Loading...
HomeMy WebLinkAbout42159-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE V . a SOUTHOLD, NY Vo BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 42159 Date: 11/20/2017 Permission is hereby granted to: Petty, Emeline & Bryan c/o Bryan Spencer Petty PO BOX 87 Peconic, NY 11958 To: install roof mounted solar panels as applied for. At premises located at: 520 Track Ave, Cutchogue SCTM # 473889 Sec/Block/Lot# 103.-12-4 Pursuant to application dated 11/9/2017 and approved by the Building Inspector. To expire on 5/22/2019. Fees: SOLAR PANELS $50.00 CO -ALTERATION TO DWELLING $50.00 ELECTRIC $100.00 To al: $200.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 1 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 //7 Date. 7 New Construction: Old or Pre-existing Building: ✓ (check one) Location of Property: 50'W -rroic k Ave, 6 c jqo v e- House No. Street H let Owner or Owners of Property: 61-I clk,n ye'y�� Suffolk County Tax Map No 1000, Section Block Lot Subdivision { C- V Filed Map. Lot: Permit No. Date of Permit. Applicant: Cawyron Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ J Applicant Signature Pontino, Susan From: Jonathan Pagano <JPagano@MomentumSolar.com> Sent: Wednesday,January 10, 2018 12:30 PM To: Pontino, Susan Subject: Void Solar Permit Good afternoon Susan, This is Jon from momentum solar, we just spoke on the phone a few minutes ago. Can we please have the solar permit application for 520 Track Ave. Cutchogue, NY 11935 voided out,this project ended up being canceled by the customer due to personal reasons. The home owners name is Bryan Petty. Thank you and have a great rest of your day, Jonathan Pagano Long Island Permit Coordinator ®momentum SOLAR 45 Fairchild Avenue Plainview,NY, 11803 631.536.4100 Ext.968 www.momentumsolar.com The content of this email is confidential and intended for the recipient(s) specified in this message. It is forbidden to share any part of this message with any third party, without a written consent of the sender. If you received this message by mistake, please reply to this message and follow with its deletion, so that we can ensure such a mistake does not occur in the future. 1 , FIELD TNSYECI"XP.zpoxr DATA CO 9 FOUrmASON;(1ST) FOUND, ,MON(2ND) ROUGH FRA4N�& PLUNMING • INSULATION PEA N.Y. G H STATE ENERGY COHSE r% FINAL 1.0 is ... .. ' . ALD I D rT, R i ' b TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX: (631) 765-9502 Survey Southoldtownny.gov PERMIT NO. `"T 1 / Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined '20 Single&Separate Truss Identification Form Storm-Water Assessment Form ZdContact: Approved ,20 Mail to: 45 Fa i rchi 14 AV Q. DD Disapproved a/c n a I h V i l✓W, NY l l b'Q 3 -S✓�`fe D Phone: 63J-!9;6-Y100 e x 4 'T62 Expiration -'20 Building Inspector D IECIE51V'R APPLICATION.FOR BUILDING PERMIT NOV 9 2017 Date hlode�� rid ' D , 20� INSTRUCTIONS BVtLTPM1DHR1R4UST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets 0fdWN-0F60&=%Ao scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Butldmg Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. I ( f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations, for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. 4 l (Signature of applicant or name,if a corporation) i5 PwMd live• P�ai t1W ewe 6!y 11103 'g (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer general contrac , electrician,plumber or builder 6,ene-r'c4.\ C©/i -I`aG�Dr- p Name of owner of premises an (As A the tax roll or latest deed) If applicant is a corpo n, signaWe of d1ily authorized officer (Name and title of corporate officer) Builders License No. S 75 7 — I Plumbers License No. NJA Electricians License No. 3 Other Trade's License No. N /} 1. Location of land on which proposed work will be done: 5�0 10 CK Ave , /-Oft A00 V e House Number Street fifirniet !� County Tax Map No. 1000 Section 103 Block /A Lot / Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended a and occupancy of propose(}construction: a. Existing use and occupancy r1R ' Fol N 1 I V eG r — Rovn d P,510 en Ce b. Intended use and occupancy So to-r a yAeA S 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work S o L CA r r2c, -w-L S U (Description) 4. Estimated Cost -I 1 5 • Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO 7\ 13. Will lot be re-graded? YES NO �— Will excess fill be removed from premises?YES NO /� 92-0 -Pra CK Ove, � 14. Names of Owner of premises ar) Pe 41 Address Cvfch o y Pe,my IMSE Phone No. G 3/—73 y_53 23 Name of Architect No,e 1)vv12i k. AddressM946 PhoneN.o 0 —879— �Y Name of Contractor e1-a^v1-Y,rnr-7 Address V5 Yrq');1-,chi'W,4V0 Phone No. 63/— —-'/l D c� `ainylew Nr 11fd3 n 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF 54 Cil r'`e rbh Cry/i PC7V(16`) being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Ze/'�r-zu-hor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn tq before me this 2�' day of V 20_ THOMAS R. MANSFIELD Notary Public BLIC,STATE 0 Signature of Applicant No.01 MA6357321 pp QUALIFIED IN SUFFOLK COUNTY MY COMMISSION EXPIRES APRIL 17,2021 i pf SOtllyolo . Town Hall Annex 11 Telephone(631)765-1802 is 54375 Main Road cn m�ax(631)765-995pp22 P.O.Sox 1179 G� Q roger-richert(cytown.southold nV us Southold,NY 11971-0959 �O lyComm,�� I I BUILDING DEPARTMENT TOWN OF SOUTHOLD ! APPLICATION FOR ELECTRICAL INSPECTION i n I REQUESTED BY: �p 1 Ol Q n p Date: Company Narne: e/j `Y) 50 1 Ot r Name: License No.: 57578 — 4 !. Address: 45Fcarrk,` vt?. �aI01 vrew , Y /lgd _S/jW Phone No.: D JOBSITE INFORMATION: (*Indicates required information) *Name: B� a el Pei� *Address: SaO I rot c All 6t/ EG.t on vp , /v ll j *Cross Street: 5�1I 1yot� er *Phone No_: Permit No.: 5 Tax-Map District: 1000 Section: D Block: /01 Lot: I *BRIEF DESCRIPTION OF WORK (Please Print Clearly) 5o lq` Pc�,-L e / r'/► G,�' dr� (Please Circle All That Apply) *Is job.ready for inspection: YES/0 Rough In Final *CSO you need a Temp Certificate: g§ ! NO Temp Information (if-needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION I - .82-Request for Inspection Form I r A MJFMFNT,CQNTRACIQSrS'- } ' . SUFFOLK•COUNTY bEPT ORLABOR. i �HOME'IMPROVEMENT-,SALESPERSON dK. UCENSINO B CQNSUMER AFFAIRS,__ LICENSEE HOM IMPROVE ENT N80W.CAMERON-CHRISTENSEN CONTRACTORLICENSE - t�rx k G.s t'r 3License t,2ow2"CAMAN d" CAMERON CHRISTENSON Ezptre9on Oats:Feb 28;2017 ,c This certifies that the bearer is duty PRO CUSTOM SOLAR LLC DBA licensed by the _ County ofSuifolk �u"""Y'~ W08/2016 „ •11269-*2016-Ax1s• 5757&H e...we.a., awunaMa» 1rUMmiR 16 YORK Workers' CERTIFICATE OF STATE Compensation Board NYS WORKERS'COMPENSATION INSURANCE COVERAGE 1 a.Legal Name 8 Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Pro Custom Solar LLC 732-902-6224 DBA Momentum Solar 45 Fairchild Avenue,Suite B Plainview.NY 11803 1 c,NYS Unemployment IEm b Registration Number of Insurance Employer Insured Work Location of Insured(Only required if coverage is Veciilcally limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 271242539 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Cartier (Entity Being Listed as the Certificate Holden New York Marine&Gen Ins Co Town of Southampton Licensing Review Board Hampton Rd 3b.Policy Number of Entity Listed In Box"l a" 116 Hampton 116 WC201600012773 Southampton,NY 11968 3e.Policy effective period 12/122016 to 12H2/2017 3d.The Proprietor,Partners or Executive Officers are ❑X Included.(Only check box if all penners/ottleere included) ❑ all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box'1 a°for workers' compensation under the New York State Workers'Compensation Law.(To use this forth,New York(NY)must be listed under item 3A on the INFORMATION PAGE of the workers'compensation Insurance policy). The Insurance Carver or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". Will the carrier notify the certificate holder within 10 days of a policy being cancelled for non-payment of premium or within 30 days if cancelled for any other reason or if the insured is otherwise eliminated from the coverage indicated on this certificate prior to the end of the policy effective period? ❑YES E❑NO This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect Please Note:Upon cancellation of the workers'compensation policy indicated on this form,If the business continues to be named on a permit,license or contract Issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business Is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the Insurance carrier referenced above and that the named Insured has the coverage:s,d 1 on thiform. Approved by (Print name of authorized iepi entativeortbeenWAaefdoM comer) yl Approved by ` l �Q (Signature) Title: 1 'r A N^ Telephone Number of authorized re resentative:or licensed agent of insurance carrier P P 9 Please Note:Only Insurance carriers and their licensed agents are authorized to Issue Forth C-105.2.Insurance brokers are 1�QI authorized to Issue It C-105.2(9-15) www.wcb.ny.gov PDF created with pdfFactory trial version www.odffactory.com c7 Workers' CERTIFICATE OF INSURANCE COVERAGE ATE Compensation Board UNDER THE NYS DISABILITY BENEFITS LAW PART 1. To be completed by Disability Benefits Carrier or Licensed Insurance Agent of that Carrier 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured (732)902-6224 PRO CUSTOM SOLAR LLC DBA MOMENTUM SOLAR 1 c.NYS Unemployment Insurance Employer Registration Number of 45 FAIRCHILD AVE SUITE B Insured PLAINVIEW,NY 11803 Work Location of Insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 271-24-2539 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) New York State Insurance Fund(NYSIF) 3b.Policy Number of Entity Listed in Box"1 a" TOWN OF SOUTHAMPTON DBL 6824 29-7 116 NY-27A(116 HAMPTON ROAD) SOUTHAMPTON,NY 11968 3c.Policy effective period 12/14/2016 to 12/14/2017 4.Policy covers: ® A.All of the employer's employees eligible under the New York Disability Benefits Law ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability Benefits insurance coverage as described above. Date Signed 7/27/2017 By �-:—;;I" -110z---:- Joseph J.Masi (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number(866)697-4332 Title Director of NYSIF Disablltty Benefits Insurance IMPORTANT If Box"4a"is checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mal it directly to the certificate holder. If Box"4b"is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the Disability Benefits Law.It must be mailed for completion to the Workers'Compensation Board,DB Plans Acceptance Unit,328 State Street,Schenectady,NY 12305 PART 2.To be completed by the NYS Workers'Compensation Board(Only If Box"4b"of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability Benefits Law with respect to all of his/her employees. Date Signed By Signature of NYS Workers Compensation Board Employee) Telephone Number Title Please Note: Only insurance carriers licensed to write NYS disability benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to Issue this form. DB-120.1 (9-15) Certificate Number 444643 PDF created with pdfFactory trial version www.pdffactory.com PROCU-1 OP ID:LM ACORO' CERTIFICATE OF LIABILITY INSURANCE FDATE(M 07/27/2/201177 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: H the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Brown 8,Brown Insurance NAME: Lisa MacDonald 2000 Midlantic Dr.-Suite 440 AHICdo Ext:732-504-2001 AIC No):732-504-2011 Mount Laurel,NJ 08054 ADDRESS:Brian DlLulgl SS:Imacdonald@bbdvins.com INSURER(S)AFFORDING COVERAGE I NAIC p INSURER A:New York Marine 8:Gen Ins Co 116608 INSURED Pro Custom Solar LLC INSURER B:Lloyd's DBA Momentum Solar 45 Fairchild Avenue,Suite B INSURER C:Hiscox Insurance Company Inc 110200 Plainview,NY 11803 INSURER D: INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE POLICY EFF POLICY EXP LIMBS LTR POLICY NUMBER MM/DD MMMD B X I COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,00 DAMAGE TO RENTED CLAIMS-MADE F5(]OCCUR GL201600007987 12/12/2016 12/12/2017 PREMISES Ea occurrence $ 100,00 C NE1860007.16 1210112016 12/01/2017 MED EXP(Any one person) $ 5,00 X Professional Liab CLAIMS MADE PERSONAL&ADV INJURY $ 1,000,00 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,00 POLICY❑JECT r—]LOCPRODUCTS-COMP/OP AGG $ 2,000,00 OTHER: PROF $ 1,000,00 AUTOMOBILE LIABILITY Ea COMBINED SINGLE LIMIT $ 1,000,00 A X ANY AUTOU201700012651 04/21/2017 04/21/2018 BODILY INJURY(Per person) $ ALL OWNED SCHEDULED AUTOS AUTOS BODILY INJURY(Per acddeM) $ X HIRED AUTOS X NON-OWNED PROPERTY DAMAGE $ AUTOS Per..dderd $ X 1 UMBRELLA LIAR OCCUR EACH OCCURRENCE $ 5,000,00 B 1 EXCESS LIUB CLAIMS-MADE UM201600004884 12/12/2016 12/12/2017 AGGREGATE $ 5,000,00 DED I I RETENTIONS $ WORKERS COMPENSATION X 1 PER - AND EMPLOYERS'LIABILITY STATUTE ER A ANY PROPRIETOR/PARTNER/EXECUTIVE Y/N 0201600012773 12/12/2016 12/12/2017 E.L.EACH ACCIDENT $ 1,000,00 OFFICER/MEMBER EXCLUDED? Fi�]N I A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,00 If Yes describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,00 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached H more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Southampton THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Licensing Review Board 116 NY-27A 116 Hampton Rd AUTHORIZED REPRESENTATIVE Southampton,NY 11968 ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD APPROVED AS NOTED er,;,yj 'r `�s Vl,, H �J.Jv_CDD ES OF � �N CODES 'c'A �I'{i!! 'E & TOU1, DATE: �( ` 20-1it B.P.# 42-1 � NEIN YC�:�,S :� � ,fie In r^nn;tJ;z't�r AS REQUIR: �__ NOTIFY BUILDING DEPA i AENT AT 765-1802 8 AM TO 4 PM FOR THE ��I17N rF-, !��`•�ai ain! ' D FOLLOWING INSPECTIONS: - -�- 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C 0. OCCUPANCY OR ALL CONSTRUCTION SHALL MEET THEOFTHE ES OF NEWt � i1 REQUIREMENTS NOT RESPONSIBLLE FOR USE IS "NLr ��� YORK DESIGN OR CONSTRUCTION ERRORS. WITHOUT CERTIFICAI t ELECTRICAL 1®F OCCUPP,%i CY INSPECTION REQUIRE® Daniel W. Dunzik Architect LEED-AP Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd.Skillman, NJ.08558 908-872-3664 370 Burnt Hill Rd. Skillman, NJ.08558 908-872-3664 October 30,2017 panels shall be designed to support in excess of 30 lb. snow load by the manufacturer. Solar panels do not add any additional snow load to the existing structure. Refer to manufacturers \Township of Southold specifications. 53095 Route 25 Southold,NY 11971 4. All penetrations shall be completely water tight and guaranteed for a period of ten years or the duration of the existing roof warrantee whichever is longer. Attn: Construction Official Re: Proposed Photovoltaic Solar Panel Installation 5. Positive drainage of the system shall be provided so as to not void the existing roof Bryan Petty warrantee. 520 Track Ave. Cutchogue NY 11935 6. All attachment system components shall be manufactured by"Eco-Fasten Inc."All Dear Sir: attachment system design is based on manufacturers printed design specifications. All aspects Regarding the solar panel array installation on the above referenced project please note that of this design shall be installed in strict compliance with manufacturers printed specifications. A visual inspection was performed and analysis of the existing structure was conducted.There is adequate structural capacity for the installation of the array with the following 7. All aspects of the installation shall comply with the 2015-International Residential recommendations: Code,the 2016-New York State Uniform Code Supplement,all local Code and ordinances,2014 National Electric Code NFPA 70/2014, Weathering Severe, Wind 1. The array will be installed on the existing roof. The roof is constructed of 2"x6"wood rafters Exposure Category B,Climate Zone 4A. @ 16" O.C. spanning 14'4" max. up the slope with 2"x4"collar ties @ 48" O.C. and 1/2" plywood sheathing. The new array(See Site map by contractor) will add 2.63 Lb. /Sf. overall If you have any uestions relating to this matter,please contact me at your earliest to the roof. No additional structural support is required for the existing roof structure. conveme �) 2. The system shall be secured to the roof using the"Ecolibrium Solar""Eco-X"®attachment �� oP`� DU"V�• TFC, system. The attachment system shall be UL 1703 approved tested. The attachments shall be min. 5/16"x 4" long stainless steel lags with a min. embedment of 2" into the rafters. When ��Qa mounted in landscape or portrait attachments shall be spaced @ 48"o.c. max. with each row staggered in roof wind zone 1. Attachments shall be spaced @ 32"o.c. max. in wind zone 2& �;�„ 3. The maximum panel cantilever length shall be 16" in wind zone 1,2, &3 except when � 039534 mounted in portrait the maximum cantilever length shall be 12" in wind zone 3 only. Provide 6 TF mil. vapor barrier between dissimilar metal fasteners. Provide water tight gasket and sealant at Daniel W. 1 ED-AP all penetrations. Attachments shall follow panel rows as specified by the system Lic.No. 039534 manufacturer's installation manual. The panel angle shall match the roof slope. Structural Design Loads: -Dead Loads= 10psf(+2.6psf,New Solar Panels)= 12.6psf. - Snow Loads=30psf(24.5psf- factored per ASCE 7-10),Climate Zone 4A - *Wind loads= 130mph wind speed Exposure B {zones 1,2&3(+/-)= 13psf, zone 1(-)_- 21.3psf, zone 2(-)_ -35.6psf,zone 3(-)_-48psf} *Wind loads per ASCE 7-10. (-) _-35.6psf, zone 3(-)_-48) *Wind loads per ASCE 7-10. 3. Solar modules shall be secured to the roof as per the manufacturer's specifications. Solar modules shall be UL-1701 rated or better. Solar Panels and attachment system shall be designed by the manufacturer to withstand winds in excess of 130 MPH. and 50.0 PSF. Solar PLAN KEY SYSTEM INFORMATION (M momentum COVER PAGE MODULE RECOM RCM-280-6MB momentum PV-1(1) COVER PAGE CONT. INVERTER ENPHASE IQ6-60-2-US SOLAR PV-2 PANEL LAYOUT RACKING ECOLIBRIUM ECO X RAIL-LESS SYSTEM _ PV-3 LAYOUT DETAIL PRO 325 HIGH STREETUSTOM SOLAR LLCMETUC ENMN]08B40 SYSTEM SIZE (DC) 14.56 KW (732) 0LAR 902-6224 PV-4 ELECTRICAL MOMENTUMSOLAR.COM PV-5 EQUIPMENT LABELS LOCATION 41.01229297, -72.47322897 STRUCTURAL ENGINEERING GENERAL NOTES: DANIEL W.DUNZIK RA LEED-AP LICENSE M 039534 (908)872-3664 370 BURNT HILL ROAD SYMBOL LEGEND THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS SKILLMAN,N]0855ENG8 FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-10, IRC 2015 AND NEW AND LOAD NEERING UL LOAD CA CULAnOS FOR SOLAR INSTALLATION SPASTTACHED HAS SPECIFICATIONS FOR gND YORK STATE UCS 2016 NEC 2014 AND ALL LOCAL CODES &ORDINANCES. ATTACHMENTS WARNINGO MEET THATLOCAIT IS STATEBUILDINGOF THE LAW FOR MSP MAIN SERVICE PANEL ® CHIMNEY ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A Fms]P AN 18" WIDE (FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED ALONG AT LEAST LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY SP SUB-PANEL SKYLIGHT ONE SIDE OF THE ROOF ON THE SAME SIDE AS THE SOLAR EQUIPMENT OR ON ANOTHER SIDE OF THE RIDGE THAT DOES NOT HAVE SOLAR EQUIPMENT ON IT. IN FtED ARCS, ADDITION AN 18" WIDE PATHWAY(FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED 5 w p �j G UTILITY METER ® VENT FROM AT LEAST ONE EAVE. �4ij o AC AC DISCONNECT OPIPE VENT ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE °A Dc SOLAR EQUIPMENT. uoc UTILITY DISCONNECT FAN INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND N NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. LC LOAD CENTER SATELLITE DISH �T� 039534 �O WEIGHT OF THE INSTALLED SYSTEM SHALL NOT EXCEED MORE THAN 5-PSF FOR OF NE N3R NEMA 3R BOX W/ENVOY-S ® FIRE SETBACKS PHOTOVOLTAIC AND NO MORE THAN 6-PSF FOR RESIDENTIAL SOLAR HOT WATER SYSTEMS. CB COMBINER BOX GROUND ACCESS ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT CUSTOMER INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A INFORMATION a MODULE PITCH DIRECTION PLUMBING PERMIT AND INSPECTION. BRYAN PETTY INVERTER PLACEMENT: 520 TRACK AVENUE CUTCHOGUE, NY, 11935 631-734-5323 SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE OF EACH MODULE. JURISTICTION:SUFFOLK BILL OF MATERIALS UTILITY: PSEGLI BUILDING REVIEW NOTE: MODULES sz UTILITY ACCT#: UTILITY METER#: TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE ENCLOSED DOCUMENT FOR INVERTERS 52 MINIMUM ACCEPTABLE PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS SPECIFIED PV SYSTEM IN THE BUILDING AND/OR RESIDENTIAL CODE OF THE STATE OF NEW YORK. CLAMP ASSEMBLY 130 INFORMATION THISREVIEW DOES NOT GUARANTEE COMPLIANCE OF THAT CODE. THAT COUPLING ASSEMBLY 54 SYSTEM SIZE(DC): 14.56 KW RESPONSIBILITY IS GUARANTEED UNDER THE SEAL AND SIGNATURE OF THE NEW 52 MODULES: RECOM RCM-280-6MB YORK LICENSED DESIGN PROFESSIONAL OF RECORD. THAT SEAL AND SIGNATURE BONDING CLIP 16 HAS BEEN INTERPRETED AS AN ATTESTATION THAT, TO THE BEST OF THE LICENSEE'S SKIRTS 16 52 INVERTERS: ENPHASE IQ6-60-2-US BELIEF AND INFORMATION, THE WORK IN DOCUMENT IS: LOAD CENTER 1 1. ACCURATE 100A FUSIBLE AC DISCONNECT 1 2. CONFORMS WITH GOVERNING CODES APPLICABLE AT THE TIME OF THE PROJECT INFORMATION SUBMISSION. 70A FUSES 2 3. CONFORMS WITH REASONABLE STANDARDS OF PRACTICE AND WITH VIEW TO INITIAL DATE 10/30/2017 DESIGNER:MM THE SAFEGUARDING OF LIFE, HEALTH, PROPERTY AND PUBLIC WELFARE IS THE 1254 LINE TAPS 2 REV DATE: DESIGNER: RESPONSIBILITY OF THE LICENSEE. 20A BREAKERS 4 REV: DATE: DESIGNER. 15A BREAKER 1 COVER PAGE ENVOY-S 1 ' NEMA 311 PVC BOX 1 PV- 1 1 ALL WIND DESIGN CRITERIA ARE FOR GABLE AND HIP RESIDENTIAL ROOFS SEE ATTACHMENT SCHEDULE FOR MAXIMUM CANTILEVER CONSIDERED FROM AN ANGLE OF MIN. 9.5°(j)TO MAX.45°(ij) NOT TO EXCEED COUPLING ❑ 30' MEAN ROOF HEIGHT WITH A MIN J"LAG BOLT(ASTE A276)STAINLESS STEEL CLAMP& momentum INTO THE RAFTER OR BLOCKING BETWEEN RAFTERS W/MIN. EMBEDMENT OF 3" ATTACHMENT 2. THIS STRUCTURAL DESIGN REFLECTS STRUCTURAL CONNECTIONS TO THE IAFTE SOLAR RECOM RCM-280-6MB EXISTING STRUCTURE ONLY MODULE TO ECO-X LOADING AND CERTIFICATION SOLAR MODUL 280 WATT MODULE PER MECHANICAL LOAD TESTS IAW/ANSI UL2703 CONDUCTED ON BEHALF OF 64. T' X 39.06" X 1 3811 ( ) PRO 325 HIGH STREErUSTOM SOLAR CMETUC ENMNJ 08840ENTUM 0LAR ECOLIBRIUM SOLAR BY TUV RHEELAND REFERENCE FILE L2-ELS150128a REV 1 SEE DATASHEET) 3. ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511 AND IS THE (732)902-6224 RESPONSIBILITY OF THE CONTRACTOR TO FILL ALL HOLES WATER TIGHT GUTTE MOMENTUMSOLAR.COM 4 "ECO-X"ATTACHMENTS ARE MANUFACTURED BY ECOLIBRIUM SOLAR,ATHENS, STRUCTURAL CLIMATIC & GEOGRAPHIC DESIGN GEORGIA.AND SHALL BE INSTALLED IN STRICT COMPLIANCE WITH ENGINEERING RS PRINTED INSTRUCTIONS MINIMUM TO GUTTER DUNZI CRITERIA TABLE R301.2(1) ECOLIBRIUM SOLAR ECO-X MOUNTING DETAIL LICENSE M 03 534 RA TEED•AP MANUFACTURE - DANIELW. ECO-X TO RAFTER ATTACHMENT SPACING SCHEDULE ECOLIBRIUM SOLAR ECO X RAIL-LESS MOUNTING SYSTEM (908)872-3664 GROUND SNOW LOAD 25 LBS/SF INTEGRATED WITH FLASHING,COUPLINGS AND ADJUSTABLE 370 BURNT HILLNJ ROAD CLAMP ATTACHMENTS SKILLMAN,ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND SPEED (MPH) 135 MPH ULTIMATE AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE TOPOGRAPHIC EFFECTS B DESIGN ROOF ZONE 1 &2 ROOF ZONE 3 MAXIMUM SOLAR ARRAY ELEVATION 4.25" ANY PERSON,UNLESS ACTING UNDER THE DIRCOMPLIANCE.WARNING THAT IT IS A EN OF THE CTION OF A W FOR WIND MAX. SPAN/MAX. MAX. SPAN/MAX. LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY SPECIAL WIND REGION NO SPEED CANTILEVER CANTILEVER MAXIMUM CLAMP ATTACHMENT SPACING 48" WIND BORNE DEBRIS ZONE 2 (MPH) (INCHES) (INCHES) 115 48"O C /16"MAX. 32"0 C /12"MAX. ��RED ARC SEISMIC DESIGN CATEGORY C 125 48"0 C /16"MAX. 32"O C / 12"MAX. COUPLING CLAM ��� P����W �UN�i CLIMATE ZONE 5A 130 48"0 C./16"MAX. 32"O.0 / 12"MAX. Wint WIND EXPOSURE CATEGORY g 140 48"0 C /16"MAX. 24"O C /10"MAX. SOLID BLOCKING "mil ., 150 48"O C /16"MAX. 24"0 C /8"MAX. BETWEEN JOISTS o ,Q 160 32"O C /12"MAX. 16"0 C /8"MAX. w -- m TABLE REFLECTS ATTACHMENT SPACINGS THAT EXCEED MANUFACTURERS w (I)� �„w Q� SPECIFICATIONS FOR WIND LOADS AS PER ASCE 07-10 RISK CATEGORY II r' '9T 039534 y0 TOPOGRAPHIC EFFECTS B,C,&D AND ROOF WIND ZONES 1,24 3. ROOF ZONES 2&3 FASTENER REQUIREMENTS: OF NE`N ARE WITHIN 36"OF ANY OUTER EDGE, HIP, RIDGE, OR GUTTER LINE FOR STRUCTURES 30'-0" OR LESS MEAN ROOF HEIGHT TOTAL ARRAY AREA=910.76 SQ FT WIND LOAD-ASCE 10(SEE CALCULATIONS,STRUCTURAL CERTIFICATION)50 PSF MAX TOTAL UPLIFT 50 PSF X 910.76=45537.99 LBS CUSTOMER GUTTER GUTTER INFORMATION ® ® ® ® FASTENER: LAG SCREW SPEC 203.2,8/04:(FLAT WASHERS TO BE USED WITH LAG BOLTS) BRYAN PETTY LU LAG BOLT WITHDRAWAL VALUE 5/16"DIA.,266 LB/IN X 2-INCH THREAD DEPTH: 520 TRACK AVENUE q ® m p ® LU 532LB.CAP.EACH CUTCHOGUE, NY, 11935 ��Q ® MINIMUM NUMBER OF LAG BOLTS REQUIRED:45537.99 LBS/532 LBS/LAG BOLT=86 631-734-5323 MAXIMUM SPAN BETWEEN MOUNTING FEET BOLTS"X"USE 48"MAX ALLOWED AS ® 2 ® RIDGE RIDGE ® ® PER SCHEDULE ® ® ® ®® � ® JURISTICTION:SUFFOLK 'S%o STRUCTURAL STATEMENT: UTILITY: PSEGLI LU UTILITY ACCT#: < a © m THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE UTILITY METER#: NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE ® ® GUTTER ® GUTTER ® SYSTEM INCLUDING UPLIFT&SHEAR.EXISTING RAFTER PV SYSTEM SIZES & DIMENSIONS CONFIRM TO IRC-2015 TABLE INFORMATION R802.5(1)-RAFTER SPANS. SYSTEM SIZE(DC): 14.56 KW ROOF WIND ZONES AS PER IRC R301.2(7) 52 MODULES: RECOM RCM-280-6MB ROOF ZONES 2&3 ARE 36"FROM OUTTER ROOF EDGES, MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED NEW YORK STATE CODE REQUIREMENTS FOR THE DESIGN 52 INVERTERS: ENPHASE IQ6-60-2-US RIDGES, HIPS, RAKES,AND GUTTER EDGES FOR STRUCTURES CRITERIA OF THE TOWN. BELOW 30'-0"MEAN ROOF HT PROJECT INFORMATION INITIAL DATE: 10/30/2017 DESIGNER:MM REV: DATE: DESIGNER: REV* DATE: DESIGNER: COVER PAGE PV- 1 ( 2 SCALE: 3/32" = V-0" LOCATION 41.01229297, -72.47322897 ROOF MODULE COUNT TILT AZIMUTH SHADING R1 8 11° 213° 96% R2 16 20° 213° 91% momentum R3 5 19° 1 213° 1 87% SOLAR R4 23 21° 33° 95% PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR TRACK AVE 325 HIGH STREET,METUCHEN,NJ 08840 (732)902-6224 O MOMENTUMSOLAR.COM Q STRUCTURAL ENGINEERING DANIEL W.DUNZIK RA LEED-AP LICENSE#039534 (908)872-3664 370 BURNT HILL ROAD SKILLMAN,NJ 08558 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR O ANY PERSON,UNLESS ACTING UNDER THE DIRECTIONOF A LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY WAY FRONT OF RESIDENCE RED ARC �'� q I �'9TF039534-nt y0 OF NE CUSTOMER INFORMATION MSP BRYAN PETTY LC N3R DCO 520 TRACK AVENUE GROUND ACCESS CUTCHOGUE, NY, 11935 ELECTRICAL EQUIPMENT 0 0 R4 (7YP) 631-734-5323 0 ❑ 0 ❑ 0 0 ❑ JURISTICTION:SUFFOLK UTILITY: PSEGLI FIRE SETBACK 0 0 0 0 0 0 ❑ ACCESS ROOF UTILITY ACCT#: (18" VENTILATION, UTILITY METER#: t 36" ROOF ACCESS) 0 0 0 0 0 ❑ ❑ I PV SYSTEM RIDGE INFORMATION ® R1 ® p R20 0 r -f o R3 SYSTEM SIZE(DC): 14.56 KW +I 52 MODULES: RECOM RCM-280-6MB 0 ❑ 0 p p p 0 52 INVERTERS: ENPHASE IQ6-60-2-US 0 0 0 0 0 0 0 ❑ ❑ 0 0 RIDGE 0 0 0 0 0 0 0 PROJECT INFORMATION GUTTER GUTTER 0 0 INITIAL DATE 10/30/2017 DESIGNER:MM SOLAR INSTALLER NOTES: NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED REV* DATE: DESIGNER: METER RISER UPGRADE REQUIRED REV: DATE: DESIGNER: PANEL LAYOUT GUTTER PV-2 R1 - ARRAY 1 LAYOUT DETAIL R2 - ARRAY 2 LAYOUT DETAIL SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" (0 TILT: 11° 0'-6-10--92-1- '-22" TILT: 20° momentum AZIMUTH: 213° -4T AZIMUTH: 213° SOLAR SHADING: 96% SHADING: 91% 4'-7" PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR ® ® 325 HIGH STREET,METUCHEN,NJ 08840 (732)902-6224 MOMENTUMSOLAR.COM ❑ ❑ 0'-5„ 27'-0" 0'-5" STRUCTURAL 1'-6" ENGINEERING DUNZIK RA LEED-AP ❑ ❑ LICENSE*039534 B ® 370 BURNT HILL ROAD 13'_22" LETTE ❑ ❑ ❑ 0 SKILLMAN,NJ 08558 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE ° ❑ ❑ ❑ ❑ COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A 0 ❑ LICENSED ARCHITECT,TO ALTER AN REM IN ANY WAY 13'-22" ❑ 0 ❑ 0 0 ?,ED ARCy/� C7 "\-W 9'-32., 0 ❑ 0 ❑ ❑ 0'-82.' 441 y 039534 y SOLAR INSTALLER NOTES: SOLAR INSTALLER NOTES: TF OF NES NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED R3 - ARRAY 3 LAYOUT DETAIL R4 - ARRAY 4 LAYOUT DETAIL CUSTOMER SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" INFORMATION TILT: 19° TILT: 21° BRYAN PETTY AZIMUTH: 213° AZIMUTH: 33° 520 TRACK AVENUE CUTCHOGUE, NY, 11935 SHADING: 87% SHADING: 95% 631-734-5323 JURISTICTION:SUFFOLK 0'-82" �}' 13'-1" 20'-2" 2'-42" 37'-92" 2'-42„ t1 UTILITY: CCT# LI UTILITY ACCT#: 1 -6 UTILITY METER#: PV SYSTEM o a o 0 ❑ ❑ 0 0 0 ❑ INFORMATION SYSTEM SIZE(DC): 14.56 KW ;9 10'-10" ❑ 0 0 0 ❑ 0 ❑ 52 MODULES: RECOM RCM-280-6MB o a O 52 INVERTERS: ENPHASE IQ6-60-2-US 13'-22" ° ❑ ❑ ❑ ❑ ❑ ❑ ❑ 3,"O„ F-1 0 ❑ PROJECT INFORMATION INITIAL DATE: 10/30/2017 DESIGNER:MM 0'-821n REV: DATE: DESIGNER: REV: DATE: DESIGNER: LAYOUT DETAIL SOLAR INSTALLER NOTES: SOLAR INSTALLER NOTES: NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED PV-3 52 RECOM RCM-280-6MB 280W MODULES PAIRED WITH ®' 52 ENPHASE IQ6-60-2-US MICRO-INVERTERS momentum SOLAR BRANCH CIRCUITEXISITING MURRAY 100A 13 MICRO-INVERTERS NEMA 3R BOX PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR BRANCH CIRCUIT B MAIN SERVICE PANEL 240 V 325 HIGH STREET,METUCHEN,NJ 08840 13 MICRO-INVERTERS BRANCH CIRCUIT E.w a (732)902-6224 BRANCH CIRCUIT C MAIN BREAKER: 100A MOMENTUMSOLAR.COM 13 MICRO-INVERTERS 125 AMP STRUCTURAL BRANCH CIRCUIT D LOAD CENTER INE SIDE 13 MICRO-INVERTERS HOT TAP ENGINEERING DANIEL W.DUNZIK RA LEED-AP LICENSE*039534 (908)872-3664 100A 370 BURNT HILL ROAD ■ ■ ■ SQUARE-D 100A SKILLMAN,N7 08558 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND FUSIBLE AC UTILITY AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& S 3A CODE DISCONNECT METER ATTACHMENTS WARM G TET HAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A rn AL LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY 7oA ELECTRICIAN HANDLER POWER CORP DARREN HANDLER ROOF 15A BREAKER (ENVOY) POWER 24 CORDELL PUCE JUNCTION 20A BREAKER (A) 70A FUSES EAST NORTMPORT,N L GROUND TERMINATION CAP 1 BOX 2A-D 20A BREAKER (B) 3 4 GRID �g� \��wpVN y�T� 20A BREAKER (C) INSTALLED ON END OF CABLE 20A BREAKER (D) ELECTRICAL NOTES: 4 BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST BRANCH CIRCUIT IN SYSTEM. OTHER BRANCH CIRCUITS SOLAR INSTALLER NOTES: '9T 039534 yO 1 ALL CALCULATIONS FOR VOC,AMAX, IMP AND IGC HAVE BEEN CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON WILL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN 100A METER RISER UPGRADE REQUIRED NES ASHRAE 2%HIGH AND EXTREME MINIMUM TEMPERATURE COEFICIENTS. 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2014 ARTICLE 310 CUSTOMER 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 INFORMATION paragraph C). THE GROUND IS CARRIED AWAY FROM THE GROUNDING LUG 6.ALL EQUIPMENT INSTALLED IS RATED AT 90°C BRYAN PETTY USING #6 BARE COPPER WIRE. 7 INVERTER NOC(NOMINAL OPEN CURRENT)OBTAINED FROM 520 TRACK AVENUE 3. THIS SYSTEM COMPLIES WITH NEC 2014 EQUIPMENT DATASHEET CUTCHOGUE, NY, 11935 631-734-5323 JURISTICTION:SUFFOLK UTILITY: PSEGLI UTILITY ACCT#: UTILITY METER#: PV SYSTEM INFORMATION SYSTEM SIZE(DC): 14.56 KW 52 MODULES: RECOM RCM-280-6MB Wire Ta Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire 52 INVERTERS: ENPHASE IQ6-60-2-US Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC(A) Correction Current(A) Size Type 1 Open Air 2 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 13 0.96 1.25 15.60 12 AWG Trunk Cable 2A 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 13 0.96 1.25 15.60 08 AWG THWN-2 PROJECT INFORMATION 2B 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 13 0.96 1.25 15.60 08 AWG THWN-2 INITIAL DATE: 10/30/2017 DESIGNER:MM REV: DATE DESIGNER: 2C 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 13 0.96 1.25 15.60 08 AWG THWN-2 REV: DATE: DESIGNER: 21) 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 13 0.96 1.25 15.60 08 AWG THWN-2 ELECTRICAL 3 V, PVC 3 06 AWG THWN-2 90°C 75 0.96 1 72.00 52 0.96 1.25 62.40 08 AWG THWN-2 4 1" PVC 3 06 AWG7 THWN-2 I 90°C 1 75 0.96 1 72.00 52 0.96 1.25 62.40 08 AWG THWN-2 PV-4 TAG LABEL QUANTITY LOCATION NOTE EXAMPLES 1 AT EVERY SEPARATION BY m o m e n t u m QA 12 DC CONDUITS ENCLOSURES/WALLS/ SOLAR PARTITIONS/CEILINGS/FLOORS OR NO MORE THAN 10' _ • • • © PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 9IDA �S➢i °Ie 325 HIGH STREET,METUCHEN,NJ 08840 (732)902-6224 MOMENTUMSOLAR.COM STRUCTURAL ENGINEERING © 1 COMBINER BOX 1 AT ANY JUNCTION BOX OR DC J� �i LDANIEL ICENSE W. DUN0 g ZIK RA LEED-AP 34 COMBINER IF USED O �. -3664 (908)872 HILL ROAD • SKILLMAN,N7 08558 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS 8 • ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR • ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY -�\�RED ARC,y © 1 JUNCTION BOX 1 AT ANY JUNCTION BOX OR DC �<C/� OPS '\\N_ COMBINER IF USED mos i N a DISCONNECT • '9,, 039534 yO�- f F OF NE`N CUSTOMER 1 OF EACH AT FUSED AC ©O DISCONNECT INFORMATION 1 AC DISCONNECT COMPLETE VOLTAGE AND BRYAN PETTY CURRENT VALUES ON DISCONNECT LABEL 520 TRACK AVENUE CUTCHOGUE, NY, 11935 631-734-5323 JURISTICTION:SUFFOLK UTILITY: PSEGLI _ UTILITY ACCT#: O UTILITY METER#: k Q 1 MAIN DISCONNECT 1 OF EACH AT BUILDING MAIN _. —' - PV SYSTEM PANEL DISCONNECT PANEL '_ INFORMATION SYSTEM SIZE(DC): 14.56 KW - _ 52 MODULES: RECOM RCM-280-6MB 52 INVERTERS: ENPHASE IQ6-60-2-US _ � o anow�•u�as PROJECT INFORMATION O _ INITIAL DATE 10/30/2017 DESIGNER:MM QF 1 UTILITY METER 1 AT UTILITY METER REV DATE: DESIGNER: REV: DATE: DESIGNER: EQUIPMENT LABELS PV-5 The new EcoX is an innovative, - ff rail-less racking system, proven ; to organize the installation _- process. The flexible design offers a clean aesthetic, simplified logistics, and delivers a higher quality installation '' at a lower cost per watt. Aesthetic Design Cable Management tih � , ' Kie t, A wide range of adjustment makes it easy to install a Whether installing with Microinverters, Power E )1I straight, level system. Components are designed to Optimizers, or String Inverters, EcoX provides wire blend into the array, and the aesthetic skirt,creates management provisions to both prep the modules, and �* a finished look. Alternatively, a skirt free option is to route homerun or trunk cables throughout the array available to provide a more traditional look. -Y_ f lINM G^-Z.,..•.,'. _> -�'Jf ff-.�I t !I N` •I _tt.11 3� �S`-l' 1i-.S'-1t.�_ i �. ... y WEI layout ;�� � .0 MPwbMl.w.aMM,eM 5i � - • '� — - - •OPC.edaowl.nM 4pYlp mnpnll t - _ .rte t-,, -_may- . -- -_ ..-.. __.- . - -. _.-.._ ._ ._- _- _ - .�: �'� � � ®®®�®®® : • , I f Flexible System Design Single Point Grounding The EcoX Estimator is a powerful racking system EcoX and approved modules create a continuously design tool.The user inputs all site conditions and bonded system. The installer can connect a Finished can layout multiple roof surfaces. The EcoX Estimator array to ground with a single bonding lug. outputs a site speciFic design package with engineering specs and bill ofmaterials. Technical Specifications Racking components Aluminum, stainless hardware, dark Fast. Simple. Supported. Materials bronze anodized upper surface, mill finish lower surFaces Flashings.Aluminum, black powder coated finish, Modules drop in From above Universal components mount to The Ecolibrium Field support team and there is never a need to standard Framed modules. With offers on-site installation training Grounding/Bonding Validation UL2703 - see installation manual For specihc module approvals reach over or walk on modules a single socket size and a wide and ongoing technical support. Fire Resistance Validation UL2703 - Class A,Type 1 and Type 2 modules Pre-assembled components range oFadjustment, it is quick And From project planning to and quick connections make and easy to install any array logistics to installation, we are Mechanical Load Validation UL2703 - see installation manual For specific module approvals EcoX easy to install. with a clean, Finished look. dedicated to customer service Flashing Validation I ,- ' ICC-ES AC286/UL441 Rain Test for Roof Flashing ' ® Adjustability 1"vertical range, 3.5" North/South range, �.� connect anywhere in East/West direction Warranty 15 years salesRecolibriumsolarcom US.740-249-1877 www.ecolibriumsolar.com EcolibriumSolar salesPecolibriumsolarcom US 740-249-1877 www.ecolibriumsolar.com WA, EolibriumSolar y Data Sheet Enphase Microinverters Enphase IQ 6 and IQ 6+ Microinverters INPUT DATA(DC) IQ6-60-2-US AND IQ6-60-5-US IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US Commonly used module pairings' 195 W-330 W+ 235W-400W+ } Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V. y-�- 62 V Enphase The high-powered smart grid-ready power _ - -- Peak power tracking voltage 27 V-37 V 27V-45V p Enphase IQ 6 Micro'" and Enphase IQ 6+ Micro'" Operating range 16V-48V _ -- 16 V-62 V Q 6 a n d IQ 6+ dramatically simplify the installation process while Min/Max start voltage 22 V/48 V 22 V/62 V Max DC short circuit current(module Isc) 15 A 15 A ffi - achieving the highest efficiency for module-level —_ — _ Microinverters power electronics Overvoltage class DC port r DC port backfeed under single fault 0 A T - ^- _ 00 A- Part of the Enphase IQ System,the IQ 6 and IQ PV array configuration - 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit 6+ Micro integrate seamlessly with the Enphase OUTPUT DATA(AC) IQ6-60-2-US AND IQ6-60-5-US IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US IQ Envoy"", Enphase Q Aggregator"", Enphase IQ -Peak output power 240 VA 290 VA _ R Battery"",and the Enphase Enlighten- monitoring Maximum continuous output power T`y 230 VA 280 VA Nominal voltage/range2 _ _ z40 V_/211-264 V �y .208 V(10)/183-229 V 240 V/211-264 V 208V(14))/183-229V. and analysis software — - - -- .- - - - ---- --- - _-. _._ ._. -----__--- Nominal output current 0.96 A 1 11 A 117 AT 1.35 A Nominal frequency 60 Hz 60 Hz The IQ 6 and IQ 6+ Micro extend the reliability ._--.--_------.._._._—_._____.__-._--._------•_------_---_-------------------_-_-_ _.. standards set forth by previous generations and Extended frequency range - _ v 47 68 Hz� 47-68 Hz� Power factor at rated power- _ 1 0 ~ _ 1.0 undergo over a million hours of ower-on testing �..-- _. 9 P g Maximum units per 20 A branch circuit � 16(240 VAC) 13(240 VAC) Enabling Enphase to provide an industry-leading 14(single-phase 208 VAC) 11 (single-phase 208 VAC) warranty of up to 25 years. Overvoltage class AC port III III i AC port backfeed under single fault 0 A 0 A j' Power factor(adjustable)�Y-- 0.7 leading-0.7 Fagging '-- EFFICIENCY @240 V @208 V(14)) t✓1a 240 V @208 V(10) Easy to Install I CEO weighted efficiency 970% 96.5% 97.0% • Lightweight and simple MECHANICAL DATA -400C O Ambient temperature range r %to to+65cC Faster installation with improved two-wire Relative humidity range _ 4°�to 100°�(condensing) cabling _,_v b Connector type MC4 or Amphenol H4 UTX Built-in rapid shutdown compliant(NEC 2014) --- ------ ----- - - -- - -—---- ----.---- _ --- _ - .__.___. ._ Dimensions(WxHxD) 219 mm x 191 mm x 379 mm bracket) (without Weight -_- -----L5kg(3.3Ibs) - - Cooling Natural convection-No fans Productive and Reliable -=- - = _ -- -•�;��.x,t Approved for wet locations 0 timized for high powered 60-cell and 72- - ,T._.�. P 9 P Pollution degree PD3 cell*modules Environmental category/UV exposure rating Outdoor NEMA 250,type 6(IP67) _U m More than a million hours of testing FEATURES Class 11 double-insulated enclosure Communication Power line i Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Smart Grid Ready Compliance _~- - - '_- UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO 1071-01 i Complies with fixed power factor,voltage and This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and s frequency ride-through requirements NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC ' Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions. grid requirements _ 1 No enforced DC/AC ratio.See the compatibility calculator at ennhase.com/en-us/support/module-compatibility Configurable for varying grid profiles 2.Nominal voltage range can be extended beyond nominal if required by the utility U� *The IQ 6+Micro is required to support 72-cell modules To learn more about Enphase offerings,visit enphase.com E N P H A S E. ©2017 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. v E N P H A S E. To learn more about Enphase offerings,visit enphase.com \./ 2017-05-01 RECMM RECOm MONO MONO 250 260 270 280 RCM-xxx-6MB (xxx=250-280) 9 Rated Power 250W 260W 270W 28OW 7 —aoerem Power Tolerance 0%/+5W O%/+5W 0%/+5W 0%/+5W — � 6 - Max.Power Voltage31.30V 31 70V 32.12V 32.50V 5 5 (Vmp): 4 - _ Max.Power Current(Imp): 8.09A 8.32A 8.45A 8.67A 3 2 Open Circuit Voltage(Voc): 37 92V 38.52V 38.76V 39.20V 1 ` o Short Circuit Current(Isc): 8.51A 8.66A 8.78A 8.99A o s 10 15 20 25 30 35 40 _ Map lVl Pmax(NOCT): 200.8W 206.8W 216.6W 223.9W The module relative power loss of low light irradiance of200W/m'isless than 3%. h' Module Efficiency 15.4% 16,0% 16.6% 177% ' 2 Max.Series Fuse: 15A 15A 15A 15A Pmax Temperature Coefficient -0.39%/0C Vac Temperature Coefficient -0.32%/°C Max.System Voltage: l 000V DC(IEC)/I OOOV DC(UL) Isc Temperature Coefficient +0.05%/'C f r, Tested at Standard Test Conditions.Measurement tolerances:t 3% Operating Temperature -40-+850C Nominal Operating Cell Temperature(NOCT) 45±2 0C E A — -- .t,�- .` e(•,-."��.�x . lM119�Gl1LY•1SL•L•tSJ Dimensions 1640mm x 992mm x 35mm Container 20'GP 40'HC Frame Anodized aluminum Pieces per Pallet 29 or 30 29 or 30 fl Weight 19 kgs Pallets per Container 12 28 Front Glass 3.2 mm AR low iron tempered'glass Pieces per Container, 348 or 360 812 or 840 Output Cables: TUV(2Pfgl 169.2007).UL 4703 UL44 4.0 mm2 , ^ (0.006 in').symmetrical lengths(-)1000mm and(+)1000 mm.MC4 type connectors Standard tests UL1703.IEC 61215.IEC 61730 Quality tests ISO 9001 2008.ISO 14001 2004.1S017025:2005 Class C Fire Rating.conformity to CE.PV CYCLE. Certifications Salt Mist and Ammonia Corrosion E Extreme wind and Module certified to withstand extreme wind 1640mm snow loads testing (2400 Pascal)and snow loads(5400 Pascal) m 1 a Positive tolerance Guaranteed positive tolerance of up to 5W Junction Box IP67 Rated,3 diodes 1000mm Warranties •10-year limited product warranty —'— • E 25-year transferable linear power output warranty �I Black Panther E _ LINEAR PERFORMANCE WARRANTY N P P 11 m ( � AdtlGonat val�,6 a1 _ an RECOM's#new warrant' ' nn u n " Years 0 1 b 10 IS 20 25 Manufactured Anti-PID �lly� Proven by Independent + Guaranteed Specifications are subject to change without further notification CIL,,,.,}ar,c.d 13RECOM P b <5W) Release 2014-02 Q.1 in EU S Technology I Ibo Engineering Tests �_ 1 Positive Power „„„«,,„ a. ...or mr m« n«. m•�.n«.ar•b NaRNi al anon t Wyau:en•ra a muJcrmakn of+ 6 Deater: CE riot (1 recon-solar.com