Loading...
HomeMy WebLinkAbout41667-Z � g�1FF01/r G� Town of Southold 9/24/2018 P.O.Box 1179 53095 Main Rd p4. �4�g Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39918 Date: 9/24/2018 THIS CERTIFIES that the building WIRELESS COMMUNICATION SYSTEMS Location of Property: 40200 Route 25, Orient SCTM#: 473889 Sec/Block/Lot: 15.-9-8.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/29/2017 pursuant to which Building Permit No. 41667 dated 5/25/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: wireless pole extension co-location and related equipment as applied for per ZBA#7023 dated 2/16/2017 and Planning Board for Verizon. The certificate is issued to Mgh Enterprises Inc of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 41667 1/24/2018 PLUMBERS CERTIFICATION DATED A thotTed ignature TOWN OF SOUTHOLD BUILDING DEPARTMENT C2 me TOWN CLERK'S OFFICE o . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41667 Date: 5/25/2017 Permission is hereby granted to: Mgh Enterprises Inc PO BOX 333 Orient, NY 11957 To: construct a pole extension, co-location and related equipment as applied for per ZBA and Planning approvals. Verizon. At premises located at: 40200 Route 25, Orient SCTM # 473889 Sec/Block/Lot# 15.-9-8.1 f'JbV- Pursuant to application dated -44040+7 and approved by the Building Inspector. To expire on 11/24/2018. Fees: WIRELESS COMMUNICATIONS -MODIFICATIONS $500.00 CO -COMMER $50.00 To 1: $550.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy -Residential$15.00, Commercial$15.00 Date. 5/19/17 New Construction: X Old or Pre-existing Building: (check one) Location of Property: 40200 Main Road Orient House No. Street Hamlet Owner or Owners of Property: M.G.H. Enterprises, Inc. Suffolk County Tax Map No 1000, Section 15 Block 9 Lot 8.1 Subdivision Filed Map. Lot: New York SMSA Limited Partnership Permit No. Date of Permit. Applicant:d/b/a Verizon Wireless Health Dept. Approval: Underwriters Approval: Planning Board Approval: 4/11/17 Request for: Temporary Certificate Final Certificate: X (check one) New York SMSA Limited Partnership Fee Submitted: $ 50.00 d/b/a Veriz W le s Applicant Signature Name. John Walden Title: Senior Engineer - Equipment o��OF SOUlyol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road N Fax(631)765-9502 P.O.Box 1179 �Q roger.richertR-town.southoId.ny.us Southold,NY 11971-0959 O couffm BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Mgh Enterprises (Verizon Wireless) Address: 40200 Route 25 city:Orient st: New York zip: 11957 Building Permit#: 41667 Section: 15 Block. 9 Lot- 8.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: B&D Electical License No: 41611-ME SITE DETAILS Office Use Only Residential Indoor Basement Service Only Commerical X Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph 200A Heat Duplec Recpt Ceding Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency FixtureTime Clocks Disconnect 200A Switches Twist Lock Exit Fixtures TVSS Other Equipment: 200A Underground Service to Verizon Cell Site to Include All Electrical Equipment on Cell Site/Tower. Notes: Inspector Signature: -�`� Date: January 24, 2018 0-Cert Electrical Compliance Form.xis Olaf so H �o� olo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION E - FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS. t�ft 4e(, ,Qlfccao��-- - C DATE o INSPECTOR a SOUIyo TOWN OF SOUTHOLD BUILDING DEPT. 765-1602 INSPECTION [ ] UNDATION 1ST [ ] ROUGH PLEIG. [ FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRI AL (FINAL) REMARKS: P/WR,/ ✓ �l/lJ� � mI r 0� UZAN4 IS ' DATE INSPECTOR souTyo courm,N�' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: Op thv(/ P�*nvq" 15 64tz 4y �. CZ vo ID Av o DATE cel D INSPECTOR aOF SO�ryolo l5 ' courm,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE,SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) REMARKS: Z. —'711iit r DATE 1 7 G INSPECTOR 1 i i i i I T E C T S IPamirs Steven R Samntero,AIA, May 4,2018 Ned A MacDonald,AIA, Eldon W.Smith,ATA i Robert F.H".—h,AIA _,,,� rs,Emer¢us Will ; D l _ �'>,-/' i–'.�•I Wlliam R. AIA Town of Southold } LLL 111 V i Thoinaa R Turkel,Turkel,AIA � f atm 53095 Route 25 Christopher M,Cmns,AIA,NCARB Southold, NY 11971 SEP 1 7 2018 i 1 Re: New York SMSA Limited Partnership RUM, DY.\TC-DEPT. I j d/b/a Verizon Wireless <; .,a ;FCiLTHOLD Site Name:Orient Point 2 I 40200 Main Road j Orient, NY Tax ID:District 1000/Sec.15/Blk.9/Lot 8.1 WFC Project No.: 14-10823 a I To Whom It May Concern: { William F.Collins,AIA Architects LLP(WFC)visited the above referenced site on 11/2/17 and reviewed } the photographic documentation of the completed wireless telecommunications facility and find all I work to be in accordance with the construction drawings approved by the Town of Southold on May ! 23, 2017 and the Building Code of New York State. An electrician's certificate of electrical inspection shall be issued concurrently with this letter by others. i We trust the foregoing provides the information you have requested. If you have any questions, please do not hesitate to contact our office. r I Very truly yoy.r % Neil A. M Lftfl lL,�Af1 LtED AP Partner I i Cc: Mariana Turturro(Amato Law Group PLLC), Kenny Uhll(All Points/Verizon Wireless) 1) 1 TF C HNOI_OGY DRIVE EAST SE:-AUKE f NY 1 1/3,1 11H 631 689.8450 FAX.63 1 680-8.159 WWW WFCAIA COM WV s- STATE • /c 1 �► a • • / I pm TAU RIMA MMMET" 1". I UA nal �. IF t .r = TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX: (631) 765-9502 / -- �i Survey SoutholdTown.NorthFork.net PERMIT NO. (f Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined ,20 Single&Separate Storm-Water Assessment Form 2 I et: Denise J. Vista, Esq. Approved ,2 it to:Amato Law Group, PLLC Disapproved a/c 6 6 Old Country Road, Suite 901 11 CRY, Imu t 11530 — Phone:(516)227-6363 Expiration 920 Bui i s ect APPLICATION FOR BUIL NG PERMIT "! Date April 29 , 2016 �� INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Bui Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public stree s r_,_, areas, and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. NewYo S A Li d Partership d/b/a Venzon Wireless B : Y"4� (Signatur of applicant or name,if a corporation) c/o ato Law Group,PLLC 666 Old Country Road,Suite 901 Garden City,New York 11530 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Applicant is lessee of property Name of owner of premises M.G.H. Enterprises, Inc. (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 40200 Main Road Orient House Number Street Hamlet County Tax Map No. 1000 Section 15 Block 9 Lot 8.1 �f Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Marina, restaurant, and wireless communications facility b. Intended use and occupancy Same, and proposed wireless facility 3. Nature of work(check which applicable):New Building Addition Alteration X Repair Removal Demolition Other Work public utility wireless communications facility (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units n/a Number of dwelling units on each floor n/a If garage, number of cars n/a Marina/public utility wireless 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. communications facility tower 7. Dimensions of existing ximsht= if any: Front N/A Rear N/A Depth N/A Height 69'-0" agl Number of Stories N/A tower Dimensions of same_is*ntm with alterations or additions: Front N/A Rear N/A Depth Height 89,-O'rragl Number of Stories N/A (equipmentccorupound) Length Width 8. Dimensions of entire new construction:: 131-10" IRW 32'-0" Depth Height 13, Number of Stories 9. Size of lot: Front Rear Depth Area: 4.7 acres 10. Date of Purchase Name of Former Owner Applicant is lessee of property 11. Zone or use district in which premises are situated Marine II zoning district 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO X 13. Will lot be re-graded? YES NO X Will excess fill be removed from premises?YES NO 40200 Main Road 14.Names of Owner of premises M.G.H. Enterprises Address orient,NY 11957 Phone No.(631)323-2424 Name of Architect WFC Architects Address 12-1 Technology drive Phone No (631)689-8450 Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES X NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES X NO * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? *YES X NO * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Nassau ) John Walden on behalf of New York SMSA Limited Partnership d/b/a Verizon Wireless being duly sworn,deposes and says that"he is the applicant (Name of individual signing contract) above named, (1)Heisthe Senior Engineer-Equipment (Contractor,Agent,Corporate Officer,etc.) 10Cdb?Z.4&XXXXc34i:fr2l,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of 2016 New York SM L'mite P rtnership d/b/a Verizon Wireless B : Z_L Notary Public Signature of Applicant Name:J Walden Title: Senior Engineer-Equipment TOWN OF SOUTHOLD FORM NO. 3 NOTICE OF DISAPPROVAL DATE: May 23, 2016 TO: ' Amato Law Group, PLLC (Verizon Wireless) 666 Old Country Road, Suite 901 Garden City, NY 11530 Please take notice that your application dated April 29, 2016 For permit for a co-location on an existing wireless facility at Location of property: 40200 Route 25, Orient,NY County Tax Map No. 1000- Section 15 Block 9 Lot 8.1 Is returned herewith and disapproved on the following grounds: The proposed co-location is permitted pursuant to site plan approval from the Southold Planning Board. /IC0d orized i n CC: file, planning Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. TOWN OF SOUTHOLD FORM NO. 3 NOTICE OF DISAPPROVAL DATE: May 23, 2016 AMENDED: August 24, 2016 TO: Amato Law Group, PLLC (Verizon Wireless) 666 Old Country Road, Suite 901 Garden City, NY 11530 Please take notice that your application dated April 29, 2016 For permit for a co-location on an existing wireless facility at Location of property: 40200 Route 25, Orient,NY County Tax Map No. 1000- Section 15 Block 9 Lot 8.1 Is returned herewith and disapproved on the following grounds: The proposed co-location is permitted pursuant to site plan approval from the Southold Planning Board. Furthermore, the associated accessory quipment is not permitted pursuant to Article XIII, Section 280-55, C. (1), which states that the equipment is "subject to the conditions of§ 280-15 thereof" which states that, on properties measuring more than 80,000 square feet in total size the minimum setback is 25 feet. According to the proposal, the equipment will have a setback of 7.5 feet. This Notice was amended on August 24, 2016 to address the need for a variance from the Zoning Board of Appeals. utho " e Signature CC: file, planning, z a Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. TOWN OF SOUTHOLD FORM NO. 3 NOTICE OF DISAPPROVAL DATE: May 23, 2016 AMENDED: August 24, 2016 RENEWED &AMENDED: October 18, 2016 TO: Amato Law Group, PLLC (Verizon Wireless) 666 Old Country Road, Suite 901 Garden City, NY 11530 Please take notice that your application dated April 29, 2016 For permit for a co-location on an existing wireless facility at Location of property: 40200 Route 25, Orient,NY County Tax Map No. 1000 - Section 15 Block 9 Lot 8.1 Is returned herewith and disapproved on the following grounds: The proposed co-location is permitted pursuant to site plan approval from the Southold Planning Board. Furthermore, the associated accessory equipment is not permitted pursuant to Article XIII, Section 280-56, which states, "No building shall be used and no building or part thereof shall be erected or altered in the MII District unless the same conforms to the Bulk Schedule and Parking and Loading Schedules incorporated into this chapter by reference,with the same force and effect if such regulations were set forth herein in full." Bulk Schedule requires a minimum side yard setback of 25 feet Accordingto o the proposal, the equipment will have a setback of 7.3 feet. This Notice was amended on August 24, 2016 to address the need for a variance from the Zoning ar o 7ed d further amended on October 18 2016 to correct errors. A ' ). / z— iognatur CC: file, planning, zba Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. td(� BOARD MEMBERS SOF S01 Southold Town Hall Leslie Kanes Weisman,Chairperson ��� OHO 53095 Main Road•P.O.Box 1179 Southold,NY 11971-0959 Eric Dantes Office Location: Gerard P.Goehringer • Y� Town Annex/First Floor,Capital One Bank Georgd Horning Q 54375 Main Road(at Youngs Avenue) Kenneth Schneider �yCOU NI`I,� Southold,NY 11971 RoDFSQE�VF3RONING ht ://southoldtown.northfork.net RECEIVE® BOARD OF APPEALS ?',al PM FEB 2 7 2017 TOWN OF SOUTHOLD FEB 2 2 2011 Tel.(631)765-1809•Fax(631)765-9064 BUILDING DEPT- So old Town lerk_. TOWN OF 5®FOLD INDINGS,DELIBERATIONS AND DETERMINATION MEETING OF FEBRUARY 16,2017 ZBA FILE: 7023 NAME OF APPLICANT:MGH Enterprises,Inc.Verizon Wireless PROPERTY LOCATION: 40200 NYS Route 25, Orient,NY SCTM#1000-15-9-8.1 SEORA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps under SEQRA. SUFFOLK COUNTY ADMINISTRATIVE CODE: This application was referred as required under the Suffolk County Administrative Code Sections A 14-14 to 23, and the Suffolk County Department of Planning issued its reply dated December 19, 2016 stating that this application is considered a matter for local determination as there appears to be no significant county-wide or inter-community impact. LWRP DETERMINATION: This application was referred for review under Chapter 268, Waterfront Consistency review of the Town of Southold Town Code and the Local Waterfront Revitalization Program (LWRP) Policy Standards.The LWRP Coordinator issued a recommendation dated January 30, 2017. Based upon the information provided on the LWRP Consistency Assessment Form submitted to-this department, as well as the records available, it is the coordinator's recommendation that the proposed action be EXEMPT from LWRP review pursuant to Chapter 268,Mainor Actions Item(F). TOWN OF SOUTHOLD PLANNING BOARD: This application was referred for comments to the Town of Southold Planning Board. In a memo dated January 27, 2017, Members of the Planning Board expressed their- support of the application with comments, and recommended that the Zoning Board of Appeals include a condition that the proposed location and height be confirmed by the Planning Board and their technical consultant as per Town Code. . PROPERTY FACTS/DESCRIPTION: Parcel is a conforming lot in the in the MII Zone. It is improved with a one story frame restaurant with attached deck, accessory one story and two story buildings,along with boat slips. It has 181.72 feet on Main Rd. (SR25)'to the north,752 feet along the easterly property line' 348.41 feet on Gardners-Bay to the south and 1000.1 feet on the westerly property line. Shown on a survey prepared by Hawkins Webb Jaeger, PLLC, last revised November 15, 2014 and a site plan (Page SP-10.0.00) prepared by WFC Architects, last revised May 23,2016. BASIS OF APPLICATION: Request for a Variance under Article XIII, Section 280-56; and the Building Inspector's October 18,2016 Notice of Disapproval based on an application for a permit to collocate a wireless Page 2,February 16,2017 #7023,MGH Enterprises,Verizon Wireless SCTrn No. 1000-15-9-8.1 communications facility on subject property at: 1) less than the code required minimum side yard setback of 25 feet; located,at: 40200 NYS Route 25,(Adj.to Gardeners Bay)Orient,NY. SCTM# 1000-15-9-8.1. RELIEF REQUESTED: The applicant requests variance relief to install a wireless telecommunications equipment compound with a side yard setback of 7.25 feet from the subject property line, adjacent to an R400 Zoned NYS State Park, where 25 feet is the minimum permitted by code. The Notice of Disapproval was amended on August 24,2016 to address the need for a variance from the Zoning Board of Appeals and further amended on October 18, 2016 to correct errors. ADDITIONAL INFORMATION: The Chief of Police of Southold Town submitted comments by email to the Chairperson of the Zoning Board of Appeals,on January 31,2017, addressing this application. He indicated that it was critically important that the proposed Verizon Wireless equipment be approved by the Board of Appeals. He stated that the local police participate in counter terrorism drills with other local, state and federal agencies; and that current spotty communications from Orient Point and Plum Island both by radio and cell phones would be greatly improved with the installation of this proposed cellular equipment. The Suffolk County Police Department indicated in their letter of December 2,2016 submitted by the applicant,that they fully support the application due to the need for communications coverage for police and public safety. The applicant also submitted several reports including three engineering reports and an FCC Compliance Assessment Report which will all be forwarded to the Planning Department for their review of the site plan application. On February 15,2012 in ZBA#6533,the Zoning Board granted MGH Enterprises Inc./New Cingular Wireless, LLC variance relief to install a new wireless communications tower and equipment compound having a 7.1 foot side yard setback from the property line,which was subject to a condition that they return to the Zoning Board if, in future,they wish to increase the height of the monopole. FINDINGS OF FACT/REASONS FOR BOARD ACTION: The Zoning Board of Appeals held a public hearing on this application on February 2,2017 at which time written and oral evidence were presented. Based upon all testimony, documentation,personal inspection of the property and surrounding neighborhood,and other evidence,the Zoning Board finds the following facts to be true and relevant and makes the following findings: 1. Town Law 5267-b(3)(b)(1). Grant of the variance will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties, The surrounding area is of mixed uses containing a marina, a restaurant, an office building and parking used by Plum Island employees, a large interstate ferry terminal with parking area, an R-400 zoned protected NYS State Park which cannot be subdivided and two large residential developments across NYS Route 25,to the north. Any detriment is mitigated by the placement of the proposed cellular equipment compound at the southernmost end of the property which is the farthest distance from existing buildings and residences in the area. Additionally dense screening exists on site and is proposed for the new equipment compound to further mitigate visual impacts. 2. Town Law 5267-b(3)(b)(2). The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance. To function properly, the proposed equipment compound must be located next to the existing equipment compound which was previously granted a 7 ft. 1 in. side yard setback 3. Town Law V67-b(3)(b)(3). The variance granted herein is mathematically substantial, representing 70% relief from the code.However,the proposed equipment will be concealed inside a secure fenced compound area screened from the adjoining State Park area with landscaping and adjacent to an existing equipment Page 3,February 16,2017 #7023,MGH Enterprises,Verizon Wireless SCTm No.1000-15-9-8.1 4. compound that has had no adverse impact. Moreover, the colocation on the existing monopole will improve cell coverage needed by the community and law enforcement agencies and the Town supports collocation of existing antennas,instead of creating new sites in many locations. . Town Law $267-b(3)(b)(4) No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. The applicant must comply with Chapter 236 of the Town's Storm Water Management Code. The adjacent residential property is owned by Long Island State Park Commission (Orient State Park) and has no residential structures located within the required fall zone and is the access roadway to the park with no access to the beach within the area of the monopole site. 5. Town Law &267-b(3)(b)(5). The difficulty has been self-created.However,the original site chosen for the existing tower has not caused any physical or environmental problems for either the surrounding residentiallcommunity or the commercial community. 6. Town Law X267-b. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of new wireless telecommunications equipment while preserving and protecting the character of the neighborhood and the health,safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-13, motion was offered by Member Weisman (Chairperson), seconded by Member Dantes,and duly carried,to GRANT the variance as applied for, and shown on the five page Site Plan(Pages T-100.00, SP-100.00,A-100.00, A-101.00,A-102.00,prepared by WFC Architects,last revised May 23,2016. SUBJECT TO THE FOLLOWING CONDITIONS: 1. Pursuant to the request by the Town of Southold Planning Board,proposed location and height of the telecommunications monopole must be confirmed by the Planning Board and their technical consultant as per Town Code. That the above conditions be written into the Building Inspector's Certificate of Occupancy, when issued. Any deviation from the survey, site plan and/or architectural drawings cited in this decision will result in delays and/or a possible denial by the Building Department of a building permit, and may require a new application and public hearing before the Zoning Board of Appeals. Any deviation from the variances)granted herein as shown on the architectural drawings, site plan and/or survey cited above, such as alterations, extensions, or demolitions, are not authorized under this application when involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of nonconformity. a Page 4,February 16,2017 #7023,MGH Enterprises,Verizon Wireless SCTm No. 1000-15-9-8.1 Pursuant to Chapter 280-146(B) of the Code of the Town of Southold any variance granted by the Board of Appeals shall become null and void where a Certificate of Occupancy has not been procured,and/or a subdivision map has not been filed with the Suffolk County Clerk,within three (3)years from the date such variance was granted. The Board of Appeals may, upon written request prior to the date of expiration, grant an extension not to exceed three (3) consecutive one (1)year terms. Vote of the Board: Ayes:Members Weisman (Chairperson), Schneider, Horning and Dantes. (Member Goehringer not present) This Resolution was duly adopted(4-0). Leslie Kanes Weisman,Chairperson Approved for filing / a� /2017 .� MAILING ADDRESS: pLANNnvDON�oJ.�lviElr>BERs � .. � pF SO P.O.ENSIGSouthold,NY . Chau OFFICE LOCATION: WILLIAM J.CREMERS v,. Town Hall Annex PIERCE RAFFERTY 54375 State Route 25 JAMES H.RICH III �l � (cor.Main Rd.&Youngs Ave.) MARTIN H.SIDOR �'®�Iq 1 + Southold,NY Telephone:631765-1938 www.southoldtownnygov PLANNING EOAPJD OFFICE TOWN OF SOUTHOLD April 11, 2017 Denise J. Vista, Esq, Amato Law Group, PLLC ; 666 Old Country Road, Suite 901 Garden City, NY 11530 Re: Approval: Proposed Co-location for Verizon Wireless at MGH Enterprises ' Located at 40200 Rt. 25, ±345'sfw/o Lands End Rd. & NYS Rt. 25, Orient. SCTM#1000-15-9-8.1 Zoning District: Mil Dear Ms. Vista: The following resolutions were adopted at a meeting of the Southold Town Planning Board on April 10, 2017: WHEREAS, this Amended Wireless Communications Application is for a proposed 20 ft. pole extension to an approved 70 ft. high concealment pole for a Verizon Wireless co- location of an interior mounted antenna between 70'and 90'above ground level, a 10 kw diesel generator with sound enclosure, associated ground equipment and additional landscaping. There are±3,924 sq.ft. of existing buildings including a restaurant, marina and associated accessory structures, all on 4.7 acres in the Marine II Zoning District; and WHEREAS, on May 23, 2016, pursuant to§280-74A(4) of the Town Code,the Planning Board entered into a Letter of Agreement with CityScape Consultants, Inc, to provide technical assistance to the Board in reviewing and evaluating the proposed wireless application; and WHEREAS, on June 2, 2016, Denise J. Vista, Esq., agent to the applicant, submitted an application for Site Plan and Special Exception review; and WHEREAS, on June 6, 2016, pursuant to §280-74A(4) of the Town Code,the Planning Board required the submission of$4,000 into an escrow account with the Town Comptroller's Office to cover the cost of the Technical Consultant's Review; and Verizon Wireless 0 MGH Enterorises Pae L2 April 11, 2017 WHEREAS, on June 21, 2016, Denise J.Vista, agent to the applicant, submitted a check in the amount of$4,000 to the Office of the Planning Board; and WHEREAS, on June 28, 2016, the Planning Board authorized CityScape Consultants to proceed with the work as outlined in the agreement; and WHEREAS, on July 11, 2016, the Planning Board found the application complete for review and to obtain a revised notice of disapproval for the expansion of the equipment compound at less than the required side yard setback; and WHEREAS, on July 21, 2016, the Planning Board, pursuant to Southold Town Code §280-131 C., distributed the application to the required agencies for their comments; and WHEREAS, on July 28, 2016, the Southold Town Trustees determined that the proposed equipment compound requires an Administrative Permit and the 20' pole extension does not require a permit; and WHEREAS, on August 26, 2016, the Orient Fire District determined there was adequate fire protection and emergency access for the site; and WHEREAS, on September 12, 2016, a public hearing was held and closed by the Planning Board for the above-referenced Site Plan; and WHEREAS, on September 16, 2016, the Southold Town Fire Inspector reviewed and determined that there was adequate fire protection and emergency access for the site; and WHEREAS, on September 22, 2016, the Architectural Review Committee(ARC) - reviewed the proposed project and approved the design as submitted; and WHEREAS, on September 27, 2016, the Southold Town Engineer reviewed the above- referenced application and determined the project meets the minimum requirements of Chapter 236 for Storm Water Management; and WHEREAS, on November 14, 2016, the NYS Department of Environmental Conservation (NYSDEC) issued a Tidal Wetlands Permit(1-4738-00898/00022)that expires August 25, 2021; and WHEREAS, on January 30, 2017, the Town of Southold LWRP Coordinator reviewed the above-referenced project and determined the proposed project is exempt from the Southold Town LWRP Chapter 268, Minor Actions item (F); and WHEREAS, on February 28, 2017, the Zoning Board of Appeals (ZBA) granted an area variance under file#7023 with one(1) condition, for the proposed equipment compound at less than the required side yard setback of 25' in the Marine—II (M-II)zoning district. Verizon Wireless 0 MGH Enterprises Pae 13 April 11. 2017 The proposed compound is provided at 73."Condition: Pursuant to the request by the Town of Southold Planning Board, proposed location and height of the telecommunications monopole must be confirmed by the Planning Board and their technical consultant as per Town Code; and WHEREAS, on March 29, 2017, the Southold Town Chief Building Inspector reviewed and certified the proposed Wireless Communication Facility as a permitted use in the M-, 11 Zoning District pursuant to ZBA file#7023; and WHEREAS, at a Work Session held on April 10, 2017, the Planning Board reviewed the reports issued by CityScape Consultants on July 18, 2016 and April 5, 2017, and determined that the action falls within the regulations of federal code Part 6409 of the Middle Class Tax and Job Creation Act of 2012. The increase to the height of the existing tower, because it is no more than 20 feet, and because there is no substantial change to its appearance (the new antennas will be concealed the same as the existing) must be approved under this federal regulation, and local zoning is essentially overridden. In this case, the Town's zoning pursuant to§280-701(2)for the maximum height of 80 feet, §280-701(3)for the minimum distance of all wireless equipment to adjacent residential property lines, and§280-70(G) Fall Zone,are all overridden. The ground compound, however, is not covered by the regulation, and local zoning is applicable. Therefore the proposal to locate the ground compound at a setback less than required by zoning required a thorough review by the Zoning Board of Appeals for a variance; and WHEREAS, the Planning Board recognizes that the reduction of the setback regulations is a local decision pursuant to ZBA file#7023, where it was found that the available space on the property is severely limited, the property owner accepts the changes, and the Applicant certifies and attests there is no alternative without the reduction of setback.The Board also found that the reduction of the setback is sufficiently unique in this M- 11 Zoning District and for this specific parcel based on its size, shape and existing development pattern. This, together with the addition of Verizon with this colocation proposal to provide improved personal wireless communications services to the public, provided the rationale for the Board to determine that it is reasonable in this situation to approve the expansion of the ground compound, thus reducing the setback regulations. Therefore, the technical consultant states that with the combination of federal and local codes as stated above, this application can be approved as proposed; and WHEREAS, at a Work Session held on April 10, 2017, the Planning Board found that all applicable requirements of the Site Plan Regulations Article XXIV, §280—Site Plan Approval of the Town of Southold have been met; be it therefore RESOLVED, that the Southold Town Planning Board has determined that this proposed action is exempt from the policies of the Town of Southold Local Waterfront Revitalization Program; and be it further Verizon Wireless Ccs MGH Enterprises Pae 14 April 11, 2017 RESOLVED, that the Southold Town Planning Board grants Approval with five (5) conditions to the Site Plan entitled"Verizon Wireless Communications at Orient Point prepared by Neil Alexander Macdonald, R.A, dated March 1, 2016 and last revised May 23, 2016, and authorizes the Chairman to endorse the Site Plan, including the following five plans: 1. T-100.00—Title Sheet 2. SP-100.00—Architectural Site Plan 3. A-100.00—East Elevation, Enlarged Equipment Plan 4. A-101.00—Antenna and Equipment Details and Antenna Plumbing Diagram 5. A-102.00—Light Specification Conditions: 1. Prior to a building permit being Issued,the applicant shall submit draft Covenants and Restrictions (C&R's)to the Planning Board for their review and approval. Once approved,the C&R's must be filed with the Office of the Suffolk County Clerk and a receipt of the filing provided to the Planning Board prior to the issuance of the building permit. The C&R's are for the purpose of ensuring the screening vegetation around the expanded ground equipment compound Is maintained as approved for the life of this facility; and 2. All of Applicant's feed lineskables shall be installed inside the monopole structure; and 3. All ports shall remain sufficiently sealed to prevent access by birds and other wildlife; and 4. The Applicant shall confirm the generator will comply with the Southold Ordinance noise guidelines; and 5. The facility shall remain secured and protected from unauthorized personnel. Please note the following requirements in the Southold Town Code relating to Site Plans: 1. No outdoor lighting was approved with this application.Any outdoor lighting at this wireless facility must be reviewed and approved by the Planning Board, and shall be shielded so the light source is not visible from adjacent properties and roadways. Lighting fixtures shall focus and direct the light in such a manner as to contain the light and glare within property boundaries. 2. All storm water run-off from grading, an and gravel areas must be contained on site. 1 Verizon Wireless Co-MGH Enten rises Pae 15 April 11. 2017 3. Approved Site Plans are valid for eighteen months from the date of approval, within which time all proposed work must be completed, unless the Planning Board grants an extension.' 4. Any changes from the Approved Site Plan shall require Planning Board approval. 5. Prior to the issuance of a Certificate of Occupancy, the Planning Board must inspect the site to ensure it is in conformity with the Approved Site Plan, and issue a final site inspection approval letter. Should the site be found not in conformance with the Approved Site Plan, no Certificate of Occupancy may be issued unless the Planning Board approves the changes to the plan. A copy of the Approved Site Plan is enclosed for your records. One copy will also be sent to the Building Department and the Town Engineer/Highway Department. If you have any questions regarding the above, please contact this office. Very truly yours, Donald J.Wilcenski Chairman Encl. cc: Michael Verity, Chief Building Inspector, with map James Richter, Engineering Inspector,with map By signing this letter, the applicant acknowledges that there are Town Code requirements and conditions, including those listed above,that must be satisfied prior to the issuance of a Building Permit. Print name: Michael Failla , ApplicantlAgent New York SMSA Limited Partnership d/b/a Verizon Wireless Signature: AU il,-o Date: 4-12,1117 Title: Senior Manager-construction i OFFICE LOCATION: MAILING ADDRESS: Town Hall Annex �fj �5 t} iT,t P.O.Box 1179 54375 State Route 25q`' 3=` Southold,NY 11971 (cor.Main Rd. &Youngs Ave.) v, ' Southold NY Telephone: 631765-1938 .; www.southoldtownny.gov PLANNING BOARD OFFICE TOWN OF SOUTHOLD FD) D March 14, 2018 1 n MAR 1 6 2018 John Coughlin, Esq. BUILDING DEPS'. c/o R6, Nielsen, Huber& Coughlin, LLP TOWN OF SOITHOLD 36 North New York Avenue Huntington, NY 11743 Re: Special Exception Renewal: New Cingular Wireless/MGH Enterprises Located at 40200 NYS Rt. 25, ±400' east of Cedar Beach Rd, Orient SCTM#1000-15-9-8.1 Zoning District: Marine-II Dear Mr. Coughlin: The Southold Town Planning Board adopted the following resolution at a Public Meeting held on Monday, March 12, 2018: WHEREAS, on September 17, 2012, the Southold Town Planning Board granted a Special Exception for the Wireless Communication Facility for New Cingular Wireless at the location referenced above; and WHEREAS, the approved facility consists of a 70' monopole having internally mounted antennas at 67' and 57' for New Cingular Wireless along with related 400 sq. ft. base equipment area; and WHEREAS, on September 12, 2017, the Special Exception Approval for the Wireless Communication Facility, pursuant to Town Code §280-73(D), expired; and WHEREAS, on February 27, 2018, John J. Coughlin, Esq., authorized agent, submitted a request to renew the Special Exception Approval, together with documentation to substantiate the application's eligibility for a renewal; and WHEREAS, at their Work Session on March 12, 2018, the Planning Board found: (1)the wireless communication facility is in compliance with all applicable laws, rules and regulations; (2) the site remains in compliance with all of the conditions of the special Southold Town Planning Board Page 2 March 14, 2018 exception approval and site plan; (3) the facility is necessary to provide adequate service; (4) that there is no reasonable alternative available to the owner which will provide adequate service without the continuing use of the facility; (5) the Town Code relating to Wireless Communication Facilities has not changed since this application was approve; therefore be it RESOLVED, that the Southold Town Planning Board hereby renews the Special Exception Approval for the Wireless Facility as shown in the site plan application for "New Cingular Wireless/MGH Enterprises", prepared by William F. Collins, dated April 1, 2009, and last revised August 11, 2012. Please also note the following requirements in the Southold Town Code relating to Special Exceptions: 1. Any Special Exception Approval granted under this article shall have a term of five years, commencing from the granting of the Special Exception, which may be extended for an additional five-year term upon application to the Planning Board. 2. On a renewal application, the applicant shall demonstrate that the wireless communication facility is in compliance with all applicable laws, rules and regulations and with all of the conditions of the Special Exception Approval and site plan, that the facility is necessary to provide adequate service, and that there is no reasonable alternative available to the owner which will provide adequate service without the continuing use of the facility. 3. Subsequent Special Exception renewals shall be subject to review by the Planning Board and subject to such standards that shall be included in the Town Code at that point in time. If you have any questions regarding the information contained in this resolution, please contact the Planning Board Office. Respectfully, Donald J. Wilcenski Chairman Encl. cc: Town Engineer Building Dept. OFFICE LOCATION: MAILING ADDRESS: Town Hall Annex ��oE S®UjjyO P.O. Box 1179 54375 State Route 25 h0 l0 Southold, NY 11971 (cor.Main Rd. &Youngs Ave.) Southold, NY Telephone: 631 765-1938 vs www.southoldtownny.gov �< COUNT`(, PLANNING BOARD OFFICE TOWN OF SOUTHOLD September 13, 2018 DD SEP 1 2 2018 Denise J. Vista, Esq. Amato Law Group, PLLC BUILDING DEPT. 666 Old Country Road, Suite 901 TOWN OF SOUT�OLD Garden City, NY 11530 Re: Approved Amended Site Plan for Verizon Wireless @ MGH 40200 NYS Rt. 25, Orient SCTM#1000-15-9-8.1 Zoning District: M-II Dear Ms. Vista: The Planning Board has found that the requirements of the above-referenced amended site plan have been completed based on the photos submitted August 24, 2018 and the site inspection made September 12, 2018. The site is now in conformance with the Approved Site Plan entitled "Verizon Wireless Communications at Orient Point", prepared by Neil Alexander Macdonald, R.A, dated March 1, 2016 and last revised May 23, 2016. This letter does not condone any changes from the approved Site Plan and from approvals permitted by other agencies; Planning Board approval is required prior to any significant changes to the site. Please, if you have any questions regarding this site plan or its process, do not hesitate to call this office at 631-765-1938. Respectfully, Donald J. Wilcenski Chairman cc: Michael Verity, Chief Building Inspector Jamie Richter, Town Engineering Inspector I I sovey0 < i Town Hall Annexa( Telephone(631)765.1802 , y 51375 Main Road cn (631176�9��2 I P.O.Box 1179 Q roger.richertCa NN.soulno .ny.us Southold,NY 11971-0959 U01 I BUILDING DEPARTi4 TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION ! F REQUESTED BY: Roly_,+ Kc.i, I n Date: Company Name: �+r GcNSn u(:hLn Clorp ' Name: .� License No.: Address: - �- r 4 I Phone No.: (DB _ -3(-05- . U JOBSITE INFORMATION: (*Indicates required information) *Name: e,r '2o ' 'Address: MQin. RVd )I 5 *Cross Street: `Phone No.: CQ 31 • e Permit No.: Tax-Map District: 1000 Section:_5. Block: qLot:—8—�— *13RIEF DESCRIPTION OF WORK(Please Print Clearly) Cc 1( s Q ro\!i & 20o Qrno . S'I h(Ile Oh2S . C ombi nia-hon Swt'kh (Please Circle All That Apply) r\O l n C krCW i breaVQ,( One l . Is job ready for inspection: YES /� Rough In Final *Do you need a Temp Certificate: YES NO Temp Information (if-needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connec Underground Number of Meters Change of Service Overhead n 4':F I a Additional Information: PAYMENT DUE WITH APPLICATION 1,,'-+,n �,Winne_ .k n Q a� .r i1 i �Q -�-o PSc= � -I�C�.r�S ►�m� oq cri�f 02-Request for InspeclJon Form � � T Y ta-A i off. y-�• _ -, _ 'B ldI - - - '` �• = , - _- -- LDIIVG=DEPARTPHENT =_ _' ,`> • .- 7ownHall'Annez Teleh one,6 65=1 P, 'Fax(631)i765 J502.;; =Date - -. dectificat" h� RAMM 3 y tiM. •; ase L��' - ^�','4Y,Y .YAP"¢'"`x N- ..1_ - :'C✓.> - re,F' 'l,"+.�• '"Si� j,1 yfS�M`/(Xz`� euv Seice, atia=ofSe .; 9_s , __ rv(ce,�;�'.ReconriectE�cistn"Servi i ' s• A� ;'i_ -'— firJY A [� ��zu}.• =`�=:�'��.ssifetlFto ��•z :-� �.�r f•, �3. Oc -� �� .r.�.�... G; - _ �. "_. :r; •, � 1 °lisfalled:b`�Y7 �pp AppGcation4or3electricai servire;equipment is;on°iiio-with'the'fown;dt Soutftoid:On applicant's otifcaton~FS' that this`instaliation'Is com tete, a town will conduct-a premise's irispection,of the service a ui merit, i This:veri c to sYalid,f q P `above;clate: Authorized by - i - D 16 V � OCT 4 2017 RVXDM ®LEP1®FSvi�® 1 AMATO LXW GROUP, PLLC COUNSELORS AT LAW 666 OLD COUNTRY ROAD 9TH FLOOR 405 LEXINGTON AVE GARDEN CITY,NEW YORK 11530 402 MAIN ST. CHRYSLER BLDG,26TH FLR -""""-" SUITE 204 NEW YORK,N.Y.10174 TEL:(516)227-6363 METUCHEN,NJ 08840 TEL:(212)485-6000 FAX:(516)227-6367 TEL:(732)317-1511 FAX:(212)485-6001 FAX:(732)317-1513 April 29, 2016 BY FEDERAL EXPRESS Building Department Town of Southold Town Hall Annex 54375 Main Road Southold,New York 11971 Re: Building Permit Application(the"Application")by New York SMSA Limited Partnership d/b/a Verizon Wireless("Verizon Wireless")to the Town of Southold in connection with the proposed public utility wireless communication facility(the"Communication Facility")to be collocated at 40200 Main Road,Orient,New York,known and designated as District 1000, Section 15,Block 9,Lot 8.1 (the"Property") NYSMSA Site Reference: Orient Point 2/Our File No. 100-0773 Dear Sir/Madam: In connection with Verizon Wireless' Application for the proposed Communication Facility to be located at the Property, enclosed are the following materials: 1. Two (2)Application for Building Permit forms; 2. Copies of the covenants and restrictions recorded on the Property; 3. Survey of the Property; 4. Authorization and Consent, executed by the Property owner; 5. Consent to Inspection form, executed by the Property owner; 6. Structural Analysis Report with Modification Design,prepared,signed and sealed,by GPD, dated February 26, 2016; 7. Four sets of construction drawings,prepared,signed and sealed by WFC Architects, LLP, issued for filing on April 22,2015; and 8. Application filing fee in the amount of$50.00. If everything is in proper order.please issue the Notice of Disapproval at your earliest convenience. If you should have any questions regarding the foregoing,please do not hesitate to contact me. Thank you for your attention to this Application. Very truly yours, L&JR(ZR0V[E Denise J. Vista DD MAY - 32016 Enclosures cc: Verizon Wireless (via email, without enclosures) BUILDING DEPT. TOWN OF SOUTHO LD AMATO LAW GROUP, PLLC COUNSELORS AT LAW ��Q \ /01 666 OLD COUNTRY ROAD \' V 9TH FLOOR 405 LEXINGTON AVE GARDEN CITY,NEW YORK 11530 402 MAIN ST. CHRYSLER BLDG,26TH FLR -- - SUITE 204 NEW YORK,N.Y.10174 TEL:(516)227-6363 METUCHEN,NJ 08840 TEL:(212)485-6000 FAX:(516)227-6367 TEL:(732)317-1511 FAX:(212)485-6001 FAX:(732)317-1513 October 19,2016 BY FEDERAL EXPRESS Mr. Damon Rallis Building Department Town of Southold Town Hall Annex Building 54375 Main Road Southold,New York 11971 Re: Building Permit Application (the "Application") by New York SMSA Limited Partnership d/b/a Verizon Wireless("Verizon Wireless")to the Town of Southold in connection with the proposed public utility wireless communication facility to be collocated at 40200 Main Road, Orient,New York, known and designated as District 1000, Section 15,Block 9,Lot 8.1 NYSMSA Site Reference: Orient Point 2/Our File No. 100-0773 Dear Mr. Rallis: In connection with the renewal of the Notice of Disapproval for Verizon Wireless' Application, enclosed is a check in the amount of$50.00. Kindly issue the original, renewed and amended Notice of Disapproval at your earliest convenience. If you should have any questions regarding the foregoing,please do not hesitate to contact me. Thank you for your assistance with this matter. Ve my yours, Denise J. Vista Enclosure cc: Verizon Wireless (via email, without enclosures) AMATO LAW GROUP, PLLC COUNSELORS AT LAW 666 OLD COUNTRY ROAD 9TH FLOOR 405 LEXINGTON AVE GARDEN CITY,NEW YORK 11530 402 MAIN ST. CHRYSLER BLDG,26TH FLR SUITE 204 NEW YORK,N.Y.10174 TEL.(516)227-6363 METUCHEN,NJ 08840 TEL:(212)485-6000 FAX-(516)227-6367 TEL:(732)317-1511 FAX:(212)485-6001 FAX:(732)317-1513 May 19, 2017 VIA HAND DELIVERY D BuildingDepartment p artment D Town of Southold MAY 19 2017 Town Hall Annex 54375 Main Road a'- BMI9ING P�'I'. Southold,New York 11971 T07N OF SOUi" 1UT-) Re: Building Permit Application (the "Application") by New York SMSA Limited Partnership d/b/a Verizon Wireless ("Verizon Wireless") to the Town of Southold (the"Town")in connection with the proposed public utility wireless communication facility(the"Communication Facility")to be collocated at 40200 Main Road,Orient, New York,known and designated as District 1000, Section 15,Block 9,Lot 8.1 (the "Property") NYSMSA Site Reference: Orient Point 2 /Our File No. 100-0773 Dear Sir/Madam: In connection with Verizon Wireless' Application for the proposed Communication Facility to be collocated on the Property, enclosed are the following supplemental materials: 1. Copy of the decision issued by the Town Zoning Board of Appeals on February 16, 2017, for File 7023; 2. Copy of the Site Plan Approval issued by the Town Planning Department on April 11, 2017; 3. Certified copy of the Declaration of Covenants and Restrictions recorded on the Property, together with a receipt of filing from the Suffolk County Clerk; 4. Two (2) Applications for Certificates of Occupancy; 5. Application for Electrical Inspection; 6. Certificates of Liability,Disability, and Worker's Compensation Insurance,naming the Town as Certificate Holder, from Telecom Engineering Group Inc., the project contractor; 7. Certificates of Liability,Disability,and Worker's Compensation Insurance,naming AMATO LAW GROUP, PLLC the Town as Certificate Holder,from B&D Electrical Construction Corp.,the project electrician; 8. Four (4) sets of construction drawings, prepared, signed and sealed by WFC Architects, issued for filing on February 21, 2017; and 9. Check,in the amount of$550.00,representing the Building Permit and Certificate of Occupancy fees. If everything is in order, kindly issue the building permit at your earliest convenience. If you should have any questions regarding the foregoing, please do not hesitate to contact me. Thank you for your attention to this Application. Very truly ours, Denise J. Vista Enclosures cc: Verizon Wireless (via email, without enclosures) oF so�jyQl 0 Town Hall Annex Telephone(631)765-1802 ,54375 Main Road cn Fax(631)765-9502 P.O.Box 1179 G • Q Southold,NY 11971-0959 'Q �y�OUNTf,�� April 2, 2018 BUILDING DEPARTMENT TOWN OF SOUTHOLD Amato Law Group Denise Vista 666 Old Country Rd, 9th Floor Garden City, NY 11539 Re: Verizon Wireless, 40200 Rte 25, Orient TO WHOM IT MAY CONCERN: The Fo owing Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: TE: Certification letter from Engineer for all work done under this building permit Electrical Underwriters Certificate A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 41667 —Wireless; - AMATO 666 OLD COUNTRY ROAD, 9TH FLOOR GARDEN CITY, NY 11530 LAW GROUP, P L L C TEL: 516.227.6363 1 FAX: 516.227.6367 September 14, 2018 o LE VIA FEDERAL EXPRESS L '~ ' Ms. Susan Pontino 4 )t Building Department SEP 1 7 2018 Town of Southold Town Hall Annex Building RIMBTNTG DEPT. 54375 Main Road .,Y Southold,New York 11971 Re: Building Permit No.41667(the"Building Permit")issued by the Town of Southold Building Department to New York SMSA Limited Partnership d/b/a Verizon Wireless("Verizon Wireless")in connection with the approved public utility wireless communication facility located at 40200 Main Road,Orient,New York,known and designated as District 1000, Section 15, Block 9, Lot 8.1 (the "Property") NYSMSA Site Reference: Orient Point 2/Our File No. 100-0773 Dear Ms. Pontino: As discussed,enclosed please find the final Engineer Certification letter,signed and sealed by Neil A. MacDonald,AIA,LEED AP, on behalf of WFC Architects, for purposes of closing out the Building Permit at the above referenced Property. If everything is in order, please issue the Certificate of Occupancy/Completion at your earliest convenience. Thank you for your attention to this matter. V truly yours, nise J. Vista Enclosures cc: Verizon Wireless (via email w/o enclosures) 405 LEXINGTON AVENUE I CHRYSLER BUILDING,26TH FLOOR I NEW YORK,NY 10174 1 212.485 6000 402 MAIN STREET I SUITE 204 1 METUCHEN,NJ 08840 1 732.317.1511 TELCO-1 OP ID: NK ACORO" DATE(MM/DD/YYYY) CERTIFICATE OF LIABILITY INSURANCE F02/10/2017 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT James J.Halstead III Scirocco Financial Group, Inc.309 PHONE 201-727-0070 FVC No•201-727-0080 777 Terrace Avenue,Suite 309 c o Hasbrouck Heights, NJ 07604 ADORLEss:jhalstead scirocco rou .com Scirocco Financial Group,Inc. INSURERS AFFORDING COVERAGE NAIC# INSURERA:Travelers Indemnity Company 25666 INSURED Telcom Engineering Group Inc. INSURER B:Continental Indemnity Co. 28258 Attn: Joe Roscitt INSURERC.RSUI Indemnity Company 22314 120 Commerce Road Carlstadt,NJ 07072 INSURERD:Houston Casualty Company 42374 INSURER E:Illinois Insurance Company 27960 INSURER F•Hanover Insurance Company 22292 COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDLSUBR POLICYNUMBER MPOLDDIYYY MMIDDPOLICYEXP LIMITS LTR A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,00 CLAIMS-MADE a OCCUR X DT-CO-7E72936A-TIA-16 06/30/2016 06/30/2017 PREMISES EaccTED currence $ 1,000,00 -T Contractual Liab MED EXP(Any one person) $ 10,000 Included PERSONAL&ADV INJURY $ 2,000,00 M'OTHER LAGGREGATELIMITAPPLIESPER GENERAL AGGREGATE $ 4,000,00 POLICY�JECT 7 LOC PRODUCTS-COMP/OPAGG $ 4,000,00$ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000000 Ea accident + A X ANY AUTO DT-81 0-7E72936A-TCT-1 6 06/30/2016 06/30/2017 BODILY INJURY(Per person) $ ALLOWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS NON OWNED PROPERTY DAMAGE $ HIRED AUTOS AUTOS Per accident F $ UMBRELLA LIAB XJ OCCUR EACH OCCURRENCE $ 5,000,00 A X EXCESS LIAB CLAIMS-MADE DTSM-CUP-7E72936A-TIL-16 06/30/2016 06/30/2017 AGGREGATE $ 5000,00 DED I X I RETENTION$ 10,000 $ WORKERS COMPENSATION X AND EMPLOYERS'LIABILITY STATUTE ER B ANY PROPRIETOR/PARTNER/EXECUTIVE 46-853742-01-08 06/18/2016 06/18/2017 E L EACH ACCIDENT $ 1,000,00 YIN N OFFICER/MEMBER EXCLUDED? N/A ) E (Mandatory In NH) 46-853742-01-09 ONLY) 06/18/2016 06/18/2017 E L DISEASE-EA EMPLOYE $ 1,000,00 ( If yes,describe under DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ 1,000,00 C Excess Liab. NHA076153 06/30/2016 06/30/2017 Oxcc/Agg 5,000,00 F Installation Fltr RHYA966732 06/30/2016 06/30/2017 Install. 1,000,00 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,maybe attached if more space Is required) Town of Southold is named as additional insured ATIMA as respects work performed by the named insured as required by written contract and to the extent provided by the actual policy language of the Commercial General Liability policy. CERTIFICATE HOLDER CANCELLATION TWNSOUT SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 53094 Route 25 Southold,NY 11971 AUTHORIZED REPRESENTATIVE G% k�C'u ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD YORK Workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board UNDER THE NYS DISABILITY BENEFITS LAW PART 1. To be completed by Disability Benefits Carrier or Licensed Insurance Agent of that Carrier 1 a. Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Telcom Engineering Group Inc. 201-969-8812 120 Commerce Road 1c NYS Unemployment Insurance Employer Registration Number of Carlstadt, NJ 07072 Insured Work Location of Insured(Only required If coverage is specifically limited to 1 d Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i e., a Wrap-Up Policy) Number 65-0283400 2 Name and Address of Entity Requesting Proof of Coverage 3a Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) AmGUARD Insurance Company Town of Southold 3b Policy Number of Entity Listed in Box"I a" 53094 Route 25 DBO1048180 Southold, NY 11971 3c.Policy effective period 01/01/2017 to 01/01/2018 4.Policy covers* X❑ A.All of the employer's employees eligible under the New York Disability Benefits Law ❑ B.Only the following class or classes of employer's employees; Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability Benefits insurance coverage as described above Date Signed 02/10/2017 By (Signature of insurance camer's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 800-673-2465 Title Vice President of Sales IMPORTANT' If Box"4a"is checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate Is COMPLETE Mail it directly to the certificate holder. If Box"4b"is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the Disability Benefits Law.It must be mailed for completion to the Workers'Compensation Board, DB Plans Acceptance Unit,328 State Street,Schenectady, NY 12305 PART 2. To be completed by the NYS Workers' Compensation Board (Only if Box"41b"of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability Benefits Law with respect to all of his/her employees. Date Signed By Signature of NYS Workers'Compensation Board Employee) _ Telephone Number Title Please Note: Only insurance carriers licensed to write NYS disability benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authonzed to issue Form DB-120 1 Insurance brokers are NOT authorized to issue this form. DB-120.1 (9-15) s New York State Insurance Fund Workers'Compensation&Disability Benefits Specialists Since 1914 8 CORPORATE CENTER DR,3RD FLR,MELVILLE,NEW YORK 11747-3129 CERTIFICATE OF WORKERS' COMPENSATION INSURANCE ns A A A A A A 200806542 B&G GROUP INC 55 W AMES CT STE 400 PLAINVIEW NY 11803 Scan to Validate POLICYHOLDER CERTIFICATE HOLDER B&D ELECTRICAL CONSTRUCTION CORP TOWN OF SOUTHOLD 200-18 E 2ND ST 53094 ROUTE 25 HUNTINGTON STATION NY 11746 SOUTHOLD NY 11974 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 11382791-0 475179 03/30/2017 TO 03/30/2018 5/17/2017 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 1382 791-0, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS.//WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER CLAIMS OR SUITS THAT ARISE FROM BODILY INJURY SUFFERED BY THE OFFICERS OF THE INSURED CORPORATION. ROBERT KALIN PRESIDENT AND DONALD HARDINA VICE PRES OF B&D ELECTRICAL CONSTRUCTION CORP A TWO PERSON CORPORATION THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER.260522617 U-26.3 CC# : C17-21077 � r COUNTY CLERK'S OFFICE STATE OF NEW YORK COUNTY OF SUFFOLK I, JUDITH A. PASCALE, Clerk of the County of Suffolk and the Court of Record thereof do hereby certify that I have compared the annexed with the original DECLARATION recorded in my office on 05/19/2017 under Liber D00012913 and Page 217 and, that the same is a true copy thereof, and of the whole of such original. In Testimony Whereof, I have hereunto set my hand and affixed the seal of said County and Court this 05/19/2017 SUFFOLK COUNTY CLERK C;?- a. JUDITH A.PASCALE SEAL I IIIIIII IIII VIII VIII VIII VIII VIII VIII VIII IIII IIII IIIIIII(IIII VIII IIII IIII SUFFOLK COUNTY CLERK RECORDS OFFICE RECORDING PAGE Type of Instrument: DECLARATION Recorded: 05/19/2017 Number of Pages : 8 At: 11 : 15 : 42 AM Receipt Number : 17-0085137 LIBER: D00012913 PAGE : 217 District: Section: Block: Lot: 1000 015 . 00 09. 00 008 . 001 EXAMINED AND CHARGED AS FOLLOWS Received the Following Fees For Above Instrument Exempt Exempt Page/Filing $40 . 00 NO Handling $20 . 00 NO COE $5 . 00 NO NYS SRCHG $15 . 00 NO TP-584 $0 . 00 NO Notation $0 . 00 NO Cert.Copies $40 . 00 NO RPT $200 . 00 NO Fees Paid $320 . 00 THIS PAGE IS A PART OF THE INSTRUMENT THIS IS NOT A BILL JUDITH A. PASCALE County Clerk, Suffolk County UIM % (rNumber of pages RE("'OR QED JUDITH Fir PASCALE OF This document will be public ,��F,=CLERK COUt;T4` record. Please remove all Social Security Numbers P 21 prior to recording. Deed/Mortgage Instrument Deed/Mortgage Tax Stamp Recording/Filing Stamps 3 FEES Page/Filing Fee Mortgage Amt. 1. Basic Tax Handling 20. 00 2. Additional Tax TP-584 Sub Total Notation Spec./Assit. or EA-52 17 (County) Sub Total Spec./Add. EA-5217 (State) TOT.MTG.TAX R.P.T.S.A. �� Dual Town Dual County � Held for Appointment Comm.of Ed. 5. 00 % Transfer Tax Affidavit Mansion Tax ����`' 0 The property covered by this mortgage is ified Copy or will be improved by a one or two ty! S Surcharge 15. 00family dwelling only. Sub Total YES or NO Other Grand Total If NO,see appropriate tax clause on page# of this instrument. 4 TDist. 3399933 1000 01500 0900 008001 5 Community Preservation Fund Real Propert R LWI I(IIIII IIIII IIIII IIIII IIIII IIIII VIII IIII IIII Consideration Amount $ Tax Service Agency 19-MAY-17 CPF Tax Due $ Verificatior, Improved 6 Satisfactions/Discharges/Releases List Property Owners Mailing Address RECORD &RETURN TO: ,Vacant Land Anw•cevo La,.0 Cy-oop Ri r_ TD • ccfG Old erxtc+,S'ly. 0) V TD TD Mail to: Judith A. Pascale, Suffolk County Clerk 7 Title Compawy Information 310 Center Drive, Riverhead, NY 11901 Co. Name www.suffolkcountyny.gov/clerk Title# 8 Suffolk County Recording & Endorsement Page This page forms part of the attached b-e C t— - made by: (SPECIFY TYPE OF INSTRUMENT) RVC ��. ��P f t S�S (J C The premises herein is situated in SUFFOLK COUNTY,NEW YORK. TO In the TOWN of In the VILLAGE or HAMLET of Q�' BOXES 6 THRU 8 MUST BE TYPED OR PRINTED IN BLACK INK ONLY PRIOR TO RECORDING OR FILING. 12-0104.10/O8kk over DECLARATION_OF,COVENANTS AND RESTRICTIONS THIS DECLARATION, made this If day of May, 2017, by M.G.H. Enterprises, Inc., with its principal offices located at 40200 Main Road (a/k/a New York State Route 25), Orient, New York 11957, hereinafter referred to as "DECLARANT": WITNESSETH : WHEREAS, the DECLARANT is the owner of certain real property located at 40200 Main Road (a/k/a New York State Route 25), Orient,New York 11957, County of Suffolk, State of New York, known and designated on the Suffolk County Tax Map as District 1000, Section 15, Block 9, Lot 8.1 (hereinafter referred to as the "Property"), which is more particularly bounded and described as set forth in"Schedule A" annexed hereto; and WHEREAS, the DECLARANT has entered into a lease agreement with New York SMSA Limited Partnership d/b/a Verizon Wireless ("Verizon Wireless") for Verizon Wireless to construct a wireless telecommunication facility (the "Communication Facility") on a portion of the Property, as depicted in"Schedule B" annexed hereto; and WHEREAS, Verizon Wireless has made an application to the Planning Board of the Town of Southold for Site Plan Approval to construct the Communication Facility on the Property, as shown on the site plan entitled "Orient Point 2," prepared by WFC Architects, issued for filing on May 23, 2016 (hereinafter referred to as the "Site Plan"); and WHEREAS, in a decision dated April 11, 2017, the Planning Board of the Town of Southold granted Verizon Wireless' Site Plan Application with conditions; WHEREAS, for and in consideration of the granting of Site Plan Approval, the Planning Board has deemed it in the best interests of the Town of Southold and the Property that the within covenants and restrictions be imposed on the Property, and as a condition of said approval, the Planning Board has required that this Declaration be filed in the Suffolk County Clerk's Office; and WHEREAS, the DECLARANT has considered the foregoing and has determined that same will be for the best interests of the DECLARANT and subsequent owners,and lessees of the Property. I J ! I I NOW, THEREFORE, THIS DECLARATION WITNESSETH: That the DECLARANT, for the purpose of carrying out the intentions above expressed, does hereby make known, admit, publish, covenant, and agree that the said Property herein described shall hereafter be subject to the covenants and restrictions as herein cited, which shall run with the land and shall be binding upon all purchasers, tenants, lessees, and/or holders of the Property, their heirs, executors, legal representatives, distributees, successors, and assigns, to wit: 1. The following landscaping will be planted on the Property in connection with Verizon Wireless' Communication Facility, as depicted on the approved Site Plan: a. Five (5) Eastern Red Cedar Trees will be planted along the west side of Verizon Wireless' proposed equipment area, which measures approximately 32' in length; b. Four (4) Eastern Red Cedar Trees will be planted along the north side of Verizon Wireless' proposed equipment area, which measures approximately 13'-10" in length; and c. The Eastern Red Cedars Trees shall provide contiguous screening of Verizon Wireless' equipment area to the north and west, and will be planted so that the branches are touching. 2. Additional Eastern Red Cedar Trees may be added to accomplish the purpose of the screening which is to mitigate any visual impacts to the adjacent New York State Park and the New York State Scenic Byway. 3. The landscaping shall be kept in good/healthy condition and shall be replaced should any tree(s) die at any point during the existence of Verizon Wireless' Communication Facility on the Property. The covenants and restrictions contained herein shall be construed to be in addition to, and not in derogation or limitation upon, any local, state, or federal laws, ordinances, regulations, or provisions in effect at the time of execution of this Declaration, or at the time such laws, ordinances, regulations and/or provisions may hereafter be revised, amended, or promulgated. If any section, subsection, paragraph, clause, phrase or provision of these covenants and restrictions shall, by a Court of competent jurisdiction, be adjudged illegal, unlawful, invalid or held to be unconstitutional, the same shall not affect the validity of these covenants as a whole, 2 or any other part or provision hereof other than the part so adjudged to be illegal, unlawful, invalid, or unconstitutional. The covenants and restrictions contained herein are intended for the benefit of and shall be enforceable by the Town of Southold, by injunctive relief or by any other remedy in equity or at law. The failure of the Town of Southold or any of its agencies to enforce same shall not be deemed to affect the validity of this Declaration nor to impose any liability whatsoever upon the Town of Southold or any office or employee thereof. The within covenants and restrictions shall run with the land and shall be binding upon the DECLARANT and its successors and assigns, and upon all persons or entities claiming under them, and may not be annulled, waived, changed, modified, terminated, revoked, or amended by subsequent owners of the premises unless and until approved by a majority plus one vote of the Planning Board of the Town of Southold or its successor, following a public hearing. Notwithstanding the foregoing, the within covenants and restrictions shall automatically terminate upon the removal or decommissioning of Verizon Wireless' Communication Facility. [SIGNATURE ON FOLLOWING PAGE] 3 i IN WITNESS WHEREOF, the DECLARANT has duly executed this Declaration on the day and year first above written. M.G.H. Enterprises, Inc. —-a16VA-46 By: Robert Haase, President STATE OF NEW YORK ss: COUNTY OF SUFFOLK On the jl;�day of - , 2017, before me the undersigned, personally appeared, Robert Haase, personally knownho me or proved to me on the basis of satisfactory evidence to be the individual whose name is subscribed to the within instrument and acknowledged to me that he executed the same in his capacity, and that by his signature on the instrument, the individual or the person on behalf of which the individual acted, executed the instrument. SWARD FEE" pubk.Sdb of New York No.61 I"sl•Suft Cojtj Tenn EO@s So;*8,oo3_ Notary Public 4 r SCHEDULE A PARCEL I: ALL THAT CERTAIN PLOT, PIECE OR PARCEL OF LAND, SITUATE, LYING AND BEING IN THE TOWN OF SOUTHOLD, COUNTY OF SUFFOLK AND STATE OF NEW YORK, BOUNDED AND DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE SOUTHERLY SIDE OF MAIN ROAD WHICH POINT MARKS THE NORTHWESTERLY CORNER OF PREMISES HEREIN DESCRIBED AND THE NORTHEASTERLY CORNER OF LAND FORMERLY OF THE STATE OF NEW YORK; RUNNING THENCE ALONG THE SOUTHERLY SIDE OF MAIN ROAD,NORTH 87° 09' 20" EAST, 151.72 FEET TO LAND OF THE UNITED STATES GOVERNMENT; THENCE BY LAST MENTIONED LAND, SOUTH 11° 43' 20" EAST, 752 FEET TO THE ORDINARY HIGH WATER MARK OF GARDINER'S BAY; THENCE SOUTHWESTERLY ALONG THE ORDINARY HIGH WATER MARK OF GARDINER'S BAY, THE TIE LINE OF WHICH BEARS SOUTH 39° 44' 40" WEST, 348.41 FEET TO LAND FORMERLY OF THE STATE OF NEW YORK; THENCE BY LAST MENTIONED LAND NORTH 40 40' 45" WEST, 1000 FEET TO THE SOUTHERLY SIDE OF MAIN ROAD, AT THE POINT OR PLACE OF BEGINNING. PARCEL II: ALL THAT CERTAIN PLOT, PIECE OR PARCEL OF LAND, SITUATE, LYING AND BEING IN THE TOWN OF SOUTHOLD, COUNTY OF SUFFOLK AND STATE OF NEW YORK, BOUNDED AND DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE SOUTHERLY SIDE OF MAIN ROAD, SAID POINT BEING WHERE THE NORTHEASTERLY CORNER OF THE PREMISES TO BE DESCRIBED AND THE NORTHWESTERLY CORNER OF LAND N/F OF M.G.H. ENTERPRISES, INC., AS DESCRIBED IN LIBER 8607 AT PAGE 67 INTERSECT SAID SOUTHERLY SIDE OF MAIN ROAD; RUNNING THENCE SOUTH 40 40' 45" EAST, ALONG THE LAND N/F OF M.G.H. ENTERPRISES, INC., 800.00 FEET; THENCE SOUTH 870 09' 20" WEST, 30.00 FEET, TO LAND OF ORIENT BEACH STATE PARK; THENCE NORTH 40 40' 45" WEST, ALONG THE LAND OF ORIENT BEACH STATE PARK, 800.00 FEET TO THE SOUTHERLY SIDE OF MAIN ROAD; THENCE NORTH 870 09' 20" EAST, ALONG THE SOUTHERLY SIDE OF MAIN ROAD, 30.00 FEET, TO POINT OR PLACE OF BEGINNING. 5 SCHEDULE B 6 i i i I f i i i °OR wt A ON OF R ro RESrDR AR]ED-mW R ARW ES�ME S5i. D To PE 1 1 1AW1nOx OF ax]nEYs ax0/OR EdIPURlf wITWx nOs SCOPE Oc `I /1 Lti 616-I06R) J 1 ; 1 ; •f� J I B£iD BE SR E SrtE SPEPnC-D.MOR BRE pu Oc ORunACC LLQ cnAB�C(wPM vERaOx HRELE55 NtwEtt 1CawC4 SPECF)GnOxs F01S EIIE SCxME ` d w SWPC 1 PROVED (5 �) L (SEE BECTON) L s R,cxEs ro¢_.auwlW.b Bulmum m_NE MALrfO ro �n w ---UxDEROROUxD wUnES N _BRE_.E0_Nl_ '•"' w L-,K,l S `\ OOurts WATEa1CNT TEST MON TO BMK`t NG ,i�C- e ENCE m BE AxgED SVMW N C-C. LUST t`' IONAIA ppvE w OP•uD,RD SEEIE)x BURDwO HRE OR • DE[6RDwfax Ax0 PUCEUUVr Oc ilE rbUw Nal x01 HdN DR­E E 3 iHxE THD) E"STARES wMTEAs[A[IraN P..S•FER WuuO—N,Aw TRE IRUAL Ax0 "�ON-SLOK_ u1-N OR 5E(NCES OR YHR E E.- x�ROSnwIHCONRUCBECtUROSDc�ROP �COT6DUClOx ro BE C1E•Rm PROR TO STMT or PEROSnNG _iSSWNDwus u LE«c+c oTxwoRTx u,o w¢i E[ixi umuwr ''E C: H I T r CGIUBExeARG6'PExE1M1bN MrowALE ErwMEL Liv �� �^ ] IMOS[•vwO 10 BE REPT M CWO/HERD CONwiON WD SNALL BEw,NO(sR SWnOx) pCye'])pN ACRD BMRM 9 / \ or T�EiE D BBxG a TREE(5) M AT-Pow.DUR.1 THE wRAnON ae�AOVE AW�UEuuGTu•OREED LB' 1F 5 um04 qua rtx ME.TO MOr 1�ERENCNE SILT FENCE DETAIL 4 HAY BALE DETAIL a 777 CONSTRUCTION DOCUMENTS FOR WIRELESS COMMUNICATIONS FACILITY. .41 17 { El v"pw" 0 R NT POINT 2 d, i i I F] 40200 MAIN ROAD ., ORIENT, NY 11957 We, . A R C H I T E C T S WFCPROJECT NO : 1 12-1 TECHNOLOGY DRIVE, SETAUKET, NY 11733 P. 631,689.8450 1 F. 631.689.8459 1 wu,%v.wfcaia.com SITE IN PROJECT CONTACTS DRAWING I INITIAL ISSUANCE RELATEST ISSUANCE VISION NO. 8. DATE VERIZON WIRELESS SITE NAME: "ORIENT POINT T APPLICANT: NEW YORK SMSA LIMITED PARTNERSHIP (914) 714-7371 DWG. NO. DRAWING TITLE d/b/a VERIZON WIRELESS 4 CENTEROCK ROAD ARCHITECTURAL I'I WEST NYACK, NY 10994 SITE TYPE/DESCRIPTION: WITHIN NEW 20' CONCEALMENT POLE EXTENSION: INSTALL T-100.00 TITLE SHEET 7/20/16 2 2/21/17 (3) NEW ANTENNAS AND (6) DIPLEXERS. PROPERTY OWNER: M.G.H. ENTERPRISES,INC. (631) 323-2424 G-100.00 GENERAL NOTES7/20/16 2 2/21/17 r- 40200 MAIN ROAD, ORIENT, NY 11957 ,;T, `• - AT GRADE: INSTALL NEW EQUIPMENT CABINETS, (3) NEW ROBERT HAASE SP-100.00 ARCHITECTURAL SITE PLAN 7/20/16 2 2/21/17 MAIN DISTRIBUTION BOXES, (12) NEW RRHs, (4) NEW GPS A-100.00 EAST ELEVATION, ENLARGED EQUIPMENT PLAN AND FENCING DETAILS 7/20/16 2 2/21/17 CONSULTANT: NEW E NEW (1) NEWSTEEIDU WAGE PLATFORMRATONEW CHAINATOP LEASING CONTACT: RYAN MAYBECK (914) 714-7371 A-101.00 STRUCTURAL DETAILS, FOUNDATION PLAN AND FRAMING PLAN 7/20/16 2 2/21/17 LINK FENCE WITH ENCLOSURE AND NEW SHRUBBERY. AA 02.00 CANOPY FRAMING PLAN AND CANOPY DETAILS 7/20/16 2 2/21/17 AA 03.00 ANTENNA INFORMATION AND EQUIPMENT DETAILS 7/20/16 2 2/21/17 MAY 1 9 2017 PROJECT LOCATION: 40200 MAIN ROAD CONSTRUCTION CONTACT: KENNY UHLL (631) 236-2108 A-1104.00 DETAILS 7/20/16 2 2/21/17 DU ORIENT, NY 11957 �LDIPdG I?1✓P'P. ELECTRICAL TOWN Or SOLTMOLD TAX MAP INFO:: SECTION 15, BLOCK 9 AND LOT 8.1 E-1100.00 RISER DIAGRAM, GENERATOR INFORMATION AND TRENCHING DETAILS 7/20/16 2 2/21/17 ZONING DISTRICT: 11000 A/E (ENGINEER) CONTACT: NEIL A.MacDONALD,AIA, LEED AP (631) 689-8450 EXT.115 E-101.00 GROUNDING INFORMATION 7/20/16 2 2/21/17 ZONING DESIGNATION: MARINE II NO. DATE SUBMISSION LATITUDE: 41.15294 (NAD 83) PSEG LONG ISLAND CONTACT: SUSAN BRUCE-FEINSOD (631) 348-6044 0 7/20/16 ISSUED FOR REVIEW 1 8/3/16 REVISED PER ATTORNEY COMMENTS LONGITUDE: -72.24419 (NAD 83) /21/17 ISSUED FOR FILING ELEVATION: 5' +1-AMSL (NGVD 29) ZONING JURISDICTION TOWN OF SOUTHOLD VZW PROJECT CODE: 2-0141122470 VZW LOCATION CODE: 311204 * CONTRACTOR SHALL COMPLY WITH THE NEW YORK ONE-CALL PROCEDURES BEFORE ANY EXCAVATION, DRILLING OR BORING. 1) ALL CONTRACTORS MUST CALL 2 TO 10 WORKING DAYS PRIOR TO START OF VZW CELL#: PROJECT AND RECORD THE SERIAL NUMBER AND LIST OF NOTIFIED UTILITY NO. DATE REVISION OPERATORS. , KEY PLAN: 2) AFTER CALLING THE CALLERS MUST WAIT THE 3 WORKING DAYS AS DESCRIBED IN NYS CODE 753 AS _ AREA OF WORK TO GIVE ADEQUATE TIME TO THE NOTIFIED OPERATORS TO RESPOND. rEonn enicn na"o t>Mrm.ea, 3) ALL CONTRACTORS MUST PROVIDE AS MUCH INFORMATION ON THE WORKSITE AS POSSIBLE TO THE ONE CALL CENTER. — — — -- - -' m eTM.°.rt7*3la�J^i a f°n eRp"...p•D • G f nm invr s.msr"rr scion 4) IT IS SUGGESTED WHEN WORKING ON AIRPORT PROPERTY THAT THE CALLER REQUEST A SITE MEETING `� AS TO MAKE THE WORK LOCATION CLEAR TO ALL MARK-OUT CREWS. D;",'''" `Z� ' ;` _�!r � E — 5) IF THE PROJECT IS TO EXTEND PAST 10 WORKING DAYS IT IS HIGHLY RECOMMENDED THAT THE TICKETS BE UPDATED EVERY 10 WORKING DAYS IN ORDER TO MAINTAIN MAXIMUM PROTECTION OF THE E . '`' "` i::_i'i'1n'I ta' PJT f T UNDERGROUND UTILITIES. FOR THE REQUIRED nRvnrrrn vrare _vesnrirvr CONCRETE 2. ATI I� MAP KEY AP 3. If' i:C) LO� ® 4. F {l):�1 i 0N !LUST y ?� C;t;'''^. i- iF. FO!, C.J. 7� / ALL TION S1 V1L MEET THE plum island � ?E )'',I!�?;�l:R�'i'1 I S Or �1�HE CODL::S OF NEW ;r anrral�A�e,:se+:ercer... YOB°t ;ii I E. NOT RESPONSlrLILE FOR Dc,;,,NI OR COt!'�T EiUCTlON ERRORS. 77- L+e w c, Anim, 6';( ca i 3,4-Cen c))n 1•,in.fn,nn -13 40200 Main Rd ° fir 4 "ORIENT POINT 2" w`� r e` 0200 Main Rd s^r r, r"aa Pi zr Time 34 ishlrig f 0 .'tel y'• 4!�s,jY , CE RTIC i E ` ,�, k 40200 MAIN ROAD pC!U NJ ' s ORIENT, NY 11957 TITLE: ���' fir; 9�.., ., . . . . .°, .• . ,� :: '`,`i TITLE SHEET DATE: JULY 13, 2016 PROJECT NO: 14-10823 F.ETAI'i�` STCn��4 Vt�AIER R'JN�FF DRAWN BY: MM PURSUAfj �d CHAPTER 236 CHECKED BY: TM OF TE`4E TOWN CODE' SCALE: AS NOTED SITE LOCATION NORTH � SITE LOCATION SCALE: 1 = 200' NORTH DRAWING NO: SHEET NO: 1 OF 10 GENERAL NOTES FOR CONSTRUCTION SYMBOL LEGEND ABBREVIATIONS GENERAL REQUIREMENTS DRAWING LEGEND: WARRANTIES: SITE LEGEND: A 1. Information shown on these drawings is for design intent only. Verify existingconditions A/C AIR CONDITIONING IG ISOLATED GROUND � 1. The Contractor shall guarantee all labor and materials used in this project for a minimum / and dimensions in field. Coordinate discrepancies with the architect and/or engineer. Do not 9 p 1 - New Wall Partition 24 Contour / Topo AC ACOUSTICAL ID INSIDE DIAMETER scale drawings to determine dimensions. period of one (1) year commencing from the date of final acceptance by the client. Line ACP ACOUSTICAL PANEL INFO INFORMATION 6 ; 2. Establish lines grades and benchmarks necessary for proper work from given survey ACT ACOUSTICAL TILE INSUL INSULATION (D) (ION) New Rated -- Property Line ADJ ADJACENT ISP INTEGRATED SERVICE PANEL . ' g ry 2. The Final date of acceptance is deemed as the date that all required state and federal Partition AFF ABOVE FINISH FLOOR data. work shall be erected and installed plumb, level, square and true and in proper approvals have been obtained including, but not limited to: AFG ABOVE FINISHED GRADE r alignment. A. Final inspection New Partial Ht. Stockade Fence AGL ABOVE GROUND LEVEL JC JANITOR'S CLOSET € p Partition Line 3. All work shall be done in strict accordance with provisions of local, state, federal, laws, B. Certificate of Occupancy ALT ALTERNATE ordinances, OSHA standards and regulations wherever applicable. Contractor shall Ex i s ting Partition -x-x-x- Chain Link Fence ATS AUTOMATIC TRANSFER SWITCH K Line ALUM ALUMINUM Kw KILOWATT coordinate and arrange all third part special fins ections required under NYSBC chapter 17. ; 3. Any deficiencies that come evident during this one (1) year period shall be corrected by ANSI AMERICAN NATIONAL STANDARDS INSTITUTE the Contractor at the Existing Door to oS Gas Piping Line L e Contractor's ex 4. The Contractor shall be responsible for quantities of work. furnish labor, materials and expense. Remain ANT ANTENNA LAM LAMINATE (D) equipment required to complete work. ` Dooir/Wall To E Electrical Conduit APPV'D APPROVED LAN LOCAL AREA NETWORK A R C H I T E C T S 5. Provide proof of workman's compensation insurance and disability insurance coverage QUALITY ASSURANCE Remove ARCH ARCHITECT (URAL) LB (Les) POUNDS(S) 12..1 TECHNOLOGY DRIVE, SETAtIKET,NY 11733 AWG AMERICAN WIRE GAUGE LL LIVE LOAD P. 631.689.8450 ( F. 631.639.8459 1 www.wfcaiaxom required by governing state law prior to start of work. J 0000 New Door T Telco Conduit AWS ADVANCED WIRELESS SERVICES LP LOW POINT A. Workmanship shall be of the highest quality and done by employees skilled in the LTE LONG TERM EVOLUTION 6. Each contractor shall be held to have visited the site and to have verified all existing practice of their trade. conditions prior to submission of bid. Notify the architect immediately and prior to progress Detail Nl u m b e r TA Elect ri c a I/Te I c o e M f of work if unusual field conditions arise. B. All work which fails to meet the standard as herein described, shall be replaced by the 1 Conduits BBU BASE BAND UNIT MAX MAXIMUM Contractor, at the Contractor's sole expense, including the work of others damaged by the A-1 Section Marker oBD BOARD MAIL MATERIAL 7. The Contractor shall verify and be responsible for all field dimensions and job conditions, initial failure or the corrective repairs. Ground Wire BLDG BUILDING MBD/MBDs MAIN DISTRIBUTION BOX(ES) y' and shall notify the architect of any discrepancies, conflicts, and/or omissions which would Drawing Page Conduit BILK BLOCK MECH MECHANICAL C. All items of work identified on the drawings b name, note, or material designation are Number B.O. BOTTOM OF MFR (D) MANUFACTURE (R) (D) interfere with the satisfactory completion of the work. Should the Contractor fail to follow this g Y g �+ Overhead Wire • . • . ', .�, •- procedure and continue with the work, the Contractor shall assume all responsibility and new, unless otherwise noted. BSMT BASEMENT MFR/MANUF MANUFACTURER (S) 1 BTS BASE TRANSCEIVER STATION MISC MISCELLANEOUS r':, �'-•' liability arising therefrom. SP-tot Elevation View Catch BUR BUILT UP ROOFING CONSULTANT: SAFETY & HEALTH PROVISIONS Basin/Drywell N 8. Where pipes, conduits or low tension wiring penetrate fire rated or sound rated c NIC NOT IN CONTRACT enclosures such as wall or slab, the spaces around such penetrations shall not exceed 1/2". A. The Contractor shall be responsible for initiating, maintaining, and supervising all safety 0000 Dooir Number Light Pole (�/CL CENTER LINE NO NUMBER pack spaces solid with mineral wool or approved equal on both sides of the rated enclosure precautions and programs in connection with the performance of the Contract. The CAB CABINET NOM NOMINAL to ensure full fire/sound rating in compliance with the local building code. Contractor shall take reasonable precautions for the safety of, and shall provide reasonable � x' x" Elevation CloD Utility Pole CB CATCH BASIN NTS NOT TO SCALE protection to prevent damage, injury or loss to employees executing the work and other `r B enichmark CDMA CODE DIVISION MULTIPLE ACCESS 9. In all cases, drawings shall not be scaled for information. Dimensions and conditions persons who may be affected thereby. The Contractor shall give notices and comply with CEM CEMENT o must be verified in the field. applicable laws, ordinances, rules, regulations, and lawful orders of public authorities Q-- Partition Type Tag Fire Hydrant CLR CLEAR (ANCE) OA OVERALL bearing on the safety of all persons and / or their protection from injury. The Contractor shall CLG CEILING OC (o.C.) ON CENTER 10. All new materials and installations shall be in accordance with the manufacturers latest erect and maintain, as required by existing conditions and performance of the Contract, COAX COAXIAL CABLE OD (O.D.) OUTSIDE DIAMETER printed specifications, and with all applicable node requirements reasonable safeguards for safety and protection, including erecting temporary barriers, 2 x 2 Ceiling Grid Sign CMU CONCRETE MASONRY UNIT OH OVERHEAD CNTR COUNTER OPNG OPENING posting danger signs and other warnings against hazards, promulgating safety regulations NO. DATE SUBMISSION 11. All work shall be performed in accordance with best standard trade practices. Each and notifying owners and users of adjacent sites, spaces, and utilities. COL COLUMN OPP OPPOSITE trade shall cooperate with other trades to facilitate job scheduling and completion. ELEC TRIC AL& MECHANICAL CONC CONCRETE 01 7/20/16 ISSUED FOR REVIEW B. All necessary precautions shall be taken b the Contractor, throughout the course of the Field Weld I- _GENU: CONST CONSTRUCTION 1 8/3/16 REVISED PER ATTORNEY COMMENTS rY p Y 9 S Smoke Detector CO NTR CONTRACT (OR) P 2 2/21/17 ISSUED FOR FILING 12. Proprietary names identifying items of work are used to designate the standard of project, to ensure that: Weld All Around CPT CARPET PCs PERSONAL COMMUNICATIONS SERVICES construction. Items of equal quality may be submitted for the architects review. CT CERAMIC TILE PL PLATE 1. Safe and proper ingress and egress from the building and all project areas will be 1/4» W e I d i n q Designation 0 Sprinkler Head CTR CENTER PL LAM PLASTIC LAMINATE 13. Each contractor shall be responsible for any damage to adjoining remaining areas as a maintained. CORR CORRIDOR PNL PANEL result of his work, and shall repair damaged surfaces to their pre-existing conditions or as Fillet Weld Weld Siz Hung Exit Sign PP POWER PANEL may be required to complete the entire scope of the work. 2. Fire protection and life safety components within the building will be properly , D PSI POUNDS PER SQUARE INCH maintained. DB(S)/(dB) DECIBELS) PVC POLYVINYL CHLORIDE 14. Alterations to existing work shall be patched and finished, as necessary, to match Wall Mounted Exit DEMO DEMOLITION existing contiguous surfaces or new finishes shown. 3. Structural integrity of the building will be maintained. Construction materials shall be Sign DEPT DEPARTMENT R spread out if placed on framed ceiling or roof members. Loads shall not exceed the DIA (�) DIAMETER RAD RADIUS 15. At the completion of each workday, each trade shall be responsible for cleaning up their design live load per square foot. Provide adequate shoring and or bracing where � Duplex Receptacle DIAL DIAGONAL RD ROOF DRAIN work. Rubbish removal shall be done in a dust inhibitive fashion, and the job site shall be structure has not attained design strength. DIM DIMENSION REF REFERENCE NO. DATE REVISION free of all debris and broom clean upon completion. � Quad Re c e pt a c I e DL DEAD LOAD REINF REINFORCED DN DOWN REQ'D REQUIRED KEY PLAN: 4. There will be no creation of noise outside the hours of 8:00 AM to 6:00 PM unless AREA OF WORK 16. Where applicable, clean all floors, walls, doors, misc., glass, etc. leaving job free of dust agreed to in advance, in writing, with the property owner. DP DAMP PROOFING RF RADIO FREQUENCY MATERIAL LEGEND: Light Switch DR DOOR RFCC RF CONCEALMENT POLE fEDAP 9iRCN ROAD�T R06o and debris, prior to project completion. DTL DETAIL RFG ROOFING 5. Building security shall be maintained in order to prevent unauthorized entry to the DWG DRAWING RIP RETIRE IN PLACE - 17. Existing equipment and materials to be removed, which are not required to be relocated premises and / or secured portions thereof. .• , ,, �. A:P Emergency Light (Existing ) DWR DRAWER RRH/RRHs REMOTE RADIO HEAD(S) or retained by the owner, shall become the property of the contractor and removed from the .. ' Con Crete RM ROOM remises. Electricity, and other utilities as applicable, shall not be interrupted during jr' ' E Ro ROUGH OPENING (uIN p 6. Water, Gas, � Emergency Light (New) construction, unless agreed to in advance, in writing, with the property owner. EA EACH 18. All concrete used for on-site construction :shall be air entrained, minimum 4,000 psi at 28 Steed Section EIFS EXTERIOR INSULATION FINISH SYSTEM S _ days, air entrained from 4% to 5%. 7. There will be no accumulation of dirt and dust. The contractor shall leave the area of Pendant Flood ELEC ELECTRIC (AL) work broom clean at the end of each day. Undiisturbed Light ELEV ELEVATION S SOUTH 19. Elevation 0'-0" is a reference of the existing grade height. Notation to heights will be EMDED EMBEDDED SCHD/SCH SCHEDULE N?P TED 3lAlE5 GOVEMAQ I Earth/Soil Smoke Detector EMERG EMERGENCY S from this elevation, unless otherwise noted. Q D STORM DRAIN Store/Gravel ENCL ENCLOSE (ENCLOSURE) SECT SECTION 20. Verizon Wireless will remove hazardous materials, including asbestos containingWIN EQ EQUAL SF SQUARE FOOT material(s) encountered throughout. If existing asbestos containing material is encountered Ib Existing Fire Extinguisher ETC ET CETERA SIM SIMILAR during the work, report this immediately to the Verizon Wireless construction manager for Galy. Steel Grating EXC EXCAVATE SPEC SPECIFICATION New Fire Extinguisher EXH EXHAUST SPR SPRINKLER EXIST/(E) EXISTING SQ SQUARE remediation. x x x x x x x x Ga I v.St e e l Diamond A SS (S/S) STAINLESS STEEL x x x x x x x x 21. Large scale drawings take precedent over small scale drawings. Detail drawings take x x x x x x x x Plate o New 4' Pendant Light F STD STANDARD precedent over large and small scale drawings. Brick Facade FCC FEDERAL COMMUNICATIONS STL STEEL COMMISSION STOR STORAGE 22. The Contractor shall be responsible for documenting existing conditions prior to start of ® Supply FD FLOOR DRAIN SUSP SUSPENDED " work. Documentation shall be in the form of electronic photographs and written description FDN FOUNDATION of existing damaged items, not specifically noted on construction drawings. Provide copies ZPeturn FE FIRE EXTINGUISHER T of this documentation to the architect & Verizon Wireless Construction Manager at start of FIN FINISH (ED) T TREAD work. Damaged items, not specifically noted nor visually observed in photographs, shall OS FIXT FIXTURE TEL TELEPHONE FACILITY NTE become the responsibility of the contractor. Contractor shall remove, repair and/or replace APPLICABLE CODES FLR FLOOR (ING) THK THICK (NESS) at their own expense. FP FIREPROOF TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION rORIENT POINT 2 M 1. New features labeled as such; all else existing or future by others. ALL CONTRACTORS WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL FPSC FIREPROOF SELF-CLOSING T.O. TOP OF 23. In the event of a discrepancy between drawings and specifications or between drawings CODES AS ADOPTED BY-THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. FT FEET T.O.S. T.O.S. (TOP OF STEEL) bring the discrepancy to the architect's attention immediately, in writing, for clarification. 2. The new public utility wireless communications facility will be unmanned and will be visited THE EDITION OF THE AHJI ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF FTG FOOTING TYP TYPICAL approximately once a month for maintenance purposes; therefore it is not anticipated to CONTRACT AWARD SHAL.L GOVERN THE DESIGN.THE FOLLOWING CODES ARE NOTED: 24. The Contractor shall take no advantage of an apparent error or omission in the generate additional traffic. u g Y pp g ■ 2015 INTERNATIONAL BUILDING CODE GA GAGE, GAUGE UL UNDERWRITERS LABORATORIES contract documents. in the event the contractor discovers such an error, or omission in them BUILDING/ZONING CODE FOR THE AHJ STATED ON SHEET T-100.00 GALV GALVANIZED UMTS contract documents, the contractor shall immediately notify the architect. The architect will 3. No additional parking is required for the new use, as this is an unmanned site. ■ 2015 INTERNATIONAL NAECHANICAL CODE GC GENERAL CONTRACT (OR) UON UNLESS OTHERWISE NOTED ORIENT, NY 11957 then make such corrections and interpretations as may be deemed necessary for fulfilling ■ 2015 INTERNATIONAL PLUMBING CODE GFI GROUND FAULT INTERRUPT UPS UNINTERRUPTED POWER SUPPLY the intent of the contract documents. 4. No solid or liquid waste will be produced by the new use, as this is an unmanned site. ■ 2015 INTERNATIONAL FUEL GAS CODE GHz GIGAHERTZ ■ 2015 INTERNATIONAL FIRE CODE GL GLASS, GLAZING y TITLE: 25. The Contractor is responsible for obtaining all required inspections. 5. No water or sewage facilities are required for the new use. ■ 2015 INTERNATIONAL ENERGY CONSERVATION CODE GND GROUND VCT VINYL COMPOSITE TILE ■ NATIONAL ELECTRICAL CODE 2011 GPS GLOBAL POSITIONING SYSTEM VIF (VA.F.) VERIFY IN FIELD GENERAL NOTES 26. The Contractor shall forward final close-out photos documenting all installed equipment, 6There will be no commercial or retail signsnor special lighting for the new site other than ■ NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)70 NATIONAL ELECTRICAL CODE 2011 GSM GLOBAL SYSTEM FOR(CATIONS MOBILE VZW/VW VERIZON WIRELESS . , mounts, connections, etc. of the completed installation at the antenna level including model ■ NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 58 LIQUEFIED PETROLEUM GAS CODE 2014 numbers, down tilts, etc. to the Architect upon completion minor maintenace lighting at the proposed equipment cabinets beneath the equipment weather (FOR PROPANE INSTALLATIONS) GWB GYPSUM BOARD WALL W canopy. W WEST DATE: JULY 13, 2016 CONTRACTORS WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING STANDARDS: H W/ WITH PROJECT NO: 14-10823 27. The Contractor shall provide shop drawings for dunnage and canopy steel fabrication. EGRESS NOTES HC HOLLOW CORE WD WOOD ■ AMERICAN CONCRETE;INSTITUTE (ACI)318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL HDR HEADER WFC WFC ARCHITECTS DRAWN BY: MM 28. Prior to the final inspection, the Contractor shall provide the following to the Architect: CONCRETE HDW HARDWARE WM WIRE MESH CHECKED BY: TM - Final redlined As-Built drawings 1. Maintain legal exit access for spaces being interrupted by construction. Provide 60" main ■ AMERICAN INSTITUTE (OF STEEL CONSTRUCTION (RISC), MANUAL OF STEEL CONSTRUCTION, HT/HGT HEIGHT W/O WITHOUT SCALE: AS NOTED - All third party inspections results aisles and a min. of 44" ASD, NINTH EDITION secondary aisles for employees to exit space in case of an HM HOLLOW METAL WWM WELDED WIRE MESH - clear digital photos on disk or via email emergency when working within buildings. Maintain aisles free and clear from obstruction. ■ ANSI TIA/EIA 222-F (REV'G'WHERE APPLICABLE MUNICIPALITIES REQUIRE), STRUCTURAL HP HIGH POINT WWF WELDED WIRE FABRIC DRAWING NO: - Generator start up report (When generators are installed) Provide temporary exit diagrams, mounted in conspicuous locations for all to see. STANDARDS FOR STEEL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES: HTG HEATING ■ TIA 607, COMMERCIAL (BUILDING GROUNDING AND BONDING REQUIREMENTS FOR HVAC HEATING VENTILATION - Certificate of Electricians Certificate and grounding test verification 2. Maintain exit and emergency lighting for adjacent occupied or tenant spaces during the ■ELECOANSIT MUNICATIONS FOR TELECOM - DC POWER SYSTEMS-TELECOM, ENVIRONMENTAL PROTECTION & AIR CONDITIONING course of construction. Should any of these systems require shutdown, notify the Verizon ■ ANSI ICC A117.1-2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES SHEET NO: 2 OF 10 Wireless project manager, in writing, with 72 hour notice. 1 0 ICC/ANSI 117.1 -2009, ACCESSIBILITY CODE NOTES: 1. CONTRACTOR IS TO RESTORE ANY AREA WHICH IS AFFECTED BY THE FLOW WIRE FENCING WIRED OR INSTALLATION OF ANY ITEMS AND/OR EQUIPMENT WITHIN THIS SCOPE OF STAPLED TO POS II II II WORK. (14-1/2 GA., 6"X6" MESH) I II I II ( II C,?� �I II II II II II BALES TO BE SET \ 2. CONTRACTOR TO PROVIDE SITE SPECIFIC SIGNAGE IN ACCORDANCE WITH STAKES TYP. \ VERIZON WIRELESS PROJECT TECHNICAL SPECIFICATIONS FOR SITE SIGNAGE. • BOTTOM OF DRAINAGE FILTER FABRIC (MIRAFI (TYP.) ON GRADE • CHANNEL OR SLOPE 140N OR EQUAL) ATTACHEEDETO (SEE SECTION) ELEVATION (SEE SECTION) �'�'�\O��G� T3.HAT ALL TRN CES TO BE HAND EXCAVATED AND BACKFILLED TO ENSURE / . WIRE FENCING, TIES WOOD �� G UNDERGROUND UTILITIES ARE NOT DISTURBED. MAKE ALL PVC \ JOINTS WATERTIGHT. TEST PRIOR TO BACKFILLING. a` FENCE TO BE ANGLED SPACED 24 " C-C, POST " TOWARD SLOPE IN TOP AND MID SECTION ? \ DRAINAGE CHANNEL BUILDING WIRE OR 4. THE CONSTRUCTION AND PLACEMENT OF THE FACILITY WILL NOT �p INTERFERE WITH PUBLIC SAFETY COMMUNICATIONS AND THE USUAL AND TWINE (TYP.) 2 X 2 STAKES POSTS (TYP.) (TWO EACH BALE CUSTOMARY TRANSMISSION OR RECEPTION OF RADIO, TELEVISION OR OTHER N COMMUNICATIONS SERVICES OR WITH ELECTRICAL TRANSMISSION LINES. '=y^ COMPACTED 14" x 18" x 36" \ " BACKFILL STRAW ®ALES \ 5. EXISTING TREES, LOW LYING VEGETATION, TRAILERS AND BOATS IN AREA S��A° 6"X6" TRENC OF NEW CONSTRUCTION TO BE CLEARED PRIOR TO START OF ` _\ SLOPE EXISTING OVERHEAD CONSTRUCTION. I�—III— RADE UTILITY LINES FROM SILT FENC Trf� � — — ' 6. 1ALL NEW LANDSCAPING SHALL BE PLANTED TO PROVIDE CONTIGUOUS A R C. H. I T E C T S GRADE \ UTILITY POLE 35 # SCREENING TO THE NORTH AND WEST OF THE NEW EQUIPMENT AREA. BEYOND a a 12.1 TECHNOLOGY DRIVE, SETAUKET,NY 11733 •�"_ � — 7. LANDSCAPING TO BE KEPT IN GOOD/HEALTHY CONDITION AND SHALL BE P. 631.689.8450 1 F. 631.689.8459 1 www.wfcaia.com DRAINAGE CHANNEL 111=ILII = — .�• .,� 6" PENETRATION INTO OR SLOPE COMPACTED BACKFILL i' �s� REPLACED SHOULD ANY TREE(S) DIE AT ANY POINT DURING THE DURATION GROUND(SEE SECTION) .2 �• OF THE SITE BEING IN USE. _ •� E NOTE: PERIODIC MAINTENANCE IS REQUIRED AS NEEDED TO FENCE AND FABRIC TO / gr c \ " REMOVE ACCUMULATED MATERIALS AND REPAIR FENCE. EXTEND INTO TRENCH / ' $O 00 °� \ W HAY BALE DETAIL • / i EROSION CONTROL MEASURES SILT FENCE DETAIL 4 3 SCALE: N.T.S. f SCALE: N.T.S. SE�,'i70N / �� s �� 1. DURING THE COURSE OF CONSTRUCTION CERTAIN EROSION AND /' U� ��c 0 \� SEDIMENT CONTROL MEASURES MAY BECOME NECESSARY TO PREVENT THE ? /' \�� ♦ �� TRANSPORT OF SEDIMENT TO OFF-SITE AREAS, PONDS, WATER COURSES, NOTE: DRAWINGS DEPICT THE INSTALLATION OF NEW VERIZON WIRELESS ANTENNAS, CABLES AND ETC. THAT SHALL BE MOUNTED WITHIN A DRAINAGE INLETS, RECHARGE BASINS, WETLANDS, ETC. ACTUAL EROSION F CONTROL MEASURES WILL BE DICTATED BY FIELD CONDITIONS AS NEW 20 EXTENSION TO THE EXISTING CONCEALMENT POLE. A STRUCTURAL ANALYSIS SHALL BE PERFORMED BY A NEW YORK STATE / g� CONSTRUCTION PROGRESSES, BUT THE FOLLOWING GENERAL CONDITIONS LICENSED PROFESSIONAL ENGINEER (NOT WFC). SIGNED AND SEALED DOCUMENTATION FOR THIS WORK SHOULD BE FILED SEPARATELY AND QO ' SHALL BE OBSERVED:CONCURRENTLY WITH WITH THESE DOCUMENTS. ALL SUCH WORK HAS BEEN PERFORMED BY OTHERS (NOT WFC). �. CONSULTANT: PROPERTY LINE, TYP. O A. EXISTING VEGETATION TO REMAIN SHALL BE PROTECTED AND / v� REMAIN UNDISTURBED. WETLANDS DELINEATION SHOWN HEREON IS BASED UPON A SURVEY PREPARED BY: NYSDEC Freshwater Wetlands /' ♦ \ s. B. CLEARING AND GRADING SHALL BE SCHEDULED SO AS TO HAWKINS WEBB JAEGER PLLC, 560 WALT WHITMAN ROAD, MELVILLE, NY 11747, (631) / MINIMIZE THE SIZE OF EXPOSED AREAS AND THE LENGTH OF TIME o THAT AREAS ARE EXPOSED. 732-7777, (LAST DATED NOVEMBER 15, 20114 PROJECT N0: 06-0099). SURVEY AND EXISTING -( / X00 � C. THE LENGTH AND STEEPNESS OF CLEARED SLOPES SHALL BE WETLAND DELINEATION ORIGINALLY PERFORMED ON APRIL 6, 2006 STORAGE ���" ���� / ./ / os p / �� 0\ MINIMIZED TO REDUCE RUNOFF VELOCITIES. �� cj �� D. RUNOFF SHALL BE DIVERTED AWAY FROM CLEARED SLOPES. �O ��` /,•/ + / ..V�. 1 E. SEDIMENT SHALL BE TRAPPED ON THE SITE. 0�,/ ��O ♦ � � o / SPECIFIC METHODS AND MATERIALS EMPLOYED IN THE INSTALLATION AND '1°' +/ D� / MAINTENANCE OF EROSION CONTROL MEASURES SHALL CONFORM TO "THE �� �� Q .`� �/ ',1• `� NEW YORK GUIDELINES FOR EROSION AND SEDIMENT CONTROL". NEW VERIZON WIRELESS ELECTRIC CONDUITS TRENCHED �¢ � '�P� ��P ��� +/ 6gtk � `¢p,� oc �� NO. DATE SUBMISSION UNDERGROUND FROM NEW VERIZON WIRELESS ELECTRICAL METER 4 / �' EXISTING �y 2• SEDIMENT BARRIERS (SILT FENCE, HAY BALES OR APPROVED EQUAL) 0 7/20/16 ISSUED FOR REVIEW �(� Q G �, / Q p SHALL BE INSTALLED AS REQUIRED ALONG THE LIMITS OF DISTURBANCE AND DISCONNECT SUPPORT RACK TO NEW VERIZON WIRELESS MARINA FOR THE DURATION OF THE WORK. NO SEDIMENT FROM THE SITE SHALL 1 8/3/16 REVISED PER ATTORNEY COMMENTS ELECTRICPANELMOUNTED ON NEW ELEVATED EQUIPMENT y �GjV,` \� OF/' i I ��O -r // o / BE PERMITTED TO WASH ONTO ADJACENT PROPERTIES, WETLANDS OR 2 2/21/17 ISSUED FOR FILING PLATFORM �G ��� �,/ +/ o y I �+ ¢\. /// +�c. '� / ROADS. Q NEW 14'-0" HIGH X 6'-0" WIDE EASTERN RED �' �� st ' 3. GRADED AND STRIPPED AREAS AND STOCKPILES SHALL BE KEPT CEDARS AT 6'-0" O.C., TYP. OF (9) I� I JOS / ►�� / STABILIZED THROUGH THE USE OF TEMPORARY SEEDING AS REQUIRED. / SEED MIXTURES SHALL BE IN ACCORDANCE WITH SOIL CONSERVATION CLOSEST DISTANCE BETWEEN LIMITS OF 6 c /3 SERVICE RECOMMENDATIONS. CLEARING AND WETLANDS / /•' �� �� ��� ��®' / �o /O 4. DRAINAGE INLETS INSTALLED AS PART OF THE PROJECT SHALL BE /'• ` s �'� EXISTING / o,c 7r PROTECTED FROM SEDIMENT BUILDUP THROUGH THE USE OF SEDIMENT NEW VERIZON WIRELESS EQUIPMENT CABINETS �o i�i � �o �,� TRANSFORMER, METER + �o� /03• BARRIERS, SEDIMENT TRAPS, ETC., AS REQUIRED. MOUNTED ON NEW ELEVATED GALVANIZED STEEL , !'° ti� R p AND DISCONNECT / •rn0 5. PROPER MAINTENANCE OF EROSION CONTROL MEA PLATFORM. SEE ,'�,/A-100.00 FOR MORE /` s �� � ,� o�� �p.�. / SURES IS TO BE %� ���' �q EXISTING RESTAURANT AND ��'� PERFORMED AS INDICATED BY PERIODIC INSPECTION AND AFTER HEAVY OR INFORMATION / y PROLONGED STORMS. MAINTENANCE MEASURES INCLUDE, BUT ARE NOT NO. DATE REVISION /' �, �•� �pS�s� MARINE FUELING STATION ��.�d / /• LIMITED TO, CLEANING OF SEDIMENT BASINS AND TRAPS, CLEANING OR / �•,, 'So K<`o REPAIR OF SEDIMENT BARRIERS CLEANING r? � S � , AND REPAIR OF BERMS AND KEY PLAN: / + 9� �' �` / / DIVERSIONS, AND CLEANING AND REPAIR OF INLET PROTECTION. AREA OF WORK EXISTING CBF" COMPATIBLE i S 9 �yG Q / CONCEALMENT POLE WITH NEW 20'-0" / / ogi iii EXTENSION / /'� `LO �•� A�> tij /+ ./y 6. APPROPRIATE MEANS SHALL BE USED TO CONTROL DUST DURING Ao` CONSTRUCTION. _ 7. A STABILIZED CONSTRUCTION ENTRANCE SHALL BE MAINTAINED TO PREVENT SOIL AND LOOSE DEBRIS FORM BEING TRACKED ONTO LOCAL \a'• �� �•!�/ �'��� o`d'� + ROADS. THE CONSTRUCTION ENTRANCE SHALL BE MAINTAINED UNTIL THE min mirmill E SITE IS PERMANENTLY STABILIZED. /+ 8. SEDIMENT BARRIERS AND OTHER EROSION CONTROL MEASURES SHALL = REMAIN IN PLACE UNTIL UPLAND DISTURBED AREAS ARE PERMANENTLY / •�Q �'4' n � �• ♦ ���` G�gO Q LINE ( --"-- — ) /I/ STABILIZED, AFTER PERMANENT STABILIZATION, PAVED AREAS SHALL BE x- �' �q REPRESENTS LIMITS OF Q. + CLEANED AND DRAINAGE SYSTEMS CLEANED AND FLUSHED AS NECESSARY. � ��• 1h F�` �,P CLEARING, GRADING AND ZEXISTING ry pOH GROUND DISTURBANCE J� // 9. CONSTRUCTION ACTIVITY POLLUTION PREVENTION NOTE: 60'-9" ` �„„�P` // .� EROSION AND SEDIMENTATION CONTROL PLAN SHALL CONFORM TO THE R14p•_0� ! MARINA �� `��'' �'� 1 EROSION AND SEDIMENTATION REQUIREMENTS OF THE NYSDEC SPDES r a� / �� •� GENERAL PERMIT FOR STORMWATER DISCHARGES FROM CONSTRUCTION ' ♦y;. �i Q I r / �� �� ACTIVITY. �O • V I r / / G Q� 10. THE CONTRACTOR SHALL USE HAY BALES, SILT FENCE OR OTHER I s NYSDEC i al Wetlan r r + INTO DRAINAGE MEANS TO PREVENT SCDIMENT AND DEBRIS FROM WASHING cA I / •`� A NAGE INLETS. EROSION CONTROL MEASURES SHALL BE IN I 0�+ >> r r / / ��Q` G�� ACCORDANCE WITH THE NEW YORK STATE GUIDELINES FOR URBAN EROSION �Q. AND SEDIMENT CONTROL. 13 11. ALL TOPSOIL TO BE PLACED MUST BE PROVIDED BY CONTRACTOR. p o + J \ "y ` O� ♦ �yT Q�/ \�" 12. TAKE MEASURES TO PREVENT POLLUTING AIR WITH DUST AND // '� 7m PARTICULATE MATTER / + + ♦ .�j° e ?� X �/ 13. ALL SLOPES GREATER THAN 1:3 SHALL RECEIVE EROSION CONTROL O�6 ♦ ^ / �� Q��`j / STABILIZATION FABRIC. REFER TO GRADING AND DRAINAGE PLAN AND 1 �* / + LANDSCAPE PLAN FOR ADDITIONAL INFORMATION •� / �, \. / L� NEW 14 -0 HIGH X 6 -0 WIDE N M F ♦ �� ` 6o�Ay 9 / EASTERN RED CEDARS AT 6'-0" O.C. ORIENT POINT 2 + STORM WATER RUN-OFF MANAGEMENT PLAN `2 sFcjo / NOTE: 9 ♦ A-100 '� / SHRUBS SHALL BE SET PLUMB. REMOVE TWINE 1. ALL STORM WATER RUN-OFF GENERATED BY THE NEW DEVELOPMENT J ♦ / /+ I FROM AROUND TOP OF ROOT BALL LEAVE SHALL BE CONTAINED WITHIN THE PERIMETER OF THE NEW CONSTRUCTION. ' �y1 / ��� // 4 DEEP BURLAP IN PLACE, ROLL BACK 1/3 OF BURLAP SHREDDED WOOD 2. ALL CONSTRUCTION ON SITE SHALL BE PROTECTED BY HAY BALE AND 40200 MAIN ROAD O��♦ ` _ / e �°\ s /-I- CHIP MULCH (REMOVE, UNLESS BIODEGRADABLE.) SILT FENCING PURSUANT TO THE MINIMUM REQUIREMENTS OF THE NY EXISTING BOAT 12„ STATE STORM WATER DESIGN MANUAL. THESE FEATURES SHALL REMAIN IN ORIENT, NY 11957 PLACE UNTIL THE CONSTRUCTION SITE HAS BEEN PERMANENTLY STABILIZED + LAUNCH RAMP ON ALL SIDES 6" SOIL SAUCER NOTE:- TO PREVENT EROSION. 348.41' �� ��ti `� INFORMATION SHOWN HEREON IS BASED UPON A SURVEY PREPARED BY: TITLE: p Q 0 s. ♦p HAWKINS WEBB JAEGER PLLC, 560 WALT WHITMAN ROAD, MELVILLE, NY 11747, 3. ALL WORK MUST CONFORM TO FEMA FLOOD ZONE REQUIREMENTS. / , (631) 732-7777, (DATED NOVEMBER 15, 2014 PROJECT NO: 06-0099) NYSDEC 7'• �� EXISTING ARCHITECTURAL SITE PLAN oda' \ /\\X./ ZONING TABLE LATITUDE: 41.15294 (NAD 83) Wetlands �� � _ _. _ _ + /\\/ . Sag• 44'40-W \/\\\ •. \//\\� - LONGITUDE: -72.24419 (NAD 83) DANE: JULY 13, 2016 EXISTING BAY FINISHED // / • . //\/ BULK ZONING REQUIREMENTS § 280 56 FOR MARINE II ZONING DISiRI(_T ELEVATION: 5' +/-AMSC NGVD29 A pNRq� ENTRANCE GRADE \\\ ; • \\\\� ( ) PRiOJECT NO: 14-10823 RS R �/ � �//// :, j/// REQUIRED NEW TAX MAP INFO:: SECTION 15, BLOCK 9 AND LOT 8.1 DRAWN BY: MM EXISTING SHORELINE \ _ ZONING DISTRICT: 1000 ROLL BACK ,// / ��\//\/ §280 56 MAXIMUM HEIGHT: 35 /2 STORIES 20 (89 TOTAL MONOPOLE) CHECKED BY: TM BURLAP 1/3 \\j\\\\\\\\\\\\\\\\\\�\\�\\\� §280-56 MINIMUM FRONT YARD: 35' 694'-7" ZONING DESIGNATION: MARINE II SCALE: AS NOTED LEG /,� /,� /,� /,�///,�///,� /,�///.� / (COMPOUND) DRAWING NO: —A—A— ANTENNA CABLE BACKFILL TOPSOIL §280-56 MINIMUM REAR YARD: 25' 197'-8" (COMPOUND) 0' 20' 40' 80' ARCHITECTURAL SITE PLAN E E ELECTRIC— TELCO ONDUIT CONDUIT TREE PLANTING DETAIL 0 ZOU-� WITH §280-56 MINIMUM SIDE YARDS: 25' 7'-3" (COMPOUND) 1 T E T E— TELCO & ELECTRIC CONDUIT FERTILIZER AT §280-56 AGGREGATE SIDE YARDS: 50' 250'-11" 1 -40 -0 SCALE = 1 " = 40'-0" SCALE = N.T.S. THIE RATE OF 5 (COMPOUND) NORTH SHEET NO: 3 OF 10 LB'S. PER YARD 177177, NEW VERIZON WIRELESS ICE BRIDGE WITH (12) NEW LEASE 7/8"0 ANTENNA CABLES 9:. DASHED LINE REPRESENTS NEW VERIZON WIRELESS WEATHER (3) NEW VERIZON WIRELESS MAIN DISTRIBUTION BOXES MOUNTED TO NEW UNISTRUT CANOPY ABOVE •:` 12 X12 -0 SITEPRO GRIP-SPAN ICE FRAME. SEE DETAIL 2/A-103.00 & 1/A-104.00 BRIDGE KIT (MODEL#IB24D-V) WITH o NEW VERIZON WIRELESS EQUIPMENT CABINETS ATOP NEW STEEL DUNNAGE EQUIPMENT (12) NEW VERIZON WIRELESS RRH UNITS (STACKED) MOUNTED TO Z-BRACKET TRAPEZE OR EQUAL NEW UNISTRUT FRAME. SEE DETAIL 4/6-103.00 PLATFORM WITH NEW WEATHER CANOPY ABOVE. SEE DETAIL 5/A-103.00 k q NEW VERIZON WIRELESS 1OKW DIESEL DC GENERATOR WITH SOUND ENCLOSURE P C NEW VERIZON WIRELESS STEEL STAIR SET ATOP NEW ELEVATED STEEL DUNNAGE EQUIPMENT PLATFORM (54 GAL. Ji 00-03 C ---- DIESEL TANK CONTAINED WITHIN GENERATOR ENCLOSURE) SEE DETAIL , 2/E-100.00. PROVIDE A GALV. STL. SPILL CONTAINMENT PAN BENEATH THE II (6) NEW ANTENNA COAX CABLES SECURED TO r GENERATOR WITH SLEEPER BEAMS er i' Z-TRAPEZE WITH NEW SNAP-IN HANGERS (TYP.) O x x x x x x x x x x x x x x x x x x x (3) NEW VERIZON LZ WIRELESS SECTOR > x' f ANTENNAS AND, (6) Y RR RRH DB MDB MDB I O NEW DIPLEXERS w 1 ; , ; RRH RRH EXISTING AT&T EQUIPMENT Z MOUNTING WITHIN a PLATFORM j < O NEW 20' EXTEI`NSION i i x t., O - 1 : o • . ! I I 2-1 TECHNOLOGY DRIVE, SETAUKET,NY 11733 N (n OF EXISTING I I I; il . 1 � � � ._13:..(. : . ' I! : . � I. � ' ' ' ;. I�I� x €"" P. 631.689,8450 1 F. 631.689.3459 ( wxv,.v.utfrnia.com Li Z MONOPOLE \� I �, , 1'_ ; � . I I v ! I GENERATORIF I II I 3 `: t 'W# 9712 W WATERPROOF SEALANT I} BATTERY x EXISTING 3/4" CHAMFER I I I I; CONCEALMENT ENODE : o LLJ I e e e z POLE WITH NEW I I - I FULLY SHIELDED FL IP 0 20 -0 EXTENSION : .. .. _. .W I LIGHTS MOUNTED TO WEATHER CANOPY POSTS FRONT . :( I �� yy { fi 1 < I...i i 1.^ BENEATH WEATHER PAINT PORTIONS OF POST TO BE UP CANOPY. TYPICAL FOR 3 . n :. �. . e e e o x ( ) �_�i �3 , s ( _ I 13 '° I ' i w; ' x V `. '•r^� , EMBEDDED IN CONCRETE WITH CUT-BACK REFER TO DETAIL ! fi f E PAINT TYPICAL. - ASPHALT _ , . ' ' � i. E � 11= d- I I 3/A 104.00 _ � � ! _ U L NT I CONS TA ' I I i I i NEW DC GENERATOR i I .71 , III ! i 1 - - DISCONNECT t ....j.,..�.. a... ..i. III . • III � x ( x POURED CONCRETE FOOTING, SET PIPE MOUNT _I I I- ;, •- �•I �=r AS INDICATED WITHIN. CONTRACTOR TO 1= I I I ,} TELCO 'DE-WATER' TRENCH AS REQUIRED DURING III a I I= ( I „•._ 1 INSTALLATION OF CONCRETE TO ENSURE =III III PROPER INSTALLATION STRENGTH. CONCRETE TO I ° II-I z 1 + 1 x 1 1 1 1 1 1� ` x ACHIEVE A COMPRESSIVE STRENGTH OF 3,000 �I I I .° ° I II II LBS. @ 28 DAYS, AIR ENTRAINED - x x x x �- x x x x x --L�ic x x x ctL x x x x �e7— x x 26'-0" ° � I1=1 UNDISTURBED EARTH =I I ° a I I „` x ° GRADE WITHIN FENCED AREA TO BE 32'-0" II I I °.p I II II FINISHED WITH 4" CRUSHED STONE 12" 0 SONOTUBE FORMED CONCRETE BASE II II= OVER LANDSCAPE FABRIC NO. DATE SUBMISSION =1 I I a �: • a° �I + (4) NEW VERIZON WIRELESS GPS UNITS MOUNTED TO NEW 0 7/20/16 ISSUED FOR REVIEW X WEATHER CANOPY =III I I= 1 8/3/16 REVISED PER ATTORNEY COMMENTS III _ NEW 4'-0" WIDE SWING GATE k NEW CHAIN LINK FENCING WITH PRIVACY SLATS 2 2/21/17 ISSUED FOR FILING NEW CANOPY POST, TYP. FOR (6) NEW VERIZON WIRELESS TELCO CONDUIT TRENCHED FROM NEW INSTALL NEW EXTERIOR FIRE EXTINGUISHER CABINET BY JONSECO, VERIZON WIRELESS TELCO CABINET TO EXISTING MESA SPAN M/N JBXE83 OR APPROVED EQUAL ATTACHED TO PLATFORM CABINET WITHIN EXISTING AT&T COMPOUND rr » RAILING AND PROVIDE LARSEN S FIRE EXTINGUISHER MP-20 (10) NEW VERIZON WIRELESS HELICAL PILES(t20' 12" DEEP/CONCRETE PIERS WITH CONTINUOUS CONCRETE PILE CAP) SEE DETAIL 1/A-101.00 NOTE: CONTRACTOR SHALL FURNISH (1) ICE BRIDGE DETAIL ENLARGED EOUIPMENT PLAN 6' LADDER, FOLDING TABLE AND FOLDING 8" 1'-4" 2'-8" 4 n CHAIR AND CHAIN TO PLATFORM RAILING I ®" I SCALE = 1 = 1 —0 G SCALE = 3/8 = 1 —0 UPON CONSTRUCTION COMPLETION 3�8 1'-OilNORTH NO. DATE REVISION KEY PLAN: AREA OF WORK (12) NEW VERIZON WIRELESS 7/8"0 ANTENNAS CABLES ROUTED WITHIN EXISTING 4'-0" RAIL/8'r O.D. TOP CONCEALMENT POLE NEW TREES AROUND BACK AND SIDES OF NEW VERIZON WIRELESS COMPOUND TO - - - - - - - MATCH EXISTING TREES AROUND AT&T COMPOUND. REFER TO SITE PLAN tltzr.ovc rsv.vo sr.sn r..r rn�n 11SP-100.00 AND DETAIL 2 SP-100.00 PROVIDE DIAGONAL E NEW 13'-0" HIGH CHAIN LINK FENCING WITH PRIVACY SLATS BRACES AS (4) NEW VERIZON WIRELESS GPS UNITS MOUNTED TO NEW WEATHER CANOPY REQUIRED, TYP. - z NEW VERIZON WIRELESS EQUIPMENT CABINETS AND 1 OKW DIESEL DC 0 N a GENERATOR WITH SOUND ENCLOSURE SET ATOP NEW ELEVATED GALVANIZED STEEL PLATFORM bi r__1r� ui w z Q 0 NEW TREES (BEYOND) AROUND BACK AND SIDES OF NEW VERIZON WIRELESS - Lu ¢ z ° COMPOUND TO MATCH EXISTING TREES AROUND AT&T COMPOUND. REFER TO SITE o w z Z a Q PLAN 1/SP-100.00 AND DETAIL 2/SP-100.00 J ¢ W z z TENSION BAR. Z �_ N EXISTING AT&T FENCED IN EQUIPMENT AREA TO REMAIN o 1 5/8" TOP RAIL. o J W W ~LLj ~ 0 a ¢ Z EXISTING TREES AROUND EXISTING AT&T COMPOUND TO o � 0 z REMAIN I I 0 N v �i � w CHAIN LINK FENCE SYSTEM WITH z w p ¢ ¢ -t LATCH WITH PERMAHEADGE VISION BLOCKING/ IV z PADLOCKING ANTI CLIMB SLATS g > C) z Z o ,, r " , ' _� PROVISIONS. ui LL_ W w w ¢ U k `;' "'�;:' ^/ V%, rJ 2" DIA. GATE LINE AND CORNER POSTS 0 O OLL_ +I cn .: T�> .T FRAME. 2 1/4" O.D WITH 10'-0" Z O O W ' w 0_ o 0 w B O.C. MAX. SPACING. i— F— F O' ;f n �, r� r� r� r� 4 THK. LAYER OF 3/4" N N ' r X , 2" DIA. BRACE ORIENT POINT 2 • � STONE OR GRAVEL. Q ¢ ¢ Q Q ¢ p c,c w (NP)• 1,-Orr +I -H -H -H +I H N : , •� z 1 5/8" BOTTOM RAIL. 10 Fr 0 (o W 0 0 0 W \ \ N 3" O.D. GATES \ POSTS. MIRASCAPE FILTER o) oo _t m o :x ^. 00 00 00 CO cD to .. 4 r; F J FABRIC TYP. 40200 MAIN ROAD h 4" STONE OR GRAVEL. I I I I I I IL-11 Li 1 BOTTOM O.D. N ORIENT, NY 11957 I I ( I e ( ENSIO RAIL / TENSION WIRE I I I I I I LT T T T T E E E E E E E E E E E — ° s OPTIONAL). '\\�/\\ I I I I ( I I ( Izzz z:z .�1'-0"0 SONOTUBE I. . . I TITLE: I I I I I I ^q I . I FORMED CONCRETE I ,I I.a �\ EAST ELEVATION, I I � z �. I I �. I FOOTINGS. I .. I I .I �// a I I ' , / L L_J L-� -H . I I Io 2x6 PRESSURE ENLARGED EQUIPMENT PLAN AND - I ` TREATED LUMBER SET / ei I FENCING DETAILS PAINT PORTIONS OF j POST TO BE EMBEDDEDI. • I I' I 12" OUTSIDE OF NEW EXISTING FENCING NEW FENCING IN CONCRETE WITH I°° I '. I I FENCE LINE. Lp DATE: JULY 13, 2016 1 I CUT—BACK ASPHALT I �I U PAINT, TYPICAL. u / 1 � . I 1'-0"� SONOTUBE FORMED e PROJECT NO: 14-10823 (10) NEW VERIZON WIRELESS HELICAL PIILES(f20' L- 4 L J CONCRETE FOOTINGS. �//\�//�/ DRAWN BY: MM NOTE: DRAWINGS DEPICT THE INSTALLATION OF NEW VERIZON WIRELESS ANTENNAS, CABLES AND ETC. THAT SHALL BE MOUNTED WITHIN A NEW 20' EXTENSION TO DEEP/CONCRETE PIERS WITH CONTINUOUIS CONCRETE PILE FENCE FABRIC SHALL BE GALVANIZED STEEL MESH 9 GAUGE WITH PRESSURE TREATED THE EXISTING CONCEALMENT POLE. A STRUCTURAL ANALYSIS SHALL BE PERFORMED BY A NEW YORK STATE LICENSED PROFESSIONAL ENGINEER (NOT WFC). SIGNED CAP 2" OPENINGS. FENCE POSTS SHALL BE 2 1/4" OUTSIDE DIAMETER. WOOD STAKE AT 4' O.C. CHECKED BY: TM AND SEALED DOCUMENTATION FOR THIS WORK SHOULD BE FILED SEPARATELY AND CONCURRENTLY WITH THESE DOCUMENTS. ALL SUCH WORK HAS BEEN PERFORMED GALVANIZED STEEL, SCHEDULE 40. TOP AND BOTTOM RAILS SHALL SCALE: AS NOTED BY OTHERS (NOT WFC). BE 1 5/8 OUTSIDE DIAMETER ,SCHEDULE 40. FENCE POSTS SHALL NEW CONCRETE FOOTING. DRAWING NO: BE SPACED A MAXIMUM OF 10'-0" INCHES ON CENTER. NOTES: FURNISH AND INSTALL SWING GATE AND ALL NECESSARY "' " HARDWARE AND STIFFENERS REQUIRED TO PROVIDE A EAST ELEVATION 0 1 -4 2-8 5-4 TYPICAL FENCE DETAIL COMPLETE CHAIN LINK GATE INSTALLATION. AIM 100000 1 PROVIDE PRIVACY SLATS TO MATCH EXISTING SCALE = 3/16" = 1 '-0" 3/16"=1"-0" SCALE = 1/2" = 1 '-0" ADJACENT FENCING SHEET NO: 4 OF 10 E- A-101 (2) 3/4" A325 GALV, STEEL BOLTS, NEW 1 -1/2"0 PILE WITH 10"/12"0 NEW W12 X 26 NUTS AND WASHERS, TYP. PER CONNECTION HELICES, TYP. FOR (10) (2) GALV. STEEL L4x4x5/15x6" LONG CLIP ANGLES, 32'-0" TYP. PER CHANNEL 1 2" 4'-4" 8'-5" 8'-8" 8'-8" �12st 1 4 0 12"x12"x3/4" STEEL PLATE WITH (2) 1/2"0, lo lo 0 12" LONG ANCHORS WELDED TO BOTTOM OF x x x x IX PLATE. PROVIDE 2 HOOK AT BOTTOM ° ° d d '''' ,•: / v C - /° . d . d d °. I a v N , / A \ d /4''!' �d ad ' ' v 7/'—_ v v °°' d ° °. d v d d NOTE: #4s @ 12"O.C. d o d o a R H T E T TOP OF PIER ELEVATION TO BE Z_ "I d a SET AS INDICATED IN PLAN O p >> d #6 DOWELS WITH STANDARD ° °:' ° d d ° d 12-1 TECHNOLOGY DRIVE,SETAUKET,NY 11733 Z a 2 4 ' 90' HOOK Q. a° d .d v °'. ° ° a P. 631.689.8450 I F. 631.689.8459 1 i"vw.wfcaia.com g -H 1'-6"0 CONCRETE PIER v ° d a • ° v: d ° J r LiJ x ° v d 4" CRUSHED STONE OVER d d 2 —0 p LANDSCAPE FABRIC d ° d v o Q TYP. X a d ° d O 7 4 , . a cd ° 1r/ C(ONSULTANT: _ V^ a v d I _.._.. ° . . A d v j� d d° °d d a d ° —� x l a d v d v d 4 �. d d O ad• v • v ° d .. d v d ° .. d d ° B o ° ° I } d o ° ° v o a. vd ° ° d v ° d N d �. /X v v d 'v n d c d v v° ' x x x x x x x x x x x --�a�x x x x c��— x x x x –Ls^>— x x (4) #6 BOTT. CONTINUOUS NEW 1-1/2"0 PILE WITH 10",/12"0 x HE N ULTIMATE -- MIN. 24"x16" CONTINUOUS POURED 0' EMBEDMENT) C CONCRETE PILE CAP NO. DATE SUBMISSION 6"x6"x3/4" STEEL PLATE CAP + x 12"X12"X 3/4" BEARING PLATE, 0 7/20/16 ISSUED FOR REVIEW �" BOLTED OR WELDED TO SHAFT \ TYP. (1) PER PIER 1 8/3/16 REVISED PER ATTORNEY COMMENTS X 2 2/21/17 ISSUED FOR FILING 18"0 SONOTUBE PIER, TYP. FOR (10). SEE DETAIL 1/A-101.00 FOUNDATION NOTES HELICAL PILE SPECIFICATIONS AND NOTES CONTRACTOR TO PROVIDE ALL REQUIRED SUPERVISION, LABOR, MATERIALS, FOUNDATION PLAN 8" -4" 2'-8" 1. ALIGN BEARING PLATES IN CENTER OF EACH PIER. TOOLS AND EQUIPMENT FOR INSTALLATION OF HELICAL STEEL ANCHOR PIERS AS NO. DATE REVISION 2. 4LL PIERS TO BE LEVEL WITH EACH OTHER. (SEE PIER SECTION FOR METHOD INDICATED ON THE DRAWINGS. RELATED WORK INCLUDING EXCAVATION, SCALE = 3/8" = 1 '-0" 3/8"=1'-0" NORTH BACKFILLING, TEMPORARY PROTECTION AND SHORING AND REINFORCED CONCRETE KEY PLAN: OF DETERMINING TOP OF PIER) WORK. AREA OF WORK 3. ALL CONCRETE USED FOR ON—SITE CONSTRUCTION SHALL BE 4,000 PSI AT ALL PIER INSTALLATION OPERATIONS SHALL BE SUPERVISED BY A LICENSED NEW 28 DAYS, AIR ENTRAINED FROM 4-5%. YORK STATE ENGINEER PROVIDING CONTROLLED INSPECTION. THE INSPECTOR 1 `E°�.��,°(P,.M,�) 4. COMPACTION UNDER STRUCTURES, BUILDING SLABS, STEPS, PAVEMENTS, AND SHALL KEEP A COMPLETE RECORD OF PIER INSTALLATION OPERATIONS AND A WALK WAYS SHALL BE 95 PERCENT DRY DENSITY. COMPLY WITH ASTM D 1557. PIER INSTALLATION RECORD SHALL BE FILED WITH THE APPROPRIATE BUILDING A-101TEST IN IN EACH COMPACTION LAYER, AT EACH COMPACTION SITE, OR AT LEAST IN DEPARTMENT. NO CONCRETE FOR PILE CAPS SHALL BE PLACED UNTIL PIER EACH 100 CU. YDS. OF MATERIAL VOLUME. COMPACTION UNDER LAWNS OR IN INSTALLATION RECORD IS APPROVED BY THE BUILDING DEPARTMENT. UNPAVED AREAS, SHALL BE 85 PERCENT DRY DENSITY. COMPLY WITH ASTM D THE CONTRACTOR SHALL SUBMIT AS—BUILT DRAWINGS PREPARED, SIGNED AND \ e 1557. SEALED BY A NEW YORK STATE PROFESSIONAL ENGINEER FOR ALL PIER WORK. 4'-4" 8'-5"5. lo CONTROL IZMEASURES,AIJF REQUIRECE TO DDING URINGURINGEDURING C.ONSTRUCTION SHALL BE INOSION MATERIALS CONFORMANCE WITH LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. x x x x x x x x x x x x x � x x x x r'�_ x x x x— EACH HELICAL PIER SHALL CONSIST OF 1-1/2" SQUARE GALV. STEEL SHAFT / \ \ 02X26 / \ / ANCHOR HELICAL LEAD AND EXTENSION SECTIONS AS MANUFACTURED BY CHANCE CO. AND SUPPLIED BY EXCLUSIVE DISTRIBUTOR, PREMIUM TECHNICAL X\ i 1 2 717{{i SERVICES, WESTBURY, NY. 04 F — SQUARE SHAFT WITH 3 N THE FOUNDATION LEAD SECTION CONSISTS 0 1 1/2 Q ICO N X SYMBOL HELICAL FORMED PLATES WELDED TO IT. THE SHAFT SHALL BE SOLID STEEL - ' ' 2122 ; t ; < ; _ ,-' g `' co W12X26 WITH ASTM 153 HOT DIPPED GALV. COATING. THE HELIX SIZES SHALL BE 1004 1 1/2" X 3/16" SERRATED GALV. STEEL GRATING WITH 12". W12X26 W12X26 N I , I / (...i ; —� SANDARD SADDLE CLIP FASTENERS AND METAL COATING AS MANUFACTURED BY MCNICHOLS, OR EQUAL. TYP. ALL FOUNDATION ANCHORS SHALL HAVE A MINIMUM TOTAL INSTALLATION DEPTH OF 20' BELOW GRADE AND A MINIMUM INSTALLATION TORQUE OF 4000 FT. LBS. µ_."` ) " " X I ,_- (20 TON ULTIMATE) y.`...M. .. W12X26 x c° - If N 0 ALL BOLTS SHALL BE SAE J429, GRADE 5. ALL WELDING SHALL BE DONE BY I I 0 0 CERTIFIED WELDERS IN ACCORDANCE WITH ASW D1.1. ALL MATERIAL SHALL BE x HOT DIPPED GALVANIZED IN ACCORDANCE WITH ASTM A153. A TORQUE INDICATOR I II ; BY CHANCE PTS SHALL BE USED FOR ALL INSTALLATIONS LLI I W12X26 II W12X26 II �� ! I ; ilk E t X : ! ! . f ii : : ! I . � : ' ! E ' ` # ; i # 3 ! EI I_ i X 4 w {. : # w' f'^.' E I '.{ z.'I : 4 i , { s l l t I � i I O N r STRUCTURAL DETAIL-HELICAL PILE I I EQUIPMENT PAD TRUORIENT POINT 2 ! � 2 E : i 3 E ...�, � ! f 77 �: : � # : iii � is � ,$ « E 3 A-102 f i° # I ! ! =i ( `n 1 A-101 _? ; ` ( ` I E _ � Iy _ :�. _I �" i SALE 3/411 1 0 f E. ., X I # w3w W) I x € �I € I � II : I i. i i VAM6 \ li j ! I IW1 X2 i3il E is , : 40200 MAIN ROAD X NEW GALV. STL. 16GA. DIAMOND ORIENT, NY 11957 PLATE ACROSS NEW STEEL DUNNAGE x x x x x x x x x x x hex x x x c�� x x x x - �Z— x x UNDER NEW EQUIPMENT CABINETS x TITLE: STRUCTURAL DETAILS, FOUNDATION NEW W12X26 A AFRAMING PLAN NEW W12X26 BEYOND ' \ x NEW 2-1/2"X2-1/2"X5/16" i C� ;_ '; X DATE: JULY 13, 2016 CONTINUOUS STEEL ANGLE j I PROJECT NO: 14-10823 BOLTED TO NEW W12X26 W/ 1/2" BOLTS, 18" O.C. - - ._ - - DRAWN BY: MM NEW 1 1,/2" X 3/16" CHECKED BY: TM SERRATED GALV. STEEL GRATING. SCALE: AS NOTED DRAWING NO: ' 0' 8" 1'-4" 2'-8" DUNNAGE/ GRATING DETAIL STRUCTURAL FRAMING PLAN 0- 2 4 NORTH SCALE = 1 -1/2"-1 '-0" SCALE = 3/8" = l '—O" 3/8"=1'-0" SHEET NO: 5 OF 10 STRUCTURAL STEEL NOTES 1. DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO LOCAL ORDINANCES, NEW YORK STATE BUILDING CODES, AND THE LATEST EDITIONS OF THE AISC "SPECIFICATIONS FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS," AND THE AISI SPECIFICATIONS FOR THE DESIGN OF COLD—FORMED MEMBERS. 2. STRUCTURAL STEEL SHALL CONFORM TO ASTM GRADE DESIGNATION A992, GRADE 50 (STANDARD STRUCTURAL SHAPES) OR A500, GRADE B (STRUCTURAL 17'-0" i (71 TUBING). ALL ROOF STEEL HAS BEEN DESIGNED FOR A MINIMUM TOTAL LOAD OF 50 PSF, UNLESS OTHERWISE NOTED. EQUAL EQUAL .- lo 3. ALL EXTERIOR STEEL SHALL RECEIVE ASTM A525 HOT—DIPPED GALVANIZED COATING APPLIED AT 1.25 OZ./SQ.FT. O � ;. 4. SHOP AND FIELD CONNECTIONS NOT SPECIFICALLY DETAILED ON THE DRAWINGS SHALL BE WELDED OR BOLTED. ALL BEAM TO GIRDER SHEAR CONNECTIONS SHALL BE TWO—SIDED, WEB—ANGLE CONNECTIONS PER AISC SPECIFICATIONS, LATEST EDITION. —' X X X X X X X X XX X X X —�� X X X X ^L— X X X X 5. ALL WELDING SHALL COMPLY WITH THE AMERICAN WELDING SOCIETY (AWS) STRUCTURAL WELDING CODE STANDARDS. WELDING SHALL BE PERFORMED BY ,, .. CERTIFIED WELDERS AND BE SUPERVISED AND INSPECTED BY AN APPROVED INSPECTION AGENCY AND LICENSED PROFESSIONAL ENGINEER RETAINED BY THE \ KB W6 X 15 K KB W6 X 15 KB " CONTRACTOR. SAID ENGINEER SHALL FILE ALL NECESSARY INSPECTION REPORTS AND AMENDMENTS, AS REQUIRED BY LOCAL CODES WITH COPIES TO THE ARCHITECT. ALL WELDING IS TO BE PERFORMED WITH E70XX ELECTRODES, UNLESS OTHERWISE NOTED OR REQUIRED. REMOVE ALL DIRT, GREASE, PAINT AND I I BURRS WITHIN 3 OF ALL WELDS. ALL BEAM SPLICES SHALL DEVELOP THE FULL STRENGTH OF THE MEMBERS BEING JOINED. A R � H I T E C; T S � x� 12-1 TECHNOLOGY DRIVE, SETACIKET,NY 11733 6. ALL WELDS NOT SPECIFICALLY CALLED OUT ON THE DRAWING SHALL BE THE MINIMUM WELD SIZE, AS SPECIFIED BY THE AISC MANUAL, LATEST EDITION. \ P. 631.689,8450 I F. 631.689.8459 1 wkv-w.wfcaia.con1 (SEE NOTE #14 FOR ADDITIONAL CRITERIA.) x + x 7. BOLTED CONNECTIONS SHALL BE FRICTION—TYPE USING HIGH—STRENGTH, 3/4" DIAMETER (U.O.N.), A-325 BOLTS WITH ASTM A90 GALVANIZED COATING SET '�� I I ` ! r< \ IN 13/16" DIAMETER HOLES, IN ACCORDANCE WITH THE AISC SPECIFICATIONS FOR STRUCTURAL JOINTS, LATEST EDITION. MINIMUM WEB CONNECTION(S) SHALL HAVE (2) BOLTS. 8. ALTERNATE CONNECTION DETAILS MAY x Y BE USED IF SUCH DETAILS ARE REVIEWED AND APPROVED BY THE ARCHITECT. HOWEVER, THE ARCHITECT SHALL BE ( I s : ") THE SOLE JUDGE OF ACCEPTABILITY, AND CONTRACTORS' BID SHALL ANTICIPATE THE USE OF ALL DETAILS AS SHOWN ON THE DRAWINGS. ANY APPROVED ALTERNATE DETAILS) SHALL BE INCORPORATED INTO THE WORK AT NO EXTRA COST TO VERIZON WIRELESS. ICONSULTANT: 9. CONNECTIONS SHALL BE DESIGNED FOR THE LOADS INDICATED ON THE CONTRACT DRAWINGS. WHERE MEMBER REACTIONS ARE NOT SHOWN, BEAM CONNECTIONS SHALL BE DESIGNED TO SUPPORT A VERTICAL SHEAR EQUAL TO 50% OF THE TOTAL UNIFORM LOAD CAPACITY OF THE BEAM, LATERALLY I x ( T. SUPPORTED, OR THE SHEAR CAPACITY OF THE WEB, WHICHEVER IS GREATER. co co KB KB '\KB YV6 X 15 KB 10. ANCHOR BOLTS SHALL BE PRETENSIONED TO THE MINIMUM YIELD STRESS SPECIFIED FOR STEEL CONFORMING TO ASTM A307 SPECIFICATIONS. \' 1 1 1 11 11. INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING AND/OR NON—CONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE OWNER AND THE ARCHITECT PRIOR TO REMEDIAL ACTION. ANY SUCH ACTION SHALL REQUIRE THE ARCHITECT'S APPROVAL, AND THE CONTRACTOR WILL BE x x x xt— X x x x x x x x x x x x x x �-e�-- x — x -4 FULLY RESPONSIBLE FOR ALL CORRECTIVE (MEASURES AT NO ADDITIONAL EXPENSE TO THE VERIZON WIRELESS. �c x 12. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR STRUCTURAL STEEL AND METAL DECKING IN ACCORDANCE WITH ALL PROVISIONS OF THE BUILDING KNEE BRACE ('KB'), TYP. CODE OF NEW YORK STATE FOR REVIEW BY THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. ALL SHOP DRAWINGS SHALL BE STAMPED BY A NO. DATE SUBMISSION PROFESSIONAL ENGINEER LICENSED IN NEW YORK STATE. THE CONTRACTOR SHALL CHECK ALL DIMENSIONS AND ASSUME FULL RESPONSIBILITY FOR + 3"0 GALV. STEEL COLUMN 0 7/20/16 ISSUED FOR REVIEW DIMENSIONAL CORRECTNESS AND FIT. THE ARCHITECT'S STRUCTURAL DRAWINGS ARE NOT TO BE REPRODUCED FOR USE AS SHOP DRAWINGS. CONTRACTOR \ x WITH 6"x6"x1/2" GALV. STL. 1 8/3/16 REVISED PER ATTORNEY COMMENTS SHALL REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR THE LOCATION OF MISCELLANEOUS OPENINGS AND RECESSES. k BASE AND CAP PLATES, TYP. OF (6) ON STEEL PLATFORM 2 2/21/17 ISSUED FOR FILING 13. TEMPORARY BRACING SHALL BE INTRODUCED WHEREVER NECESSARY, TO ACCOMMODATE ALL LOADS WHICH THE STRUCTURE MAY BE SUBJECTED TO DURING DASHED LINE REPRESENTS CONSTRUCTION, INCLUDING ANY EQUIPMENT AND THE OPERATIONS) OF SAME. SUCH BRACING SHALL BE DESIGNED AND INSTALLED BY THE CONTRACTOR, NEW CANOPY ABOVE SHALL BE LEFT IN PLACE AS LONG AS REQUIRED FOR SAFETY, AND THEN REMOVED UPON COMPLETION OF PERMANENT INSTALLATION(S). 14. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CHECK AND COORDINATE DIMENSIONS, CLEARANCES, ETC. WITH THE WORK OF OTHER TRADES. THE TRADE CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS, COOPERATE WITH OTHER TRADES, PROVIDE A COMPLETE JOB, AND TAKE CARE THAT GOOD WORKMANSHIP PREVAILS DURING ERECTION OF STRUCTURAL FRAME. ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE ARCHITECT. CANOPY FRAMING PLAN o� 8" 1'-4" 2'-8" 15. TOUCH—UP FOR GALVANIZED COATING SHALL BE COLD—APPLIED GALVANIZED PAINT IN ACCORDANCE WITH FS TT—P-645. 2 NORTH NO. DATE REVISION SCALE = 3/8" = V-0" 3/8"=1'-0" KEY PLAN: ALIGN AREA OF WORK LE0.w 6WW RDAD(R'NO�, NEW 22GA. 3" GALV STEEL ROOF DECK, + TYPE NS A!S MANUFACTURED BY UNITED STEEL DECK OR APPROVED EQUAL. FASTEN DECK TO STEEL WITH #12 S.S. OR GALV STEEL SELF DRILLING TEK 1-1/2" O.D. GALV. STEEL PIPE RAIL. E SCREWS ® 8" O.C. MAX 1'-6 MAX NEW GALV. STEEL W6x15 = CLOSE ENDS � ." - - 10 HANDRAIL SPLICE (AS REQ D.) 1/4"[/ L3x3x1/4" BRACING AT UNDERSIDE OF o DECK CR UKITED STATE4 LDVER`(VIFVi (M.DM I9 AVD fAfll I ..ItrVl NEW 6"x6"x1/2" GALV. STEEL PLATE °' SECURED TO NEW W605 WITH (4) GALVANIZED STEEL GRATE TREADS. 3/4"0 A325 BOLTS, TYP. NEW 3"0 GiALV. STEEL COLUMN WELDED NEW C 10x15.3 GALV. 1 1/2"0 STD TO NEW 1/12" THICK BASE PLATE STEEL STRINGER. NEW L PIPE (TYP.) 4"x4"x5/16" io NEW 5"00 x1/2" GALV. STEEL PLATE 5" HIGH GALV. NA 1/4°' SECURED TO NEW STEEL DUNNAGE WITH STEEL ANGLE. STL. TOE PL 4" (4) 3/4"0 :A325 BOLTS (TYP.) 13 x 1/4" vwwww"G 'w 01�1 If TOE BOARD Sw- FLOOR LINE SPLICE � o z O w + (2) 3/4" C� ELEVATION , , co N 1 (nP BOLTS "ORIENT POINT 2" 4O BOARD BAR A. VERTICAL SECTION A n < 1 1/2"0 STD. PIPE Li w 00 N i + 1 \ � i \ � + N 1'-0" MAX rl (2) 3/4"0 BOLTS EA. SIDE. '+ NEW W12X26 40200 MAIN ROAD 1 © ORIENT, NY 11957 1/8" 6"x2 1/2"x8" LONG 1 �rr�i�-rrq Q op 1/2" BENT NP 1/4.. � 5" � � ^ 1 100 TITLE: — 111/41' I wcl , ® ® NEW 3 0 GALV. STEEL (2) 3/4" N CANOPY FRAMING PLAN ---------- -------- 0 1 /411 COLUMN WELDED TO NEW BOLTS, TYP. AND CANOPY DETAILS -------- 1/2" THICK BASE PLATE G 3„ O NEW 5"x10"x1/2" GALV. �A NEW C1Ox15.3 �_V'0 CONNECTING PIPE STEEL PLATE SECURED DATE: JULY 13, 2016 TO NEW STEEL DUNNAGE GRADE L 3" X 3" X 5/16" Oo WITH (4) 3/4"0 A325 PROJECT NO: 14-10823 RAILING SPLICE CORNER DETAIL SECTION X GALV. STL. ANGLE II 1 BOLTS (TYP.) / DRAWN BY: MM (1) 3/4"0 A325 BOLT. CHECKED BY: TM TYP. I� CLOSE ENDS SCALE: AS NOTED 3/8" TAB WELDED TO POSIT/BEAM DRAWING NO: B. TYP. KNEE BRACE C. PLAN AT CANOPY POST 'C' TYP. RAILING DETAILS- CANOPY POST / FRAMING DETAILS STAIR DETAIL tAm I (D2e00_ SCALE 1 1 _ —1 01/2"=3 SCALE = 1 4 SCALE _ 1/2"= 0 SHEET NO: b OF 10 — 1��IPWFV 11 ISM 11 ANTENNA PLUMBING DIAGRAM ANTENNA SPECIFICATIONS ANTENNA NOTES MANUFACTURER: RAYCAP MODEL NUMBER: RxxDC-3315-PF-48 z;. WEIGHT: 32.0 LBS (TOTAL) 15.73" 10.25" ,ANTENNA MANUFACTURER: AMPHENOL lo ' ANTENNA NOTES: 4-Lines I -Antenna IMODEL NO.: CWWX063X25G00 Electrical/ 4-D a 'r 2-QuF e 15.73" Antenna Variable N echanical Antenna Antenna Model Qu nti Azimuth Downtilt Downtilt Weight Cables 12.07�� ty _ 0 � � 000Lo 850 - Cellular N/A 7001850-PC S AW S a; O N 000 f ° nj PCS _ EVDO N/A r Alpha 700 - LTE CWWX063X25G00 1 60 6 0 41 (4) 7/8" h`` r/ N Fnl AWS - LTE SAME AS LTE 3 0 ' PCS - LTE SAME AS LTE 0 0 ''• 850 - Cellular N/A x A • BOTTOM VIEW .A.. R C H I T E C T S PCS - EVDO N/A •• '1 �• ' ti S.,• FRONT VIEW SIDE VIEW 12-1 TECHNOLOGY T�P,1VE,SETAUKET, NY 11733 Beta 700 - LTE CWWX063X25000 1 240 2 0 41 (4) 7/8" �6+ ;.< �,at4 °f4ti ° P. 631.689.8450 1 F. 631.689.8459 1 AAk-w.wfcaiaxom AWS - LTE SAME AS LTE 0 0 PCS - LTE SAME AS LTE 0 0yo "" ' . 850 - Cellular N/A = PCS - EVDO N/A Gamma 700 - LTE CWWX063X25G00 1 350 6 0 41 (4) 7/8 1 i� FRONT p t' AWS - LTE SAME AS LTE 3 0 1 0, 00 REAR j + PCS - LTE SAME AS LTE 0 0 I O NOTES: 1. ALL INDICATIONS OF NORTH ARE FOR REFERENCE ONLY. CONTRACTOR TO VERIFY IN IELD TRUE NORTH PRIOR TO I000 SECTOR ANTENNA INSTALLATION. 7A,G86P,A 7 AC8GP, , 1 oONsu�rA 2. PROVIDE DOWNTILT AND MOUNTING BRACKETS FOR MOUNTING UP TO A 3-1/2" O.D GALV. STEEL PIPE. THE I MNG OUNTING O Q MODEL NUMBERS FOR THERESPECTIVE ANTENNAS EMPLOYED ON THIS PROJECT ARE # KS09TO1. I o 3. INSTALL GPS UNITS ASINDICATED. ANTENNA MOUNTING HARDWARE AS RECOMMEN ED BY MANUF. VERIFY EXACT 1 1 MOUNTING LOCATIONS WITH VERIZON WIRELESS RF ENGINEER. • • • - -- «- - - , 1 . 4. ADHERE TO MANUFACTURES MINIMUM BEINDING RAD US AND RECOMMENDATIONS �OR ANTENNA CABLE I 12.0" INSTALLATION (TYPICAL FOR ALL ANTENNA CABLES). IMAIN DISTRIBUTION BOX DETAILS - r.:€�act�,►.:�$ uta��es�._:�r •_. €�t'' • n 5. PATCH, REPAIR AND RE TORE ANY AREA WHICH IS AFFECTED BY INSTALLATION OF A Y ITEMS WITHIN THE SCOPE 7 0$ �A, 7AC88PA PA ��A 1 = L OF WORK WITH NEW MATERIALS TO MATCH, ALIGN AND BE CONTIGUOUS WITH EXISTI G SURROUNDING SURFACES. 1 SCALE 6. ALL CABLE LENGTHS MUST BE V.I.F. TAG BOTH ENDS O ALL TRANSMISSION LINES WITH BRASS TAGS DENOTING __. ;VNµ µµ ay„ I NO. DATE SUBMISSION 1 FRONT VIEW SIDE VIEW TOP VIEW CROSSBAND COUPLER MANUFACTURER: RFS GALV. STEEL COLOR CODE AND SECTO MODEL: FD9R6004 1 C-3L MOUNTING 0 7/20/16 ISSUED FOR REVIEW 7. ALL EXISTING CABLES TO REMAIN. -, _.,. ..... ..,. ._._.... ._.__ ......._ I 1 .5 PIPE 1 8/3/16 REVISED PER ATTORNEY COMMENTS 8. CABLE DIAMETER t�s�E.:. A,«�,� � I GPS MANUFACTURER: PCTEL 6.J x _ MODEL NO.: GPS-TMG-HR-26N 2 2/21/17 ISSUED FOR FILING SECTORS - 7/8" DIA. CABLE UP TO 100' 7C RRH .. "' WEIGHT: 0.6 LBS / ( ) sir Fulr.�re �° 3.2" (2) GALV. SECTORS - 11/4" DIA. CABLE (UP TO 200') .63 LBS/FT. MOB ---""` � 6.5 STEEL PIPE SECTORS - 15/8" DIA. CABLE (201' OR GREATER) .70 LBS FT. �Lo CLAMPS 10 RPS Lo r IM9= FRAME � L-0 [.�­­ NEW DIPLEXER SECTOR SECTOR 850 LTE-C LTE-A PCS AWS GPS SECURED TO ALPHA WHITE GRAY RED ORANGE PURPLE YELLOW BROWN ° ° GALV. STEEL FRONT VIEW SIDE VIEW TOP VIE V'J MOUNTING BETA BLUE GRAY RED ORANGE PURPLE YELLOW PIPE NO. DATE REVISION ANTENNA DETAILS GAMMA GREEN GRAY RED ORANGE PURPLE YELLOW DIPLEXER DETAILS 1 � KEY PLAN: SCALE = 3/4 = 1 '-0" GPS UNIT SCALE = 1 = 1 '-0" AREA OF WORK 2'-4 1/2" 2'-4 1/2"� 2'-5 1/2"_+ xn,ovcm msrer,,.aec°wxev°x S MANUFACTURER: ALU REMOTE RADIO HEAD (RRH) MANUFACTURER: ALU REMOTE RADIO HEAD (RRH) MANUFACTURER: ALU REMOTE RADIO HEAD (RRH) � - MODEL NUMBER: B13 RRH4x30 (700 ILTE/850) MODEL NUMBER: B25 RRH4x30 (PCS) MODEL NUMBER: B66A RRH4x45 (AWS) BAS -_x WEIGHT: 55.6 LBS WEIGHT: 53.0 LBS WEIGHT: 56.8 LBSLo �,. I .++•' , .A,, P-MI,, srrescov,xram_vr 11.7" 7.2» •�`•� zz c iv _ ..��,9„m,.°u„v am .w; = =: zt� _t 11.8” 75 ...- 12.0 72 o°o FRONT PLAN VIEW `n 0000_ . . _ MOUNTING == «. e o 0 0 BRACKET - _ ALCATEL LUCENT EZ BFo STACKABLE \-MOUNTING �: oogo 0 o \.-MOUNTING �” o0 0p0O o o BATTERY CABINETS SPECIFICATIONS: EE. 00h . oma' ` ' oo_o_o ° 05` BRACKET ori 000e e � �. W o� 0000 e BRACKET _ N e N °ooe e � -- •= ": = o o -F :== � .-� w .- WEIGHT: WITHOUT BATTERIES - 636 LBS o o e o o ;,.:'„� g §. e e o 0 o e w , ."_ z: ';i c� o N e o o - , o o :�µ-- = ”' FULLY EQUIPPED - 2628 LBS 0000 ' 0000 ' I � 0000 � oo # OF SHELVES: 6 e o o OOOODOOIDOOODOOOROODDE � � w �� x o o o o 0 0 0 0 0 o OOOOOOOODDOOOOOOODDODODOO � � �; o °o°e o OODOODOOOD000000000000000 o o o o e .�� � ; o o °o o e o e o 0 0 o BATTERY (Ah): 100 (Ah) iv o e �v .• �., FRONT SIDE e o o � o I000DDDooDODD0000DDDDDDDD DD000 O oo°e D _ — ... .� OD OO D D OO�D000 0 ID DD000DD ���� FY I �ooOD00000 o _ �� - e D D D Ooo ���� e e e e °.���. .� OOOOOODOODDDODDDO DD DDD DD 0 e o o e o ;-..,,.•�. -.,, r PER BATTERY WEIGHT: 83 LBS. . o o o o e ( o o o o o e r o e . w. �. °000 o � «�[ oo°e o o . o .,, �.•.: ELEV • as Doo _ o 0 0 0 ou , o o , o ol00DDDDOODDOD000O0DDDDDOODoIo --.• ZZ VIEW D000000@OOOODODDOOOODOD000 ~ , . o IoDDDDODC000O0D000DDOD000O0 - �� $, , '11.8" � a CAPACITY: 1200 (Ah) ' 12.0" 11.7" COOLING: FAN COOLED '' FRONT VIEW SIDE VIEW TOP VIEW ISOMETRIC RENDERING FRONT VIEW SIDE VIEW TOP VIEW ISOMETRIC RENDERING FRONT VIEW SIDE VIEW TOP VIEW ISOMETRIC RENDERING 2'-2- 2•_6- 2'-2- "ORIENT POINT 2" ° ° •- ° ° EXISTING PIPE MAST EXISTING PIPE MAST Q EXISTING PIPE MAST NEW SMALL PIPE MOUNT o NEW SMALL PIPE MOUNT e o NEW SIMALL PIPE MOUNT KIT 40200 MAIN ROAD KIT FROM MANUFACTURER o o KIT FROM MANUFACTURER o o FROM (MANUFACTURER ° ° ORIENT, NY 11957 o (ACCEP'TS 2"0-6"0 PIPE) (ACCEPTS 2"0-6"0 PIPE) o o (ACCEPTS 2"0-6"0 PIPE) o e 00 00 *DoPLAN VIEW / <::<` '� ° ° ;" TITLE: NEW RfRH WITH SOLAR SHIELD �� ANTENNA INFORMATION AND NEW RRH WITH SOLAR e NEW RRH WITH SOLAR o EQUIPMENT DETAILS a o SHIELD TO BE SECURED o SHIELD TO BE SECURED - o TO BE SECURED TO NEW GALV. ii -xg° TO NEW GALV. 2-7/8"0 o e TO NEW GALV. 2-7/8"0 0 2-7/8"'� STEEL MOUNTING PIPE - STEEL MOUNTING PIPE STEEL MOUNTING PIPE o o WITH MANUFACTURER'S WITH MANUFACTURER'S WITH MANUFACTURER'S e�' HARDWARE HARDWARE HARDWARE OUTDOOR CABINETS NEW JULY 13, 2016 DATE: ALCATEL-LUCENT LIGHTRADIO CABINET PROJECT NO: 14-10823 9712 OUTDOOR CABINET 180KG DRAWN BY: MM FRONT ELEV SIDE ELEV REAR ELEV CHECKED BY: TM SCALE: AS NOTED DRAWING NO: RRH DETAILS_ EQUIPMENT CABINET DETAILS000 4 SCALE = 1 " = 1 '-0" SCALE = 1/2"=1 '-0" SHEET NO: 7 OF 10 TOP OF CANOPY . V.I.F. 89'-O"± AGL T.O. NEW CONCEALMENT POLE EXTENSION y 88'-6"f AGL T.O. NEW VERIZON WIRELESS ANTENNAS :r✓", CANOPY POST, TYP. ' EXTEND TWO (2) 27.88" 3" EMT CONDUITS 10'3" ° ° ° FROM TOP OF TROUGH AND (3) NEW RAYCAP MAIN DISTRIBUTION TERMINATE AT NEW 1 1/2"0 STD PIPE ° 0 EQUIPMENT CANOPY CEILING HANDRAIL WITH 4"X1/4" STEEL EXISTING REMOVABLE COVER FOR ANTENNAS n ,. BOXES MOUNTED TCABLE MOUNTING TOE PLATE MOUNTED TO NEW W PLATFORM HANDRAIL CONTRACTOR VERIZON WIRELESS EQUIPMENT PLATFORM— PROVIDED AND = INSTALLED (NEMA 1) 10"x10"x18" to I LO TROUGH A R C H I T E C T S 12-1 TECHNOLOGY DRIVE,SETAUKET,NY 11733 EXTEND THREE (3) P. 631,689.8450 1 F. 631.689.8459 1 -vtiu14.u-fcaia.coni 3" EMT CONDUITS ° FROM TOP OF Ll TROUGH AND SIDE ELEV TERMINATE AT BOTTOM OF UPPER TROUGHDC GENERATOR DISCONNECT ` l PROVIDE TWO (2) CABINET 84'-6"± AGL °� 2-1 2" GRS MFR: SQUARED 6 MIN 6 MIN / CATALOG N0. HU365R OF NEW VERIZON WIRELESS ANTENNAS 3811 O O O NIPPLES AND (YA MYERS HUBS WT. 187LBS. lo BETWEEN THE 600V / 400A / 3—POLE UNISTRUT CAP (TYP) RAYCAP BOX AND 27,88 � - ° ° THE TOP OF THE UL LISTED CONSULTANT: EXTERIOR TROUGH. ENCLOSURE RATING NEMA 3R 00 00 0 Lr) Nd- CONTRACTOR O PROVIDED AND I LTr- H H --i H -1 1--1 H INSTALLED WEATHERPROOF (NEMA 3R) I 10"X10"X6'-0" TROUGH MOUNTED - TYP. ELEVATION ON UNISTRUT L PLAN VIEW (3) NEW VERIZON WIRELESS ANTENNAS AND MOUNTING BRACKETS, TYP. SEE DETAIL NO. DATE SUBMISSION 1/A-103.00 GENERATOR DC DISCONEC DETAIL 0 7/20/16 ISSUED FOR REVIEW MAIN DISTRIBUTION BOX MOUNTING DETAIL T Q 1 8/3/16 REVISED PER ATTORNEY COMMENTS 2 0 2 2/21/17 ISSUED FOR FILING 1 SCALE = 3/4"=1 '-0" SCALE = 1 " = 1 '-0" w J W Z O N bi BUILLEM121413 r AB EXISTING CONCEALMENT POLE WITH NEW 20'-0" 1 > EXTENSION o 3 N W NEW TELCO/ POWER CABINETS Pr°!pact: Type: .,.,. z MOUNTED TO NEW STEEL HAND o RAIL WITH P1000 UNISTRUT LL NO. DATE REVISION Prepared EIV, Data: Z o KEY PLAN: z AREA OF WORK LLI X X s wt; •'�'" ,, w ceawemcn noA°cwrrs°sn Driver Info LED info � Type: ciorxstantcurrerrt w ita° 24W (6) NEW DIPLEXERS TO BE INSTALLED WITHIN w - — — — I Z 1210V: 0.:M Color Tamp. 4=X(Nlwtml) NEW CONCEALMENT POLE EXTENSION. ANLL > Nr,or°rsu 6TA1L eAUKtO¢f 59 Op 2mv: MIA Wor cy: 84Cni DETAIL 3/A-103.00 �rM1,..ArSTAt.rA 24r71P' NUA L70 Lifespan: 110DOM E 2T IJe NdA Lumens,. 1,684Id Ls Irk Wafts: 2f6W F_rticacy: 64 LPW z Two adjustable 12W LED floodights.Equirvalent its WSW ER3 1haloganfAde floods. - Mkirwiernatle diffusion lens �Nzos light output without glara. Cobr.Flmk WA L 6.3 ft �— rvle UrItU SfATYS f.°St:xM151rY1' NEW 1 1/2"0 STD PIPE mins su.m recwrrenorcarn HANDRAIL WITH 4"X1/4" Technical Specifications ' STEEL TOE PLATE MOUNTED 2'-0" TO NEW VERIZON WIRELESS 10Llsting4� M ",,..0 Electric$! i5 � w-"ry tCaask�ts: I EQUIPMENT PLATFORM IJLL.isting: IDrider: lHigh4amperalLuesili€oneggske'-s (12) NEW 7/8"0 VERIZON WIRELESS ANTENNA tabt a for wet locations. Innovative Integrated driver th with 120V IFInlsh: CABLES TO BE ROUTED UP CONCEALMENT POLE I IESNA LM-79&LM-80 Tinting: "tRIAC onstrrd ELVilori (Our eft*onrnsntallyfr tdh polytaterpow r tings FROM NEW EQUIPMENT PLATFORM TO NEW ' 'C'Q i tarefformulatadforh urabill andla testi ANTENNAS I F£A9 LED ktrntn have rt tested by an __ __..___ng ._. _ _ _ free,and S is � Irxd trit atony in accordance with IESNA LM- Thmrmal Management: ,and eaontialn no VOC or toxic Meavy mejafs. � 79 and and have,been received the Superior heat sinkkQ with externat Air-Ftow term (Green Tochnology: D,q:m mom of Energy'Ligh.itlg Fsels"Abel, I LED Ch arsrCttzkistics Mous ingt IfiAercury ar�d Lf lr frxge,and RorfS uampilart#.Pnfyostar r cost firth rormulsted t rhe use of Vt�C > LEDs: plate chart n housing,!arts fterrra a 111 fnllrig for loxie hravy rnetols. plate I>ElcdtkhIp,hW"utput,long-life LECts (OtheCa g M1>Mw A I Reflector: > Lifespan: Saran-sperxdar,vacuurn tallzed polycarbonate California Title 24. 100,000-Hmr LED lifespan,based on IES LM-80 [BULLET2x12 c�ornpiles W h 2013 Caflfc<mla Title 24 I rest b and TU-21 caica.rlatioo Lyras: tbuiIding and ealixtrical cmd6s as,d residential outd" Mlrxo dsma^fc diff aslon for smooth and even fight ffghtlV fixture vAth no additional hardware required Color Stability- dot on mn d as a commercial aufdoar nan»pole4ro rated fixture LED color tamnpora#urm Is vramantled to shaft no more 1A#unti 9 M W'a'rts when us6d with a photosartnu tr ntrol. Bf�C t2InM7ravet'a5year parlocl- Select catalog numberto ondor:aphotosensar. 10.75"� ' "ORIENT POINT 2" Color Uniform Ity. y-uty mounting arm wit.•C7'Ong seat and iWarranty': ° ° ° ° ° ° ° steel screws ° ° ° RFC's range d CCT(Correlated Color Tarnperaturs) FRA.B warrants that our LED prvducts vlrll be firm from > fcAle s tha guldoNnas of the A r%National defects N inatarlals and wodm,anship for a parlors of Standwd for Sp arms for tfia Chromeficity of frrve(5)years 5 orrt the ct sis of cfiellvery to I reser, ° StIk1 Sta!a Ugh"(SSL)Produels,ANSI 078.377- Uncluding mveraga of 16ht exitput,e0or gtaNllty,dtmr 2011, performance and fixture finish. I`eafurs5 40200 MAIN ROAD Dimartsi�hrt� ' I ORIENT, NY 11957 4 1/2" Twoal,ustabkc 125^x'LED ltoodlghis F' 368 1T1m Equlvalemto2x75VV BR31'fza€cgerWde floods 4 1/2" f+.Iiurpnsma*,ic:diffusion ler s opsrnl-ms,I girt output williout glare T17LE: NEW GALV. STEEL GRATING 114 mm--4 > 10O. k-hour ILLDL;ruspan DETAILS 6x 352 mmC9!5 ' DATE: JULY 13, 2016 j 69'-0"f AGL PROJECT NO: 14-10823 "I- T.O. EXISTING CONCEALMENT POLE 0 0 0 DRAWN BY: MM � �3�4°---4 171 mm CHECKED BY: TM SCALE: AS NOTED DRAWING NO: TELCO/ POWER PANEL RACK DETAIL LIGHTING SPECIFICATION ANTENNA MOUNTING DETAIL 3 — " _ '— " SCALE = N.T.S. SCALE = 1 "=1 '— "4 5 SHEET NO: 8 OF 10 SCALE — 1 1 0 0 VERIZON WIRELESS EQUIPMENT COMPOUND ON STEEL DUNNAGE. E7 NOTE H—FRAME §' (EXISTING) NOTE: .. 1. CONTRACTOR SHALL ENGAGE THE SERVICES OF 1200 200 NEW METER (SEE AN UNDERGROUND UTILITY LOCATING COMPANY TO b NOTE E2). LOCATE ALL UNDERGROUND EQUIPMENT IN THE `f TRENCHING AREA TO AVOID ANY DAMAGE. NOTE . EXISTING METER EQUIPMENT NEW COMBINATION 6" MATCH EXISTING GRADE METER MAIN ENCLOSURE 2. HAND EXCAVATE WITHIN 5' OF EXISTING CONDITION(SEE NOTE Ell). : ; " UNDERGROUND UTILITIES (V.I.F.) MAINTAIN 18" MIN. ",. CLEARANCE, OR AS DIRECTED BY THE VORC. BACKFILL AT TRENCH SHALL O H—FRAME CONTRACTOR TO MAKE ALL PVC JOINTS WATERTIGHT. BE COMPACTED IN 12" A R C H I T E C T S OM T& VW TEST PRIOR TO BACKFILLING. (NEW) LIFTS TO 95% DRY DENSITY 12-I TECHNOLOGY DRIVE, SETAtIhET,NY 11733 NOTE E6 COMPACTED SUBGRADE P. 631.689.8450 ( F. 631.689.8459 1 uwwm caiaxom (COMPACT IN 8" LIFTS TO 85% DRY DENSITY NOTE 6" WIDE METAL CORE E3 EXISTING UNDERGROUND WARNING NOTE TAPE PRINTED WITH E5 PSEG E R 1—PHASE CAUTION BURIED UTILITY TRANSFORMER _ / LINES" EXTERIOR GRADE / 2x12 MOISTURE TREATED -' WOOD PLANKS PAINTED .:: RED. NUMBER OF PLANKS AS REQ'D FOR WIDTH OF CONSULTANT: TRENCH ELECTRICAL NOTES A / /%/\ /% ti / \\/\ \/\\/\\ \ y1 / WASHED SAND IN 6" LIFTS E1 PROVIDE NEW UTILITY APPROVED, SINGLE PHASE, 200A, OUTDOOR COMBINATION METER PAN/MAIN \///\// ////////j//// �,�/ / _ PVC CONDUIT, TYP. CIRCUIT BREAKER (SIEMENS MM0202L1200RLC) LABELED 'VERIZON WIRELESS . //\\/\\j / / COORDINATE TYPE, SIZE E2 COORDINATE WITH PSEG TO SET ,A 200 AMP, SINGLE PHASE METER IN ACCORDANCE WITH _ �p1`Z / _ __=I AND NUMBER OF CONDUITS PSEG'S STANDARDS. LABEL METER "VERIZON WIRELESS". CONDUIT/WIRE LEGEND I= / p�`� _—III—_—II UNHELECTRICAL IO DRAWINGS _ _ � / / _—I�I—III _—I I E3 GROUND THE SERVICE DISCONNECT PER ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE. —I I=) — I I—� I—I I AND WITH ELECTRIC AND A PRIMARY AND SECONDARY CONDUIT/CABLE SHALL BE LOCATED AND PROTECTED c° III—III _—I I—I III—III=III TELEPHONE UTILITY PROVIDE A #6 AWG SOLID COPPER GROUND WIRE AND 3/4" X 10' GROUND RODS (2 O I=I I=I .:., I=III=I I =I I=III=�I i=I I COMPANIES REQUIRED). GROUND WIRE SHALL BE RUN IN 3/4 SCH 80 PVC CONDUIT WHERE EXPOSED TO DURING CONSTRUCTION. PHYSICAL DAMAGE. MAXIMUM RESIISTANCE TO GROUND SHALL BE 5 OHMS. PROVIDE AND INSTALL B 2-1/2" SCHEDULE 80 PVC CONDUIT WITH 3—#4/0 BETWEEN THE TRANJSFORMER I—III—III —III—III— —III—III=III=III=III— UNDISTURBED EARTH ADDITIONAL GROUND RODS NOT LESS THAN 6 FT APART TO MEET MINIMUM GROUND RESISTANCE I I=) I =1 I I=I I 1-11 E9 I I=I I I=I I I=III NO. DATE SUBMISSION AND THE NEW SERVICE DISCONNECT. AS REQUIRED. I— E4 INTEGRATED SERVICE PANEL (ISP) FURNISHED BY VERIZON WIRELESS AND INSTALLED BY THE C 2-1/2" SCHEDULE 80 PVC CONDUIT WITH 3—#4/0 + 1 — #2 GROUND I —III—I —I I—� I I—I I=I I —_ 0 7/20/16 ISSUED FOR REVIEW THE ISP SHALL CONTAIN 200 AMPERE UTILITY AND EMERGENCY CIRCUIT O I `:` I I=I I I I=I I=I I I 1 8/3/16 REVISED PER ATTORNEY COMMENTS CONTRACTOR. BETWEEN THE NEW SERVICE DISCONNECT AND MAIN CIRCUIT BREAKER IN THE I I I I—I I —I�I—I�I—I�I—I BREAKERS, MANUAL TRANSFER SWITCH, AND 42 POLE PANELBOARD ALL HOUSED IN A NEMA 3R INTEGRATED SERVICE PANEL. I—i I I I I I= _ 2 2/21/17 ISSUED FOR FILING = ENCLOSURE. ISP SHALL BE UL LISTED AND SHALL HAVE A "SUITABLE FOR USE AS SERVICE I I EQUIPMENT" LABEL. MINIMUM INTERRUPTING CAPACITY SHALL BE 22,000 AMPERES FULLY RATED. II I=I —I I (— CONTRACTOR SHALL COORDINATE WITH PSEG TO DETERMINE THE ACTUAL AVAILABLE FAULT 4" 4' CURRENT AT THE POINT OF CONNECTION AND NOTIFY THE ENGINEER IF THE SPECIFIED 22,000 AIC IS NOT ADEQUATE. E5 GROUND THE INTEGRATED SERVICE PANEL PER ARTICLE 250.32 OF THE NATIONAL ELECTRICAL ELECTRICAL INSPECTION CODE. PROVIDE A #6 AWG SOLID COPPER GROUND WIRE AND 3/4" X 10' GROUND RODS (2 REQUIRED). GROUND WIRE SHALL BE RUN IN 3/4" SCH 80 PVC CONDUIT WHERE EXPOSED TO PHYSICAL DAMAGE. MAXIMUM RESISTANCE TO GROUND SHALL BE 5 OHMS. PROVIDE AND INSTALL ADDITIONAL GROUND RODS NOT LESS THAN 6 FT APART TO MEET MINIMUM GROUND RESISTANCE THE ELECTRICAL CONTRACTOR SHALL PROVIDE A CERTIFICATE OF AS REQUIRED. CONTRACTOR SHALL TERMINATE THE GROUNDING ELECTRODE AT THE GROUND BUS ELECTRICAL INSPECTION FOR THE WORK FROM AN APPROVED WITHIN THE ISP AND ENSURE THAT THE SYSTEM BONDING JUMPER HAS BEEN REMOVED. ELECTRICAL INSPECTION AGENCY AND PAY ALL ASSOCIATED FEES. NO. DATE REVISION E6 1OKW DC DIESEL ENGINE DRIVEN GENERATOR WITH WEATHERPROOF HOUSING INSTALLED ON DUNNAGE. GENERATOR SHALL BE FURNISHED AND INSTALLED BY VERIZON WIRELESS. KEY PLAN: AREA OF WORK E7 PORTABLE A/C GENERATOR RECEPTACLE FURNISHED WITH ISP. COORDINATE FINAL LOCATION WITH VERIZON WIRELESS REPRESENTATIVE PRIOR TO INSTALLATION. CEOAA emcx sono ryvr Ao sol f.181.AIiA B}ATR PAAKCOMM1961p1 111AIY.M W.+CN 6 ELECTRIC RISER DIAGRAM UTILITY TRENCH E } 1 3 SCALE = N.T.S. SCALE = 3/4"=1 '-0" NN C}IED 6}A}Efi CO.'ER`MCK} M.Ann,ACII.m PAOPPATV LINE OF MINIMUM CLEARANCES----,,, ENGINE EXHAUST POLAR POWER GENERATOR f Ld o 13 MODEL#: 82201-3CA1 Q f SERVICE I LL] rlon o 7-/ (a nk' f I ACCESS cnHOT AIR EXHAUST POWER 10KW FRONT ® FOUR SIDES FUEL TYPE: DIESEL cN �' GUARDED OUTPUT DC VOLTAGE: 24-500 f _ $ EMERGENCY STOP REMOVABLE DOOR "ORIENT POINT 2" ISUZIJ ENGINE: 3CA1 - - � SWITCH �- � SERVICE ACCESS CYLI[� DER VOLUME: .9 LITER O opo 00 � WEIGHT DRY 1106 lbs ELECTRICAL � GUARDED 00 ) 00 r- LOCKING HANDLE COOLANT CAPACITY: 1 .8 LITER 6 PENETRATION 18 MIN 0 I L CAPACITY 2 .8 LITER I`! AREA i SERVICE � 40200 MAIN ROAD i AccEssC 0 L D AIR INLET, ORIENT, NY 11957 OPERATING TEMPERATURE: —40°C TO 72°C FRONT DOOR. FIXED DOOR FUEL CONSUMPTION APPRX. : 250 /kWhr ( ) 9 � 33.25 � FRONT DOOR IS NOISE LEVEL: 66dB @ 7m � MAIN ACCESS TITTLE: COLD AIR INLET RISER DIAGRAM, GENERATOR INFORMATION AND FIXED REAR D 0 0 R TRENCHING DETAILS GENSET UL2200 LISTED 2.1 `n ° ° ° oil ETL LISTED PER UL2200 BY INTERTEK TESTING Q3211 29.62 29.62 DATE: JULY 13, 2016 49.39 PROJECT NO: 14-10823 LAB S 56.2 DRAWN BY: MM CHECKED BY: TM BOTTOM VIEW TOP VIEW FRONT VIEW SIDE VIEW SCALE: AS NOTED DRAWING NO: GENERATOR INF00000 tORMATION m 2 „ , SCALE = 3/4"=V-0"-0„ SHEET NO: 9 OF 10 7777`777, NOTE: THIS DETAIL DEPICTS GENERAL GROUNDING GROUNDING KEY NOTES METHODOLOGY FOR TYP. ANTENNA INSTALLATIONS, SEE ARCHITECTURAL DRAWINGS MASTER GROUND BAR (MGB) — GALVANIZED STEEL GROUND BAR BY ELECTRIC MOTION FOR SPECIFIC ANTENNA MOUNTING GPS UNIT AND OA COMPANY WITH INSULATORS MOUNT, TYPICAL FOR (4) AT CANOPY , 0 #2/0 AWG GREEN INSULATED SOLID OR STRANDED COPPER WIRE FROM MASTER GROUND s ° BAR TO EXTERIOR GROUND RING (EGR). ` i ft D TYP. p TYP. #2 AWG GREEN INSULATED SOLID OR STRANDED COPPER WIRE EQUIPMENT GROUND BUSS O TO (MGB), ALONG EQUIPMENT LINE AS INDICATED. B. W NEW WEATHER CANOPY D #6 AWG GREEN INSULATED STRANDED COPPER WIRE FROM EQUIPMENT TO EQUIPMENT ABOVE NEW VERIZON O GROUND BUSS. '"°" -" WIRELESS EQUIPMENT K O o PAD #2 AWG SOLID TINNED COPPER WIRE EXTERIOR GROUND RING (EGR) BURIED 42 BELOW _= GRADE, CONNECTED TO GROUND RODS THAT ARE INCORPORATED INTO THE EXTERIOR TYP OE GROUND RING. ALL CONNECTIONS ARE TO BE CAD WELDED AND SPRAYED WITH COLD—GALVANIZED PAINT. A R.. C H I T E C T S NEW YO CANOPY 0 #2 AWG SOLID TINNED COPPER WIRE FROM UNISTRUT FRAME (ELEC/TELCO RACK) TO EGR. 1'.24 TECHNOLOGY DRIVE, SETAUKET,NY 11733 • POST O CONCEALMENT POLE GROUND BAR (TGB) P. 631.689,8450 1 F. 631.689.8459 I -ww%v.wfcaia.c«m • GPS COAXIAL CABLE TO OH #2 AWG SOLID TINNED COPPER WIRE FROM ICE BRIDGE TO MGB — —� COMMUNICATION EQUIPMENT 10 #2 AWG SOLID TINNED COPPER WIRE FROM CANOPY CONDUIT SUPPORT TO MGB. ' • "' .�; O SECTOR ANTENNA GROUND BAR. (SAGB) ONE BAR PER SECTOR. I I ; � ATT CANOPY , i e N ONLY) OK COAXIAL GROUND KIT (CGK) DO NOT INSTALL ON BENDS. #2 AWG SOLID TINNED COPPER WIRE FROM EACH ANTENNA MOUNT TO SAGB. CAD—WELD f o o I I K o :. TYP TO MOUNT, TYP. =° ii 1 M #6 AWG STRANDED GREEN THWN INSULATED COPPER WIRE FROM EACH CGK TO SECTOR CONSULTANT:" 1/2"0 COAXIAL O ANTENNA GROUND BAR (SAGB). �� � JUMPERS ii ,� TYP L;__ I ON #2 AWG SOLID TINNED COPPER WIRE FROM EACH GPS CGK TO SAGB. I I L • I •%� ' I TYP 0 2 AWG SOLID TINNED COPPER WIRE FROM REMOTE SECTOR ANTENNA GROUND BAR ' — O SAGB) ROUTED TO CONCEALMENT POLE GROUND BAR (TYPICAL OF 3). II I J •• 5/8" X 10'-0" LONG COPPER CLAD STEEL VERTICAL GROUND ROD BURIED 42" BELOW FIN GRADE. ADJACENT GROUND SHALL RODS PLACED NOT MORE THAN 15' & NOT LESS THAN 6' APART FROM — Q 5 8" X 10'-0" LONG COPPER CLAD STEEL VERTICAL GROUND ROD IN INSPECTION TEST O ELL BURIED 42" BELOW FIN GRADE, TYP. OF (2). (SEE DETAIL 3, THIS SHEET) L • • —� • —1 • — -�— • • —� • • � • • �• J S # 6 AWG STRANDED GREEN THWN INSULATED COPPER WIRE FROM COAXIAL GROUND KITS (CGK) AT BASE OF CONCEALMENT POLE TO TGB. (TYP FOR EACH CABLE.) NO. DATE SUBMISSION GROUND 0 7/20/16 ISSUED FOR REVIEW GROUND BARD TO MASTER OT # 2 AWG SOLID TINNED COPPER WIRE FROM NEW TGB AT CANOPY CONDUIT SUPPORT TO 1 8/0/6 REVISED PER ATTORNEY COMMENTS NOTE: CONCEALMENT POLE GROUND RING. 2 2/21/17 ISSUED FOR FILING EXCAVATE BY HAND FOR THE CONNECTIONS TO A I THE EXISTING TOWER GROUND RING TO ENSURE OU # 2/0 AWG SOLID TINNED COPPER WIRE FROM CONCEALMENT POLE GROUND LUGS TO THAT SAID GROUND RING AND GROUND LEADS OF CONCEALMENT POLE GROUND RING (TGR). (TYP OF 2) OTHER CARRIERS ARE NOT DAMAGED B O # 2/0 AWG SOLID TINNED COPPER WIRE CONCEALMENT POLE GROUND RING (TGR) BURIED 42" MIN. BELOW GRADE, CONNECTED TO GROUND RODS THAT ARE INCORPORATED INTO TGR. ALL F CONNECTIONS ARE TO BE CAD WELDED AND SPRAYED WITH COLD—GALVANIZED PAINT. (EXISTING) ® GROUNDING SYSTEM CONNECTIONS O # 2 AWG SOLID TINNED COPPER WIRE FROM GENERATOR ENCLOSURE TO GROUND RING Q COPPER GROUND RODS O # 6 AWG STRANDED GREEN THWN INSULATED COPPER WIRE JUMPERS CONNECTED 0' 8" 1'-4" 2'-8" FROM ICE BRIDGE SECTIONS TO ICE BRIDGE POSTS. (CAD WELD ALL CONNECTIONS) GROUNDING SCHEMATIC PLAN NORTH `0 COPPER GROUND ROD IN TEST WELL O # 2 AWG SOLID TINNED COPPER WIRE AT GALV STEEL STAIR TO EGR (TYP) 1 3 8"=1'-0" � NO. DATE REVISION SCALE = 3/8"=1 ,-0" / O # 2 AWG SOLID TINNED COPPER WIRE FROM LIGHT TO EGR (TYP. AT (2)) KEY PLAN: AREA OF WORK GROUNDING NOTES CEDPF BIHCN ROAD,Wi qp,p, 1. ALL GROUNDING SHALL COMPLY WITH THE MOST RECENT REQUIREMENTS OF 12. ALL ANTENNA MOUNTING HARDWARE TO BE GROUNDED TO APPROPRIATE ANTENNA GROUND BARS. NEC ARTICLES 250 AND 810 AND VERIZON WIRELESS STANDARD NOTES AND CAST IRON FLANGE AND SPECIFICATIONS (LATEST VERSION). 13. ALL ABOVE GROUND CONNECTIONS SHALL BE INSPECTED FOR TIGHTNESS AND CORROSION (6) COVER WITH WORD 'GROUND' , rsI.D�A�,AaKro" I� 2• ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL GROUNDING INSTALLATION MONTHS AFTER INSTALLATION AND EVERY (12) MONTHS THEREAFTER CAST INTO COVER. //\\\j��\/ E Ifxll•, TAND HE INTTENTROFTTOHE DRAWINGS AND SPECTTE F CA TONS I TO DEPICIONEVERY IT IS OF 14. BETWEEN THE TWO ALS, USE CONDUCTORS WITH THE PROPER BIMETALLIC TRANSITION CONNECTOR INSPECTION HAND HOLE EQUIPMENT AND DETAIL BUT RATHER TO SHOW SYSTEMS TO BE INSTALLED. ASSEMBLY 15. METALLIC CONDUIT SURROUNDING GROUNDING CONDUCTORS SHALL BE GROUNDED IN PROVIDE SYSTEMS WITH ALL APPURTENANT EQUIPMENT OR COMPONENTS, WHETHER SHOWN OR NOT, TO MAKE A COMPLETE OPERATIONAL SYSTEM IN ACCORDANCE WITH NEC ARTICLE 820-40(A)5. PROVIDE GROUND JUMPER FROM BONDING BUSHING i� ��j�� COMPLIANCE WITH THE CRITERIA SET FORTH. TO NEAREST BAR USING # 2 WIRE AND OZ—GEDNEY TYPE HBLG BUSHINGS. GRADE 3. RESISTANCE TO GROUND SHALL BE 10 OHMS OR LESS, MAX. CONTRACTOR SHALL EMPLOY A GROUNDING EVALUATION COMPANY SUCH AS D&H SECTOR ALPHA SECTOR BETA SECTOR GAMMA ��\\�/\\\�/\\\j/\\\ ANT/MOUNTS ANT/MOUNTS ANT/MOUNTS DEVELOPMENT (515-461-2969) OR EQUAL. NOTIFY VERIZON WIRELESS \ PROJECT MANAGER IF THERE ARE ANY SITE SOIL/RESISTANCE CONDITIONS THAT MAY PRECLUDE OR HAMPER A PROPER AND COMPLIANT GROUNDING \\ � SYSTEM INSTALLATION. GROUNDING ARRANGEMENT SHALL BE TESTED FOR K ANTENNA K ANTENNA K ANTENNA �\\\ SUPPORTS SUPPORTS SUPPORTS COMPLIANCE WITH THE SPECIFIED CRITERIA. SUBMIT AN INDEPENDENT FALL OF CGK'S (�,P) CGK'S (11,P) CGK S (TYP.) POTENTIAL TEST REPORT. SHOULD THE CRITERIA NOT BE MET, CONTRACTOR GROUND SHALL COORDINATE ALL ENHANCEMENT WITH THE VERIZON WIRELESS PROJECT —O TEST LOOP MANAGER PRIOR TO THE COMMENCEMENT' OF SUCH ENHANCEMENT WORK. ' TY LPA DO NOT CAD WELD 4• FOR GROUNDING OF EQUIPMENT SHELTER, SEE SHELTER MANUFACTURERS O GAD BAR O GND BAR O GNDMMAR TO THREADS DRAWINGS AND SPECIFICATIONS. i CABLE TO ROD CAD 5. SEE GROUNDING SCHEMATIC FOR ANTENNA GROUNDING REQUIREMENTS. WELDED ynv 6. ALL CONNECTIONS ARE TO BE MADE TO BARE METAL. THOROUGHLY PREPARE CONTACT SURFACES TO ENSURE A PROPER CONNECTION (LE FILE PAINTED 0 � AREAS). PROVIDE COATING OF AN ANTIOXIDANT COMPOUND (NO—OX, OR EQUAL) s ON CONTACT SURFACES OF ALL CONNECTIONS. ALL BELOW GROUND TOP OF MONOPOLE SECTOR SECTOR SECTOR 3 CONNECTIONS AND EXTERIOR CONNECTIONS TO EQUIPMENT SHALL BE CAD ALPHA BETA GAMMA i BOTTOM OF MONOPOLE ( ;a WELDED AND SPRAYED WITH COLD—GALVANIZED PAINT. ABOVE GROUND MULTI. MULTI. MULTI. GROUND ROD COPPERWELD I "ORIENT POINT 2" CONNECTIONS SHALL BE CAD WELDED, GROUND LUG, OR COMPRESSION FITTED. CGK S CGK S CGK S » FOR GROUND LUG, USE STAINLESS STEEL_ HARDWARE CONSISTING OF TWO HOLE K K 3/4"0 X 10 —0 LONG LONG BARREL LUGS WITH A LOCK WASHER THAT SHALL BE PLACED ON THE NUT. O MONOPOLE NOTE: GND BAR #2 AWG SOLID TINNED 7. ALL METAL OBJECTS WITHIN 6' SHALL BE GROUNDED BACK TO THE EQUIPMENT AT&T GROUNDING SIMILAR. EXTERIOR GROUND RING o GROUND RING WITH #2 AWG INSULATED SOLID TINNED COPPER WIRE. T S CLEAN SAND FILL I : :d '..• i� io 8• ALL BENDS, CURVES, AND CONDUCTOR SPLICES SHALL BE TOWARDS THE U �', 40200 MAIN ROAD GROUND LOCATION (GROUNDED END) OF THE CONDUCTOR AND SHALL MEET OR NCEALME T EXCEED MINIMUM BENDING RADII. GROUNDING CONDUCTORS #6 AND LARGER SECTOR ALPHA SECTOR BETA SECTOR GAMMA • Q POLE NOTE: . :i.+ •. , ORIENT, NY 11957 SHALL HAVE A MINIMUM BENDING RADIUS OF 12", GROUNDING„ CONDUCTORS #6 ANT CABLES ANT CABLES ANT CABLES = INSPECTION HAND HOLE ; :�'i. :.• ;.. :\ \ AND SMALLER SHALL HAVE A MINIMUM BENDING RADIUS OF 8". — ELEC/TELCO RACK MAY BE PRECAST �+ MULTIPLE NOTE & 3 CONCRETE OR PVC AND TITLE: 9. UNLESS OTHERWISE NOTED, GROUNDING CONDUCTORS SHALL BE: n \ OK OK OK GROUND SHALL BE A MINIMUM OF • � +a• • •-• • • RODS F .. . . .. . ++•.. .•:....•.::•..:' ' "' .' . ��...• ' •'.;:.•..::••. .•. � A. BETWEEN EXTERIOR ITEMS AND BARS ,AND FROM SECTOR ANTENNA GROUND CGK'S CGK'S CGK'S EQUIP 12 I.D.X36 DEEP. BARS TO TOWER GROUND BAR, #2 SOLID, TINNED, COPPER CABS, :. �}.. ' .. '':' GROUNDING INFORMATION B. BETWEEN GROUND KITS & BARS — #6 STRANDED GREEN G D TYP . „ " , . ' ::•. THWN INSULATED COPPER GENERATOR C. EXTERIOR GROUND RING — #2/0 CONTINUOUS SOLID, C DATE: JULY 13, 2016 TINNED, COPPER PROJECT NO: 14-10823 10. GPS TRANSMISSION LINES SHALL HAVE AT LEAST (1) GROUND KIT INSTALLED AT DRAWN BY: MM THE WAVE GUIDE ENTRANCE PORT. MASTER GROUND BAROA CHECKED BY: TM 11. PROVIDE ALL NECESSARY GROUNDING KITTS AND HARDWARE AS REQUIRED. (SEE VERIZON CONDUITS (SEE CONC. PAD SCALE: AS NOTED WIRELESS ENGINEERING STANDARDS (LATEST VERSION) FOR ADDITIONAL GROUNDING GROUNDING NOTE #15) INFORMATION AND SPECIFICATIONS). W DRAWING NO: B MULTIPLE P Q E TYPICAL GROUNDING SCHEMATIC GROUND GROUND ROD TEST WELL- E�m = I 01 000. 2 RODS _ 3 SCALE = NTS = SCALE = 1 = V-0" SHEET NO: 10 OF 10