HomeMy WebLinkAbout42753-Z �S�FfOt,��p Town of Southold 9/24/2021
'? P.O.Box 1179
o = 53095 Main Rd
Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 39822 Date: 8/3/2018
THIS CERTIFIES that the building SOLAR PANEL
Location of Property: 825 Stephensons Rd, Orient
SCTM#: 473889 Sec/Block/Lot: 17.4-11.5
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
5/29/2018 pursuant to which Building Permit No. 42753 dated 6/4/2018
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which thiscertificate is issued is:
ROOF-MOUNTED SOLAR PANELS TO AN EXISTING TWO FAMILY DWELLING AS APPLIED FOR.
9/24/2021 Corrected to soy two family instead of single family.,
The certificate is issued to Gentlemans Ridge LLC
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 42753 07-27-2018
PLUMBERS CERTIFICATION DATED
A rize gnature
`oS�FFO(,YC TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
o� • o� SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 42753 Date: 6/4/2018
Permission is hereby granted to:
Gentlemans Ridge LLC
404 W 45th St
New York, NY 10031
To: install roof-mounted solar panels on existing single-family dwelling as applied for.
At premises located at:
825 Stephensons Rd, Orient
SCTM # 473889
Sec/Block/Lot# 17.-1-11.5
Pursuant to application dated 5/29/2018 and approved by the Building Inspector.
To expire on 12/4/2019.
Fees:
SOLAR PANELS $50.00
ELECTRIC $100.00
CO -ALTERATION TO DWELLING $50.00
Total: $200.00
a I--,'
B ' din nspector
Form No.6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or
topographic features.
2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead.
5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate
of Code Compliance'from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings(prior to April 9,1957) non-conforming uses,or buildings and "pre-existing"land uses:
1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied,the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificaie of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00,
Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00.
2. Certificate of Occupancy on Pre-existing Building- $100.00
3. Copy of Certificate of.Occupancy-$.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy -Residential $15.00,Commercial $15.00 'T/
Date. ,6—, 2` - / 9
New Construction: Old or Pre-existing Building: v/ (check one)
S?-c- A
Location of Property: 02 cnzcns Rd Or u/it
House No. Street . Hamlet
Owner or Owners of Property: �E'✓1�'��YYldrl 5 -k d/V L(—"--
Suffolk County Tax Map No )000, Section Block Lot - S
Subdivision Filed Map. Lot:
Permit No. Date of Permit. Applicant: GreenLogic LLC
Health Dept.Approval: Underwriters Approval:
Planning Board Approval:
Request for: Temporary Certificate Final Certificate: V1 (check one)
Fee Submitted: $ 50.00
pplicant Signature
� o
Town Hall Annex Telephone(631)765-1802
54375 Main Road N Fax(631)765-9502
P.O.Box 1179 �Q roger.rich erKD-town.southoId.ny.us
Southold,NY 11971-0959
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICIAL COMPLIANCE
SITE LOCATION
Issued To: Gentlemans Ridge LLC
Address: 825 Stephensons Road city,Orient st: New York zip: 11957
Building Permit#: 42753 Section: 17 Block 1 Lot: 11.5
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
contractor: DBA: Green Logic License No: 43858-ME
SITE DETAILS
Office Use Only
Residential X Indoor X Basement X Service Only
Commerical Outdoor X 1st Floor Pool
New Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
INVENTORY
Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures
Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors
Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps
Transformer Appliances Dryer Recpt Emergency FixtureTime Clocks
Disconnect Switches Twist Lock Exit Fixtures TVSS
Other Equipment: 10.500 KW Roof Mounted Photovoltaic System to Include, 30-SP 350 Panels with
Micro- Inverters, Combiner Box, AC Disconnect.
Notes:
Inspector Signature: Date: July 27, 2018
0-Cert Electrical Compliance Form As
pF SOUIyO{o
# TOWN OF SOUTHOLD BUILDING DEPT.
courm 1 765-1802
- INSPECTION
[ ] FOUNDATION 1 ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) V�] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] CAULKING
REMARKS:
DATE 11 INSPECTOR
J AMES J. S TOUT A R C H I T E C T & Assoc.
2 GREG -LANE EAST NORTHPORT N. Y. e s 1 — 8 58 9388
Post Installation Letter
July 20,2018' '�
RE: Gentlemans Ridge LLC Residence u JUL 2 5 `,'918
825 Stephensons Road
Orient, NY 11957
BUELDDTG
To Whom It May Concern:
This letter is to confirm that as of this date July 20,2018,I,James J Stout,NYS license 021633
have personally inspected the placement and installation of the roof top solar panels at the
above listed address. All of the solar panels have been installed as per manufacturer's
guidelines and specifications. The racking system design and installation complies with the
2017 NYSRC and 2017 NYSUCS building code and all related provisions.The installation of
panels was done as per plan.
Thank you for your cooperation in this matter.
James J.Stout
Architect
R AR
ST
9 021633 COQ
0F NE`s
FIELD INSPECTION REPORT DATE COMMENTS
FOUNDATION(IST)
--------------------------------
'FOUNDATION (2ND)
04,
O
N
ROUGH FRAMING&
PLUMBING tz �
1
INSULATION PER N.Y: y
STATE ENERGY CODE
FINAL
ADDITIONAL COMMENTS
C.
e-4e
0
JN
m
y
�z
d
b
H
� 1
TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following,before applying?
TOWN HALL Board of Health
SOUTHOLD,NY 11971 4 sets of Building Plans
TEL: (631)765-1802 Planning Board approval
FAX: 631 Surve
FAX: (631) 765-9502 y
SoutholdTown.NorthFork.net PERMIT NO. 2� Check
Septic Form
N.Y.S.D.E.C.
Trustees
Flood Permit
Examined ,20 f Storm-Water Assessment Form
Contact:
Approved ,20 Mail to: GreenLogic LLC
Disapproved a/c 97 North Sea Road,Southampton,NY 11968
Phone: 631-771-5152
Expiration 2011
D D Buil ' ector p
MAY 2 9 2010 APPLICATION FOR BUILDING PERMIT
BUILLDINGDI", Date May 24 , 20 18
TOWN OF SOUTHOLDINSTRUCTIONS
a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans,accurate plot plan to scale.Fee according to schedule.
b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas, and waterways.
c.The work covered by this application may not be commenced before issuance of Building Permit.
d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the
property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an
addition six months.Thereafter,a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or
Regulations,for the construction of buildings, additions,or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code,housing code,and regulations,and to admit
authorized inspectors on premises and in building for necessary inspections.
GreenLogic LLC
(Signature of applicant or name,if a corporation)
97 North Sea Rd, Suite 3, Southampton, NY 11968
(Mailing address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder
Contractor
Name of owner ofpremises � '��Vv1a� LLC—
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Nam and title of co orate officer)
Builders License No. 40227-H
Plumbers License No. N/A
Electricians License No. 43858-ME
Other Trade's License No. N/A
1. Location of land on which proposed work will be done:
8 as S40DhCO-5UrLS A!� �►- l en
House Number Street Hamlet
County Tax Map No. 1000 Section Block Lot //. ,S-
Subdivision
/. SSubdivision Filed Map No. Lot
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy Single family dwelling
b. Intended use and occupancy Single family dwelling
3. Nature of work(check which applicable): New Building Addition Alteration
Repair Removal Demolition Other Work Roof mounted solar electric system
2-00
0 (Description)
4. Estimated Cost Fee
(To be paid on filing this application)
5. If dwelling,number of dwelling units Number of dwelling units on each floor
If garage, number of cars
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. Dimensions of existing structures, if any: Front Rear Depth
Height Number of Stories
Dimensions of same structure with alterations or additions: Front Rear
Depth Height Number of Stories
8. Dimensions of entire new construction: Front Rear Depth
Height Number of Stories
9. Size of lot: Front Rear Depth
10. Date of Purchase Name of Former Owner
11. Zone or use district in which premises are situated
12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO_X
13. Will lot be re-graded?YES NO X Will excess fill be removed from premises?YES NO
5 `{04 W. lqS 5t14.Names of Owner of premises9��Ltllv"n� Address Ny , NV 106 3 I Phone No.
Name of Architect.Jaryy5 5 pt,&t- Address t3W% .+ Phone No 3/• 3,98- 4388
Name of Contractor GreenLogic LLC Address 97 North Sea Road Phone No. 631-77'1-5152
Southampton, NY 11968
15,a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO
* IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey,to scale,with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES NO
* IF YES,PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUNTY OF Suffolk )
Nesim Albukrek being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)He is the Contractor
(Contractor,Agent, Corporate Officer,etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be
performed in the manner set forth in the application filed therewith.
Sworn to before me this
2�day of Ma 20 ( FS
6L
Notfiry Public BARBARA A.CASCIOTTA Signature of Applicant
Notary Public,State of New York
No.01-CA4894969
Qualified in Suffolk COU*
Commission Expires May 11,2019
Scott A. Russell S'7C'O]RLMWAT EIK
SUPERVISOR
MAN AtG17EMIEN T
SOUT 4OLD TOWN HALL-P.O.Box 1179 Gi
53095 Main Road-SOUTHOLD,NEW YORK 11971 °��p Town (?f Southold
CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET
( TO BL C:OMPLL,'TED BY 'i'I IL. APPLICANT )
FROJI'M 11`4`VO1:VI•:.. ,"N"Y O 'ME F0'11L0'\N`-'CL`G:
THEC-K ALL I'l-MT APPLY"
if Yc� No
❑[D A. Clearing, grubbing, grading or stripping of land which affects more 1"
than 5,000 square feet of ground surface. l
x® B. Excavation or filling involving more than 200 cubic yards of material ;3
within any parcel or any contiguous area.
rl ] C. Site preparation on slopes which exceed l0 feet vertical rise to
100 feet of horizontal distance.
®E] D. Site preparation within 100 feet of wetlands, beach, bluff or coastal
erosion 'hazard area.
;j ❑� E. Site preparation within the one-hundred-year floodplain as depicted i
on FIRM Map of any watercourse.
❑0 F. installation of new or resurfaced impervious surfaces of 1,000 square 1
feet or more, unless prior approval of a Stormwater Management li
l' Control Plan was received by the Town and the proposal includes 'f
in-kind replacement of impervious surfaces.
If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name,
Signature, Contact Information,Date & County Tax Map Number! Chapter 236 does not apply to your project.
If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan
and a completed Check List Form to the Building Department with your Building Permit Application.
1 F- -s; s.C.T.N1. 1000 Date /
s+ API'LlCA\-r. (Piopert;Owner Dexsgn Notcamonal Ay.ni C�ontiactoi,C)11mi + Uistict / r/�
1 l IIs J (( a
'vrliiL i
Section Bloc l; Luz
_ .
— FOR H) ILDIN"(a DEl:1Al11-?'ll:_tiN 1F LJSL: ()N[,`i
Contact intorman,m 691'-771-5152
Reviewed Bv.
+ - - - - - - _. - - - - - _. ._ .._.. _. _ Cate: ��!�L�-._._ +f
}{ Prohertti, Address( Local ion of Construel t n Work: 1'
�a 5 S /_ �e�155 / =Yt)pl oti eel for processing Building Permit.
{� ��d rtater �ana�elleut Control Plan et Required.
ml :.
— — — — — — — — — — ,
a Storni,,%alcr Mana enient Control Plan is Required.
E. 1Fatx+°aicl to Engineering Uepaittueiit fa Rcview.?
i ol*11i ° sl�icp--r«S:ti°1:1Y 2U 14
�, FOtKr BUILDING DEPARTMENT-Electrical Inspector
TOWN OF SOUTHOLD
Town Hall Annex - 54375 Main Road - PO Box 1179
Southold, New York 11971-0959
4-4
Telephone (631) 765-1802 - FAX (631) 765-9502
roper.richert@town.southold.ny.us
APPLICATION FOR ELECTRICAL INSPECTION
REQUESTED BY: Barbara Casciotta Date: 5/24/18
Company Name: GreenLo is LLC
Name: Robert Skypala
License No.: 43858-ME email: Barbara@Greenlogic.com
Address: 97 North Sea Road Southampton, NY 11968
Phone No.: 631-771-5152
JOB SITE INFORMATION: (All Information Required)
Name: Gentlemans Ridge LLC
Address: 825 Stephensons Road, Orient
Cross Street: Route 25
Phone No.: 631-7,715- 152
BIdg.Permit#: email: Barbara@Greenlogic.com
Tax Map District: 1000 Section:. 17 Block: 1 Lot: 11.5
BRIEF DESCRIPTION OF WORK(Please Print Clearly),
Roof mounted solar panels 10.500kW
30 SunPower SPR-X21-350-BLK-D-AC modules with micro inverters
Circle All That Apply:
Is job ready for inspection?: YES /g Rough In Final
Do you need a Temp Certificate?: cyES:yNO Issued On
Temp Information: (All information required)
Service Size 1 Ph 3 Ph Size: A #Meters Old Meter#
New Service- Fire Reconnect- Flood Reconnect-Service Reconnected - Underground - Overhead
# Underground Laterals 1 2 H Frame Pole Work done on Service? Y N
Additional Information:
PAYMENT DUE WITH APPLICATION
r
l/V—
82-Request for Inspection Formas C
4 16D �)
REENLOGIC°
ENERGY
May 24, 2018
Town of Southold IVY
Building Department D �� D
Town Hall
53095 Route 25 SAY 2 9 2018
Southold, NY 11971
Dear Building Inspector: -BUMDjTODFM-
.r0WN OV SOUTHOLD
Please find attached a building permit application on behalf of the Gentlemans Ridge LLC
residence who has engaged us to install a roof mounted solar photovoltaic (PV) electric system
for their home located at 825 Stephensons Road, Orient, NY.
In connection with this application, please find attached:
• Building Permit application
• A Storm Water Assessment Run-off Form
• Certificate of Occupancy Application
• Application for Electrical Inspection
• 2 Surveys of the Premises
• 4 Engineer's Reports (3 originals and 1 copy)
• 2 Three Line Electrical Drawings
• 2 Spec. sheets of the solar panels
• 2 Spec. sheets for Racking System
• GreenLogic Suffolk County Home Improvement License
• GreenLogic Certificate of Liability Insurance
• GreenLogic Certificate of Worker's Compensation Insurance Coverage
• Installation Manager's Master Electrician's License
• Check for$200 ($50 Building Permit/$50 CO/$100 Electrical Inspection)
Please let us know if you need anything else in connection with this application.
Yours truly,
944&V"daaeloaa
Barbara Casciotta
Account Manager
Barbara@Greenlogic.com
631-771-5152 ext. 117
GREENLOGIC LLC o www.GreenLogic.com Tel 631 771 5152 Fax. 631.771.5156
SOUTHAMPTON ROSLYN HEIGHTS
97 North Sea Rd., Suite 3 200 S. Service Rd., #106
Southampton, NY 11968 Rosyln Heights, NY 11577
GREENLOGICO
ENERGY
Jul 242018 D
July JUL 2 5 2018,
13UMDMG DF r, ',
TOWN OFSo jj'
The Town of Southold
Building Department
54375 Route 25
P.O. Box 1179
Southold, NY 11971
Re: Building Permit No. 42753
Gentlemans Ridge LLC
825 Stephensons Rd, Southold
To the Building Inspector:
Enclosed please find the Engineer's Certification Letter for the above referenced
address. Can you please close the building permit and send the Certificate of
Occupancy? Please let me know if you have any questions about the installation.
Sincerely,
Sawaaff"6612"
Samantha Corbett
Account Manager
Samantha.Corbett@Greenlogic.com
631-771-5152 Ext. 107
GREENLOGIC LLC • www.GreenLogic.com Tel. 631.771.5152 Fax 631 771 5156
SOUTHAMPTON ROSLYN HEIGHTS
97 North Sea Rd., Suite 3 200 S Service Rd , #106
Southampton, NY 11968 Rosyln Heights, NY 11577
`.\ to 09 T1i c 9i'�'IOIH
-1 mm��rp�u�e,nwe-ngcen
\ now or Pormarly� Oulu�'{�Oliit�
`•\
9u9an Magri—Dunning •`\
Nwwe,t Ywg Icw svrys
`.\ •`\ 1 N o'�wqe:a 4m�e`�'na:°°ui'�w ss'9y�
JP,
O SITE DATA
//� �„ �$��:,•;'' �� now or Formerly \• �; •`� W
v' L.M.L Edon \/ j• •\ •rvors rgnm=cc Yo suevlws�oH-•9um er ++e c®.rs9•
•�o��P�9a IS IN P�m,zore x.s sNo.w aN ww,
�/�\ �.```���+., '..•` ♦ i ��'� �� ��Ror� •� AREAS
�/ •� �� "�B9 bili ��� rm 4p��� \ rm.0�'aew 9°eo i.e�
m o� rwv[um 4,e � .9sssl
V4;. I srtoP nn a v d C ROT% .
R PARGH..I N n d Ja
?�8' ',+° ,` 1 '� r•e �� now or formerly
•rd' Joanna W Loma.t
ry Charlotte Jordan r
4`°,
reenee`° •` \ rLOT W 1et vn.wvrr ,b°nN$
4{ `x000.fewan N2 ,i�� t a i4
PLOT w a• 8$a i
q,•�, s9. or.Ma a - w24sm
`P• �• o w�
95 ICIIp
�' �'✓`+� � �4� cv
mww•.e rm �g � 5 or me now or Formerly
�•p,Ay, 59a•o9'S5'w� Reginald A Minor Jr I ,
2191' d Sheila K Minor
R 450 9nwufo vwownv `\ v PARCEL 2 i
wor formerly 9 L.2aL5' PRIVATE ROADS
Ran A,Malemud i rovsru PLoi R I
ouwzr,� amm i
or formerly \y�
bm•"� Mark Stephenson Sherman
b
now or formerly /\\\ vc.w me avers
N,9o.00 Beverley L Greene d
Le5o.ab' Charlotte Jordan Greene _ SURVEYOR5 CERTIFICATION
a a'renAIT, ewi`rTa Roupineuwwwowb
PniPor o'nec IA IenoanOUP,
S si.°.�iv vr.s
eNer°'nrseo w i.ccovvnuce wfn M cove�nwwn�,�ee�
�� ,%, �/, i uw axwer.Avon®sr nx nEn You srnm
a=a«aresslvNnL I...w su¢vcroas
now ormerly
Sharman n F
Family Tru.
Na0,99x9
SURVEY FOR
P
� PLOT M � ••�f FRANCISCO PIh1EDA
y I at Orient,Town of Southold
% 77 va
norySuffolk County,Naw York
j mr formerly Tmi
Ada J 1-Ing t ,g o f I CERTIFIED SURVEY
' Lydia N Irving m 0 3
TaMap
0
ealml�
e! � �2� i Recofd o!Ravl9bn9
__
NMN RO?�D S.iZ. 25 sae, •.- '
— �oP
...........
MAkX,
'T§VW RXI
S j t�
V -44, *11* r.
k 'iSuffolk County Executive's Office of Consumer Affairs
&1V
VETERANS MEMORIAL HIGHWAY HAUPPAUGE,NEWYORK 11788
DATE ISSUED: 5/25/2006 No. 40227-H
SUFFOLK COUNTY
Home Improvement Contractor License
-N,
This is to certifv that MARC A CLEAN
doing business as
GREEN LOGIC LLC
having fumished the requirements set forth in accordance with and subject to ths-jY
e provisions of applicable laws,rules
and regulations of the County of Suffolk, State of New York is hereby licensed to conduct business as a HOME
IMPROVEMENT CONTRACTOR,in the County of Suffolk.
Additional Businesses
NOT VALID WITHOUT
DYPARTMENTAL SEAL
AND A CURRENT
CONSUrv,IER AFFAIRS ...... .. ....::,
ID CARD ..........
Director
K
"A
Im
&
IN
A. 1. Lr, 14 \f-HIGHWAY HAUPPAUGE, NEWYORK 11788
VETERANS MEMORIAL I
\ �\ \
Suffolk County Executive's Office of Consumer Affairs
. I D• 12/10/2007 No.
ISUFFOLK COUNTY
Master Electrician License
1 �' This is to certify that ROBERT
doing business
GREENLOGICLLC
having _ •ry evidence of • . herebylicensed as MASTER ELECTRICIAN in accordancerte,
with • subject to the provisions of .. . and regulations •Additional Businesses
Jr.
the County of Suffolk State of New York./
��,�\ �:. •�• NOT VALIOD WITHOUT
DEPARTMENTAL
ANDA'
I
/ CONSUMER R ` 1
Director
I
t ` Y �
'. f`
rr '
• y ,:.:f`� . . . •f '_,; .ter` al•�-•: �s•'`;+�<,. '�•�\� ,�.�;. S4 ,:�;, ?�: c,- : -.� _,r1 _• _
7
\' ��:��;� /ice,, ?�l , � f! \\��`I�� f/,'�\ �a� •�"�� /�.\ �41���� I/`�!� •" � a��. !i \',•. ���:��`° // \\ '. `� • :��/ \\ t �F
APPROVED, AS NOTED
DATE: B.P.`# a2 75 3 .�
:FEE: bBY: RETAIN STORM WATER RUNOFF
PURSUANT TO CHAPTER 236
NOTIFY BUILDING DEPA TMENT AT - OF THE TOWN CODE.
.765-1802 SAM TO 4 PM FOR THE
"FOLLOWING INSPECTIONS:
-1._,FOUNDATION - TWO REQUIRED
FOR POURED CONCRETE
2.''ROUGH - FRAMING & PLUMBING
3. .INSULATION ELECTRICAL
4. FINAL - CONSTRUCTION MUST INSPECTION REQUIRED
COMPLETE FOR C.O.
ALL CONSTRUCTION SHALL MEET THE
REQUIREMENTS OF THE CODES OF NEW
YORK STATE. NOT RESPONSIBLE FOR
DESIGN OR CONSTRUCTION ERRORS.
COMPLY WITH ALL CODES OF
NEW YORK STATE & TOWN CODES
AS REQUIRED AND CONDITIONS OF
''S6lfFHeEB T6MRSA,
t RD
' BREES
Iry
V VL
OCCUPANCY OR
USE IS UNLAWFUL
WITHOUT CERTIFICATE
OF OCCUPANCY
11L L 1111 1
J A M E S J. S TOUT A R C H I T E C T & Assoc.
2 G REG L ANE E AST N ORTHPORT N. Y. 831 - 858 9388
Letter of Certification
May 18,2018
RE: Gentleman's Ridge LLC
826 Stephenson's Road
Orient, NY 11957
To Whom It May Concern:
I, James J. Stout, registered architect NYS license number 021633 would like to
submit the following. I have inspected and analyzed the roof structure at the above-
mentioned address and have determined the structure and the panel attachment to
be adequate to support the new additional load imposed'by the proposed solar panel
system and complies with the 130-mph wind design load as 2017 New York State
Uniform Code(2017 NYSUC), 2017 New York State Residential Code (2017
NYSRC) = (2015 International Residential Code (2015 IRC) (2nd Printing) and 2017
New York State Uniform Code Supplement(2017 NYSUCS) as well the Long island
Unified Solar Permit Initiative (LIUSPI) and the 2014 National Electric Code NFPA 701
2014 National Electric Code, and the ASCE 7-10. -
The existing 2"x 8" @ 16"o.c. roof rafters will provide the required support.
Thank you for your understanding in this matter.
James J Stout
SPE® ARC
- S
41
�-yT X21633 AO
0F N�
f- r
GREENLGGNCG
ENERGY
GreenLogic,LLC Approved
Gentiemans Ridge LLC
825 Stephensons Road
Orient,NY 11957
Surface#A:
Total System Size:10.500M
Array Size:10.500kW
1 Circuit of 12 on a 20A Breaker
1 Circuit of 12 on a 20A Breaker
1 Circuit of 6 on a 20A Breaker
Azimuth: 150°
Pitch:34°
Monitoring System:
SunPower .0
Panel/Array Specifications:
Pane:SPR-X21-350-BLK-D-AC
Racking:SunPower Invisimount
Panel:61.39"X 41.18"
Array:25'9 7/8"X 20'10 7/8"
Surface:27'4"X 23'6"
Magic#:Invisimount
Legend:
® 30 SunPower 350W Panels
® SunPower Invisimount Rail
® 72 S5!-S Clamps
8�
Val Drexel Metals Standing Seam Roof—
5505 SL-3 Bead 16"OC
Notes:
Number of Roof Layers:1
Height above Roof Surface:4"
Materials Used:S5!,SunPower
Added Roof,load of PV System:3.5psf
Engineer/Architect Seal:
A0
y�o �
'9 02'1633 A0
OF N E`N
r
Drawn y:MMB Drawing#1 of 5
s,e'5/15/2017 REV:A
Drawing Scale:3116"=1.0'
s NLGGOC°
n EN ERGY
GreenLogk,LLC Approved
Oentlemans Ridge LLC
825 Stephensons Road
Orient,NY 11957
Surface#A:
Total System Size:10.500kW
Array Size:10.500kW
1 Circuit of 12 on a 20A Breaker
1 Circuit of 12 on a 20A Breaker
1 Circuit of 6 on a 20A Breaker
Azimuth:150°
I Pitch:34°
'X ' Monitoring System:
SunPower
Panel/Array Specifications:
l gi i i Panel:SPR-X21-350-BLh-D-AC
Racking:SunPower Invisimount
Panel:61.39"X 41.18"
Array-25'9 7/8"X 20'10 7/8"
Surface:27'4"X 23'6"
n Magic#:Invisimount
Legend:
30 SunPower 350W Panels
® SunPower Invisimount Rail
72 S51-S Clamps
lVal Drexel Metals Standing Seam Roof—
550S SL-3 Bead 16"OC
L ILS
Notes:
Number of Roof Layers-1
Height above Roof Surface:4"
Matenals Used:S5!,SunPower
Added Roof load of PV System.3 5psf
N.
EngineerlArchitect Seal:
l I �
A&
5 ST,
44i
I
— S,a A-
0 163
Drawn By:MMB Drawing#2 of 5
Dat A /15/2017 REV:A
Drawing Scale:3/16"=1.0'
G R E E NLOG 9 °
ENERGY
GreenLogic,LLC Approved
Gentleman Ridge LLC
825 Stephensons Road
Orient,NY 11957
Surface#A:
Total System Size:10.500kW
Array Size-10.500kW
1 Circuit of 12 on a 20A Breaker
1 Circuit of 12 on a 20A Breaker
1 Circuit of 6 on a 20A Breaker
Azimuth:150°
Pitch:34'
Monitoring System:
SunPower .0
Panel/Array Specifications:
r Panel:SPR-X21-350-BLit-D-AC
Racking:SunPower Invisimount
Panel:61.39"X 41.18"
Array:25'9 7/8"X 20'10 7/8"
Surface:27'4"X 23'6"
Magic#•Invisimount
Legend:
® 30 SunPower 35OW Panels
� N N fh
® SunPower Invisimount Rail
72 S5!-S Clamps
i8 Val Drexel Metals Standing Seam Roof-
550S SL-3 Bead 16"OC
Notes:
Number of Roof Layers:1
Height above Roof Surface:4"
Materials Used:S51,SunPower
Added Roof load of PV System:3.5psf
Engineer/Architect Seal:
-------------
�A A/?
Sr'
-9 0-2163'3 -A0
OF NE�
a
1.7tZ:
By:MMB Drawing#3 of 5
5/15/2017 REV:A
Drawing Scale:3/16"=1.0'
GREENLOGOCO
3
No vent Pipes Will Be Covered By The Solar Array ENERGY
GreenLog<ic,LLC Approved
Gentlemans Ridge LLC
LEGEND: 825 Stephensons Road
AR.Access Roof per 8202 Definitions Orient,NY 11957
GA-Ground access area per R324.7 3 width to be the same as AP as measured at eave
RAP.Roof Access Point,to be away from overhead obstructions,doors,windows,decks,fences and landscaping Total System Size:10.500kW
AP.Access Pathway W"Mirnmcrm width par R324 7 A and 8324 7 5
RWV-Roof with valley.18"minimum from valley Array Size.10.WOW
SVO-Smoke vent operation per R324.7.7.18"minimum from ridge 1 Circuit of 12 on a 20A Breaker
1 Circuit of 12 on a 20A Breaker
1 Circuit of 6 on a 20A Breaker
A7imuth:150°
Pitch:34°
Monitoring System:
RAP SunPower
Previously Panel/Array Specifications:
Installed Ground Panel:SPR-X21-350-BLK D-AC
Racking:SunPower Invisimount
Mount By GL GA GA Panel:61.39"X 41.18"
Array:25'9 7/8"X 20'10 718"
I I Surface:27'4"X 23'6"
I f Magic#:Invisimount
I I Legend:
I 1
API 1 AP ® 30 SunPower 350W Panels
I 1 SunPower Invisimount Rail
I 1 ® 72 S51-S Clamps
1 I ji Val Drexel Metals Standing Seam Roof—
I I tl 550S SL-3 Bead 16"OC
L----------i
_ svo Notes-
Number of Roof Layers:1
Height above Roof Surface:4"
Materials Used:S51,SunPower
Added Roof load of PV System-3.5psf
Engineer/Architect Seal:
Aq
H �A
30 SunPower -
2 Meters For Apartment
and Main House 350W Panels 633 ,COQ
OF NE`f`�
jDra'--/By:MMB Drawing#4 of 5
e:5/15/2017 REV:A
_ Drawing Scale: 1/16"=1.0'
(�PGREENLOGICO
ENERGY
GreenLogic.LLC Approved
Gentlemans Ridge LLC
825 Stephensons Road
Orient,NY 11957
Total System Size:10.500kW
MW
W -i Array Size:10.500kW
-i - - 1 Circuit of 12 on a 20A Breaker
+ _!__ .___i.__ ___ . 1 Circuit of 12 on a 20A Breaker
_--' i ! 1 Circuit of 6 on a 20A Breaker
Azimuth:150'
Pitch:34-
Monitoring System:
4°MonitoringSystem:
;
SunPower
oPaneL/Array Specifications:
Panel.SPR-X21-350-BL'K-D-AC
Racking:SunPower Invisimount
Panel:61.39"X41.18"
1—-- I 5'9 7/8"X 20'10 7/8"
--- ----___-_-..----_-,•__-- — -� --------- ; - -----�--------- - Surface:27'4"X 23'6"
Magic#:Invisimount
Legend:
j ! ® 30 SunPower 35OW Panels
- - -- - -- ---- -}-- - — -- - -- --- f--— - -- i—----`--- - --- f _- ; - SunPower Invisimount Rail
__ __ _ _ _ _; _ - -- --•-_ __- .__ . 1 _ . .__- t _- x.^ -- ¢ -- -- - - -- a 72 S5!-S Clamps
f 8�
s—_-------.._.____.-- ----_,.__�----•- -- ------ ----}-;----__�,___-__----' --------- -- -- ----- - ----- -------�------ ---- •`-------6------------------+--------- Val Drexel Metals Standing Seam Roof-
! ! ! 5505 SLS Bead 16"OC
...... ... .. .- _..__. J....... ._. -.___ ---_--.,_ _. ____._�y___._... .__.-__.., _. _`'_.._ -. Notes:
Number of Roof Layers:1
Height above Roof Surface:4"
Materials Used:S51,SunPower
Added Roof load of PV System:3.5psf
Engineer/Architect Seal:
?ti AR
Sy-
X21633 y0�
OF N
D wn By:MMB I Drawing#5 of 5
ate:5/15/2017 REV A
Drawing Scale: 1/16"=1.0'
NEW EQUIPMENT — — — — EXISTING SERVICE
120/240, 1 PH, 3W
PV-SA-1 A
zooa KWH
N • • • 2 1
e e e
AC-COMBINER PANEL
i
AC-CMB-1 PV-5A-2 (PV LOADS ONLY) B AC DISCONNECT
® • ® ® AC-DSC-1
-
a B a I
WR-
PV-SA-3 MAIN
2 1FUSED A B NB 8 B
I
III EGC I -
� N
III EGC
EOc EXISTING AC PANEL
_ L GEC I GETTING
IRREVERSIBLE SPLICE #6 CU —�
PROPOSED 3-LINE ELECTRICAL DIAGRAM
REVISIONS
Gentlemans Ridge LLC G EE L®GIC®
825 Stephensons Road 7p ENERGY
Orient, NY 11957 1.) INITIAL SUBMITTAL WITH APPLICATION ELIMINATING THE COST OF ENERGY
Page 1 of 3 Drawing No: GRLLC-3LD1 Revision: 1 Revised: 5/25/18
EQUIPMENT&COMPONENT SCHEDULE
TAG DESCRIPTION SPECIFICATION
PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-X21-350-AC, 1-CIRCUIT OF 10=MODULES
PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-X21-350-AC, 1-CIRCUIT OF 10-MODULES
PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-X21-350-AC, 1-CIRCUIT OF 10-MODULES
ELECTRICAL LOAD SUMMARY
AC CIRCUITS
TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL
RANGE CURRENT
PV-SA-1 3500 WATTS 211-264 VAC 14.23 A AC 240 V,AC
PV-SA-2 3500 WATTS 211-264 VAC 14.23 A AC 240 V,AC
PV-SA-3 3500 WATTS 211-264 VAC 14.23 A AC 240 V,AC
PROPOSED EQUIPMENT SPECIFICATIONS
REVISIONS
Gentlemans Ridge LLC G E E L G I ®
825 Stephensons Road 7p ENERGY
Orient, NY 11957 ELIMINATING THE COST OF ENERGY
1 ) INITIAL SUBMITTAL WITH APPLICATION
Page 2 of 3 Drawing No: GRLLC-3LD1 Revision: 1 Revised: 5/25/18
EQUIPMENT& COMPONENT SCHEDULE
TAG DESCRIPTION SPECIFICATION
AC-CMB-1 AC COMBINER PANEL 250V, 100A, NEMA-1, 1-PH, 3-WIRE
BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A
BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A
BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A
AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 60A, NEMA-1, FUSED; FUSE RATING: 50
CONDUCTOR SCHEDULE
TAG TYPE CONDUIT AWG. / EGC
A USE-2/PV/UF 3/4" PVC-40 12 / 6
B THWN-2 1-1/2" PVC-40 4 / 4
C THWN-2 1-1/2" EMT 4 / 4
1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND
DERATING FACTORS.
2.) ELECTRICAL CONDUIT TO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS.
3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND
LOCAL CODE REQUIREMENTS.
4.) NOTE:GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER MINIMUM.
PROPOSED EQUIPMENT SPECIFICATIONS
REVISIONS
Gentlemans Ridge LLC G R E E LOGIC®
825 Stephensons Road 0 ENERGY
Orient, NY 11957 1.) INITIAL SUBMITTAL WITH APPLICATION ELIMINATING THE COST OF ENERGY
Page 3 of 3 Drawing No: GRLLC-3LD1 Revision: 1 Revised: 5/25/18
i ' ,, - ag.�bK!ti�-•b�Ya � kY s,�^='Az-..j(:s 1
1;, •'� ... ,s``"vla:�a$C 4 ''„ e ...Ci.. 4's�
RYY iDC•t.\@ P,:: P°n'°° '§T `�!V .�:°I`„`ej•�•v:_;f..:. i Mw.F
`"9s.u."°....
�°9ffip Rv. ap"id \ •\ ';aw"d"�• ^ -3':::. J dr a o �z -�.
:A/y „.; � •r_x. ?.,\,'. �-Yee^• 't ;°^.'a �&, � �`��:, '
p3�•ti. ;3• Tse s ..•'!
Z���� .,r•� .,rs •''",.�,�".,.��._ .s a s',»' "• ��.,Apt `� •- � ' "'"" yqa�',.`;",sem
�^,:zer�b�` ,...%.. "`»a,".. .,...:.:. •.:ti. .._,,: _ _ .w-o-w•� �F'rv,. � d :�'- ., .. gam:S'� 1— "n
"� i=• � �'�;"�` � Waw _� ��V._._�,....w ^�v�`> ��"'�'•"�; .. .--x�'-fi•;,.:.r •,.,� wy��➢f:> eqf'
C
Design-Driven Advantaues
#1 tYtooule ac�ttl�_ir__�rlc f,uentyl ~ � N` � X
• Urlrnatch�ad r�lodtv'e•eliabtllty-'
SERIES
Nc electro yz-,c capac.tr r1:
25-year Complete Ccr`Idehce Warra lty
Ca'fcrnla Rule 21 Phase 1 _cmcllant
Maximize Value for Roof
Size 9}/S;(2x71 for root,no, su ir,,, Irverter
opurnize performance.of ead-mcu;-rle
Expand Deploymr nt Options
romp.ax roofs and partial shading
Small Systems
System expandability Optimize System and Installation Efficiency
Simplify& Speed tnstallation Sur-lower-AC rn' ul_Iles,vjl Ich"1 ;_lac , factory- ltegrdted SunPower
Factory integrated micrc•nverter rn,crorl.verter,orov,de�a revcltlt,c•r clry cor^;:Irlat'c,r cf high ef'Ic ency,nigh
Robust,double-'ocKIrg AC conrectors re';abili,y,and module-evrI JC-1c-AC power conversion Dcs,g,led
Des gn f exibillty offs;e and()r5,e
'
No LC rtr',1g sizing[}rt;reSs
specifically for i.se .1,1ith Invisitvlour*',1 and the S,irPov,er
Fewcr mstalla'aOl•steps than compering Monitoring System,SunPower AC,odu'es enable rapla irstallarlon,best-
sys.etn�
In-c a�;s S'y'stem aesthetics,a,io Ir;tt .eve visibility Into sy�,tc_rn purio'-m_ance
int,lltive camr,lssicr�ng
Pali thlS'-OMCC S V11'111 L`lL,bes',Co' ib'ned Pwver_.,io Product VVo-arlt'J in
Component of Complexe System
the Industry
Built for Lisp wth Sun Po�vver`9'nvisiP:�.ot, it",'
ani.`the SunPower Monitoring sys,om(PVSsx)
S,aperior system rei.abaity and aestF4edcs Grid Support Utility-interactive Smart Inverter
Sur•Po:ver's,ievr--ype D>r:C rTlocli.,le s UL rested-and cert find to J_174'
SA and nrm'IdPs dv?ncec Smart;n•yerter functions S.inPcwe,Tyre D AC
modules a e fully compliant ry,th.he Ca'Porn a Mule 21 °vase 1
regt'Iretr,er,:s,and the Rule 21 grid oro Ile s easy set cit,r'lg
ffi q f } :Urnfr11s510`ilri5, t r
U
.. :' t J
1 vv't l�Gr1POVJ._: vS_)x m.0 111orin�, h:;roti,var,?
sunpower.com
;a', �
JI,
ED
'n
A,
IEIT 1547t' 0 1 "A Ru,e 2'
SRI,Proli e (d e-faij:r so'!ings) ff)JI I r-01-11 I'max
--n,r nor, 1 r-ax —
5851600!605
FF-ecuencv(Hz) 59 5 GO 0 10C,5 -- --
0 85 lead 1 Or*) 0 85 lag
Po.,ver'-actor 0 9C)/-1 00 1 00 -- - -- --
69 VFr
Reactive f)ovver Volt VA-r
V- 1 2--/2-4--0 -2-6-)-4V------
@208 V 183/2,08/228 8 V
i92z-,"j V 1 33 A
NIax (-L.r,en' 0208':' 1 5,'A
@?"0 96 001
L,11-!AC CE_Conversion Ll"icienci
,a)208 V 95 5Ac
1% x @240 V 12(-"I-Igle PIa'e'
P'a
-(�-)20i:5-V --1 0(two I-ole)'I,'.,Ye- -- ----- --
------ 320 W.320 11A
po"Ver
1 No active phaSe N)'ancing`or phase insrallatiors
D
Y21-350-,91.K-D-AC X21-335-BI X?0-327-81-.K-,.)-AC Warranties 25-yP.rl'mltE:d powerwarrancy
25 Year I rTijLea'
3 1)(11 W 33�'hr' '327A' I - -I - --. - -- --y
- ---- - UL:lSt�--`Lo UL 1741 SA
Oov,,er hol,-raiicr +51-0"6 5/
'A
'�RF)s IEEE 1547 2(103,IEEE 1547a 2014,
''are; z� t'451 G 9-',
-,,mP CoJ Wooxr) 0 29r,,V1C Rule 21 Pha,,(--I
I--ee byp,,s5 oiorles PV Rapid S[Iu,,aowr,Ecupmenr
-chile T,)l,,raj icc lnt,,g-ated mofitiv,1�evol mum povior ooint Eat]pmer,t Grounding
!tack-y"
Ul [-)703, JL 9703 lcnne-.CtorS and cables
-•'e", n' (load break dIS(
• UL AC Module(lyF)p 2 f re ra,ing)
Opel,ll.ingTemp, -,'0"F Lo+119'F(-/.0*C 0-65'C)
Cvrt,�cations Fnables instalra-inn.n accordance vgh
241ax Ambient Temp 122'F(50-Q NEC 6`0 6
Wind E,?psf,SCOO Pa,305 kr/,112'ran',R,back
I I -C 690'1 2 Rapid Shutdown ',rside-in(.,
N4 a x Loan
SI I o vv 25_-,s 6 00 0 11 a,6'1 IL"o,,r i "t on, a(jtsi(,E,the a-ay)
-1111 r.)a c,Re s i s i:a rur-- I inch(2!D run)diamete, hall at 52 Mp;l(23 nvs) NEC 690'15 AC Correctors,590 33(A)-(E)"
;:CC and ICLS-0O3 Class B
Sr—
3
-ZIE A When lisec with InvisiMoun, r,-.cving(01-2
,)ICeliS-
96 Morcicrvsz�,,I,mr�'Vaxeon:;en III
High trarisrmssioq trn"Der�d glaiss+,mth am n:,:gr,,ltOd gro,inding and bonding
Fran,class
ccatir", Class A fire rated
reneca✓eRa-zing Outuoor rated MD fe-zL-- -------PoLent a!-ind1jced-d-e,,radai.ail free i
F,arno Clas,:I biacl,anot:1172d(higher'AAMA ratlrj'e
A 280 mm
[11021nl
e I t -15 5 bs-20 6 kg)
Pe,:u,,ir tencled Max
1 3 in (33 rn-i) i fIL
ET
Em
327 W Cop-Pat ed CO a convenricnal orwel orsaae-si,eul arrays1260W,loi,6efflceni, 1107 mm
[43 6 In] 1046 mm m
approx 1 61119,4t$Mole eneigy per Platt(based on OVSys-,oan,iles),0 7515/,,,,,51me, 1 [412 In]
ar 2�1 1)
--gra,latio,-i(',1rT1j)eaU,Z et A stunpmvpr Mod,-j'e Dogroactm,date Sar Jose 30 mm
HS-,,of 11,21n]
ja-ua ry<u ',' &
,1Pk.n.F,at n1 ofer PV Durability I nit ia(I�,e re,i Soki,V o d.j es P i r,:3"I-VI ech P(A er, Knowe
Septc-iber 201S,Camoeau,Z el:--I Suffriver tWodL.-,'&Degrociovon Rate Sanjose(-%2013 GWSU��
1558mm WRACK
17:'cto,y set to 1547d-2014 o,ofile CA Rule-I-proli e se,di,ing corni-riss;omg See tl�,e Elqu'noy [61.3 In] EQUFMWT
iormoreinformAcn LISTED—
S S-a,ida,d I est cond tions(I C00',,,7In'rWijnce,AM 1 5,25'Q NREL callb,ation tanda'tj Pleaso jrjStdlldtIO-I r'SLCtIQf1S fC'detc;,6 Md,,ji.fit.pa&=n--Type 2
TOMS,ur,erit,LAcl,srraro,otage A
See sunpower com,falts for mere refer ecce infoi ation
«dry "' �,. * - .. -- " .. s V ,.�,..�F' "•,,..'`e„",-,^i, LZE; `^'`' •«
a': .':r,::d£.�n fZt'!t ,.`iYa.i> - - ,aiP=°.°• :i.'°^�r3a"c. ,�^�'- .m„ L'
Tib .v�4�;�^.-sr,,'id�r�"' ^',-.'''�:✓, "".ro' rib. r�`<a!' ,s -�xx. ;;w' .t ,•�-„A ;;�• "�'`” yy"'�'.
ei ;.r•:. .•CKs^`•s ,..: _ 5° „5•.a �„.°✓'^"'" ,�;-d
���-R:jy^,)y' � «�"'•-•w,-h�ry �jE� " , ,Nti:."."'"' r ar h � �Y+. .^'„�,'-
Simple and Fast Installation _-
Integrated module-to-rail grounding " !
r
Pre-assembled mid and end clamps i
i_evitating mid clamp for easy placement
Mid Jaw-width taci,iLL es consistent,ever K
module spacing
Simple,pre drilled rad sp4ce -
UL 2703 Listed;ntegrated grounding
Flexible Design _a . 4
Addresses nearly all slooed residential roofs t "'
Design in landscape and portrait
Rails enable easy obstacle rnanagernent ti
Customer-Preferred Aesthetics
#?1 module and#1 mounting aes-,hetics
yes:-in-class systern aestne.ics Elegant Simplicity
Premium,low-profile design
Black anodized components SunPower" InvisiMount"' is a SunPower-designed
Hidden mid clamps and enol clamps rail-based mounting system The InvisiMount system
and capped,flush rails
addresses resident a`sloped roofs and combines faster
Part of Superior System, installation time, design flexibility, and superior aesthetics.
Built-for use with SunPower DC and AC modules
The InvisiMount product was specifically envisioned and
Best-in class system reliabiilty and aesthetics
Corr-ibmc+rnth sunPower modules and engineered to pair with SunPower modules The resulting
monitoring app system-level approacr, will amplify the aes-lheiic and
installation oenefits for boLh homeowners and installers
t?
sunpower.com
• � n 65 r fn�'4.S'e� r �° �Ke
�• p01160110 tell I
Module`%I•.Ild Clamp and Rall Module*/Find Clamp and Rad
Mir
VIE
iv1ldgCl�arnp End Garrlp Pall&Rad Splice Grwnd Lug Assernbiy End Cap
i
j Tei rtfier aLun: _,.O'C to 90'C f• d0'F to 1 s)4'F)
Compc-nent 1JIat PYla, Weignt _— ____ _ _-
3000 r'a uplift
r I Max Load(1_RFD)
- cotrri`orce
I Ild Cla r,o - Black oxide stainless stee•AISI 304 - 63 g(21 oz) 6000 Pa
la —
E 0 CUrnp Black arc0izeo a um Hurn alio,6053 T6 110 9(3 BE oz)
Black arorv,e;,aiurmnum alloy 6005-T6 £?0 gmt(9 07/`t)
! Rall Splice Aluminum alloy 6005-FS 330 gin-,(9 Oz/`t) � 25 year product warranty
I
Ground Lug 304 stainless
106 5 g/rn ''PJarranhes(3 75 0z) 5 year rnish w.al ranty
l Assembly (A2-70 holt,Tin-plated conp4^L,g)
End Cau I Black oce,al(POM)copolyrner 1 10 A g(0 37 oz) -- T
- - i UL 2703 Listed
Certifications
a Class A Fire Rated
Conlpusluur Shingle Fatter Aaachfnent csARM; MAN: 111111::&1gin I
Application Compcis;Unr ShinrlP Rrof fiedking Aaachmen K ;
Curved and I-lot He Roof Attachrnent
UnroPlnuorfare for Other Roof Atta(hrnems l Refer to roof attachment hard,va•e rnanuf,)C:urer's documentation
.1,wule frame in?I Is comoavhle vm.n the Invt,,;AAounr s 'en•i•meq lit na fo,hard rare Ir oroperdEtlily
s?ZOi>St,npuvrer Cnrn.,re:inn r`dl Flights Bese;ven SUNPO:VFk,-he SUPlF'OYJ'R loge,and'h J1SIA10l1NT;tie:•adrnak;o��ri htarr•d
vaderrarK,cr 4rnoow�r Lorp•+avan to otht•i ti ren-ar•,are the proremy ct trei,rospc twe currer, sunpUwer Com
sp»u9cauom;•xtuae:: r..rn,datasrwe.!resub�etzr:rt,ang�w;•�o_tnalc: Document#509506RevC