Loading...
HomeMy WebLinkAbout28350-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-29153 Date: 12/26/02 THIS CERTIFIES that the building NEW DWELLING Location of Property: 165 SOUTH ST SOUTHOLD (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No. 473889 Section 70 Block 10 Lot 6 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated APRIL 30, 2002 pursuant to which Building Permit No. 28350-Z dated MAY 2, 2002 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is SINGLE FAMILY DWELLING WITH ATTACHED TWO CAR GARAGE AND COVERED FRONT PORCH AS APPLIED FOR. The certificate is issued to MANZI HOMES INC (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R10-00-0239 11/27/02 ELECTRICAL CERTIFICATE NO. PENDING 12/12/02 PLUMBERS CERTIFICATION DATED .12/16/02 WILLIAM SCHWARB 1"7�- 1>11pelcIrIz Signature Rev. 1/81 BUILDING DEPARTMENT TOWN HALL 765-1802 _ j APPLICATION FOR CERTIFICATE OF OCCUPANCY- 1 8 A. This application must be filled in by typewriter OR ink and submitted to the buildir inspector with the following: for new building or new use: ` 1 . Final survey of property with accurate location of all buildings, property line" streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form) 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildi and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to, April 9, 1957) non-conforming uses, or buildings a '.'pre-existing" land uses: 1 . Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and a consent to inspect signed by the applican If a Certificate of Occupancy is denied, the Building Inspector ,shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00. Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Buildine - $100.00 3. Copy of Certificate of Occupancy - .25V. 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date . . .�a. .l 6 • O . . . . . . . . . . . . . . . . . . . . . New Construction. . . '. . . . . . Old Or Pre-existing Building. . . . . . . . . . . . . . . . . Location of Property. . . 6S . . . .5C)c- � h S+re eT. . . . . . . . . . . . . . . . . ..Sb,_k�-101. . . . . . . House No. Street Hamlet Onwer or Owners of Property. . . . 1 G` Z . . . . .. .. . . . . S. . .f.' �. . . . . . . . . County Tax Map No 1000, Section. . . . C1. . . . .Block. . . . . 1 0. . . .. . . .Lot. . . . . . . . . . . . . . . . Subdivision. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . .Filed Map. . . . . . . . . . . .Lot. . . . . . . . . . . . . . . . . . Permit No. ;R.P.35C). . . . .Date Of Permit. 4iJ Q.;) . . . . . .Applicant.MAI)?.3. . . . . . Health Dept. Approval. . . . . . . .\4:1.5. . . . . . . . . . . . .Underwriters Approval. . . . . . . . . . . . . . . . . . . . . Planning Board Approval. . . . . . . . . . . . . . . . . . . . . . . . / Request for: Temporary Certificate. . . . . . . . . . . Final Certicate. . .! . . . . . . . Fee Submitted: $. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . : . �:v . ."/. .`-^:.4 . . C . . . . . . . . . . . . . . . . APPLICANT 6X Com x9153 V 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 r5 BUREAU OF ELECTRICITY 5 40 FULTON STREET -- NEW YORK, NY 10038 5 CERTIFIES THAT 5 Upon the application of upon premises owned by 5 5 FULTON ELECTRIC INC. * MANZI HOMES INC 5 5 77-7 WINDSOR PLACE 165 SOUTH ST ISLANDIA, NY 11722, SOUTHOLD, NY 11971 5 5 Located at 165 SOUTH ST SOUTHOLD, NY 11971 5 5 Application Number: 1067076 Certificate Number: 1067076 5 5 5 Section: 70 Block: 10 Lot: 69 Building Permit: BDC: NS11 5 28350 5 5 Described as a Residential occupancy,wherein the premises electrical system consisting of 5 electrical devices and wiring, described below, located in/on the premises at: 5 5 Basement,First Floor,Attached Garage,Outside,Attic, 5 5 5 was inspected in accordance with the National Electrical Code and the detail of the installation, as set forth below,was 5 rj found to be in compliance therewith on the 13th Day of December,2002. S 5 Name QTY Rate Ratine Circuit Type 5 5 rj Alarm and Emergency Equipment 5 Sensor 1 0 Carbon Monoxide 5 rj Sensor 4 0 Smoke 5 5 Appliances and Accessories 5 5 Dish Washer 1 0 1.2 KW Cfj Furnace 1 0 Oil C� 5 5 Pump/Motor 1 0 1 H.P. 5 Wiring and Devices 5 Receptacle 25 0 General Purpose S 5 rj Switch 25 0 General Purpose 5 Fixture 24 0 Incandescent 5 5 Receptacle 2 0 20 amp Laundry X75 5 Receptacle 9 0 GFCI 5 Service 5 5 1 Phase 3W Service Rating 200 Amperes C, 5 Service Disconnect: 1 200 cb 5 5 Meters: 1 seal 5 5 5 1 of I 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 5 O rJ ar��nr�rJ�rJ�r�`nrJrJ�c rrJrJrJ�cnrJcPrJ�r�r��l arJrsrJ arJrJ�r nrJ�rJ��n�nrJ�cnrlrJ�rJ��lrJ��nr�rJ��l a rJ��l acnrJrJ�lrJr rcncPc nr��nr rr��l arJ�rJ�l-a o o�g�FFO(��OG a Town Hall,53095 Main Road y Z Fax(516)765-1823 P. O. Box 1179 • Telephone (516)765-1802 Southold, New Yod11971 OFFICE OF THE BUILDING INSPECTOR TOWN OF SOUTHOLD C E R T I F I C A T I O N DATE: 16 - C)a Building Permit No. , I��� 3JG owner: r ') O�Yl Z`i H-a e-vl e S I ►'l C (please printf) Plumber: please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. u\ (Plumber ignature) Sworn to before me this day of Vec, �?00'� Notary Public, SC1 County R3SALIE SALEMME NOTARY PLOLIC,State of New York 01SA4800818 IIuaGCied in Suffok Cast.�,,� Commissbn Expires January 31_(�::.� _ .. —>:�.>.ter--�.T---,--.�•_ —.,.,,...,-.- ��:......--,.--.-.-......_..�.----��--,.-n,���_�, __�-,�-:-, _._--�_<� The New York Board of Fire Underwriters Bureau of Electricity is in the process of issuing a certificate of compliance for the electrical installation as provided for in the application for inspection New York Board of Fire Underwriters Bureau of Electricity Inspection activity pursuant to Application has been completed and a certificate of compliance setting forth the detail of the electrical system is being prepared. i� r3�az� Inspector ate TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET VILLAGE DIST. SUB. LOT RAOR OWNER 4 v'(/ /cM to/ Ch N E ACR. e a V1 0 1v .3 S W TYPE OF BUILDING RES. SEAS. VL. FARM comm. CB. MICS. Mkt. Value LAND IMP. TOTAL DATE REMARKS 7 z- 02 15 12 51q9 a /) Ikea I AGE BUILDING CONDITION NEW NORMAL BELOW ABOVE FARM Acre Value Per Value Acre Tillable FRONTAGE ON WATER Woodland FRONTAGE ON ROAD Meadowland DEPTH House Plot BULKHEAD Total DOCK STATE OF NEW YORK ) ss: COUNTY OF SUFFOLK ) -7- 666�le j.. &rem being duly sworn, deposes and says: That deponent is over the age of 18 years and resides at That on theme day of A„P.Z; L,_ , 20qf;�deponent architect/engineer, licensed by the State of New York, hereby states that s/he accepts full responsibility for the accompanying plans compliance with the New York State Fire Prevention and Building Code (9 NYCRR); said plans pertain to property located at SCTM# 1000- 0.70 - 1O — 00 6 street address 16-5 6ot0ch SAfrei- A I IVEngineer Sworn to before me this 2 Cday of APc i7t� STEVEN E. LOSQUADRO Notary Public Notary Public, State of New York Reg. No.20L05076843 Qualified In Suffolk County Commission Expires April 28s cc: Applicant Town Of Southold P.O Box 1179 Southold, NY 11971 * * * RECEIPT * * * Date: 12/18/02 Receipt#: 15847 Transaction(s): Subtotal 1 Septic Permit- Operation - Resid. $10.00 Check#: 15847 Total Paid: $10.00 Name: Manzi, Homes Inc P O Box 702 Rocky Point, NY 11778 Clerk ID: BONNIED Internal ID:64831 Town Of Southold P.O Box 1179 Southold, NY 11971 * * * RECEIPT * * Date: 04/25/02 Receipt#: 13702 Transaction(s): Subtotal 1 Septic Permit- Construct- Resid. $10.00 Check#: 13702 Total Paid: $10.00 ID Name: Manzi, Homes Inc Pob 702 Rocky Point, NY 11778 Clerk ID: LINDAC Internal ID:53466 13- U 1_I1 -1- ��- Applicants Date Owners Name: ✓� �Y�� ---- Reviewed: S / DL Architect/ (,,, Date Engineer: - kr -- Submitted: 0"2.-. SCTNI M: Distrix: 1 ,000 Scch on: 70 Block: w_ project t/// ,(J �Q Subdivision Location: 6 6 5- SD`s 1r!ti_ at _w^�` _ Single &, separate Required ccrtiFIC aIioil SYes /No ,- ----__-----_ -- ---.___— Req. Req, d, /olimp DismoRN(O IIAI size AcuiaC 7 tlAl coverage Prop ctf- ------- "7`� Rcq. r!a/ r 1 Req. - �{� It'tonYard Proposed: ) (Side Yard _ Proposed. a I (Real Yard Project Description: 6J/b( 4 GA,,_ < o 44g AGENCh' E RMITS Permit . REQUIRED FOR REVIEW NSA. NO YES Number A/1'3,- Suffolk County Health Dept. _ AQ >, 3p New York State D. E. C. •z Town Trustees z Town Zoning Board approval: r/ Town Planning Board approval: Flood Plane Elevation ??? y Flood Zone: 765-1802 BUILDING DEPT. INSPECTION [ 64 FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: z �z DATE INSPECTOR DO VD M-1802 BUILDING DEPT. INSPECTION [ ] F NDATION IST [ ] ROUGH PLBG. [ FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE /& CHIMNEY REMARKS: t DATE 4--7 1/ INSPECTOR 17/ 765-1802 BUILDING DEPT. INSPECTIO [ ] FOUNDATIO T PLBG. [ ] FOUN ION 2ND [ ] INSULATION [ RAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY RE 5 l 2'� DATE INSPECTOR 9F354- M-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ) UGH PLBG. [ ) F DATION 2ND INSULATION [ FRAMING FINAL [ ] FIREPLACE & CHIMNEY REMARKS• DATE /7 :;!� INSPECTO T65-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INS ION [ ] FRAMING [ FINAL [ ] FIREPLACE & CHIMNEY REMARKS: d7 C V t DATE 1/INSPECTOR 1 / FIELD INSPECTION REPORT DATE COMMENTS op b � 7 FOUNDATION (1ST) l � -------------------------------------- 7 FOUNDATION(2ND) z _ o 4 ROUGH FRAMING& m PLUMBING _ Y r INSULATION PER N.Y. STATE ENERGY CODE - 20 FINAL ADDITIONAL COMMENTS C - --- - — - -- - N - --- - - O m 1 � . y � b ?. State existing use and occupancy of premises and intended use and occupancy of proposed GOIj6tNQt1011; a. Existing use and occupancy 0 GCG C`T a -1 b. Intended use and occupancy ('} ►) -4i� e-)", ( � Te.S,CL e r,e e >. Nature of work (check which applicable): New Building r� Addition _Alteration Repair Removal Demolition Other Work (Description) t. Estimated Cost �� © 0a x Fee (to be paid on filing this application) If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars If business, commercial or mixed occupancy, specify nature and extent of each type of use. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories Dimensions of entire new construction: Front .5 k Rear—O ' earb 7 ' Y " Depth Height Number of Stories I Size of lot: Front `� S Rear 6 Depth S 3 0'> 0. Date o f Purchase - 7, Qtr 00 Name of Former Owner P-)a rpt 2 I i C I. Zone or use district in which premises are situated 2. Does proposed construction violate any zoning law, ordinance or regulation: /10 3. Will lot be re-graded Will excess fill be removed from premises: YES NO 4. Names of Owner of remises ti1Gr�z; l-}o�,er Address�-D GOA- >o \.- P-0-Phone No. 63, LICI _ 103 9 Name of Architect ��ntT Q.ti�le r Address i:o Go t. f 3y 3h&e-4 hone No Fa 1. �-Fj-o Name of Contractor VACni) Address Ro 3ok Toa 1 Pr Phone No. '`7�lq- /O 3.� 5. Is this property within 100 feet of a tidal wetland? *YES NOi • IF YES, SOUTHOLD TOWN TRUSTEES PERMITS MAY BE REQUIRED 6. Provide survey, to scale, with accurate foundation plan and distances to property lines. 7. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. TATE OF NEW YORK) SS: 'OUNTY OF �Qr�i1 CZv.iC�O being duly swom, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, i)He is the 4e-�msiae.,T (Contractor, Agent, Corporate Officer, etc.) C said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; iat all statements contained in this application are true to the best of his knowledge and belief; and that the work will be erformed in the manner set forth in the application filed therewith. worn to before me this '6y day of rt 200'Z. N is Sign ture of Applicant TEVEN E.'LO-SOUADRO Notary Public, State of New York Reg.No. 20L05076843 Clualified in Suffolk County Commission Expires April 28;;uw ELEVATIONS ARE IN ASSUMED DATUM. WELL WELL ED T0: I NO SURFACE WATER EVIDENT WITHIN 300 FEET CERTIFIED HOMES, INC. AREA: 17,850 S.F. = 0.410 AC. +i MANZSUNRISE ABSTRACT CORP. WELL & SEPTIC PER OTHERS o SANG SAN. SYS. LOCATED 1N �n FRONT YARD J EASEMENTS AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED 'h ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT ' LAND NOW OR FORM-.-RL LAND WOR FORMERLY 4 V Fi ti .] THE .7ME OF THE SURVEY EDWARD J. LADEMAN Jr. WALTER A and HELEN MOCN/SH ' O O Q GLARIN EES INDICATED HEREON SHALL RUN ONLY TO THE PERSON(S) FOR L" O ,7 W ( > WHOAI THE SURVEY LS PREPARED, AND ON HIS BEHALF TO THE TME COM- . . '. N 9 G. O PANY GOVERNMENTAL AGENCY AND LENDING INSM77ONS LISTED HEREON, 05AN. a ry z O x .Lw AND TO THE ASS/GHEES OF THE LENDING /NS7TT7/77ON. GUARANTEES ARE O i4 O en 0. NOT TRANSFERABLE TO ADDITIONAL INS77TU77ONS OR SUBSEOUEW OWNERS. � THE OFFSETS (OR OWENSIONS) SHOWN HEREON FROM THE STRUCTURES TO FENCE Z ¢ UJ F. Q THE?ROPERTY LINES ARE FOR A SPECIFIC PURPOSE AND USE AND THERE- 0.9 N N82*J7' 0"E 119. �N E LU ra p O V (L p FORE ARE NOT INTENDED TO CU/GE THE ER£CRON OF FENCES RETAIN/NC G A 0.3' W. _ O.B N. m W � �y O C4 O ro WALLS. POOLS, PATTOS, PLANTING AREAS, ADDITIONS TO BUILDINGS AND I d ('} L p\ (� tr] O ANY OTHER CONSTRUCTION. j I _ PIPE 4' CHAIN LINK NCE NC. MON. CQ a Q lV^7 '�.., !\- W Cr o z o O w Q pa JOB N0. F3118 W SAOC �. (.5V z It REIMSIONS: O S/7E PLAN 08/25/2000 6 Z CC l 703 - i OCL' w oG To/03/2000 /na^,o'>- I O w Q .4 � O k' tj ADD TEST HOLE 11/07/2000 ` W O C VACANT — WOODED y I Q V PL @ N 1•' LOC. ADJ. OWNERS WELL A A O 8 Jq c� w Q > c3 SAN-0 w . srs 11/8/2000 U Q CC 26 ��IN. / LO J Q Q REV. SAN. 11/16/2000 `1 '0 W W ti F, Q W 2 y 31' ����' '�� Liu Z =.• W LU Z v 3 C PRO �POS W U G o W o CC° 55.33' x 7.50' I C> U n A [c Cn W 3° C� DW ING/ 31=-I o 12p, 3 CCW �� o o & G a license no. 050149 o a z w 53 SURVEY OF Q ;� C� GAR. Co`p z Co w Q < DESCRIBED PROPERTY o C Q SANG Js N CC , N a J z ^ C /� I ^ 3 SITUATE AT QQ) C SOUTHOLD I Z CC / PROPOSED WELL. in TOWN OF SOUTHOLD MAINTAIN D MIN. O SUFFOLK COUNTY, NEW YORK FENCE C( SEPARATION FROM PIP EX1ST & PROP. SCALE 1"'=40' DATE. AUGUST 12, 2000 94.72 SANITARY 0.3' W. 0 SANTARAR Y SY57FM5. CONC. MON. ` Nn-10 S82037'10' 11 .00'EDGE OF PAKUEM :.c.r.M otsr l000 sec.070 euc 10 Loroos TEST HOLE 101.3 100.59 00.7g BY. -``=�00NAER . 2000 1K 101 / FL 100.82 G V O Q N9VEMBER 2, 20G0 O N C 0.27 kVA p DARK BROWN LOAM S UT STR ET —� BROWN LOAMY O 132 f hway SAND 2 Ha on Ba N.Y. 46 - (631) 8-5330 PALE BROWN FINE SAN. o e = L TO COARSE SAND IMPROVED, DWELLING 2 Mara E Charost LS Successors to 17',NO WATER S IMPROVED Pau/ T. Canaliz% LS Robert A Kart LS LL Good Ground Surveyors, P.C. ! " L 2CI? LAND NOW OR FORMERLY LANDbiz PERLY - EDWARD J. LADEMANN Jr. WALTER V. and HELEN MOcNISH N NE 0 N82@37'10"E 119.00' FENCE. 0.3' W. 1 PIPE CC 4' CHAIN LINK FENCE CONC. MON. j (` Z << . ' (r EDGE OF WOODS I O �lJ V V V V V V v V V v V V V Q1 L.V v v v v v v v v v v v v v � U v= Q � Z 20.6', I o 24.8'h � I W N CONCRETE 10.3' ? 3 c ��5 N FOUNDATION �D. 30.8' ,LU o 0 p 21.7' r. . 104.9 ^ O a Qo h =zz 2J.3' i� N 20.7' N S J z N I ^ � I Q) 0EX1SnNG WELL ((O O FENCE 94.72' 0.3' W. 0,2E E. CONC. MON. NYT-1O ' S82*J7'10'pW 119.00A EDGE OF PAVEMENT 101.38 100.59 100.1 (1101.45 FL l00.82 Er 100.21 SOUTH STREET 0 0 �a AREA: 17,850 S.F. = 0.410 AC. WELL & SEPTIC PER OTHERS CLEARED AREA: 13,4J4 S.F. = 75.3X CERTIFIED T0: MANZI HOMES, INC. SURVEY OF SUNRISE ABSTRACT CORP. DESCRIBED PROPERTY EASEMENTS AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED SITUATE AT ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT ,SOUTHOLD THE 77ME OF THE SURVEY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON(S) FOR TOWN OF SOUTHOLD WHOM THE SURVEY IS PREPARED, AND ON HIS BEHALF TO THE TIRE COM- SUFFOLK COUNTY, NEW YORK PANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTIONS LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INST7TU770N. GUARANTEES ARE NOT TRANSFERABLE TO ADDITIONAL INSTITUTIONS OR SUBSEQUENT OWNERS. SCALE: l --40' DATE: AUGUST 12, 2000 THE OFFSETS (OR DIMENSIONS) SHOWN HEREON FROM THE STRUCTURES TO THE PROPERTY LINES ARE FOR A SPECIFIC PURPOSE AND USE AND THERE- FORE ARE NOT INTENDED TO GUIDE THE ERECHON OF FENCES, RETAINING S.C.TM. DIST. 1000 SEC.070 BLK.10 LOT006 WALLS, POOLS PATIOS, PLAN77NG AREAS, ADD177ONS TO BUILDINGS AND ANY 07HER CONSTRUCTION. t. J08 NO. F3118 A'Fy, REVISIONS: E. ' y 511E PUN 06/25/2000 ............::.......... .:. y�:.:::...... 10/03/2000 LOC. TEST HOLE S1110712000& 107-4:.::. .... . h way Loc. AS OWNERS 000 O'e° �, SIN SYS. 11/8/2000 ..... ...:. . REV. SIM IV16/2000 '' 7a Ha on Ba N.Y. 46 REV. SAN SYS. 12/11/2000 r� �:� (631) 8-5330 R /7 WELL AND SIN. `�j<<0749 O0- STAKE WELL 06/27/2001 �Nd SUR0� Marc E. Charest, L.S. REV.. DWELLING 04/24/2002 Successors to STAKE PROP. HSE, SANITARY& Paul T. Conalizo, L.S. Robert A. Kart, L.S. WELL 05/20/2002 Good Ground Surveyors,UNDER CONSTRUCTION 06/27/2002 license no. 050149 Y ' P.C. LAND NOW OR FORMERLY LAND NOW OR FORMERLY EDWARD J. LADEMANN Jr. WALTER V. and HELEN MocNISH FENCE N82`37'1 0' 119.00' 0.9' N. FENCE 0.3' W 0.8' N. PIPE 4' CHAIN L/NK FENCE CONC. MON. z O Ld ��.� •� J J EDGE OF �'�' �' I `7 O C<EggjNC �, �� O p 2 O �� CP L �_ C W Q LAJ Q) 2 J (10.3 8.8 h (103.4) _;L-WI ST r�Di�C �lLAJ 14 24.7'h 20 i. ,� CC I ti o ONE STORY 06 3 FRAME DWELLlNG10'4 C6 rc 106.3 O G.F. 104.4 45.1' o cC O p 22.7 ,- C) l(] , (10z.8) __TJ2' oGAR' w N CONC. PORC 2010x.3 CC N J J p O �______5z" w cc I O 2 EXISTING WELL ® FENCE 2 o A CC 94.72' LU 0.3' W 0r2E E �' CC _ CONC. MON. NYT--10 582'37'10"W i 1 `00' EDGE OF PAVEMENT 101.38 100.59 70019 pp ¢1011..4®�5 0100.82 Er 70027 SO T@py9 STIP FEET p O O 2 �lIc; AREA: 17,850 S.F. = 0.410 AC. c')-4 ' WELL & SEPTIC PER OTHERS p CLEARED AREA: 11,689 S.F. = 65.5 ' ""z SURVEY OF FILE NO. 3118 CERTIFIED TO: DESCRIBED PROPERTY REVISIONS: MARY ANN GIAMBRONE � r� SITE PUN 08/25/2000 SUNRISE ABSTRACT CORP. to :z ADO TEST HOE 11/07/z00o BANK OF SMITHTOWN ^-! SITUATE AT `SAN.AS'S��8%2000` & to W SOUTHOLD REV. SAN. 11/16/2000 REV. SAN. SYS. 12/11/2000 TOWN OF SOUTHOLD REV. PROP WELL AND . PAT T SECCAFICO SUFFOLK COUNTY, NEW YORK ST E13WELOL006/27/2001 REV. DWELLING 04/24/2002 STAKE PROP. HSE, SANITARY& PROFESSIONAL LAND SURVEYOR P.C. CONSTRUCTION SCALE. 1"=40' DATE. AUGUST 12, 2000 WELL zo°z , UNDER CONSTRUCTION 06/27/2002 — f/NAL 11/01/2002 SUCCESSOR TO — S.C.T.M. DIST. 1000 SEC.070 BLK.10 LOT006 DONALD TASE, L.S. EASRICHARD WILHELM AND ASSOCIATES NOT GUARANTEED ANDD U SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE PROFESSIONAL LAND SURVEYORS NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF THE SURVEY. NF NORTHSTAR SURVEYING, P.C. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON(S) FOR WHOM ` j(/ PAUL T. CANAL/ZO, L.S., ROBERT A. KART, L.S. THE SURVEY IS PREPARED, AND ON HIS BEHALF TO THE TITLE COMPANY, v SE GOVERNMENTAL AGENCY AND LENDING INSTITUTIONS USED HEREON, AND TO THE ` GOOD GROUND SURVEYORS, P.C. ASSIGNEES OF THE LENDING INSTITUTION. GUARANTEES ARE NOT TRANSFERABLE TO '9 ADDITIONAL INSTITUTIONS OR SUBSEQUENT OWNERS. THE OFFSETS (OR DIMENSIONS) 107-4 W. Montauk Highway 328A Main Street SHOWN HEREON FROM THE STRUCTURES TO THE PROPERTY LINES ARE FOR A 1 * Hampton Bays, NY 11946 Center Moriches, NY 119J4 SPECIFIC PURPOSE AND USE AND THEREFORE ARE NOT INTENDED TO GUIDE THE ; ((PHONE. 631 728-5330 PHONE 631) 878-0120 ERECTION OF FENCES, RETAINING WALLS, POOLS, PATIOS, PLANTING AREAS, r ADDITIONS TO BUILDINGS AND ANY OTHER CONSTRUCTION. �� pQ FAX (631) 728-6707 FAX: (631) 878-7190 UNAUTHORIZED SECT70N7209 OFTHE NEW YORK STATE TEDUCATION RLAW.ICOPIES OFlTHIS SURVEY ~SFO JQ' N.Y.S. LIC. N0. 049287 MAP NOT BEARING THE LAND SURVEYORS SIGNATURE AND RED INK OR EMBOSSED NO 5 SEAL SHALL NOT BE CONSIDERED A TRUE VALID COPY. COPYRIGHT - 2002 PAT T. SECCAFICO P.L.S., P.C. - a- 35c�l Z O L 7 0 ASPHALT ROOF SHINGLES (TTP) 7 TOP OF PLATE --C ONT. I YL SOFFIT P.) c3 E3 VINYL SIDING LTYFFJ 6. off n m iiiRI F VINYL 51IDN6 (TYP) TOP OF FOUNDATION TOP OF SISPLCOR 'GRADE GRADE�t N 0' R14D x 47" DEEP 5" P.G. FND. WALL OR -0 UNDISTURBED ON &` X S` P.G. FTG. POI CONCRETE F WITH 4X4 CCA POST ---------------------------1, -- --------------------------------------- ANCHOR TO FTG. L_-i L_,: ------------------------------------------------------------------------------------------------- --- ------- -------- L TYPICAL ---LF___ a" P.C. PND. WALL F---I ON --- ON 161, X all P.C. FTG. STEP FTG 30 DES MAX -------------------- TOP OF -00711 -----------I L-----1___________________________________________________ ---- ------------------- ------------ L L__ --------F RIGHT SIDE ELEVATION FRONT ELEVATION X U_ ami F -4 Or Cq va 0) 5 PLUMBER CERTIFICATION if copper tubing Is used I'D )_ CINLEAD CONTENT BEFORE x for water distributing CERTIFICATE OF OCCUPANCY System piping shall be z 0 Of types K or L only SOLDER USED IN 141A 7-ER to 6 UNDERWRITERS CERTIFICATE 01 WOOD FRAME CHIMNEY SUPPLY SYSTEM CA 111NO T - REQUIRED 1E)VCEED 2110 of 1% LEAD LL _ _PROVIDE ANTI-'S0KftAND/0A Uj PLUMBING IIIIIIIIAMMILINONEED DEMI S TO PART. 91 D A Aqm EC ASPHAFT ROOF SHINGLES eTYP) __,W.y._STAjE-BUIL[ftNI! CODE. A- OVERINO I2 N 7 TOP OF -LATE -- - - -—-- CONT VINT'L F0 SOFFIT ! I P 2 JEFFREY T. 5UTLER, P,E, __IEJ LLJ 0 VINYL 510ING (TYP)_ z W SIDING (TYP) TO F Su C/) W CC , 6 7 EFLOOR -------- DN TOP OF FC GRADE U4 - L-I U` >- 6 0 Z IL--- ------- OPENINGS PROVIDE HR. FIRE L------------J L------------i PROVIDE E IN SF cr :[ 0 I I RATED SEPARATION TO 5" P.C. FIND. WALL EMERGENC ES APE AS : ----------------------------- ON X a" P.C. FTG, PART. 717.3 (f) (1) OF L-------------------------------- REQUIRED B, P RT. 714 OF '__I L L-- 5" P.C. IFNE), WALL NA CODE. < 0) --r 1 43 ON I&` X 0, P.C. PTG. N.Y. STATE B. IL IN CODE'E.1 0 STEP FTG BO DEG MAX APPROVED AS NOTED LULL DO NOT PROCEED WITH I TOP OF FOOTING DATE•_J� " B. .#_,�� ----------------------------------------------------------------------- -------------------------- ----------------------------------- ------ L--------L----I- -------I-------------------------------------------------------FRAMIj14Q:UNTIL'5URVEY0 L--------L---- --------I---------------------------------------------- 0 L--`----------------------------------------------------------------------- ---------------------------L----------------------------------- BY.. OF FOUNDATION LOCATION FEF` f"'*"_LQ NOTIFY BUILDING DEPARTMENT AT 0 A LEFT SIDE ELEVATION HAS BEEN APPROVED. 765-1802 9 AM TO 4 PM FOR THE REAR ELEVATION FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE OCCUPANCY OR 2. ROUGH - FRAMING & PLUMBING USE IS UNLAWFUL 1. INSULATION It FINALA- CONSTRUCTION MUST WITHOUT CERTIFICATE BE COMPLETE FOR C.O. OF OCCUPANCY ALL CONSTRUCTION S14ALL MEET L Z 0 r T, �JF �P N G OR LIJ `0 0 EL 0 PAGE : REVIEWED AND APPROVED ET PURCHAQTE CONSTRUCTION & ENER 3Y ES.—NOT RESPONSZLE- FOFI PIP )VIDISM REVIEWED AND APPROVED ET" E3UILDERPESiGN OR CONSTRUCTION ERRO IS A ARM ES AS 10 PAFT721.1 I N.Y.S SUILOING GUIDE. ' REVIEWED AND APPROVED BY PURCHASER: I' REVIEWED AND APPROVED BY BUILDER: SUMMARY OF TOTAL THERMAL RATING GENERAL NOTES: IF THE TOTAL THERMAL RATING 15 ZERO (0) OR GREATER, THE PROPOSED DESIGN FOR THE BUILDING ENVELOPE COMPLIES W/ , 1. All work shall be performed In accordance with all state, THE ENERGY CODE. / municipal, local zoning and building codes and ordinances -1,61TAL TABLE having jurisdiction and best standards of construction practice A. WALL ASSEMBLY AREA U-VALUE RATING USED The American Institute of Architects Conditions shall apply A1. NET WALLS 1440 .01 +14C 6-I to all work performed on this project. A2. GLAZING 122 .32 -10 6-1 2.The Contractor shall verify all conditions at the site Any 43. DOORS 63 .01 +5 6-1 " discrepancies must be brought to the attention of the Engineer prior to commencement of construction. The Contractor shall be SUBTOTAL -NER-AL RATING FOR SECTION A fAI+Az+A3) H35 responsible for corrections not reported once he has started work B. ROOF/CEILING A55EMBLY except for hidden job conditions 3. Contractor shall guarantee to the Owner that all materials and BI. ROOF/CEILING 1391 .046 0 6-3 equipment Incorporated in the work well be new, and that all work 132. SKYLIGHTS .42 6 3 will be of good quality,free from faults and defects for a period SUBTOTAL THERMAL RATING FOR SECTION E S13I+52) O of one year from the date of the final Certificate of Occupancy. 4.The Engineer shall not be responsible for the construction means, G. FLOOR ASSEMBLY methods,techniques,sequences or procedures, or for the safety CI. FLOOR I3el .046 O 6-3 precautions and programs in Connection with the work, and he C2. FOUNDATION WALL shall not be responsible for the contractors failure to carry out WALL PERIMETER o o FT , the work in accordance with the construction documents. The ABOVE GRADE EXPOSURE O O FT Engineer shall not be responsible for the acts or omissions by INSULATION DEPTH the contractor. No changes shall be made in the documents 24' 45" and/or the building as designed without the expressed written 54" FOOTING o 0 0 consent of the Engineer. 5.The contractor and all subcontractors shall maintain continuous PERIMETER R-VALUE w rc Insurance Coverage including statutory policies(Worker 03. SLAB EDGE INSULATION 0 O O 0 Compensation, etc.)and general liability in an mount not less that$5 million and automobile liability and damage SUBTOTAL THERMAL RATING FOR SECTION G (Cl+C2+C3) o coverage not less than $2 million. The Engineer shall be a named Insured on any and all policies. IOTA_ THERMAL RATING 135 O.K. 6. Provide 0 025"aluminum termite shields over fibrous ' Insulation at all perimeter sills. r 7.All wood In contact with concrete or masonry to be Wolmanized or pressure creosoted ,�- 8.A single station smoke detector alarm device shall be Installed in each bedroom, an all floors and shall be all Interconnected per code 9. All bathrooms without operable windows to be mechanically ventilated as per New York Slate Code. 10. Heating to be designed to provide 70 degrees F.with outdoor '' designed air-temperature of 0 degrees F. and 15 MPH wind. I- 10 10101 f / I1 11.All electrical work to be in accordance to the rules and (/ - regulations of the N.Y B.F.U.and a N.Y.B.F.U. certificate is 'SLI to be presented to the Owner at the completion of the job. 6'0" 6' 1" 12' 5" 12'4 ' 12. Plumbing installation to comply with State and Local codes and the sewage disposal system to meet Health Department standards. 13. Do not scale drawings. Use figure dimensions only ' 14. All work to conform to the rules and regulations of the New York Energy Conservation Construction Code. All glazed area to be double _ glazed and all exterior doors to have insulated cores. - A 15.The Insulation protection as Indicated on these plans exceeds the Code's minimum standards. k-------- 16. These drawings and specifications are Instruments of service and shall remain the property of the Engineer whether the project for o , ----- which ______•_ - which they are made is executed or not. They may not be used o on any other project except by written authorization of the Engineer. can ° 25'1 ° , _________ ___________ ______________________ ________ ________ _______ X -- ____ ___ GIRDER z • _- - _ FOUNDATION NOTES. ___o' ° I_�__________"______ _ _ _�_�__ M. __ ______________________ ______________________________ __ __i ! i ,, 1111' _ 1. 112"Anchor Bolts @ 8'1 O.0 Maximum / ; J uRNAGE , 1.1.L a: T 2. 8" Concrete Foundation Wall, T-0" High, 3000#Test , /Ir J BE fM POCKET 3 16"x e"Concrete Wall Footings, 3000#Test I `\ ,, I GR UT 501 r r 4. 2-1 %"x 1117/8'Microlam Built-Up Girder- Grout Beam Solid in Pocket --I 5. 24"x 24"x 12'Concrete Column Footings,3000#Test , m 6. 4"Concrete Floor Slab, 30011#Test with 6"x 6"#10 mesh and vapor barrier \� _ °' O C I I u NSC W 7. Damp proofing and at exterior foundation below grade ~. L-i J o w H 9 a v n) Ilii 8. Foundation wall to extend a minimum of 8"above finish grade. T q '• x9 Q v I' 9. Assumed soll bearing capacity, 2 ton per square foot, subject to inspection and verification 5'a" F c. G.UB X • 10.All footings to be earned down to undisturbed soil. OVER FURNACE a m _� I EXCAVATED CELLAR IL _ 4 Q W rp, 11. No footing shall be set higher or lower than a 30 degree angle from any other footing °° PER ab I CODE " G SLAB O '' - - til Z tlJ 12. Pour no concrete on frozen round or in freezing weather � Q , __ ___________________ 9 g 1 .. ON 4" POROUS FILL -' p q' P 13 3 112"lally columns. ; z D G i z L Q q) ' 4" O FSE , °i __ -----------------------i ,• re, MATERIAL NOTES: _ W I ty vp Floor V U- ILI- Nass rConstruction NJ 10C Cor _ - - 2_1_3/4'x - _ Irl _ _j --,�i 2-I }/4"x11 '/e" _,- 7 3 4' - _ - - _ _ r P.G. SLAB , 314" OSB plywood sub0oor, glued .; Lv J NaswrNJ lO floor joists,spacing as noted L , - (-- M.L7G 4 ' w 2-2x6 CCA 5111 with termite shield and sill seal. ! M.L. GIRDER M.L. G 11 v5' 2-I 3/4"xn v5' xn ve" Finish floors as Per agreement 2-I 3/4'xll VB `1.L. GIRDER �- - 2-I 3/4'xl; l/e' ON 4" , r IFI M,L. GIRDE - 3 M.L. IRDER IR ER I °1 POUROUS FILA --- �- , - ABEAM SOL ET PITCH To C.H.D. ENGINEER- Roof Construction: - J _- rt " -- BEAM POC E'� Asphalt CDXPIywood Sheathing r3-tab fl ri GONG xE' POURED ° '_____________________________ �tr'-'1➢_. n(4NFMr Shingles, y EL COLUMN GROUT SOLI 1S#Felt Paper 2x10 Ridge,structural ridge as noted ' �__ p TYP1cAL E FeonNG, uD .° , v 2x8 Roof Raftere@16'OC. as noted x@" _________________ _" m 2x6,2x8,2x10 Ceiling Joists @ 16"O.C. -` j 6 p .� _ POUR HAUNCH 2a" -- 2x8 2x4 Collar Ties @ 32"O.0 ° Wall Construction: ' ° a 4 , 2x6 Fascia,wrapped with aluminum Overhangas noted Vinyl full ented soffits Aluminum gutters and leaderso O a °° ' JEFFREY UTLEPR P. Vinyl siding II Tyvek Housewrap , 1 ry 112"CDX sheathing °• ' - -- - �u '' W C, 2x4 Gypsmboard C.with 2x4 shoe and double 2x4 plate L------------------------ ---------- --------- --- ----T ---_ ___--_-- - - -- - J °! r' Z O W ail X in ULI are W2"Mwsmanufatured byAlslde,verify all rough openings ------_______ ____________ ________ _ __ _______________________________ -------__--------------------------______s ____ _______ UNE ON4'FOUR GARAGE p A ❑ N 0 • 2x5 CGA w/ ?x2 GGA LEDGER, BOL' Q Il At least one window in each room shall comply with exit requirements - , PIrcH To C.H.D. W Q 0 Insulation: 12" RND x 47' DEEP, _'9'a" U �° ,� 11J ii 1 4"I.R-13 in all exterior Walls common with living areas and living areas common with garage POURED CONCRETE PIER W U LU F Q I n n to 6" R-19 in cathedral ceilings IOR To UNDISTURBED 5011-) Z y - Z Q' Z r 6' 'R-19 in all flat ceilings 11T 6.6 GOA POST x ° ) Ll Q y 4" R-11 In ail exterior garage walls ANCHOR TO F OTING, _ ,--,]2x10 aL. PORCH GIRD _ _v_ _ __•_ � S ---- ----1 Y TYPICAL ` __ __ _ ___ , , f J • FOUNDATION PLAN _- - ' m � o °o FRAMING NOTES. � ' LINE of PORCH AaovG"� ' ' i � O F (3 i 1. All headers 2x12 unless noted. / I °' �, 2. All comers are solid SMOKE DETECTOR S. Provide Bresu under in all walls N.Y.S. Code INTERCONNECT PER CODE \_/; 1 G 7 7 7 7 :1 - -_ -__ - _- DROP FNc-TO GAR FL-LEVEL - il 3. Double acks over 48"s ons d)4. Double joists under all parallel panitions -•JER1Fr_m_0.__------ Lli PP 9 ___ __________ ___ ___ 6. Rafter heel cuts shall not exceed 4". _ _ 7. Where joists are notched to headers so as to reduce beam depth, use bridle eons or metal connectors _ __ _ _ _ _ c 8. All floor joists,rafters and ceiling beams to be Hem fir number two or better construction grade with a minimum fb = 1200 p.s.I. O LL _ 9. All 2x4 and 2x6 partition walls to be Doug fir number two or better construction grade with a minimum fb= 1200 p.si ---_�_-�_- -_-_---_-- d 0 0 10. All beams and girders shall have 2"bearing min 3 - r AEL - - JS' u" 20. 8- l�I FAGEN: 65' a" � 'I�'I 1X1 RIDGE 2X5 RAFTERS REVIEWED AND APPROVED BY PURCHASER: 1/2' ODX SHEATHING 15+ FELT REVIEWED AND APPROVED BY BUILDER: ASPHALT ROOF SHINGLES CONT RIDGE VENT -IS INSULATION � m 1/2" GWB X12 I R-19 INSULATION 11 g TOP OF PLATE— I/2° GWB 1'4" OH CONT. VINYL SOFFIT (TYF.) T' GWB m 0 2X4 STUDS DINING ROOM - LIVING ROOM + R-13 INSULAT'ON 1/2" COX SHEATHING TYVEK HOU6EWRAP VINYL SIDING m 3/4" 3UBFLOOR 0 TOP OF eueFLonF: — I— . s • TOP OF FOUNDATION— —- -IS IN5Up 1X6 GGA m - 12" FIND X 42" DEEP H GRADE Z O (OR TO UNDISTURBED SOIL) AWAY FOUNDATION FROM L • m POURED CONCRETE FTG FOUNDATION WITH 4X4 GGA POST 2-2X6 GGA SILL CELLAR V 3/4" X II 7/8" M.L. HDR TYPGICAL HOR TP FTG. 0 1/2" ANCHOR BOLTS WITH 3 1/2" STEEL COL. fu 6. SILL SEAL ON F.G. FTG. ' TERMITE SHIELD p 9 8" GONG. FOUNDATION m B"X16" GONG FTG it DAMPROOF BELOW GRAD. 4" SLAB n7" 8' m TOP OF FOOTING - I _ 1 N' a" I SECTION A-A 11 lO" 618" h.. 1, lO" h, IO.. 5' o 7, 7'. 3' 2" 3. 2., V2 2. T,. i 4" VTR 4" VTR r — — — — — — — — — — — — — — I 1031 I x W.G. W 0 1846 �F.1B46-L 2 -• UPSET MASTER DR H L _ _1 - 1856 -_ -` 2BS6 ' :856_ __ . 1856--:� q N y LL 11 3 , 61ryK I _____' I Al ° `__1______ �-L- -.{-�. ➢I W r __ V D.W. 1 ft U 1° o i _ /' l _ 1 DINING ROOM rN �I W.G Tb'HER 1 g CATH. GLC. o S n W.C.1WB r-- 'm ' SHOWER F1 y -2. 0' 6 li r______ r______ I L v L 1 - -_ - MAIN FLOOR O O 3' S G.LTO AN APPROVED II - .- B e UI' 4" ' C.O. G'O" 4f,{NITARY SEPTIC SYSTEM 1 O • TER BEDROOM T S 0. • ° 1 e1 �Q X } O 2' U U _ I � 1 _ MAS �y 9 S 'O" CLG. HGT. K 1 LL iw u i� - _-F' X FRAME WALL TO R.R 111 3 W.LC. m m KITCHEN w ' 30x72 1� 30x72 '� L _ - _ _ _ _ _ _ , z 0 Ig HOUSE RTRAP o U ,x, ,L 8'O "� ..L6. HGT. m � ✓ENTED im mi VENTED,m GLASS 10p Opi GLASS IOp 1 LH 111 SKYJTE: SKYLITEI _ — FLUMBING RISER DIAGRAM (NTS) 1 RE . -S. O4, h, 8. iT. B. " T DNT I1 IX � EXT j 4_ ) U T 0 BEARING WALL 7' 0' �' ° =4 ' e W —_— —_ —_ — —._ — STEA$ O _. .J-� OmI3/4POST ABOVE DR 4" X-11DR I— -- HDR d_(x.1 STEP , U z I » INS A4_u-_ UTILITY ME 2X10 RIDGE - o 111d" P.G. SLA ENCIINRFERROOF RAFTE4o- a °' r,mI'VEl'V Ir_ U a \agV- ryTO RIDGE POST _ _ _ _ _ _ _ _ _ _ _ _ _ _ s. - W 1 w I _ � `y HURRICANE CLIP NAILED im POCKET T 6" 1' 8" 3 ; 0 n `�"� TO RAFTER ° PLATE '° 3 I 1-2XIO HDR. - Q I LIVING ROOM cy / 1 (D2"x4" TOP PLATES I LN. ^- E. O N p O BO" CLG, HGT. C F1 .,-, U v 0 191 814 • y - 0x45 Q= Z K 'J 3 —° BEDROOM °7 V NTEDif'Y U �' • ° A65 c0 m JEFFREY T, BUTLER, P.E. 0'O" CLG. NGT. _ 1J 15' T" 4" I Q•, U 3 SK LITE:O A. O,. - a h 3 / 2 GAR GARAGE I 0 5/8" F.C. GLIB ON LA-LS U.I J 1 CL - Q % / AND CEILING PER CODE () HURRICANE CLIP DETAIL / z b lY 4" P.G. SLAB y TUB/SHOWEr� �1 �, .3 — -�� I Q O , " N 2856 2656 2856 2856 B56 ✓ 0 O s1 W I z L _ _ _ _ _ _ _ _ _ _ _ _ _ ._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ , COVERED PORCH Iti u w u /• ,.I 1 W 0 3 0 RAISE BOTTOn - ' OF GLCSET AS S/4"xb" GGA DECKING IK p U W w Z � Z r I ' REQUIRED FOR 1 ," 4 • H SHINGLE RIDGE CAP RIDGE `/ENT HEADROOM BELOW 1 / , � L� O FIRST FLOOR PLAN G B.J PGRG GIRCER — 1x1 G.), 4 16" ° 0] Fa- 0 0 MAIN LIVING AREA = 1224 SQ. Cm 6 o-e AT nl < = O -- - - - - - - -- - -- - - c _ F'1', 1 EP EXHAUST AIR L _ _ _ _ _ _ _ _ _ _ _ _ -� D SPAk I6 ¢ Q ST � "' HANG FR M R _ El SHINGLES GARAfsE AREA = 430 SQ.FT, -w- ' 0 1 2^B„R:� "B R R. / 5 10 O FELT PAPER ROOF SHEATHING (TYP.) LAUNDRY AREA = 90 SQ.FT, � 1 ° O.a I [� � F- COVERED PORCH AREA 12Co SQ.GT, LI U _ - 2-1 3/ ".dl lA8' M.L. LIDIR N i' SMOKE DETECTOR RAFTER INTERCONNECI” PER CODE L - - - _ - - - - - _ = - - _ - L" O.H.c - - _ _ _ _ _ _ _ _ _ CL 3' 10., 8' IO14' 8" ill' 1" 7, 7. 10' 4' IU' 1' RIDGE BEAM 45' ()' '0 8 A G E RIDGE VENT DETAIL bS. N. 1 • 1� 1Z 1.L 0 ASPHALT ROOF SHINGLE5 TOP OF PLATE O" y DONT.T. I YL i a ® ® SOFFIT IT rP.) - o w VINYL SIDING (TYP) TOP OF WEIILOOR GRADE VINYL SIDING (TYP) U — — - TOP OF FOUNDATION GRADE i n 8" P.G. FND. WALL I ' O ON 16" X 5" P.G. FTG. £ r i ' _ I r _____________________ r_______ __________ — r'____ _______________________________________ L, , 8" P.C. FND. WALL .r__________________________________J m L______________________________ _______ __________ __F___I r • ON 16" x 5" P.C. FTG. STEP FTG F---I � I r r--4-� 30 DEG MAX F---I __ TOP OF FOOTING F_- _ }________________________._-________I L 1 -L FRONT ELEVATION RIGHT SIDE ELEVATION ' W Q LL W Wim ::3 mum } X o ~ w0 mzm W 4 ro WOOD FRAME CHIMNEY (L ry, n L WITH VINYL SIDING L11 12 w ENGINEER: ASPHALT ROOF SHINGLES (TYP) ' � 1 ,�dNoissa�oy'�a I 12 �O �6gtLO '[% a 5 ) roP of PLarE � a 'F � d ® 3N B 1 DONT, VI L SOFFIT ( P.) LJEFFREY T. BUTLER, P.E. W El El U Os VINYL SIDING (TYP) W M VINYL SIDING (TYP) Q TOP OF SUBFLOOR U) O o O TOP OF FOUNDATION GRADE LU W Lu } H z O (D Q O I , � I ' ' 1 1 8" P.C. FN ON 16 X 8 P G FTG , I rL____________________________rL---I r D WALL Q] � Q L_____________________________L___r.L__� — L B" P.G. FND. WALL Q L-- -- ON I6" X eL P.G. FTG. L rL STEP FTG 30 DEG MAX L--rL--, ' I I O LL r TOP OF FOOTING N ________________________________ __________ _________.._r__________________________-______________________ 0_r____.� — _ — _ LEFT SIDE ELEVATION " 'I a z l REAR ELEVATION _ i�iru , 6 2002 2 , FAGE I, j REVIEWED AND APPROVED BY PURCHASER REVIEWED AND APPROVED BY BUILDER: REVIEWED AND APPROVED BY PURCHASER: REVIEWED AND APPROVED BY BUILDER: SUMMARY OF TOTAL THERMAL RATING IF THE TOTAL THERMAL RATING IS ZERO (0) OR GREATER, THE GENERAL NOTES: PROPOSED DESIGN FOR THE BUILDING ENVELOPE COMPLIES W/ 1.All work shall be performed in accordance with all stale, THE ENERGY CODE. municipal, local zoning and building codes and ordinances THERMAL TABLE having jurisdiction and best standards of construction practice. A. WALL ASSEMBLT AREA U-VALUE RATING USED The American Institute of Architects Conditions shall apply AI. NET WALLS 1440 .p1 dao 6-1 to all work performed on this project. A2. GLAZING 122 .32 -10 6-1 2, The Contractor shall verify all conditions at the site. Any A3. DOORS 63 .01 +5 6-I discrepancies must be brought to the attention of the Engineer prior to commencement of construction. The Contractor shall be SUBTOTAL THERMAL RATING FOR SECTION A lALA1+A3J •135 responsible for corrections not reported once he has started work B. ROOF/CEILING ASSEMBLY except for hidden jab conditions. 3. Contractor shall guarantee to the Owner that all materials and BI. ROOF/CEILING 1391 .1 46 O 6-3 Prnummnnt inrnrnnratPd m iha��yy// hi� r I�P �i i, t II i. B2. SKTLIGHTS x.42 6-3 c4 faults ,and cle a is for a period will ue new, a D will be of good quality, free from faults and de ects for a period SJBTOTAL THERMAL RATING FOR SECTION B /BI+BL of one year from the dale of the final Certificate of Occupancy. 4. The Engineer shall not be responsible for the construction means, C. FLOOR ASSEMBLY methods,techniques,sequences or procedures, or for the safety CI. FLOOR 1391 .046 O 6-3 precautions and programs in connection with the work, and he C2. FOUNDATION WALL shall not be responsible for the contractors failure to carry out WALL PERIMETER O O FT the work in accordance with the construction documents The ABOvE GRADE EXPOSURE O O FT Engineer shall not be responsible for the acts or omissions by INSULATION DEPTH the contractor. No changes shall be made in the documents 2a" 46" and/or the building as designed without the expressed written e4" FOOTING O o 07. consent of the Engineer. ,-Oo 5.The contractor and all subcontractors shall maintain continuousla PERIMETER R-VALUE Insurance coverage Including statute golicies(Worker y G3. SLAB EDGE INSULATION O O O O�" � Compensation, etc.)and g6nerM9Iiyl, m�� sa less that$5 million and automobile liability and damage SUBTOTAL THERMAL RATING FOR SECTION G tCl•G?•G31 O coverage not less than$2 million The Engineer shall be a named insured on any and all policies. TOTAL THERMAL RATING + 135 O.K. 6. Provide 0.025"aluminum termite shields over fibrous insulation at all perimeter sills 7 All wood In contact with concrete or masonry to be Wernanized 67' d" or pressure creosoted 8 A single station smoke detector alarm device shall be installed ` u In each bedroom, on all floors and shall be all interconnected per code 9. All bathrooms without operable windows to be mechanically ventilated In as per New York State Code. i 10. Heating to be designed to provide 70 degrees F with outdoor 14' I" 8' 6" '4' a" 111, -i" designed air-temperature of 0 degrees F. and 15 MPH wind 1 11. All electrical work to be In accordance to the rules and regulations of the N.Y.B.F.U. and a N Y B.F.U. certificate is to be presented to the Owner at the completion of the jab 8,10" 6' 1" 12' 5' 12' 4" C 12. Plumbing Installation to comply with Stale and Local codes and the sewage disposal system to meet Health Department standards. 13 Do not scale drawings Use figure dimensions only. 14. All work to conform to the rules and regulations of the New York Energy Conservation Construction Code. All glazed area to be double glazed and all exterior doors to have insulated cores a 15. The Insulation protection as indicated on these plans exceeds the Code's minimum standards. __ _ 16.These drawings and specifications are instruments of service and �, - LU shall remain the property of the Engineer whether the project for _ _ - - ( , which they are made is executed or not They may not be used o PURCHASER, LE on any other project except by written authorization of the Engineer. WINDOWS o WS A5 SUPPLED �- BY , r-----------------------------------------I___ _ , ______________________ .__-_----__-_-_______________________ T, l _____ _ _ Ui"xll m _____ M GIRD ____________ _________ _____ __ FOUNDATION NOTES' _ i 112"Anchor Bolls @ 8'-0"O.C. Maximum � , °' � , .. 1 � $ `- 2. 8" Concrete Foundation Wall, 8'-0" High, 3000#Test ____ FURNACE i BE M POCKET IL � W 3, 16"x 8"Concrete Wall Footings,3000#Test o I SOLID 0QII 4. 2-1 %'x 11 718"Microlam Built-UpGirder-Grout Beam Solid In Pocket ------, .- ! - 5. 24"x 24"x 12"Concrete Column Feelings,30017#Test 6. 4"Concrete Floor Slab, 3000#Test with 616"410 mesh and vapor barrier •• p Q I I d) Y 7. Damp proofing and at exterior foundation below grade - 1 8 Foundation wall to extend a minimum of 8"above finish grade. o _ ___________� � a l I i I 9 '. 13 Q `9 9. Assumed soil bearing capacity, 2 ton per square fool, subject to inspection and verification ;e ; 5/e" F.O. GI -� 4 :, u 10. All footings to be carded down to undisturbed soil OVER FURNACE a m + 11 No footing shall be set higher or lower than a 30 degree angle from any other footing EXCAVATED CELLAR I LL > PER CODE J J n OM Z M - ' O N J 4' P.C. SLAB O '. 12. Pour no Concrete on frozen ground or in freezing weather. , O ON 4" POROUS FILL `----------- ----"---�--------- 13. 3 1/2"lally columns Tori W q M MATERIAL NOTES. , I I a' o FSE - l , l 18 3/4" Construction: `0 314"OSB plywood subAoor,glued I � � LL Nascor NJ 10 floor joists, spacing as noted _ __ ?-1 3/a'.II ve" r _111 _ _ c M.L. G M.L. IRDER IR 7 2-2x6 CCA SIII With termite shield and sell Seal IRDE M.L. G , 8 7 x T S T M.L. Glxl , a ' 1' 4 P , µ Finish fl00m a5 per agreement M L GIRDER 4-I 3/4"x11 lv0" IRDE S I - _ -� 3/4" - P T _ M POCKET 2-I 3/4' * ,T 9 ; IL/4 DER BEAM POG E ON 4C. SLAB ,, W 'i BEA � f 3 IQ ST 1 R ER '' ITCH POUROUS FILL _2-1 3/4" _ ' Roof Construction: ----- r ' To O.H.D.O.u.o. Asphalt Roof Shingles, 20 year 3-lab ." " GROUT SOLID I GROUT 5OL1 E 150 Felt Paper -* _ ., - -- EEL COLUMN 1/2"COX Plywood Sheathing , 2-F'�' l 0 ., �" - CONCRETE x12 POURED 2a'x24 2x10 Ridge,structural ridge as noted In O I I TYPICAL FOOTING, 00 .� 2x6,2x8, 2xlO Ceiling Joists 16' O.0 Roof Rafters @ 16O.C. as noted POUR HAUNCH 24"x12" 2x4 Cellar Ties @ 32O.C. p QJr Wall Construction. r d ; 2x6 Fascia,wrapped with aluminum m � e Overhang as noted a , '� m d � w ch Vinyl full vented soffits a O m I Aluminum gutters and leaders a - O 2_$u - Vinyl siding 0 d '. z N a JEFFREY T. BUTLER, P.E. Tyvek Housewrap Z > �. d I _ - - 1/2"COX sheathing a m u I ., LIJ p It 2x4 Studs @ 16"O.0 with 2x4 shoe and double 2x4 plate 'O .� ! U 00 i 1/2"Gypsum board '� I I X r ' 518"Type X in garage _ _ __ UNEXCAVATED GARAGE ° = H '_ _________________________ _________ Z 1/2"MR In wet areas _ _ _ _l ______ _______ __ _ __ ___________________________________________ ______ - a" P.C. SLAB l Windows manufactured by Alside, verify all rough openings ____ __ _______ _________________________________________ ______ FILL Al least one window in each room shall comply with exit requirements ---- ----------- ------ -- - - ON4" POURouSF l b .n 0 _________ _ r l l 0 u- ------------------------------------------------- . PITCH TO O.H.D Insulation. ,". 8, _ '. Z n 4"1 IR-13 m all exterior walls common with living areas and living areas common with garage , - u o 6" IR-19 in cathedral ceilings , COMPACTED FILL '• Z Z O 6" IR-19 in all flat ceilings 4" P.O. SLAB o ; 4" IR-111n all exterior garage walls _ '' '------------------------oW-t"_EORou9 Fu.�------------------- ------ O d) -A 7 FRAMING NOTES: FOUNDATION PLAN ., ! o 0 l Cr 1 All headers 2x12 unless noted ------------------------------------- - d m 3 2 All Corners are solid SMOKE DETECTOR ° Q s 3. Double jacks over 48"spans INTERCONNECT PER CODE " Ul 0 V 4. Double joists under all parallel partitions _ O 5. Provide fire stopping in all walls as per N Y.S Code DROP FIND TO GAR FL LEVEL w 6. Rafter heel cuts shall not exceed 4" 7. Where joists are notched to headers scras to reduce beam depth, use bridle irons or metal Connectors , �__ - - - - `0 8. All floor joists, rafters and ceding beams to be Hem fir number two or better construction grade with a minimum fb= 1200 p s l - , u F 9. All 2x4 and 2x6 partition walls to be Doug fir number two or better construction grade with a minimum to = 1200 p s.i. 1 LL IV 10. All beams and girders shall have 2"bearing mm I ---`7ERIFr�n-o.----------------------------- � O ' (> 21' 8" ,T 4' 11 1. 16'4' JS' 0" rU8" 1 AGE 65' 8" 2 of 3 3-1 3/4"X II VB" RIDGE 2xa RAFTERS REVIEWED AND APPROVED BY PURCHASER: I/2" COX 54EATHING 15' FELL REVIEWED AND APPROVED BY BUILDER: F r ASPHALT ROOF SHINGLES DONT RIDGE VENT ' -IS I ULATION v 0 1/2" GWB R-IB INSULATION 1/2" GILD 12 5 TOP OF PLATE 1'4" OH CONT. VINYL SOFFIT (TYP,) GWB m LIVING ROOM 0 2x4 STUDS DINING ROOM R-13 INSULATION 1/2" GOx SHEATHINGIA TYVEK HOUSEWRAP VINYL SIDING U w Z LL 3/4" SUBFLODR TOP OF SIIBFLOOR — — - R- 0 2x6 DCA TOP OF FOUNDATION— —- _ d w 12" RNID x 42" DEEP GRADE Z O 8 (OR TO UNDISTURBED SOIU AWAY �wgq POURED CONCRETE FTG FOUNDAT210N O K WITH 4X4 GGA POST 4 m _ ANCHOR TP FTG, 2-2X6 GOA BILL CELLAR 2-1 3/4' X II l/B" M.L- HDR. g TYPICAL 0 1/2" ANCHOR BOLTS WITH 3 I/2" STEEL COL- SILL SEAL ON P.G. FTG, TERMITE BPIELD 67 B" m B" GONG. FOUNDATIO 81 GONG. FTG. w D DAMPROOF BELOW GRAD 4" SLAB m TOP OF FOOTING 3 14' 0" �. 8.. 14. 8.. 10 4" 10, 0, w SECTION A-A 1 4' 0" 8. 4" I. 8„ 5. II T• 7. 3' 2 9, o.. 3, T„ v T” 4" VTR 4" VTR WINDOW SUPPLIED BY PURCHASER - - - - - - - - - - - - - - - 1 I 1 � 6 I wc . . 1 _ _ _ RR 1 a R _ _ _ _ _ _ _ _ _ Q 2842 -- _ _ _ _ J _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2856 2856 - _ _2856 _ - - .X .' C23 2?51� -r3 ____�_____ o ' -� ]B4C2_ Y 2_ HDR - - '�{w--=D_W_ J - DININ'- _ _-_ - J_==__ - 1 ►L. Q U- r__ O '^ 4 ft MA>xT BAH U __"_i G 4.. 1 11 _ 17. r TUB ---------2 wA9HErz s' �� - i" GOTH. c G O - � ml w ' m SINK FAI _ 30x301 hI = N SHOWER D.W. 1 �r ( 2'(1" u ; VENTEDi y U , N v L V L V I r W. GLA5 MAIN FLOOR I / SKYLT I - ------'w wr------ w 3 2.. 3.. 2.. 2. 2ii O O a 6KYLI F� = L ,I W 2.. 24 G.O. C.O. I O O ® w i m I O MASTER BEDROOM t 5 ®' o` 'o ¢ .a ayl lary Loi 1 O 3.. 4" G.I.TO AN APPROVED I 9 a 1 •O L, 3 SANITARY SEPTIC SYSTEM I a B'O" CLG. PGT, p p 1L' m 30x45 1 Ul Wi 30.45 iW = m 1 m FRAME WALL TO R.R. r X I W i VENTEDi W �� VENTED iH L _ – – – – – – – – – – O W W.LG. KITCHEN o] tll m' ,t – -I NOTE HEADER m Z HOUSERTRGP - 1 – U Oi GLA55 10 Oi GLASS } Ul O r 1 m O o - CATH. GLC. p 1 SKYLITEip pl SKYLITEIp AT 02 1l2" ABOVE "* L______4 L------4 FINISHED SLAB °O FI PLUMBINCz RISER DIACsRAh I (NTS) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ — UTILITY 1 14' S" T. 5' 0" ¢ �j " PC SLA 1 7 = FRAME WALL TO �I m 13 O v1ILL / BOTTOM OF R.R. f Y 0 7 (I�. !�/ BEARING WALL T /" 1O j 1 6.� - 2-1 3/4"x9 1/4" M.L. HDR. 2-2X10 HDR. tK r — _ _ _ — _ _ _ _ ^ U m ]XIO RIDGE m T� L o 3-I 3/4 XII 1/8 15-M.L. RIDGE m �p 1 ENGI ER: =O STEW$ O ptEp m POST ABOVE 4-2x4 III D" c ^z' III - Y 0 LL y�4 rh TO RIDGE P05T L - _ - - - - - - - OF NEI', 1 ROOF RAFTER L/ �� - HURRICANE CLIP NAILED 3 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ T - POCKET ?' 6" I / TO RAFTER i PLATE Y 1 2-2X10 HDR. ® k, , Q U LIVING ROOM FC / I * e 3ip (D2"x4" TOP PLATE6 + O 6" r- -S-(1°iWS.FQ 19Aa H. CLG. �D Il CI S 10" ¢: _ K - - y - 1 30z45 Z `-� BEDROOM "1 NTEp i�o Ie w – ' e'o" cLG- PGT. 3 GL 65 J x T„ 4„ JEFFREY U ER, P.E. to U LREIO 4' 0" IL 15 _ 2 CAR GARAGE 5/0" F C. GWB ON WALLS i W O k ry/ AND CEILING PER CODE , TILED — :o o x X 4" 4' 17 w 4" P.0 SLAB W fi HURRICANE CLIP DETAIL B/SHGWER x = ~it ~I r g W� o 1 2-1 3/4" X E 1/4" M.L. HDR, FI F "' p� z m - - - o� - - -- - 2842-3 2656 856 w O O O L _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ COVERED PORCH U w n _ o u Q 3 ° ul RAISE BOTTOM 4" P.G. SLAB p U / 1 W OF CLOSET AS I n m S )- 9 ; REQUIRED FOR ry d a 1 z RIDGE VENT FIRST FLOOR PLAN HEADROOM BELOW 1 / 1 � SHINGLE RIDGE CAP--\ / 2-2 10 B.U. PORCH GIRDER -- __ _ 2xl C.J.I e 16" O.C. m O O MAIN LIVING AREA = 1224 SQ,FT, STEP /SPAN 43 _ _O EXHAUST AIR L _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 Q ON � s HANG FR M RDGE T D GARAGE AREA = 430 SQ.FT, PROVIDE FIRE SEPERdTION 2x8 R.R. 2x8 R.R. YJ SPINGLES� ROOF SHEATHING RYP./ EVERY 20' MAX. --- � a 16" O FELT PAPER LAUNDRY AREA = 90 SQ.FT, 0 16 o.c. I 1 COVERED PORCH AREA = 126 SQ.FT. u � lAS' M.L. HDR N LL e 1 - -__ - I I 1 0 ' � SMOKE DETECTOR I � - - - - -- - O o RAFTER INTERCONNECT PER CODE L - - - _ - - - - - - - - - - LO.u.D_ - - - - - - - _ - - - O -P F _ > (L o "a 10 10" 16' 6" 10. I• TT 10' 4" 10.4.. RIDGE BEAM 45- 0" '_II 6" PAGE : RIC)SE VENT DETAIL 65 a" 3 of 3