HomeMy WebLinkAbout42804-Z ��SUFFat,��a Town of Southold 9/25/2018
a P.O.Sox 1179
0
c 53095 Main Rd
®yaps Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 39917 Date: 9/24/2018
THIS CERTIFIES that the building ADDITION/ALTERATION
Location of Property: 1645 Westphalia Rd.,Mattituck
SCTM#: 473889 Sec/Block/Lot: 141.4-6
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
6/12/2018 pursuant to which Building Permit No. 42804 dated 6/19/2018
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
"AS BULT"ADDITION AND ALTERATIONS INCLUDING ROOF OVER EXISTING DECK AND A
NON-SLEEPING STORAGE LOFT IN AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR
The certificate is issued to Friedman,Brian&Horton-Friedman,Crystal
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 42804 08-29-2018
PLUMBERS CERTIFICATION DATED 08-21-2018 Harky Plumbing
ho ' e Signature
SvfFoc,r� TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
oma. SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 42804 Date: 6/19/2018
Permission is hereby granted to:
Friedman, Brian
PO BOX 1678
Mattituck, NY 11952
To: legalize "as built" deck addition and construct additions and alterations to single-family
dwelling as applied for. Additional certification may be required.
At premises located at:
1645 Westphalia Rd., Mattituck
SCTM # 473889
Sec/Block/Lot# 141.-1-6
Pursuant to application dated 6/12/2018 and approved by the Building Inspector.
To expire on 12/19/2019.
Fees:
AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $716.00
CO -ADDITION TO DWELLING $50.00
Total:, $766.00
B spector
Form No.6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 10/,lead.
5. Commercial building,industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings(prior to April 9,1957)non-conforming uses,or buildings and;,"pre-existing"land uses:
1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is
denied,the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00,Alterations to dwelling$25.00,
Swimming pool$25.00,Accessory building$25.00, Additions to accessory building$25.00,Businesses$50.00.
2. Certificate of Occupancy on Pre-existing Building- $100:00
3. Copy of Certificate of Occupancy-$.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00
Date. June 6th 2018
New Construction: Old or Pre-existing Building: (check one
Location of Property: 1645 Westphalia Rd Mattituck
. House No. Street Hamlet
Owner or Owners of Property: Crystl Horton and Brian Freedman
Suffolk County'Tax Map No 1000, Section 141 Block 01 Lot 6
SubdivisionQQ Filed Map. Lot:
Permit No. v
OV Date of Permit. Applicant:
Health Dept. Approval: Underwriters Approval:
Planning Board Approval:
Request for: Temporary Certificate Final Certificate: �/ (check one)
Fee Submitted: S
ant Signature
pF SOUjyol®
Town Hall Annex Telephone(631)765-1802
54375 Main Road Fax(631)765-9502
P.O.Box 1179 G Q
�► • �o roger.riche rt(Q-town.south old.ny.us
Southold,NY 11971-0959 O
�yNT`1,�
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICIAL COMPLIANCE
SITE LOCATION
Issued To: Friedman/Horton
Address: 1645 Westphalia Rd City: Mattituck St: New York Zip: 11952
Budding Permit#. 42804 Section: 141 Block- 1 Lot, 6
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: AS BUILT DBA: License No:
SITE DETAILS
Office Use Only
Residential X Indoor X Basement X Service Only
Commerical Outdoor X 1st Floor X Pool
New Renovation 2nd Floor X Hot Tub
Addition Survey X Attic Garage
INVENTORY
Service 1 ph 200a Heat gas Duplec Recpt Ceiling Fixtures HID Fixtures
Service 3 ph Hot Water elec GFCI Recpt Wall Fixtures Smoke Detectors
Main Panel 200a A/C Condenser Single Recpt Recessed Fixtures CO Detectors
Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps
Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks
Disconnect 200, Switches Twist Lock Exit Fixtures 11 TVSS El
Other Equipment, "AS BUILT" "ELECTRICAL SURVEY" "NO VISUAL DEFECTS"
------WHOLE HOUSE--------
Notes. To include,gas furnace,electric hot water heater,new romex wiring originating at service panel in basement.
Inspector Signature: Date: August 29 2018
81-Cert Electrical Compliance Form As
�����p� �k
o �
Town Hall Annex Telephone(631)765-1802
54375 Main Road Fax(631)765-9502
P.O.Box 1179
Southold,NY 11971-0959
;fl
D
BUILDING DEPARTMENT
TOWN OF SOUTHOLD JVr.
AUG 2 7 2018
T,*
CERTIFICATION
Date:
Building Permit No.
Owner: Q td(Yt an
(Please print)
Plumber:
(Please p
I certify that the solder used in the water supply system contains less than 2/10 of 1%
lead.
(Plumbers S' nature)
Sworn to before me this 2- 1
day of_ Auaus-)- 20
I A
V-
Z� -4'*N0-01VE6132423,,*.*AS
LiflEDIN-.,"
LX
Notary Public, County C0UNjY
0
4
0f
ID Ifho�aOF 50UTyo�
TOWN OF SOUTHOLD BUILDING DEPT.
`ycourm, 765-1602
INSPECTION
[ ] FOUNDATION 1ST [/RGH PLBG.
FOUNDATION 2ND [ ATION
[ ] FRAMING /STRAPPING [ ] FINAL
[ ] -FIREPLACE & CHIMNEY [ W] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT.CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] CAULKING
REMARKS:
' Q,� 6 JQf(A I �� ✓ 0k) AV
Wso ft(� -
�wl r
?)?XA4l'c6CchklkcOv* at AA?JJ
-� irtouP"mxt/
o� W obi r.�JinAn�� h
.01
A o� a
DATE INSPECTOR
OE SO�T�°
# * TOWN OF SOUTHOLD BUILDING DEPT.
courm, 765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PL13G.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING /STRAPPING [%,j/FINAL• 0!A'
[- ] FIREPLACE & CHIMNEY [ ] -FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] CAULKING
REMARKS: j
%'Cl D PFJ 00 6 W� •
�.� A;v leo' A� �✓�v�a�
0
,. C -jv w- m —art
An1 � 1l A3 Vl
C., G2� vel _
DATE INSPECTOR
OF SO(/lyO�
# TOWN OF SOUTHOLD BUILDING DEPT.
courm, 765-1802
INSPECTION _
[ ] FOUNDATION 1ST [ ] ROUGH PLBG. U
[ ] FOUNDATION 2ND- [ ] INSULATION
[ ] FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE &-CHIMNEY - [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] CAULKING
REMARKS:
g,-.d -®
DATE ? INSPECTOR
OF SOUIyOIo
# TOWN-OF SOUTHOLD BUILDING DEPT.
couto" , 765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING /STRAPPING [toYo`F' INAL �Po
[ -] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] CAULKING
REMARKS:
DATE �' INSPECTOR
• • • • ��� jjCOMMEENTS
FOUNDATION (IST) ��; I .�
�.
ROUGHYOUNDATION
ILL W,17,PXI U
ENERGYPLUMBING
INSULATION PER N.Y.
•D
MINAMWE
IMF - ■
MW,t om
ADDITIONAL COMMENTS
MINVE all r
•
•
OWN OF SOUTHOLD' BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following,before applying?
TOWN HALL Board of Health
SOUTHOLD,NY 11971 4 sets of Building Plans
TEL: (631) 765-1802 Planning Board approval
FAX: (631)765-9502q
Survey -
SoutholdTown.NorthFork.net PERMIT NO. 446 Check
Septic Form
N.Y.S.D.E.C.
Trustees
C.O.Application
Flood Permit
Examined 201D Single& Separate
Storm-Water Assessment Form
0
JUN 1 2 2018 contact:
Approved 20_ Mail to: Robert Wilson
Disapproved a/c ]BU` _,>� DE � PO Box 49 Southold NY 11971
16 TOWN OF SOIL L Phone: (631)504-8842
Expiration 20
Buildin or
APPLICATION FOR BUILDING PERMIT
Date June 5th , 20 18
INSTRUCTIONS
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, accurate plot plan to scale.Fee according to schedule.
b.Plot plan showing location of lot and of buildings on premises,relationship to-adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the-interim,the Building Inspector may authorize,in writing,the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or
Regulations,for the construction of buildings, additions, or alterations or for removal or demolition-;as herein described. The
applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections.
(Signature of applicant or name,if a corporation)
PO Box 49 Southold NY 11971
(Mailing address of applicant)
State whether applicant is owner, lessee,agent, architect, engineer, general contractor,electrician, plumber or builder
Agent
Name of owner of premises Crystl Horton and Brian Freedman
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No.
1. Location of land on which proposed work will be done:
1645 Westphalia Rd. Mattituck
House Number Street Hamlet
County Tax Map No. 1000 Section 141 Block 01 Lot 6
Subdivision Filed Map No. Lot
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy Single family residential
Same with existing wood access ramp removed and new 395 sq ft deck built attached to rear of residence Roof was
occupancy added and the center section of the roof was intended to be a a roof deck accessible from a door on the 2nd floor.This work
b. Intended use and
was never completed.Proposed work is to replace existing door with a window of same size and add new rafters in cents
section thereby eliminating the half-built roof deck
3. Nature of work(check which applicable): New Building Addition V Alteration V
Repair Removal Demolition Other Work
(Description)
4. Estimated Cost Fee
(To be paid on filing this application)
5. If dwelling, number of dwelling units 1 Number of dwelling units on each floor 1
If garage, number of cars
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. Dimensions of existing structures, if any: Front 25'-9" Rear 26'-3" Depth 40'-6"
Height 22' Number of Stories 2
Dimensions of same structure with alterations or additions: Front 25'-9" Rear 25'-6"
Depth 56-0-3/4" Height 22' Number of Stories 2
8. Dimensions of entire new construction: Front 25'-6" Rear 25'-6" Depth 16-6-3/4"
Height 16' Number of Stories 2
9. Size of lot: Front 93.42' Rear 83.15' Depth 263.00'
10. Date of Purchase Name of Former Owner
11. Zone or use district in which premises are situated R-40 Medium Density residential
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO V
13. Will lot be re-graded? YES NO V Will excess fill be removed from premises? YES NO \/
Crystl Horton and 1645 Wesphalia Rd
14. Names of Owner of premises Brian Freedman Address Mattituck NY 11952 Phone No. (631)504-8842
Name of Architect Address Phone No
Name of Contractor Address Phone No.
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO
* IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO V
* IF YES,D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey,to scale,with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES NOS/
* IF YES,PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUNTY OFSf bA t4)
Robert Wilson being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)He is the Agent
(Contractor,Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
Sworn tq before me this
V9 day of 0Uyl Q 20 _
JA(1,r I'_4 ZI E&D'A f�
otary Public Sig icant
Scott A. Russell ,��°su���� ST01KMWA\'7F]E1K
sUPERvis®R W - I��1[ANAGE]EMIE NT
SOUTHOLD TOWN HALL-P.O.Box 1179 b
53095 Main Road-SOUTHOLD,NEWYORK 11971 4#_ _ Town of Southold
CHAPTER 236 - STORMWATER MANAGEMENT WORK SKEET
( TO BE COMPLETED BY THE APPLICANT )
DOES THIS PROJECT INVOLVE ANY OF THE FOLLOWING:
Yes No (CHECK ALL THAT APPLY)
❑❑ A. Clearing, grubbing, grading or stripping of land which affects more
than 5,000 square feet of ground_surface.
0 B. Excavation or filling involving more than 200 cubic yards of material
within any parcel or any contiguous area.
❑® C. Site preparation on slopes which exceed 10 feet vertical rise to
100 feet of horizontal distance.
❑❑ D. Site preparation within 100 feet of wetlands, beach, bluff or coastal
erosion hazard area.
❑❑ E. Site preparation within the one-hundred-year f loodplain as depicted
on FIRM Map of any watercourse.
❑® F. Installation of new or resurfaced impervious surfaces of 1,000 square
feet or more, unless prior approval of a Stormwater Management
Control Plan was received by the Town and the proposal includes
in-kind replacement of impervious surfaces.
If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name,
Signature, Contact Information, Date & County Tax Map Number! Chapter 230,does not apply to your project.
If you answered YES to one or more of the above,please submit Two copies of a Stormwater Management Control Plan
and a completed Check List Form to the Building Department with your Building Permit Application.
APPLICANT. (Property Owner,Design Professional,Agent.Contractor,Other) S.C.T.M. 1000 Date-
District
NAME. Robert Ilson 141 01 06 June 5th 2018
Section Block Lot
FOR BUILDING DEPARTMENT USE ONLY****
Contact Information. (631)504-8842
ffrkphanr Numbc[1
Reviewed By:
Date:
Property Address/Location of Construction Work: teApproved
— — — — — — — — — — —
1645 Westphalia Rd. for processing Building Permit.
tormwater Management Control Plan Not Required.
Maft ituck NY 11952 Stormwater Management Control Plan is Required.
® (Forward to Engineering Department for Review.)
FORM # SMCP-TOS MAY 2014 ~�
guEFQI,� 1 BUILDING DEPARTMENT- Electrical Inspector
�p �D TOWN OF SOUTHOLD
2�1� Town Hal 5New1R1971-0959 5MainYork d Box 1179
zoo
Southold
way • pvG .T lephone (631) 765-1802 - FAX (631) 765-9502
P roger riche rtc�town.southold.ny_us
APO'LICATION FOR ELECTRICAL INSPECTION
REQUESTED-BY." -
- ------------ --------- --- ----- - - Date: Zg- - - - - -- - --
Company Name:
Name:
License No.: � email:
Address: i5 ,- I
Phone No.:
JOB SITE INFORMATION: (All Information Required)
Name: 1�
Address:
Cross Street:
Phone No.: ti
Bldg.Permit#: a,�Q email: L a a Cy-\
Tax Map District: 1000 Section: 14 Block: Lot:
BRIEF DESCRIPTION OF WORK (Please Print Clearly)
o . �-
Circle All That Apply:
Is job ready for inspection?: YES / NO Rough In Final '
Do you need a Temp Certificate?: YES /Q NO Issued On
Temp Information: (All information required).
Service Size 1 Ph 3 Ph Size: A # Meters Old Meter#
New Service- Fire Reconnect- Flood Reconnect- Service Reconnected - Underground - Overhead
# Underground Laterals 1 2 H Frame Pole Work done on Service? Y N
Additional'Information:
PAYMENT DUE WITH APPLICATION
0
�(b
Request for Inspection FormAs tv
V�
f
Town Hall Annex �� �:� Telephone(631-1802
54375 Main Road -c • Fax(631)734-9502
P_ Q, Box 1179 C Iz
Southold, NY 11971-0959
�. - .=i4. .,. .. 'G ,1Cr_.�;�Y.��►' i��:�b�'�:r.:a s . x'S,i� ... ,. � ,i'. r,t, ,L•.:� ...
BUILDING DEPAR'TMENTf `}
1
in NOTICE OF UTILVATION OF*TRUSS TYPE,G NSTRUCTION. PRE-
ENGINEERED
r, WOOD CONSTRUCTION ANDId TIMBER,'CO`ffSTRUCTION
Dake: June 5th
Grystl"Horton=and Bah ' ' l''
Oiiirner: �Fre$'dman, ,�.•; rr�„ •�M,,`
' Lotc�ation of Property: 1.645 Wastpa
Rd. Ilattituck=.NYh1 952 ' ' t
e i '---;
P1e se take notice that4thel(check-applicable
New residential°s ructord, , .
$ =x V Addlfion to existing resid 60al Wt ttocidre j c'' x
•:n }Ary '+t"A•�Zi'hS • .4
Rehabilitation
�
Rehabilitation to an epsti� g.iresident&t.,str-uci .*�-
to be const acted or performed at the s.kbjpct<property rWergnce abovg will utilize,
(check applicable tine): tt�
' 4 Truss type.construction ( Tj•->•;%�s
Pre-engineered wood constructionsP...1!}ov:;-�.
V Timber constructiorr (T ).
in tl* following iocation(s)(check applicable mieg'
Floor framing. i .'r,,a4 i • �,: =1_. ` .
• a _including girdlers-anda' eamts'(F) --
>1 Roof fxaming (fi) -
�Y v Floor and roof framing (FR)
4
-Y
:4
� i.)���~'+!,'�y"'A•(' 3a i ^'y't`.i 4 S 5`• � C Q t / i •�t is .z,�•r'" ,
1_ - r .°..a-+r.evr_ss•t.,,^s.cs.c.&t«:.::Jz' .e.a.n a. ._. _ •..w.n _..e .+. -
Signature:
Name:(person su6rnittirag f[is form): RotierflNlson
t �':i.1 .',,•'• r '%fit' k , v ,.�. �.r,�t t 4 � r� ! f: ., t 7 -
CapacitX(checkfapplica�le laid):
_
. .»� � �.{L,,,,�,,,, tr e y',.; ._�« �3(ti ., epi x •-y-� ''�Y `t Z.� t ��� ..1'S^ •+, ^fi'.' 1 > x r .I 4�
_ �OYv1:1er_A LLa x , ..� e'�. � _ �.. _ t ,r ,_� .�� a �`'• l� .�3 .. _ s fit, , .�,^§�+,•
=VVV/ .O w,me'r-re'pmsentative
t
TrussResReQ15-doCK _'Effectivb%1fJ/2075
Jarski, John
From: Jarski,John -
Sent: Tuesday,August 28, 201 6)
8:28 M
To: 'Crystl Horton'
Subject: RE:Window and Door specs and Boiler specs and insulation specs
Good morning,
I have received the specifications for the mechanicals and windows.Thank you. Here is what I need in order to issue
the certificate of occupancy: 1. Electric application,electric inspection and electric certificate.(this is all done from within
the Building Dept.), 2. Build/construct or take measures to create proper loft storage.(1 will need to inspect what
happens here), 3. Revise/amend plan for all corrections.
From: Crystl Horton<chorton@dfrg.com>
Sent: Friday,August 24, 2018 3:18 PM
To:Jarski,John<johnj@southoldtownny.gov>
Subject:Window and Door specs and Boiler specs and insulation specs
Hi John- This is Crystl Horton-the owner of the Westphalia home. I have attached specs for the windows and
doors and boiler etc for the home. Please let me know that this is what you need and anything else I can do to
facilitate this as my buyer is literally going to walk away from this deal and I really cannot afford to let that
happen. Thank you for your help.
Crystl Faye Horton
Wine Director
Del Frisco's Double Eagle Steakhouse, New York City, NY
1221 Avenue of the Americas, NY, NY 10020
Chorton@dfrg.com
P: 212.575.5129
CONFIDENTIALITY NOTICE:This electronic transmission and any documents or other writings sent with it constitute confidential information,which is
intended only for the named recipient.If you are not the intended recipient,please reply to the sender that you have received the message in error
and delete it.Any disclosure,copying,distribution or the taking of any action concerning the contents of this communication or any attachment(s)by
anyone other than the intended recipient is strictly prohibited.
Message history
CONFIDENTIALITY NOTICE: This electronic transmission and any documents or other writings sent with it
constitute confidential information,which is intended only for the named recipient. If you are not the intended
recipient,please reply to the sender that you have received the message in error and delete it. Any disclosure,
copying, distribution or the taking of any action concerning the contents of this communication or any
attachment(s) by anyone other than the intended recipient is strictly prohibited.
i
Jarski, John
From: Crystl Horton <chorton@dfrg.com>
Sent: Tuesday,August 28, 2018 11:33 AM
To: Jarski,John
Subject: Re:Window and Door specs and Boiler specs and insulation specs
Hello John,
I spoke to Robert on Friday and he said that the amended plans are at the engineer. He also said that he
spoke to you personally and that you were fine with the loft as long as the ladder was removed-which we
have done. He also said that he submitted the application for the electrical inspection but when I called today
they said they do not have it. Can you email it to me and I will submit it as it appears that my expediter does
not understand or comprehend the scope of his job. Please let me know if this all sounds good. If I do not get
the CO on the house this week my buyer is going to walk away and I frankly cannot afford that to happen. If
there is anything else I can do to ensure that the CO goes through please let me know. Thank you
again. Crystl
Crystl Faye Horton
Wine Director
Del Frisco's Double Eagle Steakhouse, New York City, NY
1221 Avenue of the Americas, NY, NY 10020
Chorton@dfrg.com
P: 212.575.5129
CONFIDENTIALITY NOTICE:This electronic transmission and any documents or other,writings sent with it constitute confidential information,which is
intended only for the named recipient.If you are not the intended recipient,please reply to the sender that you have received the message in error
and delete it.Any disclosure,copying,distribution or the taking of any action concerning the contents of this communication or any attachment(s)by
anyone other than the intended recipient is strictly prohibited
From:Jarski,John<johnj@southoldtownny.gov>
Sent:Tuesday,August 28,2018 8:28:01 AM
To:Crystl Horton
Subject: RE:Window and Door specs and Boiler specs and insulation specs
Good morning,
I have received the specifications for the mechanicals and windows.Thank you. Here is what I need in order to issue
the certificate of occupancy: 1. Electric application,electric inspection and electric certificate.(this is all done from within
the Building Dept.), 2. Build/construct or take measures to create proper loft storage.(I will need to inspect what
happens here),3. Revise/amend plan for all corrections.
From: Crystl Horton<chorton@dfrg.com>
Sent: Friday,August 24, 2018 3:18 PM
To:Jarski,John<johnj@southoldtownny.gov>
Subject:Window and Door specs and Boiler specs and insulation specs
Hi John- This is Crystl Horton-the owner of the Westphalia home. I have attached specs for the windows and
doors and boiler etc for the'home. Please let me know that this is what you need and anything else I can do to
1
facilitate this as my buyer is literally going to walk away from this deal and I really cannot afford to let that
happen. Thank you for your help.
Crystl Faye Horton
Wine Director
Del Frisco's Double Eagle Steakhouse, New York City, NY
1221 Avenue of the Americas, NY, NY 10020
Chorton@dfrg.com
P: 212.575.5129
CONFIDENTIALITY NOTICE:This electronic transmission and any documents or other writings sent with it constitute confidential information,which is
intended only for the named recipient.If you are not the intended recipient,please reply to the sender that you have received the message in error
and delete it.Any disclosure,copying,distribution or the taking of any action concerning the contents of this communication or any attachment(s)by
anyone other than the intended recipient is strictly prohibited.
Message history
CONFIDENTIALITY NOTICE: This electronic transmission and any documents or other writings sent with it
constitute confidential information,which is intended only for the named recipient. If you are not the intended
recipient,please reply to the sender that you have received the message in error and delete it. Any disclosure,
copying, distribution or the taking of any action concerning the contents of this communication or any
attachment(s)by anyone other than the intended recipient is strictly prohibited.
CONFIDENTIALITY NOTICE: This electronic transmission and any documents or other writings sent with it
constitute confidential information, which is intended only for the named recipient. If you are not the intended
recipient,please reply to the sender that you have received the message in error and delete it. Any disclosure,
copying, distribution or the taking of any action concerning the contents of this communication or any
attachment(s)by anyone other than the intended recipient is strictly prohibited.
2
Jarski, John
From: Crystl Horton <chorton@dfrg.com>
Sent: Tuesday,August 28, 2018 3:28 PM
To: Jarski,John
Subject: Re:Window and Door specs and Boiler specs and insulation specs
Hi John-Robert told me that he spoke to you personally and you told him that the storage area was fine as long
as the access to the area was removed. The ladder has been removed now. I am not out there- I live in
manhattan and do not go out there either. I have now had to pay a great deal of money to everyone to make the
changes that you have required but what I am not understanding is why the requirements change each time
either I speak to you or my expediter speaks to you.
Originally I was told the storage area simply had to be clearly labeled on the drawings as storage. It is not of
legal height clearance for it to be anything else.
I had the architect redraw the plans which were labeled with the area as storage. You said the arrow was
pointing in the wrong direction on the plans.
Next I was told that a wall had to be erected and a gate with a latch put up. I asked my expediter to clarify with
you the issue and he came back and said you were fine with the storage area as long as the ladder was taken
down so there was no access to it. So I hired someone to go out there and take the ladder down.
Now my realtor is telling me that you were speaking to the buyers lawyer about my house and told her that you
were still want a wall and a gate.
I cannot keep playing this game here-I have a buyer who is going to walk away and I need this to be done.
Cheers!
Crystl Horton
Wine Director Del Frisco's New York
Sent from my iPhone
On Aug 28, 2018, at 8:28 AM, Jarski, John<johninn,southoldtownny.gov>wrote:
Good morning,
I have received the specifications for the mechanicals and windows.Thank you. Here is what I need in
order to issue the certificate of occupancy: 1. Electric application, electric inspection and electric
certificate.(this is all done from within the Building Dept.), 2. Build/construct or take measures to create
proper loft storage.(I will need to inspect what happens here),3. Revise/amend plan for all corrections.
From:Crystl Horton<chorton@dfrg.com>
Sent: Friday,August 24, 2018 3:18 PM
To:Jarski,John<iohni@southoldtownny.gov>
Subject:Window and Door specs and Boiler specs and insulation specs
Hi John- This is Crystl Horton-the owner of the Westphalia home. I have attached specs for
the windows and doors and boiler etc for the home. Please let me know that this is what you
need and anything else I can do to facilitate this as my buyer is literally going to walk away from
this deal and I really cannot afford to let that happen. Thank you for your help.
Crystl Faye Horton
i
Wine Director
Del Frisco's Double Eagle Steakhouse, New York City, NY
1221 Avenue of the Americas, NY, NY 10020
Chorton@dfrg.com
P: 212.575.5129
CONFIDENTIALITY NOTICE:This electronic transmission and any documents or other writings sent with it constitute confidential
information,which is intended only for the named recipient If you are not the intended recipient,please reply to the sender that
you have received the message in error and delete it.Any disclosure,copying,distribution or the taking of any action concerning
the contents of this communication or any attachment(s)by anyone other than the intended recipient is strictly prohibited.
Message history
CONFIDENTIALITY NOTICE: This electronic transmission and any documents or other
writings sent with it constitute confidential information, which is intended only for the named
recipient. If you are not the intended recipient, please reply to the sender that you have received
the message in error and delete it. Any disclosure, copying, distribution or the taking of any
action concerning the contents of this communication or any attachment(s) by anyone other than
the intended recipient is strictly prohibited.
CONFIDENTIALITY NOTICE: This electronic transmission and any documents or other writings sent with it
constitute confidential information, which is intended only for the named recipient. If you are not the intended
recipient,please reply to the sender that you have received the message in error and delete it. Any disclosure,
copying, distribution or the taking of any action concerning the contents of this communication or any
attachment(s)by anyone other than the intended recipient is strictly prohibited.
2
pF SOUr�®l
Town Hall Annex Telephone(631)765-1802
54375 Main Road Fax(631)765-9502
P.O.Box 1179 G Q
Southold,NY 11971-0959 'Q
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
September 10, 2018
Brian Friedman
P.O. Box 1678
Mattituck, New York 11952
IOTE:R6. 45 Westphalia Road, Mattituck
!Amended plans required before the Certificate of Occupancy can be processed.
TO WHOM IT MAY CONCERN:
The items marked below are required to obtain your Certificate of Occupancy
Application for Certificate of Occupancy. (Enclosed)
Electrical Underwriters Certificate. (Electrical Inspector 631-765-1802)
A fee of$50.00.
Final Survey with Health Department Approval.
Plumbers Solder Certificate or Pex Affidavit
Trustees Certificate of Compliance. (Town Trustees # 765-1892)
Final Planning Board Approval. (Planning # 765-1938)
Final Fire Inspection from Fire Marshall. (631-765-1802)
Final Landmark Preservation approval.
Final Elevation Certificate required.
Final Storm Water Runoff Approval from Town Engineer
Spray Foam Insulation certification from a NYS licensed architect or
engineer
BUILDING PERMIT: 42804-Z "as built" additions/alterations
I � `
I � I
o �
s
N N
n �R
I
J
Z �
IN
v
Is
U
$0
3j
OF NES
co
LOW 0
t�--�►.C.�T�'1" 1 TyGi•�. G....�ocZ .To��
L.C.
�
P.O.Bo+C Q'�3���..-s[�ti1►._IJF+.''S'YJ r—J`I ,
may.. aT acv i v v.r�u i i 1 u 1 un Nu i
t
♦ ,1
Specifications for 1645 Westphalia Rd. Matti
Crystl F. Dorton CP)
AUG 242018
917580-5628 r�
I��L 1' MTM DR
KU UD Water Heater Model #XG50512DM40UU '
Basement: 5X American Craftsman #70 Slider Buck
Windows
F, n ,r Way: 1 Foather ]fiiveis Madel 4F F3790 Duur
Stairwell: 1 Anderson Model 09117172 Window
Foyer+ 2XI(Anderson Model #DH4039
Downstairs Bathroom: 1 Jeld-Wen Model
#THDJW142100102 Window
1 Anderson Model #CW14R Window
Kitchen: 1 Jeld-Wen Model #THDJW142100102 Window
4X Anderson Model #CN235LR Window
1 MP Doors Model #HT6068L00201 Door
Dining Room :.1 Jeld-Wen Model #THDJW142100102
Window
2X Anderson Model #DH2O30 Window
Livin Room: 3X Anderson Model 4039 Window
3X Andersun Model DR 2030 Window
Aug 24 2018 0322PM HP Fax page 2
Second Floor
Front Bedroom: 1 Anderson Model DH 2030 Window
2 Anderson Model ISH 4039 Window
1 Anderson Model A31V Window
Walk-in Closet: 2X Anderson Model CW14R Window
Middle Bedroom. 2X Anderson Model #DH4039 Window
Master Bedroom: 2X Anderson Model #DH4039 Window
2X Anderson Model #CW14R Window
Master Bath: 1 Jeld-Wen Model #THDW138500117
Window
1 American Craftsman Model #2838786 Window
Aug 24 2018 0322PM HP Fax page 3
t
RUUD Water Heater
Model # XG50512DM40UO
Pacemaker (Standard and Ultra Low NOx)
Check Rebate Avaflability
• Features
• Specs/Docs
• Warranties
• Financing,
Pacemaker@ gas water heaters feature the Guardian System–engineered to exceed ANSI standards for flammable vapor ignition
resistance
Features;
Efficiency
• .58-.62 EF
• More hot water at a low operating cost
Performance
• FHR:50 to 90-gallons for natural gas
• Recovery:30.3 to 50.5 gallons at a 90 degree rise,based on model Guardian System—&Sensor
• Exclusive air/fuel shut-off device
• Maintenance free–no filter to clean
Aug 24 2018 03:22PM HP Fax page 4
Lose Emissions
• Meets 40 ng/J NOx requirements
Longer Life
• Patented magnesium anode rod with resistor protects the tank from rust
High Altitude Compliant
• All models certified up to 6,000 ft.above sea level
• Some models certified up to 10,200 R above sea level,check factory for listings
Plus...
a Easy to light—no matches required
• EverKleenTm patented system figbts sediment build-up
• Brass drain valve and temperature and pressure relief valve are included
• Standard replacement parts
DESCRIPTION ENERGY INFO
PACEMAKER MODELS
ENERGY
TYPE GAL CAP. MODEL NUMBER FACTOR ENERGY STARQD
NAT.
STANDARD PACEMAKER MODELS
TALI. 29 P2-30F 0.62
40 P40-36171 0.59
40 P2AOFl 0.59
38 P112-40F 0.60
40 PH2R40.40F 0.62
50 P1121150-40F 0.62
50 P2-50F1 0.58
50 P112-50-4017 0.58
SHORT 30 P2-30S-30F 0.61
40 P2R-44SF 0.62
40 P2-40SF 0S9
40 PH2-40SF 0.59
50 PH50SF 0.59
PACEMAKER ULTRA LOW NOx MODELS
TALL 28 P2-30FN 0.62
68 P2-40FN 0.60
40 P2R-40FN 0.62
48 P2-50FN 0.58
50 P2R-50FN 0.62
60 PH2.60FN 0.56
SHORT 38 P2408FN 0.60
*
"One installed in basement
Aug 24 2018 0322PM HP Fax page 5
Specifications Owens Corning R-19 Eco Touch Insulation
Model # RF40 For Walls
Dimensions
Coverage Area(sq.ft.)
48.96
Product Depth(in.)
470.4
Product Height(in.)
6.25
Product Length(ft.)
39.2 ft
Product Thickness (in.)
6.25 in
Product Width(in.)
15
Details
Faced or Unfaced
Faced
Formaldehyde Free
Yes
Insulation Application Type
2x6 Walls,Attics,Ceilings,Floors
Insulation R-Value
19
Insulation Type
Fiberglass
Product Weight(lb.)
17.11b
Roll or Batt
Roll
Vapor Retardant
Yes
Warranty/Certifications
Warranty Information
Limited Lifetime
"Installed in walls
Aug 24 2018 03:22PM HP Fax page 6
Specifications Owens Corning Eco Touch R-30 Unfaced
Fiberglass Insulation Model # RU70 for Attics
Dimensions
Coverage Area(sq. ft.)
31.25
Product Depth(in.)
300
Product Height(in.)
9
Product Length(ft.)
25 ft
Product Thickness(in.)
9 in
Product Width(in.)
15
Details
Faced or Unfa_ ced
Unfaced
Formaldehyde Free
Yes
Insulation Application Type
Attics,Ceilings,Floors
Insulation R-Value
30
Insulation Type
Fiberglass
Product Weight(lb.)
16.91b
Roll or Batt
Roll
Vapor Retardant
No
Warranty I Certifications
Warranty Information
Limited Lifetime
**Installed in attic
Aug 24 2018 0322PM HP Fax page 7
Specifications Feather River Model FF3790 Craftsman
Front Door
Dimensions
Door Height(in.)
81.625
Door Thickness(in.)
1.75 in
Door Width(in.)
37.5
Jamb Size(in.)
4-9/16"
Rough Opening Height(In.)
82.125 in
Rough Opening Width(In.)
38.25 in
Details
Bore Type
Double Bore
Color Family
Chestnut
Color/Finish
Mahogany Woodgrain: Pre-Finished Chestnut
Door Configuration
Single Door
Door Glass Insulation
Dual Pane,Flush Glazed,Tempered
Door Handing
Left-Hand/Inswing
Door Style
Beach Style,Carriage,Classic,Craftsman,Farmhouse
Door Type
Exterior Prehung
Features
Brickmold,Lockset Bore (Double Bore),Weatherstripping
Finish Type
Stained
Frame Material
Wood
Glass Caming Finish
No carving
Glass Style
Aug 24 2018 03:23PM HP Fax page 8
Clear
Glass Type
6 Lite
Hinge Finish
Patina
Hinge Type
Ball Bearing
Included
No Additional Items Included
Material
Fiberglass
Number of Hinges
3.0
Panel Type
2 Panel
Product Weight(lb.)
921b
Suggested Application
Back,Front,Side
Warranty/Certifications
Energy Star Qualified
North-Central,Northern,South-Central,Southem
Manufacturer Warranty
Limited Lifetime Warranty; 2 Year Finish Warranty
How can we im rove our product information?Provide f edback.
"*Ono Inat2II9d In front entryway.
r
Aug 24 2018 03:23PM HP Fax page 9
Specifications MP Doors Fiberglass Patio Door Model #
HT6068L00201
Dimensions
Door Height(in.)
80
Door Thickness (in.)
1.75 in
Door Width(in.)
72
Rough Opening Height(In.)
79.75 in
Rough Opening Width(In.)
71-112 in
Details
Bore Type
Double Bore
Color Family
White
Color/Finish
Smooth White Exterior and Interior
Core Type
Solid Core
Door Configuration
Double Door
Door Glass Insulation
Double-Glazed,Flush Glazed,Low-E,Tempered
Door Handing
Left Hand/Outswing
Door Type
French Patio Door
Features
Argon Filled G1ass,Lockset Bore(Double Bore),Weatherstripping
Finish Type
Finished
Frame Material
Composite
Glass Type
Aug 24 2018 0323PM HP Fax page 10
Full Lite
Hinge Type
Ball Bearing
Included
Instructions
Material
Fiberglass
Product Weight(lb.)
240 lb
Returnable
90-Day
Warranty/Certifications
Energy Star Qualified
North-Central,Northem,South-Central,Southem
Manufacturer Warranty
Limited Lifetime
"One Installed in Kitchen to back patio.
Aug 24 2018 03:24PM HP Fax page 11
Specifications Anderson Series 200 Double Hung 'Window
35.5X56.5 Model # DH4039
Dimensions
Grid Width(in.)
None
Jamb Depth(in.)
4.5
Product Depth(in.)
4.5
Product Height(in.)
56.5
Product Width(in.)
35.5
Rough Opening Height(In.)
57
Rough Opening Width(In.)
36
Width(in.)x Height(in.)
35.5 x 56.5
Details
Exterior Color/Finish Family
White
Features
Paintable/Stainable,Tilt-In Cleaning
Frame Material
Wood
Glass Type
Low-E Glass
Glazing Type
Double-Pane
Grid Pattern
None
Hardware Color/Finish Family
White
Included
Hardware
Interior Color/Finish Family
White
Lock Type
Lock and Keeper/Spoon
Number of Locks
Aug 24 2018 03:24PM HP Fax page 12
1
Product Weight(lb.)
64.1?lb
Solar Heat Gain Coefficient
0.32
U-Factor
0.29
Window Use Type
New Construction
Warranty/Certifications
Energy Star Qualified
North-Central,South-Central,Southem
Manufacturer Warranty
20 year glass, 10 year transferable
**Two installed in Foyer
**Three installed in Living Room
**Two installed in Front Bedroom
**Two installed in Middle Bedroom
**Two installed in Master Bedroom
Aug 24 2018 03:24PM HP Fax page 13
Specifications Anderson Series 200 23.5X35.5 Double Hung
Window Model # DH2O30
Dimensions
Grid Width(in.)
None
Jamb Depth(in.)
4.5
Product Depth(in.)
4.5
Product Height(in.)
35.5
Product Width(in.)
23.5
Rough Opening Height(In.)
36
Rough Opening Width(hL)
24
Width(in.)x Height(in.)
23.5 x 35.5
Details
Exterior Color/Finish Family
White
Features
Paintable/Stainablejilt-In Cleaning
Frame Material
Wood
Glass Type
Low-E Glass
Glazing Type
Double-Pane
Grid Pattern
None
Hardware Color/Finish Family
White
Included
Hardware
Interior Color/Finish Family
White
Lock Type
Lock and Keeper/Spoon
Number of Locks
Aug 24 2018 0325PM HP Fax page 14
1
Product Weight(lb.)
31.51b
Solar Heat Gain Coefficient
0.32
U-Factor
0.29
Window Type
Double Hung
Window Use Type
New Construction
Warranty/Certifications
Energy Star Qualified
North-Central
Manufacturer Warranty
20 year glass, 10 year transferable
**Two of these are installed in the Dining Room
"Three of these are installed in the Living Room
"One of these is installed in the,Storage Loft
Aug 24 2018 0326PM HP Fax page 15
Specifications American Craftsman Sliding Window Series
70 Cellar Windows Model #70 Slider Buck
Dimensions
Grid Width(in.)
None
Jamb Depth(in.)
2.6875
Product Depth(in.)
4.
Product Height(in.)
19
Product width(in.)
31
Rough Opening Height(In.)
19.5
Rough Opening Width(In.)
31.5
Width(in.)x Height(in.)
31 x 19
Details
Exterior Color/Finish Family
White
Frame Material
vinyl
Glass Type
Low-E Glass
Glazing Type
Double-Pane
Grid Pattern
None
Hardware Color/Finish Family
White
Included
tlardware,Screen
Insect screen included
Yes
Interior Color/Finish Family
White
Lock Type
Cam Action
Locking
Aug 24 2018 0326PM HP Fax page 16
Yes
Number of Locks
1
Privacy glass
No
Product Weight(lb.)
201b
Returnable
90-Day
Solar Heat Gain Coefficient
0.24
Tinted glass
No
U-Factor
0.3
Window Handing
Universal/Reversible
Window Type
Sliding Window
Window Use Type
Replacement
Warranty/Certifications
Energy Star Qualified
North-Central,Northern,South-Central,Southern
Manufacturer Warranty
Limited Lifetime Warranty
'There are 5 of these windows installed in the Basement.
Aug 24 2018 03:27PM HP Fax page 17
Specifications Anderson 400 Series Casement Window
Model CN235LR
Dimensions
Grid Width(in.)
None
Jamb Depth(in.)
2.875
Product Depth(in.)
4.188
Product Height(in.)
40.813
Product Width(in.)
40.75
Rough Opening Height(In.)
41.38
Rough Opening Width(In.)
41.25
Width(in.)x Height(in.)
40.75 x 40.813
Details
Exterior Color/Finish Family
White
Features
Paintable/Stainable
Frame Material
Wood
Glass Type
Low-E Glass
Glazing Type
Double-Pane
Grid Pattern
None
Hardware Color/Finish Family
White
Included
Hardware
Interior Color/Finish Family
Unfinished Wood
Lock Type
Multi-Point Single Actuator
Aug 24 2018 03:27PM HP Fax page 18
Number of Locks
2
Product Weight(lb.)
581b
Solar Heat Gain Coefficient
0.32
U-Factor
0.28
Window Use Type
New Constrnction,Replacement
Warranty/Certfficatlons
Energy Star Qualified
North-Central,Northern,South-Central,Southern
Manufacturer Warranty
20 Year Glass, 10 Year Limited
'�**There are four of these installed in the kitchen
Aug 24 2018 0328PM HP Fax page 19
Specifications Anderson 440 Awning Window Model A31V
Dimensions
Grid Width(in.)
None
Jamb Depth(in.)
2.875
Product Depth(in.)
4.188
Product Height(in.)
24.125
Product Width(in.)
35.938
Rough Opening Height(In.)
25
Rough Opening Width(In.)
36.5
Width(in.)x Height(in.)
35.938 x 24.125
Details
Color
White
Color Family
White
Exterior Color/Finish Family
White
Features
Paintable/Stainable,Venting
Frame Material
Composite
Glass Type
Low-E Glass
Glazing Type
Double-Pane
Grid Pattern
None
Hardware Color/Finish Family
Black
Included
Hardware
Insect screen included
No
Interior Color/Finish Family
Aug 24 2018 03:29PM HP Fax page 20
Unfinished Wood
Lock Type
Multi-Point Single Actuator
Locking
Yes
Number of Locks
1
Product Weight(1b.)
281b
Solar Heat Gain Coefficient
0.31
U-Factor
0.28
Window Use Type
New ConstructionAeplacement
Warranty/Certifications
Energy Star Qualified
North-Cental,Northern,South-Central,Southern
Manufacturer Warranty
20 Year glass, 10 year limited
"One installed in the Front Bedroom
"*Two installed in the Master Bedroom
Aug 24 2018 03,30PM HP Fax page 21
.t
Specifications American Craftsman Model 2838786 Double
Hung Window 70 Series
Dimensions
Grid Width(in.)
None
Jamb Depth (in.)
3.25
Product Depth(in.)
4.5
Product Height(in.)
37.25
Product Width(in.)
27.75
Rough Opening Height(In.)
38
Rough Opening Width(In.)
28
Width(in.)x Height(in.)
27.75 x 37.25
Details
Exterior Color/Finish Family
White
Features
Tilt-In Cleaning
Frame Material
Vinyl
Glass Type
Low-E Glass
Glazing Type
Double-Pane
Grid Pattern
None
Hardware Color/Finish Family
White
Included
Hardware,Screen
Interior Color/Finish Family
White
Lock Type
Multi-Point Single Actuator
Number of Locks
Aug 24 2018 03,31 PM HP Fax page 22
P
2
Product Weight(lb.)
261b
Returnable
90-Day
Solar Heat Gain Coefficient
0.25
U-Factor
0.29
Window Type
Double Hung
Window Use Type
Replacement
Warranty/Certifications
E�igrgy Star Qualifier
North-Central,South-Centrai,Southern
Manufacturer Warranty
Limited Lifetime Warranty
"*There is one of these installed in the Master Bath
HORTON RESIDENCE
1645 WESTPHALIA RD.
MATTITUCK N.Y.
EXIST. RESIDENCE EXISTING: SINGLE FAMILY RESIDENCE
APPROVED AS DOTED V' ��}R SCTM# 1000- 141 -01-6
REPLACE 2ND FL. DOOR W/ WINDOW ZONE R-40 .5 ACRES
DATE: B.P.`# �' US l I
- PROPOSED:
--- --- -- FEE: � l' By; �� WITr , /t T[�- EXIST. WOOD ACCESS RAMP WAS REMOVED AND
-"--�- -
-- _------------ ---- - NOTIFY BUILDING DEPAR T AT [ NEW 395 SQ.FT. DECK WAS BUILT ON REAR OF
-----_.__- 765-1802 8 AM TO 4 PM FOR THE OF OL
FOLLOWINEXIST. RESIDENCE.
-- ------- - - - G INSPECTIONS: ROOF WAS ADDED OVER DECK AND THE CENTER
___-------------------"..
I. FOUNDATION - TWO REQUIRED
SECTION OF THE ROOF WAS INTENDED TO BE A
- --- ""_--"- FOR POURED CONCRETE OCCUPANCY OR ROOF DECK ACCESSIBLE FROM A DOOR ON THE
- -- - - ------
EXIST. SLOPED ROOF W/ -EXIST. SLOPED ROOF W/ 2• ROUGH = FRAMING & PLUMBING
ASPHALT SHINGLES ASPHALT SHINGLES- 3. INSULATION USE IS UNLAWFUL 2ND FL. THIS WORK WAS NEVER COMPLETED.
-__ PARTIALLY UILT FLAT ROO DECK TO BE - 4, FINAL •CONSTRUCTION MUST l�""r' PROPOSED WORK IS TO REPLACE DOOR WITH A
CONVERTED O SLOPED, HINGLED ROOF _ _ WITHOUT CERTIF A I l.. WINDOW OF SAME SIZE AND ADD NEW RAFTERS
TO MATCH EX T. ""---_------ ----- BE COMPLETE FOR C.O.
_ --- -.--.. ALL CONSTRUCTION SHALL MEET' THE
OF OCCUPANCY IN CENTER SECTION THEREBY ELIMINATING THE
r�ld ADD NEW ASPH T/FI RGLA SHINGLES - - --
� -------_._--_ TO ALL OF ROOF A --- -- -- {.
--
REQUIREMENTS OF THE CODES OF NEW HALF-BUILT ROOF DECK.
-------_ - YORK STATE. NOT RESPONSIBLE FOR
-- DESIGN OR CONSTRUCTION ERRORS. GENERAL NOTES
- - 1. All work shall conform to the requirements of the Residential Code of New York
State, County and Town Department Regulations, Utility Company requirements and
Additional best trade practises.
----- --- --- -- --------- -,-- - -- tt 2. Before commencing work the Contractor shall file all documents required by the
- -- _- ---- COMPLY WITH ALL CODES OF Certification Building Department, pay all fees required by local agencies and obtain all required
permits.
NEW YORK STATE & TOWN CODES May Be Required. c The Contractor shall visit the site and verify all dimensions and the existing
conditions affecting the work prior to construction. Any discrepancies which would
interf
re
c.mleeion of the wok decribed
rin
_ _ _ _ _ _ _ AS REQUIRE ONS OF reported to the architectcorrypoperrttytotwner. Do notrstarrtswork untile such clonbditions
--
- ,, D AND CONDITIONS
- -- - -- ---- - - - -
-- - - - - - -- - - - - - -- - - -- -- -- -- -- -- --- - - -- - - - -- - - - have been examined and a course of action mutually agreed upon. Failure to notify
Jv w the owner or architect of unsatisfactory conditions will be construed as an acceptance
1 of the conditions to properly perform the required work.
10 T1 ; ; Q 4. All work is to conform to the drawings and specifications of the architect and
engineer consultants.
��EES 5. The Contractor is to maintain a complete and up to date set of plans on the
job site at all times
6. The drawings are not to be scaled under any circumstances.
RETAIN STORM WATER RUNOFF 7. It shall be the Contractor's responsibility to ascertain all prevailing procedures
25'-6" PURSUANT TO CHAPTER 236 including storage and toilet facilities,protection of existing work to remain,access to
ROOF PLAN y work area, hours of permitted work,availability of water and electric power and all
p OF THE TOWN CODE. other conditions and restrictions for this particular location in order to execute the
1 /4" = 1'-Orr 5.2 8. 18 work in a careful and orderly manner with the least possible disturbance to the public.
8. The Contractor shall make the neccesary arrangements to utilities and services
temporarily disconnected while performing the work as required.
9. The Contractor shall provide all dimensions and cut-outs for other trades.
10. The Contractor shall provide proper shoring and bracing for all remaining structure
prior to removal of existing structure
]EXIST- ICUSE 11. Plumbing, electrical, HVAC and similar work shall be performed by licensed
TAt1t� ��F�.F�LI i�I 1di.�.7 f��VtU��Y.D ROOF RAMIO JG persons who shall arrange for and obtain all required inspections.The General
,:'�3( Y 1� f� V NO CH NGES Contractor shall be responsible for scheduling all other inspections as required.
12. The Contractor is solely responsible for construction safety and shall hold the
owner and architect harmless from litigation arising out of the Contractor's failure to
provide construction safety means and methods.
REPLACE EXIST. EXTERIOR DOOR W/ WINDOW
EXIST. RESIDENCE SIZ:_D TO FIT EXIST. HEADER & JACK STUDS CONSTRUCTION NOTES
ADD NEW EXTERIOR WALL BELOW NEW WINDOW
ADD NEW 2X10 LEDGER BOLTED TO HOUSE FRAME
NO CHANGES TO 1ST WI 1. All footings shall rest on undisturbed soil at a minimum of 36" below fin. rade.
REPLACE 2ND FL. DOOR W/ WINDOW W/ 3/8" BOLTS STAGGERED @ 16" OC g g
ADD NEW 2X6 @ 16" OC ROOF RAFTERS 2. Poured concrete shall have a minimum psi of 2800 at 28 days unless noted.
� � �, , / . TECO TO LEDGER 3. Sill plates shall be preserved, treated wood and be installed above a 16 oz.
NEIN ASPHALT/ FIBERGLASS SHINGLES & copper termite sheitd.
j ADD NEW 2X10 LEDGERBOLTED TO HOUSE FRAME j ROOFING FELT ON ALL ROOF SURFACE 4. Shingle siding shall conform to ASTM D 3679 and be installed in accordance
IN AREA TO BE CONVERTED TO SLOPED ROOF NEW 1/2" PLYWD. SHEATHING @ NEW ROOF with the New York State Building Code and manufacturers specifications.
O 2'-0" WIDE x 3/4" THICK PLYWD. GUSSET 5. Pilings shall be installed by a licensed contractor to a depth and bearing agreed
NEW 2 4 STUDS @ 16" OC
O upon by an engineer and certificates shall be issued stating same.
io o I SCREWED & GLUED TO BOTH SIDES OF BELOW NEW WINDOW
6. Unless otherwise noted all framing and structural wood components shall be
Lu EACH RAFTER TYP. 112" GYP. BD. @ INT. #2 or better Douglas Fir.
LL I 1/2" S EATHING @ EXT.
X
Q r 7. All framing techniques and methods shall be as prescriptive design based on
> w N o ! > w TYVEK HOUSE WRAP. AF&P Wood Frame Construction Manual for One and two Family Dwellings (WFCM)
O > LL O > R-15 ATT INSUL. or as specified in R301.2.1.1
j� m 0 w 0 m 0 ADD 2X6 TRUSS p
Q co z 0 ¢ Q 8. All building envelope components shall comply with Chapter 6 of the Energy
Lu L? L) p I w c? SOFFIT & TRIM TO MATCH EXIST7FADE Conservation Code of the State of New York.
m O o m ! a ¢ 0e O o NEW RAFTERS TO BE STRAPPED 2X6 @ EACH CEIL. JOIST TO EXIST. & NEW ROOF RAFTERS 9. Fireblocking shall be provided in all wood framed construction in accordance
n _ w EXIST. 2-2X8 ACU DECK GIRDER FASTENED TO w EXIST. GIRDER
p o F CREATE TRUSS with NYS Code R 602.8 to form an effective fire barrier between stories and
cn i EXIST. 6X6 POSTS ANCHORED TO I ST 2-2X10 GIRDER W/ 3/4" PLYWD. FL. PL. - NO CHANGES between the top story and roof space.
@' @ O 12" DIA CONC. FTGS. @ @ ST. 6X6 POSTS ANCHORED TO EXIST. 12" CONC. PIERS 10. Protective panels shall be provided for glazed openings in accordance with
36" BELOW GRADE
� Z /� _ Il z � omtu NYS code R301.2.1.2 if they are required.
o p LL w i { \r�/ w ! o pK07 11. All portions of the new structure are designed to comply with local geographic
LL
O < 0 �I ( U O O < and climatic criteria as stated in the following table.
p nx j EXIST. 2X8 @ 16" OC CEIL. JOISTS @ 16" OC ABOVE nX ! p
U 0 M (FASTENED TO EXIST. 3-2X8 GIRDERS W/ TECOS ° w 0 GEOGRAPHIC & CLIMATE DESIGN CRITERIA
(AT UNFINISHED ROOF DECK THAT WILL BE CONVERTED - I @ o0 0o EXIST. 5/4x6 WOOD DECKING
°x° °x° u~ n x x GROUND SNOW LOAD 45 ps1
EXIST. 2X8 DECK JOISTS TECO TO
X N N X TO NEW SLOPED ROOF W/ NO DECK)I x X N SEISMICWIND PDE9IGN CATATGORY 1830 MPH
n� N Z Z u w I N Z O EXIST 2-2X8 DECK GIRDERS ANCHORED TO WEATHERING SEVERE
F t- I F F EXIST. 12" DIA. CONC. PIERS
j�
U) U) I I L Co V) 2x8 LEDGER BOARD
X x x EXIST. 2-2X10 W/ 1/2" PLYWD. FL PL ROOF GIRDER ABOVE x x x FROST LINE DEPTH 36"
Li w w I I I I I I I I I I I I I I I I I I I w w w ANCHORED BOLTS @ 16" HOUSE W/ 1/2" DIA. TO HEAVY
I " OC STAGGERED. DECAY TERMITE THREAT SLIGHT R TO MODERATE
EXIST. 2-2X8 ACQ DECK GIRDER FASTENED TO N WINTER DESIGN TEMPERATURE 11
EXIST. 6X6 POSTS ANCHORED TO
12" DIA CONC. FTGS. FLOOD HAZARD AS NOTED
U L
- - - - - - -
La�gLl lI�zLls. -7- - _ - - - - -
PLANS & SECTION
7'-04" 8'-102" SCALE AS NOTED MAY 26, 2018
25'-6" r NEWT -) ress
DECK PLAN SECTION # 1
A O 1START[
1 /4" = 1'-0" 5.2 8. 18 1 /4" = 1'-0" 5.2 8. 18permits drattin ex editin 1 OF 1
cm ? w
<G `•,_,^. ° ? PO BOX 49
JOAN CHAMBERS SOUTHOLD NY 11971
631-294-4241
/' E SS'�N
NORTON RES D CFS
1645
MATTITUCK N.Y.
EXISTING: SINGLE FAMILY RESIDENCE
SCTM# 1000-141-01-6
ZONE R-40 .50 ACRES
34-1/2" x
46-1/2" D.H.
PROPOSED:
ADDITION OF SINK AND TOILET TO EXIST.
LAUNDRY ROOM. ASLO ADDITION OF,
SHOWER TO EXISTING MASTER BATH.
30-1/2" x 30-1/2" x
34-1/2 x 34-1/2" x 56" D.H. 56" D.H.
46-1/2" D.H. 46-1/2" D.H.
� I 15'-52»
O.,
+ STORAGE LOFT ABOVE EXISTING PROPOSED
4, 1ST FL. 900 SQ. FT. 900 SQ. FT:
2ND FL, 729 SQ. FT. 729 SQ. FT.
Cn N 0
T BEDROOM 3 N z
Ig U) I Q
1D@)Do° o o N GENERAL NOTES
LIVING ROOM X 1. All work shall conform to the requirements of the Residental Code of New York
Stale, County and Town Department Regulations, Utility Company requirements and
�p N best trade practises.
00
N O 2. Before commencing work the Contractor shall file all documents required by the
M Building Department, pay all fees required by local agencies and obtain all required
permits.
3. The Contractor shall visit the site and verify all dimensions and the existing
conditions affecting the work prior to construction. Any discrepancies which would
DOWN RIs• interfere with the satisfactory completetion of the work described herein shall be
8-1 2" reported to the architect or property owner. Do not start work until such conditions
have been examined and a course of action mutually agreed upon. Failure to notify
30-1/2" x the owner or architect of unsatisfactory conditions will be construed as an acceptance
56" D.H. of the conditions to properly perform the required work.
4. All work is to conform to the drawings and specifications of the architect and
ti engineer consultants.
}O 5. The Contractor is to maintain a complete and up to date set of plans on the
O•, job site at all times
•��! "I"80 6. The drawings are not to be scaled under any circumstances.
.0 = 7. It shall be the Contractor's responsibility to ascertain all prevailing procedures
6 WALK-IN CLOSET including storage and toilet facilities,protection of existing work to remain access to
work area, hours of permitted work,avai lability of water and electric power and all
a other conddions and restrictions for this particular location in order to execute the
xL work in a careful and orderly manner with the least possible disturbance to the public.
8. The Contractor shalt make the neccesary arrangements to utilities and services
�O•• temporarily disconnected while performing the work as required.
+80" 9. The Contractor shall provide all dimensions and cut-outs for other trades.
p X 10. The Contractor shall provide proper shoring and bracing for all remaining structure
LL �r 7" r� prior to removal of existing structure.
'n o BEDROOM 2 O x 11. Plumbing, electrical, HVAC and similar work shall be performed by licensed
a' persons who shall arrange for and obtain all required inspections.The General
X DINING ROOMx Contractor shall be responsible for scheduling all other inspections as required.
12. The Contractor is solely responsible for construction safety and shall hold the
Nv N �p owner and architect harmless from litigation arising out of the Contractor's failure to
x
provide construction safety means and methods.
N CONSTRUCTION NOTES
1. All footings shall rest on undisturbed soil at a minimum of 36" below fin, grade.
+Q 2. Poured concrete shall have a minimum psi of 2800 at 28 days unless noted.
3. Sill plates shall be preserved, treated wood and be installed above a 16 oz.
copper termite sheild.
4. Shingle siding shall conform to ASTM D 3679 and be installed in accordance
with the New York State Building Code and manufacturers specifications.
p` + 5. Pilings shall be installed by a licensed contractor to a depth and bearing agreed
^off ji upon by an engineer and certificates shall be issued stating same.
Z ;; � 6. Unless otherwise noted all framing and structural wood components shall be
O d.; #2 or better Douglas Fir.
Q Q 7 All framing techniques and methods shall be as prescriptive design based on
v U v = AF&P Wood Frame Construction Manual for One and two Family Dwellings (WFCM)
X N 0
Zipor as specified in R301.2.1.1
iv t X 8. All building envelope components shall comply with Chapter 6 of the Energy
N x a. Conservation Code of the State of New York.
N 9. Fireblocking shall be provided in all wood framed construction in accordance
N N O x with NYS Code R 602.8 to form an effective fire barrier between stories and
N O
N between the top story and roof space.
X 10. Protective panels shall be provided for glazed openings in accordance with
LL O NYS code R301.2 1.2 if they are required.
KITCHEN � ' MASTER BEDROOM 11. All portions of the new structure are designed to comply with local geographic
•-5•• and climatic criteria as staled in the following table.
/✓ x
o GEOGRAPHIC & CLIMATE DESIGN CRITERIA
_ Ln _
GROUND SNOW LOAD 45 pst
Q WIND SPEED 130 MPH
U O SEISMIC DESIGN CATATGORY B
LO
WEATHERING SEVERE
x FROST LINE DEPTH 36"
+�O TERMITE THREAT MODERATE TO HEAVY
X DECAY SLIGHT TO MODERATE
M
WINTER DESIGN TEMPERATURE 11
WD O O FLOOD HAZARD AS NOTED
14'-102"
Z wwmz�4
36" x 50" D.H. NEW 31" x 47" x 46" SLID. A-101 1ST AND 2ND FLOOR PLANS
46" x 22" FIXED 34" x 34" SLID. 6'-0" FRENCH DOORS 36" D.H.
FLOORPLANS
SCA JULY 13TH 2018
1 °� * A 1 0 1
AUG 1 5 2018LU
SECOND FLOOR PLAN r'•.-.� �::. 1 OF 1
FIRST FLOOR PLAN r, V-0" �'° ��• ��
,. p ���'p Po Box 4s
ROBERT WILS
SOUTHOLD NY 11971
631-294-4241
NORTONRESIDENCE
1645 A 4 _ �
MATTITUCK N.Y.
EXISTING: SINGLE FAMILY RESIDENCE
�- L SCTM# 1000-141-01-6
�E� f �'��� ZONE R-40 .50 ACRES
34-1/2 x
46-1/2° D.H. T :'' - PROPOSED:
ADDITION OF SINK AND TOILET TO EXIST.
11 LD LAUNDRY ROOM. ASLO ADDITION OF
SHOWER TO EXISTING MASTER BATH.
EXISTING WINDOWS REPLACED WITH NEW
ANDERSEN 200 SERIES WINDOWS.
30-1/2" x 30-1/2" x
34-1/2 x 34-1/2" x 56" D.H. 56" D.H.
46-1/2" D.H. 46-1/2" D.H.
15'-52
O•,
CLOSET +�� EXISTING PROPOSED
�0 1ST FL. 900 SQ. FT. 900 SQ. FT.
0 2ND FL. 729 SQ. FT. 729 SQ. FT.
U)N o STORAGE LOFT ABOVE
BEDR OM 3 N
00 I J ? (n Y aQ
V/ N GENERAL NOTES
LIVING ROOM O N t�0 x 1. All work shall conform to the requirements of the Residenlal Code of New Yo
State, County and Town Department Regulations, Utility Company requirements and
N best trade practises.
N O 2. Before commencing work the Contractor shall file all documents required by th
r Building Department, pay all fees required by local agencies and obtain all requirer
M
permits.
0 3 The Contractor shall visit the site and verify all dimensions and the existing
OWN RIS. conditions affecling the work prior to construction. Any discrepancies which would
interfere with the satisfactory compleletion of the work described herein shall be
8_-1 2" reported to the architect or property owner. Do not start work until such condition
CLOSET have been examined and a course of action mutually agreed upon. Failure to no'
30-1/2" x the owner or architect of unsatisfactory conditions will be construed as an acceptar
56" D.H. of the conditions to properly perform the required work.
4. All work is to conform to the drawings and specifications of the architect and
,y engineer consultants
5. The Contractor is to maintain a complete and up to date set of plans on the
O job site at all times
3.
•�— -f-rp 6 The drawings are not to be scaled under any circumstances.
try 2 O'' 7. It shall be the Conh act I responsibility to ascertain all prevailing procedures
WALK-IN CLOSET including storage and toilet facilities,protection of existing work to remain,access to
SIN work area, hours of permitted work,availability of water and electric power and all
other conditions and restrictions for this particular location in order to execute the
x work in a careful and orderly manner with the least possible disturbance to the fou
8 The Contractor shall mage the neccesary arrangements to utilities and service=
temporarily disconnected white performing the work as required.
9 The Contractor shall provide all dimensions and cul-outs for other trades
2 X O" 10. The Contractor shall provide proper shoring and bracing for all remaining strut
O ILL .-� prior to removal of existing structure.
BEDROOM 2 O x 11. Plumbing, electrical, HVAC and similar work shall be performed by licensed
rj d, Q persons who shall arrange for and obtain all required inspections.The General
x -� Contractor shall be responsible for scheduling all other inspections as required.
FOYER DINING ROOM " �o M 12. The Contractor is solely responsible for construction safety and shall hold the
owner r v N r'u0+ andarchitect
harmless from
amethods
litigation ring out of the Contractors failure ti
provide tionsafelymea
N x
eo CONSTRUCTION NOTES
Sz jrt 1. All footings shall rest on undisturbed soil at a minimum of 36" below fin. grad
2 Poured concrete shall have a minimum psi of 2800 at 28 days unless noted
ti a 3. Sill plates shall be preserved, treated wood and be installed above a 16 oz.
copper termite sheild.
4. Shingle siding shall conform to ASTM D 3679 and be installed in accordance
with the New York Stale Building Code and manufacturers specifications.
5. Pilings shall be installed by a licensed contractor to a depth and bearing agree
upon by an engineer and certificates shall be, issued stating same.
6. Unless otherwise noted all framing and structural wood components shall be
Q r50 •+;� �. #2 or better Douglas Fir.
Q 7. All framing techniques and methods shall be as prescriptive design based on
io U 2 AF&P Wood Frame Construction Manual for One and two Family Dwellings (WFCI
N O or asspecified in R301.2 1.1
X UJ N
8. All budding envelope components shall comply with Chapter 6 of the Energy
X
N x _ Conservation Code of the State of New York.
N N x 9. Fireblocking shall be provided in all wood framed construction in accordance
N N O wish NYS Code R 602.8 to form an effective fire barrier between stories and
N
� between the top story and roof space
X N
10. Protective panels shall be provided for glazed openings in accordance with
LL `I IJYS code R301.2.1 2 if they are required
KITCHEN MASTER BEDROOM 11. All portions of the new structure are designed to comply with local geograpl
.-5.. and climatic criteria as stated in the following table.
X
o GEOGRAPHIC & CLIMATE DESIGN CRITERIA
GROUND SNOW LOAD 45 p:
WIND SPEED 130 1
Q O SEISMIC DESIGIi CATATGORY B
U to WEATHERING SEV
X FROST LINE DEPTH 36"
v O TERMITE THREAT MODERATE TO HE.
x M t� DECAY SLIGHT TO MODER
^�O WAITER DESIGN TEMPERATURE 11
N FLOOD HAZARD AS NO
W D p p 14'-102.'
36" x 50" D.H. NEW 31" x 47" x 46" SLID. A-101 1ST AND 2ND FLOOR PLANS
46" x 22" FIXED 34" x 34" SLID. 6'-0" FRENCH DOORS 36" D.H.
FLOORPLANS
SCALE AS NOTED JULY 13TH 20'
�oF N�wr A
E Cy O 101
1 OF 1
SECOND FLOOR PLAN m w
FIRST FLOOR PLAN 1 /4" = 11
PO
1 /4" = 1'-0" �
A 5 0 B 9
T WILSON SOUTHHOLDNY 1197'.
RAF i� 631-294-4241