Loading...
HomeMy WebLinkAbout42289-Z ��4�g11FF0(,�Ca� Town of Southold 2/14/2018 z� P.O.Box 1179 o - o • 53095 Main Rd 4A, �0 Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39511 Date: 2/14/2018 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2015 Yennecott Dr., Southold SCTM#: 473889 Sec/Block/Lot: 55.4-19 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 1/3/2018 pursuant to which Building Permit No. 42289 dated 1/10/2018 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels on existing one family dwelling as applied for. The certificate is issued to Gregg,Douglas of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 42289 2/6/2018 PLUMBERS CERTIFICATION DATED Authorized Signature FFutx ` TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE o. . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 42289 Date: 1/10/2018 Permission is hereby granted to: Gregg, Douglas 2015 Yennecott Dr Southold, NY 11971 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 2015 Yennecott Dr., Southold SCTM # 473889 Sec/Block/Lot# 55.-4-19 Pursuant to application dated 1/3/2018 and approved by the Building Inspector. To expire on 7/12/2019. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 Buil spector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. 11 2 New Construction: Old or Pre-existing Building: (check one) Location of Property: 5 y"52 r)� r)-n bell. �R[�1 d - House No. Street Hamlet Owner or Owners of Property: 60 Suffolk County Tax Map No 1000, Section �rj Block Lot l C _ __Subdivision_ Filed Map. Lot: Permit No. VW Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ A ignature pF SO�jj�®l Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 �Q roper.richert(a_town.Southold.ny.us Southold,NY 11971-0959 Q 1'1coUNT`I,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Douglass Gregg Address: 2015 Yennecott Drive city,Southold st: New York zip: 11971 Budding Permit#: 42289 Section: 55 Block: 4 Lot 19 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Sunation Solar License No: 33412-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency FixtureTime Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: 8.580KW Roof Mounted Photovoltaic System to Include: 26- Panasonic 330 Panels, 1- SE 7600 Inverter, 40A AC Disconnect. Notes: Inspector Signature: Date: February 6, 2018 0-Cert Electrical Compliance Form.xls OF SOUlyolo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION_ [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) REMARKS: 11 DATE INSPECTOR Yet Y Fisher Engineering Service D �Od� - � D PO Box 30 . Oakdale -New York 11769 FEB 1 4 2018 Phone: (631) 563-9028 BUILDING Alm. January 25, 2018 TOWN OF SO�OLD Town of Southold Building Department Post Installation Certification Subject: Engineer Statement for Solar Roof Installation Residence: Gregg—2015 Yennecott Dr, Southold Permit No. 42289 Installation Inspection Date: 01-24-2018 r, The roof mounted photovoltaic system at the above referenced residence has been generally observed to be installed properly in accordance with the approved plans and is certified by Fisher Engineering Services, P.C. to be in compliance with the minimum requirements of the Town,the 2017 NYS Uniform Code, 2017 NYS Uniform Code Supplement, 2015 International Residential Code (2015 IRC), Long Island Unified Solar Permit Imitative (LIUSPI), and National Electric Code 2014, and the provisions of ASCE 7-10. NEw ro�� h e Sincerely, r IL William G. Fisher, P.E. Licensed Professional Engineer Architectural Design-Residential-Light Commercial Additions-Extensions-Conversions Construction Estimates/Oversight-Expediting-Inspections FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (IST) H -------------------------------------- FOUNDATION (2ND) NO cA (C) a V1 CA gs ROUGH FRAMING& 1 PLUMBING .3 H INSULATION PER N.Y-. H STATE ENERGY CODE FINAL ADDITIONAL COMMENTS Cil o z m t� 1 O \ z d b H r ' � TOW,N'OF SOUTHOLD, BUILDING PEkMITAPPLIC-ATION.CHECKLIST BUILDINGDEPARTMENT' Do yowhave.or need the following,beforeappiying?- TOWN'HALL Board of Health SOVI'NULD,Nl'119 7E7� Csetsof Building Plan'sTEL:,(631)765-1802D Bf-�' > Planning Board approval FAX:(631),7§5-9502 4�10Aeck rvey SoutholdTown.NorthF t PERMIT�NO. 0 JAN 3 Septic Form N.Y.S.D.E.C. Trustees _ r,T.fi,{•s;r a 'C,O.Application F r).' ,,w,,7q �= Flood Permit Examined ,20 OF SOU TH®LD Single&Separate :Stonn4ater AssessmentTorm /0 `Contact; Approved 20( 1 y� �'> Mail•to°SUNatlon Solar Systems,Inc Disapproved c TO 171 Remington Boulevard,Ronkonkoma NY 11779 Phone'(631)750-9454 Expiration. ,20 BuMag4insliect6r, APPLICATION-FOR-BUILDING•,PERMIT Date. t. � 20_!L_ :INSTRUCTIONS a.This application MUST be completelyfilled m by typewriter of in ink and subnutted 1:64he'B'uilding Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of..buildings on premises,relationship to adjoining premises or public streets or areas;and waterways. c.The work covered by,this application may not be commenced before'issuance of Building Permit: d.,Upon approval.of this application,the-Building Inspector will.issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for,inspection throughout,the work. e.No building shall be occupied or used in whole orin part for any.purpose what so,ever until the Building Inspector issues,a Certificateof;Occupancy. f Every•building'permit shall expire if the'work authorized,has not co"mmericed'within"ITmonths after the date of ,issuance or has,not=been completed within I8 months-from such date.,If no zoning amendments.or-other regulations affecting the property have been,enacted in the interim,the Building Inspector may"authorize,in writing,the,extensiorrof the permit for an addition six months:Thereafter,•a,new pertnifshall be required. APPLICATION ISIREREBY,MADE to;the Building Department;for,the'issuance of a Building Permit pursuant,to fhe. Building>Zone Ordinance ofthe Town of Southold;Suffolk County,New,'York,and'other applicable:Laws;Ordinances or Regulations;for the°construction of buildings,,additions;'or alterations or,for removal of demolition as herein described:The. applicant agrees to comply with all applicable'laws,ordinances,building,code,'housing,code,.and regulations,andto'admit authorized'inspectorson premises and,In building for necessary inspections. .1 (Signature, applicant orl1iiame,if a corporation) SUNahon Solar Systems,Inc 171 Remington Boulevard,Ronkonkoma NY 11779 (Mailing address of apphcant), State whether,applicant is owner,lessee,°agent;architect;engineer,,general contractor;electrician,plumber or;builder SUNatlon Solar Systems,Inc-Contractor Name of owner ofpremises: p ---- - � s �e tax,ro or•atest f ee -- -"- If applicant is-a,corporaiion,signature of duly authorized officer. Scott Masktn-President (Name`and title of corporate'officer) Builders License No.44104-H Plumbers License No. N/A Electricians Licedse,No:33412-ME Other,Trade's•License No. 1. I:oeation of land:on"which proposed wrk willbe,done: HouseNumber' StreetHamlet, County Tax Map:No. 1000 'Section ,� Block- //"l Lot I I; M 0 Subdivision Filed Map No.. Lot 2. ,S,tate;ekisting use,and occupancy of premises and1htended use,and;occupancy of proposed.construction: a: Existin&use and occupancy Residence b. Intended-,use and occupahcy;Residence with addition of Solar Panels 3. Nature of work;(check which applicable):New`Building Addhiort__[2 _Alteration_ Repai"r Removal, Demolition 'Other Work smarPaw. (Description) 4., Estimated Cost, $24,978 Fee, $200.00 (T,o,be paid on flirtg'ihis application) 5, If dwelling,number of.dwelling units Number of dwelling units on each'tloor If garage,-number of cars '6.. Ifbusiness,;commercialor mixed occupancy,specify,nature'and-extent of each:type of use. 7. Dimensions of.'"isting,structures;if-any:Front Rear Depth' Height Number of Stories Dimensions'of'same,structure with alterations.or'additions:.F'rorit Rear Depth Height Number of Stories 8. Dimensions of entire new-construction:Front. Rear, Depth Height Number of Stories, 9. Size'of lot.Front Rear' Depth 10.Date of Purchase Name'ofFot`meeOwnec. -11..Zone or,,use district.in which premises are,situated 12.-Does_proposed construction violate any•zoning law;ordinance or regulation?YES_NO X 13.Will lot,be re-graded?YES NO X Will excess f 11 be removed from premises?YES NOX 14.Names of Owner of premises Douglas Gregg Address 2015 Yennecott Drive Phone No. 631-Z65-3996 Name.ofArchitect William G Fisher Address.Pe Box 30,Oakdale,NY 11769 Phorie No 631-7864419 Name of.ContTactor suNahon solar systems,Inc Address,+71 Remingtonaoalavam,Ronkonkoma NYPhone No. 631-750-9454 15'a.Is this property,within 100'feetofa tidal wetland,or a freshwater wetland?.*YES 'NO x *IFYES,SOUTHOLD.TOWN TRUSTEES&DZ.C.PERMI.TS.MAY BE'REQUIRED. b.Is,this;pr6pertywithin'3001feet of.a,tidal,Wetlatid?*YES NO'X *IF'YES,D.E.C.P-ERIVIITS.MAY'BE REQUIRED: 16.,Provide survey,to scale,witlf-accurate foundation plan and distances-to,p'roperty lines. 17..T£elevatiomai any point on property i's:at 10 feet.oebelow,must provide,topographical'data,on survey.. 18.Are there any,covenants.and restrictions with respect to this property?'*YES NO'X *JF-YES,PROVIDE A,C,OPY. STATE OF NEW YORK)- SS: 'COONT.Y OF Suffolk Scott Maskin-President-SUNation Solar Systems,Inc being duly sworn,deposes and says•ihat f s)he`is'the applicant '(Name of individual signing contract)•above named, (S)He is'the;Contractor '(Contractor,Agent,Corporate Officer,etc.) of saidowner or owners,and is duly authorized to perforin or have performed the said work,and to make and file this,application;; thatall'stitements contained in this application are true to.the best ofhis knowledge and belief;and-that,the'work will be' perforrned,in.the manner set forth'in the•application filed therewith: 3,Swm,to before me 11:14' day of 0 No ary Public re of Applicant VICTORIA M. WALKER (VOTARY PUBLIC-STATE OF NEW YORK No. O1 WA6319756 Qualified in fiuffolk County My Commission Expires February 23, 2019 I 1 Scott A. Russell ,�"°SU `k� ST�O�]l�I��l[�wA\T]E]k svPEzavisoR MAN SOUTHOLD TOWN HALL-P.O.Box 1179 0 53095 Main Road-SOUTHOLD,NEW YORK 11971 _ Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT INVOLVE ANY OF THE )EO)LLONVING: Yes No (CHECK ALL THAT APPLY) ❑ A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑ C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑ D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑� E. Site preparation within the one-hundred--year floodplain as depicted on FIRM 'Map of any watercourse. 110 F. Installation of new or resurfacedimpervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of .impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to,your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management�Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT: (Property Owner,Design Professional,Agent,Contractor,Othed S.C.T.M. 1000 Date. District 9 NAME: In�U11IGY ���lTl 1 Section Blbck' Lot \ �5 ""FOR BUILDING DEPARTMENT-.USE ONLY"*** Contact Information a Rekphove Numbed Reviewed By: 1 ) ` - - - - - - - -Date_�— PropertyAddress%Location of Construction Work: — e Neo(c �y Nue Approved for processing Building Permit. Y u�1�1 Pi Stormwater Management Control,Plan Not Required. F ® Stormwater•Management Control Plan is Required (Forward to Engineering Department for Review.) FORM SMCP-TOS MAY 2014 -- -------- - ---- - - - - - - - -- ------ -- ----- - ' o��,aFs�l/jyo • w �D Tows HA A{nex Telephone(681)765--11802 54875 Alain Road N e 19cler richertt own SOU41101a.hY.l1$ P.O.B=1179 Southold,NY 119714959 BU"ING•DE PARTME r TOWN OF SOU MOLD APPLICATION FQ,R ELECTR19AL INSPECTION REQUF...STED BY: Gina Marie Date; 01/02/2018 Company Name: SUNation Solar Systems, Inc Name: Scott Maskin Uc,ense No.: 33412-ME Address: 171 Remington Blvd Ronkonkoma'NY 11779 Phone No.:, 631-750-9454 JOBSITE INFORMATION: (*Indicates required information) *Name: Douglas Gregg *Address: 2015 Yennecott Drive, Southold NY 1'1944 *Cross Street: *Phone No.: 631-765-3996/631-338-0188 Permit No.. 8 Tax-Map District: .T 1000 Sec ion: 55 Block: 4 Lot: ,r....19 *BRIEF DESCRIPTION OF WORK(Please Print Clearly) 8580W Roof Mounted Solar Photovoltai system Including: 26-Panasonic VBHN330SA16 PV Modules. 1-Solaredge SE760OH-US Inverter W/Disconnect 1-60amp Single Phase Fused A/C Main Service Switch. (Please Circle A I That Apply) *Is job ready for inspection: YES l NO Rough In Final Vo-you need a Temp Ced lcate: . YES NO Temp information(if.needed) *Service Size: 1 Phase 3Phase 100 154 200 300 350 , 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYME DUE WITH APPLICATION PC— jU4WWesj for fnspectfon Form d� SO!/jyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road N Fax(631)765-9502 P.O.Box 1179 G • Q Southold,NY 11971-0959 'Q a c®UNT`I,� February 12, 2018 BUILDING DEPARTMENT TOWN OF SOUTHOLD SuNation Solar 171 Remington Blvd Ronkonkoma NY 11779 Re: Gregg, 2015 Yennecott Dr, Southold TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: NOTE: Post installation certification letter required stating the panels were installed to the roof per NYS Building Code Electrical Underwriters Certificate A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 411184) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 42289 —Solar Panels • .' t i.. Y ;yam; •- '�.' ..r � v)!�s .• rt. �•..'�!*,�a.�-�• `- u '- - -_ -,y.iNr • - Lit • �� ' -- .�, ' . - . -• �'-'� .. : �' . ' . ..:;-,�. )} s RRAUTHIMMUD ALMALiLryv OLt ADvgwgjb i IV sill 2�� ~�. �, /i rr C P TO THIS SURVEY JS A VIOJATION OF 3ECT10N 7M OF THE NEW YORK STAB � tii �h'C.3. bd EDUCATION LAW. ,� II coPrEs of THIS SURVEY ASAa NOT eEAIIRlg 1 1} JA,, or Gla,ed/a ��rPc�(/ M LAND SURvMa s IAC(»SEAL O! ut 2} �7AukN pE�CN T U A VALID SHALL Cor cvNSJDEe�} .CYN�C.(Z. QiSyTt(�� -+ +� CRAB GVA?J►.SCLESITZICATMKMONSIML�1 `f j M-ELY TO WA PMOK FOR WHOM THE suffit jI 'Jf ��o IS 24A.T-SP A1:0©1,HHS EFHALF TO 71* zi � ` // lift-COMPANY,GOyE�?{V UNTAL AG04LY UM!MG INST1TUTJ-L'L USUD HERE M AND �f �,1ldLEPr�)d 8 tRe.t'�. :� riE ASST;NIBS OF THE LENDING INSTF T'uTV)LL GU,4.P"EES AXE NOT TgANSFEItAK= V oot" -'O.%MTIONAL 24STMMews ns nn%ctn. - 1 MA © f'A p+J J�IDbSE} >xfiX. © r ff r d tf` ' L R IV b 3 511-AVEYill f0A :}:. L✓ 1�"'� - � j " _ ; . Fes' j 3tT�p1'� Af 745.2T Tr TDIVM' OF 56 1171/0 4 0. N.Y. all a l rI1W CV ! T 1` t L TTrLG NO. M Tras3-00160 'TNS' T1 a rTu*gAAiv �5 ;t l�fC-�4151Y, ` MOTS 8 = /A01v PIPE 445 [lit Y+cJ Ji?"-fid, 1'9813. Liar Ryid>8shl SA JY& Rcm; Tfl YX1fN,t't 47T FRAX" PILS 1 IN TIM $11fFdtX zd0Xf'Y CLEI991 dFFI Z LT6 1AEP lif 5187 + Ltt_tNSjK/ tEffo SVRVE-Y4#.4S SliFF. CU7-AV/AAiP -CA71A=1M.0-45--44 flF�E�NPflR3"r �Sffl� 1�t K14 New York State Insurance Fund Workers'Compensation&Disability Benefits Specialists Since 1914 199 CHURCH STREET,NEW YORK,N.Y.10007-1100 CERTIFICATE OF WORKERS' COMPENSATION INSURANCE 0. rrr �❑_ ^^^^^^ 271875558 SUNATION ROOFING SERVICES INC 171 REMINGTON BOULEVARD RONKONKOMA NY 11779 . Scan to Validate POLICYHOLDER CERTIFICATE HOLDER SUNATION ROOFING SERVICES INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 22160 670-2 150688 01/01/2018 TO 01/01/2019 1/2/2018 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER:460692523 U-26.3 SUFFOLK COUNTY•DEPT'OF LABOR,, ! } LICENSING&CONSUMER AFFAIRS, CONTRACTOR it SCOTf.A'MASKIN i ..-.I.... BUSNESSNAME' This certifes that'the SUNAVON SOLAR SYSTEMS INC' bearer is du(y� licensed bythe udimeNumeerli..d, ! County,of.Suffolk 44104-H '03!06/2008 ccmnY=nnn: Exra+Ara+°AT' '.0310.172018 > I 'SUFFOLK COUNTY DEPT OF LABOR, 5' LICENSING'&'CONSUMER AFFAIRS MASTER ELECTRICIAN - - -t -NAW -SCOTTA MASKIN This certifies that-the a"s" S"^"E bearer'is duly SUNATION SOLAR SYSTEMS INC licensed by the County of suffolk "`°"""°""" - Dab 1-..d, 3'34:12-ME osi2ai2oos Commlubmr E%PRAM NGATE' t Ofil01l2019= ELECTRICAL APPR VED AS NOTED INSPECTION REQUIRED DATE: B.P.# FEE: BY: NOTIFY .BUILDING DEPAR AT 765-1802 8 AM TO 4 PM FOR THE j FOLLOWING INSPECTIONS: kL FAIN STORM WATER RUNOFF 1. FOUNDATION-- TWO REQUIRED FOR POURED CONCRETE PURSUANT TO CHAPTER 236 2. ROUGH = FRAMING & PLUMBING OF THE TOWN CODE. 3. INSULATION 4. FINAL CONSTRUCTION MUST 'BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODE, AS REQUIRED AND CONDITIONS OF soul H ARr I r, iVRffTEES N. OCCUPANCY OP USE IS UNLAWPI.." WITHOUT CEPTf r . 'AT► OF OCCUPANC Fisher Engineering Services, P.C. PO Box 30 • Oakdale •New York 11769 Phone: (631) 563-9028 December 29, 2017 Attention: Building Department Subject: Engineer Statement for Solar Roof Installation Gregg Residence- 2015 Yennecott Drive, Southold,NY 11971 I have verified the adequacy and structural integrity of the existing roof rafters for mounting the solar collector system (photovoltaic system) and its installation satisfies the structural roof framing design load requirements of the 2015-International Residential Code and the 2017-New York State Uniform Code Supplement, Long Island Unified Solar Permit Imitative (LIUSPI), and National Electric Code 2014. I have reviewed and certify that the manufacturer's guidelines and equipment for the photovoltaic system for the above residence meet the requirements for wind and snow load and that the roof structure is adequate to carry the new loads imposed by the System. For the installation of the solar mounting,the rails shall be securely anchored to the rafters utilizing lag screws that have been designed for wind speed criteria of 130 mph and snow ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and geographic design criteria are not applicable to this solar installation. The installation shall be in accordance with the minimum requirements certified by this letter. Tie existing roof rafters are 2"x8" on 16" c.c., with an actual span of 12'-11" with plywood roof decking and one roof shingle layer on the house as shown on the drawings. There are no structural modifications planned or required for the existing roof. I hope that this letter serves and meets with the approval of the Building Department. Sincerely, r o�NE",�r� William G. Fisher, P.E. Licensed Professional Engineer ~ Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections �...( �G:;i'ai- sola - ' M . ,.,.z.., z•; ®IarEdge Single Phase Inverters for North America �,-�' � _�,p:�`y,.' s.. .a"i•Y,a. :+t?X"z°'y!`H n,.. !do-_%,�gs .�+ } nP. Yi, ,+y ,E- .3y� �. •4 [,:�,�>�.w w...�v� ;"'v,"l'�' <i::'!`',a ,,,,y'�µ"'�'pxi,>X'M�h«-X •, � xa�f"'� SE3000H-US/ SE330OH-US / SE5000H-US / SE6000H-US 101 ,''�"w.:�;•rk,.,�',d4'� :µ"5.'�j�,'. k $^rS"Yr�':w`�+,.."q�'y£.i::;�,sfl3.' i'%�e.`i�'fy..� �_ x,,.gym, Y.'F'�.•t.,.. "" •'P "Z�'ti- •�• i '- '� a t ���- k ``''6''.iv,'••�." .,u,'.e,.x e �.p - •.••. ... .,R`.-....s-4,� �.,F,a. p.ri: '§` •s. 'P- ,-" � �,..v�"5•.:�.�^;�m ���v. �`'`�fi;` e` -q= i. ate.'^ry"-'�rJ'_"a";k:" , I ..u.._,_.._.. . '�. A- "-4 iae� '. :ff.'s. i.;",o .k F('w:'g:i5:.• ,',vu`'.:> .aetVry{=!. ,Yr.:� ,'� 46,< E�.',.y,: ,w:�,�,�e'�_t�t�`. ,:'';✓i:'.�. 'S'^a"a, " '�•L: ;�.',.s,i,:�;'.:e,kS,de-�;�': 'fie„ . ., � •�R•.,,�, - x.n.5'Mw- •.;°. R�+t°.""''. ,. ;L '� ,z,�.;;�.�_. ;tea. ., , ,� �=��,;,j.,:: ';�+s�` .�^' ,;3,�?ar?v� ai,''m"""r4;""-c�'�-�' '"&.�a','L°xs:#�; *�,1.:: qc ,<,•� .« ' .. '6 w y. '��-'r".%q" fes• o-K-.'n.,y".:P,T S.,, 'a.r„}f'��,d, ��a,;,c '�.�''v�,.i.n� � ",. ''ee�"�i: 5�,"-,�'$r > Ia > ;q � x"& '- •` Ey,�,�.�•'�r •_-yiVy'y, °•�v,:�ep xs'Y n'M%q "�,r _. ear_ �a.a�)..-' ;s"�v '` 'psi ,'..�,p2��„; -.:�r�;""�=tom'"" ;' ..;t.;n'au'�,;� .::'r,=';�w�aa•,°;�y�", _ �` �_ ;`�! s E, -,a:;;Y�iS;' x:ghvlk.a-'y-;�ac•,�,.'.r,.GVd`v.s'a'w-ex,.t?an'^,�3E',°«".rN". r`s,"�: :x; � , amt ,'v.:""�i r, "n'y�•;"'!' \v�Ag''.q,o`,"'.:,„. §. ,. ":�„ r'. . _. ":°_.+.�.,,�..,,,,�,,yd°w. �� _ `"'+�� ,s'�4° w��•,ffi,,:.4 �',a.s°'*-rsr'a=�4 x * �: „,��xr•�`'a°,;°.q.�x '.,rt3�^�s,,��<�'��.,dtyw'��r�%.Me�-•Fw< � d _„� ;.^',�'�.".r'x `� ^;;:'�s'."t ..w. �x k"a” �,s'Sa'";"�.:ns°.x'"ha,: "s'ti's:'�n'�d�^'.•���^::;=�..> :;a:,:"a�,�ae y ,•.Ew"a T" <`:.'•'.'4.;rd,''",'a -`is ,�^M,� a rr.r< :,fir`''-;i :r"$bHx'r`'a,.9;fin:, * i "i:n-:., i '°.«. _. ., •'u:�S?-'t'',z:.';:r:•.r i�%�".r.' ""-". ,h'afi 'at''� i.> ��:.�' sx.t+. y» •�� � ..��y„gA,..;,k_ ,:-' ,� _` %',�.x.,'rs"�t,*"„�,;�:7R`.:��..,•�, s;4, �." ,'':.t.A;:?�*'"�".:,i. tAMLx• fix: ,*"#.�w;,ie ..-a.• .k4: ;`'t. ye.¢.�-- „H' -:`,:, ;, r- b;_ ,i,„3 ro •."r-, x,'; .k�`.. .,o, '-�'� is �'',,. *}e, I � ., � rs � e> _%�; :"'�.m '=>'�''�„ty-,a'=, o.. _'� :v+a='�a�vt '"�*`�'. „ifi;l;+:.t,"'y, wd4 .r'„6•t� a .. '"' ,cy , �.s'^ .e .•.."ti°e:� z'" '<xg':r {", a- ,,y*i �sy,:=`Y- :. ;its:• '; '"- •'' j' r .. ., .�^'#w.r^.� �,'<• ;a'r:- .i"' :a;s,".�.°#<."'�s*�r<, t-e:,' >ry�•'rq° ;a. ,#�`+ "„''�� ^rtc"k-;: . k,1,'.x` x ..r.+4<... .: •n. q.��: t- y...,�et..$. { .+y-'.x:;b:'«•°, 'p 's'eF._,".j3° ,„k,4 �.0 %S':J+... IV�f',yT.,' Z;': s T '. "a a:` rc-x**. ' _ ,",�`'.•;:S;AN,^' _P s.....:,�K,N,>,S,N. 'ate,Y".'ro "'w.r: 4", '�a =-�,'�,�,,.,.a; - :�'9w.:`"�s',pc4�;v�..w f,"'��,.�'.°`" ,. �z m�•�.<,xA�..J '�.-'rm. :, 'd,, ���.�a; w ��5� -,.>";Gti _ 't "�.�'+`pia• *F"- - 'z''.::.�5,' -a.�,� ?�.r'.� .,a .. .,ti,: rv,Y o r- � , fir`" m ,{;fit 3.� '±". - s'; � �, .,g +. �'�,�:,;• -�„ra"•,� ,i ..��.�, d3"`,:�”-�"D*at€4,.' ':xd"'��'",>°s�" Optimized installation with H = ave'technology Specifically designed to work with power optimizers Record-breaking,efficiency Fixed voltage inverter for longer strings ® Integrated Arc Fault protection and Rapid Shutdown for NEC 2014'and 2017,per article 690.11 and 690.12 UL1741 SA certified,for CPUC Rule 21 grid compliance g Extremely small and easy to"install-outdoors or indoors ® High reliability without any electrolytic capacitors a Built-in module-level monitoring wave ® Optional:Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTH AFRICA-BULGARIA www.solaredge.us solar ® � . . ;% Single Phase Inverters for North America SE3000H-US/SE380OH-US/SE5000H-US/SE6000H-US/SE760OH-US SE3000H-US SE3800H-US SES000H-US SE6000H-US SE7600H-US" OUTPUT Rated AC Power Output 3000 3800 5000 6000 7600 VA ................................................... ........ ....... .................... ............. Max.AC Power Output 3000 3800 5000 6000 7600 VA ............................................................ ....... ....... . ............. AC Output Voltage Min.-Nom-Max.(18B-208-229) ✓ Vac ........................................................ ................... .................... .................... .................... .................... ............. AC Output Voltage Min.-Nom.-Max.(211-240-264) ......... ......... ......... ......... ......... .........�......... .........'�......... Vac ........................................ ................ . ............. AC Frequency(Nominal) 59.3-60-60.5(1) ................. .....Hz ..... ......................................................... .................... . .................. .................... ... ... Maximum Continuous Output Current 208V 24 A Maximum Continuous Output Current 240V 12.5...... .................... ... ..... .. ..16 21 25........ ........32........ A ..... .�....... ... � .... .. GFDI Threshold ............. Utility Monitoring,Islanding Protection, Yes.................................................. Couniry Configurable Thresholds ( INPUT, Maximum DC Power 4650 5900 7750 9300 11800 W ...........Powe..................................... .................... .................... ........Yes........ .................... .................... ............. Transformer-less,Ungrounded ............................................................ ........................................................................................................ ............. Maximum Input Voltage 480. c ............................................................ .................................................. ............................ .................... .....V........ Nominal DC Input Voltage 380 400 V dc Maximum Input Current 208V iii...................... _....... 13.5...... _........ Adc .... ............... ........................................... .................... . .. . . .................... ......... ................... ............ ................... Maximum Input Current 240V(z) SS 10.5 13.5 16.5 20 Adc ................................I........................... .......... .................... ............. Max.Input Short Circuit Current 45 Adc ............................................................ ............................................................ . ........................................ ............. Reverse-Polarity Protection Ground-Fault Isolation Detection 600ku Sensitivity ............................................................ .................... ....................................................... ............. Maximum Inverter Efficiency 99. I 99,2 % ..............................a........................... .................... ....................................... ............. CEC Weighted Efficiency % ... 99 ............................................... .... Nighttime Power Consumption <2.5 W 'ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet.ZigBee(optional),Cellular(optional) ... Revenue Grade Data,ANSI C12.20 Optional(') . ........................................................... ............................. .................................................. ............. Rapid Shutdown-NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STAN DA R D.co PA P LI AN C E Safety UL1741,UL1741 SA:UL1699B:CSA C22.2,Canadian AFCI according to T.I.L.M-07 ............................................................ . .................... ............. Grid Connection StandardsIEEE1547,Rule 21,Rule 14(HI) ............................................................ .........................................................................................I.............. ............. Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 0.75:1.' Conduit/146 AWG ... ............. . ................................................ ................... DC Input Conduit Size/#of Strings/AWG Range 0.75.1,' Conduit/1-2 strings/146 AWG ...................... Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 in/mm .....g.................. ... ....................I.................... .. ... Wel ht with Safet Switch 22/10 ....25.1/11.4 26.21/.11..9 Ib/kg . . . .... ....... . . ...... .. . .. . . Noise <50 dBA Natural convection and Cooling Natural Convection internal fan (user ............................................................ .........................:..................................................I...... ...replaceable)... ............. Operating Temperature Range :13 to+140/-25 to+60(")(-40°F/-40°C option)(5) F ....................................................... . ........................................................................ ............. Protection Rating NEMA 3R(Inverter.with Safety Switch) For other regional settings please contact SolarEdge support (Z)A higher current source may be used,the inverter will limit its input current to the values stated Revenue grade Inverter P/N SExxxxH-USOOONNC2 Power de-rating from 50'C (s)-40version P/N SExxxxH-USOOONNU4 tn - •� •-•®•: a ;•: i solar,=@ z SolarEdge Power Optimizer Module Add-On For North America OP250-LV/ OP300-MV/ OP400-MV/ OP400-EV r'4A P Y L t qv it� ix'4�'di•5v.,�'..}'., j�,,- 'a {- __ Y „ - - _`^K r0µ>x4 y-+ `^1.-, x�Y�%`Ya^�• - x` u'� SJ'.}�,1'}f y�~�` sy.. S•. ti P aV� w' - O-Y .1 Baa. .P at"th _. em" , P to':25 a inose energy Superior-efficiency'{99,.- ' }' Miti tes.aiL es;`of module kr match losses,from rrianafacturingtgle ance to;par,ai shading = tYP; Fiexibld sy gem'design for maximum space utiliiatiori .- .Nextgeneration r'naintenance with niddeile-leuel rnani ; toi'tng+ Module4evelvoltage shutdown for installer and firefighter safety.'; - USA GERMANY ITALY FRANCE JAPAN CHINA ISRAEL - AUSTRALIA www.solaredge.us 09%41% ea, .1`13ular, _ YolarEdge Power Optimizer r•. -3, .7 Module Add-On for North America 0P250-E V/ 0P30040/ OP40040V/ OP400-EV OP250-LV �OP3Q�0-PAV OP400-i!,tiV 3- OP/;00-EV INPUT � - �.. Rated Input DC Power* 250 300 400 400 W Absolute Maximum Input Voltage(VOC) 55 75 75 125 Vdc MPPT Operating Range 5-55 5-75 5-75 15-125 Vdc Maximum Short Circuit Current(Isc)of connected PV 10 10 10 7 Adc Module Maximum DC Input Current 12.5 12.5 125 8.75 Adc Maximum Efficiency.. 99.5 /o Weighted Efficiency 98.8 Overv_oltage Category_ _ _ _ II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current ��—_� 15 Adc ..,. Operating Output Voltage- _ _ 5-60 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer �� — 1 — Vdc STANDARD COMPLIANCE -- EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 Material UL-94(5-VA),UV Resistant RoHS _ _ Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions(W x L x H). 143 x 210 x 45/5.63 x 8.26 x 1.75 mm/in Weight, 450/1.0 gr/Ib Input Connector - - - - - -- - - MC4/Tyco-/H+S-/Amphenol--H4' Output Wire Type Double insulated;6mmz;MC4 Output Wire Length 0.95/3.0, 0.95/3.0 1.2/3.9 1.6/525 ; m/ft Operating Temperature Range -40-+65/-40-+150 aC/'F Protection Rating IP65/NEMA4 Relative Humidity 0-100 •Rated STC power of the module.Module of up to+51Y power tolerance allowed. PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V INVERTER Minimum String Length(Power Optimizers) 8 8 18 Maximum Strin`g Length(Power Optimizers) 25 25 50 Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths or Orientations Yes j'i� e _, . 'F . y''�' ,�^. Sf � e'X;• .+ ': .. x p;�,p .K ...,n.,da^� t' 4........ Hr - ... 1 . r.. '}: -f - ... ..r � a ..- mow.✓Wfi/' D, YS— a'A i�•� .r :^�. .. �,.�f _ $} ,�='°:✓�' 134,],-�-ar'ay'.�,1' �t, '` "'_�✓ - o-,,.t .^i- ,.Xn. ;x:F n; d,- ..`:.. w v SOLAR SYSTEMS ` R1217 Montauk Highway,Oakdale,NY 11759 _ .a M19m .. � 631-750-9454� www.sunattonsolarsyst ems.com4 - s = ) ! ,..-rt,r ,.. N..-,.---• .-.-,: • ....,mom•;._- - h•.1 The SnapNrack line of solar mounting ; r �. systems is designed to reduce total installation costs. The system featuresr technical innovations proven on more than 20OMW of solar projects to simplify a ' installation and reduce costs. 6 Y`3 Flashed L Foot Simplified 1 SnapNrack Series 100 Flashed L Foot Kit is an innovative solution to provide a long lasting watertight seal over the life of the system.The Flashed L Foot provides a single fastener flashed to an attachment composition Flashed L Foot,-In 3 Simple Steps' ` shingle roof with no required cutting of shingles. The L 1.) Locate the rafter and drill the pilot We Foot is engineered for maximum adjustability for a clean level installation 2).Prop and attach the base" 3) Set the flashing and attach_,the._L Foot r. • 1"slotted bolt connection • 1" spacers available for increased adjustability ' • Clear or Black anodized aluminum components Place order`throug•h yobr SnapNrack (both available with black flashing) distributor, which can be found at No Cutting of shingles www:snapnrock:com/contact . SnapNiuck' Patent Pending FV,, Momngng Systems ' - Flashed L Foot Kit Assembled(1"spacer sold separately) Flashed L Foot Kit Parts(1°spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions SNAPNRACK CHANNEL NUT SNAPNRACK 92 DEGREE L-FOOT,CLEAR 5/1618 FLANGE NUT 511618X SIN BOLT WTrH ,a• " -SRXr LOCK WASHER SNAPNRACK COMPOSMON FLASHING V ,L00 1 3 43 SNAPNRACK L-FOOT BASE 86 SnapNrack Flashed Foot TechnicalData Patent Pending Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 lbs Design Uplight Load 200 lbs Uplift Design Ultimate Load 1,000 lbs Uplift Warranty 10 Year material and worksmanship SnapNrack, PV Houhthg systems (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks ©2013 by SnapNrack PV Mounting System All rights reserved SERIES • UL Snap,Ntack Solar an aing. The SnapNrack line of solar mounting - solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive down costs and improve installation quality on more than 350 MW of solar installations. " ": F =: LP° : ,��:f'; r:' �-. ��: �r Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System a; is an efficient, visually appealing, hotovoltaic PV module installation system. Series 100 UL is Listed — - -- -- --- - to the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for Roof.System.111 4 Simple.-Steps: , electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration grounding hardware.The System's components provide Tool-(configure.snapnrack.com) and select an adequate bonding path which has eliminated the "Yes" for-UL 2703 Listed 1 need for grounding lugs and washers at each module, (. and bonding jumpers between splices. The UL 2703 2) Identify Site Conditions.(Array Tilt, Building.. Listing ensures that SnapNrack partners can provide Height, Roof Type, Wind and Snow'L°oads) the best in class installations in quality, safety, and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill.of Materials: • All bonding hardware is fully integrated into the1. ' components 4) Place order with your distributor. Purchase material for a single project or order in bulk • No grounding lugs required for modules for",additional savings ' • Rail splices bond rails together, no rail jumpers j required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) U • Class A Fire Rating Type 1 and 2 modules p` LISTED PV Mounting System Patent Pending 2703 Stainless Bolt with Stainless Steel SnapNrack Bonding _SnapNrack Standard Rail Split-Lock Washer Bolt with Split- Splice Insert Lock Washer SnapNrack Bonding SnapNrack Adjustable End SnapNrack Splice Clamp Top BondingBase Mid Clamp SnapNrack SnapNrack Bonding Bonding SnapNrack Stainless Adjustable End Bonding Channel Nut Clamp Bottom Channel Nut Stainless Hardware with Bolt with Split-Lock Washers Split Lock SnapNrack Bonding SnapNrack Bonding SnapNrack Bonding Washer Adjustable End Clamp Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6 AWG Copper Wire SnapNrack Ground Lug Assembly (ONE REQUIRED PER ROW OF MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave j UEC Pull Strap UEC Wedge Stainless Steel Bolt with Flat Washer SnapNrack Bonding Universal End Clamp SnapNrack Bonding � —10 Standoff Clamp � Assembly A SnapNrack-J Serrated Stainless�� �—SnapNrack SnapNrack Bonding Channel Nut Rubber Steel Flange Nut Bonding Channel Stainless Rain Collar Serrated Stainless Nut Flange Nut Steel Flange Bolt SnapNrack Stainless SnapNrack "= 92 Degree Flange Mill Finish L Foot Bolt Standoff - SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff SnapNrack SnapNrack Base(1-Hole a 4SnapNrack Metal Roof Base Shown) sh • L Foot Flashing Base Assembly L Foot Base SnapNrack Bonding SnapNrack Bonding SnapNrack Metal Roof Base with Standoff Assembly L Foot Base with Flashing Bonding L Foot SnapNrack Series 100 UL Technical Data Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum • Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs. & Certifications • Listed to UL Standard:2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship (download full details at snapnrack.com) SnapNrack- Solar Mounting Solutions (877) 732-2860 www.SnapNrack.com a Printed on recycled paper using soy based inks ©2015 by SnapNrack PV Mounting System All rights reserved Panasonic Photovoltaic Module Panasonic's unique heterojunctlon technology uses ultra-thin amorphous silicon layers.These thin dual layers reduce losses, ---' resulting in higher energy output than conventional panels. MCI Tab _ .,.. Finger .a Double-sldetl toxturetl aurfeoa I-type amorphous layer +" Thoaa amerphoue allloon layers reduces the recombination of '°'�� " yyyy,,'�q �t} Amorpheuo layor - Blnatrona to minimum level. Transparent electrode(TCO) °•�'"'.r;yq'^ uttice-type eI.tr.d.a Ultra-thin amorphous all!son layer Electrodes Advanced bifaclal cell designed for increased energy output The cell utilizes sunlight reflected back from the rear side material which captures more light and converted Into energy. Panasonic Conventional Z Tta _..Disse -," 7Beck Shest rt..... ' i Back Sheet Our competitive advantages �® ® High Efficiency at High Temperatures 25 Year Product and Performance Warranty" ® As temperature increases, HIT°continues to Industry leading 25 year product workmanship ® ® perform at high levels due to the industry leading and performance warranty is backed by a century temperature coefficient of-0.258%/°C No other old company- Panasonic Power output is module even comes close to our temperature guaranteed to 90 76% after 25 years, far greater characteristics That means more energy than other companies throughout the day. Quality and Reliability geo Higher Efficiency 19.7% Panasonic's vertical integration, 20 years of Enables higher power output and greater energy experience manufacturing HIT°and 20 internal yields. HIT° provides maximum production foryour tests beyond those mandated by current limited roof space. standards provides extreme quality assurance ®®® Low Degradation Unique water drainage HIT"N-type" cells result in extremely Low Light ?J The water drainage system give rain,water and Induced Degradation (LID) and zero Potential snow melt a place to go, reducing water stains and Induced Degradation (PID)which supports soiling on the panel Less dirt on the panel means reliability and longevity This technology reduces more sunlight getting through to generate power. annual degradation to 0 26% compare to 0 70% In conventional panels, guaranteeing more power for the long haul. HIT®Is a registered trademark of Panasonic Group ITO Panasonic Photovoltaic Module K ELECTRICAL SPECIFICATIONS PERFORMANCE WARRANTY 10a% Model 97% Rated Power(Pmaxli 330W 325W 95% Maximum Power Voltage(Vpm) 58,OV 57 6V R".a ., a" ` ax 9076% 5.70A 'AIMaximum Power Current Il ml 5.65A <�? 1 f- L Me¢Power Open Circuit Voltage(Voc 69.7V - 69.6V es% .:.}y'`, F 'e,tem:ws �• xsvear: Short Circuit Current(lscl 6 07A 6 03A 80% ",e,' • - --' - - ° '°,.fir"'''�`' �:ii;,, s; ✓' k+`' .-`at -Temperature Coefficient(Pmax) -0.25$//°C 0.258%/°C Temperature Coefficient IVocl -D 16V/°C -0 16V/0C Temperature Coefficient(lse) 3.34mA/°C 3.32mA/°C 70%0 ., s 10 is 20 25 NOCT 44.0°C 44 0°C ®Panasonic ❑conventional Z CEC PTC Rating 311.3W 306.5W Cell Efficiency 2209% 2176% DIMENSIONS — + 41 5hD531 1 38[351 20 31516 51 ModuleEfficiency� 19,7% '19,4% B' —H Watts per Ft.z 18.3W 18 OW -_ T Maximum System Voltage 600V 600V Series Fuse Rating15A 15A .._. __. _ __ ✓ 1 Warranted Tolerance I-'/+) +10%/-O%n* +10%/-0%* A A' I s" MECHANICAL SPECIFICATIONSModel ' 'VBHN330SAI 6,VB1qN325SA1 6ap Internal Bypass Diodes 4 Bypass Diodes I Module Area 18 02 Ft.'(1.67mz1 r 1 39 7[10091 Weight 40 81 Lbs (18 5kg) Dimensions LxWxH 62 6x41 5x1 4 in.'(1590x1053x35 mml W-Locations Cable Length+Male/-Female 40 2/40 2 in (1020/1020 mm) Cable Size/Type . J No.12 AWG/PV Cable Connector Type? Multi-Contact®TypeIV(MC4TM) u m 0994[25 251 o 0 Static Wind/Snow Load i 50 PSF(2400 Pal L.11112� Pallet Dimensions LxWxH 63 7x42 2x65 4 in 1 260(321 1 457[371 Quantity per Pallet/Pallet Weight 40 pcs/1719 Lbs 1780 kg] Unit inches(mm) Section A—A' Section B—B' Quantity per 40'Container 560 pcs FQuantity per 20'Container _ 240 pcs — _— DEPENDENCE ON IRRADIANCE 7.00 tsoow/ni OPERATING CONDITIONS&SAFETY RATINGS 600 — — — Model t a 506 800W/iii Operating Temperature -40°F to 185°F(-40°C to 85°C) c 400 sooW/rri L Hail Safety Impact Velocity , 1"hailstone(25mm)at 52 mph(23m/sl - -- U 300 400WIM Safety&Rating Certifications UL 1703,cUL,CEC I! 200 UL 1703 Fire Classification Type 2 200W/ni 25**Yrs Workmanship and Power Output(Linear]*** 100 Limited Warranty p p 000 NOTE.Standard Test Conditions Air mass 1 5,irradiance=1000W/m2,cell temp 25°C 0 10 20 30 40 50 60 70 80 *Maximum power at delivery For guarantee conditions,please check our guarantee document Voltage IV) **Installation need to be registered through our website www oanasonicusahitwarranty com within 60 days Reference data for model VBHN330SAl6 in 0rderto receive twenty-five(251 year Product workmanship Otherwise,Product Workmanship will be (Cell temperature 25°C) only fifteen 1151 years **1st year 97%,after 2nd year B 26%annual degradation to year 25 CAUTION I Please read the Installation manual carefully before using the products STC Cell temp 25°C,AMi 5,1000W/m7 Used electrical and electronic products must not be mixed with general household waste For proper treatment, 'Safety locking clip IPV-SSH41 is not supplied with the module recovery and recycling of old products,please take them to applicable collection points in accordance with NOTE Specifications and information above may change without notice your national legislation UTILITY METER- PLAN KEY SERVICE DISCONNECT- OF NFGy MAIN SERVICE PANEL- � s �Q \\nom G• 4r� PV-I SITE PLAN VENT PIPE- 0 A-1 PARTIAL LAYOUT INVERTER- g PANEL PHOTOVOLTAIC- A-2 ROOF ACCESS PLAN FUSED -SERVICE RATED DISCO- E-I ELECTRICAL ONE UNE AC DISCONNECT- Q �A� 0.�FfS0746 DIAGRAM SUPPLY SIDE CONNECTION— T L-1 LABELING SCHEMATIC DC COMBINER BOX— °co G-1 PHOTOS EXTERIOR LOCATION- ) FISHERENGINEERING G INN ER,P EES,P G (15)PV MODULES IST FLOOR LOCATION- o6T) P O BOX 30 OAKDALE NY II169 BASEMENT LOCATION (g) LICENSE NO 0146551631-106'441% GARAGE LOCATION-<�) SUNation I g 1 SUNATION 50LAR SYSTEMS I'll REMINGTON BLVD ROOF STRUCTURE m' RONKONKOMA NY III-9 NYSERDA RAFTER/SPACING-2" X 8" /I6" CC; (l)PV MODULES INSTALLER ACTUAL SPAN-12'-11" NUMBER CUSTOMER INFO SHEATHING-PLYWOOD GREGG RESIDENCE COLLAR TIES N/A. 'v ( 2015 YENNEGOTT DR RIDGE I4"-6° ^ 39 SOUTHOLD IM11 TYPE I LAYERS-ARCH ASPHALT I 1 PHOTOVOLTAIC �(Exr) ��s JOB NUMBER MODULE 3" POLE MOUNTED 15'FROM HOUSE �sawo DATE (4)PV MODULES 2•Iv• �rsaurm 4CCEu JOB NOTES RAIL I N/A JOB HARDWARE / QTY. RAFTER OPTIMIZER KITS 26 END CLAMPS'28 2"'X 8"' l 16"OG 122" RAIL'14 L-FEET 52 162'" RAIL'S LUGS 12'-11" SOFFIT RAIL SPLICES'I0 8"XI 00'SCREEN-3 ACTUAL SPAN FULL HOUSE ROOF PLAN MID CLAMPS 36 U-ANCHORS N/A EXTERIOR WALL ROOF SECTION(TYP) �• - SCALE' NTS. SCALE N T S FASTENER REQUIREMENTS BUILDING REVIEW NOTE NOTES TOTAL ARRAY AREA=419 SF TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE I. AN 18"WIDE CLEARING(FREE OF SOLAR WIND LOAD ASCE 10(SEE CALCULATIONS, THIS SHEET)41.5 ENCLOSED DOCUMENT FOR MINIMUM ACCEPTABLE EQUIPMENT)SHALL BE PROVIDED ALONG AT PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS LEAST ONE SIDE OF THE ROOF RIDGE ON THE PSF MAX. SPECIFIED IN THE BUILDING AND/OR RESIDENTIAL SAME SIDE AS THE SOLAR EQUIPMENT OR ON TOTAL UPLIFT =41 5 PSF X 419 SF=19,818.5 LBS CODE OF THE STATE OF NEW YORK. THIS REVIEW ANOTHER SIDE OF THE RIDGE THAT DOES NOT ADDITIONAL MATERIALS MODEL PANASONIC VBHN330SA16 DOES NOT GUARANTEE COMPLIANCE WITH THAT CODE. HAVE SOLAR EQUIPMENT ON IT IN ADDITION,AN I N/A 330WATT EA. FASTENER THAT RESPONS151UTY IS GUARANTEED UNDER THE IS"WIDE PATHWAY(FREE OF SOLAR EQUIPMENT) 62.6"L X 41.5"W X 1.38"D, 18.05 FT SEAL AND SIGNATURE OF THE NEW YORK STATE SHALL BE PROVIDED FROM AT LEAST ONE EAVE 40.81#/MODULE(2 3#/5F)01/2011 LAG SCREW SPEC 2032,8/04 (FLAT WASHERS REQUIRED TO BE USED WITH LAG LICENSED DESIGN PROFESSIONAL OF RECORD THAT OR GUTTER CONNECTING TO THAT IS'ROOF BOLTS) SEAL AND SIGNATURE HAS BEEN INTERPRETED AS AN RIDGE CLEARING, SYSTEM INFORMATION LAG BOLT WITHDRAWAL VALUE, 5/16" DIA, 266 LB/IN X 2-INCH THREAD DEPTH= ATTESTATION THAT,TO THE BEST OF THE LICENSEE'S 2 ROOF SHALL HAVE NO MORE THAN A SINGLE MODULE (26)VBHIN330SAI6 5321-5 CAP EACH BELIEF AND INFORMATION THE WORK IN DOCUMENT IS LAYER OF ROOF COVERING IN ADDITION TO THE OPTIMIZER (26)P-400 MINIMUM NUMBER OF LAG BOLTS REQUIRED=19,818.5 1-155/532 1_55/LAG BOLT=38 • ACCURATE SOLAR EQUIPMENT. INVERTER (1)5E160014-US TOTAL RAIL FEET=209-10" RAIL FT/ 38 BOLTS=5'-6" • CONFORMS WITH GOVERNING CODES APPUCA$LE 3 INSTALLATION OF SOLAR EQUIPMENT'SHALL BE DRAWN BY STRINGING 1(I xls), XII) MAXIMUM SPAN BETWEEN MOUNTING FEET BOLTS"'X'"USE 5'-4" MAX AT THE TIME OF THE SUBMISSION DAVID MEJIA RACKING SNAP'N'RAGK-SERIES 100 UL 2103 FLUSH-MOUNTED, PARALLEL TO AND NO MORE PACKAGE STANDARD • CONFORMS WITH REASONABLE STANDARDS OF THAN 6-INCHES ABOVE THE SURFACE OF THE SYSTEM RATING(DC) 8580 KW PRACTICE AND WITH VIEW TO THE SAFEGUARDING ROOF. REVISION EST PRODUCTION CAC) 8,991 KWH/YR OF LIFE, HEALTH, PROPERTY AND PUBLIC DATE DESIGNER NOTE 4 WEIGHT OF THE INSTALLED SYSTEM SHALL NOT EST PRODUCTION SOURCE SUNATION PRODUCTION CALCULATOR WELFARE IS THE RESPONS151UTY OF THE LICENSEE EXCEED MORE THAN 5-PSF FOR xxxxxx NIA NIA PHOTOVOLTAICS AND NO MORE THAN 6-PSF FOR xxxxxx NIA NIA STRUCTURAL STATEMENT RESIDENTIAL SOLAR HOT WATER SYSTEMS. 5 ANY PLUMBING VENTS ARE NOT TO BE CUT OR xxxxxx NIA NIA CLIMATIC GEOGRAPHIC DESIGN CRITERIA - TABLE 8301.20) THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT COVERED FOR SOLAR EQUIPMENT INSTALLATION xxxxxx NIA NIA THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC ANY RELOCATION OR MODIFICATION OF THE VENT WIND DESIGN SUBJECT TO DAMAGE MODULE SYSTEM INCLUDING UPLIFT I SHEAR THE REQUIRES A PLUMBING PERMIT AND INSPECTION SCALE EXISTING RAFTER SIZES I DIMENSIONS CONFORM TO N•T.S. WIND WIND ICE IRC-2015 TABLE 8802 5(1)-RAFTER SPANS SPECIAL SEISMIC CLIMATE FROST WINTER AIR MEAN GROUND SPEED TOPOGRAPHIC WIND EXPOSURE BORNE DESIGN WEATHERING LINE TERMITE DESIGN BARRIER FLOOD FREEZING ANNUAL TITLE SITE PLAN SNOW LOAD (MPH) EFFECTS CATEGORY DEBRIS ZONE UNDERLAYMENT HAZARD THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE REGION ZONE CATEGORY DEPTH TEMP REQUIRED INDEX TEMP MOUNTING BRACKETS AND HARDWARE MEET OR MINIMUM DESIGN STANDARDS FOR BUILDING AND MOD SEE EXCEED NEW YORK STATE CODE REQUIREMENTS FOR OTHER STRUCTURES OF THE ASCE 1-10,IRC 2015 20 PSF 130 B NO B 2 G 4A SEVERE 3-0" TO15 DEG NA PLANS 599 51 THE DESIGN CRITERIA OF THE TOWN AND NEW YORK STATE UCS 2011pvm I HEAVY EXAMINER OF NFA (1) UPPER WEST ROOF �P�\\°m G Ftp p 242° TRUE; 20° TILT; 4.5/12 PITCH �} CIS) MODULES n NO 074659 �FfSS 1ONP�- -721 RR.T'X8 FISHER ENGINEERING SERVICES,P C WILLIAM G FISHER,P E- P P O BOX 30 OAKDALE MY 11169 LICENSE NO 014659 1631-1864419 eP y SUNation `✓ 6r�Y SJ'a,ts,i G°cud be SUNATION SOLAR SYSTEMS Ili REMINGTON BLVD i RONKONKOMA NY II119 AI NYSERDA STAIIER INSTALLE4 / NUMBER 2"SPACING CUSTOMER INFO BETWEEN ROWS GREGG RESIDENCE PARTIAL HOUSE ROOF PLAN 2015 YENNEGOTT DR SOUTHOLD 119"11 SCALE 3/16�� = I�0" qr� / ° ° JOB NUMBER 1 11051 / DATE 2 8, 12.28.1 JOB NOTES I N/A _ GUTTER 5e'-I' FA 24'-4" RIDGE 24'-6" AI ' KYLIG 24'X 48" ' A16 3"0 PVC / ROOF AREA ADDITIONAL MATERIALS I N/A - SNAP'N'RAGK SYSTEM " LEACH L RAIL ACROSS / _ EACH ROW OF ARRAY) AI (ONLY TWO SHOWN FOR CLARITY) / / 23' GUTTER DRAWN BY DAVID MEJIA _ vvv / REVISION / DATE DESIGNER NOTE XXXXXX NIA N/A 1 X� XXXXXX NIA N/A Ag A 0 a All / XXXXX NIA N/A / / PHOTOVOLTAIC / XXXXXXI NIA I N/A U MODULE(TYP) 25'-6•' q1 // AI5SCALE (2) UPPER SOUTH HIP ROOF GUTTER F:3�1(0�� = 1 (3) UPPER EAST ROOF 152° TRUE; 20° TILT; 4.5/12 PITCH - (02° TRUE; 20° TILT; 4.5/12 IT / TITLE PARTIAL LAYOUT (4) MODULES (l) MODULES 14 APPROVED BY• i OF Al GROUND ,�P���o m �•F,s f- AGCE99 O r S acc>ss FA��FfSS I oox- V FISHER ENGINEERING SERVICES,P G WILLIAM G FISHER,P E P O BOX 36 OAKDALE KY IIlb9 LIOENeE NO 01465S 1 631-18&-4419 (15) PV MODULES SUNATION SOLAR SYSTEMS Ill REMINGTON BLVD RONKONKOMA NY II'119 NSTAI I E ���� INSTALLER m NUMBER z CUSTOMER INFO O GREGG RESIDENCE z 2015 YENNECOTT DR m SOUTHOLD 1191 I` JOB NUMBER ('l)PV MODULES 1.11051 DATE 12.28.11 NOTES <' I N/A INV ( DG AC ROOF ACCESS �FOLE EXT) ROOFACCESS MOUNTED 15' FROM HOUSEyvv GROUND AGGE55 (4)PV MODULES GROUND ACCESS FRONT OF HOUSE-FACING STREET,DRIVEWAY 83241 ACCESS AND PATHWAYS -ROOF ACCESS, PATHWAYS AND SPACING REQUIREMENTS FOR SOLAR PHOTOVOLTAIC SYSTEMS SHALL BE PROVIDED IN ACCORDANCE WITH DRAWN BY SECTIONS R324'1 1 THROUGH 8324-1 6 EXCEPTION(S} DAVID MEJA I ROOF ACCESS, PATHWAYS AND SPACING REQUIREMENTS NEED NOT BE PROVIDED WHERE AN ALTERNATIVE VENTILATION METHOD HAS BEEN PROVIDED, OR WHERE REVISION VERTICAL VENTILATION TECHNIQUES WILL NOT BE EMPLOYED DATE DESIGNER NOTE 2. DETACHED NON-HABITABLE GROUP U STRUCTURES. xxxxxx NIA N/A 832415 HIP ROOFS - PANELS, MODULES AND ARRAYS INSTALLED ON DWELLINGS WITH HIP ROOFS SHALL BE LOCATED IN A MANNER THAT PROVIDES A CLEAR ACCESS xxxxxx N/A NIA PATHWAY NOT LESS THAN 36 INCHES (914 MM)EXTENDING FROM THE ROOF ACCESS POINT TO THE RIDGE OR PEAK, ON EACH ROOF SLOPE WHERE PANELS, MODULES OR XxXx XX NIA NIA ARRAYS ARE LOCATED EXCEPTION(S} xxxxxx NIA NIA 1, ROOFS WITH SLOPES OF 2 UNITS VERTICAL AND 12 UNITS HORIZONTAL(166 PERCENT)AND LESS SCALE 2. STRUCTURES WHERE AN ACCESS ROOF FRONTS A STREET, DRIVEWAY OR OTHER AREA READILY ACCES15LE TO EMERGENCY RESPONDERS. w -T-C5 R324 I I ALLOWANCE FOR SMOKE VENTILATION OPERATIONS - PANELS AND MODULES SHALL NOT BE LOCATED LESS THAN 18 INCHES (45-1 MM)FROM A RIDGE OR PEAK TITLE ROOF ACCESS PLAN EXCEPTION(S> I WHERE AN ALTERNATIVE VENTILATION METHOD HAS BEEN PROVIDED OR WHERE VERTICAL VENTILATION METHODS WILL NOT BE EMPLOYED BETWEEN THE UPPER MOST PORTION OF THE SOLAR PHOTOVOLTAIC SYSTEM AND THE ROOF RIDGE OR PEAK. A=2 2. DETACHED GARAGES OR ACCESSORY STRUCTURES OF N �O s F oho° 07W6 FESS 1ONp�- FlSHER ENGINEERING SERVICES,P 7C WILLIAM G FISHER,PE P O BOX 30 OAKDALE NY II169 UcO sE NO 014659/631-186-4419 UTILITY SERVICE SUNATION SOLAR SYSTEMS IT REMINGTO14 BLVD RONKONKOMA NY 11119 1 2 14 15 N TALLER 435r.7 NUMBER — CUSTOMER INFO ' SOLAR EDGE SE16001-1-US INVERTER NOTE GREGG RESIDENCE OPTIMIZER UNGROUNDED WITH (TY') MODULE J-BOX INTEGRAL DC SAFETY SWITCH OO THIS MDP HAS A 200 AMP 2615 YENNEGOTT DR (TYP) I 120/240 MAX32 AMP 2400ARATED BUS WITH A 200 AMP STRING I X 32 I-PH 0A MAIN BREAKER SOUTHOLD 11911 O MAIN 200A BUS X 120%=240A JOB NUMBER PV MODULE • • 240A-200A MAIN=40A 1-11 40`1 (TYP) I / / THE MAXIMUM BACK-FEED iJ //-/?�/ CIRCUIT BREAKER SIZE'S DATE STRING OF I 40 AMP PER NEC 2011 SEC (15)PANASONIC V5HN3305AI&W/ 11� 10512(DX2)(3XB) 12.2811 (15)OP-400 CURRENT LIMITING OPTIMIZERS 2P 40A - I -2 IN•SERIES CIRCUIT• 10- II- INVERTER NOTES OGPD I N/A --- --- — DG AC 2 G INPUT OUTPUT — MAIN SERVICE PANEL STRING 2 CONDUIT AND CONDUCTOR SCHEDULE STRING OF TAG DESCRIPTION OR CONDUCTOR NUMBER OF CONDUIT CONDUIT RUN (II)PANASONIC VBHN330SAI6 W/ (II)OP-400 CURRENT LIMITING OPTIMIZERS CONDUCTOR TYPE GAUGE CONDUCTORS TYPE SIZE LENGTH IN SERIES CIRCUIT I Fv WIRE 10 4 LFMG 1 25" 10' Car_ ro 1 LFMG 1.25" 10' Y WIRE 10 4 PVC SCH. 80 1.25" 24' GC 6 1 PVC SCH. 80 1.25" 24' V WIRE 10 4 LFMG / EMT 1.25" 8' GC 6 I LFMG / EMT 1.25" 8' BUILDING 2 FHWN-2 6 3 PVC SCH. 80 1.25" 4' GROUNDING GG/CEG 6 I PVC SCH. 80 1.25" 4' ELECTRODE DRAWN BY DAVID MEDIA - SCALE N.T.S. TITLE ONE-LINE DIAGRAM E- 1