Loading...
HomeMy WebLinkAbout41975-Z O\psUfFD(,�COG Town of Southold 5/4/2018 P.O.Box 1179 0 L 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39630 Date: 5/4/2018 THIS CERTIFIES that the building BASEMENT ALTERATION Location of Property: 53930 Route 25, Southold SCTM#: 473889 Sec/Block/Lot: 61.4-19.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/13/2017 pursuant to which Building Permit No. 41975 dated 9/15/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: construct interior alterations in basement of existing commercial building(Opera House)as applied for. The certificate is issued to Olivanne LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 41975 12/5/2017 PLUMBERS CERTIFICATION DATED 6/3/2017 17 Willam Gremler .Jr. r () oh ' ignature TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE o . .SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41975 Date: 9/15/2017 Permission is hereby granted to: Olivanne LLC 53930 Main Rd PO BOX 593 Southold, NY 11971 To: construct interior alterations in basement of existing commercial building as applied for. At premises located at: 53930 Route 25, Southold SCTM #473889 Sec/Block/Lot# 61.4-19.1 Pursuant to application dated 6/13/2017 and approved by the Building Inspector. To expire on 3/17/2019. Fees: NEW COMMERCIAL, ALTERATION OR ADDITIONS $1,834.00 CO -COMMERCIAL $50.00 Total: $1,884.00 B di nspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$155..'00 6 Date. ,4 3/z Q t T New Construction: Old or Pre-existing Building: (check one) @f,5E-M E—N - Location of Property: 5 3 5 30 ll (I Roig r-) f 6 House No. Street Hamlet Owner or Owners of Property: ©l + i,t t„ ne— LL C j n Suffolk County Tax Map No 1000, Section Block ® Lot Subdivision Filed Map. Lot: Permit No. l Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ - ) Appl'cant Signatur pF SOUr�®l Town Hall Annex Telephone(631)765-1802 54375 Main Road y Fax(631)765-9502 P.O.Box 1179 �Q roger.richert(a)-town.southoId.ny.us Southold,NY 11971-0959 Q �yc®UIV�`I,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: 011ivanne LLC Address: 53930 Route 25 city,Southold st: New York zip: 11971 Building Permit#: 41975 Section- 61 Block- 4 Lot: 19.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA: Devany Electric License No: 4144-E SITE DETAILS Office Use Only Residential Indoor X Basement X Service Only Commerical X Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 16 Ceiling Fixtures 21 HID Fixtures Service 3 ph Hot Water GFCI Recpt 2 Wall Fixtures 1 Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt 1-30A Emergency Fixture Time Clocks Disconnect Switches 21 Twist Lock Exit Fixtures TVSS Other Equipment: 1- Bath Fan, 5- Combination Exit/ Emergency Lights. Notes: Inspector Signature: Date: December 5, 2017 0-Cert Electrical Compliance Form.xls SOUT�fo . Town Hall Annex Telephone(631)765-1802 54375 Main Road cn Fax(631)765-9502 P.O.Box 1179 Q Southold,NY 11971-0959 J` 6VUNTI,t� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: Building Permit No. I 1 ?5 Owner: 6-6::U?e h✓ti 1-h4 /j (Please print) 0 l Plumber: =(6&� (Please print) I certify that the solder used in the water supply system contains Iess than 2/10 of 1% lead. (PIumbers Signature) Sworn to before me this day of , 20� &A rc� D)Notary Public,_ County SEP 2 6 2017 CONNIE D.SUNCH BUMDINGDEPT. Notary Public,State of Nov York No.01BU6185050 TOWN OF SOIJTHODD puaRtled in Suffolk County Commission Expires April 14,2.Q4-�b Condon Engineering, P.C. New York State Licensed Professional Engineers 1755 Sigsbee Road 631-298-1986 Mattituck,New York 11952 Fax 631-298-2651 April 12, 2018 Mr. John Jarski Building Inspector Southold Town Building Department 54375 Main Road Southold, New York 11971 Re: Opera House in Southold Dear Mr. Jarski: I inspected the insulation in the cellar walls and the fire stopping sealing of the pipes and electrical wiring penetrations in the walls. I found the insulation installed in the cellar walls to be in accordance with the plans and the openings around pipes and wiring routed through the walls were found to be sealed where they pass through the top plate with a fire retardant sealant. If you have any questions regarding this letter, please call me at 631-298-1986. Yours truly, r. , 05iW n APR 122018 TOWN OF SOUTHOLD ti��� ypl0 a TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLRG. [ ] FOUNDATION 2ND rULATION [ ] FRAMING / STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: ilk � oviv,L�t S 4, S I � � '4- h L� DATE J01 INSPECTOR r ' • t • • t � Imo,. i • • rl C 1 ` i STATE • • r Cil r.,� �.��,►.��(l��'. ::�o�! J',�',�� � -Mwlz- MA N MA— rC _lfIMF 1 r • TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502LA 'OASurvey South oldtownny.gov PERMIT NO. S Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit - Examined '20) Single&Separate D [EC[ED'V[2 Truss Identification Form DD Storm-Water Assessment Form Contact: An nf—,T— U 6� Approved —,201] JUN 1 3 9017 Mail to: Disapproved a/c cP3 l BIJdY.I)I1S Phone: I1� P( - �o-79-1000 TOWN OF S LD Expiration ,20 B it ' g ns ctor APPLICATION FOR BUILDING PERMIT Date , 20 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate'of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name, if a corporation) �o &CZ`7141/13 �c�l' ld l 19 y l v (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder C alf AeA. — Name of owner of premises (0 (, t J A til ty E LL C (As on the tax roll or latest deed) If applicant is a corporatio , sere f duly authorized officer (Name and title of corporat officer Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. ;;' ` ' _' { 1. Location of land on which proposed work will be,done': ;( s House Number Street Hamlet Q- County Tax Map No. 1000 Section 61 Block ® Lot / , Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy SS r✓ M P)L 0 b. Intended use and occupancy Sf1 t— ASPM T _ 3. Nature of work (check which applicable): New Building Addition Alteration!-4<� Repair O'er Removal Demolition Other Work (Description) 4. Estimated Cost 3 9 .e9co c Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units ,—'INurrib,ef•of dwe-Iling-jumits`on each floor If garage, number of carsftA ( 6. If business, commercial or mixed occupancy, s'eci nature and eNtent of ea°' h type of use. p fY p• u s Yp 7. Dimensions of existing structures, if any: Front Rear 57 Depth 8,51 Height Number of Stories.' Dimensions of same struc ure with alterations or additions: Front Rear Depth - ` Height 7 ' 9'g.-Number of Stories t 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories f 9. Size of lot;Front So I ;LO �l Rear .1na Depth 10. Date of Purchase O a of S Name of Former Owner_ 9 ULLVC) ur)CLL ( WW C� 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NQS 13. Will lot be re-graded? YES NO1�4WHI excess fill be removed from premises? YES NO 14. Names of Owner of premises oz. UaW tko- W, AddressS333C0 ilCi W �GYti�Phone No.X31 kSloM� Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property;within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. � � & _ 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on qurvey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) nn SS: COUNTY OF S �C ®�i 1JQVt Vl2 h�^ be±9t4t(s)he is the applicant (Name of individual signing contract)above named, (S)He is the (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the applicatiofqfAek* a ER NOTARY PUBLIC,STATE 00 NEW YORK Sworn to before me this NO.01 DW6306900 ��—�' day of,)U 1'�` 2 SION EXP RES JU E COUNTY �hAI.S30,2_Q& otary Public Q Signat re of Applicant � I 3��OF Si7�jry [EZ ' i E J D Town Hall Annex Telephone(631 180 4 201 54375 Main Road ) 61- Q2 P.O.Box 1179 Gs ` roner.dchertd-oWtl l$out�oltl.nY us Southold,NY 11971-0959 dry TO AWN OF SOUrHOLD j BUILDING DEPA R TMEW TOWN OF SOUTHOLD � Af'P..ICATION FOR ELECTRICAL INSPECT19N REQUESTED BY: 1`nl�� Dingy Date: Company Name: evaA Name: license No.: L- Address: Phone No.: S I tom-- C/43 - 1.1'X'( 1 JOBSITE INFORMATION: (*indicates required information) *Name: (5 L1- n n� 1^L C- VG_ *Address: *Cross Street: I- t *Phone No.: Permit NG.: y 19 -7 Tax-Map District: 1000 . Section: r: ). Block:_ Lot: 1a. *BRIEF DESCRIPTION OF WORK(Please Print Clearly) (Please Circle All That Apply) Is job ready for inspection: ES NO Rough In incl *Do-you need a Temp Certificate: YES Temp information (lf.needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 4i " B24;hWest for lnspectlon Form U Ivafj 0104 Qo� ► / CERTIFIED TO: �e. '� �® OLIVANNE, LLC THE BRIDGEHAMPT01 STEWART TITLE INSUI BRIDGE ABSTRACT ck 3. UN N 60 Pq ��y, �N �' � �r�•3� �"- ��G r� GES°' G P r � PK ��9 �A�Z ►l�sc5 �G Pp Re 60 VO AN \+ +v s�-0 Ott �N 50-1 +\ � 5y. G ae, p 03- +mol �' COMcheck Software Verso®n 4"0.602 Envelope Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: Southold Opera House Location: Southold, New York Climate Zone: 4a Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 53930 Main Road Anne Julia Audray John J.Condon Southold, NY P.O. Box 593 Condon Engineering Southold,NY 11971 1755 Sigsbee Road Mattituck, NY 11952 631-298-1986 condoneng@optonline.net Building Area Floor Area 1-Performing Arts Theater:Nonresidential 3252 Envelope Assemblies R-Value Proposed Max.Allowed Post-Alteration Assembly Cavity Cont. U-Factor SHGC U-Factor SHGC Basement Wall 1:Solid Concrete:8"Thickness,Furring:Wood, 15.0 0.0 0.072 — 0.108 — Wall Ht 8.0,Depth B.G.6.0,[Bldg.Use 1 -Performing Arts Theater] Envelope Compliance Statement Compliance Statement. The proposed envelope alteration project represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.6.2 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title Sig Date Project Title: Southold Opera House Report date: 09/14/17 Data filename: C:\Users�john Condon\Favorites\ComChecks\53930 Main Road.cck Page 1 of 8 Condon Engineering, P.C. New York State Licensed Professional Engineers 1755 Sigsbee Road 631-298-1986 Nlattituck, New York 11952 Fax 631-298-2651 condonengineering.com DD September 4, 2017 " S E P 1 1 2017 Mr. Mike Verity auuuj-,iNGMPT. Chief Building Inspector TOWN OF SOUTHOLD Southold Town Building Department 53095 Route 25 P.O. Box 1179 Southold, New York 11971 Re: Southold Opera House 53930 Main Road Dear Mr. Verity: The walls separating the storage spaces from the rest of the spaces in the cellar are to be clad on both sides with 5/8"thick fire rated gypsum board in accordance with UL Design No. U305 which has a 1 hour fire rating. All of the spaces are also equipped with automatic fire sprinklers. If you have any questions, please call me at 631-298-1986. Yours truly, Cond P.E. 2x6 Studs Fire Stopped 16" 5/8"Thick Fire Rated Gypsum Board 3 1 2 1. Nail heads-Exposed or covered with point compound. 2. Joints-Exposed or covered with fiber tape and joint compound. 3. Wall board nailed 7"OC with 6d cement coated nails 1-7/8"long,0.0915 shank diam, 1/4"diam heads. 4. Wallboard,Gypsum-5/8"thick,two layers applied either horizontally or vertically. Inner layer attached to studs with the 1-7/8"long nails spaced 7"OC. Outer layer attached to studs over inner layer with the 2-3/8"long nails spaced 8"o.c. Vertical joints located over studs. All joints in face layers staggered with joints in base layers. Joints of each base layer offset with joints of base layer on opposite side. 1 Hour Wall Detail UL Design No. U305 COMcheck Software Version 4.0.6.2 Envelope Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: Southold Opera House Location: Southold, New York Climate Zone: 4a Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 53930 Main Road Anne-Julia Audray John J.Condon Southold, NY P.O. Box 593 Condon Engineering Southold, NY 11971 1755 Sigsbee Road Mattituck, NY 11952 631-298-1986 condoneng@optoniine.net Building Area Floor Area 1-Performing Arts Theater: Nonresidential 3252 Envelope Assemblies R-Value Proposed Max.Allowed Post-Alteration Assembly Cavity Cont. U-Factor SHGC U-Factor SHGC Basement Wall 1:Solid Concrete:8"Thickness,Furring:Wood, 15.0 0.0 0.072 — 0.108 — Wall Ht 8.0,Depth B.G.6.0,[Bldg.Use 1 -Performing Arts Theater] Envelope Compliance Statement Compliance Statement. The proposed envelope alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.6.2 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. -575I9-14tf'7 Name-Title Sig Date Project Title: Southold Opera House Report date: 09/14/17 Data filename: C:\UsersVohn Condon\Favorites\ComChecks\53930 Main Road.cck Page 1 of 8 M Studs Fire Stopped 16" 5/8"Thick Fire Rated Gypsum Board 3 1 2 1. Nail heads-Exposed or covered with joint compound. 2. Joints-Exposed or covered with fiber tape and joint compound. 3. Wall board nailed 7"OC with 6d cement coated nails 1-7/8"long, 0.0915 shank diam, 1/4"diam heads. 4 Wallboard,Gypsum-5/8"thick,two layers applied either horizontally or vertically. Inner layer attached to studs with the 1-7/8"long nails spaced 7"OC. Outer layer attached to studs over inner layer with the 2-3/8"long nails spaced 8"o.c. Vertical joints located over studs. All points in face layers staggered with joints in base layers. Joints of each base layer offset with joints of base layer on opposite side 1 Hour Wall Detail UL Design No. U305 SURVEY OF PROPERTY N A T SOUTHOLD TOWN 'OF SOUTHOLD SUFFOLK COUNTY, N. Y, 1000-61-04-19.1 SCALE.• 1'=30' AUGUST 27, 2007 JUNE 30, 2015 tee. �t• / CERTIFIED TO: OLIVANNE, LLC THE BRIDGEHAMPTON NATIONAL BANK g EPp v�R \� STEWART TITLE INSURANCE BRIDGE ABSTRACT COMPANY . '510- ,00'•0 Q / / P� �pm P R o 16 o A. _. �, . •� SAE N_ o p016 a,G 4.5 P AO Rf0 '� O � � �• �y�o �'��/ 1 G pG �'0 N / 'A7� G Gd'c� �QO f 00 G O G 0 o \ \+ a f �5�� I � f 10 ooE garJN V0\5 R®"�"i 5�1 Ax1 ® = REBAR �`pGnsoFE CER77FIED T0: EA SOUTHOLD UNI TED METHODIST CHURCH FIRST AMERICAN 777LE INSURANCE COMPANY + i OF NEW YORK i AREA=50 206 SQ. FT. nY 1. Pf4 ANY ALTERA710N OR ADD1710N .TO THIS SURVEY IS A VIOLATION --,64YS. LIC. NO. 49611 OF SECTION 72090F THE NEW YORK STATE EDUCATION LAW. ECONIC ORS, P.C. EXCEPT AS PER SEC7ION 7209-SUBDIVISION 2. ALL CER77FICA77ONS (631) 765-5020 FAX (631) 755-1737 HEREON ARE VALID^FOR^THIS MAP AND COPIES THEREOF ONLY IF,A^ P.O. BOX 909 NOTES: WINDOW " OCCUPANCY 101 (MUSIC STUDIO) 5 OCCUPANCY 102 (WAITING AREA) 15 OCCUPANCY 112 AND 109 (REHEARSAL f EXISTING EXISTING STUDIO+ DRESSING ROOM) 40 WINDOW • WINDOW OCCUPANCY 103 (STORAGE INSTRUMENTS) •� OCCUPANCY 110 (STORAGE) i MECHANICAL EXISTING - ALL INTERIOR WALLS ARE COVERED B VENT BRICK FOOTING "' 5"/8" SHEETROCK BOTH SIDES WITH 6 X 6 GIRDER APP VEDAS NOTEDIN ACCORDANCE WITH UL 305 UP i _ 4'-0" I _ "' DATE: B.P. �� - -- - '` BY: FIRE EXTINGUISHER-CLASS ABC, 21/21b HW UTI LITY _ FEE: AMEREX Model S-9872 _ EXIS EXISTING t g` NOTIFY BUILDING DEPART .NT AT 1_L1 % 11 o „ 765-1802 8 AM TO 4 PM FOR THE - ---_— WINDOW I DOOR / C 5/8 TYPE X HANDRAIL, _ 2 Boilers: 175.000 to 200.000 BTUs each SHEETROCK ; FOLLOWING INSPECTIONS: ' THROUGH OUT 1. FOUNDATION - TWO REQUIRED EXISTING o `� FOR POURED CONCRETE —? aIr � CRAWL SPACE i 2. ROUGH - FRAMIiI a & PLUMBING JOHN CONDOM i EXISTING '1 i BOILER EOIL]ER COLUMN i "' 3. INSULATIC" ,3 \ ALL EXISTING ; .JN MUST DUTCH WALL 4. FINAL - ENGINEERING P.0 4 - - - - - - - - - 3068 -= — - BE COMrL:. , C.O. EXISTING EXISTING 10 ALL CONST C"� SHALL MEET THE 631-298-1986 DUTCHEXISTING L DUTCH WALL COLUMN la ( REQUIREMEN OF THE CODES OF NEW i I YORK STATE. NOT RESPONSIBLE FOR MATTITUCK, NY 11952 • EXISTING , DESIGN OR CONSTRUCTION ERRORS. ti FIRE 1XHR FIRE—RATED CHIMNEY i EXTINGUISHER DOOR AND ASSEMBLY 103 i WITH SELF—CLOSING '� � Dcrr I 01- HINGES - - 3 00 COMPLY WITH ALL CODES O - EXISTING UF' I INSTRUMENTS STORAGE o NEW YORK STATE & TOWN CODE 3 CEILING HEIGHT 7'8" DUTCH WALL EXISTING i x ? AS REQUIRED AND CONDITIONSE 1F UJ o _ COLUMN i NOT A PUBLIC SPACE `�' 3 _ E(� LAJ C! "s o � � CEI , „ ,���, ,,p, .-��.f � },. :• DRESSING -- -- - FIRE I LING HEIGHT S G _ EXISTING STORAGE 3 XTINGUISHER I '�`R�' ,,. {° ___-7'k - — 109 _ tXIS11NG 3 - COLUMN COLUMN - N.Y.S.DEC NOT A PUBLIC SPACE 'y CEILING HEIGHT 7'6" I 3068 EXIT r 0 EXIT * 1684- N 3068 DRYER EXISTING FIRE COLUMN ,.w Y... • c VENT _ -, 00 EXISTING EXTINGUISHER ----{ k ✓CU+PANCY OR DUTCH WALL WITH ARROW -- ` - — — 6. - �E IS UNLAWFUL. a0 oo PROJECT, ❑ DRESSING � °"�'"G IsT,NG J� �' - Q � I � •• 8 � `ITHOUT CERTIFICATE COLUMN COLUMN BATH F OCCUPANCY 53930 MAIN ROAD (`2/}---- EXISTING _ C� �-_® ' �s�o�M, �� o �ETr,lr� STaM WTE�Rur�oF� FORMER METHODIST CHURCH COLUMN L� U N D RY o a 1 105 I T ' BATH \\ / w BM :� PURSUANT TO CHAPTER 236 SOUTHOLD, NY 11971 I � gs- , ►06 y �, OF THE TOWN CODE. ' CEILING HEIGHT 7'8" 631-657-0766 Z I rn �� 0 o o / ELECTRICAL. co °o ►. °o / 6i INSPECTION REQUIRED M REVISIONS: i EXISTING COLUMN o TRUSS PRACARD,NG REQUIRED REHEARSAL STUDIO Exir - �pSR-_ FOR REVIEW E 0 / 112 o CEILING HEIGHT 7'8" I L11 PLUMBER,CERTIFICATION CEILING HEIGHT 7'6" z � FIRE EXTINGUISHER WITRARROW .p ON LEAD CONTENT BEFORE _ _ _ _ _ 3 6 8 CERTIFICATE OF OCCUPANT, Q EXIT 6 SOLDER USED IN WATER - SUPPLY SYSTEM CANNOT O-- FIRE ^, EXCEED-2 t 6 OF"1%LEAD. Q rn EXTINGUISHER CO Q I • EXISTING PLUMBING WAIITING AREA COLUMN MUSIC STUDIO ' I Q � i ALL PLUMBING WASTE 102 101 t° (4 WATER LINES NEED o No All , , I - x �+ Z Q TSTIIvG BEFORE COVER!!1G Q CEILING HEIGHT 7 8 •� 0 5 EXISTING EXISTING EXISTING EXISTING I CEILING HEIGHT 7'8" w 3 WINDOW WINDOW WINDOW WINDOW Bi eye oor ctwork DATE: _ 0,910/2017 ,sting r aired. SCALEI DRAWN BY: / FIDE INSPECTION CHECKED BY.- REQUIRED Y: REQUIRED BEFORE '`. EXISTING EXISTING OPENING WINDOW WINDOW 12'-7" 1T-2' 16'-5' x6 Studs Fire Stopped 16'-7' 15-7 y'. 16" DRAWING TITLE, !8"Thick Fire Rated Gypsum Board PROPOSED BASEMENT CC D 1,_0 V-0r A B 44'-9" 33'-7' 3 1 2 79'-1* 1. Nail heads-Exposed or covered with joint compound. 2. Joints-Exposed or covered with fiber tape and joint compound. DRAWING NUMBER: 131 r 3. Wall board nailed 7"OC with 6d cement coated nails 1-7/8"long,0.0915 shank diam, 1/4"diam heads. h ' 4. Wallboard,Gypsum-5/8"thick,two layers applied either horizontally or vertically. Inner layer attached to Sp 1 I 1 studs with the 1-7/8 long nails spaced 7 OC. Outer layer attached to studs over inner layer with the 2-3/8"long 1 n nails spaced 8"o.c. Vertical joints located over studs. All joints in face layers staggered with joints in base S C� I'Lt I A) RA 4a n layers. Joints of each base layer offset with joints of base layer on opposite side. SH =2 I=fi�O�Osi'� 3,�51"iNlt F 1 Hour Wall Detail /� UL Design No. U305