Loading...
HomeMy WebLinkAbout42731-Z �o�osuFFQlkcoGy Town of Southold 8/22/2018 o - P.O.Box 1179 co 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39860 Date: 8/22/2018 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 3025 Stars Rd, East Marion SCTM#: 473889 Sec/Block/Lot: 22.-2-20.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/21/2018 pursuant to which Building Permit No. 42731 dated 5/29/2018 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing sin leg family dwelling as applied for. The certificate is issued to Martem Management Inc of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 42731 7/24/2018 PLUMBERS CERTIFICATION DATED on 54tm�- /,I,/ Authorized Signature 0L I( TOWN OF SOUTHOLD ,,�� BUILDING DEPARTMENT a ` TOWN CLERK'S OFFICE o . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 42731 Date: 5/29/2018 Permission is hereby granted to: Martem Management Inc 664 85th St Brooklyn, NY 11228 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 3025 Stars Rd, East Marion SCTM # 473889 Sec/Block/Lot# 22.-2-20.1 Pursuant.to application dated 5/22/2018 and approved by the Building Inspector. To expire on 11/28/2019. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 Bui spector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00, Additions to dwelling$50.00, Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: '90an eG25L Lvm House No. Street Hamlet Owner or Owners of Property: M ae� Suffolk County Tax Map No 1000, Section Block Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: / Request for: Temporary Certificate Final Certificate: � (check one) Fee Submitted: $ t Si ature ho,\\pF SOUTyoI 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G Q Southold,NY 11971-0959 �oly� dao roger.richert(-town.southoId.ny.us �UNT`I, BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Martem Management Inc. (Michael Marinakis) Address: 3025 Stars Road city,East Marion st: New York zip: 11939 Building Permit#: 42731 Section: 22 Block: 2 Lot: '20.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: SUNation Solar Systems License No: 33412-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: 18.150 W Roof Mounted Photovoltaic System to Include: 55- Panasonic 330 Panels, 1- SE 11400 Inverter and 1- SE 5000 Inverter, 2-A/C Disconnects. Notes. Inspector Signature: Date: July 24, 2018 0-Cert Electrical Compliance Form.xls SO�TyOIo io TOWN OF SOUTHOLD BUILDING DEPT. 765-1602 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE,SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) REMARKS: t -Z DATE INSPECTOR'<F<N Fisher Engineering Services, P.C. PO Box 30' Oakdale • New York 11769 Phone: (63 1) 563-9028 June 15, 2018 D �cr5BV[2 D Town of Southold Building Department AUG 1 5 2018 Post Installation Certification BUILDING DEPT. Subject: Engineer Statement for Solar Roof Installation TOWN OF SOUTHOLD Residence: Marinakis—3025 Stars Road, East Marion Permit No. 42731 Installation Inspection Date: 06-14-2018 The roof mounted photovoltaic system at the above referenced residence has been generally observed to be installed properly in accordance with the approved plans and is certified-by-Fisher Engineering Services, P.C. to be in compliance with the minimum requirements of the Town,the 2017 NYS Uniform Code, 2017 NYS Uniform Code Supplement, 2015 International Residential Code (2015 IRC), Long Island Unified Solar Permit Imitative (LIUSPI), and National Electric Code 2014, and the provisions of ASCE 7-10. NEw Sincerely, William G. Fisher, P.E. Licensed Professional Engineer ' �f:tlij �c.•. .1-c a r" 1' ti.' iV` :L; 1r'. .S E1 .»'\i. !. - r� �- �', •t��.rwi - �.. Li- tits: t.7.:,9:'�}., i 'y � - �•{i e�+ -s(s�.ls 1, .�: �r,....-"}! s I zi Architectural Design•Residential•Light Commercial Additions.-Extensions-Conversions Construction Estimates/Oversight•Expediting•Inspections FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(1ST) H -------------------------------------- 'FOUNDATION (2ND) CN O a ROUGH FRAMING& y PLUMBING , INSULATION PER N.Y. STATE ENERGY CODE• FINAL ADDITIONAL COMMENTS ITA A ,7 str z z rn G, r d Mll IAV �l z° e b H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX: (631)765-9502 �ri Survey SoutholdTown.NorthFork.net PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined ,20_Lo Single&Separate Storm-Water Assessment Form Q Contact: Approved dk 1. 201 Mail to:SUNation Solar Systems,Inc Disapproved a/c t 171 Remington Boulevard,Ronkonkoma NY 11779 Phone:(631)750-9454 DBut dt pector MAY APPLICATION FOR BUILDING PERMIT Date ,201 INSTRUCTIONS TOWN OF soumow a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. ` e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signatu licant or name,if a rporation) SUNahon Solar Systems,Inc 171 Remington Boulevard,Ronkonkoma NY 11779 (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder SUNation Solar Systems,Inc-Contractor Name of owner of premises e 1 Ma a nay' s (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer Scott Maskin-President (Name and title of corporate officer) Builders License No.44104-H Plumbers License No. N/A Electricians License No.33412-ME Other Trade's License No. 1. Location of land on which proposed work will be done: '�09!5 <-540C House Number Street Hamlet County Tax Map No. 1000 Section Block Lot p�. Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Residence b. , Intended use and occupancy Residence with addition of Solar Panels 3. Nature of work(check which applicable):New Building AdditionAlteration� Repair Removal Demolition Other Work So ar Panus (Description) 4. Estimated Cost(s 5 t, �" Fee $200 00 (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law,ordinance or regulation? YES NO X 13. Will lot be re-graded? YES NO X Will excess fill be removed from premises?YES NO X 14. Names of Owner of premisesA(C.V&I WO(jyjILAddress 3XIS Y Pr1. OPhhoo e No. Rlc)--T Name of Architect wllllam G Fisher Address PO Box 30•Oakdale,NY 11769 Phone No 631-786-4419 Name of Contractor suNanon solar Systems,Inc Address 171 Remington Boulevard,Ronkonkoma NYPhone No. 631-750-9454 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO X *IF YES,SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? *YES NO X *IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property? * YES NO X * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF!) Scott Maskin-President-SUNation Solar Systems,Inc being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before met is l day of 20k_ JWm-&/M 'U n NotaryPublic Si of AppI cant VICTORIA M W4KER NOTARY PUBLIC-STA E OF NEW YORK No. 01WA6S19756 Qualified in SufYolk CoLrlfy Mfr Commission Expires February 29+•2019 Scott A. Russell 01'0 SU 'r�� ST01KMWA ]F1E]K SUPERVISOR MAN SOUTHOLD TOWN HALL-P.O.Boz 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 g Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DO]ES TMS IPROXECT INVOLVE ANY OF THE ]EO]LWWIING: Yes No (CHECK ALL THAT APPLY) ❑ . Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑ . Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑ D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑ . Site preparation within the one-hundred-year f loodplain as depicted on FIRM Map of any watercourse. ❑ F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT (Property Owner,Design Professional.Age t,Contractor,O ier) S.C.T.M. #: 1000 Date. District NAME 1 — 0q OBJ' I r i Section Block Lot �tg°" ** "FOR BUILDING DEPARTMENT USE ONLY**** Contact Information t Reviewed By: — — — — — — — — — — — — — — — — Date: d Property Address / Location of Construction Work: — — — — — — — — — — — — — — — — — ElApproved for processing Building Permit. Stormwater Management Control Plan Not Required. Stormwater Management Control Plan is Required. (Forward to Engineering Department for Review.) FORM # SMCP-TOS MAY 2014 Town Hall Ami" Telephone(631)765-1802 54375 Main Road (631)765-05 roger.richert own.SoUt ofi P.O.Box 1179 py.US Southold,NY t 1971-0959 BUILDING DEPARTMENT TOWN OF SOLTMOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Gina Date: 4-26-2018 Company Name: SUNation Solar Systems, Inc. Name: Scott Mtiskin License No.: 33412-ME Address: 171 Remington Blvd, Ronkonkoma, NY 11779 Phone No.: 631-750-9454 JOBSITE INFORMATION: (*Indicates required information) *Name: Michael Marinakis *Address: 3025 Star Road, East Marion, NY 11939 *Gross Street: *Phone No.: 631-477-8652 Permit No,: a—)51 TaxVap District. 1000 , ection: 22 Block: 2 Lot: M1 *BRIEF DESCRIPTION OF WORK(Please Print Clearly) ' 18,150W Roof Mounted Solar PV System Including: 55-Panasonic VBH N330SAl 6 PV Modules. 1-Solaredge S E I 140OA-US Inverter W/Disconnect and I-Solaredge SE500OH-US Inverter W/Disconnect. (Please Circle All That Apply) 1s job ready for inspection: YES/ NO Rough In Final *Do-you need a Temp Certcate: YES/ NO Temp Information(if needed) *Service Size: I Phase 3Phase 100 150 200 300 :350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: RAYMENT'DUE WITH APPLICATION B2-Request for Inipection Fonn pf SO!/l�Ql Town Hall Annex Telephone(631)765-1802 54375 Main Road y Fax(631)765-9502 P.O.Box 1179 G • Q Southold,NY 11971-0959 'Q BUILDING DEPARTMENT July 30, 2018 TOWN OF SOUTHOLD SuNation Solar 171 Remington Blvd Ronkonkoma NY 11779 Re: Martem Management, 3025 Stars Rd, East Marion & Reventlow, 1000 Stillwater Ave, Cutchogue TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: NOTE: Post installation engineer's certification letter required stating the panels were installed per NYS Building Code Electrical Underwriters Certificate A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 42731 & 42764- Solar Panels SUFFOLK COUNTY DEPT OF LABOR, I LICENSING&CONSUMER AFFAIRS MASTER i ELECTRICIAN SCOTT A MASKIN This cerf1 s that the' SUSVESSNAMr; bearer is duly SUNATION SOLAR SYSTEMS INC licensed by the County Of Suffolk Number an. 33412-ME 06/24/2003 Oormiasbner MMOATION GATE 0610V2019 New York State Insurance Fund Workers'Compensation&Disability Benefits Specialists Since 1914 199 CHURCH STREET,NEW YORK,N Y.10007-1100 CERTIFICATE OF WORKERS' COMPENSATION INSURANCE Rol' rr � ^AAAA 753118816 " SUNATION ROOFING SERVICES INC 171 REMINGTON BOULEVARD "a RONKONKOMA NY 11779 SCAN TO VALIDATE AND SUBSCRIBE ` POLICYHOLDER CERTIFICATE HOLDER SUNATION'SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 22160 670-2 617762 01/01/2018 TO 01/01/2019 5/21/2018 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY NEW YORK STATE INSURANCE FUNC DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER:539976195 Lvn� APPROVED AS NOTED DATE:"5 o B.P.' _'U-27sV. RM WATER RUNOFF RETAIN STI FEE: - ��� � BY: - `� PURSUANT TO CHAPTER 236 NOTIFY BUILDING DEPARTMENT,k AT-- 76.5 4802 8 AM TO 4 PM FOR THE OF THE TOWN CODE. FOLLOWING'INSPECTIONS:. 1.-FOUNDATIQ141 - TWO REQUIRED ,,,FOR POUF:CONCRETE I -ROUGFI"w"AWING 8� PLUMBING 3,,INSULATI6h- 4. FINAL`.= ' Fisher Engineering Services, P.C. PO Box 30 • Oakdale •New York 11769 Phone: (631) 563-9028 May 14 , 2018 Attention: Building Department Subject: Engineer Statement for Solar Roof Installation Marinakis Residence- 3025 Star Road, East Marion,NY I have verified the adequacy and structural integrity of the existing roof rafters for mounting the solar collector system (photovoltaic system) and its installation satisfies the structural roof framing design load requirements of the 2015-International Residential Code and the 2017-New York State Uniform Code Supplement, Long Island Unified Solar Permit Imitative (LIUSPI), and National Electric Code 2014. 1 have reviewed and certify that the manufacturer's guidelines and equipment for the photovoltaic system for the above residence meet the requirements for wind and snow load and that the roof structure is adequate to carry the new loads imposed by the System. For the installation of the solar mounting, the rails shall be securely anchored to the rafters utilizing lag screws that have been designed for wind speed criteria of 130 mph and snow ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and geographic design criteria are not applicable to this solar installation. The installation shall be in accordance with the minimum requirements certified by this letter. The existing roof rafters are 2"x8"& 2'x6" on 16" c.c., with actual spans of 17'-2" & 11'-2"with plywood roof decking and one roof shingle layer on the house as shown on the drawings. There are no structural modifications planned or required for the existing roof. ,1 I hope that this letter serves and meets with the approval of the Building Department. Sincerely, pF NEW r0 Z, William G. Fisher, E. Licensed Professional Engineer 07 Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections HIT. Panasonic Photovoltaic Module Panasonic's unique hetero unction technology uses ultra-thin amorphous silicon layers.These thin dual layers reduce losses, resulting in higher energy output than conventional panels Tab Flaps, n•type crystalline elllcan ooublo-aided textured surf.. -- ''-+ `NP'� '^ I•Yypo amorphous layer WThoaoamorphsusallloon Nysro _ raduoae the minimbin 1-1 of Amorphous lays, olaetrsne to minimum level. Transparent electrodo(TCO) Lattice type electrodes UNa•Nln omorphoue a1llcon layer Elootrodee Advanced bifacial cell designed for increased energy output. The cell utilizes sunlight reflected back from the rear side material which captures more light and converted into energy. Panasonic Conventional R- Back Sheet Beck-Sheet ' Our competitive advantages High Efficiency at High Temperatures 25 Year Product and Performance Warranty" As temperature increases, HIT°continues to Industry leading 25 year product workmanship perform at high levels due to the industry leading and performance warranty is backed by a century temperature coefficient of-0 258%/°C. No other old company- Panasonic Power output is module even comes close to our temperature guaranteed to 90.76%after 25 years, far greater characteristics That means more energy than other companies. throughout the day. Quality and Reliability Higher Efficiency 19.7% Panasonic's vertical Integration, 20 years of Enables higher power output and greater energy experience manufacturing HIT°and 20 internal yields HIT°provides maximum production for your tests beyond those mandated by current limited roof space standards provides extreme quality assurance. ®®® Low Degradation Unique water drainage ®®® HIT"N-type" cells result in extremely Low Light //® The water drainage system give rain,water and Induced Degradation (LID) and zero Potential snow melt a place to go, reducing water stains and Induced Degradation (PID)which supports soiling on the panel. Less dirt on the panel means reliability and longevity.This technology reduces more sunlight getting through to generate power. annual degradation to 0.26%compare to 0 70% in conventional panels, guaranteeing more power for the long haul HIT®Is a registered trademark of Panasonic Group HIT Panasonic Photovoltaic ModuleLL \_CCl`1`J-od\9lT ELECTRICAL SPECIFICATIONS PERFORMANCE WARRANTY 100% 97% Rated Power(Pmaxll 330W 325W 9s% Maximum Power Voltage(Vpm) 58 OV 57 6V 9076% Maximum Power Current(Ipml 5.70A 5 65A _ r2P ° 2ower Open Circuit Voltage(Vocl 69.7V 69.6V ss% 25 y.... Short Circuit Current(lscl 6 07A 6 03A so% es% Temperature Coefficient(Pmax) -0,258%/°C -0 258%/°C -_ —_ - - — — - 75% Temperature Coefficient(Voc) -0 16V/°C -0,16V/°C Temperature Coefficient(lscl 3,34mA/°C 3,32mA/°C 70%o s 10 1s 20 25 NOCT 44,0°C 44.0°C ■Panasonic ■conventional CEC PTC Rating 311,3W 306.5W Ceti Efficiency 2209% 21.76% DIMENSIONS Module Efficiency 19,7°/4 19,4% 511053] 38[351 203[516 51 _ 11 Watts per Ft 2 18 3W 18 OW l 'Maximum System Voltage 600V 600V - I Series Fuse Rating 15A 15A Warranted Tolerance(/+) +10%/-0%- +10%/-0%' A A' ^� MECHANICAL SPECIFICATIONSModel r I t O (D Internal Bypass Diodes 4 Bypass Diodes Module Area 18,02 Ft 2(1,67m21 I 397110091 T i Weight 40 81 Lbs 118 5kgl I Dimensions LxWxH 62 6x41 50 4 in.(1590xlO53x35 mm) Ll Cable Length+Male/-Female 40 2/40 2 in (1020/1020 mm) M0Y �ra0ans Cable Size/Type No 12 AWG/PV Cable Connector Type' Multi-Contact®Type IV[MC4TM) °J ----' '---- `� 0797(2025]0 L�994JH_Hj�j� Static Wind/Snow Load 50 PSF(2400 Pal Pallet Dimensions LXWXH 63,7x42 2x65.4 in 1260[321 1457[371 Quantity per Pallet/Pallet Weight 40 pcs /1719 Lbs [780 kgl Unit inches(mm) Section A—A' Section B—B' Quantity per 40'Container 560 pcs Quantity per 20'Contamer 240 pcs DEPENDENCE ON IRRADIANCE 700 100ow/rd OPERATING CONDITIONS&SAFETY RATINGS 600Model — VBHN330SA16.VBHN325SA16 500 80ow/ni a Operating Temperature -40°F to 185°F I-40°C to 85°Cl � 400 Hail Safety Impact Velocity 1"hailstone(25mm)at 52 mph(23m/s) ` 300 aooW/ni Safety&Rating Certifications UL 1703,cUL,CEC - - - 200 UL 1703 Fire Classification Type 2 I200W/rd Limited Warranty 25"Yrs Workmanship and Power Output(Linear).". 100 000 NOTE Standard Test Conditions Air mass 1 5,irradiance=1000W/m2,telt temp 25°C 0 10 20 30 40 50 60 70 80 'Maximum power at delivery For guarantee conditions,please check our guarantee document Voltage IV) "Installahon need to be registered through ourwebsne www nanasonrcusahitwarranty corn within 60 days Reference data for model VBHN3305A16 in order to receive twenty-five 1251 year Product workmanship Otherwise,Product Workmanship will be (Cell temperature 25°CI only fifteen(15)years •"Istyear 97%,after 2nd year 026%annual degradation toyear 25 A CAUTI0NIPIeasereadtheinstallationmanualcarefu[lybefore usingtheprod ucts 'STC Cell temp 25°C,AM 5,1000w/m' Used electrical and electronic products must not be mixed with general household waste For proper treatment, 2 Safety locking clip(PV-SSH4)is not supplied with the module recovery and recycling of old products,please take them to applicable collection points in accordance with NOTE.Specifications and information above may change without notice your national legislation 1 solar=a@ SolarEdge Power Optimizer Module Add-On For North America OP250-LV/ OP300-MV/ OP-400-MV/ OP400-EV vi RsRF,�_ ^ W xb�n�t- �,,yvk�` f,;t"°'." rx.�., � .p 'L "V I 1 J _. l ^{�_�•.`�s �Ak�aY '�{ . Al �.�i�'F,r rdYa i- '4'� ,tt:eA :i-.: yp �"� .lti! _ •-ffd:. �i�+fi.'S_ x` "r. x ,04 ' to ONE 1 141 F."' :rQ'i- FL,:.«�`- '•r4• - R�r .�.,.r..,- :C:`. i F '° «�4.'A i� ,h 6e..,:�' - - - _ -.}� _ r+ip'- - "a`:` I?°.�i"�_. K�,`S iT.:"s'?.<'.''w,' .... .:'�.s`S. .iN'✓t .�,• - - 4�• _ _ i'L� ."f u rt 54 a P�.�.. Y4' a+:sin.=.>n o>�nrer o � tir>r ` I? �za#ion .�. odute=ievel�� to - ^ p SuperiorJcfictency{99:S%j Mtigates.ati types of module mismatch losses,,fr_orn manufacturing tofeiance-to.partial-shading; Fle%fe sysiem:design foi r»aximum space uti f' nation ir tNext-generation maintenance'W!6 module-16e1 monitorin _=Module=level woitagq sfiutdoii✓n for installer anii'firefigtitersafety = USA - GERMANY ITALY •- FRANCE JAPAN CHINA ISRAEL - AUSTRALIA WWW.SOlaredge.us sola ®larEdge ®wer Optimizer Module Add-On for North America 0P250-0V/ OP3004AV/ OP400-MV/ OP400-EV OP250-LV OP303-MV ;_OP400_MV -I- OP400-EV ,_--__ INPUT Rated Input DC Power* 250 300 400 400 W Absolute Maximum Input Voltage(Voc) 55 75 75 ! 125 Vdc MPPT Operating Range 5-55 5-75 5-75 15-125 Vdc Maximum Short Circuit Current(Isc)of connected PV 10 10 10 7 Adc Module Maximum DC Input Current 12.5 12.5 12.5 8.75 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 /a Overvoltage Category OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current 15 Adc Operating Output Voltage — 5-60 y -Y4 Vdc — OUTPUT DURING STANDBV(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 j Vdc STANDARD COMPLIANCE - — EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class 11 safety),UL1741 Material UL-94(5-VA),UV Resistant RoHS _ j -- Yes INSTALLATION SPECIFICATIONS_ _ Maximum Allowed System Voltage 1000 Vdc ... ... . . 1. 1..... ......... .. . .. .... ............,<. .... ... ........ .. .. ......... . _.... Dimensions(WxLxH) 143x210x45/5.63x8.26x1.75 mm/in l. ; Weight 450/1.0 gr/Ib input Connector - - -- -- - ----- -- = - - - ---- MC -/Tyco-/-H+S/Amphenol---H4 -- - - . ... ., .. ;...,... .,. Output Wire Type k Double insulated;6mmz;MC4 .... I Output Wire Length 0.95/3.0 0.95/3.0 1.2/3.9 I 1.6/525_.,i m/ft Operating Temperature Range -40-+65/-40;+150 •C/'F Protection Rating IP65/NEMA4 Relative Humidity 0-100 % Rated STC power of the module Module of up to+5Y power tolerance allowed. PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V INVERTER Minimum String Length(Power Optimizers) 81 8 18 Maximum String Length(Power Optimizers) 25 25 50 Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths or Orientations Yes ' -��' R19 SOLAR SYSTEMS m v d►[•3 � ?ar:rtnq /0U( wc+rld 1217 Montauk Highway,Oakdale,NY 11769 v ., a'` r •za _ .`a• a, : s s 631-750-9454 .+!-. - i- , r B.r S•. Yb a,• www.sunationsolarsystems.com A �e'a�"s:., �+"�',•``" ''.fit '�y "�'--+,_ '^.�': � ""s; �s= �' �Y raq fur w'Yn,l� '>{:�^`..''''_. '�'- •„�.,, € m'e.'.r., .,'t•'-��'�� -r;tti+c?:mr"...,•, •._„ray..'a�k�'at'.'�ay.'4xiY .,5i"�,;>':'�,.�,i. ;., "+t. 't'�✓-'ai1 Pk, �•g' 'y w4,�"f"' np S�"`t'` #.s ,,�; a'��.,=',.-4.� }=a3vva,'Y,Pn'wS;,•;,.a'i$x.-, .r"�6:c �"�: 'Mrw''i ,�. -fi �„ tib, ,�`:a�M '��&.s•�:aK.y>:,..., .:Ca ,. . 11 E19 S ola S®IarEdge Single Phase Inverters * For North America `�"�";'R"d.'rid.4..] •girLa X„v' .`?,t ,e. `s X t.w: 9-. <.p%y",''{ SE3000A-US/ SE3800A-US/ SE5000A-US/ SE6000A-US :`"v, SE7600A-US / SE10000A-US/ SE11400A-US 1 , y �L'r;-"e f �x s5--`�.�•,.".•�>^�'tri;,,'-a; hr... ,�~ ,y� �.e F71 ,:.w' '� m-�h - :"}a 9. -..,. Z:`✓.�.3'_w- ..�m'»y.3°"..:�_' �_�i�yu4'kA1,:'.�"'. m J 'IS y Ra 2T.�t a <eC„�.'�+dc +�h..�:.'$d::.."'b.4 '•�' �''�`" r f'r!�' �'`��`, MX rt a{..�4'��' 9 vr'1 '�,. ,,Y ,�"X j` , .3 �a 1, .�Y�'a' ;-'d°' ''� '�i d4 -§ ?Y"^-,�'.« g�•t..." `C'% :: 9"_ ._ ':tib,,. ,�+�..?-. •�, • ,,.,�,',.,,,;s"�;',;:''+?''a.;.;v,,.: .,. :,a .,a..,. P�:a"cf—;¢.,P: g.1. .%',3. 'v r' ,.k:r- €...,�.A.N•� ��:"' v,,z:�r ,�X $^� "Ns:. e ' -� ��F3S, _ .r 'fV'�. , ��.:t , .}"r1`'.,� �t t •vx.,'1b��e ..T'"'i' ^6 1 Z~ p., �•�ren' �t. r' e .A-v ^;i?o, b rti •�-a.;'��tr'e,��&:_`_.��.r,«:�,a :`+�:o..,.rs'`vo i .5 + }'�-, +a.u}, y���.iy' a.ate,''-`, $i• .;� '"'.{,new'' "-'§° ,�' ,,,, , � " ^ $° i^aY•��'"M. �e~�rW>(N-'^":'✓�� { .. � ,,�# ins '�y°'�'A r�..�^.,i�a;,;�''s�,^'` ,'; 'k.ti i>' 'r��3'1`„''.',':.�,v. '..`" 'x r. �s:5,>Y`,e^ ,',`�J" a':,t"*ap:•. dN;:2-�'�t�X<' r - '•'^ce +r,3't»'"` ."mP i,'f'.. �4'._,.i'+ .Wi';•,.A,c.°:._.,..'-"3.'„1 'v', aY{ +'4 ^,ate s<��p.�t�,i.�!yi,�: er� cU' `a' "Qw 4"ti"�'`o"- r• .yr'aRY..? i°y;- :',: -' � 4aw ,�>,,,� '�P"' §Nw,�:;^s'S�>�'"R',,",�:'�'i'-',yr',a.' a'!,.v �,;.•' ,;,�, 'R: �,.� i.�".r,.^ :�:'k. `i-.;.f>, .''f� '�ti'i',�;:,,. ;' ;"t'*' .'v«.a k•s , ." •t, r .�,es a' ;e.'r:< ,>�'<. : .i a` •ti "'£' - ' '�•. � ' .<u�gry �'"'.� "±..5 ta�,�< '�',";,**boa' .. ! "{ - -'. �.- 'a. .;,w �k.'z"-'^ ••.,�.;.�=•fir c?.a>.�.."- .Y".%°.,;,� ,.�;>z� • � -, 'z+.��'"�-r.k�a<. �'b,,,'' �'s*,.���;''+' ' �,ng g ^';,-"P„� sr,.<'' �j:' '�';s;.-'a`y."�<,S'', �,:tl w:2:,e,}6,i•s•.. d- n,'��;.. { W'v'#,'{y:tgryti„� l"''.-3 @'�'✓.E Cr "U ' e�,. :yi.y,a, ,'d"^:;.';d, c. �}' ,�.• .. s6i+ irr"•a a� «�Q✓-,, 7, �'�;�..� u ",'_��:§ x `+'i�`�:,,�"C• '^ 5t..•`'��'»'o-'-,.'f F•<^.�-ga;•,3,�,Y �ra•. •f,=. t��.a .v,z.:a"&a,..`�.' q "& ' .�Ps}•h:�w `.Fiu 7 Y ,dx-.ua, k'„ ,Jr.•'r:' ,, =•i ' yP}id'.'� $"^ yn' ,1;'p" '�g,;� T6W'A'.'- r �, � •� �f^,t'". w;.S:°c y„.r:,�a as'"�'r�'�w-'r,�'��."�v i^;L�,atv:''�'_ 'p 6.;,.s'•.;i-"",<"�,'i":,�,1 �c K°"s^^ia"�,. �« �4:.°-...s..,,p-. ' ,� �!,e �;'. � i „`' r" �tl -. :,e'rk'.,,1• $".``*,;,a"SgrF .�?:s'::•�� ;�.�y,��}..y � "u �?..:,5"�'$d,:J^$': 1 �,a.,:«. 'a`»w'"4�•: 'a..�;,s',4" `�,",,, .}-'4`a�,r,,.... '" 'a:`.wa{', w�w}^*" �Q:;+,". • ' „� - Y, '���#.'«,% a-�;;�-`' ���I.._3,� ' ,�g''.;?:%s,::.,�'a•'�',c='r;"'" �''-s�": �� a'in, � �, 'ar°"^'r�,�rn«,.,- a;: ( .. a 4 :'>< e,s.._ __.•... ,: (i}=. Thesbest cbolce f6e S`O-a.IrEd a enabled sy. tei ms lhtegrated'arc fault,protection(Type1)for NEC.2011-690.11 compliance(part numbers ending in Superior,,iAciency{98%) j l ' ^,Small,lightweight and easy to.install on.provided bracket" �. .Built-in module-level monitoring Internet connection through'Ethernet or Wireless I , 3 Outdoor and indoor,installation Fixed voltage inverter,DC/AC conversion only, Pre=assembled AC/DC Safety Switch.for faster installation USA GERMANY ITALY FRANCE - JAPAN - CHINA - ISRAEL AUSTRALIA www.solaredge.us i s® ar' � oo Single RhaSe Inverters for North America SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE760OA-US/SEt0000A-US/SEl140OA-US SE3000A-US SE3800A-US SESOOOA US SE6000A-US SE760OA-US I SE10000A-US I SE1140OA-US OUTPUT Nominal AC Power Output 3300 3840 5200 @ 208V 6000 7680 9980 @ 208V 11520 VA ........................................... ................ . 5520 @240V 10080 @240V .............. .......... ...... ................ ........ ....... .................. .................. ........... Max.AC Power Output 3650 4150 5600 @ 208V 6000 8350 10800 @ 208V 12000 VA 6000 @240V 10950 @240V ......................................... ................ ............... ................. ................ ................ ...... ........... .................. ........... AC Output Voltage Min-Nom-Max .................... ............... ............... ................. ................ ................ ........ ......... .................. ........... AC Output Voltage Min-Nom.-Max* ✓ ✓ 211-240-264 Vac ..................................... .. ................ ............... ................. ................ ............ ... .................. .................. ........... AC Frequency MinAom:Max* 59 3-60-60 5(with HI country setting 57-60-60 5) Hz 25 @ 208V 48 @ 208V . .... .... ....... ........ Max Continuous Output Current 14 16 25 32 48 A 23 @ 240V 42 @ 240V ..... ......... ......... ......... .... .... ......... ............... . ............ ................ ........... ......... ........ ......... . ....... GFDI 1 A .................................. ................. .......................... ...................... ..................................................... ........... Utility Monitoring,Islanding Protection,Country Configurable Yes Thresholds INPUT Recommended Max DC Power** 4100 4800 6500 7500 9600 12400 14400 W (STC) ..... ............... ................. ................ ................ .................. .................. ........... . ............................. . Transformer-less,Ungrounded Yes Max Input Voltage 500 Vdc ........................................... ................ Nom DC Input Voltage 325 @ 208V/350 @ 240V Vdc Max.Input Current*** 11.......I......13......�...17 @ 240V..�.......18....... ......23. ...... .30.5 @2040V..�.......35........ ...Adc.... ........ .................................. Max.Input Short Circuit Current 30 45 Adc ................................ . ... ............. . ................ ........ Reverse-Polarit Protection Yes ....y................... .... ........ ............................. ......... ........................................ Ground-Fault Isolation Detection f 600knSensitivity Maximum Inverter Efficiency 97.7 . 9........ .. 98 3 98.3...... ......98...... ..... 98 98 CEC Weighted Efficiency 97.5 98 97 5 @ 208V975 975 97 @ 208V 975 % 98 @ 240V 97.5 @ 240V .... ....................... ............ ................ ............... ................. ................ ................ .................. .................. ........... . Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional) STANDARD COMPLIANCE Safety UL1741,UL16996(Part numbers ending in":U'.),UL1998,CSA 22 2 ........................ ........... Grid Connecfion Standards IEEE1547 .... .................................... ..................... .. .... ........................................... ...... ........ ........... Emissions FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4"minimum/24-6 AWG 3/4"minimum/8-3 AWG ................................... ............ ...................................................... ........... DC input conduit size/#of strings/ 3/4"minimum/1-2 strings/24-6 AWG 3/4"minimum/1-2 strings/14-6 AWG AWGrange..............I.............. ................................ . . .....................7. . ........ ................. .............. ..................... ........... Dimensions with AC/DC Safety 305x125x7/ 30.5x12.5x5 ./ 30.5x12.5x10.5/775x315x260 n/ Switch(HxWxD� 775 x 315 x 172 775 x 315 x 191 mm .................. ........................ . .............................................. Weight with AC/DC Safety Switch 512/23 2 547/24.7 88 4/401 Ib/kg ............... ... ................. Coohng Natural Convection Fans(user replaceable) ........................................... .............. .. ......... .. ... ............................... ................. .................................... ........... Noise <25 <50 dBA Min.-Max Operating Temperature -13 to+140/ 25 to+60(CAN version****-40 to+60) 'F/'C Ranke................................I.. . ......................................................................................................................... ........... ProtectionRating ......................................................NEMA 3R........................................................ ........... *For other regional settings please contact SolarEdge support **Limited to 125%for locations where the yearly average high temperature is above 779F/252C and to 135%for locations where it is below 779F/259C For detailed information,refer to htto//www solaredee us/files/Ofs/mverter do oversizme ewde odf ***A higher current source may be used,the inverter will limit its input current to the values stated *•**CAN P/Ns are eligible for the Ontario FIT and microFIT(microFIT exc SE11400A-US-CAN) -;a '^ _ -" w;ti, .'7' 3.""^'*', aa • ^r.' i�'n.''f°�'a:"'fi.`P�zY'^^�,a,, •, ,: • a �- "" t, ,�;. 9. nq—.`3�,y ♦*»1 +, ._ai.. if _ "' a., gmmv SOLAR SYSTEM S d®r9 t_ g �� �N4 �r„=•e�pys� ,.2 �� � � .. ,y, Powering your world 631-750-9454 sunationsolarsystems.com " 5''rfa'6 .'�� P "^ .17',?.}. '�3ar ate' g'"i•, `"`e"'�.,,».V^:. �< Solar=o@ y S®IarEdge Single Phase Inverterseo for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US _ i2��j•m4 �` (o 'Joh �.k. 91n a �u� •4-, 4 ._4_i6 „3t ,.. Optimized installation with H®-Wave technology ® ,Specifically designed.to work with power optimizer`s' Record-breaking efficiency l o -;,Fixed voltage inverter.for longer strings ` Integrated Arc Fault protectiori and Rapid.Shutdown for NEC 2014 and 2017,per articler690.11 and 690'.12. UL1741 SA certified,for CPUC Rule 21 grid compliance Extremely small and easy"to install outdoorssor indoors i High"reliability without any electrolytic capacitors9E! Built-in module-level monitoring wave ! Optional:`116enue,grade data, ANSI C12.20 Class 0.5(0'.5%accuracy) USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTH AFRICA-BULGARIA www.solaredge-us so I a r = ® ® � Single Phase Inverters for North America " SE3000H-US/SE380OH-US/SE5000H-US/SE6000H-US/SE760OH-US SE3000H-US SE380OH-US SESOOOH-US SE6000H7US SE760OH-US "OUTPUT Rated AC Power Output 3000 3800 5000 6000 7600 VA ............................................................ .......... Max.AC Power Output 3000 3800 5000 6000 7600 VA ...... ... .. ... .................................. . .................... .................... .................... .................... .................... . AC Output. .Voltage. . Min:Nom-Max.(183-208-229) ✓ - Vac ...................M.i .... m.......................... ................... .................... .................... .................... .................... ....Va ..... AC Output Voltage Min:Nom.-Max.(211-240-264) ........✓,,,,,,,,, ,,,,,,,,,✓,._...,.. ,,,..,,,.✓...,,.,,. ....,,,,,✓......,,, ✓ Vac ......................................................... . ................ . .... .... AC Frequency(Nominal] 59.3-60-60.5111 Hz ......................................................... .................... .................. .................... .................... ............. Maximum Continuous Output Current 208V 24 A ............................... .................... -.......... ....... .: ...... .. .... ..... ..... .. .. . . Maximum Continuous Output Current 240V 12,5 16 21 25 32 A ............................................................ ......... .................... ............. GFDI Threshold 1 A ....................................... .................................................. .................................................. ............. Utility Monitoring,Islanding Protection, Country Configurable Thresholds Yes INPUT ` Maximum DC Power 4650 5900 7750 9300 11800 W ............................................................ .................... .................... .................... .................... .................... ............. Transformer-less,UngroundedYes ............................................................ . .................................................. ............. Maximum Input Voltage 480 Vdc ............................................................ . ............................. .................... . ..... Nominal DC Input Voltage.............................. 380 4..0........ ....Vdc..... ................... . .................... .................... . Maximum Input Current 208V 1Zi 13.5 Adc ........ .......... Maximum Input Current 240V Rl 8.5 10.5 13.5 16.5 20 Adc ............................................................ Max.Input Short Circuit Current 45 Adc ............................................................ . .................................................. . .... Reverse Polarity Protection .. Yes ............................................................ . .................................................. ............. Ground-Fault Isolation Detection 600kaSensitivity ............................................................ .................... .. . . ............. .......... .. ........................ Maximum Inverter Efficiency 99 99.2 .... .... .... ........ . . ...... .. . CECWeighted Efficiency 99 .................................................... .... ............................. ................................................ ............. Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES, Supported Communication Interfaces RS485.Ethernet,ZigBee(optional),Cellular(optional) ......................................... ...................................................................... ............. Revenue Grade Data,ANSI C12.20 Optional() ....................................... ............. ...... ... .......... ........ _ ............. Rapid Shutdown NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741:UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 ............................................................ . ........................................ .................................... ............. Grid Connection StandardsIEEE1547,Rule 21,Rule 14(HI) ...........................I.......................... ........................................................................................................ ............. Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS, - I AC Output Conduit Size/AWG Range 0.75:1,' Conduit/14-6 AWG ......................................................... ............................. ........................................................... ............. DC Input Conduit Size/#of Strings/AWG Range 0.75-1" Conduit/1-2 strings/146 AWG .......................................... .. ...... ....... ................................ ............. Dimensions with Safety Switch(HXWXD) 17.7 x. x 6.8 /450 x 370 x 174 in/mm ............................................................ . . . ............. Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9 ..................................................I. f. ................1.................. ....... .... ..... .. . ... .. . ...... .. . Noise <25 < dBA ............................................................ ................................................................................... .............50....... ............. Natural convection and Cooling Natural Convection internal fan (user .......................................................... ...replaceable]... ............. Operating Temperature Range13 to+140/-25 to+600 (-40°F/-40°C option)15i °F/°C g....................................... ........................................................................................................ ............. Protection Ratin NEMA 3R(Inverter with Safety Switch) For other regional settings please contact SolarEdge support 1Z1 A higher current source may be used;the inverter will limit its input current to the values stated Revenuegrade inverter P/N,SExxxxH-US000NNC2 Power de-ranng from 50'C -40version P/N,SExxxxH-USOOONNU4 yry �;5' ,^§" '-i' t_�,r9�. Priv �s:-q -�^� -�. ^s.""-�" - •.r.• i 4 i th ca .. e e O e e • •e. e e Technologies,enotice. - SnapNrack- Series 100 Solar Mounting Solutions Flashed L Foot Y. Reliable & Weatherproof Roof Attachment Cutting of shingles not Preassembled, snap-in required P hardware reduces installation- time Single tool installation, using Included in Series 100 UL )j Y L standard socket 2703 • «� ..: - 1 '��' W..:.,$',• '�:q, .�-c, �.�o-e. -� ,� �> ,r"v r:'��, _ :y.i. � � -� .:;P,�"�i. `� ry���P.L�" #�„^* 'ti t" v 8, -R' RESOURCES snapnrack.com/resources * . DESIGN snapnrack.com/configurator WHERE TO BUY snapnrack.com/where-to-buy SnapNrack Series 100 Flashed L Foot Kit f - is an industry-leading, weatherproof solution for attaching to composition shingle roofs. The Flashed L Foot provides a fully flashed method for mounting the SnapNrack Series 100 system. The combination of Series 100 and the Flashed L foot is guaranteed to improve labor times and ensure the highest quality install possible. Flashing • Available in black galvanized steel or aluminum for enhanced corrosion resistance • L Foot is attaches to bottom edge of flashing, removing the need for shingle cutting • Innovative stamped features provide - increased rigidity k." ,M1. L Foot • Engineered for maximum adjustability with the ability to orient in any direction • Vertical adjustability up to 3" using available spacers f R' L Foot Base • Provides a long lasting watertight seal over the life of the system that does not rely on rubber (elastomeric seals) that will degrade over time • Easily installs with off-the-shelf lag screws yr Channel Nut Provides snap-in installation to the rail channel with no drilling required Wide range of adjustability due to sliding ability in rail prior to final tightening e F tuality. Performance . Innovation , SnapNrack solutions are focused on simplifying the installation experience through intuitive prod- . • the best wire managementindustry. SnapNrack Solar Mounting Solutions • _ :'S'C':'OSW.it.'�Y.4{,`"`c'!'k!M^i•,t�3„ .h�',MotwnAkd.OiniSR°'=?e;.'ASS".:.>,ik�.INx",'IF: 4 „u "� rLL d'Y `�'•,,< !., �. "-;"'*��"$':�v.a+us^'" x...c .� ',so- �.s,'��y�„ �_,�,, �._ "s. c — ' - Entire Mounting System from , Snap-in features make the Single Manufacturer under 1 v`' install process intuitive and Warranty fast .Industry Leading Technical U The Most Comprehensive UL Support Services for Every o 2703 Listing in the Industry Customer '1 +s • 1 a t .t,i" %• af•"�.; d" =r rCr..�f.F #•'�� � .� �+ i'� ^a4 •''Y ,,.'� d�,. es d `s,� �� ,• .v a'� x+^� •n. r�' a,i� p' •„_,e n r •fit' i �:■ itxt._. y'.' i "RUE 1 � 1 T: he SnapN rat, lkSleries,­10G Rdof M 6­ untSysteft ' ' • ' . • • ' 1 The top-of-the-line features of the SnapNrack mounting system reduce install times and labor cost while eliminating the need for service calls creating the lowest install lifecycle cost of any mounting system. Wire Management rA ; • Products such as the standard rail channel keep wires neatly organized providing a clean finished look to every install • Industry's largest offering of wire management accessories include snap in junction box, 4-wire and trunk cable clamps, as well as conduit clamps for both composition shingle and tile roofs. Undeniable Aesthetics • Render the mounting system invisible by using Universal End Clamps that fasten modules while remaining hidden underneath the array • Array skirt provides a sleek look and attractive design to the front of theWE array • Rail-based system provides rigid structure tucked away underneath array with no unsightly mounts at the top or bottom u a 'i it YO Performance . - I'll Innovation , IT products and the, best wire Manageme�nt in the' industry. SnapNracki �oll§rMoUhtin.g solutions 877-732-2860 ra . - - • • 3 tVe L � W System designed with Easier logistics through simple maximum versatility for anybox packaging and no long rails arrays including staggered rot Simple design allows system to Drop-in features make the be installed by single installer install process intuitive and fast on the roof "AS"SNIM 1 :' a�- A C', 'instaillex • - • • - • • Flash Track with Patented Umbrella Technology • Single Umbrella lag screw secures flashing and flash track to roof • Umbrella technology provides weatherproofing with a long-lasting mechanical seal • Flash track is designed for maximum versatility with 6 inches of North-South adjustability for A Mounts and B Mounts A Mounts • Provide a sleek attachment point for the front of the first row in an array • Drop-in design means no securing of modules is necessary as they simply slide into place B Mounts • Simple design provides mounting platform between rows of modules • Clamps onto top of module securing it in place while providing row- to-row bonding • Next row of modules easily drops into place as with the A mounts C Links • Easily connect rows of modules by sliding between each module pair • C Link clamp rotates 90 degrees to provide sleeve i attachment for bottom of module • Clamps onto both modules on the top of a row to provide mechanical and electrical connection ' Wire Management • New Smartclip design fi rmly retains wires within the • module frame preventing them from being pulled out • Wire Saver provides a simple after install solution for securing hanging cables Qua� lay, Innovative , Superior Snap N rack'Solar kou,nting Solutions ar&engineered to optimize materrall use and labor resources • improve overa.11 installatio,nq6al,ity and 817-132-2860 t UTILITY METER- OF PLAN KEY SERVICE DISCONNECT- G.. PV-i SITE PLAN MAIN SERVICE PANEL- EM VENT PIPE- A-I PARTIAL LAYOUT RIDGE IS'-I e" INVERTER- 7- PANEL PHOTOVOLTAIC- A-2 ROOF ACCESS PLAN PHOTOVOLTAIC �p FUSED-SERVICE RATED DISCO- E_I 0 74b ELECTRICAL ONE UNE MODULE AC DISCONNECT- A��FfSSIONA����\ DIAGRAM �, �� .� � SUPPLY SIDE CONNECTION— 5T L-I LABELING SCHEMATIC DC vc EXTERIORCOMBINER BOX-a FISHER ENGINEERING SERVICES,PG —I PHOTOS WILLIAM G FISHER,P E. ROOF 6 — IST FLOOR LOCATION— �5i> P O BOX 30 OAKDALE N Y 11169 RAIL E BASEMENT LOCATION-�> UCENSE NO 814659/631-186 4419 RAFTER r z"x 8" /16"o-c s GARAGE LOCATION- w> � S��ci�n MULTIPLE ROOF$STRUCTURE , �, m +i Sclnres:shc6ia Sa I l'-2" SOFFIT ROOF"1'2'$3" ACTUAL SPAN ROOF I— SUNATION SOLAR SYSTEMS III RAFTER/SPACING 2"X 8"/I6"O C EXTERIOR WALL RONKONKOMA NY 11119 ACTUAL SPA"IT-2" _ -f ® i , ROOF SECTION(TVP)-ROOF"1,2,$3' SHEATHING PLYWOOD SCALE N T S N5TAl I E INSTALLER COLLAR TIES N/A NUMBER TYPE/LAYERS ARCH ASPHALT II _ - CUSTOMER INFO ROOF"6" MARINAKIS RESIDENCE RAFTER/SPACING 2"X 6"I Ib"OC e ACTUAL SPAN II'-1" RIDGE 12-9 5" RAF= - ROOF 5 _ 5 5TAR RD EAST2MARION II I s 9 SHEATHING PLYWOOD SSPAIN `' JOB NUMBER COLLAR TIES N/A - "� •^ 152 y _ E., V TYPE/LAYERS ARCH ASPHALT I I - DATE Q - 5.14 ROOF 3 , JOB NOTES JOB HARDWARE / QTY. RAFTERRAIL ' N/A OPTIMIZER KITS 55 END CLAMPS 52 2"X 6" 122"RAIL N/A L-FEET 96 ROOF 4 168" RAIL 35 LUGS 13 _ 90FFlT RAIL SPLICES-22 8"X100'SCREEN-4 - �; �:` FULL HOUSE ROOF PLAN MIEXTERIOR WALL 'gyp SCALE' N.T.S. D CLAMPS 84 U-ANCHORS N/A f� - ROOF SECTION(TYP)-ROOF"6" SCALE N T S. FASTENER REQUIREMENTS BUILDING REVIEW NOTE NOTES l TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE 1. AN 18"WIDE CLEARING(FREE OF SOLAR ::- TOTAL ARRAY AREA=1,012 5F ENCLOSED DOCUMENT FOR MINIMUM ACCEPTABLE WIND LOAD ASCE 10(SEE CALCULATIONS, THIS SHEET)415 EQUIPMENT)SHALL BE PROVIDED ALONG AT PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS LEAST ONE SIDE OF THE ROOF RIDGE ON THE PSF MAX SPECIFIED IN THE BUILDING AND/OR RESIDENTIAL SAME SIDE AS THE SOLAR EQUIPMENT OR ON TOTAL UPLIFT=41.5 PSF X 1,012 SF =41,998 LBS CODE OF THE STATE OF NEW YORK. THIS REVIEW ANOTHER SIDE OF THE RIDGE THAT DOES NOT ADDITIONAL MATERIALS MODEL PANASONIC vBHN330SA16 330WATT EA FASTENER' DOES NOT GUARANTEE COMPLIANCE WITH THAT CODE HAVE SOLAR EQUIPMENT ON IT IN ADDITION,AN ' "/A 62 6"L X 41.5"W X 1.38"D, 18.05 FT THAT RESPONSIBILITY IS GUARANTEED UNDER THE IS" WIDE PATHWAY(FREE OF SOLAR EQUIPMENT) )01/201 1 LAG SCREW SPEC 203 2,8104 (FLAT WASHERS REQUIRED TO BE USED WITH LAG SEAL AND SIGNATURE OF THE NEW YORK STATE SHALL BE PROVIDED FROM AT LEAST ONE EAVE 40 81#/MODULE(2.3#/5FLICENSED DESIGN PROFESSIONAL OF RECORD THAT OR GUTTER CONNECTING TO THAT 18" ROOF MODULE (55))eih 0SAI6 BOLTS) SEAL AND SIGNATURE HAS BEEN INTERPRETED AS AN RIDGE CLEARING OPTIMIZER (55)P-400 LAG BOLT WITHDRAWAL VALUE;5/16" DIA,266 LB/IN X 2-INCH THREAD DEPTH= ATTESTATION THAT,TO THE BEST OF THE LICENSEE'S INVERTER ttl (I)SEII400A-Us 532LB CAP. EACH 2 ROOF SHALL HAVE NO MORE THAN A SINGLE STRINGING INV al >ZI(I x 15) )S (1 x O S U x 1e) BELIEF AND INFORMATION THE WORK IN DOCUMENT IS LAYER OF ROOF COVERING IN ADDITION TO THE MINIMUM NUMBER OF LAG BOLTS REQUIRED=41,998 LBS/532 LBS/LAG BOLT=19 ACCURATE SOLAR EQUIPMENT INVERTER#2 (1)SE50eew-US TOTAL RAIL FEET=490'-0" RAIL FT/19 BOLTS=6'-2" • CONFORMS WITH GOVERNING CODES APPLICABLE DRAWN BY STRINGING INV a2 K-(1 11S, MAXIMUM SPAN BETWEEN MOUNTING FEET BOLTS"X" USE 5'-4" MAX AT THE TIME OF THE SUBMISSION 3 INSTALLATION-OF SOLAR EQUIPMENT SHALL BE CHRISTIAN BLANK RACKING sNAP'N'RAGK-SERIES 100 UL 2703 . CONFORMS WITH REASONABLE STANDARDS OF FLUSH-MOUNTED,PARALLEL TO'AND NO MORE PACKAGE STANDARD THAN fo-INCHES ABOVE THE SURFACE OF THE REVISION SYSTEM RATING(OC) Is Ise KW PRACTICE AND WITH VIEW TO THE SAFEGUARDING ROOF EST PRODUCTION CAG 11 4 WEIGHT OF THE INSTALLED SYSTEM SHALL NOT ,536 KWH/YR OF LIFE, HEALTH, PROPERTY AND PUBLIC DATE DESIGNER NOTE EST-PRODUCTION SOURCE SUNATION PRODUCTION CALCULATOR WELFARE IS THE RESPONSIBILITY OF THE LICENSEE EXCEED MORE THAN 5-PSF FOR 5141a DAVE MEJI4 FINAL SPECIAL ATTACHMENTS N/A - PHOTOVOLTAICS AND NO MORE THAN 6-PSF FOR xxxXxx N/A ,NIA STRUCTURAL STATEMENT RESIDENTIAL SOLAR HOT WATER SYSTEMS xxxxxx N/A NIA 5 ANY PLUMBING VENTS ARE NOT TO BE CUT OR CLIMATIC � GEOGRAPHIC DESIGN CRITERIA - TABLE 8301.20) THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT COVERED FOR SOLAR EQUIPMENT INSTALLATION xxxxxX N/A NIA THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC ANY RELOCATION OR MODIFICATION OF THE VENT WIND DESIGN SUBJECT TO DAMAGE MODULE SYSTEM INCLUDING UPLIFT$SHEAR THE REQUIRES A PLUMBING PERMIT AND INSPECTION SCALE EXISTING RAFTER SIZES$ DIMENSIONS CONFORM TO t N.T.S. SPECIAL WIND WIND SEISMIC CLIMATE FROST WINTER ICE AIR MEAN IRC-2015 TABLE 8802 5(1)-RAFTER SPANS GROUND SPEED TOPOGRAPHIC WIND EXPOSURE BORNE DESIGN ZONE WEATHERING LINE TERMITE DESIGN BARRIER FLOOD FREEZING ANNUAL TITLE SITE PLAN SNOW LOAD (MPH) EFFECTS REGION CATEGORY DEBRIS CATEGORY DEPTH TEMP UNDERLA7MENT HAZARD INDEX TEMP THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE ZONE REQUIRED MOUNTING BRACKETS AND HARDWARE MEET OR MINIMUM DESIGN STANDARDS FOR BUILDING AND -MOD SEE EXCEED NEW YORK STATE CODE REQUIREMENTS FOR OTHER STRUCTURES OF THE ASCE 1-le, IRC 2015 2e PSF 13e 5 NO 5 2 G 4A SEVERE 3-e" HEAVY 15 DEG NA EXAMINER 599 sl THE DESIGN CRITERIA OF THE TOWN AND NEW,,YORK STATE UCS 2011 V � RIDGE OF NEIyN V N' (6)GARAGE 5 9 E Roor- G. 0 A 156'TRUE,21-TILT;9,25/12 PITCH V (15)MODULES ' 'fi ti NO 074659 Gam s .x FISHER ENGINEERING SERVICES,PG rca -WILIJAM G FISHER,PE 1'0 BOX 30 OAKDALE MY 111613 PITCH CHANGE v Q32 A33 UC SE NO 014659 1631-166-141 1 4y2" SUNation ROOF AREAJ GUTTER Se ar a5 4 111..'d by HOUSE SUNATION SOLAR SYSTEMS GUTTER Ili REMINGTON BLVD RONKONKOMA SLY Illl9 (1)UPPER IN N W A Roor A6 A5 A4 336'TRUE,IS'TILT,425/12 PITCH NYSERDA (23)MODULES INSTALLER RR NUMBERj „i', ,, 435ro BETWEEN ROWS MARINAK15 RESIDENCE CUSTOMER INFO SPACIN /Aksk'-\114�K�i' A A 3025 STAR RP EAST MARION II935 / A�:Ak A* A& N4& -,Aig -A� AJOB NUMBERA.— �\ DATE >-5NAI-NRACK ISTEM 4*1 PV (TYPICAL RAIL ACROSS B�.14 A , AA AA A 1,/ .A..ROW OF ARRAY) • TWO SHOWN FOR Av CLARITY) J05 NOTES I NIA V- XG RIDGE ////X PHOTOVOLTAIC- MODULE(TTP) 12 W vt' V4 *1 »t TwL ADDITIONAL MATERIALS 1Y I NIA i / GUTTER (2)UPPER 9 S E ROOF -16 Oc IEW TRUE,M*TILT,4 25/12 PITCH (11)MODULES DRAWN BY CHRISTIAN BLANK <41 REVISION VENT PI 21 4*RIDGE DATE DESIGNER NOTE 3• ck AIS 51418 [DAVE MEJIA FINAL PARTIAL HOUSE ROOF PLAN XXXXXX N/A NIA SCALE 3/16"=1'*" XXX<XX NIA NIA I XXXXXXI N/A I NIA GUTTER 1-6Y2' SCALE TITLE PARTIAL LAYOUT A16 4y;(3)LOWER 1119 UJ ROOF 246'TRUE,19°TILT..425/12 PITCH APPROVED BY W MODULES Aml OF NFA r DETACHED GARAGE J' oho° 074659 . F£SS 1ONa�- �: FISHER ENGINEERING SERVICES,P r- 4,M - WILLIAM G FISHER,P I- PO PO BOX 30 OAKDALE RY 111613 LICENSE NO 014659/6)I-186-4419 SuNbtlon SaG:r*s't sRm:ld ( Ffill SUNATION SOLAR SYSTEMS INV FS -- Ill REMINGTON BLVD SUB RONKONKOMA NY 11119 ROOF_6 FNYSERDA STALLER (EXT) ACCESS ROOF A ROOF SURFACE WHICH PROVIDES ACCESS TO-THE RIDGE OR PEAK OF AN ADJOINING ROOF SURFACE CONTAINING SOLAR PANELS,MODULES OR ARRAYS AND IS UMBER IN_v ^5 S UI RELATIVELY FREE OF VENTS,SKYLIGHTS AND OTHER OBSTRUCTIONS AND CUSTOMER INFO 2 DOES NOT CONTAIN SOLAR PANELS,MODULES OR ARRAYS,OR 15 A SINGLE RIDGE ROOF WHERE THE TOTAL EDGE WIDTH OF THE SOLAR PANELS,MODULES OR ARRAYS DOES ACCESS t_: ;:' CB) - NOT EXCEED 33 PERCENT OF THE RIDGE LENGTH MARINAKIS RESIDENCE R324.1 ACCESS AND PATHWAYS-ROOF ACCESS,PATHWAYS AND SPACING REQUIREMENTS FOR SOLAR PHOTOVOLTAIC SYSTEMS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS R324 11 THROUGH R324 T 6 EXGEPTIONCSk r,. 3025 STAR RD ,$ '� ,.�, - :. �y .�'?'", I ROOF ACCESS,PATHWAYS AND SPACING REQUIREMENTS NEED NOT BE PROVIDED WHERE AN ALTERNATIVE VENTILATION METHOD HAS BEEN PROVIDED,OR WHERE EAST MARION 11939 'RooF - VERTICAL VENTILATION TECHNIQUES WILL NOT BE EMPLOYED JOB NUMBER ACCESS - '.�36'-'- 2 DETACHED NON-HABITABLE GROUP U STRUCTURES ROOF I FRONT OF 14CUSE-FACING STREET.DRIVEWAY R3241 4 SINGLE RIDGE ROOFS-PANELS,MODULES OR ARRAYS INSTALLED ON ROOFS WITH A SINGLE RIDGE SHALL BE LOCATED IN A MANNER THAT PROVIDES TWO 36 ,82�/� INCH WIDE(914MM)ACCESS PATHWAYS EXTENDING FROM THE ROOF ACCESS POINT TO THE RIDGE ACCESS PATHWAYS ON OPPOSING ROOF SLOPES SHALL NOT BE ta LOCATED ALONG THE SAME PLANE AS THE TRUSS,RAFTER OR OTHER SUCH FRAMING SYSTEM THAT SUPPORTS THE PATHWAY DATE EONCSkI ROOFSOOFS WITH SLOPES OF 1 UNITS VERTICAL AND 12 UNITS HORIZONTAL(166 PERCENT)AND LESS2 STRUCTURES WHERE AN ACCESS ROOF FRONTS A STREET,DRIVEWAY OR OTHER AREA READILY ACCES15LE TO EMERGENCY RESPONDERS - 3 ONE ACCESS PATHWAY SHALL BE REQUIRED WHEN A ROOF SLOPE CONTAINING PANELS,MODULES OR ARRAYS IS LOCATED NOT MORE THAN 24 INCHES WOMM) NOTES - VERTICALLY FROM AN ADJOINING ROOF WHICH CONTAINS AN ACCESS ROOF I N/A -,BI-NOLLV IIIN3n R3241 6 ROOFS WITH VALLEYS-PANELS AND MODULES SHALL NOT BE LOCATED LESS THAN 18 INCHES(45l MM)FROM A VALLEY EXCEP710N(Sk vENTILATION-IS'- I ROOFS WITH SLOPES OF 2 UNITS VERTICAL AND 12 UNITS HORIZONTAL(I6 6 PERCENT)AND LESS "c— R324 T I ALLOWANCE FOR SMOKE VENTILATION OPERATIONS-PANELS AND MODULES SHALL NOT BE LOCATED LESS THAN IS INCHES(451 MM)FROM A RIDGE OR PEAK Y EXCEPTICN(S) �RooF' I WHERE AN ALTERNATIVE VENTILATION METHOD HAS BEEN PROVIDED OR WHERE VERTICAL VENTILATION METHODS WILL NOT BE EMPLOYED BETWEEN THE UPPER ACCESS MOST PORTION OF THE SOLAR PHOTOVOLTAIC SYSTEM AND THE ROOF RIDGE OR PEAK _ 2 DETACHED GARAGES OR ACCESSORY STRUCTURES ROOF 2 ROOF 5 ILI Q •t„= v f. C ``i..i W "}- ^q, ,ACCESS `'�ti ROOF .. DRAWN BY - _ DAVID MEJIA - ROOF 3 R` REVISION DATE DESIGNER NOTE XXXXXX N/A N/A XX.XXXX N/A N/A XXXXXX NIA N/A r ; XXXXXX N/A N/A ROOF 4 SCALE SVA A 5 N.T.S. E5 TITLE ROOF ACCESS PLAN A=2 i OF cAt UllUTY SERVICE r M 1 2 14 15 - PLAOUE ��O NO 074659 ���� PLAQUE SERVICE DISCONNECT • _ = SERVICE DISCONNECT 3 SUPPLY SIDE I OF 2 _ 2 OF 2 COIAIECTION SECOND DISCONNECT SOLAR EDGE 5EI149eA-U5 INVERTER (ACTIVATES RAPID LOCATED NEXT TO OPTIMIZER UNGROUNDED WITH 9NUTDOWtU METER PAN (TTP) RIMARY DISCONNECT noDULE YBOX INTEGRAL DC SAFETY SWITCH LOCATED IN MAN FISHER ENGINEERING SERVICES,P C (TYP) 126/249 VA C I-PH SERVICE PANEL 200A WILLIAM G FISHER,PE• _ MAX 4l 5 AMP STRING I • • • • • • • O MAIN P O BOX 30 OAKDALE PLY 11169 60A FLL310LE UCEN5E NO 014659/631-186-4419 PV MODULE I 3-POLE (TTP I SERVICE RATED DISCONNECT C r# STRING OF MN ISK AIC OCPD (15)PANASONIC VBF4N3365AI6 W/ - SUNation •^ s.t sl+.rc' GS)OP-400 CURRENT LIMITING OPTIMIZERS I 2 IN•SERIES CIRCUIT• 14 15 EXISTING SUNATION SOLAR SYSTEMS — FEEDER TO --- 2 5u0 PANEL - Ill REMINGTON BLVD DG AG RONKONKOMA NY 11'1113 INPUT OUTPUT 4 MAIN SERVICE NYSERDA STALLE PANEL INSTALLER STRING z - • • • • • • • I - - NUMBER CUSTOMER INFO STRING OF I — MARINAKIS RESIDENCE (15)PANASONC VB14N330SAI6 W/ BUILDING (15)OP-400 CURRENT LIMITING OPTIMIZERS I 2 IN SERIES CIRCUIT g 10 GROUNDING 3025 STAR RD ELECTRODE EAST MARION 11939 ` JOB NUMBER _ STRING 3 • • • • - DATE 5.14.18 .14.18 STRING OF _ NOTES (19)PANASONIC VBHN339SAI&W/ - I N/A (IO)OP-40&CURRENT LJMITING OPTIMIZERS Z FEEDER TAP- - IN SERIES CIRCUIT \ SE5000H-US INVERTER CONVERTIBLE UNGROUNDED WITH - MAIN WG ONLY 59A INTEGRAL DC SAFETY SWITCH MUST ADD ' 120/240 VAC I-PH lvel SBAMP MAIN MAIN 1 2 14 15 MAX 21 AMP BREAKER — c • • • • • • • _ = O bOA FUSIBLE . 3-POLE SERVICE RATED DISCONNECT -- - SOLAR EDGE --- --- / / / MN 22K AIG30A OPTMZER /�/ / Al GPO $ (TYP) MODULE J-BOXlei TTP) STRING i _ PV MODULE SUB PANEL trm) 5 DC AC 6 STRING of INPUT-�OUTPUT (15)PANASONIC VBHN3365A16 WI J (15)OP-400 CURRENT LIMITING OPTIMIZERS IN SERIES CIRCUIT CONDUIT AND CONDUCTOR SCHEDULE _ BUILDING TAG DESCRIPTION OR CONDUCTOR NUMBER OF CONDUIT CONDUIT RUN GROUNDING ELECTRODE CONDUCTOR TYPE GAUGE CONDUCTORS TYPE SIZE LENGTH I V WIRE - 10 4 LFMC 12S, 30, - GG 6 I LFMC 125" 30• ' V WIRE 10 4 ,� PVC,BCH 80 12r," I8' _ GC 6 I PVC BCH 80 1.25" 18, _ _ HWN-2 6 3 PvC BCH Be 125' 4• GC/GEC 6 I PVC BCH 80 t15" 4• 3 HWN-2 6 3 PVG BCH 80 125" e GG/GEC 6 I _ PVG BCH 80 125' 8" - 4 EC 6 I PVG BCH 80 050" 6 -DRAWN BY 5 v WIRE 10 4 LFMC/EMT 125" 20` DAVID MEJIA GG 6 1 LFMC/EMT 125" 20 SCALE 6 HWN-2 6 3 PVC BCH 80 125, 4 GC/GEC 6 I PVC BCH 80 1 25" 4• - �•�•�• 7 HWN-2 6 3 ` PVC BCH 80 125" b TITLE ONE-LINE DIAGRAM ' 2GC/GC IC -I EC 6 I ' PVSC80 125" 6 8 EC 6 I L1 PVC BCH Be 0 50" 6• _