Loading...
HomeMy WebLinkAbout41429-Z �� �UFFtI(,rCOG Town of Southold 5/5/2017 O P.O.Box 1179 +w 53095 Main Rd Qy��s �p`r Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38927 Date: 5/5/2017 THIS CERTIFIES that the building HOOD FIRE SUPPRESSION SYSTEM Location of Property: 3395 Sound Ave,Mattituck SCTM#: 473889 See/Block/Lot: 121.4-1.3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/16/2017 pursuant to which Building Permit No. 41429 dated 3/16/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: fire suppression system(hood& duct system)in existing winery building as applied for. The certificate is issued to Macari Farm Winery LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED t ed Signature r gUFwt,t- TOWN OF SOUTHOLD BUILDING DEPARTMENT a TOWN CLERK'S OFFICE oy a o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41429 Date: 3/16/2017 Permission is hereby granted to: Macari Farm Winery LLC C/O Lewis & Murphy Realty 47 Hillside Ave Manhasset, NY 11030 To: install fire suppression system (hood & ducts stem) in existing winery building. At premises located at: 3395 Sound Ave, Mattituck SCTM # 473889 Sec/Block/Lot# 121.-1-1.3 Pursuant to application dated 3/16/2017 and approved by the Building Inspector. To expire on 9/16/2018. Fees: COMMERCIAL ADDITION/ALTERATION $250.00 CO -COMMERCIAL $50.00 Total: $300.00 Bit g Inspe 'r 42f OF SOUTyoI � o G • �o ol�COUMV,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) RE ARKS- DATES 9 INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(IST) y -------------------------------------- FOUNDATION(2ND) trJ z C � � ROUGH FRAMING& y i PLUMBING t-� INSULATION PER N.Y. ' STATE ENERGY CODE FINAL ADDITIONAL COMMENTS 0 �z tC m , b TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 / Planning Board approval FAX:(631)765-9502 I 1 (�} Survey SoutholdTown.NorthFork.net PERMIT NO. Check Septic Form N.YSDEC Trustees C 0 Application Flood Permit Examined 20—0 Single&Separate Storm-Water Assessment Form rContact: /� D Approved 20 6 Mail�ill to 1i1 �1^Ci1 T 1 yle, Disapproved a/c M O M P L S D{�- Phone. ' Expiration 2 n Bu'ikfing Inspector APPLICATION FOR BUILDING PERMIT 1� Q D Date M a(Cl V C� ,20 B M A R 1 6 2017 INSTRUCTIONS a This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule JBI=M DEMowing location of lot and of buildings on premises,relationship to adjoining premises or public streets or TO I r covered by this application may not be commenced before issuance of Building Permit d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant Such a permit shall be kept on the premises available for inspection throughout the work t e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. � (Signature of applicant or name,if a corporation) (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder I Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. �9.� Cf 1. Location of an on whmcc propos d work will be ne• f House Number Street p Ha let 1 15 County Tax Map No. 1000 Section V Block Lot r Subdivision Filed Map No. Lot r w +s 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy S A M 3. Nature of work(check which applicable):New Building Addition Alteration X Repair Removal Demolition Other Work (Description) 4. Estimated Cost -4 )�l,by-zl Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. C r-..-V"—A-- 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories yvy Dimensions of same structure with alterations or additions: Front Rear {� Y Depth Height Number of Stories Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase Name of Former Owner �5 L� 11.Zone or use district in which premises are situated JLy► -T'`rc-L-tc. 12.Does proposed construction violate any zoning law,ordinance or regulation?YES NOl 13.Will lot be re-graded?YES NO kWill excess fill be removed from premises?YES NO 14.Names of Owner of premises k b3 A A-&-A-1' Address Phone No. Name of Architect Address Phone No Name of Contractor Ate` 0 yr F, ,LV Address 3 Qf SV Phone No. 14'A-v- 15 v- 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO__V *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO *IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS. COUNTY OF 1� W—cf—t k L p, being duly swom,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, Y O 3 N (S)He is the c (Contractor,Agent,Corporate Officer,etc.) J Z C+7 U y W wof said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application, L - 'S 'F that all statements contained m this application are true to the best of his knowledge and belief,and that the work will be c2 .5 W performed in the manner set forth in the application filed therewith c 'n c - ov o Ci ¢ az _ y SW o o before me this ` E day of Q`c 20 1 1O O o O U � Pu is Si a e o A scant r GENERAL NOTES Koad II INSTALL ALL WORK IN ACCORDANCE WITH THE BUILDING CODE (E5P, y , f JPi De5G1"IJ�IOn Dave SECTIONS 506, 507 AND 508 OF THE MECHANICAL CODE OF ,NEW 155! YORK STATE), NATIONAL FIRE PROTECTION A550CIATION (NEPA), AND O ',',ODI-'L 7AG25 C I'\,1-5 `2i;0 LOCAL LAW 2 HOODS INSTALL ALL HOODS AS DESCRIBED HEREIN a 1� Li ( �3 i_H•I^JGE \IT WTH • ALL HOODS SHALL BE CONSTRUCTED OF No 20 GAGE 5TAINI-ES5 Ci l / �I !SOLD OFffN RETAINER ����� STEEL,OR BETTER \ i • ALL SUPPORTS SHALL BE NONCOMBUSTIBLE AND ADEQUATE TO Q LR A`'-"— -I (I--'?ECEFTACLE-CUT l �y��E SUPPORT ALL ANTICIPATED LOADS, INCLUDING THE SUPPORT OF z COLLLCTOG f_ i ' I c- CLEANING AND MAINTENANCEPEP.50NNEL G ^ • ¢ ; 4 I 'OFT- 5L-RVICE SJ�''TC;i ARCHITECTS hC • ALL SEAMS TO BE WELDED FROM THE EXTERIOR AND BE BOTH' BOX I I + l _ z5 v•ra,anm ,-amaci Hwy su ,e zsoe Holbrook Nr CONTINUOUS AND WATERTIGHT O I ! ING • MAINTAIN A MINIMUM CLEARANCE TO COMBU5TIBL`5 OF 18 INCHES `� �r - _ _ FX R �C? �L DRAWINGS AND ISHED1EN MATERIAL HEREIN CONSTITUTE THE THE ORIGINAL AND UNPUBLISHED WORK OF THE SED wrrH AND THE SAME UNLESS NOTED OTHERWISE ---_-- --_ - - - - - - - ��----I;---- �-� - -�-�- CMAY NOT BE ONSENT OF THE ARCHITECT.USED. OR DISCLOSED 4YITr;(SJT THE WF2RTEN • THE HOOD 5HALL EXTEND A MINIMUM OF G INCHES BEYOND THE VERTICAL PROJECTION OF ALL COOKING 5URFACE5 EXCEPT WHERE THE COOKING SURFACE 15 ADJACENT TO A NONCOMBUSTIBLE WALL OR j !4 X 12" DUCT APFROVALS PANEL 3 GREASE DUCTS DO NOT WRAP OR CONCEAL ANY DUCTWORK A i F1"REbi�� P AROUND DUCT LIGHT TEST HAS BEEN SATISFACTORILY COMPLETED IN THE PR-5ENCE OF THE LOCAL FIRE MARSHAL HAAT 5EIN501R,FOR AUTOMATIC FAN START( I • ALL GREASE DUCTS SHALL BE CONSTRUCTED OF No I G GAGE STEEL OR AFROX(55°-9C°) FAN AL50 'IA 5 MANJAL No 18 GAGE STAIN STEEL,OR BETTER 5UVITCH IN KITCHEN • DUCT JOINTS SHALL BE BUTTED OR OVERLAPPED WHERE OVERLAPPING — EX CEIPNG JOINTS ARE EMPLOYED THEY SHALL BE TALE5COPING OR BELL TYPE _ I INSTALLED TO PREVENT GREASE BUILDUP THE CRO55 SECTIONAL S NOTE. HOOD MAX %'OF!' F=LI1JC'F DIMENSIONS OF THE OVERLAPPING SECTIONS SHALL NOT EXCEED ONE L-- - - - — ANOTHER BY MORE THAN 0 25 INCHES • ALL SEEMS IN DUCTWORK TO BE WELDED FROM THE EXTERIOR AND BE HOOD (5'-0"X 24"x 42" BOTH CONTINUOUS AND WATERTIGHT p� �4 FP • WELD GREASE DUCT TO HOOD UNLESS NOTED OTHERWISE AP '�t..p ? T D ��r� • DUCT TO GASKET D EXHAUST FAN CONNECTIONS SHALL BE FLANGED AND • WHERE EMPLOYED,VIBRATION 150LAFION CONNECTORS SHALL CONSIST C�P.TE�_�L/ � 4- A OF NONCOMBUSTIBLE PACKING IN A METAL SLEEVE JOINT UNLESSOTHERWISE LISTED FOR SUCH APPLICATION. ISOLATION CONNECTORS g SHALL INSTALLED IMMEDIATELY ADJACENT TO THE FAN UNLESS NOTED OTHERWISE :1FY BUILDIN:a GPAT • ALL DUCTS SUPPORTS 511ALL BE NONCOMBUSTIBLE AND RATED FOR ANTICIPATED LOADS BOLTS, SCREWS, RIVETS OR OTHER FASTENERS 0 gFiN 1u0" 8 AFA T(; 4 Pr\i FOR T!iF PROJECT SHALL NOT PENETRATEPUNS UP THE DUCT WALL? -- Ji ^e'^ I!�Sr�G'IUINo: ALL OUT FIRE • HORIZONTAL R D S UP r 75 FEET IN LENGHT SHALL HAVE AMINIMUM - err RETAIN STORM WATER RU OFF 5LOPE TOWARDS THE HOOD OF 025 IN 12 (2%) WHERE THE 1. FOUNT f ION - X40 REQUIRED HORIZONTAL RUN EXCEEDS 75 FEET THE MINIMUM SLOPE INCREASE I IN - FC i F�uRED CONCRETE PURSUANT TO CHAPTER 236 12(53%) �-= �; 585 HIGh 5T, DO NOT INSTALL FIRE DAMPERS OR OTHER DEVICES THAT WILL a 0©re?o a o I' 2- ROUGH - FRAMING & PLUMBING OF THE TOWN CODE. OBSTRUCT THE AIR FLOW OR IMPEDE GREASE MOVEMENT �_ q T H OL5ROOK, NY 1 1741 j MAINTAIN A MINIMUM CLEARANCE TO COMBUSTIBLES OF 18 INCHES 3. INSULATION NOTED OTHERWISE '' ! ! 4. FINAL - CONSTRUCTION MUST GLENN (63 1) 580-0303 • ACCE55 DOORS PROVIDE ACCESS DOORS WHERE ANY PORTION OF ! THE DUCTWORK CANNOT BE REACHED FROM THE DUCT ENTRY OP �� BE ( ETE FOR G.O. LIC#: 124 DISCHARGE REGARDLE55 OF ANY OTHER PROVISION, ACCE55 DOORSj� �� �� �slJfll I,r�c-evPrcc-� HC i-�i WILL BE PLACED EVERY 20 FEET ALONG HORIZONTAL RUNS IN SUCH A - J' --A�1-�� FASHION THAT THE OPENING IS A MINIMUM OF 1 5 INCHES FROM THE REQUIREMENTS OF THE CODES OF NEWBOTTOM OF THE DUCT AND I INCH FROM THE TOP OF THE DUCT HOOD AND DUCT 55YTEM ACCESS DOORS SHALL HAVE A MINIMUM DIMENSION OF 12 INCHES YORK STATE. NOT RESPONSIBLE FOR SQUARE, BE TIGHT FITTING, HAVE A THICKNESS NO LE55 THAN THAT '6 iif P � I �� \ DESIGN OR CONSTRUCTION ERRORS. REQUIRED FOR THE ASSOCIATED DUCTWORK, HAVE A SUBSTANTIAL z ( ! + ;-`'R �9 .x --- MACAKI VINE YARDS METHOD OF LATCHING AND BE OPERABLE WITHOUT TOOLS ALL F1RE INSPECT`I PN 150 BERGEN AVE, COMPONENTS OF THE ACCESS DOOR SHALL APPROVED FOR THE �J �` �� � � BEFORE MATTITUCK, NY, 1 1952 PURPOSE S'_,'�LE Pu.T �' • AIR VELOCITY WITHIN AI_L GREASE DUCTS SHALL BE NO LE55 THAN 500 FEET PER MINUTE(FPM) g 4 EXHAUST FANS EDDIE MAZARI (G3 ;) 703-4072 • THE DISCHARGE OF VERTICALLY EXHAUSTING FANS SHALL BE A MINIMUM Of 40 INCHES THE ROOF E7UPfACE AND 1 ZONTALLY FFROMANY BUILDING INTAKE HORIZONTALLY EXHAUOTING FAFEETONSWILL NOT COMPLY WITH ALL NEW CODES OF SEAL SIGNATURE BE PERMITTED UNLESS NOTED OTHERWISE YORK STATE & TOWN CODES • EXHAUST EQUIPMENT SHALL BE OF AN APPROVED DESIGN OR LISTED NEW FOR THE APPLICATION AS REQUIRED AND CONDITIONS OF • MAINTAIN A MINIMUM CIFARANCE TO COMBUSTIBLE OF 18 INCHES 9 -42" • FAN TO AUTOMATICALLY ACTIVATE WIHENEVER COOKING 15 IN EXf!AU�+i- A PROGRESS INTERLOCK WITH COOKLINE U51NG TEMPERATURE SENSORS ! Ji �Aa SL1I� �!® r1RC�i� OR OTHER APPROVED METHOD V V 1 I1II GREA5E FILTER >> HOOD �� SOUTHOLD T ���QN GABRF 5 MAKEUP AIR PROVIDE MAKEUP AIR AS REQUIRED BY SECTION 508 OF 1 THE MECHANICAL CODE OF NEW YORK STATE ALL MAKEUP AIR — (� DUCTWORK WITHIN 18 INCHES OF THE HOOD SHALL BE f GREASV�ITH - [e Q NONCOMBUSTIBLE � D(�AII!OR RATED FOR SUCH USE ALL INTAKES TO BE A GREA5 REMOVABLE CUP CJ MINIMUM DISTANCE OF 10 FEET FROM ANY BUILDING EXHAUST AND 3 FEET FROM ANY PROPERTY LINE N• G CURB AND FLASH ALL PENETRATIONS AS REQUIRED �G o 7 INSTALLER SHALL VERIFY CAPTURE AND CONTAINMENT PERFORMANCE S No. 01634i�, � OF THE EXHAUST SYSTEM SUCH VERIFICATION SHALL OCCUR WITh ALL I T�1 r� SOURCES OF OUTDOOR AIR PROVIDING MAKEUP AIR FOR THE HOOD OCCUPANCY®R 1 4 OPERATING AND WITH ALL SOURCES OF RECIRCULATED AIR PROVIDING CONDITIONING FOR THE SPACE OPERATING QUANTITATIVE TESTING SHALL VERIFY THAT SPECIFIED EXHAUST RATES HAVE BEEN ACHIEVED USE I� UNLAWFUL QUALITATIVE TESTING SHALL VERIFY THAT FUMES PRODUCED �. BY 51MULATED COOKING, SMOKE CANDLES OR OTHER APPROVED DA 03-03- 17 MEANS ARE ADEQUATELY CAPTURE WITHOUT-CERTIFICATE" 8 FIELD VERIFY ALL DIMENSIONS AND CONDITIONS NOTIFY ENGINEER OF JOB O: ANY DISCREPANCIES OR VARIATIONS FAILURE TO 50 NOTIFY ENGINEER P^ g� VIEW �} -, OF OCCUPANCY \120 WING BY: D5 SHALL BE AT INSTALLER'S SOLE RISK �"/9 4! �'\�!f\!!/ NOTE _ ChK BY: JG ALL WOOD FRAMING _'� u--- 511-ALE: N.I .5 DWG BY: I OF I MINIMUM PIPE VOLUME5 FORA FRYER, RANGE AND WOK CYLINDER SIZE AT OR BEFORE FIRST APPLIANCE Jit° 3/8, I55ue Description Date 8'-0'I l_I GOO 18OML- I FLOW POINT 3 OFT 4.8FT 12" X 12" I L3000 239ML- 2 FLOW POINTS 4 OFT G.4Ff DUCT L4GOO 180ML- 2 FLOW POINTS 3.OFT 4 5fT rd G/SEPIA p P/N MCHZ L0000 120ML- 2 FLOW POINTS 2.OFT 3 2Fl �dCHIT� T5,PC IA FUSIBLEI D ' <z5° Veterans Memorial ARCHITECTS,I�Cook NY LINKS CONTROL HEAD — 1 ALL GINNALL ANO UNPUBUSHED WORK OF THE ARCHRECf AND THE SAME PRO ] MAY NOT BE DUPLICATED, USED, OR DISCLOSED WRHOUr THE WRlTrEN – – – TEX AES MANUFACTURER: CONSENT OF THE ARCHITECT. I H SET — , APPROVALS HOOD 8'-0" x 24" x 42" ' ' PROTEX II _ L-I GOOD—L3000 L4000 L3000 ' _ I � SALAMANDER I 1z PIPING MATERIAL• BLACK 5CH 40 MAX RISE: 10' fo ,vl L �' �,Q I SUPPLY PIPE SIZE: /2" BRANCH PIPE SIZE: 3/(5" o c o I z�J GAS VALVE TYPE. IV CH 51ZE. 1%' MANUFACTURER: PROTEX I I J, 32 01= a I DET ECFOI?.TEMPEF'�AI URE RATING 360° (2) STICKER IL 11L IL U�— -- HOOD SIZE: 8'-O' r. 24" x 42" DUCT SIZE: 12" X 12" PROTEX II L3000. 10 FP/BRANCH MAX PROJECT 0 0 0 @ o 0 0 0 MAX. FLOW POINTS = 10 ALL OUT FIRE MAX. PIPE VOLUME = 19 10 ML I MAX VOLUME BETWEEN FIRST AND 9 O� LASF NOZZLE 1 125 ML PER BRANCH 585 HIGH ST, 1 HOLBROOK, NY 1 1741 TOTAL PIPE MAX PIPE LENGTH ( 3/8" ) GLENN (G3 1) 580-0303 FLOW POINTS: G I CYL;NDER SIZE L3000 MAX PIPE LENGTH 50.93FT LIC#: 124 FROM FIR5T NOZZLE TO LAST NOZZLE MAX PIPE LENGTH: 30.00 FT SYSTEM DIAGRAM 3E." OVEN TOTAL PIPE MAX P101E %2 LENGTH ( ' ) MACARI VINE YARDS G BURNER RANGE CYLINDER SIZE L3000 150 BERGEN AVE, MAX PIPE LENGTH 31 94 FT MATTITUCK, NY, 1 1952 FROM FIR5T NOZZLE 1-0 LAST NOZZLE EDDIE MAZARI 5Y5TE AIvl DIAGRAM IAGM M AX PIPE LENGTH: 18.8 1 FT (G3 1 ) 793-4072 I C SCALE: 1/2"= P-o" SEAL SIGNATURE I NOTES SHELF PROTECTION I R�� ARC — FRYERS TO HAVE HIGH LIMIT CONTROL TO SHUT OF FUEL AT 425°. — DETECTORS SHALL BE LOCATED OVER EVERY PIECE OF EQUIPMENT SHELF — THE SYSTEM INSTALLED AS PER MANUFACTURERS SPECS AND THE AHJ. NOZZLES — THE SYSTEM HAS BEEN INSTALLED AS PER UL300 NOZZLE SURFACE y�► — THE FOLLOWING OPTIONS TO OPERATE UPON SYSTEM DISCHARGE: 1 L EQUIPMENT QTY AREA a SUPPLY AIR DAMPER CL05E5 I PART; HEIGHTS LOCATIONS ® EXHAUST FAN REMAINS ON ' �T ° 0163 • ALL SYSTEMS TO ACTIVATE SIMULTANEOUSLY IN SAME I DUCT 1 12"X 12" NL I D 1001, CENTERLINE HAZARD AREA. PLENU141 I 4X 12 NL I H 120" CENTERLINE o FIRE ALARM SHALL ACTIVATE ® GA5 FUEL SHUTS OFF IN KITCHEN. G BURNIER RANGE 3 3G"X 24" NL I L 10"-24" CENTERLINE ELECTRIC FUEL SHUT OFF UNDER HOOD HAZARD SALAMANDER 1 32"Y2411 NL I L FRONT EDGE ABOVE GRATE MANUAL PULL 15 LOCATED A MAXIMUM 20FT FROM HOOD AND 4FT D E: 03-03- 17 FROM FLOOR B No: — ALL FUEL SOURCES ARE GAS UNLESS OTHERWISE NOTED — ALL JOINTS AND CONNECTIONS WILL HAVE PIPE TAPE DRAWING BY: DS — ALL WOOD FRAMING CHK BY: JG DWG BY: I OF I