Loading...
HomeMy WebLinkAbout41612-Z ��p�guFFOt,�Co�� Town of Southold 5/8/2017 P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38928 Date: 5/8/2017 THIS CERTIFIES that the building WINDOWS Location of Property: 590 Haywaters Dr, Cutchogue SCTM#: 473889 Sec/Block/Lot: 104.-5-22 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/8/2017 pursuant to which Building Permit No. 41612 dated 5/8/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"windows in an existing one family dwelling as applied for. The certificate is issued to Schott,Barbara&Schmitz,William of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED u ho d Signature o�gUFFnt�cvTOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy SOUTHOLD, NY poi ,�ao f BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41612 Date: 5/8/2017 Permission is hereby granted to: Schott, Barbara & Schmitz, William 1235 Cedar Dr East Marion, NY 11939 To: as built" windows in an existing one family dwelling as applied for. At premises located at: 590 Haywaters Dr, Cutchogue SCTM #473889 Sec/Block/Lot# 104.-5-22 Pursuant to application dated 5/8/2017 and approved by the Building Inspector. To expire on 11/7/2018. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $400.00 CO-NEW CONSTRUCTION/ALTERATION/REPAIR $50.00 Total: $450.00 Building Inspector _ ._ _ Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of•Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9,1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. - A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building= $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. �r 2 o 1 -7 New Construction: Oldor Pre-existing Building: � (check one) Location of Property: 5q© YA Y ld fi I S(2s T)R_ C C-[i C406C4(� House No. Street Hamlet Owner or Owners of Property:V/1_6fi n SGffm 17 Z (-&/'Z$RZR Sc#off ► 0 R61A)IR PIZ-3 Suffolk County Tax Map No 1000, Section 113(72q Block 10,-/, S Lot 2 Z Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ Applicant Signa TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applymg? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 1 I Planning Board approval FAX: 631 765-9502 `� Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S D E C Trustees C O.Application Flood Permit Examined / 20 Single&Separate Truss Identification Form Storm-Water Assessment Form /f/ Contact: � r Approved '20 Mail to of L I.1 R' 9M .�c KM!i Z �7 Disapproved a/c_J_ Z(p Hflrrt 19T0-N Coct.R(CegzAm plf Phone: 63 t1 4 ir -Expiration -020 �!D� D155 29 uilding=1DIENSIG or MAY _ 8 2017 LICATION FOR PERMIT J Date Jr—/� ,20 BUMDING DEPT. INSTRUCTIONS TO i�l�' h� completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate p of p an o scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit d Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant Such a permit shall be kept on the premises available for inspection throughout the work. e No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections z&& (Signature of applicant or name,if e*oration) (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder Name of owner of premises R R G Oil UJ1LLl,F4Y'l SG ,-4 r( Y (X) -2 (As bn the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: S70 HP RVLM-ERS D2 Cu 71h106Y HouseStreet �� Hamlet County Tax Map No. 1000 Sectiony13 tr1.3 2 Block �0 q o C Lot �Z Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work RE TUCL W l xiboW-5 (Description) 4. Estimated Cost �� c� LJ Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front l D 3, �1 Rear ©�. Depth 7 q 0 3 P 10.Date of Purchase /c 53 Name of Former Owner 11.Zone or use district in which premises are situated 12.Does proposed construction violate any zoning law,ordinance or regulation?YES NO'?<— 13.Will lot be re-graded?YES NOKWill excess fill be removed from premises?YES NO 14.Names of Owner of premiseVILLI Ano 5cA m i'tZAddress C 5RAK P Y LLMPhone No. 631 8 4$ 7 71 Name of Architect Address —�Phone No Name of Contractor Address Phone No. 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO *IF YES;.SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO *IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF being duly sworn,deposes and says that(s)he6b ba%UNCH (Name of individual signing contract)above named, Notary Public,State of Now York (S)He is the No.01 SUB185M (Contractor,Agent,Corporate Officer,etc) Commission Expires April 14,2 b�Q of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith w m to before me this day of 20 1--) Notary Public Signature of Applicant r" .. L• r W I N D O W S Andersen.M WINDOWS-DOORS Unit Sizes e • e • Note: Single sash Indicates hinging left, right or stationary Handing is viewed from exterior. Unit Dimension refers to overall outslde- t0-oUfSlde frame Unobstructed Glass refers to visible glass dimensions Numbers In parentheses are metric measurements See 1`1 3,acmirinrl Visible Glass Vir,'Jeo See current Size Grid Table of Casement and Transom Window Sizes Scale'A"(3)=1'-0"(305)—1.96 Window M-mlon 1 5' 1 e V,° 2 OUG' TAM" 2'71/1" 2'110AG° 2'9311" 3'-43/a' 4'0" (,J32) Ih2 Jj (613) j721) (000) (913) (857) (1035) (1219) 1 (1435) Mum—, 1'S3k 3'9" 2'-0=4." 2'43:14 2'8" 3'OUe' 2'10th' 3'-5te" 4'-0t12" ` 4'-9° Rough Openmg (145) (533) (625) (733) (813) (927) (870) (1048) (1232) (1448) URGbslmctcd Gloss 12s IG',a" 19'4" 24" 27t/s" 31 VV 12'A' 1GUG" 1911.' � I 24" lu,-irnml.m3le s;ra+ant.� (3211 (110) (502) (610) (689) (602) (321) (410) (502) (610) UnobsWcled Glass 123hn" lr 3 '4 1_9s L1111 23 RAs" 1vv"26t3hs" 32!Es 35-W 43uhF" 51 t3hn" +o-nuan slreesnb omd (3107 (398) (491) 15991 (678) (791) (735) I (913) (1097) 1 1 (1313) CIRI510 C1R1810 CTR2010 CT8241R2410 CTP281810 CTR3010 CRt2910 CTR3410 CTR4010 CTR4810 CTR21810 CTR22010 CTR22410 CUS70;•J IVIOTFtS—1'-5"[02'173Sir`- - ,. ' x Z. u ! ___ CR12 CN12 C12 Cw12' CN22 122 CW22' 0I IC� 11 _ Z, CR125 CN.25 C125 CW125' CX125 CN225 C225 014225' Mi LIT al 01, ,__31, F1 ,0_,--- --T -4-k ON CR13 C1113 C13 CW13' CX 13 CXW 13 CR23 CN23 C23 CW23' 11i'lirl i 'r--U01_1_11�� 1 �fi [[- 11[� Inn ' CRI35 CN135 C135 C411351' C%135' C111135' CR235 111235 C235 114235' 103 11,71D] [JIL CRt4 ON 14 014 CW74'. CXJ4' CAV 14' C64 CN24 \124�' CW24" CRA 6 ON 145 1745 CIV745' 1X145CXW145' CR245 CN249 C245 M245 V71, r La-- u �M i l� j Ll CRIS CN 15 C15 Owls, CX15'• CXVVI9 ' CR25 CN25 C25 CW25" ij OR 155 fN155 1155 Cw155•' C%155' 1%47155" CP255 111255 1255 CW255"J 1-- -,- CR16 ON 16 C16 Cw16" CX 16, CX'W161" CR26 CN26 C26 CW26+' Vent Layout Perma-Shield®Improved/E-Z Casement Standard and Transom Window Unit Sizes Unit viewed from exterior 10-400 Series Perma-Shield®Improved/E-Z Casement Windows(1999 to Present) `U.S", Canada ,e r -ENERGY' ENERGY C91'., 1, '",i'y,1' ',j€, i .ti - *6, ,y - ,• ca, 5,1, ",STAR, ' TAR', ,N�RCCartifled' ,o Dov'. 'm �` Andersen' Andersen _ ` ,ty - 'v 6.0,,. 'v4. 4ProductLlneB"' LGlass' Grlite'Type' ;' Products",, Product Type Type A .Directory Number "n 4 m is - {.j"; .},,. t: , ,S7 ` flV ',C c' '� kL 2.2 Annealed Glass-w/No Grilles and Grilles Less Than V No Grilles AND-114101145-00001 0.28. 1.59 032'`0.54 23 1 <0.2 IM NO 1 111iIII W Simulated Divided Lite or Installed Interior Removable AND-1,14-01145-00002 0.28 1.59 0.29 049 22 <0.2 - NO - - lIZ111- 9 Full Divided Lila AND-N-1-01163-00001 0.29 1.85 0.29 049 20 <0.2 - NO - - - FinelightTM(grilles-betweendh"law) AND-N-1-01151-00001 0.28 1.59 029 049 22 <0.2 - NO - Z1 - No Grilles AND-1,14-01146.00001 028 159 020 0.30 17 <0.2 - NO SC S Z1 - c Simulated Divided Lite or Installed Interior Removable AND-144-01146-00002 028 159 018 0.27 15 <0.2 NO SC S - w ,9 Full Divided Lite AND-N-1-01164-00001 0.29 1.65 018 0.27 14 <0.2 - NO SC S - - - Finelight-(grilles-between-theglass) AND-N4-01152-00001 0.28 1.59 0.18 0.27 15 <02 - NO SC S - - No Grilles AND-N-1-01147-00001 0.27 153 0.21 0.49 18 <02 M NO SC S 111,111- - ! c Simulated Divided Lite or installed Interior Removable AND-1,14-01147-00002 027 153 0.19 044 17 <0.2 ,(wj NO SC S Ill- EE028 - - 0 Y s m Full Divided Lite AND-N-1-01165-00001 0 28 1.59 0.19 044 16 <0.2 - NO SC rn Finelight-(gniles-between4heglaw) AND-N4-01153-00001 027 1.53 0.19 0.44 17 <0.2 68 NO SC S Z1 - - No Grilles AND-1,14-01144-00001 029 165 0.52 0.60 34 <0.2 !wI - - - Z1 I Z3 11 �w Simulated Divided Lite or Installed Interior Removable AND-1,14-01144-00002 029 1.65 BAB 054 31 c 0.2 ,g Full Divided Lite AND41-1-01162-00001 0.29 1.65 048 0.64 31 <0.2 GJ - - Zi Z2 a FinelightTM(gniles-batween-theglass) AND-N-1-01150-00001 0.29 1.65 048 054 31 <02 q - - - Zi Z2 - ! No Grilles AND-N4-01246-00001 0.24 1.36 0.31 0S3 28 <0.2 G8 NC1 11 11- 21 Z2 s n•ay Simulated Divided Lite or Installed Interior Removable AND-N-1-01246-00002 024 1.36 028 0.48 26 <0.2 q NO - - Z7 I Z2 1 11 9 m Full Divided Lite ANDdl-1-0125540001 026 1A8 028 0.48 24 <0.2 G) NO - - Z7 - - Finelight-(grilles-between-theglass) AND-N-1-01249-00001 024 136 028 0.48 26 <0.2 09 NO - - Z1 Z2 - ! No Grilles AND-1,14-01247-00001 0.24 1.36 0.21 BAB 22 <02 (wj NO SC I S I I Z7 Z2 - eaai Simulated Divided Lite or Installed Interior Removable AND-1,14-01247-00002 0.24 136 0.19 0A3 21 40.2 NO SC S Z1 Z2 - Full Divided Lite AND-N-1-01256-00001 025 142 0.19 043 20 <0.2 IO NO SC 5 Z7 400 Series 3 - Casernent $ FinelightTM(grilles-between4h"lass) AND-114-01250-00001 0.24 1.36 0.19 043 21 <0.2 NO SC 5 Z7 Z2 - c No Grilles AND-1,14-01245-00001 0.25 1.42 0.48 0.58 36 <0.2 10 - Z7 Z2 73 °aW Simulated Divided Lite or Installed Interior Removable AND-N4-01245-00002 025 1.42 0.44 0.53 34 <0 2 1z, Z2 Z3 i Full Divided Lite AND.N-1-01254-00001 026 1.48 0.44 0.53 33 <02 94 - - - Z2 Firelight"(grilles-betweeMheglass) AND-N-1-01248-00001 025 1.42 OA4 0.53 34 <02 09 - Z2 Z3 2.2 Annealed Glass-w/Grilles V or Greater Simulated Divided Lite or Installed Interior Removable AND-1,14-01145-00003 028 1.59 0.26 0 44 20 <0.2 - NO - e Full Divided Lite AND-N4-01169-00001 029 1.65 026 044 19 <0.2 - NO - - - FinelightTM(grilles-between,theglass) AND-01-1-01157-00001 029 1.65 0.29 0.49 20 <02 - NO - - Simulated Divided Lite or Installed Interior Removable AND-N-1-01146-00003 028 1.59 0.17 0.25 15 <0.2 - NO SO S - - N Full Divided Lite AND-N-1-01170-00001 0.29 1.65 0.17 0.25 13 00.2 - NO SC S - 9 FinelightTM(grilles-betweendheglass) AND-N-1-01158-00001 0.30 1.70 018 0.27 13 <02 NO SC S - - p Simulated Divided Lite or Installed Interior Removable AND-N4-01147-00003 0.27 1.53 0.18 0.40 17 <0.2 G} NO SC S 21 - - � e N r Full Divided Lite AND-01-1-01171-00001 0.28 1.59 018 BAD 15 <02 - NC '11911 - - 9 " w FinelightTM(grilles-between-the-glass) AND-N-1-01159-00001 029 155 0.19 044 15 <0.2 - NO SC S - - - ® Simulated Divided Lite or Installed Interior Removable AND-N-1-01144-00003 0 29 1.65 0.43 0 49 29 <0.2 c - �' Full Divided Lite AND-1,14-01168-00001 029 1.65 OA3 0.49 29 <0.2 - S a FinelightTM(gnllesaietween4heglaw) AND-N4-01156-00001 0.30 1.70 0A8 0.54 30 <0.2 Zi Z2 s Simulated Divided Lite or Installed Interior Removable AND-N4-01246-00003 0.24 1.36 o26 043 25 <0.2 30 NO - - Z1 Z2 - 9 'm Full Divided Lite AND-N-1-01258-00001 0.26 1.48 026 0.43 22 <10.2 �M Be NO - 21 - 3 FinelightTM(grilles-betweendheglass) AND-N-0-01252-00001 0.25 1.42 0.28 048 25 <02 NC - - Z1 - Y Simulated Divided Lite or Installed Interior Removable AND-N4-01247-00003 0.24 1.36 0.17 039 20 < NC SCZt96Full Divided Lite AND-N4.01259-00001 025 142 017 039 19 < NC SCZtis Em 3FinelightTM(grilles-betweentheglass) AND-014-01253-00001 0.25 1 42 019 0.43 20 < NC SC 5 Z1 Page 2 of 155 Data Is current as of December 15,2014 and is subject to change. See page 1 for more information W I N D O W S Andersen-MM WINDOWS" DOORS Unit Sizes U rdt Size Chart I 'Aft Note: Unit Dimension refers to overall outside-to-outside frame Unobstructed Glass refers to visible glass dimensions See Met:suring Visible Glass Video See Product Details Table of Basic Unit Sizes—Tilt-Wash Double-Hung Windows Unit Dimension 1'-7 1/2" 1'-11 112" 2'-3 1/2" 2'-7 1/2" 2'-11 1/2" 3'-3 1/2'• (495) (597) (G99) (800) (902) (1003) M1 IMom 1'-8" I 2'-0' 2.4° 2'_8" 3'-0" 3'-4" Rough Opening (508) I (610) (711) (813) (914) (1016) Unobstructed Glass 13 1/2" 1 17 1/2" 21 y2" 25 1/2" 29 1/2"i 33 1/2" (343) I (445) (546) (648) (749) (851) m ,� LEI 244DH1830 244DH2O30 244DH2430 244DH2830 244DH3030 244DH3430 � it �'_� Imo; 1�.1 I 1 n cu M { _ 244DH1836 244DH2O36 244DH2436 244DH2836 244DH3036 244DH3436 3 fff i I ! 244DH1840 244DH2O40 244DH2440 244DH2840 244DH3040 244DH3440 FA__ 244DH1846 244DH2046�244DH2446 2401-12846 244DH3046 244DH3446 [L--J] 244DH18119 244DH2O49 244DH2449 244DH2849 244DH3049t 244OH3449t n L-LI 24411I(D[1-1850 244DH2O50 244DH2450 244DH2850 244DH3050t 244DH3450t H-ill , in co co. n I �.'jam. i, ,1. 244DH1856 244DH2O56 244DH2456 244DH2856t 2440H3056t 244DH3456t v 1— '-II ll Lj 244DH1860 244DH2O60 244DH2460 244DH2860t 244DH3060t 244DH3460t 200 Series Tilt-Wash Double-Hung Window Unit Sizes Unit viewed from extenor 6-200 Series Tilt-Wash Double-Hung Windows(2000 to Present) 1/31/14 s- Canada °., _ .. -_ �'„ •ENERGY ENERGY,' ;,.;;y. S y c ? _ ,x ;�r o STAR f START;,x iAnderson-' Andersen 'T "_S' _ W ti6.0 v4.1% NFRC Cettlfled' o o m Product Llne&' Glass. Gdlle Type Products ;, ,as,'g' `CD Product Type ^DifectoryNumber,, � %� ;rn 3 ,, L n � 'L' 't.= N..W 7 75 q ZN` t 2.2 Annealed Glass-w/No Grilles and Grilles Less Than 1" No Grilles AND4459-00849-00001-0.29 1.65 .0.32` 0.55 - 22 <0.2 NC - -- - W Simulated Divided Lite or Installed Interior Removable AND4159-00849-00002 029 1.65 0.29 0.49 20 <0.2 Full Divided Lite AND4159-00855-00001 0.31 1.76 029 049 17 <0.2 - - - - - FinelightTM(grilles-between-the•glass) AND•N.6900867-00001 0.30 1.70 0.29 049 19 <0.2 - NC - - - - No Grilles AND.N59-00850-00001 0.30 1.70 0.20 030 14 <02 - NC SC S - - Y c Simulated Divided Lite or Installed Interior Removable AND-N59-00850-00002 0.30 1.70 018 0.27 12 <0.2 - NC SC S - - m Full Divided Lite AND-N59-00858-00001 0.31 1.76 018 027 11 <0.2 Finelight"r(gnlles-between-theylass) AND44.59-00868-00001 0.31 1.76 0.18 0.27 11 <0.2 - S - No Grilles AND.N59-00851-00001 029 1.65 0.21 0.49 15 <0.2 - NC SC 5 W$H Simulated Divided Lite or Installed interior Removable AND-N•59-00851-00002 029 1.65 0.19 044 14 <02 - NC SC 5 - - F Y 3 E Full Divided Lite AND-N59-00857-00001 0.30 1.70 0.19 0.44 13 <0.2 - NC SC E Fnehght"'(grilles-between-theglaw) AND-N59-00869.00001 0.30 1 1.70 0.19 0.44 13 <0.2 - NC IS.1 11 S - - No Grilles AND-N5940848-00001 030 1.70 053 060 33 <0.2 c w N Simulated Divided Lite or Installed Interior Removable AND-N59-00848-00002 030 1.70 047 0.54 29 <02 - Z7 Z2 i Full Divided Lite AND-N59-00854-00001 0.31 1.76 047 0.54 28 <0.2 - - - Zt - a. FinelightTM(gnlles-between-the-glass) AND-N59-00866-00001 0.31 176 0.47 0.54 28 <02 - - 21 ! No Grilles AND-N-59-00969-00001 0.28 159 031 054 22 <0.2 - NC - - Z1 - Y t3� Simulated Divided Lite or Installed Intoner Removable AND-N59-009B9-00002 0.28 1.59 0.28 OAS 21 <0.2 - NC - - Z1 f z Full Divided Lite AND-N59-00972-00001 028 159 0.28 OAS 21 <0.2 - NC - Zt - - 3 FinelightTM(grilles-between4beglass) AND•N59-00978-00001 0.28 1.59 0.28 OAS 21 <0.2 - NC - - 1Z111- - 2 No Grilles AND-N-59-00970-00001 028 1.59 021 048 17 <0.2 - NC SC S Z1 I I- - Y m Simulated Divided Lite or Installed Interior Removable AND4159-00970-00002 028 119 0.19 0.43 15 <02 NC SC S v 200 Series E x Full Divided Lite AND-N59-00973-00001 0.28 1.59 0.19 043 15 <0.2 - NC SC S - Tilt-wash 3 Double-Hung FinelightTM(gnlles•between4heglass) AND-N59-00979-00001 0.28 159 019 0.43 15 <0.2 - NC SC I S - 2 No Grilles AND-N59-00968-00001 0.26 148 0.48 059 35 <02 Y w Simulated Divided Lite or installed Interior Removable AND-N59-0g968-00002 0.26 1.48 0.43 052 32 <02 v m x Full Divided Lite AND-N59-00971-00001 029 165 0.43 0.52 28 <0.2 ;( - - ILL FinelightTM(gnlles-between4hegiass) AND.N59-00977-00001 0.29 1.65 OA3 052 28 <0.2 I - 2.2 Annealed Glass-w/Grilles 1"or Greater Simulated Divided Lite"Installed Interior Removable AND-N59-00849-00003 029 165 0.26 043 18 <0.2 - NC - - - �3 Full Divided Lite ANM59-00861-00001 0.30 1.70 0.26 043 17 <0.2 - NC - Fmelight^'(grilles-betwesn-theglass) AND-N-5"0873-00001 031 1.76 029 049 17 <0.2 - - - - - - - Simulated Divided Lite or Installed Interior Removable AND-N59-0D850-00003 0.30 1.70 016 024 11 <0.2 - NC SCIIS - - W �e Full Divided Lne AND-N5940862-00001 0.31 1.76 0.16 0.24 10 <02 - - - S - -j FinelightTM(gnlles-0etween-theglass) AND-N59-00874-00001 0.32 1.82 0.18 0.27 10 <02 [ Simulated Divided Lite or Installed Interior Removable AND-N59-COM-O0003 029 1.65 0.17 0.39 13 <0.2 - NC - c $ Y Full Divided Lite AND-N59-00863-00001 0.30 1.70 017 039 12 <0.2 - NC SC 5 - - s E v+ FinelightTM(grilles-between-theglass) AND•td59-00875-00001 0,31 176 0.19 0.44 12 <02 - I SIII11 - I. Simulated Divided Lite or Installed Interior Removable AND-N-59-00848-00003 030 1.70 0.42 047 26 <02 ( - -IIIZIII- W� $ N Full Divided Lite AND-N59-00860-00001 0.31 1.76 0.42 0.47 25 <0.2 - - - - Z7 s a Fnelight-(gnlles-between4heglass) AND4d39-00872-00001 0.32 1.82 0.47 0.54 27 <0.2 - - - Z1 I - s Simulated Divided Lite or Installed Interior Removable AND-N59-00969-00003 0.28 1.59 025 0.42 19 <0.2 - NC SC S Zt - - W qq v Full Divided Lite AND-N-59.00975-00001 0.28 159 025 0.42 19 <0.2 - NC SC S Z1 - x 3 FinelightTM(gdlies-between-theglass) AND-1159-00981-00001 0.28 1.59 0.28 0.48 21 <02 - NC - Z1 W = Simulated Divided Lite or Installed Interior Removable AND-N-59-00970-00003 0.28 1.59 0.17 0.38 14 <02 - NC SC 9 S 9 Full Divided Lite AND-N59-00976-00001 0 28 159 0.17 0.38 14 <02 - NC SC S - E _ N 3 FinelightTM(gnlles-between-theglass) AND-N59-00982-00001 028 1.59 0.19 0.43 15 <0.2 Page 2 of 55 Data is current as of December 15,2014 and is subject to change Sae page 1 for more Information 400 Perma-Shield° Improved/E-Z Awning Windows (1999 to Present) Standard, Picture, and Transom Windows Unit Sizes • • Wi n• s Note: Direction of hinging shown is standard Opening is viewed from exterior Unit Dimension refers to overall outside-to-outside frame Unobstructed Glass refers to visible glass dimensions Numbers in parentheses are metric measurements Colonial grille pattern shown See N-masurir q Visibia Glass Video Unit Dimension 2'-01/8° 21-43/6° 2'-71/9" 2'-1115/1." 3'-413/16 4'-0" 4'-413/16" 4'-117/8" 5'-413/16" 5'-117/8" (613) (721) (803) (913) (1037) (1219) (1341) (1521) (1646) (1826) Rough Opening IT-05/d" 2'_4 7/6" 2'_8" 3'_0172" 3'_5 3/6' 4,.01/2 ,)�_5 3/6" 5'_0 3/6" 5'5_3/8' 6'-0 3/6" (625) (133) (813) (927) (1051) (1232) (1356) (1534) (1661) (1838) Unobsbueted Glass 195/16" 23 9/16" '2611/16" 31 1/a" 36" 43 3/16" 48' 55 1/16" 60" 67 1/16" (491) (598) (689) (689) �(79�1) (914) (1097) (1219) (1399) (1524) (1703) �� Ln �1, ___~_{'� IBJ l ) 1 I ^iY ) `�•__ 1 AR21 AR251 AR281 AR31 AR351 AR41 AR451 AR51 AR551` AR61 W N LL? W O ED] FIM ~/\i �1 1 .�I I.ij" .,",`;� "�"-"�"•", .",."""i"'`� II_`_' -- AN21 AN251 AN281 AN31 AN351 AN41 AN451 AN51 AN551 AN61 i__ A21A251 A281 A31 A351 A41 A451 A51 A551 A61 i'y ~ � r N (D �4�J E � l� �_I\� Z �i I.� :\� I)/ / ♦i =r] AW21 AW251 AW281 AIV31 AW351 AW41 AIV451 AW51 AW5511 AW61 1-4 ® AXW281 AXW31 AXW351 AXW41 AXW451 AXW51 AXW551 AXW61 LuL'I=I --r--Ij�I----I A335 A3535 ELL,',I,,, LL� ,:' AP32V AP352V AP42V Perma -Shield®Improved/E-Z Awning Standard Window Unit Sizes Unit viewed from extenor 400 Perma-Shield®Improved/E-Z Awning Windows(1999 to Present)-7 U-S.. Canada. "z, ItFNERGY :ENERGY'; ru = NFRC.Cetffiied,,F^Andersen• Andersen <;. " - `5 i. , - °STAR` - -STAR ..� ' - 0 0 0 ,V, * ,�, v6.0 v4.1 p,Product Line 8^' Glass Y"s ;n`„Grille Type. M r Pmductsy Prodiu Type Type, aDlrectoryNumher -O O O C C ya" 22 Annealed Glass-w!No Grilles and Grilles Less Than V No Grilles AND-N-2-01430-00001- 0.28 159 ^031 053 23 40.2 - NC - Zt - Simulated Divided Lite or Installed Interior Removable AND-N-2-01430-00002 0.28 159 028 048 21 40.2 - NC - Z1 - - 3 9 Full Divided Lite AND-N-2-01448-00001 0.29 165 0.28 0.48 20 <0.2 - NC - - - - - Finelight"(grilles-0etween-the-glass) AND-N-2-01438-00001 0.28 1.59 0.28 048 21 <0.2 - NC - - P'll No Grilles AND-N-2-01431-00001 028 1.59 0.19 0.29 16 <0.2 - NC SC S Zt - Simulated Divided Lite or Installed Interior Removable AND41-2-01431-00002 0.28 1.59 0.18 027 15 <02 - NC SC S - 9 Full Divided Lite AND-t4-2-01449-00001 029 1.65 0.18 027 14 <02 - NC SC S - - Finelight-(grilles-between-the-glass) AND-N-2-01437-00001 0.28 1.59 018 0.27 15 <0.2 - NC SC S - - - No Grilles AND-N-2-01432-00001 0.27 153 021 0.48 18 40.2 NC SC S ZI11 - - E W Simulated Divided Lite or Installed Interior Removable AND-N-2-01432-00002 0.27 1.53 0.19 0.43 17 <0.2 NC SC S I Zt - 9 10 Full Divided Lite AND-N-2-01450-00001 0.28 159 0.19 0.43 16 <0.2 - NC SC S Z1 - E w, Fmelight-(grilles-between-theglass) AND-N-2-01438-00001 0,27 1.53 0.19 043 17 1.02 NC SC S Z7 - - No Grilles AND-N-2-01429-0D001 0.29 1.55 051 0.59 33 <0.2 - - - Z7 Z2 - •jai N Simulated Divided Lite or Installed interior Removable AND-N-2-01429-00002 0.29 1.65 0.47 053 31 <0.2 9 Full Divided Lite AND-N-2-01447-00001 0.29 1.65 047 053 31 <0.2 - - Z1 Z2 - 0. Finellght-(gnlles-)etween-theglass) AND41-2-01435-00001 0.29 1 B5 0.47 0 53 31 <0.2 A No Grilles AND-N-2-01531-00001 025 1.42 031 0.52 27 <0.2 [GP NC - 21 - W Simulated Divided Lite or Installed Interior Removable AND-N-2-01531-00002 075 1.42 0.28 0.47 25 40.2 - A 9= Full Divided Lite AND-N-2-01540-00001 026 148 028 OA7 24 <02 - $ Fineli MTM ) -ry _ g (grilles-between- glass) AND-N-2-01534.00001 0.25 142 0.28 0.47 25 <02 �} NC - Zt - d No Grilles AND-N-2-01532-00001 0.24 1.36 0.20 047 22 <0.2 NC I SC I S I Zt Z2 - SimulatedDividedLiteorInstalledInteriorRemovable AND-N.2-01532-0D002 024 1.30 0.19 042 21 <02 NC SC I 5 IIjZlI Z2 - E= Full Divided Lite AND-N-2-01541-00001 0.25 11,12 0.19 0.42 20 <0.2 NC SC S 1111!11 400 Series Awning N 3 " Finehght-(grilles-between-theglass) AND-N-2-01535-00001 0.24 1.36 0.19 0.42 21 <0.2 NC SC S Zt Z2 - ! No Grilles AND41-2-01530-00001 0.25 1.42 0,47 057 36 <0.2 - - - Z1 Z2 Z3 C Y w i'n Simulated DwIded Lite or Installed Interior Removable AND-N-2-01530-00002 015 1.42 0.43 052 34 <0.2 Z] Z2 Z3 z Full Divided Lite AND-N-2-01539-00001 026 1.48 0.43 052 32 <02 - - - Z1 Z2 Finelight-(gnlles-between-theglaw) AND-N-2-01533-00001 015 1.42 043 052 34 <0.2 ',{ - - - Z7 Z2 I Z3 22 Annealed Glass-w!Grilles 1"or Greater Simulated Divided Lite or Installed Interior Removable AND41-2-01430-00003 028 1.59 0.26 044 20 <0.2 NC - 21 - Full Divided Lite AND-N-2-01454-00001 028 1.59 028 0.44 20 a 0.2 - NC - -IIIZ11 - Finalight-(grilles-between4heglass) AND-N-2-01442-00001 0.29 1.65 028 048 20 <0.2 - NC - Simulated Divided Lite or Installed Interior Removable AND.N-2-01431.00003 028 1.59 0.16 0.24 14 <0.2 - NC SC S - - r' Full Divided Lite AND-11-2-01455410001 029 1.65 0.16 0.24 13 <0.2 - NC,SC S - - 9If Fmrrlight1°(gnlles-between4heglaw), AND-N-2-01443-00001 030 1.70 0.18 0.27 13 <02 - NC SC S - - ! Simulated Divided Lite or Installed Interior Removable AND-N-241432-00003 0.27 1.53 0.17 0.39 16 <02 NC SC S Zt - e � C IFull Divided Lite AND-1-2-01456-00001 0.28 1.59 0.17 0.39 15 <0.2 - NC SC S - - 3 E vi Finelight-(grilles-between-thegless) AND-N-2-01444-00001 029 1.65 019 0.43 15 402 - NC SC S - Simulated Divided Lite or Installed Interior Removable AND-N-2-01429-00003 0.29 1.65 1 0.43 0.48 29 <02 'P) - - Z7 72 w � - 3 Full Divided Lite AND-N-2-01453-00001 029 1.65 0.43 0.48 29 <0.2 S( - - Z1 Z2 - S a Finelight-(grilles-between-theglass) AND-N-2-01441-00001 0.30 1.70 0.47 053 30 <02 - - -11,Z1Z2 - z Simulated Divided Lne or Installed Interior Removable AND-N-2-01531-00003 025 1.42 0.26 0.43 24 <02 'j, NC -IIIZ1 - = Full Divided Lite AND-N-2-01543-00001 0.26 1A8 0.26 0.43 22 <0.2 'Gf NC - Finellght-(grilles between-theglass) AND-N-2-01537-00001 0.25 1.42 018 047 25 40.2 NC d Y Simulated Divided Lite or Installed Interior Removable AND-N-2-01532-00003 0.24 1 36 0.17 0.38 20 <0.2 NCSC S ZI 72 - '{ Full Divided Lite AND.N-2-01544-00001 0-25 1.42 0.17 0.38 19 <0.2 °' NC SC S Z7 - - E_ N# lemelight-(gnlles-betweendheglass) AND-N-2-01538-00001 0 25 1 42 0.19 0.42 20 <0.2 NC SC S Zl Page 8 of 155 Data assent as of Dececmber 15,2014 and is subject to change. See page 1 for more information