Loading...
HomeMy WebLinkAbout42134-Z Town of Southold 2/7/2018 P.O.Box 1179 53095 Main Rd AL # Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39499 Date: 2/7/2018 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2780 Boisseau Ave., Southold SCTM#: 473889 Sec/Block/Lot: 55.-6-10 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/30/2017 pursuant to which Building Permit No. 42134 dated 11/13/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF-MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Perez,Victor of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 42134 01-16-2018 PLUMBERS CERTIFICATION DATED Authorized Signature TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE ' SOUTHOLD, NY xl BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 42134 Date: 11/13/2017 Permission is hereby granted to: Perez, Victor 2780 Boisseau Ave Southold, NY 11971 To: install roof-mounted solar panels on existing signie-family dwelling as applied for. At premises located at: 2780 Boisseau Ave., Southold SCTM #473889 Sec/Block/Lot# 55.-6-10 Pursuant to application dated 10/30/2017 and approved by the Building Inspector. To expire on 5/15/2019. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. 10 1-30 11.77 New Construction: Old or Pre-existing Building: (check one) Location of Property: d 9 r6, 0 1;01 SSPQ U Av&g,- SOJ400- House No. Street Hamlet Owner or Owners of Property: l h Q Suffolk County Tax Map No 1000, Section D 55 oo Block Q6 00 Lot 0) Q0/)0 Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: ( n p Health Dept.A roval: Underwriters Approval: Planning Board Approval: Request for: Tempora prtificate Final Certificate: (check one) Fee Submitted: $ Applicant Signature pF SO!/lyQl 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road cn Fax(631)765-9502 P.O.Box 1179 G • OQ roper.richert(cD-town.southold.ny.us Southold,NY 1 1 971-0959 'Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Victor Perez Address: 2780 Boisseau Avenue city Southold st: New York zip: 11971 Building Permit* 42134 Section: 55 Block: 6 Lot: 10 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Sun Run Solar License No: 33878-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures f] TVSS Other Equipment: 6.930 KW Roof Mounted Photovoltaic System to Include 21- LG 330 Panels, 1- SE 6000 Inverter, AC Disconnect. Notes: Inspector Signature: /) Date: January 16, 2018 0-Cert Electrical Compliance Form.xls pF SO�lyolo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION ( ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) REMARKS: DATE 1 INSPECTORi 152 S. Broad St. APPennFUSION Lansdale, PA 19446 E n g 1` n e e r I n g (215)361-8040 December 20, 2017 Sunrunlnc. 15 Charlotte Ave Hicksville, NY 11 801 RE: Perez Residence 2780 Boisseau Ave, Southold, NY 11971 Client Project#• 21111-780PERE PFE Project#: 172090 Install Date: December 18, 2017 Permit#:42134 On behalf of Sunrun Inc., Penn Fusion Engineering LLC(PFE) has reviewed the documentation on the installation of the photovoltaic system at the above referenced location. This office has verified that the PV panels have been installed per the manufacturer's specificaitons and complies with the approved plan of the local jurisdiction and has met or exceeds the New York State Residential building code and the provisions of ASCE 7-05 and ASCE 7-10 If you have any questions regarding this analysis, please feel free to contact us Best Regards, Penn Fusion Engineering LLC Andrew D. Leone, P.E. Principal (�OF NEW Y D ���0 V 1:9 IV"OOMENiC�O�Q% JAN 3 1 2018 = �= ` w r h Z BUILDING DEPT. 's;`' op;1 3 TOWN OFSOUTHOLD F` FIELD INSPECTION REPORT I DATE COMMENTS FOUNDATION(1ST) ------------------------------------- FOUNDATION (2ND) (v O O v� ROUGH FRAMING& glm-�PLUMBING 1 O r INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS ro o �z rn � o Z � x � d b y TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Suryey SoutholdTown.NorthFork.net PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined ,20VI 0 QM� Single&Separate Storm-Water Assessment Form Contact: Approved ,20 OCT 3 0 2017 Mail to: 415 Oser Ave Disapproved a/c TOWN OF SO Ste. W, Hauppauge NY 11788 $ '�°�C"t Phone: 631-304-9901 Expiration 5 20 Buil ' for C1_10 i1n APPLICATION FOR BUILDING PERMIT Date 10/30 , 2017 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale. Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations, for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant o name,if a corporation) 415 Oser Ave, Ste. W, Hauppauge NY 11788 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Agent Name of owner of premises Angelina Perez (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authonzed officer Samy Mounas-Master Electrician 5.,A4,,, (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. 33878 Other Trade's License No. 1. Location of land on which proposed work will be done: 2780 Boisseau Ave Southold House Number Street Hamlet County Tax Map No. 1000 Section 05500 Block 0600 Lot 010000 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost $13,805.00 Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded?YES NO Will excess fill be removed from premises?YES NO 14.Names of Owner of premises Agenlina Perez Address27e0 soissm Ave Southold 11w1Phone No. (631)7W-7759 Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO V * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO V * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property? * YES NO—V * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk ) ccy)'oI 1 -'1 0 ,(\ being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing cco ract)above named, (S)He is the 1✓0-� (04Aractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to be ore me this 30 da of 10 20 17 THOMAS DE-GEROP111 O State of New Y ubl Signature o licant I�ln 01 i E633R�s."3 g pp Qualified in Nlassau County, Commission Expires March 21, 20— t �d Town Halt Annac Tckpbont(681)765-ISM 54873 Mak Road PA-Boz 1179 mer rICI161LEiBi0Y11111�'CI�f1V US SaudwK NY 119714959 BUE DWG DF.PARTMFI T TOWN OF SOUMOLD APPLICATION FOR E E ICAL INSPECTION F UESTED BY: Date: I " pany Name: e: almA. AA License No.: "Ma: is -is - jPhone No.: l 631- 0%°�4- Oo.t.� JOBSITE INFORMATION: (*Indicates required information) Name: �, r "Address: "Cross Street: 'Phone No.: _ _ - Pamlt No.: 69I 1A Tax-Map District: 1000 Section:�5 Block: 4 Lot: 10 *BRIEF DESCRIPTION OF WORK(Please print Clearly) 61.300 fG ��,I% kw 1_ s CSIJ,6 -jeqA7�0 Lm -AS s.1o,r LA(� 11U�y My1,\l ro / (Please Circle All That Apply) CI ) U,--�54 �J is nnwac 'Is job ready for inspection: S NO Rough In Final *Do you need a Temp Certificate: YES Tamp Infomudom ) *Service Size: 1 3Phase 100 150 O 300 350 400 r "New Service: Underground Number of Meters Change of Serv'be ead Additional Information: PAYMENT DUE WITH APPLICATION -- tins 1j,- �P t 824Ugrreet for lnwoc uon Form *pF SO(/ryQlo Town Hall Annex Telephone(63 l)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1 179 G • Southold,NY 11971-0959 'Q 114UNTY,� January 18, 2018 BUILDING DEPARTMENT TOWN OF SOUTHOLD Sun Run Solar 415 Oser Ave, Ste W Hauppauge, NY 11788 Re: Perez, 2780 Boisseau Ave, Southold TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: NOTE: Post installation certification letter required to close out building permit Electrical Underwriters Certificate 2 A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 42134- Solar Panels 152 S.Broad St Penn FUSION Lansdale,PA 19446 E n g n e e r i n g (215)361-8040 October 23,2017 Subject:Structural Certification for Proposed Residential Solar Installation. Job Number:211R-780PERE; Plan Set: Rev A.1, Dated 10/12/17 Client:Victor Perez Address:2780 Boisseau Ave,Southold, NY, 11971 Attn:To Whom It May Concern A field observation was performed to document the existing framing of the above mentioned address. From the field observation,the existing roof structure was observed as 1 layer Composition Shingle roofing over roof plywood supported by 2x6 Rafter @ 16"OC. The roof is sloped at approximately 30 degrees and has a max rafter span of 9'4" between supports. Design Criteria: • 2016 New York State Building Code(2015 IBC&IRC) • Basic Wind Speed Vult= 130 mph (Vasd= 101 mph), Exposure B • Ground Snow Load =20 psf Our analysis is based on the information provided by Sunrun Inc.and is isolated only to the areas where the modules are intended to be placed. After review of the field observation report,the existing roof framing supporting the proposed solar panel layout has been determined to meet or exceed the requirements based on our structural capacity calculations in accordance with applicable building codes. Therefore, no structural upgrades are required. If you have any further questions on the above for mentioned,please do not hesitate to call. OF N 4, Sincerely, � p0M6 N"d Penn Fusion Engineering LLC *;Q t e ti Q rn W S � � SOA. 081693 Nv Andrew D. Leone, P.E. ApFESS1C3NA Principal oil Suffolk County Department of Labor, Licensing & Consumer Affairs VETERANS MEMORIAL HIGHWAY * HAUPPAUGE, NEW YORK 11788 ` DATE ISSUED: 10/1/2003 No. 33878-ME i SUFFOLK COUNTY x Master Electrician License e This is to certify that SAMY A MOUNAS # doing business as SUNRUN INSTALLATION SERVICES INC i having given satisfactory evidence of competency, is hereby licensed as MASTER ELECTRICIAN in accordance with and subject to the provisions of applicable laws,rules and regulations of the County of Suffolk, State of New York. Additional Businesses NOT VALID WITHOUT DEPARTMENTAL SEAL AND A CURRENT j CONSUMER AFFAIRS 1D CARD r� Acting Commissioner ( f i t DATE MM/D A� CERTIFICATE OF LIABILITY INSURANCE 9/11/21017 Dom) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Arthur J.Gallagher&Co. NAME: PHONE 415 546-9300 FAX 415-536-8499 Insurance Brokers of CA. Inc.License#0726293 E-MAIL 1255 Battery Street#450 San Francisco CA 94111 INSURERS AFFORDING COVERAGE NAIC# INSURER A.Zurich American Insurance Company 16535 INSURED SUNRINC-01 INSURER B.Navigators Specialty Insurance Company 36056 Sunrun Inc. INSURER C. 595 Market Street, Floor 29 INSURER D San Francisco,CA 94105 INSURER E. INSURER F: COVERAGES CERTIFICATE NUMBER: 1379443839 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDLISUBRI TYPE OF INSURANCE POLICY EFF POLICY EXP LTR INSD WVD POLICY NUMBER MMIDD MMIDDIYYYY LIMITS B X COMMERCIAL GENERAL LIABILITY Y LA17CGL2303211C 10/1/2017 10/1/2018 EACH OCCURRENCE $1,000,000 CLAIMS-MADE X�OCCUR DAMA E T RENTED PREMISES Ea occurrence $300,000 X $50.000Retention MED EXPAn ( y one person) $5,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 X POLICYFX�JEo LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: Total Policy Limit $10,000,000 A AUTOMOBILE LIABILITY Y BAP915542504 10/1/2017 10/1/2018 COMBSINGLE LIMIT INED $2,000,000 A1NY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE AUTOS ONLY AUTOS ONLY Per accident $ X UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB HCLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ A WORKERS COMPENSATION WC013696003 10/1/2017 10/1/2018X PER OTH- A AND EMPLOYERS'LIABILITY Y/N WC013696103 10/1/2017 10/1/2018 STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVEE.L.EACH ACCIDENT $1,000,000 OFFICER/MEMBER EXCLUDED? ❑ N/A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEd$1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT 1$1,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) WC013696003-$25,000 Deductible;WC013696103-FL, HI, MA, NJ, NY,OR,VA,WI only. Named Insureds:Sunrun Inc.,Sunrun Installation Services Inc.,Sunrun South LLC,AEE Solar, Inc., Clean Energy Experts LLC,Sunrun Solar Electrical Corporation Evidence of insurance CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 53095 Route 25 ACCORDANCE WITH THE POLICY PROVISIONS. Southold NY 11971 AUTHORIZED REPRESENTATIVE C 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD SUFFOLK COUNTY DEPT OF LABOR, LICENSING&CONSUMER AFFAIRS MASTER ELECTRICIAN NAM 99% SAMYA MOUNAS This certifies that the MNE2 NAME bearer is duly SUNRUN INSTALLATION SERVICES INC licensed by the County of Suffolk `�~""'� r�T 33878-ME 10/01/2003 (7.u.u/�edlC 10/01/2019 IWNWoRK rkers' CERTIFICATE OF INSURANCE COVERAGE ATE Compensation UNDER THE NYS DISABILITY BENEFITS LAW Board PART i To Be completed by Disability'Benefits carrier or Licensed Insurance Agent of that Carrier Ia.Legal Name& address of Insured(Street address orth) j In Business Telephone Number of � Sunrun Installation Services Inc. losurod (405) 540-7643 775 Fiero Lane,Suite 200 Ic NYS L,nemplovmcnt Insurance Employer Registration Nutnberof San Luis Obispo,CA 93401 i Insured Id Federal Employer Identification Number of insured or Jocial Securiq number 77-0471=107 ?. Nautc and kddress ofthe F ntity Requesting Prool'of(overage 3a Name of Insurance Canter (Entity Being Listed asthe(ertdicationHolder) MU FURL OF UNIAHA 3b Policy Number ofentiv.listed in box"la", Town of Southold GM1NY6X007P67-0001 53095 Route 25 Southold,iV t, 11971 3c Poiicyeec,'ti epentk 311115/2017— 3/15/2018 15%_018 4.Policy covers: a. X All of the employers employees eligible under the New York Disability Benefits law b. Only the following class or classes of the employer s employees Under penalty of perjury,I certify that I am authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability insurance coverage as described above n/ Date Signed 6;"16;`2017 Bl 17'Cr 4 RW" -gt;ature of arriet',auth,,rinYi representatixe(currently on file tyith DB Bureau) I-cl.No.. (914-591-7111) Title DISABILM .ADMINISTRATOR INIKAT-LN F If bot'4a'is,he ked,and this liim:is awed by:he insurance carries s autlwrinYl wpresentaticc or%1 S I:censed Insunnce \,enr of that airier, This certificate is Completed.Mail it directly to the certificate holder if No, 4b-is checked,this certificate is N0'i C'ONIPL. FE for purposes of Jectton 220.Subd.8 4the Disabdtt%Benefits Lau It must be mauled for c,,mpleto m to the\\orkers Compensation Board,DB Plans Acceptance t mt,'-0 Park Street.Albany,Ne\N fork 11207 TO BF C'()'1tPLFTF.D M NYS WORK R'S CONiHNSATION BO-kRD.(,On1k_Lfbo�-b-of Part'-has been checkedl STVI E Of\EW ItORK NNORKERS'COMPENSATION BOARD According to inf rnialion mamiained by the Nti S\\orkcis (ompensation Board,the aho%e-named emphryer has complied��iih the NYS Disahiiity Benefits Law anh respect to all of his-her cnnployces Date Signed -------- - B\ i (Sienature ot'Nl`S llrrku,'C'ompcnsanon Boaid Employees) Tel.No.t 1 Title Please Note,Onh Insurance carriers,licens,Yd to%t rite Nl'S disability bcnefirs insurance policies and NYS licenses insurance agents of those carriers are authorized to issue Form DB-120 I Insurance brokers are NO f authorized io is.,ue this Ibrm DB120.1 (9-I5) r"o K Workers' CERTIFICATE OF rnrc Compensation Board NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1a.Legal Name&Address of Insured(Use street address only) 1b.Business Telephone Number of Insured (805)528-9705 Sunrun Installation Services Inc. 1c.NYS Unemployment Insurance Employer Registration 775 Fiero Lane,Suite 200 Number of Insured San Luis Obispo,CA 93401-7904 50-864264 Work Location of Insured(On/yrequired ifcoverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or certain locations in New York State,i.e.,a Wrap-Up Policy) Social Security Number 77-0471407 2.Name and Address of the Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Zurich American Insurance Company 3b.Policy Number of entity listed in box"la" Town of Southold WC 0136961-03 53095 Route 25 Southold,NY 11971 3c. Policy effective period 10/01/2017 to 10/01/2018 3d. The Proprietor,Partners or Executive Officers are ® included. (Only check box if all partners/officers included) ❑ all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box "3" insures the business referenced above in box "la" for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". Will the carrier notify the certificate holder within 10 days of a policy being cancelled for non-payment of premium or within 30 days if cancelled for any other reason or if the insured is otherwise eliminated from the coverage indicated on this certificate prior to the end of the policy effective period?®YES ❑NO This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend,extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the workers' compensation policy indicated on this form, if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers' Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Kelly Cada (Print name of authorized representative or licensed agent of insurance carrier) Approved by: 09/21/2017 (Signature) (Date) Title- Vice President-Enterprise Support Operations Telephone Number of authorized representative or licensed agent of insurance carrier: 800-382-2150 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to Issue it. C-105.2(9-15) www.wcb.ny.gov O AP ROVED AS NOTED DATE: 3 B.?. FEE: y �SY NOTIFY B"i NT AT ELECTRICAL. 765-1802 8 Xv1 FOR THE INSPECTION REQUIRED FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURE"' ' :9ETE 2. ROUGH - PLUMBING 3. INSULA 1 4. FINAL MUST BE CON. ALL CONS' SHALL MEET THE REQUIREME HE CODES OF NEW RETAIN STORM UVATER RL�'.`"f F YORK STATE. AC)i RESPONSIBLE FOR PURSUANT TO CHAPTER 21'J�6 DESIGN OR CONSTRUCTION ERRORS. OF THE TOWN CGDE. COMPLY WITH ALL CODES OF NEW YORK STATE g. Tr)!VN' C'(-)DES AS REQUIRED AlvD -'NS OF -4QLZH()l-n 104N 7P4 S RD SII ST€ES OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICAT'- OFOCCUPANCY 152 S.Broad St Penn FUSION Lansdale,PA 19446 E n g i n e e r i n g (215)361-8040 October 23,2017 Subject:Structural Certification for Proposed Residential Solar Installation. Job Number:211R-780PERE; Plan Set: Rev A.1, Dated 10/12/17 Client:Victor Perez Address:2780 Boisseau Ave,Southold, NY, 11971 Attn:To Whom It May Concern A field observation was performed to document the existing framing of the above mentioned address. From the field observation,the existing roof structure was observed as i layer Composition Shingle roofing over roof plywood supported by 2x6 Rafter @ 16" OC. The roof is sloped at approximately 30 degrees and has a max rafter span of 9'4" between supports. Design Criteria: • 2016 New York State Building Code (2015 IBC& IRC) • Basic Wind Speed Vult= 130 mph (Vasd = 101 mph), Exposure B • Ground Snow Load =20 psf Our analysis is based on the information provided by Sunrun Inc. and is isolated only to the areas where the modules are intended to be placed. After review of the field observation report,the existing roof framing supporting the proposed solar panel layout has been determined to meet or exceed the requirements based on our structural capacity calculations in accordance with applicable building codes. Therefore, no structural upgrades are required. If you have any further questions on the above for mentioned, please do not hesitate to call. SOF NE41 Sincerely, �P� p M,y� 0 Penn Fusion Engineering LLC rn �t y \R p8 X693 A��� Andrew D. Leone, P.E. pFESS�ON Principal Penn FUSION 152 S.Broad St En g i n e e r i n g Lansdale,PA 19446 (215)361-8040 Structural Calculations for the Victor Perez Residence PV Installation Date: 10/23/2017 Job Address: 2780 Boisseau Ave Southold, NY, 11971 Job Number: 21111-780PERE Scope of Work These calculations are for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Calculation Index Sheet Description 2 Structural Geometry,Live Load,Snow Load,Wind Load,&Dead Load 3 Roof(1) Framing Check 4 Roof Attachment Check,Seismic Check,&Scope of Work Engineering Calculations Summary Code: 2016 New York State Building Code(2015 IBC&IRC) ASCE 7-10 Snow Load: S= 20 psf Live Load: LL= 20 psf Wind: Wind Speed Ult. (V)= 130 mph Exp.= B PV Dead Load: DPV= 3.0 psf SOF rrE41, Sincerely, Penn Fusion Engineering LLC Andrew D. Leone, P.E. a m Principal 5 ' e �0 081693 \OFESS��N Engineer:SVL Date:10/23/2017 Penn FUSION Job:211R-78OPERE E n g i n e e r i n g Address:2780 Boisseau Ave -- Southold,NY,11971 2of4 Structrure Geometry: Mean Roof Height,hn = 14 ft Eave Height,he = 8 ft Buiding Length,L = 35 ft Building Width,B = 32 ft Module Area = 20 ft2 Roof Pitch,9 = 30 degrees Live Load: Roof Live Load,Lr = 20.00 psf Equation 4.8-1 Snow load: Ground Snow Load,pg = 20 psf Fig.7-1 Snow Importance Factor,Is = i Table 1.5-1 Thermal Factor,Ct = 1.1 Table 7-3 Exposure Factor,Ce = 0.9 Table 7-2 Roof Slope Factor,Cs = 0.73 Figure 7-2c Flat Snow Load,PF = Sloped Roof Equation 7.3-1 Sloped Roof Snow Loads,Ps = 10.16 psf Equation 7.4-1 Is the width of the roof>20ft? Yes Drift Height,hd = 1.23 ft Figure 7-9 Roof slope for a rise of one,S 1.73 Unbalanced Width = 4.32 ft Fig 7-5 v = 17 pcf Equation 7.7-1 Unbalanced Snow Load = 25.70 psf Fig 7-5 Wind Load: Basic Wind Speed(3s-gust),V = 130.0 mph Figure 26.5-3A Building Occupancy Category = 2 Table 1.5-1 Exposure Category = B Sec 26.7.3 Topographic Factor,Kzr = 1.00 Equation 26.8-1 Adjustment Factor,A = 1.00 Figure 30.5-1 Edge Zone,a = 3.20 ft Figure 30.5-1 Uplift(0.6W1 Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnetm = -28.90 -34.00 -34.00 Figure 30.5-1 Peet=0.6 x A x Kzr x Pnetw) _ -17.34 -20.40 -20.40 Equation 30.5-1 Downward(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnew = 27.00 27.00 27.00 Figure 30.5-1 Pnet=0.6 x A x Kzr x Pnem = 16.20 16.20 16.20 Equation 30.5-1 Dead Load: Rofl: Roof Walls-Exterior Composition Shingle 3.0 psf Wood 5.0 psf 5/8 OSB Sheathing 2.0 2x4 Studs @ 16" 2.0 2x6 Rafter @ 16"OC 2.0 Gypsum 3.0 Misc.(Ceiling,Insulation,etc.) 1.0 Misc.(Insulation,etc.) 2.0 PV System,Ppv 3.0 Total Roof DL= 11.0 psf Total Wall DL= 12.0 psf Engineer:SVL Date:10/23/2017 l Penn FUSION Job:211R-78OPERE E n g i n e e r i n g Address:2780 Boisseau Ave Southold,NY,11971 3of4 Hoof(1)Framing Check: Roof Framing = 2x6 Rafter @ 16"OC Timber Species = Doug Fir-Larch#2 Max Beam Span = 9.33 ft b = 1.5 in d = 5.50 in Moment of Inertia,Ix = 20.80 in Section Modulus,Sx = 7.S6 in Bending Stress,Fb = 900 psi Elastic Modulus,Emin = 580000 psi CD(Wind) CD(Snow) CLS CM Ct Wood Adjustment Factors: 1.60 1.15 1.00 1.00 1.00 CL CF Cru G Cr 1.00 1.30 1.00 1.00 1.15 PV Tributary Width,Wpv = 2.75 ft PV Tributary Length,Lpv = 4.0 ft PV Tributary Area,At = 11.0 ft' PV Dead Point Load,PD=Ppvx At = 29 Ib Roof Distributed load,wDL = 9 plf Load Case: 0.6DL+0.6W ICD=1.61 Roof Zone = 1 Pup=Pnet x At+0.6 x PD x Cos(6) = 174 Ib Mb(wmd_up) = 511 Ib-ft Fb'(vdnd)=Fb xCD xCLs xCM xCt xCL xCF xCfu xG xCr = 2153 psi Maliowable=Sx x Fb'(wind) = 1357 Ib-ft > 511 OK Load Case: DL+0.6W ICD=1.61 Pdown=Pnet x At+PD x eos(9) = 207 Ib Mb(wind_down) = 781 lb-ft Fb'(wind)=Fb xCD xCLs xCM xCt xCL xCF xCfu xG xCr = 2153 psi Mallowable=Sx x Fb'(wind) = 1357 Ib-ft > 781 OK Load Case: OL+0.75(0.6W)+0.75S (CD=1.61 Roof Snow Distributed Load,w5L = 14 plf Psnow=Ps x At = 97 1 b Mb(wind_snow) = 873 ib-ft Fb'(wind)=Fb xCD xCLs xCM xCt xG.xCF xCfu xG xCr = 2153 psi Mailowable=Sx x Fb'(snow) = 1357 Ib-ft > 873 OK Load Case: DL+S (CD=1.151 Roof Snow Distributed load,wSL = 14 plf Psnow=Ps x At = 97 1 b Mb(snow) = 5131b-ft Fb'(snow)=Fb xCD xCLs xCM xCt xCL xCF xCfu xG xCr = 1547 psi Maliowade=Sx x Fb'(snow) = 975 Ib-ft > 513 OK Engineer:SVL Date:10/23/2017 0 Penn FUSION Job:211R-780PERE En, g i n e e r i n g Address:2780 Boisseau Ave Southold,NY,11971 4of4 Rafter Attachments:0.6D+0.6W(Zone 2) Pupi t=At x Pnet = 207 Ib Connector Uplift Capcity per SnapNRack Test Results = 500 Ib > 207 OK 5/16"Lag Screw Withdraw!Value = 266 Ib/in Table 12.2A-NDS Lag Screw Penetration = 2.5 in Allowable Capacity with Co = 1064 Ib > 207 OK Seismic Check: Existing Dead Load: Solar Dead Load: Aroae,dsvng = 1120 ft' Wp■nel = 42 lb Wrooreds" = 8960 lb Numponed = 21 Awaiio*dng = 1072 ft2 Wpenel_mt = 882 Ib Wwalledstin` = 12864 Ib Wb. = 206 lb MOW = 21824 Ib Weeny = 1088 lb y6mcrease=iwtotal+Warray)/Moa! = 22912 '100%-100% = 4.98% " 21824 "The increase in weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis Is required. Limits of Scope of Work and Liability We have based our structural capacity determination on applicable building codes,professional engineering inspection and design experience,opinions and judgments.The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards and procedures. SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TASLEOFCONTENTS PAGE R DESCRIPTION • SYSTEM S12E:6930W DC,8000W AC • ALL WORK SHALL COMPLY WITH 2014 NEC,2015 IBC,MUNICIPAL CODE,ANDSERVICE ENTRANCE SOLAR MODULES PV-1.0 COVER SHEET SE • MODULES:(21)LG ELECTRONICS:LG330N1C-A5 ALL MANUFACTURERS'LISTINGS AND INSTALLATION INSTRUCTIONS. RAIL PV 2.0 SITE PLAN • INVERTER(S): • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2014 NEC. (1)SOLAREDGE TECHNOLOGIES:SE6000H-US WITH • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2014 NEC. MAIN PANEL -" '- PV-3.0 LAYOUT REVENUE GRADE METERING • PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY _ PV-3.1 ATTACHMENT DETAIL • RACKING:SNAPNRACK SERIES 100 UL,FLASHED L FOOT GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 890.35. SEE PEN D01 • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SP SUB-PANEL STANDOFFS b PV-4.0 ELECTRICAL • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741 _Y FOOTINGS PV-4.1 ELECTRICAL CALCS • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ,,, CHIMNEY • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). LC PV LOAD CENTER PV-6.0 SIGNAGE • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT • 9.88 AMPS MODULE SHORT CIRCUIT CURRENT ATTIC VENT • 15.09 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)3 890.8(b)]. SM SUNRUN METER _ FLUSH ATTIC VENT PM DEDICATED PV METER PVC PIPE VENT INVERTER(S)WITH INTEGRATED DC METAL PIPE VENT / Q F N!yy� INV DISCONNECT AND AFCIM �z T-VENTP/D� �hi AC AC DISCONNECT(S) I* p� r LEO SATELLITE DISH DC DC DISCONNECT(S) FIRE SETBACKSREM Fz �O\A 081893 (] COMBINER BOX I. HARDSCAPE OFes8 INTERIOR EQUIPMENT —PL— PROPERTY LINE NTS s u n ru n L:)j SHOWN AS DASHED A AMPERE AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER 54139-ME AZIM AZIMUTH VICINITY MAP COMP COMPOSITION "Cw• AVI Hl[ •I Wli DC DIRECTCURRENT ■ro•mm+ (E) EXISTING rtemm= EXT EXTERIOR CUSTOMER RESIDENCE, FNM FRAMING LOAD BE VICTOR PEREZ INT 2780 BOISSEAU AVE, LBW LOAD BEARING WALL MAG MAGNETIC SOUTHOLD,NY,11971 Orient (MSP MEAtIINN SERVICE PANEL ,a 1•D+11e•.arsa APN•, ODW NTS NOT TO SCALE PROJECT NUMBER' OC ON CENTER 211R-78OPERE Greenport PRE-FAB PRE-FABRICATED DESIGNER 303.9422528 PSF POUNDS PER SQUARE FOOT 12780 BOdSSNu Avenue PV PHOTOVOLTAIC ANDREW HOFFMAN TL TRANSFORMERLESS DRAFTER TYP TYPICAL V VOLTS DIMENSION I W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET Matdtuck Sag Harbor A a i REV'A.1 10/122017 Csl East PAGE PV-1.0 817E PLAN DETAIL-SCALE=IAP=1'-0' PITCH TRUE MAG PV AREA SITE PLAN-SCALE=3HIt"=1 C AZIM AZIM (SOFT) ® AR-01 30' 81' 93' 55.3 AR-02 30' 171' 183' 73.8 AR-03 30' 281' 273' 147.5 AR-04 30' 281' 273' 110.8 (E)RESIDENCE FIRE SETBACKS PL (18'TYP) a (N)ARRAY AR-01 A. (N)ARRAY AR-04 P PL C PL R G m (N)ARRAY AR-02 s u n r u n 54139-ME 15CHVIIpTl[AVE.Hp 1p W 11 PpE=6N FAR- CUSTOMER RESIDENCE. VICTOR PEREZ 2780 BOISSEAU AVE, SOUTHOLD.NY,11971 (N)ARRAY AR-03 TEL(637)7!-TfSY APNP f0000bb000lOODI0000 PROJECT NUMBER: rMF 211 R-780PERE SE AC INV �pF NEyy DESIGNER: HOFFMAN 303.Y422528 pomey� yQ DRAFTER: Ce' � DIMENSION I a m �� SHEET s l"ft SITE PLAN Z�FOp 06*95 REV AA 16d122017 tQFESS pN► PAGE PV 2.O ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF FRAME FRAME TYPE FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL MIGN CRITERIA EXPOSURE MATERIAL SIZE SPAN SPACING ZONE SPAN OVERHANG MODULU: AR-01 COMP SHINGLE FLASHED L FOOT SEE PEN D01 SINGLE STORY ATTIC WOOD RAFTER 2 X 8 9'-4" 18" WA 4'-0" 1'4" LG ELECTRONICS:LG330N1C-A5 AR-02 COMP SHINGLE FLASHED L FOOT SEE PEN DOI SINGLE STORY ATTIC WOOD RAFTER 2 X 6 T-9" 18" N/A 4'-0• 114" MODUL.E DNS: 88.38"x 40"x 1.57"(40mm) AR-03 COMP SHINGLE FLASHED L FOOT SEE PEN DOI SINGLE STORY ATTIC WOOD RAFTER 2 X 6 g'-4" 18" WA 4'-0" 114" MODULE CLAMPB: AR-04 COMP SHINGLE FLASHED L FOOT SEE PEN D01 SINGLE STORY ATTIC WOOD RAFTER 2 X 8 9'-4- 18" WA 4'-0" 1'-4" Portmg: 5.9"-15.7" Landscape:Cr-4.7" D1-AR-01-SCALE:118"=1'-0" D2-AR-02-SCALE:3116"=1'4Y MAX DISTRMUTED LOAD:3 PSF PITCH:30" PITCH:30" SNOW LOAD:20 PSF AZIM:81" AZIM:171* WIND SPEED: ® 130 MPH 3-SEC GUST 16'-3" LAO SCREWS: 13'-4" -3%8"- 5H8"x4.0"'2.5"MIN EMBEDMENT NOS: -a —o_ e- INSTALLERS TO VERIFY RAFTER 1'3" SIZE,SPACING AND SLOPED 5I" �4 TYP{d- o- SPANS,AND NOTIFY E.O.R.OF -0- '0; I ANY DISCREPANCIES BEFORE PROCEEDING. 1{ 4'TYP-{1 _ 5$" PENEMTIO PACING: STAGG�� F NEyy y - /1 j OOMEry� -- 2'11• ��,Q�� nCl�9'!�\ 1�( y�FO\ 08 t89'3 D3-AR-03-SCALE:118"=1'-0" D4-AR-04-SCALE:3H8"=1'-0" s u n PITCH:30" PITCH:30" AZIM:261' AMM:261' ® -13'-5". ® 1'- —8'-3"— 54139-ME %cwN.a hw� 'w wvnog P�06�06DIObU1 1'3" 1'317 F,uteawaaa -° CUSTOMER RESIDENCE. QI O VICTOR PEREZ 14'TYP-} 2780 SOISSEAU AVE, SOUTHOLD,NY,11971 -e e -O-- --O - qq---- lEL(Qi1)7M777Y A►NI t000D57000lDOD1000D -}4'TYP 1r-1• -O- PROJECT NUMBER: -a-o-- -g- -'a -G -o - 211R-780PERE 3'-W DESIGNER 303.942152! ANDREW HOFFMAN DRAFTER: DIMENSION I SHEET LAYOUT REV Al 10/12/2017 PAGE PV-3.0 STEP 3:PLACE L FOOT ON TOP OF NOTES: FLASHING AND TIGHTEN NUT -5/16"LAG BOLTS MUST EMBED 2.5"INTO ROOF SNAPNRACK STRUCTURAL MEMBERS/RAFTERS STEP 2:SLIP FLASHING OVER L COMPOSITION L FOOT 5/16"S.S.FLANGE NUT -TORQUE ALL 5/16"HARDWARE TO THE FOLLOWING. FOOT BASE AND UNDER ROW OF CAN BE MOUNTED IN -SILVER S.S.10-16 FT-LBS SHINGLES ABOVE ANY ORIENTATION -BLACK S.S.7-9 FT-BLS 5/16"X 1"(OR 1.25") -RAILS CAN MOUNT TO EITHER SIDE OF L FOOT SNAPNRACK S.S.BOLT AND SPLIT (UPSLOPE VS DOWNSLOPE) CHANNELNUT WASHER I . ® O 5/16"S.S.LAG SCREW WITH FLAT WASHER,2.5"MINIMUM SNAPNRACK EMBEDMENT IS STANDARD STANDARD RAIL STEP 1 BOLT L FOOT BASE TO ROOF WITH SNAPNRACK COMPOSITION LAG BOLT ROOF FLASHING ROOF DECKING TYP SNAPNRACK L FOOT BASE s u n ru n 0 54139-ME ncwria*�ve cw"vwF"vna+ PYg1E pJDOli1 COMPLETED ROOF DECKING TYP INSTALLATION CUSTOMER RESIDENCE. VICTOR PEREZ 2780 BOISSEAU AVE, SOUTHOLD,NY,11971 FLASHED L FOOT MOUNTING POINT FOR USE ON IEL(131)7„-T7W,a„#, „W, RAFTER TYP COMPOSITION ROOF SURFACES WITH LOW TO MODERATE TILT PROJECT NUMBER: 211R-780PERE RAILS CAN BE LEVELED UP TO 3”USING UP TO TWO DESIGNER: 303.9422529 LLEVELING EVELING" ME- AS SHOWN IN"SERIES 100 RAIL �COF NE ANDREW HOFFMAN `�pO ME- 09 DRAFTER: DIMENSION I SHEETATTACHMENT �uj f DETAIL 08X93 % / REV'A.1 10/12=17 PEN DETAIL 01, FLASHED L FOOT TO RAFTER \°goFF s PAGE PV-3.1 120/240 VAC SINGLE PHASE SERVICE METER S' OPSEGLI 23707785 ACCOUNT#' UTILITY 9634811405 GRID EXISTING 1 200A MAIN BREAKER 1 (END FED) EXISTING 200A SOLAREDGE TECHNOLOGIES MAIN (N)LOCKABLE SEBOOOH-US WITH REVENUE PANEL BLADE TYPE GRADE METERING FACILITY AC DISCONNECT 6000 WATT INVERTER JUNCTION BOX PV MODULES LOADS 2 OR EQUIVALENT 1 LG ELECTRONICS LG330N1C-A5 3 ewe 3 (21)MODULES OPTIMIZERS WIRED IN(1)SERIES OF(13) OF NEW OPTIMIZERS AND(1)SERIES OF(8) P 00 N fihYO 36A PV noun SQUARE D LOAD RATED DC DISCONNECT OPTIMIZERS /� BREAKER AT DU222RB WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZER +• t F F OPPOSITE END 3R,60A,2P COMPLIANT P370 a m-¢ OF BUSBAR 1201240VAC i ���J FSA08159 CONDUIT SCHEDULE NOTES TO INSTALLER: 9�FESSIONP� 1 13 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. CONDUIT CONDUCTOR NEUTRAL GROUND 2. ADD 35 AMP PV BREAKER TO MAIN PANEL. S u n ru n 1 NONE (4)10 AWG PV WIRE NONE (1)6 AM BARE COPPER 2 1"PVC OR EQUIV (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 3 1"PVC OR EQUN (2)8 AWG THHN/THWN-2 (1)10 AWG THHWTHWN-2 (1)8 AWG THHN/THWN-2 54139-ME acwAeT,E�vE.HCXN�LIE wv nem vroue eaee"osla F.0 eesaaz CUSTOMER RESIDENCE. VICTOR PEREZ 2780 SOISSEAU AVE, SOUTHOLD,NY,11971 TEL.)!71)7M-7751 AM/1050595050100010500 PROJECT NUMBER MODULE CHARACTERISTICS P370 OPTIMIZER CHARACTERISTICS: 211R-780PERE LG ELECTRONICS: MIN INPUT VOLTAGE. 8 VDC LG330N1C-A5. 330 W MAX INPUT VOLTAGE. 60 VDC303.9422528 OPEN CIRCUIT VOLTAGE. 40.9 V MAX INPUT ISC 11 ADC DESIGNER: MAX POWER VOLTAGE. 33.7 V MAX OUTPUT CURRENT 15 ADC ANDREW HOFFMAN SHORT CIRCUIT CURRENT 10.45 A DRAFTER: SYSTEM CHARACTERISTICS-INVERTER 1 DIMENSION I SYSTEM SIZE. 6930 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE. 13 V ELECTRICAL SYSTEM OPERATING VOLTAGE. 3V 80 MAX ALLOWABLE DC VOLTAGE. 480 V SYSTEM OPERATING CURRENT 18.2 A REV Al 10/12/2017 SYSTEM SHORT CIRCUIT CURRENT 30A PAGE PV-4.0 System Information 6.93 kW DC Photovoltaic System (21)LG Electronics:LG330N1C-A5,SclarEdge Technologies:SE8000H-USRGM Allowable Backfeed Allowable Baddeed=(Main Panel Rating)x 1.2-(Main Brooker Rating)_ 200A x 1.2-200A=40A 35A s 40A-.Interconnection meals 705.12(D)(2)requirements. DC Wre Sizing Max Circuit Current=(Opl)m)zer Max Power)x(Continuous Load)[690.8(B)(1)]_ 15A x 1.25=18.75A Adjusted Conductor Ampecily=(High Temp)[Table 310.16]x(Conduit Fill)(Table 310.15(13)(2)(s)]x(Conductor Ampacity)[fable 310.16]_ 0.76 x 0.8 x 40A=24.32A Terminal Rating[110.14(C)]_ 10 AWG,60'C Rated=30A 24.32A<30A—Adjusted conductor ampacily governs conductor sizing. 18.75A<24.32A—10 AWG Ampacity,OK Therefore 10 AWG is sulficient. AC Wire Sizing /SOF NE Max AC Output Current=(Max Inverter Output)x(Contxuuow Lood)[210.19(A)(1)1= y�yi d0 AA�N�Ct 25 A x 1.25=31.26 A ¢ 1 * p F Adjusted Conductor Ampaeity=(High Temp)[Tabk 310.18]x(Conduit Filh[Tabk 310.15(8)(2)(a)]x(Conductor Ampacity)[Tabk 310.181 q 1 T 0.96 x 1 x 55A=52.8A 2, Terminal Rating[110.14(C)1= 8 AWG,601C Rated=40A \ ` 40A<52.8A-+ Terminal rating governs conductor sing. FO E08)693 31.25A<40A 8 AWG Ampacrty OK \°H ' Therefore 8 AWG is sufficient. `SS 1O� Inverter Overasrent Protection (Inverter Max Current)x(Continuous Load)= s u n r u n 25 A x 1.25=31.25 A 35 A Overwrrent Protection System Characteristics VMP =Inverter Fuad String Voltage= 350V 54139-MEVOC =Max Inverter System Voltage= 500V s awn n �v6 a wiuE n no Operating Current =(OC System Size)/350V= P°ura06Di08� 6930W/350V =19.8 A c�a�awaa Short Circuit Current=(Optimizer Max Current)x(N Strings) 15A x 2=30A CUSTOMER RESIDENCE. VICTOR PEREZ 2780 BOISSEAU AVE, SOUTHOLD,NY,11971 TEL QPM)mxi-ns APn 0 100075S000I000ta11011 PROJECT NUMBER: 211R-780PERE DESIGNER: 303.9422528 Assumptions: ANDREW HOFFMAN Max Ambient Temperature =32°C DD RAFTER I Low Temperature=-17°C All conductors are 90°C rated copper SHEET ELECTRICAL Roof top temperature adder=22°C CALCS Attic temperature adder=7°C REV'A.1 10/122017 PAGE 1V-4.1 7� INVERTER 1 NOTES AND SPECIFICATIONS: ' BELS SFIRLL MEET THE REOUREMENTIS OF THE NEC 2017 A B) PHOTOVOLTAIC • • / PHOTOVOLTAIC• • • •SIGNSAND11021(9),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY 16.2 SECTION 660,OR IF REQUESTED BY THE LOCAL AW. • • D SOURCE 360 •SIGNS AND LABELS SWILL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE ELECTRICAL SHOCK HAZARD ,69 WORDS.COLORS AND SYMBOLS. •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRM LABEL LOCATION: 30 METHOD AND SHALL NOT BE KUM WRITTEN. DO NOT TOUCH TERMINALS. INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,AT EACH TURN,ABOVE AND •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT BELOW PENETRATIONS,ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. LABEL LOCATION: INVOLVED. TERMINALS ON LINE AND LOAD PER CODE(S):CEC 2016:69031(0)(3),69631(0x4),NEC 2014:69031(0)(3), INVERTER(S),OC DW"OECT(S). •SONS AND LABELS SHALL COMPLY WITH ANSI 25354 2011,PRODUCT SAFETY 69031(0)(4),NEC 2011:69031(E)(3),66031(E)(4),IFC 2012:605.11.1 A PER CODE(S)CEC 2016:680.63.NEC 20169 4 053,NEC SONS AND LABELS,UNLESS OTHERWISE SPECIFIED. SIDES MAY BE ENERGIZED IN 201166053 •00 NOT COVER EXISTING MANUFACTURER LABELS. THE OPEN POSITION I PHOTOVOLTAIC LABEL LOCATION. EQUIPPED INVERTER(S),AC DISCONNECT(S),AC COMBINER PANEL (IF APPLICABLE). WI TH PER COOE(S):CEC 2016:800.17(E),NEC 2014:690.17(E), RAPID ,• NEC 2011:690.17(4) WN LABEL LOCATION: I UTILITY SERVICE ENTRANCEIMETER,INVERTERIDC DISCONNECT IF REQUIRED BY LOCAL AW,OR OF Ne OTHER LOCATIONS AS REQUIRED BY LOCAL AW. 'P ^O M( rO ELECTRICAL SHOCK HAZARD NEEc�.s($FC20122100511.1 NEC 2014*690.12' �co � Nc�9� �!* Q- IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED PHOTOVOLTAIC AC DISCONNECT CONDUCTORS MAY BE "40 VA UNGROUNDED AND ENERGIZED 9�SSQO LABEL LOCATION: LABEL LOCATION: AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INVERTER(S),ENPHASE ENVOY ENCLOSURE(IF INTERCONNECTION. s u n r u n APPLICABLE). PER CODECS):CEC 2010:090.54, 69 4,NEC 2014: 054,NEC PER COOE(S):CEC 2010:69G5(C),NEC 2014:0605(Q, 2011:69051 NEC 2011.6905(C) BUILDING SUPPLIED BY UTILITY 54139-ME ELECTRICAL SHOCK HAZARD DUAL POWER SUPPLY GRID AND PHOTOVOLTAIC THE DC 15CWAIOTTEAV lf.'ANIUSAA'— CONDUCTORS THIS SOURCES:UTILITY GRID v oA Naeoan PHOTOVOLTAIC SYSTEM ARE AND PV SOLAR ELECTRIC SYSTEM UNGROUNDED AND MAY BE ENERGIZED SYSTEM Q CUSTOMER RESIDENCE. LABEL LOCATION: LABEL LOCATION: VICTOR PEREZ INVERTER(S),DC DISCONNECTS. UTILITY SERVICE METER AND MAIN 2780 BO ISSEAU AVE, PER CODE(S):CEC 2016 69035(F),NEC SERVICE PANEL. SOUTHOLD,NY,11971 2014:69035(F),NEC 2011 86035(F) PER CODE(S):CEC 2016:705.12(1))(3). NEC 2014:705.12(D)(3),NEC 2011 TEL M31)n•-77WANN•ta000e6000eoo0tcow 705.12(D)(4) PROJECT NUMBER: 211R-78OPERE TDONOT U7PUTCOINECTIDN pHOTOVOLTAICSYSTEM DESIGNER: 309.9422528 RELOCATE THIS COMBINER PANEL ANDREW HOFFMAN URRENT DEVICE DO NOT LOADS DRAFTER: LABEL LOCATION: LABEL LOCATION: DIMENSION I ADJACENT TO PV BREAKER OF PHOTOVOLTAIC AC COMBINER(IF APPLICABLE). APPLICABLE). PV SYSTEM SHEET PER CODE(S):CEC 2016: PER CODE(S)'CEC 2016: DISCONNECT SIGNAGE 705.12(D)MO)(b),NEC 2014 705.12(D)(2)(9)(e),NEC 2014: 705.12(13)(2)(3)(b),NEC 2011 7115.12(0x7) M.12(D)m(3)(c).NEC 2011.705.12(D)(4) LABEL LOCATIOW REV'A.1 10/122017 PONTOF INTERCONNECTION (PER COOE NEC690.50(B),NEC705.10.225.37 270](E)) PAGE PV i C.0 LG Innovation for Life's Good a Better Life LG NeN 2 LG's new rriodule,LG NeONT"2,adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires /� to enhance(tower output and reliability.LG NeCINT"A 2 DVE ; 1 I cell, demonstrates LG's efforts Lo increase customers values I„rertek Cc iJ V beyond efficiency,It features enhanced warranty,durability, performance under real environment,and aesthetic design suitable for roofs. Enhanced Performance Warranty , High Power Output LG NeONTti"2 has an enhanced performance warranty. Compared with p€ev€ous models,the.LG NeONT'2 The annual degradation has rallen from-0.61r<Jyr to has been resigned to significantly enhance its output Even after 25 years,the cell guarantees 1.2'%p efficiency,thereby making it efficient even in limited space more uu,put than the pray€ous LG NeONJ 2 modules AM Aesthetic Roof Outstanding Durability LG NeONT"2 has been designed wiO)aesthet€cs in mind" With its newly reinforced'came design,LG has extended thinner tires that appear all black at a distance the warranty of trip LIS NecONT'2 for an additional 1 hc product may help Increase the value of years.Additionally,LG NeON"'2 can endure a front a property;with its incidern des!y.!, load up to 6000 Pa and a rear load up to 5400 Pa. Better Performance on a Sunny Day Double-Sided Cell Structure ♦ LG NeONT^2 now performs better on sunny clays thanks The rear of Che cell used in LG NpONT"2 will to to rt,,improved temperature coeffic ency. generation,Just like the trout:the light bean reflected from L the mar of the mode€e is reabsorbed to generate a great amount of addil€onal uovrer. About LG Electronics LG Eiertronics!s a Qioba! player Mn ha:Leen cto e,pa d nj y ;sed cw volar energy bu,rne5s as. ^,no "O.tr*onq;ne AI,_ on,: ..:a'energy:Dore r_•L,rrh prog:am 1985,suppu!teG by L GP)upSri.ri eXrl I!e:.e:(iie!!TI-':'mdrl'Tnr LCD(hem'str•fa!r:d.rt.iLP('yi,:nii L15`.I'y VVN iUcies"fuflycelea"'d the fire:fvlorc X1,cr:,. tc't,i,'rna,,et.n.,'U'0 Ah:cf we re e Kpute:.t:,52 (r,unt;:vs n+hf- 9 years,thr-rer(ter In 2J z I G.''()V';p:t••ali";s;;"Lrn:ar r,M,nu%°far.Nd v.nn irnei-Lir A*,i t vd;':.:r pr,.v­i Lam, tr"i-dt-r.n1 r:n1;1.at!oo 19 the Ir:nut.I p. LG NeON z EMM Mechanical Properties Electrical Properties(STC*) Celts 6 x 10 Module LG330N1C-A5 Ceti Vendor LG Maximum Power(Pmax) 330 Ceti Type Monoc.rysta ne./€V-type MPP Voltage(Vmpp) 337 Ceti Dimensions 61 7 x 161 7 mm/6 inches MPP Current(Impp) 9.8 R of Busbar 12(ML-tiWire Bulbar) Open Circuit Voltage(Voc) 4.0.9 Dimensions(L x W x H) 1686 x 1016 x 40 Trim Short Circuit Current(Isc) 66.38 x 40 x .57 ir.,'i Module Efficiency 19.3 Front toad 60001'a Operating Temperature -40-+90 Rear Load 540UPa Maximum System Voltage 1,000 Weight 8 Lg Maximum Series Fuse Rating 20 Connector Type MC4 Power Tolerance(%) U +3 Junction Box IP68 wit l 3;Bypass Diodes <,i: v r::a,c.x::bo-. irr::;:a::-..•i oon..,m nr r„::f*. ",T,. :.;r I Apr Cables "000 mrr:x 2 ea 'r'e::.•:,ef:.ae p.wr.,�,-her .t..i,i:.d a"::r drrF,i-::n<r fn t;Efr:r;,nf;-.a-rt} ol,•.a.d ao.,r:::•:•d:,o•r.� -- — — — — — _- — — — — __ _ '?f:P.IY{=t::Ci,.I::�FI^1":.a l':i^Ff'.�.nC;.t l.::r::in i. ..l.lC , , ,IT),• I.ti'h. Glass Higli'''ransm:ssion 7emperetl Glass Frame Anodi rerl At.nminiurn Electrical Properties(NOCT*) Certifications and Warranty Module LG330N 1 C-AS Certifications iEC 612 5,IEC:61 7 30-1/-2 Maximum Power(Pmax) 243 :it."-703 MPP Voltage(Vmpp) — — 31.2 - 'EC 61 701(Salt mist corm,ir n test) MPP Current(Impp) 7II IFC 62716(Anima)ma corrosion test) Open Circuit Voltage(Voc) 38.1: 150 900 Short Circuit Current(Isc) 3.r+ Module Fire Performance(USA) ype I 'N0,";14,:ff r;:,f nq,'>a re F::•.•,:.:e;Ined:.,.resrr;W,nr ar,h,- e•,,-r f:,fr 20-t ,.,f,e,p.d;,:: Fire Rating(CANADA) CI•,55(';U C/0?D C.7031 Product Warranty '2v ars Output Warranty of Pmax Linear warranty" Dimensions(mm/in) .�� �.r J,"... .,2-,ftr <:tl,.':E'�t ,._`rl:•nf:d:�z.irl3t;: 3i.. _.il� 2:.1.,,, -- -_ Temperature Characteristics NOCT 45±3'r Pmpp ')37%'C Voc 0.;7;;'C Isc 0.03:%;"i Characteristic Curves n I 000 800w 400W 20OW 4 I I LG :;'-'r Bu•,n•s'r,af r r:od;:-isle fh,au.;m b; °U. harrP,,-'I,n:not rr o e:t,_t: f. U ss,.int Life's Gond H000 Cylaan Ave,Engiewoc^.Glffs.•�!;u76:2 1111 r,,pj-igl•t: 'LG;Ie,'. Alt!w1ht,rrsr,:ed Innovation for aBetter Life Contacr'OsoL;r`JI:1.a:r.. - ,...+,lyo:a:.fsa�or.� ^ solar=ee z SolarEdge Single Phase Inverters For North America or i;jao The best choice for SolarEdge enabled systems - Integrated arc fault protection for NEC ZU11OgO11compliance - Rapid shutdown for NEC 2014 690.12 - Superior efficiency(98Y6) - Small,lightweight and easy toinstall onprovided bracket — Bui|t-inmodule-level monitoring — Internet connection through Ethernet orWireless — Outdoor and indoor installation - Fixed voltage inverter,DC/AC conversion only � Pre-assembled Safety Switch for faster installation � Optional—revenue grade data,ANSI Cl2.l solar=ee Single Phase Inverters for North America SE300OA-US/SE380OA-US/SE500OA-USfSE600OA-USi SE760OA-US r`SE10000A-US/SE1140OA-US SE3000A-US SE380OA-US SESOOOA-US SE600OA-US SE760OA-US SE1000OA-US SE114GOA-US OUTPUT Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA 1000Q @240V Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10306 @ 208V 12000 VA 5450 @240V 10950 @240V AC Output Voltage Min.-Nom:Max.-' 183 208 229 Vac f AC Output Voltage Min.-Nom.-Max." V f ✓ 211-240-264 Vac AC Frequency Min:Nom.-Max.{" 59.3-60-60.5 N7 Max.Continuous Output Current 12.5 16 24 @ 208V 25 32 48 @ 208V 47.5 A 21 @ 240V 42 C 240V GFDI Threshold 1 A Utility Monitoring,Isla nding_Pro_tection,Country Configurable Thresholds Yes Yes INPUT Maximum DC Power(STC) 4050 5100 6750 8100 10250 13500 15350 W Transformer-less,Ungrounded Yes Max.Input Voltage 500 Vdc Nom.DC Input Voltage 325 @ 208V/3S0 @ 240V Vdc Max.Input Current`" 9S 13 16.5 @ 208V 1.8 23 33 @ 208V 34.5 Adc 155 @ 240V 30.5 @ 240V Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k,Sensitivity Maximum Inverter Efficiency 977 98.2 98.3 98.3 98 98 98 % 97 @ 208V 97 a 208V CEC Weighted Efficiency 97.5 98 98 @ 240V 97.5 97.5 97.5 @ 240V 3T5 °k Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces R5485,RS232,Ethernet,ZigBee(optional) Revenue Grade Data,ANSI 012.1 Optional', Rapid Shutdown—NEC 2014 690 12 Yes STANDARD COMPLIANCE Safety UL1741,UL1699B,UL1998,CSA 22.2 Grid Connection Standards IEEE1547 Emissions FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4"minimum/16-6 AWG 3/4"minimum J 8-3 AWG DC input conduit size/#of strings( 3/4"minimum/1-3 strings/ 3%4"minimum/1-2 strings/16-6 AWG AWG range '14-6 AWG Dimensions with Safety Switch 30S x 12.5 x 10.5 J in/ (HxWXD) 30.5x12.5x7.2J775x315x184 775x 315x260 mm Weight with Safety Switch 51.21 23.2 S47/247 88 4/40.1 Ib/kg Natural convection Cooling Natural Convection and internal Fans(user replaceable) fan(user replaceable) Noise <25 <50 dBA Min.-Max.Operating Temperature 13 to+14011 25 to+60(-40 to+60 version available") -F/"C Range Protection Rating NEMA 3R For other regional settings please contact SolarEdec support 'A h:gi er current source may be used,the inverter will tint its Input current to the values states "Revenue grade inverter P/N SFUX A-LISOOONNR7(for 7600W inv=rter'SF76f.ICA-US�O2N:'JR2). -40 versio-i PIN 5F..uA-USX,0NNU4(for 760OW a+verter:SF7600i-USO02NNU4). `SiJf:SPE:: RoHS Snap , rack- Solar Mounting Solutions Series 100 Residential Roof Mount System The SnapNrack Series 100 Roof Mount System is engineered to optimize material use, labor resources and aesthetic appeal, This innovative system simplifies the process of installing solar modules, shortens installation times, and lowers installation costs; maximizing productivity and profits. The Series 100 Roof Mount System boasts unique, pre-assembled, stainless steel "Snap- In" hardware and watertight flash attachments. This system is installed with a single tool. No cutting or drilling means less rail waste. It is fully integrated with built-in wire management, solutions for all roof types, one-size-fits-all features, and can withstand extreme environmental conditions. Series 100 is listed to UL Standard 2703 for Grounding/Bonding, Fire Classification and Mechanical Loading. UL 2703 Certification and Compliance ensures that SnapNrack installers can continue to provide the best in class installations in quality, safety and efficiency. • Appealing design with built-in aesthetics • No grounding lugs required for modules • All bonding hardware is fully integrated 4P Rail splices bond rails together, no rail jumpers required yx • No drilling of rail or reaching for other tools ............... required �y, ... . ........ 0 Class A Fire Rating for Type 1 and 2 modules System Features Include Snap in Single Tool Easy No Cutting Hardware Installation Leveling or Drilling O Integrated Wire Preassembled Integrated bonding UL 2703 Certified Management hardware Resources snalonrack.conn/resources Design snapnrack.com/configurator Where to Buy snapnrack.corn/where-to-buy Snap rack- Solar Mounting Solutions Stainless Bolt with Stainless Steel ,—Bonding Splice Standard Rail Split-Lock Washer Bolt with Split- Insert 015-09816 Lock Washer Bonding Adjustable End Clamp Top Bonding Splice _ Mid Clamp Base �- ing Bonding Adjustable —Bonding ;- Channel Nut End Clamp Bottom Channel Nut IStainle's."-,LStainless Hardware with Split-Lock Washers Split Lock ' Bonding Adjustable Bonding Mid Clamp Bonding Standard Washer End Clamp 242-02062 242-02053 Rail Splice Ground Lug J 242- ms 242-02101 12-6 AWG— Copper Wire Ground Lug Assembly (ONE REQUIRED PER ROW OF MODULES) Universal End Clamp(UEC) Wave —UEC Pull Strap 7cow—.dge Stainless Steel Bolt»_.. with Flat Washer Universal End Clamp 242-02215 Standoff Clamp Assembly Rubber- Serrated Stainless_� -Channel Channel Nut Rain Collar Steel Flange Nut Nut \ Stainless Serrated Stainless Flange Nut Mill Finish_ Steel Flange Bolt 92 Degree 0 Stainless Standoff L Foot Flange Bolt -All Purpose L Foot Mill Finish Standoff ��- Base(1-Hole L Foot Metal Roof Ailiijl Base Shown) w Mill Finish- - Base Assembly L Foot Base Flashing Metal Roof Base Standoff J L L Foot Base with Flashing j with L Foot 242-92057 242-92050 242-02037 SERIES 100 TECHNICAL DATAI •6000 Series aluminum Materials • Stainless steel . Galvanized steel and aluminum flashing - Silver and black anodized aluminum - Mill finish on select products Material Finish • Silver or black coated hardware Note.Appearance of mill finish products may vary and change over time. Wind Loads 110-190 mph (ASCE 7-10) Snow Loads 0- 120 psf Array Pitch 0-60 degrees 877-732-2860 www.snapnrack.com contact@snapnrack.com r 2016 by SnapNrack Solar Nountung Solutions.All rights reServeci Sna,,Wad$fried 00-&-hure-2.1