Loading...
HomeMy WebLinkAbout42047-Z Town of Southold 2/22/2018 P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39528 Date: 2/22/2018 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 305 Birch Ln, Cutchogue SCTM#: 473889 Sec/Block/Lot: 83.-1-29 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/6/2017 pursuant to which Building Permit No. 42047 dated 10/12/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels on existing one family dwelling as applied for. The certificate is issued to Borsen, Andrew&Morgan of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 42047 1/12/2018 PLUMBERS CERTIFICATION DATED ON uthorized Signature TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 42047 Date: 10/12/2017 Permission is hereby granted to: Borsen, Andrew & Morgan 3 Peter Cooper Rd #11A New York, NY 10010 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 305 Birch Ln, Cutchogue SCTM # 473889 Sec/Block/Lot# 83.-1-29 Pursuant to application dated 10/6/2017 and approved by the Building Inspector. To expire on 4/13/2019. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00, Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial $15.00 / D-a . r/a`b '� ? New Construction: Old or Pre-existing Building: L11 (check one) Location ofProperty-:_� S ►4tvr � rt4Gi4l House No. Street Hamlet Owner or Owners of PropertyJ Lo fSeyk Suffolk County Tax Map No 1000, Section .93 Block l Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant- Health Dept. Approval: Underwriters Approval: Planning Board Approval: / Request for- Temporary Certificate Final Certificate: (check one) Fee Submitted: $ Applicant Signature �o��oF so�jyol Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G Q Southold,NY 11971-09590 • �o roger.richert(a�town.southoId.ny.us �y�ouNm, ' BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To. Borsen Address: 305 Birch Lane city Cutchogue st: New York zip: 11935 Building Permit#- 42047 Section: 83 Block. 1 Lot: 29 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Advanced Electric Design License No. 5173-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures tl TVSS Other Equipment: 10.56 KW Roof Mounted Photovoltaic System to Include 32- LG 330 w Panels, with Enphase Micro Inverters, AC Disconnect. Notes: Inspector Signature: Date: January 12, 2018 0-Cert Electrical Compliance Form.xls 0FS0cp UT�o`o Q TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) k- ELECTRICAL (FINAL) REMARKS: DATE l �T/ �� INSPECTOR i I i ENGINEERED SOLU110NS O:ESIG:B: E161AEll N IONSUI Ip6 .Mr._J;osli.Heinz FebrVary,2J-,,2'014,8' Sunrise:Solar Solutions;,LLC' S:1:0'N6rth.SWe.Road Briarcliff MarioT lYY;'I�g51j0' RE; B:orset Residence=--305Birch:Lane;Cutchoque;NY :11935 AIG Projecf#.1732R' We have,inspecfed the installat on:of.the:solar.array and the strudture(S,).-at the above rdference' address, � Tlre.array;corisists ;I<G modules o-A,' :residence;mounted,on:a:.Uiurac-racking system with'a iriaximtpn of tachmeni spc acing of;4's=0"on enter,: We'hereby:cert>ify-ahai the:array has;:been:in sffli edlh accofd'arice with 66,flus,:as', ,,prepared by'S'unri§.e S.olar,;.dated<9%5%17. In.addition,tlie.'.install'ation.o_f;thesolar;array confofiri"s`to;the,:requiteirients:of the,"New York:State:Uiuform�Fire Preyention_and BwldW Please:feel`free ta,contact::us should:yoiu.,l aue.any:coirirrients.or questions. Respectfiil..Y.YQUrs, .OF sE VlattFieiv B ce, : '� ' IvIatthewj Boyce;PE _ n, t All SIA.. . M s . o DD FEB 222018 i BUILDING DEPT. TOWN OF$OUTSOLD E n'g i,we.e:r a 4 S,o t u t i o n.s, L L C 3316,8 Carriage C"ro-ssing Saint .C.11arle.s., MO '63.301 i FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) H ------------------------------------ O FOUNDATION (2ND) z 03 o � ROUGH FRAMING& PLUMBING , y S r r� INSULATION PER N.Y. STATE ENERGY CODE O FINAL ADDITIONAL COMMENTS O Kid r-lcl3qn v) Z m r w y O P � d TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O. Application Flood Permit Examined �' ,20� Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved D �/ ,2011— Mail to: Disapproved a/c Expiration ,20 r DIE lding pector D APPLICATION FOR BUILDING PERMIT OCT - 6 2011 Date /0 - 6 , 20 / INSTRUCTIONS BUU,DING DEPT. ,I. " T pyfttVST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets 091 ppgans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances, building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. t��l IA ►JG� eL-eG�-fir c, �-e s�y�, (Signature of applicant or name,if a corporation)GoA3,�KL S3 � hPIOAn S ReA (_ ed M6G 1 JJU (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, ectricia lumber or builder Name of owner of premises�p'��`e!/l (As on the tax roll or latest deed). If app ican js,a cc1'rporation� i nature of duly auth rized officer, U eiP . �rt'] (Name.ari >titl;eofcovporate officer) lllde'r-s' Licensd'N'0`�"21`j Plumbers License No. Electricians License No. Sl 73 M P. Other Trade's License No. 1. Location of land on which pro osed work will be done: a s 'Qt t A n �L1j104 u House Number Street Hamlet County Tax Map No. 1000 Section Block Lot g Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b�t Intended use and occupancy 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work o /4 f-- (Description) `(Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars" 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear f Depth £- ,L, Height Number of Stories ` j r'/1 ! 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated _ 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premises Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 91F Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE QUIRED. b. Is this property within 300 feet of a tidal-wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. Y8. Are there any covenant's and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, CONNIE D.BUNCH :Nom Public,we of New York j No.01 BU81850bfl (S)He is the .--in--dWk G0untY a� (Contractor,Agent, Corporate Officer, etc.) Com nisalon Expires Apr11 14.Z_ of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application, that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn Ao before me this 1, — day of 20_L-_- I�L ` � \ ~1 Notary Public 1 ti Signature of Applicant r~� Scott A. Russell ,��°SuFFQ,,r ST(0 R IAWATIER, SUPERVISOR o M[A\N A\ GI]ENHENT SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 y�0 Town of Southold d �� CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOLES THIS PROJECT INVOLVIE ANY OF THE FOLLOWING: Yes No (CHECK ALL THAT APPLY) ❑['fA. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ 16 B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑IJ C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. E][n D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑El E. Site preparation within the one-hundred-year f loodplain as depicted on FIRM Map of any watercourse. ❑0 F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT. (Property Owner,Design Professional,Agent,Contractor,Other) S.C.T.M # ]000 Date: f J." l NAME. CJ✓L✓L �J /I1G P�a Section L g3 g-�6 e-(7 F011BUILDING DEP:-:RTINILN"I- I:_'E. J_,I Contact Information: (Y?' 7.iro~r,.w,nmd � Reviewed By- - — — — — — — — — — — — — — — — — — Date: Property Address / Location of Construction Work. — — — — — — — — — — — — — — — — — TP.so DApproved for processing Building Permit J C, Stormwater Management Control Plan Not Required G w�( VL�LYu�i �� I `�'� ❑ Stormwater Management Control Plan is Required. (Forward to Engineering Department for Review.) FORM " SMCP -TOS MAY 2014 i Q?$Q(/ryOl . O Town Hall Annex Telephone(631)765-1802 54375 Main Road N m�ax(631)765-g5Q2 P.O.Box 1179 G� @ ro9er.richert(N1own.southolC]Inv.us Southold,NY 11971-0959 ? I BUILDING DEPARTMENT TOWN OF SOUTHOLD i. APPLICATION FOR ELECTRICAL INSPECTION I. REQUESTED BY: t Date: /0-G Company Name: �✓'iq,-,eec� eGc����c ,� CIO OY16"H"� rw C_ . Name: - License No.: S!73 ►�CJ�. -1 is Address: Phone No.: G a t- 8 3 9 6 6'Y� 1 JOBSITE INFORMATION: (*Indicates required information) *Name: a t>r S.e V� 1 *Address: �Zp !3 (Y— (,� L i G u.` 4-11 ora r— MY *Cross Street: *Phone No.: Permit No.: Ltd!D Tax Map District: 1000 Section: Block: Lot: *BRIEF DESCRIPTION OF WORK(Please Print Clearly) vv (Please Circle All That Apply) *Is job ready for inspection: YES/ NO Rough In Final *Do-you need a Temp Certificate: YES/ NO Temp Information(If needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION D .82=Request for lnspecGon Form I ho��pF SO!/r�ol Town Hall Annex 4 Telephone(631)765-1802 54375 Main Road N � Fax(631)765-9502 P.O.Box 1179 G • Q Southold,NY 11971-0959 4UM`I,Nc� January 18, 2018 BUILDING DEPARTMENT TOWN OF SOUTHOLD Advanced Electric 334 Hawkins Rd Centereach NY 11770 Re: Borsen, 305 Birch Lane, Cutchogue TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: NOTE: Post installation certification letter required to close out building permit Electrical Underwriters Certificate A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 411/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 42047 — Solar Panels Bunch, Connie From: Joshua Heinz <Josh@SunriseSolarllc.com> Sent: Wednesday, February 21, 2018 1:47 PM To: Bunch, Connie Subject: 305 Birch Lane, Cutchoque, NY 11935 Attachments: Borsen Installation Letter.pdf, PastedGraphic-l.tiff Hello Connie, I have attached a copy of the engineers letter of completion for the above address. Please let mw know if we can receive a copy of the Electrical Cert or CO. Thank you for your help, Joshua Heinz Sunrise Solar Solutions LLC 510 North State Rd Briarcliff Manor, NY 10510 914-762-7622 iosh(cDsunrisesolarllc.com D [997flvla D FEB 222018 BUMDING DEPT- TOWN OF SOUTDOLD i cc APPROVED AS NOTED DATE: B.P.# FEF: Z�_ BY ELECTRICAL ` AT 1NSpECTION REQUIRED NOTIFY 765-1802 c AM TO 4;::M FOR THE FCLLOW!' JG INSPECTIONS: 1. F IJ �-DATION - TV40 REQUIRED FOR TOURED CINGRETE 2. ROUGH F} ,' PLUMBING 3. IN IULAT 4. FINAL - ' -i MUST RETAIN STORM WATER RUNOFF BE COM. PURSUANT TO CHAPTER 236 ALL CONST SHALL MEET THE OF THE TOWN CODE. REDUIREMEt, OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF `30tf 17TOW"BA-1 sol-un-een MglAal of All a ►u02 2= OCCUPANCY OR USE IS UNLAWFUL W;ITHO.UT CERTIFICATE 0F OCCUPANCY ENGINEERED SOLUTIONS, DESIGN - ENGINEERING - CONSULTING Mr. Sam Mason September 6, 2017 Sunrise Solar Solutions, LLC 510 North State Road Briarcliff Manor,NY 10510 RE: Borsen Residence—305 Birch Lane, Cutchoque,NY 11935 AIG Project# 17.329 Mr. Mason: We have reviewed the proposed solar array and the structure(s) at the above referenced address. The array consists of(32) LG modules on the residence, mounted on a Unirac racking system with a maximum attachment spacing,of 4'-0"on center. We hereby certify that the existing structure, with the addition of the proposed solar energy devices is capable of supporting the design loads required by ASCE 7-10, IRC 2015, and the 2016 NYS Uniform Code Supplement. We have attached the calculation for the critical roof members for the structure—a 2" x 6"rafter and a 2" x 10"rafter, checked for bending stress and deflection in accordance with ASCE 7-10. Please feel free to contact us should you have any comments or questions. Respectfully yours, JKatthewI. Boyce, TE OF NEW9�/,-, Matthew J. Boyce, PE �Q'� SOSEPy��•Q� f aRa m I C7 IL !X �9820a Engineered Solutions, LLC 3368 Carriage Crossing Saint Charles, MO 63301 f Borsen Residence Title: Job# Critical Roof Member Dsgnr: Date: 9:14AM, 31 MAY 17 2x6 Rafter Description Dead Load 12 psf(with solar) Scope: Ground Snow Load 30 psf t Rev 580006 -� User.KW-060247a.Ver 5.8.0,I-Dec-2003Timber Beam & Joist Page 1 (c)1983-2003 ENERCALC Engineering So(p.rara Description Timber Member Information :ode Ref.1997/2001 NDS,2000/2003 IBC,2003 NFPA 5000.Base allowables are user defined Timber Section Beam Width In 2.000 Beam Depth in 6.000 Le:Unbraced Length 2.00 Timber Grade Nem Fr(North), No.1/No.2 Fb-Basic Allow psi 1,000.0 Fv-Basic Allow psi 145.0 Elastic Modulus ksi 1,600.0 Load Duration Factor 1.000 Member Type ManuflPine Repetitive Status Repetitive Center Span Data Span 12.00 Dead Load #/ 16.00 Live Load #/ 28.00 Results Ratio= 0.6920 Mmax @ Center in-k 9.50 @ X= 6.00 lb•Actual psi 792.0 Fb:Allowable psi 1,144.5 Bending OK tv:Actual psi 30.4 Fv:Allowable psi 145.0 Shear OK Reactions @ 7RightEnd L Ibs 96.00 L lbs 168.00 +LL lbs 264.00 @ L lbs 96.00 LL lbs 168.00 Max DL+LL lbs 264.00 Deflections Ratio OK Center DL Def! in -0.130 L/Defl Ratio 1,111,1 Center LL Def! in -0.227 L/Defl Ratio 634.9 Center Total Dell In -0.356 Location ft 6.000 UDefl Ratio 404 1 +S 6orsen Residence Title: Job# Critical Roof Member Dsgnr: Date: 9:15AM, 31 MAY 17 2x6 Rafter Description Dead Load 14 psf(with solar) Scope: Ground Snow Load 30 psf Rev: sa000s UserlCbV-0603478.Ver 5.8.0,1-Oec-2003 nn- Timber Beam & Joist Page 1 �(c)1983-2003 EllERCALC Engineering SaR: Description Timber Member Information :ode Ref: 1997/2001 NDS,2000/2003 IBC,2003 NFPA 5000.Base allowables are user defined Array 2 Timber Section Beam Width in 2.000 Beam Depth in f 10.000 Le:Unbraced Length 2.00 Timber Grade Hern Fv(Nath), No.VNo.2 Fb-Basic Allow psi 11000.0 Fv-Basic Allow psi 145.0 Elastic Modulus ksi 1,600.0 Load Duration Factor 1.000 Member Type Manuf/Pine Repetitive Status Repetitive Center Span Data Span 14.00 Dead Load #/ 18.00 Live Load #/ 28.00 Results Ratio= 0.3558 Mmax @ Center In-k 13.52 @ X= 7.00 fb:Actual psi 405.7 Fb:Allowable psi 1,140.4 Bending OK fv:Actual psi 21.4 Fv:Allowable psi 145.0 Shear OK Reactions @ Left End DL lbs 126.00 LL lbs 196.00 Max.DL+LL lbs 322.00 @ Right End DL lbs 126.00 LL lbs 196.00 Max DL+LL lbs 322.00 Deflections Ratio OK Center DL DO in -0.058 UDefl Ratio 2,879,5 Center LL Den in -0.091 UDefl Ratio 1,851.1 Center Total DO in -0.149 Location ft 7.000 UDefl Ratio 1,126,8 'Sorsen Residence Title: Job# Critical Roof Member Dsgnr. Date: 9:15AM, 31 MAY 17 2x6 Rafter Description Dead Load 14 psf(with solar) Scope: Ground Snow Load 30 psf Rear. 580006 UserK-2003E 78,ERCA CEng eerina o Timber Beam & Joist Page 1 (c)1983-2003 ENERCAiC Engneenng Soft,.•iare a rs Description Timber Member Information :ode Ref: 1997/2001 NDS,2000/2003 IBC,2003 NFPA 5000.Base allowabies are user defined May 3 Timber Section Beam Width i 2.000 Beam Depth in 6.000 Le:Unbraced Length 2.00 Tlmber Grade Nem Fir(nort)), No.1/No.2 Fb-Basic Allow psi 1,000.0 Fv-Basic Allow psi 145.0 Elastic Modulus ksi 1,600.0 Load Duration Factor 1.000 Member Type Manuf/Pine Repetitive Status Repetitive Center Span Data Span 13.00 Dead Load #/ 18.00 Live Load #/ 28.00 Results Ratio= 0.8490 Mmax @ Center in 11.66 @ X= ft 6.50 fb:Actual psi 971.7 Fb:Allowable psi 1,144.5 Bending OK fv:Actual psi 34.7 Fv:Allowable psi 145.0 Shear OK Reactions @ Left End DL lbs 117.00 LL lbs 182.00 Max.DL+LL lbs 299.00 @ Right End DL lbs 117.00 LL lbs 182.00 Max.DL+LL lbs 299.00 Deflections Ratio OK Center DL Deft in -0.201 UDefl Ratio 776,8 Center LL Dell in -0.312 UDefl Ratio 499.4 Center Total DO in -0.513 Location ft 6.500 UDefl Ratio 304.0 UTILITY METER N Ili MAIN DISTRIBUTION PANEL &SOLAR AC W EJAL . �� . DISCONNECT LOCATED IN THE BASEMENT td SII - C S I 405 ENRCH LN HI H t 1 I I " i ARRAY 3 ARRAY 1 r, Wind and Snow Load Wind Speed: 130 m.p.h. _ Snow Load: 30 p.s.f. a -- General Notes 1. Modules to be LG330 Watt and to installed per LG Electronics Installation Manual. 2. Inverters to be Ephase S280. 3. Racking to be Unirac and to be installed as per Unirac To all plans,specifications,plats and reports to which the seal of a professional engineer or land surveyor has been applied,there shall also be applied a stamp with appropriate wording warning Manufacturer's Specifications. that it is a violation of this law for any person,unless he is acting under the direction of a licensed professional engineer or land surveyor,to alter an item in any way.If an Item bearing the seal of an engineer or land surveyor is altered,the altering engineer or land surveyor shall affix to the Item his seal and notation"altered by"followed by his signature and the date of such alteration, and a specific descrlptllon of the alteration. Article 145,Professional Engineering and Land Surveying 7209(2) 510 N. State Rd. Site Plan DATE VER. DRAWNBY CHECKEDBY SYSTEM DESCRIPTION: NEW j, ? Briarcliff Manor, NY 04/19/2017 V1 BP DH -32 Photovoltaic Panels �OO 914.762.7622 05/20/2017 R1 CCW DH -LG 330 Watt UL A5 �OSEP�y$ �6 kW _ sunrisesolarllc.com Borsen Residence 09/5/2017 R2 CCW DH System size _864A 's k CC SYSTEM Cq 305 Birch Lane Array Array ♦c a •, R' Sunrise Solar Cutchoclue NY 11935 -Alt:20' :187° -Azimuth:187° r f -Tilt: -Tilt:7° Sect. 83 Block 1 Lot 29 Array 1 a2o$41 SOLUTIONS -Azimuth:100° os ' SITE PLAN .. JOB#17-24 -Tilt:8° NORTH N FRONT OF HOUSE W®E 43'-3" 5 [519"] 4'-3" 16'-9" 5._5.. 10'-02„ 6'_92„ 1._6.. 1'-6" [18"] [18"] [51"] [201"] [65"] [1201/2"] [811/2"] EAST SIDE OF _ HOUSE 7' 01.. L 5 _:. 7._02.. 1' 3" [84 1/2"] 1 „] 84 1/2"] [15"] \. WEST 13'-9" 1 _.,.. ,. . SIDE OF [165"] HOUSE 12"-7 12'-7" [151"1 [151"] \ . . . . . . . . . . . . .. . . . . _ . . . . _ ... _ SOUTH -c - _ BACK OF [304 : HOUSE 1'-2" [14"] N12'-94" Setback Requirements (153 1/4") Fire Clearance Path W Solar Arrays must maintain a 18" setback from all ridges, hips and E valleys or surface that abuts another adjacent roof. Solar Arrays must maintain a 36" setback from all single isles such as S Skylight Aprox Position gable ends. 510 N. State Rd. DATE VER. DRAWN BY CHECKED BY SYSTEM DESCRIPTION: (! Briarcliff Manor, NY Panel Layout Construction 04/18/2017 v1 BP DH -32 Photovoltaic Panels �Qf SE�YO / 914.762.7622 05/20/2017 R1 CCW DH -LG 330 Watt UL A5 Q► P,y 12L sunriseso/arllc.com Borsen Residence 09/5/2017 R2 CCW DH System size _1805 kVVyACC SYSTEM �h�� Bv�* 2el 305 Birch Lane Array 1 Array 2 91 mCUtCIIOgUe NY 11935 cr -Azimuth:187' -Azimuth:187°Solar -Tilt:20* -Tilt:T ss� PANEL LAYOUT Sect. Block Lot Array 2 �' SOLUTIONS -Azimuth:100* �982oa' CONSTRUCTION JOB#17-24 -Tilt:8° 'O�O� P�' PLAN NORTH [217"] 4'-5" FRONT OF N [53"] N HOUSE wWE 2'-1.. 10'-94" ., 0'-94 [25"] [129 1/4"] [9 3/4"] V V ►�V E EAST SIDE OF S HOUSE 0'-114" [11 3/4"] U WEST SIDE OF HOUSE SOUTH BACK OF HOUSE Setback Requirements 3.. 26'-44[316 3/4"] [340"] Fire Clearance Path Solar Arrays must maintain a 18" setback from all ridges, hips and valleys or surface that abuts another adjacent roof. _ Solar Arrays must maintain a 36" setback from all single isles such as gable ends. — 0'-114" [11 3/4") 510 N. State Rd. DATE VER. DRAWN BY CHECKED BY SYSTEM DESCRIPTION: Q� NEl�/ Panel Layout Detail Plan -32 Photovoltaic Panels Y Briarcliff Manor, NY y oa/ls/2017 vl BP DH �� p 7) -LG 330 Watt UL A5 Q. JOSFP / 914.762.7622 05/20/2017 Rl CCW DH Q, a� y �� ,/ BUYSen Residence System size 10.56 kW DC SYSTEM CO ,`� dv^ *\ S � 292 sunrisesolar!lc.com 09/5/2017 R2 CCW DH -8.64 kW AC 305 Birch Lane Array Array r- ti"ri' rn -Azimuth:187° -Azimuth:187° li ~ Cutchoque, NY, 11935 -Tilt:20° -Tilt:7° Sunrise Solar Sect. 83 Block 1 Lot 29 Array 1 PANEL LAYOUT SOLUTIONS -Azimuth:100` a9g�ob DETAIL PLAN JOB#17-24 -Tilt:8° � Q�' CLAMPING RANGE 40.00�� 0.00" 0,00��____y Notes: 40.00" OFFSET (TYP.) 1-1/4" 1/4" 1/4" Rafter attachments NOT to exceed J . 48" o.c. horizontally JUnCtIOn Rafter attachments NOT to exceed BOX 0 36" o.c. vertically LU SEE Solar Stagger rail every other rafter r') LU LU NOTE Panel 16" o.c. rafters CD u Co (Typ.) v 1 i1 M a Proposed Solar Panel Modules, U) Lu Mounted in Portrait or Landscape 2x6 Ridge Beam iV� '� U as noted.Configuration e Univac II Q + Rails.Install as per Detail and Asphalt Shingles Cables _ 1 Rail Unirac Installation Manual. (Typ.) Anchor Points @ Plywood Sheathing 48"Max.Spacing, 2X6 TD Wood Framing 00 SEE 00 Flashing Typ (see Detail) 12 .37 Non Consistent Spacing r� 4 NOTE (Typ') 66.38" I i Inverter V� co (Typ.) J m \ Q r, a H +) W !! Rafter(Typ.) PITCH 4.37 - 200 LLJ rrn LU a , f (Required ROOF SECTION- ARRAY 1 Lu 1 to } embedment N.T.S. a NO GAP of lag bolt Proposed Solar Panel Modules, o _ into rafter 2' W -, t0 I 1 Mounted in Portrait or Landscape 2x8 Ridge Beam Depth= 1.57" V I as noted.Configuration on Unirac 1 Rails.Install as per Detail and Asphalt Shingles rV rl w _ Unirac Installation Manual. Uj co Plywood Sheathing O I ~ 48"Anchor Points @ Spacing, @ 1 To O O.C. Framing Solar Pane ,--� U Typ.(See Detail) Non-Consistent Spacing i LG NEON 2 series i 12 '1.47 330W-A5 N.T.S. � I M %p j PITCH 1.47 - 70 F1ROOF SECTION- ARRAY 2 W rV� co i N.T.S. \ Q aProposed Solar Panel Modules, l!1 w I Mounted in Portrait or Landscape 2x8 Ridge Beam `—' U as noted.Configuration on Univac \ -- Q Rails.Install as per Detail and Asphalt Shingles M W �+- r/ c Unirac Installation Manual. ,-�CD W tp Plywood Sheathing Q_ i + Anchor Points @ 2X6 TD Wood Framing 48"Max.Spacing, Typ.(See Detail) @ 16"D.C. Non Consistent Spacing NOTE: FOOT SPACING NOT TO EXCEED 48" STAGGER FEET BETWEEN ROWS. 12 '1.69 LG 330 W-A5 PITCH 1.69 - 8° RACKING LAYOUT-ASPHALT SHINGLE ROOF ROOF SECTION- ARRAY 3 N.T.S. N.T.S. 510 N. State Rd. DATE VER. DRAWN BY CHECKED BY SYSTEM DESCRIPTION: sof NEW DATE La�IOUt Plan 32 Photovoltaic Panels �OSEP S � 3\1 Briarcliff Manor, NY 04/11/2017 Vl BP DH -LG 330 Watt UL A5 Q� /y O� 914.762.7622 05/20/2017 Rl CCW DH -System size -10.56 kW DC SYSTEM CO sunrisesolarlIC.Com Borsen Residence 09/5/2017 R2 CCW DH 8.64 kW AC * A� ��� 305 Birch Lane Arrays Array '_ 9 " . t. " fn -Azimuth:187° -Azimuth:187° 0 I ell RACKING NY, 11935 -Tilt:20* -Tilt:7* RACKING SOL UTIONS Sect. 83 Block 1 Lot 29 Array 3 o s820b \ LAYOUT -Azimuth:100° JOB#17-24 Tilt:8° FES PLAN L-BRACKET r �t Unirac Racking / Photovoltaic Panel 5/16'X 4"STAINLESS TOP RAIL STEEL LAG SCREW NOT TO SCALE FLASHING 5.25"-5.95" 4"-4.7" �O SUNMODO Photovoltaic Panel FLASHING DISC O0 _-'MIDDLE_/BOTTOM RAIL 'NOT TO SCALE ` FLASHING DETAIL NOT TO SCALE Unirac Racking INSTALL WITH GEOCELL 510 N. State Rd. DATE VER. DRAWN BY CHECKED BY SYSTEM DESCRIPTION: Of NEW S/ Rackin Detail Plan Briarcliff Manor, NY g oa/11/2017 v1 BP DH 32 Photovoltaic Panels .� yQ �OSEP 914.762.7622 05/20/2017 R1 CCW DH -Sy 330 Watt UL A5 o ��`>c� Jy� �,� S �4 %9un v sunrisesolarllc.com Borsen Residence 09/5/2017 R2 CCW DH System size =180 56.64 kW ACC SYSTEM * 0- 305 Birch Lane Array1 Array2 wm �./'� -Azimuth:187° -Azimuth:187° () LU Cutchoque, NY, 11935 -Tilt:20° -Tilt:7° r 901,91111110Sect. 83 Block 1 Lot 29 Arra 3 :� RACKING SOLUTIONS -Azimuth:100° ``� 9s20a �' DETAIL JOB#17-24 -Tilt:8' �'' PLAN G� BIRCH LANE Qa 0, �>/1 N WFEE O S NORTH BIRDS EYE 3D VIEW FRONT OF w HOUSE UTILiTI NETER =DESCONNECt D Ground Access front yard Ground Access roof height loftf side yard p a ` roof height 10ft f BIRDS EYE VIEW EAST 4 SIDE OF HOUSE Ridge ; ' 4 WEST Q SIDE OF a Ground Access HOUSE rear deck ill o roof height 12ft t Gate o .' T Ground Accessrear yard yard ° LEGEND - roof height 10ft f Gate Wood Deck 3'Fire clearance .ItI.II- \\ Pathway —�4 Ground Access Location Roof Access Pool to Ridge Vent �Z Ridge Vent SOUTH o ar BACK OF a `" � solar Panni Area HOUSE N 510 N. State Rd. DATE VER. DRAWN BY CHECKED BYof IN W 9�5 7 SYSTEM DESCRIPTION: Fire Access Plan -32 Photovoltaic Panels ,OS fP Briarcliff Manor, NY 04/12/2017 Vl CCW DH -LG 330 Watt UL A5 01 T J 914.762.7622 05/20/2017 R1 CCW DH � Borsen Residence -system size -10.56 kW DC SYSTEM CO `+ sunrisesolarllc.com 09/5/2017 R2 CCW DH -8.64 kW AC S � 5 305 Birch Lane Array Array -sem m -Azimuth:187° -Azimuth:187° Junin a ZULU Cutchoque, NY, 11935 Tilt zo° -Tilt:7° I SflLUT101VS Sect. 83 Block 1 Lot 29 Array �' o FIRE ACCESS Azimuth:100° 9s2oa� PLAN JOB#17-24 -Tilt:81 . r-------._.,_._-,._._.�.. ! LG 33OW LG 33ow LG 330# EXISTING ! ! UTILITY METER DEVICE 52-IT , �•'7�- •��+ .•.4�, � Solar AC Combiner Panel , ._ Enphase AC Nema 3R 60A Rated , Q a #6 THHN/TH WN-2 with 120/240v 1¢ #10/3 0.omex&#8 Ground ! ,„ ,.,•, •„ ! #e Grid.in Conduit No addtb N eak n o h ! a40atl 0o Spiepec"` , t $2. szeo szso MAIN SOLAR AC For wiring n1n5 Over ! OLADECIt , DISCONNECT 60 R.In length BOX All exposed ! EXISTING 60 AMPS FPAME please use#8/3 Romex ^� ^•• ^' ground to be#6 ! 50 AMPS TRIP 20A 52-IT-1 and#8 Ground 100 AMP AC 120V 14, SOLAR u , DISTRIBUTION PRODUCTION PANEL METER N L1- � ease _ ease ease. •••• ; 2P G Line Side Taps P • Circuitl-10 LG330WULG4BOB Modules with Enphase 52801nverters 1 ! Ll u ! J N - - - Jam- ea se N.. _ ! AE x 1 9�r.vd a m ee#6( 20A 52-IT-2 (ryp,) TER6•rIATON , G G . u ! ---- --1 o--#6 THHN/THWN-2 ! I -L- -•'•_ _ ! ARRAY 1- ROOF TOP„ - --- - �----------------------------------ease..---------. Grounnq ____. Gnd. N Lug j !20A 52-IT-3 r----------------a-------------a-----------------------Be---Be---- a I - W33ow LG 33OW LG 33M � r;i,.a rd I i Irnversible Crimp To I Not°N.utral I,-11r. h Groundlnq Electrode r"°t°rW". Ll „ Conductor c• j , I ' ! ' 15A Esm nvo Sno 1 Envoy Data 0.i All exposed ! l ground to be#6 ; Ef ••••�- ease. , Gntl. N i ®93 ` i Circuit2-6 LIS 33OWULG4BOB Modules with EnphxseS280Inverters ! #6 CU B-d.d W R-kinq. ! I , NI..P.sed 9—Z W 6e 06(Typ.) TB­TOR ! y , tr--#6 THHN/THWN-2 ARRAY 2- ROOF TOP ! LG 330W LG 33OW LG 3Ww , �__. _--ease_— •00I ! ! #6 THHN/THWN-2 • ! � I ! S2ao 62b0 '.5280 ; LAD / Photovoltaic Labeling Legend: j BOX "� ^ "� ground tbe 89L SOLARi — — { ••••�— i DISCONNECT ( j dreuit 2.8 LG 330W UL G4 BOB Modules with EnWarning-Inverter phase 52801nverters ElBond.d[.Rackln9. TERMXATtxa ' AE ezp.s.d 9,ev d W 1,e#6(Ty P.) V,p(r1T3Do ! Output Connection NOT Overcurrent;: . —#6 THHN/THWN-2 ARRAY 3- ROOF TOP ' © ------------------------------a--------------------------------a WARNING-DUAL P. Second S.—C is A Photo voltaic System r---a--------------------------------eR----------te � to 3IOW LG 330W 1G 330W , OF NEW y �sl'' �OSEP 'Q : ADEIX _ 5280 —'y 5280 52.0 ��O ! Sox n.. n. All exposed �1 ! ground to be#6 SOLAR / .. • • p w -- --- -- — — — 1 000 DUAL • WARNING r POWER Circuit 3-8 LG 330W UL G4 BOB Modules with Enphase S280 Inverters ! SECOND ``!)' / /\ 16 N atnd.d te Raking. El PHOTOVOLTAIC • • • w� 09 Atl.xpsptl 9rwM b M t6(ryP.) ; SYSTEM U\p #6'"""'T"W"'2 ARRAY 3- ROOF TOP i v EQUIPPED WITH 46----•.----------------- n---•--------------------- ,I RAPID SHUTDOWN 510 N.Stade Rd DATE VER DMwa•T cs—o ay REMARxs Circuit Calculations: System Specifications: Legend:3 Wire Electrical Dia ram 9 Neutral-White Wire _ BnarciH Manor,NY 8 osn47am M Max.ui I Calcuverters per ons:d-it o Amps ot�D Taal system:911.76'27622 17 oN n t 3IM W 3ON ".ls l.r swm;soa Orem[14 x 270 Watt Inverters Max Output=3780INat[s 32 modules x 330 wan kW DC sm Borsen Residence Exisitnq Service Ground-Green Wire 3780 W t 240V=15.75 Ames 32 1—x 270 W AC=8.64 kW AC 305 Birch Lane 15.75Amps x125=19.69 Amps L3 Blue Wire Data Communication Wire Cuteho ue,NY 11935 Use 20Amp OCPD Nominal Aevatege-zdov 9 61 a.Acdrtent-3600 �fISe lar TOranzx270=e,64owAc 't"w' L2 Red Wire ------------------- Sensor or Switch Wire ELECTRICAL Sect.83,Block 1,Lot 29 SOLUTIONS 8.64 Use z4ov=3600xl.zs=4s.ao WIRING loe n7-z4 Use 50 AmpO�D Ll Black Wire Photovoltaic Label DIAGRAM