Loading...
HomeMy WebLinkAbout38079-Z Town of Southold rA o 5/23/2017 P.O.Box 1179 0 o ! 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38965 Date: 5/23/2017 THIS CERTIFIES that the building ELECTRICAL Location of Property: 1635 Smith Rd, Peconic SCTM#: 473889 Sec/Block/Lot: 98.-4-17 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/7/2013 pursuant to which Building Permit No. 38079 dated 6/7/2013 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator with 100a underground electric service as applied for. The certificate is issued to Dittman,Richard of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 38079 5/23/2017 PLUMBERS CERTIFICATION DATED uthorized Signature TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy��al Sao SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 38079 Date: 6/7/2013 Permission is hereby granted to: Dittman, Richard 1635 Smith Rd Peconic, NY 11958 To: Electrical Underground Service At premises located at: 1635 Smith Rd, Peconic SCTM # 473889 Sec/Block/Lot#98.-4-17 Pursuant to application dated 6/7/2013 and approved by the Building Inspector. To expire on 12/7/2014. Fees: ELECTRIC $85.00 Total: $85.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: _erwo!! J ZG '00"/ c e House No. Street Hamlet Owner or Owners of Property: /6 Suffolk County Tax Map No 1000, Section Block Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ Applicant Signature ®F soUry®� Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 ® roperAchert(C7town.southoId.ny.us Southold,NY 11971-0959 a ®lyC®UNT`d,�� BU LDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Dittman Address: 1635 Smith Road City: Peconic St: New York Zip: 11958 Budding Permit#: 38079 Section. 98 Block: 4 Lot: 17 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Ice Electric License No: 4586-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph 100A Heat Duplec Recpt Ceding Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 100A A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect 100A I Switches Twist Lock Exit Fixtures TVSS Other Equipment: 100A UNDERGROUND SERVICE Notes: 10KW Standby Generator with Auto Transfer Switch. Inspector Signature: Date: May 16, 2017 0-Cert Electrical Compliance Form.xls p'F SO�l�ol � ` I Town Hall Annex Telephone(631)765-1802 54375 Main Road y • O flax(63765-�5Q WP.O.Box 1179 G rOQer.rIC7'rt0O .nV US Southold,NY 11971-0959 'r BUILDIN • G DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: — /3 Company Name: i Name: License No.: Address: Phone No.: JOBSITE INFORMATION: (*Indicates required information) i *Name: ,� ✓� ���ff� i �h ' *Address: *Cross Street: *Phone No.. -- Permit No.: Tax-Map District: 4000 Section: �� Block: Lot:– "7 — *BRIEF DESCRIPTION OF WORK(Please Print Clearly) 10 (Please Circle All That Apply) Is job ready for inspection: ES NO Rough In Fina! *Do you need a Temp Certificate: ES/ NO Temp InformationnPhase ) f *Service Size: 3Phase 0 150 200 300 350 . 400 Other *New Service: Re-connect nderground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for inspection Form �S TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY.11971 4 sets of Building Plans _ TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. Check %1D0 --- l7 = Ja. � Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined- ,20 Single&Separate Storm-Water Assessment Form Contact: Approved ,20 Mail to: Disapproved a/c Phone: Expiration ,20 Building Inspector D [ECEIVE PLICATION FOR BUILDING PERMIT , MAY 2 3 2017 INSTRUCTIONS Date 20 a. This a Iicatio be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of planse. Fee according to schedule. b. le i IN of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. — c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land owhich proposey work will be do h C' House Number - Street Hamlet County Tax Map No. 1000 Section Block Lot - l Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupan y of proposeo construction: a. Existing use and occupancy RA,�M t (� b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories �j1 rad =:+ •� , 1# "' 8. Dimensions of entire new construction: Front Rear : A S r a . bptli;; �-,a•--: Height Number of Stories %J 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner '{.4' .>:L.r l.b'..r 'f a..• ,S�Tt, S .,hT 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premises Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 015 a Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NOS * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contract ,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of 20 Notary Public Signature of Applicant a1635 Smfth Rd 1 ti Google Earth ' 11 • • Earth 11 GENERAC GUARDIANO SERIES Residential Standby Generators Air-Cooled Gas Engine • Tm � Electrical Standby P0�[ Rating oa|Teohno|ogy —' � --�g Models GO07O2Q-O.G00703O-0 (Aluminum-Bisque) 0kVV60Hz N» Two Line LCD Multilingual Digital Models G007032-0,G007033'0 (Aluminum Bisque) '11 kVV8O Hz Evolution" OOOt[O||Sr/EO�|i3h/Gp8niSh/ � ` y�ode| GOO7031-0V�unnmunn- Bioque) 11kVV60Hz F[ROCh/PO�ugU8Se> ` ' • Two Transfer Switch Options Available: 1OOAmp 1OCiFCuitSwitch o[ 2OOAmp Service Rated Switch. See Page 4for Details, N0 Electronic GovernorZt N» System Status &Maintenance Interval LED Indicators Nw Sound Attenuated EnclosureENERA N» Flexible Fuel Line Connectortj • Oinaot-To'DirtComposite Mounting Pad • Natural Gas orLPGas Operation � ��� • 5Year Limited Warranty IUSTM o� Capability be installed 18" �457 [Dnl) m«mm« ~�a�mmm"�mmomm�mm�/mv��o�mmn ^ ` ` limited circuit U"~va�ommmm"mx°t°==are"`=m.=. of building* the USA only ocated away from doors, and fresh air Intakes,and unless omonwoodirected»vlocal codes. FEATURES O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are atthe heart ofGenomc'o D 80UD-STATE,FREQUENCY COMPENSATED VOLTAGE REGULATION: success in providing the most reliable generators possible.Generac's G-Force engine This otato-of-th**rtpower maximizing regulation system mstandard on lineup offers added peace ofmind and reliability for when you need nthe most.The all Gonommmodels.|tprovides optimized FAST RESPONSE tochanging G-Force norino engines are purpose built and designed to handle the rigors of load conditions and MAXIMUM MOTOR STARTING CAPABILITY by extended run times inhigh temperatures and extreme operating conditions. electronically torque-matching the surge loads to the engine. Digital voltage regulation��1%. O TRUE POWER­ ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Gnnomc'oextensive dealer form produce less than S%Total Harmonic Distortion for utility quality power.This allows network provides parts and service know-how for the entire unit,from the confident operation of sensitive electronic equipment and micro-chip based appliances, engine tothe smallest electronic component. such asvariable speed WAC systems D TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENE�C POWER SYSTEMS. One reason for this � PROTOTYPE TESTED � NE���81��EVALV&T � '0N oo�idoo�ioth�the GENERACpmdu*|moincludes its own tmno�r / 8Y8TE�T08&|ONALT[0TEO / �OTOH8TARJ|NG8@|UTY systems and controls for total system compatibility um �� � �� [ �� � �� Y� � y� � ����Y� Z PROMISE h GENERAC® 9/11 kW features and benefits Engine i, • GeneracG-Forcedesign Maxim izes engine"breathing"for increased fuel efficiency Plateau honed cylinderwalls and plasma moly rings helps the engine inn cooler,reducing oil consumption resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life.Now featur- ing up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown. Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator h Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 3R p' Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple,low-cost installation Evolution" Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history,maintenance and events up to 50 occurrences • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 12 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load,setpomt approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise �I Operates engine to prevent oil seal drying and damage between power outages by running the generatorfor 12 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel !' costs to the owner r • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generatorfrom overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph.Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items Electrostat- ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18"away from a building. Installation System • 1 ft(305 mm)flexible fuel,line connector Absorbs any generator vibration when connected to rigid pipe. • Direct-to-dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. • Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine,prolonging engine life. e i GENERACO 9/11 kW specifications Generator -Model 0007029-0,G007030-0(9 kM G007031-0,G007032-0,G007033-0(11 kW) Iiated Maximum Continuous at Rated Maximum Continuous Power Capacity(NG) 8,000 Watts* 10,000 Watts* e,�V*Volta t-"e" ,Q g 0 Rated Maximum Continuous Load Current-240 Volts(LP/NG) 37 5/33 3 µ 45.8/417 Notal HarmonicI�tortlorl -� Less than 5 than Main Line Circuit Breaker 40 Amp �O Amp Phase 'Number of Rotor Poles 2 2 rRifFrequency0 H eAb Power Factor 10 10 'Battery Aeqirement(�not[n—cluded 7 MIT 546106 A-,lvlmlrquT orCCA Minim MR Unit Weight(Ib/kg) 340/154 348/158 Lpjaeqsi cEs(L x W x H)irl/mm Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load** 66 63 Engine Type of Engine GENERAL G-Force 400 Series GENERAC G-Force 500 Series Displacement 426 cc 530 cc -CyhW-dei BloBlock­ - 7Afiii. n W60lro "�T w/, Cast f-I Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve 71 o .. , ........ Governor System Electronic Electronic u f Starter 12 Vdc 12 Vdc 7 7, Oil Capacity Including Fi pprox 1 V .0 L ql�Q L ......I _q Operating rpm 3,600 3,600 ; V 7 7,'Fu-�el Consumption Natural Gas Itathr(m3/hr) A/2 Load 90(2.55)� 1 C17(3 03)"' .,Full Load, 120 (3 4) '(450 Liquid,Propane fV/hr(gal/hr)[1/hr] ) 1/21­6ad '31 6(87),[3 29]�-' 44,4(l 22)[4.62] 1.6', Full Load,, 515(1.37)• 21- (f,97 [7' Note Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3 5-7"water column(7-13 mm mercury)for natural gas,10-12"water column(19-22 mm mercury) for LP gas For Btu content,multiply f0/hr x 2500(LP)or 0/hr x 1000(NG) for Megaloule content,multiply ma/hrx 9315 x 37 26(NG) Controls _(LP)or m3/ hr Plain Text Multilingual LCD Display Simple user interface for ease of operation -Au- -- --- tornatic Start onUtility re,7,.day,ex exerciser', Manual Start with starter control,unit stays on If utility fails,transfer to load takes place --—'a,Control'' - F, Stop's unit, ower is removeand operate P -er.si- FieidY;to Run/Maintenance Messages Standard 7, 7", ---------'Standard -`77 n­f,,��RKqLii(s Rd(c�fl�7 Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) i-C,likVditage Loss/Return'to Lltil FF6ERIJ-17f Vfi�0'�1 6 V Future Setce�ple Exerciser/Exercise Set Error Warning Standard 7 Events a.-cfi,l kunA069a,in'tehan,ce Lags _ Engine Start Sequence Cyclic cranking:Engine cranks a maximum of five times at factory set intervals and durations Starter pmotneq Starter Lock-out 'S Smart Battery Charger Standard F-7 7- F -7- n-" -Wairo'n-f 77.-'T-, `7 Low Battery/Battery Problem ProtectionandBattery Condition Indication Standard rk l Voltage ..1aQ9',rotec ion, Standard gblailon with OverandUnderVol _,,tan d Under-Frequericy/Overload/Stepper Overcurrent Protection Standard Safi ty'-�-yie­ L/F�s�Problem I .......... 7Automatic ' J- Low Oil Pressure/High Oil Temperature Shutdown Standard SianFda High Engine Temperature Shutdown _ Standard f,iife m-a ITa u-ItA n c—orre cit W i r­tn—g Protection tan Common External Fault Capability Standard St'-an'da'-rd',-'- **Sound levels are talen from the front of the generator Sound levels taken from other sides of the generator may be higher depending on installation parameters Rating definitions-Standby,.Applicable for supplying emergency powerforthe duration of the utility power outage No overload capability is available for ths rating (A I I ratings in accordance with BS5514.IS03046 and DIN6271) *Mmamum kilovolt amps and current are subject to and limited by such factors as fuel Btu/megajoule content,ambienttemperature,allitude,engine powerand condition,etc Maximum power decreases about 3 5 percent foreach 1,000 feet(304 8 meters)above sea level,and alsowi 11 decrease about 1 percentforeach 6 T(10'F)above 16*C(60'F) ENERACO 9/11 kW switch options Limited Circuits Switch Features Model _ G007030-0(9kW) G007032-0(11 kW) r f`Noof�Pblesi,�='•+"�^„�,7;t:,'�n;yK':�?aT,+;:is�.��>`''L�;ft;;`I2i;�.;h"'2��ir ''��4"n„•'ti,a,;��rQ�n-.: ;:;°-°,�� • 16 circuits,breakers not included 0 Current Rating(Amps) 100 100 Rated for all classes of• load,10O%equipment rated,both inductive and Nota";Aaiin"vac`_°+ Y}° ° '•512o/2go;,7 M ;120/240;i s t,�f'.r._.,ga(�u.,).+hF'wnrz. !,���.e�..,..��..,',.�....,.,,.�a�.,�`'icz:..ri.,_. .,,-„__.�,_....:,�x'...h�i resistive. Utility voltage Mondor(Fixed)'a • 2 pole,250 VAC contactors. -Pick-up 80% 60% -Dropout 65% 65% 30 millisecond transfer time. rr r�,,>`”;7zcs;s<r' a,z .; °::, m x;.,',,,,r. „f h;C • rllehim�toU�i4ty.� ' "._ap,Prax �5sec�' V: kapprox'"15'sec{,,,.�,<�,; • Single Coll design, Exercises bi-weekly for 12 minutes*t Standard Standard ' ti M • Main contacts are silver plated or silver alloy to resist welding and sticking. ..a,x�u:�:�:M,:�,'a<�,�,s��;,�t%:';��{;�r�':t�a�''tisra�aaia�,,:�,��� ._",,n,w _ U•,,�,;x,�,x Total Circuits Available 16 16 • NEMA/UL 3R aluminum outdoor enclosure. -� ` - $`�n �' a-' ;Tande`mBreaR0§Pabifities Multi listed for use with 1"standard,tandem,GFCI and AFCI breakers _ + • Circuit Breaker Protected from Siemens,Murray,Eaton and Square D for the most flexible and cost Available RMS Symmetrical 10,000 10,000 effective install Fault Current @ 250 Volts *Function of Evolution Controller Dimensions t Can be set to weekly or monthly W1 Height Width Depth H1 H2 W1 W2 < in 2675 301 105 135 691 MITI 6794 7643 2667 3430 1754 tom?' Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 2/0-#14 2/0-#14 DEPTH I— wz Service Rated Smart Switch Features Model G007033-0(11 kW) d available on 11 kE,d model only • Includes Digital Power Management Technology standard (DPM) Current Rating(Amps) 200 WtaORT,g'(VQ�j". • Intelligently manages up to four air conditioner loads with no additional Utility Voltage Monitor(Fixed)* hardware. -Pickup 60% out 65% -Drop • Up to eight more large(240 VAC)loads can be managed when used in r`-Dropout fa=utii(ry yy"'°`'' °• u''y% ry auapprozsl3sed'`'°.y 4x .�.. - i::`aw C'v:oi;ei;urW)§i'•..!'„!,Idx :..:: w,-.:., i�i'a:A. conjunction with Smart Management Modules(SMMs). Exereses bi-weekly for 12 minutes*t Standard • y - ;1S;c,�^atimr;_�i�^;pu" ;r,• -' „u,.�.a_,.,..Ar 'ir_",. ** Electrically operated,mechanically-held contacts for fast,clean connec- ;Y L steel:':,,•4 ;,, ,r ;.t<i' ;t u <A_,-, 3Staridard,< tions Enclosure Type NEMA/UL 3R Rated for all classes of load, rated,both inductive and ci�cui;Breaker'P�oiecied _' ` ` t rtr''``'22;000`" • -'ter .a::4 . - resistive Lug Range 250 MCM-#6 • Service equipment rated,dual coil design. *Function of Evolution Controller • Rated for both aluminum and copper conductors t Can be set to weekly or monthly • Main contacts are silver plated or silver alloy to resist welding and sticking. W1 • NEMA/UL 313 aluminum outdoor enclosure. Dimensions 200 Amps 120/240,1e �tsa H2 T=.. H, Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 1 2675 30.1 10.5 135 691 mm 6794 -7643 2667 3430 175 4 DEPTH I—W2 GENERACO 9/11 kW available accessories t Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac-t G006463-4 Mobile Link— cess to an Internet connection from a PC or with any smart device. You will even be notified Via e-mail or text message when a change in the generator's status occurs. Available in the U.S.only. G005819-0 k 26R Wet Cell Battery Every standby generator requires'a battery to start the system.Generac:offers the recommended 26R weII ,cell battery for use with all air-cooled standby product(excluding PowerPact@). The pad warmer rests under the battery.Recommended for use if the temperature regularly falls below 01F. 13007101-0 Battery Pad Warmer 1. 1; (Not necessary for use with AGM-style batteries). Oil warmer slips directly over the oil filter.Recommended for use it the temperature regularly falls below G007102-0 Oil Warmer 0°F The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers i iGO07103-0 Breather Warmer only in climates where heavy icing occurs. )Auxiliary Transfer Switch JThe auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load ,GO05621-0 'Contact Kit you may not need.Not compatible with 50 amp pre-wired switches. tThe fascia base wrap snaps together around the bottom of the new air cooled generators.This offers a I G007027-0 Fascia Base Wrap Kit sleek,contoured appearance as well as offering protection from rodents and insects by covering the liffingi holes located in the base If the generator enclosure is scratched or damaged,it is important to touch-up the paint to protect from 13 G005703-0Paint Kit future corrosion The paint kit includes the necessary paint to properly maintain or touch-up a generator ',enclosure. G006482-0-9 kW (Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine fS-cheduled Maintenance Kit Y� 13006483-0-11 kW P maintenance on a Generac:automatic standby generator. 13006664-0 wireless Remote Monitor Completely wireless and battery powered,Generac's wireless remote monitor provides you with instant status information without ever leaving the house.Not compatible with CorePower or EcoGen systems. G006873-0 Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its I, J(50 Amps) power management capabilities.It provides additional power management flexibility not found in any otherl power management system. dimensions & PCs Dimensions shown are approximate,Refer to installation manual for exact dimensions.DO'NOTUSE THESE DIMENSIONS FOR INSTALLATION PURPOSES 1218- 637.fi 148-0 Model UPC G007029-0 696471070293 G007030-0 696471070309 rZ 2- G007031-0 696471070316 G007032-0 696471070323 - 11 iko 0 G007033-0 696471070330 RONNIE,, CAB r256N [48.51M LEFT SEDE MEW FRONT VIEW GENERAL® Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 - generac.corn -mal 02016 Generac Power System,Inc.All rights reserved.All specifications are subject to change wifficut notice Part No 10000000191-D 10/25/16