Loading...
HomeMy WebLinkAbout42135-Z �o,,pSU '�to� Town of Southold 1/8/2018 0 a P.O.Box 1179 w 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39431 Date: 1/8/2018 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 590 Elijahs Ln, Mattituck SCTM#: 473889 Sec/Block/Lot: 108.-3-5.8 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/31/2017 pursuant to which Building Permit No. 42135 dated 11/13/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels on existing one family dwelling as applied for. The certificate is issued to Guvenc,Berna of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 42135 12/20/2017 PLUMBERS CERTIFICATION DATED Authorized Signature 04T TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE o . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 42135 Date: 11/13/2017 Permission is hereby granted to: Guvenc, Berna 590 Elijahs Ln Mattituck, NY 11952 To: install roof-mounted solar panels as applied for. At premises located at: 590 Elijahs Ln, Mattituck SCTM # 473889 Sec/Block/Lot# 108.-3-5.8 Pursuant to application dated 10/31/2017 and approved by the Building Inspector. To expire on 5/15/2019. Fees: SOLAR PANELS $50.00 CO -ALTERATION TO DWELLING $50.00 Total: $100.00 B ilding Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial $15.0`01 Daty' New Construction: Old or Pre-existing Building: V (check one) Location of Propel 1� I t J l� Mcg, 6k House No. Street Hamlet Owner or Owners of Propert-yJ !�`�(1^(1 LA Suffolk County Tax Map No 1000, Section 09 Block Lot .5,1R Subdivision otl TUC Filed Map. Lots:{ Permit No. Date of Permit. Applicant: 1-04 Health Dept. Approval: Underwriters Approval: Planning Board Approval,: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ a e4wlo Applicant Signature Town Hall Annex Telephone(631)765-1802 54375 Main Road Q Fax(631)765-9502 P.O.Box 1179 G (a� roger.richerttown.southold.ny.us Southold,NY 11971-0959 BUELDI NG DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Guvenc Address: 590 Elijahs Lane city,Mattituck st: New York zip: 11952 Building Permit#: 42135 Section: 108 Block: 3 Lot: 1 5.8 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Momentum Solar License No: 37608-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency FixtureTime Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: 8.265 KW Roof Mounted Photovoltaic System to Include; 29-285 Panels with Micro Inverters, Rapid Shut Down, Solar Meter. Notes: Inspector Signature: Date: December 20, 2017 0-Cert Electrical Compliance Form.xls SOUIyO{o �coutm,� _ 1 " TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH.PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) KELECTRICAL (FINAL) REMARKS: DATE INSPECTOR r y ` { momentum SOLAR December 22, 2017 Town of Southold Building Department 54375 Route 25 P.O. Box 1179 Southold,NY 11971 Subject: Architect Statement for Solar Roof Installation Residence: Berna Guvenc-590 Elijahs Lane,Mattituck,,NY-11952 Permit No. 42135 Post Installation Inspection Date: 12/22/17 The roof mounted photovoltaic system at the above referenced residence has been observed to be , installed properly in accordance with the approved plans and is certified by Daniel W Dunzik Architectural Services, P.C. to be in compliance with the minimum requirements of the Town, the 2015-International Residential Code and the 2016-New York State Uniform Code Supplement and the Provisions of ASCE 7-10. e° DU C C C DSC h JAN 8 2010 Q39536 Dar y TOWN O-'SOUTRO LD ReRkt-i i ect 325 High Street D:732.902.6224 Metuchen,New Jersey F:732.902.6223 o8840 W:momentumsolar.com FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) _ ------------------------------- FOUNDATION (2ND) z lTl � ROUGH FRAMING& H PLUMBING to clq r r� INSULATION PER N.Y: y STATE ENERGY CODE FINAL ADDITIONAL COMMENTS �7 ra UIL qla-M 11114DI 32-ft G Z m 1-3-I Zlt- U1 y 1 d b y r TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX:(631)765-9502 Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Pemut Examined 20 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved 20 Mail to: Disapproved a/ ---]C= I Phone: Expiration 20 ding s or _ APPLICATION FOR-i ILDING PERMIT j Date /0 3 20_L7 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or j areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector i issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the j property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections a (Signature of applicant or name,if a corporation) 45 Fairchild Ave.Suite B.Plainview,NY 11803 (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder r ntmr-tor Name of owner of premises e f no, GV V n (As on the tax roll or latest deed) If applicant is a co on,signs dulyauthorized officer (Name and title of corpora a officer) Builders License No. 576]� —14 Plumbers License No. IV /— Electricians License No. 37608-ME Other Trade's License No. 1. Location of lan whi h proposed work will be done: 5q b 17= ►� P Nhe , M� House Number t4 Street Hamlet County Tax Map No. 1000 Section I U a Block 3 Lot • ; Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and int ed use and occ pancy f pro osed co struction: a. Existing use and occupancy On r \1 y ��� z1as a�C�y! b. Intended use and occupancy 1651 ci) q R04 Of f0WyD S /U/1 P01V/S 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work Sol a r Pg A e I S 4. Estimated Cost (Description) 4 o�3 I M-70 Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district to which premises are situated 12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO 13.Will lot be re-graded?YES_NO—Will excess fill be removed from premises?YES NO- .6,q0 'F#;qhs Gn. 14.Names of Owner of premises berAof 6-W 211C Address/44W/Vck*111la Phone No. &3I"315–5,09 y Name of Architect Daniel W Dunzik Address sW°B;–`��X58 Phone No 08-872-3664 Name of Contractor 6-7m eros Chl'iSf e n s Qtl Address 45 Fa-rchi l Ave,fbi Phone No. 63I`5 6'41 DD t4101803 –svl�e ` / 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO x *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO *IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS. COUNTY OF SUFFOI K) Y N Cameron Christensen being duly sworn,deposes and says that(s)he is the applicant O N (Name of individual signing contract)above named, } ^ JW W (S)He is the Contractor LL LL�0 0 a (Contractor,Agent,Corporate Officer,etc.) CO Z 0 ti Y Zi W QLU PMOw of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; Q L a that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be tY W M co X performed in the manner set forth in the application filed therewith. vJ U o z Z Q� 00O Sworn to before me this 00 D z w oC3r� day of bc�ober 20 1_� __ LL Co H a! j C70 Notary Public Signature of Applicant z P\,eAc- e. ?czv; A4 5�6kA `' 15 - Of SO(/Tyol , 0 Town Hall Annex 4 Telephone(631)765-1802 54375 Main Road c/) m�ax(631)765- 5Q� P.O.Box 1179 �, Q roger.richert(cytown_sout�0 nV us Southold,NY 11971-0959 COY I • BUILDING DEPARTMENT 'DOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY. N Date: Company Narrl,e: Morn I ' Name: m - License No.: Address: Phone No.: _ 16 �= JOBSITE INFORMATION: (*Indicates required information) *Name: ,r OL 6(Avenc *Address: 5 ' O-A 5 *Cross Street: a r? 1 R G a 'Phone No.. (3) - �15 - 5o9 4 i Permit No.: I- Tax-Map District: 1000 Section: _ Block:_ Lot: J *BRIEF DESCRIPTION OF WORK(Please Print Clearly) 1n C1 41"m C j (Please Circle All That Apply) *Is job ready for inspection: j YES/dg> Rough in Final I *6o' you need a Temp Certificate: CESNO ' _ I Temp Information (If needed) ' *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other I . *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION a , I - 82-Request forinspection Form 1 1 OF SOUj�®l � o Town Hall Annex Telephone(631)765-1802 54375 Main Road N Fax(631)765-9502 P.O.Box 1179 G • Southold,NY 11971-0959 �O a December 27, 2017 BUILDING DEPARTMENT TOWN OF SOUTHOLD Momentum Solar 45 Fairchild Ave Plainview, NY 11803 Re: Guvenc, 590 Elijahs Lane, Mattituck TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: NOTE: Post Installation Certification required stating panels were installed per NYS 13,7ng Code Application for Certificate of Occupancy. (Enclosed) r �. Electrical Underwriters Certificate. A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1184) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 42135 —Solar Panels AlIENTION 14OMF—IMP-RO-VEMENT-CONTRA-CT-ORS Suffolk Coupfy QOft-Chanter-563-17(D) 05 N—HOME IMPROVEMENT SALESPERSO SUFFOLK COUCONSUMER AFFAIRNTY DEPT OF-LABOR, LICENSING& S LICENSEE HOME IMPROVEMENT Name:CAMERON CHRISTENSEN CONTRACTOR -LICEN$E License 4-.2042829-DCA HAW CAMERON CHRISTENSON Expiration Date;Feb 23,2017 -4 , This certifies that the BMWESUNAME �s W bearer is duly PRO CUSTOM SOLAR LLC DBA licensed by the cORS""" *11709-2016-AFIS* 0106/2016 County of Suffolk """"`a" 71111- 57578-H 116 � t vORK Workers' CERTIFICATE OF ATE Compensation Board NYS WORKERS'COMPENSATION INSURANCE COVERAGE 1 a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Pro Custom Solar LLC 732-902-6224 DBA Momentum Solar 45 Fairchild Avenue,Suite B Plainview,NY 11803 1c.NYS Unemployment Insurance Employer Registration Number of Insured Work Location of Insured(Only required if coverage is specifically limited to id.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,Le„a Wrap-Up Policy) Number 271-24-2539 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) New York Marine&General Insurance Co. Town of Southold South Route 25 11 3b.Poli Number of Entity Listed in Box"la" Southold,NY 11971 Policy Y WC201600012773 3c.Policy effective period 12/12/2016 to 12/1212017 3d.The Proprietor,Partners or Executive Officers are D included.(Only check box if all partners/officers included) ❑ all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". Will the carrier notify the certificate holder within 10 days of a policy being cancelled for non-payment of premium or within 30 days if cancelled for any other reason or if the insured is otherwise eliminated from the coverage indicated on this certificate prior to the end of the policy effective period? E]YES ENO This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or after the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business Is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Christine Howley Approved by n (Print name ofV$Ialive or licensed agent of insurance carrier) I - -, I blu :] I S) I -�, (Signal ( te) Title:Program Manager Telephone Number of authorized representative or licensed agent of insurance carder- 973-532-1900 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it C-105.2(9-15) www.wcb.ny.gov PDF created with pdfFactory trial version www.pdffactory.com Workers' Compensation Law Section 57. Restriction on issue of permits and the entering into contracts unless compensation is secured. 1. The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter, and notwithstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that compensation for all employees has been secured as provided by this chapter. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any compensation to any such employee if so employed. 2. The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or In connection with any work involving the employment of employees in a hazardous employment defined by this chapter,notwithstanding any general or special statute requiring or authorizing any such contract,shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that compensation for all employees has been secured as provided by this chapter. 1 r C-105.2(9-15)REVERSE PDF created with pdfFactory trial version www.pdffactorv,.com PROCU-1 OP ID: LM '4�RAW CERTIFICATE OF LIABILITY INSURANCE DATE(M5/20 05/25/20 7 17 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTNAMEACT Lisa MacDonald Brown&Brown Insurance PHONE 732-504-2001 (FAAX 1C 732-504-2011 2000 Midlantic Dr.-Suite 440 AIC No Et): AIC No Mount Laurel,NJ 08054 E-MAIL Brian DiLuigi SS:Imacdonald@bbdvins.com INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:New York Marine&Gen Ins Co 16608 ,INSURED Pro Custom Solar LLC INSURER B:Lloyd's DBA Momentum Solar 45 Fairchild Avenue,Suite B INSURERC:Hiscox Insurance Company Inc 10200 Plainview,NY 11803 INSURER D: INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCEADDLSUBR POLICY EFF POLICY EXP LTR INSD WVD POLICYNUMBER MM/DD MM/DDIYYYY LIMITS B X COMMERCIAL GENERAL LIABILITY I EACH OCCURRENCE $ 1,000,000 CLAIMS MADE ®OCCUR GL201600007987 12!1212016 12/1212017 PREMISES Ea occurrence $ 100,000 C ANE1860007.16 12/01/2016 12/01/2017 MED EXP(Any one person) $ 5,000 X Professional Liab CLAIMS MADE PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 2,000,000 POLICY PRO- JECT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER* PROF $ 1,000,000 AUTOMOBILE LIABILITYCOMBINED SINGLE LIMIT Ea accident $ 1,000,000 A X ANY AUTO AU201700012651 04/21/2017 04/21/2018 BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY Per accident $ AUTOS AUTOS ( ) X HIRED AUTOS X NON-OWNED PROPERTY DAMAGE $ AUTOS Per accident X UMBRELLA LWB OCCUR EACH OCCURRENCE $ 5,000,000 B EXCESS LIAB HCLAIMS-MADE UM201600004884 12/1212016 12/12/2017 AGGREGATE $ 5,000,000 DED RETENTION$ $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY X STATUTE ER A ANY OFFICER/MEM ER EXC NERIEDEI ECUTIVE Y®N f A WC201600012773 121121201;6 12!1212017 E L EACH ACCIDENT $ 1,000,000 (Mandatory in NH) E L DISEASE-EA EMPLOYEE $ 1,000,000 If Yes,descnbe under DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 53095 Middle Road ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD Daniel W. Dunzik Architect LEED-AP Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd.Skillman, NJ.08558 908-872-3664 370 Burnt Hill Rd.Skillman, NJ.08558 908-872-3664 October 20, 2017 panels shall be designed to support in excess of 30 lb. snow load by the manufacturer. Solar panels do not add any additional snow load to the existing structure. Refer to manufacturers Township of Southold specifications. 53095 Route 25 Southold,NY 11971 4. All penetrations shall be completely water tight and guaranteed for a period of ten years or the duration of the existing roof warrantee whichever is longer. Attn: Construction Official Re: Proposed Photovoltaic Solar Panel Installation 5. Positive drainage of the system shall be provided so as to not void the existing roof Berna Guvenc warrantee. 590 Elijahs Ln. Mattituck NY 11952 6.All attachment system components shall be manufactured by"Eco-Fasten Inc."All Dear Sir: attachment system design is based on manufacturers printed design specifications.All aspects Regarding the solar panel array installation on the above referenced project please note that of this design shall be installed in strict compliance with manufacturers printed specifications. A visual inspection was performed and analysis of the existing structure was conducted.There is adequate structural capacity for the installation of the array with the following 7. All aspects of the installation shall comply with the 2015-International Residential recommendations: Code,the 2016-New York State Uniform Code Supplement,all local Code and ordinances,2014 National Electric Code NFPA 70/2014,Weathering Severe,Wind 1. The array will be installed on the existing roof.The roof is constructed of 2"x6"wood rafters Exposure Category B,Climate Zone 4A. @ 16" O.C. spanning 13' 1"max.up the slope with 2"x4" collar ties @ 48" O.C. and 1/2" _plywood sheathing. The new array(See Site map by contractor)will add 2.63 Lb./Sf. overall If you ha due s relating to this matter,please contact me at your earliest to the roof.No additional structural support is required for the existing roof structure. cone '\ 6 , G �,,EL W oU,y 2. The system shall be secured to the roof using the"Ecolibrium Solar""Eco-X" ®attachment �� �'� CQNqLr'ti�+�ITI� ;�L°� t�C ES OF system. The attachment system shall be UL 1703 approved tested.The attachments shall be �v NEl/iI YORK STATE & TOWN DOGES 1 min. 5/16"x 4" long stainless steel lags with a min. embedment of 2"into the rafters. When ` ' '_ AS REQUIRED W � U � fIOINS mounted in landscape or portrait attachments shall be spaced @ 48" o.c. max.with each row NOLD TOWN 6 staggered in roof wind zone 1. Attachments shall be spaced @ 32"o.c. max. in wind zone 2& -y� Q� - 3. The maximum panel cantilever length shall be 16" in wind zone 1,2, &3 except whenOF NEN; ED-n 1, NNING BOARD mounted in portrait the maximum cantilever length shall be 12"in wind zone 3 only. Provide 6 UAffl -Q11" t S;EES mil. vapor barrier between dissimilar metal fasteners.Provide water tight gasket and sealant at Daniel W. Dunz RA.LEED-AP SQall penetrations. Attachments shall follow panel rows as specified by the system Lic.No. 039534 manufacturer's installation manual. The panel angle shall match the roof slope. Structural Design Loads: A5`P�3��Yr �"tg� � � its`e a gCC�6� C� -Dead Loads= lOpsf(+2.6psf,New Solar Panels)= 12.6psf. DATE: �`'�� B.P.9 Y�"�� Ori 9"� �* UNLAWFUL��p p - Snow Loads=30psf(24.5psf- factored per ASCE 7-10),Climate Zone 4A �" u 6 t i U N LA FU L - *Wind loads= 130mph wind speed Exposure B {zones 1,2&3(+/-)= 13psf; zone 1(-)_- FEE' By. .,,_- - — _ 21.3psf,zone 2(-)=-35.6psf, zone 3 - = 48 s *Wind loads per ASCE 7-10. 35.6 sf, i NOTIFY BUILDIidG DEPP,RTM R E WITHOUT CE TEC TE ( ) - p p (-)—- p 765-1802 8 AM TO 4 PM FOR THE OCCUPANCY zone 3(-)_-48} *Wind loads per ASCE 7-10. OF FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED 3. Solar modules shall be secured to the roof as per the manufacturer's specifications. Solar FOR POURED CONCRETE modules shall be UL-1701 rated or better. Solar Panels and attachment system shall ber 2. ROUGH - FRAMING & PLUMBING designed by the manufacturer to withstand winds in excess of 130 MPH. and 50.0 PSF. Solar 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW RETAIN STORM�{AAPT2RUNOFF36 YORK STATE. NOT RESPONSIBLE FOR FURSOLIA .T TO DESIGN OR CONSTRUCTION ERRORS. OF Th` TOVJI\ 01"D T 1 PLAN KEY SYSTEM INFORMATION PV-1 COVER PAGE MODULE JINKO SOLAR JKM285M-60 momentum PV-1(1) COVER PAGE CONT. INVERTER ENPHASE IQ6-60-2-US SOLAR PV-2 PANEL LAYOUT RACKING ECOLIBRIUM ECO X RAIL-LESS SYSTEM PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR PV-3 LAYOUT DETAIL 325 HIGH STREET,METUCHEN,N3 08840 SYSTEM SIZE (DC) 8.265 KW (732)902-6224 -4 ELECTRICAL MOMENTUMSOLAR.COM PV-5 EQUIPMENT LABELS LOCATION 41.00044649, -72.51054872 STRUCTURAL ENGINEERING GENERAL NOTES: DANIEL W.DUNZIK RA LEED-AP LICENSE k 039534 (908)872-3664 370 BURNT HILL ROAD SYMBOL LEGEND THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS SKILLMAN,NJ 08558 ENGAS SPECIFICATIONS FOR FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-10, IRC 2015 AND NEW ANDINEERING LOAD CALCLUULLAETIONS FOR SOLAR R INSTALLATION SPA S&IND YORK STATE UCS 2016 NEC 2014 AND ALL LOCAL CODES &ORDINANCES. ATTACHMENTS WARNING LOCAL AND VIOLABUILDINGTCODE HEL / COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR MSP MAIN SERVICE PANEL ® CHIMNEY ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A AN 18" WIDE (FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED ALONG AT LEAST LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. SP SUB-PANEL SKYLIGHT ONE SIDE OF THE ROOF ON THE SAME SIDE AS THE SOLAR EQUIPMENT OR ON ANOTHER SIDE OF THE RIDGE THAT DOES NOT HAVE SOLAR EQUIPMENT ON IT. IN ED q ADDITION AN 18" WIDE PATHWAY(FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED cJ�F'R ARC, O UTILITY METER ® VENT FROM AT LEAST ONE EAVE. WvDU���'F AC 1 AC DISCONNECT Q PIPE VENT ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE DC SOLAR EQUIPMENT. °lea uoc UTILITY DISCONNECT G FAN INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. N� LC LOAD CENTER SATELLITE DISH ` 03953A \O WEIGHT OF THE INSTALLED SYSTEM SHALL NOT EXCEED MORE THAN 5-PSF FOR OF NES FNNEMA 3R BOX W/ENVOY-S ® FIRE SETBACKS PHOTOVOLTAIC AND NO MORE THAN 6-PSF FOR RESIDENTIAL SOLAR HOT WATER F SYSTEMS. cB COMBINER BOX GROUND ACCESS,- ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT CUSTOMER INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A INFORMATION �p MODULE -► PITCH DIRECTION PLUMBING PERMIT AND INSPECTION. BERNA GUVENC INVERTER PLACEMENT: 590 EL ,N LANE MATTITUCKNY, 11952 631-315-5094 SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE OF EACH MODULE. JURISTICTION:SUFFOLK BILL OF MATERIALS UTILITY:PSEGLI BUILDING REVIEW NOTE: UTILITY ACCT#:9626543503 MODULES 29 UTILITY METER#: 10410667 TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE ENCLOSED DOCUMENT FOR INVERTERS 29 MINIMUM ACCEPTABLE PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS SPECIFIED PV SYSTEM IN THE BUILDING AND/OR RESIDENTIAL CODE OF THE STATE OF NEW YORK. CLAMP ASSEMBLY 73 INFORMATION THISREVIEW DOES NOT GUARANTEE COMPLIANCE OF THAT CODE. THAT COUPLING ASSEMBLY 34 RESPONSIBILITY IS GUARANTEED UNDER THE SEAL AND SIGNATURE OF THE NEW BONDING CLIP 8 29 MODULES:SYSTEM SIZE(DC 8.265 KW )C):: SOLAR JKM285M-60 YORK LICENSED DESIGN PROFESSIONAL OF RECORD. THAT SEAL AND SIGNATURE HAS BEEN INTERPRETED AS AN ATTESTATION THAT, TO THE BEST OF THE LICENSEE'S SKIRTS 10 29 INVERTERS: ENPHASE IQ6-60-2-US BELIEF AND INFORMATION,THE WORK IN DOCUMENT IS: ENPHASE COMBINER BOX 1 1. ACCURATE 60A FUSIBLE AC DISCONNECT 1 2. CONFORMS WITH GOVERNING CODES APPLICABLE AT THE TIME OF THE PROJECT INFORMATION SUBMISSION. 40A FUSES 2 3. CONFORMS WITH REASONABLE STANDARDS OF PRACTICE AND WITH VIEW TO INITIAL DATE:10/23/2017 DESIGNER:MM THE SAFEGUARDING OF LIFE, HEALTH, PROPERTY AND PUBLIC WELFARE IS THE 125A LINE TAPS 2 REV: DATE: DESIGNER: RESPONSIBILITY OF THE LICENSEE. REV: DATE: DESIGNER: COVER PAGE PV- 1 1. ALL WIND DESIGN CRITERIA ARE FOR GABLE AND HIP RESIDENTIAL ROOFS SEE ATTACHMENT SCHEDULE FOR MAXIMUM CANTILEVER CONSIDERED FROM AN ANGLE OF MIN.9.5' (12)TO MAX.45"(J22)NOT TO EXCEED COUPLING ❑ 30'MEAN ROOF HEIGHT WITH A MIN "LAG BOLT(ASTE A276)STAINLESS STEEL CLAMHMENr momentum ATTA INTO THE RAFTER OR BLOCKING BETWEEN RAFTERS W/MIN. EMBEDMENT OF 3" 2. THIS STRUCTURAL DESIGN REFLECTS STRUCTURAL CONNECTIONS TO THE RAFTE SOLAR JINKO SOLAR JKM285M-60 EXISTING STRUCTURE ONLY. MODULE TO ECO-X LOADING AND CERTIFICATION SOLAR MODUL 285 WATT MODULE PER MECHANICAL LOAD TESTS IAW/ANSI UL2703 CONDUCTED ON BEHALF OF ECOLIBRIUM SOLAR BY TUV RHEELAND REFERENCE FILE L2-ELS150128a REV 1 PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 6 " X 39.05" X 1.5 II ( ) 325 HIGH STREET,METUCHEN,NJ 08840 SEE DATASHEETT 3. ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511 AND IS THE (732)902-6224 RESPONSIBILITY OF THE CONTRACTOR TO FILL ALL HOLES WATER TIGHT. GUTTE MOMENTUMSOLAR.COM 4. "ECO-X"ATTACHMENTS ARE MANUFACTURED BY ECOLIBRIUM SOLAR,ATHENS, STRUCTURAL CLIMATIC & GEOGRAPHIC DESIGN GEORGIA.AND SHALL BE INSTALLED IN STRICT COMPLIANCE WITH ENGINEERING MANUFACTURERS PRINTED INSTRUCTIONS. MINIMUM 6'SPACING TO GUTTER DANIEL W.DUN2IK RA LEED-AP CRITERIA TABLE R301.2(1) ECOLIBRIUM SOLAR ECO-X MOUNTING DETAIL LICENSE n 039534 ECO-X TO RAFTER ATTACHMENT SPACING SCHEDULE ECOLIBRIUM SOLAR ECO X RAIL-LESS MOUNTING SYSTEM (908)872-3664 GROUND SNOW LOAD 30 LBS/SF INTEGRATED WITH FLASHING,COUPLINGS AND ADJUSTABLE 370 SKI BLURNT N,HILL 08558D CLAMP ATTACHMENTS ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND SPEED (MPH) 135 MPH AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ULTIMATE ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE TOPOGRAPHIC EFFECTS g ROOF ZONE 1 &2 ROOF ZONE 3 MAXIMUM SOLAR ARRAY ELEVATION:4.25" COMPLIANCE.WARNING THAT U IS A VIOLATION IONOF O LAW FOR DESIGN ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A WIND MAX.SPAN/MAX. MAX.SPAN/MAX. LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. SPECIAL WIND REGION NO SPEED CANTILEVER CANTILEVER MAXIMUM CLAMP ATTACHMENT SPACING:48" WIND BORNE DEBRIS ZONE 2 (MPH) (INCHES) (INCHES) �iF-D A&C, 115 48"O.C./16"MAX. 32"O.C./12"MAX. W.L) J. SEISMIC DESIGN CATEGORY C125 48"O.C./16"MAX. 32"O.C./12"MAX. COUPLING CLAM CLIMATE ZONE 5A 130 48"O.C./16"MAX. 32"O.C./12"MAX. 140 48"O.C./16"MAX. 24"O.C./10"MAX. SOLID BLOCKING WIND EXPOSURE CATEGORY B BETWEEN JOISTS MAX150 48"O.C./16" 24"O.C./8"MAX. o ' 160 32"O.C./12"MAX. 16"O.C./8"MAX. TABLE REFLECTS ATTACHMENT SPACINGS THAT EXCEED MANUFACTURERS LU SPECIFICATIONS FOR WIND LOADS AS PER ASCE 07-10. RISK CATEGORY II �., o3s53a y0 TOPOGRAPHIC EFFECTS B,C,&D AND ROOF WIND ZONES 1,2,&3. ROOF ZONES 2&3 FASTENER REQUIREMENTS: �F NES ARE WITHIN 36"OF ANY OUTER EDGE,HIP,RIDGE,OR GUTTER LINE FOR STRUCTURES 30'-0" OR LESS MEAN ROOF HEIGHT. TOTAL ARRAY AREA=511.18 SQ FT WIND LOAD:ASCE 10(SEE CALCULATIONS,STRUCTURAL CERTIFICATION)50 PSF MAX TOTAL UPLIFT 50 PSF X 511.18=25558.77 LBS C U STO M E R GUTTER GUTTER INFORMATION ® ® Q ® FASTENER: LAG SCREW SPEC 203.2,8/04:(FLAT WASHERS TO BE USED WITH LAG BOLTS) BERNA GUVENC LU W LAG BOLT WITHDRAWAL VALUE 5/16"DIA.,266 LB/IN X 2-INCH THREAD DEPTH: 590 ELIJAHS LANE ® O 532LB.CAP.EACH MATTITUCK,NY,11952 © �Q ® MINIMUM NUMBER OF LAG BOLTS REQUIRED:25558.77 LBS/532 LBS/LAG BOLT=49 631-315-5094 'r MAXIMUM SPAN BETWEEN MOUNTING FEET BOLTS"X"USE 48"MAX ALLOWED AS ® ® RIDGE RIDGE ® ® PERSCHEDULE © ® O ©© © ® JURISTICTION:SUFFOLK 'Silo STRUCTURAL STATEMENT: UTILITY:PSEGLI w UTILITY ACCT#:9626543503 ® D © THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE UTILITY METER#: 10410667 NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE ® O GUTTER ® GUTTER 0 SYSTEM INCLUDING UPLIFT&SHEAR.EXISTING RAFTER PV SYSTEM SIZES &DIMENSIONS CONFIRM TO IRC-2015 TABLE INFORMATION R802.5(1)-RAFTER SPANS. SYSTEM SIZE(DC):8.265 KW ROOF WIND ZONES AS PER IRC R301.2(7) 29 MODULES:JINKO SOLAR JKM285M-60 ROOF ZONES 2&3 ARE 36"FROM GUTTER ROOF EDGES, MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED NEW YORK STATE CODE REQUIREMENTS FOR THE DESIGN 29 INVERTERS:ENPHASE IQ6-60-2-US RIDGES,HIPS, RAKES,AND GUTTER EDGES FOR STRUCTURES CRITERIA OF THE TOWN. BELOW 30'-0"MEAN ROOF HT. PROJECT INFORMATION INITIAL DATE:10/23/2017 DESIGNER:MM REV: DATE: DESIGNER: REV: DATE: DESIGNER: COVER PAGE PV- 1 ( 2 SCALE'• 1/8" = V-O" ROOF MODULE COUNT TILT AZIMUTH SHADING R1 12 18° 52° 12% R2 17 18' 232° 17% momentum SOLAR ° ° d d FIRE SETBACK PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 4 325 HIGH STREET,METNJ 08840 ° d ° (18" VENTILATION, (732)902-62246224 4° ° '4 d d 36" ROOF ACCESS) MOMENTUMSOLAR.COM ° STRUCTURAL d ENGINEERING Gd DANIEL W.DUNZIK RA LEED-AP LICENSE S 039534 ° (908)872-3664 a 370 BURNT HILL ROAD ° d d ° 0 0 0 SKILLMAN,NJ 08558 ° ° J d ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND LU d ° d AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& J ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE ° d 0 COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ° d d ° ° d ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A ° d d LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. Q d ° ° ° ° d 0 O O ! E� A U.1 d 4 d ` d d ° O 0 �vR C d a d d � W D(j,y2y��� O 0 0 i 0 0 _spa DRIVEWAY w 0 O O 039534 y0 4F NES 0 R2 0 0 w CUSTOMER R1 ? INFORMATION 0 C7 BERNA GUVENC U 590 ELIJAHS LANE 0 0 MATTITUCK,NY,11952 631-315-5094 O � o JURISTICTION:SUFFOLK O UTILITY:PSEGLI z UTILITY ACCT#:9626543503 O UTILITY METER#:10410667 ce LL PV SYSTEM INFORMATION SYSTEM SIZE(DC):8.265 KW 29 MODULES:JINKO SOLAR JKM285M-60 29 INVERTERS:ENPHASE IQ6-60-2-US GROUND ACCESS (lYP) MSP - —- ----- -- — AC PROJECT INFORMATION CB DC O INITIAL DATE:10/23/2017 DESIGNER:MM SOLAR INSTALLER NOTES: ELECTRICAL EQUIPMENT REV: DATE: DESIGNER: NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED ® REV: DATE: DESIGNER: PANEL LAYOUT PV-2 1 R1 - ARRAY 1 LAYOUT DETAIL SCALE: 1/8" = 1'-0" TILT: 18° momentum AZIMUTH: 52° SOLAR SHADING: 12% PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 381-511 21'-102 0'-6" 325 HIGH STREET,METUCHEN,NJ 08840 (732)902-6224 11-611 MOMENTUMSOLAR.COM STRUCTURAL ❑ ❑ o aENGINEERING DANIEL W.DUNZIK RA LEED-AP LICENSE#039534 O (908)872-3664 370 BURNT HILL ROAD SKI❑ ❑ ❑ ❑ 558 91-102" ENGI EERING AN,NJ 08LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,❑ ❑ ❑ ❑ LICENSED D ARCHITECTS ACTING UNDER EDIRECTION OF A TO ALTER AN ITEM ANY 3'-101" BRED ARC I �T 039534 �c " SOLAR INSTALLER NOTES: OF NES NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED R2 - ARRAY 2 LAYOUT DETAIL CUSTOMER SCALE: 1/8" = 1'-0" INFORMATION TILT: 18* BERNA GUVENC AZIMUTH: 232' 590 ELIJAHS LANE MATTITUCK,NY,11952 SHADING: 17% 631-315-5094 3'-0" 5'-511 8'-3" 21'-10" 22'-3" JURISTICTION:SUFFOLK UTILITY:PSEGLI 1'-6" UTILITY ACCT#:9626543503 UTILITY METER M 10410667 ❑ ❑ ❑ 11 PV SYSTEM INFORMATION ❑ ❑ ❑ ❑ ❑ ❑ SYSTEM SIZE(DC):8.265 KW 13'-1" 29 MODULES:JINKO SOLAR JKM285M-60 29 INVERTERS: ENPHASE IQ6-60-2-US ❑ ❑ ❑ ❑ ❑ ❑ 2'-0111 G C72 PROJECT INFORMATION p INITIAL DATE:10/23/2017 DESIGNER:MM 0'-O'1 271-31" 2'-011 REV: DATE: DESIGNER: 2 REV: DATE: DESIGNER: LAYOUT D ETAI L SOLAR INSTALLER NOTES: NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED PV-3 29 J I N KO SOLAR J KM285M-60 285W MODULES PAI RED WITH momentum 29 ENPHASE IQ6-60-2-US MICRO-INVERTERS SOLAR BRANCH CIRCUIT A EXISITING SQUARE D 200A PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 15 MICRO-INVERTERS 325 HIGH STREET,METUCHEN,NJ 08840 BRANCH CIRCUIT B MAIN SERVICE PANEL 240 V (732)902-6224 14 MICRO-INVERTERS MOMENTUMSOLAR.COM MAIN BREAKER:200A STRUCTURAL INE SIDE ENGINEERING + _ HOT TAP DANIEL W.DUNZIK RA LEED-AP LICENSE#039534 (908)872-3664 _ _ = ENPHASE 60A 370 BURNT HILL ROAD EN COMBINER 200A SKILLMAN,NJ 08558 J► J1 J1 SQUARE-D 60A FUSIBLE ENGANDINEERING LOAD CALCUULLAETIO SAFOHED HAS SPECIFICATIONS FOR R SOLAR INSTALLATION SPANS &WIND BOX SUNRUN METER AC DISCONNECT UTILITY ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE 8 METER COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. 8 P 40A ELECTRICIAN G D D HANDLER POWER CORP ROOF 20A BREAKER(A) POWER 224 CCOERDELLIP2, QLER ED q JUNCTION f r 20A BREAKER(B) 40A FUSES =GROUND EAST NORTHPOif RC TERMINATION CAP 1 BOX 2A-B 3 4 GRIDoP�\�� DLI INSTALLED ON END OF CABLE ' ELECTRICAL NOTES: 4. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE '9�' 03953Q �O LARGEST BRANCH CIRCUIT IN SYSTEM.OTHER BRANCH CIRCUITS QF NE`s 1.ALL CALCULATIONS FOR VOC,VMAX, IMP AND ISC HAVE BEEN WILL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN. CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON ASHRAE 2%HIGH AND EXTREME MINIMUM TEMPERATURE COEFICIENTS. 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2014 ARTICLE 310 CUSTOMER 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 INFORMATION paragraph C). THE GROUND IS CARRIED AWAY FROM THE GROUNDING LUG 6.ALL EQUIPMENT INSTALLED IS RATED AT 90°C BERNA GUVENC USING #6 BARE COPPER WIRE. 7. INVERTER NOC(NOMINAL OPEN CURRENT)OBTAINED FROM 590 ELIJAHS LANE 3. THIS SYSTEM COMPLIES WITH NEC 2014 EQUIPMENT DATASHEET MATTITUCK, NY,11952 631-315-5094 JURISTICTION:SUFFOLK UTILITY: PSEGLI UTILITY ACCT#:9626543503 UTILITY METER#: 10410667 PV SYSTEM INFORMATION SYSTEM SIZE(DC):8.265 KW 29 MODULES:JINKO SOLAR JKM285M-60 29 INVERTERS: ENPHASE IQ6-60-2-US Wire Temp. Wire Temp. Conduit Derated Inverter NOC NEC Design Ground Ground Wire Wire Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty (A) Correction Current(A) Size Type PROJECT INFORMATION 1 Open Air 2 12 AWG Trunk Cable 90°C 30 1 1 30.00 15 0.96 1.25 18.00 12 AWG Trunk Cable INITIAL DATE:10/23/2017 DESIGNER:MM REV: DATE: DESIGNER: 2A 1" PVC 2 10 AWG THWN-2 90°C 40 1 0.8 32.00 15 0.96 1.25 18.00 08 AWG THWN-2 REV: DATE: DESIGNER: 2B 1" PVC 2 10 AWG THWN-2 90°C 40 1 0.8 32.00 14 0.96 1.25 16.80 08 AWG THWN-2 ELECTRICAL 3 1" PVC 3 08 AWG THWN-2 90°C 55 1 1 55.00 29 0.96 1.25 34.80 08 AWG THWN-2 4 1" PVC 3 06 AWG THWN-2 90°C 75 1 1 75.00 29 0.96 1.25 34.80 08 AWG THWN-2 PV-4 • TAO LABEL QUANTITY LOCATION NOTE EXAMPLES 1 AT EVERY SEPARATION BY momentum O 12 DC CONDUITS ENCLOSURES/WALLS/ SOLAR PARTITIONS/CEILINGS/FLOORS P 1.90 0000-w O Eus 0-900 OR NO MORE THAN 10' __ • • • © PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR POWFR SOURCE _ - 325 HIGH STREET,METUCHEN,NJ 08840 (732)902-6224 MOMENTUMSOLAR.COM STRUCTURAL 0 0 o c Y T ENGINEERING © U P@@(OD MM 1 COMBINER BOX 1 AT ANY JUNCTION BOX OR DC • ',�f, DANIEL W.DUNZIK RA LEED-AP PW'lD S O COMBINER IF USED _ (908)872-3664 LICENSE# 34 �. , 0• OL P• 0 0 O g� 370 BURNT HILL ROAD _• SKILLMAN,W 08558 •. ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND t AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& •�' ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE 3 COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A i - LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. RED ARC,y +k" y a�ELW.pV 1 JUNCTION BOX 1 AT ANY JUNCTION BOX OR DC t DO NOT Mm Tf5ow COMBINER IF USED O D WIN @ m ?@@M O r .• ;�� ---A` ------- -I N� 39534 � o O o cos©• Lam`' AC 1 OF EACH AT FUSED AC C U STO M E R O OP- 0 OU U 91F w EL TR 00 D DISCONNECT © INFORMATION DO O OUO E MINA 1 AC DISCONNECT COMPLETE VOLTAGE AND . BERNA GUVENC OPE A O IOL 264 V IN L O BOH D CURRENT VALUES ON �,� , 590 ELIJAHS LANE O S DES A B N RCy -ED DISCONNECT LABEL I OPE Posl o � MATTITUCK, NY, 11952 = 631-315-5094 JURISTICTION:SUFFOLK UTILITY:PSEGLI UTILITY ACCT#:9626543503 j O UTILITY METER#:10410667 Q 1 MAIN DISCONNECT 1 OF EACH AT BUILDING MAIN -.- PV SYSTEM BURL- 0 R @gdm "PANEL DISCONNECT PANEL x ._ �� - -" �i?��-��. - INFORMATION S OON O 0 S P 0 0 0 AIC - - ' SYSTEM SIZE(DC):8.265 KW I 29 MODULES:ANKO SOLAR JKM285M-60 29 INVERTERS:ENPHASE IQ6-60-2-US PROJECT INFORMATION O OF 1 UTILITY METER 1 AT UTILITY METER INITIAL DATE: 10/23/2017 DESIGNER:MM DU O SO © REV: DATE: DESIGNER: Y' .. S@OONID 0 RO S P OTO O TA REV: DATE: DESIGNER: T EQUIPMENT LABELS PV-5 The new EcoX is an innovative, rail-less racking system, proven .._ -- -.-�_ 5-: to organize the installation process. The flexible design offers a clean aesthetic, r- simplified logistics,and deliversy�- K-`=t �. Y a higher quality installation �� at a lower cost per watt. -4 Aesthetic Design Cable Management A wide range oFadlustment makes it easy to install a Whether installing with Microinverters, Power straight, level system Components are designed to Optimizers, or String Inverters, EcoX provides wire blend into the array, and the aesthetic skirt creates management provisions to both prep the modules, and E. • ` a Rnished look. Alternatively, a skirt Free option is to route homerun or trunk cables throughout the array ;� �. • '/ �; �,� �- � available to provide a more traditional look __ - J -sr .C::F r_:c;��r' ��yt .�:f•i.�.f i- r '7 4, it ii.\C'\\�h\ \.M�,.�,;` ' ,`.`:'.+•.�..• _ `` _ �..- _ ! 7i ;I '-�--tf sF 1 -sF'��� _if._,�}•S._x,-�`� -\ti-"t=.��'\�•.- _>F-va ���'.-',�,._ �-a<-. - -_ __ ,�- ��.= - =f��.` / a�J,'�_!'N!.:%' '� ;r--1-�t= _St Sk�r_:�-]�_ =at�'c='�1;_r: ,':•4=�+.,;;\ =ti:�: =�— ._ _ _ _ __- _ ___- ,s _ Y "F:! -��7 %.i f. ..� _ f lF••' Ca i.,_. _� 1 .�.\,�:C_ .�.3.1�C�`� - _ ON® C --+4T % .. ;!- -.�_ Layout _ �� = _ _ �_ = f SM, °���r_yr s�"-�Ec��l�� _ 1•�`-1t•�.�'�<'= �'� 'tc� "ter f�� _c�`�-�=rte _���.�-•-_'_ as Flexible System Design Single Point Grounding The EcoX Estimator is a powerful racking system EcoX and approved modules create a continuously ,� f �` design tool The user inputs all site conditions and bonded system. The installer can connect a Finished can layout multiple roofsurFaces The EcoX Estimator array to ground with a single bonding lug. outputs a site speciRc design package with engineering specs and bill ofmaterials K w'*1'�ye �-� ': -. - \. ?4j"•Ti ni.�K�».7�e`cl.',fF���31:. is}.+ '�. / 1 ;`C,=i '?T`m,Yea ;\c. r...t•„�+` �-' IJF.; -},''�-'slF;r 7� � ,® y �a w ; `.< ,`a- �,� ��;•�,�,�. ^ t;;=•-� Technical Specifications Racking components.Aluminum, stainless hardware, dark Fast. Simple. Supported. Materials bronze anodized upper surface, mill Finish lower surFaces Flashings Aluminum, black powder coated Finish Modules drop in From above Universal components mount to The Ecolibrium Field support team and there Is never a need to standard Framed modules. With oFFers on-site installation training Grounding/Bonding Validation UL2703 - see installation manual For specific module approvals reach over or walk on modules. a single socket size and a wide and ongoing technical support. Fire Resistance Validation UL2703 - Class A,Type 1 and Type 2 modules Pre-assembled components range oFadjustment, it is quick And From project planning to and quick connections make and easy to install any array logistics to Installation, we are Mechanical Load Validation UL2703 - see installation manual For specific module approvals EcoX easy to install. with a clean, Finished look. dedicated to customer service. Flashing Validation ICC-ES AC286/UL441 Rain Test For RooF Flashing Ad•ustabilit 1" vertical range, 3.5" North/South range, �� l y connect anywhere in East/West direction Warranty 15 years i< g p sales[aJecolibriumsolarcom US•740-249-1877 wwwecolibrtumsolarcom ECotlbrll1mSoar sales(Jecolibnumsolar.com US 740-249-1877 wwwecolibriumsolarcom ` p� EeolibriulrnS®9ae Data Sheet Enphase Microinverters Enphase IQ 6 and IQ 6+ Microinverters INPUT DATA(DC) IQ6-60-2-US AND IQ6-60-5-US IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US Commonly used module pairings' 195 W-330 W+ - 235W-400W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 62V The high-powered smart grid-ready Peak power tracking voltage 27 V-37 V 27V-45V Enphase Enphase IQ 6 Micro" and Enphase IQ 6+ Micro'' Operating range 16V-48V 16V-62V Q6 a n d I Q 6+ dramatically simplify the installation process while Min/Max start voltage 22 V/48 V 22 V/62 V achieving the highest efficiency for module-level Max DC short circuit current(module Isc) 15A 15A M i c r®i nve rte rs power electronics. Overvoltage class DC port II II DC port backfeed under single fault 0 A 0 A Part of the Enphase IQ System,the IQ 6 and IQ PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit 6+ Micro Integrate seamlessly with the Enphase OUTPUT DATA(AC) IQ6-60-2-US AND IQ6-60-5-US IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US IQ Envoy', Enphase Q Aggregator', Enphase IQ Peak output power 240 VA 290 VA Battery",and the Enphase Enlighten"" monitoring Maximum continuous output power 230 VA 280 VA Nominal voltage/range2 240 V/211-264 V 208V(14))/183-229V 240 V/211-264 V 208 V(10)/183-229 V and analysis software. Nominal output current 0 96 A 1 11 A 117 A 1 35A The IQ 6 and IQ 6+ Micro extend the reliability Nominal frequency 60 Hz 60 Hz standards set forth by previous generations and Extended frequency range 47-68 Hz 47-68 Hz Power factor at rated power 1 0 1.0 undergo over a million hours of power-on testing. Maximum units per 20 A branch circuit 16(240 VAC) 13(240 VAC) Enabling Enphase to provide an industry-leading 14(single-phase 208 VAC) 11 (single-phase 208 VAC) warranty of up to 25 years. overvoltage class AC port III III AC port backfeed under single fault 0 A 0 A Power factor(adjustable) 0 7 leading..0.7 lagging 0.7 leading..0.7 lagging EFFICIENCY @240 V @208 V(10) @240 V @208 V(14)) Easy to Install CEC weighted efficiency 97.0% 96.5% 970% 965% • _V7\ MECHANICAL DATA Lightweight and simple Ambient temperature range -40°C to+65°C Faster installation with Improved two-wire Relative humidity range 4%to 100%(condensing) cabling Connector type MC4 or Amphenol H4 UTX �{ Built-In rapid shutdown compliant(NEC 2014) Dimensions(WxHxD) 219 mm x 191 mm x 37.9 mm(without bracket) Weight 1.5 kg(3.3 lbs) Productive and Reliable Cooling Natural convection-No fans Approved for wet locations Yes _ Optimized for high powered 60-cell and 72- Pollution degree PD3 *` cellmodules Environmental category/UV exposure rating Outdoor-NEMA 250,type 6(I P67) Q More than a million hours of testing FEATURES • Class II double-insulated enclosure Communication Power line Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Smart Grid Ready Compliance UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22 2 NO 107 1-01 Complies with fixed power factor,voltage and This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and frequency ride-through requirements NEC-2017 section 69012 and C221-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC • Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions grid requirements 1.No enforced DC/AC ratio See the compatibility calculator at enphase.com/en-us/support/module-compatibility Configurable for varying grid profiles 2.Nominal voltage range can be extended beyond nominal if required by the utility. �LThe IQ 6+Micro is required to support 72-cell modules ® To learn more about Enphase offerings,visit enphase.com To learn more about Enphase offerings,visit enphase.com A E, 017-5-0 phase Energy All rights reserved All trademarks or brands used are the property of Enphase Energy,Inc N �..� a E, L www.jinkosolar.corllgs Budding Your Trust in Solar .21: j—"'12"'S2 Current Voltage&Power-Voltage Temperature Dependence a' Cloves(2901111) of Isc,Voc,Pmax PERC ,w Eagle �PERC 60 1 12 30D E 140 ` ®®®-300 Watt ! .. 10 ' 25D n 120 1 �T a 2w Isc ® u lax i - - I 6 Db 150:-E v 6D ® ( l — max MONO CRYSTALLINE MODULE u� i a z ® 2 an®®Positive power tolerance of 0-+3% w a°° ° 20"J ° 5 t° 15 20 25 30 35 60 rri 09001:20/: •14 001:2 1/• •H SAS 18 0,01 i Fronl Side Back ro -n o zs w 15 tw certified factoIv.1t.ge(v) Cell Temperetur<C) IEC61215,,IEC61730 certified products. ) ( Mechanical Characteristics- I ® a ® t u ■ Cell Type Mono crystalline PERC 156 156mm(6 inch) TZ No of cells 60 6x'10) „ Dimensions 1650x992x4Omm(6500x3905x157inch) " Weight - -- 19 0 kg(41 Front Glass 3 2mm,Anti-Reflection Coating, KEY FEATURES -- ----- ----- _ _ __________ _ . .._.____ ___._.___ _ High Transmission,Low Iron,Tempered Glass _ Packaging Confsgaaration Frame — Anodized Aluminium Alloy ------ --- - --- - -- - - -- _ (Two boxes=One pallet) Junction Box IP67 Rated ®®®® 26pcs/box,52pcs/pallet,728 pcs/40'HQ Container Output Cables TUV 1 x4 Omm;Length 900mm or Customized Length 4 Busbar Solar Cell: - - - - - - -- l - -- ----9 ----Customized---- ®® 4 busbar solar cell adopts new technology to improve the efficiency of ®�I modules,offers a better aesthetic appearance,making it perfect for rooftop ® Installation High Efficiency: Higher module conversion efficrency(up to 18 33%)benefit from Possivated ®� eD"vuatoa Emmlter Rear Contact(PERC) technology. Module Type JKM28OM-60 JKM285M-60 JKM29OM-60 JKM295M-60 JKM30OM-60 PID RESISTANT: sic Nocr sic Nocr sic NOCT STNOCT sic Nocr Limited power degradation of Eagle module caused by PID effect Is - '- ®� guaranteed under strict testing condition(85 C/85%RH,500 hours)for mass Maximum Power(Pmax) 28OWp 209Wp 285Wp 212Wp 290Wp 21 6W 295Wp 220Wp 30OWp 224Wp production Maximum Power Voltage(Vmp) 31.8V 29.7V 32 OV 29.9V 32.2V 30,2V 32AV 30AV 32.6V 30.6V I LOW-light Performance: Maximum Power Current(Imp) 8 81A 7.01A 8.90A 7.12A 9 02A 7.15A 9 10A 7 24A 9 21A 7.32A Advanced glass and solar cell surface texturing allow for excellent Open-circuitVoltage(Voc) 386V 36.2V 387V 364V 39.5V 366V 39.7V 368V 40.1V 37 OV ®® wwuc,a performance In low-light environments. Short-circuit Current(Isc) 9 49A 7 62A 9 51A 7 72A 9 55A 7 81A 9 61A 7 89A 9 72A 8.01A is Severe Weather Resilience: ,Module EffiiencySTC(Y) 1711% 1741% 17.72% _ 1802% 18.3.3% 7A00P° Certified to withstand wind load(2400 Pascal)and snow load(5400 Pascal) Operating Temperature(°C) 40°C-+85°C t � j saoo a• 3r. i Maximum system voltage 1000VDC(IEC) .� 1 ��• Durability against extreme environmental conditions: Maximum renes fuse rating 1511 Bt:sisrart High salt mist and ammonia resistance certified by TUV NORD Power tolerance _ 0-+3% ^ r� Temperature coefficients of Pmax -0 39%/C t Temperature coefficients of Voc -0 29%PC LINEAR PERFORMANCE WARRANTY Temperature coefficients of lsc 0.05%rC Nominal operating cell temperature (NOCT) 46±2°C p C 10 Year Product Warranty •25 Year Linear Power Warranty -PVY LE L E ` ..ENERGY I POSITIVE QUALITY'" MEMBER linear performance warranty y 100% o s>� Aadih Standard performance warranty *STC 'fJclrradlance 1000W/M2 Cell Temperature 25°C C AM=1.5 IE o sss: o^OI vogue from ^ko Sol ��ss; 90% ors/r^eorH,° NOCT: 1'M lrradlance 800W/m1 [Umbient Temperature 20°C 3 AM=1 5 Wind Speed 1m/s d rr°^fy co Bot% •Powermeasurement tolerance ±3% 8 a years i s )z u The company reserves the final right for explanation on any of the Information presented hereby EN-JKM-30OM-60-PERC_1 0_rev2017