Loading...
HomeMy WebLinkAbout42915-Z aOSUFFQj1r Town of Southold 8/29/2018 P.O.Bog 1179 o - w' 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39870 Date: 8/29/2018 THIS CERTIFIES that the building WINDOWS Location of Property: 16109 Route 25, East Marion SCTM#: 473889 Sec/Block/Lot: 23.4-10.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 7/26/2018 pursuant to which Building Permit No. 42915 dated 8/2/2018 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issuedd is: window replacement as applied for. The certificate is issued to Jayne,Jeannine of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED 0A o ed Signature �9�g�FFot,r�oTOWN OF SOUTHOLD BUILDING DEPARTMENT a TOWN CLERK'S OFFICE CID • o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 42915 Date: 8/2/2018 Permission is hereby granted to: Jayne, Jeannine PO BOX 657 Orient, NY 11957 To: replace windows as applied for. X At premises located at: 16109 Route 25, East Marion SCTM # 473889 Sec/Block/Lot# 23.-1-10.1 Pursuant to application dated 7/26/2018 and approved by the Building Inspector. To expire on 2/1/2020. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $200.00 CO -ALTERATION TO DWELLING $50.00 Total: $250.00 Buildin d Inspector Form No.6 D [ECEVE TOWN OF SOUTHOL) BUILDING DEPARTMENT JUL - 9 2018 TOWN HALL 765-1802 BUILDING DEPT. APPLICATION FOR CERTIFICATE OF OCCUPANCY TOWN OF `S OLD This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building'or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. 7— g New Construction: Old or Pre-existing Building:J (check once)) Location of Property: l / Q//� 1 Q? ad lV ob!'­/11� 6 House No. Street Hamlet Owner or Owners of Property: �l ecz/7/'I//L Suffolk County Tax Map No 1000, Section o2 3 Block / -Lot- /Q. l Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: x (check one) Fee Submitted:$ pplicant Signature ��OE 50�T�o h� �O * * TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I SULATION [ ] FRAMING /STRAPPING [ FINAL W9I wdW`g [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: r DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (IST) ---------------------------------- G1 1 'FOUNDATION (2ND) P �HH�y • � lJ ROUGH FRAMING& y PLUMBING INSULATION PER N.Y: STATE ENERGY CODE FINAL ADDITIONAL,COMMENTS 0 o rn o i a b H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: 631 765-9502 LJ j Survey Southoldtownny.gov PERMIT NO. ` Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined —,20 Single&Separate Truss Identification Form Storm-Water Assessment Form Z ( Contact: Approved 120 Mail to: Disapproved a/c Phone: Expiration ,20 D Building Inspe CD]ArtLICATION FOR EUILDING PERMIT JUL 2 6 2018 Date e- o2 , 20 BUILDING DEPT INSTRUCTIONS a. This application be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. ;, b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housingcode, ad ions, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or narpe,if a corporation) (Mai ing add 7 of applicant) O State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises (6, /0 2Aa (As on t e tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which ro osed work will be done: �� /0 7 House Number Street Hamlet County Tax Map No. 1000 Section Block, j Lot c7 , Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use nd occupancy of proposed construction: a. Existing use and occupancy ��� b. Intended use and occupancy Sb r Dug l d 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work)0w1t7 ay i4 W I/ A �^ (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations_oradditions: Front Rear.,Depth Height Height Number of S,fbrIle's 8. Dimensions of entire new construction: Front Rear `= i Depth € Height Number of Stories ' ' 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner g z 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO • 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premises Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or•a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. . 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OFSQR__0 - L being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the Q( & T ( ontractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Swo to before me this CP day of SIA 20 0— BETSY A. PER S Notary Public,State of New Yo No.01 PE61 36 otary Public Qualified in Suffolk CounI ignature of Applicant Commission Expires July 18, `�" Jeannine Jayne Window replacement: Anderson 100 series-see catalogue enclosed 6 Casement(upstairs sunroom)+4 first floor all serial#16-3046-16 3 fixed pane(upstairs sun room) serial#30-6046-30 Bedroom 2 casement serial number CN145 upstairs fixed panel serial#30-6046-30 WINDO WS•DOOnS Andersen® CASEMENT WINDOWS BOO SERIES To s�Table of Sizes for Picture Window with Flanking Casements R P Scale 1/s"(3)=1'-0"(305)—1:96 A 5'-111/2" 7'-11 1/2° 9'-11 t/x° 1r-111/2P �t,,UIN TA Window Dimension (1816) (2426) (3035) (3645) � .12a^_FBUILDIIJG DT AT Rough Opening .—_(1829)__ _(2438) -- —_--(30481- ___R_.a x_ (3658)- V11-1_ Alai TO FOR TIDE 291/4^ 411/4" 531/4" 651/4^ 765-18 LING INSPEGT10P1S: (Uvnemob1m�s&ab))lass (743) (1048) (1353) (1657) pAT1UN - 'VO1REOUIRED Unobstructed Glass 11 1/a° 171/4° 231/<" 2s 1/a^ 1. F0U r_ CONCRETE (Mdth of&gle aaalbgsash) (286) (438) (591) (743) FO POOCtrc-ope, In 2. ROUGH - �� ,Ib$�f� BhfirPLUI�(IBIf�1G TI sGt"onary as viewed N �4m M too � � 0 000 ria ULA T 16-3010-16 20-4010-20 26-5010-26 30-6010-30 MAL _ fCr�lJj.th�te �r-&' �ON �IUST ~� N� ❑ ❑ DDD DDD D D COIVI�d��fcxoF�i Q@ C.0 ToE N cg MEET 16-3016-16 20-4016-20 26-5016-26 30-6016-30 tan,ar OUFS OF I GONS�fibn�3thel stan�af NE.W Ma ❑ ❑ ❑ ❑ ❑ ❑ ❑ 0 ❑ ❑ 0 REC IREN11QIq.5atr�s e �CC0 RUCT Olid 1ERRFOR 16-3020-16 20-4020-20 26-5020-26 3G-6020-30 STPavadabl ORS- �1-SIGN OR CONS .. � Z1 o1 M Transoms are also � �'C-j � � ❑ ❑ ❑ 0 ❑ ❑ ❑ 0 ❑ 0E= 16-3020-16 20-4020-20 26-5020-26 30-6020-30 shown. w CU aJ N110 N Windows have one N 16-3026-16 20-4026-20 26-5026-26 30-6026-30 continuous outer frame. Cn Opt I FE -- 16-3030-16 20-4030-20 26-5030-26 30-6 l 16-3036-16 20-4036-20 26-5036-26 30-603 -0 16 3040;16 20-4040-20 26-5040-260 P-6040-30 ` R1 I is n o I11, I t 6=3046- 20-4046-20 26-5046-260 30-6046-300 7 I i6 3050-16 20-4050-20 26-5050-260 30-6050-300 ti If 16 3056-16 20-4056-20 26-5056-260 30-6056-300 1t � � (D /L°�./ � `�t�v� /I ti ti I o N� .moi I / O .Z/t._ opo coo I LLL( \J ro (D v �'EUt'tf1r5 1t� 16-3060-16 204060-20 26-5060-260 30-6060-300 l •"Window Dimension"always refers to outside frame to frame dimension. •"Mlnlmum Rough Opening'dimensions may need to he Increased to allow for use of building wraps,flashing,sill panning,brackets,fasteners or other Items. •Dimensions In parentheses are In millimeters OMeet ar exceed clear opening area of 5.7 sq It or 0 53 mr,clear opening width of 20"(508)and clear opening height of 24"(610). 2014100 Senes Product Guide f Page 1 of 1 V CASEMENT/AWNING WINDOWS Table of Casement and Transom Window Sizes Scale 1/8"(3)=V-0"(305)—1:96 Window Dimension 1'-5" 1'-81/2° 2'-01/8° 2'-43/8° 2'-71/2° 2'-1115/16" 2'-93/4° 3'-43/4° 4'-0" 4'-81/2" (432) (521) (613) (721) (800) (913) (857) (1035) (1219) (1435) _----—�t— ,.— --5-... ._._.____-__....___-_.__,,...,._..._...._ ,_r..i_o Minimum 1'-5 h" 1'-9" 2'-0/e° 2'-47/8° 2'-8° 2'-10/a 3 5 Rough Opening (445)_ (533)_ — (625) -- (733) (813) (927) —� (870)- (1048) _ (1232) (1448) Unobstructed Glass 125/8" 161/8" 193/4" 24" 271/8" 319/16" 125/8" 161/8" 193/4" 24" (casement single sash only) (321) (410) (502) (610) (689) (802) (321) (410) (502) (610) Unobstructed Glass 123/16' 1513/16" 195/16" 239/16" 2611/16" 311/8° 2815/16" 3515/16" 433/16" 5111/16" (transom,single sash only) (310) (398)1 (491) (599)1 (678) (791) (735) (913) (1097) (1313) CUSTOM WIDTHS�i'_5_to_7v--OS '/a' mcal0 0 0�"FCIRlt 510 CTR1810 CM2010 CrR2410 CTR2810 OfR3010 CTR2910 CTR3410 CTR4010 CTR4810 m 'o mi -IR �� DO lZ7lTJ CM1810 CTR22010 CTR22410 I CUS70M_WIDTNS71 9C-4 0 [Ell 00 00 00 N p ml CR12 CN12 C12 CW12• CN22 C22 CW22' M LO M 1191 FEII 1031 B J ! a CR125 CN125 C125 CW125• CX125 CN225 C225 CW225' 1011 [Ell [Ell 01 [ON] M g CR13 CN13 C13 CW13• CX13 CXW13 CR23 CN23 C23 CW23' 07" t-� 0 FM [lid B Ed] 11M MM C0 j I CR135 CN135 C135 CW1350' CX1350 CXW1354 CR235 CN235 C235 CW2354' CR14 L`N14 C34 CW144' CX144 CXW140 CR24 CN24 C24 CW240' 11 Z:� ,;;t 2—11— 0 0 H 11 M 01 ( CR145 1145 C145 CW1454' CX1454 CXW145e CR245 CN245 0245 _ CW2454' TP 0 M M (�J ! CR15 CN15 C15 CW154' CX150 CXW154" CR25 CN25 C25 CW25e' NMI j CR155 CN155 C155 CW1554' CX155e CXW1554'• CR255 CN255 C255 CW2554' r W6 EN-1-6 C16 CW164' CX160 CXW164" CR26 626 C26 CW26e• •'Window Dimension'always refers to outside frame to frame dimension. •'Minimum Rough Opening'dimensions may need to he Increased to allow for use of building wraps,flashing,sill panning,brackets,fasteners or other Items. •Dimensions in parentheses are In millimeters 0 Meet or exceed clear opening area of 5.7 sq R or 0 53 mr,clear opening width of 20'(508)and clear opening height of 24'(610)with appropriate hardware,straight or split arm operator,specified •Meet clear opening width of 20'(508)using sill hinge control bracket with split arm operator specified(bracket can be pivoted for cleaning position)and meet clear opening width of 22'(559)with straight arm operator specified ••Available with straight arm operators only. 2013-2014 400/200 Series Product Guide Page 1 of 2 WINDOWS•DOORS Andersen® 400 SERIES 5'-23/4" 5'-115/e" 5'-1" 5'-117/a" 7'-05/e" (1594) (1819) (1549) (1826) (2149) 16 07) — (1832)_ T__ _(1562)_ (1838) 271/8" 319/16" 161/8" 19 3/4" 24" (689) (802) (410) (502) (610) 5715/16" 6613/16" 563/16" 671/16" 7913/16" (1472) (1697) (1427) (1703) (2027) Custom-size windows are available in 1/e"(3) 0 0 0 increments.Windows can also be custom sized CTR5210 CTR51110 CTR5110 CTR6010 CTR7010 to match standard sizes ending in a sixteenth of an Inch.Single windows only. CM22810 CYR23010 CM31810 CM32010 CTR32410 CN32 C32 CW32• CN325 C325 CW325' (eft Right Stationary Choose left,right or stationary as CX23 CXW23 CN33 C33 CW33' viewed from the exterior.In addition to venting shown in table,other standard configurations are available for single, CX2350 CXW2350 CN335 C335 CW3350' double and triple windows.Transom(CTR) windows are stationary only Double and triple windows shown have one CX240 CXW240 CN34 C34 CW340' continuous outer frame. —I` Transom(CTR)window can be used over CX2450 CXW2450 CN345 0345 CW3450' casement or awning windows and may be rotated 90°and used as a sidelight with MM casement,awning or picture windows. CX250 CXW250" CN35 C35 CW350' •'window Dimension"always refers to outside frame to frame dimension •"Minimum Rough Opening"dimensions may need to be Increased to allow for use of building wraps,flashing,sill panning,brackets,fasteners or other Items. •Dimensions in parentheses are In millimeters 0 Meet or exceed clear opening area of 5.7 sq ft.or 0 53 m=,clear opening width of 20"(508)and clear opening height of 24•(610)with appropriate hardware,straight or split arm operator,specified •Meet clear opening width of 20'(508)using sill hinge control bracket with split arm operator specified(bracket can be pivoted for cleaning position)and meet clear opening width of 22"(559)with straight arm operator specified —Available with straight arm operators only 2013-2014 4001200 Series Product Guide Page 2 of 2 WINDOWS•DOORS 400 SERIES Andersen® CASEMENUAWNING WINDOWS Custom/Replacement Window Size Range Available in 1/8"(3)increments between minimum and maximum widths and heights.Windows can also be custom sized to match standard sizes ending in a sixteenth of an inch.Some restrictions apply,contact your Andersen supplier. Custom sizing is available for single windows only.To achieve custom-size double or triple combinations,join custom-size single windows.For minimum rough opening dimensions for joined windows see specific joining Instruction guides Measurement guide for custom sized windows can be found at andersenwindows.com/measure. Minimum and maximum widths and heights. cusminWIDTHS(w) ; Casement Stationary/Venting ' nnoorsoonnnc —� (w)P-5"(432)to 2'-1115/16"(913) X (h)21-01/8"(613)to 5'-117/8"(1826) I y� uwaduauwnde ti noaanormnne rm"apl.Yuunnane M NO tfG4pgtll4 Casement/Awning Transom(CTR) = nrnoa rr.nu r tine ein°u c (w)V-5"(432)to 7'-0 5/8"(2150) X (h)V-0"(305) I uuwuue ,.intinc �uuuunr Ell a vi «U'r Custom/Replacement Casement Window Opening Specifications Clear Opg. width-window width-5.81"(148) Width x241/8'(613)with straight arm operator Min.R.O. width-window width+l/2"(13) -(window width-9.66"(245))X 1.07 Width x28 3/8'(721)with straight arm operator&control bracket ---, 'window width-9.70"(246) Width x17'(432)with split arm operator i� Height-window height+1/2"(13) Height=window height-4.43"(113) Height x40 13116'(1037)and<481(1219),Width x 28 318'(721)and<311/2'(800) ;' i -window height-4.85°(123) All other window heights Vent Opg, width-window width-5.81"(148) Width x24 1/a'(613)with straight arm operator Unobstr. width-window width-4.40"(112) -window width-6.10"(155) Width x 17'(432)with split arm operator Height-window height-4.95"(126) Height=window height-443"(113) Height x4013/1a'(1037)and<48'(1219),Width 228318'(721)and<311/2'(800) =Windowheight-4.85"(123) All other window heights •Dimensions In parentheses are In millimeters •Refer to andersenwlndows com/measure for detailed Instructions on how to properly measure for custom-size windows.