Loading...
HomeMy WebLinkAbout41848-Z t ��®�psUFF�t'��dGy Town of Southold 11/2/2017 o - P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39324 Date: 11/2/2017 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 725 Peconic Ln, Peconic SCTM#: 473889 Sec/Block/Lot: 75.-5-3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application'for Building Permit heretofore filed in this office dated 7/26/2017 pursuant to which Building Permit No. 41848 dated 7/28/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Sakowicz, Stella of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 41848 10-11-2017 PLUMBERS CERTIFICATION DATED Authorized Signature �o�guFFnc,r�o TOWN OF SOUTHOLD BUILDING DEPARTMENT z TOWN CLERK'S OFFICE o • g SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41848 Date: 7/28/2017 Permission is hereby granted to: Sakowicz, Stella PO BOX 173 Peconic, NY 11958 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 725 Peconic Ln, Peconic SCTM # 473889 Sec/Block/Lot# 75.-5-3 Pursuant to application dated 7/26/2017 and approved by the Building Inspector. To expire on 1/27/2019. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 ffj _eff�_' nspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00;Alt6fations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00;Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 ' 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 Date. ,4 New Construction: Old or Pre-existing Building: (check one) c� Location of Property: 777- 57 _ ec 0Aj C. (0,AR e cc ic— House No. Street Hamlet Owner or Owners of Property: _-54e t lc� S a k O W:C Z Suffolk County Tax Map No 1000, Section 75 Block (5- Lot 13 Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ r A cant Signature %JT so Town Hall Annex Telephone(631)765-1802 54375 Main Road y Fax(631)765-9502 P.O.Box 1179 • �Q roger.richert(a�-town.southold.ny.us Southold,NY 11971-0959 Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Sakowicz Address: 725 Peconic Lane city:Peconic st: New York zip: 11958 Building Permit* 41848 Section: 75 Block: 5 Lot: 3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Momentum Solar License No: 37608-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency FixtureTime Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: 14.28 KW Roof Mounted Photovoltaic System to Include 51--250 W Panels with 51- Micro Inverters, Combiner Box, A/C Disconnect. Notes: Inspector Signature: Date: October 11, 2017 0-Cert Electrical Compliance Form.xls momentum SOLAR D [EC[E0V[E DD NOV 9 2017 November 2, 2017 BUILDING DETT. TOWN OF SOITIVNID Town of Southold Building Department PO Box 1179 Southold, NY 11971 Subject: Engineer Statement for Solar Roof Installation Residence: Stella Sakowicz - 725 Peconic Lane, Peconic, NY 11958 Permit No.+U" JqI8 y Post Installation Inspection Date: 11/1/17 The roof mounted photovoltaic system at the above referenced residence has been observed to be installed properly in accordance with the approved plans and is certified by Daniel W Dunzik Engineering Services, P.C. to be in compliance with the minimum requirements of the Town, the 2015-International Residential Code and the 2016-New York State Uniform Code Supplement and the Provisions of ASCE 7-10. e6rRED ARC W.DL/Al. / Si i� i Li OF N Engineer' 45 Fairchild Ave D:631.536.4100 Suite B F:732.902.6223 Plainview,NY 11803 W:momentumsolar.com FIELD INSPECTION REPORT I DATE COMMENTS . b FOUNDATION (1ST) 4G ------------------------------------ d C � FOUNDATION (2ND) tt� z � o ROUGH FRAMING& y �\ PLUMBING s 9 INSULATION PER N.Y. �y STATE ENERGY CODE FINAL ADDITIONAL COMMENTS iFe�lU D m r— S d b y TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631)765-9502 Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application / 26Flood Permit Examined ,20 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved ;20 Mail to: Disapproved a/c PP r Phone: Expiration ,20 D mem nim Bu ing Ins ctor LICATION FOR BUILDING PERMIT J U L 2 6 2017 Date �'y� �`� , 20� INSTRUCTIONS IG a. �,� tp � I ompletely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plan , cc r �� p o e.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection-throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations, for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. w (Signature of applicant or name,if a corporation) t4s .." Seso4 Bi /J� ]it (Mailing address of applicant) State whether applicant is owner, lessee, ZeAfle- nt, architect,,co, general contractor, electrician,plumber or builder 1 `e,4.-,C io e Name of owner of premises :54e l l cA 5c,k o w.'c Z (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer 'co r C h r ak-4-s,&,, Ca.n LA c�n (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. 3-)Cog~ �l�► Other Trade's License No. -- 1. Location of land on whichroposed work will be done: I'Z l; �,econ"C L QVI e PecoV%I r- House Number Street Hamlet - County Tax Map No. 1000 Section 7 s Block �'�' Lot Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost-0r 17.'x. ,00 Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of�Stories-h ;-.r; ��F• I so;� 7 nI • 8. Dimensions of entire new construction: Front Rear 1 c = Height Number of Stories � � 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO-�— 13. Will lot be re-graded?YES NO—A-Will excess fill be removed from premises?YES NO_V_ -7Z S IPecb-'r- Cane 14.Names of Owner of premisesSfel6, Se ko vicZ Address .41 V I IC49V Phone No. G3i -765- -2,572-7 Name of Architect „; Address ger, "' 1� Phone No 63i- 3�-yr�� Name of ContractorC�t6., " r������Address c!s Fu�.A.I1Ae5��hone No._��1����ioo PlO11i•°�;owr A)V 11803 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO_)� * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO),— * IF YES, PROVIDE A COPY. STATE OF NEW YORK) r COUNTY OF&ff,, SS: being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the��./"/�/- (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to�efore me this day of u 20 11 A ` THOMAS R. MANSFIELD IC,STATE OFJqrvv TUNK Signature of Applicant otary Public No.01 MA6357321 QUALIFIED IN SUFFOLK COUNTY IM' Y COMMISSION EXPIRES APRIL 17,2021 Town Hall Annex Tclephone(6311))765-1802 54375 Main Road ,ax(681)7U145� P.O.Sox 1179 G 94 r949L dchert(dio 4n.s0 O nV us Southold,NY 11971-0959 '� �' ��il l ss BUILDING DEPARTN ENT TOWN OF SOUTHOLD ,APPLICATION FQR ELECTRICAL INSPECTION • r REQUESTED BY: rte;. ;_n __ , , Date: Gin 1 Company Name: aY" Name: License No.: 65 -16 - 14 Address: .� �kr c�4t,�� i h V� ! t U Phone Na.: y C�3.!. ..S 3(n 100 JOBSITE INFORMATION: (*Indicates required information) *Name: 11�R V-d Lm i G`'t 'Address: 4t LOU, .�sL _ 2 C9�n t G 9 S - *Cross Street: a *Phone No.: Permit No.: - Ll i Tax-Map District: 1000 Section: Block: Lot: , *BRIEF DESCRIPTION OF WORK(Please Print Clearly) Sd�Qr lease Circle All That ply) *Is job ready for inspection: YES NO Rough In Final *Do.you need a Temp Certificate: YE / NO Temp Information(if.needed) *Service Size: 1 Phase Whase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead � Additional Information: PAYMENT DUE WITH APPLICATION ' i 81-Request 1br inspection Form • f momentum SOLAR Aug 22, 2017 Town of Southold Building Department 54375 Route 25 Southold, NY 11971 Re: Stella Sakowicz 725 Peconic Lane Peconic, NY 11958 Permit# 41848 To whom it may concern, Enclosed please find the documents required for the completed solar panel installation. O� VO V-n &V A f 1) Original Electrical Certificate 2) Original Post Installation Letter If you require anything else, please do not hesitate to contact our office (631) 536-4100. Sin rely, Jes A a s RIF�C[EO'V[E DD " 45 Fairchild Ave AUG 2 8 2017 D:631.536.4100 Suite B F:732.902.6223 Plainview,NY 11803 ,��flW:momentumsolar.com TOWN OF SOUTHOLD o MC[EG'V[E DD momentum SOLAR OCT 1 7 2017 BG DEPT. TOWN OF SOUTHOLD October 13, 2017 Town of Southold Building Department 54375 Route 25 Southold, NY 11971 Re: Stella Sakowicz 725 Peconic Lane Peconic, NY 11958 Permit# 41848 To whom it may concern, Enclosed please find the documents required for the completed solar panel installation. 1) Original Post Install letter If you have any questions, please do not hesitate to contact our office (631) 536-4100. Sincerely, Yohnnie Saez Jr PROCU-1 OP ID:LM .4coRO® CERTIFICATE OF LIABILITY INSURANCE FDATE(M5/20Y 05/25/207 � 17 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les) must be endorsed. if SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Lisa MacDonald Brown&Brown Insurance NAME: 2000 Midlantic Dr.-Suite 440 AHIc°No a,:732-504-2001 ac No:7S2-504-2011 Mount Laurel,NJ 08054 ADD" RE Brian DiLuigi SS:Imacdonald@bbdvins.com INSURER(S)AFFORDING COVERAGE I NAIC# INSURERA:NewYork Marine&Gen Ins Co 116608 INSURED Pro Custom Solar LLC INSURER B:Lloyd's DBA Momentum Solar 45 Fairchild Avenue,Suite B INSURER C:Hiscox Insurance Company Inc 110200 Plainview,NY 11803 INSURER D INSURER E. INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE POLICY EFF POLICY EXP LIMITS LTR IND WVD POLICYNUMBER MM/DD MM/DD B X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS MADE OCCUR GL201600007987 12/12/2016 12/12/2017 DAMAGE TO RENTED PREMISES Ea occurrence $ 100,000 C ANE1860007.16 12/01/2016 12/01/2017 MED EXP(Any one person) $ 5,000 X Professional Liab CLAIMS MADE PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER, GENERAL AGGREGATE $ 2,000,00 POLICY 71PRO JECT F-1LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER* PROF $ 1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000 000 Ea accident A X ANY AUTO AU201700012651 04/21/2017 04/21/2018 BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS X HIRED AUTOS JC NON-OWNED PROPERTY DAMAGE $ AUTOS Per accident $ X UMBRELLA LIAR OCCUR EACH OCCURRENCE $ 5,000,000 B EXCESS LIAB CLAIMS-MADE UM201600004884 12/12/2016 12/1212017 AGGREGATE $ 5,000,000 DED I I RETENTION$ $ WORKERS COMPENSATION X PER OTH- AND EMPLOYERS'LIABILITY STATUTE ER A ANY PROPRIETOR/PARTNER/EXECUTIVE YIN WC201600012773 12112/2016 12/12/2017 EL EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? NIA (Mandatory In NH) E L DISEASE-EA EMPLOYEE $ 1,000,000 DErider SCRIPbe TION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town TownMiddle Road ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD qYOWorkers' CERTIFICATE OF a,rE Compensation Board NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Pro Custom Solar LLC 732-902-6224 DBA Momentum Solar 45 FairchildAvenue,Suite B Plainview,NY 11803 1c.NYS Unemployment Insurance Employer Registration Number of Insured Work Location of Insured(Only required if coverage is specifically limited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e„a Wrap-Up Policy) Number 271-24-2539 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) New York Marine&General Insurance Co. Town of Southold Route25 South 11971 3b.Policy Number of Entity Listed In Box"1a" Southold,NY 11WC201600012773 3c.Policy effective period 12/12/2016 to 12/1212017 3d.The Proprietor,Partners or Executive Officers are QX included.(Only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation Insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". Will the carrier notify the certificate holder within 10 days of a policy being cancelled for non-payment of premium or within 30 days if cancelled for any other reason or if the insured is otherwise eliminated from the coverage indicated on this certificate prior to the end of the policy effective period? YES Ox NO This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or after the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy Indicated on this form,if the business continues to be named on a permit,license or contract Issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,l certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Christine Howley agrintriameof Iho 6esenladve orlicensed agent of insurance carder) Approved by: (Signahi ( ,its) Title:Program Manager Telephone Number of authorized representative or licensed agent of insurance carrier: 973-532-1900 Please Note:Only insurance carriers and their licensed agents are authorized to Issue Form C405.2.Insurance brokers are NOT authorized to issue It. C-105.2(9-15) www.wcb.ny.gov PDF created with pdfFactory trial version www.pdffactorv.com A5-5uffo k=Gou de.0 SUFFOLK COUNTY DEPT,OF LABOR, LICENSING&CONSUMER AFFAIRS t 'LICENSEE, HOME IMPROVEMENT i Name;CAMERON CHRISTENSEN ;tilt '`°= CONTRACTOR I "yLICENSELicense# 2042829-DCA ice. {y Nur it ;:•' ,x1 CAMERON CHRISTENSON Expiration Date:Feb 28;'2697 .,,�✓' ' This Certifies that the sust4 8Nuee PRO CUSTOM SOLAR LLC 09A ! bearer is duly "r licensed by the Uee M.— County of Suffolk „ ,,�'"�` *1170 9-2016-ASIS* 57578-H 9aos12o9s , � ;16 ea,.,+orm.r 6svrurou wee �fLn1/7(71 R �o a Daniel W. Dunzik Architect LEED-AP Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd.Skillman, NJ.08558 908-872-3664 370 Burnt Hill Rd.Skillman, NJ.08558 908-872-3664 July 17,2017 panels shall be designed to support in excess of 30 lb. snow load by the manufacturer. Solar panels do not add any additional snow load to the existing structure.Refer to manufacturers Township of Southold specifications. 53095 Route 25 Southold,NY 11971 4. All penetrations shall be completely water tight and guaranteed for a period of ten years or the duration of the existing roof warrantee whichever is longer. Attn: Construction Official Re:Proposed Photovoltaic Solar Panel Installation 5.Positive drainage of the system shall be provided so as to not void the existing roof Stella Sakowicz warrantee. 725 Peconic Ln. Peconic NY 11958 - 6.All attachment system components shall be manufactured by"Eco-Fasten Inc."All Dear Sir: attachment system design is based on manufacturers printed design specifications. All aspects Regarding the solar panel array installation on the above referenced project please note that of this design shall be installed in strict compliance with manufacturers printed specifications. A visual inspection was performed and analysis of the existing structure was conducted.There is adequate structural capacity for the installation of the array with the following 7.All aspects of the installation shall comply with the 2015-International Residential recommendations: Code,the 2016-New York State Uniform Code Supplement,all local Code and ordinances,2014 National Electric Code NFPA 70/2014,Weathering Severe,Wind 1.The array will be installed on the existing roof. The roof is constructed of 2"x6" wood rafters . Exposure Category B,Climate Zone 4A. @ 16"O.C. spanning 13'5"max.up the slope with 1"x6" T&G wood sheathing. The new array (See Site map by contractor)will add 2.63 Lb./Sf, overall to the roof.No additional structural If you have any questions relating to this matter,please contact me at your earliest support is required for the existing roof structure. convenience. Thank you. 2.The system shall be secured to the roof using the"Ecolibrium Solar""Eco-X"®attachment system. The attachment system shall be UL 1703 approved tested. The attachments shall be OSS W oIJ min. 5/16"x 4"long stainless steel lags with a min.embedment of 2"into the rafters. Whent<`� mounted in landscape or portrait attachments shall be spaced @ 48"o.c.max.with each row —� C-LECTRRCAL staggered in roof wind zone 1.Attachments shall be spaced @ 32"o.c.max. in wind zone 2& c AP ROVED AS NOTED dl �[�[�5j ®�J �( p��0�[ 3. The maximum panel cantilever length shall be 16"in wind zone 1,2,&3 except when mounted in portrait the maximum cantilever length shall be 12" in wind zone 3 only. Provide 6 Nj, �~ :,� -�� DATE: B.P.# mil.vapor barrier between dissimilar metal fasteners.Provide water tight gasket and sealant at �. FEE: i BY; all penetrations. Attachments shall follow panel rows as specified by the system OF N 'NOTIFY BUILDING DEPARTM AT manufacturer's installation manual.The panel angle shall-match the roof slope. Daniel W. . EED- Structural Design Loads: Lie.No. 039534 FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED -Dead Loads= IOpsf(+2.6psf,New Solar Panels)= 12.6psf. FOR POURED CONCRETE RETAIN STORM WATER RUNOFF - *now Loads=3Opsf(24.5psf-factored per ASCE 7-10),Climate Zone 4A 2. ROUGH - FRAMING & PLUMBING PURSUANT TO CHAPTER 236 Wind loads= 130mph wind speed Exposure B {zones 1,2 &3(+/-)= 13psf; zone 1(-)_- COMPLY WITH ALL CODES OF 3. INSULATION 21.3psf,zone 2(-)=-35.6psf, zone 3(-)=-48psf) *Wind loads per ASCE 7-10. (-)_-35.6psf, NEW YORK STATE & TOWN CODES. FINAL - CONa:f i ION MUST OF THE TOWN CODE. zone 3(-)=-48) *Wind loads per ASCE 7-10. AS REQUIRED AND CONDITIONSO� BE COMPLETE FSR C.O. LL CONSTRUCTION SHALL MEET THE REQUIREMENT S OF THE CODES OF NEW 3. Solar modules shall be secured to the roof as per the manufacturer's specifications. Solar RK STATE. NOT RESPONSIBLE FOR modules shall`be UL-1701 rated or better. Solar Panels and attachment system shall be SIGN OR CONSTRUCTION ERRORS. designed by the manufacturer to withstand winds in excess of 130 MPH. and 50.0 PSF. Solar HOLDT n DEe N%/ OR USE 1S, UNLAWFUL Wil'h( MCERTIFICATF .OF OCOUPAN& SEE ATTACHMENT SCHEDULE PLAN KEY SYSTEM INFORMATION FOR MAXIMUM CANTILEVER COUPLING MODULE RECOM RCM-280-6MB CLAMP& momentum PV-1 COVER PAGE ATTACHMENT -• PV-2 PANEL LAYOUT INVERTER ENPHASE IQ6-60-2-US SOLAR RACKING ECOLIBRIUM ECO X RAIL-LESS SYSTEM RAFTE PV-3 LAYOUT DETAIL SYSTEM SIZE (DC) 14.28 KW SOLAR MODULE PV-4 ELECTRICAL PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 325 HIGH STREET,METUCHEN,N]08840 GENERAL NOTES: (732)902-6224 PV-5 EQUIPMENT LABELS GUTTE MOMENTUMSOLAR.COM THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS STRUCTURAL FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-10, IRC 2015 AND NEW ' ENGINEERING YORK STATE UCS 2016, NEC 2014 AND ALL LOCAL CODES &ORDINANCES. MINIMUM 6SPACING TO GUTTER DANIEL W.DUNZIK RA LEED-AP ECOLIBRIUM SOLAR ECO-X MOUNTING DETAIL LICENSE a 039534 ECOLIBRIUM SOLAR ECO X RAIL-LESS MOUNTING SYSTEM (908)872-3664 AN 18" WIDE (FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED ALONG AT LEAST INTEGRATED WITH FLASHING,COUPLINGS AND ADJUSTABLE 370 BURNT HILL ROAD CLAMP ATTACHMENTS SKILLMAN,NI 08558 SYMBOL LEGEND ONE SIDE OF THE ROOF ON THE SAME SIDE AS THE SOLAR EQUIPMENT OR ON ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ANOTHER SIDE OF THE RIDGE THAT DOES NOT HAVE SOLAR EQUIPMENT ON IT. IN ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A ADDITION AN 18" WIDE PATHWAY(FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED MAXIMUM SOLAR ARRAY ELEVATION a ANY PERSON,UNLESS ACTING UNDER THE DIRRECTION OF AW FOR MSP MAIN SERVICE PANEL ® CHIMNEYFROM AT LEAST ONE EAVE. MAXIMUM CLAMP ATTACHMENT SPACING•48' LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. SP SUB-PANEL SKYLIGHT ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE COUPLING CLAM SOLAR EQUIPMENT. \�, EO ARcy� UTILITY METER ® VENT C9 ��EC W. O INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND �� aP �0 NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. ECO-X ATTACHMENT SPACING FOR AC AC DISCONNECT O PIPE VENT LANDSCAPE OR PORTRAIT MODULES �r. Dc WEIGHT OF THE INSTALLED SYSTEM SHALL NOT EXCEED MORE THAN 5-PSF FOR ROOF WIND ZONE 1 2 3 * sF uoc UTILITY DISCONNECT FAN PHOTOVOLTAIC AND NO MORE THAN 6-PSF FOR RESIDENTIAL SOLAR HOT WATER ATTACHMENT SPACING 1R- 1R- 32" SYSTEMS. MAXIMUM CANTILEVER 16" 16" NOTE THE SPACING REQUIREMENTS IN THIS SCHEDULE 039534 Q� LOAD CENTER SATELLITE DISH LC ARE MORE STRINGENT THAN THE MANUFACTURERS ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT REQUIREMENTS �F NE�� INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A FASTENER REQUIREMENTS: N3R NEMA 311 BOX W/ENVOY-S ® FIRE SETBACKS PLUMBING PERMIT AND INSPECTION. TOTAL ARRAY AREA=893.25 SQ FT WIND LOAD:ASCE 10(SEE CALCULATIONS,STRUCTURAL CERTIFICATION)41.5 PSF MAX �'- CBCOMBINER BOX GROUND ACCESS INVERTER PLACEMENT: TOTAL UPLIFT 41.5 PSF X 893.25=37069.68 LBS CUSTOMER MODULE -► PITCH DIRECTION SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL FASTENER: INFORMATION LOCATED ON THE BACK SIDE OF EACH MODULE. LAG SCREW SPEC 203.2,8/04:(FLAT WASHERS TO BE USED WITH LAG BOLTS) STELLA SAKOWICZ LAG BOLT WITHDRAWAL VALUE 5/16"DIA.,266 LB/IN X 2-INCH THREAD DEPTH: 725 PECONIC LANE 532LB.CAP.EACH PECONIC NY 11958 BUILDING REVIEW NOTE: MINIMUM NUMBER OF LAG BOLTS REQUIRED:37069.68 LBS/532 LBS/LAG BOLT=70 (631)765-2527 MAXIMUM SPAN BETWEEN MOUNTING FEET BOLTS"X"USE 48"MAX ALLOWED AS El TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE ENCLOSED DOCUMENT FOR PER SCHEDULE JURISTICTION:SUFFOLK MINIMUM ACCEPTABLE PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS SPECIFIED BILL OF MATERIALS UTILITY:PSE&G IN THE BUILDING AND/OR RESIDENTIAL CODE OF THE STATE OF NEW YORK. UTILITY ACCT#:9646538201 RECOM RCM-280-6MB THISREVIEW DOES NOT GUARANTEE COMPLIANCE OF THAT CODE. THAT MODULES 51 UTILITY METER#:20812439 2803WATT MODULE I� RESPONSIBILITY IS GUARANTEED UNDER THE SEAL AND SIGNATURE OF THE NEW INVERTERS 51 64. 7 X 39.06 X 1.38 YORK LICENSED DESIGN PROFESSIONAL OF RECORD. THAT SEAL AND SIGNATURE PV SYSTEM SEE DATASHEET) HAS BEEN INTERPRETED AS AN ATTESTATION THAT, TO THE BEST OF THE LICENSEE'S CLAMP ASSEMBLY 128 BELIEF AND INFORMATION, THE WORK IN DOCUMENT IS: INFORMATION COUPLING ASSEMBLY 66 SYSTEM SIZE(DC):14.28 KW CLIMATIC & GEOGRAPHIC DESIGN 1. ACCURATE BONDING CLIP 9 51 MODULES:RECOM RCM-280-6MB CRITERIA TABLE R301.2(1) 2. CONFORMS WITH GOVERNING CODES APPLICABLE AT THE TIME OF THE SKIRTS 14 51 INVERTERS: ENPHASE IQ6-60-2-US SUBMISSION. GROUND SNOW LOAD 25 LBS/SF 3. CONFORMS WITH REASONABLE STANDARDS OF PRACTICE AND WITH VIEW TO LOAD CENTER 1 SPEED (MPH) 135 MPH THE SAFEGUARDING OF LIFE, HEALTH, PROPERTY AND PUBLIC WELFARE IS THE RESPONSIBILITY OF THE LICENSEE. 125A FUSIBLE AC DISCONNECT 1 TOPOGRAPHIC EFFECTS B STRUCTURAL STATEMENT: 70A FUSES 2 PR03ECTINFORMATI0N SPECIAL WIND REGION _ NO 125A LINE TAPS 2 INITIAL DATE:7/17/2017 DESIGNER:MA THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE-NEW-LOADS IMPOSED-BY REV: DATE: DESIGNER: WIND BORNE DEBRIS ZONE 2 THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT&SHEAR.EXISTING RAFTER 20A BREAKERS 4 REV: DATE: DESIGNER: SEISMIC DESIGN CATEGORY -C SIZES & DIMENSIONS CONFIRM TO IRC-2015 TABLE R802.5(1)-RAFTER SPANS. 15A BREAKER 1 CLIMATE ZONE 4A MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED NEW YORK STATE CODE ENVOY-S 1 COVER PAGE WIND EXPOSURE CATEGORY B REQUIREMENTS FOR THE DESIGN CRITERIA OF THE TOWN. NEMA 311 PVC BOX 1 PV- 1 SCALE 1/8" V-01' ROOF MODULE COUNT TILT AZIMUTH SHADING R1 35 24" 225° 92% R2 16 24" 45° 94% momentum SOLAR PECONIC LN PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 325 HIGH STREET,METUCHEN,N]08840 2)902-6224 MOME3NTUMSOLAR COM STRUCTURAL ENGINEERING � FRONT OF RESIDENCE DANIEL W.DUNnK RA LEED-AP LICENSE#039534 OSS (\!� (908)872-3664 370 BURNT HILL ROAD SKILJ.h1AN,W 08558 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND <:D AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECR OF A LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. \�\tiRED qRc �G NOEL W.pCi 'Sj� GROUND ACCESS GUTTER } (TYP) TA 039534'` MSP OF 'YEY' ❑ ❑ ❑ O DC N3R LC CUSTOMER ❑ ❑ ❑ ❑ INFORMATION R2 FIRE SETBACK t (18" VENTILATION, STELLA SAKOWICZ ❑ ❑ ❑ ❑ I / 725 PECONIC LANE RIDGE 36" ROOF ACCESS) PECONIC NY 11958 ❑ ❑ ❑ ❑ ❑ ® (631)765-2527 1URISTICTION:SUFFOLK FIRE SETBACK UTILITY: PSE&G UTILITY ACCT#:9646538201 36" ROOF ACCESS)VENTILATION, UTILITY METER#:20812439 36" PV SYSTEM ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ INFORMATION SYSTEM SIZE(DC): 14.28 KW 51 MODULES:RECOM RCM-280-6MB ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ GUTTER 51 INVERTERS:ENPHASE IQ6-60-2-US GROUND ACCESS (TYp) FR---ll ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 0 PROJECT INFORMATION INITIAL DATE:7/17/2017 DESIGNER:MA SOLAR INSTALLER NOTES: REV: DATE: DESIGNER: NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED r REV: DATE: DESIGNER: PANEL LAYOUT- PV-2 ROOF FRAMING ACTUAL SPAN SHEATHING COLLAR TIES KNEE WALL SHINGLE TYPE LAYERS 111 2"X 6" RAFTER 16"OC 13'-5" TONGUE AND GROOVE N/A N/A ASPHALT 1 R2 2"X 6" RAFTER 16"OC 13'-5" TONGUE AND GROOVE N/A N/A ASPHALT 1 momentum - ARRAY 1 LAYOUT DETAIL SOLAR ��-ALE: 3/16" = 1'-0" 48'-7" 01 PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR TILT: 24* 325 HIGH STREET,METUCHEN,NJ 08840 AZIMUTH: 2250 (732) 24 MOMENTUMSOLASOLAR.COM SHADING: 92% STRUCTURAL 1'-112" ENGINEERING DANIEL W.DUNZIK RA LEED-AP LICENSE F 039534 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 664 3 0 BURN HIL 370 BURNT HILL ROAD SKNIMAN,NJ 08558 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ANY PERSON,UNLESS ACTING UNDER THEOF A LICENSED ARCHITECT,TO ALTER AN ITEM INN ANY ANY WAY. 13'-21" n� 039534 Q� 0'-6° OF NES� 5'-9" 0'-6" SOLAR INSTALLER NOTES: ir NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED CUSTOMER INFORMATION R2 - ARRAY 2 LAYOUT DETAIL SCALE: 3/16t1 = 1'-0" STELLASAKOWICz NIC LANE TILT: 24` lo 27'-0" PECONIC725 ONY 1 958 AZIMUTH: 45* (631)765-2527 SHADING: 94% 1'-6" JURISTICTION:SUFFOLK UTILITY:PSE&G UTILITY ACCT#:9646538201 ® ❑ ❑ ❑ ❑ ❑ UTILITY METER M 20812439 PV SYSTEM 8'-11" ❑ ❑ ❑ ❑ INFORMATION SYSTEM SIZE(DC): 14.28 KW 13'-21" 51 MODULES: RECOM RCM-280-6MB 51 INVERTERS: ENPHASE IQ6-60-2-US ❑ ❑ ❑ PROJECT INFORMATION INITIAL DATE:7/17/2017 DESIGNER:MA REV: DATE: DESIGNER: REV: DATE: DESIGNER: LAYOUT DETAIL SOLAR INSTALLER NOTES: 0'-6" NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED PV-3 51 RECOM RCM-280-6MB 280W MODULES PAIRED WITH 51 ENPHASE IQ6-60-2-US MICRO-INVERTERS momentum r \) SOLAR NEMA 3R BOX '�,__'.IRANCH CIRCUIT A ENPHASE EXISITING SQUARE D 100A 16 MICRO-INVERTERS BRANCH CIRCUIT E"°"s MAIN SERVICE PANEL 240 V PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR BRANCH CIRCUIT B 325 HIGH STREET,METUCHEN,N]08840 15 MICRO-INVERTERS 125 AMP (732)902-6224 BRANCH CIRCUIT C LOAD CENTER MAIN BREAKER: 100A MOMENTUMSOLAR.COM 10 MICRO-INVERTERS + _ + _ + _ INE SIDE STRUCTURAL BRANCH CIRCUIT D HOT TAP 10 MICRO-INVERTERS ENGINEERING DANIEL W.DUNZIK RA LEED-AP LICENSE#039534 ■ ■ ■ 3 08) RNTHIL _ 370 BURNT HILL ROAD SQUARE-D 125A 172-3664 00A SKILLMAN,N]08558 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND S 3A FUSIBLE AC UTILITY AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE DISCONNECT METER COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. 7oA ��� ELECTRICIAN ROOF 15A BREAKER(ENVOY) JUNCTION 20A BREAKER(A) TERMINATION CAP 1 BOX 2A-D 20A BREAKER(B) 3 70A FUSES POWER INSTALLED ON 20A BREAKER(C) 4 -GROUND GRID G�5 N*tit_w 20A BREAKER(D) P wTG�� END OF CABLE \, cin a 4. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE Nom` '=° - ELECTRICAL NOTES: LARGEST BRANCH CIRCUIT IN SYSTEM.OTHER BRANCH CIRCUITS �� 0 9534 O CALCULATIONS FOR VOC,VMAX, IMP AND ISC HAVE BEEN WILL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN. O �( F_CULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON F NEIN _ice.IRAE 2%HIGH AND EXTREME MINIMUM TEMPERATURE COEFICIENTS. 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2014 ARTICLE 310 CU R 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 INFORMATION paragraph C). THE GROUND IS CARRIED AWAY FROM THE GROUNDING LUG 6.ALL EQUIPMENT INSTALLED IS RATED AT 90°C STELLA SAKOWICZ USING #6 BARE COPPER WIRE. 7. INVERTER NOC(NOMINAL OPEN CURRENT)OBTAINED FROM 725 PECONIC LANE 3. THIS SYSTEM COMPLIES WITH NEC 2014 EQUIPMENT DATASHEET PECONIC NY 11958 (631)765-2527 URISTICTION:SUFFOLK TILITY: PSE&G TILITY ACCT#:9646538201 TILITY METER#:20812439 PV SYSTEM INFORMATION SYSTEM SIZE(DC):14.28 KW 51 MODULES: RECOM RCM-280-6MB Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire 51 INVERTERS: ENPHASE IQ6-60-2-US Wire Tag' Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC(A) Correction Current(A) Size Type 1 Open Air 4 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 16 0.96 1.25 19.20 12 AWG Trunk Cable 2A 1" PVC 3 10 AWG THWN-2 90°C- 40 0.96 0.7 26.88 16 0.96 1.25 19.20 08 AWG THWN-2 PRO)ECrINFORMATION 213 1" PVC 3 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 15 0.96 1.25 18.00 08 AWG THWN-2 INITIAL DATE:7/17/2017 DESIGNER:MA REV: DATE: DESIGNER: 'v.ZC 1" PVC 3 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 10 0.96 1.25 12.00 08 AWG THWN-2 REV: DATE: DESIGNER: 13 1" PVC 3 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 10 0.96 1.25 12.00 08 AWG THWN-2 ELECTRICAL 3 1" PVC 3 06 AWG THWN-2 90°C 75 0.96 1 72.00 51 0.96 1.25 61.20 08 AWG THWN-2 4 1" PVC 3 06 AWG THWN-2 90°C 75 0.96 1 72.00 51 0.96 1.25 61.20 08 AWG THWN-2 PV-4 TAG LABEL QUANTITY LOCATION NOTE EXAMPLES 1 AT EVERY SEPARATION BY momentum n 12 DC CONDUITS SOLAR ENCLOSURES/WALLS/ ! PARTITIONS/CEILINGS 1 FLOORS OR NO MORE THAN 10' O c • • •willEI PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR �' "�� �I • 325 HIGH STREET,METUCHEN,NJ 08840 (732)902-6224 MOMENTUMSOLAR.COM STRUCTURAL ENGINEERING © 1 AT ANY JUNCTION BOX OR DC ", F ';.,. e -!�'r DANIEL W.DUNZIK RA LEED-AP 1 COMBINER BOX ;a w LICENSE A 039534 A.. 4�4...�s;; COMBINER IF USED O ? ;r& M .?. -' (908)872-3664 370 BURNT HILL ROAD _ (! SKILLMAN,NI 08558 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND i; a -~➢_. _ '' `� AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR �:- ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. ' \��ePED q�C 1 AT ANY JUNCTION BOX OR DC l(iG P��BL W O(i y/), © 1 JUNCTION BOX COMBINER IF USED µ�< U, jM A '`t. M.- 39534 OQ� }e w CUSTOMER 1 OF EACH AT FUSED AC DISCONNECT © I N FO RMATIO N Q 1 AC DISCONNECT COMPLETE VOLTAGE AND CURRENT VALUES ON . � STELLA SAKOWICZ DISCONNECT LABEL ' " 725 PECONIC LANE PECONIC NY 11958 (631)765-2527 JURISTICTION:SUFFOLK UTILITY: PSESIG UTILITY ACCT#:9646538201 O UTILITY METER-#:20812439 PV SYSTEM OE 1 MAIN DISCONNECT 1 OF EACH AT BUILDING MAIN �.. �,�,'`.�,;f'°F INFORMATION PANEL DISCONNECT PANEL � tl -gn N - _ SYSTEM SIZE(DC): 14.28 KW 51 MODULES:RECOM RCM-280-6MB 51 INVERTERS: ENPHASE IQ6-60-2-US ate. =4 ' PROJECT INFORMATION INITIAL DATE:7/17/2017 DESIGNER.MA O 1 UTILITY METER 1 AT UTILITY METER REV: DATE: DESIGNER: REV: DATE: DESIGNER: EQUIPMENT LABELS PV-5 The new EcoX is an innovative rail less racking system, proven •;„'-"``...�-�,,..�� `��`t•� z�k`;.,;r-fit, -�.:,1r;.w �:ri-',''�.�"�'�$'� to organize the installation 4-`•'' .rro - - s`'8 C.--."-�`•`;.'"„- '.,,,....�-x e., :�y� � r..:_ '..,_ _ rocess. The flexible desi n _ - _ "• _ J�.tiJ '.,Ari; offers a clean aesthetic t simplified logistics,and delivers y}< - � h3!d �I •Y'�s-G�•� < - r•: .��s',..<:�j: ::;:;a� "s4.t,%F;�r •,r: _"' "``` •-+' -fie ..w' I i9., - ..`i�x;�",.,. •i,s .3 ,t:•,c i% `ni R a higher quality installation at a lower costwatt er . p - }=- Aesthetic Design Cable Management .�_�.. �� � .^',� '�• r _ + .� - {,. +' _.,.�•�,;::,; „}S ..• ��.=1`-:,,E-' A wide range of adjustment makes it easy to install a Whether installing with Microinverters, Power designed to Optimizers, orStri �Y;-AJ;:,;r ,.�.; �;.; ,�_ _ ,�, _ _ ',,;5-�;_ . <}<�:ry-�r rte', ;- •; straight, level system. Components are desi n d ng Inverters, EcoX provides wire -creates into the array, and the aesthetic skirtmanagement provisions to both prep the modules,es, and a Finished look. Alternative) a skirt Free option is to route homerun ortrunk y, p cables throughout the array, _; r '"'-' = ;: n1 VN• available to provide a more traditional look. •��:�:_.° 0...i°' - =;°-` x"{= '.; .c:•",,' '-".''�!�:' ter'+.��{.:r-!_;;`•c,ii�z;ec'f."y 3Yt 11-/�.=3f-: �' h c'= _ r'_2:...»r- .•-xt•,.r � tet._ -q�,�.1x�z,,{, F$--.`?r'�•i:,_ "JoT✓.a• _ � _,.��'1s./ :-T==fi f7:ff=fl?�'s .�.:t? ..+=ia:-•-ci, o-:..-+,�kr�Y�S•� •'r'-' i•?\'y'P*�"`,v `�,°^ 5':•s'�.`4 '.»i`' x��, `si;t�`.. .r""`'` � " -.ice'-/`.fi°' s :.p a�°t;. ;,'z..�+'• '7. ,t...s: : '.. ::.^:�a^:,'-`,i^�. .-c,`rx-r;,:�:.' yv„- k,~ - y�#fY ' - "..;�_,-''`ww•,.S�J�. .s ^FSS?-Fl�rr�ri�'?�:.�-.r�:>.,-u'� „p� _:t-•s��„„�' ,s. -2'x: S•^'� � �:k c. ,`;�•."?�,- _' +a«�:-:'S�.a_:��.:�:w'="''-`,-. ./ rmtmnsms` \ t ' ;:.0 ' ,- „✓�` E a: lP11 :"`ate "'� -A 11 Layout r .�.� •`' '°-i` _ _ -• r:y. r> Dew-w-+xewmtms»waam,..�..e . _ -�•'.'.].'..at..�'.:.---- 'v°^r`�''". _ z}�' _ __ may"-A:'`.--'�..: _ ._"�.t� `s.c�g .pr��" ',qt �f..�' - ,:'n y� • P '"...;.•y,..____�//p�}tl,'i*t.;.X-. - _ -' °i, ."fin';'"'K. ,-�• '�z, �°.7?`� �" \..•_ t'• Efw -„f. A .ha 1 ,et. _ _ -�F. '9,' Y•r' r§R -�"5-.�w ti•'.,.w� SFi. .r s;^^'•" .N •-4 Y �iP,s�-` +�i` {qq':^}=... •�"ir.. Tom:'...,,fit `.•rt,...:...si....t,' ..a°s - "°"S �, �t�;��' X+ «i«xtl?•'"''. -E _ _fi�.3 wiJY6.".� 'Td r �� �r$ .���. ��r^•'-`•x+,+•TM'-L ..r.•,n � � - rF Flexible System Design Single Point Grounding The EcoX Estimator is a powerFul racking system EcoX and approved modules create a continuously design tool.The user inputs all site conditions and bonded system. The installer can connect a finished r• t "f:. "'fib xc ., can layout multiple roof surfaces. The EcoX Estimator array to ground with a single bonding lug. outputs a site specific design package with engineering specs and bill ofmaterials.- Technical Specifications Rackin' :coni onents:AluiiiinurriF`Jstainless hacduwafe dark 1 Mate - n s _ bronze+anodize uF 'ersurface' mill-l7nishdower'su Fast. Simple. . .}.- ' P �,- :F1'ashjn's:Aluminum black nwdercoated'finjs}i: ' g, R Modules drop in From above Universal components mount to The Ecolibrium Field support team "II` ~" and there is never a need to standard Framed modules,With oFFers on-site installation training Grounding/Bonding Validation UL2703 - see installation manual For specific module approvals o walk on modules. a single socket size and a wide and ongoing technical support. - reach over r g g g PP - L- - _ z; �nyy E_ - - =Fir`e:Re"sistanceUalidat'o r = = t rr .',._.:- ---'U L-27 'e 1'and T' ' -:2 'odul'es Pre-assembled components range oFadjustment, it is quick And From project planning to - >F-.•_>_' _ ._ '--.;._-;A' _ = i.rYP.y__, , _ = a� ;:., 4 : and quick connections make and easy to install any array logistics to installation, we are Mechanical Load Validation UL27O3 - see installation manual For specific module approvals EcoX easy to install, with a clean, Finished look. dedicated to customer service. 5. �. Flashin `Validation, ES>AC286.UL441 Rain'Test`'for RooFFla -`� Adjustabil!ty 1" vertical range, 3.5" North/South range, _ ® connect anywhere in East/West direction ____ _ -.'. X73 w •}' _^t-'- ar--rant 'r` _ +15 s r- �o sales(a7ecol!briumsolarcam US 740-249-1877 www.ecol!br!umsolarcom EcolibriurnSolar salesPecol!br!umsolarcom US 740-249-1877 wwwecol!br,umsolarcom vEeolibriumsolar Data Sheet Enphase Microinverters Enphase IQ 6 and IQ 6+ Microinverters INPUT DATA(DC) IQ6-60-2-US AND IQ6-60-5-US IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US Commonly used module pairings' 195 W-330 W+ 235W-400W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules The high-powered smart grid-ready Maximum input DC voltage 48V 62 V Enphase En hase IQ 6 Micro" 16 62 and En hase IQ 6+ Micro"" Peak power tracking voltage V-37V 27V- V p p Operating range 16 V-48 V 16 V-62 V IQ 6 G and G L��, dramatically simplify the installation process while Min/Max start voltage 22 V/48 V 22 V/62 V �t Q achieving the highest efficiency for module-level Max DC short circuit current(module Isc) 15 A 15 A Microinverters power electronics. Overvoltage class DC port II II DC port backfeed under single fault 0 A 0 A Part of the Enphase IQ System,the IQ 6 and IQ PV array configuration 1 x 1 ungrounded array;No additional DC side protection required, AC side protection requires max 20A per branch circuit 6+ Micro integrate seamlessly with the Enphase OUTPUT DATA(AC) IQ6-60-2-US AND IQ6-60-5-US IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US IQ Envoy', Enphase Q Aggregator', Enphase IQ Peak output power 240 VA 290 VA Battery",and the Enphase Enlighten" monitoring Maximum continuous output power 230 VA 280 VA Nominal voltage/rangez 240 V/211-264 V 208V(14))/183-229V 240 V/211-264 V 208 V(14))/183-229 V and analysis software. Nominal output current 0.96 A 1.11 A 1.17 A 1.35 A The IQ 6 and IQ 6+Micro extend the reliability Nominal frequency 60 Hz 60 Hz standards set forth by previous generations and Extended frequency range 47-68 Hz 47-68 Hz Power factor at rated power 1.0 1.0 undergo over a million hours of power-on testing. Maximum units per 20 A branch circuit 16(240 VAC) 13(240 VAC) Enabling Enphase to provide an industry-leading 14(single-phase 208 VAC) 11 (single-phase 208 VAC) warranty of up to 25 years. Overvoltage class AC port III III AC port backfeed under single fault 0 A 0 A Power factor(adjustable) 0.7 leading..0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V(10) @240 V @208 V(1410) Easy to Install CEC weighted efficiency 97.0% 96.5% 97.0% 96.5% MECHANICAL DATA • Lightweight and simple Ambient temperature range -40°C to+650C • Faster installation with improved two-wire Relative humidity range 4°i°to 100%(condensing) r '' cabling Connector type MC4 or Amphenol H4 UTX Built-in rapid shutdown compliant(NEC 2014) Dimensions(WxHxD) 219 mm x 191 mm x 37.9 mm(without bracket) Weight 1.5 kg(3.3 lbs) -ia � M y4 Productive and Reliable Cooling Natural convection-No fans Approved for wet locations Yes 4 Optimized for high powered 60-cell and 72- Pollution degree PD3 tet; cell*modules Environmental category/UV exposure rating Outdoor-NEMA 250,type 6(11367) • More than a million hours of testing FEATURES Class II double-insulated enclosure Communication Power line Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Smart Grid Ready Compliance UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 Complies with fixed power factor,voltage and This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and frequency ride-through requirements NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC • Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions. grid requirements 1 No enforced DC/AC ratio See the compatibility calculator at enphase com/en-us/support/module-compatibility Configurable for varying grid profiles 2.Nominal voltage range can be extended beyond nominal if required by the utility L *The IQ 6+Micro is required to support 72-cell modules To learn more about Enphase offerings,-visit enphase.com y ® E N P H A S E 2017 Enphase Energy All rights reserved All trademarks or brands used are the property of Enphase Energy,Inc E N P H AS E To learn more about Enphase offerings,visit enphase.com !/ 2017-05-01 u e FRECC3M RECMM I , MONO MONO 250 260,270,280 RCM—xxx-6MB (xxx=250-280) 9 Rated Power 250W 260W 270W 28OW B —I°°m —ecowrm 2 —Comm. Power Tolerance. 0%/+5W 0%/+5W 0%1+5W 0%/+5W -1. b 2°°Yl/m Max.Power Voltage 31.30V 31.70V 3212V 32 50V ' t.- •t'esi - �, i'tCt.-s� `:r.:y':� , ;r-,.. + .3; -=,."�'-':,s••ar: g::," .�;;.r. (Ump)• 34 3 8.09A 8.32A 845A 8 67AMax.Power Current(Imp) Open Circuit Voltage Nod 37.92V 38.52V 38 76V 39 20V 1 Short Circuit Current(Isc): 8.51A 866A 8.78A 8 99A o s to is °na o zs ao 35 ua The module relative power loss at low light irradiance of 200WItTi is less than 3% Pmax(NOCT): 200.8W 208 8W 216.6W 223.9W 7.7 Y Module Efficient Ji ^i" 15 4% 16 0% 16 6% 17 7% Y ,Aw �f Tr Max Serres Fuse: 15A 15A 15A 15A Pmax Temperature Coefficient -0.39%/ C Voc Temperature Coefficient -0.32%/°C 1000V DC(UL) Max.System Voltage: 1000V DC(IEC)/ Isc Temperature Coefficient +0.05%/°C Tested at Standard Test Conditions Measurement tolerances±3% Operating Temperature -40-+85'C Nominal Operating Cell Temperature(NOCT) 45±2 IC - z ;: ,:. ti••'Ir ;.,- ;, ;�' � •r'�E s ��5 Dimensions 1640mm x 992mm x 35mm Container - 20'GP 40'HC Frame Anodized aluminum� Pieces per Pallet 29 or 30 29 or 30 Weight 19 kgs Pallets per Container 12 28 Front Glass 3 2 mm AR low iron tempered glass Pieces per Container 348 or 360 812 or 840 Output Cables: TUV(2Pfgl 169 2007).UL 4703 UL44 4 0 mmz ��� �y- -< •, :: (0.006 m2).symmetrical lengths(-J 1000mm .- a° d" and(+)1000 mm,MC4 type connectors Standard tests UL1703,IEC 61215,IEC 61730µ `- F Quality tests ISO 9001 2008,IS0 14001 2004,ISO17025 2005 , ' rr: Class C Fire Rating,conformity to CE.PV CYCLE, Certifications Salt Mist and Ammonia Corrosion Extreme wind and Module certified to withstand extreme wind rn _ __ - 1640mm _ �I snow loads testing 12400 Pascal]and snow loads 15400 Pascal) - I Positive tolerance Guaranteed positive tolerance of up to 5W Junction Box IP67 Rated,3 diodes - 1000mm Warranties •10-year limited product warranty E ! •25-year transferable linear power output warranty E Bla^(v'I ,rL(\ /1C "' a LINEAR PERFORMANCE WARRANTY P P 2 ;;g;Yr:.� A�i6onaivaluehom _ RECOMS ,wa�T .l_._ Yeats 0 I 5 10 1b 20 2b Manufactured {/-P�1 Anp-PIC f4L Proven by Independent + - t Guaranteed Specifications are subject to change without further notification `CP-! Tef I1� Release lot R-02 g21 m EU hnoloyy Engineering Tests `�' Positive Power .. Dealer: a® E C� sp iEa: CEC } recom-solar.com Daniel W. Dunzik Architect LEED-AP Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd. Skillman, NJ.08558 908-872-3664 370 Burnt Hill Rd.Skillman, NJ. 08558 908-872-3664 July 17, 2017 panels shall be designed to support in excess of 30 lb. snow load by the manufacturer. Solar panels do not add any additional snow load to the existing structure. Refer to manufacturers Township of Southold specifications. 53095 Route 25 Southold,NY 11971 4. All penetrations shall be completely water tight and guaranteed for a period of ten years or the duration of the existing roof warrantee whichever is longer. Attn: Construction Official Re: Proposed Photovoltaic Solar Panel Installation 5. Positive drainage of the system shall be provided so as to not void the existing roof Stella Sakowicz warrantee. 725 Peconic Ln. Peconic NY 11958 6. All attachment system components shall be manufactured by"Eco-Fasten Inc."All Dear Sir: attachment system design is based on manufacturers printed design specifications. All aspects Regarding the solar panel array installation on the above referenced project please note that of this design shall be installed in strict compliance with manufacturers printed specifications. A visual inspection was performed and analysis of the existing structure was conducted. There is adequate structural capacity for the installation of the array with the following 7. All aspects of the installation shall comply with the 2015-International Residential recommendations: Code,the 2016-New York State Uniform Code Supplement,all local Code and ordinances,2014 National Electric Code NFPA 70/2014, Weathering Severe, Wind 1. The array will be installed on the existing roof. The roof is constructed of 2"x6"wood rafters Exposure Category B,Climate Zone 4A. @ 16" O.C. spanning 13' 5"max.up the slope with 1"x6"T&G wood sheathing. The new array (See Site map by contractor)will add 2.63 Lb./Sf. overall to the roof.No additional structural If you have any questions relating to this matter,please contact me at your earliest support is required for the existing roof structure. convenience. Thank you. 2. The system shall be secured to the roof using the"Ecolibrium Solar""Eco-X"® attachment system. The attachment system shall be UL 1703 approved tested. The attachments shall be E� ARC min. 5/16"x 4"long stainless steel lags with a min. embedment of 2"into the rafters. When �5 ���W ouNz� mounted in landscape or portrait attachments shall be spaced @ 48"o.c. max. with each row staggered in roof wind zone 1. Attachments shall be spaced @ 32"o.c. max. in wind zone 2 & 3. The maximum panel cantilever length shall be 16"in wind zone 1,2, &3 except when mounted in portrait the maximum cantilever length shall be 12"in wind zone 3 only. Provide 6 mil. vapor barrier between dissimilar metal fasteners. Provide water tight gasket and sealant at �a all penetrations. Attachments shall follow panel rows as specified by the system �-�/ 03953A y manufacturer's installation manual. The panel angle shall match the roof slope. Dam ED-AP Structural Design Loads: Lic.No. -Dead Loads= 10psf(+2.6psf,New Solar Panels)= 12.6psf. - Snow Loads=30psf(24.5psf-factored per ASCE 7-10), Climate Zone 4A - *Wind loads= 130mph wind speed Exposure B {zones 1,2 &3(+/-) = 13psf; zone 1(-)_- 21.3psf,zone 2(-)=-35.6psf,zone 3(-)=-48psf1 *Wind loads per ASCE 7-10. (-)_-35.6psf, zone 3(-)_-481 *Wind loads per ASCE 7-10. r 3. Solar modules shall be secured to the roof as per the manufacturer's specifications. Solar modules shall be UL-1701 rated or better. Solar Panels and attachment system shall be designed by the manufacturer to withstand winds in excess of 130 MPH. and 50.0 PSF. Solar SEE ATTACHMENT SCHEDULE PLAN KEY SYSTEM INFORMATION FOR MAXIMUM CANTILEVER COUPLING MODULE RECOM RCM-280-6MB CLAMP& momentum PV-1 COVER PAGE INVERTER ENPHASE IQ6-60-2-US ATTACHMENT PV-2 PANEL LAYOUT RACKING ECOLIBRIUM ECO X RAIL-LESS SYSTEM RAFTER ®��°� PV-3 LAYOUT DETAIL SYSTEM SIZE (DC) 14.28 KW SOLAR MODUL PV-4 ELECTRICAL PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 325 HIGH STREET,METUCHEN,NJ 08840 (732)902-6224 PV-5 EQUIPMENT LABELS GENERAL NOTES: GUTTE MOMENTUMSOLAR.COM 4 THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS STRUCTURAL FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-10, IRC 2015 AND NEW ENGINEERING YORK STATE UCS 2016, NEC 2014 AND ALL LOCAL CODES &ORDINANCES. MINIMUM6"SPACING TO GUTTER E DANIEL W.DUNZIK RALEER-AP ECOLIBRIUM SOLAR ECO-X MOUNTING DETAIL LICENSE u 039534 ECOLIBRIUM SOLAR ECO X RAIL-LESS MOUNTING SYSTEM (908)872-3664 AN 18" WIDE (FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED ALONG AT LEAST INTEGRATED WITH FLASHING,COUPLINGS AND ADJUSTABLE 370 BURNT HILL ROAD CLAMP ATTACHMENTS SKILLMAN,NI 08558 SYMBOL LEGEND ONE SIDE OF THE ROOF ON THE SAME SIDE AS THE SOLAR EQUIPMENT OR ON ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND ON SPANS ANOTHER SIDE OF THE RIDGE THAT DOES NOT HAVE SOLAR EQUIPMENT ON IT. IN ATTACHMENTS TO MEET LOCAL AND STATE BUILDCALCULATIONS FOR SOLARTING CODE & ADDITION AN 18" WIDE PATHWAY(FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED MAXIMUM SOLAR ARRAY ELEVATION 42' COMPLIANCE.WARNING THAT UIS RTHEVIOLATIONDIRECTION IOTHE LAW FOR MAXIMUM CLAMP ATTACHMENT SPACING 48' ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A MSP MAIN SERVICE PANEL CHIMNEY FROM AT LEAST ONE EAVE. LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. SP SUB-PANEL z SKYLIGHT ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE COUPLINGCLAM SOLAR EQUIPMENT. \S�ERED ARCS, OM UTILITY METER ® VENT INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND C7 PN�EL W OU,y2 Vx� Ac_71 NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. ECO-X ATTACHMENT SPACING FOR �� • ��sv— %� DC AC DISCONNECT 0 PIPE VENT LANDSCAPE OR PORTRAIT MODULES WEIGHT OF THE INSTALLED SYSTEM SHALL NOT EXCEED MORE THAN 5-PSF FOR ROOF WIND ZONE 1 1 1 Fu UTILITY DISCONNECT � FAN PHOTOVOLTAIC AND NO MORE THAN 6-PSF FOR RESIDENTIAL SOLAR HOT WATER MAXIMUM CANTILEVER ATTACHMENT SPACING 48" 32" 32" 16" 16" 12" SYSTEMS. NOTE THE SPACING REQUIREMENTS IN THIS SCHEDULE v' LC LOAD CENTER SATELLITE DISH ARE MORE STRINGENT THAN THE MANUFACTURERS ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT REQUIREMENTS �J� 039534 �Q INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A FASTENER REQUIREMENTS: p N3R NEMA 3R BOX W/ENVOY-S ® FIRE SETBACKS PLUMBING PERMIT AND INSPECTION. TOTAL ARRAY AREA=893.25 SQ FT F NES WIND LOAD:ASCE 10(SEE CALCULATIONS,STRUCTURAL CERTIFICATION)41.5 PSF MAX CB COMBINER BOX GROUND ACCESS INVERTER PLACEMENT: TOTAL UPLIFT 41.5 PSFX893.25=37069.68 LBS CUSTOMER MODULE PITCH DIRECTION SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL FASTENER: INFORMATION LOCATED ON THE BACK SIDE OF EACH MODULE. LAG SCREW SPEC 203.2,8/04:(FLAT WASHERS TO BE USED WITH LAG BOLTS) STELLA SAKOWICZ LAG BOLT WITHDRAWAL VALUE 5/16"DIA.,266 LB/IN X 2-INCH THREAD DEPTH: 725 PECONIC LANE 532LB.CAP.EACH PECONIC NY 11958 BUILDING REVIEW NOTE: MINIMUM NUMBER OF LAG BOLTS REQUIRED:37069.68 LBS/532 LBS/LAG BOLT=70 (631)765-2527 MAXIMUM SPAN BETWEEN MOUNTING FEET BOLTS"X"USE 48"MAX ALLOWED AS TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE ENCLOSED DOCUMENT FOR PER SCHEDULE JURISTICTION:SUFFOLK MINIMUM ACCEPTABLE PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS SPECIFIED BILL OF MATERIALS UTILITY: PSE&G IN THE BUILDING AND/OR RESIDENTIAL CODE OF THE STATE OF NEW YORK. UTILITY ACCT#:9646538201 RECOM RCM-280-6MB THISREVIEW DOES NOT GUARANTEE COMPLIANCE OF THAT CODE. THAT MODULES 51 UTILITY METER#:20812439 280�WATT MODULE �I RESPONSIBILITY IS GUARANTEED UNDER THE SEAL AND SIGNATURE OF THE NEW INVERTERS 51 64. 7 X 39.06 X 1.38 YORK LICENSED DESIGN PROFESSIONAL OF RECORD. THAT SEAL AND SIGNATURE PV SYSTEM SEE DATASHEET) HAS BEEN INTERPRETED AS AN ATTESTATION THAT, TO THE BEST OF THE LICENSEE'S CLAMP ASSEMBLY 128 BELIEF AND INFORMATION,THE WORK IN DOCUMENT IS: INFORMATION COUPLING ASSEMBLY 66 SYSTEM SIZE(DC): 14.28 KW CLIMATIC & GEOGRAPHIC DESIGN 1. ACCURATE BONDING CLIP 9 51 MODULES: RECOM RCM-280-6MB CRITERIA TABLE R301.2(1) 2. CONFORMS WITH GOVERNING CODES APPLICABLE AT THE TIME OF THE SKIRTS 14 51 INVERTERS:ENPHASE IQ6-60-2-US SUBMISSION. GROUND SNOW LOAD 25 LBS/SF 3. CONFORMS WITH REASONABLE STANDARDS OF PRACTICE AND WITH VIEW TO LOAD CENTER 1 SPEED (MPH) 135 MPH THE SAFEGUARDING OF LIFE, HEALTH, PROPERTY AND PUBLIC WELFARE IS THE RESPONSIBILITY OF THE LICENSEE. 125A FUSIBLE AC DISCONNECT 1 TOPOGRAPHIC EFFECTS B STRUCTURAL STATEMENT: 70A FUSES 2 PRO]ECT INFORMATION SPECIAL WIND REGION NO 125A LINE TAPS 2 INITIAL DATE:7/17/2017 DESIGNER:MA THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE NEW LOADS IMPOSED BY REV: DATE: DESIGNER: WIND BORNE DEBRIS ZONE 2 THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT&SHEAR.EXISTING RAFTER 20A BREAKERS 4 REV: DATE: DESIGNER: SEISMIC DESIGN CATEGORY C SIZES &DIMENSIONS CONFIRM TO IRC-2015 TABLE R802.5(1)-RAFTER SPANS. 15A BREAKER 1 CLIMATE ZONE 4A MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED NEW YORK STATE CODE ENVOY-S 1 COVER PAGE WIND EXPOSURE CATEGORY B REQUIREMENTS FOR THE DESIGN CRITERIA OF THE TOWN. NEMA 311 PVC BOX 1 Pv— SCALE: 1/8" - l'-O" ROOF MODULE COUNT TILT AZIMUTH SHADING R1 35 24° 225° 92% (0 R2 16 24° 45° 94% momentum SOLAR PECONIC LN PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 325 HIGH STREET,METUCHEN,NJ 08840 (732)902-6224 MOMENTUMSOLAR.COM STRUCTURAL 0ENGINEERING FRONT OF RESIDENCE DANIEL W.DUNZIK RA LEED-AP o LICENSE NJ 085 (908)872-3664 O o 370 BURNT HILL ROAD SKILLMAN,NJ 08558 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& OO ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING TDIRECTION OF A LICENSED ARCHITECT,TO ALTERR AN AN ITEM IN ANY WAY, 00000ao t> �ERE� ARC W 00411 y1 jf�0000� a GROUND ACCESS GUTTER ) (TYP) Q 039534 y0 MSP OF NES ❑ ❑ ❑ OM AC N3R LC CUSTOMER ❑ ❑ ❑ ❑ INFORMATION R2 FIRE SETBACK STELLA SAKOWICZ ❑ ❑ ❑ ❑ (18" VENTILATION, 725 PECONIC LANE RIDGE 36" ROOF ACCESS) PECONIC NY 11958 ❑ ❑ ❑ ❑ ❑ ® (631)765-2527 JURISTICTION:SUFFOLK FIRE SETBACK UTILITY:PSE&G (18" VENTILATION, UTILITY ACCT#:9646538201 36" ROOF ACCESS) UTILITY METER#:20812439 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ PV SYSTEM ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ INFORMATION SYSTEM SIZE(DC):14.28 KW +I ❑ ❑ ❑ ❑ ❑ ❑ ❑ 51 MODULES: RECOM RCM-280-6MB GUTTER❑ 51 INVERTERS: ENPHASE IQ6-60-2-US GROUND ACCESS (TYP) R1 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ PR03ECT INFORMATION SOLAR INSTALLER NOTES: INITIAL DATE:7/17/2017 DESIGNER:MA NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED REV: DATE: DESIGNER: REV: DATE: DESIGNER: PANEL LAYOUT PV-2 ROOF FRAMING ACTUAL SPAN SHEATHING COLLAR TIES KNEE WALL SHINGLE TYPE LAYERS R1 2"X 611 RAFTER 16"OC 131-511 TONGUE AND GROOVE N/A N/A ASPHALT 1 R2 2 X6 RAFTER I6 OC 13-5 TONGUE AND GROOVE N/A N/A ASPHALT 1 momentum R1 - ARRAY 1 LAYOUT DETAIL SOLAR SCALE: 3/16" = 1'-0" "48'-7 TILT: 24PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 325 HIGH STREET,METUCHEN,NJ 08840 AZIMUTH: 225° MOM(732) 24 ENTUMSOLASOLAR.COM SHADING: 92% , 1„ STRUCTURAL 1-11Z ENGINEERING DANIEL W.DUNZIK RA LEED-AP ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ LICENSE#039534 (908)872--3664 370 BURNT HILL ROAD SKILLMAN,NJ 08558 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. 13'-2Z" ❑ ❑ ❑ 0 5'-5" ❑ ❑ ❑ ❑ ❑ \�,��RED gRcy/ C� �\V-L w DVN 4) ` ��� El El El El El El El El El 0'-6" 5' 9534 X39534 II 0'-6" OF NES SOLAR INSTALLER NOTES: NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED CUSTOMER R2 - ARRAY 2 LAYOUT DETAIL INFORMATION STELLA SAKOWICZ SCALE: 3/16" = V-01' 01 725 PECONIC LANE TILT: 24* 27-0PECONIC NY 11958 AZIMUTH: 45* 4 (631)765-2527 SHADING: 94% 1'-6" JURISTICTION:SUFFOLK UTILITY: PSE&G UTILITY ACCT#:9646538201 ❑ ❑ ❑ ❑ ❑ UTILITY METER#:20812439 10 1 PV SYSTEM 8'-11" ❑ ❑ ❑ ❑ INFORMATION SYSTEM SIZE(DC):14.28 KW 13'-21" 51 MODULES: RECOM RCM-280-6MB 2 51 INVERTERS: ENPHASE IQ6-60-2-US ❑ ❑ ❑ ❑ ❑ ❑ ❑ PROJECT INFORMATION INITIAL DATE:7/17/2017 DESIGNER:MA REV: DATE: DESIGNER: REV: DATE: DESIGNER: LAYOUT DETAIL SOLAR INSTALLER NOTES: 0'-6"j" NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED PV-3 51 RECOM RCM-280-6MB 280W MODULES PAIRED WITH 51 ENPHASE IQ6-60-2-US MICRO-INVERTERS momentum SOLAR BRANCH CIRCUIT A NEMA 3R BOX S �K s EXISITING SQUARED 100A PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 16 MICRO-INVERTER BRANCH CIRCUITS BRANCH CIRCUIT MAIN SERVICE PANEL 240 V 15 MICRO-INVERTERS 125 AMP 325 HIGH S7R32)'902 6224"'"'ossaa BRANCH CIRCUIT Cmm LOAD CENTER MAIN BREAKER: 100A MOMENTUMSOLAR.COM 10 MICRO-INVERTERS + - + - + - INE SIDE STRUCTURAL BRANCH CIRCUIT D 10 MICRO-INVERTERS HOT TAP ENGINEERING _ _ DANIEL W.DUNZIK RA LEED-AP LICENSE S 039534 ■ ■ ■ `�^ 3 0 BURN HIL SQUARE-D 125A 370 BURNT HILL ROAD 100A SKILLMAN,NJ 08558 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND S 3A FUSIBLE AC UTILITY AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE DISCONNECT METER VIOLATIONCOMPLIANCE.WARNING THAT IT IS A W FOR ANY PERSON,UNLESS ACTING NDRTHE DRECTIO OFA LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. GN 70A ��� ELECTRICIAN ROOF 15A BREAKER(ENVOY) ED JUNCTION 20A BREAKER(A) 1 BOX 2A-D 20A BREAKER(B) 3 70A FUSES R TERMINATION CAP 20A BREAKER(C) 4 FGROUND INSTALLED ON 20A BREAKER(D) GRID �RED ARC'Si END OF CABLE oPa\��.w f- C� ELECTRICAL NOTES: 4. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE ; LARGEST BRANCH CIRCUIT IN SYSTEM.OTHER BRANCH CIRCUITS � ^ nn �� 1.ALL CALCULATIONS FOR VOC,VMAX, IMP AND ISC HAVE BEEN WILL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN. CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON "9 03qr,A4 ASHRAE 2%HIGH AND EXTREME MINIMUM TEMPERATURE COEFICIENTS. 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2014 ARTICLE 310 '014%= 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 INFO V paragraph C). THE GROUND IS CARRIED AWAY FROM THE GROUNDING LUG 6.ALL EQUIPMENT INSTALLED IS RATED AT 90°C STELLA SAKOWICZ USING #6 BARE COPPER WIRE. 7. INVERTER NOC(NOMINAL OPEN CURRENT)OBTAINED FROM 725 PECONIC LANE 3. THIS SYSTEM COMPLIES WITH NEC 2014 EQUIPMENT DATASHEET PECONIC NY 11958 (631)765-2527 URISTICTION:SUFFOLK TILITY:PSE&G TILITY ACCT#:9646538201 TILITY METER#:20812439 PV SYSTEM INFORMATION SYSTEM SIZE(DC): 14.28 KW 51 MODULES: RECOM RCM-280-6MB Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire 51 INVERTERS:ENPHASE IQ6-60-2-US Wire Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC(A) Correction Current(A) Size Type 1 Open Air 4 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 16 0.96 1.25 19.20 12 AWG Trunk Cable 2A 1" PVC 3 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 16 0.96 1.25 19.20 08 AWG THWN-2 PROIECTINFORMATION 2B 1" PVC 3 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 15 0.96 1.25 18.00 08 AWG THWN-2 INITIAL DATE:7/17/2017 DESIGNER:MA REV: DATE: DESIGNER: 2C 1" PVC 3 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 10 0.96 1.25 12.00 08 AWG THWN-2 REV: DATE: DESIGNER: 2D 1" PVC 3 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 10 0.96 1.25 12.00 08 AWG THWN-2 ELECTRICAL 3 1" PVC 3 06 AWG THWN-2 90°C 75 0.96 1 72.00 51 0.96 1.25 61.20 08 AWG THWN-2 4 1" PVC 3 06 AWG THWN-2 90°C 75 0.96 1 72.00 51 0.96 1.25 61.20 08 AWG THWN-2 PV-4 TAG ' LABEL QUANTITY LOCATION NOTE EXAMPLES 1 AT EVERY SEPARATION BY momentum QA 12 DC CONDUITS ENCLOSURES/WALLS/ SOLAR PARTITIONS/CEILINGS/FLOORS P 0 O OL AI ROUVE P190 t9RG OR NO MORE THAN 10' PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR POWFRISOURCE 325 HIGH STREET,METUCHEN,NJ 08840 (732)902-6224 MOMENTUMSOLAR.COM v STRUCTURAL ENGINEERING UIPP=D H 1 AT ANY JUNCTION BOX OR DC c DANIEL W.DUNZIK RA LEED-AP © ID DOW 1 COMBINER BOX COMBINER IF USED f' 908)LICENSE8 #039534 P p p OL A p p p- O 370 BURNT HILL ROAD <<! SKILLMAN,NJ 08558 -- - ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND 'j - • AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY I BRED ARCy '• \�� �E�W DVN © E S Op D1 JUNCTION BOX 1 AT ANY JUNCTION BOX OR DC i �� , -,N �C� L-DM O O p RM L COMBINER IF USED m�Ie O SDEZAW99 E 0 -ED N T19 01M rOS Ip I •, /i •2��-9 03953b, OF NES O O OL C DSO• C CUSTOMER IM C 1 OF EACH AT FUSED AC �' , ��` OPE N CU 45 A DISCONNECT © INFORMATION O EL p p L OCK D DO NO ff @LUM S 1 AC DISCONNECT COMPLETE VOLTAGE AND STELLA SAKOWICZ O p O p 6 ER ON OT L D CURRENT VALUES ON D SIDE BE J - Q -@ DISCONNECT LABEL 725 PECONIC LANE O PECONIC NY 11958 I O - POSITIO (631)765-2527 JURISTICTION:SUFFOLK UTILITY:PSE&G UTILITY ACCT#:9646538201 O UTILITY METER#:20812439 - � F u D A ;a __ _ PV SYSTEM O D PO - SO p 1 MAIN DISCONNECT 1 OF EACH AT BUILDING MAIN ! -N - — A INFORMATION S p0 DSO p god O OUO IC PANEL DISCONNECT PANEL T -'§ SYSTEM SIZE(DC): 14.28 KW - 51 MODULES:RECOM RCM-280-6MB I' �. ' 51 INVERTERS: ENPHASE IQ6-60-2-US o a i fna.ca���u��ze; it racyn�w PR03ECT INFORMATION O - INITIAL DATE:7/17/2017 DESIGNER:MA O 1 UTILITY METER 1 AT UTILITY METER D O O pE REV: DATE: DESIGNER: �O D O p 5 P 0 0 OLTA C REV: DATE: DESIGNER: EQUIPMENT LABELS PV-5 The new EcoX is an innovative, rail-less racking system, proven to organize the installation = = process. The flexible design 1. offers a c lean aesthetic, _ -=� '-_- _ •a simplified logistics,and delivers a higher quality installationat a lower cost per watt. Aesthetic Design Cable Management WO A wide range oFadjustment makes it easy to install a Whether installing with Microinverters, Power ati straight, level system Components are designed to Optimizers, or String Inverters, EcoX provides wire blend into the array, and the aesthetic skirt creates management provisions to both prep the modules, and a Finished look Alternatively, a skirt Free option is to route homerun or trunk cables throughout the array available to provide a more traditional look __ .� ON 40f` -`> J�w .r-J� __�_ ati;1f IF L�.- _ i � T_ �i y, ,_✓:--,��'/,�.�.`.7f-'IF�Xf _�Jm - --. � Layout ~ rte - �_ r_, >E g .�a> _. — = 1= .fi �:� - - 4 � -. rr�`�'�,.`._- fir`,;, �''.�=-�-c=:==-^' .-�..<--_-- ":.. -. ✓:lrr - � �` -�. - , ,�� ,} ���.."` ,��� �-{;>�`'=�'.,;.�.'�ice':" �•��9' `- �__. .. '� "�''_-�r` �°y�Y �Y ����'• `�°�� ,��� - � � Flexible System Design Single Point Grounding The EcoX Estimator is a powerful racking system EcoX and approved modules create a continuously r� �� � _..` �.-"; design tool The user inputs all site conditions and bonded system The Installer can connect a Finished 4� , � �� �-, can layout multiple rooFsurFaces The EcoX Estimator array to ground with a single bonding lug. outputs a site speaFic design package with engineering = _ �, ,��1�� ;���,_„�,� sP�.�;,�``"'���f�•s specs and bill oFinaterlals --I A /_'../. "i 5 '..t?y-.'..,..,': �,._ - ren ei`:•`+716.:x,.'. c?'7 �*P.e'.ti•s s4a`;i• �,,`�ti..�.,;��- �i��,,v<F;-��xf�b 4���„t_'-�� Technical Specifications Racking components Alummum,'stainless hardware, dark. Fast. i m p le. Supported. Materials ° bronze anodized upper surface, mill Finish lower surFaces Flashings;Aluminum, black powder coated"finish Modules drop in From above Universal components mount to The Ecolibrium Field support team ` and there is never a need to standard Framed modules. With offers on-site installation training Grounding/Bonding Validation UL27O3 - see installation manual For specific module approvals reach over or walk on modules. a single socket size and a wide and ongoing technical support. Fire Resistance Validation UL27O3 - Class A,Type 1 and Type 2 modules Pre-assembled components range oFadjustment, it is quick And From project planning to and quick connections make and easy to install any array logistics to installation, we are Mechanical Load Validation UL27O3 - see installation manual For specific module approvals EcoX easy to install. with a clean, Finished look. dedicated to customer service. - , Flashing Validation ICC-ES AC286/UL441 Rain Test For RooF Flashing 1"vertical range, 3 5" North/South range, Adiustability connect anywhere in East/West direction Warranty 15 years p 0 Eeolibriiurnsolar sales(7ecolibnumsolarcom US 740-249-1877 wwwecolibriumsolarcom Ecolibr�iumScQar sales(Jecolibrwmsolarcom US 740-249-1877 www ecolibnumsolarcom ® Data Sheet Enphase Microinverters Enphase IQ 6 and IQ 6+ Microinverters INPUT DATA(DC) IQ6-60-2-US AND IQ6-60-5-US IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US Commonly used module pairings' 195 W-330 W+ 235W-400W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules The high-powered smart grid-ready Maximum input DC voltage 48 V: 62 V Enphase Enphase IQ 6 Micro- and Enphase IQ 6+ Micro Peak r tracking voltage 27V-37V 27V-45V Operattinging range 16V-48V 16 V-62 V IQ6 a n d IQ 6+ dramatically simplify the installation process while Min/Max start voltage 22V/4'8V 22 V/62 V achieving the highest efficiency for module-level Max DC short circuit current(module Isc) 15A 15A Microinverters power electronics. Overvoltage class DC port II II DC port backfeed under single fault 0 A 0 A Part of the Enphase IQ System,the IQ 6 and IQ PV array configuration 1 x 1 ungrounded array,No additional DC side protection required; AC side protection requires max 20A per branch circuit 6+ Micro integrate seamlessly with the Enphase OUTPUT DATA(AC) IQ6-60-2-US AND IQ6-60-5-US IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US IQ Envoy'', Enphase Q Aggregator TM Enphase IQ Peak output power 240 VA 290 VA BatteryTM,and the Enphase Enlighten'"' monitoring Maximum continuous output power 230 VA 280 VA and analysis software Nominal voltage/range2 240V/211-264 V 208 VP /183-229 V 240 V/211-264 V 208 V(1 0)/183-229 V --• - - - - - - - - - - Nominal output current 0 96 A 111 A 1.17 A 1 35 A The IQ 6 and IQ 6+ Micro extend the reliability Nominal frequency 60 Hz 60 Hz standards set forth by previous generations and Extended frequency range 47-68 Hz 47-68 Hz Power factor at rated power 1 0 10 undergo Over a million hours of power-on testing. Maximum units per 20 A branch circuit 16(240 VAC) 13(240 VAC) Enabling Enphase to provide an industry-leading 14(single-phase 208 VAC) 11 (single-phase 208 VAC) warranty of up to 25 years. Overvoltage class AC port III III AC port backfeed under single fault OA OA Power factor(adjustable) 0 7 leading .0 7 lagging' 0.7 leading .0.7 lagging . EFFICIENCY @240 V @208 V(10) @240 V @208 V(10) Easy to Install CEC weighted,efficiency 97.0% 965% 97.0% 965%, • Lightweight and simple MECHANICAL DATA Ambient temperature range -40°C to+65°C Faster installation with improved two wire Relative humidity range 4%to 100%(condensing) cabling Connector type MC4 or Amphenol H4 UTX 6 °• Built-in rapid shutdown compliant(NEC 2014) - - - - - - - - Dimensions(WXHXD) 219 mm x 191 mm x 379 mm(without bracket) A Weight 1 5 kg(3 3 lbs) ' Productive and Reliable Cooling Natural convection-No fans f Approved for wet locations Yes Optimized for high powered 60-cell and 72- Pollution degree PD3 v' cell*modules Environmental category/UV exposure rating Outdoor-NEMA 250,type 6(IP67) �.; More than a million hours of testing FEATURES • Class II double-insulated enclosure Communication Power line Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Smart Grid Ready Compliance UL 62109-1,UL1741'/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22 2 NO.1071-01 Complies with fixed power factor,voltage and This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and frequency ride-through requirements NEC-2017 section 69012 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC Remotely updates to respond to changing ; and DC conductors,when installed according manufacturer's instructions_ grid requirements } 1 No enforced DC/AC ratio See the compatibility calculator at enphase.com/en-us/support/module-compatibility Configurable for varying grid profiles 2 Nominal voltage range can be extended beyond nominal if required by the utility UL *The IQ 6+Micro is required to support 72-cell modules To learn more about Enphase offerings,visit enphase.com ® A 1 LJ /! c`c ©2017 Enphase Energy All rights reserved All trademarks or brands used are the property of Enphase Energy,Inc EAI PHASE,H /�S E, To learn more about Enphase offerings,visit enphase.com N V H/"'1.71_ 2017-05-01 1 v f Y I�.d i RECC3M REcom MONO MONO 250,260,270 280 RCM-xxx-6MB (xxx=250-280) 9 Rated Power 25OW 260W 270W 280W —I°°Aw r s � 7 —wmnm Power Tolerance 0%/+5W 0%/+5W 0%/+5W 0%/+5W 6 Max.Power Voltage 31-30V 31.70V 32.12V 3250V s s - " (Vmp) 34 J ,F Max Power Current[imp)- 8 09A 832A 8 45A 8 67A 3 z" Open Circuit Voltage(Voc). 37 92V 38.52V 38 76V 39 20V 1 0 Short Circuit Current(Isc) 8 51A 8 66A 8 78A 8 99A o s 10 15 20 zs 313 ss ao Voltage M Pmax(NOCT): 200.8W 208 8W 216.6W 223.9W The module relative power loss at low light irradiance of 200W/m'is less than 3% Module Efficiency 15.4% 16.0% 16.6% 17,7% '' 1 F° + Max.Series Fuse. 15A 15A 15A 15A Pmax Temperature Coefficient -0.39%/°C ,q Voc Temperature Coefficient -0.32%/°C --;, Max.System Voltage 1000V DC(IEC)!1000V DC(UL) _ �___- �, ;,�,; _ Isc Temperature Coefficient +0,05%/°C a• '_ :' z' ;i - 91:, Tested at Standard Test Conditions Measurement tolerances ±3Y ° •_, ;, k Operating Temperature -40-+85'C t~ „ ':` l� :``,�',-�� •R - Nominal Operating Cell Temperature(NOCT) 45±2°C Da' D • P A MOP- f 4R Dimensions 1640mm x 992mm x 35mm Container 20'GP 40'HC Frame Anodized aluminum Pieces per Pallet 29 or 30 29 or 30 Weight 19 kgs Pallets per Container 12 28 1 Front Glass 3 2 mm AR low iron tempered glass Pieces per Container 348 or 360 812 or 840 Output Cables TUV(2Pfg1169 2007),UL 4703 UL44 4 0 mm2 (0.006 m2),symmetrical lengths(-)1000mm A A s ' and(+)1000 mm,MC4 type connectors Standard tests UL1703,IEC 61215.IEC 61730 Quality tests ISO 9001 2008.ISO 14001 2004.ISO]7025 2005 8 A Certifications Class C Fire Rating,conformity to CE,PV CYCLE, I Salt Mist and Ammonia Corrosion l1640mm Extreme wind and Module certified to withstand extreme wind tE snow loads testing (2400 Pascal)and snow loads(5400 Pascal) M i Positive tolerance Guaranteed positive tolerance of up to 5W { Junction Box IP67 Rated,3 diodes 1000mm Warranties •10-year limited product warranty E Panther - - - •25-y eartransferableLinear power output warranty E C233- LINEAPERFORMANCE WARRANTY LlBIack s gam"""`^� Addtmnalvalue born RECO m Ms Gnearwa�n u fi°f Years 0 1 5 10 15 20 2S Specifications are subject to change without further notification -, r ,. C3 RECOM Manufactured Anti-PIDp o Proven by Independent + Guaranteed P , � Release 2076-02 JL 1 in EU Technology A Engineering Tests �._= Positive Power R[[MM1arsune+nv 4atr sywnywmitDayfar_•yl�-°ea,ralm :r LreN swan vrr,vslvnna an vranrdner,rtars eruni.,•ns-,w,m.i nerev� s Dealer: CE AN. (®) - retain-solar.com