Loading...
HomeMy WebLinkAbout40786-Z FOj'real Town of Southold 9/21/2017 0 P.O.Box 1179 d' A 53095 Main Rd o4,,� Q�� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39234 Date: 9/21/2017 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 7132 Indian Neck Ln,Peconic SCTM#: 473889 Sec/Block/Lot: 86.-7-8 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/10/2016 pursuant to which Building Permit No. 40786 dated 6/21/2016 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Mitchell, Stephen of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40786 08-15-2017 PLUMBERS CERTIFICATION DATED Authorized Signature o�S�F of c�,co TOWN OF SOUTHOLD BUILDING DEPARTMENT y a TOWN CLERK'S OFFICE o . SOUTHOLD NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40786 Date: 6/21/2016 Permission is hereby granted to: Mitchell, Stephen 1061 Briar Ln Pottstown, PA 19464 To: install roof-mounted solar panels as applied for. At premises located at: 7132 Indian Neck Ln, Peconic SCTM # 473889 Sec/Block/Lot# 86.-7-8 Pursuant to application dated 6/10/2016 and approved by the Building Inspector. To expire on 12/21/2017. Fees: SOLAR'PANELS $50.00 CO -ALTERATION TO DWELLING $50.00 LECTRIC $100.00 Total: $200.00 ilding Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957)non-conforming uses, or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. 6/6/16 New Construction: x Old or Pre-existing Building: (check one) Location of Property: 1732 Indian Neck Road,Peconic,NY 11958 House No. Street Hamlet Owner or Owners of Property: Stephen and Stephanie Mitchell Suffolk County Tax Map No 1000, Section 86 Block 7 Lot 8 Subdivision Filed Map. Lot: Permit No. 7 (D Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ 50•oD ,,pplicant Signature pf SOUTH®�® Town Hall Annex Telephone(631)765-1802 54375 Main Road y Fax(631)765-9502 P.O.Box 1179 ® �� roger.richert(aitown.southold.ny.us Southold,NY 11971-0959c®U6� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Mitchell Address: 7132 Indian Neck Road city,Peconic st: New York zip: 11958 Building Permit#: 4.0786 Section: 86 Block: 7 Lot: 8 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Green Logic License No: 43858-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures �] TVSS Other Equipment: 19.430 KW Roof Mounted Photovoltaic System to Include 58- SP 335 W Panels with Micro Inverters. Notes: Inspector Signature: Date: August 15, 2017 0-Cert Electrical Compliance Form.xls Pacifico Engineering PC _ Engineering Consulting 700 Lakeland Ave, Suite 2B �' C s. Ph: 631-988-0000 Bohemia, NY 11716GIN - R GP Fax: 631-382-8236 www.pacificoengineering.com --� -- solar@pacificoengineering.com July 10, 2017IV Town of Southold (' u v l� D Building Department 54375 Route 25, P.O. Box 1179 AUG 7 201 Southold, NY 11971 Subject: Solar Energy Installation for B ,D1NG� ' Stephen MitchellT® Og SO�OLD Section: 86 7132 Indian Neck Lane Block: 7 Peconic, NY 11958 Lot: 8 1 have reviewed the solar energy system installation at the subject address on July 10, 2017.The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2010 NYS Building Code, and ASCE7-05. To my best belief and knowledge, the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice, with the view to the safeguarding of life, health, property and public welfare. Regards, Ralph Pacifico, PE Professional Engineer of NEwY PAc�,��c�o,A • r i 2 066162 4i Ralph A9 � NP\ngineer NY 0661 04744306 FIELD 7I�SPE ON P- MVO T DAA Co�rr�� FOUNDS loo (2N1b) ROUGH FR��C� PLUMBING " INSULATION PER N.Y. STATE ENERGY CIODE FINAL J o ' d TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX:(631)765-9502 Survey. SoutholdTown.NorthFork.net PERMIT NOCheck Septic Form N Y.S.D.E C Trustees C.O.Application Flood Permit Examined 120 Single&Separate Storm-Water Assessment Form Contact: Approved 20jy Mail to: Disapproved a/c Phone. Expiration 20 D [EC[E0'V[2 Building Inspector DD APPLICATION FOR BUILDING PERMIT JUN '} 0 ""161Date 4/19 20 16 INSTRUCTIONS BITMDINGDMtion MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 70w $ ug �tplan to scale.Fee according to schedule. lot p an s owing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signa a of applicant or name,if a corporation) 425 County Road 39A, Southampton, NY 11968 (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder General contractor Name of owner of premises Stephen and Stephanie Mitchell (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 40227H 1. Location of land on which proposed work will be done: 7132 Indian Neck Road, Peconic, NY 11958 House Number Street Hamlet County Tax Map No. 1000 Section 86 Block 7 Lot 8 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction- a. Existing use and occupancy Single family dwelling b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work Roof mounted so ar it nstaflation 4. Estimated Cost $97,044 Fee 200.00 (Description) (To be paid on filing this application) 5. If dwelling,number of dwelling units 1 Number of dwelling units on each floor If garage, number of cars 6. if business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase 5/30/97 Name of Former Owner Nina Sittler Fischer 11 Zone or use district in which premises are situated 12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO X 13.Will lot be re-graded?YES_NO X Will excess fill be removed from premises9 YES_NO X Stephen&Stephanie Mitchell 1061 Blair Lane,Pottstown,PA 19464 14.Names of Owner of premises Address Phone No. Name of Architect Address Phone No Name of Contractor GreenLogic LLC Address 425 Cty Rd 39a,SH Phone No. 631-771-5152 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES x NO *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland9*YES x NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO x *IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF suffolk) Nesim Albukrek being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application, that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Swom to before me this CO day of 201(, l sNO Signature of Applicant ANNET-E CAPURS01 q i+lotsry?public,State of Nee 4j -No.01 CA6293189 Qualified in Suffolk COunfy Commission Expires Se tember 03,2017 Scott A. Russell ,� 0S111FQ Ir 5T01KMWAT1E1k SUPERVISOR 5? � ( r � I��l[A1�A\G]EI��1[]El�T SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 Town of Southold CHAPTER 236 - ST®RMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) I! —DOES THIS _PROJECT M INVOLVE ANY OF THE FOLLOWING: I! (CHECK ALL THAT APPLY) Ii Yes No ❑Q A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. p ❑® B. Excavation or filling involving more than 200 cubic yards of material �i within any parcel or any contiguous area. ❑❑ C. Site preparation on slopes which exceed 10 feet vertical rise to ;! 100 feet of horizontal distance. I ❑® D. Site preparation within 100 feet of wetlands, beach, bluff or coastal { !} erosion hazard area. ❑a E. Site preparation within the one-hundred-year f loodplain as depicted on FIRM Map of any watercourse. t} ®❑ F. Installation of new or resurfaced impervious surfaces of 1,000 square j feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes I If in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. }� APPLICANT- (Property Owner.Design Ptofesstonal.Agent,Contractor.Other) r S.C.T.M. 1000 Date Dwrict 1i NAtis• Nesim Albukrek 86 7 8 6/6/16 Scclton Block Lot FOR BUILDING DEN RTMENT USE ONLYP—**`* ' Contact Information. 631-771-5152 ! 1 j I l�.`P &'L�C'� RevteweReviewedBv: _ - 4- - - - - - - - - - - - - - - - - ,I IDate: !i Property Address/ Location of Construction Work: — _ _ _ _ {{ ii ❑ Approved for processing Building Permit. I 7132 Indian Neck Road Stormwater Management Contiol Plan Not Required. i �� ® Stormwater Management Control Plan is Required. { (Forward to Engineering Department for Review.) FORM " SMCP-'FOS MAY 2014 /1 7 I /15P Town Hail Annex 4 Telephone(631)765-1802 54375 Main P.O.Box 1179 d y rocler.richert(c��own soUjf9Ao A. nv us Southold.NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: Company Name: GreenLogic LLC, Name: Robert-Skypala License No.: 43858-ME Address: 425 County Road 39A, Southampton, NY 11968 Phone No.: 631-771-5152 JOBSITE INFORMATION: (*Indicates required information) *Name: Stephen and Stephanie Mitchell *Adds: 7132 Indian Neck Road,Peconic,NY 11958 *Cross Street: Indian Neck Road *Phone No.: 631-921-5701 Permit No.: Tax Map District: 1000 Section: 86 Block: 7 Lot: *BRIEF DESCRIPTION OF WORK(Please Print Clearly) Roof mounted solar electric system (Please Circle All That Apply) *Isjob ready for inspection: YES 1 O Rough In Ina *Do you need a Temp Certificate: YES/ O Temp Information(If needed} *Service Size: 1 Phase ' 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form ��- New York State Department of Environmental Conservation Division of Environmental Permits, Region 1 SUNY @ Stony Brook 50 Circle Road, Stony Brook, NY 11790-3409 Phone: (631)444-0365 ® Fax: (631)444-0360 Website:www.dec.ny.gov TIDAL WETLAND LETTER OF NON-JURISDICTION June 15, 2011 Mr. Stephen Mitchell 7132 Indian Neck Lane Peconic, NY 11958 Re: UPA#1-4738-04043/00001 r raiiiy- - 132 ind•ari Neck Lane SVtiMA 000-uo---8 Peconic (Peconic Bay) Dear Mr. Mitchell: Based on the information you have submitted, the New York State Department of Environmental Conservation has determined that: The referenced property landward of a substantial man-made structure (concrete bulkhead) greater than 100 feet in length and constructed prior to 8/20/77, as evidenced on the survey prepared 'fey Roderick Van Tuyl dated 3/3/70 and shown on the plot plan prepared by Raymond Nemschick last revised 5/31/1.1, is beyond Article 25 (Tidal Wetland)jurisdiction. Therefore, in accordance with the current Tidal Wetlands Land Use Regulations (6NYCRR Part 661) no permit is required under the Tidal Wetlands Act. Please be advised, however, that no construction, sedimentation or disturbance of any kind may take place seaward of the tidal wetland jurisdictional boundary, as indicated above, without a permit. It is your responsibility to ensure that all necessary precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Tidal Wetlands jurisdiction which may result from your project. Such precautions mayinclude ii'alliali ing adequate work area be-.NJee otdal wetland)urisdictiona! boundary and your project (i.e. a 15' to 20' wide construction area) or erecting a temporary fence, barrier, or hay bale berm. Please be further advised that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies. Sincerely, Laura Scovazzo / Deputy Permit Administrator cc: R. ,Nemschick BOH-TW File 'Zi 6i TOWN ®F SOU�`H®LD - PROPE��'Y ;;",RECORD CAR® /JJ __ • SSG OWNER STREET / - VILLAGE DIST. - SUB. LOT fel �Ch� l 'TILL,(a h V9ce @r(-d pf�eG FORMER OWNER N E ACR-. S W TYPE OFF;BUILDING SEAS. VL. FARM COMM. CB. 'MICS. Mkt. Value � n RES.2- /d= I �> LAND IMP. TOTAL DATE REMARKS 3o Cl 6A 5—-(oc�(5 d 7t�, fl/C.,`7- F-0,9 ,v 1 `L o ll w-�5- 3 J v a 0 t`...1 L---x 6" 9�Tturs4--3(sI I/�S/l 21 ft z r T' "''n C4,e-sz., �'l k o rr � a a t� y'D !S ® ✓ ;�'. '/`? �1?t'�c�° lo�f�v� /x/7.3 0 d62A R,-,,-,P -3 50 b 7�2) 00 l a 1?&6 L311D'oc) 4500 , W 7510 AGE BUILDING CONDITION J (n/�,g1(&t� 40726 -1 NEW NORMAL BELOW ABOVE —� I FARM Acre Value Per Vciue Acre ' FRONTAGE ON WATER Tillable - � -' �-� - • _ ' Woodland Meadowl-and DEPTH - House Plot I BULKHEAD - Tota I� N., � �' DOCK r �; - ��SS■■■®■■�■� �■I■��.■■■■�!■■■■■■■ MM ■■!■■■■■■■■■■■Mai■■■■!■■■■■■■■■■■ ■■!■■■■■■■■■■■■SOME ■O■■■■Rooms 2nd Floor ■■ Rooms Ist Floor .L , Drivew ay AL. 3- \� 1 5 COLOR l JIM L v ok" ?� _ A � TRIMPell- 155;r oti 1 � J2 i 3 to 1 M. Bldg./jq ri, _ Foundation PO Bath rJ,,�y Dinette Extension x n..oci . �f 5;'+ Basement SLAB Floors Kit Extensio � WERT ..q Z��� Ext. Walls eS�IN6 Interior Finish L.R. Extension Fire Place Heat D.R I 14 E�-\114TvRvl Woodstove BR. I 3 Porch �( 13 ` (p5 Dormer `�` W* AM WD Attic (��M 4w%reeiew1-42 I X10 aLa�"`` i v/ Rooms 1st Floor S Driveway Rooms 2nd Floor Am (NI : O.B._ Pool a �tAcg C4� pP N GREENL®GIC® ENERGY June 6, 2016 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Dear Building Inspector: Please find attached a building permit application on behalf of Stephen Mitchell who has engaged us to install a roof mounted solar photovoltaic (PV) electric system for her home at 7132 Indian Neck Road, Peconic, NY 11958 In connection with this application, please find attached: • Building Permit application • A Storm Water Assessment Run-off Form • Certificate of Occupancy Application • 2 Surveys of the Premises • 4 Engineer's Reports (2 originals and 2 copies) • 2 One Line Electrical Schematics • 2 Spec. sheets of the solar panels • 2 Spec. sheets of the inverter • 2 Code Compliant Manuals for Racking System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$100 ($50 Building Permit/$50 CO) • Application for Electrical Inspection with a check for$100 Please let us know if you need anything else in connection with this application. urs truly, - Annette Capurso Office Manager GreenLogic LLC GREENLC 1 j!_ T5.j%rdLo.UI,Tom SOUTHAMPTON/CORPORATE SOUTHOLD MANORVILLE ROSLYN HEIGHTS 425 County Rd.39A,#101 52875 Main Rd, Box 435 40 Woodland Avenue 200 S.Service Rd ,#108 Southampton, NY 11968 Southold, NY 11971 Manorville, NY 11949 Rosyln Heights, NY 11577 Tel: 631.771.5152 Tel- 631.765 0404 Tel. 631 771.5152 Tel. 516.625.6880 Fax 631.771 5156 Fax. 631 771.5156 Fax 631 771 5156 Fax 516.625.6881 GREENLOGICO ENERGY D [EC[E0V[E DD July 31, 2017 AUG 7 2097 The Town of Southold BUILDING DEPT. Building Department TOWN OFSOUTHOLD t - 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Re: Building Permit No. 40786 Stephen Mitchell 7132 Indian Neck Ln, Peconic, NY To the Building Inspector: Enclosed please find the Engineer's Certification Letter and the Town of Southold Certificate of Compliance for Stephen Mitchell's solar electric system, which we installed at the above reference address. Please arrange to send him the Certificate of Occupancy and close out the building permit. Please let me know if you have any questions about the installation. Sincerely, Tamara Gajewskj Account Manager GreenLogic LLC 631-771-5152 Ext. 110 GREENLOGIC LLC o www.GreenLogic.com Tel. 877 7714330 Fax 877.771.4320 SOUTHAMPTON ROSLYN HEIGHTS 425 County Rd 39A 200 S Service Rd ,#108 Southampton, NY 11968 Rosyln Heights, NY 11577 r 7. TOWN OF SOUTHOLD PROPERTY RECORD-' CARD OWNER' STREET VILLAGE DIST. SUB. LOT L n C&r)J*e- ; 7 ()9 v/ FORMER OWNER N E ACR. S w TYPE OF BUILDING Z3 RES. 16' SEAS. VL. FARM COMM. CB. MICS. Mkt. Value 2- LAND IMP. TOTAL DATE REMARKS -2 'r �) / -/IW26, 7 7� 7- /0/,,, o C j 11 V-1 0 6 7 -pIt Cyt! l01F ell 73 5 71�1 2.. jLa6 epla , �dql To C, P.(,C C) I,- SZ)-37-L I I 934,pg- P-zc�e_r., 6 2 0 45-60 Od -1-4 f i(p 45- 3 15 k) 0?J -1 1(ee _J) 7!f .3 7.75 ,6 AGE BUILDING CONDITION v L; NEW NORMAL BELOW' ABOVE FARM Acre Value Per Value Acre Tillable FRONTAGE ON WATER Woodland Meadowland DEPTH House Plot BULKHEAD Total DOCK, r' ;•!•' COLOR a., s TRIM !, }o ` �t � '''.h3§�Yom''�+� �i.a,• r;� \ � _ rr� L� ...�"tel=''si.•> .a.. :�Li'c`�,,....,....:.,i;=�,`•z•_._ •` .. • s);L.nt'.;. .i'lv..... ::+ .. ------_-._- ._____----------_.__--86:7-8 3/2014 2Sr�d � M. Bldg. i` f "•ate ____ __ Extension,, y_z�• �' " � r..S� 7 Extension �, K .2-6 Extension' /t�,#� ,r `�'.-. ,to � a FoundationlJ� IBgfih .� ?� ,, Dinette Basement ''' �^ Floors _ Porch B .�. 9rL•t � 1<{� Porch Ext, Walls Interior Finish _ r LR, Breezeway 's Fire Place ., �, ` Heat TypeRoof `l r Rooms lsfi Floor BR. Recreation Room .. Rooms 2nd Floor FIN. B Dormer C��=� c`�' �� Driveway Total - I COLOR L V aQK, '2 10 1 TRIM a F r � (, 3 � , n i s+ An" Foundation e Bath � Dinette Extension /L FL-DtL 1_i 5�"`-� Basement � Floors Kit. W r� SLAB Extensio � +'1�f' _ Z��,� Ext. Walls G' iZ bVJN) Interior Finish L.R. Extension Fire Place Heat D.R. c` �1 / 2' ''atire-�up ��•1C� x I a y l� �,�.��idf�., V Woodstove BR. _ i. Dormer Porch 1J `f, L�Ff 51`(�N� ; 21bb Attic V/ 161 _ Breezeway I K Lo Gt 61rv1'rtG �9 a Rooms 1st Floor L V �4 X �� �i 1 Driveway Rooms 2nd Floor L�VIn "t O.B Pool �oeM 1 In�S��l/ / \ -� TE57 HOLE cf vicwrrY,w� / ` rraxrn BFLNYYLTY A�'\ A7� P.'e•�+ j{ww.V1 `f�;.,:Sl J 9; x b u I FPE rOYriDRM e ✓ �— STORMWATER RETENTION GALGULATIONS 163.65 / S238�4'30.E 195 98' a S26°42_50"E°<'- ,rff,awsr n mnx s� ji a r_ o ......... 5/TE DATA N23°44'30"Rr �°'."—1 ""� T— I, � ,§86.76' �rswwvartu uiu✓ ns I � R,d`f I I ra�mses, am "r II prnuxn Y �"� J UC cxxox ,� reg I �"(IYPnO�1 I �IT ,orMnan'ClmaaraaJHurmlYm,oRM}J MSAIBex6WP /1PL0T PLAN � rreamw�.er oq nx.,ro we 'rxw�. 0000® oq va,� / b � sr.uxra.ere w wr�v ^SANuTARYPROFILE �15EPTIG TANK rILEAGHING POOL �1DRYWELL DETAIL ,<..,, max. RP IPO WI N EMSCHICKSILV ERMANARCHITECTS P c P°�r�'^'� "nrcr •�.--^•p•� reru¢IL¢/oUKc IAYI3 u_m �--/`1>`--=- i 'a._ a_It— e01 rxrsar a(airY ncvo uww vs-arm "�' �•,e. PIP—1 Iaao acmx�n°« ',m 6 tl19 cu ReceiptCopy Page 3 of 3 SUFFOLK COUNTY DEPT OF LABOR, LICENSING & CONSUMER AFFAIRS PAYMENT RECEIPT RECEIPT NO. 314485 GREENLOGIC LLC 425 COUNTY ROAD 39A(SUITE 202) SOUTHAMPTON NY 11968 Rec'd From: D/B/A: Date: M CLEJAN GREENLOGIC LLC 04/06/2016 Payment Type: No: Drawn On: CHECK 12357 SUFFOLK COUNTY NATIONAL BANK Category Service Fee Violation Slip No ' Remarks 5-H.I. Contractor C-Lic. Renew. $400.00 ' SUFFOLK COUNTY DEPT OF LABOR. LICENSING&CONSUMER-AFFAIRS HOMEIMPROVEMENT ' CONTRACTOR LICENSEMARC A CLEJAN ''� \� eusaesscuxE .e e This certifies that the bearer is duty -GREENLOGIC LLC ? Cicensedbythe County of'Suffolk - 05J25f2Q06 I 40227-H 05/0112018 RECD BY: c.icGrisr:rr r rcegrsLraugrrtf:- CL __ �__. 0227. . ._.•._ . -_ - OTAL: Remarks: ` ' 400.00 ATTENTION HOME IMPROVEMENT CONTRACTORS'Suffolk County Code Chapter 563-17(D) states:All advertising'for Home Improvement contracting shall contain the number of the Home Improvement license. Customer copy http://suffolkea/receiptcopy.aspx?ID=314485 4/6/2016 , SUFFOLK COUNTY[SEPT Cif'LABOR,n •_< LICENSING&CONSUMER AFFAIRS MASTER- ELECTRICIAN : <4 ROBERT J SKYPALA 7._ %✓. . This certifies that the tRREENLt3C31C L!G bearer IS duty licensed by the County of Suffolk ,I211012007 43858-ME_ ;Trarz.E�ler�<� csn.n+..mm,.n BXPdfAF.ON OATS 12/01/2((11? CERTIFICATE OF LIABILITY INSURANCEDATE(MMIDD/YYYY) F01/25/2016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Brookhaven Agency,Inc. Brookhaven Agency,Inc. 631 941-4113 Fax PHONE 631 941-4405 128 Old Town Road Suite C =L . brookhaven.agency@veeizon.net PO Box 850 PRODUCER East Setauket NY 11733 INSURERS AFFORDING COVERAGE NAIC 0 INSURED INSURER A. HDI-Gerling America Insurance Co. Greenlogic,LLC INSURER B.- Merchants Preferred Insurance Co. 425 County Road 39A,Suite 202 INSURER C: First Rehab Life Insurance Co. Southampton,NY 11968 INSURER D: Endurance American Insurance Company INSURER E: AGCS Marine Insurance Com an INSURER F: National Liability&Fire Insurance Co. COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADOL SUBR POLICY EFF POLICY EXP POLICY NUMBER LIMITS GENERAL LIABILITY EACH OCCURRENCE $1,000,000 A X COMMERCIAL GENERAL LIABILITY X X EGGCC000076916 01/31/16 01/31/17 DAMAISE GE TO RENTED $100,000 CLAIMS-MADE FX-1 OCCUR MED EXP(Any oneperson) $5,000 X XCU PERSONAL&ADV INJURY $1,000,000 X Contractual Liab GENERAL AGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER PRODUCTS-COMP/OP AGG $2,000,000 POLICY FX I AFrT F-1 PRO- LOC $ AUTOMOBILE LIABILITY CO BI EDt )SINGLE LIMIT 1150009000 B X ANY AUTO CAPI043565 8111115 8111116 (EaBODILY INJURY(Per person) $ ALL OWNED AUTOS BODILY INJURY(Per accident) $ SCHEDULED AUTOS X HIRED AUTOS PROPERTY DAMAGE $ Per accident X NON-OWNED AUTOS $ $ X UMBRELLA LUkB X OCCUR EACH OCCURRENCE $1,000,000 D EXCESS LIAR CLAIMS-MADE X X EXCI 0006421400 _ 01/31/15 01/31/16 AGGREGATE $1,000,000 DEDUCTIBLE $ RETENTION $ WORKERS COMPENSATION - X WC STATU- OTH- AND EMPLOYERS'LIABILITY F ANY PROPRIETOR/PARTNER/EXECUTIVEF] N/A V9WC653352 6/15115 6/15116 E L EACH ACCIDENT $1,000,000 OFFICERIMEMBER EXCLUDED? (Mandatory In NH) E L DISEASE-EA EMPLOYEE $1,000,000' If yes,describe under DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $1,000,000 C NYS Disability D251202 4/11/15 4111116 Statutory Limits E Installation Floater/Pro ert MX183958282 4/15/15 4/15116 $1,000,000 $1,000 Dad DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additional Remarks Schedule,If more space Is required) CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE <� J ©1988-2009 ACORD CORPORATION. All rights reserved. ACORD 25(2009/09) The ACORD name and logo are registered marks of ACORD STATE OF NEW YORK WORKERS'COMPENSATION BOARD CERTIFICATE OF NYS WORKERS' COMPENSATION INSURANCE COVERAGE Ia.Legal Name&Address of Insured(Use street address only) lb.Business Telephone Number of Insured Greenlogic LLC 631-771-5152 425 County Rd 39A Ste 202 lc.NYS Unemployment Insurance Employer Southampton NY 11968 Registration Number of Insured Id.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage Is or Social Security Number spec fcally limited to certain locations In New York Stale,le.,a 203801194 Wrap-Up Policy) 2.Name and Address of the Entity Requesting Proof of 3a. Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) National Liability&Fire Insurance Company Town Of Southold 3b.Policy Number of entity listed in box"la" Building Department V9WC794777 53095 Route 25 3c. Policy effective period Southold,NY 11971 06/15/16 to 06/15/2017 3d. The Proprietor,Partners or Executive Officers are included. (Only check box if all partnersloMcers included) X all excluded or certainpartners/officers excluded. This certifies that the insurance carrier indicated above in box"3" insures the business referenced above in box "la" for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(M)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"T'. The Insurance Carrier will also note the above certificate holder within 10 days IF a policy is canceled due to nonpayment ofpremiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices maybe sent by regular mail.) Otherwise,this Ceri ficate Is valld for oneyear after this form Is approved by the Insurance carrier or Its licensed agent,or until the policy expiration date listed in box"3c'.,whichever is earlier. Please Note: Upon the cancellation of the workers' compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by:NICHOLAS ZULKOFSKE (print n of authorized representative or licensed agent of insurance carrier) Approved by: Ma 23 2016 (Date) Title: Authorized Agent Telephone Number of authorized representative or licensed agent of insurance carrier: 631-941-4113 Please Note. Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2(9-07) www.wcb.state.ny.us Workers' Compensation Law 1:-TAIN STORM WATER RUNOFFDAT) - i„SUANT TO CHAPTER 236 �{ r� Pacifico Engineering PC _ ' lF T(. 'i QODE Engineering Consulting 700 Lakeland Ave, Suite 26 Ph: 631-988-0000 Bohemia, NY 11716GIlV� 11� G c Fax: 631-382-8236 www.pacificoengineering.com _ _ e I solar@pacificoengineering.com May 17, 2016 sf"i� b7t CN/ f Town of Southold Building Department �iSE IS UNLAWFUL 54375 do to 159P O. Box 117971 I �� � C ����C��� APPR VED AS NOTED SouthoDATE �� Subject: Solar Energy lnstallati F OC r%A/ B.P.# o UT FEE. BY; Stephen Mitchell Section. 86 NOTI Y BUILDING DEPARTMENT AT 7132 Indian Neck Lane Block: 7 765-1802 8 AM TO 4 PM FOR THE Peconic, NY 11958 Lot: 8 ComjP ;, 0-F'H ALL is OLDES OF FOLLOWING INSPECTIONS:, [NEVI/YORK S i A; E & TOWN CODES 1. FOUNDATION - TWO REQUIRED REQl1�P�ED ��1� , _, FOR POURED CONCRETE AS 2. ROUGH - FRAMING & PLUMBING T i �� 3. INSULATION 4. FINAL - CONSTRUCTION-MUST S0u'i F a—L)TO,NN PL7711 BE COMPLETE FOR C.O. SO'i- r r.+, T c7 r$ ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE-CODES OF NEW � �L���� �j`!•S. 1 _- YORK STATE. NOT RESPONSIBLE FOR I have reviewed the roofing structure at the subject address.The structure cad'F9tli• c� FthC ff IfflV'i i, WIghEWORS. the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2010 NYS Building Code, and ASCE7-05 when installed in accordance with the manufacturer's instructions. Roof Section A B C D Mean roof height 19 ft 19 ft 19 ft _ 19 ft Pitch 10 3/4 in/12 10 3/4 in/12 10 3/4 in/12 10 3/4 in/12 Roof rafter 2x10 2x10 2x10 2x10 Rafter spacing 16 inch on center 16 inch on center 16 inch on center 16 inch on center Reflected roof rafter span 12.6 ft 12.6 ft 9.8 ft 8.8 ft Table R802.5.1(1)max allowable 20.6 ft 20.6 ft 20.6 ft 20.6 ft The climactic and load information is below: CLIMACTIC AND Ground wind Live load, point Exposure Speed,3 pnet30 per GEOGRAPHIC DESIGN Category Snow Load, sec gust, ASCE 7, Pullout Fastener type CRITERIA Pg mph psf load,Ib Roof Section A C 20 120 33 303 SS 5/16"dia screw,4-1/2"length,2 per(3.5"min embedment) B 33 451 SS 5/16"dia screw,4-1/2"length,2 per(3.5"min embedment) C 33 303 SS 5/16"dia screw,4-1/2"length,2 per(3.5"min embedment) D 33 451 SS 5/16"dia screw,4-1/2"length,2 per(3.5"min embedment) Weight Distribution �� �" �� � N Ac �P•<<G OW Y array dead load 3.5 psf , ,. �, load per attachment 293.4 ib S S E���,T �� REWRED P c Subject roof has one layer of shingles Panels mounted flush to roof no higher than 6 inches above surface. rr ro Ralph Pacifico, PE Z�'� 06 Professional Engineer Ralp �QfOA -18f t` � neer NY 063'2a 44306 r GREENL�OGOV' ENERGY GreenLogic,LLC Approved Stephen Mitchell 7132 Indian Neck Lane Peconic,NY 11958 Surface#A: Total System Size:19.430kW Array Size:6.365kW 1 string of 5 and 2 strings of 7 on SB- 6000TL Azimuth:244° Pitch:42" Monitoring System: SunPower _ Panel/Array Specifications: Panel:SPR-X21-335-BLK Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'7 W X 20'7 1/16" Surface:25'9"X 21' Magic#:Invisimount Legend: �] 19 SunPower 335W Panels SunPower Invisimount Rail • 50 UniRac Standoffs Ba2x10"Douglas Fir Rafter 16 O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,UniRac, SunPower,SMA Added Roof load of PV System:3.5 sf Engineer/Architect Seal: of Re yo ,p sti Drawn By:MM rawing#2 of 14 Date:5/10/2016 REV:A Drawing Scale:3116"=1.0' c�REENLOG M" EN FRGY GreenLogic,LLC Approved Stephen Mitchell 7132 Indian Neck Lane Peconic,NY 11958 Surface#A: Total System Size:19.430kW Array Size:6.365kW 1 string of 5 and 2 strings of 7 on SB- 6000TL Azimuth:244' Pitch:42° 3 Monitoring System: SunPower PaneVArray Specifications: Panel:SPR-X21-335-BLK 3 2 Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'7'/"X 20'7 1/16" Surface:25'9"X 21' Magic#:Invisimount 2 Legend: Q 19 SunPower 335W Panels SunPower Invisimount Rail • 50 UniRac Standoffs 2 H 2x10"Douglas Fir Rafter 16 O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface-4" 1 Materials Used:Eco-Fasten,UniRac, SunPower,SMA Added Roof load of PV System:3.5 sf Engineer/Architect Seal: 1 SOF NEIV QN PA � O NCO 666182 A,40FESSI�NP�. Drawn By:MMB Drawing#3 of 14 Date:5/10/2016 REV:A Drawing Scale:3/16"=1.0' G EENLO C" ENERGY GreenLogic,LLC Approved Stephen Mitchell 7132 Indian Neck Lane Peconic,NY 11958 Surface#B: Total System Size:19.430kW Array Size:6.700kW 1 string of 6 and 2 strings of 7 on SB- 7000TL Azimuth:156° Pitch:42° Monitoring System: SunPower Panel/A7-VX rray Specifications: Panel:SPR-X21-335-BLK Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:31'411/16"X 18'9 3/8" Surface:38'9"X 21' Magic#:Invisimount Legend: [[�] 20 SunPower 335W Panels SunPower Invisimount Rail 37 UniRac Standoffs 8 a 2x10"Douglas Fir Rafter 16 O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Matenals Used:Eco-Fasten,UniRac, SunPower,SMA Added Roof load of PV System:3.5 sf Engineer/Architect Seal: or- NEdNY �P PSP PAC��i W 2(P '�sem; —.✓ O X66 i SZ A��FESSIONP� Drawn By:MMB Drawing#4 of 14 Date:5/10/2016REV.A Drawing Scale:3/16"=1.0' GREENLOGOCO ENERGY GreenLogic,LLC Approved Stephen Mitchell 7132 Indian Neck Lane Peconic,NY 11958 Surface#B: Total System Size:19.430kW Array Size:6.700kW 1 string of 6 and 2 strings of 7 on SB- 7000TL Azimuth:156" Pitch:42" Monitoring System. N SunPower _ Panel/Array Specifications: Panel:SPR-X21-335-BLK Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:31'4 11/16"X 1819 3/8" Surface:38'9"X 21' Ma is#:Invisimount Legend: © 20 SunPower 335W Panels -- SunPower Invisimount Rail • 37 UniRac Standoffs 2x10"Douglas Fir Rafter 16 O.C. Notes: Number of Roof Layers: 1 Height above Roof-Surface:4" Materials Used:Eco-Fasten,UniRac, SunPower,SMA Added Roof load of PV System:3.5 sf Engineer/Architect Seal: LH OF Me �QH PAc�,a O s n LU (P f 066182 Drawn By:MMB Drawing#5 of 14 Date:5/10/2016 REV:A Drawing Scale:3116"=1.0' &GREENLOMC" -9 ENERGY GreenLogic,LLC Approved Stephen Mitchell 7132 Indian Neck Lane Peconic,NY 11958 Surface#B: Total System Size:19.430kW Array Size:6.700kW 1 string of 6 and 2 strings of 7 on SB- 7000TL Azimuth: 156° Pitch:42° Monitoring System: N SunPower 4 5 PaneUArray Specifications: Panel:SPR=X21-335-BLK Racking:SunPower Invisimount Panel:61.39"X 41.18" LN Array:31'4 11/16"X 18'9 3/8" Surface:38'9"X 21' 4 3 Magic#:Invisimount 5 Legend: EM 20 SunPower 335W Panels SunPower Invisimount Rail • 37 UniRac Standoffs H2x10"Douglas Fir Rafter 16 O.C. 3 5 Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,UniRac, SunPower,SMA Added Roof load of PV System:3.5 sf Engineer/Architect Seal: �0 NEIY P�PH PAC/� O �r e Ztn 06618`1 !v= A. OFESSIONP� • Drawn By:MMB Drawing#6 of 14 Date:5/10/2016 REV:A Drawing Scale:3116"=1.0' ENERGY GreenLogic,LLC Approved Stephen Mitchell 7132 Indian Neck Lane Peconic,NY 11958 Surface#C: Total System Size:19.430kW Array Size:2.345kW 1 string of 7 on SB-6000TL(shared with S#D) Azimuth:156° Pitch:42" Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X21-335-BLK Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:15'10 5/8"X 13'8 3/4' Surface:20'1"X 17'4" Magic#:Invisimount Legend: Q 7 SunPower 335W Panels SunPower Invisimount Rail • 22 UniRac Standoffs a2x10"Douglas Fir Rafter 16 O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,UniRac, SunPower,SMA Added Roof load of PV System:3.5 sf Engineer/Architect Seal: P�PN PACj� O 066 is �OFESS1010 Drawn By:MMB Drawing#7 of 14 Date:5/10/2016 REV:A Drawing Scale:3116"=1.0' GREENLO���� - - ENERGY GreenLogic,LLC Approved Stephen Mitchell 7132 Indian Neck Lane Peconic,NY 11958 Surface#C: Total System Size:19.430kW Array Size:2.345kW 1 string of 7 on SB-6000TL(shared with S#D) Azimuth:156" Pitch:42" Monitoring System: N SunPower Panel/Array Specifications: Panel:SPR-X21-335-BLK Racking:SunPower Invisimount Panel:61.39"X 41.18,, Array:15'10 5/8"X 13'8 3W Surface:20'1"X 17'4" Magic#:Invisimount Legend: ® 7 SunPower 335W Panels SunPower Invisimount Rail • 22 UniRac Standoffs 2x10"Douglas Fir Rafter 16 O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" - Materials Used:Eco-Fasten,UniRac, SunPower,SMA Added Roof load of PV System:3.5 sf Engineer/Architect Seal: of NEIN)- N PA _ s 7� r— n W N�4A 0661 SZ ��C9 RO SS1o�'P� Drawn By:MMB Drawing#8 of 14 Date:5/10/2016 REV:A Drawing Scale:3/16"=1.0' =C" E1\1ERGY Green Logic,LLC Approved Stephen Mitchell 7132 Indian Neck Lane Peconic,NY 11958 Surface#C• Total System Size:19.430kW Array Size:2.345kW 1 string of 7 on SB-6000TL(shared with S#D) Azimuth:156° Pitch:42" Monitoring System: N SunPower 6 Panel/Array Specifications: Panel:SPR-X21-335-BLK Racking:SunPower Invisimount Panel:61.39"X 41.18" 6 Array:15'10 518"X 13'8'/" Surface:20'1"X 17'4" Magic#:Invisimount Legend: 7 SunPower 335W Panels 6 o SunPower Invisimount Rail • 22 UniRac Standoffs a2x10"Douglas Fir Rafter 16 O.C. 6 Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,UniRac, SunPower,SMA Added Roof load of PV System:3.5psf Engineer/Architect Seal: 'C,;�'OF NFb y P�PNA PAC�� l �O 066182 A'4pj�ESSl4�.1P�' Drawn By:MMBDrawing#9 of 14 Date:5/10/2016 REV:A Drawing Scale:3/16"=1.0' GREEND ENFERGY Green Logic,LLC Approved Stephen Mitchell 7132 Indian Neck Lane Peconic,NY 11958 Surface#D• Total System Size:19.430kW Array Size:4.020kW 2 strings of 6 on SB-6000TL(shared with S#C) Azimuth:156" Pitch:42" Monitoring System: N SunPower Panel/Array Specifications: Panel:SPR-X21-335-BLK _x txRacking:SunPower Invisimount Panel:61 39"X 41.18" Array:13'11"X 10'2 34" Surface:36'11"X 16' Magic#:Invisimount Legend: 12 SunPower 335W Panels SunPower Invisimount Rail ® 26 UniRac Standoffs BO 2x10"Douglas Fir Rafter 16 O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten,UniRac, SunPower,SMA Added Roof load of PV Sy stem:3.5 sf Engineer/Architect Seal: OF NE(ij/� P�QN PA Q �s Z � � FO 0661 BT AR�FESSIONA� Drawn By:MMB Drawing#10 of 14 Date:5/10/2016 REV:A Drawing Scale:3/16" 4 13 GREE LOV C- ��,� ENE13GY GreenLogic,LLC Approved Stephen Mitchell 7132 Indian Neck Lane Peconic,NY 11958 Surface#D• Total System Size:19.430kW Array Size:4.020kW 2 strings of 6 on SB-6000TL(shared with S#C) Azimuth:156" Pitch:42° Monitoring System: N SunPower Panel/Array Specifications:- Panel:SPR-X21-335-BLK PC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:13'11"X 10'2 W Surface:36'11"X 16' Magic#:Invisimount Legend: Q 12 SunPower 335W Panels — SunPower Invisimount Rail • 26 UniRac Standoffs O2x10"Douglas Fir Rafter 16 O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Matenals Used:Eco-Fasten,UniRac, SunPower,SMA Added Roof load of PV System:3.5 sf Engineer/Architect Seal: 0 NEwr \.QN PACS O r.,, 2 �O 066182 A%pissIoNP� Drawn By:MMB Drawing#11 of 14 Date:5/10/2016 REV:A Drawing Scale:3/16"=1.0' GREENLOMCO ENERGY GreenLogic,LLC Approved Stephen Mitchell 7132 Indian Neck Lane Peconic,NY 11958 Surface#D: Total System Size:19.430kW Array Size:4.020kW 2 strings of 6 on SB-6000TL(shared with S#C) Azimuth:156° Pitch:42" Monitoring System: ti =4 7 7 1 7 SunPower 7 8 Panel/Array Specifications: Panel:SPR-X21-335-BLK Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:13'11"X 10'2'/" Surface:36'11"X 16' Magic#:Invisimount 7 Legend: B 12 SunPower 335W Panels SunPower Invisimount Rad • 26 UniRac Standoffs O2x10"Douglas Fir Rafter 16 O.C. 7 Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,UniRac, SunPower,SMA Added Roof load of PV System:3.5 sf Engineer/Architect Seat: C�OF N��r P�PH PqC� O LU °66182 �l,= A�0 SS1014 Drawn By:MMB Drawing#12 of 14 Dale:5/10/2016 REV:A Drawing Scale:3/16"= 1.0' No Vent Pipes Will Be Covered By The Solar ArrayE ®G��T, ENERGY Green Logic,LLC Approved Stephen Mitchell 7132 Indian Neck Lane Meter Peconic,NY 11958 I Total System Size.19.430kW 1 string of 5 and 2 strings of 7 on SB-60WTL 1 string of 6 and 2 strings of 7 on SB-7000TL ———————————————— 1 string of7and 2strings of6onSB-6000TL Azimuth:156" '4'1Pitch:42' Monitoring System: SunPower 12 SunPower 18" Service Panel/Array Specifications: 335W Panels Walkway Panel:SPR-X21-335-BLK Racking:SunPower Invisimount Panel:61.39"X 41.18" I Magic#:Invisimount Legend: - 58 SunPower 336W Panels ---------� — SunPower Invisimount Rail 7 SunPower • 135 UniRac Standoffs 335W Panels 2x10"Douglas Fir Rafter 16 O.C. Notes: I Number of Roof Layers:1 - Height above Roof Surface:4". I Materials Used:Eco-Fasten,UniRac, I 18" Service SunPower,SMA I Added Roof load of PV System:3.5 sf Walkway Engineer/Architect Seal: 19 SunPower ------------------- of NE►,y 335W Panels I QH PAb 7K C/ I I f�f► r W 20 SunPower I 327W Panels �� °66182 '-------- ��FESSIONP� 18" Service Drawn By: Da Drawing#13 of 14 Walkway Date:5/10/2016 REV:A Drawing Scale:1/16"=1.0' -def�G EENLGVC' f-lVE-i\GY Green Logic,LLC Approved Stephen Mitchell 7132 Indian Neck Lane Peconic,NY 11958 Total System Size:19.430kW 1 string of 5 and 2 strings of 7 on SB-6000TL 1 string of 6 and 2 strings of 7 on SB-700OTL 1 string of 7 and 2 strings of 6 on SB-600OTL Azimuth:156° Pitch:42" Monitoring System. Material List qty, Rail Material list QtV- SunPower PaneIVArray Specifications: Unillac 4"Drk Standoffs 135 Invisimount 50 Panel:SPR-X21-335-BLK 5/16"x4.5"SS Lag Bolts 270 Racking:SunPower Invisimount Panel:61.39"X 41.18" 5/16"Stainless Steel Washers 270 Magic#:Invisimount Legend: 58 SunPower 335W Panels SunPower Invisimount Rail • 135 UniRac Standoffs 8 8 2x10"Douglas Fir Rafter 16 O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,UniRac, SunPower,SMA Added Roof load of PV System:3.5 sf Engineer/Architect Seal: �of NEty �P�QN PAC/� Y� n� w Z �O 066182 A��FESSIO�P� Drawn By:MMB Drawing ffq Date:5/10/2016 REV:A Drawing Scale:1/16"=1.0' SUNPOWER' X-SERIES • . . PANELS MORE UNMATCHED PERFORMANCE, RELIABILITY &AESTHETICS Al al SERIES ------------- II • 21.5%efficiency Ideal for roofs where space is at a premium or where future expansion might be needed. SIGNATURE"mBLACK X21 345 PANEL • Maximum performance X21 -335 PANEL Designed to deliver the most energy in HIGHEST EFFICIENCY6 demanding real world conditions, in partial shade and hot rooftop temperatures ''2'3 Generate more energy per square foot • Premium aesthetics X-Series residential panels convert more sunlight to electricity producing 44% SunPower'Signature'' Black X-Series panels more power per panel,'and 75% more energy per square foot over 25 blend harmoniously into your roof. The most years 3,4 elegant choice for your home HIGHEST ENERGY PRODUCTION 7 Produce more energy per rated watt High year one performance delivers 8-10% more energy per rated watt.' This advantage increases over time, producing 21% more energy over the first 25 years to meet your needs.4 - - 120°i° 21 % — More Energy 110% Per Rated Watt Maxeon®Solar Cells:Fundamentally better. 0 9%more,year 1 100% Engineered for performance,designed for durabilityovv- 2 90% 36%more, a year 25 Engineered for peace of mind 80% Designed to deliver consistent, trouble-freeW 70% a of d energy over a very long lifetime 4,5 r 60i° to N 0 5 10 15 20 25 50% Designed for durability Years ��aEkGY AFF The SunPower Maxeon Solar Cell is the only ( f] cell built on a solid copper foundation. Virtually o 10%° - " Maintains High � PHOTON impervious to the corrosion and cracking that8%Conventionalane ���� Power at High Temps ?O�?FIELOtFS� degrade Panels 4'S No Light-Induced Awarded to o Same excellent durability as E-Series panels a 6% Degradation SunPower E-Senes XSeries delivers even #1 Ranked in Fraunhofer durability test.10 Q High Average Watts more energy? o + 4% ---- -- - '— " - Better Low-Light and 100/ power maintained in Atlas 25 comprehensive PVDI Durability test '' 2%2 Spectral Response High-Performance Anti-Reflective Glass } 0% sunpowercorp.com W E P • X-SERIES SOLAR P . . . . MORE •R SUNPOWER OFFERS THE BEST COMBINED POWER AND PRODUCT WARRANTY F POWER WARRANTY PRODUCT WARRANTY 100% 95% �a f 85% 80% a a '- -----------�_.� VYtiI '�f1L 75% 0 5 10 15 20 25 0 5 10 15 20 25 Years Years More guaranteed power.95%for first 5 years,-0.4%/yr.to year 25.s Combined Power and Product Defect 25 year coverage that includes panel replacement costs.9 ELECTRICAL DATA F OPERATING CONDITION AND MECHANICAL DATA X21-335-BLK X21-345 FTemperature —40°F to+185aF(—40aC to+85aC) Nominal Power12(Pnom) 335 W 345 W Max load Wind:50 psf,2400 Pa,245 kg/m2 front&back Power Tolerance +5/-0% +5/-0% Snow. 112 psf,5400 Pa,550kg/m2 front Avg. Panel Efficienc 73 21.1% 21.5% Impact y � 1 inch (25 mm)diameter hail at 52 mph (23 m/s)—� Rated Voltage(Vmpp) 57.3 V 57.3 V resistance I Appearance Class A+ Rated Current(Impp) 5 85 A 6 02 A Solar Cells 96 Monocrystalline Maxeon Gen III Cells Open-Circuit Voltage(Voc) 67.9 V 68.2 V Tempered Glass High Transmission Tempered Anti-Reflective Short-Circuit Current(Isc) 6 23 A 6 39 A Junction Box IP-65 Rated F Maximum System Voltage 600 V UL; 1000 V IEC_ _ _ j Connectors_ MC4_C_ompatible Maximum Series Fuse 20A Frame Class 1 black anodized,highest AAMA Rating Power Temp Coef. (Pmpp) —0_30%/aC L Weight _ 41 lbs(18.6 kg) Voltage Temp Coef (Voc) —167 4 mV/oC Current Temp Coef. (Isc) 3.5 mA/oC F TESTS AND CERTIFICATIONS REFERENCES —Sta tests UL 1703, IEC 61215, IEC 61730 _ F 1 All comparisons are SPR-X21-345 vs a representative conventional panel 240W, Quality tests ISO 9001:2008,ISO 14001 2004 approx 1.6M2,15%efficiency EHS Compliance RoHS,OHSAS 18001:2007, lead-free 2 PVEvolution Labs"SunPower Shading Study,"Feb 2013. Ammonia test IEC 62716 3 Typically 8-10%more energy per watt,BEW/DNV Engineering"SunPower Yield Report," -- Jan 2013,with CFV Solar Test Lab Report#12063,Jan 2013 temp.Coef.calculation. Salt Spray test IEC 61701 (passed maximum severity) 4 SunPower 0 259/o/yr degradation vs 1.0%o/yr conv,panel.Campeau,Z et al "SunPower PID test Potential-Induced Degradation free: l 000V 70 Module Degradation Rate,"SunPowerwhite paper,Feb 2013,Jordan,Dirk"SunPower Available listings CEC,UL,TUV,MCS Test Report,"NREL,Oct 2012. 5"SunPower Module 40-Year Useful Life"SunPower white paper,Feb 2013 Useful life is 99 out of 100 panels operating at more than 70%of rated power. 6 Higher than E Series which is highest of all 2600 panels listed in Photon Infl,Feb 2012 7 1%more energy than E-Senes panels,8%more energy than the average of the top 10 panel companies tested in 2012(151 panels,102 companies),Photon Intl,Mar 2013 8 Compared with the top 15 manufacturers SunPower Warranty Review,Feb 2013. 1046mm 9 Some exclusions apply See warranty for details [41.21n] 10 X-Series some as E-Series,5 of top 8 panel manufacturers were tested by Fraunhofer ISE,"PV Module Durability Initiative Public Report,"Feb 2013 11 Compared with the non-stress-tested control panel X-Series some as E-Senes,tested in Atlas 25+Durability test report,Feb 2013 46mm 1 12 Standard Test Conditions measured W/mlower irradiances g 1.5, do C). 1559mm 13 Based on average of measured power values during production [1.811n]� [61.4in] See htto://www sunpowercorp com/facts for more reference information For further details,see extended datasheet.www sunpowercorp com/datasheets Read safety and installation instructions before using this product ©April 2013 SunPower Corporation All rights reserved SUNPOWER,the SUNPOWER logo,MAXEON,MORE ENERGY FOR LIFE,and SIGNATURE are trademarks or registered trademarks of SunPower SUnpOWerCOrp.COm Corporation Specifications included in this datasheet are subject to change without notice Document#504828 Rev A/LT EN SUNNY BOY 3000TL-US 380OTL-US /40001L-US 5000TL-US 600OTL-US 700OTL-US 7700YL-US �N Fes, � ��ri��}!�- ,fi '� � 9f4��,v`r-- Ir h� 1z' SIPS THE WORLD'S ONLY SECURE POWER SUPPLY 7� -Z C, A- 14795, ly, 4 7� Certified Innovative Powerful Flexible •UL 1741 and 1699B compliant •Secure Power Supply provides -97.6%maximum efficiency -Two MPP trackers provide •Integrated AFCI meets the require- daytime power during grid outages -Wide input voltage range numerous design options ments of NEC 2011 690.11 -Shade management with OptiTrac -Extended operating Global Peak MPP tracking temperature range SUNNY BOY 3000TL-US / 380OTL-US /4000TL-US 5000TL-US / 6000TL-US / 7000TL-US / 770OTL-US Setting new heights in residential inverter performance The Sunny Boy 300OTL-US/380OTL-US/400OTL-US/500OTL-US/600OTL-US/700OTL-US/770OTL-US represents the next step in performance for UL certified inverters.Its transformerless design means high efficiency and reduced weight.Maximum power production is derived from wide input voltage and operating temperature ranges. Multiple MPP trackers and OptiTracTm Global Peak mitigate the effect of shade and allow for installation at challenging sites.The unique Secure Power 10,1 H Th'r Supply feature provides daytime power in the event of a grid outage. High performance, flexible design and innovative MEfeatures make the Sunny Boy TL-US series the first choice among solar professionals. 0 t Sm %P 4" ,I 09-11P Technical data Sunny Boy 3000TL-US Sunny Boy 380OTL-US Sunny Boy 4000TL-US 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 240 V AC Input(DC) Max usable DC power(Q cos(p=1) 3200 W 4200 W 4200 W Max DC voltage 600 V 600 V 600 V Rated MPPT voltage range 175-480 V 175-480 V 175-480 V MPPT operating voltage range 125-500 V 125-500 V 125-500 V Min DC voltage/start voltage 125 V/150 V 125 V/150 V 125 V/150 V Max operating input current/per MPP tracker 18 A/15 A 24 A/15 A 24 A/15 A Number of MPP trackers/strings per MPP tracker 2/2 Output(AC) AC nominal power 3000 W 3330 W 3840 W 4000 W Max AC apparent power 3000 VA 3330 VA 3840 VA 4000 VA Nominal AC voltage/adjustable 208 V/* 240 V/• 208 V/0 240 V/0 208 V/• 240 V/• AC voltage range 183-229 V 211 -264 V 183-229 V 211 -264 V 183-229 V 211 -264 V AC grid frequency,range 60 Hz/59 3-60.5 Hz 60 Hz/59 3-60 5 Hz 60 Hz/59 3-60 5 Hz Max output current 15 A 16 A 20A Power factor(cos P) I 1 1 Output phases/line connections 1/2 1/2 1/2 Harmonics <4% <4% <4% Efficiency Max efficiency 97.2% 976% 972% 975% 972% 975% CEC efficiency 965% 965% 96.5% 970% 965% 970% Protection devices DC disconnection device 0 DC reverse-polanty protection • Ground fault monitoring/Grid monitoring 0/0 AC short circuit protection 0 All-pole sensitive residual current monitoring unit • Arc fault circuit interrupter(AFCI)compliant to UL 1699B • Protection class/overvoltage category I/IV General data Dimensions(W/H/D)in mm(in) 490/519/185 (193/205/73) DC Disconnect dimensions(W/H/D)in mm(in) 187/297/190 (7 4/11 7/7 5) Packing dimensions(W/H/D)in mm(in) 617/597/266 (24 3/23 5/10 5) DC Disconnect packing dimensions(W/H/D)in mm(in) 370/240/280 (14.6/9 4/1 1 0) Weight/DC Disconnect weight 24 kg (53 Ib)/3 5 kg (8 Ib) Packing weight/DC Disconnect packing weight 27 kg (60 Ib)/3 5 kg (8 16) Operating temperature range -40°C +60°C (-40°F +140°F) Noise emission(typical) 5 25 dB(A) <25 dB(A) <25 dB(A) Internal consumption at night <1 W <1 W <1 W Topology Transformerless Transformerless Transformerless Cooling Convection Convection Convection Electronics protection rating NEMA 3R NEMA 3R NEMA 31Z Features Secure Power Supply • • 0 Display graphic • 0 • Interfaces.RS485/Speedwue/Webconnect 0/0 0/0 0/0 Warranty 10/15/20 years 0/0/0 0/0/0 0/0/0 Certificates and permits(more available on request) UL 1741,UL 1998,UL 16998,IEEE1547,FCC Part 15(Class A&B),CAN/CSA C22 2 107 1-1 NOTE US inverters ship with gray lids Type designation SB 3000TL-US-22 SB 380OTL-US-22 SB 4000TL-US-22 More efficient Shade management Easier 14 - +1401F;I ,� � � I - o Secure Power Supply Broad temperature range Flexible communications A NEW GENERATION OF INNOVATION THE SUNNY BOY TL-US RESIDENTIAL SERIES HAS YET AGAIN REDEFINED THE CATEGORY Transformerless design in all types of climates and for longer periods of Leading monitoring time than with most traditional string inverters. and control solutions The Sunny Boy 3000TL-US / 380OTL-US / 4000TL-US / 5000TL-US / 6000TL-US / Secure Power Supply The new TL-US residential line features more s 7000TL-US/770OTL-US are transformerless than high performance and a large graphic inverters, which means owners and installers One of many unique features of the TL-US display. The monitoring and control options 9 i benefit from high efficiency and lower weight. residential series is its innovative Secure provide users with an outstanding degree of A wide input voltage range also means the Power Supply. With most grid-tied inverters, flexibility. Multiple communication options Z inverters will produce high amounts of power when the grid goes down, so does the solar- allow for a highly controllable inverter Z-f under a number of conditions powered home. SMA's solution provides and one that can be monitored on Sunny o daytime energy to a dedicated power outlet Portal from anywhere on the planet via an a Additionally, transformerless Inverters have during prolonged grid outages, providing Internet connection. Whether communicating o 1 been shown to be among the safest string homeowners with access to power as long as through RS485, or SMA's new plug-and-play £t inverters on the market.An industry first,the TL- the sun shines. WebConnect, installers can find an optimal r US series has been tested to UL 1741 and UL solution to their monitoring needs. °o 16998 and is in compliance with the arc fault Simple installation E requirements of NEC 2011. Wide Power Class Range sQ As a transformerless inverter, the TL-US Increased energy production residential series is lighter in weight than Whether you're looking for a model to its transformer-based counterparts, making maximize a 100 A service panel or trying 3 OptiTrac"11 Global Peak, SMA's shade- it easier to lift and transport. A new wall to meet the needs of a larger residential PV o 0 tolerant MPP tracking algorithm, quickly mounting plate features anti-theft security and system, the Sunny Boy TL-US with Secure adjusts to changes in solar irradiation,which makes hanging the inverter quick and easy.A Power Supply has you covered. Its wide v g mitigates the effects of shade and results In simplified DC wiring concept allows the DC range of power classes—from 3 to 7.7 kW— higher total power output.And,with two MPP disconnect to be used as a wire raceway, offers customers the right size for virtually any trackers, the TL-US series can ably handle saving labor and materials. residential application.The TL-US series is not complex roofs with multiple orientations or only the smartest inverter on the planet,it's also string lengths. The 380OTL-US and 770OTL-US models allow the most flexible. m installers to maximize system size and energy An extended operating temperature range of production for customers with 100 A and 200 -40 OF to+140 OF ensures power is produced A service panels. 8, Rg Toll Free +1 888 4 SMA USA www.SMA-America.com SMA America, LLC h S ------------------------------__---------------------------------._______ -----------------------i Efficiency curve SUNNY BOY 5000TL-US22 240Vac;'--------------------------- Accessories - ---------- 98 — --- - ---—`- - - - - -- -—- -'-- -- ------ - 96-ri ...........•'•�•--••••••• - ebconnect M-485CMSS10 ..........- ----` -- _ RS485 interface Speedvnre/W • interface D 94 SWDM-US-10 92aeFan kit for SB 3000/3800/ � 90- ----- - ---" - - - 4000/5000TL-US22 FANKIT02-10 75 V) c vs I - 88 86 j 00 02 04 06 08 10 is Standard feature O Optional feature —Not available ---------------------'-----------Output power--Rated power- ----------------------------------- Data at nominal conditions Sunny Boy 5000TL-US Sunny Boy 6000TL-US Sunny Boy 7000TL-US Sunny Boy 7700TL-US 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 240 V AC 5300 W 6300 W 7300 W 8000 W 600 V 600 V 600 V 600 V 175-480 V 210-480 V 245-480V 270-480 V 125-500 V 125-500 V 125-500 V 125-500 V 125V/150V 125V/150V 125V/150V 125V/ISO V 30A/15A 30A/15A 30A/18A 30A/18A 2/2 4550 W 5000 W 5200 W 6000 W 6000 W 7000 W 6650 W 7680 W 4550 VA 5000 VA 5200 VA 6000 VA 6000 VA 7000 VA 6650 VA 7680 VA 208 V/• 240V/• 208 V/• 240 V/• 208 V/• 240 V/• 208 V/• 240V/• 183-229 V 211 -264 V 183-229 V 211 -264V 183-229V 211 -264 V 183-229 V 211 -264 V 60 Hz/59 3-60 5 Hz 60 Hz/59.3-60 5 Hz 60 Hz/59 3-60 5 Hz 60 Hz/59 3-60 5 Hz 22A 25A 292A 32A 1 1 1 1 1/2 1/2 1/2 1/2 <4% <4% <4% <A 972% 976% 970% 974% 968% 968% 968% 973% 965% 970% 965% 970% 965% 965% 965% 965% • • • • I/IV 490/519/185 (193/205/73) 187/297/190 (74/117/75) 617/597/266 (24.3/23 5/10 5) 370/240/280 (14.6/94/110) 24 kg (53 Ib)/3 5 kg (8 Ib) 27 kg (60 Ib)/3 5 kg (8 Ib) -40°C +60°C (-40 IF +140°F) <29 dB(A) <29 dB(A) <29 dB(A) <29 dB(A) <1 W <1 W <1 W <1 W Transformerless Transformerless Transformerless Transformerless Convection Fan Fan Fan NEMA 3R NEMA 3R NEMA 3R NEMA 3R 0/0 0/0 0/0 0/0 •/0/0 •/0/0 0/0/0 •/0/0 UL 1741,UL 1998,UL 16998,IEEE1547,FCC Part 15(Class A&B),CAN/CSA C22 2 107 1.1 SB 5000TL-US-22 SB 6000TL-US-22 SB 7000TL-US22 SB 7700TL-US-22 Al Simple arid Fast Installation ' integrated module-to-ra grounding � ' 'ilre assembled rVdand end clamps _ ` _emLaur,gmid clamp b/easy placement ' M'odampwidth fao:.�auespven mnJu|espaor;J ' S'mple.pre-dri|ed rail splice ' ULI7O3Listed/ncegratedgrounding Flexible Design - ' Adu/esscsnea,l%/a'!sloped rcsidenda|,00fs ' Jeogn'nlandscape and nort' x ' Rai|senable easy ubszacemanagement Custom eFPr8ferredAesthetics ' #1 nudu|eand#` moun.'n(,aesmeL'Ics ' 3est-/n-dasssystem aecd efts Elegant Simplicity ` »'enium.|ov+pro�|edesign ' Black ancd/zedcomponents , SUnpovver+ |Ovis|K4oun�v |saSUDPoYver-deS|gned ' }|iddpnmid clamps and enddamps rail-based n)ouni|nosysiern. The |nv|s|Miounisysiern ha'dwarp and Ous�rai|s � ' addressesresident 8|sloped roofs and [Ornb|-eSfaster Part D[Superior System installation time, deS"cYn4f;ex|b|litY, and superior aestheT'[s ' 3u/|cforu-,eWith SunPowprJCannA( nno,j|es �he |nV:S|Mount product was specifically envisioned and ' [umo/newi,hSunPowermodu|esand engineered {opair with SunPovvermodules The resulting m:nmo�lngapP SYSLemlevel approach will annpNythe, aesihe/'c8nc mS�a|laUOnbenefits for bo�hhOrneOvvners and |ns[8U2rS sUDDOVVe[COOO ,a g nad:056.5 ]�awrtlJQ a.;moo noilm,AwLID ol,)a}{ns a<e loaysa]eu slyj w p.,pnjpu uol,id71}vacs wu),awoduns a.aunho a,>;IpadsaJ I auh] l JO ,adwa aysy :ale ,sulape,_Ja41j I V uollc,od)o:)J-rrcdu.] ,o ssr]ewap,, }r;,.a], 'a .o'4rwai,e.l aJt 1A:`1044;ISihNi uue'oo<)d?r:;p,-raf lS a-r]'a:7-x,0�_r:`;i Pa:.�asa_c3�d2'u IIV OZ ='alnyeJadn.rJu,<f,ehhp,?y to;GOnnb,;J U.la'.SAS 1-�noyyls nul ay]'111 o olcla-.iww s1]eu]au,eJ,appol," 'x;gp,uown)op s JjwnDe;nueu.,a_emp,ey ula.uy)2_1e}oo-o:Ja43y - - s]uawy)elxd,00y JG-j1C)10;r)a;Ja;ui,esaaro.Iti --- I 1uaU,!uc'],ddoo»j d1111''ij pue 0an,nD . - _9t! ,°° " JU3JJU,-e1JV Sun1)at);oo�}alSuly,uo,alsod uo:) Ja)jeaOw i 3uu}5 uo'71sad,.]o� sl a..JeJ;all Ipow . Mowmm"_@i I,7tMOdun5}o 11•ol+oq pue a)pj1nsJOOJ ®. Ua;,rllaa a)ue]slp aOyM Sidle,JJU y slap ' suorler;WD (70/z 0)$b 0! aWfiO Jo;(NJCid)iela)e d?D pu3 w tnnI Js,ddo)pa:eld-uil-loq GL-ZV) llrlwassy (zo SL 6) 5 90 G ssaluiels b0F 3n-I punoig 1;UeJJ?!A'.IS+JIJ Jed/j _ Fl u SUIlUBJ 1ef,/ S.._-S009 frlip-wnuminIVi DDiIdo Im_n,m % 022 ... FIQu (0/70 6)W/e oa 91-SO:J9;c e Wnulwnl:_paz1p0ue y)ely pe` =.; -- (zu gg�)8;;,L �3 uuuuwn1a px170ue>IJe18 u.l,ep pub - — — —, (zo Z Zi S F9 1 v05 1,1,v lads ssalwels apu'o>I)el� dwe py4DD-10JUAV), op I ed 007Z ]u$rarh 1'-ua7el•"! (J t-610=_),nt,-)7.06o1D-Ot>- aUiUUd2J lUD' aJrceleaurl sLy^ dei pui l,.lwa'SSV}n";purc.!D a.,qd+,"qj mS p1J duJep 0u3 clule, pq+y( � '.alr„N• d .� c�gg .•, �� ••a.:"' 'x$34..¢:::. d.• �' 'leh pue d,u-c,D pug,,xa npcYN pea pue dWe1-,,)ir!; alnpo�,d a - IS a �.t "•�.,....q; r � Fes.;: R..4,•a•7 i ,'M�-'A 1 '�^ ae:, qd$ VW ,. g,°,wF.r:. eia '4`d, .ci"Y •• •,7 �<�gs ,w+M.irvS ° ''''�aa. � 6 PV—SA-1A-------------------NEW EQUIPMENT-------------------------- ' EXISTING SERVICE A INV-1 B 120/240, 1 PH, 3W N ... 2 1 �_------®� O 0 0 �. INTEGRAL DC/AC I DISCONNECT SWITCH I AC—COMBINER PANEL I I PV—SA-18 I I I AC—CMB-1 PV—SA-2A I G I (LOCATED NEAR INVERTERS) C AC DISCONNECT I D A B I I I (PV LOADS ONLY) , ' N •.. 2 1 INV-2 I AC—DSC-1 1 INTEGRAL DC/AC I I BKR-1 r i MAIN DISCONNECT SWITCH i PV—SA-2B ' PV—SA-3A ti B , I I BKR-2 FUSED 2 1 IV-3 Lz4= BKR-3 m— IEGC N ••• 2 1 INTEGRAL DC/AC IN DISCONNECT SWITCH I I I I PV—SA-3B I � jl I PV—SA-4A Ecc , 2 1 A INV-4 B j l l I N S I EXISTING AC PANELS 0 0 0 EXISTING ® o a _ 'GEC N ••• 2 1 DISCONNECT SWITCH L IINTEGRAL DCAc —4 �WIRING GUTTER I I IGEC I L------��----L_—°e—_—®—°e—_--°iee--T—°e-----e—� PV—SA-4B IRREVERSIBLE SPLICE #4 CU PROPOSED 3-LINE ELECTRICAL DIAGRAM Stephen Mitchell REVISIONS c/o Ray Nemschick GREENLOGICO 7132 Indian Neck Road 0 ENERGY Peconic, NY 11958 1 ) INITIAL SUBMITTAL WITH APPLICATION ELIMINATING THE COST OF ENERGY Page 1 of 3 Drawing No: SMTCHL-3LD1 Revision: 1 Revised: 4/12/2016 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1A PHOTOVOLTAIC SUB-ARRAY SUNPOWER, MODEL SPR-X21-335, 1-STRING OF 4-MODULES PV-SA-1B PHOTOVOLTAIC SUB-ARRAY SUNPOWER, MODEL SPR-X21-335, 1-STRING OF 5-MODULES PV-SA-2A PHOTOVOLTAIC SUB-ARRAY SUNPOWER, MODEL SPR-X21-335, 1-STRING OF 7-MODULES PV-SA-2B PHOTOVOLTAIC SUB-ARRAY SUNPOWER, MODEL SPR-X21-335, 1-STRING OF 8-MODULES PV-SA-3A PHOTOVOLTAIC SUB-ARRAY SUNPOWER, MODEL SPR-X21-335, 1-STRING OF 7-MODULES PV-SA-3B PHOTOVOLTAIC SUB-ARRAY SUNPOWER, MODEL SPR-X21-335, 1-STRING OF 8-MODULES PV-SA-4A PHOTOVOLTAIC SUB-ARRAY SUNPOWER, MODEL SPR-X21-335, 1-STRING OF 7-MODULES PV-SA-4B PHOTOVOLTAIC SUB-ARRAY SUNPOWER, MODEL SPR-X21-335,2-STRINGS OF 6-MODULES INV-1 INVERTER, DC/AC SMA INVERTER, MODEL: SB3000TL-US-22,240V INV-2 INVERTER, DC/AC SMA INVERTER, MODEL: SB5000TL-US-22,240V INV-3 INVERTER, DC/AC SMA INVERTER, MODEL: SB5000TL-US-22,240V INV-4 INVERTER, DC/AC SMA INVERTER, MODEL: SB6000TL-US-22, 240V BKR-1 CIRCUIT BREAKER, INVERTER MATCH COMBINER PANEL BRAND, 2-POLE, 20A BKR-2 CIRCUIT BREAKER, INVERTER MATCH COMBINER PANEL BRAND, 2-POLE, 30A BKR-3 CIRCUIT BREAKER, INVERTER MATCH COMBINER PANEL BRAND, 2-POLE,30A BKR-4 CIRCUIT BREAKER, INVERTER MATCH COMBINER PANEL BRAND, 2-POLE,30A AC-CMB-1 AC COMBINER PANEL 250V,200A, NEMA-1,1-PH, 3-WIRE AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V,200A, NEMA-1, FUSE RATING: 110A PROPOSED EQUIPMENT SPECIFICATIONS Stephen Mitchell REVISIONS c/o Ray Nemschick E E LOGIC® 7132 Indian Neck Road ENERGY Peconic, NY 11958 1.) INITIAL SUBMITTAL WITH APPLICATION ELIMINATING THE COST OF ENERGY Page 2 of 3 Drawing No: SMTCHL-3LD1 Revision: 1 Revised: 4/12/2016 ELECTRICAL LOAD SUMMARY CONDUCTOR SCHEDULE DC CIRCUITS TAG TYPE CONDUIT AWG./EGC TAG OP. CURRENT OP.VOLTAGE MAX.VOLTS S.S.C. A USE-2/PV WIRE 1" PVC-40 10 / 6 @STC @STC @ T-MIN @STC B THWN-2 1" PVC-40 8 / 6 PV-SA-1A 5.85 A DC 192 V DC 302 V DC 6.23 A DC C THWN-2 2" PVC-40 3/0 / 4 PV-SA-1B 5.85 A DC 241 V DC 377 V DC 6.23 A DC D THWN-2 2-1/2" EMT 3/0 / 4 PV-SA-2A 5.85 A DC 337 V DC 528 V DC 6.23 A DC PV-SA-2B 5.85 A DC 385 V DC 598 V DC 6.23 A DC 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND BUNDLING. PV-SA-3A 5.85 A DC 337 V DC 528 V DC 6.23 A DC PV-SA-36 5.85 A DC 385 V DC 598 V DC 6.23 A DC 2•) ELECTRICAL CONDUIT TO BE MIN. PVC SCHEDULE 40, ADJUST FOR SITE CONDITIONS PV-SA-4A 5.86 A DC 337 V DC 528 V DC 6.23 A DC 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION PV-SA-4B 11.70 A DC 289 V DC 453 V DC 12.46 A DC METHODS TO COMPLY WITH NEC AND LOCAL CODE RE- QUIREMENTS. ELECTRICAL LOAD SUMMARY 4.) NOTE:GROUNDING ELECTRODE CONDUCTOR TO BE #4 COPPER. AC CIRCUITS TAG POWER VOLTAGE MAX.AC MAX. DC RANGE CURRENT CURRENT INV-1 3000 WATTS 211-264 VAC 15 A AC 15 A DC INV-2 5000 WATTS 211-264 VAC 22 A AC 30 A DC INV-3 5000 WATTS 211-264 VAC 22 A AC 30 A DC INV-4 6000 WATTS 211-264 VAC 25 A AC 30 A DC PROPOSED EQUIPMENT SPECIFICATIONS Stephen Mitchell REVISIONS c/o Ray Nemschick G R E E N L.OG ICO 7132 Indian Neck Road ENERGY Peconlc, NY 11958 1.) INITIAL SUBMITTAL WITH APPLICATION ELIMINATING THE COST OF ENERGY Page 3 of 3 Drawing No: SMTCHL-3LD1 Revision: 1 Revised: 4/12/2016