HomeMy WebLinkAbout41770-Z FF014, Town of Southold 9/21/2017 P.O.Box 1179 0 co T 53095 Main Rd 11 Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39229 Date: 9/21/2017 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 145 Fawn Ln, Cutchogue SCTM#: 473889 Sec/Block/Lot: 103.4-23 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/19/2017 pursuant to which Building Permit No. 41770 dated 6/29/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Manaris,Gregory&Helen of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 41770 09-12-2017 PLUMBERS CERTIFICATION DATED Authorized Signature v9z=-� - TOWN OF SOUTHOLD off fit 14t, BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41770 Date: 6/29/2017 Permission is hereby granted to: Manaris, Gregory & Helen 145 Fawn Ln Cutchogue, NY 11935 To: install roof mounted solar panels as applied for. At premises located at: 145 Fawn Ln, Cutchogue SCTIVI # 473889 Sec/Block/Lot# 101-4-23 Pursuant to application dated 6/19/2017 and approved by the Building Inspector. To expire on 12/29/2018. Fees: SOLAR PANELS $50.00 CO -ALTERATION TO DWELLING $50.00 ELECTRIC $100.00 ?ot al: $200.00 BJiIding'1n`sM=r- Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6.1 Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9,,1957)non-conforming uses,or buildings and"pre-existing"land-uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features.' 2. A properly completed application and consent'to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.000 / Date. 8 /dL I New Construction: Old or Pre-existing Building: (check one) Location of Property: Ll� IgW4 House No. Street Hamlet Owner or Owners of Property: Gre W( Suffolk County Tax Map No 1000, Section /N,00 Block U Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ ( Applicant Signature Ur^e Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 ® �� roger.richert(b-town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Manaris Address: 145 Fawn Lane city,Cutchogue st: New York zip: 11935 Budding Permit#: 41770 section: 103 Block 4 Lot: 23 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Sunrun Installation Services License No: 33878-ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures �] TVSS Other Equipment: 6,600 WATT Roof-Mounted Photovoltaic System to Include 20 LG 330 Panels, 1- PVI 6000 Inverter AC Disconnect, DC Disconnect with AFCI, Rapid Shut Down. Notes: Inspector Signature: Date: September 12, 2017 0-Cert Electrical Compliance Form.xls pF SO(/jyolo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) REMARKS: DATE I/// C 7 1 NSPECTOR t n152 S. Broad St. Penn FUSION Lansdale, PA 19446 (215)361-8040 August 1, 2017 1 Sunrun Inc. 15 Charlotte Ave Hicksville, NY 11801 RE: Manaris Residence 145 Fawn Ln, Cutchogue, NY 11935 Client Project#: 211R-145MANA PFE Project#: 171324 On behalf of Sunrun Inc., Penn Fusion Engineering LLC (PFE) has reviewed the documentation on the installation of the photovoltaic system at the above referenced location. This office has verified that the PV panels have been installed per the manufacturer's specificaitons and complies with the approved plan of the local jurisdiction and has met or exceeds the New York State Residential building code. If you have any questions regarding this analysis, please feel free to contact us. Best Regards, Penn Fusion Engineering LLC Andrew D,Leone, P.E. Principal ® ., D AUG 1 6 2017 BUILDING DEPT. TOWN OF SOUTHOM OF NEVV),° C-) DOMEN� 'Q 2 � rn n Lu m � 081693 ROfiEssloNP FIELD 3N'SpmpOVU D=. FOUNDA, ftm(1ST) ................-- , ...........- �'OUND�TXQN'�(2N15) � p rA ROUGH FRATYPQ& O !µf TNSULATZON PEA N,Y. y3y�'ii STATE ENBR(V COS7E YXNAL , TS IM ' b A TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 I� ���/f'�� Survey SoutholdTown.NorthFork.net PERMIT NO. ` l./ Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined ,20 Single&Separate Storm-Water Assessment Form Contact: Approved ,20- � Mail to: /5'Clrlalle- Aen�/ Disapproved a/c _f'l(� of 1e [NAI /19(y Phone: Expiration -,20 met i m i- ������ ui mg Inspector ® D APPLICATION FOR BUILDING PERMIT JUN 1 2017 Date����� , 20 INSTRUCTIONS DING be completely fi sets oflqlled in by typewriter or in ink and submitted to the Building Inspector with 4 ,accurate plot plan to scale. Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws, Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) ('ho—IRk 111-AIVIlt n"Itl4kllle LVZ /60 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Aiell LI/ Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. ✓P Other Trade's License No. 1. Locat' n of land on which roposed work will be done: �0) O House Number Street Hamlet County Tax Map No. 1000 Section. 030a, Block Woo Lot Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy / /� �,, b. Intended use and occupancy y Arl-a y A &G� lo✓✓J���t 1/✓ "�'(s 3. Nature of work(check which applicable):New Building Addition Alteratio Repair Removal Demolition Other Work Description) 4. Estimated Cost, go Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear, Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12.Does proposed construction violate any zoning law, ordinance or regulation?YES NO) 13. Will lot be re-graded?YES NO Will excess fill be removed from premises?YES NO K y' - fib 14. Names of Owner of remise Mal& Address ti1N Phone No. 49 Name of Architect Won Address rbe hone No — — Acle- Name of Contractor n h ddress hone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES L NO X * IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OFa�m ) /,, b��'/ being duly sworn, deposes and says that(s)he is the applicant (Na-me of individual signing contract)above named, l (S)He is the 411,f s1 of Gt114 b r / C2 S (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. SwornAo before me 20 l OMAS DEGERONIMO Notary is notary Public,State of NewYork gnature of Applicant No.01 DE6338933 Qualified in Nassau County Commission Expires March 21,20D r i J Scott A. Mussell 0°SUF �G `]F01K1\\ ] WA\r]F1E][, SUPERVISOR 1\M[A\NA\G]E1\\41EN`]F SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 Town of Sou th o l d CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) -- - - -- - - - - - - - -- -- -- - - - - - - ---- -- - - - - --- - --- - -- - - -- - -- - - -- -- - - - - - - - DOES THIS PROJECT INVOLVE ANY OF THE FOLLOWING: Yes No (CHECK ALL THAT APPLY) ❑® A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ®® B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑&D C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑ ] D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑14 E. Site preparation within the one-hundred-year f loodplain as depicted on FIRM Map of any watercourse. ❑0 F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT (Property Owner,Design Professional,Agent,Contractor,Other) S.C.T.M. #: 1000 Date: / Drstnct I 1 NAME f `q_M Cir AO-1) -ow ✓�� L irm P r Section Block Lot 01_ Lg,gnarure) // .F,e.. FOR BUILDING DEP.'A l,Sl ONLY ,... Contact Information ?77 �`( 5/ P 'telephone�umAcri Reviewed By: rv�� &Ah Date — — Property Address/ Location of Construction Work. — — — — — — — — — — — — — l[/S� w� / v—, G ❑ Approved for processing Building Permit. ((J / �— Stormwater Management Control Plan Not Required (tk — — — — — — — — — — — — — — — h ( l iG 55ElStormwater Management Control Plan is Required (Forward to Engineering Department for Review) FORM " SMCP-TOS MAY 2014 i sotlyo Town Hall Annex Telephone(631)765-1802 54375 Main Road N � ,ax(631)765-,gSQ� � P.O.Box 1179 G� Q roger.richert Lown.southo1l .ny us Southold,NY 11971-0959 . OUt�i'I,� I • BUILDING DEPARTMENT ' TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY- Date: Company Name: �. 'SW/n fio, rseev I u's Name- �= License No.: Address: S� ► 6;(-1042 iqVeo te Phone No.- R1- M — fd f 1 JOBSITE INFORMATION: (*Indicates required information) *Name: *Address: *Cross Street: *Phone No.: Permit No.: Tax-Map District: - 1000 Section: b 615 Block: Lot: *BRIEF DESCRIPTION OF WORK(Please Print Clearly) (� ��V n �� (Please Circle All That Apply) *Is job ready for inspection: YES/ Rough in Final *Do you need a Temp Certificate: YES/ N Temp Information (if needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form 90 -37)v } Suffolk County Department of Labor, Licensing & 1� j i Consumer Affairs ' VETERANS MEMORIAL HIGHWAY * HAUPPAUGE,NEW YORK 11788 j r i DATE ISSUED: 10/1/2003 No. 33878-ME ! SUFFOLK COUNTY � Master Electrician License r . This is to certify that SAMY A MOUNAS doing business as •, SUNRUN INSTALLATION SERVICES INC having given satisfactory evidence of competency, is hereby licensed as MASTER ELECTRICIAN in accordance with and subject to the provisions of applicable laws,rules and regulations of the County of Suffolk,State of New York. tf i f Additional Businesses ' NOT VALID WITHOUT DEPARTMENTAL SEAL x $ AND A CURRENT i CONSUMER AFFAIRS ' ID CARD r� j r Acting Commissioner SUFFOLK COUNTY DEPT OF LABOR. LICENSING d CONSUMER AFFAIRS MASTER ELECTRICIAN RAW SAMY A MOUNAS This certifies that the 8'""a'KA'E bearer is duly SUNRUN INSTALLATION SERVICES INC licensed by the U—.r w 0-k.. County of Suffolk 33878-ME 10/01/2003 10/01/2017 _ f AC V CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY) F6/16/2017 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Arthur J.Gallagher Co. PHONE 415-546-9300 IFAI = .415-536-8499 Insurance Brokers off CA.`Inc.License#0726293 E-MAIL 1255 Battery Street#450 San Francisco CA 94111 INSURERS AFFORDING COVERAGE NAIC# INSURERA:Zurich American Insurance Company 16535 INSURED SUNRINC-01 INSURERB:James River Insurance Company 12203 Sunrun Inc. INSURERC: 595 Market Street, Floor 29 San Francisco, CA 94105 INSURER D: INSURER E. INSURER F: COVERAGES CERTIFICATE NUMBER: 1044743040 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION,OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS INSR I ADDLISUBRI TYPE OF INSURANCE POLICY EFF POLICY EXP LTR INSD WVD POLICY NUMBER MM/DD MM/DD LIMITS B X COMMERCIAL GENERAL LIABILITY 000641242 10/1/2016 10/1/2017 EACH OCCURRENCE $1,000,000 CLAIMS-MADE ❑X OCCUR DAMAGE TO RENTED PREMISES Ea occurrence $300,000 MED EXP(Anyone person) $10,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $2,000,000 I $10POLICY 0 JECT PRO F—] LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER Total Policy Limit ,000,000 A AUTOMOBILE LIABILITY BAP915542503 10/1/2016 10/1/2017 COMBINED SI I TGLE LIMIT $ Ea accident 1,000,000 X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED AUTOS AUTOS BODILY INJURY(Per accident) $ HIRED AUTOS NON-OWNED PROPERTY DAMAGE AUTOS Per accident $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ A WORKERS COMPENSATION WC013696002 10/1/2016 10/1/2017 1 PER OTH- A AND EMPLOYERS'LIABILITY YIN WC013696102 10/1/2016 10/1/2017 STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE E L EACH ACCIDENT $1,000,000 OFFICER/MEMBER EXCLUDED? N/A (Mandatory in NH) EL DISEASE-EA EMPLOYEE $1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below EL DISEASE-POLICY LIMIT $1,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,maybe attached If more space Is required) WC013696002-$25,000 Deductible;WC013696102-FL, HI, MA, NJ, NY,OR,VA,WI only.Named Insureds:Sunrun Inc.,Sunrun Installation Services Inc.,Sunrun South LLC,AEE Solar, Inc., Clean Energy Experts LLC,Sunrun Solar Electrical Corporation Evidence of insurance - d , a CERTIFICATE HOLDER CANCELLATIONr a 90. SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DEL VERED IN 53095 Route 25 ACCORDANCE WITH THE POLICY PROVISIONS. Southold NY 11971 AUTHORIZED REPRESENTATIVE , ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD i' Yo K Workers' CERTIFICATE OF STATE I Compensation Board NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1a.Legal Name&Address of Insured(Use street address only) 1b.Business Telephone Number of Insured (805)528-9705 Sunrun Installation Services Inc. 775 Fiero Lane,Suite 200 1c.NYS Unemployment Insurance Employer Registration San Luis Obispo,CA 93401-7904 Number of Insured 50-864264 Work Location of Insured(Only required ifcoverage is specifically limited to 1d.Federal Employer Identification Number of Insured or certain locations in New York State,i.e.,a Wrap-Up Policy) Social Security Number 77-0471407 2.Name and Address of the Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Zurich American Insurance Company 3b.Policy Number of entity listed in box"Ia" Town of Southold WC 0136961-02 53095 Route 25 Southold,NY 11971 3c. Policy effective period 10/01/2016 to 10/01/2017 3d. The Proprietor,Partners or Executive Officers are ❑ included. (Only check box if all partners/officers included) ® all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box "3" insures the business referenced above in box "1a" for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". Will the carrier notify the certificate holder within 10 days of a policy being cancelled for non-payment of premium or within 30 days if cancelled for any other reason or if the insured is otherwise eliminated from the coverage indicated on this certificate prior to the end of the policy effective period?®YES ❑ NO This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend,extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the workers' compensation policy indicated on this form, if the business continues to be named on a permit,license or contract issued by a certificate holder-,the business must provide that certificate holder with a new Certificate of Workers' Compensation Coverage or other authorized proof that the ' business is complying with the mandatory coverage requirements of the New York State Workers' Compensation Law. Under penalty of perjury, 1 certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Kelly Cada (Print name of authorized representative or licensed agent of insurance carrier) Approved by: 06/16/2017 (Signature) (Date) Title: Vice President-Enterprise Support Operations Telephone Number of authorized representative or licensed agent of insurance carrier: 800-382-2150 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-15) www.wcb.ny.gov ITNRK Workers' CERTIFICATE OF INSURANCE COVERAGE ATE Compensation UNDER THE NYS DISABILITY BENEFITS LAW Board PART I.To Be completed by Disability Benefits carrier or Licensed Insurance Agent of that Carrier 1 a Legal Name&Address of insured(Street address only) !b Business Telephone Number of Sunrun Installation Services Inc. insured (805) 540-7643 775 Fiero Lane, Suite 200 1 c NYS Unemployment insurance Employer Registration Number of San Luis Obispo,CA 93401 Insured Id Federal Employer identification Number of Insured or Social Security number 77-0471407 2. Name and Address of the Entity Requesting Proof of Coverage 3a Name of Insurance Carrier (Entity Being Listed as the Certification Holder) MUTUAL OF OMAHA 3b Policy Number of entity listed in box"la'; Town of Southold GMNY6X007P07-0001 53095 Route 25 3c Policy effective period, Southold,NY 11971 3/15/2017— 3/15/2018 4.Policy covers: a. X All of the employers employees eligible under the New York Disability Benefits law b. Only the following class or classes of the employer's employees Under penalty of perjury,I certify that I am authorized representative or licensed agent of the insurance career referenced above and that the named insured has NYS Disability insurance coverage as described above Date Signed 6/16/2017 BY Waga ;Za&l2 Signature of carrier's authorized representative(currently on file with DB Bureau) Tel No (914-591-7111) Title DISABILITY ADMINISTRATOR IMPORTANT if box'4a'is checked,and this form is signed by the insurance camer'h authorized representative or NYS L icensed insurance Agent of that camer, This certificate is Completed Mail it directly to the certificate holder. If box-4b-is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd 8 of the Disability Benefits Law.It must be mailed for completion to the Workers'Compensation Board,DB Plans Acceptance Unit,20 Park Street,Albany,New York 12207 PART 2_ _ TO BE COMPLETED BY NYS WORKER'S COMPENSATION BOARD(Only if box"b"of Part'_has been checked STATE OF NEW YORK WORKERS'COINIPENSATiON BOARD According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability Benefits Law with respect to all or his/her employees. Date Signed By (Signature ofNYSI%Vorkers'Compensation Board Employees) .t Tel.No ( 1 Title Please Note Only Insurance carriers licensed to write NYS disability benefits`trikirance policies and NYS licensed insurance agents of those careers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized toiii4sue this form :till, s?�a ilj£F.v `�IXe•r hi DB120.1 (9-15) t ;iL r i�° RTED �,��! "LY �1 I H ,,.LL ��C��S of DATEi Lck, B.P. 3 I EW Y0'K S T AIFEE. & TOWN CODES FEE c � By. ';S REQUIRED _ NOTIFY BUILFIG DEPAR -MFNT AT _ S - a • 765-.802 8 AM TO 4 PM FOR THE � i V i ( I . uhRD FOLLOWING INSPECTIONS: 1. FOUNDATION - TV,/0 REQUIRED , SCc �I.1'll���;df S ":S FOR POURED CONCRETE �xi�� 2. ROUGH - FRAMING & PLUMBING N. 3. INSULATION 4. FINAL - GONSTRUGTION MUST ®� BE COMPLETE POR C.O. OCCUPANCY ALL CONSTRUCTION, SHALL MEET THE tSE IS UNLAWFUL REQUIREMENTS OF THE CODES OF NEG/ YORK STATE. NOT RESPONSIBLE FOR WITHOUT CERTIFICATE DESIGN OR CONSTRUCTION ERRORS. F CCCUPAOlIC� C ELECTRICAL N JVN".CoD-E. �Ta. s r i FUSION 152 S. Broad St 4 �a Lansdale, PA 19446 (215)361-8040 Structural Calculations for the Grecg Manaris Residence PV Installation Date: 6/9/2017 Job Address: 145 Fawn Ln Cutchogue, NY, 11935 Job Number: 211R-145MAN1 Scope of Work These calculations are for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Calculation Index Sheet Description 2 Structural Geometry, Live Load,Snow Load, Wind Load, & Dead Load 3 Roof(1) Framing Check 4 Roof Attachment Check, Seismic Check, &Scope of Work Engineering Calculations Summary Code: 2016 New York State Building Code(2015 IBC& IRC) ASCE 7-10 Snow Load: S= 20 psf Live Load: LL= 20 psf ,Wind: Wind Speed Ult. (V)= 130 mph Exp. = B PV Dead Load: DPV= 3.0 psf ys Sincerely, Penn Fusion Engineering LLC;t';1l ` 5 Andrew D. Leone, P.E. Principal 1 T Engineer:SVL Date:6/9/2017 r; � nin FUSION Job:211R-145MANA g ��! Address: 145 Fawn Lri Cutchogue, NY, 11935 2 of 4 Structrure Geometry: Mean Roof Height,hn = 13 ft Eave Height,he = 8 ft Buiding Length,L = 36 ft Building Width,B = 31 ft Module Area = 20 ftZ Roof Pitch,0 = 31 degrees Live Load: Roof Live Load,Lr = 20.00 psf Equation 4.8-1 Snow Load: Ground Snow Load,pg = 20 psf Fig.7-1 Snow Importance Factor,k = 1 Table 1.5-1 Thermal Factor,Ct = 1.1 Table 7-3 Exposure Factor,Ce = 0.9 Table 7-2 Roof Slope Factor,C5 = 0.72 Figure 7-2c Flat Snow Load,Pf = Sloped Roof Equation 7.3-1 Sloped Roof Snow Loads,Ps = 9.92 psf Equation 7.4-1 Is the width of the roof>20ft? Yes Drift Height,hd = 1.23 ft Figure 7-9 Roof slope for a rise of one,S 1.66 Unbalanced Width = 4.24 ft Fig 7-5 y = 17 pcf Equation 7.7-1 Unbalanced Snow Load = 25.77 psf Fig 7-5 Wind Load: Basic Wind Speed(3s-gust),V = 130.0 mph Figure 26.5-1A Building Occupancy Category = 2 Table 1.5-1 Exposure Category = B Sec 26.7.3 Topographic Factor,Kzr = 1.00 Equation 26.8-1 Adjustment Factor,A = 1.00 Figure 30.5-1 Edge Zone,a = 3.10 ft Figure 30.5-1 Uplift(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30 = -28.90 -34.00 -34.00 Figure 30.5-1 Pnet=0.6 X X x Kzr x Pnet3o) _ -17.34 -20.40 -20.40 Equation 30.5-1 Downward(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30 = 27.00 27.00 27.00 Figure 30.5-1 Pnet=0.6 x A x Kzr x Pnet3o = 16.20 16.20 16.20 Equation 30.5-1 Dead Load: Roof1. Roof Walls-Exterior Composition Shingle 3.0 psf Wood n 5.0 psf 5/8 OSB Sheathing 2.0 2x4 Studs @ 16" 2.0 2x8 Rafter @ 16"OC 2.0 Gypsum 3.0 Misc.(Ceiling,Insulation,etc.) 1.0 Misc.(Insulation,etc.) 2.0 PV System,Ppv 3.0 Total Roof DL= 11.0 psf Total Wall DL= ; '12.0 psf i r Engineer:SVL i Date: 6/9/2017 FUSION Job: 211R-145MANA Address: 145 Fawn Ln Cutchogue, NY, 11935 3 of 4 Roof(1)Framine Check: Roof Framing = 2x8 Rafter @ 16"OC Timber Species = Doug Fir-Larch#2 Max Beam Span = 15.33 ft b = 1.5 In d = 7.25 in Moment of Inertia,Ix = 47.63 in Section Modulus,Sx = 13.14 in3 Bending Stress,Fb = _ 900 psi Elastic Modulus,Emm = 580000 psi ° CD(Wind) CD(Snow) CLS CM Ct Wood Adjustment Factors: 1.60 1.15 1.00 1.00 1.00 CL CF Cfu G Cr 1.00 1.20 1.00 1.00 1.15 PV Tributary Width,Wpv = 2.75 ft PV Tributary Length,Lpv = 4.0 ft PV Tributary Area,At = 11.0 ftZ PV Dead Point Load,PD=Ppvx At = 28 Ib Roof Distributed Load,wDL = 9 plf Load Case: 0.6DL+0.6W (CD=1.6) Roof Zone = 1 Pup=Pnet x At+0.6 x PD x c05(0) = 174 Ib Mb(wind—up) = 932 lb-ft Fb'(wind)=Fb XCD XCLS XCM XCt XCL XCF XCfu XG XCr = 1987 psi Mallowable=Sx X Fb'(wind) = 2176 Ib-ft > 932 OK Load Case: DL+0.6W (CD=1.6) Pdown=Pnetx At+PD x COS(6) = 206 Ib Mb(wind_down) = 1567 lb-ft Fb'(wind)=Fb XCD XCLS XCM XCt XCL XCF XCfu XG XCr = 1987 psi Mallowable=Sx x Fb'(wind) = 2176 Ib-ft > 1567 OK Load Case: DL+0.75(0.6W)+0.755 (CD=1.6) Roof Snow Distributed Load,wSL = 13 plf Psnow=Ps x At = 94 Ib Mb(wind_snow) = 1728 lb-ft Fb'(wind)=Fb XCD XCLS XCM XCt XCL XCF XCfu XG XCr = 1987 psi Mallowable=Sx x Fb'(snow) = 2176 Ib-ft > 1728 OK Load Case: DL+S (CD=1.15) Roof Snow Distributed Load,wSL = 13 plf Psnow=Ps x At = 94'Ib'- Mb(snow) = 1035 lb-ft Fb'(snow)=Fb XCD XCLS XCM XCt XCL XCF XCfu XG XCr = 1428 psi Mallowable=Sx x Fb'(snow) = 1564 Ib-ft > 1035 OK Engineer:SVL Date: 6/9/2017 FUSION N Job:211R-145MANA is ID Address: 145 Fawn Ln 1 Cutchogue, NY, 11935 4 of 4 Rafter Attachments:0.6D+0.6W(Zone 21 Puplift=At x Pnet = 207 Ib Connector Uplift Capcity per SnapNRack Test Results = 500 Ib > 207 OK 5/16"Lag Screw Withdrawl Value = 266 Win Table 11.2A-NDS Lag Screw Penetration = 2.5 in Allowable Capacity with CD = 1064 Ib > 207 OK Seismic Check: Existing Dead Load: Solar Dead Load: Aroofemstmg = 1116 ftZ Wpanel = 42 lb Wroofexistmg = 8928 Ib NUmpanel = 20 Awallexisting = 1072 ftZ Wpanel_tot = 840 Ib Wwallexistmg = 12864 lb Wbos = 196 lb MOW = 21792 lb Warray = 1036 lb iolncrease=(wtotal+Warray)/Wtotal = 22828 *100%-100% = 4.75% ** 21792 **The increase in weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on applicable building codes,professional engineering inspection and design experience,opinions and judgments.The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced In the stamped plan set and were made according to generally recognized structural anlaysis standards and procedures. g n FUs10 n e e r a ng 152 S. Broad St E n Lansdale PA 19446 g i (215)361-8040 June 09, 2017 Subject: Structural Certification for Proposed Residential Solar Installation. Job Number: 211R-145MAN1; Plan Set: Rev A, Dated 6/7/17 Client: Greg Manaris Address: 145 Fawn Ln, Cutchogue, NY, 11935 Attn:To Whom It May Concern A field observation was performed to document the existing framing of the above mentioned address. From the field observation,the existing roof structure was observed as 1 layer Composition Shingle roofing over roof plywood supported by 2x8 Rafter @ 16" OC. The roof is sloped at approximately 31 degrees and has a max rafter span of 15'4" between supports. Design Criteria: • 2016 New York State Building Code (2015 IBC& IRC) • Basic Wind Speed Vult= 130 mph (Vasd= 101 mph), Exposure B • Ground Snow Load = 20 psf Our analysis is based on the information provided by Sunrun Inc. and is isolated only to the areas where the modules are intended to be placed. After review of the field observation report, the existing roof framing supporting the proposed solar panel layout has been determined to meet or exceed the requirements based on our structural capacity calculations in accordance with applicable building codes. Therefore, no structural upgrades are required. If you have any further questions on the above for mentioned, please do not hesitate to call. Sincerely, F NE Penn Fusion Engineering LLC �P� '� — k N� s4 mfJ1 Andrew D. Leone, P.E. . T` �aA Q8i693 Principal ,Q���S$�O�p, SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION• SYSTEM SIZE:6600W DC,6000W AC • ALL WORK SHALL COMPLY WITH 2014 NEC,2015 IBC,MUNICIPAL CODE,AND SE SERVICE ENTRANCE SOLAR MODULES PV-1 0 COVER SHEET • MODULES:(20)LG ELECTRONICS LG330N1 C-A5 ALL MANUFACTURERS'LISTINGS AND INSTALLATION INSTRUCTIONS RAIL PV-2 0 SITE PLAN • INVERTER(S): • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2014 NEC (1)ABB PVI-6000-OUTD-US-A(240 V) • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2014 NEC Mp MAIN PANEL PV-3 0 LAYOUT • RACKING:SNAPNRACK SERIES 100 UL,FLASHED L FOOT • PHOTOVOLTAIC SYSTEM IS UNGROUNDED NO CONDUCTORS ARE SOLIDLY PV-31 ATTACHMENT DETAIL SEE PEN D01 GROUNDED IN THE INVERTER SYSTEM COMPLIES WITH 690 35 • (1)ABB RS1-1PN6-MC4 RAPID SHUTDOWN • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703 SP SUB-PANELPV-4 0 ELECTRICAL • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741 STANDOFFS& FOOTINGS PV-4 1 ELECTRICAL CALCS • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703 • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690 31(G) LC PV LOAD CENTER ® CHIMNEY PV-5 0 SIGNAGE • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT • 10 45 AMPS MODULE SHORT CIRCUIT CURRENT a ATTIC VENT • 16 32 AMPS DERATED SHORT CIRCUIT CURRENT(690 8(a)&690 8(b)) SM SUNRUN METER - � FLUSH ATTIC VENT PM DEDICATED PV METER o PVC PIPE VENT INVERTER(S)WITH pF Nay INV INTEGRATED DC ® METAL PIPE VENT 4E y DISCONNECT AND AFCI ® T-VENT �� `O�MfiN/Cl��f AC AC DISCONNECT(S) ° R R (� _ SATELLITE DISH + a 7n ODC DISCONNECT(S) ® FIRE SETBACKS yU'� V �I O . 081693 A'90F CB COMBINER BOX HARDSCAPE E$$16 —I INTERIOR EQUIPMENT —PL— PROPERTY LINE L J s u n ru n SHOWN AS DASHED SCALE NTS A AMPERE AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER 54139-ME AZIM AZIMUTH VICINITY MAP COMP COMPOSITION 15CHARLO"EAV HICK IUENY11801 DC DIRECT CURRENT PHONEW&S aU87 (E) EXISTING FAx fiaSxfie�mz EXT EXTERIOR CUSTOMER RESIDENCE FRM FRAMING GREG MANARIS INT INTERIOR ro LBW LOAD BEARING WALL 145 FAWN LN,CUTCHOGUE, L6,7,7' Ln MAG MAGNETIC NY,11935 011i � " MSP MAIN SERVICE PANEL (N) NEW TEL(917)567-8550 APN0 7000103000400023000 Hp{1 Ln NTS NOT TO SCALE PROJECT NUMBER Trader L!1' tI _— -'_. OC ON CENTER 211R-145MAN1 PRE-FAB PRE-FABRICATED DESIGNER PA PSF POUNDS PER SQUARE FOOT 303 942 8091 PV PHOTOVOLTAIC STEPHEN DONAHUE Y v prpP)y`r I n f Rush S1 TL TRANSFORMERLESS - TYP TYPICAL DRAFTER t1B"�n 145 Fawn Lana _ V VOLTS STEPHEN DONAHUE N II S p r' ' REV NAME ASS DATE COMMENTS SHEET -,Uk Ln �r�ne COVER SHEET A -j,1bum(h m REV A 6/7/2017 _ <, S PAGE PV-1.0 SITE PLAN-SCALE=3/64" 1101, TRUE TRUE MAG PV AREA SITE PLAN DETAIL-SCALE=1/64"=1'-0" AZIM AZIM (SQFT) ® AR-01 31" 168° 180° 368 8 P� f d as f ° (E)POOL C SOF NeM Y - .–w—d�-s-a-�_- =:.u:�v>a.. ._-c.`,=��:ye�•TM. - =-r.^' - -- r hP.vi�4.�W'C X51 uj PL y� T a (E)GATE 081693 <<.� MP ] d ° (E)FENCE A9QFESS1dN�� a a SE O SM INV a 0 n 1 FIRE SETBACKS sunrun (18"TYP) a 54139-ME d 150HARLOT EAVE H—VILLENY11- PHONE W5 W U.7 FAX 0452682022 a (N)(1)ABB RAPID o a n ° CUSTOMER RESIDENCE SHUTDOWN DISCONNECT d GREG MANARIS 145 FAWN LN,CUTCHOGUE, NY,11935 (N)ARRAY AR-01 °a c TEl(817)557-8550 APNq 700D703000400023000 ° PROJECT NUMBER n 211 R-145MAN 1 (E)RESIDENCE d DESIGNER 3039428097 STEPHEN DONAHUE ° DRAFTER o _ STEPHEN DONAHUE d SHEET FAWN�pNE SITE PLAN REV A 6/7/2017 PAGE PV-2.0 ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF FRAME FRAME TYPE FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA _ EXPOSURE MATERIAL SIZE SPAN SPACING ZONE SPAN OVERHANG MODULES: AR-01 COMP SHINGLE FLASHED L FOOT SEE PEN D01 SINGLE STORY ATTIC WOOD RAFTER 2 X 6 15'=4" 16" N/A 4'-0" 2'-6" LG ELECTRONICS LG330N1 C-A5 MODULE DIMS: D7-AR-01-SCALE:1/8"=V-0" 66 38"x 40"x 1 57" PITCH:31* MODULE CLAMPS: AZIM:168" Portrait 5 9"-15 7" ® Landscape 0"-4 7" MAX DISTRIBUTED LOAD:3 PSF SNOW LOAD:20 PSF WIND SPEED: 130 MPH 3-SEC GUST LAG SCREWS: 5/16"x3 5" 2 5"MIN EMBEDMENT NOTE: INSTALLERS TO VERIFY RAFTER _ SIZE,SPACING AND SLOPED SPANS,AND NOTIFY E 0 R OF ANY DISCREPANCIES BEFORE PROCEEDING PENETRATION SPACING: STAGGER N'�'OF NEyyY 33,_9„ 3,_y„— y Pp0 ME v7�(pg� 2'-3" ^� to 4'TYP — G— I O N s n le- -ro -li!� . 3'-2" 54139-ME " I 15O LOT EAVE HICX-E NY 11801- PHONE805540548I FAX fiA52fifi 2022 CUSTOMER RESIDENCE GREG MANARIS 145 FAWN LN,CUTCHOGUE, NY,11935 TEL(917)567-5550 APN N 1000103000400023000 PROJECT NUMBER 211 R-145MAN 1 DESIGNER 303 942 8091 STEPHEN DONAHUE DRAFTER STEPHEN DONAHUE SHEET LAYOUT REV A 6/7/2017 PAGE PV-3.0 STEP 3 'PLACE L FOOT ON TOP OF NOTES FLASHING AND TIGHTEN NUT 5/16"LAG BOLTS MUST EMBED 2 5"INTO ROOF SNAPNRACK STRUCTURAL MEMBERS/RAFTERS STEP 2 SLIP FLASHING OVER L COMPOSITION L FOOT 5/16"S S FLANGE NUT TORQUE ALL 5/16"HARDWARE TO THE FOLLOWING FOOT BASE AND UNDER ROW OF CAN BE MOUNTED IN -SILVERS S 10-16 FT-LBS SHINGLES ABOVE , ANY ORIENTATION -BLACKS S 7-9 FT-BLS 5/16"X 1"(OR 1 25") RAILS CAN MOUNT TO EITHER SIDE OF L FOOT SNAPNRACK S.S BOLTAND SPLIT (UPSLOPE VS DOWNSLOPE) CHANNELNUT WASHER ® 5/16"S S LAG SCREW WITH FLAT WASHER,2 5"MINIMUM SNAPNRACK EMBEDMENT IS STANDARD STANDARD RAIL STEP 1 BOLT L FOOT BASE TO ROOF WITH SNAPNRACK COMPOSITION LAG BOLT ROOF FLASHING ROOF DECKING TYP SNAPNRACK L FOOT BASE s u n r u n 0 54139-ME 15CH 1.0 TEAS HIC-MENY11801 PHONM559OW COMPLETED FAXB1520.. ROOF DECKING TYP INSTALLATION CUSTOMER RESIDENCE GREG MANARIS 145 FAWN LN,CUTCHOGUE, NY,11935 FLASHED L FOOT MOUNTING POINT FOR USE ON OF NEW Y TEL(977)5878550 APNp 1000703000000023000 RAFTER TYP COMPOSITION ROOF SURFACES WITH LOW TO y P�s���MBN�O�09fi PROJECT NUMBER MODERATE TILT * a to 211R-145MAN1 RAILS CAN BE LEVELED UP TO 3"USING UP TO TWO — a ^' ui' DESIGNER 303 942 8091 LEVELING SPACERS AS SHOWN IN"SERIES 100 RAIL 7-. 11 2� STEPHEN DONAHUE LEVELING" �FOp9 081693 Ay��� DRAFTER ' OFg$510a STEPHEN DONAHUE SHEET ATTACHMENT DETAIL REV A 6!712017 PEN DETAIL 01, FLASHED L FOOT TO RAFTER PAGE - = PV-3.1 - 120/240 VAC - SINGLE PHASE - - - SERVICE OMETER# M PSEGLI 99478038 UTILITY ACCOUNT#9624077803 GRID SUPPLY SIDETAP EXISTING 200A MAIN BREAKER EXISTING 225A (N)LOCKABLE MAIN _ BLADE TYPE (N)LOCKABLE (N)SUN RUN ABB PVI-6000 -A JUNCTION BOX ^- PANEL FUSED BLADE TYPE (240 V) OR EQUIVALENT (1)RSD 1 1 RAPID FACILITY .-.� 5 4 AC DISCONNECT 4 CENTRON 4G -4 6000 WATT INVERTER 3 2 SHUT DOWN DEVICE, 1 PV MODULES LOADS AC DISCONNECT METER NEMA 4X,600V LG ELECTRONICS LG330NlC-A5 A� (20)MODULES (1)STRING OF(10)MODULES ^' -- aRs •� •-- - GFPD (1)STRING OF(10)MODULES > �r-f.�3�c.: - �„_r,,;a-".c.,;4.�,yr..�»+p�r 35A FGS�- SQUARED 250V METER SOCKET - - LOAD RATED DC _ • •• '- '�`_'SQUARE D�� DU222RB 125A CONTINUOUS& 3R,60A,2P 240V METER DISCONNECT WITH AFCI, • "D222NRB RAPID SHUTDOWN 3R,60A 120/240VAC 200A,FORM 2S COMPLIANT 120/240VAC NOTES TO INSTALLER: CONDUIT SCHEDULE 1 409 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE NEUTRAL GROUND # CONDUIT CONDUCTOR 2 CONNECT SYSTEM VIA INSULATION PIERCING ON SUPPLY SIDE OF MAIN BREAKER IN MAIN PANEL ENCLOSURE CONDUCTORS ARE FIELD INSTALLED 1 NONE (4)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER 3 CONNECT THE RAPID SHUTDOWN SIGNAL CIRCUIT CONNECTORS PER s u n r u n (2)10 AWG PV WIRE MANUFACTURER SPECIFICATION 2 NONE NONE (1)6 AWG BARE COPPER 4 SPLICE THE 14 AWG THHN/THWN-2 CONDUCTORS FOR RAPID SHUTDOWN (2)18 AWG SIGNAL CIRCUIT SIGNAL CIRCUITS INTO 18 AWG CONDUCTORS WITHIN TC-ER CABLE AT THE WITHIN TC-ER JUNCTION BOX 54139-ME (2)10 AWG THHN/THWN-2 5 PARALLEL INPUTS ON(INV7)ER MFG INSTRUCTIONS 3 1"PVC OR EQUIV NONE (1)10 AWG THHN/THWN-2 NaNEBB0554051A B NICKSVILLE NY 11801 (2)14 AWG THHN/THWN-2 FMM2682022 SIGNAL CIRCUIT 4 1"PVC OR EQUIV (2)8 AWG THHN/THWN-2 (1)10 AWG THHNrrHWN-2 (1)8 AWG THHN/THWN-2 CUSTOMER RESIDENCE 5 1"PVC OR EQUIV (2)6 AWG THHN/THWN-2 (1)6 AWG THHN/THWN-2 (1)B AWG THHNrrHWN-2 VF N$yy GREG MANARIS Y 145 FAWN LN,CUTCHOGUE, CO MEhI�. 0 NY,11935 * T TEL(917)567-BSM APN 0 1000103000400023000 MODULE CHARACTERISTICS — m PROJECT NUMBER LG ELECTRONICS y 2 211R-145MAN1- LG330N1C-A5 330 W OPEN CIRCUIT VOLTAGE 40 9 V SFO 081693 �t� DESIGNER 303 942 8091 MAX POWER VOLTAGE 33 7 VOFLESS IO�P STEPHEN DONAHUE SHORT CIRCUIT CURRENT 10 45 A • DRAFTER SYSTEM CHARACTERISTICS-INVERTER 1 STEPHEN DONAHUE SYSTEM SIZE 6600 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE 455 V ELECTRICAL SYSTEM OPERATING VOLTAGE 337 V MAX ALLOWABLE DC VOLTAGE 600 V _ SYSTEM OPERATING CURRENT 19 6 A REV A 6/7/2017 SYSTEM SHORT CIRCUIT CURRENT 26 13 A PAGE - PV-4.0 System Information 6 6 kW DC Photovoltaic System (20)LG Electronics LG33ON1C-A5,ABB'PVI-6000-'OUTD-US-A(240 V) DC Wire Sizing Max Circuit Current=(Module Is c)x(High Irradiance)[69O 8(A)(1)]x(Continuous Load)[690 8(B)(1)]_ 10 45A x 1 56=16 3A Adjusted Conductor Ampacity=(High Temp)[Table 310 16]x(Conduit FdI)[Table 31O.15(B)(2)(a)]x (Conductor Ampacity)[Table 310 16]_ O76xO.8x4OA=2432A Terminal Rating[11O 14(C)]= 10 AWG,60°C Rated=3OA _ 24 32A<3OA—> Adjusted conductor ampacity governs conductor sizing. 16 3A<24 32A—.10 AWG Ampacity OK Therefore 10 AWG is sufficient ��pF NEy Y AC Wire Sizing y P pOM 6 0 O¢ efi Max AC Output Current=(Max Inverter Output)x(Continuous Load)[21O 19(A)(1)] 26Ax125=35A ) Adjusted Conductor Ampacity=(High Temp)[Table 310 16]x(Conduit FdQ[Table 310 15(B)(2)(a)]x )J�� (Conductor Ampacity)[Table 310 16] 0 96 x 1 x 55A=38AAO 081693/0 F Terminal Ratmg[11O 14(C)]= O9pFE$stDNP� 8 AWG,60°C Rated=4OA 38AA<4OA--> Adjusted conductor ampacity governs conductor sizing. 35A<38 4A—.8 AWG Ampacity OK Therefore 8 AWG is sufficient Inverter Overcurrent Protection s u n ru n (Inverter Max Current)x(Continuous Load)_ 28 A x 125=35 A—>35 A Overcurrent Protection 54139-ME System Characteristics Operating Voltage =(Module VMP)x(#Modules/String)= 15C L077EAVE HICKWIUENY11801 PH.EOOSWc 67 33 7 V x 10=337 V F0.0412662022 Max Open Circuit Voltage ={[((Temp Coef VOC)x(VOC))/100]x[Low Temp-STC Temp]+VOC} CUSTOMER RESIDENCE x(#Modules/String)_ {[(-0 27%/°C x 40 9 V)/100]x 1-17°C-25'C]+40 9 V}x 10=455 38 V GREG MN LN,C Operating Current =(Module IMP #Strings)- 145 FAWN LN,CUTCHOGUE, ( 9 )- NY,11935 98Ax-2=196A Short Circuit Current=1 25 x(Module Isc)x(#Strings) TEL(917)667-855 APNN 100D10WW400D23000 125 x 10 45 A x 2=26 13A PROJECT NUMBER 211 R-145MAN 1 DESIGNER 303 942 8091 Assumptions STEPHEN DONAHUE Max Ambient Temperature=32°C DRAFTER Low Temperature=-17°C STEPHEN DONAHUE All conductors are 90°C rated copper Roof top temperature_adder=22°C SHEET Attictemperature'adder=7°ce_; -_____ ELECTRICAL CALCS REV A 6!7/2017 PAGE PV-4.0 INVERTER 1 - _ NOTES AND SPECIFICATIONS e ® In .�-. • • • • •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2016 AND &YVARNIN.G. - �. i ® ® • NEC 2014 ARTICLE 110 21(B)UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED I, 7 .• , r '• •• 19 6 BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ I ® p ■ ® •• •® • 337 0 •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS ELECTRICAL SHOCK HAZARD "' y "�" • 455 t .LA13ELLS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING LABEL LOCATION •• 26 13 METHOD AND SHALL NOT BE HAND WRITTEN,UNLESS PORTIONS OF LABELS OR INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,AT EACH TURN,ABOVE AND MARKINGS ARE VARIABLE,OR THAT COULD BE SUBJECT TO CHANGES,SHALL DO NOT TOUCH TERMINALS. BELOW PENETRATIONS,ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS LABEL LOCATION BE PERMITTED TO BE HAND WRITTEN AND SHALL BE LEGIBLE TERMINALS ON LINE AND LOAD PER CODE(S)CEC 2016 690 31(G)(3),690 31(G)(4),NEC 2014 69031(G)(3), INVERTER(S),DC DISCONNECT(S) •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT 690 31(G)(4),NEC 2011 690 31(E)(3),690 31(E)(4),IFC 2012 6051114 PER CODE(S)CEC 2016 690 53,NEC 2014 690 53,NEC INVOLVED SIDES MAY BE ENERGIZED IN 2011 69053 •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535 4-2011,PRODUCT SAFETY THE OPEN POSITION ® ® ® ] •SIGNS AND DO NOT COREEXISTING MANUFACLS,UNLESS TURER LABELS SE D LABEL LOCATION _— INVERTER(S),AC DISCONNECT(S),AC COMBINER PANEL OF APPLICABLE) PER CODE(S)CEC 2016 690 17(E),NEC 2014 690 17(E), I tm . ., •; ri�s> - .. NEC 2011 69017(4) k: I ©`O r © r+;��S h� 4y,0 M8 7ClQ�F &WA R N I N G LABEL LOCATION UTILITY SERVICE ENTRANCE/METER,OR AS REQUIRED BY LOCAL AHJ c- i ELECTRICAL SHOCK HAZARD PERCODE(S)CEC2016 69012,NEC69056,NEC2014 69012,NEC69056, BUILDING SUPPLIED BY UTILITY m W IFC 2012 605 m c; IF GROUND FAULT IS INDICATED GRID AND PHOTOVOLTAIC ALL NORMALLY GROUNDED _ SYSTEM �9oF�ssloN°` CONDUCTORS MAY BE ' ' 'OR UNGROUNDED AND ENERGIZED ` LABEL LOCATION LABEL LOCATION AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INVERTER(S),ENPHASE ENVOY ENCLOSURE(IF INTERCONNECTION S u n r u n APPLICABLE) PER CODE(S)CEC 2016 690 54,NEC 2014 690 54,NEC PER CODE(S)CEC 2016 690 5(C),NEC 2014 690 5(C), 2011 69054 NEC 2011 690 5(C) PV SYSTEM DISCONNECT &WARNING &WARNING 54139-ME ELECTRICAL SHOCK HAZARD DUAL POWER SUPPLY THE DC CONDUCTORS OF THIS SOURCES:UTILITY GRID 15CHARLOTTEAVE HICKS ENY11e01 PHOTOVOLTAIC SYSTEM ARE PHONE e0s sa0549] AND PV SOLAR ELECTRIC FAx ens 2se xon UNGROUNDED AND MAY BE ENERGIZED SYSTEM CUSTOMER RESIDENCE LABEL LOCATION LABEL LOCATION - GREG MANARIS INVERTER(S),DC DISCONNECTS UTILITY SERVICE METER AND MAIN 145 FAWN LN,CUTCHOGUE, PER CODE(S)CEC 2016 690 35(F),NEC SERVICE PANEL LABEL LOCATION NY,11935 2014 690 35(F),NEC 2011 690 35(F) PER CODE(S)CEC 2016 705 12(D)(3), POINT OF INTERCONNECTION NEC 2014 705 12(D)(3),NEC 2011 (PER CODE NEC690 56(B),NEC705 10,225 37,230 2(E)) TEL(917)5678550 APN a 1000103000400023000 705 12(D)(4) w, �± PROJECT NUMBER —&WARNINGp1 ' &WARNING 211R-145MAN1 INVERTER OUTPUT CONNECTION PHOTOVOLTAIC SYSTEM DESIGNER 3039428091 DO NOT RELOCATE THIS COMBINER PANEL STEPHEN DONAHUE OVERCURRENT DEVICE DO NOT ADD LOADS DRAFTER LABEL LOCATION LABEL LOCATION STEPHEN DONAHUE ADJACENT TO PV BREAKER OF PHOTOVOLTAIC AC COMBINER OF APPLICABLE) APPLICABLE) SHEET PER CODE(S)CEC 2016 PER CODE(S)CEC 2016 SIGNAGE 705 12(1))(2)(3)(b),NEC 2014 70512(D)(2)(3)(c),NEC 2014 705 12(D)(2)(3)(b),NEC 2011 705 12(D)(7) 705 120D)(2)(3)(c),NEC 2011 705 12(D)(4) _ REV A 6!7/2017 z _ _ PAGE PV-5.0 SolarInverters ABB -string inverters 000 •00' to 6kW a I AU Designed for residential and small The wide input voltage range makes Highlights commercial PV installations,this the inverter suitable for low-power — Single-phase and three-phase output inverter fills a specific niche in the installations with reduced string size. grid connection ABB product line to cater for those The transformerless operation offers — Wide input-voltage range for installations producing between 5kW high performance efficiencies of up to increased stringing flexibility and 20kW. 97.1 percent. — The high-speed and precise MPPT Free remote monitoring capability is algorithm offers real-time power This inverter includes dual input available with every installation.This tracking and improved energy section to process two strings with enables homeowners to view their harvesting independent Multiple Power Point energy production and offers installers — Outdoor NEMA 4X rated enclosure Tracker(MPPT). a proactive and economic way of for unrestricted use under any The high-speed and precise MPPT maintaining and troubleshooting the environmental conditions algorithm offers real-time power system. — Integrated DC,disconnect switch tracking and energy harvesting. in compliance with international Flat efficiency curves ensure high- Standards(;.S Version) efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental �'^� conditions. ® Q Power and productivity � ) for a better worldTM B'HU Additional highlights - RS-485 communication interface(for' connection to laptop or data logger) - Available with the optional VSN300 1 ARID - - Wifi Logger Card for easy and w j affordable wireless monitoring " - Compliant with NEC 690.12 when m x- used with ABB`s Rapid Shutdown I •, 2 i .�_ `+ '} device g �: - °; i �.: • " m - Comes standard with DC Arc Fault m Circuit Interruptor(AFCO to comply , . .� i-•-;----==•`""."`--�� with NEC 690.11 Technical data and types Type code PVI-5000-OUTD-US PVI-6000-OUTD-US General Specifications i Nominal output power 5000W 6000W Maximum output power 5000W 6b00w .. ... ; Rated grid AC voltage 208V 240V 277V 208V 240V 277V i Input side(DC) Number of independent MPPT channels 2 Maximum usable power for each channel 4000w Absolute maximum voltage(Vmax) _ 600V Start-up voltage(Vstart) 200V(adj. 120-350) Full power MPPT voltage range 145-530V 175-530V Operating MPPT voltage range 0.7 x Vstart-580V(>_90V) Maximum current(ldcmax)for both MPPT in parallel 36A Maximum usable current per channel 18A Maximum short circuit currentper channel 22A Number of.wire landing.terminals per chan_nel _ 2 Pairs Array wiring termination Terminal block,pressure clamp,AWG20-AWG6 ?Output side(AC) Grid connection type 10/2W Split-0/3W 10/2W 10/2W Split-0/3W 10/2W Adjustable voltage range.(Vmin-Vmax) 183 228V _ 2211264V 244-304V 183-226V _ 211-264V 244-304V Grid frequency 60Hz Adjustable grid frequency range - 57-60.5Hz Maximum current(I°°,mom)A� 27A _ 23A 20A 30A 28A 24A Power factor >0.995(adjustable to±0.8) Total harmonic distortion at rated power <2% 36.25 4 / 36.5 A / 31.75 A / 36.25 A / 36.5 A / 31.75 A / Contributory fault current' pk pk pk Pk pk Pk 25 63A�- 25.81 A� 22 45A 25 63A� 25.81 A� 22.45Ar� Grid wiring termination type Terminal block,pressure clamp,AWG20-AWG4 Input Reverse polarity protection Yes Over-voltage protection type Vanstor,2 for each channel PV array ground fault detection Pre start-up R and dynamic GFDI(requires floating arrays) I-Output - 1 Anti-islanding protection Meets UL1741 /IEEE_1547 requirements Over-voltage protection type Varistor.2(L,-L2/L,-G) Maximum AC OCPD rating 35A 30A 25A • 40A 35A 30A Efficiency j Maximum efficiency 97.1% CEC efficiency 96% 96.5% 965% 96% 965% 96.5% User interface Graphic display ;Operating performance ) Stand-by consumption tt:; <8W,,„s <8Wus Nighttime consumption <0-6w.111 <0.6W , (Communication User-interface ; .{t, 16 characters x 2 lines LCD display Remote monitoring(1 xRS485 inch)% VSN700 Data Logger(opt),VSN300 Wifi Logger Card(opt.) 'Environmental ; Ambient air operating temperature-range -13°F to+140°F(-25°C to+60°C) 13°F to+140°F(-25°C to+60°C)with deratjng above 122°F(50°C) - Ambient air storage temperature range -40°F to+176°F(-40°(j to+8o-b) -40°F to+176°F(-40°C to+80°C) Relative humidity _ 0-100%RH condensing 6-100%RH condensing Acoustic noise emission level <50 db(A).@1 m_ <50 db(A)@1 m_ Maximum operating altitude without derating 6560ft(2000m) 6560ft(2000m) i'f 2 ABB solar inverters Product flyer for PVI-5000/6000-TL-OUTD r Block diagram of PVI-5000/6000-TL-OUTD ------+---------i-----------------i-----i --------------------------------------------------------------------------- -• IN11(+) i MPPr1 INVERTER i +, (DGDC) BULK CAPS (DC/AQ+ + + + UNE GRIDPARALLEL , FILTER RELAY' , 1 �e— LI IN1 IN1 INI IN1 (y ,IN7 IN1 N 4 DC I AFDI -------------r- ----c--- I I I I MPPT2 T J I 1 I Rx/DCl I I ,IN2 --I RESIDUALCURRENT I 1 IN2 IND IN2 IN2 1 W2 i DETECTION _ 1 y - - - - RSOBS 1 I � IN220 i , , -- a +T/R , `i d .__r_______ _ _____i____!___________� 'DCI �� DSAPC RTN WIRING BOX - i I 1E$ CONT0. . CONTR +' REMO7ECONTROL'. ❑ 0. GROUND b I1P � I FAUU i OETFLRON �_ @ ALARM ..._......_,�..� ,�.._..-._.�.... NC CONTROL ORNR° N O C -Rem m IAmmonrotavabblew-Ave1$on PVI-5000/6000-OUT°-US ( PVI-5000/6000-OUTD-US 480 r 97 1 I } •i 99 :I {{ ;J 400 95,9 97 95,6 . 96 95 i s` 345 MPS9 e ?94,7 lE LU 94 r r ( 941 a ( 99 /• I I 93,8. + 92 —250 Vdc t 300 93,S, Y —345 Vdc . 93, 91 �.-S 480 Vdc 4 2 �, ` 92,9 9191E • 250 92,6 I 0 .10 20 30 40 ,.50 60 70 80 90 100 ii %of Rated Output Power - 10% 20% 30% 50% 75%-- 100%6 1 °%of Rated Output Power Technical data and types Type code PVI-5000-OUTD-US PVI-6000-OUTD-US I Mechanical specifications. j Enclosure rating NEMA 4X Cooling. Natural convection Dimensions H'x W x D 41.4x12.8x8.6 in(1052 x 325 x218 mm) Weight <59.51027.Okg) Shipping weight <781b(35.4kg) Mounting system Wall bracket Bottom:(2)pre-drilled opening for 3/4 inch conduits and concentric markings for 1 inch (both sides)and 1112 inch conduit(DC side only) Conduit connections Sides:(2)pre-drilled opening for 3/4 inch conduits with concentric markings for 1 inch (both sides)and 11h Inch conduit(DC side only) _ •.... Back:(2)concentric markings for 3/4 Inch and 1 Inch conduits DC switch rating(per contact) 25A i 600V I Safety and Compliance 3 Isolation level Transformerless(floating array) Safety and EMC standard '(1L 1741,UL1741SA(draft),IEEE1547,IE5E1547A,C$A-022.2 N. 107.1-01,UL1998 UL 1699B,FCC Part 15 Class B Safety approval CSA�or.TUV. Regional Compliance Rule 21,HECO,NEC 2014 690.11,NEC 2014 690.12 with ABB Rapid Shutdown device 'Available models With DC switch,wiring box and arc fault detector and PVI-5000-OUTD-US-A PVI-6000-OUTD-US-A interruptor All data Is subject to change without notice Product flyer for PVI-5000/6000-TL-OUTD I ABB solar Inverters 3 Support and service For more information please contact ©Copyright 2015 ABB.All rights ABB supports its customers with a your local ABB representative or visit: reserved. Specifications subject to dedicated, global service organization change without notice. in more than 60 countries, with strong www.abb.com/solarinverters ❑M L 7J� regional and national technical partner 'k� CO networks providing a complete range of www.abb.com life cycle services. o N L. r O O Z W W Q LC)Ve� TUhainlanA v Q C us CP us COo 0 Y Y This inverter is marked with one of the m two certification marks shown here(TuV or CSA). Power and productivity �® for a better worldTM Nakaff)RD i� ShapNrack- Lef Solar Mounting Solutions ,- Series 100 Residential Roof Mount System The SnapNrack Series 100 Roof Mount System is engineered to optimize material use, labor resources and aesthetic appeal. This innovative system simplifies the process of installing solar modules, shortens installation times, and lowers installation costs; maximizing productivity and profits. The Series 100 Roof Mount System boasts unique, pre-assembled, stainless steel "Snap- In" hardware and watertight flash attachments. This system is installed with a single tool. No cutting or drilling means less rail waste. It is fully integrated with built-in wire management, solutions for all roof types, one-size-fits-all features, and can withstand extreme environmental conditions. Series 100 is listed to UL Standard 2703 for Grounding/Bonding, Fire Classification and Mechanical Loading. UL 2703 Certification and Compliance ensures that SnapNrack installers can continue to provide the best in class installations in quality, safety and efficiency. Appealing design with built-in aesthetics No grounding lugs required for modules All bonding hardware is fully integrated Rail splices bond rails together, no rail " jumpers required No drilling of rail or reaching for other tools required Class A Fire Rating for Type 1 and 2 modules ti - 7.•,a System Features Include qzw, ?//o Snap in Single Tool Easy No Cutting Hardware Installation Leveling or Drilling Y4P u o Integrated Wire Preassembled Integrated bonding UL 2703 Certified Management hardware Resources snapnrack.com/resources 0 Design snapnrack.com/configurator p where to Buy snapnrack.com/where-to-buy SnapNrack- Solar Mounting Solutions Stainless Bolt with Stainless Steel Bonding Splice Standard Rall Split-Lock Washer 801t with Split- Insert 015-09816 Lock Washer Bonding Adjustable End Clamp Top Bonding Splice Mid Clamp Base Bonding Bonding Adjustable Bonding Channel Nut End Clamp Bottom Channel Nut Stainless Stainless Hardware with Bolt with Bonding Adjustable Split-Lock Washers Split Lock Bonding Mid Clamp Bonding Standard Washer End Clamp zaz-ozos3 Rall Sp1lce Ground Lug 242-02067 242-4015 242-02101 12-6 AWG Copper Wire w Ground Lug Assembly (ONE REQUIRED PER ROW OF i MODULES) i t Universal End Clamp(UEC) Wave �.� UEC Pull Strap _ UEC Wedge Stainless Steel Bolt - "'�'s1°G"•-" with Flat Washer Universal End Clamp 242-02215 Standoff Clamp Assembly - Rubber Serrated StainlessChannel Channel Nut Rain Collar Steel Flange Nut Nut Stainless Serrated Stainless Flange Nut Mill Finish Steel Flange Bolt 92 Degree - Stainless L Foot Flange Standoff Bolt ..Q All Purpose 7u L Foot Mill Finish Standoff Metal Roof Base(1-Hole Mill Finish L Foot Base Assembly Base Shown) Flashing L Foot Base yjJ _ Metal Roof Base Standoff L Foot Base with Flashing with L Foot 242-92057 242-92050 242-02037 SERIES 100 TECHNICAL DATA • 6000 Series aluminum Materials • Stainless steel • Galvanized steel and aluminum flashing .i • Silver and black anodized aluminum Material Finish • Mill finish on select products � ' • Silver or black coated hardware Note.Appearance of mill finish products may vary and change over time. Wind Loads 110 -190 mph (ASCE 7-10) Snow Loads 0 -120 psf Array Pitch 0 - 60 degrees ` i III i� . I # 877-732-2860 p www.snapnrack.com p contact@snapnrack.com ©2016 by SnapNrack Solar Mounting Solutions.All rights reserved '•i' SmpNmd;seiies_100_&odluiL21 LG • • • Life's Good LG NeON-2 LG's new module,LG NeON T"2,adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires ^oveovto aaooua to enhance power output and reliability.LG NeONT""2 DVE E1��s CE6® cell demonstrates LG's efforts to Increase customerlk �s s values beyond efficiency It features enhanced warranty,durability, Intertek %� • �� . performance under real environment,and aesthetic design suitable for roofs Enhanced Performance Warranty •• High Power Output LG NeON'"2 has an enhanced performance warranty Compared with previous models,the LG NeON'""2 The annual degradation has fallen from-0 6%/yr to has been designed to significantly enhance Its output -0 55%/yr Even after 25 years,the cell guarantees 1 2%p efficiency,thereby making It efficient even In limited space more output than the previous LG NeONT"2 modules Aesthetic Roof ® Outstanding Durability of LG NeONTP 2 has been designed with aesthetics in mind, With Its newly reinforced frame design,LG has extended thinner wires that appear all black at a distance the warranty of the LG NeONT'2 for an additional The product may help increase the value of 2 years Additionally,LG NeON"2 can endure a front a property with its modern design load up to 6000 Pa,and a rear load up to 5400 Pa 6 O t A� � o Better Performance on a Sunny Day Double-Sided Cell Structure • LG NeONT"°2 now performs better on sunny days thanks The rear of the cell used in LG NeON'"2 will contribute to to its improved temperature coefficiency generation,just like the front,the light beam reflected from the rear of the module Is reabsorbed to generate a great amount of additional power About LG Electronics LG Electronics is a global player who has,been committed to expanding Its capacity;based on solar energy business as Its future growth engine We embarked on a solar energy source research program in 1985,supported by LG Group's rich experience in semi-conductor,LCD,chemistry,and materials industry We successfully released the first Mono X�series to the market in 2010,which were exported to 32 countries in the following 2 years,thereafter In 2013,LG NeON-(previously known as Mono XO NeON)won"Intersolar Award';which proved LG is the leader of innovation in the industry C LG Ne®N 2 MMMI-3 Mechanical Properties Electrical Properties(STC*) Cells 6x10 Module LG335N1C-A5 LG330N1C-AS LG325N1C-A5 Cell Vendor LG Maximum Power(Pmax) 335 330 325 Cell Type Monocrystallme/N-type MPP Voltage(Vmpp) 341 337 333 Cell Dimensions 161 7 x 161 7 mm/6 inches MPP Current(Impp) 983 98 9.77 c of Busbar 12(Multi Wire Busbar) Open Circuit Voltage(Voc) 410 409 408 Dimensions(L x W x H) 1686 x 1016 x 40 mm Short Circuit Current(Isc) 10.49 1045 1041 66.38 x 40 x 1 57 Inch Module Efficiency 196 193 190 Front Load 60001"a Operating Temperature -40-+90 Rear Load 54001oa Maximum System Voltage 1,000 Weight 18 kg Maximum Series Fuse Rating 20 Connector Type MC4 Power Tolerance(%) 0-+3 Junction Box IP68 with 3 Bypass Diodes *STC(Standard Test Condition)Irradlance 1,000 W/m',Ambient Temperature 25°C,AM 1 5 Cables 1000 mm x 2 ea *The nameplate power output is measured and determined by LG Electronics at its sole and absolute discretion *The Typical change in module efficiency at 200W/m'in relation to 1000W/m2 is-2(y Glass High Transmission Tempered Glass Frame Anodized Aluminium Electrical Properties(NOCT*) Certifications and Warranty Module LG335N1C-AS LG330N1C-A5 LG325N1C-AS Certifications IEC 61215,IEC 61730-1/-2 Maximum Power(Pmax) 247 243 240 UL 1703 MPP Voltage(Vmpp) 31 5 31.2 308 IEC 61701(Salt mist corrosion test) MPP Current(Impp) 783 781 778 IEC 62716(Ammonia corrosion test) Open Circuit Voltage(Voc) 382 381 380 ISO 9001 Short Circuit Current(Isc) 844 841 838 Module Fire Performance(USA) Type NOCT(Nominal Operating CeilTemperature)Irradiance 800W/mlambient temperature 20,C,wind speed lm/s Fire Rating(CANADA) Class C(ULC/ORD C1703) Product Warranty 12 years Output Warranty of Pmax Linear warranty— Dimensions(mm/in) **1)15tyear 98%,2)After 2nd year.055%annual degradation,3)25years 848% e,kl Temperature Characteristics s NOCT 45 t 3°C Pmpp -0 37%/°C Voc -0 27%/°C __.. Isc 0.03%/°C Characteristic Curves 1o0ow � 10 ----- - — - - 800W � 0 V 60OW 5 ` iaaeenan 40OW 20OW 2 Voltage(V) 0 5 10 11 20 15 30 35 40 - 140 120 p 100 80- Pnux s e ao 20 T mpe—m(^e) ao 25 00 North America Solar Business Team Product specifications are subject to change without notice ® LG LG Electronics USAInc Life's Good 1000 Sylvan Ave,Englewood Cliffs,N107632 ti!r• Copyright©2017 LG Electronics All rights reserved Innovation fora Better Ufe 'C i Contact Ig solar�la lge corn 01/0112017 www Igsolarusa coni