HomeMy WebLinkAbout42731-Z �o�osuFFQlkcoGy Town of Southold 8/22/2018
o -
P.O.Box 1179
co 53095 Main Rd
Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 39860 Date: 8/22/2018
THIS CERTIFIES that the building SOLAR PANEL
Location of Property: 3025 Stars Rd, East Marion
SCTM#: 473889 Sec/Block/Lot: 22.-2-20.1
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
5/21/2018 pursuant to which Building Permit No. 42731 dated 5/29/2018
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
roof-mounted solar panels on existing sin leg family dwelling as applied for.
The certificate is issued to Martem Management Inc
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 42731 7/24/2018
PLUMBERS CERTIFICATION DATED
on
54tm�- /,I,/
Authorized Signature
0L I( TOWN OF SOUTHOLD
,,�� BUILDING DEPARTMENT
a
` TOWN CLERK'S OFFICE
o . SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 42731 Date: 5/29/2018
Permission is hereby granted to:
Martem Management Inc
664 85th St
Brooklyn, NY 11228
To: install roof-mounted solar panels on existing single-family dwelling as applied for.
At premises located at:
3025 Stars Rd, East Marion
SCTM # 473889
Sec/Block/Lot# 22.-2-20.1
Pursuant.to application dated 5/22/2018 and approved by the Building Inspector.
To expire on 11/28/2019.
Fees:
SOLAR PANELS $50.00
ELECTRIC $100.00
CO -ALTERATION TO DWELLING $50.00
Total: $200.00
Bui spector
Form No.6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I% lead.
5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied,the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy-New dwelling$50.00, Additions to dwelling$50.00, Alterations to dwelling$50.00,
Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building- $100.00
3. Copy of Certificate of Occupancy- $.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00
Date.
New Construction: Old or Pre-existing Building: (check one)
Location of Property: '90an eG25L Lvm
House No. Street Hamlet
Owner or Owners of Property: M ae�
Suffolk County Tax Map No 1000, Section Block Lot
Subdivision Filed Map. Lot:
Permit No. Date of Permit. Applicant:
Health Dept. Approval: Underwriters Approval:
Planning Board Approval: /
Request for: Temporary Certificate Final Certificate: � (check one)
Fee Submitted: $
t Si ature
ho,\\pF SOUTyoI
0
Town Hall Annex Telephone(631)765-1802
54375 Main Road Fax(631)765-9502
P.O.Box 1179 G Q
Southold,NY 11971-0959 �oly� dao roger.richert(-town.southoId.ny.us
�UNT`I,
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICIAL COMPLIANCE
SITE LOCATION
Issued To: Martem Management Inc. (Michael Marinakis)
Address: 3025 Stars Road city,East Marion st: New York zip: 11939
Building Permit#: 42731 Section: 22 Block: 2 Lot: '20.1
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: DBA: SUNation Solar Systems License No: 33412-ME
SITE DETAILS
Office Use Only
Residential X Indoor X Basement Service Only
Commerical Outdoor X 1st Floor Pool
New Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
INVENTORY
Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures
Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors
Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps
Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks
Disconnect Switches Twist Lock Exit Fixtures TVSS
Other Equipment: 18.150 W Roof Mounted Photovoltaic System to Include: 55- Panasonic 330 Panels,
1- SE 11400 Inverter and 1- SE 5000 Inverter, 2-A/C Disconnects.
Notes.
Inspector Signature: Date: July 24, 2018
0-Cert Electrical Compliance Form.xls
SO�TyOIo
io
TOWN OF SOUTHOLD BUILDING DEPT.
765-1602
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLEIG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE,SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
REMARKS:
t
-Z
DATE INSPECTOR'<F<N
Fisher Engineering Services, P.C.
PO Box 30' Oakdale • New York 11769
Phone: (63 1) 563-9028
June 15, 2018 D �cr5BV[2
D
Town of Southold Building Department AUG 1 5 2018
Post Installation Certification
BUILDING DEPT.
Subject: Engineer Statement for Solar Roof Installation TOWN OF SOUTHOLD
Residence: Marinakis—3025 Stars Road, East Marion
Permit No. 42731
Installation Inspection Date: 06-14-2018
The roof mounted photovoltaic system at the above referenced residence has been
generally observed to be installed properly in accordance with the approved plans and is
certified-by-Fisher Engineering Services, P.C. to be in compliance with the minimum
requirements of the Town,the 2017 NYS Uniform Code, 2017 NYS Uniform Code
Supplement, 2015 International Residential Code (2015 IRC), Long Island Unified Solar
Permit Imitative (LIUSPI), and National Electric Code 2014, and the provisions of ASCE
7-10.
NEw
Sincerely,
William G. Fisher, P.E.
Licensed Professional Engineer
' �f:tlij �c.•. .1-c a r" 1' ti.' iV` :L; 1r'. .S E1 .»'\i. !. - r� �- �', •t��.rwi - �..
Li- tits: t.7.:,9:'�}., i 'y � - �•{i e�+ -s(s�.ls 1, .�: �r,....-"}! s I
zi
Architectural Design•Residential•Light Commercial
Additions.-Extensions-Conversions
Construction Estimates/Oversight•Expediting•Inspections
FIELD INSPECTION REPORT DATE COMMENTS
FOUNDATION(1ST) H
--------------------------------------
'FOUNDATION (2ND)
CN O
a
ROUGH FRAMING& y
PLUMBING ,
INSULATION PER N.Y.
STATE ENERGY CODE•
FINAL
ADDITIONAL COMMENTS
ITA A ,7 str
z z
rn
G, r d
Mll
IAV
�l z°
e
b
H
TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following,before applying?
TOWN HALL Board of Health
SOUTHOLD,NY 11971 4 sets of Building Plans
TEL: (631)765-1802 Planning Board approval
FAX: (631)765-9502 �ri Survey
SoutholdTown.NorthFork.net PERMIT NO. Check
Septic Form
N.Y.S.D.E.C.
Trustees
C.O.Application
Flood Permit
Examined ,20_Lo Single&Separate
Storm-Water Assessment Form
Q Contact:
Approved dk 1. 201 Mail to:SUNation Solar Systems,Inc
Disapproved a/c t 171 Remington Boulevard,Ronkonkoma NY 11779
Phone:(631)750-9454
DBut dt pector
MAY APPLICATION FOR BUILDING PERMIT
Date ,201
INSTRUCTIONS
TOWN OF soumow
a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans,accurate plot plan to scale.Fee according to schedule.
b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas,and waterways.
c.The work covered by this application may not be commenced before issuance of Building Permit.
d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit
shall be kept on the premises available for inspection throughout the work.
` e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the
property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an
addition six months.Thereafter,a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or
Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The
applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit
authorized inspectors on premises and in building for necessary inspections.
(Signatu licant or name,if a rporation)
SUNahon Solar Systems,Inc 171 Remington Boulevard,Ronkonkoma NY 11779
(Mailing address of applicant)
State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder
SUNation Solar Systems,Inc-Contractor
Name of owner of premises e 1 Ma a nay' s
(As on the tax roll or latest deed)
If applicant is a corporation,signature of duly authorized officer
Scott Maskin-President
(Name and title of corporate officer)
Builders License No.44104-H
Plumbers License No. N/A
Electricians License No.33412-ME
Other Trade's License No.
1. Location of land on which proposed work will be done:
'�09!5 <-540C
House Number Street Hamlet
County Tax Map No. 1000 Section Block Lot p�.
Subdivision Filed Map No. Lot
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy Residence
b. , Intended use and occupancy Residence with addition of Solar Panels
3. Nature of work(check which applicable):New Building AdditionAlteration�
Repair Removal Demolition Other Work So ar Panus
(Description)
4. Estimated Cost(s 5 t, �" Fee $200 00
(To be paid on filing this application)
5. If dwelling,number of dwelling units Number of dwelling units on each floor
If garage, number of cars
6. If business,commercial or mixed occupancy,specify nature and extent of each type of use.
7. Dimensions of existing structures,if any: Front Rear Depth
Height Number of Stories
Dimensions of same structure with alterations or additions: Front Rear
Depth Height Number of Stories
8. Dimensions of entire new construction: Front Rear Depth
Height Number of Stories
9. Size of lot: Front Rear Depth
10. Date of Purchase Name of Former Owner
11. Zone or use district in which premises are situated
12. Does proposed construction violate any zoning law,ordinance or regulation? YES NO X
13. Will lot be re-graded? YES NO X Will excess fill be removed from premises?YES NO X
14. Names of Owner of premisesA(C.V&I WO(jyjILAddress 3XIS Y Pr1. OPhhoo e No. Rlc)--T
Name of Architect wllllam G Fisher Address PO Box 30•Oakdale,NY 11769 Phone No 631-786-4419
Name of Contractor suNanon solar Systems,Inc Address 171 Remington Boulevard,Ronkonkoma NYPhone No. 631-750-9454
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO X
*IF YES,SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? *YES NO X
*IF YES,D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey,to scale,with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey.
18.Are there any covenants and restrictions with respect to this property? * YES NO X
* IF YES,PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUNTY OF!)
Scott Maskin-President-SUNation Solar Systems,Inc being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)He is the Contractor
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be
performed in the manner set forth in the application filed therewith.
Sworn to before met is
l day of 20k_
JWm-&/M 'U n
NotaryPublic Si of AppI cant
VICTORIA M W4KER
NOTARY PUBLIC-STA E OF NEW YORK
No. 01WA6S19756
Qualified in SufYolk CoLrlfy
Mfr Commission Expires February 29+•2019
Scott A. Russell 01'0 SU 'r�� ST01KMWA ]F1E]K
SUPERVISOR MAN
SOUTHOLD TOWN HALL-P.O.Boz 1179
53095 Main Road-SOUTHOLD,NEW YORK 11971 g Town of Southold
CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET
( TO BE COMPLETED BY THE APPLICANT )
DO]ES TMS IPROXECT INVOLVE ANY OF THE ]EO]LWWIING:
Yes No (CHECK ALL THAT APPLY)
❑ . Clearing, grubbing, grading or stripping of land which affects more
than 5,000 square feet of ground surface.
❑ B. Excavation or filling involving more than 200 cubic yards of material
within any parcel or any contiguous area.
❑ . Site preparation on slopes which exceed 10 feet vertical rise to
100 feet of horizontal distance.
❑ D. Site preparation within 100 feet of wetlands, beach, bluff or coastal
erosion hazard area.
❑ . Site preparation within the one-hundred-year f loodplain as depicted
on FIRM Map of any watercourse.
❑ F. Installation of new or resurfaced impervious surfaces of 1,000 square
feet or more, unless prior approval of a Stormwater Management
Control Plan was received by the Town and the proposal includes
in-kind replacement of impervious surfaces.
If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name,
Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project.
If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan
and a completed Check List Form to the Building Department with your Building Permit Application.
APPLICANT (Property Owner,Design Professional.Age t,Contractor,O ier) S.C.T.M. #: 1000 Date.
District
NAME 1 — 0q OBJ' I
r i Section Block Lot
�tg°" ** "FOR BUILDING DEPARTMENT USE ONLY****
Contact Information
t
Reviewed By:
— — — — — — — — — — — — — — — —
Date: d
Property Address / Location of Construction Work: — — — — — — — — — — — — — — — — —
ElApproved for processing Building Permit.
Stormwater Management Control Plan Not Required.
Stormwater Management Control Plan is Required.
(Forward to Engineering Department for Review.)
FORM # SMCP-TOS MAY 2014
Town Hall Ami" Telephone(631)765-1802
54375 Main Road (631)765-05
roger.richert own.SoUt ofi
P.O.Box 1179 py.US
Southold,NY t 1971-0959
BUILDING DEPARTMENT
TOWN OF SOLTMOLD
APPLICATION FOR ELECTRICAL INSPECTION
REQUESTED BY: Gina Date: 4-26-2018
Company Name: SUNation Solar Systems, Inc.
Name: Scott Mtiskin
License No.: 33412-ME
Address: 171 Remington Blvd, Ronkonkoma, NY 11779
Phone No.: 631-750-9454
JOBSITE INFORMATION: (*Indicates required information)
*Name: Michael Marinakis
*Address: 3025 Star Road, East Marion, NY 11939
*Gross Street:
*Phone No.: 631-477-8652
Permit No,: a—)51
TaxVap District. 1000 , ection: 22 Block: 2 Lot: M1
*BRIEF DESCRIPTION OF WORK(Please Print Clearly) ' 18,150W Roof Mounted Solar PV System
Including: 55-Panasonic VBH N330SAl 6 PV Modules. 1-Solaredge S E I 140OA-US Inverter W/Disconnect and
I-Solaredge SE500OH-US Inverter W/Disconnect.
(Please Circle All That Apply)
1s job ready for inspection:
YES/ NO Rough In Final
*Do-you need a Temp Certcate:
YES/ NO
Temp Information(if needed)
*Service Size: I Phase 3Phase 100 150 200 300 :350 400 Other
*New Service: Re-connect Underground Number of Meters Change of Service Overhead
Additional Information: RAYMENT'DUE WITH APPLICATION
B2-Request for Inipection Fonn
pf SO!/l�Ql
Town Hall Annex Telephone(631)765-1802
54375 Main Road y Fax(631)765-9502
P.O.Box 1179 G • Q
Southold,NY 11971-0959 'Q
BUILDING DEPARTMENT
July 30, 2018 TOWN OF SOUTHOLD
SuNation Solar
171 Remington Blvd
Ronkonkoma NY 11779
Re: Martem Management, 3025 Stars Rd, East Marion & Reventlow, 1000
Stillwater Ave, Cutchogue
TO WHOM IT MAY CONCERN:
The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy:
NOTE: Post installation engineer's certification letter required stating the panels were installed per
NYS Building Code
Electrical Underwriters Certificate
A fee of$50.00.
Final Health Department Approval.
Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84)
Trustees Certificate of Compliance. (Town Trustees#765-1892)
Final Planning Board Approval. (Planning#765-1938)
Final Fire Inspection from Fire Marshall.
Final Landmark Preservation approval.
Final inspection by Building Dept.
Final Storm Water Runoff Approval from Town Engineer
BUILDING PERMIT — 42731 & 42764- Solar Panels
SUFFOLK COUNTY DEPT OF LABOR,
I LICENSING&CONSUMER AFFAIRS
MASTER i
ELECTRICIAN
SCOTT A MASKIN
This cerf1 s that the' SUSVESSNAMr;
bearer is duly SUNATION SOLAR SYSTEMS INC
licensed by the
County Of Suffolk Number an.
33412-ME 06/24/2003
Oormiasbner MMOATION GATE
0610V2019
New York State Insurance Fund
Workers'Compensation&Disability Benefits Specialists Since 1914
199 CHURCH STREET,NEW YORK,N Y.10007-1100
CERTIFICATE OF WORKERS' COMPENSATION INSURANCE
Rol' rr �
^AAAA 753118816 "
SUNATION ROOFING SERVICES INC
171 REMINGTON BOULEVARD "a
RONKONKOMA NY 11779
SCAN TO VALIDATE
AND SUBSCRIBE `
POLICYHOLDER CERTIFICATE HOLDER
SUNATION'SOLAR SYSTEMS INC TOWN OF SOUTHOLD
171 REMINGTON BOULEVARD 54375 ROUTE 25
RONKONKOMA NY 11779 SOUTHOLD NY 11971
POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE
22160 670-2 617762 01/01/2018 TO 01/01/2019 5/21/2018
THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE
FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR
WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL
OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS
OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY.
IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS,
OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW
YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS.
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE
COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER
THE COVERAGE AFFORDED BY THE POLICY
NEW YORK STATE INSURANCE FUNC
DIRECTOR,INSURANCE FUND UNDERWRITING
VALIDATION NUMBER:539976195
Lvn�
APPROVED AS NOTED
DATE:"5 o B.P.' _'U-27sV. RM WATER RUNOFF
RETAIN STI
FEE: - ��� � BY: - `� PURSUANT TO CHAPTER 236
NOTIFY BUILDING DEPARTMENT,k AT--
76.5 4802 8 AM TO 4 PM FOR THE OF THE TOWN CODE.
FOLLOWING'INSPECTIONS:.
1.-FOUNDATIQ141 - TWO REQUIRED
,,,FOR POUF:CONCRETE
I -ROUGFI"w"AWING 8� PLUMBING
3,,INSULATI6h-
4. FINAL`.=
' Fisher Engineering Services, P.C.
PO Box 30 • Oakdale •New York 11769
Phone: (631) 563-9028
May 14 , 2018
Attention: Building Department
Subject: Engineer Statement for Solar Roof Installation
Marinakis Residence- 3025 Star Road, East Marion,NY
I have verified the adequacy and structural integrity of the existing roof rafters for
mounting the solar collector system (photovoltaic system) and its installation satisfies the
structural roof framing design load requirements of the 2015-International Residential
Code and the 2017-New York State Uniform Code Supplement, Long Island Unified Solar
Permit Imitative (LIUSPI), and National Electric Code 2014.
1 have reviewed and certify that the manufacturer's guidelines and equipment for the
photovoltaic system for the above residence meet the requirements for wind and snow
load and that the roof structure is adequate to carry the new loads imposed by the System.
For the installation of the solar mounting, the rails shall be securely anchored to the rafters
utilizing lag screws that have been designed for wind speed criteria of 130 mph and snow
ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and
geographic design criteria are not applicable to this solar installation.
The installation shall be in accordance with the minimum requirements certified by this
letter. The existing roof rafters are 2"x8"& 2'x6" on 16" c.c., with actual spans of 17'-2"
& 11'-2"with plywood roof decking and one roof shingle layer on the house as shown on
the drawings. There are no structural modifications planned or required for the existing
roof.
,1
I hope that this letter serves and meets with the approval of the Building Department.
Sincerely, pF NEW r0
Z,
William G. Fisher, E.
Licensed Professional Engineer
07
Architectural Design•Residential•Light Commercial
Additions•Extensions•Conversions
Construction Estimates/Oversight•Expediting•Inspections
HIT. Panasonic
Photovoltaic Module
Panasonic's unique hetero unction technology uses ultra-thin
amorphous silicon layers.These thin dual layers reduce losses,
resulting in higher energy output than conventional panels
Tab
Flaps,
n•type crystalline elllcan
ooublo-aided textured surf.. --
''-+ `NP'� '^ I•Yypo amorphous layer WThoaoamorphsusallloon Nysro
_ raduoae the minimbin 1-1 of
Amorphous lays, olaetrsne to minimum level.
Transparent electrodo(TCO)
Lattice type electrodes
UNa•Nln omorphoue a1llcon layer
Elootrodee
Advanced bifacial cell designed for increased energy output.
The cell utilizes sunlight reflected back from the rear side
material which captures more light and converted into energy.
Panasonic Conventional
R-
Back Sheet Beck-Sheet '
Our competitive advantages
High Efficiency at High Temperatures 25 Year Product and Performance Warranty"
As temperature increases, HIT°continues to Industry leading 25 year product workmanship
perform at high levels due to the industry leading and performance warranty is backed by a century
temperature coefficient of-0 258%/°C. No other old company- Panasonic Power output is
module even comes close to our temperature guaranteed to 90.76%after 25 years, far greater
characteristics That means more energy than other companies.
throughout the day.
Quality and Reliability Higher Efficiency 19.7%
Panasonic's vertical Integration, 20 years of Enables higher power output and greater energy
experience manufacturing HIT°and 20 internal yields HIT°provides maximum production for your
tests beyond those mandated by current limited roof space
standards provides extreme quality assurance.
®®® Low Degradation Unique water drainage
®®® HIT"N-type" cells result in extremely Low Light //® The water drainage system give rain,water and
Induced Degradation (LID) and zero Potential snow melt a place to go, reducing water stains and
Induced Degradation (PID)which supports soiling on the panel. Less dirt on the panel means
reliability and longevity.This technology reduces more sunlight getting through to generate power.
annual degradation to 0.26%compare to 0 70%
in conventional panels, guaranteeing more power
for the long haul
HIT®Is a registered trademark of Panasonic Group
HIT Panasonic
Photovoltaic ModuleLL
\_CCl`1`J-od\9lT
ELECTRICAL SPECIFICATIONS PERFORMANCE WARRANTY
100%
97%
Rated Power(Pmaxll 330W 325W 9s%
Maximum Power Voltage(Vpm) 58 OV 57 6V 9076%
Maximum Power Current(Ipml 5.70A 5 65A
_ r2P
° 2ower
Open Circuit Voltage(Vocl 69.7V 69.6V ss% 25 y....
Short Circuit Current(lscl 6 07A 6 03A so% es%
Temperature Coefficient(Pmax) -0,258%/°C -0 258%/°C
-_ —_ - - — — - 75%
Temperature Coefficient(Voc) -0 16V/°C -0,16V/°C
Temperature Coefficient(lscl 3,34mA/°C 3,32mA/°C 70%o s 10 1s 20 25
NOCT 44,0°C 44.0°C ■Panasonic ■conventional
CEC PTC Rating 311,3W 306.5W
Ceti Efficiency 2209% 21.76% DIMENSIONS
Module Efficiency 19,7°/4 19,4% 511053] 38[351 203[516 51 _
11
Watts per Ft 2 18 3W 18 OW
l 'Maximum System Voltage 600V 600V - I
Series Fuse Rating 15A 15A
Warranted Tolerance(/+) +10%/-0%- +10%/-0%' A A'
^�
MECHANICAL SPECIFICATIONSModel r
I
t
O (D
Internal Bypass Diodes 4 Bypass Diodes
Module Area 18,02 Ft 2(1,67m21 I 397110091
T i
Weight 40 81 Lbs 118 5kgl
I
Dimensions LxWxH 62 6x41 50 4 in.(1590xlO53x35 mm) Ll
Cable Length+Male/-Female
40 2/40 2 in (1020/1020 mm) M0Y �ra0ans
Cable Size/Type No 12 AWG/PV Cable
Connector Type' Multi-Contact®Type IV[MC4TM) °J
----' '---- `� 0797(2025]0 L�994JH_Hj�j�
Static Wind/Snow Load 50 PSF(2400 Pal
Pallet Dimensions LXWXH 63,7x42 2x65.4 in 1260[321 1457[371
Quantity per Pallet/Pallet Weight 40 pcs /1719 Lbs [780 kgl Unit inches(mm) Section A—A' Section B—B'
Quantity per 40'Container 560 pcs
Quantity per 20'Contamer 240 pcs DEPENDENCE ON IRRADIANCE
700
100ow/rd
OPERATING CONDITIONS&SAFETY RATINGS 600Model —
VBHN330SA16.VBHN325SA16 500 80ow/ni
a
Operating Temperature -40°F to 185°F I-40°C to 85°Cl � 400
Hail Safety Impact Velocity 1"hailstone(25mm)at 52 mph(23m/s) `
300 aooW/ni
Safety&Rating Certifications UL 1703,cUL,CEC
- - - 200
UL 1703 Fire Classification Type 2 I200W/rd
Limited Warranty 25"Yrs Workmanship and Power Output(Linear).". 100
000
NOTE Standard Test Conditions Air mass 1 5,irradiance=1000W/m2,telt temp 25°C 0 10 20 30 40 50 60 70 80
'Maximum power at delivery For guarantee conditions,please check our guarantee document Voltage IV)
"Installahon need to be registered through ourwebsne www nanasonrcusahitwarranty corn within 60 days Reference data for model VBHN3305A16
in order to receive twenty-five 1251 year Product workmanship Otherwise,Product Workmanship will be (Cell temperature 25°CI
only fifteen(15)years
•"Istyear 97%,after 2nd year 026%annual degradation toyear 25 A CAUTI0NIPIeasereadtheinstallationmanualcarefu[lybefore usingtheprod ucts
'STC Cell temp 25°C,AM 5,1000w/m' Used electrical and electronic products must not be mixed with general household waste For proper treatment,
2 Safety locking clip(PV-SSH4)is not supplied with the module recovery and recycling of old products,please take them to applicable collection points in accordance with
NOTE.Specifications and information above may change without notice your national legislation
1
solar=a@
SolarEdge Power Optimizer
Module Add-On For North America
OP250-LV/ OP300-MV/ OP-400-MV/ OP400-EV
vi
RsRF,�_
^
W xb�n�t-
�,,yvk�`
f,;t"°'." rx.�., � .p 'L "V I 1 J _. l ^{�_�•.`�s �Ak�aY '�{ .
Al
�.�i�'F,r rdYa i- '4'� ,tt:eA :i-.: yp �"� .lti! _ •-ffd:. �i�+fi.'S_ x` "r. x
,04 ' to
ONE
1 141
F."' :rQ'i- FL,:.«�`- '•r4• - R�r .�.,.r..,- :C:`. i F '° «�4.'A i� ,h 6e..,:�' - -
- _ -.}� _ r+ip'- - "a`:` I?°.�i"�_. K�,`S iT.:"s'?.<'.''w,' .... .:'�.s`S. .iN'✓t .�,• -
- 4�• _ _ i'L� ."f u rt 54 a P�.�.. Y4' a+:sin.=.>n
o>�nrer o
� tir>r `
I? �za#ion
.�. odute=ievel��
to -
^ p
SuperiorJcfictency{99:S%j
Mtigates.ati types of module mismatch losses,,fr_orn manufacturing tofeiance-to.partial-shading;
Fle%fe sysiem:design foi r»aximum space uti f'
nation
ir tNext-generation maintenance'W!6 module-16e1 monitorin
_=Module=level woitagq sfiutdoii✓n for installer anii'firefigtitersafety =
USA - GERMANY ITALY •- FRANCE JAPAN CHINA ISRAEL - AUSTRALIA WWW.SOlaredge.us
sola ®larEdge ®wer Optimizer
Module Add-On for North America
0P250-0V/ OP3004AV/ OP400-MV/ OP400-EV
OP250-LV OP303-MV ;_OP400_MV -I- OP400-EV ,_--__
INPUT
Rated Input DC Power* 250 300 400 400 W
Absolute Maximum Input Voltage(Voc) 55 75 75 ! 125 Vdc
MPPT Operating Range 5-55 5-75 5-75 15-125 Vdc
Maximum Short Circuit Current(Isc)of connected PV 10 10 10 7 Adc
Module
Maximum DC Input Current 12.5 12.5 12.5 8.75 Adc
Maximum Efficiency 99.5 %
Weighted Efficiency 98.8 /a
Overvoltage Category
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER)
Maximum Output Current 15 Adc
Operating Output Voltage — 5-60 y -Y4 Vdc —
OUTPUT DURING STANDBV(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF)
Safety Output Voltage per Power Optimizer 1 j Vdc
STANDARD COMPLIANCE - —
EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3
Safety IEC62109-1(class 11 safety),UL1741
Material UL-94(5-VA),UV Resistant
RoHS _ j -- Yes
INSTALLATION SPECIFICATIONS_ _
Maximum Allowed System Voltage 1000 Vdc
... ... . . 1. 1..... ......... .. . .. .... ............,<. .... ... ........ .. .. ......... . _....
Dimensions(WxLxH) 143x210x45/5.63x8.26x1.75 mm/in
l. ;
Weight 450/1.0 gr/Ib
input Connector - - -- -- - ----- -- = - - - ---- MC -/Tyco-/-H+S/Amphenol---H4 -- - -
. ... ., .. ;...,... .,.
Output Wire Type k Double insulated;6mmz;MC4
.... I
Output Wire Length 0.95/3.0 0.95/3.0 1.2/3.9 I 1.6/525_.,i m/ft
Operating Temperature Range -40-+65/-40;+150 •C/'F
Protection Rating IP65/NEMA4
Relative Humidity 0-100 %
Rated STC power of the module Module of up to+5Y power tolerance allowed.
PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V
INVERTER
Minimum String Length(Power Optimizers) 81 8 18
Maximum String Length(Power Optimizers) 25 25 50
Maximum Power per String 5250 6000 12750 W
Parallel Strings of Different Lengths or Orientations Yes
' -��'
R19
SOLAR SYSTEMS
m v d►[•3 � ?ar:rtnq /0U( wc+rld
1217 Montauk Highway,Oakdale,NY 11769
v ., a'` r •za _ .`a• a, : s s 631-750-9454
.+!-. - i- , r B.r S•. Yb a,• www.sunationsolarsystems.com A
�e'a�"s:., �+"�',•``" ''.fit '�y "�'--+,_ '^.�': � ""s; �s= �'
�Y
raq fur w'Yn,l� '>{:�^`..''''_. '�'- •„�.,, € m'e.'.r., .,'t•'-��'��
-r;tti+c?:mr"...,•, •._„ray..'a�k�'at'.'�ay.'4xiY .,5i"�,;>':'�,.�,i.
;.,
"+t. 't'�✓-'ai1 Pk, �•g' 'y w4,�"f"' np S�"`t'` #.s
,,�; a'��.,=',.-4.� }=a3vva,'Y,Pn'wS;,•;,.a'i$x.-, .r"�6:c �"�: 'Mrw''i
,�. -fi �„ tib, ,�`:a�M '��&.s•�:aK.y>:,..., .:Ca ,. .
11 E19
S ola
S®IarEdge Single Phase Inverters *
For North America
`�"�";'R"d.'rid.4..] •girLa X„v' .`?,t ,e. `s X t.w: 9-. <.p%y",''{
SE3000A-US/ SE3800A-US/ SE5000A-US/ SE6000A-US :`"v,
SE7600A-US / SE10000A-US/ SE11400A-US 1 , y
�L'r;-"e
f �x s5--`�.�•,.".•�>^�'tri;,,'-a; hr... ,�~ ,y� �.e
F71
,:.w'
'� m-�h - :"}a 9. -..,. Z:`✓.�.3'_w- ..�m'»y.3°"..:�_' �_�i�yu4'kA1,:'.�"'.
m J 'IS
y Ra 2T.�t a <eC„�.'�+dc +�h..�:.'$d::.."'b.4 '•�' �''�`" r f'r!�' �'`��`, MX rt a{..�4'��' 9 vr'1 '�,. ,,Y ,�"X j`
, .3 �a 1, .�Y�'a' ;-'d°' ''� '�i d4 -§ ?Y"^-,�'.« g�•t..." `C'% :: 9"_
._ ':tib,,. ,�+�..?-. •�, • ,,.,�,',.,,,;s"�;',;:''+?''a.;.;v,,.: .,.
:,a .,a..,. P�:a"cf—;¢.,P: g.1. .%',3. 'v r' ,.k:r- €...,�.A.N•� ��:"' v,,z:�r ,�X $^� "Ns:. e
' -� ��F3S, _ .r 'fV'�. , ��.:t , .}"r1`'.,� �t t •vx.,'1b��e ..T'"'i' ^6 1 Z~ p., �•�ren' �t.
r' e .A-v ^;i?o, b rti •�-a.;'��tr'e,��&:_`_.��.r,«:�,a :`+�:o..,.rs'`vo
i .5 + }'�-, +a.u}, y���.iy' a.ate,''-`, $i• .;� '"'.{,new'' "-'§°
,�' ,,,, ,
� " ^ $° i^aY•��'"M. �e~�rW>(N-'^":'✓��
{ .. � ,,�# ins '�y°'�'A r�..�^.,i�a;,;�''s�,^'` ,'; 'k.ti i>' 'r��3'1`„''.',':.�,v. '..`" 'x r. �s:5,>Y`,e^ ,',`�J" a':,t"*ap:•.
dN;:2-�'�t�X<'
r - '•'^ce +r,3't»'"` ."mP i,'f'.. �4'._,.i'+ .Wi';•,.A,c.°:._.,..'-"3.'„1 'v', aY{ +'4 ^,ate
s<��p.�t�,i.�!yi,�:
er� cU' `a' "Qw 4"ti"�'`o"- r• .yr'aRY..? i°y;- :',: -' � 4aw
,�>,,,� '�P"' §Nw,�:;^s'S�>�'"R',,",�:'�'i'-',yr',a.' a'!,.v �,;.•' ,;,�, 'R: �,.� i.�".r,.^ :�:'k. `i-.;.f>, .''f� '�ti'i',�;:,,.
;' ;"t'*' .'v«.a k•s , ." •t, r .�,es a' ;e.'r:< ,>�'<. : .i a`
•ti "'£' - ' '�•. � ' .<u�gry �'"'.� "±..5 ta�,�< '�',";,**boa'
.. ! "{ - -'. �.- 'a. .;,w �k.'z"-'^ ••.,�.;.�=•fir c?.a>.�.."- .Y".%°.,;,� ,.�;>z� • � -, 'z+.��'"�-r.k�a<. �'b,,,'' �'s*,.���;''+'
' �,ng g ^';,-"P„� sr,.<'' �j:' '�';s;.-'a`y."�<,S'', �,:tl w:2:,e,}6,i•s•.. d- n,'��;..
{ W'v'#,'{y:tgryti„� l"''.-3 @'�'✓.E Cr
"U
' e�,. :yi.y,a, ,'d"^:;.';d, c. �}' ,�.• .. s6i+ irr"•a a�
«�Q✓-,,
7,
�'�;�..�
u ",'_��:§ x `+'i�`�:,,�"C• '^ 5t..•`'��'»'o-'-,.'f F•<^.�-ga;•,3,�,Y �ra•. •f,=. t��.a .v,z.:a"&a,..`�.'
q "&
' .�Ps}•h:�w `.Fiu 7 Y ,dx-.ua, k'„ ,Jr.•'r:' ,,
=•i ' yP}id'.'� $"^ yn' ,1;'p"
'�g,;�
T6W'A'.'-
r
�, � •� �f^,t'". w;.S:°c y„.r:,�a as'"�'r�'�w-'r,�'��."�v i^;L�,atv:''�'_ 'p 6.;,.s'•.;i-"",<"�,'i":,�,1 �c K°"s^^ia"�,. �« �4:.°-...s..,,p-.
' ,� �!,e �;'. � i „`' r" �tl -. :,e'rk'.,,1• $".``*,;,a"SgrF .�?:s'::•�� ;�.�y,��}..y � "u �?..:,5"�'$d,:J^$':
1 �,a.,:«. 'a`»w'"4�•: 'a..�;,s',4" `�,",,, .}-'4`a�,r,,.... '" 'a:`.wa{', w�w}^*" �Q:;+,".
•
' „� - Y, '���#.'«,% a-�;;�-`' ���I.._3,� ' ,�g''.;?:%s,::.,�'a•'�',c='r;"'" �''-s�": �� a'in, � �, 'ar°"^'r�,�rn«,.,- a;:
( .. a 4 :'>< e,s.._ __.•... ,:
(i}=. Thesbest cbolce f6e S`O-a.IrEd a enabled sy. tei ms
lhtegrated'arc fault,protection(Type1)for NEC.2011-690.11 compliance(part numbers ending in
Superior,,iAciency{98%) j
l ' ^,Small,lightweight and easy to.install on.provided bracket"
�.
.Built-in module-level monitoring
Internet connection through'Ethernet or Wireless I
, 3
Outdoor and indoor,installation
Fixed voltage inverter,DC/AC conversion only,
Pre=assembled AC/DC Safety Switch.for faster installation
USA GERMANY ITALY FRANCE - JAPAN - CHINA - ISRAEL AUSTRALIA www.solaredge.us
i
s® ar' � oo
Single RhaSe Inverters for North America
SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/
SE760OA-US/SEt0000A-US/SEl140OA-US
SE3000A-US SE3800A-US SESOOOA US SE6000A-US SE760OA-US I SE10000A-US I SE1140OA-US
OUTPUT
Nominal AC Power Output 3300 3840 5200 @ 208V 6000 7680 9980 @ 208V 11520 VA
........................................... ................ . 5520 @240V 10080 @240V
.............. .......... ...... ................ ........ ....... .................. .................. ...........
Max.AC Power Output 3650 4150 5600 @ 208V 6000 8350 10800 @ 208V 12000 VA
6000 @240V 10950 @240V
......................................... ................ ............... ................. ................ ................ ...... ........... .................. ...........
AC Output Voltage Min-Nom-Max
.................... ............... ............... ................. ................ ................ ........ ......... .................. ...........
AC Output Voltage Min-Nom.-Max* ✓ ✓
211-240-264 Vac
..................................... .. ................ ............... ................. ................ ............ ... .................. .................. ...........
AC Frequency MinAom:Max* 59 3-60-60 5(with HI country setting 57-60-60 5) Hz
25 @ 208V 48 @ 208V
. .... .... ....... ........
Max Continuous Output Current 14 16 25 32 48 A
23 @ 240V 42 @ 240V
..... ......... ......... ......... .... .... ......... ............... . ............ ................ ........... ......... ........ ......... . .......
GFDI 1 A
.................................. ................. .......................... ...................... ..................................................... ...........
Utility Monitoring,Islanding
Protection,Country Configurable Yes
Thresholds
INPUT
Recommended Max DC Power** 4100 4800 6500 7500 9600 12400 14400 W
(STC) ..... ............... ................. ................ ................ .................. .................. ...........
. ............................. .
Transformer-less,Ungrounded Yes
Max Input Voltage 500 Vdc
........................................... ................
Nom DC Input Voltage 325 @ 208V/350 @ 240V Vdc
Max.Input Current*** 11.......I......13......�...17 @ 240V..�.......18....... ......23. ...... .30.5 @2040V..�.......35........ ...Adc....
........ ..................................
Max.Input Short Circuit Current 30 45 Adc
................................ . ... ............. . ................ ........
Reverse-Polarit Protection Yes
....y................... .... ........ ............................. ......... ........................................
Ground-Fault Isolation Detection f 600knSensitivity
Maximum Inverter Efficiency 97.7 . 9........ .. 98 3 98.3...... ......98...... ..... 98 98
CEC Weighted Efficiency 97.5 98 97 5 @ 208V975 975 97 @ 208V 975 %
98 @ 240V 97.5 @ 240V
.... ....................... ............ ................ ............... ................. ................ ................ .................. .................. ...........
.
Nighttime Power Consumption <2.5 <4 W
ADDITIONAL FEATURES
Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional)
STANDARD COMPLIANCE
Safety UL1741,UL16996(Part numbers ending in":U'.),UL1998,CSA 22 2
........................ ...........
Grid Connecfion Standards IEEE1547
.... .................................... .....................
.. .... ........................................... ...... ........ ...........
Emissions FCC part15 class B
INSTALLATION SPECIFICATIONS
AC output conduit size/AWG range 3/4"minimum/24-6 AWG 3/4"minimum/8-3 AWG
................................... ............ ...................................................... ...........
DC input conduit size/#of strings/ 3/4"minimum/1-2 strings/24-6 AWG 3/4"minimum/1-2 strings/14-6 AWG
AWGrange..............I.............. ................................ . .
.....................7. . ........ ................. .............. ..................... ...........
Dimensions with AC/DC Safety 305x125x7/ 30.5x12.5x5
./ 30.5x12.5x10.5/775x315x260 n/
Switch(HxWxD� 775 x 315 x 172 775 x 315 x 191 mm
.................. ........................ . ..............................................
Weight with AC/DC Safety Switch
512/23 2 547/24.7 88 4/401 Ib/kg
............... ... .................
Coohng Natural Convection Fans(user replaceable)
........................................... .............. .. ......... .. ... ............................... ................. .................................... ...........
Noise <25 <50 dBA
Min.-Max Operating Temperature -13 to+140/ 25 to+60(CAN version****-40 to+60) 'F/'C
Ranke................................I.. .
......................................................................................................................... ...........
ProtectionRating ......................................................NEMA 3R........................................................ ...........
*For other regional settings please contact SolarEdge support
**Limited to 125%for locations where the yearly average high temperature is above 779F/252C and to 135%for locations where it is below 779F/259C
For detailed information,refer to htto//www solaredee us/files/Ofs/mverter do oversizme ewde odf
***A higher current source may be used,the inverter will limit its input current to the values stated
*•**CAN P/Ns are eligible for the Ontario FIT and microFIT(microFIT exc SE11400A-US-CAN)
-;a '^ _ -" w;ti, .'7' 3.""^'*', aa • ^r.' i�'n.''f°�'a:"'fi.`P�zY'^^�,a,, •, ,: • a �- "" t, ,�;.
9. nq—.`3�,y ♦*»1 +, ._ai.. if _ "' a.,
gmmv
SOLAR SYSTEM S
d®r9
t_ g �� �N4 �r„=•e�pys� ,.2 �� � � .. ,y, Powering your world
631-750-9454
sunationsolarsystems.com "
5''rfa'6 .'�� P "^ .17',?.}. '�3ar ate' g'"i•, `"`e"'�.,,».V^:. �<
Solar=o@
y
S®IarEdge Single Phase Inverterseo
for North America
SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US /
SE760OH-US
_ i2��j•m4 �`
(o 'Joh �.k.
91n a �u� •4-,
4
._4_i6
„3t ,..
Optimized installation with H®-Wave technology
® ,Specifically designed.to work with power optimizer`s'
Record-breaking efficiency
l o
-;,Fixed voltage inverter.for longer strings `
Integrated Arc Fault protectiori and Rapid.Shutdown for NEC 2014 and 2017,per articler690.11 and 690'.12.
UL1741 SA certified,for CPUC Rule 21 grid compliance
Extremely small and easy"to install outdoorssor indoors
i High"reliability without any electrolytic capacitors9E!
Built-in module-level monitoring wave !
Optional:`116enue,grade data, ANSI C12.20 Class 0.5(0'.5%accuracy)
USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTH AFRICA-BULGARIA www.solaredge-us
so I a r = ® ® � Single Phase Inverters for North America "
SE3000H-US/SE380OH-US/SE5000H-US/SE6000H-US/SE760OH-US
SE3000H-US SE380OH-US SESOOOH-US SE6000H7US SE760OH-US
"OUTPUT
Rated AC Power Output 3000 3800 5000 6000 7600 VA
............................................................ ..........
Max.AC Power Output 3000 3800 5000 6000 7600 VA
...... ... .. ... .................................. . .................... .................... .................... .................... .................... .
AC Output. .Voltage. . Min:Nom-Max.(183-208-229) ✓ - Vac
...................M.i .... m.......................... ................... .................... .................... .................... .................... ....Va .....
AC Output Voltage Min:Nom.-Max.(211-240-264) ........✓,,,,,,,,, ,,,,,,,,,✓,._...,.. ,,,..,,,.✓...,,.,,. ....,,,,,✓......,,, ✓ Vac
......................................................... .
................ . .... ....
AC Frequency(Nominal] 59.3-60-60.5111 Hz
......................................................... .................... .................. .................... .................... .............
Maximum Continuous Output Current 208V 24 A
............................... .................... -.......... ....... .: ......
.. .... ..... ..... .. .. . .
Maximum Continuous Output Current 240V 12,5 16 21 25 32 A
............................................................ ......... .................... .............
GFDI Threshold 1 A
....................................... .................................................. .................................................. .............
Utility Monitoring,Islanding Protection,
Country Configurable Thresholds Yes
INPUT `
Maximum DC Power 4650 5900 7750 9300 11800 W
............................................................ .................... .................... .................... .................... .................... .............
Transformer-less,UngroundedYes
............................................................ . .................................................. .............
Maximum Input Voltage 480 Vdc
............................................................ . ............................. ....................
. .....
Nominal DC Input Voltage.............................. 380 4..0........ ....Vdc.....
................... . .................... .................... .
Maximum Input Current 208V 1Zi 13.5 Adc
........ ..........
Maximum Input Current 240V Rl 8.5 10.5 13.5 16.5 20 Adc
............................................................
Max.Input Short Circuit Current 45 Adc
............................................................ . .................................................. . ....
Reverse Polarity Protection .. Yes
............................................................ . .................................................. .............
Ground-Fault Isolation Detection 600kaSensitivity
............................................................ .................... .. . . .............
.......... .. ........................
Maximum Inverter Efficiency 99 99.2
.... .... .... ........ . . ...... .. .
CECWeighted Efficiency 99
.................................................... .... ............................. ................................................ .............
Nighttime Power Consumption <2.5 W
ADDITIONAL FEATURES,
Supported Communication Interfaces RS485.Ethernet,ZigBee(optional),Cellular(optional)
......................................... ...................................................................... .............
Revenue Grade Data,ANSI C12.20 Optional()
....................................... ............. ...... ...
.......... ........
_ .............
Rapid Shutdown NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect
STANDARD COMPLIANCE
Safety UL1741:UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07
............................................................ . ........................................ .................................... .............
Grid Connection StandardsIEEE1547,Rule 21,Rule 14(HI)
...........................I.......................... ........................................................................................................ .............
Emissions FCC Part 15 Class B
INSTALLATION SPECIFICATIONS, - I
AC Output Conduit Size/AWG Range 0.75:1,' Conduit/14-6 AWG
......................................................... ............................. ........................................................... .............
DC Input Conduit Size/#of Strings/AWG Range 0.75-1" Conduit/1-2 strings/146 AWG
.......................................... .. ...... ....... ................................ .............
Dimensions with Safety Switch(HXWXD) 17.7 x. x 6.8 /450 x 370 x 174 in/mm
............................................................ . . . .............
Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9
..................................................I. f. ................1.................. ....... ....
..... .. . ... .. . ...... .. .
Noise <25 < dBA
............................................................ ................................................................................... .............50....... .............
Natural
convection and
Cooling Natural Convection internal fan
(user
.......................................................... ...replaceable]... .............
Operating Temperature Range13 to+140/-25 to+600 (-40°F/-40°C option)15i °F/°C
g....................................... ........................................................................................................ .............
Protection Ratin NEMA 3R(Inverter with Safety Switch)
For other regional settings please contact SolarEdge support
1Z1 A higher current source may be used;the inverter will limit its input current to the values stated
Revenuegrade inverter P/N,SExxxxH-US000NNC2
Power de-ranng from 50'C
-40version P/N,SExxxxH-USOOONNU4
yry �;5' ,^§" '-i' t_�,r9�. Priv �s:-q -�^� -�. ^s.""-�" - •.r.•
i 4 i
th ca .. e e O e e
• •e. e e Technologies,enotice.
- SnapNrack- Series 100
Solar Mounting Solutions
Flashed L Foot
Y.
Reliable & Weatherproof
Roof Attachment
Cutting of shingles not
Preassembled, snap-in
required P hardware reduces installation-
time
Single tool installation, using Included in Series 100 UL
)j Y L
standard socket 2703 •
«� ..: - 1 '��' W..:.,$',• '�:q, .�-c, �.�o-e. -� ,� �> ,r"v r:'��, _ :y.i. � � -� .:;P,�"�i. `� ry���P.L�" #�„^* 'ti t"
v 8,
-R'
RESOURCES snapnrack.com/resources * .
DESIGN snapnrack.com/configurator
WHERE TO BUY snapnrack.com/where-to-buy
SnapNrack Series 100 Flashed L Foot Kit f -
is an industry-leading, weatherproof solution for attaching to composition shingle
roofs. The Flashed L Foot provides a fully flashed method for mounting the
SnapNrack Series 100 system. The combination of Series 100 and the Flashed L foot
is guaranteed to improve labor times and ensure the highest quality install possible.
Flashing
• Available in black galvanized steel or aluminum for
enhanced corrosion resistance
• L Foot is attaches to bottom edge of
flashing, removing the need for shingle
cutting
• Innovative stamped features provide -
increased rigidity
k."
,M1.
L Foot
• Engineered for maximum adjustability with the ability to orient in
any direction
• Vertical adjustability up to 3" using available spacers
f R'
L Foot Base
• Provides a long lasting watertight seal over the life of
the system that does not rely on rubber (elastomeric
seals) that will degrade over time
• Easily installs with off-the-shelf lag screws yr
Channel Nut
Provides snap-in installation to the rail channel with no
drilling required
Wide range of adjustability due to sliding ability in rail prior
to final tightening
e F
tuality. Performance . Innovation ,
SnapNrack solutions are focused on simplifying the installation experience through intuitive prod-
. • the best wire managementindustry.
SnapNrack
Solar Mounting Solutions
•
_
:'S'C':'OSW.it.'�Y.4{,`"`c'!'k!M^i•,t�3„ .h�',MotwnAkd.OiniSR°'=?e;.'ASS".:.>,ik�.INx",'IF:
4
„u "� rLL d'Y `�'•,,< !., �. "-;"'*��"$':�v.a+us^'" x...c .� ',so- �.s,'��y�„ �_,�,, �._ "s. c — '
-
Entire Mounting System from , Snap-in features make the
Single Manufacturer under 1 v`' install process intuitive and
Warranty fast
.Industry Leading Technical U The Most Comprehensive UL
Support Services for Every o 2703 Listing in the Industry
Customer
'1 +s • 1 a t .t,i" %• af•"�.; d" =r rCr..�f.F #•'�� � .�
�+ i'� ^a4 •''Y ,,.'� d�,. es d `s,� �� ,• .v a'� x+^� •n. r�' a,i� p' •„_,e n
r •fit' i �:■ itxt._. y'.' i "RUE
1 � 1
T: he SnapN rat, lkSleries,10G Rdof M 6 untSysteft '
' • ' . • • '
1
The top-of-the-line features of the SnapNrack mounting system reduce
install times and labor cost while eliminating the need for service calls
creating the lowest install lifecycle cost of any mounting system.
Wire Management
rA ; • Products such as the standard rail channel keep wires neatly
organized providing a clean finished look to every install
• Industry's largest offering of wire management accessories
include snap in junction box, 4-wire and trunk cable clamps,
as well as conduit clamps for both composition shingle and
tile roofs.
Undeniable Aesthetics
• Render the mounting system invisible by using Universal End Clamps that fasten
modules while remaining hidden underneath the array
• Array skirt provides a sleek look and
attractive design to the front of theWE
array
• Rail-based system provides rigid
structure tucked away underneath array with no
unsightly mounts at the top or bottom
u a 'i it YO Performance . - I'll Innovation ,
IT
products and the, best wire Manageme�nt in the' industry.
SnapNracki
�oll§rMoUhtin.g solutions
877-732-2860
ra . - -
• •
3
tVe
L �
W
System designed with Easier logistics through simple
maximum versatility for anybox packaging and no long rails
arrays including staggered rot
Simple design allows system to Drop-in features make the
be installed by single installer install process intuitive and fast
on the roof
"AS"SNIM 1 :' a�- A C',
'instaillex
• - • • - • •
Flash Track with Patented Umbrella Technology
• Single Umbrella lag screw secures flashing and flash track to roof
• Umbrella technology provides weatherproofing with a long-lasting
mechanical seal
• Flash track is designed for maximum versatility with 6 inches of
North-South adjustability for A Mounts and B Mounts
A Mounts
• Provide a sleek attachment point for the front of the first
row in an array
• Drop-in design means no securing of modules is necessary
as they simply slide into place
B Mounts
• Simple design provides mounting platform between rows of modules
• Clamps onto top of module securing it in place while providing row-
to-row bonding
• Next row of modules easily drops into place as with the A mounts
C Links
• Easily connect rows of modules by sliding between each
module pair
• C Link clamp rotates 90 degrees to provide sleeve i
attachment for bottom of module
• Clamps onto both modules on the top of a row to provide
mechanical and electrical connection
' Wire Management
• New Smartclip design fi rmly retains wires within the
• module frame preventing them from being pulled out
• Wire Saver provides a simple after install solution for
securing hanging cables
Qua� lay, Innovative , Superior
Snap N rack'Solar kou,nting Solutions ar&engineered to optimize materrall use and labor resources
• improve overa.11 installatio,nq6al,ity and
817-132-2860
t
UTILITY METER-
OF
PLAN KEY SERVICE DISCONNECT- G..
PV-i SITE PLAN MAIN SERVICE PANEL- EM
VENT PIPE-
A-I PARTIAL LAYOUT RIDGE IS'-I e" INVERTER-
7-
PANEL PHOTOVOLTAIC-
A-2 ROOF ACCESS PLAN PHOTOVOLTAIC �p FUSED-SERVICE RATED DISCO-
E_I 0 74b
ELECTRICAL ONE UNE MODULE AC DISCONNECT- A��FfSSIONA����\
DIAGRAM �, �� .� � SUPPLY SIDE CONNECTION— 5T
L-I LABELING SCHEMATIC DC vc
EXTERIORCOMBINER
BOX-a FISHER ENGINEERING SERVICES,PG
—I PHOTOS WILLIAM G FISHER,P E.
ROOF 6 — IST FLOOR LOCATION— �5i> P O BOX 30 OAKDALE N Y 11169
RAIL E BASEMENT LOCATION-�> UCENSE NO 814659/631-186 4419
RAFTER
r
z"x 8" /16"o-c s GARAGE LOCATION- w> � S��ci�n
MULTIPLE ROOF$STRUCTURE , �, m
+i Sclnres:shc6ia Sa
I l'-2" SOFFIT
ROOF"1'2'$3" ACTUAL SPAN
ROOF I—
SUNATION
SOLAR
SYSTEMS
III
RAFTER/SPACING 2"X 8"/I6"O C
EXTERIOR WALL RONKONKOMA NY 11119
ACTUAL SPA"IT-2" _ -f ® i ,
ROOF SECTION(TVP)-ROOF"1,2,$3'
SHEATHING PLYWOOD SCALE N T S N5TAl I E
INSTALLER
COLLAR TIES N/A
NUMBER
TYPE/LAYERS ARCH ASPHALT II _ - CUSTOMER INFO
ROOF"6" MARINAKIS RESIDENCE
RAFTER/SPACING 2"X 6"I Ib"OC e
ACTUAL SPAN II'-1" RIDGE 12-9 5" RAF= - ROOF 5 _ 5 5TAR RD
EAST2MARION II I s 9
SHEATHING PLYWOOD SSPAIN
`'
JOB NUMBER
COLLAR TIES N/A - "� •^ 152 y _ E.,
V
TYPE/LAYERS ARCH ASPHALT I I - DATE Q -
5.14
ROOF 3 ,
JOB NOTES
JOB HARDWARE / QTY. RAFTERRAIL ' N/A
OPTIMIZER KITS 55 END CLAMPS 52 2"X 6"
122"RAIL N/A L-FEET 96
ROOF 4
168" RAIL 35 LUGS 13 _
90FFlT
RAIL SPLICES-22 8"X100'SCREEN-4
- �; �:` FULL HOUSE ROOF PLAN
MIEXTERIOR WALL 'gyp SCALE' N.T.S.
D CLAMPS 84 U-ANCHORS N/A f� -
ROOF SECTION(TYP)-ROOF"6"
SCALE N T S.
FASTENER REQUIREMENTS BUILDING REVIEW NOTE NOTES l
TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE 1. AN 18"WIDE CLEARING(FREE OF SOLAR
::- TOTAL ARRAY AREA=1,012 5F ENCLOSED DOCUMENT FOR MINIMUM ACCEPTABLE
WIND LOAD ASCE 10(SEE CALCULATIONS, THIS SHEET)415 EQUIPMENT)SHALL BE PROVIDED ALONG AT
PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS LEAST ONE SIDE OF THE ROOF RIDGE ON THE
PSF MAX SPECIFIED IN THE BUILDING AND/OR RESIDENTIAL SAME SIDE AS THE SOLAR EQUIPMENT OR ON
TOTAL UPLIFT=41.5 PSF X 1,012 SF =41,998 LBS CODE OF THE STATE OF NEW YORK. THIS REVIEW ANOTHER SIDE OF THE RIDGE THAT DOES NOT ADDITIONAL MATERIALS
MODEL PANASONIC vBHN330SA16
330WATT EA FASTENER' DOES NOT GUARANTEE COMPLIANCE WITH THAT CODE HAVE SOLAR EQUIPMENT ON IT IN ADDITION,AN ' "/A
62 6"L X 41.5"W X 1.38"D, 18.05 FT THAT RESPONSIBILITY IS GUARANTEED UNDER THE IS" WIDE PATHWAY(FREE OF SOLAR EQUIPMENT)
)01/201 1 LAG SCREW SPEC 203 2,8104 (FLAT WASHERS REQUIRED TO BE USED WITH LAG SEAL AND SIGNATURE OF THE NEW YORK STATE SHALL BE PROVIDED FROM AT LEAST ONE EAVE
40 81#/MODULE(2.3#/5FLICENSED DESIGN PROFESSIONAL OF RECORD THAT OR GUTTER CONNECTING TO THAT 18" ROOF
MODULE (55))eih 0SAI6 BOLTS)
SEAL AND SIGNATURE HAS BEEN INTERPRETED AS AN RIDGE CLEARING
OPTIMIZER (55)P-400 LAG BOLT WITHDRAWAL VALUE;5/16" DIA,266 LB/IN X 2-INCH THREAD DEPTH= ATTESTATION THAT,TO THE BEST OF THE LICENSEE'S
INVERTER ttl (I)SEII400A-Us 532LB CAP. EACH 2 ROOF SHALL HAVE NO MORE THAN A SINGLE
STRINGING INV al >ZI(I x 15) )S (1 x O S U x 1e) BELIEF AND INFORMATION THE WORK IN DOCUMENT IS LAYER OF ROOF COVERING IN ADDITION TO THE
MINIMUM NUMBER OF LAG BOLTS REQUIRED=41,998 LBS/532 LBS/LAG BOLT=19 ACCURATE SOLAR EQUIPMENT
INVERTER#2 (1)SE50eew-US TOTAL RAIL FEET=490'-0" RAIL FT/19 BOLTS=6'-2" • CONFORMS WITH GOVERNING CODES APPLICABLE DRAWN BY
STRINGING INV a2 K-(1 11S, MAXIMUM SPAN BETWEEN MOUNTING FEET BOLTS"X" USE 5'-4" MAX AT THE TIME OF THE SUBMISSION 3 INSTALLATION-OF SOLAR EQUIPMENT SHALL BE CHRISTIAN BLANK
RACKING sNAP'N'RAGK-SERIES 100 UL 2703 . CONFORMS WITH REASONABLE STANDARDS OF FLUSH-MOUNTED,PARALLEL TO'AND NO MORE
PACKAGE STANDARD THAN fo-INCHES ABOVE THE SURFACE OF THE REVISION
SYSTEM RATING(OC) Is Ise KW PRACTICE AND WITH VIEW TO THE SAFEGUARDING ROOF
EST PRODUCTION CAG 11 4 WEIGHT OF THE INSTALLED SYSTEM SHALL NOT
,536 KWH/YR OF LIFE, HEALTH, PROPERTY AND PUBLIC DATE DESIGNER NOTE
EST-PRODUCTION SOURCE SUNATION PRODUCTION CALCULATOR WELFARE IS THE RESPONSIBILITY OF THE LICENSEE EXCEED MORE THAN 5-PSF FOR 5141a DAVE MEJI4 FINAL
SPECIAL ATTACHMENTS N/A - PHOTOVOLTAICS AND NO MORE THAN 6-PSF FOR xxxXxx N/A ,NIA
STRUCTURAL STATEMENT RESIDENTIAL SOLAR HOT WATER SYSTEMS xxxxxx N/A NIA
5 ANY PLUMBING VENTS ARE NOT TO BE CUT OR
CLIMATIC � GEOGRAPHIC DESIGN CRITERIA - TABLE 8301.20) THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT COVERED FOR SOLAR EQUIPMENT INSTALLATION xxxxxX N/A NIA
THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC ANY RELOCATION OR MODIFICATION OF THE VENT
WIND DESIGN SUBJECT TO DAMAGE MODULE SYSTEM INCLUDING UPLIFT$SHEAR THE REQUIRES A PLUMBING PERMIT AND INSPECTION SCALE
EXISTING RAFTER SIZES$ DIMENSIONS CONFORM TO t N.T.S.
SPECIAL WIND WIND SEISMIC CLIMATE FROST WINTER ICE AIR MEAN IRC-2015 TABLE 8802 5(1)-RAFTER SPANS
GROUND SPEED TOPOGRAPHIC WIND EXPOSURE BORNE DESIGN ZONE WEATHERING LINE TERMITE DESIGN BARRIER FLOOD FREEZING ANNUAL TITLE SITE PLAN
SNOW LOAD (MPH) EFFECTS REGION CATEGORY DEBRIS CATEGORY DEPTH TEMP UNDERLA7MENT HAZARD INDEX TEMP THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE
ZONE REQUIRED MOUNTING BRACKETS AND HARDWARE MEET OR MINIMUM DESIGN STANDARDS FOR BUILDING AND
-MOD SEE EXCEED NEW YORK STATE CODE REQUIREMENTS FOR OTHER STRUCTURES OF THE ASCE 1-le, IRC 2015
2e PSF 13e 5 NO 5 2 G 4A SEVERE 3-e" HEAVY 15 DEG NA EXAMINER 599 sl THE DESIGN CRITERIA OF THE TOWN AND NEW,,YORK STATE UCS 2011 V
�
RIDGE
OF
NEIyN
V N' (6)GARAGE 5 9 E Roor-
G.
0
A
156'TRUE,21-TILT;9,25/12 PITCH V (15)MODULES
'
'fi
ti
NO 074659 Gam
s
.x
FISHER ENGINEERING SERVICES,PG rca
-WILIJAM G FISHER,PE
1'0 BOX 30 OAKDALE MY 111613
PITCH CHANGE v Q32 A33 UC SE NO 014659 1631-166-141 1
4y2"
SUNation
ROOF AREAJ GUTTER Se ar a5 4 111..'d by
HOUSE
SUNATION SOLAR SYSTEMS
GUTTER Ili REMINGTON BLVD
RONKONKOMA SLY Illl9
(1)UPPER IN N W A Roor
A6 A5 A4 336'TRUE,IS'TILT,425/12 PITCH NYSERDA
(23)MODULES INSTALLER
RR
NUMBERj „i', ,,
435ro
BETWEEN ROWS MARINAK15 RESIDENCE
CUSTOMER INFO
SPACIN
/Aksk'-\114�K�i' A A
3025 STAR RP
EAST MARION II935
/
A�:Ak A* A&
N4& -,Aig -A� AJOB NUMBERA.—
�\
DATE
>-5NAI-NRACK ISTEM
4*1 PV (TYPICAL RAIL ACROSS
B�.14
A , AA AA A 1,/ .A..ROW OF ARRAY)
• TWO SHOWN FOR
Av CLARITY) J05 NOTES
I NIA
V-
XG
RIDGE
////X
PHOTOVOLTAIC-
MODULE(TTP) 12
W
vt' V4 *1 »t TwL
ADDITIONAL MATERIALS
1Y I NIA
i / GUTTER
(2)UPPER 9 S E ROOF
-16 Oc IEW TRUE,M*TILT,4 25/12 PITCH
(11)MODULES
DRAWN BY
CHRISTIAN BLANK
<41 REVISION
VENT PI 21 4*RIDGE
DATE DESIGNER NOTE
3• ck
AIS 51418 [DAVE MEJIA FINAL
PARTIAL HOUSE ROOF PLAN XXXXXX N/A NIA
SCALE 3/16"=1'*" XXX<XX NIA NIA
I XXXXXXI N/A I NIA
GUTTER 1-6Y2'
SCALE
TITLE PARTIAL LAYOUT
A16
4y;(3)LOWER 1119 UJ ROOF
246'TRUE,19°TILT..425/12 PITCH
APPROVED BY
W MODULES
Aml
OF NFA
r
DETACHED
GARAGE J'
oho° 074659
. F£SS 1ONa�-
�: FISHER ENGINEERING SERVICES,P r-
4,M - WILLIAM G FISHER,P I-
PO
PO BOX 30 OAKDALE RY 111613
LICENSE NO 014659/6)I-186-4419
SuNbtlon
SaG:r*s't sRm:ld
( Ffill
SUNATION SOLAR SYSTEMS
INV FS -- Ill REMINGTON BLVD
SUB RONKONKOMA NY 11119
ROOF_6
FNYSERDA
STALLER
(EXT) ACCESS ROOF A ROOF SURFACE WHICH PROVIDES ACCESS TO-THE RIDGE OR PEAK OF AN ADJOINING ROOF SURFACE CONTAINING SOLAR PANELS,MODULES OR ARRAYS AND IS UMBER
IN_v ^5
S UI RELATIVELY FREE OF VENTS,SKYLIGHTS AND OTHER OBSTRUCTIONS AND CUSTOMER INFO
2 DOES NOT CONTAIN SOLAR PANELS,MODULES OR ARRAYS,OR 15 A SINGLE RIDGE ROOF WHERE THE TOTAL EDGE WIDTH OF THE SOLAR PANELS,MODULES OR ARRAYS DOES
ACCESS t_: ;:' CB) - NOT EXCEED 33 PERCENT OF THE RIDGE LENGTH MARINAKIS RESIDENCE
R324.1 ACCESS AND PATHWAYS-ROOF ACCESS,PATHWAYS AND SPACING REQUIREMENTS FOR SOLAR PHOTOVOLTAIC SYSTEMS SHALL BE PROVIDED IN ACCORDANCE WITH
SECTIONS R324 11 THROUGH R324 T 6
EXGEPTIONCSk
r,. 3025 STAR RD
,$ '� ,.�, -
:. �y .�'?'", I ROOF ACCESS,PATHWAYS AND SPACING REQUIREMENTS NEED NOT BE PROVIDED WHERE AN ALTERNATIVE VENTILATION METHOD HAS BEEN PROVIDED,OR WHERE EAST MARION 11939
'RooF - VERTICAL VENTILATION TECHNIQUES WILL NOT BE EMPLOYED JOB NUMBER
ACCESS -
'.�36'-'- 2 DETACHED NON-HABITABLE GROUP U STRUCTURES
ROOF I FRONT OF 14CUSE-FACING STREET.DRIVEWAY R3241 4 SINGLE RIDGE ROOFS-PANELS,MODULES OR ARRAYS INSTALLED ON ROOFS WITH A SINGLE RIDGE SHALL BE LOCATED IN A MANNER THAT PROVIDES TWO 36 ,82�/�
INCH WIDE(914MM)ACCESS PATHWAYS EXTENDING FROM THE ROOF ACCESS POINT TO THE RIDGE ACCESS PATHWAYS ON OPPOSING ROOF SLOPES SHALL NOT BE
ta
LOCATED ALONG THE SAME PLANE AS THE TRUSS,RAFTER OR OTHER SUCH FRAMING SYSTEM THAT SUPPORTS THE PATHWAY DATE
EONCSkI ROOFSOOFS WITH SLOPES OF 1 UNITS VERTICAL AND 12 UNITS HORIZONTAL(166 PERCENT)AND LESS2 STRUCTURES WHERE AN ACCESS ROOF FRONTS A STREET,DRIVEWAY OR OTHER AREA READILY ACCES15LE TO EMERGENCY RESPONDERS
- 3 ONE ACCESS PATHWAY SHALL BE REQUIRED WHEN A ROOF SLOPE CONTAINING PANELS,MODULES OR ARRAYS IS LOCATED NOT MORE THAN 24 INCHES WOMM) NOTES
- VERTICALLY FROM AN ADJOINING ROOF WHICH CONTAINS AN ACCESS ROOF
I N/A
-,BI-NOLLV IIIN3n R3241 6 ROOFS WITH VALLEYS-PANELS AND MODULES SHALL NOT BE LOCATED LESS THAN 18 INCHES(45l MM)FROM A VALLEY
EXCEP710N(Sk
vENTILATION-IS'- I ROOFS WITH SLOPES OF 2 UNITS VERTICAL AND 12 UNITS HORIZONTAL(I6 6 PERCENT)AND LESS
"c— R324 T I ALLOWANCE FOR SMOKE VENTILATION OPERATIONS-PANELS AND MODULES SHALL NOT BE LOCATED LESS THAN IS INCHES(451 MM)FROM A RIDGE OR PEAK
Y EXCEPTICN(S)
�RooF' I WHERE AN ALTERNATIVE VENTILATION METHOD HAS BEEN PROVIDED OR WHERE VERTICAL VENTILATION METHODS WILL NOT BE EMPLOYED BETWEEN THE UPPER
ACCESS
MOST PORTION OF THE SOLAR PHOTOVOLTAIC SYSTEM AND THE ROOF RIDGE OR PEAK
_ 2 DETACHED GARAGES OR ACCESSORY STRUCTURES
ROOF 2 ROOF 5
ILI
Q •t„= v f.
C ``i..i
W "}- ^q, ,ACCESS
`'�ti ROOF ..
DRAWN BY
- _ DAVID MEJIA -
ROOF 3 R`
REVISION
DATE DESIGNER NOTE
XXXXXX N/A N/A
XX.XXXX N/A N/A
XXXXXX NIA N/A
r ; XXXXXX N/A N/A
ROOF 4
SCALE
SVA
A 5
N.T.S.
E5
TITLE ROOF ACCESS PLAN
A=2
i
OF cAt
UllUTY
SERVICE
r
M
1 2 14 15 - PLAOUE ��O NO 074659 ����
PLAQUE SERVICE DISCONNECT
• _ = SERVICE DISCONNECT 3 SUPPLY SIDE I OF 2
_ 2 OF 2 COIAIECTION SECOND DISCONNECT
SOLAR EDGE 5EI149eA-U5 INVERTER (ACTIVATES RAPID LOCATED NEXT TO
OPTIMIZER UNGROUNDED WITH 9NUTDOWtU METER PAN
(TTP) RIMARY DISCONNECT
noDULE YBOX INTEGRAL DC SAFETY SWITCH LOCATED IN MAN FISHER ENGINEERING SERVICES,P C
(TYP) 126/249 VA C I-PH SERVICE PANEL 200A WILLIAM G FISHER,PE•
_ MAX 4l 5 AMP
STRING I • • • • • • • O MAIN P O BOX 30 OAKDALE PLY 11169
60A FLL310LE UCEN5E NO 014659/631-186-4419
PV MODULE I 3-POLE
(TTP I SERVICE RATED
DISCONNECT C r#
STRING OF MN ISK AIC OCPD
(15)PANASONIC VBF4N3365AI6 W/ -
SUNation
•^ s.t sl+.rc'
GS)OP-400 CURRENT LIMITING OPTIMIZERS
I 2 IN•SERIES CIRCUIT• 14 15 EXISTING SUNATION SOLAR SYSTEMS
— FEEDER TO
--- 2 5u0 PANEL - Ill REMINGTON BLVD
DG AG RONKONKOMA NY 11'1113
INPUT OUTPUT
4
MAIN SERVICE NYSERDA
STALLE
PANEL INSTALLER
STRING z - • • • • • • • I - - NUMBER
CUSTOMER INFO
STRING OF I — MARINAKIS RESIDENCE
(15)PANASONC VB14N330SAI6 W/ BUILDING
(15)OP-400 CURRENT LIMITING OPTIMIZERS
I 2 IN SERIES CIRCUIT g 10 GROUNDING 3025 STAR RD
ELECTRODE EAST MARION 11939
` JOB NUMBER
_ STRING 3 • • • • - DATE
5.14.18
.14.18
STRING OF _ NOTES
(19)PANASONIC VBHN339SAI&W/ - I N/A
(IO)OP-40&CURRENT LJMITING OPTIMIZERS Z FEEDER TAP- -
IN SERIES CIRCUIT \
SE5000H-US INVERTER CONVERTIBLE
UNGROUNDED WITH - MAIN WG ONLY 59A
INTEGRAL DC SAFETY SWITCH MUST ADD '
120/240 VAC I-PH lvel SBAMP MAIN MAIN
1 2 14 15 MAX 21 AMP BREAKER
— c • • • • • • • _ = O bOA FUSIBLE .
3-POLE
SERVICE RATED
DISCONNECT
-- - SOLAR EDGE --- --- / / / MN 22K AIG30A
OPTMZER /�/ /
Al
GPO $
(TYP) MODULE J-BOXlei
TTP)
STRING i
_ PV MODULE SUB PANEL
trm) 5 DC AC 6
STRING of INPUT-�OUTPUT
(15)PANASONIC VBHN3365A16 WI J
(15)OP-400 CURRENT LIMITING OPTIMIZERS
IN SERIES CIRCUIT
CONDUIT AND CONDUCTOR SCHEDULE _ BUILDING
TAG DESCRIPTION OR CONDUCTOR NUMBER OF CONDUIT CONDUIT RUN GROUNDING
ELECTRODE
CONDUCTOR TYPE GAUGE CONDUCTORS TYPE SIZE LENGTH
I V WIRE - 10 4 LFMC 12S, 30, -
GG 6 I LFMC 125" 30• '
V WIRE 10 4 ,� PVC,BCH 80 12r," I8' _
GC 6 I PVC BCH 80 1.25" 18, _
_ HWN-2 6 3 PvC BCH Be 125' 4•
GC/GEC 6 I PVC BCH 80 t15" 4•
3 HWN-2 6 3 PVG BCH 80 125" e
GG/GEC 6 I _ PVG BCH 80 125' 8" -
4 EC 6 I PVG BCH 80 050" 6 -DRAWN BY
5 v WIRE 10 4 LFMC/EMT 125" 20` DAVID MEJIA
GG 6 1 LFMC/EMT 125" 20 SCALE
6 HWN-2 6 3 PVC BCH 80 125, 4
GC/GEC 6 I PVC BCH 80 1 25" 4• - �•�•�•
7 HWN-2 6 3 ` PVC BCH 80 125" b TITLE ONE-LINE DIAGRAM '
2GC/GC IC -I EC 6 I ' PVSC80 125" 6
8 EC 6 I L1 PVC BCH Be 0 50" 6• _