Loading...
HomeMy WebLinkAbout42540-Z gUfFQI Town of Southold 7/20/2018 a P.O.Box 1179 d' 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39782 Date: 7/20/2018 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 495 Cases Ln., Cutchogue SCTM#: 473889 Sec/Block/Lot: 109.-6-9.6 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/29/2018 pursuant to which Building Permit No. 42540 dated 4/5/2018 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels on existing one family dwelling as applied for. The certificate is issued to Zablocky,Kim&Patricia of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 42540 5/30/2018 PLUMBERS CERTIFICATION DATED Authorized Signature TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE ,py .► SOUTHOLD, NY °l. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 42540 Date: 4/5/2018 Permission is hereby granted to: Zablocky, Kim 495 Cases Ln Cutchogue, NY 11935 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 495 Cases Ln., Cutchogue SCTM # 473889 Sec/Block/Lot# 109.-6-9.6 Pursuant to application dated 3/29/2018 and approved by the Building Inspector. To expire on 10/5/2019. Fees: SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 �16u Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957)non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial $15.00 Date. 3 29Azo 1(as New Construction: Old or Pre-existing Building: ✓ (check one) Location of Property: Aq'S­ LtA, Caczlx� House No. f Street Hamlet Owner or Owners of Property: I M ZA&_0 C-(,---{ Suffolk County Tax Map No 1000, Section GI Block co Lot Subdivision Filed Map. Lot: Permit No. � Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: '/ Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ 50 r- X Applicant Signature ®��OF SO(/TyQI � o Town Hall Annex Telephone(631)765-1802 54375 Main Road & Fax(631)765-9502 P.O.Box 1179 • �Q roger.richertCab-town.southold.ny.us Southold,NY 11971-0959 Q�yc®UIV 00�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Kim Zablocky Address: 495 Cases Lane city,Cutchogue st: New York zip: 11935 Building Permit#: 42540 Section: 109 Block: 6 Lot- 9.6 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Element Energy LLC License No: 52689-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel AIC Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures �] TVSS Other Equipment: 10.56 KW Roof Mounted Photovoltaic System to Include 33- LG 320 Panels with 33-Enphase Micro Inverters. Notes, Inspector Signature: Date: May 30, 2018 0-Cert Electrical Compliance Form.xls OXES cou 4 W (OF 00uw MOLD BuMooma [DEPT© 766-1802 INSPECTION E FOUNDATION IST ROUGH PLBG. FOUNDATION 2ND MULATION FRAMING / STRAPPM FINAL HREPLACE & CHMNEV LALfjRE SAFETY MSPECTION FIRE RESMANT CONSTRUCTION FIRE RE&STANT PENETRAMN ELECTMCAL (ROUGH) ELECTRICAL (RNAL) cc 4G BAU FEE Z--/ WGI CLAUDIO SCIANDRA, 'P.E. 5 Wesleyan Court- Smithtown, NY 11787-3011 • (631)543-2953•fax(631)543-1526 Cell.631-747-7497 E-mail:Ics4dCa-aol.com Wednesday, July 11, 2018 Town of Southold 53095 Route 25 PO Box 1179 Southold, New York 115971 - - Re: Certification-Letter-Thirty Three(33020 W PV Roof Top Solar Panel Array, 10.56 kW Total Output,for Zablockv Residence—495 Cases Lane Cutchogue, New York 11935 1 have reviewed the solar energy system installation in the subject topic on 05/31/2018. The units have been installed in accordance with the manufacturer's installation instructions and the construction drawings approved by the Building Department of the Town of Southold. The solar panel installation is in compliance with the requirements of the 2015 International Residential Code, the 2017 New York State Supplement to the Uniform Code, ASCE-05 and NFPA Standard 70 "The National Electrical Code." Markings in accordance with Section 690.53 of the National Electrical Code are provided. To my best belief and knowledge, the work in this document is accurate, conforms to the governing codes and standards applicable at the time of submission and conforms with reasonable standards of practice with the view to the safeguarding of life, health, property and public welfare. Sincerely, of Nevi, yo ® D �2s�o 0110935 A ��`� JUL 2 0 2010 Luigi Claudio Sciandra, Professional Engineer. A�®FESSIOBUILDING DEff. TOWN OF SOUTHOLD FIELD INSPECTION REPORT7 DATE COMMENTS FOUNDATION (IST) y ------------------------------ 'FOUNDATION (2ND) z o -14 C � ROUGH FRAMING& m PLUMBINGy INSULATION PER,N. Y: H STATE ENERGY CODE FINAL Nt ADDITIONAL COMMENTS, Lir 1 I r J�-' o t � Z rn • o 0 - d b H Ii - * TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying9 TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX:(631)765-9502 S ey Southoldtownny.gov PERMIT NO. V heck Septic Form NYS.DEC Trustees C O Application Flood Permit Examined 20Single&Separate D D Truss Identification Form MAR2 9 2018 Storm-Water Assessment Form Contact: Approved ,2016 11�1� Disapproved a/c f ', -,,t+ l:` 's"•: � �tUtU� .rONWON®F Phone: –1gqS Expiration 20 Building or APPLICATION FOR BUILDING PERMIT Date 3 2 2b l g,20 INSTRUCTIONS a This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Perrmt. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) E nra sr k-,WU.0-fAy LLC. (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder Name of owner of premises V—1 m J. (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. -Z LP M18 Other Trade's License No. 43 J3 S61—1 1. Location of land on which proposed work will be done: 495 Lm:�es Lw,� f Lu-rc.No(,gys vJ-4 I ig35 House Number Street Hamlet County Tax Map No. 1000 Section Block (0 Lot -1 . ca Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy tZ�S)ptc:i,�1®-1— 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work S�Qy 4. Estimated Cost Fee wc-, (Description) (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated / 12.Does proposed construction violate any zoning law,ordinance or regulation YES_NO Y 13.Will lot be re-graded?YES_NO ` Will excess fill be removed from premises?YES_NO "'' 0(rot6 14.Names of Owner of premises 6A7,A Address M C w,""Phone No Name of Architect Address Phone No Name of Contractor EtMPr1" y LLL Address V ®6/ Phone No. 1031- -I-A-AC19 S merit eCUCILy 1 AS2- 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16 Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO *IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS COUNTY OFS� 3 70 , n I A I CLlain— being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the (Contractor,AgOnt,Corporate Officer,etc.) ti -C of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; {, that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. o� Sworn to before me this 1?7- day of /hate,&/ 20 /9 � - IL - Notary Public Signature of Applicant pF St3�jlyv Town Hall Annex Telephone(631)765-1802 _ 54375 Main Road y (631}765 g5 P.O.Box 1179 Q rogerAchertl tOwn.so6utR5o&ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD ' APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: -31t���� _ Date: 3 �� t Company Name: LL P_ Name: Jnnl M1�sNtc,� License No.: 5'L to eq ^ M-1v Address: -74-1 p Sou kit-. A\jv- cam, Phone No.: LPS 1 - -1-1 q - "1°I q 3 JOBSITE INFORMATION: (*Indicates required information) *Name: V,1 iN *Address: d8s CaR;eS �-a C�rtU-lo(�cvt✓ i f`� 119 5 ' *Cross Street: N1,r t-A *Phone No.: Ca3 b1c) - cpiLolo Permit No.: ZILL— Tax-Map j LTax•Map District: 4000 Section: I O Block:�_ Lot; CJ. to *BRIEF DESCRIPTION OF WORK(Please Print Clearly) 1rcST .c- Tion UG ��- 1Mt7ur�cS"� Som Pel MiJ�yt�S f (Please Circle All That Apply) *Is job ready for inspection: YES Rough in Final *Do you need a Temp Certificate: YES Temp Information(If needed) 'Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead ' Additional Information: PAYMENT DUE WITH APPLICATION _cam. ec q/b 67 f i 82-Request for Inspection Form ffco �Gy r�''� � f BUILDING DEPAR MENT-Electrical Inspector 2 TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX(631) 765-9502 roger.richertCa-)town.southold.ny.us APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: 14116M L V4TOr4 Date: SA.D. Company Name: E l_L Name: ,.� M 1 Mlr-49CA--" License No.: 52.(PCBA-Ms email: Address: -10- v A6 ' -t-t-tT t4 114 1 KAS'L Phone No.: UZI - Z Cl- -1 CiA& JOB SITE INFORMATION: (All Information Required) Name: -V-1 M --z-�' C-d—q Address: 41S �, 5 Ltl LZTKA-66SUVi Cross Street: Mtr.1, e.p. Phone No.: (0271.1-101- Bldg.Permit#: 4254p email: j\AIt4_c�-Js CM, Fax Map District: 1000 Section: QR' Block: (D Lot: q.to BRIEF DESCRIPTION OF WORK(Please Print Clearly) Sot.O. P 11�i5 t Lp ot� — TutA�- �i`OSt to StZ�= 1�.5Lo t�.Nl ( 3� L.C� 32ots1ti-�L[VD%N EA.) (33) I N,RiAe--,i5 lGOO-ISD- 2. US M1C. D 114\1e Circle All That Apply: Is job ready for inspection?: YE NO Rough In 'nal Do you need a Temp Certificate?: YES( Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service-Fire Reconnect- Flood Reconnect-Service Reconnected -Underground-Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: —TE-115 A, A1,,1 VPt>k--CS 'TCC AI CTl�i�rV PAYMENT DUE WITH APPLICATION 82-Request for Inspection Formas 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road cn Fax(631)765-9502 P.O.Box 1179 G • Q Southold,NY 11971-0959 �® a lyc®Uf�IT`I,N� BUILDING DEPARTMENT TOWN OF SOUTHOLD May 31, 2018 Element Energy LLC 7470 Sound Avenue Matti tuck, New York 11952 RE: Zablocky, 495 Cases Lane, Cutchogue !� C � NOTE: Certification of solar panel installation required from architect or engineer TO WHOM IT MAY CONCERN: The items marked below are required to obtain your Certificate of Occupancy. Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. (Electrical Inspector 631-765-1802) A fee of$50.00. Final Survey with Health Department Approval. Plumbers Solder Certificate Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. (631-765-1802) Final Landmark Preservation approval. Final Elevation Certificate required. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT: 42540-Z Solar Panels New York State Insurance Fund Workers'Compensation&Disability Benefits Specialists Since 1914 8 CORPORATE CENTER DR,3RD FLR, MELVILLE,NEW YORK 11747-3129 CERTIFICATE OF WORKERS' COMPENSATION INSURANCE "^^^"^ 821045711 %�i , ROBERT S FEDE INSURANCE AGENCY23 GREEN ST STE 102 HUNTINGTON NY 11743 Scan to Validate POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY SYSTEMS LLC TOWN OF SOUTHOLD 7470 SOUND AVENUE PO BOX 1179 MATTITUCK NY 11952 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 11455663-3 1 82803 06/08/2017 TO 06/08/2018 12/8/2017 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 1455 663-3, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUP DIRECTOR,INSURANCE FUND UNDERWRITING DATE(MM/DDNYYY) A�f> CERTIFICATE OF LIABILITY INSURANCE 12/08/2017 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME ROBERT S.FEDE INSURANCE AGENCY PHONE - - FAX - - 23 GREEN STREET,SUITE 102 E-MAIL Ext: AIC No HUNTINGTON, NY 11743 ADDRESS: ROBERTS.FEDE INSURANCE IHULISNSURER S)AFFORDING COVERAGE NAIC# INSURER A INSURED INSURERB STATE INSURANCE FUND INSURER C ELEMENT ENERGY SYSTEMS LLC INSURER D 7470 SOUND AVENUE INSURER E. MATTITUCK, NY 11952 INSURER F COVERAGES CERTIFICATE NUMBER: 5,635 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LTR SD WVD POLICYNUMBER MM/DD MMIDD LIMITS COMMERCIAL GENERAL LIABILITY hbd 10027165 7/14/2017 7/14/2018 EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE u OCCUR X DAMAPREMISES Ea occuGES RENTED rrence $ 100,000 A MED EXP(Any one person) $ 5000 PERSONAL&ADV INJURY $ 1000000 M'OTHER L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 2,000,000 POLICYECT LOC PRODUCTS-COMP/OP AGG $ 1000000 $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB HCLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N WC 14556633 8/08/2017 8/08/2018 X STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVEE L EACH ACCIDENT $ B OFFICER/MEMBER EXCLUDEDI ❑ N/A (Mandatory in NH) E L DISEASE-EA EMPLOYEE $ If yes,descnbe under DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ NY State Disability WDL10274774 9/01/2017 9/01/2017 statutory DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE 2o&-k tS. Fede, Sr. ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and loqo are registered marks of ACORD AP R. VED AS NOTgo DATE: S. , B p # RETAIN STORM WATER RUNOFF FEE: BY, PURSUANT TO CHAPTER 236 NOTIFY,BUILDING DEPARTMENT AT OF THE TOWN CODE. 765-1802 SAM TO 4 PM. FOR THEA FOLLOWING INSPECTIONS; 1: FOUNDATION - TWO RE0019ED" FOR POURED CONCRETE <'- ELECTRICAL ' 2. ROUGH =�RRAMING &-PLUMBING INSPECTION REQUIRED 3. INSULATION'' 4. FINAL CONSTRUCTION MUST BE-COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENT8 OF THE CODES OF NEW YORK STATE- NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF --&=m in D eWWBA--� OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY MIC INVERTER ENPHASE 106 GO 2 U5 I DE51GN 6 DRAFTING BY 40 VAC,0 9G A SOLAR ARRAY(105G I*) 97%CEGWdGI-n EFF 1 JAMIE MINNICK (331032ON r.ASf-0NRMOW18 NEMAG,ULUSTEDGYP)' SOLAR MODULE f33)ENPHASf N]660.2115 MICRdiNVER(ERS NABCERTIFIED 05511 1112-129 I Fd�Fd I—idl Id— Fi&-I Z IE_9 E Z I REVISIONS c c c c -- -- -- -c -_r_- - -- '- - c ENPHASE t DESCRIPTION DATE REV I -- -- -- -- -- -- -- -- -- -' -- -- -- - RANCH TERMINATOR �_ ___________ _____ c c c c c c c c c c c ORIGINAL 03-12-2018 L REVISED 04-09-2018 A I I �Fd 002 _ =JaTal _ Z ---------------- i -----I I TO UTILITY GRID I I I I I CONTRACTOR N BI-DIRECTIONAL I - UTIUTY METER 1-PHASE,240 V 0 ELEMENT ENERGY, LLC c ---- - --- --- - - --- ---- LI N 7470 SOUND AVE ENPHASE BRANCn CIRCUITCAB E nP MATTITUCK, NY 1 1952 o-�l— -- - LICENSE#43889-H LICENSE#52689-ME I I AC COMBINER BO% I I I nizeo�euif�Bzrov mA i I I I MAIN SERVICE DLSLONNEGT 240 V.200 A G N LI A ICI N LI ^ T N L' LI PROJECT NAME I I I LI LI 1 r-� W u m MarFi SSFR�I��sra.'.M LI LI v W V J LU Z G N LI Q Q I LI LI � L L2 MAIN SERVICE PANEL iV 1 maw W 40— N z00 Ai W 11 ' Q D I 1 1 Ddr TING GROUNDING-------------- I ELECTRODE SYSTEM O 1^ O WIRE b CONDUIT SCHEDULE J CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED VdGge Drop(P 1�J IDP ORIGIN DESTIMATION SIZE PER POLE QUANTITY DERATE INSULATION SIZE QUANTITY INSULATION (CWAU TYPE 5RE TEMP DEBATE DISTANCE ISRN31 o 15{BN�+N3q STRING COMBINER PANEL AWG B IO I G 3 O B U5E-2JPV W- AWG k8 1 BARE CU FREE AIR 1' 70�C O C, 1 1 O PT O87. i L!1 OR EMT o V 2 COMBINER PANEL AN SERVICE PANE AWG A4 1 3 I ROMIX AWG#8 I THWN 2 CU PVC 1' 45°G 057 50 PT O 6% � E ELECTRICAL NOTES nl SNEET NAME I) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOP ITS APPLICATION CALCULATIONS FOP CURRENT CARRYING CONDUCTORS LO O 2)ALL CONDUCTORS SHALL BE COPPER,RATED FOR 600 V AND 90-C WET ENVIRONMENT #I PV Source Circuit Wire Ampaaty Calculation PEB 1 4 t 3-LINE DIA. 3)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY A 0 TO,AND LOCATED AS CLOSE AS PO551BLE TO THE NEAREST RIDGE,HIP,OR VALLEY [NEC 690 8(B)(1)] (Isc)'(#of stnngs)'(I 56)= 17 97 A CONFIGURATION 4)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL AWG#10,ampaclty a Temp Derate'Conduit FIJI Derate=20 8 A Modules COMPLY Stn 12+12+9 Z COMPLY WITH NEC 110 26 20 8 A> 17 97 A.therefore DC wire size 1s valid 5)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS CONTRACTOR SHALL Modules per Inverter I #2 Inverter Output Wire Ampaclty Calculatlon Number of Inverters 33 DRAWING SCALP FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACE55ORIE5 TO FULFILL Inverter Output Circuit OCP Calculation(Inverter Imp)'(I 25)=39 6 AI APPLICABLE CODES AND STANDARDS AWG#4,derated ampaclty'(Temp Derate)'(Condult FIJI Derate)=60 9 A Record low tem -1000 6)WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, 60 9 A>39 6 A,therefore AC mire size 1s valid Voc Temp Coefficient -0 27%40C _ H I.7. . THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY DC SYSTEM SPECIFICATIONS CALCULA O I V 7)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE 8)MODULE GROUNDING CUPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE Operatincj Current 9 6 A =(#of stnn 5)'(Im ) SUPPORT RAIL,PERTHE GROUNDING CUP MANUFACTURER'S INSTRUCTION OFcG3tIM VOltal3a 33 3 V =(#modules In senes)'(Vm) 9)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G E C VIA WEEB LUG Max System Voltage 47 7 V =R modules 1n series)'[(((-##�VTC'OI)'(Lo Temp#tlaC-25))'Noc))+Noc)] SHEET NUMBER OR ASCO GBL-4DBT LAY-IN LUG Short Circuit Current _ 12 7 A =(#of stnngs)'(Isc)'(I 25)per Art 690 8(A)(1) 10)THE POLARI-TY OF THE GROUNDED CONDUCTORS 15(positive/negative) Q- I \ _ / OR AC SYSTEM SPECIFICATIONS I v 1 O)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690 35 Max AC Output Current 39 6 A O eratm AC Volta e 240 V is NSTRUCTION NOTES DESIGN#DRAFTING BY: 1 .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE JAMIE MINNICK MANUFACTURERS INSTALLATION INSTRUCTIONS. NABCEP CERTIFIED 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3K RATING. 051112-129 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. ARRAY # I 24 MODULES 7—II REVISIONS 2G°PITCH `-1 DE5MPTION DATE I REV GG°AZIMUTH d 1-01 oRrcrP os-12-20Ia 3G"x 3G" CLEAR GROUND ACCESS TVP. 1 I b ✓i/: �`/, Jam'`•'! /;. r 'r +' •'�':✓/�r !//+/�`'>r f moi''','/ ' /• ,'J ' `/'>" till ;�.: °,,tf.'/'„r:r�;^':�,'`� + ,f, /.36rFIf,�E',STrTBAC/IC•GL�AR�PPATti:-.,/J, ., ;F,,,f,.;�;-,; ;,J„�,;r;,' f�/i'+''f !f of//,°!`f' !'�✓''�l,r,,'•.•'IrF+J'r',',,?,`�rr,J•/,/'r'••�///, J•,• ,�s .,l.,r;,. ,.�%f/�^:/i CONTRACTOR ELEMENT ENERGY, LLC. 77 7470 SOUND AVE MATTIT UCK. NY I 105' LICENSE# 43889-H LICENSE# 52G89-ME !,'lam.,/.f ///i• ! `r l,,,f`'rv,/. i; d/f!!%jJ'l�/%. 'J '/ :jj/fr�r �/'' .'!/�:':J;r�!/.%lF/;,i/,•/%,•+,�/'! !''�/!1/,�/'( '�.r! /f' �r '`! / /,' 'r '/", J J: ✓ .'i''''"!r r'd ./':'_' J,+'' e; ;r PROJECT NAME ;_n :; 'r, `„•,,,•,j'. -:: ''`�'iif�'a,,�r,,lr,, Irr.E,'SEF6ACK`G f�(DG��-r• � ✓'+ Jl:r_ .!;'` ;/"/� �;:i•f'``}:' / l;�r;•;�.� I �/�)—� II .�, [�.7,/ �!. /%' f,iY;r:,� .t;/,%! fes' ✓'/;;, ;!;','i. { fes' '.'<i ./f,, iF, /^./I !rl I / '/ i ! V'/�/ ��/•�} W �s W — ;i,! ADDITIONAL ROOF VENTING 0 ACCESS AT GABLE END J �- ADDITIONAL ROOF VENTING ACCESS AT GABLE END— ' IJ-1 0 Ln LEGEND ';:i,,r{✓�!h,�,;' `J;;;.��/J //, Ill ( l ° �EXIS11N0 UTILITY METER MAIN SERVICE PANEL NEW PV SUB-PANELS 2 0 4 pyo A/C DISCONNECT COMBINER INVERTERS 5I1EE7 NAME d nh '' i✓r :;' '' I a (HND ELECTRODE �°� +!?% !• :/-' !� I PV MODULE ROOF D ETA I ,o ” coARRAY #2 —RACIONO RAIL o�ti 9 MODULES ATTACHMENT POINT 26 __°PITCH -RAPIERS 246°AZIMUTH ))K s–RCOF PITCH ANGLE DRAWING SCALE ®SUNRUN METER CONSTRUCTION SUMMARY N .T,j (33) LG 320N I 5 PV MODULES (66.38”X 40°) (I),50LAREDGE SF --INVERTER PLUMBING VENT K A (1)SOLAREDGE SE3000H-US INVERTER' CHIMNE ®SKY LIGHT (84) ATTACHMENT POINTS @ G4,°• OC MAX. ®COMPOSI SHEET NUMBER (369.2) LF IRONRIDGEXR100 MOUNTING SYSTEM. OCIODD CONDITION IN� fv-3 ROOF TYPE= ASPHALT SHINGLE. - P07EN71AL SHADING ISSUES �7"/REMOVE AS NECESSARY NFnAse lc,:ao-zu - DE51GM t DRAFTING BY V4 4A _"RARLAvt 1J IG BM Pl%GECft `e ell �- JA MEMINNICK iii FurwMe x%eoi 5inear�iERrce.= u_+nAEULuS*fG(NP) OVR MODULE NABCEP CERTIFIED 9 051112-129 v v v ENPnASE REVI51ONS T. , 1 DESCMMON DATE REV _ _____________________ _ 1 TeRM1NAioR CJG'NAL 03-122019 RFVLSED :N-092JId A I I I 1 _ _ _ lid _ _ _ _ _ _ _ _ ------------------- IL _______________ , I I TO UTILITY GRID I I I I I LI L2 N CONTRACTOR - ___ - - O N.DIRPCTIONAL UTILNI'METER }- ------ -- -- I.IN59,24oV ELEMENT ENERGY,LLC - --- ----- -"- -- '-- u N 7470 SOUND AVE I 1 ENPHASE BRAND 1 1 1 1 mRD)ar.�BiETrP MAT7ITUGK,[IY 1195 LICENSE#43889-H LICENSE#52689-ME I I I I I 1 Ac canNUMER Box I I I A PROJECT NAME - --J I �/'� IL j R LI LI rL�J 7 _ 1 7A -------__-J - LU NrgJ I VA,.kRv[.Picallr LI LI Z W W V 1 Z - 1 N LI LI Q - ^ L MN N SERVICE PANEL ________________________________'T!Jj--------_--------------------------------------------------------- G I Y U V e 1 I I ELECTt30 E55YSTEEM� V _ O Ln O WIRE t CONDUIT SCHEDULE CIRCUIT CIRCDT CIRCUIT CONDUCTOR CONDUCTORS CONDUCTOR CONDUR f1LL CONDUCTOR GROUND GROUND GROUND TWE CONDUIT CCNDNT AMNEM TE1A ESTIMATED Vdbg•pop(% V IDI ORIGIN DESTINATION 512E PER POLE OUANTRY GELATE IN5UTATION 51R OVAWIW INSULATION cc- TWE 51. TEMP DEBATE D5TANCE G STRING CONOM&NEL PANELNNENSERVRPANEL —110 1 G OB USE-yw wve AWS/B UARE CU REE NR 0065 ve IIDPr OB% V OP EM eJ CICE PAN AAG 1 3 ROME% GPB Tnww2 CU P/C 1 47 Ob] 50F' OG% - _ ELECTRICAL NOTE5 5HEET NAME I)ALL EQUIPMENT TO BE L15TED BY UL OR OTHER NRTL,AILD LABELED FOR 1T5 A"FLICATIOII CALCULATION5 FOR CURRENT CARRYING CONDUCOR5 2)ALL CONDUCTORS 5HALL BE COPPER RATED FOR 600 V AND 9OuC WET ENVIRONMENT 3)WIRING,CONDUIT,At ID RACEWAY5 MOUNTED ON ROOFTOP5 SHALL BE ROUTED DIRECTLY #I PV 5ource Groult W1re,Ampaclty Calculation 3-LINE DIA. TO,AND LOCATED A5 CL05E A5 POSSIBLE TO THE NEAREST RIDGE.HIP,OR VALLEY [NEC G90 8(8)(1)7 (1-)-(#of stnngs)'(1 5G)= 17 97 A CONFIGURATION 4)`NORKII IG CLEARAI ICF5 AROUND ALL NEW AND ffXE3TIIIG ELECTPICAL EQUIPMENT 5NALL AWG#to ampaaty'Temp Dente'Conduit F111 Dente=20 8 A Modules per 5trm 12+)2+9 COMPLY WITH tIEC I 10 2G 20 8 A>17 97 A.therefore DC v Ire ece e,vaLd 5)DRAWING5 INDICATE THE GENERAL ARRANGEMENT OF 5Y5TEM5 CONTRA.CTOR5HALL Modules er Inverter FUR1115H ALL NECE55ARY OUTLET5,5UPFORT5,FlTTING5 AI ID ACE550PJE5 TO FULFlLL #2 Inverter Output W1re Ampaclty CaIcuWGon Number of Inverters 33 Inverter Output Grit OCP Calculation(Inverter Imp)'(I 25)=39 G A DRAWIIIG SCALE APPLICABLE CODFJJ AND STANDARDS AWG#4,derated amps W(Temp Derate)'(Condult 511 Derate)=GO 9 A ReGord low temp -I(PC 6)`NE Co SIZES OF JUNCTION BOXES,ACCORDING AND CONDUITS ARE NOT SPECIFlED 60 9 G for Voe Tem Coeffiaent -0 27%N�C N.T.-9. THE CONTRACTORTIoN55HAUL SIZE THEM ACCORDINGLY DC 5Y5TEM SPECIRCATIONS CALCULATIONS 7)ALL WIPE TERMII IATIONS SHALL BE A 5TALLEPRO JATET'LABELED AND READILY VISIBLE OV[E O 1r -1 Current 9 6 A ={#of strin s)'(Im) 8)MODULE RAIL PER CUPS UN IN INSTALLED BETWEEN MODULE FRAME AND MODULE 5UPPORT PAIL PER THE GPOUNDING CLIP MANUFACTUREF,5 IN5TPUCfl011 DE O eratln Volta a 33 3 V =(#modules 1n senes)'(Vm) 9)MODULE 5UPPORT PAILTO BE BONDED TO COI ITII IUOU5 COPPER G E C VIA WEEB W G Max System Voltage 47 7 V =(#modules 1n renes)'[(((-ff##%NRC'Q I)'(LO Temp##¢C-25))'(Vice))+(Voc)J 5HEET NUMBER OR IE POLARITY GBL-4 DBT E GR LUG Short GrcuR Current 12 7A =(#of etnngs)=Ose)'(1 25)per Art 690 B(A)(1) I O)THE POIARIN OF THE GROUNDED CONDUCTORS IS(posltrve/negative) PV-5 OP, DAC SYSTEM SPECIFICATIONS 1 O)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AIID SHALL COMPLY WITH NEC G90 35 MAY 3 D0 Max AC Ou ut Cument 39 G A O nGn AC Volta e 240 V BUMDING DE Yi TOWN OF SOUTHOLO LUIGI CLAUDIO SCIANDM, P.E. 5 Wesleyan Court• Smithtown, NY 11787-3011 • (631)543-2953 -fax(631)543-1526 E-mail:lcs4d@aot.com Friday, March 23, 2018 Element Energy Systems 7470 Sound Avenue Mattituck, New York 11952 Tel. 631-779-4004 Attn.: Mr. Mike Lawton Engineer/Project Manager Re: Thirtty Three (33) 320 W PV Roof Top Solar Panel Array, 10.56 kW Total Output, for Zablocky Residence—495 Cases Lane Cutchogue, New York 11935 Dear Mr. Lawton: Pursuant to your request, I have reviewed the following information regarding the subject roof top solar panel array: • Cover Sheet with Site Visit/Verification prepared by E2Sys representative identifying specific site information including size and spacing of rafters for the existing roof. • Design drawings of the proposed system to include site plan, roof plan, mounting details for the solar panels.This information was prepared by E2Sys and will be utilized for approval by the Town of Southold and for construction of the proposed system. Based on the above documentation, I have evaluated the structural capacity of the existing system to support the additional loads imposed by the solar panel arrays and offer the following comments: The existing roof type is provided with asphalt shingles, '/"plywood decking,2"x8"Douglas Fir rafters at 16" on center, 2"x8" Douglas Fir ceiling joists at 16" on center,with 260 roof pitch for array#1, 2"x 10" Douglas Fir rafters at 16"on center, 2"A" Douglas Fir ceiling-joists at 16" on center, with 260 roof pitch for array#2, 2"x4' Douglas Fir collar ties at 64"on center(for arrays 1 and 2). Our review of the exterior roof indicates no signs of settlement or misalignment caused by overstressed underlying structural members. Structural Analysis: The structural analysis has been carried out using the following design criteria.. Design wind speed: 130 mph 1 Ground snow load: 20 lbs/sq. ft. Solar Arrays 1 and 2 dead load: 2.8 lbs/sq. ft. Total Weight of Array 1: 1254.6 lbs Total Weight of Array 2: 474.0 lbs The above values are within acceptable limits of recognized industry standards for similar structures. The structural analysis, performed for the existing structure and for the solar panel arrays, utilizing the above design loads, indicates that the existing roof rafters will be able to supports the additional panel weight without damage, if installed correctly. The onsite inspection and the photographs show that the roof framing is in good conditions. However, the dwelling owners are to be made aware that long term build up of heavy snow conditions may produce deflections in the roof structure. If any deflection is noticed, than it is recommended that the solar panels be cleared of accumulated snow more than one (1)foot deep over a period of one week. If no deflections are visible under any snow loading over a period of time, then there is no need to clear the solar panels. Based on the above evaluation, it is the opinion of the undersigned professional engineer,that with appropriate solar panel anchors being utilized,the roof system will adequately supportthe additional loading imposed by the solar panel arrays. This evaluation is in conformance with the 2015 International Residential Code, 2017 New York State Supplement to the Uniform Code, SEI/ASCE 7 "Minimum Design Loads for Buildings and Other Structures", current industry standards and practice and based on documentation and data supplied by E2Sys at the time of this report. Should you have any questions regarding the above or if you require additional information,do not hesitate to contact me. Sincerely, ugi Claudio Scia dra, P. E. OF NEW yo Sclg v � a 2�t�0 660935' AROFESSIONP� 2 SCOPE OF WORK f TO INSTALL A 10.56 KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT THE ZABLOCKY RESIDENCE, LOCATED _ ,r'`� - JAMIE MINNICK N JADESIGN m DRAFTING BY; AT 495 CASES LANE,CUTCHOGUE, NY 1 1935. THE POWER GENERATED BY THE PV SY5TEM !� CEP CERTIFIED WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXI5TING ELECTRICAL SERVICE os I 112-I 29 EQUIPMENT, THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. e REVISIONS SYSTEM RATING DESCRPTION DATE REV ORIGINAL 03.12.2018 10.56 kW DC 5TC poi EQUIPMENT SUMMARY of "E`'"yo c.scIgNo 33 LG 320N I K-A5 PV MODULES I SOLAREDGE 5E7600H-U5 INVERTER I SOLAREDGE 5E3000H-U5 INVERTER ay mato RD I IRONR(DGE XRI 00 MOUNTING 5Y5TEM - CONTRACTOR SHEET INDEX sF4o 060835 �,� ELEMENT ENERGY, LLC. PV-I COVER ARORE&S1000 PV-2 SITE PLAN - , 7470 SOUND AVE PV-3 ROOF PV LAYOUT MATTITUCK, NY 1 195 PV-4 STRUCTURAL)DETAILS 4 SECTIONS LICENSE #43889-H PV-5 3-LINE ELECTRICAL DIAGRAM Ar s LICENSE# 52689-ME GOVERNING CODES - 2014 NATIONAL ELECTRICAL CODE. 2015 INTERNATIONAL RESIDENTIAL CODE AND NY5 2016 SUPPLEMENT, PROJECT NAME UNDERWRITERS LABORATORIES(UL)STANDARDS OSHA 29 CFR 1910,269 �a W Ln GENERAL NOTES PROJECT LOCATION z Lu 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT LL_I THE 51TE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK . AGREE THE SAME. $- 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIREDLu APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, .CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE I. Q 10 LuINSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM � -wk� ,���;,;� -� �` `-M ;. � 4 ,� •„ � U AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED, CONTRACTORS LIABILITY, WORKMAN'S COMPENSATION, U R THE PURPOSES 3, ALL WORK SHALL CONFORM CONSTRUCTION CODE AND -x*' ' ® Ln O ALL RULES AND REGULATIONS OFF COMPLETED OPERATION, ETC, ADEQUATE FOR, THE RESPONSIBLE COMMENCING WITH WORK. OF THI5'PROJECT AND FURNISH PROOF OF SAME PRIOR TO JURISDICTION, U 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS I 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING SAFETY ONTHE JOB SITE DURING THE WHICH DISAGREES WITH THAT A5 INDICATED ON THESE PLANS; ;ak a N CONSTRUCTION F- 1 THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE PHASE TO COMPLY WITH THE REGULATIONS U ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND CONTINUE WITH THE WORK, HE SHALL A55UME ALL HEALTH ADMINISTRATION, TH15 SHALL INCLUDE, BUT ARE NOT _ RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, _ '* 5,ALL STRUCTURAL STEEL SHALL BE LATE SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY TEAND SHALL BE SCAFFOLDING, STAIRS, ETC„ AS WELL AS PERMANENT t `Ft SHEET NAME FABRICATED AND INSTALLED AS PER LAST A,LS.0 SCAFOL SPECIFICATIONS. CONSTRUCTION, 6,ALL ELECTRICAL WORK SHALL IN ACCORDANCE WITH N.E.C. 12, FIGURED DIMENSIONS SMALL GOVERN. 00 NOT SCALE UNDERWRITERS APPROVED AND IN BOARD FIRE DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING � COVER NYS CODES�REGULATIONS CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS AND CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S COMMENCING WITH WORK. CERTIFICATION OF THESE PLANS, 13.CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS DRAWING SCALE 8,THESE DRAWINGS AS IN6TRUCMENT5 OF SERVICE ARE AND WORK FROM THE 51TE AND DISPOSE OF IN A LEGAL MANNER ON SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE A WEEKLY 5A515 OR SOONER IF CONDITIONS WARRANT. N e a o PROJECT FOR WHICH THEY ARE MADE 15 EXECUTED OR NOT. 14.AT THE COMPLETION OF WORK,THE SITE TO BE CLEARED THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS, THE FACILITY 15 TO BE EXTENSIONS TO THI5 PROJECT LEFT BROOM CLEAN AND WORK 15 TO BE COMPLETED TO THE 9, CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. SHEET NUMBER RESULT OF HIS WORK, AERIAL VIEW F r � DESIGN$DRAFTING BY:- JAMIE Y:JAMIE MINNICK NABCEP CERTIFIED ,ell051112.129 REV15ION5 DESCRIPTION DATE REV 3G"x 3G" CLEAR GROUND ACCE55 TYP. - - - ORIGINAL 03-12-2016 I 30 FIRE SETBACK CLEAR PATH f CONTRACTOR 71111` 211 ELEMENT ENERGY, LLC. 7470 SOUND AVE MATTITUCK, NY 1 1952 LICENSE# 43889-H LICENSE# 52G89-ME T 28"FIRE SETBACK @ RIDGE I / _ o�..�... Abj I _ PROJECT NAME 0 / U-i Ln /�yv U} LL- O �� DDITIONAL ROOF VENTING Q ADDITIONAL ROOF VENTINGo ' _ ``--ACCESS AT GABLE END ACCESS AT GABLE END i'f r N `� �LLJ (S ,r - o ry u W Q 171-611 Uva Q� oma ® \ j � vLEGEND `�� ��� o` � I--- N o EXISTING UTILITY METER ®MAIN SERVICE PANEL NEW PV SUB-PANELS A/C DISCONNECT COMBINER INVERTERS ® GND ELECTRODE rani PV MODULE p 'L� SHEET NAME RACKING RAIL �I�� PLAN O ATTACHMENT POINT � - ' ---RAFTERS �Q n t 4--ROOF PITCH ANGLE SUNRUNMETER __.. OF NEbVy ® VENT DRAWING SCALE � ^O - qa •$ ANO`9 0PLUMSING VENT ®SKY LIGHT �� ^� ^ co - N .T.5. 0 ®CHIMNEY ®COMPOSITE SHINGLES _ SHEET NUMBER GOOD CONDITION aPOTENTIAL SHADING ISSUES -• _ s�0 Oe0935'1 �1� E TRIM/REMOVE A3 NECESSARY _ - OFESSIO -PV-2 r CONSTRUCTION NOTES I .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE DESIGN E DRAFTING BY; MANUFACTURER'S INSTALLATION INSTRUCTIONS, JAMIE MINNICK 2•)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. I NABCEP CERTIFIED 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION, ARRAY#1 051 1 12-129 24 MODULES7 "ii 26°PITCH REVISIONS 66°AZIMUTH i �� III OE9CRIFr1ON DATE REV �, 36" x 36" CLEAR GROUND ACCESS TYP. -_�--�- `I� ORIGINAL 03-12.2010 36" FIRE SETBACK CLEAR PATH 77 of NEW y �o.SClq�yORF CONTRACTOR ELEMENT ENERGY, LLC. 7470 SOUND AVE ( __ _ - —_ _� _ _ _ .7_ I_�T -`I' — ZsFa G60p351 �,�= MATTITUCK, NY 11952 Esslocs�` LICENSE #43889-H LICENSE # 52689-ME II r 28"FIRE SETBACK @ RIDGE e ( _I O II PROJECT NAME LD 2 Lu In m Lu O ADDITIONAL ROOF VENTING Q -" ADDITIONAL ROOF VENTING �� - - _� i - r--� f '—ACCESS AT GABLE END }- ACCESS AT GABLE END—1 ( ) Z LEGEND N D o ®EXISTING UTILITY METER U MAIN SERVICE PANEL o a ry NEW PV SUB-PANELS O ® O A/C DISCONNECT COMBINER INVERTERS SHEET NAME n D 0 f ® GND ELECTRODE or o ^� I aff a PV MODULE ROOF DETAIL mJ ti ti Ov ARRAY#2 aRACKING RAIL 9 MODULE-9] 0 ATTACHMENT POINT 26°PITCH ---RAFTERS 246°AZIMUTH —ROOF PITCH ANGLE DRAWING SCALE CONSTRUCTION SUMMARY 9i SUNRUN METER (�' (33) LG 320N I K-A5 PV MODULES(66.38"X 40'9 ®VENT I V . I-�^ .5. (1)50LAREDGE 5E7600H-U5 INVERTER 0PLUMBING VENT (1)SOLAREDGE 5E3000H-U5 INVERTER ®SKY LIGHT (84)ATTACHMENT POINTS @ 64"OC MAX, ®CHIMNEY SHEET NUMBER (369.2)LF IRONRIDGE XR I X MOUNTING SYSTEM. COMPOSITE SHINGLES \ ROOF TYPE= ASPHALT SHINGLE. E PGOOD CONTION OTENTIAL SHADING ISSUES f V/ —3 TRIM/REMOVE AS NECESSARY LOAD CALCULATIONS ARRAY#I ARRAY#2 odu eel ht ITEM DESCRIPTION ARRAY#I ARRAY#2 of odules 24 9 R Rafter 2x8 D-FIR 16"O.C. 2x I O D-FIR 16"O.G. DE51GN d DRAFTING BY: Total Module Weight 952. 6 Lbs 57.21 Lbs (D) Deckin 1/2"PLYWOOD 112"PLYWOOD JAMIE MINNICK Total Len th of Rail 298 Ft 101.2 F (C) Collar Tie 2x4 -FIR 64"O.C. 2x4 -FIR 64"O,C. NABCEP CERTIFIED Rail Wel ht Per Foot 0.68 Lbs 0.68 Lbs (J) Jo15t 2x8 D-FIR I G"O-C, 2x8 D-FIR @ 16"0.0, 051112-129 Total Rad Weight 182.24 Lbs G8.8 Lb (P) Pitch 6° 26° of S a do oV NEW (RB) Rid a Board/Beam 2x 10 REVISIONS Wel ht per standoff 2 Lbs 2 L 5 Yo (H S an Width 2x 10 yR G.sclq �r 144" 144" DE5CRiPriDN DATE REV Total Standoff Wel ht 120 Lbs 48 Lbs �� OWGINAL os-iz.zois Total Arra Wei ht 1254.8 Lbs 47 Lbs " 9 Point Load 20.9 Lbs 19.7 Lbs Total Arrav Area 443.9 S Ftl 166.4 so Ft Array Dead Load ?.,aI,bs S fftl 2.81_bs S Ft (D) p�OFESStOtsa�'� CONTRACTOR -Asper ASCE 7 -Method 1: i - ( ) ELEMENT ENERGY, LLC. P net = t Pnet3�-2 sec 6,b.7) I =e - 7470 SOUND AVE CLIMACTIC AND Ground Wind Spee Live load, Max fastener (C) MATTITUCK, NY 1 1952 GEOGRAPHIC DESIGN Category Snow Load 3 sec gust pnet30 pe e spacing along LICEN5E# 43889-H CRITERIA Pg mph A5CE7, psrads, 1n. LICENSE # 52689-ME A # 20 130 # 468 S/I 6"x 6"Stainless Steel _ Roof Section 64" B # TYP, TYP, # TYP, Lag Bolts # (N) For SI:1 pound per square foot=0,0479 kPa,1 mile per hour=0.447 m/s. PROJECT NAME a. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural (K) (J) requirements of this code.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as ll lLn determined from Figure R301.2(3),The grade of masonry units shall be determined from ASTM C 34,C 55,C 62,C 73,C 90, U m or C 852. C 129 C 145 C 216 b. The frost line depth may require deeper footings than indicated in Figure R403,1(1).The jurisdiction shall fill In the frost line depth column with F -7, U-JO) the minimum depth of footing below finish grade, C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of localROOF FRAMING DETAIL I� 0 Q subterranean termite damage. d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301,2(4)A).Wind exposure W. W z category shall be determined on a site-specific basis in accordance with Section R301.2.1.4. LU e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the U International Plumbing Code.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience MODULE MOUNTING CLAMP determined by the building official. f f. The jurisdiction shall fill in this part ofthe table with the seismic design category determined from Section R301.2.2,1. SOLAR MODULE U U 9. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and --'" Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a STAINLE55 STEEL 3/8" minimum,special flood hazard areas as identified by the Federal Emergency Management Agency in the Flood Insurance Study for the community, BOLT AND NUT as amended or revised with: Co U 1.The accompanying Flood Insurance Rate Map(FIRM), II.Flood Boundary and Floodway Map(FBFM),and iRONRIDGE ALUMINUM RAIL N Iii,Related supporting data along with any revisions thereto. ALUMINUM"L"BRACKET U The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. h. In accordance with Sections R905.1.2,R905,4.3,1,R905,53.1,R905.6,3.1,R905.7.3,1 and R905,8,3.1,where there has been a history of local damage from the effects of Ice damming,the jurisdiction shall fill in this part of the table with"YES,"Otherwise,the jurisdiction shall fill in this ALUMINUM FLASHING part of the table with"NO," SHEET NAME 1. The jurisdiction shall fill in this part ofthe table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the p 100-year(99 percent)value on the National Climatic Data Centerdata table"Air Freezing Index-USA Method(Base 320F)." 5TRU CTU IRAL J. The jurisdiction shall fill in this part ofthe table with the mean annual temperature from the National Climatic Data Center data table"Air ASPHALT SHINGLE ROOF Freezing Index-USA Method(Base 32"F)." 5/1 G"x G`STAINLE55 k. In accordance with Section R301.2,1.5,where there is local historical data documenting structural damage to buildings due to topographic STEEL LAG BOLT WITH wind speed-up effects,the jurisdiction shall fill in this part of the table with"YES,"Otherwise,the jurisdiction shall indicate"NO"in thispart of the 2 1/2"MIN THREAD table. PENETRATION 5EALED DRAWING SCALE I. In accordance with Figure R301.2(4)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this WITH GEOCEL 45oo F part o the table with"YES"and (EQUIVALENT OR BETTER;) AS NOTED m. In accordance with Section R3011.2,1,2,1,the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. n. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301,2(5)for sites at elevations up to 1000 feet,Sites and elevations above 1000 feet shall have their ground snow load increased from the mapped value by 2 lbs/ft2 for every 100 feet SHEET NUMBER above 1000 feet. ('`) See Figure R301.2(4)B. PV-4 �_ q _ MOUNTING DETAIL I I G�. INVERTER(QTY 2) SOLAREOGE SE7000H-U5,240 VAC PHOTOVOLTAIC ARRAY SUMMARY 99%CEO WEIGM(ED EFFICIENCY TO UTILITY GRID DESIGN DRAFTING BY: NEMA 3R,UL LISTED,INTERNAL GFDI JAMIE MINNICK STRING STRING STRING SUB-ARRAY INV. NABCEP CERTIFIED I.D.# MODULE MODEL LENGTH QTY CITY POWER I.D./� � � I NVERTER I,D.# 051112-129 1.2 PANASONIC VBHN315KA01 12+12 LI L2 N 2 24 7560 W I 3 PANASONIC VBHN315KA01 9 I 9 2835 W 2 G G G hl L2 LI BI-DIRECTIONAL REVISIONSUTILITY METER I I I-PHASE,240 V DESCRIPTION DATE I REV I I l ORIGINAL 103-12-2018 2 LI L2 N N SOLAR LOAD CENTER ( 50 D MOM6121.1 OORB AC DISCONNECT Ll L2 N I 2 • • • 12 1 2 • • •LI 2 I I INTEGRATED j 240 VAC,100 A POINT O INTERCONNECTION I1 DC DISCONNECT I NEMA 3R,UL U5TW 50 DD293NRB PEP,NEC 4021(0XI)t69O,G4(A) I I UL 1741,NEMA 3R 1 (1)40 A 2-POLE DWAr,CR 240 VAC,GOA LENGTH P TAP CONDUCTORS __ --- ---------------- I I {I)20A2-POLE BRCAKER NEMA 3R,UL U5TCD SMALL TEXCEED IO FT _--_-_ _- G ------- I (2)60A FU5E9 STRING I STRING 2 WITH 15 A FUSES j AIN SERVICE DOCONNECT ( I GO "`-'""210 V,200 A 1 I G G L1 .� j SOA Ll LI CONTRACTOR L2 ( I L2 L2 2 hl N�----N _______ _ 1 III --- r G -'" ELEMENT ENERGY, LLC. --_-_ a -----� LI LI L - G G G N 2 1 L---------- G L2 L2 7470 SOUND AVE I ( 20A i MATTITUCK, NY 1 1952 1 Ll 3 Ll Ll LICENSE#43889-H 2 2 L2LICEN5E# 52G89-ME N h! i L2 MAIN SERVICE PANEL L------ -- G ---------------------- OF NLVy 3 )-Pn.3•w I 240 VAC 2 • • • 9 -! 1 INTEGRATED cgC �C 1A �'f- N 200A I I DC DISCONNECT Ll ----_' ( I UL 1741,NEMA SP t5' 9 t G � __ -------------------------- I 2 1 - -� PROJECT NAME STRING 3 j WITH 15 A FUSES N I I -- -. �a ----------- W G G G �--- 1 U SOLAREDGE 5E3000H-U5,240 VAC r Zs�o OG0935''� ,,y62 W EIB7u CEG-WEIGHTED EFFICIENCY AR � NEMA 3R.UL LIST90,INTERNAL GPOI O�ES810NEXISTING GROUNDING LU ELECTROD9 SYSTEM \ WIRE* CONDUIT SCHEDULE LU WCIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND ^/ I'D.# ORIGIN DESTINATION 51ZE PER POLE QUANTITY DERATE INSULATION GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP 1.L (J_J 310.15(5)(3) 51ZE QUANTITY INSULATION (CU/AL) TYPE ESTIMATED Volta e Drop(% un STRING INVERTER AWG# 10 ) SIZE TEMP DERATE DISTANCE 9 p G 0.8 USE-Z/PV Wire AWG#8 I BARE 3)0.15(8)(2a)J(3G) , ` r GU FREE AIR I" 709C O'G5 U �J \J OR EMT 1 10 FT 0.8%a O INVERTER COMBINER PANEL AWG ff G l 6 0.8 THWN-2 - O LS� AWG#6 ! THWN-2 CU COMBINER MAIN PANEL AWG ff G I 3 I THWN-2 PVC: 1° 45QC 0.87 25 FT O.G% AWG#8 I THWN-2 CU PVC I" 45eC 0.87 115 FT O.G% d N U ELECTRICAL NOTES I.)ALL EQUIPMENT TO BE L15TED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. SHEET NAME 2,)ALL CONDUCTORS SHALL BE COPPER,RATED FOR GOO V AND 900C WET ENVIRONMENT. CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY #I PV Source Circuit Wire Ampacity Calculation 2 TO,AND LOCATED AS CLOSE A5 POSSIBLE TO THE NEAREST RIDGE, HIP,OR VALLEY, [NEC G90.8(B)(1)]: (150•(#of 5trings)•(I,5G)= 10.8 A -LINE DIA. 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL AWG#10,ampacity•Temp Derate'Conduit Pill Derate-20.8 A CONFIGURATION 3 COMPLY WITH NEC 110,2G. 20.8 A> 10,8 A, therefore DC wire size jr,valid. Modules per 5trin 12.E-12 s 9 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS,CONTRACTOR SHALL #2 Inverter Output Wire Ampaclty Calculation Strings per Inverter 2 It I FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTING5 AND ACE55ORIE5 TO FULFILL Number of Inverters APPLICABLE CODES AND 5TANDARD5• Inverter Output Circuit OCP Calculation(Inverter Imp)•(I.25) =39.56 A 2 G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, AWG#G,derated ampacity(Temp Deratc)°(Conduit Fill Derate)0 52,2 A Record low temp I ORC DRAWING SCALE THE CONTRACTOR SHALL 51ZE THEM ACCORDINGLY. 52.2 A>35,58 A,therefore AC Wire size 15 valid. Voc Temp Coefficiento 7,)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY V151BLE. 0,I G ioJgC 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE #3 Combined Ampacity Calculation DC SYSTEM SPECIFICATIONS CALCULATIONS N-T-5. SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION, Combined Inverter OutputPCircuit Calculation(Inverter Im 1.25 0 eratin Current 10.8 A =(#of strip s°im 9,)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG )`( ) =55.21 A Operating Volta e OR ILSCO GBL-4DBT LAY-IN WG, 350 V =#modules In series• m AWG#G,ampaaty(femp Derate)°(Conduit pill Derate)=65.25 A Max.System Voltage 5C0 V =(#modules in series° w 10.)THE POLARITY OF THE GROUNDED CONDUCTORS IS(positivefneVtiva) G5 25 A> 55,21 A.therefore AC wire size ID va11d. )[(((-#'##.oV/UC•,01)°(LO Temp##QC-25))°(Voc))+(Voc)] OR Short Circuit Current 15 A =(#of strip s)•(Isc)'(1.25)per Art.G90.6(A)(1) SHEET NUMBER 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35 AC SYSTEM SPECIFICATIONS (�,�// Max AC Out ut Current 55.2 1 A f -'5 O eratln AC Volta 240 V