Loading...
HomeMy WebLinkAbout41152-Z %gfFDtl/(, Town of Southold 12/11/2017 0 P.O.Box 1179 co 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39399 Date: 12/11/2017 THIS CERTIFIES that the building GENERATOR Location of Property: 1205 Route 25, Greenport SCTM#: 473889 Sec/Block/Lot: 35.4-25 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/27/2016 pursuant to which Building Permit No. 41152 dated 11/10/2016 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ACCESSORY COMMERCIAL GENERATOR(FOR APT BLDG#1), AS APPLIED FOR The certificate is issued to Peconic Landing @ Southold of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 41152 12-06-2017 PLUMBERS CERTIFICATION DATED Authorized Signature a��Frot�oTOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41152 Date: 11/10/2016 Permission is hereby granted to: Peconic Landing @ Southold 1500 Brecknock Rd Greenport, NY 11944 To: install generator as applied for. At premises located at: 1205 Route 25, Greenport SCTM # 473889 Sec/Block/Lot# 35.-1-25 Pursuant to application dated 10/27/2016 and approved by the Building Inspector. To expire on 5/12/2018. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO -ACCESSORY BUILDING $50.00 Total: $235.00 B it ctor Form No_6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of.Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: 1�� �`�K-b C � P -o4 House No. Street /, rlet Owner or Owners of Property: �G Suffolk County Tax Map No 1000,Section Block Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted:$ Applicant;111t ure pF SOU��®! Town Hall Annex Telephone(631)765-1802 54375 Main Road s/a Fax(631)765-9502 P.O.Box 1179 �� roper.rich ert(D-town.southold.ny.us Southold,NY 11971-0959 c®l6NTY,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To. Peconic Landing @ Southold Address: 1205 Route 25 city Greenport st: New York zip: 11944 Building Permit#: 41152 Section 35 Block 1 Lot: 25 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: M. Turza Electric License No: 41858-ME SITE DETAILS Office Use Only Residential Indoor Basement Service Only Commerical X Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures HID Fixtures Service 3 ph X Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: "APT" Building #1" Notes: 200 KW Generator with Auto Transfer Switch and Disconnect- 3 Phase. Inspector Signature: Date: December 6, 2017 0-Cert Electrical Compliance Form.xls FIELD INSPECTION REPORT7 DATE COMMENTS FOUNDATION (1ST) �- y --------------------------------- FOUNDATION (2ND) • z o, ROUGH FRAMING& y PLUMBING INSULATION PER N.Y. ' STATE'ENERGY CODE FINAL ADDITIONAL,COMMENTS (C�' 11- c( tiro C — z • � rn 1 � z b H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CH>}CKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502Survey SoutholdTown.NorthFork.net PERMIT NO. r —7' Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application /m_ Flood Permit Examined ,20 D Single&Separate Storm-Water Assessment Form '0 CT 2'� 2016 Contact: 'Approved 204 •Disapproved,a/,c. —j -•: BUMDING.D ' TOWN OF SO D 2V- W iaf M C0116 ' Phone: Expiration ,20 (�n�l Buildin actor APPLICATION FOR BUILDING PERMIT Date , 20 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to-the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has-not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of a icant or name,if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises (Aso the tax roll or latest deba) 1.t' pplicant is a corporatioi signature of duly authorized officer iA 5 0 t 4060(Name nd title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which posed work will be e: 00 1 6R&,k1& House Number Street '- - Hamlet s' v n- .y\ `ria:•. >„J a='1Y x§,}.,�? County Tax Map No. 1000 Section S Block e 1" ty✓ its F:l 4 1•li•:! 9 4. ... f�t Subdivisfori Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and 'occupancy b. Intended use and occupancy 3. Nature of work.(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work '-ot., (Description) 4. Estimated Cost ° Fee,. „.,t_ ,_.__ Cpar� a=fioJ .fl r=; F:(To be paifi d filing this application) 5. If dwelling, number of dwelling units mber of dwelling`Gnits'ontieach floor If garage, number of cars I d 4 4i-a jCS1 (u I 7 Y u i. 1 j r� 6. If business, commercial'or mixed occupancy, specify nature and extent of each type of use. Ccw1+i&i 0 _a r-t 2—It Q (7 Dimensions of existing structures, if any: Front -. r : -Rear'"_ ' Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories (91 Size of lot: Front Rear Depth 10. Date of Purchase 1 9 9 7 Name of Former Owner i 11. Zone or use district in which premises are situatedy; 11g'ce *E C Ott 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO V 13. Will lot be re-graded? YES NO \e�Will excess fill be removed from premises? YES NO 14. Names of Owner of premises Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No'. - / 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetfand? *YES NO V * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO' * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale;.with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OFC r R(bu+ ron being duly sworn, deposes;and says that(s)he is the applicant (Name of indivi&tA signing contract)above named, (S)He is the Rt'r Sa e'-C.vA_ u.n.41 C e U (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this _2 day of O gA-o6-GT--1�4 Z::lG.Catmll otaryPublicQwhfiedinSut'olc Signa of Applicant No.OICA5009515 C mmission Expires April 29,20-" PERMIT TO CONSTRUCT Toxic and/or Hazardous Material Storage Facility Suffolk County Department of Health Services JAMES L. TOMAKEN, MD, MPH,MBA, MSW Commissioner SCHDS REFERENCE# 09714 Date of Issuance: November 10,2016 SCHDS REGISTRATION# 10-0195 Permit Expiration Date: November 10,2017 SCHDS PLAN# M116-161R1 -'`FACIL�ITY,NAME-- i:ADDRESS'-',-,�- `Peconic.Landing-at S,outholil='` ' 1500`'BrecknockRoad •- '' Greenport,N.Y.,11944', Your Application for Permit to Construct,a Toxic or Hazardous Material-Storage Facilities for the•abgve referenced site has,beep"ievieWed.for compliance with Arricles '7&'12 of'tlie'Suffolk County Sanitary-,Code. `The;application has beeri approved.The items listed,below'•and on the back of this Permit are conditions of this,Peri i"p`d'have to be observed*during construction: 1. . A copyfof the:approved plan must be kept at the construction site. A copy of�this'permit`must betkept;on dispthe lay,at- facility during construction. ss' 2. Safeconstruction practices''must be followed during the installation of the storage-facility(s).; 3. . The storage facility(s) must`Ybe constructed',iii-accordance with the approved plan; Any•changes'in„ ; design,-.materials-or use require=prior':wrrtten'consent`of both,the"design professionalrgand..tlie•Office Pollution:Control. The chatl'ges,Aave,to ne':"submitted iti-a form that is acceptabldijo;the�,Office of; Pollution Control. The contractor=="aricUor;design-.professional is vequired to inform the ownei-that the; r/ .,.! -:�,'• fir. t•;;':" l� n.y-'= �.'ti� ch "ges;are being made. '4. The Office of Pollution Controb,,,O s',thez right,to inspect this'installation at any time to veriN-its being` constructed in compliance with this,-permit.-.'- The his,permit.. _The Office of Pollution-'Control must be contacted-;at854=2523`af'leyasf 2-bu's`iness daysprior to commencement-oc dc',."' any work to arrange.•for the required construchoriinspections. :rs ,;;'. _' E,';�" Contact the local,buifding,department and/or fire safety,.enforcement.offceifor any additional'requirements that may-` apply-to your project. ° The sforage facility canriot;be placed=into service=.until the Uffice-W1P611ution-Control performs all_•reguired installation inspections and'`'i`ssues an interim permit to operate. ^z' The Offic@`ofPollution'Conirol'rese"rves-the right to revoke this,permit<as;allowable-byrlaw: ={:a`:r ,_ Alexander M. Santino;_,RE. -- Principal Public Health Engineer's;: Bureau of Environmental Engineering Division of Environmental Quality SUFFOLK COUNTY DEPT. OF HEALTH SERVICES ' APPLICATION. FOR PERMIT TO CONSTRUCT TOXIC/HAZARDOUS MATERIALS STORAGE FACILITY SITE 1 LOCATION INFORMATION Business Name Contact Person Physical Address Community State Zip Mailing Address rttfiffem om?hymweddress) Community State Zip 6 5vc� e-D C, rjP*_1C1 I 019 Phone NumberFax Number E-Mail Address TAX MAP NUMBER District I Section Block Lot STORAGE FACILITY OWNER INFORMATION Storage Facility Owner's Name Contact Person Mailing Address Community State Zip Phone Number Fax Number E-Mail Address PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT INFORMATION irm/Professional's Name Contact'Person �-4 t e,.w�L, f 4°� ms s"� .3 Mailing Address Community State Zip + Phone Number Fax"Number E-Mail Address y Scope of Article 12 work: (Check all that apply) Aboveground Tank Upgrade Existing Facility Piping and/or Dispenser Underground Tank Transfer Facility Vapor Recovery Drum/Portable Container Dry Bulk Storage Scope of Non Article 12 work: (Check all that apply) New building construction New sanitary system Addition to existing building Addition to existing sanitary system Renovation of existing building Upgrade of existing sanitary system No additional building work is to be done No sanitary work is to be done .".�t, �' "'''" ' '> ='f% pE?lZ°Ql=�ry : S; ;f��['�if '`, ',t *t-�- r ,. .. ,�_1,, ;,• ... •r �a`r'r'�.:%5:':s::-a:e�h:..:i...+,,a.t.._ a<�.. � .,.....�•._.:.ts! 7l�".-_:�' nx,"L s�ibK,�.K��'.�*'."�:- >F,. •� •Sn.m�.'s•:.._L_ MO l et+i. rv. i.:'• `'tlY+�Lv'�,.+.Y~,[�-'y/r�.v�� ..N.��... .. .�,r>,v"y..t j YV,::,.,r�R, . ♦ t't`P.}� ` ''9Y+.+§' TMt R:. _ y �•"tom• :±o.,L.:IP'•.•: i�+���2:.'.11m.-s `�l'....�r.i.t�t �/ ~���,�u11W} .5t�'.�'",ptt��,;-,1tt. ~ •� F� _• 'hY r. �;t ,.•4 -`•v.w •` ` _ y Yg .. ! .l.. K.aS P;. �t� �,�• •- t'�`Q�YJt•• gi '!1� yT�a R+M�N Yv! � 79`..v'lr Yr'S,'`'{ Yw 'r:: '.CT Yr• yY.}: k e C•'�.KCP:S„7<y.tr.` ..�,. . .. ` - x...� .e.{ .j.r . ::.. r t. ... ._•c-�.y. r.e wa `.ti:y, . +c.i:art;"'�'l ... 7'r. . „X- MO Rev 19'FCs c tt A. Fussell °�uFfia��� S F O�JE�.I��1 WAXIE)[, o VISOR NA\�G GEM LENT SUPER �, I��1[A�� SOUTHOLD TOWN HALL-P.O.Box 1179 �p 53095 Main Road-SOUTHOLD,NEW YORK 11971 'l Town of>S'o u th o l d CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOES 'd'IE-IIlS PROJECT INVOLVE ANY OF THE FOLLOWING: OWING: (CHECK ALL THAT APPLY) Yes No ( A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surf ace. ❑[:g/B. Excavation or filling involving more than.; 00 cubic yards ot!material within any parcel or any contiguous area. i t ❑ff C. Site preparation on slopes which exceed 19, feet vertical rise to 100 feet of horizontal distance. ❑dD. Site preparation within 100 feet of weli.laWs, beach, bluff or coastal i erosion hazard area. ❑[d E. Site preparation within the one-hundret d3eair f loodplain as depicted ❑don FIRM Map of any watercourse. `3 F. Installation of new or resurfaced impervious surfaces of 1;000 square feet or more, unless prior approval of a Stormwater Management i Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. S.C.T.M. #: 1000 Date- APPLICANT (Property Owner,Design Professional,Agent,Contractor,Other) District 9 —tet NAME U 0 6N � /D o�� I P i Section Block Lot i �,s�a,�«, IORBUILDING DEPAR'I�N�ll IN] c. �: ����_.; •.z Contact Information. rav,i- Nmol-„ . Reviewed By: AA Date. r�������� Property Address / Location of Construction Work: — — — — — — — — — — — — — — — — — ' Approved for processing Building Permit — — Stormwater Management Control Plan Not Required. p r L) 7 1r �1 Stormwater Management Control Plan is Required (Forward to Engineering Department for Review) i FORM 11 SMCP-TOS MAY 2014 APPLICANT: S.C.T.M. #: 1000 (Property Owner,Design Professional,Agent,Contractor,Other) — — 0- -y CHAPTER 236 Stormwater Management Control Plan CHECK LIST NAME Section Block Lot S M C P -Plan Re uirements: Provide ONE co of the Buildin Permit A lication. Yka+c Ynnl q PY g PP •Date: * The applicant must provide a Complete Explanation and/or Reason for not providing all Information that has been Required by the following Checklists I. A Site Plan drawn to Scale Not Less that 60' to the inch MUST YES NO NA If You answered No or NA to any Item, Please Provide Justification Herel show all of the following items: If you need additional room for explanations, Please Provide additional Paper. a. Location & Description of Property Boundaries b. Total Site Acreage. c. Existing -Natural & Man Made Features within 500 L.F. of the Site Boundary as required by§236-17(C)(2). d. Teat Hole Data Indicating Soil Characteristics&Depth to Ground Water. 0O� e, Limits of Clearing & Area of Proposed Land Disturbance. f, Existing & Proposed Contours of the Site (Minimum 2'Intervals) g. Location of all existing & proposed structures, roads, OOH driveways, sidewalks, drainage improvements &utilities. h. Spot Grades & Finish Floor Elevations for all existing & proposed structures. 1. Location of proposed Swimming Pool and discharge ring. 0�0 j. Location of proposed Soil Stockpile Area(s). 000 k. Location of proposed Construction Entrance/Staging Area(s). 0�0 I. Location of proposed concrete washout area(s). OO� M. Location of all proposed erosion&sediment control measures. 00� 2. Sto-mwater Management Control Plan must include Calculations showing that the Stormwater improvements are sized to capture,store,and infiltrate on-site the run-off from all impervious surfaces generated by a two(21 inch 000 rainfall/storm event 3. Details&Sectional Drawings for stormwater practices are required for approval. Items requiring details shall include but not be limited to: a, Erosion & Sediment Controls. �00 b Construction Entrance & Site Access. X00 c. Inlet Drainage Structures (eg,catch basins,trench drains,etc.) 0�0 d. Leaching Structures (eg. infiltration basins,swales,etc.) 1 0R FNGINFI-MING DEPARTMENT USE ONLY Additional Information is Required. Reviewed & I ® Stormwater Management Control Plan is Not Complete. Approved By. — — — — — — — — — — — — — — — — — — — — — — — — — Stormwater Management Control Plan is Complete. Date ❑ SMCP has been approved by the Engineering Department. FORM * SWCP Check List -TOS MAY 2014 Nov. 3. 2017 10:45AM No. 1139 P. 3 laF SQI/jy� ro To")42M Annex 41Telephone(631)765-1802 54875 Main Road 6 I� P.O.BOY 1179 roger.richerto t h sou o .n .us Southold,NY 11971-0959 BUMDING D&PARThffNT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: v- c,—, Date: ` Company Name: h I f Y(b Name- M1 of License No.: LlI g Address: (ab Gov q ur Phone No.: (Al` 531- 3(o cX (a I- 3 29 - dto15- JOSSITE INFORMATION: (*Indicates required information) `Name: Ptconic. ev)IdIo *Address: 104 *Cross Street: *Phone No.: _ o3l - q1 7- 5$oo Permit No.: 6? q 11.5 Tax-Map District: 1000 , Section; Block: 01 Lot: *13RItF DESCRIPTION OF WORK(Please Print Clearly) _ ,I/ ,r lee'netWov" - �v� owo lG4l`ZG (Please Circle All That Apply) Is job ready for Inspection: 2/ NO NO Roughs In Ffna! *Do-you meed a Temp Certificate: Temp Information (if,needed) *Service Size: 1 Phase Q2a 100 950 200 300 360 400 Other *New Service: Re-Canned Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION i 82-Request for Inspeoflop Form CHARLES R.CUDDY ATTORNEY AT LAW 445 GRIFFING AV ENUE RIVERHEAD,NEW YORK Mailinc Address: TEL: (631)369_8200 P.O.Boa 1547 FAX: (631)369_9080 Riverhead,•NY 11901 E-mail:eh&des.euddy@„erizon.net September 27,2016 Michael J.Verity,Chief Building Inspector Southold Town Building Department PO Box 1179 Southold,NY 11971 Re:Peeonic Landing at Southold,Inc.-Generators SCTM#1000 35-01-25 Dear Mr.Verity: This is to confirm my conversation with Heather Lanza,Planning Director of the Town of Southold concerning the proposed addition of three(3)generators and one(1)replacement generator,each of which sits on the slab 6 ft by 12 ft.and is used to supply emergency electricity to the nursing facility and apartments at Peconic Landing. Since the generators,as above described,do not impact any parking or cause disruption of services and are fully screened and are de minimis,Ms.Lanza indicated that no site plan is required. Very truly yours, N'�11. Charles R.Cuddy CRC/ik 52- h � 1 141 t tCP oo A I. Q. All /c!as 0 cle 4W is, bc I cl I aX f 100 L ./cic 4c! 4W rZ z /;K • 4? rl 10 10, % rW le rj F ILI' vp"', Al te, N25'50'14"W X IJMI-, OF a SLvt, I-Vi 4.40s Iric WETLANDS t ~`�\ F' ` `ij `�,\ ` ' SCENIC EASEMENT Z. ff 0 cl 0 A) 300.00' O U -Z4 4 Nr y POND WEILMUS x D1 WETLANDS ? Jt- HIM-2143 d- is o 131A 16.3 RIM-29 58 0 ww PAU0 I 1�� 44' wt i& ; ao 10 4- • I o8— 13,1B S I'll 16.2A.39 iR kf-22 3o .11.9 oc WIN 10 7 GAS N=28 SS RIM-27-67 RIM-29 60 °VALvE mm 4 wtzlu M13 V Q. MOO 43, R TA. 4m !35, W-0 MU It HHHX�01 I FUM-28.42 w 1,13.3 GT..13. C e, F13M 3�1 c H Un n 94!1.13.4 e 2IL78 o�a AAy L! j ss.8 StAH L 90 CIC CU#W.01 3 e LU RIM-M45 LJ AV tZ .79, IC ``'MH e ir 7, '�• I INSTALL(5)NEW TIO&A ON DYL 6EIERATOR DAY TAI.ICS + .ge"'- (AREAS B 6 4 D)1(U NET4 IA45 GALLON VA SENERATOR DAY TANK(AREA N AS PER PLAN PAOKPGE. 44 D.,'j' L FK,''�J>iY;4•:.nom!1'i r i-3)',',\.:.r..,,r:i' qy�+ 2 INSTALL NPY1 GREEN*I ARBORVITAES SURRO 'N6 �; -c .mow• TANKS AT AREAS B,L E D A9 11IDICATm HERCIN. }'?rif„`�^,�a(" { 'it¢f'��At µ&'sf✓ '� �r"'`c'`, c:. ,�,sl % -'•Orr!�,t •t-_'' B TEST ALL SYSTEMS IN ACCORDANCE YDTH SUFFOLK OCHRY s�a -� �CC'ar``'•`'",.�•3 j lL:'-"'"� ""4fi `.g :J{.:, S°". 1.1. 7 ;?i.`..`s :.3^ t'••;7 REGYIREI-mid • --�--_ „ '-•• \ � 4 RE5TORE ALL DISTIdtBED AREA$TO HATLN EKISTIN6 ` _. _..c,. •---.___•--.._-'- ; ` •� �/• 1 ' ,i7•y`^''-:-4'ue,. 'uA`.�.ryry���'`y,•"{ Lt�i .:•�=+� :;-y G�`; i I ,�� :�, {:Wi-j .�''_w..:'.:'!:' l yE,1 ,;.�4,,;x.!;-•:1a`•:• )'tF�,.`,.`.r'.•,,�a E.,,\•�,.: - _ TEBTINPsG L n] l s TESTNPRROInO -9 Psl wnARYi .�>f1 ,'"•.. ;'.;'"S'°i`'-•a,..`;.; ,;.$• ?�';'�'•.' z ••.A,.^.D. •�(.',.ti;.?•�f 2. NR TEST PIPING SB'ARATELY.PRRMRY PIPING AT'A PSI Nm p'"P=- ur.,, .• ;.,.<..�',,-,.;. 1 ` -..�a-'.i:: :.F ro '., + ..._.'t'..- 3 { ' ..fF.a;- .>.+,s y,�s1;i,.'•; Y, StIDAT 5P51.BOTHFOR MIW1ES, _ ?may t. ,yw•- 5 Au.TEST Esr To To e--reAS ra Lc L, rnre 1zF anl+�rAND EEesrAL '�@ t �g is,s h•.y ') f;g'}{°r 1 s"- �, f"�,w rs ;.✓.�,��: .-,y_.�w l�`, �.•;„tr..•trr T .Y,..> _d ``4'. fC„'.r''`•3 •vii`. I l nu: r"' t ,.::,:�+''r• ,.,�,:,;s'.; , s r4 `'.: ,.•. •`'rte,� O.ONTRAOTOR 1 -tis'�'>s?iI .,j ?r'-T1>•Q +: Y t rti%,' •-,. - - -•.._, ' NOTRU •A 4T J� rjj 's ,'lr -r` �.,} y I coermAeroR sNx1 e>wnrE THE slre 5, ••}'".IX •#13 ...1" _ }D+ �^ T• tt F -`,g' .,.` VERIFY ALL PIPINE Y�H TO Tl VIm TAN�K9�� #^:` J�Pt;''""'_?•el'.-R1ir. -:�. caw¢cnNt>PMNs PwoR ro n14e oP PRaPosED woR1c ';A `' .r"��•;';_' ` - . " '°''t% -t :.• ZONING DATA ' \y. .5fki�, ti .3. S';+�, i�Y ;f'1tr. d t r j`,.. _ �+yf�• ..,,.,.� ..._ ._... .. � 1 -ham '1.'s may` Y.�r( f j 'y„`•? I THE LRIL ATU Ct � �` 'S�I / ,!�"�•��}',�� ' r..e� �[ , I THe ewsrenrE Atm LocnnoN oP ANY DlIDERSIxp,Rm vrwn l r� • • _: - ••-�' '�•"" •Y�� ••„''>,ry _'r , PIPES.GOISV Il9 OR SIRIGTLRE9 M1 ON THEA RJJaS ARE PEGOHIGA _AT 50URtOLD.IMO P�OrT. tVLE TIA?S�MA�F�ATHEE1�,M NLOES ES ERECIN RD `tet r -' ' "~ ••.*1'K� �t', '-_r'Jj _ i ti- --}- nw2)oR-assloNs m THE L ,mAND oms WA=m of .L sr"TPeN°9 DENT.cEo `'.,' ,,.- l g Y,-'°'.her`��Q�� '`'j'=`( �'.•ei ti •t '• ! mu—A STRUCTURE 5X m -THE BEST OF A!R KNovamaE THERE ARE ra EwsT Y MJES E EPT ns sXom sreveN cNwaLL-rro ON TXEEE PLANS THE LOMRALTOR 15 REWIRED TO TAKE DUE 0,50 441AD00—4 PRECAUTIONARY I—IRES TO PRO'IELE THE UTILITY LDSS• IW PPLONKLMmINS_ I - , , - , H ON TIME DRAYIIN65 I ,G• �, A>,°�, ^,n,.p- '";;l;•4, :Y�'2T' ._ `r^t,'=•�" •ice ;`: �I TAX MAP INFORMATIONr AIR"ON `f,JIZA ,n, zT` !ww W,� •9 4 °. '•'"" i . ELEOTRIGAL MBTALLATIONB 1 --4„ R,.,,,ti r 1 'y,_,_'••" ,r .1 `y i i 1 ALL ELEOTRICAL ALALLAnoNs ntm EWIPl4T1P•sHOLLD �• ,,`' �•••. ) -:• L •,._ �zr 't - _ J+`Y _ +. -_-. _ , '� j 14F INSTALLED AND MNNTN NEPA TO, ATIOECTFUC Am OPEv ARTIOLE YDTN 514, 1 _ ° tr.•n , t n ` -` W of j' T I e , , - •-.L__ _ , j RI. S 2 YIVISOONDUIT AND WIRING FROM PROBES _ _� _y --. rrt.twro.' `•Y (� •t' G �"„_ ,.„..-_- •')' TO {' •% C,:r •� 4Y.fr•-C'�S''+ ^'';�L', _I- '¢t"_ I,pit +r'Fl*s-- !S})r'!f•h'--i"~l�1Y\�ll�x�v!•'•_6T,,�5",.�''" ``i'f ff .,,.�•�'} ,`i�I=I,a��`--_y`r-N, iI•(�_ y.- - � YNTMEORNPIRTOOROFPJ1RNCn°ON E'O%"ES_ IN DL L,_ R-M41 S—IO-+` PREUDYESINCPARLRANYNIIRDgNEJGSSIW®TANKS—Jr-CGFGHX` DALE 91220 16 - OWSTU92020164_ RO J DED SCRECN 1D102016AEMSED AS PER SOHD COYYENTS i Dr.' 10312016 --_-- ___ ,� i ' l'• r,• `c.�"s'yI• ,,.,t :� •_(� '�_�-^ 1,p✓, y' ,lit I�Y? .�,� � t__ , _�___—_--_ .ks , y"t\ L, 4yN• n d� r» -- -i------ '1• '.��G• "S> .G'-r-,�;•' N4.,�}'T„�N^�r .t�t S' _• \l �/: aa, ..J'�y i'� ". -7" oar :�::s6 S 1 1'l •%�„ p ----------------- - ----------I —--_—_ 1`+.P`^' i -..• -� ' "' _ __ I' , `•.-.,. PERMIT ACQUISITION AND EXPEDITERS MICHAEL DUNN, R.A. 1961 UNION BLVD BAYSBORE, NY 11706 (631) 665-9619 FAX 969-0115 _LAN— -__—___ �1 �4 -ENVIRONMENTAL COMPLIANCE -PETROLEUM SPECIALISTS -COMMERCIAL SITE PLANNING -PERMIT EXPEDITING PEGONIG LANDING 1500 SRECKNOCK ROAD &REENPORT,NY 11444 PROJECT DESCRIPRON SHEET DESCRWPON 6ENERP,TOR RA.TANKS 51TE PLAN t DETAILS APPROVALS • �"°6e a ��e4 n"d�0l1 �Pr TAX YAP/ 1000-55-01-25 SCALE A5 INDICATED D.g 160505 DRAWN BY CNN'D BY GFH I 6WG oAM SHEET 9 2/16 i D �IOF4 1 ys,r`,^lq''i•^ :tµ { {,rs e .i,�s;�ei.:'fs'I:'+c}' 'j�.-}•?'."i',.1 s x..;rv_ GRASS t GRAVp X'+ ,`._. :1`C�,;., '.4"� q•I.A,4�•, `.¢� :et',dJ'�`„`*�-,ti✓�'Y,f '-�» DIESE200"L GEN RATO"' / / ZONING DATA EXISTING 2-1/2 STY. UPONEWA 110 GALLON APARTMENT j/ DYl DAY TANK UPON CONTACT INFO BUILDING / '/•// GRASS NEA 8•THK GONG SLAB PEl,ONIG LANDING AT 5.<VIlA LD,MG, s eRDsnnac rm j � GIANT G��L 1`� FXI TING 2-I TY / ARBORV TAEPLANTINGS / REEXPORT,NY naafi ROBS4T 16YRON-FRE61Dc�iT/GEO APARTMCNI' /, ®4'-0.Or,(II SHOWN) / - 51EVB1 oARROLL-cFO / BUILDING APARTMENT (PEfONaTCV�INb 4 r BUILDING / NEA 200KA CUMMINS j j TA SAP INFORMATION DIESEL GENERATOI2 UPON NEA TIO GALLON / .1 j DN DAY TANK UPON NEA B•THK LONG SLAB / ARBORV TAE(ANT PLANTINGS GRABS / ®4'-O.OC(II SHOW / REMSON DESCRIPION NAME DATE -PRrU—ARY DESGN _- I GM f 9122016 %/ GRABS -- 2 — D SCREEN FL DIINGS DT930.2016 / ] ADDED SCREEN PLANINGS 0 TANKS GM i 1610 2016 f - 4 RENGED AS PER SCHD COMMENTS AGM; 10.31 2016 , , - --- -- - EXISTING,2-I/2 STY. APARTME AREA OF YORK 'BI , AREA OF YORK 'G' ------- - —=- SCALEI r.zo•-o• % GRASS . � - ....__..._... ��. .... .>_ /f '� _ •a��._ � EQUIPMENT LIST - - ` - - __ �...- - -� ---�—�12—.�A�.•,���.yr�2.���.r/f��=1..�.�•��•1_��.I.�1__, - _ -_ ._ .. 669' :` GRAS. G1Y EOUIPMENr x RVFAC IMR MDDEL WHBER PERMIT ACQUISITION AND EXPEDITERS "� �r•``\_ A/6 DA STEEL DAY TANK W CLOSED TOP DIKE TREMONi HAN,FALTUWNG,LLC 1445 GAL W M142 LABEL MICHAEL D UNN, R.A. / NEA 200UMM KA CINS N6 DA STEEL DAY TANK- 19B1 UNION BLVD BAYSHORE, NY 11706 / DIESEL GENERATOR S W CLOSED IOP DIKE TRE)IOM NANFACY R I*.LLL TIO GAL W UL142 LABEL UPON NEA 110 GALLON MEA GREEN GIANT (631) 66$-9619 FAX 969-811$ VY?DAY TANK UPON ARBORVITAE PLANTINGS 4 ALARH PAM! OHNIEC LIPil2 NEA 8•THK CAN,SLAB 0 4'-0'Or-(II SHOW 'COMMERCIAL COMPLIANCE 'PETROLEUM SPEOALISTS •CONNERCIAL SITE PLANNING 'PERMIT EXPEDITING 4 NIGH/LOW LCIEL SWITCH 01011w L^2-5 O �- 4 XMRSTNIAL LEAK SENSOR OMNIEC L-2-5 f jGRASS 11 2'VENICAP OPW 23oo�-oPENVENT FEGONIG LANDING B EMER&EwyvExr MORRISON EROS 244 1500SNFORT, Y ROAD 4 FILL LIMOER MORRISON EROS GREENPORT,NY 11944 ADAPTER a DROP TUBE. l ADAPTER a LOCKING GAP PROJECT DESCRIPRO`I SHEET OESCWPR(X1 / 4 SITE GAUSE SCLLLY GOLDEN&ALLOW 6AU6E .G 71ERATOR F'L7=L TANKS AREAS OF WORK 13,G B D �i/� /. APPROVALSolDaalln y, EXISTING 2-1/2 STY. APARTMENT / i 1000 MAP( BUILDING SCALE. -OI-25 A5 INDIGATEIJ j Dwc a 160803 DRAWN BY C KO BY GFH ON& DATE SHEET v j AREA OF YVORK 'D 9/12/16 ' DWGa A SCALE•1•=20'-O' 3 OF 4 d CROMPI :.Y.`-;•'r.-yk 'iii I L � �� iK*�tAt-4„'f = A PIPE BOPAIM�F_D = YELLOH y \' F'�``:•-i; wo✓ AIAa�M SIAL Bax ��.'•.•• nNb T+EI.I�LL SLNO•MTwMt Ib 4 / j �'."T'°i ��j�'�•T,�-2`>rAe�+:'i•' ,� iui vo Nor .�` #4i1`r.^- .•'z,�r";a2e,`s�:'r,'>�.'1+;':•. LONG IOOn14B,9POa PBI °s!;'�5 »^t•��'a:� .ti.i •. x aOTTr.LL f v.[eE lydv[M Bv¢A[a%9•ATti: 0 1H IPAYS F coma-V .,,� Jr ` '' X�•.' '„yam prt•,. , 61 LOMALTaN MST B[M3>9 ACOA ,e m '�'yy11•��„ ii '^n� _":.•Y•. GonraNlr y4++�._.,,^'?�.;�>"'i�;a^ xy:.;a>`•t, �:•- . 'Y vlEo Nri• na+c.+u agWT lxwx�a exl5nlu bRAveC,EN R //// P.;sxp.!�. ?$•,r,5 ;.Za,7 �..,}. �z';.�,,„rtis=� // a•'pr. � ,1. '•'r'•"'fid .'-,1: v vlexi nn.w AGLO,mwuGe rata M wn / .'S'.�s^✓ T,.L .I'r'r'.�',p�3-K�";,'t"' � .J;,;r::.4„�. Y���„1-;� caEOR cove BTAtIDAIm,aIm nri u w .�' ' // _ :; e*i'r'tr,' 'c�.:y�#.,Czt$,n'.;,�', G�,:r��"'.ay'I.•'� ✓,r s T wrnM.W�Tua ra1R M vouoMNb � � •*';,'�,,- h^�<��•�,'.�` .'i NEN 4'GONG PILLED .� •� ,{r`ry.•:� + '"'` i /' �4'EWL wALIH Ala / / %/ :kti.'r � f _�,RsS�':=-""- 4.'".'.,'.�_ ;.,�,�?.`�•+1 NwxINb LA aura /' BOLLARDS MAX .el.1A you': 1 >p,t;K::.O` :• 4'-O'OL. ✓' ..�T��, +z}'<!i1'4,<"•'�.i3,'r~?'�>�.ah d.�`t.F,f:°e i' - / ' z ! is��i�1 'fid:�•i`:`��� .;;ti11,,..�'`;Rt''"'F.`.:.'�:' '"-:i�'4«: E>�Ce6KbElf A10S BA TAta9NYV4 Bf / / e'«-'„yr �}t'�'•"�,It ;a EXISTMG 450 KW vL.'_L "r:.P*i"!��VI�•��� �x�; .>!'i 4oXP roP au a i�iaxsbw uLlN t/.BN'er.B®� •�14' / ,�// f VIO,FL C-EWERATOR BALLON DAY TANK / EXISTIG 3 5TY. BOLLARD DETAIL FRAME_NID6 w J ZONING DATA GARAGE UNDER j- / NOT TO SCALE ASPHALT / CONTACT INFO / PEf IG LAt91N6 AT SaV111aLa,INC / ROOF f bRfffd'OT''M'<aa OVER / ROBERT 15YRgR-FRE564T!1 LEO L01G I1LED e011Ana ENTRY / � E%ISTING / ExISTING 151Y. / STEVEN G/,RRaLL-civ N Iex aeTAa V TRANSFORI•IER GOI`9MUNITY // (bep MTslroa x]]4 CENTER P[C0f110.A1 mINBORb y..0. v ® • ®M / EXISTINGR. PO DIESEL i TAX MAP INFORMATION GEI�RA70R PO _ J a y E EXISTING.TO GALLON 000-59 -S / DAY TAMC TO REMAIN ATb9PM -AlT eENeRwrolaOw 'r GONG r ° ---- i------ ------ ------ •wutrloN aveR GRASS REVISIM DESCRIPTION NAME DATE 1 PRMWNARY DELGV GM Y 9121016 J P\ 1 CONG ASPHALT 2 CCNSTRUCTIDN ODCW[NTS Y M 910.1016 • ! ! oI rcl Twrac 51IILY Ld[ �jKMw LnL `-, ]MaI 3 G_ _ ADDED SCREEN PLANTINGS a TMXS— GM '< 10.10 2016 V�� ! I ]9LM1Y Ert[ 11 f^ LML AWIM —.— — n 0 REVISED AS PCR SCHD COMMENTS GFH 10.311016 s ! ! ]x � r roxlnEou ewaE ..r.•• r ------- ----- - -- vpN LM•M A.T. ;;•; ----- -- ---- _ - ( aa�ELAS J/ /' / --- --- - --------- -----•--- --- 1,445 GALLON D1=5EL DAY TANK PLAN / %/' —— — -- --- --` AREA OF WORK 'A' PERMIT ACQUISITION AND EXPEDITERS MICHAEL DUNN, R.A. TLIm1v IBJEL wOBe ENAu 1961 UNION BLVD BAYSHORE, NY 11706 (631) 665-9619 FAX 969-0115 1 I uPirnr a M v.Rc , I ; 1 ]91nn++xY Noxxnb vENr -ENVIRONMENTAL COMPLIANCE -PETROLEUM SPEdAL15T5 w SOALY wubnE VENT G,v i i I +b•ATT fwlw hw-Aeoae 'CONMERGAL SITE PLANNING 'PERMIT EXPEDITING a50 cN pE6Ti bF RAT04 bRABE Miw I ' Nb Bf ODn4VD EVILR e0@RATOµINc I 29 PR=YORKMb VDa , ECCOWwxY ' MODEi-.Mo areJ w vpB I +b•Ar l�(A.m 11-0•ABOV2 �lP/t�i i.UAt b„�. ,M Nava YeN,Eb•ATT PEGONIG LANDING i I LIIV3 wbu = v-Ecu.EY B 1500 REGKNOGK ROAD I % L[vEL u.r,RN ' I I br1u.lAx,'e.aw nr w1r 1-1 o— GREENPORT,NY 11944 T , IOUED�W] I f��EnLL fbrtl Y✓EM PRQ CT DESCRiPTW SHEET OESCRIPTXW AR1'wra --_ FIEal�.Eu ____ ___ Y rAtae _ .___ t+L !✓ �___-J P a�'+ IIusIe1.Bvx seAum m GB'ERATOR FilEl.TANKS AREA OF iNORK A �'- ----------- -------------------- A P P R O V A L 8 Y 3 EA��"w'.,Trs.,1°�"� � rRb1•.RY TEne aAaBe ; ''�,""" I �,�R4°"mu��&e A,a I �EMIP;�ixv pY° 1RE ALL ST I F 1�y T��1EaN i I ��rtt rz[t i bELODARY TANG n , ootAli 1IaEL rm en9�a a ka•°i ccP} ° NI ]rolauEox ew0>+ao06 i I N7 fAK ' dT UK i PLLL LIMnOt W zTloP r12G , , TAX NAP/ W.1/6 I Ao.VrHi,1.oG%aa LAI I' BDm1' W. 3m 0Y.— 1 ————— —— —..-el Txwx IL SUB W bxb mn0 NM+ e � 310 ————————————————— •b MxE•h'OG.[)t fa00o 141 ' aATm Ex,emlub u• AS INDICATED t ( DNAP rwt].'c"ELAB TAu¢]sLwB160803 DRANK BY G1X'D BY .ou.rn+b alo�avrw'.vl GFH GWG DATE. snECT 1,445 GALLON DIE5EL DAY TANK ELEVATION'(MPG BY TRAMONT MPG, LLC) DAY TANK SIDE ELEVATION Hil�n6 X1 P2 OF 4 SCALE,V3•°1-O• SCAIF,Irz"=I_O• T '1 -�•-i�i...-�''•.;r3�d�E?i` fi{., :•,,fit!•.„'j-;.6rinN..„ BLLTLY wOTLe r--z, fT�Y:}Yy'tt't•.<"�"� B.- i�i�}tFRY4h,•�1'i�LL Y_".t;�<}� YI�55tYOlIDwttY nTlKw6 J�. +2'.i.R.R :« �r:•f:+r.�`: .:,:4•.".i£f",i'•�.E?;” c w-s NNIaH 6Eitu•-o uveL smmcx w]• PH ,QNB - ZONING: DATA T•I°Pm+eall seas r]w CONTACT INFO f- 6 � � , secarmwar tsxReeroY vt]+r PEGONIG LANDINB AT SGTtRiaLm,INA i r——————— ———————,— r——— ' c L-]-s wtERSTrtM,L LFl•K IBOo aNPslaorx Im i LJ snaow w]•BNNs IeanNlo yAls.ut>Et.s. aae�w i s crani�ESIOEIR.cea 9}9}9}9}9}9} % SII\\ I ! •_ �� Pa�iY'Ou�r v�eur siw'riw A-»eN'�ne'sia�'Ars.,s�pJea�smJ�M�ThuLBOe revlN cArwau-ceo F I /// i dtACI:nS I , \! vETwLL A Lw0[L wglDe TIC GVILL BCA BTATw6 PECONKLhN01NbORG / A-1-0 W9T Be L• AIID h t / i r ( Lea]In6,+ mesa • now eAN ttOULr m A snLL or TAX MAP INFORMATION , ' I Level AURN i000-3B-I-a ' _ L---- —L-------'-- SP — — •aVEavLCM m/0. MFlLL PCRi 5W11 BPARA Wto0.WCl LCR L_ _ __ mesa nn w,wcoNmwce wa M AFl eucTmcAl o-1. -•1 K DAA. °•x.e K rwreL A°+»�wrs svAce w taloa rens sTArroAxv.ev�eL H.TE eA BTUBHA'wIUJ. Q -- LY LOE==� t¢TNM L98 W 6..LL ]•JCLLN'Bli¢OAW---- !C%YnLIC TC TCLLCH MXADON ` -Ti--•- I TAN[TCP= .LLL WRle 9m6 ANK wNN TNe FouanwB T TAI F 5LAB yfM TA1M N11ECf. ]•­90LD9 CCMINIg 91f5eL fttl /M1L LBaIeRWDPav TUBO G.rAGx Gr TAN[ REVSICN DESCRIPTON NAME DATE .]APr@f.LCCKwG al.v jptCpb LAVAGtt Or TANK 1 PREUUJNARY DESIGN CiH 9.12 20t6 2 CONSTRUCTION ODCIMENTS GM 9202016 MOSt J ADDED SCREEN PLANTNOS 0 TANKS ,GfH 10.10.2016 1 d REV '110 GALLON DIESEL DAY TANK PLAN wB aABA�e � � taNtM°•cMws uC Ate`Rales aro ISED PER AS SCHD COMMENTS GfH 0.312016 ANCB W I.Ue]LABCL9 SCALE.112'=1'ro' , —--_________— M�`iNxTo Level wase slwl .-��'y�If :.� ---•^.r.Jr s_—.•-..—�., I _.�.- -.•.—tet �....... G hT�5.O/Mai•�AlA'W - .. -.-- .+.. . �. ....... �aHSW-t A {+�.�.^ ..• .. _ .. -_ _.... ....-. . -, .. - ..- . _.. .... . GCItEAwipR... .--aAVACrtY CP M TANG , i aPND.M.RY.>GRAwOveerw ' ��Lsz�Z451RSa9:kS lsa'lLeJpJ� dS/sz5 uol"I-1p.:+e N'Brs: ATT I PERMT ACQUISITION AND EXPEDITERS A ,TwTO�•ATT a t�sao»�smotmwnr �M MICHAEL DUNN, R.A. awa I,A.Y PRAK�KNT I 1981 UNION BLVD HAYSHORE• NY 11706 I tL,sP v eoA!lALm To - ,t+ol.ItlsoN Boos r].. (631) 665-9619 FAX 969-0115 I Tc SefamANr lNeASewrY VIXr -ENVIRONMENTAL COMPLIANCE -PETROLEUM SPECIALISTS AMC]•eaLL.LY 511!R OAYJ! 9 eal OF¢L/FNLL B__ -COMMERCIAL SITE PLANNING 'PERMIT EXPEDITING ALAmt •ae ".' --- ---------------------------I _ PEGONIG LANDING 1500 BREGKNOGK ROAD i I ]•NOrs11%OM B"O3 r 'I DIOL I GREENFORT,NY 11-144D roG09 LL Lvn!R W DOLL �'I LocK w.°�A�rs I PZB B�eceEwY veer 11 '710 BIAIAI dqUDUE WALL Sl[0. I I 710 OALLDN Q wMA TA c , PRO QCT OESCRIPOQV SHEET DESCRIP ON 00UB E WALL STM j I 99 sco mwa Tw x I ggLpµ I GENERATOR WEL TANKS DAY TANK B,G 8 D I �r �; I� I i L'----J I APPROVALS .cress ur.w w. J -11 a2°Y{�°"e0 yll•.pt.,,o L— —J B•TNT.t PL BLAB w d�1 �w 1 � ---------~---- ----- BYb IOro IC•N1 HDOO �' ALL TANG Ea6E5 �TANc 5LN) °°R De a wl"la bu•copy no SGoR=TANG I TA!NPP/ 1000-55-0I-25 TAiK SUB SCALE , - AS INDICATED , Dw g 160803 •TIO GALLON DIE5EL DAY TANK ELEVATION(MFG BY TRAMONT MFG,LLC) DAY TANK 51DE ELEVATION DRAxNGFH GNl6 SCALE.I/1'•I•-O' SLPLE.I/2`a I-O' GATE SHEET 4/1 Ab X 1 D �40F 4 Power Generation Specification sheet Diesel , Generator set QSB7 series engine 100-200 kW 60 Hz Description Cummins Power Generation commercial Control system -The PowerCommand®1.1 generator sets are fully integrated power electronic control is standard equipment and generation systems providing optimum provides total genset system integration including performance, reliability and versatility for automatic remote starting/stopping, precise stationary standby and prime power frequency and voltage regulation,alarm and status applications. message display, output metering, auto-shutdown at fault detection and NFPA 110 Level 1 Features compliance. The optional PowerCommand 2.2 Cummins®heavy-duty engine -Rugged 4- control is UL 508 Listed and provides AmpSentry'" cycle, industrial diesel delivers reliable power, protection. low emissions and fast response to load Cooling system -Standard integral set-mounted changes. radiator system,designed and tested for rated Alternator-Several alternator sizes offer ambient temperatures,simplifies facility design selectable motor starting capability with low requirements for rejected heat. reactance 2/3 pitch windings, low•waveform Enclosures-Optional weather protective and ' distortion witir non-linear loads and fault=-- sound attenuated enclosures are available. w= clearing short-circuit capability. . _ NEPA-The genset accepts full rated load in a single step in accordance with NFPA 110 for Level 1 systems. Warranty and service-Backed by a comprehensive warranty and worldwide distributor network. Standby rating Prime rating Continuous rating Data sheets 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz Model kW(kVA) kW(kVA) kW(kVA) kW(kVA) kW(kVA) kW(kVA) 60 Hz 50 Hz DSGAA 100 125 90 113 D-3349 DSGAB 125 156 113 141 D-3350 DSGAC 150 188 135 169 D-3351 { DSGAD175 219 -"s' ''` 16 200 D-351 DSGAE 200 250 D-3517 a'mooW no bb V t r © cummmspower.com 02015 Cummins Power Generation Inc S-1544n(3/15) , A . Generator set specifications Governor regulation class ISO 8528 Part 1 Class G3 Voltage regulation,no load to full load t 1 Random voltage variation t 0 5% Frequency regulation Isochronous Random frequency variation t 0.25% Radio frequency emissions compliance I Meets requirements of most industrial and commercial applications Engine specifications Bore 107 mm(4.21 in) Stroke 124.0 mm(4 88 in) Displacement 6 69 L(408 in 3) Configuration Cast iron,in-line,6 cylinder Battery capacity 1100 amps minimum at ambient temperature of-18°C to 0°C 0°F to 32° Battery charging alternator 100 amps Starting voltage 12 volt,negative ground Fuel system Direct injection:number 2 diesel fuel,fuel filter,automatic electric fuel shutoff Fuel filter Single element,10 micron filtration,spin-on fuel filter with water separator Air cleaner type Dry replaceable element Lube oil filter type(s) Spin-on,full flow Standard cooling system High ambient radiator Alternat®r specificati® s Design Brushless,4 pole,drip proof,revolving field Stator 2/3 pitch Rotor Single bearing,flexible discs Insulation system Class H Standard temperature rise 150°C standby at 40°C ambient Exciter type Torque match(shunt)standard,PMG optional Phase rotation A(U),B(V),C(W) Alternator cooling Direct drive centrifugal blower fan AC waveform total harmonic distortion <5%no load to full linear load,<3%for any single harmonic Telephone influence factor(TIF) <50 per NEMA MG1-22.43 Telephone harmonic factor(THF) <3 Available voltages 60 Hz Three phase line-neutral/line-line - 1 60 Hz Single phase line-neutral/line-line • 110/190 • 115/230 Delta • 127/220 •240/416 110/220 •115/230 120/240 • 110/220 • 120/208 • 139/240 •255/440 9 115/200 9 120/240 Delta • 220/380 •277/480 • 230/400 •347/600 not available with DSGAD or DSGAE Note.Consult factory for other voltages Generator set options and accessories Engine Alternator Exhaust system ❑ Remote annunciator panel ❑ 120 V 150 W lube oil heater lif 105°C rise ❑ Heavy duty exhaust elbow ❑ Spring isolators W( 120F240 V 1500 W coolant ❑ 125°C rise ❑ Slip on exhaust connection ❑ 2 year prime power warranty heater ❑ 120 V 100 W anti- Generator set N( 2 year standby power Fuel System condensation heater ❑ Battery warranty ❑ 24 hour sub-base tank it PMG excitation W Battery charger ❑ 5 year basic power warranty (dual wall) ❑ Single phase it Enclosure:aluminum,*Wei- ... sound attenuated W Main line circuit breaker Note:Some options may not be available on all models-consult factory for availability. car EWA® cumminspower com 02015 Cummins Power Generation Inc I S-1544n(3/15) Control system PowerCommand 1.1 Alternator data • Line-to-line and line-to-neutral AC volts •3-phase AC current • Frequency • •Total kVA ' Engine data • DC voltage • Lube oil pressure • Coolant temperature • Engine speed PowerCommand control is an integrated generator Other data set control system providing voltage regulation, engine . Genset model data protection,operator interface and isochronous .Start attempts,starts, running hours governing(optional). Major features include: . Fault history • Battery monitoring and testing features and smart • RS485 Modbus®interface starting control system. • Data logging and fault simulation(requires InPower •Standard PCCNet interface to devices such as service tool) remote annunciator for NFPA 110 applications. Digital governing (optional) • Control boards potted for environmental protection. • Control suitable for operation in ambient • Integrated digital electronic isochronous governor temperatures from-40°C to+70°C(-40 °F to •Temperature dynamic governing +158 °F)and altitudes to 5000 meters(13,000 feet). Digital voltage regulation • Prototype tested; UL,CSA,and CE compliant. e Integrated digital electronic voltage regulator • InPower PC-based service tool available for a 2-phase line-to-line sensing detailed diagnostics. . Configurable torque matching Operator/display panel Control functions • Manual off switch •Alpha-numeric display with pushbutton access for •Time delay start and cooldown viewing engine and alternator data and providing • Cycle cranking setup, controls and adjustments(English or • PCCNet interface international symbols) • (2)Configurable inputs • • LED lamps indicating genset running, not in auto, R Configurable outputs • Remote emergency stop common warning,common shutdown, manual run • Glow plug control (some models) mode and remote start •Suitable for operation in ambient temperatures from Options -20°C to+70°C ❑ Auxiliary output relays(2) • Bargraph display(optional) ❑ 120/240 V, 100 W anti-condensation heater AC protection ❑ Remote annunciator with(3)configurable inputs and • Over current warning and shutdown (4)configurable outputs • Over and under voltage shutdown _�.•r _WF PM G_alternator_excitation _ • Over and under frequency shutdown _ 11 PowerCommand Watch web server for remote • Over excitation (loss of sensing)fault monitoring and alarm notification (loose) • Field overload ❑ Auxiliary, configurable signal inputs(8)and configurable relay outputs(8) Engine protection d Digital governing • Overspeed shutdown ❑AC output analog meters(bargraph) • Low oil pressure warning and shutdown - Color-coded graphical display of: • High coolant temperature warning and shutdown - 3-phase AC voltage • Low coolant level warning or shutdown - 3-phase current • Low coolant temperature warning - Frequency • High, low and weak battery voltage warning - Wa • Fail to start(overcrank)shutdown ❑ Remote operator panel • Fail to crank shutdown • Redundant start disconnect 11PowerCommand 2.2 control with AmpSentry • Cranking lockout protection • Sensor failure indication • Low fuel level warning or shutdown For further detail see document S-1531. • Fuel-in-rupture-basin warning or shutdown cumminspower com 02015 Cummins Power Generation Inc 15-1544n(3/15) Ratings definitions Emergency standby power(ESP): Applicable for supplying power to varying electrical - -- - load for the duration of power interruption of a reliable utility source. Emergency Standby Power(ESP)is in accordance with ISO 8528. Fuel Stop power in 13 accordance with ISO 3046,AS 2789, DIN 6271 and BS 5514. Limited-time running power(LTP): Applicable for supplying power to a constant electrical load for limited hours. Limited Time Running Power Dim'c^ (LTP)is in accordance with ISO 8528. Prime power(PRP): Applicable for supplying power to varying electrical load for unlimited hours. Prime Power(PRP)is in accordance with ISO 8528.Ten percent overload Dim"A"_ capability is available in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514. Base load (Continuous) power(COP): This outline drawing is for reference only See respective model Applicable for supplying power continuously to a data sheet for specific model outline drawing number. constant electrical load for unlimited hours. Continuous Do not use for installation design Power(COP) in accordance with ISO 8528, ISO 3046, AS 2789, DIN 6271 and BS 5514. Dim"A" Dim"B" Dim'1C" Set Weight* Set Weight* Model mm(in.) mm(in.) mm(in.) drip kg(lbs) wet kg(lbs) DSGAA 2656(104 6) 1100(43.3) 1549(61) 1180(2602) DSGAB 2656(104 6) 1100(43 3) 1549(61) 1225(2700) DSGAC 2656(104 6) 1100(43.3) 1549(61) 1263(2784) DSGAD 2656(104.6) 1100(43.3) 1549(61) 11361 (3000) DSGAE 12656(104 6) J 1100(43 3) 1549(61) 1361 (3000) *Note:Weights represent a set with standard features See outline drawings for weights of other configurations Codes and standards Codes or standards compliance may not be available with all model configurations-consult factory for availability. This generator set is designed in facilities The generator set is available listed to certified to ISO 9001 and manufactured 41 UL2200 UL 2200. facilities certified to ISO 9001 or 180 9002 The Prototype Test Support(PTS)program Engine certified to Stationary Emergency U.S. verifies the performance integrity of the generaror set design Cummins Power Generation EPA New Source Performance Standards, products beans the PTS symbol meet the U.S. EPA 40 CFR 60 subpart IIII Tier 3 exhaust emission P 9 Y levels. U.S.applications must be applied per prototype test requirements of NFPA 110 for this EPA regulation. Level 1 systems. The generator set package is available certified International for seismic application in accordance with the C22 2 No 100 and CSA C22.2 No.14 CSA All low voltage models are certified . CSA Building following International Building Code: Code IBC2000,IBC2003 IBC2006,IBC2009 and IBC2012 Warning:Back feed to a utility system can cause electrocution and/or property damage.Do not connect to any building's electrical system except through an approved device or after building main switch is open North America 1400 73rd Avenue N.E. Minneapolis,MN 55432 USA Phone 763 574 5000 Fax 763 574 5298 PoWer er Generation 02015 Cummins Power Generation Inc All rights reserved Cummins Power Generation and Cummins are registered trademarks of Cummins Inc PowerCommand,AmpSentry,InPower and"Our energy working for you"are trademarks of Cummins Power Generation Other company,product,or service names may be trademarks or service marks of others Specifications are subject to change without notice cumminspower com S-1 544n(3/15) Model: DSGAE Frequency: 60 Fuel type: Diesel KW rating: 200 standby 180 prime Emissions level: EPA NSPS Stationary Emergency Tier 3 a�•, B B — �� ,3 ? ,f :biz'`�� a «� 4 £ s s..j'a'i a'x.-�$`".�:' ,«.� r.s�f s •{ � '�, Exhaust emission data sheet: EDS-1124 Exhaust emission compliance sheet: EPA-1173 Sound performance data sheet: MSP-1102 Cooling performance data sheet: MCP-210 Prototype test summary data sheet: PTS-286 Standard set-mounted radiator cooling outline: A03SC611 Optional set-mounted radiator cooling outline: 1 Optional heat exchanger cooling outline: d Optional remote radiator cooling outline: Standby Prime Continuous Fuel Consumption kW(kVA) kW(kVA) kW(kVA) F Ratings 200(250) 180(225) Load 1/4 1/2 3/4 Full 1/4 1/2 3/4 Full Full US gph 5.20 8.67 11.63 1479 4.79 8.16 10.81 13.36 _ L/hr 19.7 32.8 44.0 56.0 18.1 3 9 40.9 50 6 Engine Standby Prime rating rating Continuous rating Engine manufacturer Cummins Engine model QSB7-G5 NR3 Configuration Cast Iron,In-line,6 cylinder i Aspiration Turbocharged and air-to-air aftercooled _r Gross engine power output,kWm(bhp) 242 324 208 279 'BMEP at set rated-load,Oar(psi) 2255327 295 ( ) 2033 C ) - Bore,mm(In) - 107(4.21) Stroke,mm(in) 124(4.88) Rated speed,rpm 1800 Piston speed,m/s(ft/min) 7.4(1464) i Compression ratio 17.2:1 ? Lube oil capacity,L(qt) 17.5 18.5 j Overspeed limit,rpm 2100 Regenerative power,kW 19 " Fuel flow Maximum fuel flow,Uhr(US gph) 106(28) Maximum fuel flow with C174,Uhr(US gph Maximum fuel Inlet restriction with clean filter,mm Hg in Hg) 127(5) Maximum return restriction,mm Hg(In Hg) 152(6) 02011 Cummins Power Generation Inc All rights reserved Cummins Power Generation and Cummins are registered trademarks of Cummins Inc"Our energy working for you"is a trademark of Cummins Power Generation Specifications are subject to change without notice, D-3517(8/11) Standby Prime Continuous rating Air rating rating Combustion air,m'/mm scfm) 15.8(557) 15.3(539) ' Maximum air cleaner restriction with clean filter,kPa(in H O) 3.7(15) Alternator cooling air,m3/min(cfm) 41 3(1460) 9i Exhaust Exhaust flow at set rated load,m3/min(cfm) 40.5(1428) 37 7(1332) Exhaust temperature,°C(°F) 510(949) 484(903) Maximum back pressure,kPa(in H O) 10(40) 10(40) Standard set-mounted radiator cooling Ambient design,°C(°F) 50(122) i Fan load,kW.(HP) 9.7(13.0) Coolant capacity with radiator),L(US Gal) 23(6.1) 23(6.1) Cooling system air flow,m3/min(scfm) 351 (12400) Total heat rejection,MJ/mm(Btu/min) 9.90(9376) 8 95(8481) Maximum cooling air flow static restriction,kPa(in H O) 0.12(0.5) Optional set-mounted radiator cooling Ambient design, °C ° I Fan load,kW.(HP) _ F Coolant capacity(with radiator),L(US Gal.) Cooling system air flow,m3/min(scfm) Total heat rejection,MJ/mjn(Btu/min) Maximum cooling air flow static restriction,kPa(in H,0) Optional heat exchanger cooling Sac coolant capacity,L(US Gal) Heat rejected,jacket water circuit,MJ/min(Btu/min) Heat rejected,aftercooler circuit,MJ/min(Btu/min) Heat rejected,fuel circuit,MJ/min(Btu/min) Total heat radiated to room,MJ/mm(Btu/min) Maximum raw water pressure,jacket water circuit,kPa(psi) A Maximum raw water pressure,aftercooler circuit,kPa(psi) l Maximum raw water pressure,fuel circuit,kPa(psi) I Maximum raw water flow,jacket water circuit,Umin(US Gal/min) Maximum raw water flow,aftercooler circuit,Umin(US Gal/min) Maximum raw water flow,fuel circuit,Umin(US Gal/min) _ Minimum raw water flow at'27°C-(80"F)inlet temp,jacket water circuit, Umin US Gal/min Minimum raw water flow at 27°C(80°F)inlet temp,aftercooler circuit, C Umin US Gal/min Minimum raw water flow at 27°C(80°F)inlet temp,fuel circuit, Umin ` US Gal/min Raw water delta P at min flow,jacket water circuit,kPa(psi) Raw water delta P at min flow,dftercooler circuit,kPa(psi) j Raw water delta P at min flow,fuel circuit,kPa(psi) f Maximum jacket water outlet temp, °C(°F) Maximum aftercooler inlet temp, °C(°F) ! Maximum aftercooler inlet temp at 25°C(77°F)ambient, °C(°F) Our energy working for you:M www cumminspower com 02011 Cummins Power Generation Inc All rights reserved Cummins Power Generation and Cummins are registered trademarks of Cummins AERIQM Inc "Our energy working for you"is a trademark of Cummins Power Generation Specifications are subject to change without notice Generation D-3517(8/11) l r Optional remote radiator cooling' Standby Prime Continuous rating rating rating Set coolant capacity,L(US gal) f Max flow rate at max friction head,jacket water circuit,Umin(US gal/min) ) Max flow rate at max friction head,aftercooler circuit,Umin(US gal/min) j Heat rejected,jacket water circuit,MJ/min(Btu/min) Heat rejected,aftercooler circuit,MJ/min(Btu/min) 1 Heat rejected,fuel circuit,MJ/min(Btu/min) } Total heat radiated to room,MJ/min(Btu/min) Maximum friction head,jacket water circuit,kPa(psi) Maximum friction head,aftercooler circuit,kPa(psi) { Maximum static head,jacket water circuit,m(ft) j Maximum static head,aftercooler circuit,m(ft) f Maximum jacket water outlet temp,°C(°F) ? Maximum aftercooler inlet temp at 25°C(77°F)ambient,°C(°F) 7 [ Maximum aftercooler inlet temp,°C(°F) Maximum fuel flow,Uhr(US gph) Maximum fuel return line restriction,kPa(in Hg) i Welghts2 Unit dry weight kgs lbs.) i Unit wet weight kgs(lbs.) 1361 (3000) Notes: 'For non-standard remote installations contact your local Cummins Power Generation representative. 2 Weights represent a set with standard features See outline drawing for weights of other configurations. Derating tactors Engine power available up to 1707 m(5600 ft)at ambient temperature up to 40°C(104°F)and 732 m Standby (2400 ft)at 50°C(122°F). Consult your Cummins Power Generation distributor for temperature and ambient requirements outside these parameters. Engine power available up to 1707 m(5600 ft)at ambient temperature up to 40°C(104°F)and 732 m Prime (2400 ft)at 50°C (122°F). Consult your Cummins Power Generation distributor for temperature and _ ambient requirements outside these parameters. Continuous Ratings deiniti®r®s Emergency standby power Limited-time running power Prime power(PRP): Base load(continuous) (ESP): (LTP): power(COP): Applicable for supplying power to Applicable for supplying power Applicable for supplying power Applicable for supplying power varying electrical load for the to a constant electrical load for to varying electrical load for continuously to a constant duration of power interruption of a limited hours. Limited Time unlimited hours.Prime Power electrical load for unlimited reliable utility source Emergency Running Power(LTP)is in (PRP)is in accordance with ISO hours.Continuous Power(COP) Standby Power(ESP)is in accordance with ISO 8528. 8528.Ten percent overload is in accordance with ISO 8528, accordance with ISO 8528.Fuel capability is available in ISO 3046,AS 2789,DIN 6271 Stop power in accordance with accordance with ISO 3046, and BS 5514. ISO 3046,AS 2789,DIN 6271 and AS 2789,DIN 6271 and BS 5514. BS 5514. Our energy working for you.TM www,cu mm inspower.com 02011 Cummins Power Generation Inc All rights reserved Cummins Power Generation and Cummins are registered trademarks of Cumminsower Inc "Our energy working for you"is a trademark of Cummins Power Generation Specifications are subject to change without notice eratio D-3517(8/11) d ' Alternator data Three Phase Table' 105°C 105°C 1105-C 125°C 125°C 125'C 150°C 150°C 150°C Feature Code 8418 8415 B304 B417 B414 B303 B416 8413 B419 Alternator Data Sheet 212 212 212 212 212 212 211 211 211 Number Voltage Ranges 110/190 120/208 347/600 110/190 120/208 347/600 110/190 120/208 347/600 Thru Thru Thru Thru Thru Thru 120/208 139/240 120/208 139/240 120/208 139/240 220/380 240/416 220/380 240/416 220/380 240/416 Thru Thru Thru Thru Thru Thru 240/416 277/480 240/416 277/480 240/416 277/480 Surge kW 1212 212 215 212 212 215 212 205 214 Motor Starting kVA(at Shunt 770 770 770 770 770 770 672 672 672 90%sustained voltage) PMG 1920 920 1920 920 1920 920 1791 791 1791 Full Load Current - 120/208 127/220 139/240 220/380 240/416 254/440 277/480 347/600 Amps at Standby 694 656 602 380 347 328 301 241 Rating Single phase power can be taken from a three phase generator set at up to 2/3 set rated 3-phase kW at 1.0 power factor. Formulas for calculating full load currents: Three phase output Single phase output kW x 1000 kW x Single Phase Factor x 1000 Voltage x 1.73 x 0.8 Voltage Cummins Power Generation 1400 73"Avenue N E. Minneapolis,MN 55432 USA Telephone:763 574 5000 Fax:763 574 5298 Warning: Back feed to a utility system can cause electrocution and/or property damage. Do not connect to any building's electrical system except through an approved device or after budding main switch is open. Our energy working for you:m www cumminspower com ©2011 Cummins Power Generation Inc All rights reserved Cummins Power Generation and Cummins are registered trademarks of Cummins WO Power Inc "Our energy working for you"is a trademark of Cummins Power Generation Specifications are subject to change without notice Generation D-3517(8/11) ¢