Loading...
HomeMy WebLinkAbout41154-Z ��$UFFoI,�cQ Town of Southold 12/11/2017 P.O.Box 1179 a - 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39400 Date: 12/11/2017 THIS CERTIFIES that the building GENERATOR Location of Property: 1205 Route 25, Greenport SCTM#: 473889 Sec/Block/Lot: 35.-1-25 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/27/2016 pursuant to which Building Permit No. 41154 dated 11/10/2016 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ACCESSORY COMMERCIAL GENERATOR(FOR APT BLDG#3) AS APPLIED FOR The certificate is issued to Peconic Landing @ Southold of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED 4 Authorized Signature TOWN OF SOUTHOLD BUILDING DEPARTMENT y' TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41154 Date: 11/10/2016 Permission is hereby granted to: Peconic Landing @ Southold 1500 Brecknock Rd Greenport, NY 11944 To: install generator as applied for. At premises located at: 1205 Route 25, Greenport SCTM # 473889 Sec/Block/Lot# 35.-1-25 Pursuant to application dated 10/27/2016 and approved by the Building Inspector. To expire on 5/12/2018. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO -ACCESSORY BUILDING $50.00 Total: $235.00 —9 ---- Buildin pector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan,requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 - ----------- - ------------------ --- - -- --- -I- -------------------- - - --------- Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: House No. \I�,p (6 r I Street �n I,, ,,� Hamlet Owner or Owners of Property: 1 1. �/v ►tel c l�-F.��1/ &�q Suffolk County Tax Map No 1000, Section Block Lot Subdivision Filed Map. Lot: Permit No. . q� —Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: / Request for: Temporary Certificate Final Certificate: ✓ (check one) Fee Submitted: $ Applicant 7 ure pF SO!/rg®l Town Hall Annex Telephone(631)765-1802 54375 Main Road crs Fax(631)765-9502 P.O.Box 1179 �� roger.richertO-town.Southold.ny.us Southold,NY 11971-0959 Q lycoum,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Peconic Landing @ Southold Address: 1205 Route 25 city,Greenport st: New York zip: 11944 Building Permit#: 41154 Section: 35 Block- 1 Lot: 25 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: M. Turza Electric License No: 41858- ME SITE DETAILS Office Use Only Residential Indoor Basement Service Only Commerical X Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph X Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures 11 TVSS Other Equipment: "Apt Building #3" Notes: 200 KW Generator with Auto Transfer Switch and Disconnect - 3 Phase. Inspector Signature: - Date: December 6, 2017 0-Cert Electrical Compliance Form.xls FIELD INSPECTION REPORT I DATE COMMENTS b FOUNDATION(1ST) y ------------------------------------- FOUNDATION (2ND) z ®O ROUGH FRAMING& y PLUMBING INSULATION PER N.Y-. STATE ENERGY CODE FINAL p ADDITIONAL COMMENTS ' �l0 m 1 � �d b y r TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHACKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined (J 20& Single&Separate OCT ] 2016 Storm-Water Assessment Form Contact: Approved ,20 BDINrr DMT. -IDIa#t ta: Disapproved ale TOWN OFSO D Phone:%m/ nV Expiration '20 ui ing I ector APPLICATION FOR BUILDING PERMIT Date , 20 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to,the Building Inspector with 4 sets of plans,accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. i 11 c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. a��' (Signature of a icant or name,if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder 6 wny�,- Name of owner of premises 1"et om (As A the tax roll or latest d&a) 1 �pplicant is a corporatiorh signature of duly authorized officer (Name 6nd title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on whichr osed work will be e. `goc> ( ac,&:�N ac House Number Street Hamlet County Tax Map No. 1000 Section Block 6'1, , Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other W,,,or. OIJ C�,e �,( �ti .� C,)C,),); i 5% (Description) 4. Estimated Cost we € r� �e,ra A-I%t (Tofl?'e paid on filing this application) 5. If dwelling, number of dwelling unitso` JNumber of dwelling units on each floor If garage, number of cars I d 4 Ca hv(TCs //(Uff we Z.e door 6. If business, commercial or mixed occupancy, specify,nafur'e„and'9M t.of each type of use. Go4+in J (Z:� r- UDimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories (� Size of lot: Front Rear Depth 10. Date of Purchase 1 9 9 7 Name of Former Owner 11. Zone or use district in which premises are situatedy► 114 m of- G r- r c-^a o—t- 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO V 13. Will lot be re-graded? YES NO V Will excess fill be removed from premises? YES NO 14.Names of Owner of premises Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. _ / 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO V * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO—V * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO X * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF_ & Rob-+ q ion being duly sworn, deposes and says that(s)he is the applicant (Name ofindivi&A signing contract)above named, (S)He is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this f _2�day of 0 c��o6-Gr 20 ,A-, i L G.Cma11 Notary Public Mysum Of Quiiih'6edinSufol�cCCo�tYj►� Signa of Applicant No.01CA5009515 Commission Expires April 29,20-” PERMIT TO CONSTRUCT Toxic and/or Hazardous Material Storage Facility Suffolk County Department of Health Services JAMES L. TOMAKEN, MD, MPH, MBA, MSW Commissioner SCHDS REFERENCE# 09714 Date of Issuance: November 10,2016 SCHDS REGISTRATION# 10-0195 Permit Expiration Date: November 10,2017 SCHDS PLAN# HM16-161R1 =FACILITY NAME,&ADDRESS: Peconic.Landing at S,outhold�'` 1500`Brecknock,Road Greenport,NX.41944' Your Application for Permit to Construct,a Toxic or Hazardous Material-Storage Facilities for the,above referenced site has been ieviewed.for compliance with Articles !'&'i24 the Suffolk County Sanitary,Code: Tlie`ipplication has been approved. The items listed,below and on the back of this Permit are conditions of'this Permit and have to be observed-during construction:• ` ` 1. . A copy,of the,approved plan must be kept at the construction site. A copy of this permit must be°kept-,on - display-at the facility during construction. ,2. Safe'construction practices must be followed"during the installation of the storage'facility(s).' , 3 The storageryfacility(s) must:be constructed''iii.accordance with the approved plan: Any chariges',in;\; `design,materials or use require,prior`written cons'ent'of..both tlie'design professional anci..the Office of� Pollution_ The changes,haveto•&-1-submitted iii'-a form that is acceptable',",to the,-Office of Pollution,Control. The contractor.aricUfior,,design,professional is-requked to inform the owper••that the., ;°r changesAre being made. w; , '4. The Office of Pollution Control has'thevrightt16;inspect this'installation at any time to'verify-its being: constructed in compliance with this permit., The Office of Pollution Control must be contacted at 854-2523,-af'1e'a9ts2'b isiuess days prior;to commencement of ' any work to arrange.for the required constructi6n4mspectons. r - Coritact the local•building-department and/or fire^safety enforcement officefor any additional-requirements that may. .Ippl'y.to your project. Thesforage facility`canriot be placed into service„until the•Officevf`•Pollution,Control performs all;"required .• �. ,nt installation inspections and issues an interim permif to operate. = The Office of Pollution'Control reserves,the right ib revoke this,permit,aCr allowable'liyaaw. ISSU BY: - Alexander M. Santino,-d''E. Principal Public Health Engineer,,.• -. Bureau of Environmental Engineering Division of Environmental Quality SUFFOLK COUNTY DEPT. OF HEALTH SERVICES APPLICATION FOR PERMIT TO CONSTRUCT TOXICIHAZARDOUS MATERIALS STORAGE FACILITY SITE 1 LOCATION INFORMATION Business Named �, Contact Person i is l Cr t>if C, �"� r .a�]9!_�9 6J`JC ?tom) ��l��i� PCS Physical Address Community State Zip 0944 Mailing Address cr atrret rr m pti siew odren) Community State Zip Phone Number Fax Number- E-Mail Address -1 OILC TAX MAP NUMBER District t Q'�� Section Block Lot STORAGE FACILITY OWNER INFORMATION Storage Facility Owner's Name Contact Person �� a� L �s��� a • fibs--vef4 cA(zitou_ Mailing Address Community State Zip Phone Number Fax Number E-Mail Address PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT INFORMATION irm/Professional's Name Contact Person T'i t cwc-&-L- i vf-3v azerkr-, Mailing Address Community State Zip Phone Number Fax Number E-Mail Address Scope of Article 12 work: (Check all that apply) Aboveground Tank Upgrade Existing Facility Piping and/or Dispenser Underground Tank Transfer Facility Vapor Recovery Drum/Portable Container Dry Bulk Storage Scope of Non Article 12 work: (check an that apply) New building construction New sanitary system Addition to existing building Addition to existing sanitary system Renovation of existing building Upgrade of existing sanitary system No additional building work is to be done No sanitary work is to be done ,rot •..fi fl+ ,� �.` ••. i-�+K/.i b.. 0 , I .I�w�.+:Fw�;a/. ...••.a•Fix:.P`.si4-A.j.,i+•.F!s} a•,F`7... y`� aS•+�z'''.'at+yr. A��--,'.�.3i.+'+�C`-1+:�...:tai1-a•i..:-.»,a _Tk a. 4....-r ir.';?it-a. ,t�..,•s '94d•�=1•ti,3_:fa�-.+S;.:watic+r. i3'�5�+"15• ��� a l'� . .-. a. r0.;, :.. _ - « _v.::` tlY',4"Y:V' •SS• C' 'aa •-.+•'1,.� sMt sw! Y>.v q.. .�1. Slf•°,,-. '- [[__ a��.:, .�� BfB,,�1 :IC�1��A)<' �-��=.:��• .� Iff,�+[11,11P�2• �i�'.�`. .•��. '-%;-.:a:, �:3:'..+t Yt A::. _4'... i�+3:.... '. 2.-•." yt��..p- .!Y�w,N. } P�..-...s,. -.rrs- k>'S rS•tci.ii �� T7 � :.,z.. '� t_ _,y. Yy.- •'%':A+.•..ri• w'� '.: .. 3., �-,..r(s •�'�C, u.y � .�i.•,r •.� ,M vt:�� r�, i,.-. ';iyy�. r.�•� ?-�}: .. '1:�!�=•Z•� .l.a .♦ ' ._ • f Y-'�•�' ♦ _ ..-.. -T S.�•-r. K;-'f�} .�. a� • --'!%h , • :}i::•T' - • .- - 'i• '• ;P♦• • - '� � O ari�fPnllr,rlru:�,',j„rrrrl; '`�'” IOOr R�•:a•CS n Scott A. Fussell ,�� �� ST01KIM[WA T]E][Z SUPERVISOR M[AN A(Gr]EM[]ENT Z SOUTHOLD TOWN HALL-P.O.Box 1179 p 53095 Main Road-SOUTHOLD,NEW YORK 11971 ti Town of So u th o l d X01 CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT ECT INVO LVE ANY OF ')('lHI]E ]FOILILOW INO. (CHECK ALL THAT APPLY) Yes No ❑ErA. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ [3/B. Excavation or filling involving more than.200 cubic yards of material within any parcel or any contiguous Lirea. i ❑Er C. Site preparation on slopes which exce(Ld 19 feet vertical rise to 100,feet of horizontal distance. ❑d D. Site preparation within 100 feet of we0aWs, beach, bluff or coastal erosion hazard area. ❑Ed E. Site preparation within the one-hundrei 41- ear f loodplain as depicted on FIRM Map of-any watercourse. t F. Installation of new or resurfaced impervious surfaces of I;000 square feet or more, unless prior approval of a Stormwater Management t Control Plan was received by the Town and the proposal includes ! in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. S APPLICANT- (Property Owner,Design Professional,Agent.Contractor,Other) .C.T.1V1. #: DOO'Ot Date / 9—tet NAME U dl -7—l (P„nii Section Block Lot OR BUILDING llEP�\)t'I'1lEi "( U.i`_ I t)\I_y ' •X 1 Contact Information. fdrpligrc�uinhci, - Reviewed By: � - - - - - - - - - - - - - - - - - - Date IQ—a?W, Property Address / Location of Construction Work. — — — — — — — — — — — — — — — — — p� Approved for processing Building Permit. e SoC� '�(e c �T( { aJ — — Stormwater Management Control Plan Not Required. p V 7 'r' hI Stormwater Management Control Plan is Required. !J (Forward to Engineering Department for Review.) FORM * SMCP-TOS MAY 2014 Nov. 3. 2017 10:45AM No. 1139 P. 5 so Townal1 Annex / Telephone(631)7&5.1862 54875 Main Road P.O.ld, Hox 1171 ro er,rlchert `(n;quu o .n ,us Southold,NY 11971-0959 � ^� BUILDING DEPARTMENT .'OWN OF SQUTrlom ' APPLICATION FOR ELECTRICAL IN19PECTION IC EQUESTED BY. Date:ompany Name: -I-• jlYl ame; License No.: Ll 1 ?5$ M -- Address: Phone No.: l- 5 ".�773.3 JOBSITE INFORMATION: (*Indicates required information) 'Name= - *Address: *Cross street: Street: *Phone No.: (P31 . i11gpa Permit No.: be HIM Tax-Map District: 1000 Section: 3 5 Block: Oi Lot: *BRIEF DESCRIPTION OF WORK(Please Print Clearly) � IW/) (Please Clrele All That Apply) *is job ready for inspection; a / NO Rough in Final *Do-you need a Temp Certificate: / NO Ternp Information (If neadod) *Service Size: 1 Phase (8Phagh 100 160 200 300 350 400 Other `New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLIGATION log 82�Requestfor lnspeGUon Form CHARLES R.CUDDY ATTORNEY AT LAW 445 GRIFFING AVENUE RIVEIZHEAD,NEW YORK Mailing Addrgeg; TEL: (631)369-8200 P.O.Boa 1547 FAX: (631)369-9080 Riverhead,NY 11901 E-mai): charles.cuJJy@verizon.net September 27,2016 Michael J.Verity,Chief Building Inspector Southold Town Building Department PO Box 1179 Southold,NY 11971 Re:Peconic Landing at SouthoId,Inc.-Generators SCTM#1000-35-01-25 Dear Mr.Verity; This is to confirm my conversation with Heather Lanza,Planning Director of the Town of Southold concerning the proposed addition of three(3)generators and one(1)replacement generator,each of which sits on the slab 6&by 12 ft.and is used to supply emergency electricity to the nursing facility and apartments at Peconic Landing. Since the generators,as above described,do not impact any parking or cause disruption of services and are fully screened and are de minimis,Ms.Lanza indicated that no site plan is required. Very truly yours, NA%40-/f. ` Charles R.Cuddy CRC/ik sp., rt 1 1 1 e1c OD dc USTI` 1 ! ! T / 7C� ! ! ` 4V A 3- A ti vAF tic 91 *C, ./Clc 0. (o C, .ro fl,r''"i'� / � ��\ ;l Ja: '�`•• F' /`/ � T /YQ'9" rob' �.�')�� /.! .".,, � 61 Ay k, 4- P., N, 4, V lip y 44 , kAl O/A( N 25*50'1 4"W -- ——— ———— —— IJMIT OF Icic z WETLANDS ���� �E, v ' {�� \ 4L 011 _My J � 1, _ _ .� SCENIC EASEMENT - 40 /# un cktv6l, C) Q. POND -umn of it 1 VOLANDIS Izz, Q A WETLANDS �IM-Z/43 H 1131A Q) 16,3 1A d Px MIJ#3 Z H-281 0 4' MH Z1019 41 V M14#9 IM-2177 -10 l, $-AH#V SM 'J& RIM.-2 00 SMH63,13.2 1,114W.0 7 ea, Fq-L,�, fl, IE' 2B 9 ✓ RIM-29,60 H .1 A 0 MH12.10.6 RIM M13 43, R- .2837 C, z; FIIII-1460 5" A. a. NQ 1 Milo 03 �-LLJI film 29.10, M-3113 MM-28,42 M81.13 3 lomf 9, Q z RIM-28 78 cl�', 4, /C> r,44 9.01.4 IM &B4.-- SS,BAH i.3 0 CICClIto i.0. 5- 45 .79. IC U C, s—— 1cq--,r, z `�f /T•-,,,� ..».,/ r-_ SOOPG OF WORK +y t�'"i •' .:.¢s.,•,"T>",`i7°�.xl a' z�..>iy,'�'d;M.. I INSTALL(�NEW TIO BALLON DYL GENERATOR DAY TANKS (AREAS B L a D)2(U NEW 1,949 BALLON DY1 GENERATOR '8++'^��.FF•-'•}''.•.•c'µ�s..•t. Z_�S:'- #S¢,'f...." yx•�� } .r,�ja...,n,t�a,. TANK(A9✓PA A)AS PE3t PLAN PALKAGE. INSTALL NFYI GREEN ARBORNTAES SURROLTIDIt9G .{t.y '•y,.,rw..:'{`: �Yr:' {.�.•.;, L'"y`�k;. �yt•.Gy TANK5 AT ARBA90bVVR L A DAS IfmIGATm HEREIN i� sM sh.. .�r F•tnT� �..yT1�;`S} �.j^J^�:.o'4._ ,•",'s. • -IY�• _� ` (� 9 TEST ALL SYSTEN6IN ACOORDANOE YUTH SLPF0.K LQ.MY : `x '•' ' , •Yit 1j ��ry•:.j..IS(r` s .,��°`� �.r<',�'i ••' 2 w^• 4 RESTORE% ALL DI9TLRBED AREAS TO MATLH ExsnNK Y:il3• ?.Fi. AY:I•' } fl- -%T ',4� • �l f fma 3 F 9 :+.: ".;Cs t'"•1:'yv!'?p y3r +•":`sq:'k": f`9t�`fir -a. MITlw <•- • .`'.4 T 1 �%'•G"" , /•-.q .t : 2 "( i I AIR PRCS`wRe TesT TA»ts PwoR To INsrALLAnoN-s Psl PwnARY. '.,,.,:'r.'«4```L{'� '`"`' ��2"at';1. ".S'•'..,,q^ w. ..n .'^,. fi r;'rt.r „ 3ii.^' -J '+;.F,'`eU.. �• n, 5, ]P515EG02IDARY t#a "Q4"�. 'rye t ` - -`wE4:' -1'• 71 r 'f. •t r°;� .^^,>, .. •.��'_ .54�'�:,r Yy�..•••'-L w�f.r , - F 2 AIR TEST PIPING SEPARATELY PRIMA.¢,PIPINb AT 90 P51 ATID + •t L4 _ 1 6 �C IAARY AT 9 PSI BOTH FOR 90 MINrtE+. %1. '' i dk,'�' •2r'xi. Vl' }•`a2'`N �' L.:_'t•--„s_A•-- ,. ,.r, __ _ __ rr�� �;c. t;,,_ ` Vis• ••i,::;. '_3 � '*r�”"'R# _ 'i 'y�� �-- - _'�,_ __ :{�asaa lv .,••M.Y` s �r�TOlncaPDRM ra EOLAL Srrre Arm FEDERAL �l t _q. 7 [Y•. v. ^` •v: i, "a:^.' �... "AliD roof...5'. vt: OONTRAOTOR(S)NOtE6 I LOHiRALroR SHALL OtNiiN@ T2@ SITE ANO-y3�' {T S.a � � •`p,. � •F VHZI „4�F wry, FY ALL B%IsnN6 UNVERGROUND TAN,`5LOONKS ANO m N s`i$���•'ir' k' "e i7�'i'e.';�.-,". tw i•e :t• {[•'`2' S9�-Ii f,�-. »'••s,�f G ,''.fT+:_j rt.r \, ' �TING PIPINb—TO nME OP PP—CDWORK. xa �y;y.F, ",gyyp rF r �T �Ta;z�, ZONINGS DATA v{ S SI h'3! e e,+r7't4'nJ "A'-••`�'. •,� 'a ru••A tet'•' "• I { UNDERGROUND UTILITIES �'` • / ^: r.. �•„y S,•rf , I THE EKISTENOE AIm LOOAYGN OP ANY UND NSI­ND V LITY r �'.' T' i' },•, ' » • •^• �'•_,: ` ,.�"..•a. ,n , j , PIPES,LONOUIT9 OR SIRLGTURES SNOPN ON T16.£PUNS ARE CONTACT INFO. ` ;r`¢'2•f; { `l2 ' - -~K' y' �`O•�" M`''✓ r'` _,-_--.i.-_- ___._ OBTAINED BY A SFARLN OF'Dff AVAILAELE RELOIiDs IT'S I -AT`�mIOLO.INc f Ar i ry i,., l's• L ' .•- '+�: _ POW IBLE THAT iIERE MAY,FORTS ITEtS.BE DISLfr£PANLIES `',2' t yj ::�`� "•r t ,� E y'>'"�`< � �1 . 7-,;( } •`�'�i'' �, t�_ I ANO/OR 04I5 VON5 IN TIE LOOA7ION5 AND QUANTITIES „ r,.: -GF•'• I UT IJYM MID STFUcrLFE J10vdl._THE B TOP OUR KNOVd.EDC•E THERP ARE rm E%ISrP16 ui0.mEs EXOEP(A5�IIOPN sTt'VLN LAw+AL-CPO ON_PLJJLS THE OONIRAOTOR 15 R I,EO TO TAKB LLE (69U 441�.DL'J N]]4 J f 110,...7. •,.. '-t'� if fl Pi OWf10NARY NR?5LRE5 TO PROIELT THE UNLIT,LIID-5 SHOWN PPLONIOLAtmIN6DRb { V .y ON THOSE DRAWINGS L 1 _ v, `�Al `T ,, f r»' u• ,yi,,.O.•.� MCA 0151 V +;il INFORMATION, •'�: - MGOfi -L,.. R: 2 " ibRK'D�<�,e`�:` 2. ..r. , i� loon-9s-I-a ,' •! y''2 `,`2•''9,. r1�K " ~', 'n„y -"f` J Mw`s. { _I. ELEDTRIGAL INBTALLATIONO I ALL ELELTRILAL INSTALUTONS AND EOVI ANNE SHOULD INSTALL®AND HAINT RIC M ALLORD C! WITH �.i r. •• E L` _ �- .. - ___ _ t p� ' NEPA TO NATIONAL EIFLTRILAL LODE,ARTICLE 514. h '••ii r ii _ 1� ] LLA55LGROUPD.DIVISIONI'' •1 _ _ *'^•* 'i '�,,,-,. __ tl ] RUH ALL NELESSARY LOrmUlr AND M IN 11L ULIS PAB TED PROM PROB[3 - {�; -r• r r.,aay.-' l f .}� ,:1^ " • + tC - 4.•`^- �, "h/ TO MOwTOR T✓a 2 1[3tMJNATE -_ 1• ,��. ,j ,t+-�i T )```, a. =. :i .'{' , })"' 'L WATERPROOF,UNLnON BOAS RMS01' DCSCRmIION NAME DATE fti•'�a- - 1 ! PREUYINMY DESIGN f5H 9122016 rU1eK A' -,_ _ L �1 -- il3• _e,� 'Yj i T" •1 f - •i. t _ .- Ii _2 _i--_cousm_u_cn_ou o_o_cinecuis_--._vli-f_szazms `»»~t•• ` •�' .' I�'t 3 - ADDED SCREEN PLANRUGS O TANKS FFH' 10102016 �S!i A__- ___!EVMLAj PCR SCHD COMMENTS-I VH -10312D1B J' ;t t T' `"'/•1 z a� t �'`~ t t. / r 'r" =r 1' _ »,t _ __ ------------ -- _ s}� ff.�4,.b' 'Iia }�'li1a,..•»c ,`•,• Yj! �/ •V,'S t�^ •-rF + • y _ -___ ____---_ • G'•`.I .r(c iL4�'*4-;°Kra%•, +;Z {t: 013 1, t- ,.a��-''.'i`' 'e^-`^.=fir t _;,r 1 I __ - - - �� 21,1 , ,. �-'�T.,, ;:x-'~-`': � �`�"F : :;' •____. � __ h -- 1' Y 'S u ',1•• � S--•1'2`,��f« A_ i r.5,�'}.�;';:t .���p�w iF� �r--. i aw_. T .,.. , .. ., rH �v♦- ..�- 't� . _ _ _..- �- M - - �..- n.•-,,. -.,-,,.`.', ..i„4 q Pr..GC�A`. (/���+.Iy��/pL�1����y��:�! //u�� (/���1 //o�� YS.I �� �� •” ..- -."' •' r �.: - Fes~ ' zl y4;.j - 6 IErt W LYJlo�J9�la SL'AA'� LSLJ®�OO�l�to���� PERMIT ACQUISITION AND EXPEDITERS MICHAEL D UNN, R.A. 1981 UNION BLVD BAYSHORE, NY 11706 (631) 665-9619 FAX 969-0115 '4'c 'ENVIRONMENTAL COMPLIANCE 'PETROLEUM$PECIAUSTS SCALE,1'•2GD'-O' —_ __--_-.-,._ _____ -COMMERCIAL 5TE PLANNING -PERMIT ENPEDIPNC PEGONIG LANDING 1500 BRECKNOCK ROAD 6REENPORT,NY 11944 PROJECT DESCRIPTON SHEET DESCRU'TON GENERATOR F-LEEL TMKS SITE PLAN 6 DETAILS A P P P O v A L 6 gr_­-p •, Y"�RoF.P�P�a�5��aL' 1 NAP/ 1000-35-OI-25 - SGA1E A5 INDICATED oGg 160803 DRAWN BY CHI('D Br GFH 6W6 DATE SHEET an�nb v 1 , owLR I OF 4 !1 r• 9 v; ITr~ 6RA55 / GRA55 �. .Y.. •v�.A. ' a,aii:9.;..tom': `a'.•C"„a4,)4,».S ".'`"y.:tr'1..y Ar ,a'•}.t 1018• NEW 200KW CUMMINS �/ ZONING DATA / DIESEL GENERATOR E%15TING 2-1/2 STY f f j• UPON NEW 710 GALLON DA PAY TAW,UFON APARTMENT / / CONTACT INFO / / - •!fj. NEW H TNK GONG SLAB BUILDING / // 6RA55 PFLONIL LAMIDIN6 AT TiLIlI1101.D,IEIG. / P I BRELIJI:I.K RD NEW GREEN GIANT / SREi=w113Rr,NY II944 GRAVEL 3' E%15TIN6 2-1/2 SN- / ARBORVITAE PLANTINGS - ��T'1'SYRmV"PrsC52ETR 1 GEo ` APARTMENT '�• ®4'-0.OL(II SHOWN) / STEVEN LnarsOLL-LFa Sq5' �'LTJ' BUILDING T APARTMENT (e9U MTiXOD x334 '�� j` BUILDING eELONILL.AND'tkSORG / NEW 200KW CUMMINS %/// �/ TAX MAP INFORMATION DIESEL GEY.�RATOR / -/ UPON NEW 710 GALLON / DPI DAY TANK UPON r ,f' �/� NEW 8°TNK GONG SLAB NEW GREEN 6IANTS6 Q /f ARBORVITAE PLANTIN65 /J ®4'-0.OL(II SHOW REN90N DESCRIPTIO! NAME DATE 1PREUMINARY DESGN G 912 2016 2—i M CWSTRUCTIDN DCCUMENM _CM ; 9202016 GRA.55 / 3 ADDED SCREEN PLANTINGS D TANKS GEN_ 10102016 4 i REVISED AS PER STD CCMMjN15 GM 1031 i016 EXISTING 2-1/2 5TY. -- APARTMENT ---- - --- - AREA OF WORK 'B' SCALE.1•=20'-0' —}----- -- _-- AREA OF WORK 'G' _-- SCALE.1'.p-O• GRASS EQUIPMENT LIST ( 1RIAE1ARR / 66 q• GRA55 0T,` EQUIPMENT MARFACTMR MODEL WIRER PERMIT ACQUISITION AND EXPEDITERS �� \�• A/6 DW STEEL DAY TANK MICHAEL D UNN, R.A. ' = 1 W CLOSED TOP DIKE TAT HANFACTURING." 1445 SAL W UL142 LABEL / NEW 200KW7,V—MM-1— P/6 OW STEEL DAY TANK 1981 UNION BLVD BAYSHORE, NY 11706 3 TRENONT NP.NPALNRING,LLL 710 SAL W ULI42 LABEL / DIE SEL GENERATOR WCLOSID TOP DIKE (631) 665-9619 FAX 969-0115 UPON NEW 910 GALLON NEW GREEN GIANT / DP!DAY TANK UPON 4 ALARM PA1Fl OMN1E0 LIPD3 •ENNRONMENTAL COMPLIANCE 'PETROLEUM SPECIALISTS ARBORVITAE PLANTINGS NEW 8•THK OW-SLAB ®4'-0'O C(11 SHOW 'COMMERCIAL SITE PLANNING -PERMIT EXPEDITING 4 HIGN/LOW LEVET.SWITCH OIRREC L-25 4 NTERSYTTIAL LEAK SEIGOR OHNTEL L-2-5 GFZAx D avEInCAP oPW 23-ao30-oPBIVENT PEGONIG LANDING B EMER6ENLY VERT FDRRISON EROS 344 1500 BREGKNOGK ROAD GREENPORT,NY 11944 4 FILL LIMITER MGRR SON BRU ADAAMR 6U OM14C G PRQECT DESCRIPTIQ4 SHEET OESCRIP110N 4 sere SAUSE SLLLLY 6OLDEN GALLON GAME _ CPENERATOR TANK5 AREA5 OF WORK B,G 4 D APPROvAL olPARK d3a So 99{P °' WY n 1 EXISTIN6 2-1/2 STY. / TAX NAP# y APARTMENT1000-35-01-25 BUILDING �` SCALE AS INDICATED / D—# 160803 DRAM BY CHK D BY GFH 6W6 DATE SHEET AREA OF WORK 'D' D 9/12/16 X 1 SLALE I•=20'-O• 3 OF 4 LONG FILLED 5� � .i5� i,l••: '+ : # '�..J�< h`,*- . PIPE BOLLARD -^^�� : r. „' c.. • y OVOEA SIbu PDSATLFD ABWE MSPILL BOX d�5'�.°:., v .�i--•�'. 21aD9uB. rEuory C + - LLL DO NOT DYCVILL GGNG FOOTING 4pD0 P91ztY'§• •r1,.• � i-«`-:_ ••��.'�^�-'r V°•' .3•- EXISTING I STY. / i�- `•)t YF=•;..: ^:?., d5nwll wLABEL IwND!M SPILL Dox 9TATA w D»r PaL cow,e<nox 1wr ce wm um w ..� LOo• cDwccnox w.x IM —A Exlsrl)u ewAVE •, .x�er ':t TE % DiEiEI PiF1' N R /// ?(ti. i p y.L� �I 1 '� r,e nLL PORT DHNLt.DEARwcDLDR coc><roR \, /' / � "i '. :ta• la'i: -.,�1.' :�_•x�i4:S��+ IexL Pte d ATF.OXDANGB rv)r»M M _. YELLOry 1ExAsoN Alm em Puri ew LADELD Dxsu ee PmrED o»Au vISIDLe Dmn �• •\ // / % � ,c.. Y�.te,.s E, )�. } s.ti: �GMOMnOx)I.iANt NT»M roLtLwwS 7 / / / i'� pf��`.•�:y;i�-:.'•a'.:,•` t.. NEN 4'GONG FILLED ... 'V:. �y f f;.E.>•• ^'.y'�'i+:•:'.,:a-x,. ;w 9`i"': rYTlxrx4 cAPAcr1r a rANx C•_ / - 13OLLARD5(MAX / @"+T„�•`y ��f .,t - pro.r.t^ t r. 1 .: .>��� k iy ' 4•-D•oc _Y�,,,C. E.ewsxeY sE1H,ATpt e.A. TAucs N»sR BY .�(. / EXISTING 450 KW y 1Et N'i%'°�I.d�i�{'t-;a,. ""i• ,ReHONr HAMaAe,ulds LlL uee DERres,oD DIESE / GEt �1e,/ cto�roP Dlre TAwcs w ULIR LAeE�n L ffR4TOR UPON NEN 1445 GALLON DAY TANK 50LLARD DETAIL _A"'EBLnG-w ZONING DATA GARAGE UNDER j NOT TO 5GALE j ASPHALT CONTACT INFO .j % P6GONIG 1ANDING AT EiWIIbLD,IMG / 1500 t3 CLIQIOLK I0 - / ROOF / bf+glfFORT NY ILMI OVER l ^y POBERT 1�TRON-PRT.f IDETIT.GEO Peen halm BOLIAIro EMRy XISTING Ex TRANSFORMER GON ENUNITY CENTER PFLONIGLANDR160FG ® • ® %/ EXI5TING l5D KN DIE5EL i TAX MAP ORMATION DAY TANK TO RE Da9Yt• x DPDS Die) ./" GICOO-35- -DS — fa-O'nAgD#aae�t ENETUEwY vFRT / ' ! E%15 TINGENERATOR 1,250UPON GALLON INF 29 fri4-ca99>SEcgouaY MAIN ./-n-u• ATMo^.PN6tIG VENT%'ATr •�' GONG a ———— — — —————— •oYERFLwY onER( GRA55� I I I GXa� DPAGEw f - -- -- - 7 i RE`DM DESCRIPTIM NAME DATE PREIINMARY DESIGN GTN 912 2016 J \4 t PRS E ZPDfl GY VEM GONG 2 CCNSTRUCTON DOCUMENTS — G H 9 20 2016 na ( 1 I DP ral TwNe —.—L-.w 121w Llee / uNVJ wbx ASPY44LT _ __.___ _ 1 j 3— I ADDED SCREEN PLANINGS®TANKS UH 1010 2016 47 RD AS PER 5CHD COMMENTS GM t 10312016 _ ENSE s • S 3 LLL L DP INrtCR W o),aP TSE. i'1�) /' IAB Gr PRIW.Rf TA)K �/a ordlC.W-9 xIM1dN wlma SIM L——— —————— —————— ___ - Q � LEVEI.SN)TUI d 0•LVM i _____ f r -___— _ _- _'---_ VEur w 50ALY rvw4TE ' YBIIi GAPP.D'AiT jr // 1 1,445 GALLON DIE5EL DAY TANK PLAN /�/ --------- —i - "------ SCALE,1/2'.1-0' AREA OF WORK 'A' N �_- . scaLE.1 .200 ,.• � _ aElIEXATDIl ADDVE _ _ 1�- --- c aamax mwaam 9395 - -- - - - - - -- - PERMIT ACQUISITION AND EXPEDITERS MICHAEL D UNN, R.A. v LEVEL voce 9w.0 1981 UNION BLVD BAYSHORE, NY 11708 vE ns wDx Llwa LEvp.Auld+ I -- - -- - - - --- I (631) 865-9619 FAX 969-0115 i I cwP,A.rcilr's'�ne T I ra rw.wY wo.clw,vExr W A.LY du41LE VE»t cwP s •ENMRONMEN TAL COMPLIANCE *PETROLEUM SPEDALISTS 96•ATT fAea D-o ABDYe •COMMERCIAL SITE PLANNING 'PERMIT EXPEDITING �xN PEDEL btdEFATOX GRADE,HBU i ' NFD cuHsyne.ortR easwnDX I»c i A;�alRro Dl'PABO.'E M OIOREGyELIPDa N rn w49CGO'�oa" ' I •nDELi aEp DPT.Iw Fans I 9Dagoe.wx) nal rT I b'M:R640u f3MU crs >El16ExG vw n IDesnueow PEGONIG LANDING qi L[VEL AuxN DDULau PLu4. 1500 BRECKNENFORT,NY ROAD GREENPORT,NY 11944 BNSOC SPILL DOxI Y Vl,nf� _ PR0.1ECi DESCRIPTION 91EET DESCRIPTION 7 I I — EixG Veur ——ARY Tuc t_—— .rw�wTu°iA_�yae�—__——, 1,•, FILusPIu cox scum ro GII•ERATOR R1E1_TANKS AREA OF WORK A ---------------------- — 1a-' APPROVAL S �------- bNRY TANK------ I I `T� u�81o"�H yNe�I al a `C'S�Ee'�6Pfv4 F5 �°�",a7'i' tWLIDN I' STlGDAR(TA.R 1 ., ,,,. ' D0DXE9LL TALL SRR D•wwu>a+EPDD 9D•E,DS Iul.. p1T TY[ PLLL LMIn9i W ncDP NZ ry i i 7 lAl[�L ' lLT96 A I wDAP1ER.LOccnm cAP �.yl. ° ' TAX NAP/ I —————————————!��—t'�°Y'—————— —— —�/ •Txwc Pc suD w axv IDnD w++ e - -® 'AD W' 1000-35—OI—25 L»c DD DAYycEen(allo PDI SCALE AS INDICATED DWG y I I 160803 SLAB * T `'V'D L DRAWN BY CH»D BY TA off IFGxAIAEl w fb1 IN�L'NSn»D SLore � »FR GFH ovic, DATE —ET 1,445 GALLON DIE5EL DAY TANK ELEVATION'(MFG 5Y TRAMONT MFG, LLC) DAY TANK 5112E ELEVATION 4il�nb X1 DWv p OF4 SCALE.I/2'a I'-0' SCALE.I/2•a I'-O' .r t ri.t kR" "` •d�1. "1sr 1'•�.$(y Y LPiVl.1 S..K,' (*�"S IiY.:,-. ."'��1.M1S'.:/,;;a Sit� r'.Y.as',5�:..�••Jy;,'-'S,`"JY�..e y'.�. ;>'n..�;; Y.q�iT-�1.T�T:'<at'�`l�s:a''I:�'••',,.sTwA: xALirmane veNr c.vzne•nrr }yn� .:ti<.A-;ova; Ir` ¢''�.:s q.,-•,�:.:-'.«,•��"."�'', P..Rr rnaa�ve,aw +;" ^`��'c�'-::jn~�t•~'�..3,g.;••.aT��'S,':"'�:.i:,,:.�='�. a secarowRY w+r se•nrr L-]-9 NVIq bE1HlAlOR eVNi^vMxcM W]• ----------- --------- ---- --— - --------- --- - �w seeovowRr ZONING DATA sewlmiv1Or rwwL 4 i�_ sawmANz"r e.eNee er var OPrrOoNNlcdu mliru�salmuLv lerG. ———————i 16I-——— e L-2•s nmRsmuL LPAK 1500 DReeRTbGK Pa LJ semR n eMae aso ss+n.um_s, zlas�.warsr,lrc naNa , / � I .... -I/� PRI °`vnn Prio�w seen Posry Aeo+e ra seal box R�i srROH-PRezn>EDxr.cEo q I // I elmR..1aR I ' Ew.w Novi�m+xvms T,e r,uc Is wL-4 IPWaµii�INzo=Rws mY / I eRwc� � a i I -°,�ne�Hr:LAen n+s�re ne spur.eox zrwmu 2 1 / I 1 wY°Lsc�ui ro w s�nu row I I i ' i rsP I��/� �' crone LOD'HeH o�seL�• TO TAX MAF-INFORMATION I————— L———————i— — •xrmRVLw ovslL r.e PIu.Poor swu eeAR w coLOR was POR I000-ss-I-a 1 �srwce w ass�na w Acco�wNce w*H m n.l snav'�i,RP�w c•-Y V IrI•rrre K correR u•me K O9net a srAUY sne I cone srwlmwRn aieseL wsL n A swPly LVF w uw TtErNM Lna w ew L I rsiLory IexneoN Z _— —___ .—__— —__—__ ______— rwNi�rw eO'x xiueo m ( He wxN r,e ProL^LLionvu�®Le sores rwlic sub s�Pu"n twHK YneeR HORvsoNp ru°�°sse rwNc GOM6M8 9iLY1 R6 wawr,gx• Ns GAP ro�Rcob wP�a rANK r-22 DCSCRIPTON NAYC GATE PREUmNARY DESIGN GM I 9112016 CDNLTRLTC m DDCUYEMS ,GM 192DIDI6710 GALLON DIESEL DAY TANK PLAN WvADDED SCREEN PLANINGS®TANKS GM J(iL I5� � Bwuun� SAN RMSEDAS PER SCHD COMWNTS GEH�1Q}12016 ____------ ------_-___.__ 1 I — i i i �7 r�v Level PRaee sNAu eelaw.iort w Rwve ns HwR Lwav is m waw+ � -' I > -........ n_._—......_., _ .-._._.c x.ewn/•mn�...,.. - _ __ � uPiinv"w m rA _ ... . _ -..... ..T' ••--.-. ,.-........-, - - _ .._. ...,. ., ti - _.. ...- vewr w _ 3 .--__-_—_ ______ ' i awDen.^:eoen�nrr , , PERhHT ACQUISITION AND EXPEDITERS MICHAEL DUNN, R.A. arH�.,OH,RY.�aRRb,2Nr nrr \ 1961 UNION BLVD BAYSHORE, NY 11706 7 i I I L Dax seALsa ra •.n++non seas.raga !i (631) 665-9619 FAX 969-0115 lA.­LP , xLo1mARY e.l—g—yLNx j i I �' Y eGLLY erle arouse S AAuou PnusPiu Dox I i •ENNRONMIII CCMPLIANCE 111011 SPECIALISTS R Hagmsontla.i suLeP ro rwrc TOP •COMMERCIAL SITE PLANNING 'PERMIT E%PEDITING I PRPv.Rr vDn r , n �� •e e ---�-----------------------� " PEGONIG LANDING i •-1 - y _f Y.URRnox eRa9 r sna.LY sne J p[RL I T I 1500 ROAD GREENFORT,NY 114ns ^D4 10Wl 1 I �`1""•� TNi I '1 PRELECT DESCRIPTIONSHEET DESCRIPTION Doul m W,[ I V ssaMorl'— Tiuc P I p I `i GENERATOR FUEL TA1UC5 DAY TANK B,G 8 D i x. gg GV.ESD eN. I stump I; I i L'----J � APPROVALS - �IC CiP w GY_ 11 w D•rHGK rG YAe w U o 6oi M a m�mrte �---------------- ------J fixe roro rea+ucoo exTer�xo�w u ee':oI'�m Ie'Iw1.rRPl`in T,`"'�1 I ALL rA+K EOeA�i �T.Vz-0YAH� °09 Ee a wILN Vit 1 x�PYane 56wIID'Aa�Y rAN[ ' TAK YAPS - 1000-35-OI-25 AI'u°c su SCALE _ - AS INDICATED Dw R 160803 710 GALLON DIE5EL DAY TANK ELEVATION (MFG 5Y TRAMONT MFG,LLC) DAY TANK 5112E G ELEVATION OflANN BY CBY GFH NI6 SLALE.1/3•=1-O' SCALE.I/]'.I-O' DATE SNEET 9/12/16 x i lD—#;4 n0F4 t Power Generation Specification sheet Diesel Generator Set QS137 Serie engine t 100-200 kW 60 Hz Description Cummins Power Generation commercial Control system -The PowerCommand®1.1 generator sets are fully integrated power electronic control is standard equipment and generation systems providing optimum provides total genset system integration including performance,reliability and versatility for automatic remote starting/stopping,precise stationary standby and prime power frequency and voltage regulation,alarm and status applications. message display,output metering,auto-shutdown Features at fault detection and NFPA 110 Level 1 compliance. The optional PowerCommand 2.2 Cummins®heavy-duty engine -Rugged 4- control is UL 508 Listed and provides AmpSentry'" cycle, industrial diesel delivers reliable power, protection. low emissions and fast response to load Cooling system -Standard integral set-mounted changes. radiator system,designed and tested for rated Alternator-Several alternator sizes offer ambient temperatures,simplifies facility design selectable motor starting capability with low requirements for rejected heat. reactance 2/3 pitch windings,low Waveform Enclosures-Optional weather protective and " —distortion•distortion witfr non-linear loads and fauit�� sound -enclosures are available. clearing short-circuit capability. . _ NFPA-The genset accepts full rated load in a single step in accordance with NFPA 110 for Level 1 systems. Warranty and service-Backed by a comprehensive warranty and worldwide distributor network. Standby ratin Prime rating Continuous rating Data sheets 60 Hz 50 Hz 60 Ha 50 Hz 60 Hz 50 Hz Model kW(kVA) kW(kVA) kW(kVA) kW(kVA) kW(kVA) kW(kVA) 60 Hz 50 Hz DSGAA 100 125 far;. 3 t5," 90 113 ? ,t' r: "(� I ,,r':.;tir.-:t_y; .t_.::ss='.. D-3349 DSGAB trb.g s Yew vhn, >3°,vt:��;t`' v.,{" i"i,=„ ;c 125 156 s r_r;r- 113 141 .' D-3350 DSGAC135 169 D-3351 DSGAD 175 219 160 200 D-3516 200 250 ;AKN.=:k: .r4 a 4�,5' i. wG' j .:: D-3517 WeeM&M ® cumminspower com 02015 Cunmins Power Generation Inc 13-1544n(3/15) Generator set specifications Governor regulation class ISO 8528 Part 1 Class G3 Voltage regulation,no load to full load t 1 Random voltage variation t 0.5% Frequency regulation Isochronous Random frequency variation t 0.25% Radio frequency emissions compliance I Meets requirements of most industrial and commercial applications Engine specifications Bore 107 mm(4.21 in) Stroke 124.0 mm(4.88 in) Displacemer)t 6.69 L(408 in) Configuration Cast iron,in-line,6 cylinder Battery capacity 1100 amps minimum at ambient temperature of-18°C to 0°C 0°F to 32° Battery charging alternator 100 amps Starting voltage 12 volt,negative ground Fuel system Direct injection:number 2 diesel fuel,fuel filter,automatic electric fuel shutoff Fuel filter Single element,10 micron filtration,spin-on fuel filter with water separator Air cleaner type Dry replaceable element Lube oil filter type(s) Spin-on,full flow Standard cooling system High ambient radiator Alternator specifications Design Brushless,4 pole,drip proof,revolving field _ Stator 2/3 pitch Rotor Single bearing,flexible discs Insulation system Class H Standard temperature rise 150°C standby at 40°C ambient Exciter type Torque match(shunt)standard,PMG optional Phase rotation A(U),B(V),C(M Alternator cooling Direct drive centrifugal blower fan AC waveform total harmonic distortion <5%no load to full linear load,<3%for any single harmonic Telephone influence factor(TIF) <50 per NEMA MG1-22.43 Telephone harmonic factor(rHF) <3 Available voltages 1 60 Hz Three phase line-neutral/line-line l 60 Hz Single phase line-neutral/line-line • 110/190 • 115/230 Delta • 127/220 •240/416 110/220 •115/230 9 120/240 • 110/220 • 120/208 1 • 139/240 •255/440 • 115/200 9 120/240 Delta • 220/380 •277/480 • 230/400 •347/600 not available with DSGAD or DSGA Note:Consult factory for other voltages. Generator set options and accessories Engine Alternator Exhaust system ❑ Remote annunciatgr panel ❑ 120 V 150 W lube oil heater lif 105°C rise ❑ Heavy duty exhaust elbow ❑ Spring isolators Wf 120A 40 V 1500 W coolant ❑ 125°C rise ❑ Slip on exhaust connection ❑ 2 year prime power warranty heater ❑ 120 V 100 W anti- Generator set N( 2 year standby power Fuel System condensation heater ❑ Battery warranty ❑ 24 hour sub-base tank PMG excitation Cf Battery charger ❑ 5 year basic power warranty (dual wall) ❑ Single phase lit Enclosure:aluminum,eleei- sound attenuated fit Main line circuit breaker Note:Some options may not be available on all models-consult factory for availability. Our semW' herr cumminspower.com 02015 Cummins Power Generaton Inc. I S-1 544n(3/15) Control system PowerCommand 1.1 Alternator data • Line-to-line and line-to-neutral AC volts •3-phase AC current • Frequency •Total kVA 0 Engine data a (4;Oi • DC voltage • Lube oil pressure • Coolant temperature • Engine speed PowerCommand control is an integrated generator Other data set control system providing voltage regulation, engine . Genset model data protection,operator interface and isochronous • Start attempts,starts,running hours governing(optional).Major features include: • Fault history • Battery monitoring and testing features and smart • RS485 Modbus®interface starting control system. • Data logging and fault simulation(requires InPower •Standard PCCNet interface to devices such as service tool) remote annunciator for NFPA 110 applications. Digital governing (optional) •Control boards potted for environmental protection. • Control suitable for operation in ambient • Integrated digital electronic isochronous governor temperatures from-40°C to+70°C(40 OF to •Temperature dynamic governing +158 °F)and altitudes to 5000 meters(13,000 feet). Digital voltage regulation • Prototype tested;UL,CSA,and CE compliant. • Integrated digital electronic voltage regulator • InPower"PC-based service tool available for a 2-phase line-to-line sensing detailed diagnostics. • Configurable torque matching Operator/display panel Control functions • Manual off switch .Time delay start and cooldown •Alpha-numeric display with pushbutton access for e Cycle cranking viewing engine and alternator data and providing . PCCNet interface setup, controls and adjustments(English or o (2)Configurable inputs international symbols) • (2)Configurable outputs • LED lamps indicating genset running,not in auto, • Remote emergency stop common warning,common shutdown, manual run . Glow plug control(some models) mode and remote start •Suitable for operation in ambient temperatures from Options -20°C to+70°C ❑ Auxiliary output relays(2) • Bargraph display(optional) ❑ 120/240 V;100 W anti-condensation heater AC protection ❑ Remote annunciator with(3)configurable inputs and • Over current warning and shutdown -r (4)configurable outputs • Over and under voltage shutdown 9 PMG-alternator excitation . • Over and under frequency shutdown _. ❑ PowerCommand Watch web server for remote • Over excitation (loss of sensing)fault monitoring and alarm notification (loose) • Field overload ❑ Auxiliary,configurable signal inputs(8)and configurable relay outputs(8) Engine protection 6(Digital governing • Overspeed shutdown ❑AC output analog meters(bargraph) • Low oil pressure warning and shutdown - Color-coded graphical display of: • High coolant temperature warning and shutdown - 3-phase AC voltage • Low coolant level warning or shutdown - 3-phase current • Low coolant temperature warning - Frequency • High, low and weak battery voltage warning - Wa • Fail to start(overcrank)shutdown ❑ Remote operator panel • Fail to crank shutdown ❑ PowerCommand 2.2 control with AmpSentry • Redundant start disconnect • Cranking lockout protection •Sensor failure indication For further detail see document S-1531. • Low fuel level warning or shutdown • Fuei-in-rupture-basin warning or shutdown OEW emerwwasm"ftr-a-- cumminspow er.com 02015 Cummins Power Generation Inc. I S-1 544n(3/15) Ratings definitions Emergency standby power(ESP): Applicable for supplying power to varying electrical - -- - load for the duration of power interruption of a reliable utility source.Emergency Standby Power(ESP)is in Dim°s• accordance with ISO 8528. Fuel Stop power in accordance with ISO 3046,AS 2789, DIN 6271 and BS 5514. Limited-time running power(LTP): Applicable for supplying power to a constant electrical -r load for limited hours. Limited Time Running Power Dim"c• (LTP)is in accordance with ISO 8528. Prime power(PRP): o Applicable for supplying power to varying electrical 1 load for unlimited hours. Prime Power(PRP)is in accordance with ISO 8528.Ten percent overload Dim•A^ capability is available in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514. Base load (continuous)power(COP): This outline drawing is for reference only. See respective model data sheet for specific model outline drawing number. Applicable for supplying power continuously to a constant electrical load for unlimited hours.Continuous Do not use for installation design Power(COP)in accordance with ISO 8528, ISO 3046, AS 2789, DIN 6271 and BS 5514. Dim"A" Dim"B" Dim'rC" Set Weight* Set Weight* Model mm(in.) mm(in.) mm(in.) dry kg(lbs) wet kg(lbs) DSGAA 2656(104.6) 1100(43.3) 1549(61) jyyf 1180(2602) DSGAB 2656(104.6) 1100(43.3) 1549(61) i? ` 1225(2700) DSGAC 2656(104.6) 1100(43.3) 1549(61) 1263(2784) DSGAD 2656(104.6) 1100(43.3) 1549(61) ; ` °, 1361 (3000) DSGAE 12656(104.6) 1100(43.3) 11549(61) 1361 (3000) *Note:Weights represent a set with standard features. See outline drawings for weights of other configurations. Codes and standards Codes or standards compliance may not be available with all model configurations-consult factory for availability. This generator set is designed in facilities The generator set is available listed to certified to ISO 9001 and manufactured in UL2200 UL 2200. facilities certified to ISO 9001 or IS99002. The Prototype Test Support(PTS)program Engine certified to Stationary Emergency U.S. verifies the performance integrity of the generator EPA New Source Performance Standards, set design. Cummins Power Generation U.S. EPA 40 CFR 60 subpart IIII Tier 3 exhaust emission products bearing the PTS symbol meet the levels. U.S.applications must be applied per prototype test requirements of NFPA 110 for this EPA regulation. Level 1 systems. The generator set package is available certified All low voltage models are certified to CSA International for seismic application in accordance with the CSA C22.2 No.100 and CSA C22.2 No.14. Building following International Building Code: Code IBC2000,IBC2003 IBC2006,IBC2009 and IBC2012. Warning:Back feed to a utility system can cause electrocution and/or property damage.Do not connect to any building's electrical system except through an approved device or after building main switch Is open. North America 1400 73rd Avenue N.E. Minneapolis,MN 55432 USA Phone 763 574 5000 Fax 763 574 5298 PowerGeation Ow worklinp farvou.; ce 092015 Cummins Power Generation Inc All rights reserved Cummins Power Generation and Cummins are registered trademarks of Cummins Inc PowerCommand,AmpSentry,InPower and"Our energy working for you"are trademarks of Cummins Power Generation Other company,product,or service names may be trademarks or service marks of others"Specifications are subject to change without notice" Cummlnspo F:encom S-1544n(3/15) Model: DSGAE Frequency: 60 Fuel type: Diesel KW rating: 200 standby 180 prime Elrissions jewel: EPA HSPS Stationary Er, eergency Tier 8 'r L 4 Exhaust emission data sheet: EDS-1124 Exhaust emission compliance sheet: EPA-1173 Sound performance data sheet: MSP-1102 Cooling performance data sheet: MCP-210 Prototype test summary data sheet: PTS-285 Standard set-mounted radiator cooling outline: A035C611 Optional set-mounted radiator cooling outline: " �rysA.+`Lg:; tl'ti°r',a wSb'r( jt S^z.i€'F �n 9'131 ? '�. a+;z ":'�.a:. :4� .s.%s", .'.srf,,. exs�'ns,;.':�,..'�._cr�t�„��e:G1`, l h i O tonaeat exchangercoolin outline: P9 .i: errs•sit n :�. ?c .�:.. _�' Optional remote radiator cooling outline: Fw5'ta=i" ?.� � r'r "�' �.�>`,tr .rL .uD3:riU r 1 ar ai)aJ_. Ya_421i1 a�t4 ar{is ivi:. Standby Prime Continuous Fuel consumption kW(kVA) kW(kVA) kW(kVA) Ratings 200(250) 180(225) E `'t�i;+`'��' 1'r", ''6 'p�'•; Load 1/4 1/2 3/4 Full 1/4 1/2 3/4 Full Full US gph 5.20 8.67 11.63 14.79 4.79 8.16 10.81 13.36 qr. ��r'; F a,);ti.a+i`t�Y L/hr 19.7 32.8 44.0 56.0 18.1 30,9 40.9 50.6JK .;'x ; 1 ?` �'?,''+f Standby Prime Engine rating ratingContinuous rating Engine manufacturer Cummins s KIWI, Engine model QS67-G5 NR3 ?���;�= �°`"i•u'`' Configuration Cast iron,in-line,6 cylinder Lcir :,4? L4`ty ,.Y1 Aspiration Turbocharged and air-to-air aftercooled Gross engine power output,kWm(bhp) 242 324 208 279 'i i `t y`?c BMEP at set rated"(oad,Oa'(ps) '`x 2255'(327) 2033(295) Bore,mm(n) - 107(4.21) Stroke,mm(in) 124(4.88) Rated speed,rpm 1800 "xi'''°' "z ;` Piston speed,m/s(ft/min) 7.4(1464) Compression ratio 17.2:1 Lube oil capacity,L(qt) 17.5(18.5) 4'x ' ` Overspeed limit,rpm 2100 "a'�:, Regenerative power,kW 19 Fuel flow Maximum fuel flow,Uhr US gph 106(28 to .-< rtw •s; „ :.:. ., f' t^ Sw,.?rit., S;C<' s'� i T'r "+:.� Maximum fuel flow with C174,Uhr(US gph) `n:.':'!::F:._�;.`�.�) :a`>�-�!:->�;a�C•,y :�"� .�z��' .;:�.x„ ?(�;:„�-�':(tz�ri �.:.s;:� Maximum fuel inlet restriction with clean filter,mm Hg(In Hg) 127(5) Maximum return restriction,mm Hg(In Hg) 152(6) 02011 Cummins Power Generation Inc All rights reserved Cummins Power Generation and Cummins are registered trademarks of Cummins Inc."Our energy working for you."is a trademark of Cummins Power Generation Specifications are subject to change without notice. D-3517(8/11) Standby Prime Continuous rating Air rating rating Combustion air,m'/min(scfrn) 15.8(557) 15.3(539) Maximum air cleaner restriction with clean filter,kPa(in H2O) 3.7(15) Alternator cooling air,m3/min(cfm) 41.3(1460) 'Cl Eli,4�A- Exhaust Exhaust flow at set rated load,m'/min(cfm) 40.5(1428) 37.7(1332) gall Exhaust temperature,0 C(0 F) 510(949 484 903) Maximum back pressure,kPa(in H2O) 10 40 10(40) Standard set-mounted radiator cooling Ambient design,**C(*F) 50(122) -M,-2 Fan load,kW.(HP) 9.7(13.0) Coolant capacity with radiator),L(US Gal) 23(6.1) 23(6.1) Cooling system air flow,m3/min(scfm) 351 12400 LINK-IITICA"'L Total heat rejection,MJ/min(Btu/min) 9.90(9376) 8.95(8481) Maximum cooling air flow static restriction,kPa in H, 0.12(0.5) Optional set-mounted radiator cooling Ambient desi K W qn, *G(*F) Fan load,W.(HP) Coolant capacity(with radiator),L(US Gal.) xkp-�-Y3—MMINEWM E Cooling system air flow,m3/min(scfm) Total heat rejection,MJ/min(Btu/min) Maximum cooling air flow static restriction,kPa(in.H, Optional heat exchanger cooling _R-1 X11 Set coolant Capacity,L(US Gal.) Heat rejected,jacket water circuit,MJ/min(Btu/min) Heat rejected,aftercooler circuit,MJ/min(Btu/min) ae��,s 110 Heat rejected,fuel circuit,MJ/min(Btu/min) Total heat radiated to room,MJ/min(Btu/min) sv� Maximum raw water pressure,jacket water circuit,kPa(psi) !,� Maximum raw water pressure,aftercooler circuit,kPa(psi) 7—T, Maximum raw water pressure,fuel circuit,kPa(psi) U , Maximum raw water flow,jacket water circuit,Umirl(US Gal/min) IRIIPW-R��-* �KR--MRTV,5-T �4��PR"5-7, :,T Ka Maximum raw water flow,aftercooler circuit,Umin(US Gal/min) Maximum raw water flow,fuel circuit,Umin(US Gal/min) MinimUm raw water flow at'27'C-(80'*F)inlet temp,jacketwater circuit, Umin(US Gallmin) !k,- Minimum raw water flow at 27*C(80*F)inlet temp,aftercooler circuit, F U Umin(US GaVmin) Minimum raw water flow at 27 OC(80*F)inlet temp,fuel circuit, Umin (US GaVinin) i-u Raw water delta P at min flow,jacket water circuit,kPa(psi) Rawwater delta P at min flow,aftercooler circuit,kPa(psi) Raw water delta P at min flow,fuel circuit,kPa(psi) Maximum jacket water outlet temp, *C(*F) Maximum aftercooler inlet temp. OC(*F) Maximum aftercooler inlet temp at 25'C(77'F)ambient, *C *F) 1111-1�11V:�� R�M Our energy working for you:M www cumminspower.com 02011 Cummins Power Generation Inc All rights reserved.Cummins Power Generation and Cummins are registered trademarks of Cummins AdWU Power Inc."Our energy working for you.'is a trademark of Cummins Power Generation Specifications are subject to change without notice Generation D-3517(8/11) fto. Optional remote radiator cooling' Standby Prime continuous rating rating rating Set coolant 7 caP `aci{��.L(US gal) r&i, <�any r:1 ,.,;�.•.;,,,�r. ,R,, ,z,,, °t SRx`_s.`:.MG-e:?i�t'•'e':.c`.ii ,.n n-i..o;+..,'r.,:::...!5:.,".e.��.-..:..rr„a.:,;7'.-i 4?D�.t.•,. Max flow rate at max friction head,jacket water circuit,Vmin US �`v.Cb: ? "+' al/minJd s�ctc�'Sci�wil 'Li.?°�'f`ik?� ':�~a :% cw.a,eb ° x;t7ju ': s. Max flow rate at max friction head,aftercooler circuit,Umin(US " �g` Q�'rr tx C 1 fS'a�'E :}•y1F .f �'14w`�'. al/min r ,�.}a A t. ,�rr, �rzf• e � '. �,',' 7'- ' �• s ii,: !frT: s 1t,rat' ca: r i.t �1F Heat rejected,jacket water circuit,MJ/min(/Btu/min 'r� { ` �` "�" z+ � � ` � �<`' °1tf 7' J ,J (Btu/min) �rr.`�.�z:i�c+vZLA-.•L�S!_Y)u.�..mxLaa.• rt.Zu�+��x+/ al�'Ss. Y a-..N253".!F v, Heat rejected,aftercooler circuit,MJ/min(Btu/min) Mw'_ ��� s �`�„�Yll; z { " tT(r p ( 1 si; Heat rejected,fuel circuit,MJ/min(Btu/min) v 3 QX'11I " _%k1�1_01 1?„eTa31• arN1lk"B'^N Total heat radiated to room,MJ/min(Btu/min) Maximum friction head,jacket water circuit,kPa(psi) iMil '�i"^car•, a �Y �>,� 5rr�,va spa-pt �vf. t� 4? „ Maximum friction head,aftercooler circuit,kPa(psi) �t,�i�,��;�•i;.,> � ":;�,. :,r,;�,*;�,��,s��...; �`�,,,�4:�=.,��;,_ Maximum static head,jacket water circuit,m(ft) ' ; Maximum static head,aftercooler circuit,m(ft) `� r ;x. a ? e ?� �•,. Maximum (� tem water outlet jacket ,°C �s rx ^ •;� "_"7 .$� , , w J P :frri�4;,:. a..•t:.:i a,.. xc .i�s.�:"ff�"s, 'Sr' � Maximum aftercooler inlet temp at 25°C(77°F)ambient,°C(°F) `� ' #t? ai{ c��*- i Maximum aftercooler inlet tem °C Maximum fuel flow,Uhr(US gph) Maximum fuel return line restriction,kPa(n Hg) Weights2 Unit dry weight kgs lbs. Unit wet weight kgs(lbs.) 1361 3000 Notes: 'For non-standard remote installations contact your local Cummins Power Generation representative. 2 Weights represent a set with standard features. See outline drawing for weights of other configurations. Derating factors Engine power available up to 1707 m(5600 ft)at ambient temperature up to 40°C(104°F)and 732 m Standby (2400 ft)at 50°C(122°F). Consult your Cummins Power Generation distributor for temperature and ambient requirements outside these parameters. Engine power available up to 1707 m(5600 ft)at ambient temperature up to 40°C(104°F)and 732 m Prime (2400 ft)at 50°C (122°F). Consult your Cummins Power Generation distributor for temperature and ambient requirements outside these parameters. fes.'k "e 't qq x bra 1ir'�e°'y'i +rs•�r, �.c a i t. 't. E WAR ''"r �'•t .:i jY �k`F�N�`v �S� �,) •Yu+• w tt `fir qw .E'.. y°': � ]"-$ 3 °Z9 ^ •t u`�•=7 tki'`. x W i '`4 °'i•;;v' Continuous �..:=3 ;t, ? fi? d. zti� t �£_ ar. � r �, r r�' y .� •avdK,; i �. n y a. , • �' i�Srf .°:6,'.�i. :°-•.ter R' _%'f5.£i•f° :aiS0.?' :w»`r' _ "i"2.stz+...: �,�'t. ^.' iti�x3;i'7S.? Ratings definitions" __ Y Emergency standby power Limited-time running power Prime power(PRP): Base load(continuous) (ESP):- (LTP): power(COP): Applicable for supplying power to Applicable for supplying power Applicable for supplying power Applicable for supplying power varying electrical load for the to a constant electrical load for to varying electrical load for continuously to a constant duration of power interruption of a limited hours. Limited Time unlimited hours.Prime Power electrical load for unlimited reliable utility source.Emergency Running Power(LTP)is in (PRP)is in accordance with ISO hours.Continuous Power(COP) Standby Power(ESP)is in accordance with ISO 8528. 8528.Ten percent overload is in accordance with ISO 8528, accordance with ISO 8528.Fuel capability is available In ISO 3046,AS 2789,DIN 6271 Stop power in accordance with accordance with ISO 3046, and BS 5514. ISO 3046,AS 2789,DIN 6271 and AS 2789,DIN 6271 and BS 5514. BS 5514. Our energy working for you:m www cumminspower.com ©2011 Cummins Power Generation Inc All rights reserved.Cummins Power Generation and Cummins are registered trademarks of Cummins Power Inc."Our energy working for you."is a trademark of Cummins Power Generation.Specifications are subject to change without notice Generation D-3517(8/11) Alternator data Three Phase Table' 105'C 105'C J10WC 125'C 125'C 125'C I 150°C 150'C 150'C Feature Code 8418 B415 B304 B417 8414 B303 8416 8413 B419 Alternator Data Sheet 212 212 212 212 212 212 211 211 211 Number Voltage Ranges 110/190 120/208 347/600 110/190 120/208 347/600 110/190 120/208 347/600 Thru Thru Thru Thru Thru Thru 120/208 139/240 120/208 139/240 120/208 139/240 220/380 240/416 220/380 240/416 220/380 240/416 Thru Thru Thru Thru Thru Thru 240/416 277/480 240/416 277/480 240/416 277/480 Surge kW 1212 212 215 212 212 215 212 205 214 Motor Starting kVA(at Shunt 770 770 770 770 770 770 672 672 672 90%sustained voltage PMG 1920 920 920 920 920 920 791 791 791 Full Load Current - 120/2013 1127/22 139/240 220/380 240/416-254/440 277/480 347/600 Amps at Standby 694 656 602 380 347 328 301 241 Rating 'Single phase power can be taken from a three phase generator set at up to 2/3 set rated 3-phase kW at 1.0 power factor. Formulas for calculating full load currents: Three phase output Single phase output kW x 1000 kW x Single Phase Factor x 1000 Voltage x 1.73 x 0.8 Voltage Cummins Power Generation 1400 73d Avenue N.E. Minneapolis,MN 55432 USA Telephone:763 574 5000 Fax:763 574 5298 Warning: Back feed to a utility system can cause electrocution and/or property damage. Do not connect to any building's electrical system except through an approved device or after building main switch is open. Our energy working for youTM" www.cummoisr)ower.com 02011 Cummins Power Generation Inc.All rights reserved Cummins Power Generation and Cummins are registered trademarks of Cummins Power Inc "Our energy working for you."is a trademark of Cummins Power Generation Specifications are subject to change without notice Generation D-3517(8/11) e