Loading...
HomeMy WebLinkAbout41363-Z 4�g�FFU(,fpG Town of Southold 10/19/2017 P.O.Box 1179 0 53095 Main Rd �4,, 0� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39296 Date: 10/19/2017 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 745 Watersedge Way, Southold SCTM#: 473889 Sec/Block/Lot: 88.-5-62 Subdivision: Filed Map No. Lot No. _ conforms substantially to the Application for Building Permit heretofore filed in this office dated 2/7/2017 pursuant to,which Building Permit No. 41363 dated 2/13/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Honig,Peter&Susan of the aforesaid building SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 41363 08-10-2017 PLUMBERS CERTIFICATION DATED Authorized Signature VFot,rTOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE o . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41363 Date: 2/13/2017 Permission is hereby granted to: Honig, Peter& Susan 1787 Hawks Nest Dr Collegeville, PA 19426 To: install roof-mounted solar panels as applied for. At premises located at: 745 Watersedge Way, Southold SCTM #473889 Sec/Block/Lot# 88.-5-62 Pursuant to application dated 2/7/2017 and approved by the Building Inspector. To expire on 8/15/2018. Fees: SOLAR PANELS $50.00 CO -ALTERATION TO DWELLING $50.00 3 E $100.00 Total: $200.00 Buildin4 Insp or Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2110 of 1% lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance-from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing'buildings(prior to April 9,1957)rion-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property tines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00,Commercial$15.00 Date. r� - �_j New Construction: Old or Pre-existing Building: X (check one) Location of Property: 745 Watemdge Way Southold House No. Street Hamlet Owner or Owners of Property: Susan Honig Suffolk County Tax Map No 1000,Section 88 Block 5 Lot 62 Subdivision Filed Map. Lot: Permit No. 62 Date of Permit. Applicant: GreenLogic LLC Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: X (check one) Fee Submitted: $ 50.00 Applicant Signature VjV so Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 •®�� �y�ggg �® roper.richert(a�town.Southold.ny.us C®Utlt7 BUELDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Honig Address: 745 Watersedge Way city,Southold st: New York zip: 11971 Building Permit* 41363 Section- 88 Block: 5 Lot: 62 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Green Logic License No: 43858-ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency FixtureTime Clocks Disconnect Switches Twist Lock Exit Fixtures 9 TVSS Other Equipment: 10.464 KW Photovoltaic System to Include 32- 327 W Panels with Micro Inverters, Combiner Box, AC Disconnect. Notes, Inspector Signature: Date: August 10, 2017 0-Cert Electrical Compliance Form.xls Pacifico Engineering PC _ __ Engineering Consulting 700 Lakeland Ave, Suite 2B / Ph: 631-988=0000 Bohemia, NY 11716 V Fax: 631-382-8236 www. acificoen ineerin com 1' G c solar acificoen ineerin com P 9� 9• .�, @P 9� 9• June 26, 2017 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Susan Honig Section: 88 745 Watersedge Way Block: 5 Southold, NY 11971 Lot: 62 1 have reviewed the solar energy system installation at the subject address on June 26, 2017. The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2016 NYS Residential Code(2015 International Residential Code-2nd Printing modified by the NYS Buidling Standards and Codes 2016 Uniform Code Supplement), and ASCE7-10. To my best belief and knowledge, the-work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice, with the view to the safeguarding of life, health, property and public welfare. Regards, Ralph Pacifico, PE Professional Engineer D AUG 2 1 2017 OF NENr y`� BU.DING Dir. CSP �QN PAC, TOWN TOWN OF 3oumom * o r I f 2�F 2 0- � 0 O,p 661 S2V� R1h neer NY 06 306 ,D )VSP4M6N 1, E2VORIr AAT= FQUNDoION(1ST) - - _.._............. MbM4Tx4N(2Nn) (31 ROUGES YR4IVL1NQ& YLU.M. 3VG --- IINOLATZON•PEA N.Y. � STATE ENEROY CO;DE , I , FTNAL r-..pr....,.'14 I • I . • 1 � • I • r r TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631)765-9502 7 ? Survey SoutholdTown.NorthFork.net PERMIT NO. 7�J Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined '20 Storm-Water Assessment Form rContact: Approved ,20 / Mail to: GreenLogic LLC Disapproved a/c 425 County Road 39A,Southampton,NY 11968 Phone: 631-771-5152 Expiration 120 , ildind In D PPLICATION FOR BUILDING PERMIT FEB ® 7 2011 Date January 31 92017 INSTRUCTIONS BUILDINGDEM T.Mmloltawnwme completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. GreenLogic LLC (Signature of applicant or name,if a corporation) 425 County Road 39A, Southampton, NY 11968 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Contractor Name of owner of premises Susan Honig (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. 40227-H Plumbers License No. N/A Electricians License No. 43858-ME Other Trade's License No. N/A 1. Locatiioof land on which proposed work will be done: House Number Street U V Hamlet County Tax Map No. 1000 Section 88 Block 5 Lot 62 Subdivision Filed Map No. Lot • 9 2. State existing use and occupancy of remises and intended use and occupancy of proposed construction: a. Existing use and occupancy Single family dwelling b. Intended use and occupancy Single family dwelling 3. Nature of work(check which applic ble):New Building Addition Alteration Repair Removal Demolition Other WorkRoof mounted solar electric system (Description) 4. Estimated Cost $39,000.00 Fee Z0 (To be paid on filing this application) 5. If dwelling,number of dwelling uni s Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, i any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front ? f �� ��° Rear--`f'... F : ' Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth N`, ,•� 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO_X 13. Will lot be re-graded?YES NO X Will excess fill be removed from premises?YES NO 745 Watersedge Way 14.Names of Owner of premises Susa Honig Address�o i�l(i, NY 11971 Phone No. 631-655-9596 Name of Architect Pacifico Engieering PC Address700 Lakeland Ave,Bohemiaphone No 631-988-0000 Name of Contractor GreenLogic LILC Address 425 County Road 39A Phone No. 631-771-5152 Southampton, NY 11968 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES X NO * IF YES, SOUTHOLD TOWN TRU TEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet o�a tidal wetland? * YES X NO * IF YES,D.E.C. PERMITS MAY B REQUIRED. 16. Provide survey, to scale,with accu late foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO X * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Nesim Albukrek being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract above named, (S)He is the Coptractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authirized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief,and that the work will be performed in the manner set forth in the plication filed therewith. Sworn to before me this day of �O 1'7 Notary Public rSignature of Applica t SAMANTHA CORSE_TT Notary P6L4ic,State of New York Reg. .01 CQ6335944 QualirlW in Suffolk County C�ornm sslon Fires January 19,2020 I Scott A. Russell STOWWAWAT]EIK SUPERVISORAMIA&NAGIEMIENT SOUTHOLD TOWN HALL-F.O.Box 1179 f 53095 XWn Road-SOUTHOLD,NEW YORK 11971 Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET (TO BE COMPLETED BY`T APPLICANT) DOES =8 PROJECT 11 �%r"OLN7E ANIY OF THE FOLLOMTINIG. (CHECK ALL THAT ARM Yes \40 A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ®El B. Excavation or filling involving more than 200 cubic yards of material within any parcel or an), contiguous area. C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. it I []EJ D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. OEI E. Site preparation within the one-hundred-year floodplain as depicted on FIRM Map of any watercourse. F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information,Date & County Tax Nap Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above,please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with y-iur Building Permit Application. -­ I Date APPLICANTP (Profwrty Mna.Design Pjofeb�,ional,Agent,Conttractoj.offia" S.C.T.M. 10Di�00 lrlct NAME, Greenl-oqi LLQ (Nesim Albukrek) 88 5 — 62 2/1/17 , sectiosectionlh��k Lot A Ak r W FOR BUILDING DEPARn-IENT USE 0 NLY Coatactlnfor=uom � 631-771-5152 Reviewed B4: a�p — — — — — — — — — — — — — — — Date. Property Address/Location of Construction Work: — — — — — — — — — — Approved for processing Building Permit. 745 Watersedge Way, Southold, NY 1971 — Stormwater Mmiagement Control Plan Not Required. Stormwater Management Control Plan is Required. it -- — — — — — — — — — — — — — — — rito Engineering Department for Review.) ---- ----------- FORM SMCP TOS MAY 2014 4��t1F Sti�r�D� � o Town Hall Annex Telephone(631)765-1802 j 54375 Main Road I P.O.Box 1179 G Q roger.richert _own sout�io� .nv.us Southold,NY 11971-0959r� BUILDING DEPARTMENT TO%W OF SOUTHOI D APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Samantha Corbett Date: { Company Name: Greenwgic'LLC Name: Robert Skypala i License No.: 43858-ME Address: 425 CountV Road 39A Southampton, NY 11968 Phone No.: 631-771-5152 I JOBSITE INFORMATION: (* ndicates required information) ars) , *Name: Susan Hoag _ *Address: 745 a Way, Southold NY 11971 *Cross Street: Bay Haven Ln *Phone No.: 631-771-5152 € Permit No.: Tax-Map District: 1000 Section: 88 Block: 5 Lot: 62 *BRIEF DESCRIPTION OF WORK(Please Print Clearly) -Roof mounted solar electric system. 32 327W ACPV panels. 10.464kW. (Please Circle Ail That Apply) Is job ready for inspection: YES NO Rough In Final *Do you need a Temp Certificate: ES NO Ternp Information(If-needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82z-Request for Inspection Form PC f 3 _(3�GREENL®GIC® ENERGY February 1, 2017 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Dear Building Inspector: Please find attached a building permit application on behalf of Susan Honig who has engaged us to install a ground-mounted solar photovoltaic (PV) electric system for their home located at 745 Watersedge Way, Southold, NY. In connection with this application, please find attached: • Building Permit application • A Storm Water Assessment Run-off Form • Certificate of Occupancy Application • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports (3 originals and 1 copy) • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels • 2 Spec. sheets for Racking System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200 ($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, samaad Samantha Corbett Account Manager Samantha.Corbett@Greenlogic.com 631-771-5152 ext. 107 GREENLOGIC LLC o www.GreenLogic.com Tel. 877 771.4330 Fax. 877.771.4320 SOUTHAMPTON ROSLYN HEIGHTS 425 County Rd 39A 200 S Service Rd ,#108 Southampton, NY 11968 Rosyln Heights, NY 11577 J.mss. T a: . GREENLOGICO ENERGY August 15, 2017 D GCCEOV[2 DD AUG 2 1 2017 BUHMING DEPT. The Town of Southold TOWN OF SOUTHOLD Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Re: Building Permit No. 41363 Susan Honig 745 Wateredge Way, Southold To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the above referenced address. Can you please close the building permit and send the Certificate of Occupancy? Please let me know if you have any questions about the installation. Sincerely, Sacs"fff:ac d"&& Samantha Corbett Account Manager Samantha.Corbett@Greenlogic.com 631-771-5152 Ext. 107 GREENLOGIC LLC o www.GreenLogic.com Tel 877 771.4330 Fax: 877 7714320 SOUTHAMPTON ROSLYN HEIGHTS 425 County Rd 39A 200 S Service Rd , #108 Southampton, NY 11968 Rosyln Heights, NY 11577 SO!/r�ol Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G Q Southold,NY 11971-0959 �O October 10, 2017 l�COUNT`(,� --n'rBUILDING DEPARTMENT / c3 TOWN OF SOUTHOLD ;/// Greenlogic LLC L_, OCT 18 2017 425 County Rd 39A Southampton, NY 11968 _ y T DEPT. �EPTry1 E�'J r�fiiA a�Tf�.+f . Re: Honig, 745 Watersedge Way, Southold TOMIN OF SOUTHOLD TO WHOM IT MAY CONCERN: Z_ The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: NOTE: Certification letter required from Engineer stating the panels were installed to the roof per NYS Building Code Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) TrustPpes Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Punning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 41363 - Solar SITE DATA 1,.` \�•YI SCTMD 10094045fi2 s•.i'7��'\^" PROPERTY INS Watersadge Way �ci-y�� Southold,NY 119.1 .� ✓ 1QO�Q OWNER P7,ar 66usan Hanig 1 NI r ` 1107 Hawke NPat odve ,r ' N Collegewllc,PA 19426 SITE 16 852 SO FT=OJB AC Tn �� AREA �E -pp 20NWG R-00 oiN NrN FLO+v S !`` LOTCOVERAGE 20% B LBELOn sragDE\• E \ I ALLOWABLE 3370SF EXISTING UJ •• i. 1 -- SS5i9 3' ➢' PROPOSED2 2900 SF Z FLOOD zone% O 0,0 TEMPORARY STORM WATER GT t`Iwv[T 1 zaNE f;• Z RUNOFF CONTROL MEASURE In SURVEYOR P....1.Surveyors W 1 EROSION SSEDIMENTCONTROLDETAILS ➢\ - 1239 Traveler III— TRE WZ .(� , Southold,NY 11971 wu T NY LIv No 49610 a DATED July 0,1998 ul 1 I Revised Aug 1S 201] _cn EXI5TING DRRAY ANEW LOCATION MAP o o uj GENERAL STORMWATER POLLUTION PREVENTION NOTES NEW BEL / �' b'DIA x 4'D NEN BE REO'D IT-5 D¢YWELL �' PERMANENT STORM WATER RUNOFFCONTROL MEASURE / NEW METER It7' Q SITE OESCRIPTIONBGENfRAISEODENLE OF SITE ACTIVITIfSFORTNE ENTIRE SITE 'GRA` PNEW LOCAnGV rI"'T.+iDE • �J --�----N�°+EW BILGO I"ARD },ii O J ocsumam aneasrm mapoP.enarw+r.Nl due lx+I neaa uawral Paa<unl2 XIGT BELGUIM ADDITION l o RAT 5ETBAGl J1a �j —At.anu.a5`mµN I ELK CURBING E 5T STAIR 1 Z L F , 1r7 W p7 u.nm, ear bmror:l.,]Ban'.' '�a-' re � . t O cenm, ra„ IMS' ;-exlsr ��y�i" =N R.,na.-.r ulva amP„o<v"n l+Ns rnm,VrPs•rc I�aa>,n arow rv, 14ID 5AO—� EXISTING , I,WExAlLsr Y ii SITE SITE DATA SIleasz sP.o3P nc GARAGE R G ,a NA W.au` Ni r` POLLUTION CONTROL MEASURESF?EGOG'BAY'ci l'i15< sm.r,aa neaa.r.asa4m..rr I - }'�i� ESC15TING ��----�I_� eam' ''�<.e<MSB.a<rmM.w�.a nm,,:m„Iw sua.<9 caaz„s+9eB e,..g R,aL« f -RE5IDENCE _ --I-I— O'�ewNwcr.aro dw e<.<+rw�wna lav mxvbemmrv,...a.��r,nv,.,rwmae��w,m.rr.r I r0 � _ I?S.J..I B a-Pmoc ..emc•+m��>yez.norPMei,rsuEc�.,o-a / X\ 1 - � - InevP=r.nvr maeo nmee,m„r.v'�,gnae+-uvm<amwrb vnrvn,e-„9rami semr.r.n.n x,a z+.J L amnmuryN,un<nnwarBaemarevwvov;m.ano.amnrv,an'rvv.e9r,mxroonm,i<wearevwnaa4,oeraamrvaPa..Na ma.e<.rrr4'�>,nIamm.N m v iM..ear=.ve r rb r iV IIS.KnAY Wq e2i'wtaewlr BrAOOeJS,6,Pwawaeb.-,Pa walla®ulW we) ,iYy^-- �J P35@�:} n4 RfN�m�us�lurn'umcrwmrcr.,pa3e my Pv euP 10]N>uar,PWw el ` • r ', ti�eai Ew i?8C 'ate ,m„awa 9.I�,B4rWParx,al2l�.Pa,r�a=ulI„�.,,a„9„e,.La�., I a� as vOdO°"m�"M""R' 4 I [xlsr Bx15nNG I rnm brgrhma enuP<asdwnaaargr.a>r..e ev nrnmrnalo raP..ro wvAretum Rwa4 rwerowwna...w Bu+. 'COV=REDI DECK vaP,aem va vban.mwmm.amen,.npa,Iav�.ron:ua.mesP•4r�yvavuma , r '! PORCH I r� s�ne+'e'I rurrnmsneevmr�my.bl.t MM:aM�o-.<.<4A.m wl+�«r.oo+ �➢,1 �---rT— Ll ” `��Po.`"`a�me�m..a y<bm�aP„ew..mwvr.wanar..w mapr+x aAPa«B.ma w�aawr Pn,W1m tp ,rv,m or,..awzPPPra�aar.I o,warnm I o N` _ Rr�raoP.n<��•.nw��',nerarvm a.a w,m9,.v=m,m,a O p r�1 omm>a rw�vaz�am�urPea<.v.>mrr ne<uuwao,>o..,a mn-.amm+.rvw+.r.r.ms>^w ra .S2 O = mw.aWarPrnaP.am,.aa.er„mPxery„�nr<m.a,eTrm a,rraa.urvrv+�n Q 4 e'mrWa W va rol b",nee o rJeam+o4(reLrww W We stm,ra'�I ue a sweUrF+uua'oen�'y aN rew'.eer o A,1 PROJECT NO dF POPeyvnwrary 1t 3 15024 O,3 rrcum en wnvsaws ew'b-a.�v'.4y wnY+o�il �macm.^M vac ulwnar9¢roe ae DRAWN By b Rnn'rv4aq.-�n aneouwrnm d�aumttrer.rn mmWrm un bunt'nlaumn'aicnnvxa.Uaa ne^raary -"51N��1 UT mmuPrwy4ebremvm✓mM nMglre r,m+p+ay cva nN ervWrrm nmrynareTrevry I "�Y\ I� CHECKED By HEC DBY NS eno«nenS sMvreeny rde mraeanarmwu<manmuesa \ n DATE m�Em^rm�an...7m mr mrnnn rrewwv mv,re nrvA� n OCT 10,2016 SCALE D—RIPTION OF CONSTRUCTION AND WASTE MATERIALS STORED ON SITE 1 VI 7•=10•_0• m.wgLnmrvn>.crrwveuv.rvatv,ams p,ww,cr.<a SHEETTTLE Na ur�u�Prera,�m 9 raw 1 o s rnw ur waa man aa,gu m'ur�uar4w'N miV.i,�wl a�a�,wr"' ,.>ra,ery aw,N wwwsmb.a e,,,emo-,-e.mm.r�.,a„avmwa ,'ypOD�yKNEP9 SITE NxeO,rM numanu endrWmmrr<nnnec<M va.maa unn9«mpmy O EX`yS1 9108 PLAN SITE PLAN i NEAN N1C' J' SCALE 1"=10'-0” SHEET.. SP SITE DATA SCTM• 100048-0542 PROPERTY 745 WAmrwdpd Wry Soalhmld,NY 11911 �OOWN �U OER P°br 89uian Honip ,(1 'i 1T81 Hawb Nast � C011apwply,PA 1942 64fi /pi LTM n ARE 18,857 9D.FT m p38 AC J AREA FlLTER UATNb ort x°�AGe �j ZONING R40 n•BB.oW� � �'� L1 __ LOT COVERAGE 20% -"~y',\i\ \'Y•�.z�. 55fi�930'' ` y` ••� I EE(LiSMG 26473370 SF SF !A WY PROPOSED 2908 SF Z �O TEMPORARY STORM WATERll�—``n1`_ ) FLOpo zono K O ). RUNOFF CONTROL MEASURE a ISTi f mNE F Z SURVEYOR P �w1EROS10N 8 SEDIMENT CONTROL DETAILS n b 10SImay1m p W W S , NY L(°N.A9818 Q ( +� DAZEJD uly S,8 LU� ' EXISTING / I R.A.d ABp 15,2015 3,: DRE ;Y W-A I LOCATION MAP o 0 VUj GENERAL STORMWATER POLLUTION PREVENTION NOTES NEW BELs IT'-S° O9 VIA X 4'D PERMANENT STORM WATER RUNOFF CONTROL MEASURE I B� Ob F SITE DESCRIPTION A GENERAL SMIJENCE OF SITE ACIMTIEB FORTiE ENTRE BRE /EDGE OF NEW METER 10 Q De"bwbmvaNaeabubpolenMwdata ATION �{�ql, t ueamnatmmmarvm>mnmio-dmvawrnluvmrcmm.nav)e>naWeta IST BELNJIM ppppOOR �. GURBIN6 Z= x�ryurlmawPNbmeo mwmm Sm 0.on � DLK ExIST STAIR SETBAGY{ � O O IF+omm�nue�wwwwslvE1Oiaww4ib°npisl pOO"b°im •'e✓d'IY+�'�.' z O b. vcd'wcaru.Immmrew+.a IIS-15, r...� -,.�,--•.,r....X rrr� 1 Fnroitl of ve mrrPowymm,mmwd m>e>w°> I SIDE ••rr••J tl- �U ::.;.•w,i.; ^;::'`•%;:r„'r ExIST Y "s i 0 D, sRE DATA ETBAGK SITE D Arm te&Sa SFvv I GARAGE .-yam,', �� (xEXIST POLLUTION CONTROL MEA9URE8 ����.,;:-','. •"x�.-`,. �w='"�Y": _ In emomeme Wmn�opoAVmv ofba Twndbwndv wdwa3o emrm wdmmmmmvmalaM amimemvadrrme I ��.^«�;";,,,. r w BaavrN�mmdmrmmm wnmPwq°e ler>wae.vmamn>wdlm aammdm.mgmaa ambmlmad'm �-""''�""''�'"•" a,;^ry�M��E51DENGE�.��r y" _' aaovmawGmaae womedmaWe.°.>mmmmma mo aamnaa.Pmmwanemuma�Nnawnoum daa°m yf'w* - ._ �'; •"'-;. �= „--.. mmOsma AnmammoetewdW maamevvamatlmv urksswdmn G>nrh>mb0-+rv.vMP°NYSOEC OrmoO F`.y''" �� i��.r.•,=., .,+. v�mva vlW mWq Wdrm uvwdrue moamntmrrrvwdrgearmuim.smamnuavmvma / NEW 'x" w �K-�ry,•=: ca,mwa°m>nme wmm�mu�eaivi°e>r>mewo�0 w� ,� mroa,wm maawmxat mv.m.vam.v" Y 6_4'':•>^c�;. ;„'�',`H,M"~,„'","; f, mz w° w mammvmamanmdaaawviamaa.um dm>wemmomaemmmeidr ` =-", :��•:ss;^ - w°w=em-*a.er.°oedremw.�owwmtrm"am,mn».warmnnm mwo>. r.•�-,=:,.=i'L:,,• r.m, :.,; �a �¢3� ST °R;asm..(wm,wmcwmm7Oad m.rmave corm.im,.0oownl =',-�:N.-.:"%^. ;.,•;•:•__"_.r'.'r.^. �w. @�3 mCmeem'Nvmbov whmrwo(mmelwal�lvoM wrew Rbmaw,Am va v)v,owlnmrryotivmmmin ` V�i' II I' III' li'',' Til QF VEFv ovum.ea°mO�mnOoiy.sm,mWwmPgaa 11"-I'll E>�I I'I fJ(p15�7ENsi, m m• me�vm mea�ro'N»admm>aw..nW mRm,.�nmmaam.mdT.owm>.R.mn wom°."ma°mo=m 1 ISI Gp.'CREvI ill,IK,i� E Sa°evawd H°ACo wo°Wmm neuta.m Mwndmabadw o$xmtce9e*mamwubrmmmar>irew.ramm. \ i'Dill IF'I,i f�l i,' 'I i I'i I, i maama.aN mai.waora.wro,�mnmrmw>u,ammwdm�mawvmm,w>umvw 1 I, I' wmmmdr�� 1 iaaamm awm�m.wmmmm�°1mq.•emvmma>o<aaemr,ammma v>o.a omomm wm.Tne a� nmwmtlmdm0°v°imamcaagea .° Wis°h°T"ul ne dale nmtlY Wbtam Mva°6mmrrnrluE°moodtbm>,>meo aaod.eTwemmm�� av>o-�Na���.orwwv+,mew>memmemam X201 NaGP°Plvierrox�n mnmumEbmn>oramvuugwmeuWn I ��1Q `I,I m rowimm�wTmm:amn o-w°a".womaemmdmed.eavemwdaw�.>vWm>.mnm ,» _ z �.d„ m.�m°�8a.n mmm4Pmwm>bm�aaw�.mv°Irmawe,hmegmm "( nmNeewrrmuwae+my mbM.v 6ryawhmwdeNy mmmv rudm Pvvm Wnorm autumn atww,rn wamww"maM._ mlmmam ammma.emm>xdmw„mae ma"rwab wmma m°mwaar �o amwgvm mPwaawgolvdm>mwwu f�> rLlmrrN m1p'ewr+°�°am.mm,mvwPROJECT NOn.vmwmadmw mmammawaaw>+lamawam.mamm>aa a01 3 maew nw.amwaam.awmawaearv>..arvmmpm>rama nPmvw TmrPwrvrwm.y 1502A 'o msm 0.+n dmvnvmpammmtaumddan moods"mmwamme T"mntraaovlW mAmaH CRAMS o.vidm•aamaoma mm earq n.mmm,.rvmmoam mrobmo anaraerwdvnv I OL I.r^O UT CkECHEG .nremn.rrrwe°em°mrrrunmwswwP,wmvwwnyrn w�aone mm�avuummmuesm By NS vm Friphmnamam mrrmam dnvaWVPPwbd R>vPt•*e. 1 h DATE OFSLRIPTON Oi CONSTRUCTION AND WASTE MATERIALS STORM ON SITE SCALE rn OCT 10,2019 Wmvmam marmdawearLm cmmremmao°army Imawp amdmam mmmmammimrmiww q®nammna 1' .10 -0' imaranow vb,.arm P>mvrloa°mmmawmmw.m(.lneoww ewv mmm ewhgmnrmau nwmmrmwgw SHEET TRUE 4drgmarmW yeng mw"n pmwhvvamwLv>ma'nwvo mvm mvvnddaa Wubvm ggrN bpamEmp wlmm melmwv W>smmetwbNuvlertletlorNabnmamNaM1°n lm Na6,g miatrq evuque uwa>Odna'rgmarmWacnO moE"de mm emn mrdawAm wwem>meW waamda I•r�.d.m we m...m�w,°.m...,>®m.rmm W wmbmw�r W fl Bu+-K"Ep° SITE .mrm.ma,mo>rm,>em.rrw+a.rnm.o-lmv,�mvmmm�r of Ex9sIO BT 99 PLAN SITE PLAN SCALE' 1"=10'•0" NBRA1'10'w ,/G� SHEET NO P 8�� S P APPROVED AS NOTE DATE: ° B.P.##��, ;Ot\f` L .tliTi ALL CODES OF .a�® � r,=1 !YOR�� ST1� -E &TO\JiIN CODES FEE: . �i_ a ._ . .� � ��- NOTIFY BUILDING DEPARTMENT AT AS REQUIRED 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: ,$@ARQ 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE SDI'; QInTC�fNC�ITRUSTEES 2. ROUGH - FRAMING & PLUMBING -� � "��"� 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C 0. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW OCCUPANCY, `�� YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY , �oFF Rik W A��R Ru2 6 lex VI PacificoEngineering PC _ _ __ Engineering Consulting X700 Lakeland Ave, Suite 2B Ph:631-988-0000 Bohemia, NY 11716G[NR1IG solar@pacificoengineering.com January 27,2017 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Susan Honig Section-Block-Lot. 88-5-62 745 Watersedge Way Southold, NY 11971 I have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions I have determined that the installation will meet the requirements of the 2016 NYS Residential Code(2015 International Residential Code-2nd Printing modified by the NYS Building Standards and Codes 2016 Uniform Code Supplement), and ASCE7-10 when installed in accordance with the manufacturer's instructions. Roof Section A, B, D, &E C Mean roof height 22.0 ft 22.0 ft Pitch 14 degrees 14 degrees Roof rafter 2x6 2x8 Rafter spacing 16 inch on center 16 inch on center Reflected roof rafter span 13.2 ft 13.2 ft Table R802.5.1(1)max allowable 13.3 ft 16.9 ft The climactic and load information is below: Ground Wind Live Load, Point CLIMACTIC AND GEOGRAPHIC Exposure Speed,3 Pnet DESIGN CRITERIA Category Snow Load, sec gust, per pullout load, Fastener Type Pg,psf mph ASSCECE 7,psf lb - Roof Section A B 20 130 33 452 (2)4.5"#14-13 DP1 concealer screws B 33 452 (2)4 5"#14-13 DP1 concealer screws Weiaht Distribution OF iliEF� array dead load 3.5 psf 1/y load per attachment 47.9 Ib Cb P\,PH PgCO� Subject roof has one layer of shingles. �;r � �p Panels mounted flush to roof no higher than 6 inches above roof surface. a }W C7 , Gti Ralph Pacifico, PE i Professional Engineer N� alaph�Aci c�Freffe3 I ,�l�n�gin'e NY�ossf�8��CS��I��".'as GREENLOGICO ENERGY GreenLogic,LLC Approved Susan Honig 745 Wateredge Way Southold,NY 11971 Surface#A: Total System Size.10 464kW Array Size:1.962kW 1 Circuit of6 on a 20A Breaker Azimuth 214° Pitch:14° Monitoring System: Sun Power ;t_ Panel/Array Specifications: Panel:SPR-E20-327-C-AC Racking-Sun Power Invisimount Panel:61.39"X 41.18" Array: 15'5 5/8"X 10'3 9/16" Surface:31'1"X 16'4" Magic#• Invisimount Legend: ® 6 Sun Power 327W Panel ® Sun Power Invisimount Rad • 18 Eco-Fasten Quik Feet B2x6"Douglas Fir Rafter 16"O.C. N otes Number of Roof Layers. 1 Height above Roof Surface.4" Materials Used.Eco-Fasten,Sun Power Added Roof load of PV System 3 5psf hit Engineer/Arcect Seal: ` of NE�Y �P ?\A PAC/CO ,� o.A x{11 W 0661 B OFESSIO�P�' Drawn By:MMB I Drawing#1 of 17 Date:1/20/2017 REV:A r Drawing Scale:3/16"=1.0' GREENLOGM ENERGY Green Logic,LLC Approved Susan Honig 745 Wateredge Way Southold,NY 11971 Surface#A: Total System Size:10.464kW Array Size:1.962kW 1 Circuit of 6 on a 20A Breaker Azimuth 214' Pitch:14' Monitoring System. Sun Power 5t— Panel/Array Specifications: Panel:SPR-E20-327-C-AC Racking.Sun Power Invisimount Panel:61.39"X 41.18" Array 15'5 5/8"X 10'3 9/16" Surface:31'1"X 16'4" Magic# Invisimount Legend: ® 6 Sun Power 327W Panel ® Sun Power Invisimount Rad • 18 Eco-Fasten Quik Feet 2x6"Douglas Fir Rafter 16"O.C. Notes. Number of Roof Layers: 1 Height above Roof Surface.4" Materials Used:Eco-Fasten,Sun Power Added Roof load of PV System:3.5psf Engineer/Architect Seal: rr, 0 ZN - �O 0661 SZ 4�PESSI Drawn By:MMB Drawing#2 of 17 Date:1/20/2017 REV.A Drawing Scale-3/16"=1.0' .. GREENLOGICO ENERGY GreenLogic,LLC Approved Susan Honig 745 Wateredge Way Southold,NY 11971 Surface#A: Total System Size:10.464kW Array Size 1.962kW 1 Circuit of 6 on a 20A Breaker Azimuth.214° Pitch.14° Monitoring System: Sun Power Panel/Array Specifications: Panel:SPR-E20-327-C-AC Racking:Sun Power Invisimount Panel:61.39"X 41.18" Array:15'5 5/8"X 10'3 9/16" Surface.31'1"X 16'4" Magic#:Invisimount Legend: ® 6 Sun Power 327W Panel 1 Sun Power Invisimount Rad • 18 Eco-Fasten Quik Feet a2x6"Douglas Fir Rafter 16"O.0 1 N otes: Number of Roof Layers 1 Height above Roof Surface-4" Materials Used Eco-Fasten,Sun Power 1 Added Roof load of PV System-3.5psf Engineerj&chMgctt Seal: ��.QF NCW\A PAA Y �P VQ"Z:Z!� m w �O 0661$ PESSIONP�' _ Drawn By MMB Drawing#3 of 17 Date: 1/20/2017 REV:A Drawing Scale:3/16"= 1 0' ENERGY GreenLogic,LLC Approved Susan Honig 745 Wateredge Way Southold, NY 11971 Surface#B: Total System Size: 10.464kW Array Size-2.943kW 1 Circuit of 12 on a 20A Breaker(shared with S#C) Azimuth:124° Pitch:14° Monitoring System: 2 SunPower Panel/Array Specifications: Panel.SPR-E20-327-C-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'7%"X 10'3 9/16" Surface:32'7"X 16'6" Magic#:Invisimount Legend: ® 9 SunPower 327W Panel ® SunPower Invisimount Rail • 24 Eco-Fasten Quik Feet B8 2x6"Douglas Fir Rafter 16"O.C. N otes. Number of Roof Layers: 1 Height atiove Roof Surface•4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System.3 5psf Engineer/Architect Seal: OF NE►I/y I eH PA C/ 0 COn • 2N � Z �rya¢a- (n0 06618`L A�OFESSIO�P� Drawn By:MMB Drawing#4 of 17 Date:1/20/2017 REV.A Drawing Scale:3/16"= 1.0' 0� (045� � ENERGY GreenLogic,LLC Approved Susan Honig 745 Wateredge Way Southold,NY 11971 Surface#B: Total System Size:10.464kW Array Size:2.943kW 1 Circuit of 12 on a 20A Breaker(shared with S#C) Azimuth:124° Pitch.14° Monitoring System 2 SunPower Panel/Array Specifications: Panel:SPR-E20-327-C-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'7%"X 10'3 9/16" Surface•32'7"X 16'6" Magic#:Invisimount Legend: ® 9 SunPower 327W Panel ® SunPower Invisimount Rail • 24 Eco-Fasten Quik Feet BB 2x6"Douglas Fir Rafter 16"O.0 Notes. Number of Roof Layers. 1 Height above Roof Surface-4" Materials Used.Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Enginee�Architept Seal:A OF N E 1 �P P�PN P� j'��OO�� C7 m N L= C66182 ROFESSO, Drawn By MMB Drawing#5 of 17 Date. 1/20/2017 REV:A Drawing Scale:3/16"= 1.0' M�ntr GREENLOGICO ENERGY GreenLogic,LLC Approved Susan Honig 745 Wateredge Way Southold,NY 11971 Surface#B: Total System Size:10.464kW Array Size:2.943kW 1 Circuit of 12 on a 20A Breaker(shared with S#C) Azimuth:124° Pitch:14° Monitoring System 2 SunPower Panel/Array Specifications: Panel:SPR-E20-327-C-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array-20'7 3/"X 10'3 9/16" Surface 32'7"X16'6" Magic#:Invisimount Legend: 2 ® 9 SunPower 327W Panel ® SunPower Invisimount Rail • 24 Eco-Fasten Quik Feet 2 B a 2x6"Douglas Fir Rafter 16"O.C. Notes- Number of Roof Layers: 1 Height above Roof Surface:4" 2 Materials Used.Eco-Fasten,SunPower Added Roof load of PV System-3 5psf Engineep/Ar ect Seal: pF NEW Q ti .. xaas � N�OA 66618 �QFESSOA! Drawn By:MMB Drawing#6 of 17 Date:1/20/2017 REV:A Drawing Scale 3/16"= 1 0' GREENLOGICO ENERGY GreenLogic,LLC Approved Susan Honig 745 Wateredge Way Southold,NY 11971 Surface#C: Total System Size:10.464kW Array Size-0.981kW 1 Circuit of 12 on a 20A Breaker(shared with S#B) Azimuth.124° Pitch:14° Monitoring System, Sun Power Panel/Array Specifications: Panel:SPR-E20-327-C-AC Racking-Sun Power Invisimount Panel:61.39"X 41.18" Array:10'3''/Z"X 6'10 3/8" Surface:19'2"X 11'6" Magic#. Invisimount Legend: ® 3 Sun Power 327W Panel ® Sun Power Invisimount Rad • 10 Eco-Fasten Quik Feet H2x8"Douglas Fir Rafter 16"O C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten,Sun Power Added Roof load of PV System-3 5psf Engineer/Architect Seal: 0NEFbY CO� PN PAC/ O Q� P, ` IK N znuro r,+� V �O 0661'8 �RO�ESSIO, Drawn By:MMB Drawing#7 of 17 Date- 1/20/2017 REV:A Drawing Scale:3/16"= 1.0' '. c ter. '" L. M - ENERGY Green Logic,LLC Approved Susan Honig 745 Wateredge Way Southold,NY 11971 Surface#C: Total System Size.10.464kW Array Size:0.981kW 1 Circuit of 12 on a 20A Breaker(shared with S#B) Azimuth 124° Pitch:14° Monitoring System: 2 SunPower I Panel/Array Specifications: Panel-SPR-E20-327-C-AC Racking:SunPower Invisimount Panel.61.39"X 41.18" Array:10'3%z"X 6'10 3/8" Surface: 19'2"X 11'6" Magic#:Invisimount Legend: ® 3 SunPower 327W Panel ® SunPower Invisimount Rad • 10 Eco-Fasten Quik Feet B2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System-3.5psf Engineer/Architect Seal: OF- NEIL P H )AC/ 0 CO �' LLU Z _ 06618 A) 06619 Drawn By MMB �Drawing 8 of 17 Date.1/20/2017 Drawing Scale:3/16"= 1.0' G GREENLOMCO ENERGY GreenLogic,LLC Approved Susan Honig 745 Wateredge Way Southold,NY 11971 Surface#C: Total System Size. 10.464kW Array Size:0 981 kW 1 Circuit of 12 on a 20A Breaker(shared with S#B) Azimuth:124° Pitch:14° Monitoring System. 2 Sun Power Panel/Array Specifications: Panel:SPR-E20-327-C-AC Racking:Sun Power Invisimount Panel.61.39"X 41.18" Array.10'3'h"X 6'10 3/8" 2 Surface:19'2"X 11'6" Magic#: Invisimount Legend: ® 3 Sun Power 327W Panel 2 Sun Power Invisimount Rail • 10 Eco-Fasten Quik Feet a2x8"Douglas Fir Rafter 16"O.0 Notes. Number of Roof Layers, 1 Height above Roof Surface:4" Materials Used:Eco-Fasten,Sun Power Added Roof load of PV System.3.5psf Engineer tect Seal: OF NE N C O'A b Z ®A 0661-9 ROFFSS100�� Drawn By:MMB Drawing#9 of 17 Date:1/20/2017 REV:A Drawing Scale:3/16"=1.0' ENERGY GreenLogic,LLC Approved Susan Honig 745 Wateredge Way Southold,NY 11971 Surface#D: Total System Size:10.464kW Array Size.1.308kW 1 Circuit of 7 on a 20A Breaker(shared with S#E) Azimuth-214° Pitch: 14° Monitoring System. SunPower 5t— Panel/Array Specifications: Panel-SPR-E20-327-C-AC Racking.SunPower Invisimount Panel:61.39"X 41 18" Array:10'3'/z"X 6'10 3/8" Surface:21'3"X10'9" Magic#:Invisimount - Legend: ® 4 SunPower 327W Panel ® SunPower Invisimount Rail • 12 Eco-Fasten Quik Feet B2x6"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface-4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System-3.5psf Engineerlgrc itect Seal: OF PA 7 0 Co W 'C Ii5L5 r/1 066182 ASS\ONP� Drawn By:MMB Drawing#10 of 17 Date:1/20/2017 REV.A Drawing Scale:3/16"=1.0' GREENLOGICOENERGY Green Logic,LLC Approved Susan Honig 745 Wateredge Way Southold,NY 11971 Surface#D: Total System Size:10.464kW Array Size:1.308kW 1 Circuit of 7 on a 20A Breaker(shared with S#E) Azimuth*214° Pitch:14° Monitoring System. SunPower Panel/Array Specifications: Panel:SPR-E20-327-C-AC Racking-SunPower Invisimount Panel:61.39"X 41.18" Array:10'3%Z"X 6'10 3/8" Surface.21'3"X 10'9" Magic#:Invisimount Legend: ® 4 SunPower 327W Panel ® SunPower Invisimount Rad • 12 Eco-Fasten Quik Feet BB 2x6"Douglas Fir Rafter 16"O C Notes: Number of Roof Layers. 1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: Cq� PSP�A c/F�C� o �O 06 61$2 AROFESS\ONP� Drawn By.MMB Drawing#11 of 17 Date-1/20/2017 REV:A Drawing Scale:3/16"= 1.0' rGREENLOGM ENERGY GreenLogic,LLC Approved Susan Honig 745 Wateredge Way Southold, NY 11971 Surface#D: Total System Size, 10.464kW Array Size 1.308kW 1 Circuit of 7 on a 20A Breaker(shared with S#E) Azimuth:214° Pitch:14° Monitoring System: Sun Power 5t— Panel/Array Specifications: Panel.SPR-E20-327-C-AC Racking Sun Power Invisimount Panel:61.39"X 41.18" Array 10'3'/s"X 6'10 3/8" Surface:21'3"X 10'9" 3 Magic#. Invisimount Legend: 4 Sun Power 327W Panel ® Sun Power Invisimount Rail 3 • 12 Eco-Fasten Quik Feet 8 2x6"Douglas Fir Rafter 16"O C. Notes- Number of Roof Layers. 1 Height above Roof Surface.4" Materials Used:Eco-Fasten,Sun Power Added Roof load of PV System-3.5psf Engineer ' Ic,,t'Sea[: OF 0 &C( NCO 0661 Drawn By:MMB Drawing#.12•of-17 Date 1/20/2017 _ REV:A`"°' Drawing Scale:3/16"= 1 0' C ' L ENERGY Green Logia,LLC Approved Susan Honig 745 Wateredge Way Southold,NY 11971 Surface#E: Total System Size:10.464kW Array Size:3.720kW 1 Circuit of 7 on a 20A Breaker 1 Circuit of 7 on a 20A Breaker(shared with S#D) Azimuth:12.4° Pitch:14° Monitoring System: 2 SunPower Panel/Array Specifications: Panel:SPR-E20-327-C-AC Racking.SunPower Invisimount Panel:61.39"X 41.18" Array:15'5 5/8"X 13'8 34" Surface. Magic#.Invisimount Legend: ® 10 SunPower 327W Panel ® SunPower Invisimount Rail • 28 Eco-Fasten Quik Feet H2x6"Douglas Fir Rafter 16"O.C. N otes: Number of Roof Layers 1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: SOF NEVV k 0 I W •Il 1ICRG V V�Q 066116 AR�FESS\o�p�, Drawn By-MMB Drawing#13 of"17 Date. 1/20/2017 REV.A Drawing Scale:3/16"= 1.0' L' P O ENERGY Green Logic,LLC Approved Susan Honig 745 Wateredge Way Southold,NY 11971 Surface#E: Total System Size- 10.464kW Array Size-3 720kW 1 Circuit of 7 on a 20A Breaker 1 Circuit of 7 on a 20A Breaker(shared with S#D) Azimuth:124° Pitch. 14° Monitoring System 2 Sun Power Panel/Array Specifications: Panel:SPR-E20-327-C-AC Racking:Sun Power Invisimount Panel 61.39"X 41.18" Array:15'5 5/8"X 13'8 Y4" Surface.37'1"X 16'6" Magic#:Invisimount Legend: ® 10 Sun Power 327W Panel ® Sun Power Invisimount Rad • 28 Eco-Fasten Quik Feet B2x6"Douglas Fir Rafter 16"O.0 Notes. Number of Roof Layers. 1 Height above Roof Surface 4" Materials Used Eco-Fasten,Sun Power Added Roof load of PV System*3 5psf Engineer/Architect Seal: ®F NEw y' CO 0 n �O 66 61$2 AR�FESSIo Drawn By:MMB FDra�wing#14 of 17 Date.1/20/2017 A,_a ` Drawing Scale:3/16"= 1 0' GREEINLOGME) ENERGY GreenLogic,LLC Approved Susan Honig 745 Wateredge Way Southold,NY 11971 Surface#E: Total System Size- 10.464kW Array Size:3 720kW 1 Circuit of 7 on a 20A Breaker 1 Circuit of 7 on a 20A Breaker(shared with S#D) Azimuth. 124° Pitch. 14° Monitoring System: 2 SunPower Panel/Array Specifications: Panel.SPR-E20-327-C-AC 4 Racking-SunPower Invisimount Panel:61.39"X 41 18" Array. 15'5 5/8"X 13'8 Surface.37'1"X 16'6" Magic#:Invisimount 4 Legend: ® 10 SunPower 327W Panel ® SunPower Invisimount Rail Is 28 Eco-Fasten Quik Feet 4 3 B� 2x6"Douglas Fir Rafter 16"O C Notes Number of Roof Layers- 1 3 Height above Roof Surface.4" Materials Used Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer t Seal: ofEW) PA - r✓7F � O i �O 066182 A��FESS10��� Drawn By- MMB Drawing#15 of 17 Date 1/20/2017 REV:9 Drawing Scale:3/16"=1.0' No Vent Pipes Will Be Covered By The Solar Array GREENLO(MC ENERGY Green Logic,LLC Approved Susan Honig 745 Wateredge Way LEGEND: Southold,NY 11971 AR Access Roof per R202 Definitions Total System Size:10.464kW GA Ground access area per R324 7 3 width to be the same as AP as measured at eave Array Size:3.720kW RAP Roof Access Point,to be away from overhead obstructions,doors,windows,decks,fences and landscaping 1 Circuit of 7 on a 20A Breaker AP Access Pathway 36"Minimum width per R324 7 4 and R324 7 5 RWV Roof with valley 18"minimum from valley 1 Circuit of 7 on a 20A Breaker SVO Smoke vent operation per R324 7 7 18"minimum from ridge - 1 Circuit of 6 on a 20A Breaker 1 Circuit of 12 on a 20A Breaker Azimuth:124° Pitch-14° Monitoring System- SunPower 10 SunPower 327W AC 3 SunPower 327W AC Panel/Array Specifications: 6 SunPower 327W AC Panel-SPR-E20-327-C-AC Panels Panels Panels Racking:SunPower Invisimount Panel:61 39"X 41.18" Array: 15'5 5/8"X 13'8 W Surface.37'1"X 16'6" Magic#: Invisimount Legend: AR AR f ® 32 SunPower 327W Panel SunPower Invisimount Rail _ •------------- • 92 Eco-Fasten Quik Feet � ____ SVO H 2x6"Douglas Fir Rafter 16"O.C. --------------------------- -- N otes SVO x V Number of Roof Layers: 1 sVo ________________ Height above Roof Surface 4" Materials Used Eco-Fasten,SunPower AR Added.Roof load of PV System.3.5psf Engine Seal: k- NEW �,PN PA o, 'A I I IlnfnI - AL O01 I < � , I 4 SunPower x I �O 06618 327WAC i 9 SunPower 327W AC AS10��` - I - Panels , Drawn By- MMB Drawing#16 of 17 Meter Date:1/20/2017 REV.d' Drawing Scale-3/32"= 1 0' GREENLOGICO ENERGY Green Logic,LLC Approved Susan Honig 745 Wateredge Way Southold, NY 11971 Total System Size:10.464kW Array Size-3 720kW 1 Circuit of 7 on a 20A Breaker 1 Circuit of 7 on a 20A Breaker 1 Circuit of 6 on a 20A Breaker 1 Circuit of 12 on a 20A Breaker - -- - -------------- - - ------- --- ---- --- - T ---, - - --- - Azimuth- 124° Material List Rall Material List qtY j -- T — Pitch. 14° ( MonitoringSystem: 2 -- --�----- ---- ----- - ----------- ------- Sun Power i --- ----- ---- --- --- -- - i- ---- -- - - — --- --- - -�--- -- -- Panel/Array Specifications: ---------- ----- - - ----- - Eco-Fasten Quick Foot Base Plate 92 _ _ „ — Panel:SPR-E20-327-C-AC - I i Rackin •Sun Power Invisimount Eco-Fasten Quick Foot Square Aluminum Block - I 92 g — -- -- -r-- - -- - --- - - Panel:61.39"X 41.18" Eco Fasten Quick Foot Flashing 92 Arra :15'5 5/8"x 13'8 -------------ate --------- -------- ---- -- - - - --- - -- -- ---- -- - --- - ---,-- - --- ---'--- --- - y #14-13x4,5"DPI Concealer Screw i184I Surface:37"1"x 16'6" - -- -- ----;- ------ --- - ---- -- -;---- -- ----- --- a-- -- - - -`- - -- - Magic#- Invisimount --�--- - --r-- -- -- - - ---- Legend: 2 Sun Power 327W Panel Sun Power Invisimount Rad 92 Eco-Fasten Quik Feet G 2x6"Douglas Fir Rafter 16"O C. i -- --- - -- - -- --- - -- -I — -- - --------- - —-- ----- - -- - - - - -- - - - -- -- � C( Notes. __-- --- _ ------ - --.----f_---__---___-- Number of Roof Layers: 1 j I ( Height above Roof Surface-4" - - - - -- - - ---- ---- -- --- - - -- j ------;--- j i - - -- ----- -- -- Materials Used-Eco-Fasten,SunPower - - - - --- - ----!- --i--— -------- - ( i --- -- Added Roof load of PV System:3.5psf --- - ---- --a- ---I -------�--- ----- �- - --- --- - - i-- ---- ---- Engineer/Architect Seal: ---------- ------ CO W - Lll i �O 066 A��FESSO" - Drawn By:MMB Drawing#17 of 17 Date-1/20/2017 REV-A., Drawing Scale:3/32"= 1.0' 7 Y: N A Design-Driven Advan-,ages #1 modile:,esti-etics and efficiency Ji-matoned mod Ile rel ab l,ty2 SERIES No ci(..c*ro'y`is CaPaCILOr-3 25;,ear Combined Pow,_-,and Prccuct 'v1'-.,;rranty Maximize Value for Roof Sl7e system for roof,not string-we,-Ler Expand Deployment,Options Small systems ( ,stere expandab F.,Y Simplify&Speed Installation OpUrnize System and Installation Efficiency Factory-qt6arated microinverter SLjn,)wver'*)AC N.,lodules,,vvhich irclucie a f or,',_lr,'egra,[ed RObd,t,CICL.'alp-lockin1c,Alk"connectors - Des,gn floxibility oflsitean'O OnSKC SirPckt,,,er micro we-ter,provide a revol,i-ionary rornbinatior o"n gh No DC string sizirg process Pffcien(y,high ref nbik ,and povver ronve.—ion Fewer nsrallazibn steps-,,-)an competirg Des-gred speofically for with Sul lrvisiMoUrtl and the systems Component of Compete Sysrem ris`aliauon,nest-'-, class system aesthetics,and int-i tive vsibil,ty,nm B',Iilt-'OrL,Fe�,,,,znSt,nPowe,'�lir,,v,,itVct�ritl", systei-Perfor-iar-ce All-his r.,cr-es wi-,l-,the nest Combined Pulver aric tFe`ViPower Monitoring Slystern and Pro d,jct'A1ar,ant,,, St,pei io,sys!en, rellab i lity ancl'c;(_'SL1[`CLlcS sunpower.com N 13 hoil: V ell N WR, '4' SDR-E20-327-C-AC SPF—Z E19-32&C-AC Solar Cells 96 IM011COYSLalli-e Maxec--'�Even !`,oininal Pov,.,Pr-(P--rn) 927 W 320 w Higin-transm;ssion tomperca glass vv&anzi- i, Povvor-clerance -Sr- IYO. _5/-09/3 rnil Gless ef lir-cvve coating Avg Pane ;Efficiencyl 2u4% 19 90� Env rownertal Outdoo-rate-, Temp --re*, (P'uwef) 0 3SCAF 11 Fwrw Class I ;--.la,,kanodizod NNAIA ,it ir- "I'ec,bypass dlod'2s --iacle Tolerar ce -]-,to,rutec mOCILk'CV,'l 1-.';-'XIMiim pcv,-cr Vveig,)t 45 5 lbs f20 6kg) ------------------ point ------ punt rdt-kir,p, Max Reccinmencled 1 3 ir- (33 mrn) l Spacir,g —---------------------------- Oi-tp,t(��.240 V,"r-m ir:orr I'max) 2, /240/264V OLtP-A Oc, 183,208/229 V Operit4-i.q--requency(m,-i..'rom./max 1 59 3160 0/60 -Az Wa'rar-IL'es 25-year I'mited-,�o*cr wa-anty 0i.tp!A Po;,r Factor(m n, 099 25;gear I i-nived prodictwam,iy a AC Max Coin -,n,joi, OUtPU-�:U'1`01­1' 240V 3?A LA 17,'1,ir,,lud ng ornpl-j•ic-,wid- AC Max C-01 U."IJOI.-OULPU,Curreri, 208 V 5/,A 3Dp I i ca Die rec u i m-,c rts of IEEE 1547 a n a ACM / Cori, W,pi. I lo'vve i 320 W lEtL 15A7.1 DUAC CLC Conversion Efficiency 96 045 KC a-,.j ICES-ID,03 C!as,-B Max Jn'ts Per 20 A Branch Circuli. 2--3'V' 12(single pnasc) AC m-,,du:e Type'I Fi,e Rate d 14-ix Un is Per 20 A, Bram-h(-I'(Ult @1 208V Hu(Iwo Pole) UL 2703 UsLed'o,,hen InvisiMoun"'I Class A FIrE Rated when to 224 listance tei.Weer) P" 1. InvisilvIozit 11 a-d ovhen a - Operaung-ernip --/C'7'o 185'F 40*C to '-85'r; roofs-i-face and DOILLO"T Cf SunPower Mlax Amciei,,t Ter-p 12"l-(50"CI r-T-oduk-frame v;-9,5"(S 39 mill -------------- ------ Wi-id F'2',s- 3000 Pa,305 kc/-r,2 4,Gnt&',,aCk Alterrar ni-,Current(AC)Modik aes,'-naticr Mlax -oac Snow: 12S Ds`6000 Pa,611 k�:rn-'�r•ort enables installaw,-in accordaize v:'&NIEC 'I i-)ch(25 rrimn)diaiiete-hail at 52 rriNl-',23 690 E) m.,s, DID Tos, Potertial-nduccc,de[radatni- rct, [1'^2.nj 1107 Mm 'nj 30 mm 1, r pw- vi,,,'j Pet) 14 1411 rank n PYMcid,ile rt'rblty r U:t,e rLN'J'IC F,veo�,t of the C ,ta,oa d Test Co-;tlo,,s(1 AA.1 5,2-,'C)'qPE-c,,Iuralor s,,rdorl z0r,'5 r.'n-I.N -a-aAJI)f w11 hl-tp('111','IL I? Please read tre safety and instal anon nsmct ors fcr details StIVAIA'V,unpw,& ro-,"3-,•vr w,ry-,fe,enoq',,,in3t,on C J ore Beta s-exle,,"."Ijitvsl ee.'%WASur no. cc ri t Docuei t 51521,7 Rev FZ-,', 'A, 2.MW 75 Simple and Fast Installat'on If tegraied module-to-raii'grouric ng P-e-asspmHeo mid a-id erd' -lam.-,-, Levitating 11id c:a,-gyp fcr easy placement ,,'. I id cla- inowidth'clitateseven ,n oou le,spacj rig simple, pre-dr Iled rail splice UL 2703 Listed iitegrateu grounriVa Flex,.ole Design Ao&esses nearly all slopes resicleriti@l ooff, Design 1'i landscape and po,trai, Rails P,,Iable ea-,,,obstacle mahagemer-r. N Custom,er-Preferred Aesthetics module ana;j­l mounting aesthetics Best-in-class systeni aesthetics Elegan-,Simplicity Prcmiurn,low-ProRe desigr B' ;acJ Sunllowerl�) IrIVISIMOUnt" is a Sunl1ower-clesigneci ,<aricdized components Flidder-mid clamps and end clamps rail-based rrounung systern. The InvisMount system hardware,anc.capped,flish rails addresses res clential slor)ed roofs and Combines faster" Part of Superior System installation time, design flexibility, end superior aesthetics, Z-1 Bull, for use with Sur,Powen DC and AC:Yio,'iules The InvisiMount prcCUCt was specifically env,sioned and Combi r.e lmth Su-)Power modiles and engineerea to oa:r vith SunPokfver i-nooules.T-e resulting mor-,tor ng,ap j sysrem-level approach w;l1 amplify-,he aesthetic ane, installation benefits for bot— homeowners and installers. sunpower.com q V., 4, .7 -7 ­7 M'. M MOU,1,1ek 1 mj(j Clamp and pall Module i End Ct,,,r,o and Rail Mid Clamp En:1 Oamp Rail Pa,Coltce C-roki:-jj L t,2 As-,ernbly f rid Tempe•)tl_r(? _­C'C to 90'C' to 19"R comoof,ent IVater,al Ive OrIt Max I oxi i ,ZOO Pa k1olift �,AdClarr,p Filac,(,vide:rainless srcL AISI 30L 63 ( )2 2 o. Pa r"),""l-force End Clarl­-_ Blar anoatz--d alu-n--m alloy 60631'E, 110908904) Rad Blau inoctz(_,,j alurril _malloy 5-0()5-76 830 g/rn(9 ozr,,) -Rall SOce ALminum alio;600`5--5 830 VIn(c,--ft) I ,ear prco-jct Aarrant,v ;-year finist viarran-.y �,),,_nd 1-9 304 , stp,nlesc 1 s, (t,2-70!)OIL,tin-plated ccppet lug) End CGp 31arkacetal,'�010),,-r)poyr-icr If,4 g(0 37 oz) X 2703 Lis ed Cer*iftcattons I •lass A fire-at,,-.,ovvIIeq clistance n2t-,A.,2cn i 0ooT surfar,�,and DO TOM of Si.,nP-),,vcr A M i nodulim rame is 3'"1 4m, Cornpwioow Yv gle R,,)ftef Attarnment kplicat 0- Compos,-,,o,Si.rele Roof Deckin,g Atlach-irri Curved and Flal.Tile Roof Attac-rTcril, Univeral In'Pi face for0trier Roc{Atiachr iP^Cs Rerer Lc roof attF chi nei it I doctime--anon omooul(-fr4'T'e that 15 compatible www.zria ell"cii liard'viire imerapelatil 1,'J '2C' S,jnP, ower Corv,Frion,Ali Rigms the StJ,4FO,.4FR 1,-),-c,Z,c, UNT arc trsde­arxs ur'eFISL ?i fill o,heitiademarhs are the Sul'120"U.-r COM 51)sJT,3,ef S 1-cludezi -,this "Ire"',ect'.cl),-gl--v"Ithout I-OtICE. Dr)c TIPJt1k5r')506Rev i.-3 '!4 -5 t n Suffolk Cou 'ty Executive-s 0 ce o Consumer Affairs VETERANS MEMORIAL HIGHWAY HAUPPAUGE,NEWYORK 11788 0* DATE ISSUED: 5/25/2006 No. 40227-H SUFFOLK COUNTY R ZU.--i, ilume Improvement Contractor License V'" This is to certifv that MARC A CLEJAN doing business as GREEN LOGIC LLC having furnished the requirements set forth in accordance with and subject to the provisions of applicable laws,rules and regulations of the County of Suffolk,State of New York is hereby licensed to conduct business as a HOME IMPROVEMENT CONTRACTOR,in the County of Suffolk. Additional Businesses NOT VALID WITUOUT DIEPARTMENTAL SEAL ANDACURRENT CONSIJI�AEJt AFTAIR.S ID CARD q- Director 5111� 0, CERTIFICATE OF LIABILITY INSURANCEDATE(MM/DDNYYY) 101/30/2017 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Brookhaven Agency,Inc. Brookhaven Agency,Inc. PHONE 631 941-4113 FAx 631 941-4405 128 Old Town Road Suite C EMAIL brookhaven.a enc verizon.net PO Box 850 PRODUCER East Setauket NY 11733 INSURERS AFFORDING COVERAGE NAIC# INSURED INSURERA: HDI Global Insurance Co. Greenlogic,LLC INSURER B: Merchants Preferred Insurance Co. 425 County Road 39A,Suite 202 INSURER C- First Rehab Life Insurance Co. Southampton,NY 11968 INSURER D: Endurance American Insurance Co. INSURER E: AGCS Marine Insurance Co. INSURERF: National Liability 8r Fire Insurance Co. COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE'FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDLLTR TYPE OF INSURANCE INSR mn SUER POLICY NUMBER POLICY EFF POLICY EXP LIMITS GENERAL LIABILITY EACH OCCURRENCE $1,000,000 A [X: COMMERCIAL GENERAL LIABILITY X X EGGCR000076917 01/31/17 01131118 DAMAGE TO RENTED $100,000 CLAIMS-MADE �OCCUR MED EXP An one erson $5,000 XCU PERSONAL&ADV INJURY $1,000,000 X Contractual Liab GENERAL AGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER PRODUCTS-COMP/OP AGG $2,000,000 POLICY FX PRO LOC $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT (Ea accident) $1,000,000 B X ANY AUTO CAPI043565 8/11116 8111/17 BODILY INJURY(Per person) $ ALL OWNED AUTOS BODILY INJURY(Per accident) $ SCHEDULED AUTOS PROPERTY DAMAGE $ X HIRED AUTOS (Per accident) X NON-OWNED AUTOS $ X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $1,000,000 D EXCESS LIAB CLAIMS-MADE EXC30000250900 1/31/17 1131/18 AGGREGATE $1,000,000 DEDUCTIBLE $ RETENTION 0 $ WORKERS COMPENSATION X I WC STATU- OTH- AND EMPLOYERS'LIABILITY F ANY PROPRIETOR/PARTNERIEXECUTIV�L NIA A V9WC794777 6115116 6/15/17 E L EACH ACCIDENT $1,000,0110 OFFICERIMEMBER EXCLUDED? J (Mandatory in NH) E L DISEASE-EA EMPLOYEE $1,000,000 If yes,descnbe under DESCRIPTION OF OPERATIONS below I _ E L DISEASE-POLICY LIMIT $1,DOD,000 C NYS Disability D251202 4/11/16 4/11117 Statutory Limits E Installation Floater/Property MX193071832 4/15116 4/15/17 $500,000 $1,000 Ded DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additional Remarks Schedule,if more space is required) CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE <NSZ> ©1988-2009 ACORD CORPORATION. All rights reserved. ACORD 25(2009109) The ACORD name and logo are registered marks of ACORD STATE OF NEW YORK WORKERS'COMPENSATION BOARD CERTIFICATE OF NYS WORKERS' COMPENSATION INSURANCE COVERAGE Ia.Legal Name&Address of Insured(Use street address only) lb.Business Telephone Number of Insured Greenlogic LLC 631-771-5152 425 County Rd 39A Ste 202 lc.NYS Unemployment Insurance Employer Southampton NY 11968 Registration Number of Insured Id.Federal Employer Identification Number of Insured Work Location of Insured(Only required f coverage is or Social Security Number specifically limited to certain locations/it New York State,I e.,a 203801194 Wrap-Up Policy) 2.Name and Address of the Entity Requesting Proof of 3a. Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) National Liability&Fire Insurance Company Town Of Southold 3b.Policy Number of entity listed in box"la" Building Department V9WC794777 53095 Route 25 3c. Policy effective period Southold,NY 11971 06/15/16 to 06/15/2017 3d. The Proprietor,Partners or Executive Officers are included. (Only check box if all partners/ofticers included) X all excluded or certainpartners/officers excluded. This certifies that the insurance carrier indicated above in box "3" insures the business referenced above in box "1a" for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"T'. The Insurance Carrier will also notithe above certificate holder within 10 days IF a policy is canceled due to nonpayment ofpremiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices maybe sent by regular mail.) Otherwise,this Certricate is valid for one year after this form Is approved by the insurance carrier or Its licensed agent,or until the pollcy expiration date listed in box 113c",whichever is earlier. Please Note: Upon the cancellation of the workers' compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by:NICHOLAS ZULKOFSKE (Print n of authorized representative or licensed agent of insurance carrier) Approved by: Ma 23 2016 (Date) Title: Authorized Agent Telephone Number of authorized representative or licensed agent of insurance carrier: 631-9414113 Please Note. Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2(9-07) www.wcb.state.ny.us Workers' Compensation Law �,�/ �`' \ 714 ` :�,�-`d .i,;3;` � '••: r � � ��"` 7t..q v.''. e �'+�� `'�Fa�' cL`� ��.. � '�'1l +Ijc: i fh. •i i y t e� Suffolk County VETERANS MEMORIAL HIGHWAY HAUPPAUGE,NEWYORK 11788 f y f: DATE ISSUED: 12/1012007 No. 43858-ME -'i fl. SUFFOLK Master Electrician License . This is to certify that ROBERT J SKYPALA r doing business as GREENLOGIC LLC h vi factory evidence of competency,is hereby licensed as MASTER ELECTRICIAN in accordance a ng given satis with and subject to the provisions of applicable laws,rules and regulations of the County of Suffolk, State of New York. rl - 1 Additional jkl GNOT VALID WITHOUT =' � hl `4� DEPARTMENTAL SEAL 1 . CONSUMERND S CURRENT 11) 1 Director 111 } AQ r ti } 'i. y .���.,_ ,• t ., .t��-' ....a /. .x�� `�,' ,. '" , ,mfr`��• `•, ¢ °Z �3'G •`S- ... "-.s ��+-� !�' a'`.;y: i�.+ �`. �', 1.��'.,.-h... G..Y n'.� `� \c.•Y"�L _ v� .ice i t'. �3 i`� v - ! ��.�-S`a`J�'I•. t �;.%'`ltri I'1\ NF-s NEW EQUIPMENT—___e....___._....__—__ EXISTING SERVICE PV–SA--1 > A AC–COMBINER PANEL 120/240, 1PH, 3W AC–CMB-1 B • • • 1 (PV LOADS ONLY) 200A l{11-I I PV–SA-2 -CA . . . _1211f— A B N I C {� • • I alta-1 AC–CSC-1 , - r AC DISCONNECT I II I ' PV–SA-3 0 i i BKR-2 FM . .. • • • 2 1 L BKR-3 _ ---�MAIN BKR-d s A B N PV–SA-4 i i FUSED j ® I N Irj GC TYPICAL PV MODULE WITH III I INTEGRAL DC/AC INVERTER IIII ECC I IIII I � 9—ca IIII I I IIII I � I I IIII I I EXISTING AC PANO[EXISTING C I I LL.�1._....—_.--_.._---_...—.i...—._ --..—__.,—._....--._—.---_ — _ GEC 6 cu PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Honig, Susan Np , 745 Watersedge Way Southold, NY 11971 ENERGY ELIMINATING THE COST CE ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: Honig-3LD1 Revision: 1 Revised: 1/18/17 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327-C-AC, 1-CIRCUIT OF 6-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327-C-AC, 1-CIRCUIT OF 9-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327-C-AC, 1-CIRCUIT OF 7-MODULES PV-SA-4 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327-C-AC, 1-CIRCUIT OF 10-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 1962 WATTS 211-264 VAC 7.98 A AC 240 V,AC PV-SA-2 2943WATTS 211-264 VAC 11.96 A AC 240 V,AC PV-SA-3 2289 WATTS 211-264 VAC 9.30 A AC 240 V, AC PV-SA-4 3270 WATTS 211-264 VAC 13.29 A AC 240 V, AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Honig, Susan G a E E N LOG I Co 745 Watersedge Way Southold, NY 11971 ENLRGY ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 3 Drawing No: Honi -3LD1 Revision: 1 Revised: 1/18/17 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMBP AC COMBINER PANEL 250V, 200A, NEMA-1, 1-PH, 3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-4 CIRCUIT BREAKER, PV-SA-4 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 60A, NEMA-1, FUSED; FUSE RATING: 60A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 2" PVC-40 4 / 6 C THWN-2 2" EMT 4 / 6 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUIT TO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE RE- QUIREMENTS. 4.) NOTE:GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER. - PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Honig, Susan 745 Watersedge Way ENERGY Southold, NY 11971 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: Honig-3LD1 Revision: 1 Revised: 1/18/17 EQUIPMENT—__—_--____...__ EXISTING SERVICE PV-SA-1 A AC-COMBINER PANEL 120/240, 1PH, 3 FmT,• • AC-CMB-1 ` i (�E • • • 1 (PV LOADS ONLY) 200A ISH PV-SA-2 AC-DSC-1 / N 1 I i BItR-,__ AC DISCONNECT ° SKR-a ' PV-SA-3FrL_ A I i . . . i • • • `� BKR-3 MAIN o II ) i A B N BKR-4 , PV-SA-4 A ° i FUSED ( s fu g {[ ♦ • • i t N ® 1 IEGC TYPICAL PV MODULE WITH INTEGRAL DC/AC INVERTER t i l l 4 EGC I i EGC r I j l j I i EXISTING AC PANPLEXI TING I GEC LL.11.. __ ______.L_— ..__....--_____..,..__ 1_ _ GEC __..._.____ PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Honig, Susana, `° 745 Watersedge Way .. " ENERGY Southold, NY 11971 ELIMINATING THE COST GF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: Honig-3LD1 Revision: 1 Revised: 1/18/17 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327-C-AC, 1-CIRCUIT OF 6-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327-C-AC, 1-CIRCUIT OF 9-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327-C-AC, 1-CIRCUIT OF 7-MODULES PV-SA-4 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327-C-AC, 1-CIRCUIT OF 10-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 1962 WATTS 211-264 VAC 7.98 A AC 240 V,AC PV-SA-2 2943WATTS 211-264 VAC 11.96 A AC 240 V, AC PV-SA-3 2289 WATTS 211-264 VAC 9.30 A AC 240 V,AC PV-SA-4 3270 WATTS 211-264 VAC 13.29 A AC 240 V, AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Honig, Susan i. REENLOGIC0 745 Watersedge Way E1=ICY Southold, NY 11971 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 3 Drawing No: Honi -3LD1 Revision: 1 Revised: 1/18/17 yM EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMBP AC COMBINER PANEL 25OV, 200A, NEMA-1, 1-PH, 3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-4 CIRCUIT BREAKER, PV-SA-4 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 60A, NEMA-1, FUSED; FUSE RATING: 60A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 2" PVC-40 4 / 6 C THWN-2 2" EMT 4 / 6 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUITTO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE RE- QUIREMENTS. 4.) NOTE:GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Honig, SusanE � � _ 745 Watersedge Way i - Southold, NY 11971 E ER 1Y ELIC 1NATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: Honig-3LD1 Revision: 1 Revised: 1/18/17