HomeMy WebLinkAbout42610-Z gUFFI?t/�c Town of Southold
o�A o� 5/31/2018
P.O.Box 1179
0
t 53095 Main Rd
�yfj0�
W, Southold,New York 11971
CERTIFICATE OF, OCCUPANCY
No: 39673 Date: 5/31/2018
THIS CERTIFIES that the building GENERATOR
Location of Property: 11985 Soundview Ave, Southold
SCTM#: 473889 Sec/Block/Lot: 54.-5-46.2
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
4/11/2018 pursuant to which Building Permit No. 42610 dated 4/26/2018
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
ACCESSORY GENERATOR AS APPLIED FOR
The certificate is issued to Boltz,William&Erhardt,William
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 42610 05-25-2018
PLUMBERS CERTIFICATION DATED
Authorized Signature
So�Futx, TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
Py_• o� SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 42610 Date: 4/26/2018
Permission is hereby granted to:
Boltz, William & Erhardt, William
345 E 56th St Apt 15F
New York, NY 10022
To: install generator as applied for.
At premises located at:
11985 Soundview Ave, Southold
SCTM # 473889
Sec/Block/Lot# 54.-5-46.2
Pursuant to application dated 4/11/2018 and approved by the Building Inspector.
To expire on 10/26/2019.
Fees:
ACCESSORY $100.00
ELECTRIC $85.00
CO -RESIDENTIAL $50.00
Total: $235.00
41/
B i i pector
Form No.6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead.
5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval'of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied,the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00, Alterations to dwelling$50.00,
Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building- $100.00
3. Copy of Certificate of Occupancy - $.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00
Date.
New Construction: Old or Pre-existing Building: (check one)
Location of Property: l ��� cs11ug1ja&4)
House No. ,Str/eet Hamlet
Owner or Owners of Property: e J 1l i--"r-hard-4-
Suffolk County Tax Map No 1000, Section 5 f Blockrj Lot
Subdivision Filed Map. Lot:
Permit No. Date of Permit. Applicant:
Health Dept. Approval: Underwriters Approval:
Planning Board Approval: /
Request for: Temporary Certificate Final Certificate: l✓ (check one)
Fee Submitted: $ �j U
A), A
Applicant Signature
h®��ypF SOUj�®!
Town Hall Annex Telephone(631)765-1802
54375 Main Road CAR -44C Fax(631)765-9502
P.O.Box 1179 roger.richert(aD-town.southold.ny.us
Southold,NY 11971-0959
(►JTZ, �C."
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICIAL COMPLIANCE
SITE LOCATION
Issued To: Erhardt (Boltz)
Address: 11985 Soundview Avenue city,Southold st: New York zip: 11971
Building Permit#: 42610 Section: 54 Block. 5 Lot: 46.2
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: DBA: L.I. Emergency Power License No: 3994-ME
SITE DETAILS
Office Use Only
Residential X Indoor X Basement Service Only
Commerical Outdoor X 1st Floor Pool
New Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
INVENTORY
Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures
Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors
Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps
Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks
Disconnect Switches Twist Lock Exit Fixtures TVSS
Other Equipment. 11 KW Standby Generator with 100A Transfer.
Notes:
Inspector Signature: - Date: May 25, 2018
0-Cert Electrical Compliance Form.xls
Of SOUTyOIo
# TOWN OF SOUTHOLD BUILDING DEPT.
IOU 765-1802
INSPECTION ,
�z�l
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
[ ] CODE VIOLATION -[ �] CAULKING
REMARKS:
-L d �C
DATE 4i 19 INSPECTOR
FIELD INSPECTION REPORT DATE COMMENTS
FOUNDATION (1ST)
-------------------------------------
'FOUNDATION (2ND)
z
ROUGH FRAMING& t�
PLUMBING y CTS
' e
INSULATION PER N.Y-.
STATE ENERGY CODE �•�
FINAL
ADDITIONAL COMMENTS
Cy
� Z
btdik
T ��
t
� z
b
H
TOWN 1�S�OF -SiOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST
BUIL-T�ING DEPARTMENT Do you have or need the following,before applying?
TOWN HALL Board of Health
SOUTHOLD,NY 11971 4 sets of Building Plans
TEL: (631) 765-1802 Planning Board approval
FAX: (631) 765-9502 C� Survey
Southoldtownny.gov PERMIT NO. U Check
Septic Form
N.Y.S.D.E.C.
Trustees
C.O.Application
Flood Permit
Examined ,20J Single&Separate
Truss Identification Form
Storm-Water Assessment Form
Contact:
Approved ,20 Mail to:
Disapproved a/c
Phone:
Expiration rao
DBuilc'ffiWspector
APR 200 �
APPLICATION FOR BUILDING PERMIT
BUMDING DE"' Date , 20
TOWN OF SO�OLD INSTRUCTIONS
CO
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections..
Om m A.
WNature f applicant or name,if a corporation)
ww
SAbIliald e IA-/ 11??
(Mailing address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder
6lZAVK7
Name of owner of premises
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No.
Plumbers License No.
Electricians License No. 39 - — 7JLU P}S �& Cd-t Wat&,ew"oen,�W1 Awe!?t^
Other Trade's License No.
1. Location of land on which proposed work will be done:
House Number Street Hamlet
County Tax Map No. 1000 Section Block Lot qG , )-
Sub ivisic-n Filed Map No. Lot
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy &i
b. Intended use and occupancy /geZI CCS
3. Nature of work(check which applicable):New Building Addition Alteration
Repair Removal Demolition Other Work
Wp (Description)
4. Estimated Cost � /o, �35� 0� Fee
(To be paid on filing this application)
5. If dwelling, number of dwelling units Number of dwelling units on each floor
If garage, number of cars
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. Dimensions of existing structures, if any: Front Rear Depth
Height Number of Stories
Dimensions of same structure with alterations or additions: Front Rear
Depth' Height Number of Stories
8. Dimensions of entire new construction: Front Rear Depth
Height Number of Stories
9. Size of lot: Front Rear Depth
10. Date of Purchase Name of Former Owner
11. Zone or use district in which premises are situated
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO
13. Will lot be re-graded? YES NO V Will excess fill be removed from premises? YES NO
//98S s ";1OW ce.
14. Names of Owner of premises Bill 9r674&Y-Address JAff %P1d# Phone No.h31—J'7S'31`7
Name of Architect Address Phone No
Name of Contractor Address Phone No.
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO
* IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES NO
* IF YES, PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUNTY%F�ti _
to Aaa being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signing contract) above named,
(S)He is the
(Contractor,Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
Sw r n to before me this N MED►NA
day of AR _STATE OF NEW YORK
No of ME6242175
WkA�L Q.-iciatied in Suffolk coun0 i,,, A
Notary Public My Commission Expires May 31. 2019 Signature of Applicant
u -�• ti
S;�1FfrOt ;.` BUILDING DEPARTMENT- Electrical Inspector
TOWN OF SOUTHOLD
cc '' Town Hall Annex - 54375 Main Road - PO Box 1179
oy° • o� Southold, New York 11971-0959
Telephone (631) 765-1802 - FAX (631) 765-9502
ro er:richert0 :town.soufhold.ny.us
APPLICATION FOR ELECTRICAL INSPECTION
REQUESTED BY: �')CfGG2� �Ul _ _ _ Dater
Company Name: - --= f dQ
Name: --
License No.: q (�_- ,(,� _ email: I&A Q _-_. �,rf2/•
Address: ---
Phone No::
I —
JOB SITE INFORMATION: (All Information Required)
Name: PwZI_ harms- __
Address: l JE--:5 Sauna _ -VU,2 w -
Cross Street:
Phone No.: -
BIdg.Permit#: - 471(o 0 __ ` T email: " - -
i Tax Map District: 1000 Section: Block;_
BRIEF DESCRIPTION OF WORK (Please Print Clearly)
<« awl AF auj aa- t ix -ate
Circle All That Apply:
Is job ready for inspection?: YES / NO Rough In Final
Do you need a Temp Certificate?: YES / NO Issued On
Temp Information: (All information required)
Service Size .1 Ph 3 Ph Size: _ -_--- - A # Meters -_ Old Meter#
New Service - Fire Reconnect- Flood Reconnect- Service Reconnected - Underground - Overhead
#-Underground Laterals 1 2 H Frame Pole Work done on Service?._- Y
Additional Information: -
-- - - - - .PAYMENT DUE-WITH APPLICATION
82-Request for Inspection FormAs
w i
CONSENT TO INSPECTION
A the undersigned, do(es) hereby state:rl2a�
Owner(s)Name(s)
That the undersigned(is) (are) the owner(s) of the premises in the wn of
s
Southold, located at Mpe S'dl/Y1 1Ct�J mow. �k�cd1To ,
which is shown and designated on the Suffolk County Tax Map as District 1000,
Section , Block , Lot
That the undersigned (has) (have) filed, or cause to be filed,,an application in the
Southold Town Building Inspector's Office for he following: hy
That the undersigned do(es) hereby give consent to the Building Inspectors of the
Town of Southold to enter upon the above described property, including any and all
buildings located thereon, to conduct such inspections as they may deem necessary with
respect to the aforesaid application, including inspections to determine that said premises
comply with all of the laws, ordinances, rules and regulations of the Town of Southold.
The undersigned, in consenting to such inspections, do(es) so with the knowledge
and understanding that any information obtained in the conduct of such inspections may
be used in subsequent prosecutions for violations of the laws, ordinances, rules or
regulations of the Town of Southold.
Dated: -3 -3l -/S' Q.—
(Signature)
I.J r I a v►� A. Er ,cJ 4
(Print Name)
(Signature
i I o.m,. —D. /+,i--
(Print Name)
Bunch, Connie
From: Kelly Jones-Carall <kelly@long islandemergencypower.com>
Sent: Thursday, April 26, 2018 9:17 AM
To: Bunch, Connie
Subject: Re: MARKED SURVEY
Connie
Please mail it to us.
Our address is:
I
2 Ocean Avenue
Deer park,NY 11729
Thank you.
Yours,
Kelly Jones-Carall
Customer Service Specialist
Long Island Emergency Power
2 Ocean Avenue
Deer Park, NY 11729
Phone: 631-586-7513 x106
Fax: 631-595-1565
EMERGENCY CALLS: 631-586-7513 AND FOLLOW PROMPTS FOR EMERGENCIES
Exclusive Generac Elite PowerPro Dealer &
Generac's 2012 Aftermarket Sales and Service Award Winner!
As featured in The Wall Street Journal article, "A Sales Surge for Generator Maker", November 7, 2012
On Thu, Apr 26, 2018 at 9:15 AM, Bunch, Connie <Connie.Bunchgtown.southold.n�us>wrote:
Thank you. Do you want to pick up the permit or have us mail it to you?
Connie
From: Kelly Jones-Carall [mailto:keIIV@longislandemergencypower.com]
Sent:Thursday,April 26, 2018 9:11 AM
To: Bunch, Connie<Connie.Bunch @town.southold.nv.us>
Cc:Joann Medina <ioann@lonBislandemergencypower.com>
Subject: MARKED SURVEY
i
Connie,
Please find attached a copy of the survey showing the location of the generator. If you need anything further
please let me know.
Thank you.
Yours,
Kelly Jones-Carall
Customer Service Specialist
Long Island Emergency Power
2 Ocean Avenue
Deer Park, NY 11729
Phone: 631-586-7513 x106
Fax: 631-595-1565
EMERGENCY CALLS: 631-586-7513 AND FOLLOW PROMPTS FOR EMERGENCIES
Exclusive Generac Elite PowerPro Dealer &
Generac's 2012 Aftermarket Sales and Service Award Winner!
As featured in The Wall Street Journal article, "A Sales Surge for Generator Maker", November 7, 2012
2
\ t-iYATT AND ALE3E'R7SON
- r
f�.3.
' MON. 4'L.� •� •—" �- .� �-
lLA"O N/F
OF t
I MOLlSIADES ,
�r,rofv_
O
k
V ilk 3� ICE
P7PE
0 3sa•.4 \J i ay
,• t � 7-S• V I
_w 73
PfPE' o I'rasea
I �
LAN OF �F � a" � 9 7.3` .�.► c_tr � fueANOS =(� �
CAPELLI
LTO � _ _
� ao wx
C01/ERED ra �_� M
W N 40 � STOOP ti C.�l710E W
f g1'ONE NEM! � _3
y,• a�
, x �
M N_ i =ys.(}O MON.
42-a1•00-'W
��-� EDGE OF PAVEMENT
S i�►�.TND�TI�W A'VENi3E
THE WA TE'R SUPPL Y. MIL-LLS ANO CESSPOOL
L OCA 770NS SHO KW ARE FROM F/EL 0 4CAL3SER SIA T/ONS
ANL? OR t7A TA 08 TA/NEO FRpM OTHERS.
AREA: 4 ,503.57 Sq.FT. or _C1T ACRES ELEVAT/ON 4;),4 7"U".
UNA U THORf ZE0 AL TERA TION OR AOOf TION TO TN/S SURVEY JS A KOLA T/ON OF SECTIDN 7209 OF THL;- NEL✓ YORK STA TE EOU�CA TION L AW GQPIES OF TH/S SUR VEY
MAO NOT BEAR/NG y'HE' LANG SURV£YOR S E'MB05SE0' SEAL SHALL NOT SE CONS/OEREl7 TO 8E A V gLIO TRUE GOP Y. GUARAN TEES fNOICA TEO ItIE'REON SHALL RUN
ONLY TO 77dE PERSON FOR WHOM 'lHE SURVt Y 1S PREl-AREL7 ANO ON H/S BEHALF TO THE T/7L& COMPANY GC7VLRNMENTAL AGENCY ANO LENIJlNG /N577TUT1ON
L157-EO HEREON, ANO T+O THE ASSIG/VEES CF THE LENQING IMSTITLf TION GUARANTEES .ARE NOT TRANSFERABLE_
THE OFFSETS CNK? p/ME/VSIONS SHOWIV HEREON FROM THE ARpPERTY LIMES TO THE STRUCTURES Al?-- FOR A SPECIFIC PURPOSE ANO USE THEREFORE THEY ARE
NQT lNTEiVOEO TO MpNUMENT TldE PROPERTY LINES OR TC GUIDE 77-fE' ERECTION OF FENCES A00/T/ONAG STRUCTURES OR ANO OTHER /M'PR01/L�'ME'N TS. FASta+tiIEN TS
ANOfPR SflBSURFi4 CE' S 774UCFLJRES / EC`OROEO OR UNRECdROEO ARE NOT GUARAN TEELa UNLESS PH YS/CALL Y E VIfJEN T OIV 7-"E' PREM/SES .4-r THE TIM£ OF SLIR VE Y
SUFFOLK COUNTY DEPT OF LABOR,LICENSING&CONSUMER AFFAIRS
MASTER
ELECTRICIAN
NAME
r
MICHAEL S TOWERS
3 This certifies that the BUSNESS NAME
1 TOWERS ELECTRICAL CONTRACTING INC
! bearer is duly DBA
licensed by the
County of Suffolk U0��0aNumber Dazeiss�sa
r7 3994-ME 04/01/1990
+jt2lCR%l2l�L.ff•
Commlssbnar "PRAnON DATE 0410112018
SUFFOLK COUNTY DEPT OF LABOR,
{ ` I
LICENSING 3 CONSUMER AFFAIR_S
HOMEIMPROVEMENT
CONTRACTOR
LICENSE
MICHAEL S TOWERS
This eettifes that the BUSNMNAME
bearer IS duly TOWERS ELECTRICAL CONTRACTING INC
DBA
licensed`bythe Lker$eNumbrr o�ol_Surtl
County of Suffolk
3'8334-H 09/13/2005'
C—s:bner ExPRAnav DATE 09/01/2019
A
AP ROVED AS NOTED RETAIN STORM WAT
4 -L�
ER RUNOFF
DATE.4#4 B1
.P.# D OF�SUANT TO CHAPTER 236
FEE:._ - d BY: HE TOWN CODE,
-NOTIFY,BUILDING DEPARTMENT AT
'765-1802 SAM TO 4 PM FOR THE
FOLLdWING INSPECTIONS:
1;: ,fOUNDATioN - TWO REQUIRED
;FOR POURED CONCRETE ELECTRICAL2'ROUGH.=-FRAMING & PLUMBING INSPECTION REQUIRE®
3. INSULATION
A'FINAL'-'CONSTRUCTION MUST
BE COMPLETE FOR C.O.
-ALL CONSTRUCTION SHALL MEET THE
REOUTAEINENTS OF THE CODES OF NEW
YORK STATE. NOT RESPONSIBLE FOR
DESIGN OR CONSTRUCTION ERRORS.
COMPLY WITH ALL CODES OF
NEW YORK STATE & TOWN CODES
AS REQUIRED AND CONDITIONS OF
ES
�iimS.BEG
OCCUPANCY O
USE IS UNLAWFUL
WITHOUT CERTIFIGAT
OF OCCUPANCY
GENERAC�
GUARDIAN° SERIES
Residential Standby Generators
Air-Cooled Gas Engine
NEW-
INCLUDES:
True Power Electrical Technology Standby Power Rating
Models G007029-0,G007030-0 (Aluminum-Bisque) -9 kW 60 Hz
• Two Line LCD Multilingual Digital Models G007032-0, G007033-0 (Aluminum-Bisque)- 11 kW 60 Hz
Evolution TM Controller(English/Spanish/ Model G007031-0(Aluminum-Bisque) 11 kW 60 Hz
French/Portuguese)
• Two Transfer Switch Options Available:
100 Amp 16 Circuit Switch or
200 Amp Service Rated Switch.
See Page 4 for Details.
3
• Electronic Governor = r`
• System Status&Maintenance Interval LED Indicators
• Sound Attenuated Enclosure --
- GENERAC' _
• Flexible Fuel Line Connector
® Direct-To-Dirt Composite Mounting Pad
• Natural Gas or LP Gas Operation C uL uS
• 5 Year Limited Warranty LISTED
Capability to be installed within 18" 457 mm
Note,CUL certification only applies to unbundled units and units packaged with
• Ca
p ( ) limited circuit switches Units packaged with the Smart Switch are UL certified in
of a building* the USA only
*Only if located away from doors,windows and fresh air intakes,and unless
otherwise directed by local codes
FEATURES
O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Generac's O SOLID-STATE,FREQUENCY COMPENSATED VOLTAGE REGULATION:
success in providing the most reliable generators possible.Generac's G-Force engine This state-of-the-art power maximizing regulation system is standard on
lineup offers added peace of mind and reliability for when you need it the most The all Generac models It provides optimized FAST RESPONSE to changing
G-Force series engines are purpose built and designed to handle the rigors of load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
extended run times in high temperatures and extreme operating conditions. electronically torque-matching the surge loads to the engine. Digital
voltage regulation at±1%.
O TRUE POWER- ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer
form produce less than 5%Total Harmonic Distortion for utility quality power.This allows network provides parts and service know-how for the entire unit,from the
confident operation of sensitive electronic equipment and micro-chip based appliances, engine to the smallest electronic component.
such as variable speed HVAC systems.
O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are
✓ PROTOTYPE TESTED J NEMA l i-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this
J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility
w GENE R AC tiat7°ass '�y4�,�
I— PROMISE °
c� pe � Link
+Bulli/n Ne USA usIRq OamesOc and Iorelgn paNs
GENERAC®
9/11 kW features and benefits
Engine
• Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinderwalls and plasma moly rings helps the engine
run cooler,reducing oil consumption resulting in longer engine life.
• "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life.
• Electronic ignition/spark advance These features combine to assure smooth,quick starting every time.
• Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life.Now featur-
ing up to a 2 year/200 hour oil change interval.
• Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil.
• High temperature shutdown Prevents damage due to overheating.
Generator
• Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator.
• Skewed stator Produces a smooth output waveform for compatibility with electronic equipment.
• Displaced phase excitation Maximizes motor starting capability
• Automatic voltage regulation Regulates the output voltage to±1%prevents damaging voltage spikes.
• UL 2200 listed For your safety
Transfer Switch (if applicable)
• Fully automatic Transfers your vital electrical loads to the energized source of power.
• NEMA 3R Can be installed inside or outside for maximum flexibility.
• Remote mounting Mounts near your existing distribution panel for simple,low-cost installation.
Evolution"" Controls
• Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition.
• Two-line LCD multilingual display Provides homeowners easily visible logs of history,maintenance and events up to 50 occurrences.
• Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations.
• Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage.
• Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
• Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 12 seconds by a
qualified dealer.
• Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds
• Engine cool-down Allows engine to cool priorto shutdown,setpoint approximately 1 minute.
• Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 12 minutes every
other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel
costs to the owner.
• Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM-style batteries.
• Main line circuit breaker Protects generator from overload.
• Electronic governor Maintains constant 60 Hz frequency.
Unit
• SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150
mph.Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostat-
ically applied textured epoxy paint for added durability,
• Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries
• Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18"away from a building.
Installation System
• 1 it(305 mm)flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe.
• Direct-to-dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system
0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine,prolonging engine life.
r
GENE AC"
9/11 kW specifications
Generator
Model G007029-0,G007030-0(9 kW) G007031-0,G007032-0,G907033-0(11 kW)
Rated Maximum Continuous Power Capacity(LP) 9,000 Watts' 11,000 Watts`,
Rated Maximum Continuous Power Capacity(NG) 8,000 Watts" 10,000 Watts'
Rated Voltage 240 240
Rated Maximum Continuous Load Current—240 Volts(LP/NG) 37.5/33.3 458141.7
Total Harmonic Distortion Less than 5% Less than 5_%
Main Line Circuit Breaker 40 Amp 50 Amp r
Phase 1 1
Number of Rotor Poles 2 2
Rated AC Frequency 60 Hz 60 Hz
Power Factor 1.0 10
Battery Requirement(not ineluded) 12 Volts,Group 26R_640 CCA Minimum or Group 35AGM 650 CCA Minimum
Unit Weight(Ib/kg) 340/154 348/158
Dimensions(L x W x H)in%mm 48 x 25 x 29/1218 x 638 x 732
Sound output in dB(A)at 23 R(7 m)with generator operating at normal load" 66 63
Engine
Type of Engine GENERAC G-Force 400 Series GENERAL G-Force 500 Series
Number of Cylinders 1 2
Displacement 426 cc 530 cc
Cylinder Black Aluminum w/Cast Iron Sleeve Aluminum w/Cast Iron Sleeve
Valve Arrangement Overhead Valve Overhead Valve
Ignition System Solid-state Q Magneto Solid-state w/Magneto
Governor System Electronic. Electronic
Compression Ratio 9.0.1 951
Starter 12 Vdc 12 Vdc
Oil Capacity Including Filter Approx 1.1 gV1.0 L Approx.1 7 gV1.6 L
Operating rpm 3,600 3,600
Fuel Consumption
Natural Gas ft3/hr(m3/hr)
1/2 Load 90(2.55) 107(3 03)
Full Load 120(3 4) 159(4.50)
Liquid Propane ft3/hr(gal/hr)(1/hr]
1/2 Load 31.6(.87)[3.29] 44.4(1.22)[4.621
Full Load 50(1 37)[5.2] 71.6(1:97)[7.45]
Note Fuel pipe must be sized for full load.Required fuel,ppressure to generator fuel inlet at all load ranges-3.5-7"water column(7-13 mm mercury)for natural gas,10-121 water column(19-22 mm mercury)
for LP gas For Btu content,multiply ft3/hr x 2500(LP)or ft'/hr x 1000(NG) For Megajoule content,multiply m3/hr x 9315(LP)or m3/hr x 37 26(NG)
Controls
2-1-ine Plain Text Multilingual LCD Display Simple user interface for ease of operation
Mode Bettons-Auto Automatic Start on Utility failure 7 day exerciser
Manual Start with starter control,unit stays on If utility fails,transfer to(cad takes place
Oft Stops unit.Power is removed Control and charger still operate
Ready to Run/Maintenance Messages Standard
Engine Run Hours Indication Standard
Programmable start delay between 2-1500 seconds Standard(programmable by dealer only)
Util(tyV_oltajje Loss/Retum to Utility Adjustable(9rownoutSetting) From 140_-171 V/190-216 V
Future Set Capable Exerciser/Exercise Set Error Warning Standard
Run/Alarm/Maintenance Logs 50 Events Each
Engine Start Sequence Cyclic cranking Engine cranks a maximum of five times at factory set intervals and durations.
Starter Lock-out Starter cannot re-engage until 5 sec after engine has stopped
Smart Battery Charger Standard
Charger Faull/Missing AC Warning Standard
Low Battery/Battery ProblemProtection and Battery Condition Indication Standard
Automatic Voltage Regulation with Over and Under Voltage Protection Standard
Under-Frequency/Overload/Stepper Overcurrent Protection Standard
Safety Fused/Fuse Problem Protection Standard
Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard
Overcrank/Overspeed(@ 72 Hz)%rpm Sense Loss Shutdown Standard
High Engine Temperature Shutdown Standard
Internal FaullAncorrectWiring Proiection Standard
Common External Fault Capability Standard
Field Upgradable firmware Standard
"Sound levels are taken from the front of the generator Sound levels taken from other sides of the generator maybe higher depending on installation parameters Rating definitions-Standby Applicable for supplying emergency power for the durabon
of the utility power outage No overload capability is available for this rating (All ratings in accordance with BS5514,IS03046 and DIN6271) 'Maximum kilovolt amps and current are subject to and limited by such factors as fuel Btu/megajoule
content,ambient temperature,altitude,engine powerand condition,etc Maximum power decreases about 3 5 percentfor each 1,000 feet(304 8 meters)above sea level,and also will decrease about 1 percentfor each 6*G(10'F)above 16T(60°F)
GENERAC®
9/11 kW switch options
Limited Circuits Switch Features Model G007030-0(9kW) G007032-0(11 kW)
16 circuits,breakers not included. No of Poles ? 2
• Current Rating(Amps) 100 100
• Rated for all classes of load,100%equipment rated,both inductive and Voitage Rating(VAC) 120/240,18 120%240,"16
resistive. Utility Voltage Monitor(Fixed)'
0 2 pole,250 VAC cOntaGtOrS. -Pick-up 80% 80%
-Dropout 65% 65%
r • 30 millisecond transfer time. Retum to Utility` approx.15 sec approx.15 sec
Single Coil design. Exercises bi-weekly for 12 minutes*t Standard Standard
Main contacts are silver plated or silver alloy to resist welding and sticking. 'UL Listed Standard standard
Total circuits Available 16 16
NEMA/UL 3R aluminum outdoor enclosure. nd
• Tandem Breaker Capabilities 8 Tandnd ems B Tandems
Multi listed for use with 1"standard,tandem,GFCI and AFCI breakers Circuit Breaker Protected
from Siemens,Murray,Eaton and Square D for the most flexible and cost Available RMS Symmetrical 10,000 10,000
effective install. Fault current @ 250 volts
*Function of Evolution Controller
Dimensions t Can be set to weekly or monthly
W1
Height Width
H1 H2 W1 W2 Depth
in 26.75 301 10.5 13.5 6.91
mm 679.4 764.3 266.7 343 0 175.4
H2 H1
Wire Ranges
Conductor Lug Neutral Lug I Ground Lug
1/0-#14 2/0-#14 2/0-#14 W2
Service Rated Smart Switch Features Model G007933-0(11kW)
available on 11 kW model only No of Poles 2_
Includes Digital Power Management Technology standard(DPM). Current Rating(Amps) 200
Voltage'Rating(VAC) 120/240,1.8_
® Intelligently manages up to four air conditioner loads with no additional Utility Voltage Monitor(Fixed)*
hardware. -Pickup 80%
-Dropout 65%
• Up to eight more large(240 VAC)loads can be managed when used in Return to Utility' approx 13 sac
conjunction with Smart Management Modules(SMMs). Exercises bi-weekly for 12 minutes*t Standard
Electrically operated,mechanically-held contacts for fast,clean connec- -UL Listed _ standard
tions. Enclosure Type NEMA/UL 3R
Rated for all classes of load,100%equipment rated,both inductive and Circuit Breaker Protected 22,000
resistive. Lug Range 250 MCM-#6
• Service equipment rated,dual coil design. *Function of Evolution Controller
Rated for both aluminum and copper conductors. t Can be set to weekly or monthly
Main contacts are silver plated or silver alloy to resist welding and sticking. w,
NEMA/UL 3R aluminum outdoor enclosure.
Dimensions
200 Amps 120/240,1e H2 Hi
Open Transition Service Rated
Height Width
H1 H2 Wi W2 Depth
in 26.75 301 105 13.5 691
mm 679.4 764.3 2667 3430 175.4 oEarH --w2 I
{� Section 3: Site Selection and Preparation
Section 3: Site Selection and Preparation
Se �
Site Selection
No operable windows or openings in the wall permitted � Existing Wall
within 1.52 m(5 ft)from any point of the generator.
' 5 it 18 in(457 mm) 5 it
(1.62 m)� MinimumDistance (1.52 m)
i
3 it(0.91 m)—. Top of Generator . 3 ft(0.91 m)
These guidelines are based upon fire testing of
Allow sufficient room on all sides of the the generator enclosure and the manufacturer's
generator.for maintenance and servicing. requirement for air flow for proper operation.
Clearance from the ends and front of the 3 It(0.91 m) Local codes may be different and more restrictive
generator must be 3'ft m (0.91).This includes than what is described here.
shrubs, bushes and trees. Clearance from the
back of the generator must be a minimum of 18
in(457 mm).-Clearance at the top should be a NOTE: Removable fence panels for servicing
minimum of 5 ft (1.52 m) from any structure, cannot be placed less than 457 mm (18 in) in
overhang or projections from the wall. front of the generator.
DO NOT install under wooden decks or
structures unless there is at least 5 ft(1.52 m)
of clearance above the generator. — — — ` _
— 5 (152 m)
Minimum Distance
1
5ft(1.52m)
Minimum Distance
Clearance from operable windows,
doors or any openings in the wall.
000607
Figure 3-1. Installation Guidelines
Install the generator set, in its protective enclosure, • Install the generator on high ground where water
outdoors, where adequate cooling and ventilating air is levels will not rise and endanger it. It should not
always available(Figure 3-1). Consider these factors: operate in or be subjected to standing water.
• The installation of the generator must comply • Allow sufficient room on all sides of the generator
strictly with NFPA 37, NFPA 54, NFPA 58 and for maintenance and servicing. This unit must be
NFPA 70 standards. installed in accordance with any codes that are in
• Install the unit where air inlet and outlet openings place in your country or local jurisdiction for
will not become obstructed by leaves, grass, snow, minimum distances from other structures.
etc. If prevailing winds will cause blowing or • Clearance from the ends and front of the generator
drifting, consider using a windbreak-to protect the must be 3 ft(0.91 m). This includes shrubs, bushes
-unit. and trees. Clearance 'from the back of the
generator must be a minimum of 18 in (457 mm).
Installation Guidelines For 60 Hz Air-cooled Generators 11
Section 3: Site Selection and Preparation
Clearance at the top-should be a minimum of 5 ft 2. The weatherproof enclosure is constructed of no
(1.52 m) from any structure, overhang or combustible materials and it has been demo
projections from the wall. strated that afire within the enclosure will not ignite
• DO NOT install under wooden decks or structures combustible materials outside the enclosure.
unless there is at least 5 ft (1.52 m) of clearance Annex A ' Explanatory Material
above the generator.
• Install the unit where rain gutter down spouts, roof A4.1.4 (2) Means of demonstrating compliance are by
run-off, landscape irrigation, water sprinklers or means of full scale fire test or by calculation procedures.
sump pump discharge does not flood the unit or Because of the limited spaces that are frequently
spray the enclosure, including any air inlet or outlet available for installation, it has become apparent that
openings. exception (2) would be beneficial for many residential
• Install the unit where services will not be affected and commercial installations. With that in mind, the
or obstructed, including concealed, underground or manufacturer contracted with an independent testing
covered services such as electrical,fuel, phone, air laboratory to run full scale fire tests to assure that the
conditioning or irrigation. This could affect enclosure will not ignite combustible materials outside
Warranty Coverage. the enclosure.
• Where strong prevailing winds blow from one NOTE: Southwest Research Institute testing approves
direction, face the generator air inlet openings to 18 in (457 mm) installation minimum from structure.
the prevailing winds. Southwest Research is a nationally recognized third
• Install the generator as close as possible to the fuel
party testing and listing agency.
supply to reduce the length of piping. REMEMBER The criteria was to determine the worst case fire scenario
THAT LAWS OR CODES MAY REGULATE THE within the generator and to determine the ignitability-of
DISTANCE AND LOCATION. In the absence of items outside the engine enclosure at various distances.
local codes regarding placement or clearance, we The enclosure is constructed of non-combustible
recommend following these guidelines. materials, and the results and conclusions from the
• Install the generator as close as possible to the independent testing lab indicated that any fire within the
transfer switch. REMEMBER THAT LAWS OR generator enclosure would not pose any ignition risk to
CODES MAY REGULATE THE DISTANCE AND nearby combustibles or structures, with or without fire
LOCATION. service personnel response.
• The generator must be installed on a level surface.
The generator must be level within a 0.5 in (13
mm)all around. S
n„w„ R 0
• The generator is typically placed on pea gravel,
crushed stone or a concrete pad. Check local
codes to see what type is required. If a concrete sa,�„ee
pad is required, all applicable codes should be SAMS
seo Antonb. Texas
followed. SwRI io No. 93204-09-09
Installation Guidelines for Stationary Air-Cooled Stationary Engine Generator Assembly
Generators MODEL NUMBER TBA
Manufactured By
The National Fire Protection Association has a standard °a�eO war SYV� �•
IMHte•eter• EYI
for the installation and use of'stationary combustion
engines. That standard is NFPA 37, its requirements limit Compliant with Clause (21
the spacing of an enclosed generator set from a structure of section 4.9.4 of NF-PA 37
or wall (Figure 3-1).
NFPA 37, Section 4.1.4, Engines Located Outdoors: 000sos
Engines, and their weatherproof housings if provided, Figure 3-2. Southwest Research Institute Decal
that are installed outdoors shall be located at least.5 ft
(1.52 m)from openings in walls and at least 5 ft(1.52 m) Southwest Research Institute Decal (located inside the
from structures having combustible walls. A minimum generator, next to the generator's data decal)
separation shall not be required where the following http.lAvww.swri.org/4org/d01/fire/listlab/listprod/directorhtm
conditions exist:
Based on this testing and the requirements of NFPA 37,
i. The adjacent wall of the structure has a fire resis- Sec 4.1.4,the guidelines for installation of the generators
tante rating of at least 1 hour. listed above are changed to 18 in (457 mm) from the
12 Installation Guidelines For 60 Hz Air-cooled Generators
Section 3: Site Selection and Preparation
R
:;• ack side of the generator to a stationary wall or building. Material Sufficient for Level Installation
v, For adequate maintenance and airflow clearance, the
Dig a rectangular area approximately 5 in (127
=r area above the generator should be at least 5 ft"(1.52 m)
mm) deep [A] and about 6 in (152 mm) longer and
with a minimum of 3 ft(.91 m)at the front and ends of the wider [B] than the footprint of the generator. Fill
enclosure. This would include trees,,shrubs and bushes. with 4 in(102 mm)of pea gravel[C], crushed stone
Vegetation not in compliance with these clearance or any other non-combustible-material sufficient for
parameters could obstruct air flow. In addition, exhaust
fumes from the generator could inhibit plant growth. See level installation. Compact and level the material.A
concrete pad can be poured if desired or required.
Figure 3-7 and the installation drawing within the owner's
manual for details. The pad should be 4-5 in (102-127 mm) thick,and
extend 6 in (152 mm) beyond the outside of the
generator in all directions.
Automatic start-up. Disconnect utility power and
render unit inoperable before working on unit.
Failure to do so will result in death or serious injury. _
(000191)
R B
� O O
Asphyxiation. Running engines produce
carbon monoxide, a colorless, odorless,
poisonous gas. Carbon monoxide, if not
avoided,will result in death or serious injury.
(000103)
000856
If the generator is not set to the OFF mode, it can crank Figure 3-3. Compacted Gravel Pad
and start as soon as the battery cables are connected. If
the utility power supply is not turned off, sparking can NOTE: If a concrete pad is required, follow all applicable
occur at the battery posts and cause an explosion. Federal, State or local codes.
Site Preparati®n
• Locate the mounting area as close as possible to
the transfer switch and fuel supply.
• Leave adequate room around,the area for service 000611a
access (check local code), and place high enough
to keep rising water from reaching the generator. Figure 3-4. Poured or Pre-formed Concrete Pad
• Choose an open space that will provide adequate
and unobstructed airflow. Transportation Recommendations
• Place the unit so air vents won't become clogged Use a two wheeled hand cart or metal rails to carry the
with leaves, grass, snow or debris. Make sure generator(including the wooden pallet)to the installation
exhaust fumes will not enter the building through site. Place cardboard between the hand cart and the
eaves, windows, ventilation fans or other air generator to prevent any damage or scratches to the
intakes(see Site Selection). generator.
• Select the type of base, such as but not limited to
gravel or concrete, as desired or as required by
local laws or codes. Verify your local requirements
before selecting.
Installation Guidelines For 60 Hz Air-cooled Generators 13
INSTALLGAS.COM
201 Northwest Dr., Suite 1
Farmingdale, NY 11735
Plumbing Permit Attachment
Date: ► 13118
Property Owner: BILL ERHARDT
11985 SOUNDVIEW AVENUE
SOUTHOLD, NY 11971
631-875-5134
Notes: 1.All above ground piping to be galvanized
2. Isolation valves to be installed at meter&at generator
3. Warning tape to be installed 6" below grade
4.Trace wire to be installed with gas pipe
5. Gas risers to be approved type
6. Gas piping to be approved plastic
7.Size Generator: KW BTU/HR RATING )-750000
8. Pipe length: ) A%
9. Pipe Diameter:
3
GAS METER/
SHUTOFF
SHUT OFF VALVE
PROPANE TANK VALVE `
� y
GRADE
18"
GENERATOR
GAS PIPE