Loading...
HomeMy WebLinkAbout41559-Z 4�S�EFQ�' c® Town of Southold 5/31/2018 Gym P.O.Box 1179 a -- o • 53095 Main Rd 'ffjDl �ao� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39678 Date: 5/31/2018 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1205 Soundview Ave Ext, Southold SCTM#: 473889 Sec/Block/Lot: 50.-2-13 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/17/2017 pursuant to which Building Permit No. 41559 dated 4/24/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels on an existing one family dwelling as applied for The certificate is issued to Haratunian, Stephen&Arda of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 41559 8/10/2017 PLUMBERS CERTIFICATION DATED Authorized Signature TOWN OF SOUTHOLD _may BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41559 Date: 4/24/2017 Permission is hereby granted to: Haratunian, Stephen &Arda 21 Middle Dr Manhasset, NY 110301414 To: install roof-mounted solar panels as applied for. At premises located at: 1205 Soundview Ave Ext, Southold SCTM # 473889 Sec/Block/Lot# 50.-2-13 Pursuant to application dated 4/17/2017 and approved by the Building Inspector. To expire on 10/24/2018. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 C - ON TO DWELLING $50.00 Total: $200.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY J This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2110 of I% lead. 5. Commercial building,industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance-from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building.and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00, Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00, Additions to accessory building$50.00,Businesses$50 00- 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy -Residential $15.00, Commercial $15 00 Date. 2/14/17 New Construction: X Old or Pre-existing Building: (check one) Location of Property: 1205 Soundview Ave Southold House No. Street Hamlet a Owner or Owners of]Property: Arda and Stephen Haratunian Suffolk County Tax Map No I000, Section 50 Block 2 Lot 13 Subdivision �[ e� Filed Map. Lot: Permit No. I 1 Date of Permit. Applicant: GreenLo is LLC Health Dept.Approval: Underwriters Approval: Planting Board Approval: Request for: Temporary Certificate Final Certificate: X (check one) Fee Submilted: $ 50.00 Applicant Stgnature pE SOU��®l Town Hall Annex Telephone(631)765-1802 54375 Main Road C Fax(631)765-9502 P.O.Box 1179G roger.richertCaD-town.southold.ny.us Southold,NY 11971-0959 COW N 9 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Haratunian Address: 1205 Soundview Avenue Ext.. city.Southold st: New York zip: 11971 Building Permit#: 41 559 Section: 50 Block. 2 Lot: 13 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Green Logic License No: 43858-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer RecptEmergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures 11 TVSS Other Equipment: 13.120 KW Roof Mounted Photovoltaic System to Include: 41- Sun Power 320 Panels, 1- SB 6000 Inverter, 1- SB 7000 Inverter, AC Disconnect. Notes: Inspector Signature: Date: August 10, 2017 0-Cert Electrical Compliance Form.xls J A M E S J. S T 0 U T A R C H I T E C T & Assoc. 2 GREG LANE EAST NORTHPORT N. Y. 631 - 8 58 9388 Post Installation Letter August 24, 2017 RE: Haratunian Residence 1205 Soundview Ave. Southold, NY 11971 To Whom It May Concern: This letter is to confirm that as of this date August 24 2017, I, James J Stout, NYS license 021633 have personally inspected the placement and installation of the roof top solar panels at the above listed address.All of the solar panels have been installed as per manufacturer's guidelines and specifications. The racking system design and installation complies with the 2016 NYSRC and 2016 NYSUCS building code and all related provisions. The installation of panels was done as per plan. James J. Stout Architect D � D AR �.5 AUG 2 9 2011 orf 021633 y0� OF NES a. FIELD INSPECTION REPORT7 DATE COMMENTS FOUNDATION(IST) ------------------------------------ FOUNDATION (2ND) NO ROUGH FRAMING& PLUMBING INSULATION PER N.Y-. STATE ENERGY CODE FINAL AD ITIONAL COMMENTS .� aR I '1 c 1 -o z m b � z d N TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 / Planning Board approval FAX: (631)765-9502 � � � Survey SoutholdTown.NorthFork.net PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined 20 Storm-Water Assessment Form Contact: Approved 20 Mail to: GreenLogic LLC Disapproved a/c 425 County Road 39A,Southampton, NY 11968 Phone: 631-771-5152 Expiration ,20 Building Ins ect DD�� 1 7 Za1 APPLICATION FOR BUI ING PERMIT Dae aN 14 920 17 BUILDING DEFT. INSTRUCTIONS 'DOWN OF SOUTHOLD a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit., d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building,Inspector may authorize,in writing,the extension of the permit for an addition-six months.Thereafter,a new permit shall-be.required. APPLICATION IS'HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. GreenLogic LLC (Signature of applicant or name,if a corporation) 425 County Road 39A, Southampton, NY 11968 '(Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer,general contractor, electrician,plumber,or builder Contractor Name of owner of premises Arda Haratunian (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. 40227-H Plumbers License No. N/A Electricians License'No. 43858-ME Other Trade's License No. N/A 1. Location of land on which proposed work will be done: 1205 Soundview Ave Southold House Number Street Hamlet County Tax Map No. 1000 Section 50 Block 2 Lot 13 Subdivision Filed'Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Single family dwelling b. Intended use and occupancy - , Single family dwelling 3. Nature of work(check which applicable):New Building' Addition Alteration Repair Removal Demolition Other Work Roof mounted solar electric system (Description) , 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units _Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front _ " Rear Depth Height Number of Stories r _. �, > i t` )j 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of,lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in'which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO X " 13.Will lot be re-graded?YES NO X Will excess fill be removed from premises?YES NO 1205 Soundview Ave 14.Names of Owner of premises Arda Haratunian Address qoi jthnlciN Phone No. 631-298-7900 Name of Architect —30145 MAL Art b i Address!M , 'r�Omar�tl ne No (031— Name of Contractor GreenLogic LLC Address 425 county Rod 39A Phone No. 631-771-5152 Southampton, NY 11968 ,,,,- 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO X ( �' �00 * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland? * YES X NO * IF YES,D.E-.C.PERMITS MAY BE REQUIRED. ' 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on.survey. 18.Are there any covenants and restrictions with respect to this property? *YES NO X * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Nesim Albukrek being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contractor (Contractor,Agent;Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this t- day of Fe 20_Lj_ Notary Public Signature of Appli ant SAMANTHACORBErr Notary OuOic,Staff of Nov York Reg,No.01CO6335944 Quaii,sd In Suffoiic Cou* COMMExpins Januar'19,2020 IN 50'l.- d 11•\t< 1-�I?I0 { j ��31h3�1 101 lu311111ed3(I ;,ul.raata;,tt {of p-Pwo,l) palml7aZl�zI I'tId 100fillo-) I,J1111173�{ jt,\ ue1cl 1011u0J tu3tuacralnI,\ laar\, 11.101` 6LU( �N P OWI S any nnainpunoS 9OZ� 1n11.1a�{ nll7lntfl SIII"3.x,td In{ pauold(I\' %I lac c)Id �Z5�5-ALL-�O9 '. ,ru:tr,tl•7r,:nt L(/17 UZ ( --0� a ykS 11 I O E 11\\ !t,)q:O olmIi uq) {ud'o,,, 'xmaq,,loI i,1,w,l(t t,ut.ok');t-,.>�lo'd I\1.71'ldr{b a 0001 :, IN,.1, 7'S •uoiluallddb l]uiaad Suipling .mon gjIm juitu1 tO(I Snip{Ing aq1 of tujo_4 1sI I xaag) palaldutoa u pun 11uld lognoj JwtuoSuau`r 101PAuu-1015 u to smdoa om j limgns asuald `aeoclu '3111 Jo "oto .10 0110 01 S3A pa.laAlsuu non 3I •laafo.ld.moi 01 nlddu lou scop �)tF taldugj i.lagmny dulti xuZ nluno) N, alu(l •110{1liu1.1o3n1 inluo) 'a1njr0IS `0u1uN anon gllA►A1opq 11oilaas luuailddV agl alaldtuoj idOiS ',3Aogt suollsanb act)do llu of OA[ p3ntisue noxi ll �C 'Sao,c jjnq S]10IA.I@duj1 Jo .1u@woJL'jC1a.1 pt11�j-Lll sapr11Jt11 jLgodo_Id @(.11 puP tl_\\o aLjj !�q pa-\raJa.I fiL_\\ u>✓jCj jo.l�tro� Iu01LlanPLIPjN .{a1VA\111,1015 L J-0 IP.:\O.IddP _101.14 cgajLlll `'3.10111 .10 -Iaaj a.ILIlb; 000`1 JO S_aJL'J.InS SI10IA.IadLUI PQJL'J.Ill',-a.l .10 _Y\au JO LIO1_jLjji?_j��LIj _1 �X as_rnoJ_1a�rn\ "L' Jo 4L1N NUH 110 pajJidap qu LIIPjdpoolj Jva_"_pa.Ipurltj-3tl0 aLj.1 u11.111AA LJOIju.ludo.ld all( '1 Qx 'Pa.IP p-IPZPLj 1_I01fiO_Ia jPj,,;POJ .10 jjnjq `gZ)L'aC1 `gpuPjl3—A\ JO JaaJ 001 uoflu.1Pdo.ld ;D IS 'l7 R❑ 'aJuPjr,Ip jr,ILloz1.I0L1 Jo Iaaj 001 01 aSl-I jP31j.Ia-\ jaaj 01 paaJXa tpfq_Y\ �adojc, UO 1-1011L'.IPda.Id aIIS 'J ❑X ❑ 'Pa_IP Mon.OTILIOJ _1LIP ,10 1@3JUCI A"LIP LIIL111." IP1.I31m jo gp_lPr1 JIC1113 00Z LI1?Lj:1 a.IOU1 .AlIA10:1t11 u111rJ .10 uo]jP!\P.J\] 'q 'a3UP11; pLI110_ff jO 1aaJ a_IPnb`; 000,9 uPLP a.10UT SPajJL L1JIL1 \\ pL]Lj J0 OLIICICII_I�� .IO 0u1pP_10 `0Lf1C1C111.10 ./ 'V ❑X t"Wd\ 1\111,1 '1"IF Nilllh \ :')NU:A\.UTIOJ: M-11 10 A \i�c' ;x i'1C1:\.�T. 13,4rMTJ �,T'IHJ, y:lC1C7 (1:1_1-TICHNIC)') 7q C)_I, ) 1219HS XHOAI Zig 9W2[f)VNM HUIVAI "01S - 9j7Z W211JVH,-) ��, 1 p1o� Yl � oSfo uMo, T ro /, IL611 >luoA n13N'alOH i.nos-N«a tt1"Iv S60CS �� � 6L11 `��A'O'd-`l'IVFINA10LC1"lON_LnOS �][�CJL\�IA�\][��IZ][� �J assn o� From GreenLogic LLC Fax-(877)771-4320 To Fax. (631)765-9502 Page 1 of 1 0211612018 11.09 AM ATTN: Roger Richert of S(I(/r'yo Town Hall Annex Telephone(631)765-1802 W75 Main Road ��ax g Itl P.O.Sox 1179 G Q roger.richert—ow .SOU hO 5 ny.us Southold,NY 11971-0959Q�� BUILDING DEPARTMENT TO"OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: samantha Corbett Date: 2/16/1, Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME Address- 425 County Road 39A, Southampton, NY 11968 Phone No.: 631-771-5152 JOBSITE INFORMATION: (*Indicates requited information) ' *Name: Arda And Ste hen Haratuniand IVCe,d?8 *Address: 1205 1205 Soundview Ave Southold, NY 11971 *Cross Street: Lighthouse Rd - ''- *Phone No.: ' -771-5152 Ext.107 �i 6red Permit No.: 41559 7 Tax-Map District: 1000 Section: 50 Block: 2 Lot: 13 *BRIEF DESCRIPTION OF WORK(Please Print Clearly) 13.120kW Roof mounted solar electric system with micro inverters. (Please Circle All That Apply) *Is job ready for inspection: YES NO Rough in Final *Do you need a Temp Certificate: ES NO Temp Information(if needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION �©o,co Sgq,-7R 82-Request for Inspection Form �� // AOF SO�lyo! d Town Hall Annex 1 Telephone(631)765-1802 54375 Main Road y (630765- 630 765-g5 P.O.Box 1179 G • OQ ro er.richert town.SOut95iJ5.n s Southold,NY 11971-0959 �l y410l�m,� BUILDING DEPARTMENT Pd TOWN OF SOUTHOLDVVV �/j� I APPLICATION FOR ELECT INSPECTION i l REQUESTED BY: Samantha Corbett Date: 2/14/17 ' Company Name: GreenLogic l-l-C I Name: Robert Skypala s License No.: 43858-ME I Address: 425 County Road 39A, Southampton, NY 11968 al Phone No.: 631-771-5152 JOBSITE INFORMATION: (*Indicates required information) ° Name: Arda and Stephen Haratunian *Address: 1205 Soundview Ave, Southold, NY 11971 a 6 *Cross Street: __ -- --_----_----_ i Li hthouse Rd C-06' *Phone No.: 631-771-5152 Ext. 107 a i Permit No.: ISS Tax-Map District: 1000 . Section: 50 Block: 2 Lot: 13 / i *BRIEF DESCRIPTION OF WORK(Please Print Clearly) 13.760kW Roof mounted solar electric system with micro inverters. (Please Circle All That Apply) � �- *Is job ready for inspection: ��� YES NO Ro9h I � Z0 Final *Do you need a Temp Certificate: YES NO I Temp Information (If needed) mt-4 io ego' wl& 'J qz�' Wwull PUZ *Service Size: 1 Phase 3Phase 100 r 'f ` o 4 ,� 01 c. 150 Z�0 �QQ 350 ,400 �ther � �`'`�-' *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION C 82-Request for Inspection Form I i Lf I GEENL®GIC° ENERGY February 14, 2017 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Dear Building Inspector: Please find attached a building permit application on behalf of the Haratunian residence who has engaged us to install a roof mounted solar photovoltaic (PV) electric system for their home located at 1205 Soundview Ave, Southold NY. In connection with this application, please find attached: • Building Permit application • A Storm Water Assessment Run-off Form • Certificate of Occupancy Application • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports (3 originals and 1 copy) • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels • 2 Spec. sheets for Racking System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200 ($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, Sacs"Wda 6o2� Samantha Corbett Account Manager Samantha.Corbett@Greenlogic.com 631-771-5152 ext. 107 GREENLOGIC LLC o www.Green Logic.com Tel 877.771 4330 Fax 877.771.4320 SOUTHAMPTON ROSLYN HEIGHTS 425 County Rd 39A 200 S Service Rd ,#108 Southampton, NY 11968 Rosyln Heights, NY 11577 GREENLOGICO ENERGY August 25, 2017 The Town of Southold Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Re: Building Permit No. 41559 Arda Haratunian 1205 Soundview Ave Ext, Southold To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the above referenced address. Can you please close the building permit and send the Certificate of Occupancy? Please let me know if you need additional information regarding the installation. Sincerely, Scuruuctla Samantha Corbett D �CRD'V[E Account Manager DD Samantha.Corbett@Greenlogic.com AUG 2 9 2017 631-771-5152 Ext. 107 BUILDING DEPT. TOWN OF SOUTHOLD GREENLOGIC LLC - www.GreenLogic.com Tel 877.771 4330 Fax: 877.771.4320 SOUTHAMPTON ROSLYN HEIGHTS 425 County Rd.39A 200 S Service Rd ,#108 Southampton, NY 11968 Rosyln Heights, NY 11577 3 GREENLOGICO ENERGY May 25, 2018 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Attention: Roger Richert Re: 1205 Soundview Ave Ext, Southold Permit NO. 41559 Dear Roger: Per our phone conversation, enclosed please find the revised electrical application which now indicates the correct equipment that was installed at the above referenced home. Can you please forward me the electrical and building Certificates of Compliance at your earliest convenience? Thank you and please let me know if there is anything else you may need. Please let us know if you need anything else in connection with this application. VYours truly, 2 D el"& a MAY 2 9 2018 Barbara Casciotta BUILDING DEPT. Account Manager TOWN OF SOUTHOLD Barbara@Greenlogic.com 631-771-5152 ext. 117 GREEN LOGIC LLC o www Green Logic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd , Suite 3 200 S Service Rd ,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 LONG "SLSURVEY OF PROPERTY S 74.20, AND SITUATE ^°PAaEM 5q"e SOUK SOUTHOLD "G" D TOWN OF SOUTHOLD y MAIN "E 13p04' SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000-50-02-13 �W S 77•01'pg•• a SCALE 1"=30' 1r. APRIL 9, 2014 1}` 110.9g, JUNE 9,2015 ADD PROPOSED ADDITIONS Os SEPTEMBER,2015 REVISE NOTES AND SEPTIC SYSTEM NOVEMBER 11,2015 ADD STREET TIE DISTANCE FEBRUARY 16,2016 REVISE PROP SEPTIC�SSYSTEMPPESEPTIC RE S C SYSTEM H 5 NOTICE 02/11/2016 SEPTEMBER 14,2016 FOUNDATION LOCATION AREA = 70,459 sq ft. 1.617 ac s 11,61CERTIFIED T0. If 00, STEPHEN HARATUNIAN J� ARA HARATUNIAN Os \\dJ• OBD c � 044E \� y pP06FOFJ N 0 TURF BUFFE P TO �RD (JARO W 01 56- 4yP SO. 0 EDGE OF L t YJ \g / .y \ / CO ,OM1 I VIP 1 EUVATIOfS RE REFER NCO TD NAVO 19M DATUM COVING EIEYATION3 RE SHOWN THUS / o, OUSTING CONTOUR LINES ARE SHOWN THUS. I MINIMUM SEPTIC TRK CAPACITIES FOR A 1 TO 4 BEDRCOM HOUSE IS 1.000 GA \ 1 TRK,B'LONG Y-]'MTD[.6'-7'DEEP LLD" �5. ]YINIYUM LEACHING SYSTEM MR A 1 TO 4 BEDROOM HOUSE IS 300 p 1t SURMALL MEA. 'A \ I POOL 12 DEEP.8'dla. }1 r • / PROPOSED EAPANSION POOLr��aHN \ CNOD 40 20p PROPOSED—NUIG POOL R a' PROPOSED SEPIIC TRK 4 THE LOCATION OF WELLS AND CESSPOOLS SHOWN HEREON ME FROM FROG OBSERVATIONS MO/OR DATA OBTAINED FROM OTHERS. 'E?, •O 8 DED151TAREAURBEO AREA C(LOT AREA TODSILT PENCE LINE)=231,S30 Pip ev gV,O11++ • �EMkO, qa 0 01 a Sao a rya 00 0'Ca *i b PREPARED IN ACCONDWCE MIH 1XE YIWUUY f AVWi05 NR TIII£Su—AS ESTABUSHED 9Y THE DAIS.RO APFRD/m AND AOpP1E0 tIR SUCH USE W THE NYORN STALE—DO NE EW ASSOWTaN O�y G40 NYS Lrc No 50467 o�°SU�1�.A ON�°pN Nathan Taft Corwin III SECGW 1N9 OF 1HE NEW YOro(STALE MaL m"��" W Land Surveyor INE 112 EUMCU INNEU sFAL DRAW ONmzsm srra sNAu NDT 12 mNvomm ro BEA—TRUE COPY yylL puN Succ<eSv To SlOnley J Isokeen,JF LS araYYD TiE pL ox rpt"�MiO°Nil ME sumM Jaupb A Nge9no LS i3 PREPARED 0 ON N5 BDYEF TO TxE mL CONPANr OpNNNUO6N.ACENCY ANO ]TIM S—m —SUbdiWsmn9—Ste Pkne— ConsOuabon Layout IMFMaf6E NtROUIaN ISLFD MEREW,AND _ PHONE(631)727-2090 Fax(631)727-1727 THE IXISTENC[OF RIGHT OF WAYS OFFICES LOCATED Al AWLING ADDRESS ANO/.NEASEMENTS OF RECORD,N 1586 U. Rood PO BOK 16 ANY,NOT]MOWN ARE NOT OUAj ED Jamesport,Net Yark 11947 Jam,,p t,Net York 11947 c } APPROVED AS NOTED DATE:`!' -P.#? , 43 CO"�? LY Oar!-FN ALLCODES OF NEW YORK STATE & TOWN CODES FEE: _.. �-.. Rv'� ,4S REQUIRED NOTI BUILD!I'lG -L-PARTMENT AT 765-1802 SAM 70 t Ptvl FOR THEC I Tuna n Tn!a;ai- �n r�.4� FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED SQ FOR POURED CONCRETE S wI1 -1) ; U5 i ft 2. ROUGH - FRAMING & PLUMBING 0. INSULATION N.Y f)!y. ---- G. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C 0. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. OCCUPANCY O USE IS UNLAWFUL WITHOUT CERTIFICATE LEECTMAL OF OCCUPANCY RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. i Fill: 1111 Fill Jill III I A M E S J. S T € UT A FCHITECT Assoc. G REG LANE EAST NoI. TRPORT N. Y. 891 — a 5e e,9s8 Letter of Certification April 13,2017 RE: Haratunian Residence 1205 Soundview Ave Southold, NY 11971 To Whom It May Concern: I,James J. Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above- mentioned address and have determined the structure and the panel attachment to be adequate to support the new additional load imposed by the proposed solar panel system and complies with the 130-mph wind design load as 2016 New York State Uniform Code(2016 NYSUC),2016 New York State Residential Code(2016 NYSRC)=(2015 International Residential Code (2015 IRC) (2nd Printing)and 2016 New York State Uniform Code Supplement(2016 NYSUCS)and the 2014 National Electric Code NFPA 7012014 National Electric Code. The. Roof rafters will provide the required support.The existing asphalt roof has 1 layer of shingles on 15#building paper on V plywood sheathing. Thank you for your understanding in this matter. James J.Stout A} 0 16 4 € OF tN4 GREENLOGICr ENERGY GreenLogic,LLC Approved Haratunian,Arda 1205 Soundview Ave Southold,NY11971 Surface#A: Total System Size:13 120kW Array Size:6.400kW 2 Strings of 7 and 1 String of 6 on SB- 6000TL Azimuth:212° Pitch:2° Monitoring System. SunPower Panel/Array Specifications: Panel.SPR E20-320 Racking:SunPower InvisiMount Panel:61.39"X 41.18" Array 370.62"X 143.75" Surface:322"X 14' Legend: 20 SunPower 320W Panel ® SunPower InvisiMount Rad • 62 Eco-Fasten Fast Feet Ba TJI360's 9.5"Deep at 16"O C Notes Number of Roof Layers 1 Height above Roof Surface-6" Materials Used Eco-Fasten,SunPower, SMA Added Roof load of PV System:3.5psf Engineer/Architect Seal: AR w Oo x xy ¢ 02163_'' k OF V vE awn By.MVP Drawing#1 of 8 ate:11/7/16 REV:A Drawing Scale.3/16"=1.0' ENERGY GreenLogic,LLC Approved Haratunian,Arda 1205 Soundview Ave Southold,NY11971 IN Surface#A: Total System Size:13.120kW Array Size:6.400kW 2 Strings of 7 and 1 String of 6 on SB- 6000TL 13 Azimuth-212° Pitch:2° w` Monitoring System: \v SunPower Panel/Array Specifications: Panel:SPR E20-320 Racking.SunPower InvisiMount Panel.61.39"X 41.18" Array:370.62"X 143.75" Surface:32'2"X 14' Legend: ® 20 SunPower 320W Panel ® SunPower InvisiMount Rad • 62 Eco-Fasten Fast Feet 8 TJ1360's 9.5"Deep at 16"O.C. Notes• Number of Roof Layers:1 Height above Roof Surface:6" Materials Used:Eco-Fasten,SunPower, SMA 11 1 1 AL Added Roof load of PV System:3.5psf Engineer/Architect Seal: AN j , Asq ZI-E 0 t W 9 02163' COQ awn By:MVP Drawing#2 of 8 ate:11/7/16 REV:A Drawing Scale.3/16"=1.0' m O ENERGY GreenLogic,LLC Approved AN Haratunian,Arda 1205 Soundview Ave 3 Southold,NY11971 Surface#A: Total System Size:13.120kW Array Size:6.400kW 2 Strings of 7 and 1 String of 6 on SB- 6000TL 3 Azimuth 212° Pitch:2° Monitoring System: SunPower Panel/Array Specifications: 3 Panel:SPR E20-320 Racking:SunPower InvisiMount Panel:61.39"X 41.18" Array:370.62"X 143.75" Surface:32'2"X 14' Legend: ® 20 SunPower 320W Panel 2 SunPower InvisiMount Rad • 62 Eco-Fasten Fast Feet TJ1360's 9.5"Deep at 16"O.C. Notes- Number of Roof Layers 1 2 Height above Roof Surface:6" Materials Used:Eco-Fasten,SunPower, SMA Added Roof load of PV System 3.5psf Engineer/Architect Seal: ti\A AR z �\C7'� �C' 7 ST O❑ 1 2 q 021633 ,t0Q O� NES rawn By MVP Drawing#3 of 8 Date:11/7/16 REV:A Drawing Scale:3/16"=1.0' ENERGY GreenLogic,LLC Approved Haratunian,Arda 1205 Soundview Ext Southold,NY 11971 Surface#B: Total System Size:13.120kW Array Size:6.720kW 2 Strings of 7 and 1 String of 7 on SB- 7000TL Azimuth-178° Pitch:12" Monitoring System: N SunPower Panel/Array Specifications: Panel:SPR E20-320 Racking.SunPower InvisiMount Panel:61.39"X 41.18" Array:184.17"X 288.26" Surface:17'1"X 24'10" Legend: ® 21 SunPower 320W Panel ® SunPower InvisiMount Rail • 56 UniRac 4"Drk Standoffs B 2x12"Douglas Fir Rafter 16" O.C. Notes: Number of Roof Layers-1 Height above Roof Surface:6" Materials Used:UniRac,SunPower,SMA Added Roof load of PV System:3.5psf Engineer/Architect Seal: Alq S 3T 4✓ >k -9 102, ,-3 € OF tdE`� . �"Vrawn By:MVP Drawing#4 of 8 Date:11/7/16 REV:A Drawing Scale.3/16"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Haratunian,Arda 1205 Soundview Ext Southold,NY 11971 Surface#B: Total System Size:13.120kW Array Size:6.720kW 2 Strings of 7 and 1 String of 7 on SB- 7000TL Azimuth:178° Pitch:12° Monitoring System: N SunPower Panel/Array Specifications: Panel:SPR E20-320 Racking:SunPower InvisiMount Panel:61.39"X 41.18" Array:184.17"X 288.26" Surface:17'1"X 24'10" Legend: ® 21 SunPower 320W Panel ® SunPower InvisiMount Rail • 56 UniRac 4"Drk Standoffs BB2x12"Douglas Fir Rafter 16" Notes: Number of Roof Layers:1 Height above Roof Surface:6" Materials Used-UniRac,SunPower,SMA Added Roof load of PV System-3.5psf Engineer/Architect Seal: 1 177 EIR AR -y 0 1633 COQ` OF rawn By:MVP Drawing#5 of 8 Date:11/7/16 REV:A Drawing Scale:3/16"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Haratunian,Arda 1205 Soundview Ext Southold,NY 11971 Surface#B: Total System Size:13.120kW Array Size:6.720kW 2 Strings of 7 and 1 String of 7 on SB- 7000TL 4 5 6 Azimuth:178° Pitch:12" Monitoring System: N SunPower 4 56 Panel/Array Specifications: Panel:SPR E20-320 Racking:SunPower InvisiMount Panel.61.39"X 41.18" 4 5 6 Array:184.17"X 288.26" Surface:17'1"X 24'10" Legend: 21 SunPower 320W Panel 45 6 84SunPower InvisiMount Rad • 56 UniRac 4"Drk Standoffs 8 2x12"Douglas Fir Rafter 16" O.C. 5 6 Notes: Number of Roof Layers:1 Height above Roof Surface:6" Materials Used:UniRac,SunPower,SMA 4 5 6 Added Roof load of PV System:3.5psf Engineer/Architect Seal: �R a�q 4 5 6 y 02163'' y0� 0 NES awn By:MVP Drawing#6 of 8 ate:11/7/16 REV:A Drawing Scale:3/16"=1.0' GREENLOGIr ENERGY GreenLogic,LLC Approved Haratunian,Arda 1205 Soundview Ave Ext Southold,NY 11971 Total System Size:13.120kW 2 strings of 7 and 1 String of 6 on SB- 6000TL 2 strings of 7 and 1 string of 7 on SB- 7000TL Azimuth:° Pitch- Monitoring System: N SunPower Panel/Array Specifications: Panel:SunPower 320w Racking:SunPower InvisiMount l Panel:61.39"X 41.18" x x Legend: I ® SunPower 320W Panel x x ® SunPower InvisiMount o UnlRac 4"Drk Standoffs/Eco- Fasten Fast Feet � Notes• Number of Roof Layers:1 Height above Roof Surface:6" Materials Used Eco-Fasten,SunPower, SMA x x Added Roof load of PV System-3.5psf Engineer/Architect Seal: xxx � B AR �k q OZ 163'' ypQ OF �E� Ya awn By P Drawing#7 of 8 te:11/7/16 REV:A Drawing Scale:1/8"=1.0' C GREENLOGIC �p ENERGY GreenLogic,LLC Approved Haratunian,Arda 1205 Soundview Ave Ext Southold,NY 11971 Total System Size:13.120kW 2 strings of 7 and 1 String of 6 on SB- 6000TL 2 strings of 7 and 1 string of 7 on SB- 7000TL Azimuth:° Pitch:° Monitoring System: N ( ! SunPower - 1 �- �- - -- --- - Panel/Array Specifications: A1C_ m Panel SunPower 320w Racking:Su Mount _L if�4'D1CRfs $. _ _ Panel:61.39' X 41.18"visi 3G'SC3rIE�S�V�I135 _ - Legend: SunPower 320W Panel SunPower InvisiMount _ ' tFee�'E�eepa>e EP- 0! UniRac 4"Drk Standoffs/Eco- �F "FF�"/�ur�r �pdc Q ! Fasten Fast Feet EmWaStat'YffitF&-ff Nfaadirg Q 4&4WtH C-GAg.53EW 19 Notes: Number of Roof Layers:1 M.4.WtH Gauddrub / _ 372 _ Height above Roof Surface:6" Materials Used.Eco-Fasten,SunPower, t _ .�...�'.._..,.._.,_..... .__.,....._.,..... .........�..........,�. � � - � __- .< SMA I Added Roof load of PV System.3.5psf - - - Engineer/Architect Seal: L— 4EVk At? Sr i �I 021 3'5 yOQ OF rawn By:MVP Drawing#8 of 8 Date:11/7/16 REV:A Drawing Scale:1/8"=1.0' FQ Weem sNount Simple and Fast Installation ��- Integrated module-to-rad grounding R 1 Pre-assembled mid and end clamps !! Levitating mid clamp for easy placement ! - Mid clamp width facilitates even module spacing -- -�— - Simple,pre-drilled rail splice UL 2703 Listed integrated grounding _ Flexible Design - Addresses nearly all sloped residential roofs Design in landscape and portrait Rails enable easy obstacle management " Customer-Preferred Aesthetics #1 module and#1 mounting aesthetics Best-in-class system aesthetics Elegant Simplicity Premium,low-profile design Black anodized components SunPower° InvisiMountTm is a SunPower-designed Hidden mid clamps and end clamps rail-based mounting system.The InvisiMount system hardware,and capped,flush rails addresses residential sloped roofs and combines faster Part of Superior System installation time, design flexibility, and superior aesthetics • Built for use with SunPower DC and AC modules The InvisiMount product was specifically envisioned and Best-in-class system reliability and aesthetics • Combine with SunPower modules and engineered to pair with SunPower modules. The resulting monitoring app system-level approach will amplify the aesthetic and installation benefits for both homeowners and installers eY 11kv ,. sunpower.com a Z r FD SUNPOWEn "Ma"cOUinlo,�O "how - Module*/Mid Clamp and Rail Module*/End Clamp and Rall Mid Clamp End Clamp Rail&Rail Splice Ground Lug Assembly End Cap �`— 1 Component Material Weight Temperature -40°C to 90°C(-40°F to 194°F) Max Load 2400 Pa uplift Mid Clamp Black oxide stainless steel AISI 304 63 g(2 2 oz) 5400 Pa downforce End Clamp Black anodized aluminum alloy 6063-T6 110 g(3 88 oz) Rail Black anodized aluminum alloy 6005-T6 830 g/m(9 oz/ft) 0 ° f t or, ®We M-Meff"19 Rail Splice Aluminum alloy 6005-T5 830 g/m(9 oz/ft) Warranties 25-year product warranty Ground Lug 304 stainless 5-year finish warranty Assembly (A2-70 bolt,tin-plated copper lug) 106 5 g/m(3 75 oz) End Cap Black acetal(POM)copolymer 10 4 g(0 37 oz) UL 2703 Listed Certifications Class A fire rating when distance between h o o o w )1 Sudo omooijv� roof surface and bortom of SunPower , 0- -jam Ifo o� module frame is<_3 5" Composition Shingle Rafter Attachment - Application Composition Shingle Roof Decking Attachment ffidAM20MM HOFdow"W% M Curved and Flat Tile Roof Attachment Universal Interface for Other Roof Attachments Refer to roof attachment hardware manufacturer's documentation *Module frame that is compatible with the InvisiMount system required for hardware interoperability ©2015 SunPower Corporation All Rights Reserved SUNPOWER,the SUNPOWER logo,and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation,All other trademarks are the property of their respective owners sunpower Com Specifications included in this datasheet are subject to change without notice Document#509506 Rev B PO) 7 11 j C!"OT—, V _"11---------- 4 g _1SZ A -CIA & 'S j Ir" 4 a 6 N, "M �6 411 4" MAY"-MCI ZT, gse" '*'j 4 I THE WORLD"S ONLY 'M, n� SECURE POWER SUPPLY "n U•K K V11% A '711� V 4 Certified Innovative Powerful Flexible •UL 1741-and 16996 compliant •Secure Power Supply provides •97 6%maximum efficiency •Two MPP trackers provide •Integrated AFCI meets the require- daytime power during grid outages •Wide input voltage range. numerous design options ments of NEG 2011 690.11 •Shade management with OpliTrac .-Extended operating Global Peak MPP tracking temperature range SUNNY BOY 3000TL-US 380OTL-US /4000TL-US 5000TL-US / 6000TL-US / 7000TL-US / 770OTL-US Setting new heights in residential inverter performance The Sunny Boy 300OTL-US/380OTL-US/AOOOTL-US/500OTL-US/600OTL-US/700OTL-US/770OTL-US represents the next step in performance for UL certified inverters.Its transformerless design means high efficiency and reduced weight.Maximum power production is derived from wide input voltage and operating temperature ranges. Multiple MPP trackers and OptiTra(: m Global Peak mitigate the effect of shade and allow for installation at challenging sites.The unique Secure Power 10 L 04 Tlip Supply feature provides daytime power in the event of a grid outage. High performance, flexible design and innovative features make the Sunny Boy TL-LIS series the first choice among solar professionals. 0 9 W-A %P qV -""D,P-'so Sunny Boy 3900TL-US Technical data Sunny Boy 3800TL-US Sunny Boy 1090Y]L-US 208V AC V AC 268VAC 240VAC 208 V AC 240 V AC Input(DC) Max. bt power(@ cos 4=-1) Max,PC voltage 600 V 600V 600 V gated Mvpf);atage range -1-75-460 V 480-V- 175-480 V, MOT operating voltage range 125--500 V-__ i 25 506 V 500 V Min PC voltage/start voltage 125 V/150 V 125 V/150V 125 V/-150 V' Max,operating inputcurLerjt/per MPP tracker 24A/15A 24.A/ A '�er of PP trackstrings Number Mtrackers- e per!APP tracker 2/2 Output(AC) ACnominalpower,_ 3000 VJ _3336W '3840W 4066 W 1 C apparent power 3000 VA. 3330 VA 3840 UO VA 4000VA Nominal AC voltage/adliusto6f,e 208V/0 246_V)• 268 V j4_ i46V 0 268 V1,* j40_V/_,i__ A(qvpltagerange_ 183-229 V I- 2 .2 2-6_4 V_ -'I 8_3=,229 V_ 2-I'1 -__264 AC grid frequency;range60 Hz 54.3-60:5 Hz 60 Hz/59_3-605 Hz 66 H t Max.output current 15 A 16^Al 20 A Output phases-/ 'connections 1/2 H_ .Rqnonics <4 0 <4% Efficiency a 97.2% 976% 97 2% 975% i 97.2% 975% dC efficiency` 965% 96.5% _97.0% 96,5% 97.0% Protection devices DC disconnection device ___P�C reverse-polarity protection Ground fault monitoring Grid monitoring __, short circuit protection *fpple-sensitive residual current monitoring unit Arc 61t circuit interrupter JkFC11.c9,mpticnt to UL 16998 _Protection class/ovqrvcf!age category General data mterlsloqs in mm(in) 490 j 519 j 185 (19.3 J 20,5 J 7,3)-, 1. DC Disconnect dimensions(W/"H/Dl,in mm (in) 187/297/ 87/297/190 J7,41 11.717.5) -------Ociiclkiri_q-dimensions(W/­H/D_)`in­;�rrt(in) (243/215/)0.5) ,n % bt Disconnect packing dimensions(Wl H D)in mm(in) M RAA/94/_11.0)- 24 k (53 161/13 kg (iJIb}arinpi;hmeight Packing,wpight/,PqP!sconrnct packing weight... 27 kb-j60 lb)/-P,j kq'(8=16) PperafingjtempE�rqture,j9ng9 _40-C, +0-C °F...+140-F), _Noise girpission,ftypical) 5 25 c!B(A)_ -25 A(A) Internal cansumpejori,at nigt'h <I W <I W <,!W - Topology_ TrcmsformerlelssTransformerless- Tronsfiormerfess Cooling Convecligri InV qction Convection uiictrqnics,_protecfion rating NEMA 3R Features Secure Power Supply InierGices.kS485_l S'peedvAre/_W_eb­c_onnect 0/0 0/0 War r qnt �dye. 0 15 */o/6- 61010 •/0 j0. Certificates and pe'rmiis(rWqre,_ovciGb1e on'request) 'UL i741- UL 10'96006996,11tEEIS'47,FCC Part 15(ds_sA&B),CAN/CSA 022.2- 1 0.7.1 1-1 NOTE:US 16merters*ship-V-ithi-gray lid's T U S-2 'Typp designationS8 3000 L- 2 SB 3800T4US-22 B 4000TL-US122 - - - — Efficiency curve SUNNY BOY 5000TLUS-22 240Vac - Accessories 3 ! ••—�• efxannerf ^ � interfaceeN2 DM•485C US-10. 96 .i_ .. ._... •• ....»....... ........ • `. ` ••••••••y SWDM US,,D ' i U 92 Fan kit for SB 3000/3800/ 90 I "• a^ 4000/500OTL-US-22 ` Eta(Vry= - , + FANKIT02-10 88 Eta(V -4175 V)00 V), vs aeo 86 ..,,,,.,... _—•.. Eta 1Vn a 480 V}(. V,_.»IV) , _-._— i 0.o 0.2 04 06 08 1.0 I •Standard feature 0 Optional feature Not ava- ilable Output power Rated power ----------------------------- --------- Data at nominal conditions 9 Sunny Boy 5000TL-US Sunny Boy 6000TIL-US Sunny Boy 7000TL-US Sunny Boy 7700TL-US 208 V AC 240 V AC 208 VAC 240 V AC 208 V AC 240 V AC 208 V AC <' 240 VAC 5300 W 5300 W 7300 W 8000 W 600 V - _ - W 600 V 606 V 600 V - 175-480 V 210-480 V 245-480 V _ 270-480 V - 125_-500 V• 125-500V 125-500 V 125-500 V 125 V/-150V 125V/150V 125V/i50V 125V/150'V __._. .30A/15 A_ -30A/15_A _ _ 30A/18A 30A/38A 2/2 4550 W 5000 W _ _ - 5200 W _ W 6000 W 6000 W 7000W 6650,W 7680 Nl - 4550 VA _ 5000 VA 5200 VA 6000 VA 6000 VA 7000 VA 6650 VA 7680 VP, 208 V/imi 24d'v 208 V/• 240 V/• 208 V/• 240V/0 208 V/• 240 V/�• „1,83-224 V•-_, 211111-264 V 183-_229 V21 1_-264,V 183-229 V 21 1 -264 V 183-_229 V_ 21 1 -26d V_ •; 60 Hz/59 3-60,5 Hz _ 60 Hz/59.3-60 5 Hz, 60 Hz/59.3-60 5 Hz 60 Hz/59 3-60.5 Hz 22A 25 A29.2 A 32 A _. ,. 1./2 •. 1/2` 1/2 _ 1/2 . 974% 968% 96.8% W _ 968°x, .597.3% 96.5% qX0% 96.5% 97 0`a 965% 96.5% .965% 965% = 7- I/IV 490/579%185 (19.3/205/7.3) - _ 187/297,/190 (74/11.7%7.5) - 617/597/266 (2 d.3J 23.5/10.5) 370/240./280 (146/9.4/11.0) - 24 kg (53 Ib)/3.5 kg [Bib) _27 kg-(60 Ib)/_3.5 kg (8 Ib) -40'C- +60'C (-40-F-_-I 40' _ .. 2 9,dB{A} r29,d8{Al :<29 dB(A) <?9 dB(A), V ..,<2 - .. _ ,_. L_. -__ _. ....-. _ _ __. _ ._ _ ,. -_ <1W <1-W= .._ ._ <7W Transformedess Trcinsformerless Tronsformerless- Tronsformerless_rr_- Convection Fan Fan Fan NEMA 3R•. „NEMA 3R NEMA 3R , . _ _ _0/6 .. ! -o/0 0/0 _ . o/o UL 1741,UL 1998,UL 16998,IEEE1547,FCC Part 15(Class A&B),CAN/CSA C22.2 107.1-1 _ __ SB5000TL•US-22 i- SB 6000TL-US-22• __ __ S8 7000TL-US-22 , 5B^7700T1•US•22 __ Big ElmIle Elm More efficient Shade management Easier o •0 a Secure Power Supply "Broad temperature range Flexible communications A NEW GENERATION OF INNOVATION THE SUNNY BOY TL-US RESIDENTIAL SERIES HAS YET AGAIN REDEFINED THE CATEGORY. Transformerless design in all types of climates and for longer periods of Leading monitoring time than with most traditional string inverters. and control solutions The Sunny Boy 3000TL-US / 380OTL-US g / 4000TL-US / 5000TL-US / 6000TL-US / Secure Power Supply The new TL-US residential line features more =} 7000TL-US/770OTL-US are transformerless than high performance and a large graphic inverters, which means owners and installers One of many unique features of the TL-US display The monitoring and control options v: benefit from high efficiency and lower weight. residential series is its innovative Secure provide users with an outstanding degree of u n A wide input voltage range also means the Power Supply. With most grid-tied inverters, flexibility. Multiple communication options t inverters will produce high amounts of power when the grid goes down, so does the solar- allow for a highly controllable inverter under a number of conditions. powered home SMA's solution provides and one that can be monitored on Sunny daytime energy to a dedicated power outlet Portal from anywhere on the planet via an Additionally, transformerless inverters have during prolonged grid outages, providing Internet connection. Whether communicating b been shown to be among the safest string homeowners with access to power as long as through RS485, or SMA's new plug-and-play inverters on the market.An industry first,the TL- the sun shines. WebConnect, installers can find an optimal US series has been tested to UL 1741 and UL solution to their monitoring needs. G 1699B and is in compliance with the arc fault Simple installation .i requirements of NEC 2011. Wide Power Class Range P �v As a transformerless inverter, the TL-US Increased energy production residential series is lighter in weight than Whether you're looking for a model to its transformer-based counterparts, making maximize a 100 A service panel or trying wZ J KI OptiTrac'm Global Peak, SMA's shade- it easier to lift and transport. A new wall to meet the needs of a larger residential PV tolerant MPP tracking algorithm, quickly mounting plate features anti-theft security and system, the Sunny Boy TL-US with Secure o adjusts to changes in solar irradiation, which makes hanging the inverter quick and easy.A Power Supply has you covered. Its wide mitigates the effects of shade and results in simplified DC wiring concept allows the DC range of power classes—from 3 to 7.7 kW— `9 higher total power output.And,with two MPP disconnect to be used as a wire raceway, offers customers the right size for virtually any trackers, the TL-US series can ably handle saving labor and materials. residential application.The TL-US series is not complex roofs with multiple orientations or only the smartest inverter on the planet,it's also 2 string lengths. The 380OTL-US and 770OTL-US models allow the most flexible. } installers to maximize system size and energy - An extended operating temperature range of production for customers with 100 A and 200 N -40 e F to+140 'F ensures power is produced A service panels. Toll Free+1 888 4 SMA USA www.SMA-America.com SMA America, LLC ® . ® ® . ® NELElU :;. QWt - AN at . ®. e S BENEFITSi rE, t Highest Efficiency i ° SunPower`""'Solar Panels are the most S E R I E S i efficient photovoltaic panels an the ' 1 I # market today. # 3 i More Power i .0urrpanels'produce more.power in § °the same amount of space—up to 50% ' I E ` mare than conventional designs and- =100% more than thin film solar panels. I Reduced Installation Cost -' - More power per panel means fewer i panels per insOL.This'saves both time I 1 and money ? I � Reliable and Robust Design x 1 The planet's most powerful solar panel. # ' -Proven materials, tempered front Mass, l The SunPowerrm 320 Solar Panel provides today's highest efficiency 1 rind a sturdy anodized frame allow i ' 1 � " i and performance. Utilizing 96 back-contact solar cells, the SunPower ' panel to operate reliably in multiple.. i $ mounting configurations 320 delivers a total panel conversion efficiency of 19.6%. The 320 ! 1 I panel's reduced voltage-temperature coefficient, anti-reflective glass and # exceptional low-light performance attributes provide outstanding energy i i delivery per peak power watt. I • SunPower's High Efficiency Advantage 1 20% 18% 19% ; $ * � 10/ 10% i 5%QuPy` % L- 0 �___�" .. ._._...�.,......._...a e' .w 1 ' Thin Film Conventional SunPower SunPower 1 i El Series E19 Series I, 3 t SPR-3.20E,WHT D = c UL us ' a '77 E 19 320 O ■ PANEL S U N PO, E' R' MAXIMUM EFFIC ® PERFORMANCE 9 1 Electrical Data IN Curve , "' { Meawred of Standard Test Condmoro ISTC)imadionce of 1000W/mr,AM 1 5,and m0 temperature 25°C 7 3LyW/m a4 A,C Peak Power(+5/-3%) Pmax 320 W 3 ` ) Efficiency, v 19 6% t000w/ma Rated Voltage —.._VmPp - — 54 7 V _ — e 4 Saflw/tn' g t I Rated Current Impp 5 86 A 3 — -- V 500 w/m* k Open Circuit Voltage Voc 64 8 V 2 - - a Short Circuit Current Isc 6 24 A 1 200w/m2 0 Maximum System Voltage UL 600 V 0 10 20 30 40 50 60 70 Temperature Coefficients Power(P) -0 38%/K Voltage M d • Voltage(Vac) -176 6mV/K Current/voltage characteristics with dependence on irradiance and module temperature Current(Isc) 3 5mA/K P Tested Operating Conditions € NOCT 45°C+/-2°C ' -- — - -- — f Temperature -40°F to+185°F(-40o C to+BY C) - - --- - t } Serres Fuse Rating 20A f• 1 13psf 550 kg/m2(5400 Pa),front(e g snow) I ) Max load — w/specified mounting configurations It Mechanical Data 50 psf 245 kg/m2(2400 Pa)front and back—e g ; s Solar Cells 96 SunPower all-back contact monocrystalline wind High transmission tempered glass with ° ! Front Glass � Impact Resistance Hall 1 in (25 mm)at 51 mph (23 m/s) i --- anti-reflective(AR)coating --- - -- - - Junction Box IP-65 rated with 3 bypass diodes 3 I Dimensions 32 x 155 x 128 (mm) Warranties-'and Certifications ) > Output Cables 1000mm length cables/MultiContact(MC4)connectors Warranties 25 year limited power warranty Frame Anodized aluminum alloy type 6063 10 year limited product warranty ( (black) t Weight 41 0 lbs(18 6 kg) Certifications Tested to UL 1703 Class C Fire Rating I 1 Dimensions I 3 I I Grounding Holes ) t 2X ,200 IIII 2X 262 .e724; 'moi ;1030_ 12 4,66—_ i �_—aY IK [ MM 2X 3C •••+^•� 2X 577 8 4 2 f, 4X J':' ) (IN) 1lflJ 227C1 ; - 17 - - - I?03-j " 4 I --r— 2X I 4 8 4 g[ I t° _ 2X"42 ` E 1046 ,17; 6X 1002 I 1 I ,41 18' 1 '3'i 45' 1• I I k 4 - t ! I ( � I � s '4Y, 312 —2X ?i5 i : 2X 2 1 i - - -6i 391 - .I j 12691 13602 til:;l ' 46 i ^_Y ;535 4X f 47 J r"`---- --- _60 45_ --- <_ i { i CAUTION: ;BEAD aAFE 7VAM)1P,1ST. LLATION INSTRJU,1014S E;ORE USNG THE PRODUG. � YES t sk'npow•_rCOrp Coir fel-de"ai;S f ' R } ? SUNPOWER and the SUNPOWER logo are trademarks or registered trademarks of SunPowerr Corporation m SunpowerCOrp.com t fitj C�December 2010 SunPower Corporation All nghis reserved Specdicatirm,included in this dntasheet are subject to change wthout notice Document 4001-65474 Rev**/LTR_EN -------------------------- NEW EQUIPMENT --------------------- ---� EXISTING SERVICE 120/240, 1 PH, 3W - I I 1 1200A KVi H PV—SA-1A e A g AC—COMBINER PANEL -- .. t A INV-1 AAC—CMBT3—12 1 (LOCATED NEAR INVERTERS) It — AC DISCONNECT(PV LOADS ONLY) --AC—DSC-1 N INTEGRAL DC/AC DISCONNECT SWITCH PV—SA-1B SKR-1 J r I; '• —� �MAIN PV—SA-2A FUSED INV-2 I I j I 2 1 1 13xR-2 N ® 4 ON • •• Z 1 INTEGRAL DC/AC j ( j I N I © ® <a DISCONNECT SWITCH I I I N13 I I I PV—SA-2B j I I C j EGC I ( i -- _ ___ __________ _ __ GEC I EXISTING �— — J__.--,—_ #6 Cud--,-----IGEC I GEC 7--WIRING GUTTER i , �— IRREVERSIBLE SPLICE —� EXISTING AC PANEL PROPOSED 3-LINE ELECTRICAL DIAGRAM Arda Haratunian REVISIONS c/o: North Fork Wood Works 1250 SOUndvleW Ave, Ext ENERGY ELIMINATING THE COST GE ENERGY Southold, NY 11971 1 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 2 Drawing No: HRTNAN-3LD1 Revision: 1 Revised: 11/08/2016 EQUIPMENT&COMPONENT SCHEDULE CONDUCTOR SCHEDULE TAG DESCRIPTION SPECIFICATION TAG TYPE, CONDUIT AWG./ PV-SA-1A PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-E19-320, 1-STRING OF 7-MODULES EGC A USE-2/PV, PVC-40-1" 10 / 6 PV-SA-1B PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-E19-320, 2-STRINGS OF 7-MODULES B THWN-2, PVC-40-1" 10 / 6 PV-SA-2A PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E19-320, 2-STRINGS OF 5-MODULES C THWN-2, PVC-40-1-1/2" 4 / 6 PV-SA-2B PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-E19-320, 2-STRINGS OF 6-MODULES D THWN-2, EMT-1-1/2" 2 / 6 1.)CONDUCTOR TYPES AND SIZES TO BE AD- INV-1 INVERTER, DC/AC SMA INVERTER, MODEL: SB7000TL-US-22,240V JUSTED FOR TEMPERATURE, DISTANCE, BUN- INV-2 INVERTER, DC/AC SMA INVERTER, MODEL: SB7000TL-US-22,240V DLING AND DERATING FACTORS. AC-CMB-1 AC COMBINER PANEL - 250V, 100A,NEMA-1, 1-PH,3-WIRE 2.) ELECTRICAL CONDUIT TO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. BKR-1 CIRCUIT BREAKER, INVERTER MATCH AC-COMBINER PANEL BRAND, 2-POLE,30A BKR-2 CIRCUIT BREAKER, INVERTER MATCH AC-COMBINER PANEL BRAND, 2-POLE,30A 3.) ALL ELECTRICAL MATERIALS AND INSTALLA- TION METHODS TO COMPLY WITH NEC AND LO- AC-DSC-1 AC DISCONNECT, FUSED 250V, 100A,NEMA-1, FUSED;' FUSE RATING:70A CAL CODE REQUIREMENTS. ELECTRICAL LOAD SUMMARY DC CIRCUITS ELECTRICAL LOAD SUMMARY TAG OP.CURRENT OP.VOLTAGE MAX.VOLTS S.S.C. AC CIRCUITS @STC @STC @ T-MIN _ @STC TAG POWER VOLTAGE MAX.AC MAX. DC PV-SA-1A 5.86 A DC 315 V DC 510 V DC 6.24 A DC RANGE CURRENT CURRENT PV-SA-1B 11.72 A DC 315 V DC 510 V DC 12.48 A DC PV-SA-2A 11.72 A DC 274 V DC 324 V DC 12.48 A DC INV-1 7000 WATTS 211-264 VAC 29.2 A AC 30 A DC PV-SA-2B 11.72 A DC 328 V DC 389 V DC 12.48 A DC INV-2 7000 WATTS 211-264 VAC 29.2 A AC 30 A DC PROPOSED EQUIPMENT SPECIFICATIONS Arda Haratunian REVISIONS CO c/o: North Fork Wood Works GREEINILOGM 1250 Soundview Ave, Ext ENERGY ELIMINATING THE C05# OFENERGY Southold, NY 11971 1 1.) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 2 Drawing No: HRTNAN-3LD1 Revision: 1 Revised: 11/08/2016