Loading...
HomeMy WebLinkAbout41685-Z A,��Gti Town of Southold 6/8/2017 P.O.Box 1179 o 53095 Main Rd 1 �Ot Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 39000 Date: 6/8/2017 THIS CERTIFIES that the building GENERATOR Location of Property: 1305 Bay Haven Ln, Southold SCTM#: 473889 Sec/Block/Lot: 88.4-37 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/31/2017 pursuant to which Building Permit No. 41685 dated 5/31/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ACCESSORY GENERATOR AS APPLIED FOR The certificate is issued to Baer,Nolan of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 41685 06-01-2017 PLUMBERS CERTIFICATION DATED Authorized Signature �U DF TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41685 Date: 5/31/2017 Permission is hereby granted to: Baer, Nolan 1305 Bay Haven Ln Southold, NY 11971 To: install accessory generator as applied for. At premises located at: 1305 Bay Haven Ln, Southold SCTM # 473889 Sec/Block/Lot# 88.4-37 Pursuant to application dated 5/31/2017 and approved by the Building Inspector. To expire on 11/30/2018. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO -ACCESSORY BUILDING $50.00 Total: $235.00 Buildin In ctor Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9,1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. -�I I r I New Construction: Old or Pre-existing Building: (check one) Location of Property: `] 1' A_Qe,,N L� House No. V Street Hamlet Owner or Owners of Property: 401 (�� t ?,&I F, Suffolk County Tax Map No 1000, Section Block Lot Subdivision Filed Map. Lot: Permit No. q 1 b Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: vo� (check one) Fee Submitted: $ Applicant ignature CONSENT TO INSPECTION the undersigned, do(es)hereby state: Owner(s)Names) That the undersigned(is) are)the owner(s) of the premises in the Town of Southold, located at I--.NpS7 which is shown and designated on uffolk County Tax Map as District 1000, Section ,Block ,Lot 11 . That the undersigned(has) (have)filed, or cause to be filed, an application in the Southold Town Building Inspector's Office for the following: That the undersigned do(es)hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property,including any and all buildings located thereon,to conduct such inspections as they may deem necessary with respect to the aforesaid application,including inspections to determine that said premises comply with all of the laws, ordinances,rules and regulations of the Town of Southold. The undersigned, in consenting to such inspections, do(es) so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws, ordinances,rules or regulations of the Town of Southold. Dated: (Signature) Ala L,�,j/ 4-�?44-,e (Print Name) (Signature) (Print Name) SOU��,®l � o Town Hall Annex Telephone(631)765-1802 54375 Main Road y Fax(631)765-9502 P.O.Box 1179 • �Q roger.richert(-)town.southold.ny.us Southold,NY 11971-0959 Q NTY,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Baer Address: 1305 Bay Haven Lane City: Southold St: New York Zip: 11971 Building Permit#: 41685 Section- 88 Block: 4 Lot: 37 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: AS BUILT DBA: License No: SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: "AS BUILT" - "ELECTRICAL SURVEY" - "NO VISUAL DEFECTS" Notes: 20 KW Standby Generator with Auto Transfer Switch. Inspector Signature: Date: June 1, 2017 0-Cert Electrical Compliance Form.xls OE SOUlyolo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) REMARKS: .DATE - / INSPECTOR TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX: (631)765-9502 Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application I Flood Permit Examined ( 20Single&Separate Truss Identification Form Storm-Water Assessment Form �j Contact: Approved ✓ 20�"l 1 Mail to: Disapproved a/c Phone: x 'r D (tLy DbiliNiRd'Inspector MAY 3 1 2011 APPLICATION FOR BUILDING PERMIT BUILDING DEP E Date f`� ,20_q_ TOWN OF SOUTHOLD INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets,of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. 0 (Signature of applicant or name,if a corporation) (Mailing address of applicant) I 1 State whethe applicant 's owner, lessee, agent, architect, engineer,general contractor, electrician, plumber or builder Name of owner of premises ILV, _,J a(wa, (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location ofJand on whiqhxropose4 work will b d� one: WA—t- House Number —SireetJ Hamlet County Tax Map No. 1000 Section %S& Block Lot ��� Subdivision Filed Map No. Lot 2. State existing use and occupancy of premised intended use and occupancy of pr osed construction: a. Existing use and occupancy. b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work ` (Descripti ) C 4. Estimated Cost JA IL400 — Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10.Date of Purchase Name of Former Owner 'fk -4 CO?X 11.Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO--,.Y- 13. Will lot be re-graded?YES N04Will excess fill be removed from premises?YES NO-2-c- 14. OS14.Names of Owner of premises Address_ Phone No. Name of Architect Address Phone No Name of Contractor "huGt Address Phone No. 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO X *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property? * YES NO-X— * IF YES, PROVIDE A COPY. STATE OF NEW YORK) QQ SS.- COUNTY S:COUNTY OF being duly sworn,deposes and says that(s)he is the applicant ame of individual signing c act)above named, (S)He is the w0v1 (Con ctor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief,and that the work will be performed in the manner set forth in the application filed therewith. Sworn to Afore me this day of 20—/;7- - Notary Public GRINKO Signature of Applicant NOTARY PUBLIC STATE OF NEW YORK SUFFOLK COUNTY C.#O1GR$2671 COMM. M.EXP cr u t 03F S��/jyD� ; Town Hall Annex Telephone(631)765-1802 54375 Main Road So6 P.O.Sox 1179 roger.richertOwutg 5olny.us Southold,NY 11971-0959 Wa DING DUARTM EW TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION ' I REQUESTED BY: �=,r j Date: 61m- rI Company Name: ' Name: License No.: Address: 0 • Phone No.: - JOBSITE INFORMATION: (*Indicates required information) *Name: � *Name:+-�Z *Address: *Cross Street: *Phone No.: Permit No.: i Tax-Map District: 1000 Section: Block: Lot: '? E *BRIEF DESCRIPTION OF WORK(Please Print Clearly) I� k__V V (Please Circle All That Apply) *Is Job ready for inspection: ES NO Rough In Dna *Do.you need a Temp Certificate: YES Temp Information(If needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-bequest for lnspecllon Form 31 1� APPRO ED AS NOTED RETAIN STORM WATER RUNOFF DATE:S3l B.P.# `S PURSUANT TO CHAPTER 236 FEE: D BY: OF THE-TOWN CODE. NOTIFY BUILDING DEPART AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED ELECTRICAL FOR POURED CONCRETE INSPECTION REQUIRED 2. ROUGH - FRAMING' & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR ,C:O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES O►- OCCUPANCY OR NEW YORK STATE & TOWN CODE USE IS-UNLAWFUL, REQUIRED AND CONDITIONS Or WITHOUT C_RTI F I , HOLD TO RC Of OCCUPANCY SG T-11) 9 TI1WN TDI STCCS .q n _ _ o r� rK .e: v 5. _E r a u r �s {{ a OIL 4 i lF 4 R � h P 9 e � 6T 1 r f u. iR Aj n < n t. C S iC r ... ... f '.. '... .:..gip...c:. Y «k GENERAV GUARDIAN@ SERIES STANDBY GENERATORS Air-Cooled Gas Engine Generator Sets INCLUDES: Standby Power Rating Model 005887-1 (Aluminum - Gray) - 20 kW 60Hz True Power® Electrical Technology 1v&Lihe LCD Tri'linguaill-," 'ntrdll'- ','Digital Nexus"' Controller 0 Fle6ftonic Governor External Mairi Circuit Breaker, ''System Status &,Maint6nanc`e Interval LED Indicators"and GFCl Duplex Outlet. FSound'Atten dated Enclosure Flexible FubILine Connector EN ERAC' o Composite-Mounting Pad I- Base Fascia Natural Gas or LP Gas Operation 3 Year,Limited Warranty ' C - &S 1 I QU/Ef iEff. UL 2200 Listed LISTED 7 FEATURES • INNOVATIVE DESIGN&PROTOTYPE TESTING are key components 0 SOLID-STATE, FREQUENCY COMPENSATED,VOLTAGE REGULATION. of GENERAC'S success in"IMPROVING POWER BY DESIGN."But it This state-of-the-art power maximizing regulation system is standard on doesn't stop there.Total commitment to component testing,reliability all Generac models. It provides optimized FAST RESPONSE to changing testing,environmental testing,destruction and life testing, plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by to applicable CSA,NEMA,EGSA,and other standards,allows you to electronically torque-matching the surge loads to the engine Digital choose GENERAC POWER SYSTEMS with the confidence that these voltage regulation at+/-1%a systems will provide superior performance. • TRUE POWER ELECTRICAL TECHNOLOGY: Superior harmonics and 0 SINGLE SOURCE SERVICE RESPONSE from GeneraG's extensive dealer sine wave form produce less than 5%Total Harmonic Distortion for utility network provides parts and service know-how for the entire unit,from the quality power.This allows confident operation of sensitive electronic equipment engine to the smallest electronic component. and micro-chip based appliances,such as variable speed HVAC • TEST CRITERIA: 0 GENERAC TRANSFER SWITCHES. Long life and reliability are PROTOTYPE TESTED NEMA MG11-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility GENERACO yr i= FEATURES Generac@ Guardian® Series Standby Generator - 20 kW " •Generac(OHVI)Design Maximizes engine"breathing"for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler,reducing oil consumption resulting in longer engine life. ' µ =, •"Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life •Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. e •Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer �r engine life.Now featuring a 2 year/200 hour oil change interval �, .. •Low oil pressure shutdown system Superior shutdown protection prevents catastrophic engine damage due to low oil. •High temperature shutdown Prevents damage due to overheating. •Revolving field Allows for smaller,light weight unit that operates 25%more efficiently than a revolving armature generator •Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. •Displaced phase excitation Maximizes motor starting capability 4 -Automatic voltage regulation Regulates the output voltage to:0%prevents damaging voltage spikes ° •UL 2200 Listed For your safety Sold separately •Auto/Off/Manual switch Selects the operating mode. -Utility voltage sensing Constantly monitors utility voltage,setpoints 60%dropout,80%pick-up,of standard voltage. q-'- •Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home n' -Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 10-30 seconds ® •Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds u. M -Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute •Programmable seven day exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 12 minutes every week •Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature •Main Line Circuit Breaker Protects generator from overload '..' -Electronic governor Maintains constant 60 Hz frequency. -Aluminum weather protective enclosure Provides the ultimate protection against mother nature Hinged key locking roof panel for security Lift-out front for easy access to all routine maintenance items Electrostatically applied textured epoxy paint for added durability. •Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. -Small,compact,attractive Makes for an easy,eye appealing installation -SAE Sound attenuated enclosure ensures quiet operation. •1'Flexible Fuel Line Connector Easy Installation. -Composite Mounting Pad SPECIFICATIONS GENERAC® � 1. ,�. �;k�r`�- •Rr a w� a'�!.i�:'y-� r' s,<e_ :1Z s Rated Maximum Continuous Power Capacity(NG) 18,000 Watts Rated.Votta e X40 Rated Maximum Continuous Load Current—240 Volts 83 3 LP/75 NG _ _. _,.., K .,. .. _ Tota[Harmonic Aistortion .. ,° . .. = Less than 5� r Main Line Circuit Breaker 90 Amp Number of Rotor Poles_ 2 77 Raked AC,Fregtie __.. Power Factor 1 ^Battery Reguuomertt.(nof includectj g° __.... _ w ., Group 26R 12 Volts and 525 Cold-crarrlttng_Rmpert's Mirllmum_ .. .., __ ._ . Unit Weight(Pounds/Kilos)_ 451/2046 Sound output in dB(A)at 23 ft with generator operating at normal load 66*" Sound output in&A}.at 23'ft-with"generabi7 Quiet Test law speed exet=ciSe mode..,..,. .,. . BO's.,. �' .,:sa'°(P�"ds� `:�:°`tY sa° ,•��.. � �;`�,; ;� -.> ge�««,,,.R�°"est`'-K:, a',«°^ t r• 1 1 i "y°,�.';s....: '«�.:?„” r Ve of Engine_ _ __ ^y _. �_ 6ENERAG{)iiVt V WIN-. Number of Cylinders _ w_ _ 2- .J99cc _.. _ Cylinder Block Aluminum w/Cast Iron Sleeve Valve Arrangement " < Fd VM Ignition System _ Solid-state w/Magneto Gove€nos 5p 'T Eleetr6r1 _stem ._ _ .�-< Compression Ratio _ 9 51 _ _. Starter'. Oil Capacity Including Filter Approx 1 9 0ts/1 8L O�tu1g,P�PM;.�w.�- ..............u............. _.,�..____..__..__.. ....�...�_<.,..,..`._._.._....._._ � n•,`�< ..�._..36t1Q ._..u_...........,. Fuel Consumption Natural Gas cu ft/hr. 1/2 Load 206 Full Load 294 Liquid Propane ON(gal/hr)[Liter/hr] 1/2 Load 69(1 89)[7 15] Full Load 106(2 90)[10 981 Bequiredfaei`pressure to generator fyef trilet ai ail load ranges 5 6;7 inches&watei column for,natural gas,fQ t©,t2 inches of'wager column for LP.gas Po€Btu cDntetlt multipl •fta lir x'252Q,(t['}orits!]tr K idQtl( . ..._. p. 2-t.tne'f! lain next L ©IS r a - Sim ie User interface fOr aSe 0 © 0r8tiAn. Mode Switch -AutoAutomatic Start on Utility failure 7 day exerciser Sto s unit_..0 r is€emaved.Control Arid c er still o e7 tem° _= _a__ ._._ __ _ -Manual/iest(start) Start with starter control,unit stays on If utility fails,transfer to load takes place Programr>r bie'sFart'delaybctween t0 30 seconds _ .° _ .. ._ _ _.._. _ Standard Engine Start Sequence _ Cyclic cranking°,16 sec,on,7 rest(90 sec maximum duration). Engine seconds" . _. __ ... . Engine Cool-Down 1 minute _.SM ter eannnot re-engage until 5 sec.aftengine has slopped: Smart BatteryCharger _ Standard Automatic Vona a f? &ion with©s+e€and tlnde�Volia s ProteCHo€t _ g_.9_�..,, _�.<.__.g_ .�.._ ....< ..� _....�____... .._,�.� _,.__..a.........��•wStandard �� _.. _ ...µ....-____ Automatic Low Oil Pressure Shutdown Standard `Overspeed.Shutdown 72Hz High Temperature ShutdownStandard Safety Fused Standard Low Battery Protection Standard 50 Event Run Future Set Capable Exerciser Standard lncorrect�Wiring Protection w_ .__._w. .. _ _ ._. _..__.._.gig ._ Standard Internal Fault Protection Standard Common External Fault Capability. Standard Rating definitions-Standby Applicable for supplying emergency power for the duration of the utility power outage No overload capability is available for this rating (All ratings in accordance with BS5514, IS03046 and DIN6271) 'Maximum wattage and current are subject to and limited by such factors as fuel Btu content,ambient temperature,altitude,engine power and condition,etc Maximum power decreases about 3 5 percent for each 1,000 feet above sea level "Sound output ratings from certain points on the generator subject to change based on installation parameters. 1 �,F r • enerac° Guardian° Series Standby Generator - 20 kW AVAILABLE ACCESSORIES ,Mnde! Product _� Descripflon Every standby generator requires^a�battery to start the system. Generac offers the ,5819 °26R Wet Cell Battery recommended 26R wet cell battery for use with all air-cooled standby product. ' I If the temperature regularly falls below 32°F, install a cold weather kit to maintain 6212 Cold Weather Kit optimal battery temperature. Kit consists of battery warmer with thermostat built I ; into the wrap. 5621 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a Contact Kit single large electrical load you may not need. 5704 Paint Kit Medium Gray Kit ( ,„wmmn...x....�nmw...w ywrn,u ..m er.m"merwam,.Hamm...„,,.n.mucm.mwh.�mm".vr..mr+w+ewvam vw...mmw".rw r.men,mw®•..---•—.__•- ,am..wc,.emm.m.m»,awmm+." m. wmwa-n...w. ..mua.>. Sj( ' Generac's scheduled maintenance kits provide all the hardware necessary to 5665 Scheduled Maintenance Kit Iperform complete routine maintenance on a Generac automatic standby i IP P9enerator. —, C�n y ompletely wireless and battery powered,Generac's Nexus wireless remote monitor , 15928 1 Nexus Wireless Remote I provides you with instant status information without ever leaving the house.Not compatible with CorePower or EcoGen systems. I Advanced Nexus Wireless ! Remotely control generator functions with the advanced model's LCD display. In ° 5951 Remote ;addition to remote testing of the generator,set the excercise cycle and maintenance 1 interval reminders.Not compatible with CorePower or EcoGen systems. DLM Load Control Module DLM Modules are used in conjunction with the Nexus Smart Switch to increase {5937 (50 Amps) I its load management capabilities.It gives the Nexus Smart Switch additional load i management flexibility not found in any other transfer switch. Design and specifications subject to change without notice Dimensions shown are approwmate Contact your Generac dealer for certified drawings DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES 637 1218 125 1] [47 9] cm ev 7319 [28 81 Oil :o 642 76 2 ff3 0 J [25 3] PEA GRAV� 1226 14831 MINIMUM LEFT SIDE VIEW FRONT VIEW GENERAC• Generac Power Systems,Inc • S45 W29290 HWY.59, Waukesha,WI 53189 • generac com C=---=1 ©2012 Generac Power Systems,Inc All rights reserved All specifications are subject to change without notice Bulletin 0186190SBY-E Printed In U 3 A 10/08/12