HomeMy WebLinkAbout42101-Z ��o�}1SUEF�t'�CpGy Town of Southold 1/9/2018
o P.O.Box 1179
o • 53095 Main Rd
Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 39436 Date: 1/9/2018
THIS CERTIFIES that the building SOLAR PANEL
Location of Property: 1745 Water Terrace, Southold
SCTM#: 473889 Sec/Block/Lot: 88.-6-13.13
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
10/24/2017 pursuant to which Building Permit No. 42101 dated 10/31/2017
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
roof mounted solar panel replacement on an existing one family dwelling as applied for.
The certificate is issued to Trimboli,Gregory
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 42101 12/19/2017
PLUMBERS CERTIFICATION DATED
Authorized Signature
�suFFnt,r. TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
oy._• o� SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 42101 Date: 10/31/2017
Permission is hereby granted to:
Trimboli, Gregory
1745 Water Ter
PO BOX 226
Southold, NY 11971
To: install roof-mounted solar panels on existing single-family dwelling as applied for.
At premises located at:
1745 Water Terrace, Southold
SCTM # 473889
Sec/Block/Lot# 88.-6-13.13
Pursuant to application dated 10/24/2017 and approved by the Building Inspector.
To expire on 5/2/2019.
Fees:
SOLAR PANELS $50.00
ELECTRIC $100.00
CO -ALTERATION TO DWELLING $50.00
Total: $200.00
g Inspector
Form No.6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
'765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings, property lines, streets,and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters. -
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I% lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied,the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy -New dwelling$50.00,.Additions to dwelling$50.00, Alterations to dwelling$50.00,
Swimming pool $5,0.00, Accessory building$50.00, Additions to accessory building$50.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building- $100.00
J. Copy of Certificate of Occupancy-$.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy- Residential$15.00, Commercial $15.00
Date.
,New Construction: Old or Pre--exisjtinng Building: (check one)
Location of Property; 7 VV�r V �Q V ra C-t-,
House No. Street Hamlet
Owner or Owners of Property:
Suffolk County Tax Map No 1000, Section C> 0 Block Lot 3 0 3
Subdivision Filed Map. Lot:
Permit No. Date of Permit. Applicant:
Health Dept. Approval: Underwriters Approval:
Planning Board Approval: /
Request for: Temporary Certificate Final Certificate: ✓ (check one)
Fee Submitted: $ 0
h ant Signatur
pE SOU��®�®
Town Hall Annex Telephone(631)765-1802
54375 Main Road y Fax(631)765-9502
P.O.Box 1179 @
.®l�']�.y.��q® a® roper.richertCa�town.southold.ny.us
Southold,NY 11971-0959
Cnu ,
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICIAL COMPLIANCE
SITE LOCATION
Issued To: Trimboli
Address: 1745 Water Terrace city,Southold st: New York zip: 11971
Building Permit* 42101 Section: $$ Block: 6 Lot: 13.13
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
contractor: DBA: Cal Tec Elec License No: 44095-ME
SITE DETAILS
Office Use Only
Residential X Indoor Basement Service Only
Commerical Outdoor X 1st Floor Pool
New Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
INVENTORY
Service 1 ph Heat Duplec Recpt Ceding Fixtures HID Fixtures
Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors
Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps
Transformer Appliances Dryer Recpt Emergency FixtureTime Clocks
Disconnect Switches Twist Lock Exit Fixtures TVSS
Other Equipment: Install New Photovoltaic Panels to Replace Panels in Existing System.
Notes. Size of System (6.650KW) and Original Wireing Remains the Same, Only Panels
Have Seen Replaced.
Inspector Signature: Date: December 19, 2017
0-Cert Electrical Compliance Form.xls
J A M E S J. S TOUT A R C H I T E C T & Assoc.
2 G REG L ANE E AST N0RTHP ORT N. Y. 831 - 8 58 3388
Post Installation Letter
January 8, 2018
RE: Trimboli Residence
1745 Water Terrace
Southold, NY 11971
To Whom It May Concern:
This letter is to confirm that as of this date January 8th, I, James J Stout, NYS license 021633
have personally inspected the placement and installation of the roof top solar panels at the
above listed address. All of the solar panels have been installed as per manufacturer's
guidelines and specifications. The racking system design and installation complies with the
2017 NYSRC and 2017 NYSUCS building code and all related provisions. The installation of
panels was done as per plan.
James J. Stout
Architect
AR
C' J STS
0216 33
OF �E� D f�C[E�'V[E
D
JAN 9 2018
BUMDDIDTG DE".
TOWN OF S®MOLD
FIELD INSPECTION REPORT DATE COMMENTS 41
FOUNDATION (1ST) �3
------------------------------------
® ct
FOUNDATION (2ND)
z
cn
O
d®4 6
ROUGH FRAMING& y "
PLUMBING
INSULATION PER N.Y. '
STATE ENERGY CODE
FINAL
ADDITIONAL COMMENTS
rn
IR
1. y
z
d
TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following,before applying?
TOWN HALL Board of Health
-SOUTHOLD,NY 11971 4 sets of Building Plans
TEL: (631) 765-1802 Planning Board approval
FAX: (631) 765-9502 Survey
SoutholdTown.NorthFork.net PERMIT NO. � Check
Septic Form
N.Y.S.D.E.C.
Trustees
C.O.Application
Flood Permit
Examined L- ,20 Single&Separate
Storm-Water Assessment Form
^� Contact:
Approved J ,20 Mail to:
Disapproved a/c
Phone:
Expiration ,20
® ector
D
OCT 2 4 2017 PLICATION FOR BUILDING PERMIT
Date � , 20 1"?BUILDING DEQ'
TOWN OF SOUTHOLD INSTRUCTIONS
a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans,accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas,and waterways.
c. The work covered by this application may not be commenced before issuance of Building Peimit.
d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an
addition six months.Thereafter,a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws, Ordinances or
Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The
applicant agrees to comply with all applicable laws,-ordinances, building code, housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections.
(Signat of a scant or name, if a corporation)
(Mailing address of applicant
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder
Name of owner of premises
(As on,the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No. L((4 01,5.4
Plumbers License No.
-Electricians License No. [(0
Other Trade's License No.
1. Location olend on which proposed work will be done:
J"Ie'd /erroe of S16 MI —W W
House Number Street 1' 'Hamlet
� b
County Tax Map No. 1000 Section Block �� Lot
Subdivision Filed Map No. Lot
2. State existing use and occupancy of premises and i<nten ed usppd oc upancy of per posed construction:
a. Existing use and occupancy ( , '1 �
b. Intended use and occupancy /1("
3. Nature of work(check which applicable):New Building Addition Alteration
Repair Removal Demolition Other Work
(Description)
4. Estimated Cost Fee
(To be paid on filing this application)
5. If dwelling,number of dwelling units I Number of dwelling units on each floor
If garage, number of cars
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. Dimensions of existing structures, if any: Front Rear Depth
Height Number of Stories
Dimension_ s of same structure with alterations or additions: Front 4 Rear
Depth Height Number of:Stories
�ss,L i is _',",, :-. r S s
8. Dimensions of entire new construction: Front Rear Depth
Height Number of Stories
9. Size of lot: Front Rear Depth `T - "
10. Date of Purchase Name of Former Owner
11. Zone or use district in which premises are situated
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO
13. Will lot be re-graded? YES NO '`Will excess fill be removed from premises? YES NO
14.Names of Owner of remise 1 Uddress W4�Au V--(-e-
(j&Clf Phone No.
Name of Architectic QS Addres 6Yz LPN Phone No --9I�!K
Name of Contractor Address !S G- one No.- 91-�jZZ-2>S�
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? 'AYES NO
* IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS_ MAY BE QUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey,to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES NO
* IF YES, PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUN
being duly sworn,deposes and says that(s)he is the applicant
amf indiv' u igning contract)a ove named,
( is the C G�
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners,and is duly authorized to perforin or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be
performed in the manner set forth in the application filed therewith.
Sworn t�o� efore me thi -
day of 20— I.EEid-SHARMAN
Notary Public,State of Now Y rk
Registration No.01SH6=1 7'r)""I
Queiiafa®d in Sugoiic
Notary Public My commission Expires Nov 16,201 ' � Signa ire A cant
°$u � co�]KNIWA�T)ER
Scott A. Russell �T
�� ��
SUPERVISOR MANAGIENDENT
SOUTHOLD TOWN HALL-P.O.Box 1179
53095 Main Road-SOUTHOLD,NEW YORK 119T1 �sTolman of Southold
r�
CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET
( TO BE COMPLETED BY THE APPLICANT )
DOES THIS PROJECT INVOLVE ANY OF THE FOLLOWING:
Yes No (CHECK ALL THAT APPLY)
es A. Clearing, grubbing, grading or stripping of land which affects more
than 5,000 square feet of ground surface.
_ ❑ B. Excavation or f illing involving more than 200 cubic yards of material
within any parcel or any contiguous area.
❑10C. Site preparation on slopes which exceed 10 feet vertical rise to
100 feet of horizontal distance.
E]U,6 Site preparation within 100 feet of wetlands, beach, bluff or coastal
Elderosion hazard area.
E. Site preparation within the one-hundred-year floodplain as depicted
on--I~'-IRM-Map--of--any watercourse:- -
Eli Installation of new or resurfaced impervious surfaces of 1,000 square
feet or more, unless prior approval of a Stormwater Management
Control Plan was received by the Town and the proposal includes
in-kind replacement of impervious surfaces.
If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name,
Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project.
If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management tontrol Plan-
and a completed Check List Form to the Building Department with your Building Permit Application.
APPLICANT: ( roperty Owner,Design Professional,Agent,Contractor,Other) S.C.T.M. = 1 000 Datc
Duo tct
�i4cc
2 '7NAME �0 /Je% 1Section Lot
-"" FOR BL-ILDINGA DEP: }r'rliEivT USE i)�'LY
Contact information
ranee w:,.e.! ��
Reviewed By: ��
- - — — — — — — — —-- - — — — — — —
Date: `���-`C'��
Property Address/Location of Construction Work: - - — — — — — — — — — — — — — — —
® Approved for processing Building Permit.
Stormwater Management Control Plan Not Required
— — — — — — — — — — — — — — — — —
® Stormwater Management Control Plan ro Required.
(Forward to Engineering Department for Review)
FORM # SMCP-TOS MAY 2014
�.
Toda�,
g
Y -
— 1
" � k
yt �
v.
f
F
y
1:
�i
rt;':. Iia•
lo�Jer
`1o�\ ny .�l1I-kve
ple,ak an, Gsi ljqq�
-7
'1
rn
a
C �
C, �
� o
Town Hall Annex Telephone(631)765-1802
54375 Main Road Fax(631)765-9502
co _Ita
P.O.Box 1179 G ® Q
Southold,NY 11971-0959 'Q
lyC4UNTY,��
December 27, 2017
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
James Stout
2 Greg Lane
East Northport NY 11731
Re: Trimboli, 1745 Water Terrace, Southold
TO WHOM IT MAY CONCERN:
The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy:
NOTE: Post Installation Certification required stating panels were installed per NYS Building Code
Application for Certificate of Occupancy. (Enclosed)
Electrical Underwriters Certificate.
A fee of$50.00.
Final Health Department Approval.
Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84)
Trustees Certificate of Compliance. (Town Trustees#765-1892)
Final Planning Board Approval. (Planning#765-1938)
Final Fire Inspection from Fire Marshall.
Final Landmark Preservation approval.
Final inspection by Building Dept.
Final Storm Water Runoff Approval from Town Engineer
BUILDING PERMIT — 42101 — Solar Panels
LOT AREA- 30,000 sq. ft.
i2ro - -o up
'OPEN SPACE'
N 23'49'1O'E 150.00'
Z
c
0
r4
3o.
wOd N
dwk
37. 27.
2& .FR
poroft
Y I
z7.o- I
3
30.3• 3r3ks I o
I L= 1
183 c"•:
r;
S 2X49'1O"W 150.00'
WATER
lERRACJ{
�ifa5 A �_ •-•
NOTE CESSPOOL, SEPTIC TANK of WATER 3N �
SUMM LOCATIONS BY OTHERS.
2-5-2003 REVISED SWMARY W kSURBaKFS
1-16-2003 FINAL SURVEY
'M°MOM 4F Mff Or=0 A1°°a°'~"a 9-17-2002 LOCATED FOUNDATIONr0r aoaM Ns acres` .8-7-2002 REVISED DWELLING
=ZUAWAWvvs aTwaa pi0�f AAa*M� rl�*c A1R�MD 7o M
sMy 63
gum
J08 No. 00- 5 FILE No. ANGEI. SHORES
'NCM N6al Mu to MA ca ACr mm awwoomn
F ANd1 L
W MINNA av 0 AAMC m*M MLY A•PMMA M m Timor OT N 137 GREGORY TRIMBOLI
m or*A$ft vasa sm Mm uO. LOT /0 R L
MAP OOF EL SHORES
VAWAV as MMM M WM AML AA QU TO MS FM*MA WM M
now■MMAM Na)as m mvw To va ME asamm Mo MNML SITUATED AT eAYVIf_W
AMM A4 tlDma MM NM=CAw mom AA D M Kali®r Im '
imM=MmRwwa,m An nor>Iomwa va -rtA°'a.mmumw TOWN OF SOMHOLD — SUFFOLK COUNTY N.Y.
cma or*maSam rr aor n Tx um A1AI@fin Mita Man ox SCALE 1' _+ 40' DATE 7-19-1999
i•aAilaa AIAL>Ml�t D>�A�A*!A�t Q1T. '
FILED MAP Na. 9729 DATE 8-23-19915
CERTIFIED ONLY TO: TAX MAP No.(REF 0"1000-88-6-13.13 DISK 500
GREGORY lRAMU
SUNRISE ABS7RACr CORP' HAROLD F. TRANCHON JR. P.C.
BNY MORi`GAGE COMPANY LLC LAND SURVEYOR
IBBB WADING RNER—MANOR RD.WADING RIVER,
NEW YORK, 11792
I.J FIAROLD F.TRANCFON JR. PEW LIC No. 2152 631-928-4695
—E
YORK Workers' CERTIFICATE OF INSURANCE COVERAGE
STATE Compensation
Board SUNDER THE NYS DISAWLITY BENEFITS LAWi3
PART 1. To be completed by Disability Benefits Carrier or Licensed Insurance Agent of that Carrier
1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured
(631)422-3500
SUNSHINE PLUS SgLAR CORP 1 c.NYS Unemployment Insurance Employer Registration Number of
15 4TH AVE Insured
SMITHTOWN,NY 11787-4519
Work Location of Insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security
certain locations in New York State,i.e.,a Wrap-Up Policy) Number
471-62-0611
2.Name and Address of Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier
(Entity Being Listed as the Certificate Holder) New York State Insurance Fund(NYSIF)
3b. Policy Number of Entity Listed in Box"1 a"
TOWN OF SOUTHOLD BUILDING DEPARTMENT
54375 ROUTE 25 DBL 6027 50-3
PO BOX 11971 3c.Policy effective period
SOUTHOLD,NY 11971 y
01/07/2011 to 01/07/2018
4.Policy covers-
A.All of the employer's employees eligible under the New York Disability Benefits Law
B.Only the following class or classes of employer's employees:
Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named
insured has NYS Disability Benefits insurance coverage as described above.
Date Signed 10/10/2017 By ;' - Joseph J.Masi
(Signature of insurance carrier's authorized representative of NYS Licensed Insurance Agent of that insurance carrier)
Telephone Number (866)697-4332 Tide Director of NYSIF Disability Benefits Insurance
IMPORTANT: If Box`4a"is checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that
carrier,this certificate is COMPLETE.Mad it directly to the certificate holder.
If Box"4b"is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the Disability Benefits Law.It must be mailed
for completion to the Workers'Compensation Board,DB Plans Acceptance Unit,328 State Street,Schenectady, NY 12305
PART 2.To be completed by the NYS Workers' Compensation Board (Only if Box"41b"of Part 1 has been checked)
State of New York
Workers' Compensation Board)
According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS
Disability Benefits Law with respect to all of his/her employees.
Date Signed By_
Signature of NYS Workers'Compensation Board Employee)
Telephone Number Title
Please Note: Only insurance carriers licensed to write NYS disability benefits insurance policies and NYS licensed insurance agents of
those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form.
DB-120.1 (9-15) Certificate Number 455559
New York State Insurance Fund
Workers'Compensation &Disability Benefits Specialists Since 1914
8 CORPORATE CENTER DR,3RD FLR,MELVILLE,NEW YORK 11747-3129
CERTIFICATE OF WORKERS' COMPENSATION INSURANCE
i�eA 1U
AAAAAA 471620611
SUNSHINE PLUS SOLAR CORP y
15 4TH AVE y
SMITHTOWN NY 11787 }91
�{
6f11
Scan to Validate
POLICYHOLDER CERTIFICATE FOLDER TRIMBOLI
SUNSHINE PLUS SOLAR CORP TOWN OF SOUTHOLD
15 4TH;AVE 54375 RT 25
SMITH`fOWN NY 11787 SOUTHOLD NY 11971
POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE
12112'1890-4 893356 12/08/2016 TO 12/08/2017 10/16/2017
e
THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE
FUND UNDER POLICY NO. 2121890-4, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR
WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL
OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT 1'0 OPERATIONS
OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY.
IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS,
OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW
YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS.
THIS POL1ICY DOES NOT COVER CLAIMS OR SUITS THAT ARISE FROM BODILY INJURY SUFFERED BY THE OFFICERS OF THE
INSURED CORPORATION.
PRESIDENT
KEVIN J CREAMER
OF A ONE PERSON CORPORATION
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE
COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER
THE COVERAGE AFFORDED BY THE POLICY.
NEW YORK STATE INSURANCE FUND
jd et-e—
DIRECTOR,INSURANCE FUND UNDERWRITING
VALIDATION NUMBER: 1035030440
U-26.3
I _ SUFFOLK COUNTY DEPT OF LABOR,
t ,t LICENSING 8 CONSUMER AFFAIRS
MASTER
»..�
ELECTRICIAN
MICHAEL LEONARCI
This certlfes that the 6USNEGb NAC
CALTECH ELECTRIC INC
bearer is duly
licensed by the Ll—N~ Dye t.-I
County of Suffolk 03/08/2006
//// /�}}Jy // 39161-ME
GXPWnw bats 031'01/2018
SUFFOLK COUNTY DEPT OF LABOR,
LICENSING&CONSUMER AFFAIRS
f >>T ,•:e. HOME_IMPROVEMENT
CONTRACTOR
`
LICENSE
'r =Y
KEVIN J CREAMER
This certifies that the 6"S"Es9'"` '
bearer is duly SUNSHINE PLUS SOLAR CORP
licensed by the
County of Suffolk `"�"'w"'" oa, a�•e
44095-H otio»2oos
EXPRATIC"OATS 02JO 1/2018
J A M E S J. S TOUT A R C H I T E C T & Assoc .
2 GREG LANE E AST NoRTHPORTN. Y. 631 - 8 58 9388
Letter of Certification
October 19, 2017
RE: Trimboli Residence
1746 Water Terrace
Southold, NY 11971
To Whom It May Concern:
I, James J. Stout, registered architect NYS license number 021633 would like to
submit the following. I have inspected and analyzed the roof structure at the above-
mentioned address and have determined the structure and the panel attachment to
be adequate to support the new additional load imposed by the proposed solar hot
water system and complies with the 130-mph wind design load as 2016 New York
State Uniform Code (2016 NYSUC), 2016 New York State Residential Code (2016
NYSRC)= (2015 International Residential Code (2015 IRC) (2nd Printing) and 2016
New York State Uniform Code Supplement(2016 NYSUCS) and the 2014 National
Electric Code NFPA 7012014 National Electric Code.
The existing 2"x 8" roof rafters 16"oc will provide the required support.
Thank you for your understanding in this matter.
James J. Stout
�kED.A/30
O T
441 G
2 633
T
N��
www.hhi-green.com/solar/en
U n H ®: /
a mado, U e
Hyundai Heavy Industries was founded in 1972 and is a Fortune 500 company.The company employs more than 48,000 people,and has a global
leading 7 business divisions with sales of 51.3 Billion USD in 2013.As one of our core businesses of the company,Hyundai Heavy Industries is
committed to develop and invest heavily in the field of renewable energy.
Hyundai Solar Is the largest and the longest standing PV cell and module manufacturer in South Korea.We have 600 MW of module production
capacity and provide high-quality solar PV products to more than 3,000 customers worldwide.We strive to achieve one of the most efficient PV
modules by establishing an R&D laboratory and investing more than 20 Million USD on innovative technologies.
PERL Multi-crystalline Type
HiS-M265RG 1 HiS-M270RG I HiS-M275RG
-S��I�S Mono-crystalline Type
�°
HiS-S280RG I HiS-S285RG I HIS-S290RG
Mechanical Characteristics X Several models are under certification process
998 mm(39.29'1(W)x 1,640 mm(64.57")(L)x 35 mm(1.38")(H)
Approx.18 7 kg(41.2 lbs)
60 cells in series(6 x10 matrix)with PERL technology(Hyundai cell,Made in Korea)
4 mm'(12AWG)cables with polarized weatherproof connectors,
IEC certified(UL listed),Length 1.0 m(39A'l
IP67,weatherproof,IEC certified(UL listed)
3 bypass diodes to prevent power decrease by partial shade
� �• Front:Anti-reflective coating low-iron tempered glass,3.2 mm(0126")
Encapsulant:EVA Back Sheet:Weatherproof film
�r1 Clear anodized aluminum alloy type 6063(Black)
High Quality
•IEC 61215(Ed 2)and IEC 61730 by VDE �' I
•UL listed UL 1703),Type 1 for Class A Fire Rating
•Output power tolerance+3/-0%
•ISO 9001:2000,ISO 14001:2004 and ISO 50001:2011 Certified * I '�
OHSAS 18001.2007 CertifiedMEN
•Advanced Mechanical Test(8,000 Pa)Passed(IEC)
/Mechanical Load Test(40 Ibs/ft')Passed(UL) c
Ammonia Corrosion Resistance Test Passed
•IEC 61701 (Salt Mist Corrosion Test)Passed
Limited Warranty ; • ;:, : . I ��, ' •,
•1 st year:97
•After 2nd year:0.7%annual degradation
80 2%for 25 years
►Please refer to the Hyundai Limited Warranty for more details.
X Important Notice on Warranty
The warranties apply only to the PV modules with Hyundai Heavy Industries Co,Ltd's
logo(shown below)and product serial number on it
GVE C E c �6 us k Pv c�wo ®yr;r2 Le gra\• ;a
!lS,EU `a.,�>Y _rpt HEAV 'ONDUSTl IES
Electrical Characteristics
Multi-crystalline Type
Nominal output(Pmpp) W 265 270 l 275
Voltage at Pmax(Vmpp) V 31.3 Al 4 31.5
Current at Pmax Pmpp) A 8.s 86 8,7
Open circuit voltage(Voc) V 37.9 38.0 382
Short circuit current(Isc) A 9.1 9°2 ___9_3_
Output tolerance % +3/-0
No of cells&connections I PCs 60 in series
Cell type 6"Multi-crystalline silicon with PERL technology(Hyundai cell,Made in Korea) r
_ _ -90
..
Module efficiency % 16.2 165 16.8
Temperature coefficientofPmpp %/K 041 -041 -041
Temperature coefficient of Voc %/K -032 -032 -032
Temperature coefficientoflsc %/K 0.039 0,039 I 0.039
X All data at STC(Standard Test Conditions)Above data may be changed without prior notice
Mono-crystalline Type
Nominal output(Pmpp) W 280 285 290
Voltage at Pmax(Vmpp) V 31 7 318 32.0
Current at Pmax(Impp) A 88 89 9.1
Open circuit voltage(Voc) V 38.538.7 388
Short circuit cul rent(Isc) A -- - 9.4 95 97
Output tolerance
No.of cells&connections PCs 60 in series
Cell type 6"Mono-crystalline silicon with PERL technology(Hyundai cell,Made in Korea)
Module efficiency % 17.1 17.4 17.7
Temperature coefficient of Pmpp I %/K -0.420 42 0.42
Temperature coefficient of Voc %/K -0.30 d -0.30 0.30
Temperature coefficient of Isc %/K -0 047 0.047 0 047
XAll data at STC(Standard Test Conditions)Above data maybe changed without prior notice
Module Diagram (unit mm,mch) IN Curves
C°nent[A]
m
° —SC
o e 1000W/mt —25'C
7
\ — s —45-C
41(07{11 751037 5 65-C8 HOLES
0 (a) DETAILA
1,000mm 1,000mm
ffTHRUD93n 4mmICA&E& 4m CAM& t
CONNEClOA CONNECTOR �' 0
$ o s to is 7° 75 50 35 40 45
NrtentW VcltegeM
GROI➢JDMAW DETAILS to
1,000W7m7
4x04.2 18(071')
h
GROUNDHOLE 60841 11(0.43 6 —BOO5YAn7
EE: -600W/m
I�I
954(37561 �' t—� 5 —400W/.'L.JIII
4 --200WAn'
C
A 7
998(3.291 C 753(9%1 30 11 78 00 t
SECTION C{
00 5 t° 15 fi u 30 3S W l5 50
VohzgeM
Installation Safety Guide -
•Only qualified personnel should install or perform maintenance. -40-a5°C
•Be aware of dangerous high DC voltage. DC 1,000 V(IEC)
' _� DC 600 V(UL)
•Do not damage or scratch the rear surface of the module. °�` ='-'•'°�- � -
•Do not handle or install modules when they are wet. 4.`7�1 �Og 15A
[Printed Date December20153
Sales&Marketing' eGn°YvMr Hyundai Bldg,7S,Yul ok-ro,Jon no- u Seoul 03058,KoreaRcionoS fied U
Nnal
FSC
Tel +82-2-746-4671,7635,BSS6 Fax•+82-2-746-7675 HEAVY INDUSTRIES
® ® ee
C57 xantrax
• x - x i Gr.IT Sure tmerc, - >Y
Xantrex GT Series Grid Tie Solar Inverters
Xantrex photovoltaic string inverters offer high efficiency,clean aesthetics,high reliability as well as lower
installed cost through time-saving installation and included features.The result is a high-performance inverter
that makes utility-interactive Installations easier and more cost effective.
Technology
0 Proven high-frequency design in a compact enclosure
I, Integrated DC/AC disconnect that is NEC compliant to eliminate the need for external DC(PV),and in some w ut s PHOTOVOLTAIC
jurisdictions,AC disconnects c`1 9POWER INVERTER
csAtor bol
I, Large heat sink offers extraordinary heat dispersion without the need for a cooling fan
I> Backlit,two-line,16-character liquid crystal display(LCD)provides instantaneous power,daily and lifetime
energy production,photovoltaic array voltage and current,utility voltage and frequency,time online"selling"
today,fault messages,and installer customized screens
D Bright LED indicators provide system status at-a-glance
D LCD vibration sensor allows the tap of a finger to tum backlight on and to cycle through display screens
D Integrated RS232 and XanbusTm R145 communication ports
I> Free PC software for remote monitoring and system troubleshooting available online
Installation
I> Flexible module selection and sizing due to wide PV input MPPT tracking voltage range
I> Lightweight and versatile mounting bracket simplifies installation
Modular design allows inverters to be mounted side-by-side,using each wiring box as a wiring raceway Xantrex Technology Inc.
Easy access DC(photovoltaic)and AC(utility)terminal block simplifies wiring Customer Servicefrechnical support
P Integrated,lockable AC/DC disconnect saves installation time and balance of system component cost customerservice@xantrex.com
p Rugged NEMA 313 inverter enclosure allows reliable outdoor and indoor installations Toll free:1-800-670-0707
Performance
D Best-in-class efficiency to maximize investment of solar system
� Accurate MPPT tracking ensures maximum energy harvest under any condition
p Excellent thermal performance
® FCC Part B compliance means less potential interference with communication,radio,and consumer electronics
Serviceability
D Five-year standard warranty(an additional five-year extended warranty is available)
P Sealed inverter enclosure can be separated from the wiring box allowing DC/AC connections to remain intact in
the unlikely event the inverter needs to be serviced
www.xantrex.com
0 2006 Xantrea Technology Inc M rights reserved Xantrac is a registered trademark of Xantrex Intemaaonal.Printed to Canada
This document is printed on acid free,
10%post-consumer,elemental chlorine
free Productolith paper stock.
cA�
Xantrex GT Series Grid Tie Solar Inverters
Electrical Specifications
Models GT2.5-NA-DS-240 GT3.O-NA-DS-240 GT3.3-NA-DS-240 GT3.8-NA-DS-240 GTS.O-NA-DS-240
GT3.3-NA-DS 208
Maximum AC power output 2500 W 3000 W 3300 W 3800 W 5000 W
AC output voltage(nominal) 240 Vac 240 Vac 240 Vac 240 Vac 240 Vac
208 Vac
AC output voltage range 211-264 Vac 211-264 Vac 211-264 Vac 211-264 Vac 211-264 Vac
183-228 Vac
AC frequency(nominal) 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz
AC frequency range 59.3-60.5 Hz 59.3-60.5 Hz 59.3-60.5 Hz 59.3-60,5 Hz 59.3.60,5 Hz
Maximum continuous output current 11,8A 14.2 A 15.6A 16A 23A
18A
Current THD <3% <5% <3% <3% <2%
Power factor >0.9 >0.9 >0.9 >0.9 >0.9
DC input voltage range 195-600 Vdc 195-600 Vdc 195-600 Vdc 195-600 Vdc 235-600 Vdc
Peak power tracking voltage range 195-550 Vdc 195-550 Vdc 195-550 Vdc 195-550 Vdc 235-550 Vdc
Peak inverter efficiency 94.8% 94.6% 95.3% 95.7% 96.5%
94.7%
CEC efficiency 94.0% 94.5% 94.5% 950% 95.5%
94.0%
Night-time power consumption 1 W 1 W 1 W 1 W 1 W
Output over-current protection 15A 20A 20A 20A 30A
25A
Mechanical Specifications
Operating temperature range .131F to+149°F (-25°C to+65°C)
Enclosure type NEMA 311(outdoor rated)
Unit weight 49.0 lbs(22.2 kg)to 58.OIb(25.8 kg)
Shipping weight 57.0 lbs(25.9 kg)to 65.Olb(27.2 kg)
Shipping dimensions(H x W x D) 34.1 x 20.4 x 10.3"(866 x 518 x 262 mm)
Inverter dimensions(H x W x D) 28.5 x 15.9 x 5.7"(755 x 403 x 146 mm)
Mounting Wall mount(mounting bracket Included)
Features - - - - - - - - - - - - - - - -- - - --
PV/Utility disconnect Eliminates need for external PV(DC)disconnect Complies with NEC requirements.
Cooling Convection cooled,fan not required
Display Backlit,two-line,16-character liquid crystal display provides instantaneous power,dally and lifetime energy production,
PV array voltage and current,utility voltage and frequency,time online"selling"today,
fault messages,and installer customizable screens.
Communications One RS 232 and two XanbuSTM RJ45 ports
Wiring box PV,utility,ground,and communications connections.The inverter can be separated from the wiring box.
Warranty 5-year standard(an additional 5-year extended warranty is available).
Part number(negative ground) 864-0108 864-0002 864-0107 864.0119 864.0118
864-0111
Part number(positive ground) 864-0112 NIA 864-0114 N/A NIA
0 2006 xantrex Technology Inc All nghis reserved,xantrex is a registered trademark of Xantrex intemahonal Pnnted m Canada
a
# SOLECTRIA
. F RENEWABLES
PIA MWO
Vo MWO
,j W
Pm (mo'@
F5V4 _ z -
y
OW
i
iir "
.tiye
!(I�GilU U1.�J
O amu-E CCSCi AWC( aorm�
Q Elk,flrn ��);±flrn?�,
U S5 Fu - Path a i
o 200.{U�/)'G�cc'5sC}WK��
. f
a ffbio -46C. .t o(tkal apftw 4 I
o LXfex vqr3 o a
oc7fnKe orld 1°",l_�i(�c`1Glifi'/
c @fifL+Qi�cooiVC�1 prxWflL�Cnali�l�/
STMNG INVERTERS
O M-00)4._w-lu n flroan
At 96%CEC efficiency,the Solectria Renewables string inverter series,ranging from
3.0 kW to 7.5 l(W,is the most efficient transformer isolated string inverter on the
market.The PVI 3000S-PVI 7500 series of inverters consist of five power ratings
to optimally match your grid-tied PV system,and boasts fully-integrated DC and
AC disconnects,an LCD,and a 3,4,or 5 fused string inputs all contained within a
detachable wiring box.The wiring box allows for a clean,simple,and safe installation
with easy serviceability.The integrated panel assembly comes with 1-to 2 pre-wired
inverters mounted on an industrial grade aluminum panel with kWh meter and optional
`plEnT�
AC visible-blade disconnect or circuit breakers on a two-inverter panel assembly.
cTOUSt
4,9TE
w
' mit ahl
O Roma
�k 3d )9'JJJ'L��r,,,�f��((���7..'M1M1I��� � I(��I`'f1 ,��jj�(J���� 0' D @09[c U•:Oill1�nEJ U`.ER Y dad"f%' t''�
p
N
SPEOFIcAm'Ns PV! 00'O000090S1 A • 00 �� O
O
• u:�P tf+�� - .• __•.4 - _:.}z Gyp."`. - ` .-^:{,`•; - - _- - .�ti. ✓.ea•}-4"''c - ira:_�. 'f �p7 u
13' - - - ,,may;€ - x'�,.., _ ir. '+x,.
p
Absolute Maximum Input Voltage 600VDC-
MPPTInputVoltage'Range 200-550VDC230-50OVDC N
Start Up Voltage 210V 230V s
- - m
Maximum Operating Input Current 16A 21 A 25A 35A 35A :v
' 3 D ";j' -�. _ - - ii��'=ym-r'.,,, - �..» - `.�.+ 3,>'=F'ti���� - -•!:✓ -++�4� ..>N, G�r{, d ,
s,f':y�• �e:
Nominal output Voltage 208 or 240 VAC 208,240 or 277 C
AC Voltage Range(Standard) -12%/+10% o
' { 208 VAC 2800 W 3500 W 4400 W 6500 W 7500 W d
Continuous Output Power 240 VAC 3000 W 4000W 5000 W 6500 W 7500 W s
"i 277 VAC -- 6500 W 7500 W 3
208VAC 13.5A 16.8A 21.15A 31.3A 36.1A p'
Continuous Output Current 240 VAC^ 13.5 A 16.8 A 21.15 A 27.1 A 31.3 A
277 VAC 23.5 A 27.1 A
Maximum Backfeed Current 0 A '
- -
c ..
Nominal Output Frequency 60 Hz =
- - . _ - - __ ___ _ _---__ _ __ __ _ - -_, _ - _ _ _ __ _ -,_ __ - -,___ - - -_ " <
Output Frequency Range 59.3-60.5 Hz t j,
Power Factor Unity,>0.99 ;
Total Harmonic Distortion(THD) (3%
y m 4^ Y„ ce r is a 5'e a'o .f s { ..._ �ra< s R•:. ,,,,
208 VAC 96.4% 96.5% 96,4% 1 96,0% 96.2% ,'2, ^
Peak Efficiency 240 VAC 96.7% 96.7% 96.7% 96.3% 96.5%
o
277 VAC 96.7% 96.7%
,
208 VAC 95.5% 95.5% 96.0% 95.0%
CEC Efficiency 240 VAC 96 0% _ 96.0% 96.0% - -96.0% ^
277 VAC 96.0%
Tare Loss 0.5 W
Fused String Inputs 3 4 4 5 5
-�ri "'n'"`�%g�' "•_ - "¢,` C,�:•r„ �-a�� `�`•i'r_ ,K - b.- _.� ,Sa'._r; -�,.f{, >,,.
,A-'a- °'•�::';;'r�Y`-�z';�`•;�+� v.+ - �,.s -�.'_.'2,_..��•.. - Via: ,
Ambient Temperature Range(full power) 131Fto+1221F(-250Cto+500C) ;
Storage Temperature Range 13°Fto+1310F(-25°Cto+550C) -13°Fto+1490F(-250C to+65°C)
Relative Humidity(non-condensing) , 5.95%
',�� - - - N' .,_"--"'-;r .,i^ - -- - - �'�'T»+�y -ham-�X ,.• _ - �
iA. ..,N - '.Y.,:��Y+ u.,. „s,i -,h. .��,. _ `;`,'a'^�,'''.. .',r4�...i'.`.,•`,i_iu+_� _ ,x ��.p: ^;k'`r , `,y't�,rw,k:
I, ,�,' -"'t" � - �-+w-3�:. :y; a. - ,i,,, i•'���' .:7i,r. Niro.%.., .r i�:.,•�'-,z',f
Optional SolrenView Web-based Monitoring External ;'
Optional Revenue Grade Monitoring External
External Communication Interface RS485
- "�8^��yY;,^,-..'+.-�'^, ^,,�,,•-.';,,, .2 '` - ,ti.k ><N�.j; ke,_- . .'-"J- „'.n-'.;P,g^..,^e.°v _ - :n„ ;'"!,' ''t't`,*�v.^,"`�rt".'µre`.y''v `t� °
�RAAP. :. ";�9 a`r„ .r; _ �{r W v.N,,t - - _ �t.f`"�•` _ ,'].,Y `� i y<3•
+�°•�r.�^.^'�. - - '3a:. - -`+._'u.`+6:.:'- _ ���'ki.w �.>vA,'i3i:ss_1
Safety Listings&Certifications UL 1741/IEEE 1547,IEEE 1547.1,CSA C22.2#107.1,FCC part 15 8
Testing Agency ETL _
- - .:.F�" zz
_ :'lt��_ �• - .,.h,` _ ..�_� hey_.S. - - '(�:J� k��Yi<i[ - - _ ,
Standard 10 year
x' l;•, ',?¢,�7 `-r:,•;;,,;wt,':x' .`s _ _ _ _ .•a. ,;s' .;�„^
AC/DC Disconnects Standard,
fully-integrated(internal)
Dimensions(H x W x D) 28.8 in.x 17.9 in.x 6.9 in. 28.8 in.x 17.9 in.x 7 in. 28.8 in.x 17.3 in.x 8.2 in.
(732 mm x 454 mm x 175 mm) (732 mm x 454 mm x 187 mm) (732 mm x 438 mm x 208 mm)
Weight 48.8 lbs(22.2'kg) 59.8,lbs(27.2 kg) 88.9 lbs(40.4 kg)
Enclosure Rating Type 311
Enclosure Finish Painted aluminum
SOL
ECTRIA•
B E N E Wf A B L E S www.solectria:cort5° I;° inverters@solectria.com - 97`8.683.9700 °�
V ' f - o Z • `
Cc
SITE MAP GENERAL NOTES JOB NO
2017—S02025
1. SOLAR PANELS WILL BE ( 24 ) HYUNDAI 280 WATT PV MODULES, WITH
( 1 ) XANTREX GT 3.0 ( 1 ) XANTREX GT 3.8 AND ( 1 ) SOLECTRIA 3000
STRING INVERTERS
2. PROVIDE A.C. DISCONNECT: CUTLER HAMMER DG221VRB-30A GENERAL LL
DUTY SAFETY SWITCH, NON FUSIBLE, 240VAC, NEMA 3R. z O
3. THE AC DISCONNECT WILL BE LABELED AS "UTILITY DISCONNECT AND z O r-
PHOTOVOLTAIC SYSTEM LOCK-OUT" LOCATED WITHIN VIEW OF THE ELECTRIC
UTILITY METER.
APPRO ED AS NOT D L
2 4. IF IT IS NOT PRACTICAL TO LOCATE THE AC DISCONNECT WITHIN VIEW OF W
DATE: ✓ B.P. THE UTILITY METER, THEN A WEATHERPROOF PLAQUE SHOWING THE LOCATION Lc a
OF THE SWITCH MUST BE INSTALLED WITHIN VIEW OF THE ELECTRIC UTILITY
M ' A I N B A Y V I E W R D METER.
FEE: i ._b BY:
NOTIFY BUu:_;d(3 DEP-••,: TIENT AT 5. ALL WIRING TO MEET THE NATIONAL ELECTRICAL CODE.
J
765-1802 8 ATN TO 4 FM FOR THE 6. THE RAFTERS AS INDICATED HAVE BEEN ANALYZED AND DEEMED SUFFICIENT
TO SUPPORT THE ADDED LOAD OF THE SOLAR PANELS AND CONNECTORS. (o I— Fa— L)
FOLLOWING INSPECTIONS: (n
0 7 THE SOLAR PANELS MAY NOT BE INSTALLED ON AN EXISTING ROOF THAT
1. FOUNDATION - TWO REQUIRED Kj HAS MORE THAN 1 LAYERS OF ASPHALT ROOF SHINGLES, UNLESS ADEQUATE z Q
FOR POURED CONCRETE 00 MEANS OF SUPPORT ARE PROVIDED AS PER THESE DRAWINGS. 0 -- 00
Lli
2 .ROUGH - F,i c`"•a� '•" PL®N '50"E 200.00, r S. THE MAXIMUM SPACING BETWEEN THE STANDOFFS SHALL BE 66" O.C. r-
3, W U U c
Go
3. INS LAT Lo
9. THE SOLAR PANEL MOUNTING SYSTEM WILL BE BY UNIRAC WITH A 2 1/2" � Z Z Q Q01)
4. FIN L - i MUST ALUMINUM "I" BEAM. Q W !Y �
BE Oml , w.•. • CL 0 lY 0
ALL NST" SHALL MEET THE O ZONING INFORMATION Fn FW— - o
RE IREMEV C.,-` THE CODES OF NEW D R I V E W A Y o Of LLJ c)
YOARISTATE. NOT RESPONSIBLE FOR 6 STREET ADDRESS: 1745 WATER TERRACE g �/ of W
DESIGN OR CONSTRUCTION ERRORS. SOUTHOLD, NY 11971
W �- �
LrJSECTION: 88 BLOCK: 6 LOT ( S ): 13.13 O J Q Z z z
J
v LINE DIAGRAM � 0
23
JOMPLY WITH ALL CODES OF I < O � O °
NEW YORK STATE & TOWN CODES N N STRING , CONNECTED TO PV MODULES -� Q
AS REQUIRED AND CONDITIONS OF STRING 2 CONNECTED TO PV MODULES �: /O I� � � 0 o
STRING 3 CONNECTED TO PV MODULES m CL
z
2.0' 2.0 w 0 :D W F_
NG BOARD o a �0 O w
M0aD_m►�+�rRo. I1REES 2 STORY SOLECTRIA XANTREX XANTREX W
DWEWNG3000 an GT30 Z
ro EXISTING
N EXISTING 200 AMP
METER
HOU E IN DDCSCONNECT DISCONNECT DISCONNECT O
W0 INTEGRATED INTEGRATED lr. J O Lia �_ W
W (Z z rT,
w l m 59.0' I o TOTAL SYSTEM SIZE: 6.72 kWa (Y ; Z W N
O
W Wg N Q
I ,D.D• � a Z � �
— 0 =
N I N ATTACHMENT DETAIL V) ^ mo o
z co
ro v
SOLAR PANEL MODULE U),^
m� ^p
N 66.10'50"W 200,00' ' ALUMINUM ALLOY L-FOOT STANDARD RAIL BY UNIRAC '� n,l
ASPHALT FV FLASHING
ELE"RICA ROOF SHINGLE
OCCUPANCY OR
11191PEC'FlON REQUIRE® A
USE IS UNLAWFUL EXISTING ROOF A
SHEATHING ,
5/16'X 4 1/2'STAINLESS STEEL
EXISTING ROOF RAFTER LAG BOLTS INTO CENTER OF ROOF
WITHOUT CERTIFICATE RAFTER, MINIMUM 3' EMBEDMENT
OF OCCUPANCY F F1NE`N
' 9
JOB NO.
201 7—SO2025
THE ACTUAL IN-FIELD ATTACHMENT TO THESE DRAWING COMPLY WITH THE
THE ROOF WILL MEET OR EXCEED NYS 2015 IRC NEW YORK STATE
RESIDENTIAL CODE REQUIREMENTS RESIDENTIAL BUILDING CODE.
UL
THESE DRAWING HAVE BEEN DESIGNED IN NOTE: ALL ROOF MOUNTING
ACCORDANCE WITH THE (AF & PA) WOOD BRACKETS SHALL BE PROPERLY EX. ROOF VENTS Z
FRAME CONST. MANUAL FOR ONE AND TWO a SECURED TO A ROOF RAFTER. w
FAMILY DWELLINGS. w ¢ Q
0 18" MINIMUM cl,
O VENT AREA
EX CHIMNEY _1
GROUND ACCESS POINTS ARE NON-OBSTRUCTED 36" MINIMUM -i F,.,
PER 2015 IRC NEW YORK STATE RESIDENTIAL / ROOF ACCESS Q
BUILDING CODE. CO 1— U
UTLINE OF ROOF 36" MINIMUM `-" V) Z w
HATCHED AREA INDICATES GROUND ACCESS Z O O � co
L
EX. SKYLIGHT W C
LOCATION OF SOLAR PANELS m
ROOF PLAN/PANEL LOCATION w w U Q W Lo
r-
SCALE 1/16"=1'-0" o Q W cU m
2" X 10" RIDGE W W r W
Ljj �-
0
PRIOR TO CUTTING OR ORDERING OF MATERIAL
O
2" X 4" COLLAR TIES 48" O.C. of
OR PLACEMENT OF THE L-FOOT ATTACHMENT, Q — H �; U 3
12 FIELD VERIFICATION OF EXACT RAFTER W --1 Q z
2" X 8" ROOF RAFTER @ 16" O.C. 1 LOCATIONS ARE REQUIRE TO COMPENSATE FOR j O
PREEXISTING RAFTER IRREGULARITY THAT MAYm o
EXIST. O W :2In �J x
ALUMINUM STANDOFF AND L-FOOT
CLIP LAG BOLTED TO RAFTER z ~ LL_ �, z
HYUNDAI 280W SOLAR MODULES CE
--- --- o W I° O O) cr- w
w
ALUMINUM SUPPORT
RAIL BY UNIRAC W 0
0 J �
EXISTING ASPHALT ROOF SHINGLES ¢
(MAX 1 LAYER) ON 15# BUILDING ATTIC
W N Q z
PAPER ON 1/2" PLYWOOD SHEATHING � Z _
0 � O ^ d~ O
z Lo 2:
v `-
0 V) W
� D ARCy
3.
ROOF CROSS SECTION
F OF E�
SCALE 3/8"=1'-0"