTER(2) CIRCUIT(1) CIRCUIT REMARKS WEATHERPROOF JUNCTION BOX MOUNTED BEHIND 313-01-01 74.8 110 A 208 3 3 200 NF (6) LIGHTING FIXTURE. - - 313-01-02 74.8 110 A 208 3 3 200 NF (6) KEY PLAN: 13W LED FLOODLIGHT, RAB MODEL <. . 210-1R-01 24.6 35 A 208 3 3 60 NF PPAC-1,3,5 HBLED13B (TYP. OF 2) 210-1R-02 24.6 35 A 2083 3 60 NF PPAC-2,4,6 ! ` 474-1 R-01 A&474-1 R-01 B 10.6 - A 208 3 3 30 HOT—DIPPED GALVANIZED STEEL STRUT (TYP.) - i ' 474-1 R-02A&474-1 R-02B 10.6 - A 208 3 3 30 3/4" RA CONDUIT (TYP.) 339-01-01 5.8 15 A 120 1 (4) (7) 1 i i WEATHERPROOF JUNCTION BOX MOUNTED TO '' 340-01-01 6.2 20 A 120 1 (4) PPAC-7 CROSS—STRUT TO INCLUDE A 20A WEATHERPROOF ? I I i 341-01-01 5.8 15 A 1 120 1 1 (4) 1 PPAC-8 " LEVER LIGHT SWITCH (HUBBELL CAT # 5137-0). NOTES: 1 . 0I (1) PROVIDE WP/GFI RECEPTACLES WITHIN 25'OF UNIT. CONNECT TO CIRCUIT INDICATED. (6)WIRE 341 +#6G 1N 1-1/4" EMT FROM NEW 3P/110A CB'S IN WEATHERPROOF JUNCTION BOX MOUNTED TO ! ' ao (2) COMBINATION STARTER UNLESS NOTED OTHERWISE. DISTRIBUTION PANEL MDP(SECT2) LOCATED IN THE EMG. ENGINE RM. ' CROSS—STRUT TO INCLUDE A 20A GFCI RECEPTACLE I W/ METALLIC WHILE—IN—USE COVER. {3) FURNISHED AND INSTALLED BY DIVISION 26 UNLESS NOTED OTHERWISE. (7)WIRE 2412+#12G IN 3/4" RA CDT FROM NEW 1P/20A CB IN EXISTING i (HUBBELL CAT # 5735-0) (4) FURNISHED BY DIVISION 23 AND INSTALLED &WIRED BY DIVISION 26, PANEL LP1A LOCATED IN THE DC POWER ROOM. _41 } i (5) NEMA 31R.HOUSING FOR OUTDOOR EQUIPMENT. #10 CONDUCTORS RUN IN 3/4" RA CONDUIT TO ...::_ TWO (2) 1 P/20A CBS IN NEW PANEL PPAC LOCATED IN THE MER BELOW. I i ARFA OF WORK SUPPORT FROM DRYCOOLER UNIT AND STEEL DUNNAGE USING GALVANIZED STEEL STRUT AND LIGHTING FIXTURE SCHEDULE STAINLESS STEEL HARDWARE. - l//%f!/!ll! /�ff!li�fll�/!/7! �i/2/////f!!/ /�',r//77//'/!/ /;/ /// ROOF SURFACE. SYMBOL DESCRIPTION VOLTS LAMPS WATTS MOUNTING MANUFACTURER / MODEL NO. D PENDANT OR WALL MERCURY LIGHTING / ) A OR 4' LINEAR LUMINAIRE UNV LED 43 MOUNT AS SHOWN LW3-4-4500-35K—HTA—UNI 2 LIGHTING FIXTURE DETAIL A-EM AT 8'-0" A.F.F. OR EQUAL BY LITHONIA SCALE NONE ®EX EXIT SIGN UNV LED <5 WALL MOUNT ATLITE / XLN1-6SR1 AS SHOWN A/C REPLACEMENT FOR CARRIER SWRM PANEL DESIGNATION SWITCH DESIGNATION AMPS, VOLTAGE, PHASE, # CONDUCTORS FED FROM: SOURCE 31755 MAIN RD. FED FROM: SOURCE CUTCHOGUE, NY GROUND FLOOR PANELBOARD EXAMPLE: DISCONNECT SWITCH EXAMPLE: TITLE: P D S C—5 01 CU-1 DETAILS & SCHEDULES 400A, 120/208V, 3PH, 4W FED FROM: PP-2B, CKT #1,3,5 FED FROM: ACB-11 (BASEMENT) (1ST FLOOR) DATE: 8/16/17 NOTES: PROJECT NO: 17-2165 1. LABEL SHALL BE PERMANENT, SCREW-ON, PHENOLIC NAMEPLATE WITH BLACK BACKGROUND AND WHITE LETTERING. DRAWN BY: LAS 2. 1ST LINE LINE (DESIGNATION) SHALL HAVE 1/4" HIGH LETTERING. CHECKED BY: KJH / PEJ 3. ALL OTHER LINES SHALL HAVE 3/16" HIGH LETTERING. SCALE: NONE 4. AMPERAGE FOR PANELBOARDS SHALL INDICATE OVERCURRENT PROTECTION, NOT PANELBOARD BUS RATING. DRAWING NO: JOAL 000 3 TYPICAL PHENOLIC LABEL DETAIL 4 SCHEDULES SCALE NONE SCAM POPE SHEET NO: 4 OF 5 1. WORK INCLUDED ASSEMBLIES SHALL BE LISTED BY THE LABORATORIES AS A 2.2.6. GROUND WIRE SHALL BE COPPER WITH TYPE RHW GREEN INSULATION 2.5.9. SEPARATE SUPPORTS CONSISTING OF FORMED STEEL AND RODS SHALL 2.10.6. PROVIDE ALL FRAME SUPPORTS, BACKBOARDS AND THE LIKE FOR - "RECOGNIZED COMPONENT." COMPONENTS NOT SO LISTED OR WITH A TEXTILE OR COTTON BRAID JACKET. BE PROVIDED UNDER THIS DIVISION TO SUSPEND ALL RECESSED PROPER MOUNTING OF ALL STARTING AND DISCONNECT EQUIPMENT 1.1. SCOPE OF WORK MARKED WILL NOT BE ACCEPTED IF LISTED OR MARKED COMPONENTS 2.3. LIGHTING, POWER AND DISTRIBUTION PANELS AND/OR SURFACE (OR STEM) MOUNTED LIGHTING FIXTURES INSTALLED UNDER THIS DIVISION. ANGLE IRON OR CHANNEL 1.1.1. GENERAL DESCRIPTION OF WORK ARE AVAILABLE FROM ANOTHER MANUFACTURER. ALL EQUIPMENT MUST 2.3.1. WHEREVER INDICATED, CONTRACTOR SHALL PROVIDE NEW DISTRIBUTION INDEPENDENTLY OF CEILING CONSTRUCTION (PLASTER, SHEET ROCK, (UNISTRUT, B-LINE, KINDORF, ETC.) FRAMES, RACKS AND BACKBOARDS 1.1.1.1. THIS WORK SHALL INCLUDE ALL LABOR, MATERIALS, EQUIPMENT AND HAVE MET APPROVAL. AND POWER PANELS OR UTILIZE AVAILABLE SPARE BRANCH CIRCUITS ETC.). HANGERS SHALL BE FULLY ADJUSTABLE TO ALLOW FIXTURE SHALL BE OF ADEQUATE DIMENSIONS TO PERMIT AN ORDERLY SERVICES NECESSARY FOR THE COMPLETE INSTALLATION, DEMOLITION 1.1.12. CUTTING, ALTERING AND PATCHING WITHIN EXISTING PANELS AS INDICATED ON THE DRAWINGS. LEVEL TO COINCIDE WITH THE FINISHED CEILING LEVEL, AND SHALL BE ARRANGEMENT OF EQUIPMENT AND CONDUIT CONNECTIONS THEREIN. AND RENOVATION OF ALL ELECTRICAL AND RELATED WORK, COMPLETE 1.1.12.1. THE SUBCONTRACTOR SHALL DO ALL CUTTING, CORE DRILLING, 2.3.2. WHERE NECESSARY, CONTRACTOR SHALL PROVIDE NEW FUSES/BREAKERS SECURELY FASTENED TO THE STRUCTURAL MEMBERS OF THE BUILDING 2.10.7. CONTRACTOR SHALL, WHEN NEEDED BY THE PROGRESS OF THE JOB, AND READY FOR OPERATION AND IN STRICT ACCORDANCE WITH THE ALTERING AND PATCHING AS REQUIRED FOR THE INSTALLATION OF COMPATIBLE WITH EXISTING PAN ELBOAR D/SWITC H BOARD. FUSES, WHERE CONSTRUCTION. WHERE RECESSED LIGHTING FIXTURES ARE INDICATED REQUISITION THE STARTERS FROM THE TRADES INVOLVED. CONTRACTOR VERIZON STANDARDS, WHERE APPLICABLE, LOCAL AGENCY THE WORK OF ALL TRADES EMPLOYED UNDER THIS CONTRACT, REQUIRED, SHALL BE AS MANUFACTURED BY BUSSMAN OR EQUAL. TO BE INSTALLED IN AREAS OF SUSPENDED ACOUSTIC TILE OR PANEL SHALL THEN RECEIVE, STORE, UNCRATE, CLEAN, DISTRIBUTE TO POINTS ORDINANCES, AND THE CONTRACT DRAWINGS, OR AS REASONABLY INCLUDING THE RESTORING OF EXISTING WORK THAT IS DAMAGED 2.3.3. CONTRACTOR SHALL RE-LABEL ALL BRANCH CIRCUITS CLEARLY, IN ALL CEILINGS, THE FIXTURE SHALL BE INDEPENDENTLY SUPPORTED BY THE OF USE AND ACCEPT ALL RESPONSIBILITY FOR SAME AS OUTLINED SPECIFIED HEREIN OR IMPLIED. AND/OR ALTERED DUE TO REMOVAL WORK. ALL MATERIALS AND AFFECTED PANELBOARDS, TO INDICATE THE EQUIPMENT/DEVICES THEY ELECTRICAL CONTRACTOR. HEREINBEFORE. 1.1.1.2. ALL WORK SHALL BE PERFORMED BY QUALIFIED LICENSED WORKMANSHIP REQUIRED IN CONNECTION WITH CUTTING, ALTERING SERVE. 2.5.10. HANGER RODS, WHERE UTILIZED, SHALL BE COLD ROLLED THREADED 2.10.8. OBTAIN ALL INFORMATION REGARDING THE TYPE, CONNECTION, CURRENT ELECTRICIANS. AND PATCHING SHALL MATCH THE EXISTING WORK IN EVERY RESPECT. 2.3.4. NEW PANELBOARDS SHALL BE 208 VOLT RATED, 3-PHASE, 4-WIRE, STEEL ROD, A MINIMUM OF 1/4" IN DIAMETER. CHARACTERISTICS, ETC., OF ALL ELECTRICAL EQUIPMENT AND MOTORS 1.1.1.3. IT IS UNDERSTOOD ,AND AGREED BY THE CONTRACTOR THAT THE 1.1.12.2, PROVIDE AND PLACE REQUIRED SLEEVES, FORMS AND INSERTS CIRCUIT BREAKER TYPE, UNLESS OTHERWISE NOTED, WITH GROUND BUS. 2.5.11. CONTRACTOR SHALL PROVIDE NEW CONCRETE INSERTS AS REQUIRED FROM THE TRADES SUPPLYING SAME. THE WORK OF THIS DIVISION WORK AS INDICATED( AND DESCRIBED ON THE DRAWINGS AND/OR BEFORE WALL OR PARTITIONS ARE BUILT. ALL CIRCUIT BREAKERS ARE TO BE BOLTED TYPE. FOR ALL CONDUIT SUPPORTS. EXISTING INSERTS, BEAMS, SUPPORT SHALL INCLUDE RESPONSIBILITY FOR THE SAFE AND PROPER SPECIFICATIONS SHALL BE COMPLETE AND SHALL INCLUDE ALL 1.1.12.3. WHEN IT BECOMES NECESSARY TO CUT FINISHED MATERIALS, SUBMIT 2.3.5. BUS BARS SHALL BE HARD DRAWN COPPER, MINIMUM 98% CONDUCTIVITY CHANNELS MAY BE UTILIZED BY THE CONTRACTOR WHERE FEASIBLE OPERATION OF THE MOTORIZED EQUIPMENT TO THE EXTENT THAT IT IS EQUIPMENT NECESSARY FOR THE PROPER FUNCTIONING OF THE TO THE ENGINEER DRAWINGS SHOWING THE WORK REQUIRED AND SILVER OR TIN PLATED JOINTS. AND WHERE THE EXISTING EQUIPMENT IS ACCEPTABLE FOR THE AFFECTED BY THIS WORK. SYSTEMS, EVEN THOUGH EVERY ITEM INVOLVED IS NOT SPECIFICALLY OBTAIN COMMENTS BEFORE DOING SUCH CUTTING. 2.3.6. CABINETS SHALL BE GALVANIZED SHEET STEEL BACK BOX, DOOR AND ADDITIONAL LOADING. APPROVAL TO UTILIZE ANY EXISTING SUPPORT 2.10.9. COOPERATE WITH THE TRADES OF THE OTHER DIVISIONS IN MAKING SHOWN OR MENTIONED. THE CONTRACTOR SHALL BE HELD TO 1.1.13. RELATIONS WITH OTHER TRADES TRIM WITH DOOR-IN-DOOR CONSTRUCTION. FRONT COVER (TRIM) EQUIPMENT MUST BE AUTHORIZED IN ADVANCE BY VERIZON. ALL THE TESTS REQUIRED TO ASSURE THAT SUCH OPERATION IS Jacobsen & Horan PROVIDE ALL LABOR; AND MATERIALS NECESSARY FOR THE ENTIRE 1.1.13.1. COORDINATE WORK WITH ALL OTHER TRADES. CONFER WITH ALL COMPLETELY HINGED ON ONE SIDE WITH INDICATING TRIM CLAMPS ON 2.5.12. VERTICAL RUNS OF WIRING IN CONDUIT SHALL BE SUPPORTED AT ACHIEVED. ANY SPECIAL ELECTRICAL EQUIPMENT REQUIRED FOR THESE OTHER SIDES, SO AS TO COMPLETELY EXPOSE BREAKER ASSEMBLY AND INTERVALS AS REQUIRED BY CODE BY INTRODUCING SPLICE BOXES TESTS SHALL BE MADE AVAILABLE AS PART OF THE WORK OF THIS COMPLETION OF THE WORK INTENDED TO BE INDICATED OTHER CONTRACTORS HOSE WORK THIS INSTALLATION, WIRING GUTTERS WHEN COVER IS OPENED. ALL PANELBOARDS SHALL BE (PULL BOXES) AND UTILIZING APPROPRIATE WIRE HANGING FITTINGS. DIVISION. DESCRIBED AND SHALL NOT AVAIL HIMSELF OF ANY MANIFESTLY AND ARRANGE ALL PARTS OF THIS WORK AND EQUIPMENT IN PROPER UNINTENTIONAL ERRORS OR OMISSIONS, SHOULD SUCH EXIST. RELATION TO THE WORK AND EQUIPMENT OF OTHERS, WITH THE KEYED ALIKE. 2.10.10. PROPERLY PHASE OUT ALL FEEDERS AND BRANCH CIRCUITS, AND Engineering, P.C. 2.5.13. PANELS MOUNTED I EXTERIOR OR DAMP WALLS SHALL BE SPACED MAKE SUCH CHANGES AND ALTERATIONS NECESSARY TO INSURE THE 990 South 2nd Street 1.1.2. WORK UNDER THIS BEC'T'ON BUILDING CONSTRUCTION AND WITH ARCHITECTURAL FINISH SO THAT 2.3.7. MINIMUM GUTTER SPACES SHALL BE AS FOLLOWS FOR ALL POWER AND OFF THE WALL A MINIMUM OF ONE INCH. CORRECT ROTATION OF ALL MOTOR DRIVEN EQUIPMENT. WORK UNDER THIS CONTRACT SHALL INCLUDE ALL LABOR AND IT WILL HARMONIZE IN SERVICE AND APPEARANCE. LIGHTING PANELS: 5-3/4" ON SIDES, TOP AND BOTTOM. 2.6. OUTLETS, JUNCTIONS AND PULL BOXES DISCONNECT SWITCHES Ronkonkoma, NY 11779 MATERIAL, FURNISHED AND INSTALLED AS IMPLIED BY THE 1.1.14. DAMAGE TO PROPERTY 2.3.8. PANELBOARDS SHALL BE EQUIPPED WITH DIRECTORY WHICH SHALL 2.6.1. FURNISH A GALVANIZED STEEL OUTLET BOX FOR EVERY OUTLET CALLED 2.1 1. DIDI PROVIDE ALL SERVICE AND EQUIPMENT DISCONNECT SWITCHES AS ELECTRICAL DRAWINGS. THE WORK IN GENERAL IS LISTED BUT 1.1.14.1. RESTORE TO ITS ORIGINAL CONDITION, WITHOUT EXTRA PAYMENT, ANY INCLUDE METAL FRAME HOLDER, CLEAR PLASTIC TRANSPARENT COVER, FOR ON THE DRAWING. OUTLET BOXES SHALL BE OF APPROVED 2.1 0: (631) 580-6100 NOT LIMITED TO AS FOLLOWS: OF THE OWNER'S PROPERTY THAT BECOMES DAMAGED DUE TO THE TYPEWRITTEN LIST INDICATING FEEDER CABLE AND CONDUIT SIZE, CIRCUIT DESIGN AND CONSTRUCTION OF FORM AND DIMENSION SUITABLY SHOWN ON THE DRAWINGS. 1.1.2.1. LIGHTING FIXTURES, INCLUDING LAMPS, OUTLET BOXES, FIXTURE WHIP, NEGLIGENCE OF EMPLOYEES. NUMBERS, OUTLETS SUPPLIED AND THEIR LOCATIONS. DISTRIBUTION ADAPTED TO ITS SPECIFIC LOCATION, THE KIND OF FIXTURE TO BE 2.11.2. ALL EQUIPMENT DISCONNECT SWITCHES NOT INCLUDED WITH EQUIPMENT F: (631) 580-6101 WIRE AND CONNECTIONS. 1.1.15. SHUTDOWNS PANELS SHALL BE PROVIDED WITH PHENOLIC PLATES TO IDENTIFY EACH USED, AND THE NUMBER AND ARRANGEMENT OF CONDUITS, AND SHALL BE PROVIDBE ED AS OWN ONE3R THE DRAWINGS ENCLOSURE STATED NDOORHEREIN www.jhepc.com 1.1.2.2. WIRING DEVICES, I.E., SWITCHES, RECEPTACLES, PLATES, JUNCTION 1.1.15.1. REQUEST FOR SHUTDOWNS MUST BE DELIVERED TO THE MANAGER OF CIRCUIT. CONDUCTORS ENTERING THERETO. AND BOXES, CONDUIT BODIES, CONDUIT FITTINGS, ETC. BUILDING OPERATIONS AT LEAST SEVEN (7) WORKING DAYS PRIOR TO 2.3.9. APPROVED MANUFACTURERS FOR PANELBOARDS SHALL BE EQUAL TO: 2.6.2. ALL BOXES SHALL BE FASTENED TO STRUCTURE WITH PROPER OR OUTDOOR APPLICATIONS RESPECTIVELY. UNLESS NOTED OTHERWISE, 1.1.2.3. BRANCH CIRCUIT WORK AT NEW PANELBOARDS, INCLUDING NEW THE REQUESTED SHUTDOWN AND SHALL BE SUBJECT TO THE FINAL 2.3.9.1. SQUARE "D" FASTENERS HANGERS AND FITTINGS. HEAVY DUTY, NON-FUSED, QUICK-MAKE, QUICK-BREAK. TYPE PROTECTIVE DEVICES, AS REQUIRED. APPROVAL OF THE BUILDING MANAGER. DISCONNECT SWITCHES SHALL BE USED. DISCONNECT SWITCHES WARNING: 2.3.9.2. CUTLER HAMMER 2.6.3. CEILING OUTLETS SHALL BE PROVIDED WITH FOUR-INCH OCTAGON IT IS A VIOLATION OF NEW YORK 1.1.2.4. GROUNDING, CABLES, BARS, ETC. 1.1.16. SHOP DRAWINGS 2.3.10. PANELBOARDS SHALL HAVE A MINIMUM INTERRUPTING CAPACITY OF STEEL OUTLET BOXES HAVING KNOCKOUTS ON THE TOP AND SIDES. SHALL BE GENERAL ELECTRIC OR WESTINGHOUSE, SQUARE "D" OR P�, �JAEW y0 STATE EDUCATION LAW FOR ANY 1.1.2.5. NEW PANELBOARD AND RESPECTIVE FEEDERS. 1.1.16.1. SUBMIT SHOP DRAWINGS OF ALL REQUIRED EQUIPMENT, PANELS, 22,000 AIC. FUSES SHALL BE RATED FOR A MINIMUM 100,000 AIC. 2.6.4. PROVIDE PRESSED STEEL BOXES FOR ALL SWITCH OUTLETS. WHERE EQUAL. 4 E Cp PERSON, UNLESS ACTING UNDER LIGHT FIXTURES, ACCESSORIES, HANGERS AND SUPPORTS, CONTROLS 2.1 1.3. DISCONNECT SWITCHES FOR SINGLE PHASE, 120V MOTORS SHALL BE '9 THE DIRECTION OFA LICENSED 1.1.2.6. EQUIPMENT IDENTIFICATION. 2.4. WIRING AND CONDUIT TWO OR MORE FLUSH SWITCHES ARE TO BE SET TOGETHER GANG ��' ��, � PROFESSIONAL ENGINEER, To 1.1.2.7. POWER FEEDERS TO ALL MOTORS AND MECHANICAL EQUIPMENT. AND WIRING DIAGRAMS. OBTAIN WRITTEN REVIEW COMMENTS BEFORE 2.4.1. ALL ABOVE AND BELOW-GRADE WIRING SHALL BE N.E.C. APPROVED, TYPE BOXES SHALL BE USED. TOGGLE TYPE. FUSED DISCONNECT SWITCHES SHALL BE USED 'WHERE "� Q Z * ALTER AN REM ON THIS DRAWING 1.1.2.8. DISCONNECT SWITCHES. IN ANY WAY. IF AN ITEM IS ORDERING OR INSTALLING ANY MATERIAL OR COMPONENTS. A MINIMUM THW, THWN-2, THHN, XHHW-2, RHW AND RHH OR AN APPROVED EQUAL, 2.6.5. JUNCTION BOXES SHALL BE NOT LESS THAN 4-11/16 INCHES SQUARE INDICATED ON THE DRAWING. r' '� t@ ALTERED, THE ALTERING ENGINEER 1.1.2.9. CABLE AND WIRING INCLUDING TERMINATIONS. OF 4 COPIES OF ALL SHOP DRAWINGS ARE TO BE SUBMITTED WITH UNLESS NOTED OTHERWISE ON DRAWINGS. BUILDING WIRE INSULATION AND SHALL BE EQUIPPED WITH BLANK PLATES. / 2.11.4. THE OPERATING MECHANISM OF ALL SWITCHES SHALL BE SO DESIGNED � , -- I'�; w SHALL AFFIX TO THE ITEM 1.1.2.10. CONDUITS. ONE COPY RETURNED TO THE CONTRACTOR. " _ u, HIS/HER SEAL AND THE NOTATION SHALL BE 600V, RATED NOT LESS THAN 90 DEGREES CELSIUS, WET OR 2.6.6. THE OUTLETS FOR LOCAL SWITCHES SHALL BE INSTALLED ADJACENT TO THAT THE SWITCHES MAY BE LOCKED IN THE ON OR OFF �� -; ���� ._ "ALTERED BY" FOLLOWED BY 1.1.2.11. SUPPORTS. 1.1.17. AS-BUILT DRAWINGS DRY. INSULATION SELECTION SHALL BE CONTRACTOR'S CHOICE, EXCEPT THE TRIM ON THE STRIKE SIDE OF THE DOOR, REGARDLESS OF THE POSITIONS. Fp p� HIS/HER SIGNATURE AND THE 1.1.2.12. NAMEPLATES. 1.1.17.1. FURNISH "AS-BUILT" DRAWINGS AS PART OF THE WORK OF THIS 2.11.5. EACH FUSED SAFETY SWITCH SHALL BE LEFT EQUIPPED WITH A ,09 sa62 `t`� DATE OF SUCH ALTERATION AND A 1.1.2.13. TEMPORARY LIGHT FIND POWER. WHERE SPECIFIC INSULATION TYPE OR RATING IS INDICATED OR CALLED LOCATIONS INDICATED ON THE DRAWINGS; THEREFORE, CHECK ALL OfiESS10NP SPECIFIC DESCRIPTION OF THE SECTION, CONSISTING OF A COMPLETE SET OF MYLAR/SEPIA FOR ON THE DRAWINGS. GROUND WIRES SHALL ONLY BE TYPE RHW WITH DOOR SWINGS BEFORE INSTALLING CONDUIT AND OUTLETS. COMPLETE SPARE SET OF FUSES. FUSES SHALL BE DUAL ELEMENT ALTERATION. 1.1.2.14. COORDINATION OF WORK WITH OTHER CONTRACTORS. TRANSPARENCIES AND TWO BLUELINE COPIES. INDICATING IN A NEAT TEXTILE OR COTTON BRAID JACKET. 2.6.7. WHERE FLUSH TYPE CEILING FIXTURES ARE TO BE INSTALLED, SET THE AND APPROVED BY THE MANUFACTURER FOR ITS INTENDED USE. 1.1.2.15. CONTINUITY OF EXISTING CIRCUITRY IN AREAS NOT AFFECTED BY NEW AND ACCURATE MANNER, A COMPLETE RECORD OF ALL REVISIONS TO 2.4.2. ALL WIRING UNLESS OTHERWISE SPECIFIED ON THE DRAWING OR HEREIN, OUTLETS TO ONE SIDE TO PERMIT THE INSTALLATION OF THE FIXTURES. 2.11.6. A DISCONNECT SWITCH SHALL BE PROVIDED AT ALL MOTORS. CONSULTANT: CONSTRUCTION THE ORIGINAL DESIGN OF THE WORK. SHALL BE RUN IN EMT OR RGS CONDUIT. ALL CONDUIT IN THE POWER EACH OUTLET SHALL BE LEFT WITH A BLANK COVER. 2.12. PROTECTION AND CLEANING 1.1.2.16. CUTTING AND CORE DRILLING. 2.12.1. ALL MATERIALS AND EQUIPMENT SHALL BE PROPERLY AND EFFECTIVELY (, 121 TECHNOLOGY DRIVE, 1.1.18. OPERATING AND MAINTENANCE MANUALS ROOM SHALL BE RIGID ALUMINUM. 2.6.8. RECEPTACLES HAVE BEEN MARKED ON THE DRAWINGS TO INDICATE SETAUKET NY 11 33 1.1.2.17. TESTING AND INSPECTIONS. 1,1.18.1. ON COMPLETION AND ACCEPTANCE OF THE WORK, FURNISH TO THE 2.4.3. ROMEX, BX (AC) AND/OR MC CABLE SHALL NOT BE PERMITTED. PREFERRED LOCATION; HOWEVER, THIS DOES NOT RELIEVE THE PROTECTED. CONDUITS MUST BE CAPPED DURING CONSTRUCTION SO ' ' 7 1.1.2.18. GUARANTEES. ENGINEER FOR REVIEW FOUR COPIES OF WRITTEN INSTRUCTIONS ON 2.4.4. ALL WIRING SHALL BE STRANDED ELECTRICAL GRADE COPPER. CONTRACTOR OF HIS RESPONSIBILITY TO INSURE THAT ALL AREAS ARE AS TO PREVENT OBSTRUCTION AND DAMAGE. ANY DAMAGE RESULTING P. 631.689.8450 1.1.2.19. PERMITS, FEES AND APPROVALS. �_ \ ,,. THE PROPER OPERATION AND MAINTENANCE OF ALL EQUIPMENT AND 2.4.5. WIRING SHALL BE SIZED TO HANDLE THE AMPACITY OF THE BRANCH FREE OF INTERFERENCES OR OBSTRUCTION WITH STRUCTURAL IN THE FAILURE TO USE PROPER PRECAUTIONS AS TO THIS WORK 1.1.2.20. INSURANCE. APPARATUS FURNISHED UNDER THIS SECTION, CONTAINING THE MEMBERS. SHALL BE REPLACED OR ALTERED TO THE SATISFACTION OF THE ,r, F. 631.689.8459 1.1.2.21. REMOVAL OF DEBRIS. CIRCUIT BEING SERVED. THE MINIMUM WIRE SIZE SHALL BE N0. 12 AWG vvww.wfcaia.com 1.1.2.22. CLEANING FOLLOWING: FOR ALL POWER AND LIGHTING SERVICES, UNLESS NOTED OTHERWISE ON 2.6.9. OUTLET BOXES FOR WEATHER OR VAPOR-PROOF FIXTURES SHALL BE OWNER. , 1.1.3. WORK UNDER OTHER SECTIONS 1.1.18.1.1. MANUFACTURERS MECH. EQUIPM T PARTS LIST OF ALL THE DRAWING. MALLEABLE IRON, WITH GASKETED COVER. WEATHERPROOF BOXES FOR 2.12.2• ALL ELECTRICAL EQUIPMENT SHALL BE PROTECTED BY HEAVY FUNCTIONAL COMPONENTS OF THE SYSTEM LISTED ON THE 2.4.6. COPPER CONDUCTORS IN VERTICAL RACEWAYS SHALL BE SUPPORTED AT TOGGLE SWITCHES OR RECEPTACLES SHALL BE 2-3/4 X 4-9/32 FIBERGLASS CLOTH COVERS. 1.1.3.1. THE FOLLOWING IS A GENERAL LISTING OF RELATED WORK INCLUDED EQUIPMENT SCHEDULES, DRAWINGS, CONTROL & WIRING INTERVALS NOT GREATER THAN THOSE SPECIFIED IN THE APPLICABLE "FD". 2.12.3. CONDUIT PULL BOXES OR EQUIPMENT THAT ARE TO BE PAINTED SHALL I T E C T S UNDER OTHER CONTRACTS: DIAGRAMS. LIST SHALL GIVE SYSTEM NUMBER, UNIT NUMBER, CODE. 2.6.10. JUNCTION AND PULL BOXES PROVIDED FOR CONDUITS ONE-INCH BE CLEANED TO REMOVE DIRT AND GREASE OR OIL. 1.1.3.1.1. GENERAL CONSTRUCTION MANUFACTURER'S MODEL NUMBER, AND MANUFACTURER'S 2.4.7. FINAL CONNECTION TO ALL EQUIPMENT SUBJECT TO MOTION OR TRADE SIZE AND LARGER, WHERE INDICATED OR AS NECESSARY TO 2.12.4. ALL CONDUIT, FIXTURES, EQUIPMENT AND APPURTENANCES SHALL BE 1.1.3.1.2. HVAC/MECHANIC,AL WORK THOROUGHLY CLEANED AND PUT IN FIRST-CLASS OPERATING CONDITION NO. DATE SUBMISSION 1.1.4. ALL APPLICABLE LOCAL, STATE AND NATIONAL CODES, STANDARDS AND DRAWING NUMBER. VIBRATION SHALL BE PERFORMED WITH LIQUID TIGHT FLEXIBLE CONDUIT, FACILITATE INSTALLATION OF THE WORK, SHALL BE CODE GAUGE BEFORE BEING OFFERED FOR ACCEPTANCE. REGULATIONS RELATING OR GOVERNING ANY POSITION OF THIS WORK 1.1.18.1.2• CLEAN COPY OF EACH FULLY PROCESSED SHOP DRAWING. AS MANUFACTURED BY AMER-TITE OR EQUAL. FLEXIBLE CONDUIT SHALL GALVANIZED STEEL, OF REQUIRED DIMENSIONS, WITH ACCESSIBLE, 2.13. FLASHING 1 10/10/17 ISSUED FOR BID ARE HEREBY MADE PART OF THESE SPECIFICATIONS INCLUDING BUT NOT 1.1.19. CONTRACT DRAWINGS NOT EXCEED S-0" IN ANY APPLICATION. REMOVABLE SCREW-ON COVERS. WHERE REQUIRED BY THE BUILDING/ 2.13.1. UNLESS NOTED OTHERWISE HEREIN OR ON THE DRAWINGS, PROVIDE A 2 11/02/17 ISSUED FOR FILING LIMITED TO THE FOLLOWING CODES OR RULES AND REGULATIONS: 1.1.19.1. THE ACCOMPANYING DRAWINGS ARE INTENDED TO SHOW THE GENERAL 2.4.8. MINIMUM CONDUIT OR EMT SIZE SHALL BY ,3/4" UNLESS SPECIFIED CONSTRUCTION, FURNISH AND INSTALL JUNCTION AND PULL BOXES IN METALLIC SLEEVE FOR ALL CONDUIT PENETRATIONS THROUGH WALLS, 1.1.4.1. NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION ARRANGEMENT AND EXTENT OF WORK TO BE PERFORMED. THE OTHERWISE. SPECIAL SIZES AND SHAPES DETERMINED IN THE FIELD. FLOORS AND CEILINGS. 1.1.4.2. AMERICAN NATIONAL STANDARDS INSTITUTE LOCATIONS FOR EQUIPMENT ANC MATERIAL AS SHOWN ON THE 2.4.9. WIRES SHALL BE COLOR CODED. GROUNDING CONDUCTOR SHALL HAVE A 2.6.11. PULL BOXES SHALL BE PROVIDED FOR ALL CONDUIT RUNS WHERE 2.13.2. CLOSE OFF SPACE BETWEEN CONDUIT AND SLEEVE WITH 1.1.4.3. UNDERWRITERS LABORATORIES DRAWINGS ARE APPROXIMATE. IT SHALL BE UNDERSTOOD THAT THEY GREEN COLOR. NEUTRAL SHALL HAVE A WHITE COLOR. THESE COLORS NECESSARY, AND AT MAXIMUM INTERVALS WHERE THE CHANGES IN ARE SUBJECT TO SUCH MODIFICATION AS MAY BE FOUND NECESSARY SHALL NOT BE USED FOR ANY OTHER PURPOSE. DIRECTION TOTAL 270 DEGREES (I.E., EVERY 3-90' TURNS). NON-COMBUSTIBLE INSULATION EQUAL TO FIRE RATING OF STRUCTURE. 1.1.4.4. NEPA 70; NATIONAL ELECTRIC CODE TO MEET JOB CONDITIONS. SUCH CHANGES SHALL BE MADE BY THIS2.13.3. ALL CONDUIT PENETRATIONS SHALL BE CORE DRILLED. 5 1.1.4. . NEPA 101; LIFE SAFETY CODE 2.4.10. CIRCUIT WORK BETWEEN OUTLET BOXES AND ALL LIGHTING FIXTURES 2.6.12. SIZES OF ALL BOXES SHALL CONFORM WITH THE MINIMUM 1.1.4.5. ADA REQUIREMENTS. CONTRACTOR AT NO ADDITIONAL CHARGE. SHALL BE PERFORMED WITH AN APPROVED FIXTURE WIRE. REQUIREMENTS OF THE APPLICABLE CODES UNLESS NOTED OTHERWISE 2.13.4. PROVIDE "PITCH POCKETS" FOR ALL CONDUIT PENETRATIONS THROUGH ROOF DECK. 1.1.4.7. NEW YORK CITY ELECTRIC CODE 1.1.20. EXAMINATION OF GENERAL CONSTRUCTION, HVAC, AND SPECIFICATIONS 2.4.11. SPLICES IN WIRES AND CABLES SHALL BE ELIMINATED WHENEVER ON THE DRAWINGS OR HEREIN. 2.14. NAMEPLATES AND IDENTIFICATION L ELECTRICAL SAFETY CODE 1.1.21. THE CONTRACTOR SHALL EXAMINE THE GENERAL CONSTRUCTION HVAC, POSSIBLE AND, WHERE NECESSARY, SHALL IBE MADE ONLY IN 2.7. DEVICES, PLATES AND SPECIALTIES - 1.1.4.8. THE 1.1.4.9. THE NATIONALVER ZON STANDARDS AND SPECIFICATIONS, INSOFAR AS LABOR AND MATERIALS AND TYPE OF ACCESSIBLE PULL OR JUNCTION BOXES, OUTLETS, SWITCH AND 2.7.1. ALL DEVICES SHALL BE OF PREMIUM SPECIFICATION GRADE, AND SHALL 2.14.1. EACH PANEL, SWITCH, ETC., SHALL HAVE A NAMEPLATE. THE CONSTRUCTION, ETC., THAT MAY AFFECT HIS WORK. THE SUBMISSION OF RECEPTACLE BOXES. BE LEVITON, SLATER, BRYANT, HUBBELL, GENERAL ELECTRIC OR EQUAL. NAMEPLATE SHALL BE MADE OF BLACK BAKELITE WITH WHITE ENGRAVED 1.1.4.10. OSHA A PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT SUCH „ LETTERS AT LEAST 1/4" HIGH. THE NAMEPLATES SHALL BE INSTALLED 1.1.4.11. THE NEW YORK STATE ENERGY CODE 2.4.12. BRANCH CIRCUIT WIRING FOR SINGLE PHASE APPLICATIONS MAY BE 2.7.2. ALL WALL SWITCHES SHALL BE 20A, 120V RATED, SEMI-SILENT TYPE, WITH SCREWS TO THE EXTERIOR OF THE EQUIPMENT. 1.1.5. SUBSTITUTIONS AND/OR EQUIVALENTS EXAMINATION HAS BEEN MADE AND NO LATER CLAIMS FOR EXTRA LABOR, MULTI-WIRE, UTILIZING COMMON NEUTRALS, EXCEPT WHERE OTHERWISE MOUNTED 4'-0" ABOVE THE FLOOR TO CENTERLINE OF THE SWITCH. 2.14.2. ANOTHER PLATE SHALL BE INSTALLED ON EACH PIECE OF EQUIPMENT EQUIPMENT OR MATERIALS WHICH COULD HAVE BEEN FORESEEN BY NOTED ON THE DRAWINGS. UNDER NO CIRCUMSTANCES SHALL ANY SWITCHES SHALL BE SINGLE, DOUBLE-POLE, THREE OR FOUR-WAY AS AS ABOVE WHICH STATES THE SOURCE PANEL AND CIRCUIT NUMBER 1.1.5.1. THE MATERIAL AND/OR EQUIPMENT AS SPECIFIED IN THE BID EXAMINATION WILL BE RECOGNIZED. SWITCH OR CIRCUIT BREAKER OPEN A NEUTRAL CONDUCTOR. REQUIRED AND AS INDICATED ON THE DRAWINGS AND SHALL BE EQUAL DOCUMENTS IS SELECTED TO INSURE A COMPLETE SYSTEM OF 2.4.13. THE CIRCUIT NUMBERS INDICATED ON THE PLANS ARE INTENDED AS A TO HUBBELL MODEL NO. 1200 SERIES. FEEDING THE NEW EQUIPMENT. 2.15. PAINTING SUITABLE QUALITY AND PROVIDE A STANDARDIZED COMPETITIVE BASIS 2. MATERIALS AND METHODS GUIDE FOR PROPER CONNECTION OF CIRCUITS AT PANELS. IT SHALL BE 2.7.3. WALL MOUNTED DUPLEX CONVENIENCE RECEPTACLES SHALL BE 20A, FOR ALL CONTRACTORS TO BID. THE RESPONSIBILITY OF THE CONTRACTOR TO SEE THAT THE CIRCUITING 2.15.1. ALL NEW PANELS AND CABINETS SHALL BE FACTORY-PRIME PAINTED, 1.1.5.2. THE INTENT OF THE BID DOCUMENTS IS THAT THE CONTRACTOR 2.1. TEMPORARY LIGHT AND POWER 120V RATED AND MOUNTED 1 -6 ABOVE THE FINISHED FLOOR TO FACTORY FINISHED AND, IF DAMAGED, SHALL BE TOUCHED UP OR KEY PLAN: WORK FULFILLS THE FOLLOWING CONDITIONS: SHALL INSTALL ALL EQUIPMENT AND MATERIALS AS SPECIFIED. 2.1.1. AS PART OF THIS CONTRACT, THE ELECTRICAL CONTRACTOR SHALL CENTERLINE OF THE OUTLET UNLESS NOTED OTHERWISE. ALL STANDARD REFINISHED AS DIRECTED AFTER COMPLETION OF THE INSTALLATION . 2.4.13.1. LOADS ON PANEL BUSSES SHALL BE BALANCED CN PHASES AS ( ) SHOULD THE CONTRACTOR DESIRE TO SUBSTITUTE ANOTHER MATERIAL PROVIDE ALL LABOR, PERSONNEL, PLANT, WIRING, EQUIPMENT AND EVENLY AS POSSIBLE. RECEPTACLES SHALL BE OF GROUNDED TYPE AND SHALL BE EQUAL TO 2.16. ACCESS PANELS OR VENDOR FOR GINE OR MORE SPECIFIED BY NAME, HE SHALL MATERIAL REQUIRED TO PROVIDE TEMPORARY LIGHT AND POWER FOR THE HUBBELL MODEL N0. 5362. 2.16.1. WHEREVER ANY OUTLETS, EQUIPMENT AND OTHER ITEMS REQUIRING l;___ .,;._ ;__ APPLY IN WRITING FOR SUCH APPROVAL AT TIME OF BID AND SHALL 2.4.13.2. NO NEUTRAL CONDUCTOR SHALL BE COIMMON TO MORE THAN ONE 2,7,4. STAINLESS STEEL COVER PLATES SHALL BE PROVIDED FOR ALL WALL ENTIRE AREA OF WORK, AND AS HEREINAFTER INDICATED; ALL IN CIRCUIT CONDUCTOR CONNECTED TO THIE SAME PHASE LEG OF THE SERVICE, ADJUSTMENT OR INSPECTION ARE CONCEALED AND REQUIRE STATE THE CREDIT IOR EXTRA INVOLVED. MOUNTED DEVICES. A COMMON PLATE SHALL COVER ALL DEVICES, °, ACCORDANCE WITH APPLICABLE CODES AND AGENCIES HAVING SUPPLY SYSTEM. ACCESS THROUGH FURRING, WALLS, FLOORS,OTHER CEILINGS, AND THE 1.1.5.3. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE SUPPORTING SIGNALS, ETC. WHICH ARE INDICATED AT THE SAME LOCATIONS. €I JURISDICTION. NO EXTRAS SHALL BE ENTERTAINED FOR FAILURE TO 2.4.14. NO WIRING SHALL BE PULLED INTO CONDU17 UNTIL THE CONDUIT AND 2.7,5• WALL-MOUNTED SWITCHES WITH INTEGRAL OCCUPANCY SENSORS SHALL ACCESS DOORS ARE NOT SPECIFIED UNDER OTHER CONTRACTS„ DATA AND SAMPLES„ IF NECESSARY, FOR A PROPER EVALUATION BY INCLUDE ANY OF THE ABOVE. BOX SYSTEM IS COMPLETE. FURNISH FACTORY MADE, COMPLETELY FINISHED, KEY-OPERATED, THE OWNER OR HIS DESIGNEE AT TIME OF SUBMITTAL. ADDITIONALLY, BE MODEL WA-200 AS MANUFACTURED BY THE WATT STOPPER, INC. , THE CONTRACTOR SHALL BE RESPONSIBLE TO REIMBURSE VERIZON 2.1.2. ALL TEMPORARY BRANCH CIRCUIT LIGHT AND POWER WIRING WITHIN THE 2.4.15. INSULATED BUSHINGS SHALL BE INSTALLED ON ALL OPEN CONDUIT ENDS. HEAVY METAL ACCESS DOORS AND FRAMES. BUILDING SHALL BE TYPE NMC 10 MIN. WITH GROUND WIRE. ALL 2.4.16. ALL EMT COUPLINGS AND FITTINGS SHALL BE COMPRESSION TYPE 2.7.6. CEILING-MOUNTED PASSIVE INFRARED OCCUPANCY SENSORS SHALL BE I 2.16.2. THE ACCESS DOORS SHALL HAVE THE SAME FIRE RATINGS AS THE FOR COSTS EXPENDED IN THE EVALUATION OF THE SUBSTITUTION, # MODEL CI-205 AS MANUFACTURED BY THE WATT STOPPER, INC. COMPOSITE CONSTRUCTION IS WHICH THEY ARE INSTALLED, AND BE A ;' ,I WHETHER OR NOT 1THE SUBSTITUTION IS APPROVED. FEEDER WIRING SHALL BE TYPE USE STYLE XHHW. FITTINGS. UTILIZE WEATHERPROOF FITTINGS FOR ALL CONDUIT IN DAMP 2.7.7• CONTRACTOR SHALL ADJUST THE LOCATION OF OCCUPANCY SENSORS pp 2.1.3. INSTALLATION TO PROVIDE LIGHTING SHALL INCLUDE FURNISHING AND OR WET LOCATIONS. TO ADEQUATELY COVER INTENDED AREA. MINIMUM R A X IM BUT IN NO CASE SHALL THEY BE LESS THAN 1.1.6. EXAMINATION OF EXISTING CONDITIONS " .; .Y � ' INSTALLING DOUBLE SOCKETS IN ALL AREAS AND, WHEREVER REQUIRED, 2.4.17. PROVIDE NYLON DRAG LINES IN ALL EMPTY CONDUIT AND SLEEVES. 2.8. GROUND FAULT PROTECTION 6 LARGER IN ALL DIMENSIONS THAT THE ITEMS SERVICED. r, 1.1.6.1. VISIT AND PRESENT LILY EXAMINE THOSE PORTIONS O THE SITE TO PROVIDE COMPLETE COVERAGE BY USE OF 40-FOOT EXTENSIONS. 2.4.18. METALLIC CONDUIT SHALL BE AS MANUFACTURED BY ALLIED TUBE AND 3. PROJECT COMPLETION F 1z AND/OR PRESENT BUILDINGS AFFECTED BY THIS WORK SO AS TO PROVIDE SINGLE SOCKETS AT EACH ENTRANCE. CONDUIT, WHEATLAND TUBE COMPANY OR EIQUAL. 2.8.1. GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLES (GFCI'S) SHALL BE 3.1. FINAL INSTALLATION .,,••• BECOME FAMILIAR WITH EXISTING CONDITIONS AND DIFFICULTIES THAT PROVIDED AS SHOWN ON THE DRAWINGS, AND OR ON ALL " 2.1.4. WORK AREA TO BE ILLUMINATED SUFFICIENTLY TO PROVIDE SAFE PASSAGE 2.4.19. CONDUITS SHALL BE SECURED IN PLACE AND PROTECTED TO PREVENT 3.1.1. ALL CONDUIT, WIRING AND EQUIPMENT SHALL BE THOROUGHLY � . . :. 11L �W„ WILL ATTEND THE EXECUTION OF THE WORK, BEFORE SUBMITTING THEREABOUT. POWER OUTLETS FOR EQUIPMENT ENERGIZATION BE DAMAGE TO THE WORK DURING CONSTRUCTION. ALL FIELD CUT CONDUITS RECEPTACLES OUTDOORS OR LOCATED WITHIN 6 OF A SINK. CLEANED AND PUT IN FIRST-CLASS OPERATING CONDITION BEFOREI'llA PROPOSALS. 2.8.2. WHERE INDICATED, GFCI RECEPTACLES SHALL BE EQUAL TO HUBBELL �, I� I PROVIDE THROUGHOUT NT POWER FOR ENT DAMAGE TO WIRE. UT ENTIRE WORKING SPACE, SUFFICIENT SHALL BE REAMED TO PREY D BEING OFFERED FOR ACCEPTANCE. �� 1.1.6.2. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT EQUIPMENT SUCH AS POWER SAWS, PIPE CUTTERS AND THREADERS, 2.4.20. THE ENDS OF ALL CONDUIT RUNS SHALL BiE PROVIDED WITH CAPS MODEL NO. GF5262. 3.1.2. UPON COMPLETION OF ALL INSTALLATION WORK, THE CONTRACTOR - ..... I 11 ' ''" SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, 2.9. LIGHTING FIXTURES AND EQUIPMENT „ HAND DRILLS, ETC. USE OF SOCKETS WILL BE PART OF BASIC DURING CONSTRUCTION TO AVOID FILLING WITH PLASTER, ETC. SHALL PREPARE FINAL AS-BUILT DRAWINGS REFLECTING ALL EQUIPMENT, OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES TEMPORARY LIGHT SYSTEM. 2.4.21. IN NO CASE SHALL CONDUIT BE RUN ABOVE OR WITHIN SIX INCHES OF 2.9.1. CONTRACTOR SHALL PROVIDE NEW INTERIOR LIGHTING FIXTURES, AND CIRCUITRY AS INSTALLED IN THE FIELD. THESE DRAWINGS SHALL BE AREA OF WORK J '11% ENCOUNTERED,ENCOUNTERED, WHICH COULD HAVE BEEN FORESEEN HAD SUCH 2.1.5. FURNISH AND INSTALL AS PART OF BASIC TEMPORARY LIGHT SYSTEM, HOT WATER, FLUES AND OTHER SOURCES OF HEAT, EXCEPT AT ALL ASSOCIATED WIRING AS SHOWN ON THE DRAWINGS AND AS LISTED FORWARDED TO THE OWNER OR HIS DESIGNEE FOR INCORPORATION IN EXAMINATION BEEN MADE, WILL NOT BE RECOGNIZED. 150 WATT LAMPS IN ALL AREAS THROUGHOUT THE SCOPE OF WORK CROSSINGS WHERE A MINIMUM OF TWO INCHES CLEARANCE SHALL BE IN THE FIXTURE SCHEDULE. THE ORIGINAL DRAWINGS AND/OR FUTURE USE. 1.1.7. TIME AND MANNER OF (EXECUTION OF WORK AREA. HELD. 2.9.2. FLUORESCENT FIXTURES SHALL BE PROVIDED WITH ELECTRONIC LAMP / 1.1.7.1. ALL WORK SHALL BIE DONE AS EXPEDITIOUSLY AS POSSIBLE AND IN BALLASTS AS MANUFACTURED BY G.E., UNIVERSAL, ADVANCE OR 3.2. TESTS AND INSPECTIONS 2.1.6. INSTALL, MAINTAIN, REPAIR, DISCONNECT, REMOVE AND/OR RELOCATE 2.4.22. JUNCTION BOXES OR PULL BOXES SHALL BE FURNISHED AND INSTALLED 3.2.1. ALL TESTS, AS MAY BE REQUIRED BY THE OWNER OR HIS DESIGNEE SUCH A MANNER A5 NOT TO CAUSE INTERFERENCE OR INTERRUPTION TEMPORARY LIGHT AND POWER SERVICE AS DESIGNATED BY THE TO AVOID EXCESSIVE RUNS OR BENDS BETWEEN OUTLETS AS HEREIN APPROVED EQUAL. RADIO FREQUENCY SUPPRESSION. OR LOCAL GOVERNING AGENCY, SHALL BE PERFORMED BY THIS TO THE BUSINESS OF THE TENANT OR OWNER. SUBMIT SCHEDULE CONSTRUCTION MANAGER. SPECIFIED. 2.9.3. ALL LINEAR FLUORESCENT LAMPS SHALL BE T8 (OCTRON) ENERGY CONTRACTOR. TESTS SHALL BE REPEATED AS REQUIRED WITH NO FOR REVIEW AND APPROVAL. THE SUBCONTRACTOR SHALL NOT 2.1.7, ENERGIZE, MAINTAIN AND REPAIR THE ENTIRE TEMPORARY LIGHT AND 2.5. HANGERS AND SUPPORTS SAVER BY GENERAL ELECTRIC, WESTINGHOUSE OR SYLVANIA. ADDITIONAL COSTS TO THE OWNER. OBSTRUCT ENTRANCES OR PASSAGES ON THE OWNER'S PREMISES. POWER SYSTEM CONTINUOUSLY DURING WORKING DAYS. UNTIL THE 2.5.1. PROVIDE SYSTEMS OF SUPPORTS FOR ALL CONDUIT, FIXTURES, AND 2.9.4. ALL LIGHTING FIXTURES, LAMPS AND BALLASTS SHALL MEET THE 3.2.2. TEST ALL THE WIRING SYSTEMS AND EQUIPMENT. PERFORM ALL TESTS ' 1.1.7.2. TRANSPORTATION OF MATERIAL INTO AND THROUGH THE BUILDING COMPLETION OF ALL CONSTRUCTION. EQUIPMENT COMPLETE WITH HANGERS, ANCHORAGE, SWAY BRACES, MINIMUM REQUIREMENTS AS SET FORTH IN THE GOVERNMENTAL ENERGY " REQUIRED BY LOCAL, STATE AND FEDERAL AUTHORITIES. PROVIDE ALL WILL BE SUBJECT TO REVIEW AND APPROVAL OF THE TENANT OR 2.1.8. THE CONTRACTOR SHALL NOT BE RESPONSIBLE FOR ANY COSTS "UNISTRUT" RODS, BOLTS, ANGLES, CHANNELS, PLATES, INSERTS, PRIME CONSERVATION CODE. LABOR, MATERIALS, APPLIANCES, EQUIPMENT, INSTRUMENTS, ELECTRICITY OWNER AND MAY BE LIMITED TO RESTRICTED TIMES OUTSIDE OF 1 2.9.5. ALL DIRECT FLUORESCENT LIGHTING SHALL BE PROVIDED WITH (sruz/ze ASSOCIATED WITH ENERGY CONSUMED FOR TEMPORARY ELECTRIC. COAT PAINTING, STENING, AND ALL OPERATIONS AND APPURTENANCES AND TRANSPORTATION AND ENGAGE, WHERE SPECIFIED, INDEPENDENT w nul NORMAL BUSINESS HOURS. 2.1.9. TEMPORARY ELECTRIC SHALL BE TAKEN FROM THE EXISTING BUILDING REQUIRED TO MAKE THE SUPPORTING SYSTEM COMPLETE IN ALL DIFFUSING MEDIA AS SPECIFIED ON DRAWINGS. TESTING LABORATORIES TO CONDUCT THE SPECIFIED TESTS. 1.1.7.3. THE SUBCONTRACTOR SHALL FURNISH AND INSTALL ALL NEW 2.9.6. COORDINATE CONSTRUCTION AND DESIGN OF TRIM AND SUPPORTS FOR MATERIALS AND SHALL REMOVE OR RELOCATE ALL MATERIALS AS DISTRIBUTION PANELS LOCATED ON THE SAME FLOOR AS THE AREA OF RESPECTS. ALL LIGHTING UNITS FOR CONFORMITY WITH CEILINGS SURFACES IN 3.2.3. WIRING SHALL TEST FREE OF SHORTS AND GROUNDS. NOTED ON THE DRAWINGS. BASED R OWNERS APPROVAL ALL WORK. 2.5.2. IT IS THE INTENT OF THIS SPECIFICATION THAT ALL HANGERS SHALL BE WHICH THE UNITS ARE INSTALLED. SUBMIT SUBSTITUTE TYPE FIXTURES 3.2.3.1. ALL RECEPTACLES SHALL BE TESTED WITH A CIRCUIT TESTER FOR 2.2. BALANCING AND GROUNDING SUPPORTED FROM BUILDING CONSTRUCTION. THE INTENT OF THIS PROPER GROUNDING AND POLARITY. EQUIP'T REMOVED SHALL BE DISPOSED OF BY THE SUBCONTRACTOR. 2.2.1. ALL BRANCH CIRCUITS SHALL BE BALANCED AT THEIR RESPECTIVE POWER SPECIFICATION IS TO PROVIDE SUPPORTS WHICH, IN EACH CASE, SHALL WI UNFORESEEN OBSTACLES, ETC., DICTATE WHICH SHALL BE DONE 3.2.3.2. ALL SWITCHES AND CONTROL WIRING SHALL BE TESTED TO INSURE 1.1.8. GUARANTEE PANEL TO WITHIN 10 PERCENT FULL LOAD APPLIED. NOT WEAKEN OR UNDULY STRESS THE BUILDING CONSTRUCTION. WITHOUT EXTRA COST TO THE OWNER. PROPER OPERATION. 1.1.8.1. ALL WORK SHALL BE GUARANTEED AGAINST DEFECTS FOR A PERIOD 2.2.2• ALL INSTALLED EQUIPMENT SHALL BE GROUNDED AS PER GOVERNING 2.5.2.1. HANGERS FOR THE WORK IN THE HUNG CEILING SHALL BE 2.9.7• EACH LIGHTING FIXTURE SHALL HAVE AN UNDERWRITERS AND 3.2.3.3. TESTS TO DEMONSTRATE THE CAPACITY SPECIFIED AND GENERAL OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE OF THE CODE I.E. N.E.C., N.Y.C.E.C. ETC... REQUIREMENTS AND AS INDICATED ON SUPPORTED FROM THE BUILDING STRUCTURE. MANUFACTURER'S LABEL AND SHALL COMPLY WITH THE REQUIREMENTS OPERATING CHARACTERISTICS OF ALL APPARATUS, SHALL BE A/C REPLACEMENT INSTALLATION AND ANY PORTIONS OF THE WORK WHICH DEVELOP THE DRAWINGS OR SPECIFIED HEREIN, AND SHALL INCLUDE, BUT NOT BE 2.5.3. PROVIDE ALL ANGLES, CHANNELS, PLATES, AND BOLTS OR OTHER OF ALL AUTHORITIES HAVING JURISDICTION. FIXTURES TO BE INSTALLED CONDUCTED IN THE PRESENCE OF, AND TO THE SATISFACTION OF, DEFECTS DURING THAT TIME SHALL BE REPLACED OR REPAIRED IN A LIMITED TO, THE FOLLOWING: STRUCTURAL SHAPES NECESSARY TO FASTEN CUNIDUT HANGERS TO THE IN NYC MUST BE MADE BY AN IBEW SHOP. THE OWNER OR HIS DESIGNEE. FOR CARRIER SWRM MANNER SATISFACTORY TO THE TENANT OR OWNER. 2.2.2.1. ELECTRICAL SERVICE. BUILDING CONSTRUCTION. 2.9.8. THE FINISH OF EXPOSED METAL PARTS AND STEM LENGTHS SHALL BE 3.2.3.4. WHERE IT IS IMPOSSIBLE TO TEST OUT WHOLE SYSTEMS AT ONE 1.1.9. PERMITS AND CERTIFICATES 2.2.2.2. CONDUITS AND OTHER CONDUCTOR ENCLOSURES. 2.5.4. HANGERS OR SUPPORTS SHALL BE BASED ON THE WEIGHT OF THE ITEM AS DIRECTED BY VERIZON. TIME, THEY MAY BE DIVIDED INTO PARTS AND EACH PART TESTED 1.1.9.1. GIVE NECESSARY NOTICES, FILE DRAWINGS AND SPECIFICATIONS WITH 2.2.2.3. NEUTRAL OR IDENTIFIED CONDUCTOR OF INTERIOR WIRING AND FOR CONDUIT OR RACEWAY WITH A MINIMUM CONCENTRATED LOAD 2.9.9• ALL LENSES, LOUVERS, OR OTHER LIGHT DIFFUSING ELEMENTS SHALL INDEPENDENTLY. THE DEPARTMENTS (HAVING JURISDICTION, OBTAIN PERMITS OR SYSTEM.(ONE POINT ONLY) OF 250 POUNDS AT THE CENTER OF THE SPAN BETWEEN SUPPORTS. BE REMOVABLE BUT POSITIVELY HELD IN PLACE SO THAT HINGING OR 3.2.3.5. ALL WIRING SHALL BE TESTED BY THE CONTRACTOR, AND LICENSES NECESSARY TO PERFORM THIS WORK, AND PAY ALL FEES 2,2.2.4. NON-CURRENT-CARRYING METAL PARTS OF FIXED EQUIPMENT SUCH 2.5.5. RIGID CONDUIT AND ELECTRICAL METALLIC TUBING (EMT) SHALL BE OTHER VIBRATION OR MOTION WILL NOT CAUSE THEM TO DROP OUT. WITNESSED AND APPROVED BY THE OWNER OR HIS DESIGNEE. THEREFORE. AS MOTORS, STARTER AND CONTROLLER CABINETS, INSTRUMENT SECURELY FASTENED WITHIN 3 FEET OF EACH OUTLET BOX, JUNCTION 2.9.10. ALL FIXTURES SHALL BE FURNISHED COMPLETE WITH NECESSARY 3.2.3.6. PROVIDE FOUR (4) COPIES OF ALL EQUIPMENT, OPERATING 31755 MAIN RD. 1.1.9.2. ARRANGE FOR INSPECTIONS AND TESTS OF ANY OR ALL PARTS OF CASINGS AND LIGHTING FIXTURES. BOX, DEVICE BOX, CABINET, CONDUIT BODY, OR OTHER CONDUIT DEVICES AND APPURTENANCES TO COMPLETELY INSTALL FIXTURES IN AND/OR MAINTENANCE MANUALS FOR SYSTEMS AND COMPONENTS THE WORK AS REQUIRED BY AUTHORITIES OR UTILITY COMPANIES 2.2.3. SPECIFIC GROUNDING REQUIREMENTS FOR THE PROPOSED EQUIPMENT TERMINATION. OPERATING CONDITION, INCLUDING ALL HANGING AND SUPPORTING INSTALLED. CUTCHOGUE, NY HAVING JURISDICTION AND PAY ALL FEES OR CHARGES FOR SAME. AREA SHALL BE AS SHOWN ON DRAWINGS 2.5.6. RIGID CONDUIT AND EMT SHALL BE SUPPORTED AT INTERVALS NOT DEVICES, PLASTER RINGS, STUDS, HICKEYS, CANOPIES, STEMS, CLAMPS, 3.3. CERTIFICATES AND GUARANTEES 1.1.10. LAWS AND ORDINANCES LEVELING DEVICES, GLASSWARE, ETC. GROUND FLOOR 2.2.4. GROUNDING SYSTEM SHALL BE FURNISHED AND INSTALLED IN EXCEEDING 10 FEET. 3.3.1. THE CONTRACTOR SHALL PROVIDE PROOF OF ELECTRICAL INSPECTION 1.1.10.1. INFORM THE TENANT OR OWNER OF ANY WORK OR MATERIALS WHICH ACCORDANCE WITH THE GROUNDING SPECIFICATIONS AND SHALL MEET 2.5.7. DIRECTION CHANGES - A HANGER OR SUPPORT SHALL BE INSTALLED 2.9.11. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL INTERMEDIATE SUPPORTS BY THE LOCAL ELECTRICAL INSPECTION AGENCY FOR ALL ELECTRICAL VIOLATES ANY OF THE APPLICABLE LAWS AND REGULATIONS BEFORE THE FOLLOWING GENERAL CRITERIA: CLOSE TO THE POINT OF A CHANGE IN DIRECTION OF ALL CONDUIT AS REQUIRED FOR THE INSTALLATION OF LIGHTING FIXTURES. FIXTURES TITLE: PROCEEDING WITH THE WORK. SHALL BE HUNG INDEPENDENTLY OF THE CEILING GRID. WORK TO THE OWNER OR HIS DESIGNEE AND PAY ALL ASSOCIATED 2.2.4.1. ALL GROUNDING CONNECTIONS SHALL BE MADE TO BRIGHTER RUNS, IN EITHER A HORIZONTAL OR VERTICAL PLAIN. FEES. 1.1.11. STANDARDS 210MOTORS AND MOTOR STARTERS SURFACES. APPLY CORROSION PROTECTION TO SURFACES EQUAL TO . .2.5.8. ALL HANGERS SHALL BE FABRICATED FROM STEEL AND ADJUSTABLE FOR 3.3.2. CONTRACTOR SHALL GUARANTEE AND SERVICE ALL WORK FOR A 1.1.11.1. MATERIALS SPECIFIED BY REFERENCE TO A SPECIFIC STANDARD SUCH "SCOTCHKOTE". ELEVATION. 2.10.1. WITH THE EXCEPTION OF SINGLE PHASE MOTOR THERMAL SWITCHES, PERIOD OF ONE (1) YEAR FROM THE DATE OF ACCEPTANCE. SPECIFICATIONS AS THE AMERICAN SOCIETY OF TESTING MATERIALS, UNDERWRITERS 2,2.4.2. ALL GROUNDING CONDUCTOR TAGS SHALL BE FIBER OR METAL ALL STARTERS SHALL BE FURNISHED BY OTHER DIVISIONS AND LABORATORIES, AMERICAN NATIONAL STANDARDS INSTITUTE, FEDERAL CONSTRUCTION. DELIVERED TO THE ELECTRICAL CONTRACTOR FOR INSTALLATION. SPECIFICATIONS, A TRADE ASSOCIATION STANDARD, OR OTHER SIMILAR 2.2.4.3. PROVIDE CONDUIT & SLEEVES FOR GROUND WIRE PROTECTION WHERE 2.10.2. ALL MOTORS SHALL BE FURNISHED AND SET UNDER OTHER DIVISIONS. STANDARD SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST SHOWN ON DRAWINGS AND/OR SPECIFICATIONS. 2.10.3. A THERMAL OVERLOAD CUTOUT SWITCH WITH INDICATING LIGHT SHALL REVISION THEREOF IN EFFECT AT THE TIME OF BIDDING, EXCEPT AS BE PROVIDED FOR ALL EXHAUST FANS WHERE PROTECTION IS NOT DATE: 8/16/17 LIMITED BY TYPE, CLASS OR GRADE, OR MODIFIED IN SUCH2.2,4.4. PROVIDE "DO NOT DISCONNECT" TAGS ON ALL GROUNDED PROVIDED AS PART OF THE EQUIPMENT. PROJECT NO: 17-2165 REFERENCE. CONNECTIONS. 2.10.4. UNLESS INDICATED ELSEWHERE HEREIN OR ON THE DRAWINGS ALL CONTROL DEVICES FURNISHED BY OTHER CONTRACTORS SHALL BE DRAWN BY: LAS 1.1.11.2. ALL MATERIALS, EQUIPMENT AND APPARATUS SHALL BE ELECTRICAL 2.2.4.5. "STAR" WASHERS SHALL BE USED AS LOCKING WASHERS ON GROUND INSTALLED UNDER THIS CONTRACT, ALONG WITH ALL CONTROL WIRING TESTING LABORATORIIES OR UNDERWRITERS' LABORATORIES LISTED OR LUG BOLTS AND ALL OTHER GROUND CONNECTIONS. TO SAME. THIS SHALL INCLUDE MOTORIZED DAMPERS, INSTRUMENT CHECKED BY: KJH / PEJ LABELED FOR ALL ITEMS WHERE SUCH LISTING OR LABELING IS 2.2.5. A SEPARATE GROUND WIRE SHALL BE RUN IN EACH CONDUIT. EVERY PANELS, ELECTRICALLY CONTROLLED VALVES, FREEZESTATS, ETC. AVAILABLE. ITEMS WHICH ARE NOT LISTED OR LABELED WILL NOT BE CONDUIT SHALL HAVE A BONDING BUSHING INSTALLED AND IT SHALL BE 2.10.5. THE WORK OF THIS DIVISION SHALL INCLUDE: SCALE: NONE ACCEPTED IF LISTED' OR LABELED EQUIPMENT CAN BE OBTAINED BONDED TO THE ENCLOSURE AND TO ALL OTHER CONDUIT BUSHINGS 2.10.5.1.1. POWER FEEDER FOR CONTROL WIRING TO A SINGLE POINT. DRAWING NO: FROM ANOTHER ACCEPTABLE MANUFACTURER. EACH COMPONENT OF ENTERING THAT ENCLOSURE. 2.10.5.1.2. INSTALLATION OF MOTOR STARTERS. 2.10.5.1.3. POWER FEEDERS TO STARTERS AND MOTOR BRANCH CIRCUITS. IMM A"L�Mm601 e00- 1 SPECIFICATIONS SCAM MOrE SHEET NO: 5 of 5