Loading...
HomeMy WebLinkAbout40978-Z UfFO� , a�0� K�Q Town of Southold 10/24/2017 P.O.Box 1179 o - �" 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39313 Date: 10/24/2017 THIS CERTIFIES that the building ALTERATION Location of Property: 855 Sound View Rd, Orient SCTM#: 473889 Sec/Block/Lot: 15.-3-11.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/1/2016 pursuant to which Building Permit No. 40978 dated 9/9/2016 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: INTERIOR ALTERATIONS INCLUDING WINDOWS AND DOORS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Air,David&Claire of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40978 06-29-2017 PLUMBERS CERTIFICATION DATED 09-01-2017 Mat it ck Plumbing tho ' d ignature o�aan�� TOWN OF SOUTHOLD BUILDING DEPARTMENT z TOWN CLERK'S OFFICE o SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40978 Date: 9/9/2016 Permission is hereby granted to: Air, David & Claire 315 Eighth Ave #12B New York, NY 11001 To: construct interior alterations (including new windows and doors) to existing single-family dwelling as applied for. At premises located at: 855 Sound View Rd, Orient SCTM # 473889 Sec/Block/Lot# 15.-3-11.1 Pursuant to application dated 9/1/2016 and approved by the Building Inspector. To expire on 3/11/2018. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $200.00 CO -ALTERATION TO DWELLING $50.00 Total: $250.00 (fi/i I/ B ector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00, Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00, Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial $15.00 Date. �/(o New Construction: Old or Pre-existing Building: �,r� (check one) Location of Property: 6� House No. Street Hamlet Owner or Owners of Property: Suffolk County Tax Map No 1000, Section Block Lot J� I Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ S-b Appli Si ature ' rP pF SOl1��,®l Town Hall Annex Telephone(631)765-1802 54375 Main Road N Fax(631)765-9502 P.O.Box 1179 G a� roger.rich ert(Q-town.southoId.nV.us Southold,NY 11971-0959 �® lyc®UNT`1,�c� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Air Address: 855 Sound View Road City: Orient St: New York Zip: 11957 Building Permit#: 40978 Section 15 Block: 3 Lot: 11.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Doroski Electric License No: 2941-E SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor 1st Floor X Pool New Renovation X 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 22 Ceding Fixtures 12 HID Fixtures Service 3 ph Hot Water GFCI Recpt 7 Wall Fixtures 1 Smoke Detectors 4 Main Panel A/C Condenser Single Recpt Recessed Fixtures 25 CO Detectors Sub Panel A/C Blower Range Recpt 50A Fluorescent Fixture Pumps Transformer Appliances DW Dryer Recpt Emergency FixtureTime Clocks Disconnect F1 Switches 29 Twist Lock 11 Exit Fixtures TVSS El Other Equipment- 1- Combination Smoke/CO Detector, 4- 8 ft. LED Strips, 1- Range Hood, 1- Exhaust Fan, 5-ARC Fault Circuit Breakers. Notes: Inspector Signature: Date: June 29, 2017 0-Cert Electrical Compliance Form.)ls Telephone(631)763-1802 RaY f6R1}7fiR.. P.O.Bax 1179 ;' _ � (4' Southold,NY 11971.0959 Ell SEP 1 8 2011 L BUaDING DEPARTMENT ; TOWN ON SOUTHOLD (3 v N OF SOUTHOLD 19• +fie• CERTIFICATION Date: 7 J 1 Building Permit No, 4' `Z q7 ? Owner: V't 9-Ar (Please print) " Plumber: &R kkwL 1 (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead, (Plu TWS Signature) Sworn to before me this day of S �+1opX', 20 k1 CHELSEA L. CHALONE Notary Public, State of New York Registration#01 CH6287106 Qualified In Suffolk County Commission Expires Aug.5,, ►_1 l << Notary Public, U�' ��--County• OE SOUTyo� co urm, TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ELECTRICAL (ROUGH)- [ ] ELECTRICAL (FINAL) REMARKS: eCV6j� l -�z DATE � INSPECTORC �G ��pF SOUryo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECPON [ ] FOUNDATION 1ST [ ROUGH PL13G. [ FOUNDATION 2ND [ ] INSULATION [ ] FRAMIN STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTA/ENATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICA ) EMARKS: U /p 1 'ru K 5 1'' kyK I n v AJo '4 C�J av1/ DATEINSPECTOR �0��0 UlyOlo ��'YOOUNiV 0� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION - I FOUNDATION 1ST [ ] UGH PLBG. [ ] FOUNDATION 2ND [ INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) MARKS. '�� �krjYlS1/I/q�I D-wJ DATE INSPECTOR pF SOUlyolo cou TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ,[ J ELECTRICAL (FINAL) REMARKS: II DATE �' 4 1 INSPECTOR D l � OF SOUL eou TOWN OF SOUTHOLD BUILDING DEPT. 7CS-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING j4fFINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: Ch C ' 6Z U DATE D INSPECTOR ® ❑C�❑D�❑ Delfino Insulation D Co , 317 Burman Blvd,Calverton,NY 11933 1 8 2017 BUILDING DEFT. CERTIFICATE OF INSULATION TOWN OFSOIT HOLD JOB INFO: American Exteriors& Interiors DATE OF INSTALLATION: 02/02/17 855 Soundview Road Orient, NY 11952 2x10 Closed Sloped Ceilings Gable Walls TYPE INCHES R-VALUE TYPE INCHES R-VALUE ❑ OPEN CELL FOAM ❑ OPEN CELL FOAM P1 CLOSED CELL FOAM 2 R-13 Q CLOSED CELL FOAM 2 R-13 F] FIBERGLASS ❑ FIBERGLASS ❑ CELLULOSE ❑ CELLULOSE 2x10 Open & Closed Sloped Ceilings 2x4 Open Kneewalls TYPE INCHES R-VALUE TYPE INCHES R-VALUE ❑ OPEN CELL FOAM ❑ OPEN CELL FOAM ❑ CLOSED CELL FOAM ❑ CLOSED CELL FOAM Q FIBERGLASS 8.25 R-30 HD Q FIBERGLASS 6.25 R-19 CELLULOSE ❑ CELLULOSE 7 FIRE CAULKED TO CODE DATE OF INSTALATION: 02/02/17 ❑ FIRE BLOCKED TO CODE DATE OF INSTALATION: ❑ AIR SEAL SUBSTATE TO CODE DATE OF INSTALATION: 1 Tammy Mazzara certify that the residence referenced above was insulated as per signed proposal by builder/homeowner,and the installation was conducted in conformance to applicable codes and standards and regulations. AUTHORIZED SIGNATURE Na ■GSI e� .�tJGAitJ.� * �►MLJ,► 1 � ,•�+� �. t o �� � su, ��.. 1: � � •,,ISI �' � � � � u -. f1 r r ~R -I WIFA MAR IN u u TOWN OF SOUTHOLD _ BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey South oldTown.NorthFork.net PERMIT NO. Check / Septic Form N.Y.S D E.0 Trustees C 0.Application Flood Permit Examined ,20 Single& Separate Storm-Water Assessment Form � 1 Contact: /L Approved ,20 0===� ail to: � �/��Q Disapproved a/c a0 (k I` 3 Phone: Expiration 20 g1n p �MOd[ Buir D SEP ® 1 2016 PPLICATION FOR BUILDING PERMIT Date IV24,1 , 20 BUILDING DEPT. INSTRUCTIONS . OWI OF SOUTHOLD a. is application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. o c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed.within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. 1 appy r p e, if a corporation) (Mailing address of apfilicant) State whether applicant is owner, lessee, agen architect, engineer, general contractor, electrician, plumber or builder ( + Name of owner of premises `/ (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: �S __SZ79ar D House Number Street Hamlet County Tax Map No. 1000 Section 5_ _Block Lot 1 1, 1 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended_use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy4L , :CQIM�J� 4 , r 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost �,��, Fee (To be paid on filing this application) 5 If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars N I - 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. N �� 7. Dimensions of existing structures, if any: Front bCA Rear �`,1 71°W13e, th <ZZN rrl 8/,:71 ht Height h! Number of Stories t f �-( V. U,� <4'..°r­j I I k � Dimensions of same structure with alterations or additions: Front V/91", arric t -Rear) N� ` Depth NIA Height N 1A Number of Stories { A 8. Dimensions of entire new construction: Front Nf1,A Rear /-(/A °�^ �Depth'g-'-I6N1)r�� ��, c�1.t `�tai `au A vS'017 Height 1,j JA Number of Stories N /� ,)q 9. Size of lot: Front �10 5--v . 1 Rear�� / Depth �v�� -r2 0 10. Date of Purchase Name of Former Owner o a 11. Zone or use district in which premises are situated -- T) 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NOX 13. Will lot be re-graded? YES NO ,\*/Will excess fill be removed from premises? YES NO 14. Names of Owner of premises adare A;✓ Address Phone NoAU)&J2— Name of ArchitectAddress Phone No_�3/ -77 Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO V/ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES N07�1_ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO� * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF5Ufd2j ) 7&z - being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, n (S)He is theA1 (Contractor Agen , Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this DENISE A. NAVARRA ({ day of --,klOMRY Pl146C-STATE OF NEW YORK �Vo. OINA619�Puqt 5 Qualified In Suffo Notary Public n Expires Si e of pplicant Scott A. Russell 0�°SUFFQIr STO 1K1\\11WA\,,1F1E]K SUPERVISOR v I\\l[A NA\G]EI\\1[]ENT SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 o - Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT INVOLVE E ANY OF THE FOLLOWING. Yes No CHECK ALL THAT APPLY! , ❑ A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. [:10,13. Excavation or f illing involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑P C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑ D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑ E. Site preparation within the one-hundred-year f loodplain as depicted on FIRM Map of any watercourse. ❑ F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. ___ ---- ____ _____-______._,1 1 S.C.T.M. 1000 Date APPLICANT. (Property Owner,Design Profession l Agent, ontracta,Other) ( Dmtnct i NAME v Section Block Lot E FOR BUILDING DEPARTMENT USE ONLY*W * Contact tnfoimation. / f Tckphrc N—b- 1 — — — — — — — — — — — — — i Reviewed By \ Work- Date — Property Address / Location of Construction Work- � � � - — — — — — — — — — — — — — — E "73 _ , i M Approved for processing Building Permit. E J7 Stoi rn Nater Management Control Plan Not Required ��t• Stormwater Management Control Plan is Required. Toi ward to Engineering Department for Review.) SMCP-TOS MAY 2014 Town Hall AnnexifxTelephone(631)765-1802 54375 l�i� Road x ax(o"30 76595,12 P-O- Box 1179 _ oQ roger.richert(atown.soutd.ny.us Southold,NY 11971-0959 Q BUILDING DEPARTMENT TOWN OF SOUTHOLD j APPLICATION FOR ELECTRICAL INSPECTION ' REQUESTED BY: �� � 1 _ 1co rpany Name: Name: License No.: Address: Phone-No.: CRV '-7 61 Z— v -7-1 C/ 7 2 JOBSITE f NFORMAMN: ('Indicates required information) - *Narne: Z- r�1YS i IZ i *Address: *Cross Street: l *Phone No_: Permit No.: - '10 4 78' Tax-Map District: - 1000 Section: Block: Lot: _ *BRIEF DESCRIPTION OF WORK(Please Print Clearly) 0.jot 1 (Please Circle All That Apply) Is job ready for inspection: YES/ O. Rough In� Final *Do-you need a Temp Certificate: YES/ O Temp Information (lf needed] Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other I . *New Service: Re-connect- Underground Number of Meters Change of Service Overhead Additional Informafion: PAYMENT DUE WITH APPLICATION 82-Request for inspection Form �• ROBERT I. BROWN, ARCHITECT P.0 205 Bay Avenue Greenport,NY 11944 631-477-9752 (fax)631-477-0973 info@ribrownarchitect.com Transmittal Date: 4�( To:` IOwyl 4 Af 14 r r� Thank you, Robert I Brown Architect PC 1`01A�'11! OF SOUT�IOLD PROPERTY RECO • , --- 1 RD CARD m OWNER VILLAGE DIST. SUB.* LOT D-vvid.a. r FORMERINNER 1' . f - A- [ E ACR. C�O ': �' •ter -W ` TYPE OF BUILDING RES. 'f SEAS. VL. FARM COMM. •CB. MISC. Mkt. Value En LAND IMP. TOTAL DATE REMARKS o Cn Cf)W ` <011 1j L7 AGE BUILDING CONDITION NEW NORMAL BELOW ABOVE �Q, �. � �r `� J� �i�~cJa FARM Acre Value Per Value Acre Fit[abfe 1 Lo Tillable 2 LO Tillable 3 m iO Voodland wompland FRONTAGE ON WATER /1-4— N rushland .� FRONTAGE ON ROAD m louse PlotDEPTH m N ti BULKHEAD �r m Dta1 DOCK C'4 OWNER STREET' VILLAGE DISTRICT SUB. LOTO` ;7— �! CL FORT kiER OWNER N E ACREAGE 1 • � CO S W TYPE OF BUILDING • r �� S1 � C k - RES. ii SEAS. VL. FARM comm. I IND. � CB. � MISC. LO LAND IMP. 'TOTAL DATE REMARKS o 0 A F- • o a �w - 2 L & , 3 u--cJ i a .? A-- 1-3 0--o--� AGE Lf a a BUDDING C43�,Jf IO 7 0 NORMAL BE , ? ABOVE . Farm Acre Value Per cre ,Value n LO ?ili J > lL ro Tillable 2 LO 3 Til lohle- 3 -- - ------ ----;I---- Sl 7 �D9. � iP, 7112 ZLO Wcodiand - - co r1wamp[and-- ------ -- - -- - --- - N Brushland — °° Hose Plot ----- ----- --.—_-- -.- - ��'�- /d D r� �,�� Y• ! �� m i N N � s Nr - m Total - —--• .r.o �.s MEN - ■�■ !■iiiili�,■■■■■■■■■■ IN Rol ME MEN MEN MONONA ME a■■■■■■■■■■NOON M■M■■■MIMM m -a■�B�H■■ C •• Mom 1 ■ ■ mss■ ■ •• i S.C.T•M. N0. DISTRICT: 1000 SECTION: 15 BLOCK: 3 LOT(S): 11.1 LONG ISLAND SOUND-- TIE OUND-TIE LINES ALONG r r r MEAN HIGH WATER LINE r Ne zOO6$34"E SBO.33'3Z"E 80.51 - - - 66.50. 'gu'`'n'- - - - - - WOOD BULKHEAD TW 8.6 �'a I ZONE VE EL 15 �n ~ TOP OF BLUfF x X20.9 I EL 24.0 x T FIRM ZONE BOUNDARY — CQ I ZONE X ` �26.3 d' Vr = CQD L a ' .. LANDOF/F LOT 24 � ro LOT 23 GERARD H. BELLESHEIM I 9 SARA A. BELLESHEIM LEACHING C 65' POOL A C) 45' SEPTIC40' m LSJ��K d \ v 42' 22.6' WOOD is DECK EL 128.0 EL 28.8 24.7 ;f:;;';:':..;.,,.;:;.•.....,.;:;•6�.3 .; ....':'"•::`;',,:'' cn•S •'"'•' __- ­—NOTE_NOTE_-SANITARY 4C_WELL LOCATIONS-ARE -STY - — - - -- - — iv 2 C.".F •; ; - G:.;E: 'TON FRf.1005 SUI:VE" DATE. - - - GARAGE " 9.3: 'DWELLING ,:p DEC. 1974. U. o 1855 w I �':;',FFL,32.7?••:;:;...i,. i� co w EL 28.8 COVERED O 3 PORCH :•;•. . •� I O C+� `;30.2' 20.9'— EL 0.9'EL 31.5 Fri 3 I � � 35' 5' 2 It o WELL MON. ELI T_45— . EL 29.5 R=548 16' L_1 1 1. 77� MON. 41-52' �POINT OF CURVATURE EDGE OF PAVEMENT SOUND VIEW ROAD FIRM MAPS #36103CO067H & #36103CO086H THE WATER SUPPLY, WELD, DRYWELLS AND CESSPOOL LOCA7701VS SHOWN ARE FROM FIELD OBSERVA77ONS AND OR DATA OBTAINED FROM OTHERS. AREA: 25, 181 SQ.FT. or 0.58 ACRES ELEVATION DATUM; _NAVD88 ------------------ UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY'IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO 7HE 77TLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF 7HE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE. THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM 7HE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE ERECTION OF FENCES, ADD177ONAL STRUCTURES OR AND OTHER IMPROVEMENTS, EASEMENTS If AND/OR SUBSURFACE STRUC-TURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF SURVEY SURVEY OF: LOT 24 & DESCRIBED PORTION CERTIFIED TO: DAVID AIR; CLARE AIR; MAP OF: ORIENT BY THE SEA — SECTION ONE FIDELITY NATIONAL TITLE INSURANCE COMPANY; I FILED: NOVEMBER 21, 1957 No.2777 SITUATED AT- ORIENT TOWN OF: SOUTHOLD KENNETH M WOYCHUK LAND SURVEYING, PLLC SUFFOLK COUNTY, NEW YORK Professional Land Surveying and Design P.O. Box 153 Aquebogue, New York 11931 PHONE (831)298-1588 FAX (831) 298-1588 FILE # 14-186 SCALE: 1 "=30' DATE: DEC. 14 2014 ' N.Y.S. LISC. NO. 050882 maintaining the records of Robert J. Hennessy & Kenneth M. Moycbuk I CREScheck Software Version 4.6.2 INJ( Compliance Certificate Project Air Renovations Energy Code: 2010 New York Energy Conservation Location: Suffolk County, New York Construction Type. Single-family Project Type: Alteration Climate Zone: 4 (5750 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 855 Soundvlew Road Robert I. Brown Orient, NY 11957 205 Bay Avenue Greenport, NY 11944 631-477-9752 info@ribrownarchitect.com 0 Compliance. 6.6%Better Than Code Maximum UA 271 Your UA. 253 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home, Envelope Assemblies dross Area Cavity, Cont. Perimeter Floor 1:All-Wood J oist/Truss:Over Unconditioned Space 1,563 22.0 0.0 0.042 66 Wall 1:Wood Frame, 16"o.c. 1,400 15.0 0.8 0.072 83 Window 1:Wood Frame:Double Pane with Low-E 15 0.300 5 Window 1 copy 1: Wood Frame:Double Pane with Low-E 15 0.300 5 Window 3:Wood Frame-Double Pane with Low-E 14 0.300 4 Window 3 copy 1: Wood Frame:Double Pane with Low-E 14 0.300 4 Window 3 copy 2:Wood Frame:Double Pane with Low-E 14 0.300 4 Window 3 copy 3:Wood Frame:Double Pane with Low-E 14 0.300 4 Window 3 copy 4:Wood Frame:Double Pane with Low-E 14 0.300 4 Window 8:Wood Frame:Double Pane with Low-E 22 0.300 7 Window 8 copy 1:Wood Frame:Double Pane with Low-E 22 0.300 7 Window 10:Wood Frame:Double Pane with Low-E - 9 0.300 3 Window 10 copy 1:Wood Frame:Double Pane with Low-E 9 0.300 3 Window 12: Wood Frame:Double Pane with Low-E 14 0.300 4 Window 12 copy 1:Wood Frame:Double Pane with Low-E 14 0.300 4 Door 1: Glass 40 0.500 20 Door 2: Solid 20 0.540 11 Project Title: Air Renovations Report date: 08/31/16 Data filename: C:\Users\Rob\Documents\REScheck\Air.rck Pagel of 7 p. l 1 Cavity cont. Ceiling 1: Cathedral Ceiling 535 22.0 13.0 0.028 15 Ceiling 2: Flat Ceiling or Scissor Truss --- --- --- --- --- Exemption: Framing cavity filled with insulation Compliance Statement. The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in REScheck Ve io .6.2 and to comply with the mandatory requirement listed in thc- EScheck I ctio Check'St. a / 6� Ne itle Si toe Da Project Title: Air Renovations Report date: 08/31/16 Data filename: C:\Users\Rob\Documents\REScheck\Air.rck Page 2 of 7 r ` REScheck Software 0/ersion 4.6.2 Air Inspection Checklist Energy Code: 2010 New York Energy Conservation Construction Code Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section = plans Verified Field Verified # Pre-Inspection/Pian.Review. Complies? Comments/Assumptions" & Req.113 Value Value 103.2 'Construction drawings and a❑Complies ;Requirement will be met. [PR1]1 documentation sufficiently 4❑Does Not .i demonstrates energy code E a❑Not Observable compliance for the building envelope. j"°. y , ;❑Not Applicable 103.2, Construction drawings and #> <❑Complies ;Requirement will be met. 403.7 documentation sufficiently ❑Does Not ; [PR3]1 demonstrates energy code compliance for lighting and K J. ❑Not Observable ;mechanical systems.Systems ❑Not Applicable serving multiple dwelling units must demonstrate compliance ;with the commercial code. ¢ 403.6. tHeating and cooling equipment is; Heating: Heating: ;❑Complies ;Requirement will be met. [PR2]2• ;sized per ACCA Manual S based Btu/hr Btu/hr I❑Does Not Ion loads per ACCA Manual J or Cooling- Cooling: ;other approved methods. g: :E-]Not Observable Btu/hr Btu/hr ❑Not Applicable • Additional Comments/Assumptions: 11 High Impact(Tier 1) 1,2' Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Air Renovations Report date: 08/31/16 Data filename: C:\Users\Rob\Documents\REScheck\Air.rck Page 3 of 7 Section #, Foundation Inspection, Complies? Comments/Assumptions: & Reci.IL1 303.2.1 'Exposed foundation insulation ;❑Complies ;Requirement will be met. [F011]? protection. ;❑Does Not 3 ' ;❑Not Observable: ❑Not Applicable ; 407,,8,` ;Snow melt controls. ;❑Complies 'Exception: Requirement is not applicable. (f Q12]2 ;❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 . Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Air Renovations Report date: 08/31/16 Data filename: C:\Users\Rob\Documents\REScheck\Air.rck Page 4 of 7 Section Plans Verified Field Verified # Framing!Rough-in Inspection ValueValue`` Complies? CoMments/Assumptions &-Req.ID 402.4.4 Fenestration that is not site built i = y❑Complies ;Requirement will be met. [FR20]1 is listed and labeled as meeting l❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 1 'or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code bNot Applicable :limits. g 402,4.5 i]C-rated recessed lighting fixturesi g`❑Complies ;Requirement will be met. [FR16]2 ;sealed at housing/interior finish . . (❑Does Not ;and labeled to indicate&It;= 2.0 ;cfm leakage at 75 Pa. J❑Not Observable _ J❑Not Applicable 403.2.2 All joints and seams of air ducts, { = 4❑Complies ;Requirement will be met. [FR13]1 air handlers,filter boxes, and I❑Does Not building cavities used as return 3 461 E]Not Observable ducts are sealed. 6 } ; j I❑Not Applicable ; 403.2.3 Building cavities are not used as ' J❑Complies ;Requirement will be met. [FR15]3 ducts or plenums. w ❑Does Not �❑Not Observable ; 1 i❑Not Applicable 403.3 ;HVAC piping conveying fluids R- R- ;❑Complies ;Requirement will be met. [FR17]2 =above 105°F or chilled fluids '❑Does Not i ;below 55°F are insulated to R-3. 0. ;❑Not Observable , ❑Not Applicable 403.4- SCirculating service hot water R- R- ;❑Complies ;Requirement will be met. [FR18]2 =pipes are insulated to R-2. ;❑Does Not ? ;❑Not Observable ❑Not Applicable 403.5.2 Automatic or gravity dampers are, ❑Complies ;Requirement will be met. [FR19] installed on all outdoor air i w - ❑Does Not f intakes and exhausts. t p ,❑Not Observable ; J❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Air Renovations Report date: 08/31/16 Data filename: C:\Users\Rob\Documents\REScheck\Air.rck Page 5 of 7 Section. # Insulation Inspection Complies? Comments/Assumptions , &.Req.ID 303.1 ,_'All installed insulation labeled or '❑Complies Requirement will be met. [1N13]2; 3 installed R-values provided. '❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Air Renovations Report date: 08/31/16 Data filename: C:\Users\Rob\Documents\REScheck\Air.rck Page 6 of 7 � � 1 1 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Com Ales? Comments/Assumptlons & Req.il) 402.4.2, Building envelope tightness ACH 50 = ACH 50 = ❑Complies ;Requirement will be met. 402.4.2.1 verified by blower door test result ❑Does Not [F11711 of&lt;7 ACH at 50 Pa.This 401 requirement may instead be met :❑Not Observable via visual inspection, in which ❑Not Applicable case verification may need to occur during Insulation Inspection. 403.2.2 Duct tightness via post- cfm cfm '❑Complies ;Requirement will be met. [F14]1 construction with maximum ❑Does Not leakage of 8 cfm to outdoors, or 12 cfm across systems. For ❑Not Observable rough-in tests,verification may ❑Not Applicable need to occur during Framing Inspection, with maximum leakage of 6 cfm across systems and 4 cfm without air handler. 403.1.1 Programmable thermostats ❑Complies ;Requirement will be met. [F€9]2 =installed on forced air furnaces. ❑Does Not ❑Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies :Requirement will be met. [F110]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water ❑Complies ;Requirement will be met. [F111)2 :systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ' "❑Not Applicable 401.3 `Compliance certificate posted zElComplies :Requirement will be met. [F17],2 ❑Does Not , + ❑Not Observable ; ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies ;Requirement will be met. [F11813 mechanical and water heating EDoes Not ,equipment have been provided. ; .❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Air Renovations Report date: 08/31/16 Data filename: C:\Users\Rob\Documents\REScheck\Air.rck Page 7 of 7 2010 New York ■ Energy on Construction Energy Efficiency m m Certificate ■ Above-Grade Wall 15.80 Below-Grade Wall 0.00 Floor 22.00 Ceiling / Roof 35.00 Ductwork (unconditioned spaces): Window 0.30 Door 0.50 Heating System: Cooling System: Water Heater: Name: Date: Comments K(md ISSUES/ REVISIONS RESIDENTIAL GENERAL NOTES MISC. GENERAL NOTES CLIMATIC AND GEOGRAPHIC CRITERIA 1.THI5 PROJECT 15 CON5TRUCTION OF RENOVATIONS TO AN EXISTING SINGLE FAMILY RESIDENCE, CLASSIFIED AS R-3. GROUND SNOW LOAD 20 PSF (PER FIG.R301.2(5)RCNY5) �{ R I 2.THE HEIGHT OF THE EXISTING BUILDING AS DEFINED BYTHE RESIDENTIAL CODE NEW YORK STATE IS WIND SPEED 120 MPH (PER FIG.R301.2(4)RCNY5) /'S � i ED AS ��OTED SEISMIC DE51GN CATAGORY B (PER SECT.R301.2(2)KCNY5) q 12'-9' WINTER DE51GN TEMP I I°F (PER TABLE N 1 10 1.2) • DATE: ® .P.# 3.THE TYPE OF CONSTRUCTION 15 TYPE V(B)• FLOOD ZONE N/A (PER FEMA MAP) PLUMBER CERTIF/CA 4.ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2D 10 RESIDENTIAL CODE OF N.Y.5.AND MOST UNE DEPTH 3G' C" �) THE AF 4 PA WWOD FRAME CONSTRUCTION MANUAL 1995 56C HIGH WIND EDITION. WEATHERING PROBABILITY SEVERE (PER FIG.R30I.2(3)RCNY5) F E. v By: ON LEAD CONTENT BEFc,. . 5.DESIGN LOAD CALCULATION ARE BASED ON: DE51GN LOAD CALCULATIONS (UNIFORM LIVE LOADS) LIVE LOAD:AS PER TABLE R301.4,RESIDENTIAL CODE OF NEW YORK765.1180STATE. ROOMS OTHER THAN SLEEPING 40 P51 (PER TABLE 301.5 RCNY5) IRI 1 602 8 AM FY BUILDING AM DEPA T M AT TO 4 PM FOR THE CERTIFICATE OF OCCUP!^,�, DEAD LOAD:CALCULATED AS PER 8301.3 AS PER RCNY5. SLEEPING ROOMS 30 P51 (PER TABLE 301.5 RCNY5) FOLLOWING INSPECTIONS: _ SNOW LOAD:45 P51 GROUND SNOW LOAD(AS PER FIG.R301.2X5)RCNY5. ATTICS WITH LIMITED STORAGE 20 P51 (PER TABLE 301.5 RCNY5) t. FOUNDATION - T�">r0 REQUIRED SOLDER USED IN WA F:', SEISMIC DESIGN CATAGORY'C•,FOR 120 MPH 3 SECOND GUST.. ATTICS WITHOUT STORAGE 10 P51 SUPPL Y SYSTEM CANNG STAIRS 40 P51 (PER TABLE 301.5 RCNY5) s':Ora POURED CONCRETE LOCATION LIVE DEAD DELECT LIMrr2. ROUGH - FRAMING & PLUMBING EXCEED 2110 OF 1% LE/i D. 15T.FL. 40 LB, 12 L/3Go 2ND.FL.(SLEEP AREA) 30 LB. 12 1/360 3. INSULATION ATTIC(NON 5TORAGE) 20 LB. 10 V3G0 4. FINAL - CONSTRUCTION MUST ROOF 20 LB. 15 L/3G0 G,THE ARCHITECT ASSUMES NOKE5PON51BIUYFOR THE CONSITRUCTIONMEANS.METHODS, 6E COMPLETE FOR C.O. .PLUMBING ALL CONSTRUCTION SHALL MEET THE TECHNIQUES,SEQUENCES,OR PROCEDURES,OR FOR SAFETYPRECAUTION5 AND PROGRAMS IN ! EXISTING WINDOW TO EXISTING WINDOW TO REQUIREMENTS OF THE CODES OF NEW ALL PLUMBING WASTE CONNECTION WITH THE WORX, REMAIN REMAIN THERE ARE NO WARRANTIES,NOR ANY MERCHANTOILTTY Or FITNESS FOP,A SPECIFIC USE EXPRESSED YORK STATE. NOT RESPONSIBLE FOR & ATER LINES NEED 'fS71NG BEFORE CO OR IMPLIED IN THE USE OF THESE PLANS. DESIGN OR CONSTRUCTION ERRORS. VFRINGra` 7.CONTRACTOR TO VERIPI'ALL DIMEN51ON5 BEFORE STARTING CONSTRUCTION.DO NOT SCALE DRAWINGS.FOLLOW DIMENSIONS ONLY. 8.CONTRACTOR(5)SHALL FURNISH AND INSTALL ALL MATERIAL AND EQUIPMENT SHOWN,LISTED,OR DESCRIBED ON THESE DRAWINGS SUBJECT TO QUALIFICATIONS,,CONDITIONS,OR EXCEPTIONS AS NOTED.CONTRACTOR SHALL FURNISH ALL LABOR,SCAFFOLDING,AND TOOLS NECESSARY TO JOVP COMPLY WITH ALL CODES OF RETAIN STORM WATER RUNOFF COMPLETE THE WORK. NEW YORK STATE & TOWN CODES 9.ALL MATERIAL SHALL BE INSTALLED IN STRICT CONFORMANCE IWITH MANUFACTURES REQUIREMENTS UL> LSI PURSUANT TO CHAPTER 236 AND SPECIFICATIONS. I AS REQUIRED AND CONDITIONS OF OF THE TOWN CODE. 10.CONTRACTOR SHALL OBTAIN ALL REQUIRED INSPECTIONS,AP'PROVAL5 AND CERTIFICATE OF l OCCUPANCY. b�(`(� ,,.$0MOLD TOV,14 ZBA____ DEMOLITION 1,� `1 D ( v�� S0 $T &, .PLA:NNtl"t3�AAP.D 1.CONTRACTOR SHALL DEMOLISH WALL5 AND PLAOR.INDICATEDI ON DRAWING5 AND A5 NECE55ARY, EX I S(T�I N G EXISTING r 1 ,(� /� /y 2.CONTRACTOR RIS. BEDROOM BEDROOM h ' {`r` SV HOLD Y i TEES 2.CONTRACTOR SHALL DO ALL PATCHING REQUIRED DUE TO REMOVAL OF EXISTING WORK AND OR �V� r n �(� TRUSS PLACAR®IE:a F:EQIl9F:ED INSTALLATION OF NEW YORK ^ �t N1 3.ALL NEW YORK SHALL MATCH AND MEET FLUSH TO EXISTING WORK AS CLOSELY AS POSSIBLE UNLESS J(� OTHERWISE NOTED. 4. EXISTING STRUCTURE AND INTERIORS TO REMAIN SHALL BE PROTECTED AS NECESSARY DURING DEMOLITION AND CONSTRUCTION, PROVIDE 14M3OG CROWN (2) NEW 2068 DOO CEILINGS IN IXISTINIG 5. CONTRACTOR SHALL PROTECT EXISTING SERVICES TO REMAIN AND SHALL NOTIFY ALL UTILITIE5 AND MOLDING IN ALL BEDROOMS AND TO MATCH EXISTING BEDROOMS AND HALL TO Y OR AND PAINT. TELEPHONE SERVICES AND MAKE ARRANGEMENTS FOR HOOK-UP,REMOVAL,OR CAPPING OF EQUIPMENT BATHROOMS. SMOOTH, PRIME ERIOR DOOR REMAIN ,�L b OCCUPANCY AS NECESSARY. EX15TING WINDOW TO v 1 GENERAL CONSTRUCTION LAEXISTING WINDOW TO -- REMAIN p\�� USE IS UNLAWFUL . 1.PROVIDE ALL BOR,MATERIALS,TRANSPORTATION,EQUIPMENT AND SERVICES NECESSARY TO REMAIN I CUT OPENING INTO EXISTING '� ` WITHOUT CERTIFICATE COMPLETE ALL WOOD AND PLASTIC WORK REQUIRED 13Y THE DRAWINGS AS SPECIFIED HEREIN,OR CEILING B REASONABLY IMPLIED AS NECE55AKYTO COMPLETE THE WORK. I I NrKAMr_ N PATCH A5 ANCY 2.FASCIAS,SOFFITS AND EXTERIORTRJM SHALL MATCH EXISTING. 3.INTERIOR TRJMSHALL MATCH EXISTING. N�WFOLDING OF OCCUP 4.FRAMING ELEMENTS: STAIR A.ALL FRAMING LUMBER SHALL BE GRADE STAMPED DOUGLAS FIR-LARCH STRUCTURAL GRADE NO.2 T ATTIC ORBETTER I REPLACE EXISTING B.ALL ENGINEERED LUMBER SHALL BE AS INDICATED ON DRAWINGS,AND SHALL BE INSTALLED,CUT 2 'x54" J VANITY AND N VA AND DRILLED IN ACCORDANCE WITH MANUFACTURERS REQUIREMENTS AND SPECIFICATIONS. .-NEW TILE C.ALL SHEATHING TO BE APA RATED,EXPOSURE 1,THICKNESS AS INDICATED. LAVATORY 00 AND TORY ELECTRIC/1 C�: D.ALL SUB FLOORJNGTO BE APA RATED 5TURD-I-FLOOR,EXPOSURE 1,3/4'MIN.THICKNESS. FLOOR p ^� CT1��� REG TIRED E.ALL HEADERS 0-0'AND OVER SHALL BE SUPPORTED WITH DOUBLE UPRIGHTS,9'-(Y AND OVER NEW RELOCATE It f f 1 EJ 1 iL.W WITH TRIPLE UPRIGHTS.ALL HEADERS SHALL BE A MIN.OF(2)2'x8'OR AS SHOWN ON DRAWING. O WALL MOUNTED TOILET AS EXISTING WINDOW TO F.SOLID BLOCKING SHALL BE PROVIDED FOR ALL JOISTS AIND FLOOR BEAMS AS PER N.Y.5.CODE O U tu 0 TOILET SHOWN REMAIN OR AS NOTED @ 8'-0'O.C.MIN..PROVIDE 2'SPACE FOR AIR CIIPCULATION IN ROOF. p g,o U 68-1/ " 2'-10" G.PROVIDE DOUBLE FRAMING AROUND ALL OPENINGS(5TAJR5,ETC.)OR AS NOTED ON DRAWINGS. � Z = 0 uj� - 0 PROVIDE (2)AURORA CUSTOM A5512 SOL FIBERGLASS H.DRAWING SIDE DOUBLE UP FRAMING UNDER ALL POSTS AND PARALLEL PARTITIONS OR AS NOTED ON IY 0 0 N HEAD F UCET NEW SLOPED GLASS PANEL EXTERIOR DOOR 3G"x80"BY JELDWEN, EXISTING MAY 1�+, '01 G I.ALL FLUSH WOOD CONNECTIONS SHALL BE FASTENED WI1rH RATED GALVANIZED METAL EXISTING WINDOWS TO zo L�SL (RELOCATED) PAN PROVIDE NEW ALUMINUM SCREEN DOORS, IN CONNECTORS BY•SIMP50N'QR APPROVED EQUAL. B E D MO O M [STING OPEN I NGS J.NAILING SCHEDULE SHALL BE AS PER N.Y.5.BUILDING CODE AS A MINIMUM.ALL 2'xG'5TUD5 REMAIN ILL_> U (PELOCATED) APRIt_ 1=1, 2o I c SHALL RECEIVE 5 1 Od NAILS AT SILL AND PLATE.ALL EXTERIOR NAML5 SHALL BE GALVANIZED. SEE j �Q H TUB/SHOWER T ATTACHED NAILING SCHEDULE. O K PLACE EXISTING. DECEMBER 2 I , 201 5 K.PLYWOOD SHEATHING TO BE NAILED 8d NAILS @ 4'O.C.EXTERIOR EDGES AND Gd NAILS @ 12' 2 O REMOVE EXISTING O.C.INTERMEDIATE. SEE ATTACHED NAILING SCHEDULE. W W=O RICAN STANDA SHOWER L.ALL INTERIOR AND EXTERIOR FINISHES TO BE SELECTED 13Y OWNER. ~ " " lw M.ALL ROOF RAFTERS SHALL BE ATTACHED TO THE PLATE AND STUD WITH GALVANIZED HURRICANE TYPE CONNECTORS BY'51MP5ON'OR APPROVED EQUAL FOR T OBER PILE FOUNDATIONS,PROVIDE EXISTING GARAGE DOORS EXISTING GARAGE DOORS HURRICANE CUPS AT ALL PERIMETER JOISTS TO GIRDERCONNECIIIONS. THE=SE PLANS ARE AN INSTRUMENT OF SERVICE 5.ALL NEW WINDOW'•TO BE THERMAL INSULATED LOW-E GLASS, WITH ARGON GAS,IMPACT RE515TAW AS NEW STAIRS IN TO REMAIN TO REMAIN AND ARE THE PROPERTY OF THE ARCHITECT, G.LfRf OAD PATHS ARE INDICATED BY SECTION DRAWINGS. EXISTING OPENING I U RED. INFRINGEMENTS WILL BE PROSECUTED 7.CONNECTIONS SHALL BE BUILT IN ACCORDANCE WITH AN51/AF/4 PA WCFM-1995.(5EE NAILING WITH PINE RISERS 5CHEDULE) AND OAK TREAD (2)NEW ANDERSON 2014 ALL RIGHTS RESERVED 8.FLASHING AT ALL WINDOW AND DOOR OPENINGS SHALL BE EPIDM OR APPROVED RUBBERIZED 400 SERIES MEMBRANE. EXISTING CEILING TO MATCH LIVING WOH 210210 9.FLASHING AT ROOF CONNECTIONS,VALLEYS,CHIMNEYS AND iCRICKETS SHALL BE ALUMINUM. ( ) 1-314"X I I-1/4" TO REMAIN ROOM 2 I O.STEP FLASHING SHALL BE USED AT ALL INTERSECTIONS OF SLOPED AND VERTICAL SURFACES,EXCEPT - - -- MICROL AM LVL _- -- - STEP FLASHING AND COUNTER-AND CAP-FLASHING SHALL BE USED AT INTERSECTION OF ROOF AND EXISTING WINDOW TO - -- -- -- - -- -- - - CHIMNEY,AND ROOF AND WALL5. REMAIN N CATHEDRAL I _ EXISTING WINDOW TO 1 1.INSULATION SHALL BE BATT INSULATION OF THICKNESS INDICATED ON THE DRAWINGS AND SHALL BE CE NG REMOVE ALL EXISTING BASE 18' 3G' c� I REMAIN 2-1/2 Ib. DENSITY FIBER-GLA55 BATTS CONFORMING TO THE SPECIFICATIONS FOR PRE-FORMED MOLDING THROUGHOUT HOUSE. BR OM REFR FIBROUS GLA55 INSULATION.NAAMM STANDARD 51, 1 L-70. BUILT-I 12.NEW INTERIOR DOORS SHALL MATCH EXISTING. BOOK A5E REPLACE WITH 28320 MDF BASE. 11-3" CL SET N SK I Robert 1 . Brown 13. NEW HARDWARE SHALL MATCH EXISTING. SMOOTH PRIME AND PAINT. 14.GYPSUM BOARD SHALL BE EASED EDGE TYPE,CONFORMING TO A5TM C3G,AND SHALL BE I Architect, P.C. '5MEEMOCK 5W'BY U.S.GYPSUM C.O.OR APPROVED EQUAL GYPSUM WALLBOARD THICKNESS SHALL BE 15.ALL NEW AND REPAIRED GYP.BOARD SHALL BE TAPED AND 5PACKLED THREE(3)COATS.ALL EXTERIOR 205 Ba Ave. Greenport NY CORNERS SHALL HAVE METAL CORNER BEADS. EXISTING LIVING MOO M 42' ALL �t I Y p FINISHES REMOVE G r I EXISTING STAIR AND A info@ribrownarChiteCt.com EXISTING FIREPLACE GAURDRAIL 1. CERAMIC TILE FLOOR SHALL BE SELECTED BY OWNERS AND IN'STALlED WITH THIN EXISTING ( A3 G31 -477-9752 SET ADHESIVE. TO REMAIN LEVEL EXISTING FLOOR STAIRS EX15T1 NG 2.EXTERIOR PAINT SHALL BE LATEXACRYLIC BY BENJAMIN MOORS OR APPROVED BRICK TO BE STAINED " EQUAL,APPLIED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND L= LINK PROVIDE GARAGE TO MATCH NEW HOOD RECOMMENDATIONS. COLOR TO BE SELECTED. i 3.EXISTING INTERIOR WALLS AND CEILINGS IN ROOMS AFFECTED BY THE WORK EXTERIOR FINISH 3'x 7' VENT WITH STOVE SHALL BE CLEANED AND REPAINTED. NEW WALLS AND CEILINGS SHALL BE SEALED G MANTEL, NEW HANDRAIL TO ISLAND WITH IT IS A VIOLATION OF THE LAW FOR ANY PERSON, AND PAINTED.PAINTING SHALL BE TWO (2)COAT5 BREMOTE ENJAMIN MOORE AQUA PEARL LATEX PAINTED,COLOR TO BE SELECTED. PATCH BRICK REMOVE EXISTING NECESSARY, MOTOR O HOOD. UNLESS ACTING UNDER THE DIRECTION OF A 4. INTERIOR TRIM SHALL BE SANDED SMOOTH,PRIMED,AND FINISHED WITH TWO(2) ENCL05E STAIRWAY 4, 0., PROVIDE LICENSED ARCHITECT, TO ALTER ANY ITEM ONGOATS BENJAMIN MOORS LATEX ACRnIc SEMI�LosS PAINT. PROVIDE NEW MANTEL TO BE I I NEW GAS THIS DRAWING IN ANYWAY, ANY AUTHORIZED SELECTED. LINE ALTERATION MUST BE NOTED, SEALED, AND HVAC 1= � 3 I DESCRIBED IN ACCORDANCE WITH THE LAW. 1.PROVIDE ALL LABOR,MATERIALS,TRANSPORTATION,EQUIPMENT AND SERVICES C REMOVE CEILING IN THE AREA CREATING i NECE55AKYTO PROVIDE A HVAC 5Y5TEM TO HEAT AND COOL TIME LIVING SPACES AS REQUIRED 13Y THE DRAWINGS AND SPECIFICATIONS,OR REASONABLY IMPLIED AS A3 CATHEDRAL CEILING w/� GYP. BD PATCH EXISTING FLOOR AS NECESSARY NECESSARY TO COMPLETE TO WORK 2.REMOVE ALL BASEBOARD HEATING UNITS WHERE WALLS ARE REMOVED. EXISTING WINDOW TO 3.WITH EXISTING BOILER AND HOT WATER HEATER,PROVIDE 3 HEATING ZONES EXISTING WINDOW TO PROVIDE NEW 3"x8"DRESSED FIR REFINISH WOOD FLOORS WITH 4 COATS I I REMAIN (BEDROOM AREA,GREAT ROOM,BASEMENT)AND 2 COOLING MINES(BEDROOM CUT IN NEW BEAM REMAIN POLYURETHANE. AREA,GREAT ROOM), COLLAR TIES @ 48"O.C.AS SHOWN ABOVE TO SUPPORT �;. 4,PROVIDE DUCTWORK,AND CONTROLS AS NECESSARY TO COMPLETE THE WORK BUILT-N 2'-3" C ROOF. 2x I Owl(2) BOOKCASE 4'STEEL PLATES. �/; �, -✓ EXISTING DOOR TO NEW CATHEDRAL EXISTING CEILING REMAIN 1.PROVIDEALLLABOR,MATERIAL5,TRANSPORTATION, EQ(nPMENT,AND SERVICES CEILING I TO REMAIN NECESSARY TO COMPLETE ALL NEW PLUMBING WORA REQUIRED BYTHE DRAWINGS AND SPECIFICATIONS,OR REASONABLY IMPLIED AS NECE55ARYTO COMPLETE THE WORK. 2. CONFORM TO THE NEW YORK STATE ENVIRONMENTAL CONSERVATION LAW WITH FLAT CEILING FLAT CEILING REGARDS TO WATER SAVING AND CONSERVATION. ALL FIXTURES SHALL BE ON THE R�AIOVE EXISTING DOOR AND WINDOW, APPROVED 115T OF CERTIFIED WATER SAVING PLUMBING FIXTURES'A5 PUBLISHED BY THE NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION. REFRAME AND REPLACE W/ANDERSON 5TORMWATCH 3. ALL WORK ON THE PLUMBING SYSTEM SHALL BE PERFORMED BY OR UNDER THE /7FWGDGOG8L5LIDlNG PATIO DOOR CLIENT/OWNER SUPERVISION OF A PROPERLY LICENSED MASTER PLUMBER. UPON COMPLETION,THE EXISTING WINDOWS EXISTING WINDOWS PATCH AS NEC. INCLUDING BRICK FACE PLUMBER SHALL PROVIDE A SOLDER CERTIFICATE AS REQUIRED BY THE TOWN OF 4.THE CLD. TO REMAIN TO REMAIN AIR MES I D E N C E 4.THE CONTRACTOR SHALL OBTAIN,SUBMIT,AND PAY FOR ALL PERMITS, CERTIFICATIONS,LICENSES AND INSPECTIONS ASS REQUIRED BY LOCAL,5TAM,AND FEDERAL AUTHORITIES,AND ANY OTHER APPLICABLE JURISDICTION. t 855 ELECTRICAL /�((� c h ORIENT, NY VIEW ROAD 1,FURNISH ALL LABOR,MATERJAL5,EQUIPMENT.PLANT.TOOL5,AND SERVICES C� c V L I� � n `4- NECE55AKYAND REQUIRED FOR PROPER AND COMPLETE IN5TALLATION OF ALL NEN NOTE: ENTIRE INTERIOR OF NOTE: REPLACE ALL LSC OVI ELECTRICAL SYSTEMS AND RELATED WORK INCLUDING,BUT NOT LIMITED TO: t X 15T1 N G DEC CONNECTIONS TO PREVIOUSLY INSTALLED ELECTRICAL SYSTEMS, WIRING,LIGHTING, HOU-5E TO BE PAINTED WI N DOW AN D DOOR TRI M SERVICES.FEEDERS.DISTRIBUTION AND PROTECTION EQUIPMENT.CONNECTIONS TO n II REP E EXISTING WOO DECKING WITH APPLIANCES, GROUNDING,AND ALL INCLUDING ALL CONNECTIONS AND DEVICES COLORS TO BE SELECTED. WITH I X 4 51 N GLE BEAD TREX'EN Ce I"X-"COMPOSITE 6 WITHIN THE SCOPE OF THE WORK AS SHOWN ON THE APPLICABLE DRAWINGS AND AND 5PCIFICATION5 AND AS NORMALLY SPECIFIED IN TH15 TYPE OF PROJECT AND FILL SPACKLE AND REPAIR CA51 N G (WOOD) TO BE GROOVED E J6CKING(WITH HIDDEN PROJECT TITLE INCLUDING CONNECTION5 TO PREVIOUSLY IN5TALLED TRANSFORI;NERS AND FASTENERS, AND-MATCHING TRIM. ELECTRICAL DISTRIBUTION 5YSTEM5. A5 NECE55ARY. PAINTED. COLOR TO,K SELE D. 2.ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 201 O ELECTRICAL CODE OF NEW YORK STATE,THE NATIONAL ELECTRICAL CODE,NEPA NO,70-1984 (NEC), LOCAL UTILITY STANDARDS,OCCUPATIONAL SAFETY AND HEALTH CAT(OSHA), RENOVATIONS THE NATIONAL ELECTRICAL MANUFACTURERS'ASSOCIATION(NEMA)AND ANY OTHER APPLICABLE CODES. IN THE EVENT OF CONFLICT,THE MORE 5TRIINGENT ^rn I D REQUIREMENTS WILL APPLY. [k aY 3.ALL PRODUCTS USED FOR ELECTRICAL WORK SHALL BEAR THE UNDERWRITERS7] NEW 5TAINLE55 STEEL CABLE LABORATORIES,INC.LABEL AND BE 5UITABLf FOR THE ENVIRONA+IENT IN WHICH THEY WITH MAHOGANY POSTS RAILING WILLBE INSTALLED. P RO P05 E D FLOOR PLAN 4.ALL WORK ON THE ELECTRICAL SYSTEM SHALL BE PERFORMED BY OR UNDER THE DRAWING TITLE SUP SUPERVISION OF A PROPERLY LICENSED MASTER ELECTRICIAN. 5.THE CONTRACTOR SHALL OBTAIN,SUBMIT,AND PAY FOR ALL P'EKMfTS,LICENSES AND INSPECTIONS AS REQUIRED 13Y THE LOCAL,STATE,AND FEDIERAL AUTHORITIES, EX15TI NG ACCEPT A5 NOTED FI RST FLOOR PLAN AND ANY OTHER APPLICABLE JURISDICTION. G.CARBON MONOXIDE DETECTORS IN CONFORMANCE WITH APPLICABLE CODESrl 83 SHALL BE CONNECTED TO THE LIGHTING CIRCUITS WITH NO INTERVENING WALL 114 = 1 I A/+ SWITCH. UNE CORD-CONNECTED,DIRECT PLUG-IN,AND BATTERY'POWERED ALARMS ✓� ARE NOT ACCEPTABLE. ALARMS SHALL BE INSTALLED ON EACH LEVEL ON WHICH SLEEPING QUARTERS ARE LOCATED. 7.SMOKE DETECTORS IN CONFORMANCE WITH THE ELECTRICAL CODE OF NEW YORK STATE AND THE RESIDENTIAL CODE OF NEW YORK STATE,THE NFP•A NATIONAL FIRE c ALARM CODE NO.72-1993 SHALL BFE PROVIDED OUTSIDE EACH SEPARATE SLEEPING r'�iia-.- AREA,IN EACH 5PLEfPING AREA,AND ON EACH FLOOR LEVEL. At G Vl_k', kllr�e N10\ ISSUES/ REVISIONS REPLACE EXISTING WOODEN SHINGLES WITH BRICK TO MATCH EXISTING BRICK SIDING ALL EXTERIOR BRICK TO BE WHITE WASHED I ---- — ALL EXTERIOR BRICK TO BE WHITE WASHED DREPLACED O O EXISTING GARAGE DOORS WITH =REMOVE ALL EXISTING SHUTTERS _ NEW GARAGE DOORS TO BE CLOPAY — --------- -- - --- - - --- - - - --- - - - - -- - - - a = -� COACHMAN SERIES WITH 2"INTELLICORE INSULATION, DESIGN 12 WITH REC I I (2) NEW ANDERSON - - INSULATED GLASS 400 SERIES WDH 210210 T ALL EXTERIOR BRICK TO BE LIME WASHED CONTRACTOR.TO PROVIDE SAMPLE AREAS TO DETERMINE FINAL COLOR PRO POSED FRONT ELEVATION PRIOR T PAINTING, CONTRACTOR SHALL INSPECT AND NDIRIREPOINT BRICK AS NECESSARY EXISTING ACCEPT A5 NOTED 1/4" = 1' MAY 19, 201 G APRIL 14, 201 G DrGEM[lrsK 2 1, 2015 Tt!}_ !° ►l \N` ARF AN !N'TRI,Tt.1INT O�t,�l<�;,1� ANL'ARf-I11F_MKOt L�,IY Or 11=11_AF:CFIITECfi.. IW 0'3(-til:1`ur�,\,,, L u,,.— '` 1'TED 2014 ALL RIGHTS F:1-5I]RV[D Robert I . Brown Architect, P.C. 205 Bay Ave. Greenport NY info@ribrownarchitect.com G31 -477-9752 IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT, TO ALTER ANY ITEM ON THIS DRAWING IN ANYWAY. ANY AUTHORIZED ALTERATION MUST BE NOTED, SEALED, AND EXISTING WOODEN SHINGLES DESCRIBED IN ACCORDANCE WITH THE LAW. TO BE PAINTED P I IT4 — ( I k t S 4 1 ALL EXTERIOR BRICK TO BE LIME WASHED EXISTING WINDOW`' EXISTING WINDOWS EXISTING DECK w/9�EW DECKING ALL EXTERIOR BRICK TO BE LIME WASHED CLIENT/OWNER CONTRACTOR TO PROVIDE SAMPLE AREAS TO REMAIN TO REMAIN CONTRACTOR TO PROVIDE SAMPLE AREAS NEW STATS STEEL CAB TO DETERMINE FINAL COLOR TO DETERMINE FINAL COLOR WITH MAHOGANY POSTS ILING _ AIR RESIDENCE _ 855 SOUNDVIEW ROAD rl �T =MAHOGANY POSTS ORI ENT, NY m r. PROJECT TITLE s PROPO5ED REAR ELEVATION (NORTH) RENOVATIONS REMOVE EXISTING DOOR AND WINDOW,REFRAME AND REPLACE w/ANDERSON STORMWATCH r FWGD GOG81-SLIDING PATIO DOOR EX15TING ACCEPT A5 NOTED PATCH AS NEC. INCLUDING BRICK FACE 1/4" = I' DRAWING TITLE I BUILDING ELEVATIONS SCALE AUG 9, 2016 1/4" = 1' DRAWING NO. ISSUES/REVISIONS IN CATHEDRAL CEILING AREA, REMOVE EXISTING INSULATION. PROVIDE 2" CLOSED-CELL SPRAY-IN FOAM INSULATION AND R-22 BATT INSULATION. BIDDERS NOTE: PROVIDE ALTERNATE PRICE FOR BATT INSULATION ONLY. atjs.:NEW y2"GYP. 13 'ter r ON EXISTING RAFTERS 7 •.,, + EXISTING RAFTERS EXISTING INSULATION EXISTING RAFTERS `''' yr, TO REMAIN rw, NEW EXPOSED COLLARTIES NEW y2"GYP'. BD ON EXISTING RAFTERS 42" 1,51 WALL 13F OOM 3G" _ CL D5ET REFI - BUILT-IN NEW HANDRAIL TO ^� r BOOKCASE ENCLOSE STAIRWAY EXISTING STAIR FILL IN BETWEEN JOISTS WITH NEW KITCHEN BY OTHERS. BATT INSULATION CONTRACTOR SHALL COORDINATE NEW STAIR IN INSTALLATION AND PLUMBING AND EXISTING OPENING ELECTRICAL WORK WITH CABINET EXISTING WALL WITH PINE RJ5ER5 INSTALLER. AND OAK TREAD TO MATCH LIVING REFER TO KITCHEN PIANS BY ROOM OTHERS RISE: 7.625" RUN:9.5' RISERS:13 BASEMENT NOTES : PROVIDE 1-112-BATT INSULATION BETWEEN 2-X 4'FURRING MAY 19, 20 16 (FIAT)OVER G MIL POLY SHEETING APPLIED TO CONCRETE AND "GYP. BD,TAPED,5PACKLED AND PAINTED. APRIL 14, 2016 PROPOSED SECTION A DECEMBER 2015 EXISTING ACCEPT A5 NOTED 114" = V THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS WILL BE PROSECUTED 2014 ALL RIGHTS RESERVED 1 1 Robert I . Brown RELOCATE EX15TING HOT WATER HEATER AS SHOWN 14-177 Architect, P.C. ----- -------------� 205 Bay Ave. Greenr®rt NY REMOVE EXISTING I I 7 info raiLir®wnarchitect.com CLOSET WALL5 I I 'I'� G3 1 -477-9752 GOG8 DOOR i I `� 6068 DOORS I � II 1 TO EXISTING LIGHTS I IT IS A VIOLATION OF THE LAW FOR ANY PER50N, L I UNLE55 ACTING UNDFR THE DIRECTION OF A LICENSED ARCHITECT, TO ALTER ANY ITEM ON THIS DRAWING IN ANYWAY. ANY AUTHORIZED ALTERATION 0 0 o 0 D SCRIBEED IN CCORDO D CEE WITH THE LAW. (2) 1-3/4"x I 1-1/4' MICKOLIAM LVL EXISTING CEILING 1 lI i FFF1 H::R SEE DWG A4 �� f UILT-INBUILT-IN CLIENT/OWNER OKC E N BOOKC E 4'-0" PANT BASEMENT PLAN EXISTING ACCEPT A5 NOTED AIR RES 1 D E N C E NEW KITCHEN BY OTHERS. 1 /4• = P ' 555 SOUNDVIEW ROAD CONTRACTOR SHALL COORDINATE ORIENT, NY INSTALLATION AND PLUMBING AND ELECTRICAL WORK WITH CABINET INSTALLER. REFER TO KITCHEN PLANS BY OTHERS. PROJECT TITLE RENOVATIONS DRAWING TITLE BUILDING SECTIONS PROPOSED SECTION C PROPOSED SECTION B PART BASEMENT PLAN EXISTING ACCEPT A5 NOTED EXISTING ACCEPT A5 NOTED 114" = 1' 114" = 1' SCALE AUG 9, 2016 114" = 1' DRAWING NO. ISSUES/ REVISIONS 42 WALL 3'-6 STONE COUNTERTOP -- -- - TO BE SELECTED 36" BR M REFR O D D C L ET 2'-3" 4'-0" 7-0" 4'-9" NOTE: KITCHEN CABINETRY FURNISHED AND INSTALLED APRIL 14, 201 G NOTE: KITCHEN CABINETRY FURNISHED AND INSTALLED BY OTHERS DETAIL / KITCHEN ELEVATION I BY OTHER D ETA I L / KITCHEN ELEVATION 2 GENERAL CONTRACTOR TO COORDINATE WITH KITCHEN DECEMBER 2 I, 20 15 GENERAL CONTRACTOR TO COORDINATE WITH KITCHEN CONTRACTOR CONTRACTOR EXISTING ACCEPT AS NOTED EXISTING ACCEPT AS NOTED REFER TO FINAL KITCHEN DRAWINGS BY OTHERS. I/2" = I' REFER TO FINAL KITCHEN DRAWINGS BY OTHERS. 1/2' = I' THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS WILL BE PROSECUTED 2014 ALL RIGHTS RESERVED Robert I . Brown Architect, P.C. 205 Day Ave. Greenport NY info@ribrownarchiter-t.com 631 -477-9752 IT 6 A V101 ATION CSF 1 HE WX'RX-,AN1'I'F'-','-aON: I!r1L1 3 AGIIN,� UNL'(-1?1I1L`Pl XTION Or A ,L Ll�;LWD AKC:HIILC:T, 10 ALTI_FZ ANL°iiCM ON THIS DRAWING IN ANY WAY. ANY AUTHORIZED ALTERATION MUST BE NOTED, SEALED, AND DF5CRIBED IN ACCORDANCI_-WITH THE LAW. 2x4 FRAME GYP. BD. o FOR FASCIA OVER UPPER CABINETSIT Vi HOOD N N UPPER CABINETS FULL TILE BACKSPLASH t0 3 - — FULL TILE BACK5PLASH 36' RANGE - '-O" _ CLIENT/ R STONE COUNTERTOP AIR RES 1 D E N C E O 0 00 00 0 0 0 TO BE SELECTED 855 50UNDVIEW ROAD ORIENT, NY p p p LOWER CABINETS cn m cn PROJECT TITLE RENOVATIONS DRAWING TITLE NOTE: KITCHEN CABINETRY FURNISHED AND INSTALLED NOTE: KITCHEN CABINETRY FURNISHED AND INSTALLED DETAILS DETAIL / KITCHEN ELEVATION GENOTH ERERA ONTRACTOR TO COORDINATE WITH KITCHEN DETAIL / KITCHEN ELEVATION 4 GGENOTHERS ERAL CONTRACTOR TO COORDINATE WITH KITCHEN CONTRACTOR CONTRACTOR EXISTING ACCEPT A5 NOTED REFER TO FINAL KITCHEN DRAWINGS BY OTHERS. EXISTING ACCEPT A5 NOTED REFER TO FINAL KITCHEN DRAWING5 BY OTHERS. 1/2' = I' 1/2' = 1' SCALE MAY 19, 201 G 114" = 1' DRAWING NO. ISSUES/ REVISIONS PROVIDE NEW RECESSED MEDICINE CABINET. REFRAME AND PATCH AS NECESSARY. CABINET TO BE SELECTED. REPLACE EXISTING VANITY AND LAVATORY REMOVE EXISTING AND PROVIDE NEW FLOOR AND IN WA 1 BASE TILE,TO BE TO L G . P VI E ❑ F-1 SELECTED. MARBLE SADDI F I PROVIDE KOHLER'VEIU WALL MOUNTED TOILET REMOVE EXISTING DOOR WITH 2x4 IN-WALL TANK AND REFRAME AND REPLACE - CARRIER SYSTEM IN AS SHOWN WITH COMMON BATHROOM 2065 DOOR N TO MATCH EXISTING .> PROVIDE SHOWER GLA55 PANEL -ee iLL FROM TOP OF TUB TO CEILING -- - ---` --� lvI HO R S O R ' 5H c® i NENVTUB/ HOWER ® PROVIDE 3G"GRAB BAR- TO ' REPLACE EXISTING PROVIDE BLOCKING IN WALL - ---- - - - ------ COMMON BATHROOM PLAN SECTION I SECTION 2 SECTION 3 SECTION 4 THE5E PLAN5 ARE AN IN5TRUMENT Of 5ERVICE AND ARE THE PROPERTY OF THE ARCHITECT. 1/2" = P 1/2" = 1' 1/2" = 1' 1/2" = P 1/2" = P INFRINGEMENTS WILL BE PROSECUTED 2014 ALL RIGHTS RESERVED 30"WAIL HUNG VANITY MARBLE 5ADDIE TO13E5ELCTEDBY Robert 1 . Brown OWNER Architect, P.C. 205 Day Ave. Greenport NY >/ info@ribrownarchitect.com ® ® NEW TILE FLOOR G31 -477-9752 0 AND BASE 1757— as TOWEL RACK. IT 15 A VIOLATION OF THE LAW FOR ANY PERSON, PROVIDE BLOCKING UNLE55 ACTING UNDER THE DIRECTION OF A IN WALL /"� LICE145ED ARCHITECT, TO ALTER ANY ITEM ON • THI5 DRAWING IN ANYWAY. ANY AUTHORIZED CENTER TOILET AND I ALTERATION MUST BE NOTED, SEALED, AND TOWEL RACK -2 I - + DE5CRIBED IN ACCORDANCE WITH THE LAW. BETWEEN VANITY AND SHOWER FAUCET lie PROVIDE NEW SLOPED G6 SH WE SH WE HO R F O TO CEI NG PAN PROVIDE 24"GRAB o BAR. PROVIDE MO E 15T NG M01 VERLf BLOCKING IN WALL. O J 51 iO\NR EAD t� oil 1111 lr�= w LINEAR DRAIN CLIENT/OWNER PROVIDE 3G"GRAB BAR. PROVIDE IR RE51DENCE BLOCKING IN WALL 855 SOUNDVIEW ROAD ORIENT, NY MASTER BATH ROOM PLAN 5ECT1 ON I SECTION 2 SECTION 3 5ECT1 ON 4 112" - 1' 1/2" - 1' 1121 - I' 1/20 1' 1/2* - 1' PROJECT TITLE RENOVATIONS TITLE BATHROOM ELEVATIONS SCALE MAY I`?, 201 G 1/211 = 1' DRAWING NO. jok ISSUES/ REVISIONS REMOVJAH FIXTUREAND TIL EXISTING CEILING TO REMAIN IN THIS AREA. REMOVE DOOR REMOVE DOOR (TO BE REPLACED) (TO BE REPLACED) APRIL 14, 201 G n DECEMBER 2 1, 2015 THESE PLANS ARE AN INSTRUMENT OF SERVICE \ REMOVE AND I I I _—_� / I------ I I INFRINGEMENTS WILL BE PROSECUTED AND ARE THE PROPERTY OF THE ARCHITECT. REPLACE STAIR 2014 ALL RIGHTS RESERVED WALLS, ETC. I I I EXISTING CEILING TO, TOB;REMOVED i i i REMAIN IN THIS AREA. MII / II i I II Robert I • Brown REMOVE CEILING, CEILING \ I I I I I I I JOISTS AND INSULATION I ( � Architect,ABOVE. PROVIDE TEMPORARY P.C. L_ L__ C -� ——J SUPPORT As NECESSARY UNTIL NEW COLIAR TIES ARE 205 Bay Ave. Greenport NY INSTALLED. info@ribrownarchitect.com /REMOVE CEILING IN THIS A\ n G31 -477-9752 II II IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT, TO ALTER ANY ITEM ON THIS DRAWING IN ANY WAY. ANY AUTHORIZED ALTERATION MUST BE NOTED, SEALED, AND ^ DESCRIBED IN ACCORDANCE WITH THE LAW. REMOVE AND REFRAME SAVE REMOVED BRICK FOR RE05E IN PATCHING SEE DWG A I AROUND NEW OPENINGS i CLIENT/OWNER AIR RE51 DENCE DEMOLITION PLAN 855 501-INDVIEW ROAD EX15TING ACCEPT A5 NOTED ORIENT, NY 114' = V PROJECT TITLE RENOVATIONS DRAWING TITLE DEMOLITION PLAN SCALE MAY 19, 201 G DRAWING NO ISSUES/REVISIONS EXISTING BEDROOM PROVIDE PO RAS NECESSARY FOR NEIN AR I IANDLER IN ATTIC EXISTING OUTLETS TO REMAIN (TYP.) NEW CEILING FAN. PROVIDE BLOCKING A5 NECESSARY NEW CEILING FAN. PROVIDE BLOCKINGAS NECESSARY NOTE: PR VIDE SWITCH AND 3 LIGHT FIXTURE ATTIC SWIT AT TOP OF PULL DOWN STAIR I I I I EXISTING �- I., REMOVE •i BEDROOM-- AND R REPLACQRELOTE EPLACEMENT ELECTRIC / EXISTIO FIXTURES TO BE FIXTURE/ DOPROVIDED BY OWNER / O PROVIDE NEW VENTS WITH REMOTE FAN MOTORS NEW CEILING FAN. PROVIDE BLOCKING AS NECESSARY EXISTING OUTLETS TO REMAIN (TYP-) i A5LOPE MAY 14, 2016 EXISTING OIL TANK TO REMAIN / \ / - SURFACE MOUNTED -TWQRE TO BE SELECTED APRIL 14, 201 G RECESSED IN \ L.E DECEMBER 2 1, 2015 NEW CATHEDRAL �- PROVIDE N CEILING I �L \ REFR RO IDE EW A/C I a THESE PLANS ARE AN INSTRUMENT OF SERVICE COMPRESSOR \ \\ I i AND ARE THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS WILL BE PROSECUTED r _ PROVID HEAVY I 2014 ALL RIGHTS RESERVED DUTY FAN 10'TRACK LIGKING MOUNTED N TO WITH REM TE AN OF ALL COLLAR T4E5 I UNI PROVIDE TOTAL I�,ED LIGHT � _ _ _ __ I EXISTING O GARAGE Robert I . Brown 3 x I PROVIDE Li FOR 15LA D / Q GAS STO�; OP Architect, P.C. CONTRACTOR 5AALL WIRE FOR 4 FLOOR I I CONTRACTOR SHALL COORDINATE 14�IITH MOUNTED OUTLETS,TO BE LOCATED AT I I SUFFOLK SECURITY FOR ALARM SYSTIDAri 205 Bay Ave. Greenport NY THE END OF TAE PROJECT � UNDKR CABINET AND WITH OWNERS AN CONTRACTOR � _ _ _ _ _ _ �� i h(GHT Info@ribrownarchitect.com I I I G31 -477-9752 1 RECESSED L.E.D.\ LIGHT FIXTURES TYP. EXCEPT AS NOTED IT IS A VIOLATION OF THE LAW FOR ANY PERSON, C NEW PENDANT LIGHT / UNLESS ACTING UNDER THE DIRECTION OF A FIXTURE TO BE SELECTED LICENSED ARCHITECT, TO ALTER ANY ITEM ON ztl THIS DRAWING IN ANYWAY. ANY AUTHORIZED NEW CATHEDRAL I ALTERATION MUST BE NOTED, SEALED, AND CEILING EXISTING OUTLETS TO REMAIN (TYP.) ----_ DESCRIBED IN ACCORDANCE WITH THE LAW. RELOCATE AND REPLACE LIGHT FIXTURES OUTSIDE NEW DOOR. CLIENT/OWNER EX15TI NG DECK AIR RESIDENCE 855 SOUNDVIEW ROAD ORIENT, NY ELECTRICAL PLAN PROJECT TITLE EXI5TING ACCEPT A5 NOTED RENOVATIONS TITLE ELECTRICAL PLAN SCALE MAY 19, 201 G 1/4" - 1' DRAWING NO ISSUES/REVISIONS REMOVE EXISTING AIR HANDLER IN f BASEMENT. PROVIDE NEW AIR HANDLER IN ATTIC I I NEW CEILING MOUNTED I I SUPPLY DUCT(TYPICAL) I I L- J DUCT TO BE SIZED BY CONTRACTOR I I C StAIR TO ATTIC I I I I I I I I — I I L__J • I � / O RELOCATE TOILET AS SHOWN NEW LO RETURN RILL NEW HIGH RETURN GRILL MAY 14, 2016 EXISTING OILTANK O _ REMAIN N FLOOR MOUNTED IH APRIL 14, 201 G 5L PPLY DUCT(TYPICAL) 1 � I C��Ct=MC)�RE�I . X01 3G „ I I REFR 7r, K I EXISTING AIC L I fi" )I; riA<`! ARE AN IN5T�,t:ll�.PI Or 5L \ Ct- COMPRESSOR TO I L; �, ,,�_ REPLACED ( CONTRACTOR SHALL COORDINATE WITH AND APL THr- F"orrr,.w Cif=THt-A6WCHI1[-Cl, f 1 _____________ --- - - I SUFFOLK SECURITY FORONTALARM SYSTEM INF`,:ily( M( NT j ti`�'111 Bt` r",*,(��1 am tit) I I C------------- I AND WITH OWNER'S AN CONTRACTOR 2014 ALL RIGHTS RESERVED L-EXI4ING OIL-FIRED BOILER TO REMAIN SINK PROVIDE HOOD P - - ----------- ------------- --- - VVEf WIITH - - - - - - --- -- - - --- - - - Robert I . Brown O MOTOR Architect, P.C. I i 205 Bay Ave. Greenport NY C_______________________ ( I KITCHEN VENT DUCT WITH REMOTE FAN. info@ribrownarchitect.com I NEW AII1 ( DUCT SHALL RUN ALONG ROOF RIDGE G31 -477-9752 I HANDLEIr IN I AND SHALL BE BOXED IN WITH a TYPE W I BASEMgNT I GYP.BD. I FOR FIR�T I�1 FLOORMNG I I I ROOM ND LBASEM NT IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT, TO ALTER ANY ITEM ON DUCT TO BE 91ZED BY _ _ _J THIS DRAWING IN ANYWAY. ANY AUTHORI7_ED CONTRACTORALTERATION UST BE- DESCRIBED IPJ ACCORDAONCE TEDWITH THDE LAW. f_ 3" ROOF aJ Y-'y VENT ROOF - Z- �w �l � !' t. ` BASEMENT NOTES : �{ PROVIDE 1-1/2- BATT INSULATION BETWEEN 2-X 4- FURRING FLA OVER G MIL POLY SHEETING APPLIED TO CONCRETE AND GYP. BD,TAPED, SPACKLED AND PAINTED. ( S 1T - �" Ql CLIENT/OWNER C S tG( SIN ; SINK AI E R R SIDENCE 855 SOUNDVIEW ROAD I st ORIENT, NY LLVV\ MECHANICAL PLAN C.O. 3" 311 11EMATIC LAYOUT TO EXISTING DRAIN PROJECT TITLE DRAINAGE RISER DIAGRAM RENOVATIONS (NEW KITCHEN) NO SCALE DRAWING TITLE MECHANICAL PLAN MAY 19, 201 G SCALE 1/4" - P DRAWING N