HomeMy WebLinkAbout41702-Z oG� Town of Southold 7/24/2018
0
A P.O.Box 1179
W 53095 Main Rd
Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 39792 Date: 7/24/2018
THIS CERTIFIES that the building WIRELESS COMMUNICATION SYSTEMS
Location of Property: 23300 Route 25, Orient
SCTM#: 473889 Sec/Block/Lot: 18.-5-13.8
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
6/5/2017 pursuant to which Building Permit No. 41702 dated 6/5/2017
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
wireless upgrade for Verizon to an existing telecommunications facility as applied for.
The certificate is issued to Orient Fire District
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO.
PLUMBERS CERTIFICATION DATED
Aut e Signature
o�SUr F014'04
TOWN OF SOUTHOLD
&0 ,
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
oo�
• t SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 41702 Date: 6/5/2017
Permission is hereby granted to:
Orient Fire District
23300 Route 25
Orient, NY 11957
To: Verizon wireless upgrade as applied for per Southold Town Planning approval.
Replaces BP# 39878.
At premises located at:
23300 Route 25, Orient
SCTM # 473889
Sec/Block/Lot# 18.-5-13.8
Pursuant to application dated 6/5/2017 and approved by the Building Inspector.
To expire on 12/5/2018.
Fees:
PERMIT RENEWAL $250.00
Total: $250.00
:jngp ctor
Form No,6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
I. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations,a certificate
of Code Compliance from architect or engineer responsible.for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and
1. Accurate survey of property showing all property lines, streets, building and unusual natural oristingtopograph oases;
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied,the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy -New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00,
Swimming pool $50.00, Accessory building$50.00, Additions to accessory building$50.00, Businesses$50.00.
2. Certificate of Occupancy on Pre-existing Building- $100.00
3. Copy of Certificate of Occupancy- $.25
4. Updated Certificate of Occupancy - $50.00
5. Temporary Certificate of Occupancy -Residential $15.00, Commercial $15.00
Alteration of existing public
utility wireless communication facility g Date.
6/11/75
New Construction: Old or Pre-existing Building; check one
Location of Property: 23300 Alain Read ( )
House No. Street Orient, New York
Hamlet
Owner or Owners of Property; ent i e nistrict
Suffolk County Tax Map No 1000, Section 18
Block s Lot
Subdivision
i 3 is
Filed Map. Lot:
Permit No. Date Of Permit. New York SMSA Limite
Health Dept. Approval; d Partnership
Applicant:_d/b/a Ver�iz U�__,__8
Underwriters Approval: _
Planning Board Approval.
Request for: Temporary Certificate
Final Certificate. x (check one)
Fee Submitted- $ 50.00 New York Limited Partnership
d/b/a Ve _on [sire ss
B
Applicant ignature
Name: John Walden Title: senior Engineer
Equipment
izv�
__ 1
1 4
m
' 1 .
r �
1 _
I
rml utmwv.•^
70705
�•� ®��� •��• auvxnr ® ?u arr•„r•a
SOUTyo
cOUM'I,N
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLEIG.
[ ] FOUNDATION 2ND [ ] NSULATION
[ ] FRAMING / STRAPPING [ FINAL W/Keb'g7Vk)e&
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
REMARKS:
- kl,,V fn"4W��
lOr1
Avco toofm
DATE 244W5 INSPECTOR a
t
A-P T•
ENGINEERING
February 12, 2018
Town of Southold
Building Department
Town Clerk's Office
54375 NY-25
Southold, NY 11971
Attn: Michael J. Verrity, Chief Building Inspector
RE: Verizon Wireless Cell Site"ORIENT"
23300 Main Road
Orient, NY 11957
SECTION: 18; BLOCK: 5; LOTs: 13.8
Permit #: 41702
Dear Inspector Verrity,
I am a New York State licensed Professional Engineer, retained by Verizon Wireless (VZ) in connection
with the captioned matter above. I have reviewed the completed VZ antenna and associated.
equipment installation at the existing wireless telecommunications facility. It is my opinion that the
completed installation substantially complies with the project plans and specifications, dated January
26, 2017 as permitted.
We trust the foregoing provides the information you have requested. Please do not hesitate to contact
us should you have any questions or comments.
Sincerely, �U
\„`��01- lv�,
APT Engineering °eco �t �l• c �0 °=
`�j ��Nm�
IS
0�
Cr-
M yr rsti W
UU
.00004
Scott M. Chasse, P.E. % �Sslv4
Principal
APT ENGINEERING
3 SADDLEBROOK DRIVE•KILLINGWORTH,CT 06419•PHONE 860-663-1697 FAX 860-663-0935
0 116 GRANDVIEW ROAD•CONWAY,NH 03818•PHONE 603-496-5853 •FAX 603-447-2124
'STATB nNEPGy cbDp,
,
I MIA ,
!�N I tit.r'L Y / I �iV/J e I "Mm
v
A� a
►, 161 ,
1
�1�
TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following,before applying?
TOWN HAi,L Board of Health
SOUTHOLD,NY 11971 4 sets of Building Plans
TEL: (631) 765-1802 Planning Board approval
FAX: (631) 765-9502Survey
SoutholdTown.NorthFork.net PERMIT NO. ����� Check
Septic Form
N.Y.S.D.E.C.
Trustees
C.O.Application
Flood Permit
Examined 320 Single&Separate
Storm-Water Assessment Form
C? / ntact:
l Amato Law Group, PLLC
Approved 220 ail to: Attn: Benjamin Weisel
666 Old Country Road, Suite 901
Disapproved a1c ( Garden City, NY 11530
Phone: (53 797-6363
Expiration ,20
f E C v E Buil ' g Ins ecto
JAN 5 2015
PLICATION FOR BUILDING PE
-
Date December 31 , 2014
KDc DEPT INSTRUCTIONS
TOV'q,i OF SOUTHOLD
-a-."This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans,accurate plot plan to scale.Fee according to schedule.
b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an
addition six months. Thereafter,a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or
Regulations,for the construction of buildings, additions,or alterations or for removal or demolition as herein described.The
applicant agrees to comply with all applicable laws,ordinances,building code,housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections.
t New Y kd artnership d/b/a Verizon Wireless
By:
�Sinature of applicant or name,if a corporation)
Name obn .ea den Title: Senior Engier.-
c/o Amato Law Group, PLLC/Attn: Benjamin Fseiment
666 Old Country Road, Ste. 901, Garden City NY 11530
(Mailing address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder
Lessee
Name of owner of premises Orient Fire District
(As on the tax roll or latest deed)
If applicant is a corporation, signature-of duly authorized officer
Jobn Walden (Senior Engineer-Equipment)
(Name and title of corporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No.
1. Location of land on which proposed work will be done:
23300 Main Road Orient, NY 11957
House Number Street Hamlet
County Tax Map No. 1000 Section 18 Block 5 Lot $
MAILING ADDRESS:
PLANNING BOARD MEMBERS *0 S® �® Southold,.O.Box 1179 1 971
DONALD J.WILCENSHI �® �®
Chair
OFFICE LOCATION:
WILLIAM J.CREMERS Town Hall Annex
PIERCE RAFFERTY a� 54375 State Route 25
JAMES H.RICH III ®�� ` (cor.Main Rd. &Youngs Ave.)
MARTIN H.SIDOR COU ,� Southold, NY
Telephone: 631 765-1938
www.southoldtownny.gov
PLANNING BOARD OFFICE
TOWN OF SOUTHOLD
JUN 5 2015
MEMORANDUM
BLDG DEPT
T0!'V OF';01 1110!9
To: Michael J. Verity, Chief Building Inspector
From: Heather M. Lanza, AICP, Planning Director.
Date: June 5, 2015
Re: Planning Department Report
Verizon Modifications and Up-grades
SCTM#1000-18-5-13.8
23300 Main Road, Orient
As an addendum to the attached Site Plan Use Determination, the Planning Department
has conducted a review of the proposed modifications pursuant to §280-74 B.(2), and
has received a report from our Wireless Technical Consultant, Cityscape, Inc. (see
attached report). We have the following recommendations for this application:
The proposed Verizon modifications and up-grades are in compliance with the General
Requirements of§280-70, therefore, we recommend a Building Permit be issued for this
application with the conditions listed below, and in accordance with the Structural
Analysis Report, dated January 9, 2013, the Structural Evaluation, dated April 20, 2015
and the RF Compliance Assessment and Report, dated March 30, 2015:
Conditions: '
1. The Building Permit must state the following:
a. All feed lines shall be installed inside the monopole structure as approved;
b. Prior to the issuance of a Certificate of Occupancy, the Planning
Department is required to verify that the condition detailed above has
been met.
Thank you for your cooperation.
OFFICE LOCATION: MAILING ADDRESS:
Town Hall Annex JS10 P.O.Box 1179 i
54375 State Route 25 ;,�C` Southold,NY 11971
(cor.Main Rd.&Youngs Ave.)
Southold,NYTelephone: 631765-1938
'. www.southoldtownny.gov
t
o D
JUL 2 3 201 PLANNING BOARD OFFICE
TOWN OF SOUTHOLD
gDII,DING Dom-
TOWN OF SOMOLD MEMORANDUM
To: Michael J. Verity, Chief Building Inspector
From: Heather M. Lanza, AICP, Planning Director
Date: July 23, 2018
Re; Planning Department Report
Verizon Wireless Modifications and Up-grades @ Orient FD
SCTM#1000-18-5-13.8
23000 NYS Route 25, Orient
The Planning Department conducted a final site inspection of the LTE modifications
referenced above on July 17, 2018.
Based on that site inspection, we have received a report from our consultant stating that
all changes and modifications have been constructed in accordance with the provided
construction drawings.
We have found that the LTE modifications and up-grades are in compliance with the
General Requirements of§280-70, therefore, we recommend a Certificate of
Occupancy be issued for this application.
Thank you for your cooperation.
OWNER'S CONSENT AFFIDAVIT
State of New York )
ss..
County of 5 k)
, on behalf of the Orient Fire District, being duly
sworn, deposes and says;
Orient Fire District, is the owner in fee of the premises located at 23300 Main Road,
Orient,New York(the "Property"), and as described in the attached building permit application.
Orient Fire District has authorized New York SMSA Limited Partnership d/b/a Verizon
Wireless to submit the referenced building permit application and consents to the maintenance
and upgrade of the existing communication facility, described in said application, at the Property.
Orient Fire District
B �ksA
Name: --�1
Title:
SwornbeforeRe on this
`lay of 2014
v
Not Public
iNota�Public State of Aew York
No.O1CU6100507
Quaifi?d in commission Expiresi®t20�_�_
AMATO LAW GROUP, PLLC
COUNSELORS AT LAW
666 OLD COUNTRY ROAD
9TH FLOOR
405 LEXINGTON AVE GARDEN CITY,NEW YORK 11530 402 MAIN ST.
CHRYSLER BLDG,26TH FLR ------------- SUITE 204
NEW YORK,N.Y.10174 TEL:(516)227-6363 METUCHEN,NJ 08840
TEL:(212)485-6000 FAX:(516)227-6367 TEL:(732)317-1511
FAX:(212)485-6001 FAX:(732)317-1513
December 31,2014
VL4 EXPRESS MAIL
Town Hall Annex Building
54375 Route 25
P.O. Box 1179
Southold,NY 11971
Re: Building Permit Application (the "Application") by New York SMSA Limited
Partnership`d/b/a Verizon Wireless ("Verizon Wireless") to the Town of Southold (the
"Town") in connection with the maintenance and upgrade of the existing public utility
communication facility located at 23300 Main Road, Orient, New York, with Suffolk
County Tax Map designation Section 18/Block 5 /Lot 13.8 (the"Property")
Verizon Wireless Ref.: Orient AWS/Our File No. 100-408
Dear Sir/Madam:
In connection with the above-referenced Application submitted to the Town, enclosed herewith
please find the following:
1. One(1)original Application for Building Permit, completed and executed;
2. One(1)original Owner's Consent Affidavit, executed by the Property owner;
3. Four(4) surveys of the Property;
4. Four(4) sets of construction drawings;
5. Certificates of Worker's Compensation,Liability, and Disability Insurance; and
6. Check payable to the "Town of Southold" in the amount of $550.00, representing the
Application filing fee.
Upon completing your review of the foregoing materials, kindly issue a building permit to
Verizon Wireless at your earliest convenience.
Please do not hesitate to contact me, should you have any questions or concerns. Thank you.
Sincerely,
u
Encls. Benjamin Weisel
• AMATO LAW GROUP, PLLC
COUNSELORS AT LAW
666 OLD COUNTRY ROAD
9TH FLOOR
405 LEXINGTON AVE GARDEN CITY,NEW YORK 11530 402 MAIN ST.
CHRYSLER BLDG,26TH FLR ------------- SUITE 204
NEW YORK,N.Y.30174 TEL:(516)227-6363 METUCHEN,NJ 08840
TEL:(212)485-6000 FAX:(516)227-6367 TEL:(732)317-1511
FAX:(212)485-6001 FAX:(732)317-1513
June 16, 2015
VIA EXPRESS MAIL
Town of Southold UN 1 7 2015
Building Department
P.O. Box 1171
Southold New York 11971 [kPG r EP f
Attn.. Connie Bunch T 1,OF>`?t'
Re: Building Permit Application (the "Application") by New York SMSA Limited
Partnership d/b/a Verizon Wireless to the Town of Southold (the "Town") in connection
with the maintenance and upgrade of the existing public utility communication facility
located at 23300 Main Road, Orient, New York, with Suffolk County Tax Map
designation District 1000, Section 18, Block 5, Lot 13.8
Verizon Wireless Ref.: Orient AWS/Our File No. 100-408
Dear Ms. Bunch:
In connection with the above-referenced Application submitted to the Town on December 31,
2014, and pursuant to your request, enclosed please find the following documents:
(1) One (1) copy of the Memorandum from the Town Planning Department to the Building
Department,recommending issuance of a building permit;
(2) One(1)Application for Certificate of Occupancy; and
(3) A check made payable to the Town of Southold in the amount of$50.00, representing the
fee.
If everything is in order, kindly issue the building permit at your earliest convenience and forward
a copy to my attention.
Should you have any questions, please do not hesitate to contact me. Thank you for your attention
to this matter.
Sincerely,
Lisa A. Covert
Encls.
AMATO LAW GROUP, PLLC
COUNSELORS AT LAW
666 OLD COUNTRY ROAD
9TH FLOOR
405 LEXINGTON AVE GARDEN CITY,NEW YORK 11530 402 MAIN ST.
CHRYSLER BLDG,26TH FLR ----------- SUITE 204
NEW YORK,N.Y.10174 TEL:(516)227-6363 METUCHEN,NJ 08840
TEL:(212)485-6000 FAX:(516)227-6367 TEL:(732)317-1511
FAX:(212)485-6001 FAX:(732)317-1513
January 30, 2017
VIA EXPRESS MAIL ,RN 3 2011
Town of Southold
Building Department
P.O. Box 1179
Southold,New York 11971 �O
Re: Building Permit No. 39878 (the "Building Permit") issued to New York SMSA
Limited Partnership d/b/a Verizon Wireless ("Verizon Wireless") by the Town of
Southold (the "Town") in connection with the upgrade of the existing public
utility communication facility (the "Communication Facility") located at 23300
Main Road, Orient,New York, with Suffolk County Tax Map designation Section
108 /Block 5 /Lot 13.8 (the "Property")
Verizon Wireless Ref.: Orient ANTMO/Our File No. 100-0408
Dear Sir or Madam:
In connection with Verizon Wireless' Building Permit for the upgrade of the existing
Communication Facility located on the Property, enclosed please find four (4) sets of revised
construction drawings (the "Revised CDs") signed, sealed and issued by APT Engineering on
January 26, 2017, which should replace the previously filed construction drawings approved by
the Town on June 17, 2015.
Please note that the Revised CDs have been amended to reflect a few changes, which
have been "bubbled", including: (1) different antenna models, (2) installing three (3) MDBs
instead of two (2) MDBs within the existing equipment shelter, and (3) installing nine (9) RRHs
within the existing equipment shelter.
Upon your review, please issue an amended Building Permit at your earliest convenience.
If you should have any questions regarding the foregoing, please do not hesitate to contact me.
Thank you for your attention to this matter.
Sincerely,
Shannon Bahnsen
Enclosures
Pontino, Susan
From: John Coughlin <jcoughlin@rnhclaw.com>
Sent: Wednesday, February 07, 2018 3:29 PM
To: Pontino, Susan
Subject: RE:Verizon Wireless Upgrade - 23300 Route 25 Orient
Hi Susan—I will certainly reach out to my contacts at Verizon and relay the message.
Were you able to confirm as to what was needed for the AT&T Horton's Lane site (the reference to "verify location on
site plan")?
Thanks!
John J. Coughlin
Re, Nielsen, Huber & Coughlin, LLP
36 North New York Avenue
Huntington, New York 11743
Telephone: (631) 425-4100
Facsimile: (631) 425-4104
E-Mail: jcoughlin@rnhclaw.com
This e-mail message and attached files,if any,are confidential and intended solely for the use of the addressee(s)named above. This
communication may contain information protected by attorney-client,work product, or other privileges.If you are not the intended
recipient or his/her agent,any review,use, dissemination,forwarding,printing,copying,or other distribution of the information in this
e-mail is strictly prohibited.If you have received this confidential communication in error,please notify the sender immediately by
reply e-mail message and permanently delete the original message.
From: Pontino, Susan [mailto:susan.pontino@town.southold.ny.us]
Sent: Wednesday, February 07, 2018 3:24 PM
To: John Coughlin
Subject: Verizon Wireless Upgrade - 23300 Route 25 Orient
Hi John,Our building inspector did the final inspection on this permit last Friday. A woman called today asking what else
they needed to close out the permit and I neglected to tell her to contact our Planning Department as they need to go
out and to verify they have met their conditions also. I am not sure who the woman was and I was wondering if you
knew her name and had a contact number for her. I am assuming she was with Verizon Wireless. Thank you in advance
for your help.
Susan Pontino
Clerk/Typist
Southold Town Building Department
i
AMATO LAW GROUP, PLLC
COUNSELORS AT LAW
666 OLD COUNTRY ROAD
9TH FLOOR
405 LEXINGTON AVE GARDEN CITY,NEW YORK 11530 402 MAIN ST.
CHRYSLER BLDG,26TH FLR --` SUITE 204
NEW YORK,N.Y.10174 TEL:(516)227-6363 METUCHEN,NJ 08840
TEL:(212)485-6000 FAX:(516)227-6367 TEL:(732)317-1511
FAX:(212)485-6001 FAX:(732)317-1513
March 22, 2 �
DD
VIA FEDERAL EXPRESS BAR 2 3 2018
Town of Southold
Building Department
Town Hall Annex
54375 Main Road T®WNOF SOUTHOLD
Southold,New York 11971
Re: Request to Close Out Building Permit No. 39878/41702 (the "Building Permit")
issued to New York SMSA Limited Partnership d/b/a Verizon Wireless by the
Town of Southold (the "Town") in connection with the upgrade of the public
utility wireless communication facility located at 23300 Main Road, Orient, New
York, with Suffolk County Tax Map designation Section 108, Block 5, Lot 13.8
NYSMSA Site Reference: Orient ANTMO/Our File No. 100-408
Dear Sir/Madam:
In connection with the close out of the above-referenced Building Permit, enclosed please
find one (1) original engineer's closeout letter, issued by APT Engineering. Copies of the
Building Permit and the cover sheet of the approved amended construction drawings are also
enclosed for your reference.
If everything is in order, please issue the Certificate of Occupancy at your earliest
convenience.
Should you have any questions, please do not hesitate to contact me. Thank you for your
attention to this matter.
Si ere y,
:2
Je sic
Zalin
Enclosures
Bunch, Connie
From: Jessica Zalin <JZalin@amatofirm.com>
Sent: Tuesday, March 27, 2018 1:30 PM
To: Cummings, Brian A.; Bunch, Connie
Cc: Michaelis,Jessica
Subject: 23300 Main Road, Orient, New York; SCTM # 18-5-13.8
All—
In connection with the closeout of Verizon Wireless' building permit at the above-referenced site, please have the
Planning Department verify that the conditions detailed have been met.
Should you have any questions, please do not hesitate to contact me.
Thank you,
Jessica Zalin, Esq.
Amato Law Group, PLLC
666 Old Country Road,Suite 901
Garden City, NY 11530
Tel: (516) 227-6363
Fax: (516) 227-6367
E-Mail: izalin@amatofirm.com
Website:www.amatolawgroup.com
CONFIDENTIALITY NOTICE:This electronic message contains information from the law firm of Amato Law Group,PLLC.This e-mail and any files
attached may contain confidential information that is legally privileged.If you are not the intended recipient,or a person responsible for delivering
it,you are hereby notified that any disclosure,copying,distribution or use of any of the information contained in or attached to this transmission is
STRICTLY PROHIBITED.If you have received this transmission in error,please forward same to sender and destroy the original transmission and its
attachments without reading or saving in any manner.
1
Subdivision N/A Filed Map No. N/A Lot N/A
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy Public utility wireless communication facility/Fire District
b. Intended use and occupancy No change
3. Nature of work(check which applicable):New Building Addition Alteration
Repair Removal Demolition Other Work Proposed upgrade
(Description)
4. Estimated Cost $17,500.00 Fee 5550.00
(To be paid on filing this application)
5. If dwelling,number of dwelling units N/A Number of dwelling units on each floor N/A
If garage, number of cars N/A
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. N/A
7. Dimensions of existing structures,if any: Front N/A Rear N/A Depth N/A
Height 90 feet Number of Stories N/A
Dimensions of same structure with alterations or additions: Front N/A: No change Rear N/A: No change
Depth N/A: No change Height N/A: No change Number of Stories N/A
8. Dimensions of entire new construction: FrontN/A: No change RearN/A: No change Depth N/A: No change
Height N/A: No change Number of Stories N/A
9. Size of lot: Front 450.52±feet Rear 570.7#feet Depth W: 458.35tfeet/E: 456.90=feet
10. Date of Purchase N/A Name of Former Owner N/A
11. Zone or use district in which premises are situated R-80
12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO x
13. Will lot be re-graded?YES NO x Will excess fill be removed from premises?YES NO x
23300 Plain Road
14.Names of Owner of premises orient Fire District Address orient, NY 11957 Phone No. (631) 323-2445
T-sName of Architect APT Engineering Address Fillip Borth CT 66419 Phone No (s6 663-1697
orizon a
Name of Contractor XnWam Engineering Group Address Fort Lee, NJ 07024 Phone No. (2o1) 969-8812
Telcom
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO N
* IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? *YES NO x
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey,to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES NO x
* IF YES,PROVIDE A COPY. *To the best of our knowledge
STATE OF NEW YORK)
SS:
COUNTY OF Nassau )
John Walden , on behalf of New York SMSA Limited Partnership
d/b/a Verizon Wireless being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)Heisthe Senior Engineer-Equipment
(Contractor,Agent,Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the applicati��° �eith.
Sworn to before me this
�
piR1622.9r045'.:day of�nV(.rt�►'►bt..l- 2b ;• 40'AtIF1ED 1N
SUFGOt CEXp�Y Y 33ew York affiit a ship d/b/a Verizon Wireless
Comm.
Kotayy Publicy� •tqv- *-�:° "Name: J.,M// of Applicant
0 F�N���d`° Title: Senior Engineer-Equipment
Southold, New York ° ■����■�
ago a
Telecommunications Site Review
New York Equipment Upgrade Consultants, Inc.
7050 West Palmetto Park Road,#15-652
Boca Raton,FL 33433
Tel:877-438-2851 Fax:877.220-4593
June 1,2015
Heather M. Lanza,AICP D E `�
Planning Director JUN 0 2 2015
Town Hall Annex Building
54375 Route 25 Southold Town
Southold,New York 11971 Planning Board
RE: Verizon Wireless Application
SCTM#1000-18-5-13.8
23300 Main Road,Orient Point
Dear Ms. Lanza,
At your request, on behalf of the Town of Southold, New York, ("Town") Cityscape
Consultants, Inc. ("CityScape") in its capacity as telecommunications consultant for the Town,
has considered the merits of an application provided by Verizon Wireless ("Applicant") to
modify their facilities on an existing ninety (90) foot concealed slick-stick support structure
owned by American Tower Company ("Tower Owner) and located at 23300 Main Road in
Orient Point,New York, see figure 1.
All wireless service providers are in the process of upgrading and modifying equipment
in an attempt to maintain their current subscriber base while simultaneously providing improved
and advanced services. Verizon, T-Mobile and AT&T have been most active with these types of
upgrades in the eastern half of the United States with Verizon and T-Mobile launching more
high-speed wireless broadband services over other carriers. Short-term system modifications are
underway to overcome current over-capacity problems while future facilities will be
concentrating more towards the wireless Internet electronics as more spectrum is being delivered
to meet consumer demands.
The Applicant's proposed modifications are intended to provide Verizon subscribers with
newer technologies known as fourth generation (4G) LTE, better identified as high-speed
wireless broadband. The Applicant has proposed to abandon the concealment canister at the
sixty-five (65) foot level and remove six (6) existing antennas and the twelve (12) feed lines.
The Applicant will replace the six (6) antennas with three (3) new antennas, and six (6) TMA's
(top mounted amplifiers) in the top concealment canister at the eighty-four feet and four inches
(84.4') height of the support structure. The Applicant will replace the twelve (12) existing 7/8"
coax feed lines at sixty-five (65) feet with twelve (12) new 7/8 inch coax feed lines to the new
top mounted antennas. Also collocated on the pole is, AT&T which will remain in the center
canister located at 75 feet as well as the Orient Fire Department with equipment (2 short stub
antennas and 2 whip antennas)for public safety located at approximately fifty-two (52) foot level
and an existing double whip antennas mounted at, ninety (90) feet. There will be no visible
changes to the concealment structure; see final pole configuration as noted in figure 2.
Carrier:Verizon Wireless
SCTM#1000-18-5-13.8 EEO=
Southold,New York
June 1,2015 Consultants, Inc.
Page 2 Telecommunications Site Review
New York Equipment Upgrade
The Applicant provided a minimal Structural Evaluation statement dated April 20, 2015
that did not include any actual tower stress rating analysis but claimed the facility was adequate
for the proposed loads. CityScape reviewed the previous Structural Analysis dated January 9,
2013 which reported a final tower rating of 99% out of an allowable maximum of 105%. Since
the Applicant will be removing equipment and replacing feed lines, Cityscape considers the
stress level will remain reasonably consistent at 99%; see figure 3. It's also important to note that
the overturn moment of a waving flag has more loading concerns than the weight of any internal
antennas and feed lines. The pole was designed to support the additional loading caused by a
flag which is greater than any internally mounted antennas and feed lines.
In addition to the structural statement the Applicant supplied a previous RF Compliance
Assessment and Report dated March 30, 2015, with a calculations table indicating the human
exposure concerns will not be an issue and the Applicant will be in compliance with applicable
FCC rules regarding human exposure to RF energy; see figures 4 and S. The proximity of all the
existing and proposed antennas including the Orient Fire Department antennas will not create a
potential health risk to humans according to the FCC OET Bulletin 65; Supplemental C;
categorical exclusion. The last visit at the site by CityScape found the main gate open and not
secure, see figure 6. CityScape recommends the Applicant and Tower Owner be advised of the
potential lack of security at the facility.
Under the Middle Class Tax Relief and Job Creation Act of 2012 ("The Act") any
personal wireless facility collocation, modification or upgrade may qualify for streamlined
processing and administrative approval if the request does not increase the structure height and
girth by 10% or 20 feet, whichever is greater, and does not require any excavation outside the
existing ground compound. The Act further states that if an application meets the criteria, the
application must be approved and cannot be denied. Cityscape has determined the application,
herein complies with the Act and is qualified for streamlined processing.
The Applicant's proposed installation, if built as designed, will be in compliance of
applicable federal and local codes. It is the opinion of the undersigned the proposed
improvements are justified and will provide the Applicant's subscribers high-speed wireless
broadband service in and around the Town. Should the Town choose to approve the subject
application, CityScape recommends approval with the following conditions:
1. All feed lines shall be installed inside the pole structure; and,
2. All concealment panels shall be sufficiently secured.
Respectfully submitted,
4� -0��, �1�
Richard L. Edwards
FCC Licensed
PCIA Certified
CityScape Consultants,Inc.
Carrier:Verizon Wireless EMENOME
SCTM#1000-18-5-13.8 Lai 40 0 ift
Southold,New York
June 1,2015 Consultants, Inc.
Page 3 Telecommunications Site Review
New York Equipment Upgrade
• DeLorrne Street Atlas USA®2009
4�
Island-,
at
A
yi
V D
A�
V
Al
X
4
o
L
25
T"'IT,
J
jl�f
&
,,-..... b��� ` � It i� �,,, fit'q �; - -
\2
S'
AQ
N cm
T, --
R
1A
vJ'
Data use subject to license, ft
Q DeLorme,DeLorme Street Allas USA®2009 0 180 360 540 720 900
wwwdelarmp—com MN(13 9-VV) Data Zoom 15-0
Figure 1. Site Location
Carrier:Verizon Wireless
■■■■■■■
GSCTM#1000-18-5-13.8 IB
Southold,New York
June 1,2015 Consultants, Inc.
Page 4 Telecommunications Site Review
New York Equipment Upgrade
A!Cblic Safety Antennas
4 REPLACE(0)EXIST.VEPEZON
WIRELESS UNIPOIE MOUNTED
e a a •e t •e a I SECTOR ANTENNAS(W.21(r,
,330 WI(S)NEW ANTENNAS
s'
190':110►,3309 ADD M1 DIPLEXERS.
REPLACE FMT.COAX CAM.ES
RELOCATE TO TOP
CONCEALMENT CYLINDER
t a •e a e e e a a
I a ee . eee 'e e
r
r
blic Safety Antennas
(1�7+9'0 REPIJICEMENT
_COAX CABLES ROUTED
WITHIN POLE TO RELOCATED
ANTENNA CAVITY
Ir,
i` 'MOST,W*HIGH UNFOLE
I
1. - E](IST.VERIZdV WIRELESS
( - 11�8�P3Q'(34bs SFl
,EQUIPMENT SHELTER w!
-- I .DIESEL GENERATOR 6 MOPS
UNITS.ADD NEW RACK
MOUNTED C 61NEfS WITHIN
°k _�"
=i'W�9"'}
tea, ,r:<����.� u�, ,� `r° • ,. „�•��-�• •e'`.��";�.o.��,..r,'�»'
(14's AMSLf
Figure 2. Final Antenna Configuration
t .
Carrier:Verizon Wireless i
SCTM#1000-18-5-13.8 o G
Southold,New York
June 1,2015 Consultants, Inc.
Page 5 Telecommunications Site Review
New York Equipment Upgrade
Eng.Number 57930935
AL April 20203,
Page 2 of 2
AMM 30VVERO
GOd.P O"i AY(a�
Proposed Eatfivinent
Eleyatiaa'(ft)
Moimrt RAD COY Ant am MaurtType Eines Carrier
85A 850 5 RfsivAP5owficaL FES!
3 Anteldb&VXOBMGM {1217{S`Cw�t Verizon
ND=te"esr-e=cdefA-edash tab vebatomofsxd.trill:=tobattcmofinwait'=eevadon'sdefined:soenwafamemra
-above Vzdde tenet IAGEj.
Install proposed wax inside pole.
The existing and{uoposed loads listed in the tables above are compared to the tower's current design capacity
or previous structural analysis. The tower should be re-evaluated as future loads are added or if actual loads are
found different from those listed in the telt( The sub"ect tovsrer and foundation nre Qd uote o supportthe
above stated loads In conformance with specified requirements.
I1mm-aed by.
nw Kuplr'PE
t7'rre"OTWOcrei
Eagimedrg
Apr 20 2015 4.46 PM
Atfcjb
ATCT***tS*svk4 ke--SCORttowPjftet SWisM•ran(.REM1saal9*&=GM%-9 MEE540fu=wxar�mr�nuw�eedn
Figure 3. Structural Statement
Carrier:Verizon WirelessANN
����■���
SCTM#1000-18-5-13.8 IBMMM a O
Southold,New York
June 1,2015 Consultants, Inc.
Page 6 Telecommunications Site Review
New York Equipment Upgrade
PiNNACtE TE1ECt?M GROUP
FmfeWbnaf and Technfba7 SeMbes
ANTENNA S11TEFCC RF COMP 1ANCE
ASSESSMENT ANd REPORT
PREPAREd I'oR
Nav YORk SMSA 1:15liTEd PARTNERShip
d/b/A VERiZ®N-WiREIESS
" OWENT°I SITE
2000 MAiN ROAd
ORIENT, NY
MARch 30, 2015
14 RidgEd,*AvrrNUE i S67E 209 • OE&z Knotts, NJ 07927 • 973451,1630
Figure 4. RF Calculations
Carrier:Verizon Wireless
ift
SCTM#1000-18-5-13.8 CEO=
Southold,New York
June 1,2016 Consultants, Inc.
Page 7 Telecommunications Site Review
New York Equipment Upgrade
TROUTMAN SANDERS LLP
ATTORNEYS AT LAW
A Up/TSO U46101T PARTNSR9NIf
Ms,Jackie-Carver
May 6,2008
Page 2
For this proposed facility;Verizon Wireless intends to co-locate onto an existing 165•foot
monopole owned by Crown Castle,and to lease a lb'x 35'parcel of land on which to locate an
equipmeni'shelter. Access to the leased premises will be provided via an existing access and
utility easement running from T.Godley Way to the proposed site. Section 80=11.3 of the City
of Pooler Code of Ordinances allows for administrative approval of the co-Iocation of additional
antennas on existing.towers.
Verizon Wireless has selected this site to ensure that increasingly relied - wireless
telecommunications service is provided in a safe and uniform manner throughout tbis-portion of
the City of Pooler and the surrounding area. This portion of the City,specifically around Godley
Station Boulevard and the surrounding neighborhoods,currently have inadequate coverage,
resulting in frequently dropped calls or no service at:all. This co-location will allow Verizon
Wireless to provide suitable.coverage to this portion of the City.
Verizon Wireless ensures that the proposed co-location and equipment shelter wiff be
maintained in coanpliance with'the,standaz'ds contairied.in applicable local building codes-and the,
applicable;standards for such telecommunications facilities: Verizon Wireless will obtain all
necessary Federal Comiriinieatipns Commission("FCC'.�'aiid Federal AviationAdiuinistration
("FAA's approvals for construction and operation=at this tacatioii.-As tivith all its facilities, ,- -
Verizon-Wireless=viii coinstiuct and operate this facility in accordancewith all'applirable FCC
and FA:6'regulariiiYis:
I appreciate your thoughtful consideration of this request,I encourage you to contact me
should you have any questions or require any additional information,and.I look forward to
working with you on this important matter.
Very truly yours,
J
Jennifer A.Blackburn
Figure 5. Statement of Compliance with Exposure
1 �
• w � � i
l no, ecure
If
all ,
j
� ' ! � ' � I ' I � � y �1t •t r A
^.r�"`•I'" ' r ..'n°'l'=•}t, ,._- � � .e4w7.,r>t•i+�iw}>x. (( .•.•�•�,�� .�' `" •^
t 1 1
\ a
verizonv
■ 4 CENTEROCK ROAD
WEST NYACK,NY 10994
v rizon APT
ENGINEERING
35 ADDLEBROOKORIVE PHONE(860) 63-1697
KILLINGWORTH,CT06419 FAX(860)-663-935
WvWVALLPOINTSTECH COM
APPROVALS
WEST NYACK NEW YORK LANDLORD DATE
RF ENGINEER GATE
WIRELESS , COMMUNICATIONS FACILITY �]
CONSTRUCTION DOCUMENTS
NO DATE REVISION
0 10131/14 FOR REVIEW SPM
1 11106/14 FOR FILING SPM
2 1126117 FORREVIEW SPM
"ORIENT"
L6L--
6
23300 MAIN ROAD
ORIENT, NY 11957
DRAWING INDEX SITE INFORMATION
VZ SITE NAME "ORIENT"
T-1 TITLE SHEET&INDEX VZ LOCATION CODE 157730
VZ PROJECT CODE 20161327697
PROJECT LOCATION 23300 MAIN ROAD DESIGN PROFESSIONALS OF RECORD
SPA SITE PLAN&NOTES ORIENT,NY 11957
PROF SCOTT M CHASSE P E
COMP APT ENGINEERING
A-1 PLANS,ELEVATION&ANTENNA DETAILS SITE TYPE/DESCRIPTIO REPLACE(6)OF(6)EXISTING ANTENNAS WITHIN EXIST ADD 3 SADDLEBROOK DRIVE
UNIPOLE&RELOCATE TO TOP CONCEALMENT CYLINDER KILLINGWORTH,CT 06416
ADD(1)NEW EQUIPMENT RACK(3)WALL MOUNTED MDBs&
A-2 ANTENNA MOUNTING&EQUIPMENT DETAILS (9)RACK MOUNTED RRHs WITHIN EXIST EQUIPMENT SHELTER OWNER AMERICANTOWER
CORPORATION
PROPERTY OWNER AMERICAN TOWER CORPORATION
A-3 SCHEMATIC&SPECIFICATIONS NOTE
LEASING CONTACT ANTHONY LONGINETTI IT IS A VIOLATION OF NEW YORK STATE
(908)256-3405 EDUCATION LAW ARTICLE 145,SECTION
7209(2)FORANY PERSON,UNLESS
ACTING UNDER THE DIRECTION OF A
CONSTRUCTION CONTACT PETER MCCARTHY LICENSED PROFESSIONAL ENGINEER OR
^r (631)649-2730 LAND SURVEYOR,TO ALTER AN ITEM IN
ANY WAY IF AN ITEM BEARING THE SEAL
OF AN ENGINEER OR LAND SURVEYOR IS
_ ENGINEER CONTACT SEAN MCDONOUGH ALTERED,THE ALTERING ENGINEEROR
(1!1001 (860)663-1697 x205 LAND SURVEYOR SHALL AFFIX TO THE
ITEM HIS SEAL AND THE NOTATION
- - LATITUDE 41*08'33 50'N "ALTERED BY"FOLLOWED BY THE
SIGNATURE AND THE DATE OF SUCH
Urs6uDRad9 f 0[rli(E LONGITUDE 72°17'58 00'W ALTERATION,AND A SPECIFIC
ELEVATION 16'±AMSL DESCRIPTION OF THE ALTERATION
Orval Servlca C6ot0r� DISTRICT 1000
,rf SECTION 18 VERIZON AT
Dys:aTlc�ds !
BLOCK 5 "ORIENT"
` �"E7e�r ca{aleSct�Cc{ I LOTS 138 SITE 23300 MAINROAD
ZONING R-80 ADDRESS ORIENT,NY 11957
'® Mg\P4d APT FILING NUMBER NW41PCS1590
PROJECT CODE 20161327697
LOCATION CODE 157730
SITE q) 70,�,
VZ CM. PKM DRAWN BY CSH
_ yV DATE 10/37114 CHECKED BY SPM
aGlifin{CRvai'y$LU1q ,
} SHEET II\L�\\\\\ /l1//77i
SOF
� f �E . py
I n
JAN 3 1 2017HTDM
VICINITY MAP -
SCALE-1"=500'
]BUILDING
DEPT.
TOWN
-TT /ff4i�'� ♦1 D��r
ZONING TABLE SOUTHOLD
ITEM ALLOWED
80 ALLOWED EXISTING PROPOSED verizonJ
MAX HEIGHT(FT) 35 •90'± NO
MIN LOT AREA(SF) 80,000 189,572± NO
MIN LOT WIDTH(FT) 175' 226- NO 4 CENTEROCK ROAD
MIN LOT DEPTH(FT) 250' 458 35'± NO
WET A
MINIMUM FRONT YARD SETBACK(FI) EO' 83 OB NC
MINIMUM SIDE YARD SETBACK-ONE(FI) 20' 7542 NO
MINIMUM SIDE YARD SETBACK-BOTH(FT) 45' 155'± NO
MINIMUM REAR YARD SETBACK(FT) 75' 217 58'± NO
MAX LOT COVERAGE(%) 20% 55% NO
APT
NA=NOT APPLICABLE NO=NO CHANGE
MAIN ROAD (S.R 25) ENGINEERING
EXISTING DIMENSIONAL NON-CONFORMITY 3SADOLE9ROOK DRIVE PHONE @6a)-66&1697
KILLINGWORTH,CT 06419 FAX(660)-663-0935
SITE PLAN REFERENCE WWWALLPOINTSTECH COM
700 —
�
APPROVALS
1 PLOT PLAN&POLE ELEVATION TITLED ORIENT FIRE DISTRICT,23300 MAIN ROAD,ORIENT,NY 957 PREPARED FOR BEACON WIRELESS MANAGEMENT,P O BOX 303,HAMPTON BAYS,NY � LANDLORD DATE
11946 REV 4,DATED 02/23/06 MOVE COMPOUND BEHIND F H PREPARED BY MICHAEL
WALKER DESIGN/BUILDER LLC,500 HORSENECK ROAD,DARMOUTH,MA 02784I� RF ENGINEER DATE
2 SITE MEASUREMENTS TAKEN BY APT ENGINEERING ON 01/11/12,01/16/12,09/10/14,&09/22/15 OIT- - I
CONSTRUCTION DOCUMENTS
NO DATE REVISION
0 10/31/14 FOR REVIEW SPM
W 1 11/06/14 FORFILING SPM
2 1126/17 FOR REVIEW SPM
¢]I� 3
I 4
PAVED NlcO1D 5
AREA
EXISTING OIC 6
FIRE co
rlQ STATION
�L PAVED 1
1
PAVED AREA L _
' AREA
m I
� --� —N 87-47130°E
1—
EXISTING 224 52'
HIGH
LUNIPOLE
1 I 00 Oo
0 020
i'� i EXISTING
I BUILDING DESIGN PROFESSIONALS OF RECORD
0 PAVED
AREA L ,®� A_1 11 PROF SCOTT M CHASSE P E.P
COM
APTENGINEERING
ADD3 SADDLEBROOK DRIVE
KILLINGWORTH,CT 06419
I OWNER AMERICAN TOWER
1 CORPORATION
1 EXISTING 1
BUILDING NOTE
R IS A VIOLATION OF NEW YORK STATE
I EDUCATION LAW ARTICLE 145,SECTION
N 7209(2)FOR ANY PERSON,UNLESS
ACTING UNDER THE DIRECTION OF A
oLICENSED PROFESSIONAL ENGINEER OR
O LAND SURVEYOR,TO ALTER AN ITEM IN
O_ 0i1p ANYWAY IF AN ITEM BEARING THE SEAL
OIC O OF AN ENGINEER OR LAND SURVEYOR IS
07ALTERED,THE Im LAN SURVEYORI
SHAL AFFXTOTHETERING ENGINEER TEM HIS SEAL AND THER
O ORISUBJECT SITE
O (ALTERED BY'FOLLOWED BY THE
DISTRICT
DIS FIRE DISTRICT
z DISTRICT 1000, SIGNATURE AND THE DATE OF SUCH
SECTION 18, , ALTERATION,AND A SPECIFIC
BLOCK 05, DESCRIPTION OF THE ALTERATION
I LOT 13 8 1
I VERIZON AT
"ORIENT"
SITE 23300 MAIN ROAD
ADDRESS ORIENT,NY 11957
APT FILING NUMBER NY141 PCS7590
S 83'_03,50°E — — — _ _ — PROJECT CODE 20161327697
570 70' — — LOCATION CODE 157730
VZ CM PKM DRAWN BY CSH
DATE. 10131114 CHECKED BY SPM
1 SITE PLAN (nHHHh(numruri
SP-'I SCALE.1"=40'-11" (IN FEET)11nch= w R F= �(((
SHE
M.
SpgE NUM
_ d
/
MAIN ROAD -
ver izon%
REPLACE(6)EXIST VERIZON PANEL ANTENNAS(60°,
PROPERTY LINE(TYP) 190°,282°)MOUNTED WITHIN EXIST 90'2 HIGH 4,5 130,., A CENTEROCK ROAD
q_7 A_2
UNIPOLE REPLACE EXIST COAX CABLES RELOCATE WEST NYACK,NY 10994
Q ANTENNAS TO TOP CONCEALMENT CYLINDER EXIST WAVEGUIDE
ENTRY PORT W/(12)U.'
H
EXIST FIREHOUSE O COAX CABLES$(2)%&
EXIST AT&T PANEL ANTENNAS(TYP) ! r YY CIPS LINES
A 1 EXIST COMPOUND ,_( REPLACE(12)%'COAX 0 48°
REPLACE(12)EXIST VERIZON%COAX DOOR DOOR APT
r CABLES ROUTED FROM VERIZON EQUIPMENT ENGINEERING
O EXIST PARKING LOT(iYP) SHELTER TO VERIZON PANEL ANTENNAS i LES ,
DO U
/¢ ' (6)EXISTING VERIZON ANTENNAS TO BE REMOVED �i J j — 3 LLINGWOSADDLEBRTH, DRIVE PHONE(660)E6&1697
' •� ' Q (3)NEW RACK - ADD(3)NEW WALL KIWWALLORTH,CT06419 FAX(660)E630935
jI 4 WMWALLPOINTSTECH COM
MOUNTED A-2 MOUNTED MDBS U
EXIST 90'HIGH UNIPOLE I i LTE-C RRHs A_2 — w
APPROVALS
LOCATION MAP EXIST WHIPANTENNAS(TYP) Z (3) MOUNTED A2 MOD AWS y0 Q
I Q BBU/ J 0: it LANDLORD DATE
Z PCS-LTE RRHs Q RF ENGINEER GATE
SCALE:1"=100'-0" EXIST LATTICE
TO 2
(3)NEW RACK
ZZZ MOUNTED 4 w CONSTRUCTION DOCUMENTS
EXIST VER120N 11'-67c30'(345s SFS EQUIPMENT I jl AWS RRHs q-2 UF r� O m O NO DATE REVISION
SHELTER W/DIESEL-POWERED GENERATOR,(3)GPS 3 Q N Q >4> RECT J 0 10/31/14 FOR RENEW SPM
STRUCTURAL NOTE UNITS ADD(3)WALL MOUNTED MDBS&(9)RACK q_7 I +I w H S DESK GPS BATTERY RACK w
PLEASE REFER TO STRUCTURAL MOUNTED RRHs WITHIN SHELTER iO > m 2424 ~ 1 11/06/14 FOR FILING SPM
IOIi
ANALYSIS COMPLETED OTHERS I Z 2 1/26117 FORREVIEW SPM
w EXIST GPS UNIT W/ 3
AVAILABLE UNDER SEPARATE COVER EXIST FIRE HOUSE ZOZ 5 3 LINE(TYP 3 PL) -L
—
MAIN ROAD EXIST IRREGULARLY SHAPED 6'TALL I m U Z 5
(BEYOND) CHAIN LINK FENCED COMPOUND I wZ 5 7 6
o EQUIPMENT SHELTER
EXIST FIRE HOUSE EXIST FIRE HOUSE I > Z a7a
U U W
�Z Z
y w
EXIST LATTICE TOWER OU
W Z
EXIST VERIZON 11'-6'x30'(345x SF) § Z
EQUIPMENT SHELTER W/DIESEL-POWERED 3 I 8 U
GENERATOR,(3)GPS UNITS ADD(3)WALL PARKING LOT I Z H
MOUNTED MDBS&(9)RACK MOUNTED A-1 0 m
RRHs WITHIN SHELTER H O i w 6 4-Lines 2-Antennas
x \ 1 _z°a > 4-Diplexer—2 Quadplexer—2 7Yiplexer
N
EXIST VERIZON CABLE TRAY W/(12) i �0 x ------------- N
REPLACEMENT 7/'COAX CABLES - ------------
O_ _ ? DESIGN PROFESSIONALS OF RECORD
O ANTENNAS(60'.190'.(60'EX190°,282°)MOUNTED -,,,282-
X\ GY= X� U 1 o>igL�xr" ouniiv"J 1
/ � i PROF SCOTT M CHASSE P.E
2z ( _ COMP APTENGINEERING
O WITHIN EXIST IST HIGH CABLES 4,5 - °; 6i 1_\f %I ADD 3 SADDLEBROOK DRIVE
O REPLACE EXIST COAX CABLES q_7 q_p :c�-a y'C* t\ 3 SAD GWOROO CT DRIVE
ID(O RELOCATE ANTENNAS TO TOP o:�...t; %1 �
F CONCEALMENT CYLINDER (`,RADE �Al AZ I
EXIST 90'HIGH UNIPOLE x x 1016'2 AMSL l/ `,1 l ? OWNER AMERICAN TOWER
— — — — !a= SOUTLE H ELEVATION ° _ �l CORPORATION
EXIST MULTIMETER CENTER 190° F—x SCALE:1"=10'-0" ^ TOP AMPHENOL x
Al s e
EXIST AT&T (IN FEET)1 cch= 10 R O CWX6 7 LB G00 / , i T
26 7 LBS I NOTE
x PAD MOUNTED 7P p° 4 26 SF ITIS
A VIOLATION OF NEW YORK STATE
EQUIPMENT x ) EDUCATION LAW ARTICLE 145,SECTION
EXIST&HIGH CHAIN LINK FENCE(TYP) FRONT SIDE # ---— 7209(2)FOR ANY PERSON,UNLESS
X X — —) ACTING UNDER THE DIRECTION OF A
" 3 LANDSURVEEER
YOOR,TOALTERANLICENSED IITEM INR
EXIST CSC CABINET I ANY WAY IF AN ITEM BEARING THE SEAL
7ACBBPA 7ACfiBPA 7AC9BPA 7AOB9PA
OF AN ENGINEER OR LAND SURVEYOR IS
EXIST PAD MOUNTED TRANSFORMER
Ise ALTERED,THE ALTERING ENGINEER OR
1 u: in 3 LAND SURVEYOR SHALL AFFIX O THE
l ITEM HIS SEAL AND THE NOTATION
A-1 1 'ALTERED BY"FOLLOWED BY THESIGNATURE AND THE _
j
ALTERATION,ANDA PECEFOCF SUCH
DESCRIPTION OF THE ALTERATION
7
K11COMPOUND PLAN LlF VERIZON AT
(IN FEET)1lnch= 10 It 120° 71° "ORIENT"
- - — — — — — —•—•— —•— — —•— — — — — I SITE 23300 MAIN ROAD
PANEL ANTENNA ) 1 ADDRESS 11957
SECTOR
SECTOR ALPHA BETA GAMMA DELTA EPSILON ZETA NOTES ; A-0 APT FILING NUMBER NY141PCS1590
BASE COLOR WHITE BLUE GREEN WHITE/SLK STRIPE WHTE/RED STRIPE WHITE/GRN STRIPE (1) CONTRACTOR SHALL PROVIDE MECHANICAL DOWNTILT BRACKETS �ANTEN NA DETAIL OUAOPIE%ER OUPOPIEYER )
850-CELL GRAY GRAY GRAY GRAY GRAY GRAY (2) CONTRACTOR TO FIELD VERIFY ALL CABLE LENGTHS PRIOR TO ORDERING NEW CABLE(TYP EACH SECTOR) 7ACBBPA 7AC8BPA I
PCS-EVDO PURPLE PURPLE PURPLE PURPLE PURPLE PURPLE (3) VERIFY CABLE DIAMETER WITH VERIZON PRIOR TO ORDERING A-1 SCALE Yp"=1'-0" I ) PROJECT CODE 20161327697
700 LTE RED RED RED RED RED RED (4) CONTRACTOR SHALL CONFIRM GPS UNIT MODEL AND CABLE WITH VERIZON _ _ 3 LOCATION CODE 157730
850-LTE LIGHT GREEN LIGHT GREEN LIGHT GREEN LIGHT GREEN LIGHT GREEN LIGHT GREEN (5) CONTRACTOR SHALL INSTALL WEATHERPROOF CAPS ON ALL UNUSED PORTS,SWEEP TEST THE UNUSED I 1 • )
AWS-LTE YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW PORTS/ANTENNAS,AND PROVIDE RESULTS IN SWEEPS PACKAGE
PCS LTE LIGHT BLUE LIGHT BLUE LIGHT BLUE LIGHT BLUE LIGHT BLUE LIGHT BLUE
GPS BROWN
_ DATE 10/31114 CHECKED BY.SPM
ANTENNA DATA
EXISTING ANTENNA SPECIFICATIONS NEW ANTENNA SPECIFICATIONS
SECTOR MODEL p7Y EM
D-TILT D ILT STATUS STATUS LENGTH
- - ANTENNA CABLE CABLE AZIMUTH SECTOR MODEL Q7y E- M- ANTENNA CABLE CABLE AZIMUTH
-TILT D-TILT STATUS STATUS LENGTH i0�. SHE /
-TD �� • 1_/////
ALPHA ALPS 5 ANTENNA CABLING DIAGRAM ��� `� m /®
CELL X70-480(UPPER) 1 0° O° REPLACE (4) CELULTE-C/PCS-LTFJAWS CWX063X13G00 t 2°LTE-C 0° NEW REPLACE(4) PL ^ LEVAT
COAX 92'2 90° 130'± 60°
PCS/-TE-C X70AP-480-I(LOWER) 1 0° 0° REPLACE CABLES LTE-C/PCS-LTFJAWS CWX063Xt3G00 1 2°LTE-C 0° NEW COAX CABLES A-� SCALE:NTS
NA- rA{I
BETA BETA ]
CELL X70-480(UPPER) 1 0° 0° REPLACE CELLJLTE-C/PCS-LTE/AWS CWX063X73G00 1 4°LTE-C 0° NEW REPLACE(4)
PCS/LTE-C X7CAP-480-1(LOWER) 1 0° 0° REPLACE BLECOAX 92'z 210° LTE-C/PCS-LTE/AWS CWX063X73G00 1 4°LTE-C 0° NEW COAX CABLES 130'2 190°
CABLES
GAMMA GAMMA
CELL X7C-480(UPPER) 1 D° D. REPLACE (4)%' CELL/LTE-C/PCS-LTE/AWS CWXO63X13GOO 1 4°LB 0° NEW REPLACE(4)
P_S/LTE-C X7CAP-480-I(LOWER) 1 O° 0' REPLACE COAX 92'2 330' LTE-C/PCS-LTFJAWS CWX063X13G00 1 4°LB 0° NEW COAX CASLES 130'2 282°
CABLES
GPS POTEL GPS-TMG-HR-26N 3 - - REMAIN (1)2 i& 16'2 N/A GPS - - - - - - - - �F/���/In, 1��" ✓,,7��",\\
verizonJ
4 CENTEROCK ROAD
WEST NYACK,NY 10994
EXIST UNIPOLE APT
INTERNAL ANTENNA 4 (3)NEW VERIZON PANEL ENGINEERING
MOUNTING PIPE A_7 ANTENNAS(UPPER TIER)
4 EXIST UNIPO U INTERNAL
NEW VERIZON ANTENNA,NP OF(6) NOTE 3 LLI GLE8800 CT064 PHONEFAX(66O)-ce3-1697
p-1 ANTENNA MOUNTING PIPE
1)RRH=REMOTE RADIO HEAD VMWAWORTH 0706419 FAX(660)663-0935
2)MDB=MAIN DISTRIBUTION BOX NnnivVALLP01N76TECH COM
APPROVALS
y2, LANDLORD DATE
�\o RF ENGINEER DATE
(CELLILTE-C/PCS-LTE/AWS)UPPER % IX= RF TRANSPARENT (6)NEW DIPLIXERS ° i
(LTE-C/PCS-LTE/AWS)LOWER
60° RADOME� I N O c n• o CONSTRUCTION DOCUMENTS
EXIST 90'-0'x HIGH �^ J
m NO DATE REVISION
1 (CELL�LTE-C/PCS-LTE/AWS)UPPER I 4 (3)NEW VERIZON PANEL 15 T 0 10TJ1114 FOR REVIEW SPM
UN POLE °o (LTE-C/PCS-LTE/AWS)LOWER
III I q_I ANTENNAS(LOWER TIER) 1 11/06/14 FOR FILING SPM
BOTTOM 2 1Y16H7 FOR REVIEW SPM
(12)NEW DIPLIXERS4
(CELL/LTE-C(PCS-LTE/AWS)UPPER " BELOW ANTENNAS 15 7' MAR
DISTRIBUTION PBOX(MOB) 5
(LTE-C/PCS-LTE(AWS)LOWER WXDXH=15 73X1025'x19 18°(32 O Lbs) g
a- EXIST ANTENNA FRONT (OR EQUAL)
190e/ EXIST COAX(IYP) HOUSING ASSEMBLY -
` (6)NEW DIPLEXERS
AMAIN DISTRIBUTION BOX
ANTENNA MOUNTING PLAN A_2 SCALE V-V-D"
t A-2 SCALE r"=V-0" (!: ANTENNA MOUNTING DETAIL
A-2 SCALE:Ys"=1'-0"
DESIGN PROFESSIONALS OF RECORD
FI
SCOTTM CHASSE PE
P APT ENGINEERING
3 SADDLEBROOK DRIVE
KILLINGWORTH,CT 06419
TOP OF SHELTER OWNER AMERICANTOWER
CORPORATION
CABLE TRAY HUNG FROM SHELTER CEILING
(SHOWN FOR REFERENCE ONLY)
NOTE
EXISTING CABLE PORT(SEALED NOTES IT IS A VIOLATION OF NEW YORK STATE
WEATHERPROOF BY CONTRACTOR) Onn�®O EXTEND TWO(2)3-EMT CONDUITS 1 ALL RAYCAP MAIN DISTRIBUTION BOXES SHALL EDUCATION LAW ARTICLE 145,SECTION
FROM TOP OF TROUGH ON INTERIOR BE MOUNTED AT 48'A F F MEASURED AT THE 7209(2)FOR ANY PERSON,UNLESS
WALLAND TERMINATE AT SHELTER CENTER OF THE UNIT NO OBSTRUCTIONS ACTING UNDER THE DIRECTION OFA
OO�OO® CEILING MOUNTED CABLE TRAY DIRECTLYABOVE THE DISTRIBUTION BOX SO LICENSED PROFESSIONAL ENGINEER OR
THAT THE COVER CAN BE REMOVED LAND SURVEYOR,TO ALTER AN ITEM IN
SHELTER INTERIOR WALL '�N®O O O 2 ALL UNISTRUT(1-5/8'DEEP)SHALL BE SIZED TO ANY WAY IF AN ITEM BEARING THE SEAL
ACCOMMODATE BOTH CONDUIT INSTALLS,12' OF AN ENGINEER OR LAND SURVEYOR IS
FRONT SIDE TOP FRONT SIDE TOP FRONT SIDE TOP MINIMUM ALTERED,THE ALTERING ENGINEER OR
NEW RAYCAP MAIN 3LI J CONTRACTOR PROVIDED AND INSTALLED 3 ALL HARDWARE SHALL BE STAINLESS STEEL LAND SURVEYOR SHALL AFFIX TO THE
N n � DISTRIBUTION BOX MOUNTED TO (NEMA 1)10°X70'X18"TROUGH MOUNTED 4 ALL INDOOR CONDUIT SHALL BE EMT ITEM HIS SEAL AND THE NOTATION
10�
) SHELTERINTERIORWALLTYP A_2ONSHELTER WALL 5 THE TROUGH ABOVE THE DISTRIBUTION BOX "ALTERED BY"FOLLOWED BY THE
o m 11 8' 12' 11 EXFEND THREE 3 3'EMT CONDUITS FROM SHALL H BELOW THE'NEMA1 CLASS THE SIGNATURE,AND A GATE IC SUCH
� � O TROUGH BELOW THE DISTRIBUTION BOX SHALL ALTERATION,AND A SPECIFICTOP INTROUGH ON INTERIOR WALL Ai�l III BE 10'X10'X6'NEMA 1 CLASS DESCRIPTION OF THE ALTERATION
TERMINATE A7 BOTTOM OF UPPER TROUGH 6 REMOVE TWO(2)2-12'BLACK HYBRIFLEX
11 8° 7 5' 12° 7 2° 6' 6' 6' CABLE COMPRESSION FITTINGS SUPPLIED WITH VERIZON AT
1 t 8' 17 2'I THE RAYCAP BOX AND INSTALL TWO(2)2-12'
F—# EMT CONNECTORS AND BUSHINGS BETWEEN "ORIENT"
ALCATEL LUCENT B13 RRH(OR EQUAL) ALCATEL LUCENT B25 RRH(OR EQUAL) ALCATEL LUCENT 8666 RRH(OR EQUAL) PROVIDE TWO(2)2-12°GRS NIPPLES AND THE RAYCAP BOX AND THE TOP TROUGH SITE 233DO MAIN ROAD
RRH 2x6OW 700 LTE-C RRH 2x6OW POS RRH 2x9oW AWS MYERS HUBS BETWEEN THE RAYCAP BOX 7 EXTEND 02AWG INSULATED,STRANDED,
REMOTE RADIO HEAD(RRH) REMOTE RADIO HEAD(RRH) REMOTE RADIO HEAD(gRFO m AND THE TOP OFTHE EXTERIOR TROUGH COPPER CONDUCTOR,BOLTED FROM BASE ADDRESS ORIENT,NY 11957
WxDXH=11 8X7 5X20 9-(55 5 Lbs) WXDXH=12 0X7 2X21 4'(51 0 Lbs) WXDXH=11 8X7 27(25 S'(56 8 Lbs) '� AND BOND TO SHELTER CORNER EXIT GROUND APT FILING NUMBER NYIM PCS1590
a CONTRACTOR PROVIDED AND INSTALLED a PULL STRING SHALL BE TERMINATED INSIDE OF
NOTES 1,-O, (NEMA 1)1 O'X1 O'X6'-O'TROUGH MOUNTED SHELTER AND TROUGH BOX FOR ALU USE PROJECT CODE 20161327697
1 DIMENSIONS SUBJECT TO CHANGE BASED UPON AVAILABILITY ATTIME OF CONSTRUCTION ON SHELTER WALL
2 MANUFACTURER'S RECOMMENDED RRH CLEARANCES FRONT 36',SIDES 12',BOTTOM 24• LOCATION CODE 157730
3 SFPS ARE PROTOCOL SPECIFIC THE CONNECTIONS BETWEEN RRHs AND BBUs ARE CPR] EXTEND#2AWG INSULATED,STRANDED,
CONNECTIONS,AND REQUIRE CPRI SFP(ON BOTH ENDS)THE CONNECTIONS BETWEEN COPPER CONDUCTOR AND BOND TO VZ CM PKM DRAWN BY. CSH
SHELTER CORNER EXIT GROUND
BBUs AND 7705 ARE ETHERNET AND REQUIRE ETHERNET SFP(ON BOTH ENDS) DATE 10/31114 CHECKED BY SPM
RRH EQUIPMENT ELEVATION-INTERIOR
A-2 SCALE Y;•=1•-0" r51MDB MOUNTING DETAIL @ SHELTER INTERIOR
A_2 SCALE:NTS
TLE' h
IF A MIl� N,G
p T D ILaS 6
m all
H E BER"
FEg S 'tA '
DESIGN BASIS SUBMIRALS ANCHORS DEMOLITIONSPEORC NANDNOTESCONT SNE GENERAL CONT
CODES I CONTRACTOR TO SUBMIT SHOP DRAWNGSPRCRTO IXPANSIONANCHORS SHALL BE USED WHERE ATTACHING TO CONOUCTDEMOLTON OPERATIONS AND REMOVE DEBRIS TO ALL EXIST INACTIVE SEWER,WATER,GAS ELECTRIC,FIBER OPTIC,
• 20106MLDING CODEOFNEW YORK STATE FABRICATONTO ENGINEER FORREMEW CONCRETE MASONRY MOUNTS SHALL HAVEINJETONADHESNE ENSURE MINIMUMINTERFERENCE WITH ADJACENT AREAS OTHER OR OTHER UTILITIES Wr11C1'11NTERFERE WITH THEEXECUTOry OF ���'���
• TIAjB 22-FRe STANDARD 2 ALLBULLDINGCONNECTIONPOINTSARETOBECEMERED ANCHORING OCOURE AREAS,COMMON AREAS THROUGHOUT BUILDING, THE WORK SHALL BE REMOVED,ANDIORlg WUPLUGGED OR
OVER BEARING WALLS WALKWAYS PARIAHS LOTS,AND ROADWAYS OTHERWISE DISGONIINUED AT HINTSWIHCR WILL NOTINTEREEE
DESIGN CRITERIA 3
NOTIFY ENGINEER FOR INSPECTION PRIOR TO CLOSING EXPANSION BOLTS SHALL BE HLLT KINK BOLT 30q APPROVED WTTHTHE EXECUTION OF THE WORK SLBJECTTO THE APPROVAL
BASIC WIND SPEEDM-BS MPH(FASTEST MILE) PENETHATONS ENTAL MINIMUM EMBEMEM4INCHES CONOT CLOSE OROBSTRUCT STREET$,WALKS OR OTHER OF THE( NSTRUpONMANAGER
EQUNALENTTO 100 MPH(3-SECOND GUST) ADJACENT OCCUPIED OR USED AREAS WITHOUT PERMISSION
BASICWNDSPEEDM-14MPH(FASTESTMILE) CONTRACTORS SMALL VERIFYALL DIMENSIONSANDCONDTIONS INJECTONADHESNEANCHORINGINMASONRYWTMVGDSSHALL FROMOWNER IFREQU%D,PROMDEFORALTERNATEROUTES CONTRACTOR IS RESPONSIBLE FOR REPAIRNG OR REPLACING 4 CENTEROCK ROAD
CONOURENTW/05 PADIALICE INTHE FlELDPRORTOFABRCATONANDERECTONOFANY BEKLOHITHY-TOOREQUALWITHT-6iEAME ANDSG EN AROUND CLOSED OR OBSTRUCTED TRAFFIC WAYS STRUCTURES OR UTLITES DAMAGED By HOS OPERATIONS LDI-frRI-/QUADPLEXERS,
I I NEWANTENNAS COORDINATE QUANTITY,
MATERIAL OIEENGINEERSHAL.BE-TIFEDOFANYCONDTIONS TUBES TO THE FOLLOWNG BASE MATERIALS ANTENNA CABLING DIAGRAM, I I EXACT MAKE&MODEL WITH VERIZON WEST NYACK,NY 10994
WHICH PRECLUDE COMPLETON OF THE WORK N ACCORDANCE CONDUCTDEMOUTIONOPERATONSMMEVENTINJURYTO CONTRACTOR SHALLPPOTET EXIST PAVED ANO GRAVEL I I
WITH TIE CONTRACT DOCUMENTS BRCK WTI HOLES PEOPLE AND DAMAGE TO ADJACENTMEAS BUILDINGS AND/OR SURFACES CURBS LANDSCAPE AND STRUCTURES AND RESTORE ANTITY OF ANTENNAS,CABLES,
SPACEANCHORS2COMPLETEBRCKSAPARTMINIMUM FACILITES TOREMAN ENSURESAFEPASSAGEOFPEOPLE SITE TOPE-CONSTRUCTIONOONDMONWNHASGOOD OR MAIN DISTRIBUTION BOXESDESONAND CONSTRUCTONOF UCTURALSTEEI.SHALL MAWAIN 2 COMPLETE BROKS OR 16 INCHES AROUND DEMDUTION AREAS BETTER MATERIALS NEW MATERIALS SHALL MATCH EXISTWNFORMMI_ATESTEIiONOFTHEAMERCANINSTUTEOF FROMFEEEOGESWHICHEVETISLESS) THICKNESSANDTYPE OTE RADIO HEADS(RRHS) I I
STEEL CONSTRUCTON SPECIFIGATON FOR THE EMBEDMEWG-1/t INCES MINIMUM PROMDEANDMAINTAININTERIORANDEXTERIORSHORING, YzO COAX JUMPER CABLES TO ANTENNA(FROM
DESIGN FABRICATION AND EECTON OF STRUCTURAL STEEL FOR BRACING OR STRUCTURAL SUPPORTTO PRESERVE STABILITY AND THE CONTRACTOR SHALL SHORE ALL TRENCH EXCAVATON
BUILDINGS HCU.WCANCREZEELOCK PREVENTMOVEMENT SETTLEMENT ORCOLLAPSEOF GREATERTHAN 5FEETNDEPTI0RLESSWHERESOILCONOITONS j j DI-/TRI/QUAOPLEXER OR RRH)COORDINATE APT
USE 50%MORE ANCHORS THAN SHOWNIN DETAIL PERPHERALSTRUCTUESANO/ORAREAS AREDEEME UNSTABLEALLSHEETIT
NGANDORSHORING I I QUANTITY,EXACT MAKE MODEL WITH VERIZON
STRUCTURAL CONNECTION BOLTS SHALL CONFORM TO ASTM SPACING ONE ANCHOR MAXIMUM PER BLOCK CELL METHODS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER I I ENGINEERING
A325 ALL BOLTS SHALL BE 3/4 DIAMETER MINIMUM AND SHALL MAINTAIN 12 SPACING FROM FREE EDGES DO NOTCREATE HAZARDOUS OR OBJECTIONABLE COMMONS.
HAVE MIN OF TWO BOLTS,UNLESS NOTED OTHERWISE ON THE EMBEDMENT THROUGH FACE SUCH AS ICE FLOODING AND POLLUTION,WHEN USING WATER THE CONTRACTOR IS RESPONSIBLE FOR MANAGING DI-/TRI/QUADPLEXER(T1YP)
DRAWNGS LOCKWASHERSARENOTPETMTTTEDFORA3253IEEL GROUNDWATERLEVELSIN TIEMCINRYOFIXCAVATONSIO COORDINATE QUANTITY,EXACT 3SADDLEBROOKDRIVE PHONE(860}6631697
ASSEMBLIES INJECTION ADHESIVE ANCHORNG IN SOLID MASONRY AND GROUT REMOVE AND TRANSPOWDEBRISINAMANNERTHATWLL PROTECTADIACENTROPERTESANDNEWWORK (TYPO CONSULT 3SADGNDROOKDRIIVE FAX*
(860683-0935
FlLLEDBLOCKS BEHILTHRHY-2000REQUlLL PREVENT SPILLAGE ON ADJACENT SURFACES AND AREAS GROUNDWATERSHALLBEDRAINENACCORDANCEWIMLOCAL MAKE&MODEL WITH VERIZON COAX CABLE ( )
NON-STRUCTURALCONNECTONS FOR STEM-GRATING MAYUSE THREADED ROD MAINTAIN 12 NCHES BETWEEN ANCHORS AND SEDIMENTATION B EROSON CONTROL GUIDEUNES RFOS FOR APPLICATION IVWVWALLPOINTSTECH COM
5/S DIAMETER GALVANIZED ASTM A.1 BOLTS UNLESS ALL FREE EDGES MINIMUM SPACING BETWEEN ANGORS IS B CLEAN ADJACENT AREAS AND IMPROVEMENTS OF DUST,DIRT AND
OTHERWISE NOTED INCE$ DEBRIS CAUSED BY DEMOLTCN OPERATIONS RETURNADJACENT CABLE TRAY APPROVALS
AREAS TO CONDITION EAST BEFORE STARTOG DEMOLITION ANTENNAS
ALL STEEL MATERIAL EXPOSED TO WEATHER SHALL BE ANCHORS SHALL BE INSTALLED PER MANUFACTURERS CABLE TRAY SHALL BE MADE OF EITHER CORROSION RESISTANT
GALVANIZED AFTER FABRICATION IN ACCORDANCE WIMASTM RECO MMENDATONSANDSHALLNOTBEINSTALLEDINMORTAR USE METHODS REQUIRED TO COMPLETE DEMOLNION WITHIN METAL OR WITH A CORROSION RESISTANT FNISHL EQUIPMENT SHELTER LANDLORD DATE
A123ZNC(HOT-0IPPED GALVANIZED)COATINGS ON IRON AND JOINTS UMITATONS OF GOVERNING REGULATIONS
STEEL PRODUCTS CABLE TRAY SHALL BE OF LADDER TRAY TYPE WITH MATCOVER DI-/TRI/QUADPLEXER(TYP) REMOTE RADIO HEAD(RRH)(lYP)COORDINATE RF ENGINEER DATE
HALL
GRATING SBE ATTACHED USING FOUR GRATING CLAMPS OR LOCATE DEMOLITION EOUIPMENTTHROUGHCITT THE BUILDING AND CLAM PED TO SIDE RAILS
ALL BOLTS,ANGORS AND MUSCELUANEOUS HARDWARE EXPOSED X FlLLETWELDSPERSET10N REMOVE DEBRISBMATEHIALSEASNOTTOIMPOSEEXCESSNE COORDINATE QUANTITY,EXACT QUANTITY,EXACT MAKE&MODEL WITH VERIZON
TO WEATHER SHALL BE GALVANIZED INACCORDANCEWTHASTM LOADS ON SUPPORTING WALLS,FLOORS OR FRAMING CABLE LAD DER SHALL BE SIZED TO FIT ALL CABLES N ACCORD MAKE&MODEL WITH VERIZON CONSTRUCTION DOCUMENTS
A15 14CCOATING(HOT-DIP)ON IRONANOSTEELHARDWARE ELECTRICAL WITHNECANONEMA II-1554
DISPOSEOFDEIVOUSHEOITEMSANOMATERALSPROMPRY NO DATE REVISION
CAMAGE GALVAMZED SURFACES SHALL BE REPAIRED BY CONTRACTOR SHALL VERIFY EAST ELECTRO SERVICE TYPE AND ONSITE STORAGE OR SALE OF REMOVED ITEMS IS PROHIBITED CABLE LADDER TRAYS SHALLBE NEMA CLASS 12A BY PW
TOUCHING UP ALL DAMAGED GALVANIZED STEEL WITH GOLD—C CAPACTYANOCROERNEWELECTRIISERMCEFROMLOCAL INDUSTRIES INC OREUAL RRH RRH RRH 0 10131/14 FORREVIEW SPM
OALVANOIC,DRY GALA',n 1,OR APPROVED EOUNALENT IN ELECTRIC UTILITY,WHERE APPUCABLE DEMOLISH CONCRETE AND MASONRY IN SMALL SECTIONS
ACCORDANCE WITH MANUFACTURERS GUIDEUNES UCH UP CABLE LADDER TRAY SHALL BE SUPPORTED IN ACCORDANCE WITH G G G
WTO1 11/06/14 FOR FILING SPM
DAMAGENONGALVANIZBJS MWTISN,4EP WAPPLtEDIN ALLELETRICALWORKSHALLBEINAOCCRDWNHALL PATCH TO PRODUCE SUITABLE SURFACES FOR NEW MATERIALS MANUFACTURERS SPECIFICATIONS 1/26/17 FOR REVIEW SPM
SHOP OR FIELD APPL!CABLECOOES ANDSHALLBEACOEPTABIETOALL WHEN REPAIRING EXIST SURFACES
AUTHORTESHAVINGJURSDICTON WHERE ACONFLCT EXISTS ALL WORKNA,NSRP SHALL CONFORM TO THESE REQUIREMENTS 3
CONTRACAAPPPEARANCE ANDOLUAALLI�OF WELDS AND WELDIY WITH AWS CO E FOR NG PROCESSES HA NOJURISDICTIONRITHE MOREAND
SPECSIRINGENT AOR AUTHORITIES �D UTHORITIES SHALL AD DINING CONSTRUSTORED CTIONN A MANNER THAT ELIMINATESMSED FINISHES OF PATCH $INTO AN ADEQUATE GROUNDING SYSTEM OAROS TO ENSUE SPFEAND 4
SHALL BE QUALIFIED IN ACCORDANCE WITH AWS STANDARD APPLY EVIDENCE OF PATCHING AND RESURFACING 5
QUALIFICATIONPROCEDURES.ALLWELONOSHALLBEDONE ANTENNABCABI.ENOTES
GENERAL CONDITIONS USING E70A(ElL-CTROCESANOWELDINGSHALLCONFORMTO CONTRACTOR SHALL PROVIDE ALL LABOR MATERIALS DONGTBURNOEMOUSHEDMATERIALS HELIAX FIBERFEED HYBRID JUMPER CABLE 6
NSCANDDII WHEREFILLETWELDSIZESARENOTSHOWN, INSURANCE,EUIPMEW INSTALLATION,CONSTRUCTION TOOLS THECONTRACTORSHALLFURNISHANDINSTALLALL ASSEMBLY,(2)PAIR POWER CONDUCTORS,(4)
RISTIE CONTRACTORS SOLE RESPONSIBILITYN COMPLY WITH PROVOETHEMINMUMSIMPERTABLEJ241NTHEAISC'MANUAL TRANSPORTATION,ETC,FOR A COMPLETE AND PROPERLY TRANSPORT DIMATERIALS OFF OWNERS PROPERTY TRANSMISSION CABLES,JUMPERS CONNECTORS GR.UNDINO
ALL APPLICABLE FEDERSTATE AND LOCAL BUILDING CODES OF STEEL CONSTRUCTION 13TH EDITION ATTHE COMPLETION OF OPERATIVE SYSTEM ENERGIZE THROUGHOUT AND AS INOICATED ANDLEGALLYDISPOSEOFTHEM STRAPS ANTEN
AL, NAS
MOUWAND HARDWARE ALLMATMIALS FIBER,MODEL#RFA412-4SXX-XX BY ANDREW
PERMNCONDITONSANO SAFETYCODELL GALVANIZED
S DURNGOONSTRUCTON WELDING ADAMAGE TO COATING SHALL BE ONTHEDRAWNGSANOASSPECIFIEDHERBNAND/OROTHFRWISE SHALL BEINSPECIED BATHED CONTRACTOR FOR DAMAGE UPON SOLUTIONS OR EQUAL COORDINATE QUANTITY,
REPAIRED SEE NOTE ABOE REQUIRED PROMPTLY�UBMNAWR(TTENRENRTTOTHEENGINEETSHOULD OELNERY JUMPERS SHALL BE SUPPLIED ATANTENNAS AND EXACT MAKE&MODEL WITH VERIZON
THE ENGINEER IS NOT AGUARANTDR OF THE INSTALLING UNANTGPATED STilCR1RPI ELECTRICAL,OR MECHANICAL EQUIPMENT INSIDE SHELTER COORDINATE LENGTH OF JUMPER
CON TRACTORS WORK,RESPONSIBLE FORTHE INS LINOR THE ENGINEER SHALL BE NOTIFIED OF ANY INCORRECTLY ALL ELECTRICAL CONDUCTORS SMALL BE 10096 COPPER AND CONORCNS 5ENCOUNTERED THE SUBMTTED REPORT SHALL GABLES WTH VERIZON COORDINATE AND VERIFY ALL OF THE
AS UTTTHEWORKSITE,INCONTROLOFTHESAFEW ORAD
FASRCATED,DAMAGED OROTHERWSEMISR—GOR SHALL HAVE TYPE TIHN INSULATION UNLESS INDICATED INCLUDESUFFlGEWDETNI-REGAROINGTHEEXTENTANDNATURE MATERIALS TO BE PROVIOEO WITH VERIZON PRIOR TO SUBMTTING
NONCONFORMING MATERIALS OR CONDITIONS TO REMEDIAL OR OTHERWISE OFTHECONOMON BID AND ORDERING MATERIALS
OF RK BUILDING COMPONENT,SCAFFOLDING GROTTIER RELATED ANTENNA CABLE GROUND KIT(TVP)
WORK AIDS OR]RESPONSIBLE FOR SUPERINTENOINGTHE WORK COREECTVEACTION ANY SUCH ACTION SHW1REpUlE
ENGINEER REVIEW CONDUIT SHALL CO RE.SOADEDRGOPLINGE AND
CONNECTEEL OR TORS,
THE NORMAL HOSTRUCTA WOBKSMALLBE UNITED TO AFTER INSTALLATIONEPTESDFOR PRANSMISGON LINE TALATIONA AND DEM AMAGE a¢ W 0
WTMACEUPWPRESSION TYPE COUPLINpSAND CONECTORS, THE NORMAL HOURS OF SAM TO BPM RM/SWEEPTESIED FOR PROPER INSTALLATION AND DAMAGE OO G GROUND WIRE CONNECTED TO EXIST
THECONTRACTORTESING AND CSIBLE FOR PROVIDED ALL PERMITS H i0
CONTRACTOR LNG CQNVE AND RE-INSTALL ALL FIREPROOFING ASI ALL MAOEUP WRENCH TGHi WITIHANTENNgSCOES FROM CONTRACJ0RTO OBTAIN LATEST
INSPECTIONS TESTING AND CERTIFICATES NEEDED FOR LEGAL �N § N Q MASTER GROUND BAR
OCCUPANCY OF ll-E FINISHED PROJECT
REQUIRED WRING CONSTRUCTION AREAS DURING
EMOUTIRfiYTDADJACEW ANO COMMON TESTING PROCEDURES FROM VERZON PROgTO BIDDING S
PROV,UI FLEXIBLESTEEL GEQUlpONDUIT ENT INCUL0INFHVACESTS, AREASSOURZE OERSONSF ACTMTIERIN PREVENT
THECONTPACTOgIS RESPONSIBLE 1b REVIEW THOS COMPLETE CESGN,FABRCATO CAND URRENT
NOF CAN INSCTURALSIEEL CONCUR TOALL MBRATNG EO,ORWHEREEQDINO HVAC UNITS, UNAUTNOR12ID PERSONS FROM ENTERING THE SITE ANTENNA CABLES STALL BE COLOR CODED ATTIRE FOLLOWING - m Q G
PLAN SETAND VERFY THE EXIST CONDITONS SHO WN IN THESE $HALL CONFORM TO CURER AMERICAN INSTINIE OF STEEL TRANSFORMERS,MOTORS,EIC,OR WHERE EQUIPMENT IS PLACED LOCATIONS ______ O O O
PLANS AS THEY RELATE TO HIS WORK PRIOR TO SUBMTTNG PRICE CONSTRUCTION SPECIFICATIONS UPONASlAO ON GRADED DUE CPRE SHALL BE TAKEN SO OIAT THE EQUIPMENT - ATTIRE AUNTENNAS / \1- H H
SIGNIFCANT DEVIATIONS FROM WHAT IS SHOWN AFFECTING THE AND ITS INSIALLAON ARE HANDLED IN A MANNER THAT - ATTHE WAVE GUARD ENTRY PLATE ETH SIDES OF THE l MASTER GROUND BAR AT
WOW SHALL BE REPORTED IMMEDNTELY TO THE CONSTRUCTION THE STEEL STRUCTURE IS DESIGNED TO BE SELSPO
FUPRTNG AND ALL BRANCH CIRCUITS AND FEEDERS SHALL HAVE A SEPARATE WILL NOT AFFECT FIRE SAFETY OR CREATE A FIRE HAZARD EQUIP SHELTERWALL
MANAGER SI'ABLEAFTEq COMPLETION RISTHEGONTRACTORSWLE GREENNSULATWEDUIPMEWGROUNOIWMNDUMRENDM - JUMPERCABLESATTI-EEUIPMENTENTER EQUIPMENTSPACE
RE SPONSBILRYTODETERMNEMECTONPROCEOUREANO TO ALL ENCLOSURES,PULLBOXES,ETC GROUNDING I I MOB
DETAILS INCLUDED IN THIS PLAN SETARE TYPICAL AND APPLY N SEQUENCE AND TO INSURE THE SAFETY OF THE BUILDING AND ITS MATERIALS SYSTEM INSTALLATION
SIMILARCONDMONS COMPONENTPARTSDURNGEECTON MIN UITANDCABLEWRHINCORROORSSHALLBECONCEALED THE CONTRACTOR SHALL INSTALL ALL CABLES AND ANTENNAS TO I
AND EXPOSED ELSEWHERE,U O N f6 THWN SHALL BE STRANDED f6 COPPER 14TH GREEN OHWN THE MANUFACNRERS ArvD VER ZONSSPEGFlCATIONSTHE I 9926 BBU,POWER \ _
EAST ELECTRICALANDMECHAWICALFIXRURES PIPING WRING TO SHO PIORAWETO
NGSABECEGO=DBYTHE00NIHACTORAND INSULATONSUITABLEFORWETINSTALLATIONS CONTRACTORISESMN315LEFORTHEPROWREMEWANO EONPMENT
DISTRIBUTION PANEL(FOR LEGACY G \
SUBMITTED THE ENGINEER FOR APPROVAL PRIOR TO EIFCTRICAL MATERIALS INSTALLED ON ROOFTOP SHALL BE LISTED INSTALLATION OFTHEFOLLOWNG n
ANDEQUIPMENTOBSTRUCTNGTHEWORKSHALLBE REMOVE
z
0
z
APP.P.- VEDAS NOTED LL
0 o
g
LL
=ff
DATE: 17 J� B.P. E
Z
0
ve
FEE.
-� wireless
NOT+11- BUILDING DEPARTMENT AT j,
765-1802 8 AM TO 4 PM FOR THE
U z:
FOLLOWING INSPECTION& U) >
1. FOUNDATION - TWO REQUIRED WEST NYACK, NEW YORK to E
0
Lu
FOR POURED CONCRETE -j
2;z
2. ROUGH - FRAMING & PLUMBING W
Jaz
p
zm
.
3. INSULATION WIRELESS COMMUNICATIONS FACILITY 0 m Do �
4. FINAL - CONSTRUCTION MUST Lu I u - :;:
> z m
BE COMPLETE FOR C.O. rs
ALL CONSTRUCTION SHALL MEET THE 110RIE&NT" I L<L:!Jo.0
REQUIREMENTS OF THE CODES OF NEW 0
YORK STATE. NOT RESPONSIBLE FOR
DESIGN OR CONSTRUCTION -ERRORS. 23300 MAIN ROAD
Z
ORIENT, NY- 11957 E- IP-fo
-8
V',,'ITH ALL CODES OF
CEA
NEW Y(--1)F-,1K S-15'A"FE & TOWN CODES
DRAWING INDEX SITE INFORMATION
AS REQUIREb �4 M
VZW SITE NAME 'ORIENT' cf)
SOU THO T-1 COVER SHEET&INDEX VZW SITE NUMBER NY-0000 cf)
PROJECT LOCATION 23300 MAIN ROAD,ORIENT,NY 11957 N m
S ARD SP-1 SITE PLAN&NOTES SITE TYPE/DESCRIPTION. REPLACE(6)EXISTING ANTENNAS W/(3)NEW ANTENNAS <
&RELOCATE TO TOP CONCEALMENT CYLINDER, 0>-
SOP.ItIff-ITHN'TRUSTEES A-1 PLANS,ELEVATIONS AND DETAILS ADD(2)NEW RACK MOUNTED CABINETS WITHIN r fr Z
(
fr
EXISTING EQUIPMENT SHELTER Z
(.5
A-2 ANTENNA AND EQUIPMENT DETAILS
WLu<
IROPERTY OWNER AMERICAN TOWER CORPORATION z
C)
Z 1--
W;
Lu(n
LEASING CONTACT ANTHONY LONGINETTI C)W
(908)256-3405 v.
CONSTr.UCTION CONTACT PETE McCARTHY
(631)649-2700 z
<
OT
OCCUPANCY 0 R EN'GINEER CONTACT. SCOTT CHASSE z u
�40 ,C'a:
!1� 4, f (860)663-1697 W3 .3<�
�o M�z
8-
USE IS UNLAWFUL p-,.g!Z5
LATITUDE.DE. 41'08'33 50 0 �.:
flestoratm, �o
LONGITUDE 72*1758 00'W
ELEVATION 16'.t AMSL
WITHOUT CERTIFICATE DISTRICT 1000
DIS
SECTION' 18
--
OF OCCUPANC IV
a BLOCK 5
2'3�316.Mai .'9d9 d, LOTS 13.8
epeLu
cndy&M ZONING. R-80 LU x
-�,:s�. =--.._ _-�.�.�.�. _ � < �` ` };�. SITE Lu
W z
LLJ —
>
ELECTRICAL
r'-o,,, yltwi
imspECTION, REWRED mo
N.
I�k <
\\D
0,
0
T .
VICINITY MAP
SCALE 1-500'
SS1
a -
ZONING TABLE-SOUTHOLD
y
ITEM ALLOWED EXISTING PROPOSED Z m i
MAX HEIGHT(FT) 35 •90'± NO z w
MIN LOT AREA(SF) 80,000 189,572± NO = O
z
MIN LOT WIDTH(F() .. 175' 226'± NC o , d
MIN.LOT DEPTH(F<) 250' 458 35'± NC Z K LL
MINIMUM FRONT YARD SETBA.K(FT) 60. 8308± NC O
MINIMUM SIDE YARD SETBACK-ONE(FI) 20' 75 42'± NC
MINIMUM SIDE YARD SETBACK-BOTH(FT).. 45' 156± NO
K
MINIMUM REAR YARD SETBACK(FI) ... 75' 217 58'± NO ti
MAX LOT COVERAGE 1%) 20% 5 5% NC - ------ --- - -- -- ------- ______-..,.. _ z
0 0 r o e
V > > > > >
NA-NOT APPLICABLE NO-NO CHANGE
MAIN ROAD (S.R. 25)
•EXISTING DIMENSIONAL NON-CONFORMITY
SITE PLAN REFERENCE �• Y
a o
N 80°31'30°_E
1 PLOT PLAN&POLE ELEVATION TITLED ORIENT FIRE DISTRICT,23300 MAIN ROAD,ORIENT, 3 226.00' o zzV o
N Y 11957 PREPARED FOR BEACON WIRELESS MANAGEMENT,P O BOX 303,HAMPTON r OI_
BAYS,NY 11946 REV 4,DATED 0223/06 MOVE COMPOUND BEHIND F H PREPARED BY y O n i y vi > oLL
MICHAEL WALKER DESIGN/BUILDER LLC,500 HORSENECK ROAD,DARMOUTH,MA 02784 O i I U)_ �+
1 -i rW F
2 SITE MEASUREMENTS TAKEN BY APT ENGINEERING ON Ot/1Ill 2,01/16/12&09/10/14 W o 0
z_P y� o
N m ui w
O � O Y
—r., I ---------- c)b w z
'0 0
m w
r 1 I PAVED I ,NIc67D O = Y
' AREA 0)r a Q U
EXISTING i OI a 0 _
FIRE I Q o U
O ` 1 ( STATION
PAVED 1
1 PAVED ( AREA o x
O 1 AREAL _ W w z
m trl
N 87°47'3E0° PLI
z o
EXISTING r24 5ji w 2A=
HIGH - Y�z
UNIPOLE — --
1 ( � 3`g
EXISTING
BUQ <
1 BUILDLDING 3
0 PAVED
r 1
AREA -""� A-1 1
CD
1 1 co— _ — — —
I <O
1
Q
EXISTING 1 2 z
1 BUILDING Y 1'
C)
vinc:
IWZ
J-w1N A� ZI-
o_ 010 A, Uw
OII`7 SUBJECT SITE 0 01
2 ORIENT FIRE DISTRICT 1 - f o O rn
SECTION 18, F o
1 W O= Z
BLOCK 05.
1 LOT 13 8 F W MID Iz
1 1 POt,
M 0
1 a
_ - 1
_ - S857070'0 E - - - - - - � Q o0
ri a o
SITE PLAN c <
SCALE:1"=40'.0" (/)
o
GRAPHIC SCALE
o s g
11nch40 FEET)R or
\\\\\1��\\\al uullF11=@t(r ur/r
` O
m
m �
MAIN ROAD(S.R.25) z w a
(BEYOND)
TOP 0
AMPHENOL Z
CWWX063X25GOO =
EXIST EXIST41 0[be a LL OLL
0:
FIRE FIRE 12 0• 8 23 SF D e
HOUSE HOUSE TJ IXIST UNIPOLE REPLACE(6)EXIST VERIZON
@ 9a-0's AGL
WIRELESS UNIPOLE MOUNTED F'
SECTOR ANTENNAS(90°,210°, Z e
EXIST LATTICE JET/NEW VERIZON WIRELESS ANTENNAS 0 e n
1 4&5 330')W/(3)NEW ANTENNAS(90°, 0 n o
TOWER'�' @ B9'-fi's AGL q_z q_t 210',330')ADD(6)DIPLE(ERS w w w w w
a FREPLACE EXIST COAX CABLES z w m rc z
- \ x CU NEWVERIZON WIRELESS ANTENNAS CONCEALMENT RELCCATETOTCP
330° REPLACE(6)EXIST VERIZON @ 85'-4'±AGL I <
�\� y 1 WIRELESS UNIPOLE MOUNTED 7 Y
SECTOR ANTENNAS 190°,210°, d
EXIST VERIZON WIRELESS \ "' 4&5 330')W/(3)NEW ANTENNAS
CABLE TRAY W/(12) \ (90'.21 Cr,330')ADD(6) CV EXIST AT87 CONCEALMENT �I STRUCTURAL NOTE Q
REPLACEMENT COAX CABLES ,� \ wl
DIPLEXERS REPLACE EXIST @ 75'-0'±AGL PLEASE REFER TO STRUCTURAL U) N a e
x COAX CABLES RELOCATE TO l i to 0
EXIST i ANALYSIS COMPLETED BY OTHERS W 3
CONC A-z TOP CONCEALMENT CYLINDER �I AVAILABLE UNDER SEPARATE COVER W H g Q Q
PAD r d.Z :E 0 0
CV EXIST VERIZON WIRELESS ill W
O EXIST CHAIN ,_i _ '\xx x CONCEALMENT CAVITY i I z P o
LINK FENCE \c, J�TO BE ABANDONED �I� Z ymj o 6
0]m ; x @ 65'-0'!AGL t (6)EXISTING O m ui m w
v \`'I EXIST l i= VERIZON WIRELESS m K . 00 y
x ,B METER ANTENNAS NEW TO �' O1 W = 0 m
a BANK - LIQ BE REMOVED i = m 0
EXIST VERIZON WIRELESS iii �i
11'-6'x30'(345±SF)EQUIPMENT �=210° a � g F v + w
SHELTER W/DIESEL
GENERATOR&(3)GPS UNITS
ADO(2)NEW RACK MOUNTED t \ / \ ' \ ' /' t x EXISTING WHIP ANTENNA
CABINETS WITHIN -- --- --- -- --- -- -- - EXIST 9a± BV OTHERS,TYP ^
HIGH UNIPOLE `$q
x x x �^
1 IGPS-TMG-HR-2NCR p
EXIST AT&T PAD z
MOUNTED }' -'"' I 2' 0 x
i s
x ...._. EQUIPMENT
a=90° HW
CO XC REPLACEMENT Z s
EXIST LATTICE TOWER COAX CABLES ROUTED 12(r 7 1° W
WITHIN POLE TO RELOCATED I� _F
ANTENNA CAVITYCOMPOUND PLAN ( 0
FROM BIDE a0.0
EXIST FIREHOUSE ; PANEL ANTENNA GPS UNITS oz3
MAIN ROAD(S R 25) i I EXIST 90'±HIGH UNIPOLE n 3
(INFEET)lI.h-8 e fL4 ANTENNA DETAILS n
QSCALE•3/a"=1''0- 01
cl
' 1 I MST VERIZON WIRELESS L Q>-
1 l-6'x3U(345±SF) � [[Z
Q f -� Tt _ - i I 3 EQUIPMENT SHELTER WJ
DIESEL GENERATOR&(3)GPS 4-Lines 1 Antenna Y Y
U
1
UNITS.ADD(2)NEW RACK 00
p I MOUNII tU CABINETS Wl I HIN ¢}
° L......__,
EXIST G �________________.r.J _ �Z
-}' 1 FENCED
I q_t WIRELESS i_ I 700!850-PCSIAWS W�
COMPOUND i X � U W
�� 1 .�__ I I l/• _ Z
r - — ao F a.
( 1 GRADE o\./
__________- (16'±AMSL) (t' ' W D m=ZSOUTH ELEVATION 0 0
� — - -- - - -------- � t w W,§F
V K NO
/1\\; Yi a
A
301=
SECTOR ALPHA BETA GAMMA DELTA EPSILON ZETA EXIST VERIZON EXIST VERIZON WIRELESS 11'-6•x3a �t Z
BASE COLOR WHITE BLUE GREEN WHIT STRIPE WHI TEIRED STRIPE WHITE/GRN STRIPE I WIRELESS CABLE (345=SF)EQUIPMENT SHELTER I PA PA
850 GRAY GRAY GRAY GRAY GRAY GRAY + ENTRY PANEL O U) o c
LTE-C RED RED RED REO RED RED LOCATION MAP (16 PORT,1 OPEN)
LTE-A ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE =I SCALE:'1'�75'-0' W/(12)REPLACEMENIT '
PCS PURPLE PURPLE PURPLE PURPLE PURPLE PURPLE ••11 �/e COAX CABLES ROUTED Q Q
GPSS YELLOW BROWN YELLOW YELLOW YELLOW YELLOW YELLOW TO BASE OF UNIPOLE DOOR DOOR -'- - -'- - -'- - -'- "-'- -'- W W o
O
FILE 1Fj4
W Q i
ANTENNA DATA NOTE �> r a
VE
CONTRACTOR TO FIELD VERIFY ALL CABLE LENGTHS PRIOR TO ORDERING NEW CABLE(TYP EACH SECTOR) 2 (1)NEW VERIZON1)NEW - Z
WIRELESS AWSERIZQN < J, Z Q
EXISTING ANTENNA SPECIFICATIONS ANTENNAS,AZIMUTH AND MECHANICAL DOWN TILT FIELD VERIFIED NEW ANTENNA SPECIFICATIONS RACK MOUNTEDIRE4ESS i w H a
CABINET BELOWCS RACK w 1- PA
E- M- ANITENNA CABLE CABLE E- M- ANITENNA CABLE CABLE -SECTOR MODEL QN AZIMUTH SECTOR MODEL QTY AZIMUTH EXIST LTEOUNTEDD-TILT D-TILT STATUS SIZE LENGTH D-TILT D-TILT STATUS SIZE LENGTH wCABINETCAB(N_ET4 ZALPHA CELL X7C-480(UPPER) 1 0° 0° REPLACE (4)T/g' g2'± 90° Q - /, figOK V 1 m OPCSILTE-C X7CAP-480-I(LOWER) 1 0° 0° REPLACE ALPHA CELLtLTE-C/AWSIPCS-LTE CWWX063X25G00 1 0° 0° NEW (a)7/a 112" g0° DESK7Y�_ F' I ---1
i__
BETA CELL X7C-480(UPPER) 1 0° 0° REPLACE eW �T6.7c \\N\\\��!
PCS/LTE-C X7CAP-480-i(LOWER) 1 0° 0° REPLACE (4)7/B 97 210° BETA CELLA -C/AWS/PCS-LTE CVJVJX063X25G00 1 0° 0" NEW (4)7/ti 112'± 210' EXIST VERT?ON WIRELESS �i S ` � 1 \��`( V /
GPS UNITS(TYP OF 3) EXHAUST FAN ALPHA BETA GAM�FS/
GAMMA CELL X7C-460(UPPER) 1 0° V REPLACE (4)7/e 82,,, 330, ANTENNAS CbAX
PCS/LTE-C X7CAP-480-1(LOWER) 1 0° 0° REPLACE GAMMA CELLILTE-C/AWSIPCS-LTE CWWX063X25000 1 0° 0° NEW (4)%yj 112's 330° •\EQUIPMENT SHELTER5 CABLE DIAGRAM
GPS PCTEL GPS-TMG-HR-2N 3 - - - 2)%'&(1)3� 16'± N/A GPS - - - - - - - N/A
• %� AA 785 �v ����
N �
Z N 6
� � N
� m
0 Z
- LL
p O
0
U p
z
H
N
0
O U
y=330°
EXISTING UNIPOLE •I z s
INTERNALANTENNA
4 (3)NEW VERIZON MOUNTING PIPE o
Al WIRELESS ANTENNAS I I Ya
(6)NEW DIPLEXERS(BELOW)
�d
U
EXIST COAX y N p
CABLESTO -� Lu
REMAIN 3 NOT USED r4AOT USED
�(3)NEW VERIZON WIRELESSLLI
,~
ao RF TRANSPARENT II I PANEL ANTENNAS -2 -2 K
> RADOME- II L II
Z o
_P W
O m w N y
EXIST' I I N z p y
(� HIGH UNIPOLNIPOLE I I I LLI� O r
m
Q=210°
7 0 z w
(6)NEW DIPLEXERS
2 EXISTING ANTENNA
n 2 HOUSING ASSEMBLY
EXIST WHIP *m
ANTENNAS BY
OTHERS
131
Hz
ANTENNA MOUNTING PLAN ANTENNA MOUNTING DETAIL r5- NOT USED s NOT USED NOT USED ¢z E9s
'2 W p u o
u-
m3a
w
UC
°oz3
H=3
!n
a
01
O
>- ¢Z
Y Y
UU
OQ
wZ
a NOT USED s NOT USED 10 NOT USED 11 NOT USED 12 NOT USED �C W
'2 ; °3
000�
oma
w°'gz
0Z
UOW
C NO
a
17 84'
I� U)
zI-- F e
PLAN Q
17 64' 16 83° z 0
z z
Lu Lu
o - z a
w
G
CY
O V
FRONT SIDE Lu 5
ALCATEL LUCENT 9412
e No
C OT RACK
UNT
OMO
WxD dH BIND 991Rfi 991 IN 6- 400 Lbs) SIDE/RACK ��°�����' N m
C.
INDOOR RACK
s
13 NOT USED 14 NOT USED 15 NOT USED rldNOT USED 17 eNodeB CABINET =0
-2 SCALE:Y;01'-0' =2 K J
4
�j
s C'Io \\\\
/!4/llpgllll I Iltl III1114U11\\\