Loading...
HomeMy WebLinkAbout42007-Z �p Town of Southold 12/11/2018 P.O.Box 1179 53095 Main Rd Southold,New York 11971 N Z—?,V CERTIFICATE OF OCCUPANCY No: 40094 Date: 12/11/2018 THIS CERTIFIES that the building BARN Location of Property: 1605 Mill Path, Southold SCTM#: 473889 Sec/Block/Lot: 56.-1-4.2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/18/2017 pursuant to which Building Permit No. 42007 dated 9/28/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ACCESSORY BARN AS APPLIED FOR The certificate is issued to Carter, Scott of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 42007 12-07-2018 PLUMBERS CERTIFICATION DATED A th 0 d Signature TOWN OF SOUTHOLD gUFFO(,� BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY �y St's v ttt BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 42007 Date: 9/28/2017 Permission is hereby granted to: Carter, Scott 61339 Route 25 Southold, NY 11971 To: construct accessory barn as applied for per DEC & Trustee Non-Jurisdiction letters. At premises located at: 1605 Mill Path, Southold SCTM # 473889 Sec/Block/Lot# 56.-1-4.2 Pursuant to application dated 9/18/2017 and approved by the Building Inspector. To expire on 3/30/2019. Fees: CO -ACCESSORY BUILDING $50.00 ACCESSORY $612.00 Total: $662.00 Bu _ spector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy -$.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial $15.00 Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: �j'��15 A✓,'6 2. �q 4✓.`NGLd House No. ,, /� Street Hamlet Owner or Owners of Property: 4 -lee,-' '&II.-Ir Suffolk County Tax Map No 1000, Section Block Lot 191z- Subdivision Filed Map. Lot: Permit No.—gQan Date of Permit. Applicant: Health Dept. Approval- Underwriters Approval: Planning Board Approval- / Request for: Temporary Certificate Final Certificate- y (check one) Fee Submitted S Applican ignature oF so�ryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road N Fax(631)765-9502 P.O. ox 117 Southoldd,,NY 119711-0959 �Q roper Achert(a-town.southold.ny.us Q l�C"UNT1)�c� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To. Scott Carter Address. 1605 Mill Path City Southold St: New York Zip 11971 Building Permit#• 42007 Section. 56 Block: 1 Lot: 4.2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor, home owner DBA: License No SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor 1st Floor X Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 1 Ceiling Fixtures 4 HID Fixtures Service 3 ph Hot Water GFCI Recpt 3 Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel 60a A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches 3 Twist Lock F1 Exit Fixtures TVSS Other Equipment: "HORSE BARN" Notes: t _ Inspector Signature: �� Date: December 7 2018 r 81-Cert Electrical Compliance Form.xls �o�yoF souryo� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ FOUNDATION 1ST [ ] ROUGH PLEIG. �irv�✓ [ ] FOUNDATION 2ND [ ] INSULATION FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: [)� oor L-v ' v DATE INSPECTOR Nur • of SOUryy6 # # TOWN OF SOUTHOLD BUILDING DEPT. e 765-1802 z � INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: 475,f4(Z-c- DATE INSPECTOR pF SOUlyO6 * TOWN OF SOUTHOLD BUILDING DEPT. °`�rou�nr 765-1802 INSPECTION 7 [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: o l� DATE �� INSPECTOR ' OF SOUTyo6 # # TOWN OF SOUTHOLD BUILDING DEPT. °��ovxn 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2NDXFINAL SULATION FRAMING / STRAPPING [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: 0 c UTI\ t V" AAA "9 /povo- DATE INSPECTOR FIELD INSPECTION REPORT DATE CO EN FOUNDATION (1ST) � y -------------------------------------- FOUNDATION (2ND) IN Ma z • o V) ROUGH FRAMING& y l PLUMBING A r INSULATION PER N. Y. H STATE ENERGY CODE C r r-- .L1. All$ FINAL ADDITIONAL COMMENTS 9 et&ff(o 6-- 6 � :* �J � rr � z d TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502Survey SoutholdTown.NorthFork.net PERMIT NO. , Check_ Septic Form N.Y.S.D.E.C. Trustees C.O.Application_ Flood Permit Examined 20Single&Separate_ Storm-Water Assessment Form Contact: ��� Approved 20A Mail to: 416/r 4ef64-- Disapproved a/c e2ki'o 10 Phone: 76� If9y Expirati n DgkliinslKspector SEP 1 8 2017 APPLICATION FOR BUILDING PERMIT / MUD INGDEPT. Date � —� 20 17 TOWN OF SOUTHOLD INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shal I be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature o pplicant or name, if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises `-1/1-d17- (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: IOJ- 111Z4 /�Y7N QyozzYaze House Number Street Hamlet County Tax Map No. 1000 Section 477 Block / Lot Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy /� n b. Intended use and occupancy Zjve /��rVAGC°` ''" 3. Nature of work(check which applicable): New Building Jr Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost ����/, � Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories r Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of tories�T _ 8. Dimensions of entire new construction: Front Rear Depth Height // Number of Stories f 9. Size of lot: Front ,old Rear .T%�� Depth 10. Date of Purchase / 6f-� Name of Former Owner 77 Name P .ee&Ly 11. Zone or use district in which premises are situated eC, e O /1312. Does proposed construction violate any zoning law, ordinance or regulation? YES NO—/- 13. . Will lot be re-graded? YES k NO Will excess fill be removed from premises? YES NO)( 14. Names of Owner of premises 4'# 'Z/A/E e4-1-e4- Address V✓-'11G'0 IY Phone No. / 71l Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES_No * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MA*t_L,REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) S: COUNTY 0&" 45C'o P,� �� being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn tp before me t -j'-� day of 201- 2 0 - L.DWYER n4f .R otary Public NOTARY PUBLIC,STATE OF NEWYORK Signat e of Applicant NO.01DW63069 QUALIFIED IN SUFFOLK COUNTY Q\ ^,V COMMISSION EXPIRES JUNE 30,2[1 1 r John M.Bredenneyer III,President �� S�UjyO Town Hall Annex Michael J.Domino,Vice-President �® 1p 54375 Route 25 P.O.Boa Glenn Goldsmith l�S Southold,New York 11971 A.Nicholas Krupaki G Q � O Telephone(631)765-1892 Charles J.Sanders ��yC � � Fax(631)765-6641 ®Uld"i`t, BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD September 19, 2016 Mr.and Mrs. Scott Carter 61339 Route 25 Southold, NY 11971 RE: 61339 ROUTE 25, SOUTHOLD SCTM#: 1000-56-1-4.2 Dear Mr. and Mrs. Carter: The Southold Town Board of Trustees reviewed the letter and project plan which you submitted on September 16, 2016 and determined that the proposed construction of two pole bams are out of the Wetland jurisdiction under Chapter 275 of the Town Wetland Code and Chapter 111 of the Town Code.` Therefore, in accordance with the current Wetlands Code (Chapter 275) and the Coastal Erosion Hazard Area (Chapter 111) no permit is required. Please be advised, however, that no construction, sedimentation, or disturbance of any meward of the tidal and/orfreshwater wetly do jur d t d0r�r or seawaird of-the coastal-erosion hazard area as indicated above, orwithiii, 100 landward from the top of the bluff, without further authorization from the Southold M; Town Board of Trustees pursuant to Chapter 275 and/or Chapter 111 of the Town Code. It is your responsibility to ensure that all necessary precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Tidal Wetlands jurisdiction and Coastal Erosion Hazard Area, which may result from your project. Such precautions may include maintaining adequate work area between the tidal wetland jurisdictional boundary and the coastal erosion hazard area and your project or erecting a temporary fence, barrier, or hay bale berm. t A 2 This determination is not a determination from any other agency. If you have any further questions, please do not hesitate to call. Sincerely, Michael J. Domino, Vice- President Board of Trustees MJD:dd New York State Department of Environmental Conservation Division of Environmental Permits, Region 1 SUNY @ Stony Brook 50 Circle Road, Stony Brook, NY 11790-3409 Phone: (631)444-0365•Fax: (631)444-0360 Website:www.der.ny.gov LETTER OF NO JURISDICTION April 13, 2016 Mr. Scott Carter 61339 Route 25 Southold, NY 11971 Re: Carter Property 61339 Route 25, Southold, NY SCTM# 1000-56-1-4.2 Application#1-4736-03096/00003 Dear Applicant : Based on the information you submitted, the Department of Environmental Conservation has determined that your project to construct(2) barns as shown on the plans by Scott Carter, dated X21116, Is more than 100 feet from regulated freshwater wetlands. Therefore, no permit is required pursuant to the Freshwater Wetlands Act(Article 24) and its implementing regulations(6NYCRR Part 663). Please be advised, all construction, clearing, and/or ground disturbance must remain more than 100 feet from the freshwater wetland boundary. In addition, any changes, modifications or additional work to the project as described, may require DEC authorization. Please contact this office if such activities are contemplated. This letter shall remain valid unless site conditions change. Please note that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies or local municipalities. Sincely, J n A. i la erm' rator cc: BOH; File ` f SIF(0)IR IR Scott A. Russe ��l[\SVA\`�C )E�E� Russell % telN \(G]EIMI EN T SUPERVISOR � � � ,,� 1 .� I�ul[A\1�A SOUTHOLDTOtNN HALL-P-O-Box 11794] 0 f Town of Southold t.* 53095 Main Road-SOUTHOLD.NEW YORK 11971 .y CHAPTER 236 - STORMWATER MANAGEMENT 'WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT INVOLVE ANY OF THE FOLLOWING: (CHECK ALL THAT APPLY) Yes No ❑ A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑U B. Excavation or f illing involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑ ] C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑ D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area_ i F1 El E. Site preparation within the one floodplain as depicted - - - ---=en-F-1RM-Map-ef- ❑ F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces- _. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with Your Building Permit Application. S.C.T.M. a: 1000 Dat` APPLICANT: (Property Owner,Design Professional,Agent,Contractor,Other) / District NAME QVC 617 IX rPrNa Section Block Lot r :' hC)B B�'iLDI\fes LPaNTN ENT l >E OtiL Contact Inforrrutiore fir- ��� 7aronc,u.nn.-r Reviewed By: _ C� (y Date: Property Address / Location of Construction Work: — — — — — — — — — — — — — — — ❑ Approved for processing Building Permit. [ .Oywy _ — — Sto water Management Control Plan Not Required 1117/ Stormwater Management Control Plan is Required (Forward to Engineering Department for Review.) f-ORM ` SMCP - TOS MAY 2014 APPLICANT &C.T.M. 1000 CHAPTER 236 Wroperry Owner, Design Professional,Agent,Contractor,Other) ---p,,-�— b0 117 110�1�Y ,r! f!z Stormwater Management Control Plan CHECK LIST , NAME. Cv'7 —Section Block Lot z S M C P -Plan Requirements: Provide ONE copy of the Building Permit Application. P� �,�� �`rYy Date: bio * The applicant must provide a Complete Explanation and/or Reason for not providing H _ f/7 1 all information that has been Required by the following Checklial I A Site Plan drawn to scale Not Less that 60' to the inch MUST YES NO NA If You answered No or NA to any Item, Please Provide Justification Herel show all of the following items: If you need additional room for explanations, Please Pra a Location & Description of Property Boundaries b Total Site Acreage. =E c Existing - Natural & Man Made Features within 500 L.P. EROSIO N:FCorg �) of the Site Boundary as required by §236•1702). Shall includp he it not bLf(OLS d Test Hole Data Indicating Soil Characteristics&Depth to Ground Water, A well m fil"Ifa to: ron Entrance PT' e Limits of Clearing & Area of Proposed Land Disturbance, FIN Wire Ba HOL: f. Existing & Proposed Contours of the Site (Minimum z intervals) SeedinmciligStabilization & ft g Location of all existing & proposed structures, roads, Pesed rinactive soils. driveways, sidewalks, drainage improvements & utilities, h Spot Grades & Finish Floor Elevations for all existing & proposed structures. I Location of proposed Swimming Pool and discharge ring. 74;7&—y1f'11i xwL J. Location of proposed Soil Stockpile Areas). e'c'.' nidi sots EkGot�.6i�'� �T,v �s/v .�"6:L ✓�DG�'lojcE k Location of proposed Construction Entrance/Staging Area(s). I Location of proposed concrete washout area(s), d �'v,✓T ✓v�r�f aCo Cert' F���`i.✓G m Location of all proposed erosion&sediment control measures. I 2. Stormwater Management Control Plan must include Calculations showing that the stormwater Improvements are slzed to capture,store,and Infiltrate i on-site the run-off from all impervious surfaces generated by a two(21 inch rainfall / storm event PECTION 3 Details 8 Sectional Drawings for Stormwater practices are required for approval. Engineer) SatItems requiring details shall include but not be limited to: ' -011at E before o Erosion & Sedil7tem Controls, a rains een a ion b Construction Entrance & Site Access. to Code. _ c Inlet Drainage Structures (e.g,catch basins,trench drains,etc.) d Leachinq Structures (e. . Infiltration basins,swales,etc.) - I OR t I. ;�3C'heckList P A � -1' SE ONLY ❑ Additional Information is Required. Reviewed & Stormwater Management Control Plan is Not Complete Approved By — — — — — — — — — — — — — — — — — — — — — — — — - i Stormwater Management Control Plan is Complete Dote7 17 ! I SMCP has been approved by the Engineering Department . t FORM " SWCS MAY 2014 Of SO�r�ol o ' Town Hall Annex J [ J [ Telephone(631)765-1802 54375 Main Road cn ax(631)765995a2 -ownoold .ny usP.0.Box 1179 t Southold,NY 11971-0959 YO Iy�IIUHT'1,Nc� BUH DING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY. Date: Company Name: - 1- Name: csrr � U is License No.: Address: 6/.T.79 oars 2 IWI Phone No.: 6,T/ ��,� 0,Y/y JOBSITE INFORMATION: (*Indicates required information) *Name: *Address: /.��� 2 t%vT,vG� i✓. 7, *Cross *Cross Street: Niiv *Phone No.: ?/-7Gr' y9y Permit No.: 1�7 Tax-Map District: 1000 Section: S"6. Block: / Lot: f,, Z *BRIEF DESCRIPTION OF WORK(Please Print Clearly) fE (Please Circle All That Apply) *Is job ready for inspection: ��' NO ough:In> Final *Do-you need a Temp Certificate: YES fZP Temp Information (if-needed) f *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect. Underground Number of Meters Change of Service Overhead t Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form \ . FOCK G�� Town Hall Annex �� y� .� Telephone(631-1802 54375 Main Road Fax(631) 734-9502 — P. O Box 1179 oN z Southold, NY 11971-0959 BUILDING DEPARTMENT NOTICE OF UTILIZATION OF TRUSS TYPE CONSTRUCTION, PRE-ENGINEERED WOOD CONSTRUCTION AND/OR TIMBER CONSTRUCTION Date: Owner. Li tion of Property: Plea a take notice that the (check applicable line): New'rQg1dQn#a1 structure Addition to existing residential strucfttre ; :x Rehabilitation to an existing residential structure to b constructedflf performed at the.subject prpperty referpttce above will LAilize (ch applicable line): Truss type construction (TT) Pre-engineered wood construction{PW) Timber construction (TC} in the following iocation(s)(check applicable line): Floor framing, including girders and beams (F) Roof framing (R) Floor and roof flaming (FR) Signature: C Cel Name (person submitting this form): Capacity(check applicable line): Owner I Owner representative { issResRegl5.docx Effective 7!7.2015 ! ( Q °� {'ropesPd •� C lid N A r CO r 'mac, Z' 1 � t �...! `...J' 'tet i ! �C'"..+. •,.f a"`"~��.. .. - - •"� r . t,.- . ...y..t r ir\VIE A A 7• %5uplrOL4 CO. i � 1 h , + o v ` � �uarorrtee�' to as a vr•veyed r,,Oc. 2/, 1994 ail JR04EID AS NO ED � DIY Pole Barns &Supplies DRAT AGE INSPECTIONS ARE REQUIRED( �� 9232 Hogpath Road Arcanum, OH 45304 Cont ct TOS Engineering at 765-1B.P.#� Li 560 befor; POLE BARNS Business: 937-547-9100 Fax: 937-547-9122 Bac III,OR Provide Engineer's Certification � ' that t e drainage has been Installed to Code. cc-' � BY:�.... h_',-, 6t;. DEP, -rd&KAT 765-;602 8 AM TO 4 PM FOR THE BuildingSpecifications FOLIC,'NG irvS^C-C T IGNS: 1. TWO REQUIRED ELECTRICAL FOR POURED r nNCRETE Building Width 32' Truss Loading 20-5-0-5 psf INSPECTION REQUIRED 2. ROU 3H - F'-' ' ; d, PLUMBING Building Length 40' Ground Snow Load 20 psf 3. INSULAT Building Height 8' Wind Speed 130 mph Vult', 91 mph Vasil 4. FINAL 1 MUSTExp C, H=15' Eave Overhang 12 in. Code. IBC 2015 TRUSS PL.ACARDING REQUIRED BE CClvi. , C.L`, ALL CCNS SHALL MEET THE Gable Overhang 12 in. Risk Category 11 RLQUIREMEP . Of:THE CODES OF NEW Pitch of Roof 6 in./12 Soil Pressure = 1500 psf YORK STATE. NOT RESPONSIBLE FOR Style of Building Post Frame All exterior lighting DESIGN OR CONSTRUCTION ERRORS. installed,replaced or Customer Name Scott Carter repaired shall conform COMPLY WITH ALL CODES OF Customer Address 61339 Route 25 Southold, NY 11971 to Chapter 172 NEW YORK STATE & TOWN CODS Customer Phone Call 631-765-4944 of the Town Code AS REQUIRED AND CONDITIONS OF S6tffH9E8 0*28A-- SDUMOL07OV WMWTEES powered by Symun Systems,Inc. www.symun.com WTPTF-- Trusses shall be installed and braced in accordance with BCSI-10 f.F F1 OCCUPANCY OR I Note:The reports,elevations,diagrams,and drawings included in this estimate are not architectural blueprints. The builder is responsible for structural integrity,proper usage of materials,and adhenng to local building codes. Always be sure to verity the materials and drawing packet with your local building inspector,engineer,or architect Every effort has been made to create accurate and detailed drawings and reports. However,due to the number of combinations of materials that can be used,there exists the possibility for errors This packet is an estimate and should be reviewed by the builder before starting the project Symun Systems,Inc accepts no responsibility for engineering,building codes violations,or the structural integrity of the building. i ^T E� �915b0 a'��FfSSIONP�' P.E. Robbins, P.E.1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/2017 Page 1 of 24 DIY LC LISiL LLI:ilV IL Maestro® POLE BARNS QT NFw ��� Ros�ro�,� MID P.E. Robbins,P.E. 1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/2017 Page 2 of 24 , � C�aero!ctie u ox I y Maestro® POLE BARNS �o•�� � w fi `PFS 093581;5 pqa . SS10NP� P.E. Robbins,P.E. 1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/2017 Page 3 of 24 L L LULL LLC'ULL tt NORTH SIDE-EAVE SIDE 2 ELEVATION Maestro [cl,mating SQfnva rr. POLE BARNS 0 ti OF NEw.1- NEW * w -- `JFO 0935 AR�fiES SIONP� P.E. Robbins,P.E. 1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/2017 Page 4 of 24 C,Cl LLHtL LCCIC Ll SOUTH SIDE—EAVE SIDE 1 ELEVATION Maestro F�lm.,at.9sos—v P O L E B A R N S "°'°B.'—.a—q—9 Uo« of NEw y ti.RIO y� u, 0935% ROfifSS10N�' P.E.Robbins, P.E. 1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/2017 Page 5 of 24 L L LlSU LLCUU tl WEST SIDE-GABLE SIDE 2 ELEVATION Maestrd Estimating Sothw POLE BARNS Pott&erns,Garagos 8 0-ks � f �I i 1 ' of- NEW k Co,,�Q. w 9350 R�FfSSlON�' P.E. Robbins,P.E. 1777 State Rt 167 Victoria,IL 61485 PER171458 09/12/2017 Page 6 of 24 L L LISAI LL OCILl IT EAST SIDE-GABLE SIDE 1 ELEVATION Maestrd Estimating Saftwarc POLEBARNS Poaa Linrnz,Garagos!1 Danks .�of Wwj, 000 9� � tiN W F 093 5 FES SIO��v P.E. Robbins,P.E. 1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/2017 Page 7 of 24 POLE LAYOUT Residential Use.1280 sq.ft. Maestro' LJ i ii POLE BARNS Eave 1 —91101/2' 10, 91101/2- 4/0 X 3/0 WINDOW OPENING 4/0 X 3/0 WINDOW OPENING 4/0 X 3/0 WINDOW OPENING 4/0 X 3/0 WINDOW OPENING 112 ;o C4 Diagonal: Z�72 t 2 Z, x FF : O 50'10 1/2" ;c ill 4/0 X 3/0 WINDOW OPENING 4/0 X 3/0 WINDOW OPENING 4/0 X 3/0 WINDOW OPENING 3/0 DOOR OPENING 9'10 1/2" —10, T9 3/4" T2 1/4" —1 ()F NE T 2'101/2" 8—VBPost Atbxh Eka W CO Eave 2 Girt&Posh w/(2)16D Gaiv Nads @ Each TYP 39'9' P.E. Robbins, P.E. 1777 State Rt 167 Victoria, 161485 PER171458 09/12/2017 Page 8 of 24 DIY POLE BARNS Footing I Skirtboard Detail Structural Post Attach Metal to Skirtboard w/ 1-1/2"Screws I I Rat Guard/Base Angle Pressure Treated Skirtboard I I I . . . . . . . . . . . . . . . . . . . .L . . j I I J I I I I I I I ' I 1 I 1 Hole Size:18"Diameter(Typ.) I I I I 0 12" 0 I I I I 48"Typ. I I I I I I I I Structural Past I I I I I I I I I 15"x 4"Pre Cast Concrete of NEW I I FO°ter 8"X 26"Gravel ,• 2 x 6 Post Cleat I Cleat aAached with(4)16d I Nails t C T - s•` 0935tq "VOFfSS10 P.E. Robbins,P.E. 1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/2017 Page 9 of 24 I I I I I I Graber Post G-Rib#1 I Steel Roofing 1/4 in x 72 in z 125 I R insulation I I I I I I Roof Edge Facia Board Trusses Attached to Came w/ Facia Cover, Simpson H2 5A Rafter Tie(or / 2 x 10#1 equiv) nm/ Attached h (5)40D Nails fi at Each Location 2x10#15YP t2 in Attached With (5)40D Nails at Each Location 4 5 x 5 5 laminated Columns 3 Ply I I r+ 1 0935bO p'��FfSS10NP� P.E. Robbins. P E. 1777 State Rt 167 Victoria, IL 61485 PER 171458 09/12/2017 Page 10 of 24 GABLE2 CROSS SECTION I 6/12 PITCH TRUSS SYSTEM WITH A NON-STANDARD HEEL (HEEL HEIGHT: 0-6-8 OR 6 1/2 IN.) TRUSS SPACING:48 IN.O.C. ROOF LAYER 1: FOIL/SINGLE BUBBLE/POLY-ROLL 1/4 TRUSS LOADING INFORMATION:TCLL/TCDL/BCLL/BCDL IN X 72 IN X 125 FT 25-5-0-5 ROOF LAYER 2: BURNISHED SLATE G-RIB#1 STEEL TOTAL TRUSS LOADING=35 P.S.F. PANEL BRACE PER TRUSS MANUFACTURER'S RECOMMENDATIONS 20 9/16 in PURLINS:2 X 4 CONSTRUCTION GRADE FASTENED LAYING FLAT SUB FACIA:2 X 6 CONSTRUCTION GRADE FACIA COVERING:CLAY STEEL 1 1/2 IN.X 5 1/2 IN. 24 in. 96 in. ANGLE 6 X 10 FT 0 IN UNDEREAVE:CLAY SOLID G-RIB 36 IN X 1 FT 0 IN 92 in. 90 in. 24 in. INTERIOR FINISHED FLOOR HT.WILL BE 4 in.BELOW CORNER POSTS: LAMINATED COLUMNS 3 PLY 4.5 X 5.5 THE TOP OF THE SKIRT BOARD INTERMEDIATE POSTS:LAMINATED COLUMNS 3 PLY 4.5 4 IN.CONCRETE FLOOR W/STRUCTURAL STRENGTH- X 5.5 SPACING 10 FT O.C. 23 7/16 in. 3500 P.S.I. EXTERIOR CARRIER:CONSTRUCTION GRADE 2 X 10 /_ UNDISTURBED SOIL OR COMPACTED SAND FILL INTERIOR CARRIER:CONSTRUCTION GRADE 2 X 10BACKFILL HOLE WITH SAND/GRAVEL FILL&COMPACT EXTERIOR WALL GIRTS:CONSTRUCTION GRADE 2 X 4 ti PIER FOOTING: PRECAST 5000 P.S.I. 15 IN.X WIDE 4 WALL LAYER 1:DARK RED G-RIB#1 STEEL PANEL ?' r} I IN.THICK CONCRETE PAD OVER 26 IN.WIDE X 8 IN. 1 I THICK COMPACTED GRAVEL EXTERIOR SKIRT BOARD:TREATED 2 X 8 ;.rti rti. it }rti. i DIY DOES NOT PROVIDE CONCRETE FLOOR. SIDING BEGINS 2 5/8 IN.BELOW THE TOP OF 1;: ti?ti; I SOIL BEARING PRESSURE IS ASSUMED. SKIRT BOARD 48 in. . : {?{.:. . . . I POST CLEATS:TREATED 2 X 6 ON EACH SIDE OF POST ?tiI STARTING 6 IN.ABOVE THE FOOTING EARTH GRADE BEGINS 7 IN.BELOW THE TOP OF SKIRT }r; }r} • ' • • • .I BOARD . . 4 in. • •.i tpF NEW 15 in. ���V Q 1~.Ft �0- 8" X 26" Gravel w 09 3 5t c�`Z AR��fSS10N�� P.E. Robbins,P.E 1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/2017 Page 11 of 24 GABLE 1 CROSS SECTION I 6/12 PITCH TRUSS SYSTEM WITH A NON-STANDARD HEEL (HEEL HEIGHT: 0-6-8 OR 6 1/2 IN.) TRUSS SPACING:48 IN.O.C. ROOF LAYER 1:FOIL/SINGLE BUBBLE/POLY-ROLL 1/4 TRUSS LOADING INFORMATION:TCLL/TCDL/BCLL/BCDL IN X 72 IN X 125 FT 25-5-0-5 ROOF LAYER 2:BURNISHED SLATE G-RIB#1 STEEL TOTAL TRUSS LOADING=35 P.S.F. PAN EL BRACE PER TRUSS MANUFACTURER'S RECOMMENDATIONS 20 9/16 in. PURLINS: 2 X 4 CONSTRUCTION GRADE FASTENED / LAYING FLAT SUB FACIA:2 X 6 CONSTRUCTION GRADE FACIA COVERING:CLAY STEEL 1 1/2 IN.X 5 1/2 IN. 24 in. 96 in. ANGLE 6 X 10 FT 0 IN UNDEREAVE:CLAY SOLID G-RIB 36 IN X 1 FT 0 IN 9 90 in. 2 in. 24 in. INTERIOR FINISHED FLOOR HT.WILL BE 4 in.BELOW CORNER POSTS:LAMINATED COLUMNS 3 PLY 4.5 X 5.5 THE TOP OF THE SKIRT BOARD INTERMEDIATE POSTS:LAMINATED COLUMNS 3 PLY 4.5 f- 4 IN.CONCRETE FLOOR W/STRUCTURAL STRENGTH- X 5.5 SPACING 10 FT O.C. 23 7/16 in. 3500 P.S.I. EXTERIOR CARRIER:CONSTRUCTION GRADE 2 X 10 UNDISTURBED SOIL OR COMPACTED SAND FILL INTERIOR CARRIER:CONSTRUCTION GRADE 2 X 10BACKFILL HOLE WITH SAND/GRAVEL FILL&COMPACT EXTERIOR WALL GIRTS:CONSTRUCTION GRADE 2 X 4 ti PIER FOOTING:PRECAST 5000 P.S.I. 15 IN.X WIDE 4 WALL LAYER 1:DARK RED G-RIB#1 STEEL PANEL er: }i}' I IN.THICK CONCRETE PAD OVER 26 IN.WIDE X 8 IN. THICK COMPACTED GRAVEL ti•L ti•L EXTERIOR SKIRT BOARD:TREATED 2 X 8 tifti tirti I }f {f; i DIY DOES NOT PROVIDE CONCRETE FLOOR. SIDING BEGINS 2 5/8 IN.BELOW THE TOP OF ti?ti tiff; . ..I SOIL BEARING PRESSURE IS ASSUMED. SKIRT BOARD 48 in. tirti {{. I POST CLEATS:TREATED 2 X 6 ON EACH SIDE OF POST ti? ?ti I STARTING 6 IN.ABOVE THE FOOTING EARTH GRADE BEGINS 7 IN.BELOW THE TOP OF SKIRT }rti }}} . . BOARD 4 in. !�'°f NEW y 15 in. �Q' Q E•f3Q Q,9 8" X 26" Gravel Gj ` yN .Q 0915a� A�FfSS10N�' P.E. Robbins,P.E. 1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/2017 Page 12 of 24 Truss Block Detail Truss 4'0/C Structural Post Truss Carrier (5) 16D nails 2x 10 SYP#1 or 9 1/2 LVL 101 0 o ;0i 0 0 Eave View ` 0 0 0 ;7,E 1 z 1 01 0 0 16 D Nail(6) Three Per Side (5)40D nails At Posts Overhead Structural 2 X 6(TYP.) View Post Truss Block (5)40 D Ring Shank Nail 0� NSW per 2 X 10 E Rp �0 Truss Carrier cn W Truss 4'O/C d• `F� 0935ba S SION�� P.E. Robbins,P.E. 1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/201 Page 13 of 24 t 2x10 Nailing Pattern Nailing Pattern Truss Carrier 2x10 SYP N1 or 9 1/2 LVL Truss Carrier ° o o ° Use 40D Gal Pole Barn Nails 5 2 x 10 ° ° — ° o Per Post each side and 6 at SYP 81 or 9 1/2 LVL each splice AL Wall Girt T-Wall Girt Detail 2x 4 - - - - - - Construction Grade --_.— — � 2X4naded to the girt and structural post Wall Girt - 2x4 - Construction Grade structural post 1.1_. Skint Board I nstructbn Grade 2%4 wall girt and structural post _. Nail 2x4 flat girt to 2x4 Sort Board - -. - - - -- edge girt with .131" x 3" Construction Grade2 8 nails at 6" c/c. Toe-nail Orr NEwr Ar shelf girt to column with (2) .131° x 3" nails each Nom: end. N Nailing pattern for 2x4 wall girts is the same as r� W nailing patter for 20 purlins �+ With 16D nails p'��FES SIONp� P.E. Robbins,P.E. 1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/2017 Page 14 of 24 ' NORTH SIDE-EAVE SIDE 2 TRUSS AND PURLIN LAYOUT CU IIALL dlUtt uly Maestro' Estimating Software POLEBARNS Pelle Barns,Garages tL Decks FACIA Construction --- ------------- --------- ------------ - ------------- --- ----- - - - ------- Grade 20' ... 20' 16' 2 x 6 S 20' o - s � N 20' 20' S N 16 20 20' N 2p' 20' S 1 + N S i 20' i20' i0 lV \ 18' 20' r 20' 16' 18' N S 20' 20' lV 20' 20' - - S PURLIN Construction V Grade 2 x 4 F. 16 20' 20' N 7 � 31F NEh,,20' 77:k ��� `ff G rrlp0�� FACIA Bottom Edge of * ``/j` Purlin is 3 4"In Construction / Grade from Tail of Truss Cs` 2 x 6 5i 09350 SS10Na~ P.E. Robbins, P.E. 1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/2017 Page 15 of 24 SOUTH SIDE-EAVE SIDE 1 TRUSS AND PURLIN LAYOUT Maestro' -wl Estimating software POLE BARNS PoW Barns,Garages I Docks FACIA Construction ___ _____________ --------- --------------I------------- ------------- -------------- ----- ----- ------------- ------------- ------- ---- -- Gradezo' 20 s n 2 x 6 16' z0' 20 ui rTs N 20' 20s N 20' 20' N 20' 20' 16' lV 5 20' 20' 0 iV \ 18' 20' 20' $ 18' N 16' 20' 20' ry PURLIN 20' 20 s ConF, struction Grade N 2x4 S zo' 20' N 20' 20' 16' 0� NEW aae�ynmk09� FACIA Bottom Edge of Construction Purlin is 3/4"In �y Grade from Tail of Truss F w 2 x 6 0935d� SS10NP�� P.E. Robbins,P.E. 1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/2017 Page 16 of 24 L L LtBLL LGtiLL 11 Lily NORTH SIDE-EAVE SIDE 2 WALL GIRT VIEW Maestro Eslfmatmg Software POLEBARNS Pott Sams,Goragos&Docks Truss Carrier (3)2 x 10 2 x 4 Bracing Between Posts Attach Brace to #1 SYP One Girts&Posts w/(2)16D Galv.Nails @ Each Notched into the Location Inside PostIM - TYP IM za' 20' ui 0 T-Wall Girt 2 x 4 Construction Grade N 20' 6' S N 10' 821/2 in fV 10' :10' 18' Siding Begin Point 5D Skirt Board 2 x 8 12' 12' 12' 112' 12' 12' 12' m Treated b o 0 of NEi 40' �Q��G Q E'eO r�9 Toe-nail Double 2x4 shelf girt bottom of windows to each Concrete column with (4) .177" x 3.5" nails each end. 4 x is rq � ) 0935% p'�QFES Sill P.E. Robbins, P.E 1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/2017 Page 17 of 24 6 ' L L LIAL LGLLU tl i ' SOUTH SIDE—EAVE SIDE i WALL GIRT VIEW Maestro Extimahkrr. ng Sowa POLE BARNS P.M Berns,G..q-6 0.ckx Truss Carrier (3)2 x 10 2 x 4 Bracing Between Posts Attach Brace to #1 SYP One Girts&Posts w/(2)16D Galv.Nails @ Each Notched Into the Location Inside PostIM -TYP IM IM '. zo' zo' 0 T-Wall Girt 2 x 4 o za i0' Construction Grade 20' zo' 00 N 7 u zoi0' IM 10 10 10, (12' ing Begin Point m Skirt Board M 2 x 8 it it zr it Treated b b OF NEW 40' AQ�� Q E.RO, 0- Toe-nail Toe-nail Double 2x4 shelfIrt bottom of windows to each Concrete g cookie column with (4) .177" x 3.5" nails each end. F� 09350 pR� SS10Np� P E. Robbins,P.E. 1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/2017 Page 18 of 24 41 C�ustt ucti��t1 LilyWEST SIDE-GABLE SIDE 2 WALL GIRT VIEW Maestro® Estimating Software POLE BARNS Pm Bann,Garages&D.C. 2 x 4 Bracing Between Posts Attach Brace to Girts&Posts w/(2)16D Galv Nails @ Each Location TYP �o Ln Ln 0 T-Wall Girt 2X4 In 16' S - 16' Construction Grade N 16' 16' o� N 16' I MT S 16' 1120 in 12' 12' N Siding Begin Point 00 Skirt Board 2x8 16' 20 20, 16 - Treated 0F NEWX09 32' Concrete Cookie 4X15 W 0935 Vq AR�FESSIO��~ P.E. Robbins,P.E. 1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/2017 Page 19 of 24 C�usiLt!cii�n LilyEAST SIDE-GABLE SIDE 1 WALL GIRT VIEW Maestro Es�inalmg soRwam POLE BARNS ""°0a .°amgn8Docks 2 x 4 Bracing Between Posts Attach Brace to Girts&Posts w/(2)16D Galv.Nails @ Each Location TYP 0 T-Wall Girt r. 2 x 4 1 16' Construction Grade N 16' .. ..... 16 I1\\\ zo \ N S 16' JA 1120 in 12' �' .4 N Siding Begin Point m Skirt Board M 2 x B 16' 20' 20' 16' Treated 32' E.Ao O� Concrete Cookie W 4X15 0935b11 A'��FFSSIONP� P.E. Robbins,P.E 1777 State Rt 167 Victoria, IL 61485 PER171458 09/12/2017 Page 20 of 24 �Jy GABLLEDEETAIENw Doors POLI 0AANB No OWRMG FRAME-OUT DETAIL Color-Matched40 Treated Door Post Structural Post 2x4 Girt T �Roofing Screw y ( YP) Y 20 Spacer Blocks REurlin Outside Corner/ Gable Trim 2x4 Girt Truss Top Chord 20 Girt T Gable End Truss Truss Web Structural 4x6 Treated Door Post Siding Zvi i yp. -IsZv R O. x WIND Treated Skirtboard 20 Spacer Blocks FRAME-OUT DETAIL y ■�Structural Post 2x4 Girt(Typ.) J- ��- R.O. - -- - -- 2x4 Window Framing GABLE A' -- - 2x4 Girt T - GABLE DETAIL Structural Post W'OVENMG i 2x4 Girt T Cola-Matched y ' Roofing Screw R.O 2x4 Girt Outside Corner/ 10-1/2" Gable Trim Roof Purim 12" a' 2x4 Girt Fascia Board `!Q� N E{y� Truss Top Chord Sofft 2x4 Framing ' Fj 2x4 Blocking @ 4'o/cOverhang Trim(F&J) Fascia Trim Treated Slortboard Gable End Truss r+ W Truss Web Siding -- -- -- -- `�F� 09350 pRofESS10NP~ P.E. Robbins, P.E. 1777 State Rt 167 Victoria. IL 61485 PER171458 09/12/2017 Page 21 of 24 Alpine, an ITW Company 2820 N.Great Southwest Parkway Grand Prarie,TX 75050 ALPINEwww alpineitw com Site Information: Customer Graber Post Buildings, Inc. Job Number. 1702650 JobDescnption: SCOTT CARTER 32 HORSE Address: City, State,Zip- Southold,NY 11971 Job Engineering Criteria: Design Code. IBC 2009 View Version, 15 02 00 1217 16 JRef#: 1 W3S21930002 Wind Standard: ASCE 7-05 Wind Speed(mph). 130 Roof Load(psf). 25.00-5.00-0.00- Floor Load(psf): None 5.00 This package contains a job notes page, 2 truss drawings and 0 details. Item Seal# Truss Item Seal# Truss 1 241 17 0922 08930 DIY 32 2 241.17.0922.13740 DIY 32G OF NEW hA, A � tk s 08/29/2017 O 4b- 8848$1 FESS t01�Av Printed 8/29/2017 92227 AM P E. Robbins,P E. 1777 State Rt 167 Victoria, IL 61485 PER 171458 09/12/2017 Page 22 of 24 qp Job Number. 1702650 Ply 1 SEQN 220391 /T52 SCIS Cust R2193 JRef 1W3S21930002 SCOTT CARTER 32 HORSE Qty. 9 FROM.WS DrwNo• 241 17 0922 08930 Truss Label: DIY 32 / GO 08/29/2017 6'0'7 11'0'4 16 20'11"12 25'11"9 32' 6'0'7 F 4'11"12 + 4'11'12 4'1112 i 4'1712 80„7 1116X8 4X6 (a) '4X6 12 6 F�7- 90 C 6 :3)�6 m T =10X10 v B ;4X6� 4X6 H 1 A a3 12 =5X12(F1) 5X12(F 1) �10'� r 7'9"13 + 7'5"71 + 7'S"11 7'9"13 r0 8 8 8'6"5 76' 23'5"11 31'3"8 �8.„� '1 8"8 32' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(Ibs) TCLL. 25.00 Wind Std ASCE 7-05 Pg-25 0 Ct 1 1 CAT-II PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL 500 Speed. 130 mph Pf.19.3 Ce.1.0 VERT(LL). 0.450 K 844 240 M 2403 /1409 /1172/- /516 /85 BCLL- 0.00 Enclosure Part Enc Lu- - Cs not used VERT(TL) 0 737 K 516 240 H 2403 /1409 /1172/- /- /85 BCDL 500 Category.II Snow Duration.1.15 HORZ(LL). 0.319 J - - Wind reactions based on MWFRS Des Ld, 3500 EXP.B HORZ(TL) 0 522 J M Min Brg Width Req= 1 9 NCBCLL.0.00 Mean Height 15 00 ft Code/Misc Criteria Creep Factor 1 5 H Min Brg Width Req= 1 9 TCDL.3.0 psf ear Bldg CodeIBC 2009 Max TC CSI0636 Bearings M&H are a rigid surface Soffit. 2.00 BCDL 3 0 sf g . . . P Based on Fcperp=805 psi Load Duration,1 15 MWFRS Parallel Dist 0 to h/2 TPI Std- 2007 Max BC CSI 0 998 Members not listed have forces less than 375# Spacing:48 0" C&C Dist a 3 20 ft Rep Factors Used-No Max Web CSI. 0 906 Maximum Top Chord Forces Per Ply(Ibs) Loc.from endwall.Any FT/RT 20(0)/10(0) Chords Tens.Comp. Chords Tens. Comp. 1 1 0 GCpi 0 55 Plate Type(s)- Wind Duration 1.33 WAVE VIEW Ver 15 02 OOC 1217 16 B-C 7820-6920 E-F 5522 -4973 Lumber C-D 7189-6379 F-G 7188 -6379 D-E 5524-4973 G-H 7818 -6920 Value Set 13B(Effective 6/1/2013) Top chord 2x6 SP 2400f-2 OE Maximum Bot Chord Forces Per Ply(Ibs) Bot chord 2x6 SP 2400f-2.OE Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#2 Lumber value set"13B”uses design values B-L 6177-6600 K-J 5614 -5626 approved 1/30/2013 by ALSC L-K 5614-5522 J-H 6177 -6596 Bracing Maximum Web Forces Per Ply(Ibs) (a)Continuous lateral restraint,equally spaced on Webs Tens.Comp. Webs Tens. Comp. member C-L 991 -402 K-F 1905 -1148 Purlins L-D 373 -506 F-J 435 -506 In lieu of structural panels or rigid ceding use purlins D-K 1905-1148 J-G 991 -428 to laterally brace chords as follows. E-K 3691 -3834 Chord Spacing(in oc) Start(ft) End(ft) TC 24 -088 3288 BC 120 015 1 11 BC 63 1 11 3089 OF NEW BC 120 3089 31 85 Apply purlins to any chords above or below fillersQ �U 0 at 24"OC unless shown otherwise above i Loading * k Truss designed for unbalanced snow loads. S Wind a Wind loads based on MWFRS with additional C&C ' member design O b. 089391 �,' Aft- ESS`1 NIV 08/29/2017 **WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING1 —IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating h ndlin shiDpin installing and bracing Refer to and follow the latest edition of BCSI(Budding Component S fety Information,by TPI ana'S9, f�F safety /actices prior to performing these functions Installers shall provide temporary bracin per 38SI.Unless noted otherwise,top chord shall have proper attached structural sheathing and bottom chord spall have a properly attachad ri id cedm . Locations shown for ermanent lateral restraint f webs shall have bracingg insTailed per BCSI sections B3,B7 or 810, as applicable Appy plates to each face ofptruss and position as shown above and on the Joint Details, unless noted otherwise kefer to ALPINE drawings 16OA-Z for standard plate positions Alpine,a division of ITW Buddingg� omponents Group Inc.shall not be responsible for any deviation from this drawmq,an failure to build the �r truss in conformance with ANSI/T 1 1,or for handling,shipping,installation and bracing of trussesA Seal on this drawing or cover page.. 2g20 N.Great Southwest Parkwa listing this drawing indicates acceptance of ro essrona en ineering respponsibilittyy solei for the desi n shown. The Suitability and listing of this drawing, for any structure is the responsibilitg'of the euildiitg Desigder per'ANSI/TPI 1 S2c.2. Grand Praine,TX 75050 For more mfo?rri3troRI3bbitl 'lQ Eer17rZil rRth3£t7NMeteuia i6 WCIYaAa al RVA466 www t cost org,SSCA www sbcindus corn,ICC www iccsafe or 09/12/2017 Page 23 of 24 ti Job Number: 1702650 Py 1 SEQN 220394 /T53 SCIS Cust R2193 JRef 1 W3S21930002 SCOTT CARTER 32 HORSE Qty: 2 FROM:WS DrwNo. 241.17.0922.13740 Truss Label. DIY 32G / GO 08/29/2017 8711 1111"11 23'8"5 274"5 2'3"4 h`11'S8 2'8"8 r�1'4"�2 � 4'7"11 6'0"7 11'0"4 i 16' i_ 20'0"5 _i 20't1"12 25'11"8 i 32' i 1'4"32 26"8 r 4'0"54-0-5 118 2,3"4 r 47,11 1116XB =3X4 =3X4 =2 5X4 4X6 G 14X 2 5X4 12 =2 t F J=2 5X4 6 =25X4 =25X4 =3X8 E ;3X6 `-o 0 io T =2 X4 D Q V L-2.M4 ao 1 =3X8 =12X16 B =4X10 =010 N 11 i° A a 3 G 12 =5X12(F1) :5X12(F1) P1T8111i 7'7"7 + 7'x7 + r8"1 r0 9 8 8'4"9 16' 23'7"7 31'3"8 8" 8B 32' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(Ibs) TCLL• 2500 Wind Std. ASCE 7-05 Pg-25 0 Ct-1 1 CAT-it PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL. 5.00 Speed. 130 mph Pf.19.3 Ce.10 VERT(LL) 0 431 Q 883 240 X 2403 /1409 /1172/- /516 /8.5 BCLL 000 Enclosure.Part.Enc. Lu- - Cs-not used VERT(TL)• 0 704 Q 540 240 N 2403 /1409 /1172/- /- /8 5 BCDL. 5.00 Category.II Snow Duration.1.15 HORZ(LL) 0 307 P - - Wind reactions based on MWFRS Des Ld 3500 EXP.BHORZ(TL)• 0 502 P - - X Min Brg Width Req= 1 9 Mean Height 15 00 ft NCBCLL 0 00 Code/Misc Criteria Creep Factor.1.5 N Min Brg Width Req= 1.9 TCDL 3 0 psf Bearings X&N are a rigid surface. Soffit. 2.00 BCDL•3 0 psf Bldg Code IBC 2009 Max TC CSI' 0 516 g g Load Duration-1 15 MWFRS Parallel Dist 0 to h/2 TPI Std- 2007 Max BC CSI. 0.975 Based on Fcperp=805 psi Re Factors Used.No Max Web CSI 0 906 Members not listed have forces less than 375# Spacing 48 0" C&C Dist a'3 20 ft P Maximum Top Chord Forces Per Ply(Ibs) Loc from endwall.Any FT/RT•20(0)/10(0) Chords Tens Comp Chords Tens. Comp. I.1.0 GCpi.0 55 Plate Type(s) Wind Duration 1.33 WAVE VIEW Ver 15 02 OOC 1217 16 B-C 7661 -6697 H-I 4687 -4334 Lumber C-D 7908 -7028 I-J 6056 -5367 D-E 7349-6528 J-K 6730 -6037 Value Set 13B(Effective 6/1/2013) Horizontal gable webs are spaced 30 0"o c max E-F 6732-6037 K-L 7347 -6528 Top chord 2x6 SP 2400f-2 OE F-G 6058-5367 L-M 7906 -7028 Bot chord 2x6 SP 2400f-2.OE Lateral restraint(designed by others)perpendicular G-H 4689-4334 M-N 7659 -6697 Webs 2x4 SP#2 to the plane of the member Is required at each end Lumber value set"136"uses design values of the gable horizontal studs and at 24"o c intervals. Maximum Bot Chord Forces Per Ply(Ibs) approved 1/30/2013 by ALSC This restraint is a result of wind applied to the wide Chords Tens Com Chords Tens Com face of the member Refer to BCSI for proper p p Plating Notes required lateral restraint. B-R 5943-6443 Q-P 5734 -5760 Handling stresses not considered for plates Handling ***Transfer of diaphragm loads by R-Q 5734-5755 P-N 5943 -6439 of this truss requires special care by truss budding designer*** manufacturer and installation contractor to prevent End Wall shall be braced to prevent Maximum Web Forces Per Ply(Ibs) plate damage. hinge effect (designed by others) Webs Tens Comp Webs Tens Comp Purlins Refer to appropriate gable web bracing detail for bracing gable horizontal C-R 624 -387 Q-J 588 -501 In lieu of structural panels or rigid ceiling use purlins webs and uplift reactions D-R 904 -660 Q-V 731 -398 to laterally brace chords as follows. E-S 761 -440 U-Q 3188 -3122 Chord Spacing(in oc) Start(ft) End(ft) R-S 389 -393 U-1 1608 -1126 TC 24 -0 88 3288 4 F N FW S-F 406 -446 J-V 406 -446 BC 120 015 1 11 S-Q 731 -398 V-P 389 -394 BC 63 1 11 30.89 1P t p fix/ F-Q 588 -465 V-K 761 440 BC 120 3089 31 85 y g ''g Apply purlins to any chords above or below fillers C� i G-U 1607-1126 P-L 904 -660 at 24"OC unless shown otherwise above * * H-U 3299-3281 P-M 624 -387 Loading s Truss designed for unbalanced snow loads r aC t � r• Wind Wind loads based on MWFRS with additional C&C OSD384 member design 08/29/2017 -WARNING* READ AND FOLLOW ALL NOTES ON THIS DRAWING —IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme Y reme care in fabricatinq,handling,shipping installing and bracing Refer to and follow the latest edition of BCSI(Building Component S fe Information,by TPI anad SBCA fbP safe�(vv Practices prior to perfor7rling these functions. Installers shall provide temporary bracing per 38SI Unless noted olherwise,top chord shall nave prro. I attached structural sheathing and bottom 4hor�stlall hav a pro[�erly attach8d risld cellin Locations shown for rmanent lateral restraint of webs shall have bracing installed per BCSI sections B3,�7 or 610, as applicable Applgy Oates to each face of truss and position as shown above and on the JoinTDetails, unless noted otherwise. Refer to A LPI N E drawings 160A-Z for standard plate positions. Alpine,a division of ITW Buildingg�Components Group Inc shall not be responsible for any deviation from this drawinp an failure to build the II truss in conformance with ANSI 1,or for handling,shipping,installation and bracing of trussesA seal on this drilwi or cover pa e,, 48Po N Great Southwest Parkwa listing this drawingg indicates acceptance of prd)essionaT en ineering responsibilit�sole) for th desi n sho n. The su' bility and Else of this a�awin for any structure is the responsibilit�of the BuildIng Desigder pePANSIITPI 1 5�c.2. Grand Prairie,TX 75050 For more infer r�tio�tNE1 'P Eer117rZi& rRth3£a7,Mictafia OlAg&ip@iRtM466wwwtpinstorg,SBCA wwwsbcindustryconi,1CC www iccsafe or 09/12/2017 Page 24 of 24