Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
42441-Z
gFFf��,fl'' Town of Southold 5/2/2018 0 P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39620 Date: 5/2/2018 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 5660 Sound Ave, Mattituck SCTM#: 473889 Sec/Block/Lot: 121.-4-2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/1/2018 pursuant to which Building Permit No. 42441 dated 3/8/2018 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Carlson,Jeffrey&Dawn of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 42441 04-18-2018 PLUMBERS CERTIFICATION DATED Authorized Signatur o�SU n ecoTOWN OF SOUTHOLD "b, BUILDING DEPARTMENT TOWN CLERK'S OFFICE o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 42441 Date: 3/8/2018 Permission is hereby granted to: Carlson; Jeffrey & Dawn 5660 Sound Ave Mattituck, NY 11952 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 5660 Sound Ave, Mattituck SCTM #473889 Sec/Block/Lot# 121.4-2 Pursuant to application dated 3/1/2018 and approved by the Building Inspector. To expire on 9/7/2019. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 B pector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I% lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 Date. New Construction. Old or Pre-existing Building: (check one) Location of Property: 5rofc0 S0v_,,c( f� VZh Lt I Ma *�4�-Jfz__ House No. Street Hamlet /� Owner or Owners of Property: �e.��rL C—ot^rAgo Suffolk County Tax Map No 1000, Section �'�� . C)®D Block 4 O 0d O Lot 2. cpod Subdivision Filed Map. Lot:// L Permit No. � Date of Permit. Applicant: r an,e.lroh 6A nAz,,n 9&k:h Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ �y i Applicant Signature pF SO!/j�®! Town Hall Annex Telephone(631)765-1802 54375 Main Road y Fax(631)765-9502 P.O.Box 1179 C§ �Q roger.richert(aD-town.southold.ny.us Southold,NY 11971-0959 Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Marinello (Carlson) address: 5660 Sound Avenue city;Mattituck st: New York zip: 11952 Building Permit#: 42441 Section- 121 Block: 4 Lot: 2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Island Electric License No: 37608-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures f] TVSS Other Equipment: 6,27 KW Roof Mounted Photovoltaic System to Include: 22- 285 W Panels with 22 Enphase Micro Inverters, Combiner Box, AC Disconnect. Notes: Inspector Signature: Date: April 18, 2018 0-Cert Electrical Compliance Formas momentum SOLAR April 25,2018 - ---- - ------ ------- - ----- -- ---- - ---- Town of Southold Building Department 54375 Main St Southold , NY 11803 - - --- - - - ---- --- = - Subject:" Architect Statement for Solar Rooftop Installation Residence-Jeff . Carlson-5660 Sound,Ave, Mattituck,NY 41-952 Permit No#4244-1 Post Installation"nsp ction Date: 4/1/201=$__` The rooftop photovoltaic systemat the above refereneed`residence has been observed to be installed" -" properly iif-accordance with the-approved plans and is_ceitified by Daniel.W Dunzik Architectural _ rvice's; P.C. to be in compliance:with the minimum requirements of the-'T6- Sewri�"the 2015-Internation4l. Residential_Code and the 20'1.6=Ncv�York State Unifo m:Code Supplement and-the Provisions of_$:=. , _ = ASCE zi - - - - " 6 N� istetc 039591 0 OF N - - --- MAY - 1 2018 - - 325 High Street D:732.902.6224 Metuchen,New Jersey -'' " � 's�jam'. F:732.902.6223 o8840 TOWN OF soumom W:momentumsolar.com SOUTyolo TOWN OF SOUTHOLD BUILDING DEPT. 765-1602 INSPECTION ( ] FOUNDATION 1ST [ ] ROUGH PLEIG. ( ] FOUNDATION 2ND [ ] INSULATION ( ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION'[ ], FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) REMARKS: DATE l INSPECTOR o' FIELD INSPECTION REPORT DATE COMMENTS Xll ,b FOUNDATION 1ST ------------------------------------ C 'FOUNDATION (2ND) �v'j c Iq O ROUGH FRAMING& y 4 PLUMBING fl r INSULATION PER N.Y. H STATE ENERGY CODE r� k- FINAL ADDITIONAL COMMENTS t - �. T R o z X i IS �N z H d TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION,CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL , Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 = Planning Board approval FAX: (631) 765-9502 42 / 2 Survey Southoldtownny.gov PERMIT NO. C Z Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application, Flood Permit Examined ,20 Single&Separate Truss Identification Form Storm-Water Assessment Form �Q� Contact: Approved 20 = Mail to: Disapproved a/c Phone: / D D BJinspectcr MAR - 1 2018 APPLICATION FOR BUILDING PERMIT (j TOWN OF SOUTHOLD Date / , 201 INSTRUCTIONS a.This application MUST be completely filled,in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall-be required. APPLICATION IS HEREBY MADE to the.Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for,necessary inspections. (Signature of applicant or name,if a corporation) 45 Fairchild Ave. Suite B Plainview 'NY 11803 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder C'ontra�t�r Name of owner of premises r Cada)a (As on the tax roll or latest deed) If ap licant is a corporation, signature of duly authorized officer m P ro rlrar i 5+e-nst (n (Name and title of corporate officer) Builders License No. Cj -7 P�-� 63 -- —1 Plumbers License No. Electricians License No. 3�s08-nnE Other Trade's License No. 02>q 5 b L1 1. Location of land on which propo edAwork will be done /t hl IBJ"( l rJ 2 House Number Street Hamlet County Tax Map No. 1000 Section 12U-ABlock @ Lot Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and oFRpancy�of proposed construction: a. Existing use and occupancy _ �cjmiu b. Intended use and occupancy S 1^ I I I P,2:25'tder)(2,-,. 3. Nature of work(check which applicable):New Building _ Addition X Alteration Repair Removal Demolition Other Work ��['�� 4. Estimated Cost do- 2 283 v 5 8 Fee (Description) (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars. = 6. If business, commercial or mixed occupancy, specify nature and extent of-each type of use. 7. Dimensions of existing structures, if any:Front . Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front -Rear Depth Height Number,of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of;Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?'YES NOx 13. Will lot be re-graded?YES NO Will excess fill be removed from premises?YES NO 5(D(o o SOUr)d Ave- 14.Names of Owner of premises Carl 5 O n Address wa+i+uck,XA4 i I q 5 2 Phone No. (r3 I-27(0- 91-7(p HiH Name of Architect Daniel W. Dunzik Address SdOIIBantNY 85'58 Phone No A(1R-R79-RRR4 Name of Contractor_Cb Prn n Chris nSQr� Address '�Z �"r ' 'i `e;,e „Phone No. (u31-6te�-y 15 a. Is this property within 100,feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO) * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) Cameron Christensen being duly sworn,deposes and says that(s)he is the-applicant (Name of individual signing contract)above named, (S)He is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this'application; that all statements contained in this,application are true=to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of 2019 G IAMMANCO ry Public - of New York Signature of Applicant No.01 G16341027, Qualified In Suffolk County My CoMWWion Expires M'a'y 2,2020 Scott A. Russell 0: 5 STORMWA\T]E K SUPERVISOR �T ( �T � � I��1[A\I�A\G�]EI��l[]EI�'7C' SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 �o� Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) - - ]CD®FE,S THIS PROJECT INVOLVE ANY OF THE FOLLOWING: No (CHECK ALL THAT APPLY) Yes ElA. Clearing, grubbing, grading or stripping of land which affects more /than 5,000 square feet of ground surface. ❑0 B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑[3�`C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑ Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑ EXon Site preparation within the one-hundred-year floodplain as depicted FIRM Map of any watercourse. ❑ Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT (Property Owner,Design Professional,Agent,Contractor,Other) S.C.T.M. #: 1000 Date. ' I � � � District ^ 1 NAME. G..Yv�E:lfbV\ CO�Y� Qft1 -� � �'s�J— �r Section Block Lot /( rj\'g°„"" FOR BUILDING ARTN,,IENT UONLY ONY Contact information- `t°r/3f 53G— 4100 _� ;telephone Nuinher) y— Reviewed By- - — — — — — — — — — — — — — — — — — Date: \3—)—)J'Property Address/ Location of Construction Work: — — — — — — — — - - - - - - - - -- - - - - - - - Approved for processing Building Permit. Stormwater Management Control Plan Not Required. ❑ Stormwater Management Control Plan is Required (Forward to Engineering Department for Review.) FORM # SMCP-TOS MAY 2014 g�fFOtk BUILDING DEPARTMENT- Electrical Inspector ��0 COG TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 o Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 roger.richert(aD_town.southold.ny.us APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: I-A p Sot v,-� Date: `� Company Name: sl�,� �le�-�-�c, Cor Name: e_ r t-Ao-e-i eAk License No.: 3-7620 $- Ir email: Address: �S� L0 r, 6, W 1 1150 Phone No.: -3 SCo - U 100 JOB SITE INFORMATION: (All Information Required) Name: Address: G2Gp o --yuck I1 5� Cross Street: KirkL&P Phone No.: I Bldg.Permit#: email: Tax Map District: 1000 Section: 10-Waft, Block:y, Lot: 2 BRIEF DESCRIPTION OF WORK (Please Print Clearly) oo-�--�a CAIhA--}ia -Ie�aJ U (42-971 1c-W s t-" sir.1, Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service - Fire Reconnect - Flood Reconnect - Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y 'N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection FormAs � t � SOUTyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road N Fax(631)765-9502 P.O.Box 1179 G • Q Southold,NY 11971-0959 'Q a Cow N, April 27, 2018 BUILDING DEPARTMENT TOWN OF SOUTHOLD Momentum Solar 45 Fairchild Ave Plainview NY 11803 RE: Carlson, 5660 Sound Ave, Mattituck TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: NOTE: Need Engineer's certification letter stating the panels were installed to the roof per NYS Building Code Electrical Underwriters Certificate A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4!1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 42441 - Solar f. A Su HOME IMPROVOMENT SALESPERSON �O I i w_17 SUFFOLK COUNTY DEPT OF IABOR 'r LICENSING&CONSUMER AFFAIRS' LICENSEE { HO E IMPROVEME T - CONTRACTOR Name:CAMERON ��C�H►RIS'IENSENLICENSE ;J •dg fivet-Iama*2042929-DCA - ° CAMERON CHRISTENSON ,'`,4�";•�*=x EWratbn Date:Feb 28,2017 This certifies that tRe PR®CUSTOM SOLAR LLC Den bsamr is duly ! - `- licensed by the County of Suffolk *aa�a9.3o16-AtiIs� 67678-H ���rzo16 f eum,nx, cnwewocfa j(Vn1M1A1R aoa »r+ 116 r � PROCU-1 OP ID:LM CERTIFICATE OF LIABILITY INSURANCE DATE12!11112017/2017 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS-WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certiflcate holder in lieu of such endorsement(s). PRODUCER CONTACT Lisa MacDonald Brown&Brown Insurance NAME: O 2000 Midlantic Dr.-Suite 440 IlucC.No,Ext),732.504-2001 (ac;Nei;732.504-2011 Mount Laurel,NJ 08054 E-MAIL Brian DiLuigiADDREss:Imacdonald@bbdvins.com INSURERS AFFORDING COVERAGE NAIL# INSURERA:Gotham Insurance Company 25569 INSURED Pro Custom Solar LLC dba INSURER B:New York Marine&Gen Ins Co 16608 Momentum Solar INSURER C:Hiscox Insurance Company 45 Fairchild Ave Suite B - P y Inc 10200 Plainview,NY 11803 INSURER D: INSURER E: INSURER F: _ COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR m_ POLICY EFF POLICY EXP LTR TYPE OFINSURANCE INsD'WVD POLICYNUMBER MMIDDNYM IIMMIDDIYYYYI LIMITS A t X `COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,00 CLAIMS-MADE ®OCCUR GL201700010727 112/1212017 12112!2018 AMAGETO-RENTED 100 00 PREMISES fEa occurrence $ , MED EXP(Any one person) $ 5,00 PERSONAL&ADV INJURY $ 1,000,00 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,00 1 POLICY®JFCT F LOC PRODUCTS-COMP/OPAGG $ 2,000,00 I OT ER- $ AUTOMOBILE LIABILITY I�MaBBIIiNdEe�SINGLE LIMIT $ 1,000,000 B X ANY AUTO AU201700012651 04121/2017 04/21/2018 BODILY INJURY(Per person) $ JALL OWNED SCHEDULED BODILY INJURY Per accident $ AUTOS AUTOS ( ) X HIRED AUTOS J'X NON-OWNED ROPER DT1T AMAGE $ _ AUTOS Per accident I Is X UMBRELLA LIAB X I OCCUR EACH OCCURRENCE $ 5,000,00 -MADE UM201700004884 12/1212017 12/12/2018 A EXCESS LIAR CLAIMS AGGREGATE $ S,000,OO DED X RETENTION$ 10000 $ WORKERS COMPENp SATION - P O AND EMPLOYERS'LIABILITY X 1 STATUTE ER B ANY PROPRIETOR/PARTNERIEXECUTIVE YIN WC201700012773 12112/2017 '1 211 212 0 1 8 E.L.EACH ACCIDENT S 1,000,00 OFFICER/MEMBER EXCLUDEDI N❑N I A (Mandatory In NH) E L DISEASE-EA EMPLOYEE $ 1,000,000 If es,dascnbe under DESCRIPTION OF OPERATIONS below I E.L.DISEASE-POLICY LIMIT $ 1.000,000 C IProfessionai Llab I NE1860007.17 12/01/2017 12/12/2018 Limit 1,000,00 (CLAIMS MADE) I DESCRIPTION OF OPERATIONS 1 LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 53095 Middle Road ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD a N)R Workers' CERTIFICATE OF sr�trla Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Pro Custom Solar LLC dba 732-902-6224 Momentum Solar 45 Fairchild Ave Suite B Plainview,NY 11803 1c.NYS Unemployment Insurance Employer Registration Number of Insured Work Location of Insured(Only required if coverage is specifrcallylimited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations In New'York State,t.e.,a Wrap-Up Policy) Number 271-24-2539 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) New York Marine 8r General Insurance Co. Town of Southold 53095 Middle Road 3b.Policy Number of Entity Listed in Box"1 a" Southold,NY 11971 WC201700012773 3c.Policy effective period 12/12/2017 to 12/12/2018 3d.The Proprietor,Partners or Executive Officers are X❑ included,(Only check box If all partners/officers included) ❑ all excluded or certain partnersfofficers excluded. This certifies that the insurance carrier indicated above in box 1"insures the business referenced above in box'1 a'for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation Insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the cetlificate holder in box"2". Will the carrier notify the certificate holder within 10 days of a policy being cancelled for non-payment of premium or within 30 days if cancelled for any other reason or if the insured is otherwise eliminated from the coverage indicated on this certificate prior to the end of the policy effective period? [-]YES E]NO This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form,If the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide,that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized.representative or licensed agent of the Insurance carrier referenced above and that the named Insured has the coverage as depleted on this form. Approved by:Christine Howley (Print name of author¢ epresentative or licensed agent of insurance carrier) Approved by: 12/11/2017 (Signature) (Date) Program Manager Title: Telephone Number of authorized representative or licensed agent of insurance carrier. (973) 532-1758 Please Note,Only Insurance carriers and their licensed agents are authorized to Issue Form C-105.2.Insurance brokers are NOT authorized to issue it C-105.2(9-15) www.wcb.ny.gov IDF created with pdfFactory trial version www.pdffactory.com i . ORRNEWK Workers' CERTIFICATE OF INSURANCE COVERAGE STATE JlCompensatlion Board UNDER THE NYS DISABILITY BENEFITS LAW PART 1. To be completed by Disability Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured (732)902-6224 PRO CUSTOM SOLAR LLC DBA MOMENTUM SOLAR 1c.NYS Unemployment Insurance Employer Registration Number of 45 FAIRCHILD AVE SUITE B Insured PLAINVIEW,NY 11803 Work Location of Insured(Only required if coverage is specificalfy fimited to Id.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,Le.,a Wrap-Up Policy) Number 271-24-2539 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Cartier (Entity Being Listed as the Certificate Halder) New York State Insurance Fund(NYSIF) 3b.Policy Number of Entity Listed in Box"1a" TOWN OF SOUTHOLD DBL 6824 29-7 53095 MIDDLE RD SOUTHOLD,NY 11971 3c.Policy effective period 12/14/2016 to 12/14/2018 4.Policy covers: ® A.All of the employer's employees eligible under the New York Disability Benefits Law B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability Benefits Insurance coverage as described above. Date Signed 12/18/2017 By �- " Joseph J.Masi (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that msurence carrier) Telephone Number(866)697-4332 Title Director of NYSIF Disability Benefits Insurance IMPORTANT: If Box"4a"Is checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box"4b"is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the Disability Benefits law.It must be mailed for completion to the Workers'Compensation Board,DB Plans Acceptance Unit,328 State Street,Schenectady,NY 12305 PART 2.To be completed by the NYS Workers'Compensation Board(Only if Sox"411b"of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability Benefits Law with respect to all of his/her employees. Date Signed By Signature of NYS o ars Compensabon Board Emplore) Telephone Number Tide Please Note: Only insurance carriers licensed to wfite NYS disability benefits insurance policies and NYS licensed Insurance agents of those insurance carriers are authorized to issue Form DB-120.1.�Insurance brokers are NOT authorized to Issue this form. DB-120.1 (9-15) Certificate Number 465975 ,'3 Daniel W. Dunzik Architect LEED-AP Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd.Skillman,NJ.08558 908-872-3664 370 Burnt Hill Rd.Skillman,NJ.08558 908-872-3664 February 17,2018 Ch.30 Wind Loads Components and Cladding -windloads=140 mph Exposure B zone 1=+-/-31.4 psf.,Zone 2&3=+/-77.7psf. Mattituck,NY Area of Panels largest array=920.7 sf ' Tributary area panels/attachment max.920.7sf/382.8m,n= l ISE Attn:Construction Official Min Number of Attachments=34. Wind pressure 31.4 x Area 382.8/34 No.Attachments=874 Re: Proposed Photovoltaic Solar Panel Installation TABLE 10.3.1 NDS Pull out strength of 5/16"x4"lags in rafter=W'=WxCdxCt=2661bs/in Jeffrey Carlson embedment x 2.5"embedment x1.6Cd x1.0Ct= 1,064 Lbs Max.>874 lbs/attachment OK 5660 Sound Ave. Mattituck NY 11952 3.Solar modules shall be UL-1703 rated. Refer to manufacturers specifications sheets. Dear Sir: 4.Positive drainage of the system shall be so as not to void the existing roof warrantee. Certification:I have reviewed the engineering testing reports for the racking and attachments to be used on this project and I certify that the products are capable of supporting the code S.2017 New York State Uniform Code,the 2015 International Residential Code,1m Printing, required loads and are suitable for this installation when installed in strict compliance with the as amended by the 2017 New York State Uniform Code Supplement,ASCE-7-10,2014 manufacturers printed instructions. National Electric Code,All Local Governing County and Municipal Ordinances adopted by reference or enacted by law. Regarding the solar panel array installation on the above referenced project please note that An inspection was performed and analysis of the existing structure was conducted.There is adequate structural capacity for the installation of the array with the following If you y ons relating to this matter,please contact me at your earliest recommendations: co cq � 1.The array will be installed on the existing roof.The roof is constructed of 2"x6"wood rafters ��\�oP����\s✓u���b �� @ 16"O.C.spanning 10'5"with 1"x6"T&G wood sheathing.The new array(See Site map by contractor)will add 2.63 Lb./Sf overall to the roof.No additional structural support is COMPLY WITH ALL CODES OF required for the existing roof structure. t NEW E WYO � ®TATE 8,OWN CODES AND 2.The system shall be secured to the roof using the"Ecofasten Solar""Rock-IT"®attachment N �D1T1O�� OF system.The installation'shall be in strict compliance with manufacturers printed instructions. X 039534 0 The attachment system shall be UL 1703 approved tested.The attachments shall be min.5/16" D D-AP x 4"long stainless-steel lags with a min.embedment of 2''/s"into the rafters.Attachments shall NY. L1 be @ 48"o.c.Max.in roof wind zone 1 and @ 24"o.c.Max.in roof wind zone 2 and 3 lags to $® alternate rafters. Provide 6 mil.vapor barrier between dissimilar metals.Provide water tight APPR VED AS NOTED gasket and sealant at all penetrations. Attachments shall follow panel rows as specified by the system manufacturer's installation manual.The panel angle shall match the roof slope. DATE-3-hon *4_0 Z _ Structural Desi Loads per ASCE 7-10 BY; p FEE:= ® R p NOTIFY_;Bij .QING DEPAR,, I4' ®� U u Y OR -Dead Loads= 10 psf(+2.6psf,New Solar Panels)=12.6 psf.-Live Load=25 psf T AT 765-1802 ,'8 Alt : TO 4 PM 'FO THE' 2 UNLAWFUL p�p g�f Total dead weight on attachment=27 Lb.Max. FOLLC�YIfINIa i $pCTI� R Lam— 4�tl LAif U P 1'. FOUNDA7Idt . - TWb'REQUIRED` W !r U UT C E RT F!"",77 FOR PO.tAto CONCRETE = 2.,ROU,GH_=;FRAMING & PLUMBING ®F OCCUPANCY 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. , ALL CONSTRUCTION SHALL MEET THE ELECTRICAL REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR ��������®� �������� DESIGN OR CONSTRUCTION ERRORS. PLAN KEY SYSTEM INFORMATION PV-1 COVER PAGE MODULE LONGI LR6-60 285M momentum PV-1(1) COVER PAGE CONT. INVERTER ENPHASE IQ6-60-2-US _ SOLAR PV-2 PANEL LAYOUT RACKING ECOFASTEN ROCK-IT SYSTEM PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR PV-3 LAYOUT DETAIL SYSTEM SIZE DC 6.27 KW 325 HIGH STREET,METUCHEN,N]08840 (732)902-6224 PV-4 ELECTRICAL MOMENTUMSOLAR.COM LOCATION 40.98S90193 , -72.56065357 PV-5 EQUIPMENT LABELS STRUCTURAL ENGINEERING GENERAL NOTES: DANIEL W.DUNZIK RA LEED-AP LICENSE#039534 (908)872-3664 370 BURNT HILL ROAD SYMBOL LEGEND THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS slaum N,NJ 08558 ENGLETTERATTACHED HAS SPECIFICATIONS FOR FOR BUILDING AND OTHER STRUCTURES OF THE 2017 NEW YORK STATE UNIFORM ANDILOAD ICALCULATIONS FOR SOLAR INSTALLATION SPANS&IND CODE THE 2015 INTERNATIONAL RESIDENTIAL CODE 2ND PRINTING AS AMENDED ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE / / / COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR MSP MAIN SERVICE PANEL ® CHIMNEY BY THE 2017 NEW YORK STATE UNIFORM CODE SUPPLEMENT, ASCE-7-10, 2014 ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFA NATIONAL ELECTRIC CODE, ALL LOCAL GOVERNING COUNTY AND MUNICIPAL LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. ORDINANCES ADOPTED BY REFERENCE OR ENACTED BY LAW. SP SUB-PANEL z SKYLIGHT ,�, ED q,4 AN 18" WIDE (FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED ALONG AT LEAST 5 UTILITY METER ® VENT ONE SIDE OFw _THE ROOF ON THE SAME SIDE AS THE SOLAR EQUIPMENT OR ON !� pP� W ANOTHER SIDE OF THE RIDGE THAT DOES NOT HAVE SOLAR EQUIPMENT ON IT. IN `' n,A AC AC DISCONNECT' 0, PIPE VENT ADDITION AN 18" WIDE PATHWAY(FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED, s,,p Dc FROM AT LEAST ONE EAVE. UDC UTILITY DISCONNECT FAN Cn� ROOF SHALL HAVE NO.MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE _ SOLAR EQUIPMENT. '9 � LC LOAD CENTER � SATELLITE DISH <�l 039534 y0O INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND F NE� N3R NEMA 3R BOX W/ENVOY-S ® FIRE SETBACKS NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. N3R] NEMA 3R BOX W/ENVOY-S WEIGHT OF THE INSTALLED SYSTEM SHALL NOT EXCEED MORE THAN 5-PSF FOR CUSTOMER CB COMBINER BOX GROUND ACCESS PHOTOVOLTAIC AND NO MORE THAN 6-PSF FOR RESIDENTIAL SOLAR HOT WATER SYSTEMS. INFORMATION EMODULE -► PITCH DIRECTION JEFFREY CARLSON ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT 5660 SOUND AVENUE INSTALLATION. ANY RELOCATION OR MODIFICATION,OF THE VENT REQUIRES A 5660 SUNCK, A ENUE PLUMBING PERMIT AND INSPECTION. 11952 631-276-9176 INVERTER PLACEMENT: JURISTICTION:SUFFOLK BILL OF MATERIALS UTILITY:PSEGLI SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL UTILITYACCT#:9690328501 LOCATED ON THE BACK SIDE OF EACH MODULE. MODULES 22 UTILITY METER#:63129319 BUILDING REVIEW NOTE: INVERTERS 22 PV SYSTEM TOWN BUILDING PLANS EXAMINER-HAS RECEIVED THE ENCLOSED DOCUMENT FOR CLAMP ASSEMBLY 55 INFORMATION MINIMUM ACCEPTABLE PLAN SUBMITTAL REQUIREMENTS OF THE'TOWN AS SPECIFIED COUPLING ASSEMBLY 28 SYSTEM SIZE(DC):6.27 KW IN THE BUILDING AND/OR RESIDENTIAL CODE OF THE STATE OF NEW YORK. -BONDING CLIP 5 22 MODULES:LONGI LR6-60 285M THISREVIEW DOES NOT GUARANTEE COMPLIANCE OF THAT CODE. THAT 22 INVERTERS:ENPHASE 1q6-60-2-US RESPONSIBILITY IS GUARANTEED UNDER THE SEAL AND SIGNATURE OF THE NEW- SKIRTS = 7 - YORK LICENSED DESIGN PROFESSIONAL OF RECORD. THAT SEAL AND SIGNATURE HAS BEEN INTERPRETED AS AN ATTESTATION THAT, TO THE BEST OF THE LICENSEE-S ENPHASE COMBINER BOX 1 BELIEF AND INFORMATION, THE WORK IN DOCUMENT IS: 60A FUSIBLE AC DISCONNECT 1 PROIECiINFORMATION 1. ACCURATE 30A FUSES 2 2. CONFORMS WITH GOVERNING CODES APPLICABLE AT THE TIME OF THE INITIAL DATE:2/13/2016 DESIGNER:MM SUBMISSION. 125A LINE TAPS 2 REV: DATE: DESIGNER: 3. CONFORMS WITH REASONABLE STANDARDS OF PRACTICE AND WITH VIEW TO REV: DATE: DESIGNER: THE SAFEGUARDING OF LIFE, HEALTH, PROPERTY AND PUBLIC WELFARE IS THE RESPONSIBILITY OF THE LICENSEE. COVER PAGE PV- 1 SEE NT DULE 1. ALL WIND DESIGN CRITERIA ARE FOR GABLE AND HIP RESIDENTIAL ROOFS FOR MAXIMUM CANTILEVER FOR MAXIMUM CANTILEVER CONSIDERED FROM AN ANGLE OF MIN.9.5" (12)TO MAX.45"(1)NOT TO EXCEED COUPLING Q 30'MEAN ROOF HEIGHT WITH A MIN 5' LAG BOLT(ASTE A276)STAINLESS STEEL CLAMP& momentum 'INTO THE RAFTER OR BLOCKING BETWEEN RAFTERS W/MIN. EMBEDMENT OF 3" ATTACHMENT 2. THIS STRUCTURAL DESIGN REFLECTS STRUCTURAL CONNECTIONS TO THE RAFTE SOLAR LONGI LR6-60 285M EXISTING STRUCTURE ONLY. MODULE TO ROCK-IT LOADING AND CERTIFICATION SOLAR MODULE 285 WATT MODULE PER MECHANICAL LOAD TESTS IAW/ANSI UL2703 CONDUCTED ON BEHALF OF ECOFASTEN SOLAR BY TUV RHEELAND REFERENCE FILE L2-ELS150128a REV 1 PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 65" X 39" X 1.6LL ( ) 325 HIGH STREET,METUCHEN,N]08840 (SEE DATASHEET) 3. ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511 AND IS THE (732)902-6224 RESPONSIBILITY OF THE CONTRACTOR TO FILL ALL HOLES WATER TIGHT. GUTTE MOMENTUMSOLAR.COM 4. "ROCK-IT"ATTACHMENTS ARE MANUFACTURED BY ECOFASTEN SOLAR,PHOENIX, STRUCTURAL CLIMATIC & GEOGRAPHIC DESIGN ARIZONA.AND SHALL BE INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURERS PRINTED INSTRUCTIONS. MINIMUM S SPACING TO GUTTER---JEERING DANIEL W.DUEE NGRA LEININ CRITERIA TABLE_ R301.2(l) ECOFASTEN SOLAR ROCK-IT MOUNTING DETAIL LICENSE u 039534 ROCK-IT TO RAFTER ATTACHMENT SPACING SCHEDULE ECOFASTEN SOLAR ROCK-IT MOUNTING SYSTEM INTEGRATES (908)872-3664 GROUND SNOW LOAD 25 LBS/SF WITH FLASHING,COUPLINGS AND ADJUSTABLE CLAMP 370 BURNT HILL SKILLMAN,NJ 08558D ATTACHMENTS ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND SPEED (MPH) 135 MPH ULTIMATE AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE ROOF ZONE 1 &2 ROOF ZONE 3 MAXIMUM SOLAR ARRAY ELEVATION:4.25" COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR TOPOGRAPHIC EFFECTS B DESIGN ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFA WIND MAX.SPAN/MAX. MAX.SPAN/MAX. LICENSED ARCHLTECi,TO ALTER AN ITEM IN ANY WAY. SPECIAL WIND REGION NOCANTILEVER CANTILEVER MAXIMUM CLAMP ATTACHMENT SPACING:48" SPEED (INCHES) (INCHES) WIND BORNE DEBRIS ZONE 2 (MPH) ED ARc 115 48"O.C./16"MAX. 32"O.C./12"MAX. DO SEISMIC DESIGN CATEGORY C 125 48"O.C./16"MAX. 32"O.C./12"MAX. COUPLING �fflCLAM �� OP �sv-- ir �C' CLIMATE ZONE 5A 130. 48"O.C./.16"MAX. 32"O.C./12"MAX. -A 140 48"O.C./16"MAX. 24"O.C./10"MAX. SOLID BLOCKING WIND EXPOSURE CATEGORY B 150 48"O.C./16"MAX. 24"O.C./8"MAX. BETWEEN JOISTS 0 160 32"O.C./12"MAX. 16"O.C./8"MAX. pm TABLE REFLECTS ATTACHMENT SPACINGS.THAT EXCEED MANUFACTURERS w ��� 039534 �pQ� SPECIFICATIONS FOR WIND LOADS AS PER ASCE 07-10. RISK CATEGORY II "' QF NE TOPOGRAPHIC EFFECTS BIC,&D AND ROOF WIND ZONES 1,2,&3. ROOF ZONES 2&3 FASTENER REQUIREMENTS: ARE WITHIN 36"OF ANY OUTER EDGE, HIP,RIDGE,OR GUTTER LINE FOR STRUCTURES 30'-0" OR LESS MEAN ROOF HEIGHT. TOTAL ARRAY AREA=387.29 SQ FT WIND LOAD:ASCE 30(SEE CALCULATIONS,STRUCTURAL CERTIFICATION)50 PSF MAX TOTAL UPLIFT 50 PSF X 387.29=19364.58 LBS CUSTOMER GUTTER GUTTER INFORMATION ® ® ® jO FASTENER: LAG SCREW SPEC 203.2,8/04:(FLAT WASHERS TO BE USED WITH LAG BOLTS) JEFFREY CARLSON W LAG BOLT WITHDRAWAL VALUE 5/16"DIA.,266 LB/IN X 2-INCH THREAD DEPTH: 5660 SOUND AVENUE © Q ® 532LB.CAP.EACH MATTITUCK,NY,11952 MINIMUM NUMBER OF LAG BOLTS REQUIRED:19364.58 LBS/532 LBS/LAG BOLT=37631-276-9176 MAXIMUM SPAN BETWEEN MOUNTING FEET BOLTS"X"USE 48"MAX ALLOWED AS ® O RIDGE RIDGE ® ® PER'SCHEDULE D JURISTICTION:SUFFOLK STRUCTURAL STATEMENT: UTILITY:PSEGLI YUTILITY ACCT#:9690328501 ® © © THE EXISTING STRUCTURE IS ADEQUATE-TO SUPPORT THE UTILITY METER#:63129319 NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE © ® GUTTER ® GUTTER SYSTEM INCLUDING UPLIFT&SHEAR.EXISTING RAFTER PV SYSTEM SIZES &DIMENSIONS CONFIRM TO IRC-2015 TABLE INFORMATI.ON - R802.5(1)-RAFTER-SPANS. SYSTEM SIZE(DC):6.27 KW ROOF WIND ZONES AS PER IRC R301.2(7) 22 MODULES:LONGI LR6-60 285M ROOF ZONES 2&3 ARE 36"FROM OUTTER ROOF EDGES, MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED NEW YORK STATE CODE REQUIREMENTS FOR THE DESIGN 22 INVERTERS:ENPH_ASE IQ6=60-2-US RIDGES, HIPS,RAKES,AND GUTTER EDGES FOR STRUCTURES CRITERIA OF THE TOWN. BELOW 30'-0"MEAN ROOF HT. PROJECT INFORMATION INITIAL DATE:2/13/2018 DESIGNER:MM REV: DATE: DESIGNER: REV: DATE: DESIGNER: COVER PAGE - PV- 1 ( 2) SCALE: 1/81' - V-0" ROOF MODULE COUNT TILT AZIMUTH SHADING R1 16 37' 160° 96% R2 6 30° 249° 83% momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR SOUND AVENUE 325 HIGH STREET,METUCHEN,NJ 08840 a---- (732)902-6224 d d d d MOMENTUMSOLAR.COM p ' d STRUCTURAL ° ENGINEERING d d O d d DANIEL W.DUNZIK RA LEED-AP d p d DRIVEWAY - LICENSE#039534 p p d (908)872-3664 370 BURNT HILL ROAD A d > SKILLMAN,N)08558 d - ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND p d p d d AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& d p ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE p FRONT OF RESIDENCE - COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR 4p ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A d d 4 ° LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. p p p d dd d d ° d L /1 RCd d ° d d a NE� W DVN�i� d p ° 4 a - � r 039534 n`y0 I FIRE SETBACK OF NE ❑ I (18" VENTILATION, RIDGE 36" ROOF ACCESS) CUSTOMER a o 0 0 0 0 0 oINFORMATION ❑ MSP JEFFREY CARLSON 0 0� CB 5660 SOUND AVENUE ❑ ELECTRICAL EQUIPMENT MATTITUCK, NY,11952 R2 0 0 0 0 0 0 0 0 631-276-9176 LU ❑ JURISTICTION:SUFFOLK UTILITY:PSEGLI C=7 ❑ Rl UTILITY ACCT#:9690328501 UTILITY METER#:63129319 ❑ GUTTER PV SYSTEM" INFORMATIO_ N SYSTEM SIZE(DC):6.27 kW 22 MODULES: LONGI LR6-60 285M 22 INVERTERS:ENPHASE IQ6-60-2-US PR07ECTINFORMATION GROUND ACCESS INITIAL DATE:2/13/2018 DESIGNER:MM SOLAR INSTALLER NOTES: (NP) REV: DATE: DESIGNER: REV: DATE: DESIGNER: PANEL LAYOUT PV-2 R1 - ARRAY 1 LAYOUT DETAIL SCALE: 3/16" = 1'-0" TILT: 37' 0'-3" 19'-9" 8'-6Z" 6'-62" 3'-0" ,� momentum AZIMUTH: 160° SOLAR SHADING: 96% 1'-6" PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 0 0 0 0 0 325 HIGH STREET,METUCHEN,NJ 08840 (732)902-6224 MOMENTUMSOLAR.COM STRUCTURAL ENGINEERING DANIEL W.DUNZIK RA LEED-AP 10'-11" 10'-11" LICENSE#039534 (908)872-3664 0 0 a SKI BURNT HILI ROAD SKILLMAN,N706558 - ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL•AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. D ARc y [7'S ��W DVN 4'-7" 4'-711 SOLAR INSTALLER NOTES: "pT� �3953Q y0 OF N�� R2 - ARRAY 2 LAYOUT DETAIL CUSTOMER SCALE: 3/16" = 1'-0" INFORMATION TILT: 30* JEFFREY CARLSON AZIMUTH: 249° 5660 SOUND AVENUE 4'-12" 19'-9,. 4'-121 SHADING: 83% MA 631-2-76-9176 TTITUCK,NY, 952 JURISTICTION:SUFFOLK UTILITY: PSEGLI UTILITY ACCT#:9690328501 UTILITY METER#:63129319 0 0 0 0 0 D PV SYSTEM INFORMATION SYSTEM SIZE(DC):6.27 KW 22 MODULES:LONGI LR6-60 28SM 22 INVERTERS: ENPHASE IQ6-60-2-US 6'-1" PRO]ECTINFORMATION INITIAL DATE:2/13/2018 DESIGNER:MM REV: DATE: DESIGNER: REV: DATE: DESIGNER: LAYOUT DETAIL SOLAR INSTALLER NOTES: PV-3 22 LONGI LR6-60 285M 285W MODULES PAIRED WITH momentum 22 ENPHASE IQ6-60-2-US MICRO-INVERTERS SOLAR BRANCH CIRCUIT A EXISITING SQUARE D 200A PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 16 MICRO-INVERTERS MAIN SERVICE PANEL 240 V 325 HIGH STREET,METUCHEN,NJ 08840 BRANCH CIRCUIT B (732)902-6224 6 MICRO-INVERTERS _ STRUCTURAL MAIN BREAKER:200A INE SIDE , ENGINEERING + - + - + - HOT TAP DANIEL W.DUNZIK RA LEED-AP LICENSE#039534 (908)872-3664 ENPHASE 60A 200A 370 BURNT HILL ROAD x x AC COMBINERJSKILLMAN,NJ 08558 SQUARE-D 30A FUSIBLE ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND BOX SUNRUN METER UTILITY AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& AC DISCONNECT METER ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE g COMPLIANCE.WARNING THAT IT IS A VIOLATION OF HE LAW FOR ANY PERSON,UNLESS ACTING UNDER HE DIRECTION OF A LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY 8 3oA ELECTRICIAN O HANDLER POWER CORP ROOF 20A BREAKER(A) POWER 24 RREN HANDLER RDELL JUNCTION 20A BREAKER(B) 30A FUSES =GROUND ZEASTONOR HPORT,M7 D Q, TERMINATION CAP 1 BOX 2A-B 3 3 4 GRID \�( W Djj INSTALLED ON END OF CABLE 4. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE V� ELECTRICAL NOTES: LARGEST BRANCH CIRCUIT IN SYSTEM.OTHER BRANCH CIRCUITS -9� 03953 yOy 1.ALL CALCULATIONS FOR VOC,VMAX, IMP AND ISC HAVE BEEN WILL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN. QF N�� CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON ASHRAE 2%HIGH AND EXTREME MINIMUM TEMPERATURE COEFICIENTS. 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2014 ARTICLE 310 CUSTOMER 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 6.ALL EQUIPMENT INSTALLED IS RATED AT 90°C INFORMATION paragraph Q. THE GROUND IS CARRIED AWAY FROM THE GROUNDING LUG JEFFREY CARLSON USING #6 BARE COPPER WIRE. 7. INVERTER NOC(NOMINAL OPEN CURRENT)OBTAINED FROM 5660 SOUND AVENUE 3. THIS SYSTEM COMPLIES WITH NEC 2014 EQUIPMENT DATASHEET MATTITUCK,NY,11952 631-276-9176 JURISTICTION:SUFFOLK UTILITY: PSEGLI UTILITY ACCT#:9690328501 UTILITY METER#:63129319 PV SYSTEM INFORMATION SYSTEM SIZE(DC):6.27 KW 22 MODULES:LONGI LR6-60 285M 22 INVERTERS:ENPHASE IQ6-60-2-US Wire Tag Conduit Wire Qty W1Ce Wire Type Temp. Wire Temp. Conduit Derated Inverter NOC(A) NEC Design Ground Ground Wire Gauge Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty Correction Current(A) Size Type PROJECT INFORMATION 1 OPEN AIR 2 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 16 0.96 1.25 19.20 12 AWG Trunk Cable INITIAL DATE:2/13/2018 DESIGNER:MM REV: DATE: DESIGNER: 2A V, PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 16 0.96 1.25 19.20 08 AWG THWN-2 REV: DATE: DESIGNER: 2B 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 6 0.96 1.25 7.20 08 AWG THWN-2 ELECTRICAL 3 1" PVC 3 08 AWG THWN-2 75°C 50 0.96 1 48.00 22 0.96 1.25 26.40 08 AWG THWN-2 4 1" PVC 3 06 AWG THWN-2 75°C 65 0.96 1 62.40 22 0.96 1.25 26.40 08 AWG THWN-2 PV-4 TAG LABEL QUANTITY LOCATION NOTE EXAMPLES 1 AT EVERY SEPARATION BY momentum QA 12 DC CONDUITS ENCLOSURES/WALLS/ SOLAR PARTITIONS/CEILINGS/FLOORS OR NO MORE THAN 10' O • • • • B _ PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR PQWFR SOURCE 325 HIGH STREET,METUCHEN,NJ 08840 (732)902-6224 MOMENTUMSOLAR,COM f� r STRUCTURAL }� ENGINEERING -jJ� L ` DANIEL W.DUNZIK RA LEED-AP © 1 COMBINER BOX 1 AT ANY JUNCTION BOX OR DC �° LICENSE#039534 COMBINER IF USED O °,�i 370 BB872-3664URNTHILL ROAD 7 ! SKILLMAN,NJ 08558 • j ENGINEERING LEITER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& - - { ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR 1 ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. ` RED ASL © 1 JUNCTION BOX 1 AT ANY JUNCTION BOX OR DC �lvG\ W �rJ `A/�:. COMBINER IF USED m®a ;s�= 0 r n �A ml 1' FA��', , T 39534 Q' \ r � = OF N ESN ELECTRIC SHOCK • 1 CUSTOMER 1 OF EACH AT FUSED AC ©DISCONNECT INFORMATION OD 1 AC DISCONNECT COMPLETE VOLTAGE AND JEFFREY CARLSON 5660 SOUND AVENUE CURRENT VALUES ON DISCONNECT LABEL MATTITUCK, NY,11952 631-276-9176 JURISTICTION:SUFFOLK UTILITY:PSEGLI UTILITY ACCT#:9690328501 O UTILITY METER#:63129319 PV SYSTEM QE 1 MAIN DISCONNECT 1 OF EACH AT BUILDING MAIN —y- PANEL DISCONNECT PAN_EL �=�?' T= INFORMATION SYSTEM SIZE(DC):6.27 KW 22 MODULES:LONGI 1-116-60 285M E L: 22 INVERTERS:ENPHASE IQ6-60-2-US 1-21QK z 1 Gl"761 PROJECT INFORMATION OINITIAL DATE:2/13/2018 DESIGNER:MM Q 1 UTILITY METER 1 AT UTILITY METER REV: DATE: DESIGNER: REV: DATE: DESIGNER: EQUIPMENT LABELS PV-5 • •0' LR6-60PH 235~305W 28 , Operating NumberofCells 60(6x10) Operating Temperature-40°C-485°C � Junction Box IP68,threediodes PowerTolemnce 0-+5W components o '"^ ia. Output Cable 4mm2,1000mm in length Maximum System VoltageM DC150OV(IEC) ■■�®�� Excellent performance unI' / I I for / s Connector MC4 or compatible with MC4 Maximum Series Fuse Rating 15A 5 o.a � SFS�a 9g Weight IS2kg NOCT 45°0t2°C voltage brings,lowersystern side cost -L J ■® 4 Dimension 1650x99l x40mnn Application Class Class A Excellent PID-resistantperformance aT Packaging 26pcs per pallet ��■��� I�san temperature,i0� 1II'• .I • • • rr Type LR6-60PH-285M LR6-60PH-290M LR6-60PH-295M LR6-60PH-300M LR676OPH-305M Testing Condition i STC NOCT , STC NOCT STC NOCT STC NOCT STC NOCT Maximum Power(Pmax/W) i 285 2095 t 290 2132 ' 295 1 2168 -' 300 2205 i 305 2242I 0-year Warranty 1 i for Materials °Processin° Open Circuit Voltage(VocM 395 365 397 I 367 t 399 369 401 t 371 402 372 25-year Warranty for Extra linear Power Output0 55®/® ) 100% ■ 10 ' Short Circuit Current(Bc/A I 946 762 958 772 ! 9-69 t• 781 981 791 994 801 25-year PowerX Voltage at Maximum Power(VmpM 321 295 323 297 326 299 328 301 330 303 Warran Annual `• 888 t 710, 898 718 905 724 915 732 924 Adddlonai � �- Current at Maximum Power(Imp 1A) � i f 739 Value fr Power Attenuation < ; 09129. - _________ _______ °m LONGI golar's Linear -0 5596 w Module Efficiency(%) i 174 / 177 I 18 0 1 1 18 3 I / 18 7 / -----'--`-- --- I I Standard Mo elr of warranty 87 7% - c_______dui he '' Y'-_ STC(Standard Testing Conditions) Irradiance t000W1m2.Cell Temperature 25°C, Spectra at AM1 5 ------------------------------ ' Warran NOCT(Nominal Operating Cell Temperature) Irradiance 800W1m2.Ambient Temperature 200C, Spectra at AM1 5, Wind at 1m/S - ?Wer 845% --- --------------------"----'-�_-_----_"___- , 807% Temp.Coefficient(STICTesting Load 1 5 10 15 20 25 Temperature Coefficient of lsc -0059%/'C Maximum Front Static Load(Snow) 5400Pa Complete System and Product Certifications Positive Power Tolerance Temperature Coefficient ofVoc -0300%PC Maximum Rear Static Load Wind) 2400Pa IEC 61215,IEC 61730,UL 1703,CQC,CE 0-+5W positive tolerance of maximal power guaranteed Temperature Coefficient ofPmax -0 390%PC Pass the Hailstone Test 25mm Hailstone at the speed of 23m/s ISO 9001 2008 ISO Quality Management System High Conversion Efficiency ISO 14001 2004 150 Environment Management System The highest efficiency up to18 7% OHSA518001 2007 Occupational Health and Safety Excellent Performance in Low irradiance Outstanding power output in low irradiance conditions,such as dawn,dust Current-Voltage Curve(LR6-60PH-290M) Power-Voltage Curve(LR6-60PH-290M) Current-Voltage Curve(LR6-60PH-290M) and no-sun days 10 300 �r 2 u c 12 Nttlemh,ad-IWIN!/m 350 —YioOmth,aE•9oW:/M Anti-PID s _hKam,mmwmwim 10 ramex,:a.ioomv,N Anti-PID techniques of processing solar cells and encapsulating modules 6 —Cd luno-2sc 300 — ""°`$0" 3 6 m i^a oa —c.n luno-a,•c � _ applied,adaptable for the Installation In hot and highly humid areas € iso d 6 .<wkMa,a-ra�a„ 4 —an n�,�g,ac•'', —QbTura-ssc a 100 4 UL Adaptability to the Harsh Environments —co,t. — Excellent anti salt mist and anti-ammonia capability and Is adaptable to the 3 _c,,,,,,^,,,,c so 3 —eaa mMw.:oo~ harsh environments,such as seaside and farms °o io zo ao 4o so °o to zo 30 40 so °o io 30 so 40 Super Robust Frame,40mm Thickness voltage M voltage M voltage M -Specifications subject to technical changes and tests LONGI Solar reserves the Good pressure resistance and able to bear2400Pa wind load and 540OPa tight of final interpretation snow load N Room 201,Building 8, dlll Plaza,Lane 290, chongzhi Road, e New District,Shanghai 201203 Rd1Plaza.Lane 290. idl s New District.Shanghai.201203LONGI Solar Tel 86-21-61047332 Fax 86-21-61047377EaImeduleMongi-s Iconom LONGI Solar Tel 86-21-61047332 Fax 86-21-61047377 Email moule®longis conom Note Due to continuous technical innovation,R&D and Improvement,technical data above mentioned may be of modification accordingly LONGi Solar Note Due to continuous technical Innovation,R&D and improvement,technical data above mentioned may be of modification accordingly LONGI Solar have the sole right to make such modification at anytime without further notice, Demanding party shall request for the latest datasheet for such as contract have the sole right to make such modification at anytime without further notice, Demanding party shall request for the latest datasheet for such as contract need,and make It a consisting and binding part of lawful documentation duly signed by both parties need,and make it a consisting and binding part of lawful documentation duly signed by both parties 20170301 � r Data Sheet Enphase Mlcroinverters Enphase IQ 6 and IQ 6+ Microinverters INPUT DATA(DC) IQ6-60-2-US AND IQ6-60-5-US IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US Commonly used module pairings' 195 W-330 W+ 235 W-400 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules The high-powered smart grid-ready Maximum inpui DC voltage 46V 62V Enphase Peak power tracking voltage 27V-37V 27V-45V p Enphase IQ 6 Micro"'and Enphase IQ 6+Micro'" Operating range 16V-48V 16 V-62 V Q6 and I Q 6+ dramatically simplify the installation process while Min/Max start voltage 22V/48V 22 V i6'2 V achieving the highest efficiency for module-level Max DC short circuit current(module Isc) 15A Is A M i c r®i nve rte rs power e12CtfOfIICS. Overvoltage class DC port II II DC port backfeed under single fault 0 A 0 A Part of the Enphase IQ System,the IQ 6 and IQ PV array configuration 1 x 1 ungrounded array,No additional DC side protection required, AC side protection requires max 20A per branch circuit 6+Micro Integrate seamlessly with the Enphase OUTPUT DATA(AC) IQ6-60-2-US AND IQ6-60-5-US IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US IQ Envoy'",Enphase Q Aggregator`",Enphase IQ Peak output power 240 VA 290 VA Battery'",and the Enphase Enlighten'monitoring Maximum continuous output power 230 VA 280 VA Nominal voltage/range2 240 V/211-264 V 208 V(10)/183-229 V 240 V/211-264 V 208 V(1 m)/183-229 V and analysis software Nominal output current 0 96 A 111 A 1.17 A 1 35A The IQ 6 and IQ 6+Micro extend the reliability Nominal frequency 60 Hz 60 Hz standards set forth by previous generations and Extended frequency range 47-68 Hz 47-68 Hz Power factor at rated power 10 10 undergo over a million hours of power-on testing Maximum units per 20 A branch circuit 16(240 VAC) 13(240 VAC) Enabling Enphase to provide an Industry-leading 14(single-phase 208 VAC) 11(single-phase 208 VAC) warranty of up to 25 years Overvoltage class AC port III III AC port backfeed under single fault OA OA Power factor(adjustable) 0 7 leading .0 7 lagging 0 7 leading. 0 7 lagging EFFICIENCY @240 V @208 V(10) @240 V @208 V(14)) Easy to Install CEC weighted efficiency 970% 965% 970% 96.5% Lightweight and simple MECHANICAL DATA Ambient temperature range -40*C to+650C Faster installation with improved two-wire Relative humidity range 4%to 100%(condensing) cabling Connector type MC4 orAmphenol H4 UTX ID Built-In rapid shutdown compliant(NEC 2014) Dimensions(WxHxD) 219 mm x 191 mm x 379 mm(without bracket) Weight 1 5 kg(3 3 lbs) `=a Productive and Reliable Cooling Natural convection-No fans Approved for wet locations Yes Optimized for high powered 60-cell and 72- Pollution degree PD3 cell*modules Environmental category/UV exposure rating Outdoor-NEMA 250,type 6(11367) JQ More than a million hours of testing FEATURES Class II double-insulated enclosure Communication Power line Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Smart Grid Ready Compliance UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C222 No 1071-01 Complies with fixed power factor,voltage and This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and frequency ride-through requirements NEC-2017 section 69012 and C221-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions grid requirements 1 No enforced DC/AC ratio See the compatibility calculator at EDphase.com/en-us/supl2ort/module-compatibilit Configurable for varying grid profiles 2 Nominal voltage range can be extended beyond nominal if required by the utility U` *The IQ 6+Micro is required to support 72-cell modules To learn more about Enphase offerings,visit enphase.com E I V P H/�S E, O 2017 Enphase Energy All rights reserved All trademarks or brands used are the property of Enphase Energy,Inc C A 1 P]H A S C To learn more about Enphase offerings,visit enphase.com aJ 1 v r•� 2017-05-01 G 9 V r fl/`1J G The new EcoX is an innovative, M y� _ rail-less racking system,proven_ to organize the installation process. The flexible design - ": - offers a clean aesthetic, __ --r�e.,��•„ ,,,� , _ simplified logistics,and delivers a higher quality installation at a lower cost per watt. Aesthetic Design Cable Management ry= � `. �3 •,� kT A wide range of adjustment makes It easy to Install a Whether Installing with Mlcroinverters,Power straight,levels stem Components are designed to Optimizers,or String Inverters,EcoX provides wire 4 blend Into the array,and the aesthetic skirt creates management provisions to both prep the modules,and a finished look Alternatively,a skirt Free option Is to route homerun or trunk cables throughout the array. ` F available to provide a more traditional look /,./�• - .�..___: �£ _ -r..,r_ _ ^_� �1__ \_...— _ .. .`?.- -_ ! Layout =E2ak _ Flexible System Design Single Point Grounding The EcoX Estimator Is a powerFul racking system EcoX and approved modules create a continuously design tool The user Inputs all site conditions and bonded system The installer can connect a finished z can layout multiple roof surfaces. The EcoX Estimator array to ground with a single bonding lug outputs a site specific design package with engineering `3's r specs and bill of materials \5'_• K. 'F�.=•,;; Technical Specifications -r`,�fi}-. � `��•Y�cF,u:, ,.,�4� _;.•jig_ 'r.'�:tr•a. _ Racking components•Aluminum,stainless hardware,dark Fast. Simple. Supported. Materials bronze anodized upper surface,mill finish lower surfaces Flashings:Aluminum,black powder coated finish Modules drop In From above Universal components mount to The Ecollbrium Field support team and there is never a need to standard Framed modules.With oFfers on-site installation training Grounding/Bonding Validation UL2703-see installation manual for specific module approvals reach over or walk on modules a single socket size and a wide and ongoing technical support Fire Resistance Validation UL2703-Class A,Type 1 and Type 2 modules Pre-assembled components range oFadlustment, It is quick And From project planning to and quick connections make and easy to Install any array logistics to installation, we are Mechanical Load Validation UL2703-see installation manual For specific module approvals EcoX easy to install. with a clean, Finished look dedicated to customer service. Flashing Validation ICC-ES AC28611-11-441 Rain Test for Roof Flashing . Adjustabdlty 1"vertical range,3 5"North/South range, � connect anywhere In East/West direction `tea Warranty 15 years I� fl p,� p Y4 as sales(aiecolibnumsolarcom US 740-249-1877 wwwecolibrwmsolarcom Ec®d�brWmSolar sates(agecolibrwmsolarcom US 740-249-1877 wwwecolibriumsolarcom E ® EeodlblriumSolar