Loading...
HomeMy WebLinkAbout41197-Z �o�gsUfFO4-ppp, Town of Southold 6/5/2017 P.O.Box 1179 0 C* 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38994 Date: 6/5/2017 THIS CERTIFIES that the building COMMERCIAL ALTERATION Location of Property: 58855 CR 48, Greenport SCTM#: 473889 Sec/Block/Lot: 44.-2-22 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/18/2016 pursuant to which Building Permit No. 41197 dated 11/29/2016 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: interior alterations to existing hotel for Building A room numbers: 100, 101, 102, 103, 104, 105, 106, 107, 108, 109, 110, 111, 112, 114, 115, 116, 122, 123, 124, 125, 126, 127, 128, 129, and 130 as applied for. The certificate is issued to SV Greenport LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 41197 5/23/2017 PLUMBERS CERTIFICATION DATED 2/16/2017 KyNneth Cordero A h ' ed Signature I TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE . . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41197 Date: 11/29/2016 Permission is hereby granted to: SV Greenport LLC CO Eagle Pt Hotel Partners LLC 270 Lafayette St Ste 502 'New York, NY 10014 To: construct interior alterations to existing motel as applied for with flood permit. At premises located at: 58855 CR 48, Greenport SCTM # 473889 Sec/Block/Lot# 44.-2-22 Pursuant to application dated 11/18/2016 and approved by the Building Inspector. To expire on 5/31/2018. Fees: COMMERCIAL ADDITION/ALTERATION $631.00 CO -COMMERCIAL $50.00 Flood Permit $100:00 Total: $781.00 in kuYidin'�" spector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses, or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of-Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. New Construction: Old or Pre-existing Building: � (check one) Location of Property: Street �� ��l�f'/lD�'✓� House No. Street Hamlet Owner or Owners of Property: --75— V 6�2 I( fir " Z—Z--(' Suffolk County Tax Map No 1000, Section Block c>Q, Lot a Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: / Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted:$ �/� OF SO(/r�®l Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 roper.richertttown.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: SV Greenport LLC Address: 58855 CR 48 City: Greenport St: New York Zip: 11944 Building Permit#: 41197 Section: 44 Block- 2 Lot: 22 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Aardvark Electric License No: 3021-ME SITE DETAILS Office Use Only Residential Indoor X Basement Service Only Commerical X Outdoor X 1st Floor X Pool New Renovation X 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 225 Ceiling Fixtures 25 HID Fixtures Service 3 ph Hot Water GFCI Recpt 25 Wall Fixtures 75 Smoke Detectors Main Panel A/C Condenser Single Recpt 25 Recessed Fixtures 25 CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Ll Switches 15] Twist Lock Exit Fixtures TVSS Other Equipment Building "A" Guest Rooms 100 through 130 (25 rooms). To Include: 14 Outside Walk Way Lights. Notes: 25 - Exhaust Fans. Inspector Signature: —<ZDate: May 23, 2017 0-Cert Electrical Compliance Form.xls Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 _ Southold,NY 11971-0959 44 v"i 41 ,� BUILDING DEPARTMENT V TOWN OF SOUTHOLD r DD I I } t Li '�' MAR - 2 2017 BUILDING DEPT. TOWi't OF SOUTHOLID CERTIFICATI.ON Date:- _ _ o� 0 L,//_77 Building Permit No._ Owner: ED- (Pleaseprini) Plumber: genn-e 41 �i3 -Je cb- " ". (Please print) I certify that the solder used in the water supply system contains Iess than 2/10 of 1% lead. (Plumbers Signature) Sworn to before me this day of 201 Notary Public, oculty CONNIE D. BUNCH Notary Public,State of New York No.01 BU6185050 Qualified in Suffolk County_ Commission Expires April 14, SOF SOUTH �o� olo H O i cOUNi`I TOWN OF SOUTHOLD BUILDING DEPT. 7654 802 INSPEC ON - [ ] FOUNDATION 1ST [ ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] -FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: b Vl� I�I UNKS 1• � '1 c Viol , to . 11 1 it4l lei? a5- DATE sDATE INSPECTOR so Z,3ccoutm, TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION FOUNDATION 1ST ROUGH PL13G. FOUNDATION 2ND INSULATION FRAMING /STRAPPING FINAL - FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION FIRE RESISTANT CONSTRUCTION FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) ELECTRICAL (FINAL) REMARKS: �,40tk L-P-4U47- DATE INSPECTOR 1�--? SOF so H 0 OUNi'1,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 '1 NSPEC p ON [ ] FOUNDATION 1ST [ ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ( ] ELECTRICAL (ROUGH) [ ] ELECTRICAL INAL) EMARKS: r v�war v✓� O L, vw� � j r DATE �� INSPECTORFN k OF SOUIy�� �ycoum, TOWN OF SOUTHOLD BUILDING DEPT. 765.1602 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLSG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY , [ ] -FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION An [ ] ELECTRICAL (ROUGH) ] ELECTRICAL (FINAL) REMARKS: DATE INSPECTO SOUlyo� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARK 4 DATE �'d INSPECTOR SO[¢yo �Courm,N�' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: Ls �S 0—LV9 ,5—; 4 '�E4,;-t�, LAMO om� lgkgz 5 7- po V-rb ®V-J�, Aw . DATE 5®I'T'6— 47 INSPECTOR ho��,oF soaryolo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: I---- _ Al 4 � o DATE �' -17 INSPECTOR Fs0 0 Ulyolo UH1`I TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] ULATION [ ] FRAMING / STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ -] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (F AL) REMARKS: CjbS ifut DdD,�51 41L S lh S 01L Q ov-V U) A u DATE . S ydl INSPECTOR • ' • • • FOUNDA TION(IST) • • �C� , . •, i `j•.4 ROUGH FRAMING& PLUMBING mffgr16i i j IW MIN Ft . . ��,��1 , ,zzl 'MMMJ -I ®r • �� • ; • � . MIA ADDITIONAL . -` �- mill � �m OWN -- �" y. 39, i 1 ',,,TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST $UILDING DEPARTMENT Do you have or need the following,before applying? ;TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX:(631)765-9502 Survey SoutholdTown.NortMrk.net PERMIT NO. Hiz- Check Septic Form M N.Y.S.D E.C. ��O y Trustees D C.O Application Flood Permit Examined 0 Single&Separate N D V 1 Storm-Water Assessment Form 2016 Contact: Approved 2& Porte: TOM Wk)12Aut§!t Disapproved a/cA;m DING**tDr�E ,� fJ �F%06 a; Phone: (pal- &91 -04014 014 Expiration 20fy J-1h ) Bu or APPLICATION FOR BUILDING PERMIT Date October 20 2016 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. SV Greenport LLC (Signature of applicant or name,if a corporation) 270 Lafayette Street,Suite 502,New York,NY 10012 (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder Owner Name of owner of premises SV Greenport LLC (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer Enk Warner,Member ,r„ (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 58855 County Road 48 Greenport House Number Street Hamlet County Tax Map No. 1000 Section 044 Block 2 Lot 22 S ' Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy HOTEL ROOM b. Intended use and occupancy HOTEL ROOM 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units N/A Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. HOTEL 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories 1 Dimensions of same structure with alterations or additions: Front NO CHANGE Rear NO CHANGE Depth NO CHANGE Height NO CHANGE Number of Stories NO CHANGE 8. Dimensions of entire new construction:Front N/A Rear N/A Depth N/A Height N/A Number of Stories N/A 9. Size of lot:Front Rear Depth 10.Date of Purchase 1/8/2016 Name of Former Owner Levin Family Limited Partnership 11.Zone or use district in which premises are situated RR Residential Resort District&R-80 Residential District 12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO 13.Will lot be re-graded?YES_NO V Will excess fill be removed from premises?YES_NO_ 6` 14.Names of Owner of premises SV Greenport LLC Address 27o Lafayette St,Suite 502 phone No.646-912-9589 Name of Architect bld architecture,dpc Address 31 W Main St,11772 Phone No 631-681-6164 Name of Contractor Mulberry Development LLC Address 49 West 27th,10th Floor Phone No. 908-727-0057 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES V NO *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO *IF YES,PROVIDE A COPY. STATE OF NEW YORK) � COUNTY OF A<l/����-)�� F f e �o�Rf�.iE� being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the @W�L p�f (Contractor,Agent,Corporate Officer,etc) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief,and that the work will be erformed in the manner set forth in the application filed therewith Sw o efore me th f,, day of 20 R 01.SCOTT,A tary Public 11T.ARY PUS ,:-Ic'C8 U j pphcan 1�tz. p` a 9, t01k , Uri Term Expir0i 8Y • APPLICATION y PAGE- 1 of 4 ~- TOWN OF SOUTHOLD FLOODPLAIN DE%rELOPMENT PERMIT APPLICATION This form is to be filled out in duplicate_ SECTION 1: GENERAL PROVISIONS (APPLICANT to read and sig_n)' 1, No work may start until a permit is issued. Z. The permit may be revoked if any false statements are made bercin_ 3. If revoked, all work must cease until permit is re-issued. 4. Development shall not be used or occupied until a Certificate of Compliance is issued. 5. The permit will expire if no work is commenced within six months of issuance. 6. Applicant is hereby informed that other permits may be required to hilill local, state and federal regulatory requirements. 7. Applicant hereby gives consent to the Local Administrator or his/her representative to make reasonable inspectioas required to verify compliance. 8. I,THE APPLICANT,CERTIFY THAT ALL STATEMENTS HEREIN AND rN ATTACHMENTS TO THIS APPLICATION ARE, TO OF MY KNOVL E�AN7D ACCURATE. (APPLICANTS SPGIi E 11/28/16 SECTION 2: PROPOSED DELOPMEN'(Tb be completed by APPLICANT,n NAME AD D R ESS TELEPHONE APPLICANT SV Greenport,LLC 270 Lafayette Street,Suite 502,NY,NY 10012 (646) 707-3609 BUILDER Mulberry Development 49 West 27th Street, 10th Floor,NY,NY 10001 908 727-0057 Contractor �' p ( ) Ar INFER bld Architecture, d c 31 West Main Street,Patchogue,NY 11772 631 681-6164 Architect P g ( ) PROJECT LOQ6TION: To avoid delay in processing the application, please provide enough information to easily identify the project location. Provide the street address, lot number or legal description (attach) and, outside urban areas, the distance to the nearest intersecting road or well-known landmark. A sketch attached to this application showing the project location would be helpful. Sound View Inn &Restaurant 58855 County Road 48, Greenport, NY 11944 County Map Tax No: 1000,Section: 0 oc : 2, ot: 20, 21,22 23 ount Ma Tax No: 1000,Section: 044,Block: 4,Lot: 5.1 FDP(93) j APPLICATIOt\ PAGE 2OFd DESCRIPTION OF WORK (Check all applicable boxes) A STRUCTURAL DEVELOPMENT ACi'fVTTI' STRUCTURE TYPE O New S(ructurc O Residential (3-4 Family) ❑ Addition O Residential (More than 4 Family) M Alteration Non-residential (Floodproofing? O Yes) ❑ Relocation O Combined Use (Residenual & Commeraal) ❑ DemoUtion 0 Manufactured (Mobile) Home (In Manu- 0 Replacement factured Home Park? ❑ Yes) ESTIMATED COST OF PROJECT S B. OTHER DEVELOPMENT ACTIVITIES. ❑ Fill ❑ Mining O Drilling ❑ Grading ❑ Excavation (Except for Structural Development Checked Above) ❑ Watercourse Alteration (Including Dredging and Channel Modifications) ❑ Drainage Improvements (Including Culvert Work) ❑ Road, Street or Bridge Construction ❑ Subdivision (New or Expansion) © Individual Water or Scr System O Other (Please Spect7y) After completing SECFION 2, APPLICANT should submit form to Local Administrator for renew. $SCTION 3 MQ PLAIN DETERMINATION (To be completed by LOCAL ADMINISTRATOR) The proposed development is located on F RM Panel No. . Dated The Proposed Development: O Is NOT located in a Special Flood Hazard Area (Notify the applicant that the application review is complete and NO FLOODPLAIN DEVELOPMENT PERMIT IS REQUIRED). O Is located iu a Special Flood Hazard Arca. FIRM zone de4gnation is 100-Year flood elevation at the site is: Ft. NGVD (MSL) O Unavailable O The proposed development is located in a floodway IBFM Pancl 'No. Dated ❑ Scc Section 4 for additional instructions. SIGNED DATE r APPLICATION tr PAGE 3 OF 4 SECTIO[ 4. ADD[TIQNAL INFORMATION REQUIRED (To he completed by LOCAL ADMINISTRATORI The applicant must submit the documents checked below before the application can be processed O A site plan showing the location of all enstuig structures, water bodies, adjacent roads, lot dimensions and proposed devclopment. O Development plans, drawn to scale, and spec ificatioru,including where applicable:details for anchoring structures,proposed elevation of lowest floor(including basement), types of water resistant materials used below the first floor,details of floodproofmg of utilities located below the,fust floor and details of enclosures below the first floor. Also Q Subdivision or other development plans (If the subdivision or other development exceeds 50 lots or 5 acres, whichever is the lesser, the applicant must provide 100-year flood elevations if they are not otherwise available). ❑ Plans showing the extent of watercourse relocation and/or landform alterations. ❑ Top of new fill elevation Ft. NGVD (MSL). ❑ Floodproofing protection level (non-residential only) FC NGVD (MSL). For T. floWliroofed structures, applicant must attach certification from registered engineer or architect. ❑ Certification n from a registered engineer that the proposed activity in a regulatory floodway will no( result in any increase in the height of the 100-year flood. A copy of all data and calculations supporting<this finding must also be submitted. ❑ Other: SECTION5: PERMIT DETERMINATION M be completed L AL ADM1Ni RAT R I have determined that the proposed activity.A.0 Is B.❑ Is not . in conformance with provisions of Local Law # . 19 The permit is,issued subject to the conditions attached to and made part of this permit. SIGNED , DATE If BOX A is checked, the Local Administrator may issue a Developmen( Permit upon payment of designated fee. If BOX B h checked, the Local Administrator will provide a written summary of deficiencies. Applicant may revise and resubmit an application to the Local Administrator or may request a hearing from the Board of Appeals APPLICATION a PAGF_ 4OF4 APPEALS Appealed to Board of Appeals') ❑ Yes O No Hcarmg date: Appeals Board Decision --- ApprovcdI ❑ Yes ❑ No Coaditroris SECTION G AS-BUILT ELEVATIONS (To be submrtled by APPLICANT before Ccrtrftcatc of Comphancc is issued The following information must be provided for project structures. This section must be completed by a registered professional cugkncdr or a Licensed land surveyor (or attach a certification to this application) Complete l or 2 below. 1_ Actual (As-Built) Elevation of the top of the lowest floor, including basement(in Coastal High Hazard Areas, bottom of lowest structural member of the lowest floor, excluding piling and columns) is: Fr. NGVD (MSL). 2. Actual (As-Buil() Elevation of floodproofng protection is FT. NGVD (MSL)_ NOTE: Any work performed prior to submittal of the above information is at the risk of the Applicant. .4; SECTION 7• COMPLIANCE ACTION (To be completed by LOCAL ADMINISTRATOR) The LOCAL ADMINISTRATOR will complete this section as applicable based on inspection of the project to ensure compliance with the community's local law for flood damage prevention. INSPtCIIONS: DATE BY DEFICIENCIES? ❑ YES ❑ NO DATE BY DEFICIENCIES? ❑ YES ❑ NO DATE BY DEFICIENCIES? ❑ YES ❑ NO SECTION 8 CERTIFIQATE OF COMPLIANCE(To be completed by LOCAL ADMINISTRATOR) Certificate of Compliance issued: DA'I`S: BY , a Attachment B SAMPLE CERTIFICATE OF COMPLIANCE for Development in a Special Flood Hazard Area • TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE FOR DEVELOPMENT IN A SPECL4L FLOOD HAZARD AREA (O"'NER MUST RETAIN THIS CERTIFICATE) PREMISES LOCATED AT: PERMIT NO. PERMIT DATE OWNERS NAME AND ADDRESS: CHECK ONE: ❑ NEW BUILDING ❑ EXISTING BUILDING O VACAN7 LAND THE LOCAL ADMINISTRATOR IS TO COMPLETE A. OR B. BELOW: A. COMPLIANCE IS HE, CERTIFIED WITH THE REQUIREMENTS OF LOCAL LAW # , 19 SIGNED: Y DATED: B. COMPLIANCE IS HEREBY CERTIFIED WITH THE REQUIREMENTS OF LOCAL LAW # , 19_, AS MODIFIED BY VARIANCE # , DATED SIGNED: DATED: CIC(93) Scott A. Russells°s"` k �['{0)IIb I��l[1A\�f IElfb. SUPERVISOR MANAGEMENT G EMUENT SOITIHOLU TOWN HALL-P.O.Box 1179 p �0 53095 Main Hand-SOtTTHOLD,NLWYORK 11971 �yol r1- Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET (TO BE COMPLETED BY THE APPLICANT) DOES THIS—"PROJECT INVOLVE—ANY OF—TRE FOLLOWING? Yes No (01M ALL THAT AMY) ❑�A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑�. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. [:1 WE Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑[j D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑�. Site preparation within the one-hundred-year floodplain as depicted on FIRM Map of any watercourse. Q[ Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all or the questions above,STOP! Complete the Applicant section below wilb your Name, Signature,Contact Inrormntloo,Dale$ County Tax Mop Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above,please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT•iPropeny Owner.Dnign Professltirul,Aeent.ComS.CT.M. •: 1000 Dai iaetor,Other) uwlkl NAMEIe.L K rt►e,Lr�r¢... erg .2.Z // to ^ Section BIocR IT, I.OR BUILDIA;DEP Vt'r-%•IEN'r L--l.0\L1' Comas wcntwt.it CG kiv� 70 7--3 60 9 Reviewed By: Date 1/—��— _ Property Address/Local ton or co0meucou Work. Approved for proceao-ing Building Permit ti Stormwaier Management Control Plan Not liegwrcd Stormwater Nlanagcmcat C milml Plant Required Werward to Engmeermr Deparinuni for Review) CORM • SMCP TOS MAY 2011 tio��pf S��ry�! o Town Hall Annex Jxf Telephone(631)765-1802 54375 Main Road y {631)76595 P.O.Box 1179 Pet Q roger.richertCa'O`wn.s0lltliOltl.ny us Southold,NY 11971-0959 Al BUILDING DEPARTMENT TOWN OF SOUTHOLD i APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: Company Name: OAT Name: License No.: 3 I m 6 Address: g N e l Phone No.: 5 JOBSITE INFORMATION: (*Indicates required information) *Name; N G&MAWUC 3 *Address: COLkk j *Cross Street: *Phone No.: Permit No.. ti 1 )KI- Tax-Map District: 1000 Section: Block' Lot: i *BRIEF DESCRIPTION OF WORK(Please Print Clearly) IWALLIN614-IA E�Nt:1 � f (Please Circle All That Apply) *Is job ready for inspection: YES NQ ( RO�Ughln Final *Do you need a Temp Certificate: YES NO Temp Information (if needed) *Service Size: 1 Phase 3Phase 100 150 200 300 360 . 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead s Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form �- o� CNV Sc m 6QQ-L� t� —2—22 TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER ' STREET g VILLAGE DIST. SUB. LOT Cyr ego �D r ACR. REMARKS TYPE OF BLD. PROP. CLASS 41S S P# 17 ec � rw.'r— 21330 LAND IMP. TOTAL DATE � al o/coz//&- i3FW-01?P- 6 ' A A 4 FRONTAGE ON WATER HOUSE/LOT BULKHEAD TOTAL 91�_7+l RD TOWN OF 50 DIST. SUB. LOT OWNER STREET��� � VILLAGE I. v` Rom 1►I.' � Cl Rad+' 1"lY r�[,l r lJ�. 1--1 ACR. F,�QRMER OWNER N�. �.�--�. d -�} ..�� r- c,_7j (k �� �"�' f'�s TYPE OF BUILDING 100 vin RES. SEAS. VL. FARM COMM: CB. �< Mkt. Value LAND IMP, TOTAL DATE REMARKS �' 9 'v 6,o - _ J - S-00 PAr 30, 000 ,�,g O,/- iey;�T Or 0 . t?=160 +,rSOO 0 1 ©0 / Z7 Ik 3c� � frx ti � Tr 3S e Z J / ►ro �_ A, 9.3 Bpql 13 0 -cam 3o r -� P�✓1.Yd :�`Q r/r /v Meadowland _ : - : ..:•, AGE BUILDING CONDITION NEW NORMAL BELOW ABOVE 3 r�� �eocie�rJ �,+� FARM Acre Value Per Value q/7-3/Dq �Z,JJ/ 2-1—Le V(4 V f5 77J k0-, 'n t+ `.� ;,rK Acre r Tillable FRONTAGE ON WATER v ? _ a ti C Woodland FRONTAGE ON ROAD DEPTH / U �1A j BULKHEAD �f { House Plot - ,�.�, :✓ DOCK 1 Z -7 1Q - j Y ®( ,� �';{} '1'I ?Z3 la Zoo� Totd ` � � z0051 0q1 - 5a-660 Q) 09/- f D- y 1350/ Z010/f( - 41 350 COLOR Y TRIM C�(/ _ �1 1 G ~ g7- 4 .,`+y«G. -� f...ww- .:7 .....� .�rfBV�a. a sa�u(�e,�,..--.g'i^'t' _ .. ...«. mow,.. ':..-5°»:wa%w;;n,,'"` m`:_`." "�. n•;;,.,,my3""x , _ DOW M. Bldg. Extension Extension Extension G Q Foundation po Y Bath r' Dinette -' �S �D _ i3.Ga-• Coin cy� �. Porch . B ement � tl� Floors j K. .Porch, Ext. Walls Interior Finish LR. _ razeYV4�j Fire Place ,} Heat DR. e_ Type Roof Rooms 1st Floor BR. gtio ''','a,., Recreation Room Rooms 2nd Floor FIN. B 0. B. ;.J Dormer Driveway " Total 010 05 ( d'75x 10 024 1-/3,72-)TOWN' ~ .; ILLAGE` DIST: _ SUB. LOT _ . _STREET__.__. _ _ �ir�US (9,!' x l0 0fl•392 __ - - 16 TOWN OF SOUTHOLD= P�tOPE�TR��`7�D=-CTARD� OWNER STREET ".1, VILLAGE H= DIST. SUB. LOT „ VORMER OWNER N pp ACR. ° Wr* ' I ? S r TYPE OF BUILDING _RES. SEAS. VL. FARM COMM.VCB. to4S,E; Mkt. Value LAND IMP. TOTAL DATE REMARKS \� o d 0 1-4 t d® J �I AK ,.�l�e� �_�f `�aiUg t�� f� � •��� / / 0 � � �a �A ire .�:� :�3'• O k, s Od .Cy+IN 6 (e�tt e r ;j ;' ? �m ✓#3!. �`-j'� . . fi-- ...� B ••• l ,�'rte, �f`} � � ,}'j/J . .. p_ � - (' ?0 {o o �'i`1 I 7 \ J7- -� a •WLI'iLfVti'�rf_ACa eoa•."• /.�1 r. O� L 0 Ir / 6 (, (/ NEW NORMAL- BELOW ABOVE FARM Acre Value Per Value Acre � �• - � ' Tillable. 1 Tillable 2 Tillable 3 Woodland Swampland FRONTAGE,ON WATER FRONTAGE ON ROAD } } i-,Brushland JrY k House Plot DEPTH r " ,v r BULKHEAD !Total" DOCK a i } ', NOON■■ ■■■■■■••�■■■■■■■■■■■ Y •• C.......N■■®............■■■. ■■■■■..■■■■■■■■■■■N■ MEN■M . .......■ MEN N z r, .. ■ NOON ■■■■■■NONE■■■■■■■■■■ X - , ti _".r r .._ ■©_NNNN ■■NENNNONE EN■NEN_■ENO Mal - �■NNN■N N■WIN NEI MEN Emig No 01 �ommosimmmoom EMMEN MENEM mom �tieo-rt mom ME : .. ound. Basement Ext. Walls Interior Finish Fire Place • oil Rooms 2nd Floo Driveway �1 i ,-oral I_ I � I� •���.I�� - I � � � _ ....8.v—•a+ .a.a le�'b'>a —P^.,�E._'l'.P'a.,j 4"w 4 �.. .S y v r a..tw«.w...._.. � •� � ±� P offh�%�nw .1* .,��, _r ��„; N �, � �a..m...Y�.e."S .v. ara.._Y .r.�+... ♦.:'.��c-l.°. .:1 TOW LU OWNER STREET VILLAGE DIST. SUB. LOT F ff RMER OWNER N E ACR. S W TYPE OF BUILDING RES. SEAS. VL. FARM COMM. CB. MISC. Mkt. Value LAND IMP. TOTAL DATE REMARKS R AGE BUILDING CONDITION NEW NORMAL BELOW ABOVE FARM Acre Value Per Value Acre Tillable 1 Tillable 2 Tillable 3 Woodland Swampland FRONTAGE ON WATER Brushland FRONTAGE ON ROAD House Plot DEPTH BULKHEAD Tota'-'- DOCK - 4 wwwwww ■�■■■■■ wwwwww■■■■■ wwwwww® ■■w■■■■■■■■■■■■■■■■ ■■■■■ ■■■w■■■■■■■■w■■mom ■ _ _ - ■■� ® ■■ww�w�ww■■■■w■■■■■ Elmo 41100 www ■ ■ �■■■■r■rKl■w■■■w■■w . .. _ .= www■ ■ �■■■■■ l■■■■■■■■ ■w■■i■■■ ww■■■rww■■wKiwwww■■® ■t■w■w■�i■■■mom www■NINE No w■■www W� Yr. ` Y'.f^"t T+":`rytiW!j.^" Wt" '3n' S�.1`.Iwm. +y�;•""' "n, , 1 w. _ , n. �.� � ��. -�� ww��r�ww�■ �R�■www■ w S> 1r-.LL.: J'ti' +YKr+:'2 ''ih w•e•^ir'} rh ~ - ww■ww� ■■wwwwwww■eww■■■www■■■www■■ ..• wwwwwww ■■w■■■■■■■■■■■■■■■■ wwwwww www■■ww■Interior wwwww MIN • nish • Rooms 1st Floor Rooms 2nd Flo rMer Driveway • • _ •• i _ ,'L, vi, s•.Ty'a CVs ;,b}. 'm .- :_ .. t ... ..aJ'. .. .a• ,- - - - , .,..' -v,.'r� �=�.-`-:-'. _ -_ s'a�,�x+^.. `" ,."s .n. ,.. �^qt�`.e� - •` i`,sd�;._... tr - 4.:�- - '�, -. D si' ON -SCITHOLOTPk, x ERr •4 Z ' F - RECO ® BARD OWNER STREET VILLAGE DIST. SUB. LOT FORMER OWNER N E ACR. ` S W TYPE OF BUILDING J RES. SEAS. VL. FARM COMM. CB. MICS. Mkt. Value i LAND IMP. TOTAL DATE REMARKS D 60 3 0 d0 60 B — GQ AGE BUILDING CONDITION NEW NORMAL BELOW ABOVE FARM Acre Value Per Value Acre Tillable FRONTAGE ON WATER Woodland I FRONTAGE ON ROAD Meadowland DEPTH House Plot BULKHEAD Total DOCK COLOR TRIM K Extension ._ - r JExteris on - s ' ` Foundation Bath Dinette Porch;''' Basement Floors K. Porch- Ext. Wafls Interior Finish LR. 'Breezeway Fire Place Heat D.R. Garage. Type Roof- t Rooms 1st Floor BR. Patio., Recreation Room Room's 21d Floor FIN. B iO. B. - Dormer Driveway E i LO:CATIONyMAP. ` P.,kerRook - SITE L❑CATI❑N D A,- PDQ a • -1✓ �0 1/ AYshamom e He-a-OM..k?Bach MSP° AteERrsotiw o-�' ° '/lrsbamamaRua SURVEY OF PROPERTY DouNonEM aYE HOsh°n.omucn �^ AT ARSHAMOMOQUE TOWN OF SO UTHOLD TAX IAT 29 q ='�r� S 9���" Pona SUFFOLK COUNTY, N.Y o a yg v Wa 1000-44-02-20, 21, 22&23 1000-44-04-51 SOTTND SCALE 1"=40• �7 AT.iD 1..1 V o p9� � FPEEKea a �0 1-'r- SEPTEWBER 21,20/5 Lts1N b Eo 0 OCTOBER 6,20/5(REYTSTONS) G 1 DECEMBER r 2015(RENSIONS) *O1N DECEMBER I7,2015 (REONS DECEMBER 2015 ( IAMS) COUNTYOT� COU OFIX JANUARYS,2016(REVISIONS) LOT TAX OT L , �r•�N INN i ��,A Im -Lois %T .p a Sb°N;y fiat p°a v TIt1CT TAX LOT 18 va TAX LOT 20 AX LOT 22 yONO D Sq/NONEW yet Yo1EL I s �n .a d ' NL'SIAURAN ' .. 001,• .•SOL, 2 •,a.� i� /�` �•; -... 1mARm emtawc � vAp¢e e ",.. araNa.� oa,,,,,•AW.•on -, roF.,..- n WE snnrmAue YD OMLw RAv jYYN rtLIM)s ,. �� 1,l.'• � 1 . noaW.�' AA.•`.a„ �. e e — , ayo• f� — — ����e�=v'�.:,:• � �— �»o,oR�, — _ Rin — NORTH RO • -•� (CR 1 -�rr�L •� MRR ROAD / (aR .. - u , PMC+ CWRT REMEA Rw AREA •• ,// I a MEL e+ &L s FEET a + I •sL�Pnesrsrzl�a• Ig LONE$ KEY " °m • I 1. ' \ 1000- 1070 DTgiCT Re0 MMM -9EILND5 + ! e0w yOOG — o NETLANDS FUG + , r sewn \ + • „o1TB STEEL COVER-CP-ST-DW + I • I 0 - -UTILITY PIX£ ++ I I•' / U 8I• p -HIDRANT -HANDICAPPED ACCESSIBLE PARIONCIT \. 6 a WASTE UNE + 1 ya�rrY.Y + l9M✓ � S e OVERNEAD MIRES 1 + ++ CAS UNE •' REV DATE CK DESCRII'TION COASTAL EROSION[WE +I ^ s r�•Y,"'� •1•-++"":NOS+ WOOOw FENCE . "\ .CNANNUNK FENCE CER17RO Ii F \+ + ro Sv CRfENPORT,LLc REVISIONS i -WATER PAIN + , _ SNfY CREEK OREFNPORT LLG,WD/TS SUCCESSORS AND ASSIGNS - EDGE CLEA fIECTAIC LINES RANDS`+ + + LFM-COASTAL ER09aY HAZARD AREA YAP PHOTO 53-591-83 FIRST AMERICAN n7LE INSURANCE COMPANY Sound View Inn -mQ OF LYEARWC + ++' . + + TMS TO CM77FY THAT THIS MAP OR PLAT AND THE SURVEY ON%MCH IT IS Y BASED MERE MADE IN ACCORDANCE MIN THE 58855 North Road FRESHWATER METUNO BOUNDARIES + + AREA BY TAX LOT SURVEY,011 /MUld JOINTLY ESDARD DETAIL TABLISHED AND /REYwTS FOR ALTA/AC91 LAND nf!£ Greenport,New York 11944 AS OQINEA7ED SGwC£RESEARCH ASSOGA7E$ Y ADOPTED BY ALTA AND NSPS.AND INCLUDES IIEYS 7,3,4,6,7().7(6)(/),89,10,11 8Y/N7ER-SawCE RESEARf3l ASSOGA lE$-WG W AUGUST 7B,10/5 •• 1 + f ElEYA—ZONES—FRO—MR—RM EWS AND CLIYTWR TINES ARE RErtRwcm m NAtD + AND IJ OF TABLE A MOD-4+02-20:��10�L ,HEREOF,HE FIELD WORK WAS CO/PLEIED ON SEPTEMBER 21'7015 J.R.HOLZMACHER P.E.,LLC p fL0U0 ZONES FROM FlRM J6IOJCOIS7N + •J 21 00672 AC3®b 7E llE / - NYS UG NO 496/B .. f 22-tET72 ACJEB to 1E LTE DATE OF PUT G7 YAF DECEAIB£R 29.ZOIS PECONIC SURVEYORS PC ANY ALTERATION OR ADDITION m iN/S SLRVEI'/S A"MDOZY 23•1710 AC ES b I E LTE a'-EPT AS nog C nfE N6W YLRK STATE FDUGRON uw MOD-µ#1T.10=A�1p�LDE (631)765-5020 FAX(631)765-1797 EXCEPT AS PER SECRON 7209-SUBONSIaY 2 ALL CERTNCADLWS P Q BOX 911 The Third Generation of—Excellence H£ITEON ARf YAUO FIM 77R5 YAP AND COPfES]HEREOF ONLY/F A�A.�4->Zg TOTAL ACFi£8 1230 TRAVELER STREET 1 f In Water Supply,SA/O YAP OR UREA BEAR THE OPRESSED SEAL F THE SURVEYOR 12JO LD,N Y 1197/ 15-199 t PPM.Rater Resources, MHOg sGyATURE APPEARS HEREnv Civil and Environmental Resources, SURVEY 3555 Veterans Memorial Highway, Suite A,Ronkonkoma,NY11779 SCALE= 170 PHONE(631)234-2220 FAXE-MAILf Qa(631)234-2221 E-MAhol-d-rom 1 SURVEY 3 I—ay Hui s'$' Mamh 10,2016 C-1 n��K°°cv,®vrax�rarw nwH9�rDY FM Ea -16-01 L' .rCAT10N MAP.. 4`,,a OR 1 - ParkerRoGF / Da ' SITE L❑CATI❑N D r Arsllamonagae v .'�y0-c �r� =/'/,H,e ham m'uGF'B ach `DNY a° ALaERnoN rN ,,, s4zOT9a,..,9 SURVEY OF PROPERTY AT ARSHAMOMOQUE 1.,. AVE 990 NvshOmn�D'D` 'hF 9L can, TAX TAT 2saeo TOWN OF SOUTHOLD - SUFFOLK COUNTY, NY 1000-44-02-20, 21, 22&23 � "/' �" 4'0 ,• �- �p 1" �_ � 1000-44-04-51 S'Q VND m .ori .� -� S OCTOBER 6 SCALE 1" 40' , SEP7EMB2ERM5(21,REVIS2015IONS) G LAND _m ,+�� qa a=01DNRD Da cPI EE^DR 4 i D , DECEMBER 1,2015(REVISIONS) N / DECEMBER 1Q 7,2015(REVISIONS) /� �r•r�yINN „A / Im w, DECEMBER 5( S) COUNTY OSUFLK COUNTY SUFFOLK ZONE JANUARY 5,2016TAX T 1B / TAX LO(REVISIOT SET J-/ �''• ` sa'NDY�"°.+��»°a : - TAX LOT IB TAX TAT 20 AX LOT 22 ZONWOI pISTgIOT RR ✓/ 0 TJ ayno�-•�+ / 1 LDV) rf'.; ! \ - .. r. � � alCzv-O IOUs' f✓ .r�ONEW INN F14 Y0 .. .-� • x m $WNOHEW NN " �=—==L- Nr II1sT(W f fRAM[O BI/IIDe _ o ( y �'� , '�' Rav1'�M LL.N Rxy av�.y�qn s,/o w�-sYa.t,ay QVE SIOPY£AAYE YD v NEW RRI rY�gIDGJ�1� � . +�J'�� •�f.Frl�•• � •-,• I y •�•�'••ns•tlwwr � A dd � 1 �W' (f, -- ---- T_��1- � ®�—, —xo�iw w �iE,w _ __ °�� LI - y -rmEar. NORM ROv- _•m (GR ) •dw— e• ' -mom_ NORM /'" :�AVID �• i (aR t.—Z ���y r i �$ ZONE X �.-� � ✓'_ _ �,/ @+3,��- IL FSEG' IR€ t 1 (V COURT REMEAROV AREA / /• •'{IR� ZONEFE a IEL By y I / \ , to Z JEFEET 1 / a I '"E"P7rc ss°mmis �• ZONE X KEY yFREZW�5�x i I Io t000* °QCT R90 YyY =WE7LAN0.S y ZONING DIST s x o WETLINDS FLAG SIM COVER-CF-ST-OW I I x = ~ UTILITY POLE 1,/ -I' / •fir / �Iw�� / x x q =HYDRANT =NANO/CAPPED A-- WASTE —PARKINGWASTE UNE y I �vaz,r+..'' y •oM�'�x� e OVERHEAD WRES GAS x REV DATE CK DESCRIPTION COASTTINGAL EROSION UNE y 1 ^ Tti • x x1U,NOS x y HAINU FENCE y CERTIFIED TU- REVISIONS MODE NK FENCE CER •x\r x y y % / TO SV GR£ENPORT,LLC e =WATER MAINROU x y .,"� SNEY LRERI CREENPOIN INSURANCE /Is SUCCESSORS AND ASSIGNS SOUIld View IIlII UNDERGROUND ELECIR/C LINES N£BANOS x CEHL-COASTAL ER090N HAZARD AREA NAP PHOTO 53-591-eS FIRST AMERICAN nRE INSURANCE CaVPNY g� =IDLE CLEARING y y V y TMs TO cm TRY MAT THIS MAP OR PLAT AND THE SURVEY ON WHICH IT IS A x x Y x BASED WERE MADE IN ACCORDANCE WITH ME 58855 North Road FRESHWATER WETLAND EORM R/ES 2011 MINIMUM STANDARD DETAIL REG TS FOR ALTA/ACSU LAND DTIE Greenport,New York 11944 AS DELINEATED C-E RE.E RESEARCH GAIFSl T AREA BY TAX LOT SURVEY,JOINTLY ESTABLISHED AND BY INTER-SGFNCE RESEARCH ASSOCIATE$INC!NG ON AUWST 1Q 2075 y ADOPTED BY ALTA AND NSPS AND INCLUDES ITEMS 2,J,1,8,7(a),7(6)(1),89,70,11 QEVARONS AND CONTOUR LINES ARE REFERENCED 10 NAVD y • AND iJ OF TABLE A CODMOYFE 21 DzenAL7EBbTELRE THEREOF THE FIELD WORK WAS COMPLETED ON 'SEPTEygER 21.2015 J.R.HOLZMACHER P.E.,LLC FLOOD ZONES FROM FIRM J6IOJWI57H y ZI-apy72 ACAEB b TE LRE N Y5.UG NO 49878 -17'm A� uE OA7F LY'PLAT OrP YAP DECEAlBER 29.2015 ANY ALTERADON OR ADDITION m MIS SURVEY 6 A MOLT ROV 9-17177 AL3E8 EOTE L!E PECONIC SL 0'10 FAX(6JI)765-1797 OF SECRON 7209 OF ME NEW YORK STATE EDUCAnON UW EXCEPT AS PER SECDON 7209-SVBDISIA"Z ALL CERRHCARONS r MOP44-04-51-103M ACAEB b 7E LPE I HEREON AflE VAUD FOR MIS MAP ND COP!£S THEREOF ONLY IF P a BOX 909 The Third Generation of Excellence SAID NAP OR CCWIEs BEAR ME IMPRESSED SEAL[K ME 9/RYEYOR AREA-14,128 TOTAL ACRES WHOSE SIGNATURE APPEARS HERECN 12JO TRAVELER STREET T SOUTHOLD,NY 11971 15-199 ) In Water Supply,Water Resources, g Civil and Environmental Engineering SURVEY 3555 Veterans Memorial Highway,SuueA,Ronkonkoma,NY11779 SCALE= 170 PHONE(631)234-2220 FAX(631)234-2221 E-MAIL j @hol—hn rom b SURVEY 9f Z DesIDN®gr ITVS sDA� 130 JRH re M=h 10,2016 C-1 A1.7m�n M x- FM ex0lEaxo- EagPT-16-01 s Soundview Inn Fire System# 176-9791 IN THE EVENT OF A FIRE DIAL 911 AND EVACUATE EVERYONE FROM BUILDING FOR SERVICE CALL SUFFOLK SECURITY SYSTEMS (631) 765-5262 CENTRAL STATION (800) 434-4000 SIGNAL# 1769791 Zone# Location Description Zone# Location Description 1 ROOM 100 26 ROOM 130 2 ROOM 101 76 W ELECTRIC BSMNT HEAT DETECTOR 3 ROOM 102 77 EAST PULL STATION 4 ROOM 103 78 BASEMENT EAST,PULL STATION 5 ROOM 104 79 SPRINKLER WATER FLOW 6 ROOM 105 80 FITNESS ROOM 7 ROOM 106 81 GATHERING ROOM 2 8 ROOM 107 82 GATHERING ROOM 1 9 ROOM 108 83 OFFICE 1 10 ROOM 109 84 OFFICE 2 11 ROOM 110 85 W HEAT DETECTOR 12 ROOM 111 86 HEAT DETECTOR 14 ROOM 112 87 LOBBY BASEMENT 15 ROOM 114 88 LOBBY BASEMENT HEAT 16 ROOM 115 89 BASEMENT HEAT 17 ROOM 116 90 BASEMENT SMOKE 18 ROOM 122 91 BASEMENT SMOKE 19 ROOM 123 92 BASEMENT SMOKE 20 ROOM 124 93 BASEMENT SMOKE 21 ROOM 125 94 BASEMENT SMOKE 22 ROOM 126 95 BASEMENT SMOKE 23 ROOM 127 96 HEAT DETECTOR EOL 24 ROOM 128 97 WEST PULL STATION 25 ROOM 129 98 WEST CENTER PULL STATION 99 EAST MIDDLE PULL STATION May 26, 2017 Honeywell IPGSM-4G Single or Dual Path Commercial Fire Communicator General =� The IPGSM-4G is a commercial fire alarm communicator that offers contact ID reporting with any Fire Alarm Control Panel �•' (FACP)that has a built-in dialer.This single or dual path com- municator connects directly to the primary and secondary communication ports of a fire panel's Digital Alarm Communi- cator Transmitter (DACT). It offers three selectable reporting paths which include: Cellular only, IP only,or IP primary/cellu- lar backup. All signals from the IPGSM-4G are delivered to Honeywell's AlarmNet Network Control Center, which routes highly encrypted Ethernet data packets via a customer pro- vided internet connection or cellular network to the appropriate central station.The state of the art AlarmNet network control center is fully redundant and monitored 24/7. AlarmNet has . Multi-GSM platform compatibility for 2G, 3G and 4G net- the ability to route messages using AlarmNet-I and 800 PLUS works. services, providing true redundancy and multipath message • delivery. Operates over the following communication protocols: HSPA+ (4G) HSPA (HSDPA & HSUPA) (3G) EDGE (2G) Alternative communication methods are critical in the market- GPRS(2G). place due to VolP(Voice over IP),migration from POTS (Plain . Selectable reporting paths and supervision intervals to Old Telephone Service) and growth of digital radio networks. meet NFPA 72, chapter 26 requirements. (Compliant with The IPGSM-4G's single path communications solution allows NFPA 72 2010 and 2013 supervision requirements.) one technology to be used(either IP or cellular)to provide the appropriate connectivity to a central station.For added reliabil- . Works over any type of customer provided Ethernet 10/100 ity, our exclusive dual path solution allows both technologies based network connection (LAN or WAN), DSL modem or (IP and cellular)to be used together for maximum,survivability cable modem. or for local jurisdiction requirements that specify a dual tech- • Data transmits over standard contact-ID protocol but is nology system, secured with the industry's advanced encryption standard The IPGSM-4G is designed to operate over the most common (AES 256 bit). cellular networks including 2G,3G and 4G.Its multi-GSM plat- • Supports both dynamic(DHCP)or Public and Private Static form technology automatically chooses the best available cel- IP addressing. lular-signal in the area based on signal strength and • Built-In Power Supply module: On board charging circuit seamlessly self-adjusts to maintain critical life safety communi- design accommodates back-up battery. Includes primary cation. In addition, it connects to any type of customer pro- power and battery supervision. vided Ethernet 10/100 base network connection (LAN or . Diagnostic LEDs:Signal strength and status indicators. WAN), DSL model or cable modem. Our selectable reporting Reliable connection: IP and GSM connection tested every path feature allows the radio to be configured for a single or dual path solution as well as the appropriate supervision inter- vals based on NFPA 72 requirements. (See diagram below for • QOS: Quality of Service diagnostics via AlarmNet conveys selectable paths and supervision timing intervals.) vital communicator information including when message was received,signal strength,and message path used. • 7720P Hand-held programmer for easy setup. Selectable Path Description Supervision Times Operation 2010 GSM Single Path(cellular only) 5 minutes When an event occurs,the Fire Alarm Control Panel goes off 2010 IP Single Path(IP only) 5 minutes hook to dial the central station.The IPGSM-4G Dialer Capture Module detects the off-hook condition and provides the fire 2010 IP&GSM Dual Path(IP and cellular) 24 hours panel with a dial tone. When the fire panel detects the dial 2013 GSM Single Path(cellular only) 1 hour tone, it begins dialing the central station. After the dialing is completed,the Dialer Capture Module returns a handshake to 2013 IP Single Path(IP only) 1 hour the fire panel.The fire panel then sends the contact ID reports 2013 IP&GSM Dual Path(IP and cellular) 6 hours to the Dialer Capture Module, which in turn sends a kiss-off after the report is successfully received from the fire panel. The Dialer Capture Module sends the contact ID reports to the Features IPGSM communications module. When all the reports are • Saves the cost of two dedicated phone lines. sent, the fire panel goes on-hook. The IPGSM communica- • Single or dual path communications. (Can communicate to tions module then transmits the messages to the central sta- central station using cellular technology,internet or both. tion either over the GSM network or the Internet (dependent • Requires no change to the existing Fire Alarm Control on configuration). Panel configuration. (Connects directly to the primary and secondary telephone ports of a DACT.) Easy to Program -One 12 V 7.0 AH lead-acid battery(not supplied). The IPGSM-4G communicator can be pre-programmed using —Battery charging current: 1 Amp maximum. the 7720P programmer to enter all central-station Information. —Battery discharge current. Standby 230mA, Active This is saved to the IPGSM-4G communicator panel memory. 950mA. When the IPGSM-4G communicator is installed at the site and connected to the Internettintranet, it registers itself with the Cabinet Specifications AlarmNet receiver. Dimensions: 14.875"H x 12.75"W x 3.0"D(37.8 cm H x 32.4 .For most installations,the only required parameters are cm W x 7.6 cm D). • Primary City ID (two digits) obtained from your monitoring Color:Red. station. • Primary Central Station ID (two digits) obtained from your Shipping Specifications monitoring station. Weight:5.3 lbs.(6.94 kg). • Primary Subscriber ID(four digits)obtained from your mon- Dimensions: 15.625" H x 13.79" W x 9.25" D (39.7 cm H x itoring station. 34.9 cm W x 23.9 cm D) • Communication Module's MAC ID, and MAC CRC number located on outside of box,and inside of the module. Temperature and Humidity Ranges All of these parameters are assigned by the monitoring station. This system meets NFPA requirements for operation at 0 - NOTE: Some assembly is required. See Installation and Setup 49°C/32-120°F and at a relative humidity 93%±2%RH(non Guide#800-12454 for full details. condensing at 32°C ±2°C (90°F±3°F). However, the useful life of the system's standby batteries and the electronic com- Fire Communicator Capability ponents may be adversely affected by extreme temperature The IPGSM-4G is compatible with fire panels that use the ranges and humidity. Therefore, it is recommended that this Contact ID communications format as described in the SIA system and its peripherals be installed in an environment with DC-05 standard. a normal room temperature of 15-27°C/60-80°F. AlarmNet Product Line Information Honeywell's AlarmNet has been the nationwide leader in IPGSM-4G: Internet and Digital Cellular Fire Alarm Communi- alarm communications technology since 1986.A reliable alter- cator Panel. Includes red cabinet with Ademco key and lock, native for the transmission of alarm signals,our radio network wall outlet box,Dialer Capture Module,IGSM Communications provides extensive coverage in the United States and Canada. Module, antenna & mounting adapter, PowerBoosti power AlarmNet Network Control center processes signals from pow- supply, LED display board, transformer, manual, & required erful servers in multiple locations equipped with 24/7 infra- screws,cables,etc. structure support.The AlarmNet network consist of redundant Antenna Kits hardware servers,hot back-up databases and generators with GSM-ANT3DB25KT:25 ft.antenna kit.Includes GSM-ANT3DB, battery back-up at all locations to ensure continuity of service. WA7626-CA adapter cable,and a 25'RF cable. Signals from Alarm-Net are transmitted to the central station's GSM-ANT3DB50KT:50 ft.antenna kit.Includes GSM-ANT3DB, receivers using multiple communications paths consisting of WA7626-CA adapter cable,and a 50'RF cable. the Internet,radio network or toll-free POTS service. Antenna External Hardware Installation Requirements GSM-ANT3DB:3db gain external/remote antenna. WA7626-CA:SNA to N Adapter. UL COMPLIANCE 7626-SOHC:50 ft.antenna cable,low loss. To meet UL864/NFPA,ensure the following: 7626-25HC:25 ft.antenna cable,low loss. • IPGSM-4G must be installed in accordance with NFPA NOTE- The GSM-ANT3DB and the WA7626-CA are both required (National Fire Protection Association)standards 70 and 72. for installing an external antenna along with the necessary cable • IPGSM-4G must be mounted in the same room and within needed(7626-50HC:50 ft.or 7626-25HC:25 ft.) 20 feet of the fire panel. Other Accessories • IPGSM-4G, and all equipment used for the IP connection 7720P: IPGSM-4G hand held programmer. (such as the router, hub, modem,etc.)shall be listed,must HPTCOVER:Plug in transformer box for IPGSM communicator. be powered from an un-switched branch circuit,and be pro- BAT-1270:Battery 12 Volts,7 AH,sealed. vided with appropriate standby power. • IPGSM-4G must use the 7AH battery(not supplied)to pro- Agency Listings and Approvals vide 24-hour backup capability. The listings and approvals below apply to the basic IPGSM-4G communicator panel.In some cases,certain modules may not be Electrical Specifications listed by certain approval agencies,or listing may be in process. Transformer- Consult factory for latest listing status. —Primary 120VAC,60Hz,0.5A. UL Listed:S789. —Secondary:18VDC,50VA. CSFM:7300-1645:0199. Battery: FDNY:COA#6219. Page 2 of 3—DH-60769:13.9/16/16 www honeywell.com This document is not intended to be used for installation purposes We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. ©2016 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited Automation and,Control Solutions Honeywell Honeywell 12 Clintonville Road 1(877)HPP-POWR Northford,CT 06472-1610 hpp_techsery@honeywell.com www.honeywelipower.com DH-60769 D September 2016 Madein the S A 'Q 0 9001 O U S Registered Trademark V ©2016 Honeywell International Inc 9331INL Page 3ot3 QUALITY SYSTEMS INTELLIKNIGHT ACCESSORY 3SILENT SK-Fire-CO KNIGHT 0 Advanced Combination by Honeywell Fire and CO Detector SK-Fire-CO offers world-class fire and carbon monoxide (CO) detection combined in a single addressable device to provide a practical and cost-effective solution for today's market. For more information about the SK-Fire-CO, or to locate you nearest source, please call 800-328-0103. SK-FIRE-CO The SK-Fire-CO is a plug-in, addressable device that provides both fire and carbon monoxide (CO) detection. For fire, the detector combines four separate sensing elements in one unit(smoke CO light/flame and heat)to sense multiple components of a fire. This approach enables enhanced sensitivity to real fire with heightened immunity to nuisance particulate. For CO, the detector's electrochemical 3 sensing cell creates a separate signal for life safety CO detection. Released through the incomplete burning of various fuels, CO is a colorless, odorless and deadly gas that is virtually impossible to detect with the human senses. Because the potential exists for dangerous levels of CO to accumulate in almost any building, legislation mandating the use of CO detection in commercial spaces continues to increase across the U.S. and Canada.The SK-Fire-CO is listed to SK-Fire-Co installed in a the UL 2075 standard for system-connected life safety 6200S Sounder Base (sold separately) carbon monoxide monitoring. The SK-Fire-CO should be used in conjunction with the RealTest®CO testing capability B200S intelligent sounder base (sold separately), which can • UL 268 and UL 2075 listed generate either a Temp 3 pattern for fire or a Temp 4 • Separates audible signal for fire or CO alarm pattern for CO alarm indication. With each sounder base when used with the B200S base learning the address of the detector connected, the FACP • CO cell end-of-life warning and fault can then command an individual sounder, or a group of sounders, to activate.The command set from the panel can Compatibility be tailored to the specific event, allowing selection of tone, The SK-Fire-CO is compatible with the following and group. For more information on the B200S refer to Data IntelliKnight FACP's programmed for System Sheet P/N 351183. Sensor protocol: (Firmware version 13.0 or SK-Fire-CO can also be used with the B21OLP 6"standard higher). base, the B200SR sounder base or the B224RB relay base., • 5700 Features • 5808 • 5820XL • Unique ability to detect all four major elements of a fire: • 5820XL-EVS -Smoke -Carbon Monoxide (CO) - Light/flame - Heat • Separate CO detection signal • Highest nuisance alarm immunity •Automatic drift compensation of smoke sensor and CO cell • Uses only one address on the SLC Model SK-Fire-CO Combination Fire and CO Detector Specifications Ordering Information Physical SK-Fire-CO Combination Fire and CO Detector Diameter: 6.875" (17.46 cm) installed in a (base not included) B200S base Height: 3.46" (8.79 cm) installed in Optional Accessories B200S base B200S Intelligent sounder base Shipping Weight: 4.6 oz B21OLP 6" mounting base Color: Ivory B200SR Sounder base B224RB Relay base Operating M02-04-01 Detector test magnet Temperature Range: 32° F to 100° F (0° C to 38° C) M02-09-01 Telescoping test magnet Humidity: 15 to 90% relative humidity (non-condensing) Air Velocity: 0 to 4,000 ft/min (0 to 20 m/sec) Electrical Operating Voltage: 15 to 32 VDC Maximum Standby: 300pA at 24 VDC (no communication every 5 seconds with LED blink enabled) Maximum Alarm Current(LED on): 7.2 mA at 24 VDC CO Monitoring UL Standard Reference-Alarm Thresholds are as follows: Parts er Million Detector Response Time 70 ± 5 ppm 60-240 min. 150 ± 5 ppm 10-50 min. 1 400 ± ppm 4-15 min. Note: Per UL Standard 2075, the SK-Fire-CO has been tested to the sensitivity limits defined in UL Standard 2034. SILENT This document is not intended to be used for installation purposes.We try to Assembles! In America keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are FORM#351181 Rev D subject to change without notice.For more information,contact Silent Knight ©2014 Honeywell International Inc by Honeywell 12 Clintonville Road,Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118.For Technical Support,Please call 800-446-6444. www.silentknight.com INTELLIKNIGHT FIRE ALARM CONTROLPANEL i 3 SILENT Intell!Knight° Model 5820XL 0 KNIGHT Addressable Fire by Honeywell Alarm Control System The IntelliM(night System is the easy way to make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 serial/parallel printer interface module (for printing system reports), and 5895XL intelligent power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol • Built in support for 127 SD devices, expandable to 508 SD devices using the SD protocol. • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator Model 5820XL • Central station reporting by point or by zone • Built-in synchronization for appliances from AMSECO®, 6 amp power supply and maximum Gentex®, Faraday, System Sensor, and Wheelock® charging capacity of amp hours i additional cabinet enclosure is required for • FlexputTM 1/0 circuits batteries in excess of 18 amp hours) • Supports Class B (Style 4) and Class A(Style 6) configuration • Programmable date setting for Daylight for SLC, SBUS, and Flexput circuits Saving Time • 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Installation • Built-in annunciator with 80-character LCD display The 5820XL can be surface or flush • RS-485 bus provides communication to system accessories mounted • Built-in RS-232 and USB interface for programming via PC • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Compatibility • Improvements in SKSS software deliver five times faster The 5820XL signal line circuit (SLC) uploads/downloads supports multiple device types of the same • Two built-in Form C programmable relays rated at 2.5 amps protocol: at 27.4 VDC • SK(System Sensor) • Plex-1 door option combines a dead front cabinet door with a • SD clear window, limiting access to the panel while providing single button operation of the reset and silence functions You cannot mix SD and SK SLC devices on a FRCP. INTELLIKNIGHT FIRE ALARM • RO PANEL IntelliKnight Model 582OXL Addressable Fire Alarm Control Panel Indicator Lights 5820XL features a 6 amp power supply required to start a new system.The General Alarm (Red): Flashes when in and maximum battery charging built-in keypad and 5860 remote alarm;solid when alarm silenced capacity of 35 amp hours.An additional annunciator give on-site access to all cabinet enclosure(PN RBB)is required programming.You can also program Supervisory(Yellow): Flashes when a for batteries in excess of 18 amp hours. remotely using the 5660 Silent Knight supervisory condition exists;solid when Flexput circuits on 5820XL control can Software Suite,which is Windows®- supervisory silenced be individually programmed to function based software. System Troubles (Yellow): Flashes as notification circuits, auxiliary power when a trouble condition exists;solid outputs,or initiation circuits that Built-In Digital Communicator when trouble silenced support both 2-and 4-wire smoke detectors. 5820XL features abuilt-in UL listed System Silenced (Yellow): On when an digital communicator for remote alarm,trouble or supervisory condition The 5820XL system operates on non- twisted, unshielded cable when wired reporting of system activity and system has been silenced but not yet cleared in compliance with standard wiring programming.The communicator has the ability to seize two telephone lines System Power(Green): Flashes for AC practices as called out in the National failure; solid when power systems are Electric Code 760-51 specifications for m report alarms and troubles to a normal power-limited fire protective signalling monitoring facility.The communicator supervises two phone lines and will cables. No special wiring is required. 5820XL provides 13 reset notification activate a trouble signal if a line failure System Application p p is sustained for more than 45 seconds. 5820XL has one built-in signalling line cadence patterns(including ANSI 3.41) Other communication features include: circuit(SLC)which supports multiple and four user programmable selections retry if communication fails,two phone devices dependent on protocol being for fire alarm notification. number capability,download phone used Three additional loops can be Two programmable general purpose number capability and Touch-Tone or added using the 5815XL SLC Form C relay outputs are provided on rotary dialing The communicator is expanders to increase overall capacity. 5820XL. compatible with SIA and Ademco Additionally,the IntelliKnight system Contact ID.The format is selectable by The 5820XL SLC loops support features a built-in walk test and auto- account number. multiple device types, including: programming. Its innovative,dead-front • Addressable photoelectric smoke cabinet design allows for flush or detector surface mounting. System maintenance • Addressable ionization smoke is easy to perform. detector User Interfaces' • Addressable heat sensor The 5820XL built-in annunciator with • Addressable duct smoke detector 80 character LCD display and large ' • Contact module easy-to-use tactile touchpad can be " r • Relay output module used for system operation, + programming and maintenance It has • Addressable notification module five LEDs for alarm,supervisory, • Addressable beam detector(SK system trouble, system silenced and protocol only) system power. System operations • Addressable multi-criteria smoke include silencing alarms and troubles, Approvals detector(SK protocol only) resetting alarms and the display of NFPA 13, NFPA 15, NFPA 16, alarm troubles and memory.The NFPA 72: Central Station; Remote • Addressable multi modules(SK system's non-volatile event history Signalling; Local Protective Signalling protocol only) buffer stores 1000 events for viewing Systems;Auxiliary Protected Premises The following advanced sensor from the built-in or remote annunciator. Unit; &Water Deluge Releasing capabilities are available with 5820XL: System operation can be initiated with Service.Suitable for automatic, a mechanical firefighter's key or a valid manual,waterflow, sprinkler • Automatic drift compensation 4-to 7-digit operator's code. • Maintenance alert supervisory(DACT non-coded) Programming signalling services. • Built-in sensor test to comply with The IntelliKnight system offers several Other Approvals: UL Listed; NFPA 72 calibration testing options to simplify and speed up CSFM 7170-0559: 135; requirements programming.The JumpStart@ feature MEA 429-92-E Vol.VI; FM Approved minimizes programming IA. CONTROL PANEL IntelliKnight Model 5520XL Addressable Fire Alarm Control Panel IntelliKnight 5820XL "`"�ahty Addressable Fire Alarm System Management ScaRware SK(System Sensor) Protocol Devices 1Mndows Based Up/Download Software �' � ► Compatible CS Receiver tomatlan W Software 6820XL SK-2/2UD Connection UsorAlarm IP Communicator 5895XL _ Irtalligent Porver Mpdule JL3 PeRys 3 Flom L RH:v[n _ OQLVN Ewn[Pliniti = Parallel 5815XLRS]3� SLC E—rder 5860 5824 Romolc Annunootor PnntFrfGModulo '.ti*c-+•�'�i , ' "+. J (1 LrnlA NIWOSy2Pm) y 6Flexput" I/O Circuits - w ;� •5 XL °�w �.�'��° n can be Inputs sLcPp ar outputs 6 Flexput" 6 I/O Circuits can be Inputs _ p1 I oroutputs tells Burnes nm,s amm'r, 1 Punstaeom cm�zlmonal sw nrn snara m_�nvs d; fi .: SK-IonSKA7onitor SK-Iso SK-Control-6 SK•CoMrol B200.SR SK•Acdlmate SKZoneb a,i�o;�;°9°iv,g P.dcr—s'do Adde—bre Fwll lsolatDr Addy a able SLponlsoci Sounder Mubcnleno Zone ,.:,..,.. ».. IrllyxA- Monitor MrJul= Naficeoon Cb .l 13— srrruo Interface 5860 r' �gry DaKto' fModWO moc.'s Module dotGaor ModA Remote AM uoator 4 t SK-Photo SK-Monftor-2 •-Relaymon-2 SK-Head B224RB B224B1 B210LP SK-Photo-T Dual Moncor Adorn atle SK-Heat-ROR Relal/ —An "aecm 5880 Addee-de M^_dule Dud Monrtar SK-Heat-HT 13— ea;a Base LED Coiter& Fhotodednc VVfr-RAys Addressable lo=Modulo Detecta Hea[dWictms _ I I 5883 Rr/ay Intedae Mahle 3K•Beam SK•111lon•10 SK-PtdI-DA SKDuct SK-Mhimon SK-Relay-6 SK-Zone SK42eday SK43eani Add'oomblo SK-Pull-SA Ad]'essaNe Wdeor RolayC onvol Add'e;aebla Adj-s.blo Addrocsoblo Manua Addr.sa. Duo[ M.dule Module Interface Raay r" Be am Data'W Module Pull S+ouon DetWof Mafl,Ja Modula I I ————— I 58854 or 5885.3 Use the 5880 to control up td4 _ I lFn AmuSna0ii) 5883 Relay Interface Modules I qa> INTELLIKNIGHT FIRE ALARM CONTROL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Specifications S-BUS Accessories Miscellaneous Accessories Electrical 5860/11 Remote Fire Annunciator 5660 Silent Knight Software Suite Primary AC: Features the same 80 character backlit (SKSS) 120 VRMS at 50/60 Hz,2.5A or LCD display keypad and firefighter's User-friendly Windows software for 240 VRMS at 50/60 Hz, 1.4A keyswitch as the 5820XL. 5860 is gray remote programming of 5820XLs using Total Accessory Load:6A @ 27 4 VDC, and 5860R is red. a PC. Upload and view panel account power-limited 5815XL Signal Line Circuit Expander information,event history, and detector Standby Current:215 mA The SLC expander is used to add more status. Alarm Current: 385 mA addressable devices to the IntelliKnight 5670 Silent Knight Software Suite system 5820XL supports three (SKSS) Flexput Circuits: 5815XUs. Each 5815XL can support 99 Powerful end-user facility management Six programmable circuits which can be SK detectors and 99 SK modules or software allows viewing of detector programmed_individually as: 127 SD devices. status and event history via modem or Notification circuits:3A @ 27.4 VDC 5895XL Intelligent Power Module direct connection. per circuit, power-limited Adds 6 amps of power, 6 Flexput 1/0 Plex-1 Auxiliary power circuits: 3A @ 27AVDC circuits and 2 Form C.relay circuits to a Dead front cabinet door with clear per circuit, power-limited 5820XL system. window to limit access to the FACR Initiation Circuits: 100 mA @ 27AVDC 5496 Intelligent Power Module RBB per circuit, power limited A 6 amp notification power expander Remote battery box accessory cabinet. that provides four power-limited notifi- Use if backup batteries are too large to Physical cation appliance circuit outputs. fit into FACP cabinet. Dimensions: Flush Mount Dimensions: 5880 LED/10 Module 16"W x 10"H x 6"D 14.5"W x 24.75"H x 3.9"D Features 40 LED outputs, 8 normally (406 mm W x 254 mm H x 152 mm D) (36.8 W x 62.9 H x 9.8 D cm ) open dry contact inputs,and one piezo SD505-DTS-K output. Remote test switch. Used with Overall Dimensions: 5865-3 and 5865-4 SD505-DUCTR. Provides remote key 16.2"W x 26.4"H x 4.2"D Remote LED Annunciator operated test function and annunciation (40.6 W x 67 H x 11.8 D cm) Features 30 programmable LED (15 of detector alarm. red and 15 yellow)outputs, and a piezo SD and SK Devices Weight:28 lbs. (12.8 kg) sounder.The 5865-4 adds a silence See the specification sheets listed Color: Red and reset switch to the package. below for a complete listing of the SD Battery Charging Capacity: 7 0-35 AH 5883 Relay Board and SK devices. Features 10 general purpose Form C 53624 SD Devices Data Sheet Battery Size: 18 AH max allowed in relays. Used with 5880 module. 53623 SK Devices Data Sheet control panel cabinet Larger capacity 5824 Serial/Parallel Printer batteries can be housed in RBB Interface Module accessory cabinet. Provides one parallel and one RS-232 serial port for connecting a printer to Telephone Requirements: the 5820XL. Use to print a real-time log FCC Part 15 and Part 68 approved of system events,detector status Type of Jack: RJ31X(two required) reports,and event history. Interfaces with building control system. This document is not intended to be used for installation purposes We try to keep our SILENT Made in America product information up-to-date and accurate.We cannot cover all specific applications KNIGHT or anticipate all requirements.All specifications are subject to change without notice For more information,contact Silent Knight 12 Clintonville Road,Northford,CT 06472 PN 350210 Rev H2 by.Honeywell Phone (203)484-7161,Fax (203)484-7118.www.silentknight.com ©2012 Honeywell International Inc IntelliKnight&JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight GERTIFICATE OF COMPLIANCE Certificate Number 20130430-S789 _ -'Report Reference S789-20101001 ' Issue Date `: 2012=APRIL-30 Issued to: HONEYWELL SECURITY SUITE 100.. -2 CORPORATE CENTER DR PO BOX 90'40 . MELVILLE NY 11747 = " This-is'to certify that CONTROL UNIT ACCESSORIES;-SYSTEM; CENTRAL representative samples of-,'' .STATION-ALARM UNITS, LOCAL ALARM UNITS; POLICE=STATION;CONNECTED ALARM UNITS; PROPRIETARY ALARM-UNITS ;Fire Alarm'Equipment:, Internet and Digital Cellular Fire. Communicator: Models iPGSM-COM, iPGSM-DP, iPGSM-40 Have been investigated by--UL in-accordance with the Standard(s) ind'icated'omthis Certificate., Standard(s)for Safety: UL864, Control Units and Accessories for,Fire;Alarm Systems' Additional Information: See-the-UL Online Certifications Directory at www.ul.c6'm/d6tabase'f6r'additionaI information ' Only those products bearing the UL Listing Mark should be considered as being,covered by UL's Listing and,Follow-Up Service. The°UL Listing Mark generally includes the following elements:the symbol UL"in a circle: 4i_with the word'"LISTED";,a control number;(may be;alphanumeric),assigned by,UL; and,the product category 'name'(product identifier).as indicated in the appropriate UL Directory. ' Look,for the UL Listing Mark on the product. This is to certify that representative samples of the product as specified on this certificate were tested according to the-current'UL_requirements. - _ U • William R.Camey,Director,Notth'Amedran Certlfieallon Programs Any Information and documentation Involving UL Mark services are provided on behalf of UL LLC(UL)or any,auttionzed licensee of UL.For questions,please contact a local UL Customer Service Representative at www ul comlcontectus - ' Page 1 of-1 ; O www.nye gov/fdny CERTIFICATE OF APPROVAL # 6219 THIS CERTIFICATE IS REVOCABLE, NOT TRANSFERABLE and EXPIRES on MARCH 3 , 2019 By order of Fire Commissioner Daniel A. Nigro, and pursuant to Section FC 112 of the New York City New Fire Code,the following equipment or system is accepted for use provided the conditions as outlined below are in full compliance. Manufacturer: Honeywell International,Inc. Trade Name(s): Honeywell Security Product: Commercial Fire Communicators IPGSM-DP,IPGSM-4G Pertinent Code Section FC901 of New York City New Fire Code Section(s): Prescribed UL 864—9"Edition,NFPA 72 Test(s): Laboratory: Underwriters Laboratories,Inc. Test Report(s): UL File S789 Vol.24 Sec.3,issued 2010-10-01,revised 2014-05-16 Description: Honeywell's models IPGSM-DP(COA#6133)and IPGSM-4G are Internet and Digital Cellular Fire Communicators/Transmitters designed to transmit status of FACP to Central Station via Internet or Cellular network. All signals from the IPGSM-DP and IPGSM-4G are delivered to Honeywell's AlarmNet Control Center,which routes the information to the approved Central Station,using Contact ID communication format as described in the SIA DC-05 Standard.The IPGSM- DP and IPGSM-4G use the Internet as its primary reporting path,and use GSM cellular reporting path as a backup. In addition,each communicator utilizes power module that monitors and reports AC power loss,low battery,and missing battery connection to Central Station. The IPGSM-DP and IPGSM-4G models are compatible with all UL 864 9-th edition FDNY/MEA-approved Fire Alarm Control Panels that use the Contact ID communication format. Conditions of Approval: 1. All uses, configurations, arrangements and functions, application and installations shall comply with the provisions of New York City Construction Codes, specifically Building Code Chapter 9 & 1RCNY §3616- 04. Further, the installation shall be in accordance with applicable provisions of New York City Fire Code, New York City Electrical Code,manufacturer's installation requirements,)and UL Standard 864. Fire Department, City of New York EXPIRES on MARCH 3,2019 COA#6219 for Honeywell Security F.P.Index#: 1512002A FPIMS#:35359348 March 4,2016 Page 2 of 3 2. When used with a central office control communicator or a transmitter,the installation and operation of the equipment and devices shall comply with 3RCNY §901-01. It shall have the capability of transmitting separate and distinct signals to indicate manual pull station alarm, automatic detection alarm, sprinkler waterflow alarm,supervisory signal indications,and trouble indications. 3. When installed as a Central Station Internet/Cellular communicators IPGSM-DP, IPGSM-4G, both primary and secondary channels of communication shall be required and shall meet the conditions of 3.1 –3.7. Network communication shall be used as Primary channel of communication with Central Station and Cellular Communicator shall be used as the secondary channel of communication or in reverse order:Cellular Communicator as primary and Internet connection as the secondary channel. 3.1.Each communication channel shall be monitoring for integrity at intervals not exceeding 24 hours 3.2.Failure of any channel of communication shall be annunciated at the protected premises within 5 minutes of failure 3.3.When any channel of communication has failed,a trouble signal shall be sent to Central Station within 5 minutes of failure by the remaining active channel. 3.4.Reliability of the signal shall be achieved by any of the following: 3.4.1.Signal repetition—multiple transmissions repeating the same signal 3.4.2.Parity check--a mathematically check sum algorithm of a digital message that verifies correlation between transmitted and received message. 3.4.3.An equivalent means that provides a certainty of 99.99 percent that the received message is identical to the transmitted message 3.5.The maximum duration between,the initiation of an alarm signals at the protected premises, ,transmission of the signal, and subsequent display and recording of the alarm signal at the Central Station shall not exceed 90 seconds 3.6.A spare Central Station Receiver shall be provided at the Central Station and shall be able to be switched into the place of a failed unit within 30 seconds after detection of failure 3.7.All applicable requirements of Federal Communications Commission(FCC)shall be complied with. 4. All communication devices such as the routers, wiring, antenna, etc shall be installed for communication and transmission of fire alarm system signals and shall be properly secured at all times from unauthorized use. All wiring used for network communications shall be plenum rated cable with a minimum temperature rating of 150°C and shall be installed in raceway as per requirements of NYC Electrical Code,Article 760. 5. Underwriters Laboratories Inc.'s Listing requirements and limitations shall be complied with. 6. The above referenced communicator shall be used only with listed fire alarm equipment, which compatibility has been determined by Underwriters Laboratories test reports. 7. 11 installations are subject to inspection,test,and approval from FDNY Fire Alarm Inspection Unit(FAIU). Pa EXPIRES on MARCH 3,2019 COA#6219 for Honeywell Security F.P.Index#: 1512002A FPIMS#:35359348 March 4,2016 Page 3 of 3 8. AlarmNet Control Center may be subject of FDNY inspection. All inspection shall be conducted during normal business hours. 9. Any change in Central Station communication service provider shall be reported to FAIU and is subject to re-inspection,test,and approval. 10. Certificate of Approval number shall be plainly and permanently stamped or otherwise fixed upon each product by the applicant. 11. The Fire Department's conditions of approval shall be enumerated in the installation manuals and brochures or in the product packaging documents that will be provided to all New York City buyers and users. 12. Fire Department Certificate of Approval does not constitute an endorsement or recommendation of your product by the Fire Department, but is a certification that your product is acceptable as of the date of issuance. 13. The Fire Department reserves the right to withdraw this approval at any time in the event there is a reasonable doubt that the product does not operate or perform as required by code, the conditions of this resolution or as represented in your application. 14. As the manufacturer of this product, you should be aware that any end user who fails to comply with the condition as outlined in the approval would be subject to enforcement action, which may include fines and imprisonment. Any change in company name or ownership, product name, design or model number of any product included on this certificate must be immediately reported to this Department in writing. When responding to this Department regarding this subject matter,kindly refer to F.P.Index# 1512002 and to Igor Chouchereba attention,9 MetroTech Center#15-43-K,phone(718)999-1997. 4ji yours,,—/—,,K.J s h Deputy Director of Engineering Technology Management c: Tamara Saakian,Director of Technology Management SJ:IC/1512002 DevicelD Alarm DateTimeGMT AlarmCode Description Origin OOD02DC7EE3C 2017-05-26 06:04:25 E60200000 E-602-Periodic test report Ethernet OOD02DC7EE3C 2017-05-25 18:15:31 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-25 18:12:11 R33300001 R-333-Expansion module failure Ethernet OOD02DC7EE3C 2017-05-25 18:10:47 E33300001 E-333-Expansion module failure Ethernet OOD02DC7EE3C 2017-05-25 18:10:41 E30500000 E-305-System reset Ethernet OOD02DC7EE3C 2017-05-25 18:10:35 E62800000 E-628-Program mode exit Ethernet OOD02DC7EE3C 2017-05-25 18:07:50 E62700000 E-627-Program mode entry Ethernet OOD02DC7EE3C 2017-05-25 18:07:36 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-25 18:00:24 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-25 18:00:18 E37333006 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 18:00:12 E37333005 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 18:00:07 E37333004 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 18:00:03 E37333003 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 18:00:00 E37333002 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:59:54 E37333001 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:59:12 R37333276 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:58:57 R37333286 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:58:52 R37333285 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:58:47 E37333286 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:58:36 E37333285 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:57:28 R37333286 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:57:24 R37333285 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:56:00 E37333286 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:55:54 E37333285 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:55:44 R37333286 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:55:37 R37333285 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:55:33 E37333286 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:55:27 E37333285 E-373-Fire trouble Ethernet OOD02DC7EE3C, 2017-05-25 17:44:12 R37333002 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:42:36 R37333001 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:41:15 R37333003 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:40:19 R37333004 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:39:01 R37333005 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:38:04 R37333006 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:34:10 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-25 17:34:00 E37333087 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:33:54 E37333010 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:33:50 E37333009 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:33:43 E37333008 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:33:38 E37333007 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 17:33:31 E37333006 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:22:08 R37333006 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:18:26 R37333008 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:16:35 R37333007 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:14:19 R37333009 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:12:18 R37333010 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:10:17 R37333087 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:10:11 JE37333004 I E-373-Fire trouble jEthernet OOD02DC7EE3C 2017-05-25 15:10:06 E37333002 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:10:01 E37333095 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:09:50 E37333094 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:09:45 E37333093 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:09:41 E37333092 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:09:34 E37333091 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:09:29 E37333090 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:09:25 E37333087 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:09:19 E37333084 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:09:09 E37333083 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:09:03 E37333082 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:08:59 E37333081 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:08:54 E37333080 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:08:48 E37333026 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:08:42 E37333025 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:08:37 E37333024 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:08:32 E37333023 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:08:25 E37333022 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:08:20 E37333021 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:08:15 E37333020 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:08:08 E37333019 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:07:58 E37333018 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:07:51 E37333017 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:07:46 E37333016 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:07:41 E37333015 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:07:35 E37333014 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:07:31 E37333012 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:07:26 E37333011 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:07:20 E37333010 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:07:16 E37333009 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:07:10 E37333008 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:07:06 E37333007 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:07:00 E37333006 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:06:55 E37333005 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:06:48 E37333003 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:06:44 E37333001 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:06:15 E37333276 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:06:11 E33300001 E-333-Expansion module failure Ethernet OOD02DC7EE3C 2017-05-25 15:06:07 E30500000 E-305-System reset Ethernet OOD02DC7EE3C 2017-05-25 15:06:04 E41200000 E-412-Successful download/access Ethernet OOD02DC7EE3C 2017-05-25 15:04:14 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-25 15:04:04 E33300001 E-333-Expansion module failure Ethernet OOD02DC7EE3C 2017-05-25 15:03:58 E37333084 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:03:48 E37333083 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:03:42 E37333081 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:03:37 E37333080 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:03:30 E37333011 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 15:03:25 E37333010 E-373-Fire trouble Ethernet 0OD02DC7EE3C 2017-05-25 15:03:02 JE41300000 I E-413-Unsuccessful access Ethernet OOD02DC7EE3C 2017-05-25 14:35:00 R37333010 R-373-Fire trouble Ethernet - OOD02DC7EE3C 2017-05-25 14:34:06 R37333011 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:27:03 R37333080 R-373-Fire trouble. Ethernet OOD02DC7EE3C 2017-05-25 14:26:31 R37333081 R-373-Fire trouble Ethernet OOD02DC7EE3C 201705-25 14:25:44 R37333084 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:25:13 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-25 14:25:07 R37333083 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:24:57 E37333017 E-3734ire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:24:47 E37333016 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:24:42 E37333015 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:24:37 E37333014 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:24:30 E37333012 E-373-Fire trouble Ethernet 'OOD02DC7EE3C 2017-05-25 14:24:25 E37333011 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:18:28 R37333011 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:17:41 R37333012 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:17:01 R37333014 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:16:05 R37333015 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:15:19 R37333016 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:14:24 R37333017 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:08:59 E37333004 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:08:54 E37333002 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:08:48 E37333095 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:08:43 E37333094 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:08:33 E37333093 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:08:27 E37333092 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:08:22 E37333091 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:08:11 E37333090 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:08:07 E37333087 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:07:55 E37333084 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:07:43 E37333083 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:07:38 E37333082 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:07:12 E37333081 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:07:06 E37333080 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:07:03 E37333026 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:06:55 E37333025 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:06:49 E37333024 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:06:38 E37333023 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:06:22 E37333022 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:06:11 E37333021 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:06:01 E37333020 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:05:56 E37333019 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:05:50 E37333018 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:05:45 E37333017 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:05:34 E37333016 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:05:28 E37333015 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:05:12 E37333014 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:05:08 E37333012 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:04:52 E37333011 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-25 14:04:47 JE37333010 E-373-Fire trouble Ethernet OODO2DC7EE3C 2017-05-25 14:04:40 E37333OO9 E-373-Fire trouble Ethernet OODO2DC7EE3C 2017-05-25 14:04:35 E37333OO8 E-373-Fire trouble Ethernet OODO2DC7EE3C 2017-05-25 14:04:25 E37333OO7 E-373-Fire trouble Ethernet OODO2DC7EE3C 2017-05-25 14:04:14 E37333OO6 E-373-Fire trouble Ethernet OODO2DC7EE3C 2017-05-25 14:04:04 E37333OO5 E-373-Fire trouble Ethernet OODO2DC7EE3C 2017-05-25 14:03:58 E37333003 E-373-Fire trouble Ethernet OODO2DC7EE3C 2017-05-25 14:03:53 E37333OO1 E-373-Fire trouble Ethernet OODO2DC7EE3C 2017-05-2514:03:13 E3O5OO000 E-305-System reset Ethernet OODO2DC7EE3C 2017-05-25 14:03:09 E628OO000 E-628-Program mode exit Ethernet OODO2DC7EE3C 2017-05-25 14:02:07 E37333OO2 E-373-Fire trouble Ethernet OODO2DC7EE3C 2017-05-25 14:02:01 E37333OO1 E-373-Fire trouble Ethernet OODO2DC7EE3C 2017-05-25 14:01:35 E627OO000 E-627-Program mode entry Ethernet OODO2DC7EE3C 2017-05-25 14:01:30 E3O5OO000 E-305-System reset Ethernet OODO2DC7EE3C 2017-05-25 14:01:24 E628OO000 E-628-Program mode exit Ethernet OODO2DC7EE3C 2017-05-25 13:58:59 E627OO000 E-627-Program mode entry Ethernet OODO2DC7EE3C 2017-05-25 13:52:25 E4O1OO000 E-401-0/C by user Ethernet OODO2DC7EE3C 2017-05-25 13:52:14 E37333O87 E-373-Fire trouble Ethernet OODO2DC7EE3C 2017-05-25 13:51:26 R37333O87 R-373-Fire trouble Ethernet OODO2DC7EE3C 2017-05-25 13:48:42 E4O1OO000 E-401-0/C by user Ethernet OODO2DC7EE3C 2017-05-25 13:47:30 E37333OO4 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:47:23 E37333OO2 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:47:16 E37333O95 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:47:09 E37333O94 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:47:02 E37333O93 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:46:54 E37333O92 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:46:47 E37333O91 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:46:42 E37333O9O E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:46:39 E37333O87- E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:46:28 E37333O84 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:46:21 E37333O83 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:46:14 E37333O82 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:46:08 E37333O81 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:46:00 E37333O8O E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:45:54 E37333O26 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:45:46 E37333O25 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:45:40 E37333O24 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:45:32 E37333O23 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:45:26 E37333O22 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:45:20 E37333O21 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:45:13 E37333O2O E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:45:07 E37333O19 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:44:59 E37333O18 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:44:51 E37333O17 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:44:45 E37333O16 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:44:38 E37333O15 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:44:31 E37333O14 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:44:25 E37333O12 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:44:19 E37333O11 E-373-Fire trouble Cellular OODO2DC7EE3C 2017-05-25 13:44:13 E37333O1O E-373-Fire trouble Cellular OOD02DC7EE3C 2017-05-25 13:44:05 E37333009 E-373-Fire trouble Cellular OOD02DC7EE3C 2017-05-25 13:43:58 E37333008 E-373-Fire trouble Cellular OOD02DC7EE3C 2017-05-25 13:43:51 E37333007 E-373-Fire trouble Cellular OOD02DC7EE3C 2017-05-25 13:43:44 E37333006 E-373-Fire trouble Cellular OOD02DC7EE3C 2017-05-25 13:43:39 E37333005 E-373-Fire trouble Cellular OOD02DC7EE3C 2017-05-25 13:43:34 E37333003 E-373-Fire trouble Cellular OOD02DC7EE3C 2017-05-25 13:43:25 E37333001 E-373-Fire trouble Cellular OOD02DC7EE3C 2017-05-25 13:42:51 E30500000 E-305-System reset Cellular OOD02DC7EE3C 2017-05-25 13:42:43 E62800000 E-628-Program mode exit Cellular OOD02DC7EE3C 2017-05-25 13:40:03 E62700000 E-627-Program mode entry Cellular OOD02DC7EE3C 2017-05-25 13:39:07 E40100000 E-401-0/C by user Cellular OOD02DC7EE3C 2017-05-25 13:38:17 R35200002 R-352-Telco 2 fault Cellular OOD02DC7EE3C 2017-05-25 13:38:09 R35100001 R-351-Telco 1 fault Cellular OOD02DC7EE3C 2017-05-25 13:35:19 E40100000 E-401-0/C by user Cellular OOD02DC7EE3C 2017-05-25 13:34:26 E35200002 E-352-Telco 2 fault Cellular OOD02DC7EE3C 2017-05-25 13:33:32 E33900803 E-339-Exp. Module Power On/Reset Ethernet OOD02DC7EE3C 2017-05-25 13:23:36 E35100001 E-351-Telco 1 fault Ethernet OOD02DC7EE3C 2017-05-25 13:23:19 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-25 13:20:31 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-25 13:19:28 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-25 06:02:49 E60200000 E-602-Periodic test report Ethernet OOD02DC7EE3C 2017-05-24 22:55:40 R37333010 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 22:54:49 E37333010 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 22:54:19 R37333010 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 22:53:58 E37333010 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:47:09 E30500000 E-305-System reset Ethernet OOD02DC7EE3C 2017-05-24 20:47:03 E62800000 E-628-Program mode exit Ethernet OOD02DC7EE3C 2017-05-24 20:45:30 E62700000 E-627-Program mode entry Ethernet OOD02DC7EE3C 2017-05-24 20:42:42 E30500000 E-305-System reset Ethernet OOD02DC7EE3C 2017-05-24 20:42:38 E62800000 E-628-Program mode exit Ethernet OOD02DC7EE3C 2017-05-24 20:40:23 E62700000 E-627-Program mode entry Ethernet OOD02DC7EE3C 2017-05-24 20:40:06 E37333001 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:40:00 E30500000 E-305-System reset Ethernet OOD02DC7EE3C 2017-05-24 20:39:55 E62800000 E-628-Program mode exit Ethernet OOD02DC7EE3C 2017-05-24 20:38:41 E62700000 E-627-Program mode entry Ethernet OOD02DC7EE3C 2017-05-24 20:38:34 R60400000 R-604-Fire test Ethernet OOD02DC7EE3C 2017-05-24 20:38:28 E60400000 E-604-Fire test Ethernet OOD02DC7EE3C 2017-05-24 20:38:13 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-24 20:38:07 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-24 20:37:57 R37333299 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:37:53 R57133299 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:37:32 R37333298 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:37:26 R57133298 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:37:21 R37333297 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:37:16 R57133297 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:37:06 R37333296 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:36:59 R57133296 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:36:50 R37333289 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:36:42 R57133289 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:36:37 R37333288 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:36:27 R57133288 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:36:21 R37333286 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:36:15 R57133286 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:36:05 R37333285 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:35:48 R57133285 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:35:43 R37333279 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:35:37 R57133279 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:35:27 R37333278 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:35:11 R57133278 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:35:05 R37333277 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:34:52 R57133277 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:34:44 R37333095 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:34:38 R57133095 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:34:23 R37333094 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:34:16 R57133094 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:34:07 R57133094 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:33:51 R37333093 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:33:47 'R57133093 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:33:41 R37333092 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:33:34 R11533286 R-115-Pull Station Ethernet OOD02DC7EE3C 2017-05-24 20:33:23 R16233001 R-162-Carbon Monoxide detected Ethernet OOD02DC7EE3C 2017-05-24 20:33:18 R57133092 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:33:08 R37333091 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:33:02 R57133091 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:32:51 R37333090 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24,20:32:47 R57133090 R-571-Fire bypass _ Ethernet OOD02DC7EE3C 2017-05-24 20:32:40 R37333087 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:32:30 R57133087 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:32:25 R37333084 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:32:19 R57133084 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:32:13 R37333083 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:32:08 R57133083 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:32:02 R37333082 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:31:56 R57133082 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:31:51 R57133082 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:31:46 R37333081 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:31:35 R57133081 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:31:31 R37333080 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:31:19 R57133080 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:31:14 R37333026 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:31:09 R57133026 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:31:02 R37333025 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:30:57 R57133025 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:30:47 R37333024 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:30:42 R57133024 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:30:36 R37333023 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:30:31 R57133023 R-571-Fire bypass Ethernet 0OD02DC7EE3C 2017-05-24 20:30:21 JR37333022 I R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:30:18 R57133022 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:30:10 R37333021 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:30:00 R57133021 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:29:50 R37333020 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:29:45 R57133020 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:29:39 R37333019 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:29:33 R57133019 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:29:27 R37333018 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:29:22 R57133018 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:29:11 R37333017 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:29:01 R57133017 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:28:50 R37333016 R-373-Fire trouble Ethernet OOD02DC7EE3C' 2017-05-24 20:28:44 R57133016 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:28:24 R37333015 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:28:07 R57133015 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:27:52 R37333014 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:27:37 R57133014 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:27:31 R37333012 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:27:26 R57133012 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:27:20 R37333011 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:27:11 R57133011 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:27:04 R37333010 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:27:00 R57133010 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:26:55 R37333009 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:26:48 R57133009 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:26:39 R37333008 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:26:24 R57133008 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:26:19 R37333007 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:26:13 R57133007 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:26:10 R37333006 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:26:04 R57133006 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:25:58 R37333005 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:25:54 R57133005 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:25:43 R37333004 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:25:38 R57133004 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:25:32 R37333003 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:25:27 R57133003 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:25:21 R37333002 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:25:10 R57133002 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:25:05 R37333001 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:24:59 R57133001 R-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:24:53 E57133299 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:24:48 E37333299 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:24:42 E57133298 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:24:38 E37333298 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:24:24 E57133297 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:24:19 E37333297 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:24:14 E57133296 E-571-Fire bypass Ethernet 0OD02DC7EE3C 2017-05-24 20:24:09 IE37333296 I E-373-Fire trouble lEthernet OOD02DC7EE3C 2017-05-24 20:24:03 E57133289 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:23:57 E37333289 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:23:51 E57133288 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:23:45 E37333288 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:23:40 E57133286 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:23:35 E37333286 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:23:31 E57133285 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:23:26 E37333285 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:23:11 E57133279 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:23:05 E37333279 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:22:58 E57133278 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:22:50 E37333278 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:22:46 E57133277 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:22:39 E37333277 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:22:31 E57133095 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:22:25 E37333095 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:22:21 E57133094 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:22:03 E37333094 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:21:57 E57133093 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:21:52 E37333093 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:21:49 E57133092 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:21:44 E37333092 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:21:36 E57133091 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:21:30 E37333091 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:21:26 E57133090 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:21:19 E37333090 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:21:13 E57133087 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:21:05 E11533286 E-115-Pull Station Ethernet OOD02DC7EE3C 2017-05-24 20:20:52 E37333087 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:20:44 E57133084 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:20:39 E37333084 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:20:28 E57133083 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:20:18 E37333083 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:20:13 E57133082 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:20:09 E37333082 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:20:03 E57133081 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:19:58 E37333081 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:19:52 E57133080 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:19:47 E37333080 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:19:36 E57133026 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:19:15 E37333026 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:19:10 E57133025 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:19:05 E37333025 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:19:00 E57133024 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:18:55 E37333024 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:18:45 E57133023 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:18:38 E37333023 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:18:28 E57133022 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:18:21 E37333022 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:18:05 E57133021 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:17:56 E37333021 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:17:49 E57133020 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:17:38 E37333020 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:17:28 E57133019 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:17:21 E37333019 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:17:16 E57133018 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:17:07 E37333018 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:17:01 E57133017 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:16:49 E37333017 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:16:39 E57133016 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:16:33 E37333016 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:16:28 E57133015 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:16:18 E37333015 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:16:03 E57133014 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:15:57 E37333014 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:15:50 E57133012 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:15:44 E37333012 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:15:39 E57133011 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:15:34 E37333011 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:15:24 E57133010 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:15:14 E37333010 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:15:09 E57133009 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:14:58 E37333009 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:14:47 E57133008 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:14:32 E37333008 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:14:26 E57133007 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:14:21 E37333007 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:14:16 E57133006 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:14:11 E16233001 E-162-Carbon Monoxide detected Ethernet OOD02DC7EE3C 2017-05-24 20:14:00 ' E37333006 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:13:54 E57133005 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:13:49 E37333005 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:13:44 E57133004 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:13:32 E37333004 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:13:27 E57133003 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:13:18 E37333003 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:13:12 E57133002 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:13:01 E37333002 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:12:50 E57133001 E-571-Fire bypass Ethernet OOD02DC7EE3C 2017-05-24 20:12:45 E37333001 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:10:14 R37333087 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:07:40 E37333087 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 20:02:03 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-24 20:01:57 R11033087 R-110-Fire Ethernet OOD02DC7EE3C 2017-05-24 20:01:06 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-24 20:00:43 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-24 20:00:19 E40100000 E-401-0/C by user Ethernet 0OD02DC7EE3C 2017-05-24 19:59:32 JE40100000 I E-401-0/C by user lEthernet OOD02DC7EE3C 2017-05-2419:58:48 E11033087 E-110-Fire Ethernet OOD02DC7EE3C 2017-05-2419:54:20 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-2419:54:14 R11033087 R-110-Fire Ethernet' OOD02DC7EE3C 2017-05-24 19:54:08 R16233087 R-162-Carbon Monoxide detected Ethernet OOD02DC7EE3C 2017-05-2419:53:37 E11033087 E-110-Fire Ethernet OOD02DC7EE3C 2017-05-2419:53:31 E16233087 E-162-Carbon Monoxide detected Ethernet OOD02DC7EE3C 2017-05-2419:50:49 R37333087 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 19:50:32 E37333087 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-24 19:49:31 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-24 19:48:54 E30500000 E-305-System reset Ethernet OOD02DC7EE3C 2017-05-2419:48:49 E62800000 E-628-Program mode exit Ethernet OOD02DC7EE3C 2017-05-24 19:43:42 E62700000 E-627-Program mode entry Ethernet OOD02DC7EE3C 2017-05-2419:41:54 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-2419:40:34 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-24 19:40:29 R11533298 R-115-Pull Station Ethernet OOD02DC7EE3C 2017-05-24 19:40:23 R11533278 R-115-Pull Station Ethernet OOD02DC7EE3C 2017-05-2419:26:04 E11533278 E-115-Pull Station Ethernet OOD02DC7EE3C 2017-05-2419:24:37 E11533298 E-115-Pull Station Ethernet OOD02DC7EE3C 2017-05-24 19:23:52 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-2419:23:42 R11533297 R-115-Pull Station Ethernet OOD02DC7EE3C 2017-05-24 19:22:22 E11533297 E-115-Pull Station Ethernet OOD02DC7EE3C 2017-05-24 06:01:35 E60200000 E-602-Periodic test report Ethernet OOD02DC7EE3C 2017-05-23 20:17:51 R33300001 R-333-Expansion module failure Ethernet OOD02DC7EE3C 2017-05-23 20:17:45 E33300001 E-333-Expansion module failure Ethernet OOD02DC7EE3C 2017-05-23 20:17:39 R33300001 R-333-Expansion module failure Ethernet OOD02DC7EE3C 2017-05-23 20:15:10 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-23 20:14:40 E33300001 E-333-Expansion module failure Ethernet OOD02DC7EE3C 2017-05-23 20:14:35 E30500000 E-305-System reset Ethernet OOD02DC7EE3C 2017-05-23 20:14:30 E62800000 E-628-Program mode exit Ethernet OOD02DC7EE3C 2017-05-23 20:11:13 E62700000 E-627-Program mode entry Ethernet OOD02DC7EE3C 2017-05-23 20:08:23 E62500000 E-625-Time/Date reset Ethernet OOD02DC7EE3C 2017-05-23 20:08:17 , E62500000 E-625-Time/Date reset Ethernet OOD02DC7EE3C 2017-05-23 20:07:59 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-23 19:52:37 E30500000 E-305-System reset Ethernet OOD02DC7EE3C 2017-05-23 19:51:24 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-23 19:48:48 E30500000 E-305-System reset Ethernet OOD02DC7EE3C 2017-05-23 19:48:38 E62800000 E-628-Program mode exit Ethernet OOD02DC7EE3C 2017-05-23 19:42:59 E62700000 E-627-Program mode entry Ethernet OOD02DC7EE3C 2017-05-23 19:27:48 R37333087 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 19:26:45 E37333087 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 19:23:15 R37333012 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 19:19:04 E40100000 E-401-0/C by user Ethernet OOD02DC7EE3C 2017-05-23 19:19:00 R11533277 R-115-Pull Station Ethernet OOD02DC7EE3C 2017-05-23 19:17:57 E11533277 E-115-Pull Station Ethernet OOD02DC7EE3C 2017-05-23 19:17:51 R37333095 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 19:17:46 R37333093 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 19:17:32 R37333092 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 19:17:26 R37333090 R-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 19:10:57 E37333095 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 19:10:47 E37333093 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 19:10:16 E37333092 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 19:10:11 E37333090 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 19:10:05 E37333012 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 19:09:28 E30500000 E-305-System reset Ethernet OOD02DC7EE3C 2017-05-23 19:09:23 E62800000 E-628-Program mode exit Ethernet OOD02DC7EE3C 2017-05-23 18:54:11 E62700000 E-627-Program mode entry Ethernet OOD02DC7EE3C 2017-05-2318:51:25 E32034001 E-320-Sounder/Relay Ethernet OOD02DC7EE3C 2017-05-23 18:45:55 E37333004 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:45:50 E37333003 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:45:44 E37333095 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:45:37 E37333094 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:45:22 E37333093 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:45:19 E37333092 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:45:14 E37333091 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:45:09 E37333090 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:45:02 E37333087 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:44:58 E37333084 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:44:53 E37333083 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:44:48 E37333082 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:44:42 E37333081 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:44:37 E37333080 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:44:32 E37333026 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:44:22 E37333025 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:44:17 E37333024 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:44:12 E37333023 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:44:07 E37333022 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:44:00 E37333021 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:43:55 E37333020 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:43:50 E37333019 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:43:44 E37333018 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:43:39 E37333017 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:43:34 E37333016 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:43:29 E37333015 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:43:23 E37333014 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:43:18 E37333012 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:43:12 E37333011 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:43:07 E37333010 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:43:00 E37333009 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:42:54 E37333008 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:42:51 E37333007 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:42:44 E37333006 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:42:38 E37333005 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:42:33 E37333002 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:42:27 E37333001 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-2318:42:22 R32034002 R-320-Sounder/Relay Ethernet OOD02DC7EE3C 2017-05-2318:41:54 E32034002 E-320-Sounder/Relay Ethernet OOD02DC7EE3C 2017-05-23 18:41:49 E30500000 E-305-System reset Ethernet OOD02DC7EE3C 2017-05-23 18:41:44 E62800000 E-628-Program mode exit Ethernet OOD02DC7EE3C 2017-05-23 18:35:51 E62700000 E-627-Program mode entry Ethernet OOD02DC7EE3C 2017-05-23 18:35:42 E62500000 E-625-Time/Date reset Ethernet OOD02DC7EE3C 2017-05-23 18:35:37 E62500000 E-625-Time/Date reset Ethernet OOD02DC7EE3C 2017-05-23 18:35:30 E37333004 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:35:25 E37333002 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:35:14 E37333095 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:35:09 E37333094 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:34:58 E37333093 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:34:55 E37333092 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:34:48 E37333091 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:34:42 E37333090 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:34:32 E37333087 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:34:26 E37333084 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:34:20 E37333083 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:34:15 E37333082 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:34:10 E37333081 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:34:03 E37333080 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:33:58 E37333026 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:33:50 E37333025 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:33:43 E37333024 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:33:33 E37333023 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:33:27 E37333022 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017705-23 18:33:22 E37333021 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:33:18 E37333020 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:33:06 E37333019 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:33:00 E37333018 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:32:53 E37333017 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:32:49 E37333016 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:32:42 E37333015 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:32:36 E37333014 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:32:30 E37333012 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:32:26 E37333011 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:32:21 E37333010 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:32:14 E37333009 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:32:08 E37333008 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:32:03 E37333007 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:31:47 E37333006 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:31:38 E37333005 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:31:32 E37333003 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:31:29 E37333001 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:30:51 E30500000 E-305-System reset Ethernet OOD02DC7EE3C 2017-05-23 18:30:46 E62800000 E-628-Program mode exit Ethernet OOD02DC7EE3C 2017-05-23 18:28:31 E37333095 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:28:27 E37333093 E-373-Fire trouble Ethernet OOD02DC7EE3C_ 2017-05-23 18:28:21 E37333092 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:28:15 E37333090 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:28:05 E37333012 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-23 18:28:00 E62700000 E-627-Program mode entry Ethernet 0OD02DC7EE3C 2017-05-23 18:27:29 IE30500000 1 E-305-System reset lEthernet OOD02DC7EE3C 2017-05-23 18:27:19 E62800000 E-628-Program mode exit Ethernet OOD02DC7EE3C 2017-05-19 15:50:07 E62700000 E-627-Program mode entry Ethernet OOD02DC7EE3C 2017-05-19 15:49:38 E30500000 E-305-System reset Ethernet OOD02DC7EE3C 2017-05-19 15:49:33 E37333001 E-373-Fire trouble Ethernet OOD02DC7EE3C 2017-05-19 15:49:28 IE62800000 E-628-Program mode exit Ethernet OOD02DC7EE3C 2017-05-19 14:47:20 JE33900803 E-339-Exp. Module Power On/Reset Ethernet OOD02DC7EE3C 2017-05-19 14:46:59 JOODOOIOCO Substitution or Registration Alarmnet Data Center DRAWING LIST ` GENERAL SOUND VIEW % ND IEW IiNN CVR COVER SHEET, KEY PLAN & DRAWING LIST I N N %..j U V RENOVATION GREENPORT, N 11944 ARCHITECTURAL ffROVED AS NOTED GREENPORT, N.Y. 11944 A-A1.0:TYPICAL DEMOLITION AND CONSTRUCTION PLAN: MODEL UNIT#25 DATE:I I ill 91/k,BY # 2�— A-A1.1:TYPICAL DEMOLITION AND CONSTRUCTION PLAN: MODEL UNIT#18FEE: �f ����� gy; r� b Id architecture, d pc A-A1.2:TYPICAL DEMOLITION AND CONSTRUCTION PLAN: MODEL UNIT#17 NOTIFY BUILDING DEPART ENf AT 31 West Main Street,Suite 205 A-A1.3:TYPICAL DEMOLITION AND CONSTRUCTION PLAN: MODEL UNIT#1 -16 765-1802 8 AM TO 4 PM FOR THE Patchogue, NY 11772 FOLLOWING INSPECTIONS: TFL:631 580 2100 1. FOUNDATION - TWO REQUIRED FAX.631 580 9760 FOR POURED CC^;CRETE www.baidassano.com 2. ROUGH - FRAMING & FLUME NG 3. INSULATION DESIGNER: 4. FINAL - CONSTRUCTION MUST Studio Tack BE COMPLETE FOO, C.O. ALL CONSTRUCTON SHALL MEET THE 197 Plymouth street LEVEL 1 ALTERATION - BLDG 'A' REQUIREMENTS OF THE CODES OF P�Ed�, Brooklyn, NY 11201 YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. ISSUED FOR PERMIT COMPLY WITH ALL CODES OF NOVEMBER 18, 2016 NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF FLUIUIB -R CER TIF1CATION ONLEAL 1 CONTENT BEFC E SOUTHOl:{}T{ WPLANN't,3BOARD CERTIFIC ATE OF OCCUPANT Y SOUTH01.D70MTRUSTEES- SOLD C?USED IN 6^JATE;q N.Y.S.DEC SUPPL 'SYSTEM CA NNG i EXCEE 2/10 OF 15a L`AD. OCCUPANCYOR gw aUr�BIr� USE IS UKI it rFUL ALL -U%,1E "!G WASTE WITHOUT CERTIFICATE & N �ER LINES NErED '" TESTI ' BEFOP"C^A'ur'IvG OF OCCUPANCY FLOOD 7C ��E COMPLY V'31H CHAPTER 148 RETAIN STORM WATER r'IUMOFF FLOOD DA;11GE PREVENTION PURSUANT TO CHAPTER 236 _ eDUIhDLD ° C; N7I GDE OF THE TOWN CODE.bld architecture, dpc. ELECTRICAL 31 W Main St. s205 INSPECTION! REQUIRED Patchogue, New York 11772 (631) 580-2100 MATERIAL SYMBOL LEGEND ARCHITECTURAL ABBREVIATIONS: LEGEND: A F M S PARTITION/WALL TO BE REMOVEDFD FLOOR DRAIN MAN MANUAL ACT ACOUSTICAL CEILING TILE S SINK EARTH ADDL ADDITIONAL FDN FOUNDATION MATL MATERIAL SCH SCHEDULE EXISTING PARTITION/WALL TO REMAIN ADJ ADJUST/ADJACENT FE FIRE EXTINGUISHER MAX MAXIMUM SCWD SOLID CORE WOOD ADMIN ADMINISTRATION FIN FINISH MC MEDICINE CABINET SD SHOWER DRAIN AFF ABOVE FINISH FLOOR FIXT FIXTURE MCJ MASONRY CONTROL JOINT S/D SMOKE DAMPER NEW 1 HR RATED PARTITION FLASH FLASHING MD METAL DECK SDISP SOAP DISPENSER AHU AIR HANDLING UNIT FLEX FLEXIBLE MECH MECHANICAL SE SOUTHEAST ALT ALTERNATE MEMB MEMBRANE NEW NON-RATED PARTITION ALUM ALUMINUM FLUOR FLUORESCENT MTL METAL SECT SECTION �000°aoo�o°O$ FRMG FRAMING MEZZ MEZZANINE SF SQUARE SECRETARY STOW FILL AL ALUMINUM SQUARE FOOT 0 o ANUN ANNUNCIATOR FT FOOT/FEET MFR MANUFACTURER SH SHOWER NEW 2HR RATED PARTITION APPROX APPROXIMATE FTG FOOTING MH MANHOLE SHT SHEET CsYP BOARD ARCH ARCHITECTURAL FURR FURRING MIN MINIMUM SHTG SHEATHING AUTO AUTOMATIC FUT FUTURE MIR MIRROR SIM SIMILAR ® MO MISCELLANEOUS SURF MTD SURFACE MOUNTED WOOD�MI� � B C' MO MASONRY OPENING SPEC SPECIFICATIONS BD BOARD GA GAUGE MONO MONOLITHIC SQ SQUARE P## P## WALL TYPE TAG BLDG BUILDING GAL GALLONS MTD MOUNTED SQ YD SQUARE YARD SS STAINLESS STEEL ® BLKG BLOCKING GALV GALVANIZED MULL swim BM ST STREET BM BEAM GC GENERAL CONTRACTOR STD KEY PLAN BLDG. 'A' ISSUED FOR PERMIT 11-18-2016 STANDARD ISSUED FOR PRICING 07-08-2016 BO BOTTOM OF GL GLASS N STL STEEL ® BOT BOTTOM NA NOT APPLICABLE WOOD 5„�M �� BR BRICK GR GRADE NE NORTHEAST STOR STORAGE ( BRG BEARING GYP.BD. GYPSUM BOARD NIC NOT IN CONTRACT STRUCT STRUCTURAL O EXISTING DOOR TO BE REMOVED GYP GYPSUM SUPV SUPERVISOR REVISION: DATE: ® f C NO NUMBER SUSP SUSPENDED H NOM NOMINAL S SWITCH EXISTING DOOR TO REMAIN CAB CABINET H HEIGHT NRC NOISE REDUCTION Sy,/ SOUTHWEST LNG TITLE: CA NTL CANTILEVER HD HEAD NT COEFFICIENT SWD SOFTWOOD SITE PLAN, DRAWING LIST BATT INSIIt.ATION CAP CAPACITY HDCP HANDICAP CEM CEMENT NTS NOT TO SCALE HDR HEADER NW NORTHWEST r ABBREVIATIONS E� CJ CONTROL JOINT HDW HARDWARE B NEW DOOR CL CENTER LINE TAN TANGENT RIGID INSULATION CLG CEILING HM HOLLOW METAL O TBD TACKBOARD ROOM NAME 1 CMU CONCRETE MASONRY UNIT HORZ HORIZONTAL OC ON CENTER TEL TELEPHONE ® ROOM NAME 1 ROOM TAG COL COLUMN HT HEIGHT OD OUTSIDE DIAMETER TEMP TEMPERATURE CA140ET fpp CONC CONCRETE HTR HEATER OFF OFFICE T&G TONGUE&GROOVE XXXXX SF CONE CONFERENCE HVAC HEATING,VENTILATION, OH OVERHEAD THRES TOILETE THRESHOLD TOIL CONN CONNECT/-ED/-ION AIR CONDITIONING OPER OPERATORSCALE: AS NOTED BLOHW HOT WATER OPNG OPENING T.O. TOP OF CONCftTM CK SECTION NO. CONT CONTINUOS OPP OPPOSITE TOW TOP OF WALL DRAWN BY: CONST CONSTRUCTION PVMT PAVEMENT TOS TOP OF SLAB/STEEL CJG 2 SECTION MARK CONTR CONTRACT PWR POWER TRAN TRANSFORMER A4.3 COORD COORDINATE ID INSIDE DIAMETER® TV TELEVISION It is a violation of the Education Law of the State of New York for IMICK SHEET NO. CORR' CORRIDOR IN INCH P-0 TYP TYPICALBLDG �A, SOUND any person, unless he is acting under the direction of a licensed CPT CARPET INSUL INSULATION PART PARTITION (, Architect to alter an item on this drawingand/or in this INT INTERIOR PED PEDESTAL ll IS� D specification in any ay. If any such item is altered, the altering ELEVATION NO NG Architect shall affix to the item his seal and the notation "altered G:fiGf� AL6M"tINM 3 . CT CERAMIC TILE CTR CENTER PL PLATE U URINAL UNO UNLESS NOTED LO q3,4 ELEVATION MARK i PL PROPERTY LINE b ' followed b his signature and the date of such alteration SHEET NO. CUFT CUBIC FEET JAN JANITOR OTHERWISE Y Y PLAM PLASTIC LAMINATE UTIL UTILITY ?....... .._ together with a specific description of the alteration. ® CUH CABINET UNIT HEATER JB JUNCTION BOX PLBG PLUMBING STI. r-1 CW COLD WATER JST JOIST PLYWD PLYWOOD V �FtED /��jC DETAIL NO. D JT JOINT PNL PANEL VENT VENTILATION t�� PR PAIR VERT VERTICAL ��� PN"DeR BApq( J, DETAIL MARK DEMO DEMOLITIONPRESSURE SHEET NO. DEPT DEPARTMENT K PR PRESS PRIMARY VEST VESTIBULE 4u DET DETAIL KO KNOCK OUT PROJ PROJECTION w-x-Y-z NORTH ROAD 2� M MATERIAL TAG DF DRINKING FOUNTAIN W WIDTH/WIDE PTR PRINTER WALL MOUNTED EXIT SIGN DIA DIAMETER LVR LOUVER PVC POLYVINYL CHLORIDE W WIDE FLANGE DIAG DIAGONAL ®-I L LENGTH W/ WITH ' L/LA C WATER {� V LAVATORY R CEILING MOUNTED EXIT SIGN LBS POUND WCLOSET DIFF DIFFUSER D WOOD N� DIM DIMENSION R RISER / RADIUS WDW WINDOW '9 �-, �rF�k�—�.✓ Q� DISP DISPENSER LF LINEAL FOOT RA RETURN AIR WHTR WATER HEATER �,(� 020193 �0 5.lv�.E. SURFACE MOUNTED FIRE EXTINGUISHER LIN LINEAR RAD RADIATION ® DIV DIVISION W/O WITHOUT DN DOWN LKR LOCKER RCP REFLECTED CEILING PLAN WT WEIGHT RECESS MOUNTED FIRE EXTINGUISHER CABINET 14 DWG DRAWING LLH LONG LEG HORIZONTAL RD RECESSED DRAIN F NE DWLS DOWELS LLV LONG LEG VERTICAL E LOC LOCATION RECEPT RECEPTACLE RECEIPT RECEPTION COPYRIGHT © 2 O EA EACH OR LOCATE REF REFERENCE EC ELECTRIC CABINET LT LIGHT REF REFRIGERATOR REINF REINFORCE DWG. NO. EF EXHAUST FAN LTG LIGHTING REQD REQUIRED EL ELEVATION RES RESISTANT ELEC ELECTRICAL RET RETAINING ELEV ELEVATION REV REVERSE/REVISE ENTR ENTRANCE RM ROOM EQ EQUAL RO ROUGH OPENING EQUIP EQUIPMENT RS ROUGH SLAB EXIST EXISTING RV ROOF VENT EXP EXPANSION EXT EXTERIOR CVR EWC ELECTRIC WATER COOLER 16-1022 SOUND VIEW INN RENOVATION V GREENPORT, N.Y. SOUND VIEW 71 ®CP r �P INN UNIT#19 UNIT#2a UNIT#21 _ UNIT#22 UNIT#23 UNIT#24 UNIT#25 uNFC#ab; 0 _= RENOVATION ,� it GREENPORT, N.Y. 11944 L CFO)Lj AREA OF WORK b I d architecture, d pc CONSTRUCTION FLOOR PLAN: BUILDING 'A31 West Main Street,Suite 205 Patchogue, NY 11772 1 KEY PLAN TEL:631 580 2100 9760 -Al. SCAL N.TSwww.baidassano.com DESIGNER: PROVIDE NEW BATT INSULATION Studio Tack & GYPSUM BOARD AT EXTERIOR �: � Bro Plymouth street WALL. PAINT. rooklyn,NY 11201 NEW DOOR & . HARDWARE. REPLACE IN EXISTING OPENING NEW FLOOR TILE PROVIDE SADDLE AT NEW WATER CLOSET TO ��� REPLACE EXISTING (NO NEW VERTICAL WALL DOOR THRESHOLD � CHANGE TO ROUGH SCONCE. NEW CARBON PLUMBING) CENTERLINE OF MONOXIDE DETECTOR TO FIXTURE MOUNTED ________ __= BE HARDWIRED TO EXISTING TOILET NEW SINK FIXTURE TO TO WALL @ 5-0" EXISTING ELECTRIC & FIRE C� 1 FIXTURE TO BEALARM PANEL REPLACE EXISTING A.F.F. /U (NOCHANGE TO REPLACE EXISTING REMOVED [" EXISTING SINK FIXTURE AND _. _.! _ ROUGH PLUMBING) FLUSH MOUNTED--- EXHAUST FAN / BTHRM I • VANITY TO BE REMOVED FIXTURE AT i • BTHRM 4"SHOWER CURB EXISTING PENDANT — —— - ; - - - NEW SHOWER HEAD AND LOCATION, V.I.F. / \ _ NEW VANITY LIGHT \/ EXISTING SHOWER TO ___ TRIM AT EXISTING HEAD \ - CENTERED ABOVE EXISTING �:-- BE REMOVED LOCATION (NO CHANGE SINK TO ROUGH PLUMBING) i EXISTING BUILT-IN —-� MILLWORK TO BE fl S \ 1 -- -;- --- -- -- ---------. .._------------------ I REFRIGERATOR \ \ REMOVE EXISTING REMOVED L_ — J BELOW \ \\ NEW VERTICAL WALL FLOORING AND — SCONCE. CENTERLINE OF BASE — NEW ---- METAL BACKED ROSE NEW OUTLETS FIXTURE MOUNTED TO HEADBOARD TINTED MIRROR MILLWORK MOUNTED TO WALL INSTALLED IN � WALL @ 6-6"A.F.F. HEADBOARD (ABOVE MIRROR) REMOVE BY OTHERS -_ EXISTING BUILT-IN MILLWORK 1 l FLOORING MILLWORK AND BASE NEW PAINT NEW SWING ARM EXISTING SMOKE THROUGHOUT LAMP CENTERLINE DETECTOR NEW CLOS ---- ---, TO REMAIN MILLWORK BY NEW RUBBER OF FIXTURE i .. . .. MOUNTEDEr OTHERS TO FLOORING WALL @4''-0" A.F.F. NEW CEDAR 3 TRIM BASE BOARD NEW DOOR. REPLACE, IN EXISTING \ OPENING. WEATHERSTRIP AS NOTE: PATCH AND REPAIR NOTE: REQUIRED NOTE: ALL OUTLETS, DATA ALL SURFACE FOR NEW 1. ALL WALL AND CEILING FINISHES TO BE AND SWITCHES ARE EXISTING FINISHES MINIMUM CLASS C RATING TO REMAIN, U.O.N. 2. ALL FLOOR FINISHES TO BE MINIMUM CLASS II RATING 3. COORDINATE SPECIFICATIONS OF ALL FINISH MATERIALS WITH FINISH SCHEDULE BY STUDIOTACK 4. MODIFY ROUGH-IN PLUMBING AS REQUIRED FOR NEW FIXTURES, TYP. r2_'% DEMOLITION FLOOR PLAN: BLDG. 'A': MODEL UNIT #25 3 CONSTRUCTION FLOOR PLAN: BLDG. 'A': MODEL UNIT #25 4 RCP/POWER/DATA FLOOR PLAN: BLDG. 'A': MODEL UNIT #25 SCALE: 1/4"= 1'-0" -Al. SCALE. 1/4"— 1 -0 BLDG. 'A' ISSUED FOR PERMIT 11-18-2016 ISSUED FOR PRICING 07-08-2016 REVISION: DATE: DRAWING TITLE: CONSTRUCTION PLAN: BUILDING 'A' FLOOR PLAN SCALE: AS NOTED DRAWN BY: CJG It is a violation of the Education Law of the State of New York for any person, unless he is acting under the direction of a licensed Architect to alter any item on this drawing and/or in this specification in any way. If any such item is altered, the altering Architect shall affix to the item his seal and the notation "altered by" followed by his signature and the date of such alteration together with a speLiLiiiiiiii of the alteration. �,\�F ED A, G� BOER BApq� y/J, 020193 FNE : COPYRIGHT © 2010 DWG. NO. A�Al ■ 16-1022 SOUND VIEW INN RENOVATION GREENPORT, N.Y. SOUND VIEW INN 0 0 0or5:71 0 a 0 0 RENOVATION GREENPORT, N.Y. 11944 IL �� 774__ Lj Lj L—i :�7 Lj AREA OF WORK bld architecture, dpc CONSTRUCTION FLOOR PLAN: BUILDING 'A' UNIT#18 '� 31 West Main Street,Suite 205 1 KEY PLAN 'LA ` Patchogue.NY 11772 � TEL 631 580 2100 FAX:631 580 9760 www.baldassano.com f i \ DESIGNER: �t Studio Tack NEW VERTICAL WALL 197 Plymouth street SCONCE. CENTERLINE Brooklyn,NY 11201 OF FIXTURE MOUNTED TO WALL @ 5-0"A.F.F. ALL OUTLETS NEW OUT-SWING DOOR & FRAME REPLACE IN EXISTING _ ILLUSTRATED ARE \ EXISTING DOOR OPENING. EXISTING AND ARE TO & FRAME TO BE REMAIN, TYP. \\ FLUSH MOUNTED FIXTURE REMOVED. BUILT-IN MILLWORK NEW VERTICAL WALL \ AT EXISTING PENDANT LOCATION, V.I.F. REFRIGERATOR SCONCE. CENTERLINE BELOWOF FIXTURE MOUNTED i NEW CARBON METAL BACKED ROSE TINTED - __ _ __. _ __ _. - - -- _______ --------- -- TO WALL @ 6-6" A.F.F. --,,_ �_u -� �_ / MONOXIDE DETECTOR TO —__ — / EXISTING SINK- / MIRROR MOUNTED TO WALL c-- ----� (ABOVE MIRROR) BE HARDWIRED TO FIXTURE AND __ _ REPLACE EXISTING / ALARM PANEL� EXISTING ELECTRIC & FIRE VANITY TO BE /� REMOVE EXISTING NEW SINK FIXTURE TO EXHAUST FAN ,., REMOVED I FLOORING AND REPLACE EXISTING (NO BASE CHANGE TO ROUGH ) / EXISTING TOILET----------,, PLUMBING) / FIXTURE TO BE REMOVED -ten NEW WATER CLOSET TO \ �- - ( EXISTING SMOKE 1U REPLACE EXISTING (NO \ DETECTOR CHANGE TO ROUGH \�� i TO REMAIN PLUMBING) EXISTING BATHTUB TO I EXISTING — DOORS TO BE NEW CEDAR BE REMOVED :u:.) T �\ ji TRIM BASE iI�N REMOVED. / EXISTING 4"SHOWER CURB '', BOARD !' 3 FRAME TO \ PROVIDE NEW BATT NEW FLOOR J NEW RUBBE INSULATION & TILE FLOORING GYPSUM BOARD AT NEW PAINT EXTERIOR WALL. THROUGHOUT PAINT. PROVIDE SADDLE NEW DOOR & AT DOOR HARDWARE REPLACE THRESHOLD IN EXISTING NOTE: OPENING. 1. ALL WALL AND CEILING FINISHES TO BE MINIMUM CLASS C RATING 2. ALL FLOOR FINISHES TO BE MINIMUM CLASS II RATING 3. COORDINATE SPECIFICATIONS OF ALL FINISH MATERIALS WITH FINISH SCHEDULE BY STUDIOTACK 4. MODIFY ROUGH-IN PLUMBING AS REQUIRED FOR NEW FIXTURES, TYP. 2 DEMOLITION FLOOR PLAN: BLDG. 'A': MODEL UNIT # 18 3 CONSTRUCTION FLOOR PLAN: BLDG. 'A': MODEL UNIT #18 r4 *NN RCP/POWER/DATA FLOOR PLAN: BLDG. 'A': MODEL UNIT # 18 -A1.1 SCALE: 1/4"= 1'-0" -A1.1 SCALE: 1/4"= 1'4" BLDG. 'A' ISSUED FOR PERMIT 11-18-2016 ISSUED FOR PRICING 07-08-2016 REVISION: DATE: DRAWING TITLE: CONSTRUCTION PLAN: BUILDING 'A' FLOOR PLAN SCALE: AS NOTED DRAWN BY: CSG It is a violation of the Education Low of the State of New York for any person, unless he is acting under the direction of a licensed Architect to alter any item on this drawing and/or in this specification in any way. If any such item is altered, the altering Architect shall affix to the item his seal and the notation "altered by" followed by his signature and the date of such alteration together with a specific description of the alteration. ED A/ZL,y G �QER BADl Q � a * �a „ (nom "'_''tP��3 '"•J—rJ 1. 020193` vV COPYRIG c 201 DWG. NO. AmAl ■ 1 16-1022 SOUND VIEW INN RENOVATION GREENPORT, N.Y. SOUND VIEW INN ` RENOVATION GREENPORT, N.Y. 11944 E, JUo - o 174= L bld architecture, dpc 31 West Main Street, Suite 205 Patchogue, NY 11772 AREA OF WORK CONSTRUCTION FLOOR PLAN: BUILDING 'A' UNIT#17 EL:631 580 2100 „� "--� . 1 580 9760 www.baldassano.com KEY PLAN @. SCALE: N.T.S. DESIGNER: Studio Tack 197 Plymouth street Brooklyn, NY 11201 R . NEW DOOR & I I I I I I I HARDWARE. REPLACE IN EXISTING OPENING I I I I I I I NEW CARBON REMOVE EXISTING INTERIOR PROVIDE SADDL MONOXIDE DETECTOR TO GYPSUM BOARD AT AT DOOR PROVIDE NEW BATT BE HARDWIRED TO BATHROOM EXTERIOR WALL THRESHOLD INSULATION & GYPSUM EXISTING ELECTRIC & FIRE BOARD AT EXTERIOR ALARM PANEL IM WALL. PAINT. `�. iLV-�-ii 4"SHOWER CURB _ . EXISTING DOORS TO N t ` EXISTINGi� BE REMOVED. ,>' - --------------------- -_ __ NEW FLOOR TILE f REMAIN ii BE REMOVED EXISTING TOILET FIXTURE & ^� - / \ \ V11 ti (��1 ---- - - i GRAB BARS TO BE REMOVED II �% �I� ll� i _ \ NEW SINK FIXTURE TO �[__] } REPLACE EXISTING EXISTING DOOR & ® - - ---- REPLACE EXISTING (NO CHAINGE TO ROUGH '� EXHAUST FAN FRAME TO BE NEW WATER CLOSET TO PLUMBING) \� REMOVED. EXISTING SINK REPLACE EXISTING (NO NEW VERTICAL WALL SCONCE. FIXTURE AND CHANGE TO ROUGH VANITY TO BE PLUMBING) \��\ CENTERLINE OF FIXTURE �REMOVE EXISTING--- REMOVED \ MOUNTED TO WALL C 6-6" FLOORING AND METAL BACKED ROSE TINTED A.F.F. (ABOVE MIRROR) MIRROR MOUNTED TO WALL BASE FLUSH MOUNTED FIXTURE AT REFRIGERATOR EXISTING PENDANT BELOW i LOCATION, V.I.F. t BUILT-IN MILLWORK f EXISTING SMOKE DETECTOR { TO REMAIN NEW RUBBER ALL OUTLETS FLOORING ILLUSTRATED ARE EXISTING AND ARE TO NEW CEDAR REMAIN, TYP. TRIM BASE BOARD NEW PAINT THROUGHOUT NOTE: 1. ALL WALL AND CEILING FINISHES TO BE MINIMUM CLASS C RATING 2. ALL FLOOR FINISHES TO BE MINIMUM CLASS II RATING 3. COORDINATE SPECIFICATIONS OF ALL FINISH MATERIALS WITH FINISH SCHEDULE BY STUDIOTACK 4. MODIFY ROUGH-IN PLUMBING AS REQUIRED FOR NEW FIXTURES, TYP. 2 DEMOLITION FLOOR PLAN: BLDG. 'A': MODEL UNIT #17 3 CONSTRUCTION FLOOR PLAN: BLDG. 'A': MODEL UNIT #174 RCP / POWER / DATA PLAN: BLDG. 'A': MODEL UNIT #17 SCALE: 1/4"= 1'-0" -Al. SCALE: 1/4"= 1'-0" -A1. SCALE: 1/4"= 1'-0" BLDG. 'A' ISSUED FOR PERMIT 11-18-2016 ISSUED FOR PRICING 07-08-2016 REVISION: DATE: DRAWING TITLE: CONSTRUCTION PLAN: BUILDING 'A' FLOOR PLAN SCALE: AS NOTED DRAWN BY: CSG It is a violation of the Education Law of the State of New York for any person, unless he is acting under the direction of a licensed Architect to alter any item on this drawing and/or in this specification in any way. If any such item is altered, the altering Architect shall affix to the item his seal and the notation "altered by" followed by his signature and the dote of such alteration together with a specific description of the alteration. ED A Ns ER ER B.ADq Qy •-1 N0 �- 9T� 020193 COPYRIGH c 2010��- DWG. NO. AmAl ■ 2 16-1022 SOUND VIEW INN RENOVATION GREENPORT, N.Y. SOUND VIEW FTM INN cv 5]P;> RENOVATION 7. . GREENPORT, N.Y. 11944 UNIF'#1.,<. 0 UNIF# C1NIT'#3 UNIT#4 I1NIF 0S UNIT#l� UNIT#7 UNIT#8 UNIT.#9 . UNIT#10 UNIT;#11 llNIF#12 UNIT#1 UNiF#15 Ut IIF#k i 6. 0 0 0 0 jKT 6LIZ L CU bld architecture, dpc 31 West Main Street,Suite 205 Patchogue, NY 11772 AREA OF WORK TEL:631 580 2100 f' FAX:631 580 9760 I DESIGNER: t v'` $ www.baidassaiio.com CONSTRUCTION FLOOR PLAN: BUILDING ' A �� , 1 JKEY PLAN i ��<:,, -Al. SCALE: N.T.S. Studio Tack t]� 197 Plymouth street NEW DOOR & 'Jl Brooklyn, NY 11201 HARDWARE. REPLACE PROVIDE NEW BATT I I I I IN EXISTING OPENING INSULATION & GYPSUM PROVIDE SADDLE BOARD AT EXTERIOR WALL. PAINT. REMOVE EXISTING INTERIOR AT DOOR NEW VERTIC GYPSUM BOARD AT THRESHOLD NEW DOOR WALL SCONCE. BATHROOM EXTERIOR - WALL _ NEW WATER CLOSET TO REPLACE EXISTING REPLACE EXISTING ��_, �f i't i EXHAUST FAN EXISTING DOORS TO �� � t t (( ) .It t t NO CHANGE TO BE REMOVED. �� EXISTING TOILET � ( t EXISTING FRAME TO r---� FIXTURE TO BE - - _ _ - ROUGH PLUMBING) REMAIN i : REMOVED NEW SINK FIXTURE TO EXISTING SINK FIXTURE --- REPLACE EXISTING (NO i AND VANITY TO BE _.__.. . CHANGE TO ROUGH / REMOVED I PLUMBING) i EXISTING BATHTUB -- 4"SHOWER CURB FIXTURE TO BE ---------� i REMOVED - NEW TILE FLOORNEW VER WALL EXISTING DOOR & ` S \ SCO CETICAL CENTERL NE OF FRAME TO BE . I METAL BACKED ROSE `\REMOVED. ------------------------------------------------------------ = --- ---- ------ - TINTED MIRROR \�� FIXTURE MOUNTED TO WALL MOUNTED TO WALL @ 6-6"A.F.F. (ABOVE ! - __________ REFRIGERATOR BELOW � = MIRROR) REMOVE EXISTING - ------- --- - --------- �� FLUSH MOUNTED FIXTURE AT FLOORING AND NEW PAI EXISTING PENDANT BASE THROUGHOUT b BUILT-IN MILLWORK i b LOCATION, V.I.F. NEW CED NEW RUBBER t TRIM BASE FLOORING ALL OUTLETS ILLUSTRATED BOARD ARE EXISTING AND ARE TO i REMAIN, TYP. NOTE: 3 1. ALL WALL AND CEILING FINISHES TO BE -- - MINIMUM CLASS C RATING 2. ALL FLOOR FINISHES TO BE MINIMUM CLASS EXISTING SMOKE II RATING DETECTOR TO REMAIN 3. COORDINATE SPECIFICATIONS OF ALL NEW CARBON FINISH MATERIALS WITH FINISH SCHEDULE BY MONOXIDE DETECTOR TO STUDIOTACK BE HARDWIRED TO EXISTING ELECTRIC & FIRE 4. MODIFY ROUGH-IN PLUMBING AS ALARM PANEL REQUIRED FOR NEW FIXTURES, TYP. r2-'N\ DEMOLITION FLOOR PLAN: BLDG. W: MODEL UNITS #1 - 143 CONSTRUCTION FLOOR PLAN: BLDG. W.- MODEL UNITS # 1 - 14 4 RCP / POWER / DATA PLAN: BLDG. 'A': MODEL UNITS # 1 - 14 A-A1.3 SCALE: 1/4"= 1'Z' A-A1. SCALE: 1/4"= 1'-0" -Al. SCALE: 1/4"= 1'-01, 5 3 NEW VERTIC BLDG. W ISSUED FOR PERMIT 11-18-2016 WALL SCONCE. ISSUED FOR PRICING 07-08-2016 REVISION: DATE: i DRAWING TITLE: ° REPLACE EXISTING EXHAUST FAN CONSTRUCTION PLAN: BUILDING 'A' - FLOOR PLAN SCALE: AS NOTED t DRAWN BY: CSG ,CO'2 S 3 NEW VERTICAL WALL It is a violation of the Education Low of the State of New York for on person, unless he is actin � SCONCE. CENTERLINE OF y p g under the direction of a licensed Architect to alter any item on this drawing and/or in this FIXTURE MOUNTED TO WALL specification in any way. If any such item is altered, the altering @ 6-6" A.F.F. (ABOVE Architect shall affix to the item his seal and the notation "altered t MIRROR by" followed by his signature and the date of such alteration - ) together with a specific description of the alteration. f FLUSH MOUNTED FIXTURE AT EXISTING PENDANT ,�;�pED qR b LOCATION, V.I.F. G�5 oER aqo C'Si { ALL OUTLETS ILLUSTRATED ' 3 ARE EXISTING AND ARE TO -- REMAIN, TYP. 9�� 020193 Q� EXISTING SMOKE — DETECTOR TO REMAIN COPYRIGH c 2010"%A NEW CARBON DWG. NO. MONOXIDE DETECTOR TO BE HARDWIRED TO EXISTING ELECTRIC & FIRE ALARM PANEL a 5 RCP / POWER / DATA PLAN: BLDG. 'A': MODEL UNITS # 15 & 16 AAl m3 SCALE: 1/4"= l'-0" 16-1022 SOUND VIEW INN RENOVATION GREENPORT, N.Y.