Loading...
HomeMy WebLinkAbout41443-Z ��o�OSUEFO[q�cpGy Town of Southold 5/3/2017 P.O.Box 1179 a 53095 Main Rd ®'y.; �ao`� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38926 Date: 5/3/2017 THIS CERTIFIES that the building GENERATOR Location of Property: 550 Greenway E, Orient SCTM#: 473889 Sec/Block/Lot: 15.-2-14 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/15/2017 pursuant to which Building Permit No. 41443 dated 3/20/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ACCESSORY GENERATOR AS APPLIED FOR The certificate is issued to Bredemeyer,Michael of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 41443 04-20-2017 PLUMBERS CERTIFICATION DATED Authorized Signa g�FEOI� TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE o . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41443 Date: 3/20/2017 Permission is hereby granted to: Bredemeyer, Michael 550 Greenway E Orient, NY 11957 To: install accessory generator as applied for. At premises located at: 550 Greenway E, Orient SCTM #473889 Sec/Block/Lot# 15.-2-14 Pursuant to application dated 3/15/2017 and approved by the Building Inspector. To expire on 9/19/2018. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO -ACCESSORY BUILDING $50.00 Total: $235.00 Builector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: L Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains fess than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"{and uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees I. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy.-'S.25 4. Updated Certificate of Occupancy-,$50.00 5. Temporary Certificate of Occupancy-Residential$I 5.00,Commercial$15.00 Date. 3/16/17 New Construction: Old or Pre-existing Building: X (check one) Location of Property: 550 Greenway East Orient NY 11957 House No. Street Hamlet Owner or Owners of Property:, Michael Bredmeyer . Suffolk County Tax Map No 1000,Section 15 . Block 2 Lot 14 Subdivision Filed Map. Lot: Permit No. T > Date of Permit. _ Applicanf:Cell Electric Health Dept.Approval: n/a Underwriters Approval: Pending Planning Board Approval: Request for: Temporary Certificate Final Certificate: X (check one) Fee Submitted:$ 235.00 (,ogmoysgreaeycree«yccen.o- Gregory C Celi Jr,���;�BCgeAh'BErCNaI�Ic.aLL Applicant Signature CONSENT TO INSPECTION MICHAEL BREDMEYER the undersigned,do(es)hereby state- Owner(s)Name(s) That the undersigned(is)(are)the owner(s)of the premises in the Town of Southold,located at-550 GREENWAY EAST.ORIENT NY 11957 which is shown and designated on the Suffolk County Tax Map as District 1000, Section ,Block ,Lot That the undersigned(has)(have)filed,or cause to be filed,an application in the Southold Town Building Inspector's Office for the following. INSTALLATION OF A GENERATOR That the undersigned do(es)hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property,including any and all buildings located thereon,to conduct such inspections as they may deem necessary with respect to the aforesaid application,including inspections to determine that said premises comply with all of the laws,ordinances,rules and regulations of the Town of Southold. The undersigned,in consenting to such inspections,do(es)so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws,ordinances,rules or regulations of the Town of Southold. Dated: -z 2 (Signatur MICHAEL BREDMEYER (Print Name) (Signature) (Print Name) pF SO�jy®l 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G Q (a Southold,NY 11971-0959 .® • �o roger.richertD-town.southold.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Bredemeyer Address: 550 Greenway East City: Orient St: New York Zip: 11957 Building Permit#: 41443 Section: 15 Block: 2 Lot: 14 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Celi Electric License No: 1022-E SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment- 11 KW Standby Generator with Automatic Transfer Switch. Notes: Inspector Signature: Date: April 20, 2017 0-Cert Electrical Compliance Form.xls DF SOUjyolo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) REMARKS: DATE / INSPECTOR FIELD INSPECTION REPORT 7 DATE COMMENTS FOUNDATION(1ST) 'y ------------------------------------ C FOUNDATION(2ND) z � 0 ROUGH FRAMING& H PLUMBING INSULATION PER N.Y-. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS G� d Q, 0 z m X � y ® p d b H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX: (631)765-9502 Survev SoutholdTown.NorthFork.net PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application h Flood Pennii Examined Single&Separate Stomi-Water Assessment Fonn fi Contact* Approved O\ 20 Mail to: Disapproved a/c Phone: aM/-, Expiration 20 Bu' ng ector D APPLICATION FOR BUILDING PERMIT D 9/22 15 gate .zo MAR 15 2017 INSTRUCTIONS a.This application MUST be completely filled to by typewriter or in ink and submitted to the Building Inspector with 4 ff l s,accurate plot plan to scale.Fee according to schedule, B� Ul*d un showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or TOWN'0MOUTHOLD c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York.and other applicable Laws,Ordinances or Regulations,for the construction of buildings.additions.or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws.ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of Yplicant or name.if a corporation) 255 RIVERHEAD RD,WESTHAMPTON BEACH NY 11978 (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder AGENT/CONTRACTOR Name of owner of premises MICHAEL BREDMEYER (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer GREGORY C.CELT JR (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No.1022E Other Trade's License No. 1. Location of land on which proposed work will be done: 550 GREENWAY EAST ORIENT,NY 11957 House Number Street Hamlet County Tax Map No. 1000 Section 15 Block Lot � _ Subdivision Filed Map No. Lot A 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy SINGLE FAMILY DWELLING b. Intended use and occupancy SAME 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work GENERATOR INSTALLATION (Description) 4. Estimated Cost 8700 Fee 235.00 (To be paid on filing this application) 5. If dwelling,number of dwelling units 1 Number of dwelling units on each floor' If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any:Front 68 Rear 68 Depth 36 Height20 - Number of Stories' Dimensions of same structure with alterations or additions: Front 68 Rear 68 Depth 36 Height20 Number of Stories1 8. Dimensions of entire new construction:Front 68 Rear 68 Depth 36 Height 20 Number of Stories' 9. Size of lot:Front 150 Rear 150 Depth 200 10.Date of Purchase 812016 Name of Former Owner NONE 11.Zone or use district in which premises are situated R-40 12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO X 13.Will lot be re-graded?YES_NOWill excess fill be removed from premises?YES_NO 14.Names of Owner of premises MICHAEL BREDMEYER Address SW GREENWAY EAST ORIENT NY Phone No. 631-208-6774 Name of Architect Address Phone No Name of Contractor GREGORY CEU JR.CELI ELECTRIC Address 255 RIVERHEAD RD Phone No. 6312882227 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?'BYES NO X *IF YES.SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO X *IF YES.D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO X *IF YES.PROVIDE A COPY. STATE OF NEW YORK) COUNTY OF being duly sworn,deposes and says that Whe is the applicant (Name of indtvt ual signing contract)abbve named. (S)Hc is the (Contractor,Agent.Corporate Officer,etc.) of said owner or owners.and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief:and that the work will be performed in the manner set forth in the application filed therewith. Swo re me t .,• r r-I ay o NotaryPublic Signature f Applica 0T$®llTyo Town Hal!Annex 9�1 Telephone(681)765-1802 54375 Main Road (631)765-85 roper riChert P.O.Box 1179 G, • �Q _ oWn.sOutholCl.ny.u$ Southold,NY 11971-0959 cOtlitilt�,� - BUILDING DR' RIVET TOWN'OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION • i REQUESTED BY: Gregory Celi Jr Date: 3/15/17 Company Name: Celi Electrical Lighting Inc. Name: License No.: 1022e Address: 2 5 5 Riverhead Rd, Westhampton Beach NY 119 78 Phone No.: '631-288-2227 Greg@celielectric.com ' I JOBSITE INFORMATION: (*Indicates required informatlon) *Name: Michael Bredmeyer *Address: 550 GREENWAY EAST, ORIENT NY 11957 *Cross Street: Main Rd *Phone No.: 631-208-6774 Permit No.: - Tax-Map District: 1000 Section: 15 Block: 2 Lot: 14 i *BRIEF DESCRIPTION OF WORK(Please Pant Cleaiiy) New 11K Generator and S/E Transfer Sw i (Please Circle All That Apply) *Is job ready for inspection: ✓ YES/ NO Rough in Final ✓ *Do-you need a Temp Certificate: YES/ NO ✓ Temp Information(if needed) *Service Size: ✓ 7 Phase 3Phase 100 150 ✓ 200 300 350 400 Other *New Service: Re-connect Underground 1,Number of Meters Change of Service Overhead Additional Information: Pf AYMENT DUE WITH APPLICATION I 82=Request for inspection Form '�� , S.C.T.M. NO. DISTRICT: 1000 SECTION: 15 BLOCK: 2 LOT(S): 14 #R10-14-0071 SEPTIC LOCATION POINT A" POINT "B" SEPTIC 10 68 LP i 37' 85' LP#2 36 74 3-4 BEDROOM SANITARY SYSTEM 1,000 GAL. SPETIC TANK (2) 8'DIAx6'DEEP LEACHING POOLS U.P� PIPE N83011 '50"E LOT 5 150.00' Cl 14.4 EL 13.7 EL 10.5 cn (6 10DRYWELL 4 ` o C) M (p ` 1 BbIAx3'OEEP va t64 S.T. fJ 60,EL 13.2 'EL 13.5 t•. PaNr"A" .21.0'• PORCH COVERED o .� ASPHALT DRIVEWAY GARAGE' GF 13.6-Q' tn 5.0' CONC. �y .0 ; 1� 'n LOT 4 1 'STY FRM. - LAND N/F - z DWELLING N OF y 41 U• FFl 16..3 GO) LATHAM F-1 CD W COVERED PORCH y W 2r 00, EL 13.4 EL 13.6 26 0' POINT"B X ® ® �rFR \ \ DRYWELL Z 8 OIAx3'DEEP a Z \ WELL li EL 12.7 PIPE EL 10.7 CL 12.7;l� a — u u u - -- I -- - - LOT 3 - - - - - - - -• •_� I w n au n v M�1,q R®�� N.Y.S. RT. 25 ZONED R-40 NON-CONFORMING LOT MAX LOT COVERAGE 20% FRONT SET BACK 40' REAR SET BACK 50' SIDE SETBACKS 75'MIN (35' TOTAL) 7HE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL FINAL SURVEY 06-16-16 LOCA77ONS SHOWN ARE FROM FIELD OBSERVA77ONS AND OR DATA OBTAINED FROM OTHERS. AREA: 20,250.00 SQ.F'T. Or 0.46 ACRES ELEVATION DATUM: ------------------------- UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYORS EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE T17LE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITU77ON LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE. THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE S7RUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE ERECTION OF FENCES, ADDITIONAL STRUCTURES OR AND OTHER IMPROVEMENTS. EASEMENTS AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF SURVEY SURVEY OF: LOT 4 CERTIFIED TO: MICHAEL BREDEMEYER; MAP OF: GREEN ACRES AT ORIENT FIDELITY NATIONAL TITLE INSURANCE SERVICES, LLC; FILED: APRIL 13, 1962 No.3540 M&T BANK; STATE OF NEW YORK MORTGAGE AGENCY; HABITAT FOR HUMANITY OF SUFFOLK HOUSING SITUATED AT: ORIENT - DEVELOPMENT FUND COMPANY, INC.; TOWN OF: SOUTHOLD KENNETH M WOYCHUK LAND SURVEYING, PLLC Professional Land Surveying and Desi SUFFOLK COUNTY, NEW YORK Y g n g P.O. Box 153 Aquebogue, New York 11931 FILE # 13-126 SCALE: 1"=30' DATE: JULY 22, 2013 PHONE (831)298-1588 FAX (631) 298-1588 N.Y.S. LISC NO. 050882 maintaining the records of Robert J. Hennessy & Kenneth M. Noychuk 6 ?16 APPROVED AS NOT DDATEB.P.# FEE: olS BY: RETAIN STORM WATER RUNOFF NOTIFY BUILDING GEPARTM AT PURSUANT TO CHAPTER 236 765-1802 8 AM TO 4 PM FOR THE OF THE TOWN CODE. FOLLOWINIG INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FC9 POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION FAUST ELECTRICAL BE COMPLETE FOR C.O. INSPECTION REQUIRED ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF S T � OCCUPANC1 USF !S UNLAWFUL WITHOUT ""ERT OF OCCUP �CY GENERAC° 8/11 hw GUARDIAN® SERIES Residential Standby Generators Air-Cooled Gas Engine INCLUDES: Standby Power Rating • True Power'' Electrical Technology Models 006237-0. 006245-0 (Steel-Bisque) -8 kW 60 Hz • Two Line LCD Multilingual Digital Models 006437-0. 006438-0,006439-0 (Steel-Bisque) - 11 kW 60 Hz Evolution'" Controller(English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: mow" 50 Amp Pre-Wired Switch or 200 Amp Smart Switch. See Page 4 for Details. �_--- • Electronic Governor • External Main Circuit Breaker, „ System Status & Maintenance GENERAC. Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Composite Mounting Pad • Natural Gas or LP Gas Operation C UI.O us • 5 Year Limited Warranty HSTED Note CUL certification only applies to unbundled units and units packaged with pre-weed switches • Capability to be installed within 18 (457 mm) Units packaged with the Smart Switch are UL certified in the USA only of a building* *Only if located away from doors,windows and fresh air intakes,and unless otherwise directed by local codes FEATURES O INNOVATIVE DESIGN&PROTOTYPE TESTING are key components O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. of GENERAC'S success in "IMPROVING POWER BY DESIGN"But It This state-of-the-art power maximizing regulation system is standard on doesn't stop there Total commitment to component testing,reliability all Generac models It provides optimized FAST RESPONSE to changing testing,environmental testing,destruction and life testing,plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by to applicable CSA,NEMA,EGSA,and other standards,allows you to electronically torque-matching the surge loads to the engine Digital choose GENERAC POWER SYSTEMS with the confidence that these voltage regulation at±1% systems will provide superior performance. O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer and sine wave form produce less than 5% Total Harmonic Distortion for network provides parts and service know-how for the entire unit,from the utility quality power This allows confident operation of sensitive electronic engine to the smallest electronic component equipment and micro-chip based appliances,such as variable speed HVAC systems O GENERAC TRANSFER SWITCHES. Long life and reliability are O TEST CRITERIA: synonymous with GENERAC POWER SYSTEMS. One reason for this PROTOTYPE TESTED v NEMA MG1-22 EVALUATION confidence is that the GENERAC product line includes its own transfer SYSTEM TORSIONAL TESTED v MOTOR STARTING ABILITY systems and controls for total system compatibility GENERAC® GENERAC® 8/11 kW features and benefits Engine co •Generac(OHVI)design Maximizes engine"breathing"for increased fuel efficiency Plateau honed cylinder walls and plasma moly rings helps the engine run cooler,reducing oil consumption resulting in longer engine life. •"Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. •Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. •Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life Now featuring up to a 2 year/200 hour oil change interval •Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil •High temperature shutdown Prevents damage due to overheating Generator •Revolving field Allows for smaller, light weight unit that operates 25%more efficiently than a revolving armature generator •Skewed stator Produces a smooth output waveform for compatibility with electronic equipment •Displaced phase excitation Maximizes motor starting capability •Automatic voltage regulation Regulates the output voltage to±1%prevents damaging voltage spikes •UL 2200 listed For your safety. Transfer Switch •Fully automatic Transfers your vital electrical loads to the energized source of power. •Pre-wired,color-coded conduits Ensures the easiest,trouble-free installation. (Pre-wired switches only) •DPM Technology Digital Power Management Technology allows for the smart control of two air conditioners without any additional (Smart Switch only) items •Remote mounting Mounts near your existing distribution panel for simple,low-cost installation EvolutionT" Controls -Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition •Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations •Utility voltage sensing Constantly monitors utility voltage,setpoints 60%dropout,80%pick-up,of standard voltage •Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. •Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. •Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds •Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute •Programmable seven day exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 12 minutes every week. •Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. •Main line circuit breaker Protects generator from overload •Electronic governor Maintains constant 60 Hz frequency Unit •SAE weather protective enclosure Sound attenuated enclosure ensures quiet operation and protection against mother nature,withstanding winds up to 150 mph Hinged key locking roof panel for security Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability •Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries -Small,compact,attractive Makes for an easy,eye appealing installation. Installation System •1 ft(305 mm)flexible fuel line connector Easy installation •Composite mounting pad GENERAC® 8/11 kW specifications Generator 006437-0,006438-0, Model 006237-0,006245-0(8 kW) 006439-0(11 kW) atetl Max tmum`GontinuousWPower Ca aci 'LP m 8'000'Wattsw 11000.Watts" lm,;: .vu..w. �,..w.�r.<.,:+e?v:xw� .."..w- Rated Maximum Continuous Power Capacity(NG) 7,000 Watts*w 10,000 Watts* �RatedVol]age,�•� �,_.�-,-.;,-�----�•;�..,_,. �-;.-_.,�.__�._.�a>,a..a.«�� 24g;. ,--T''���.�....�.., �---,---.-,,240 ���: a.,+L.wrsS ..uLa:,.:�.aoeiY..3w.aa.3'vL v w.ddWw uwLa..i..r.A.e wv(' .A �".ew.wdLm wa4:d... Rated Maximum Continuous Load Current-240 Volts(LP/NG) _ 33 3/29 2 45 8' 7 Total Harmonic Distortion.,.. ;:ti.w, . . ,.. w w . ' a: .vw....,less than5% ..;".. w.,.0 .Less than:5°h` -w. 13 oT5 Main Line Circuit Breaker 35 Amp 50 Amp Phases Number of Rotor Poles _ _ 2 _ 2 60 Hz . . <. _,4 „ .. - ., 60 tii: ,•_.� u. ,-w Power Factor 10 10 Battery,Requiremegt(pot..mcluded) ; Group,26R;r12 Volts'and 525 CCAMinimum w. »w� ."S.wuu..wtu.ws.,,....#.. ..41�•sa,•�`w...4ew„mY(.uwW�.,..w.:'.ea.,,........ .. •.,.e.wYwe o,. 1.a Unit Weight(Ib/kg) 360/163.3 407/1846 Dimensions jL x We H))iNmm. 'a , , _ w 48 x25;x 29/1218 x 638 x Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load** 62 63 Engine GENE, OtiVf ;" n 'GENERAL OHVI VrTW1N �;.„�., �.cu»e,�,..,ad',+.,�u:..>m. a,...,sw.:,aa...,.,..:,:'.LC,,,. ....rc ww.. •.,a,a,v.... .. Number of Cylinders 1 2 Displace a t' _m 10530"cc Cylinder Block Aluminum w/Cast Iron Sleeve Aluminum w/Cast Iron Sleeve — - Wim.,. _.. ,r _. Valve Arrangement`u,„ ,,; Oyerheatl.Valve v rh d:"Valy ' •, �b.w, .,� . .:0 e ga a wW>w Ignition System Solid-slate w/Magneto Solid-state w/Magneto) overeorSystefn , . ..W ... .,..W..",,..... �u.,.. ww..ww. -„..W .„.. .. `Electrorncx. .% ,w .*. . :... Electronic . .,,.. ,” 7 1 Compression Ratio _ 951 9 51 :Starters '.w. 12Udc . ate. . •� ..W 12;Vdc u ..,« .aaw...,,,�,...,,ee.,.•�:.�,.:a..,:,..v.+.,tt,aa,".. ,,,m.:+r,. .;a+..,....w .eu,.,d..,.. �.mw,...m .o:,w,.s« Oil Capacity Including Filter Approx.)5 gV1N4 L Approx 17 qt/1 6 Ln 0 grotto _rPm �, ..� _ ...:•3;.600.,. , 3,600:'" .,. Fuel Consumption Natural Gas fts/hr(m3/hr) 1/2 Load 78(2 21) 124(3 51) Full Load 121 (3 43) 195(5.52) Liquid Propane ft3/hr(gal/hr)[I/hr] 1/2 Load 31 6(0 87)[3 29] 42 8(1 18)[4.45] Full Load 51 6(1 42)15 37] 70(1 92)[7 28] Note:Fuel'pipe must be sized}or"full toad. gu(red fuet pressure to'generatar fuel.;inlet at all,load ranges-,3,5-71, column(7=13smm mercury)for,naturaLgas,10=12":water column(19=22 mm', ' meercury)`9[,LP gas Forigtu content,multiply ft3/hrx 2500(LP)orft3/hr x 1000(NG),aFor Megajoule;convent,'multrply m3lhr x 9315.{CP}or m3/hr x 37.26(NG) Controls 2 Lme PlainText Multilin ual(LCD>D a' " ' 9 �sp.Y W�_ w {W Sample userinterface toy ease.of operation:ww,.., ..s..... .�9 .,� Mode Buttons Auto Automatic Start on Utility failure 7 day-exerciser �,> ; nti , �,.,.,,�7 , atm..--..."F..-� m T „ m a Manual ". . •° '' ' StaStwithstarterwcontrol,unitffstays'on.„„•Ifdlity•fails,transfer,toloadutakes,place,, w ''J..b.±..�W..w..ixm..,.w,.. a,,,.,..Y•,.,,..awww,aa,:.1.L.w.a.m:.L,wtW..�a,.ua.,.v..w.L..,a..,nw,,....w.x..............t.«....u.noa..w.�L...., Off _ Stops unit Power is removed Control and charger still operate _ Ready.tdRur��Mamferiance(yiessages: ..�.w.e.•.,�.�-..»„.......�.�..�.,,.��,.. ..,•w ..�,.-..»�� �..><...� � ,�,...�.,�K '�,�.....,�.,.._,.��,..�..,,,.� Engine Run Hours Indication Standards Programmaale start tlefay.,,betiyeen22 150b.secondsp v-.�°` LL rt __ Staritlard(prograrnmable by deafer onl�) v” �rm ,. _ UttlityVoltage Loss/Return to Utility Adjustable From 140-171 V/190-216 V _ Fyture,Sei Capablg Exetciser/Exe.cise„Set,Errgr Wamin9 G, µ .. •, u w S d . ,z. tan card, :a .. Run/Alarm/Maintenance Logs 50 Events Each E gine Start Se uen e; 7 T _ n g c w.,„_ ,- „ 4,� „„ ;r .,R*•, ,,, „„,„ � a �y0ycliperankingµ,l6 sgc:oon,7rest,(90'sec.rmatiimum'duration}r . ,.; Starter Lack-out Starter cannot re-engage until 5 sec after engine has stopped _ Smait 9attery Charger m Stadaru Wn 7-7777-7 Charger Fault/Missing AC Warning Standard _ ^^!�., P.- . ,Y�.r”E"w+.^•..q-nrc,.rn?.."+.ym-.a.a„ m.:N n°-r„'T.w-".,- Y•,."-.,..�.-""'..,�,." , Low Battery/BatterywProb(ern> Protection and.Baitery Condiiio_Indtcafion ;,, '„„„,,,y • �w _• W„ „ Standard "mmiYw - Automatic Voltage Regulation with Over and Under Voltage Protection Standard _ Under-Frequency%Werload(Stgpper Overcurrent Protechori', ., y _ rStandard;^`� ', w” w yw Safety Fused/Fuse Problem Protection Standard Autamati,6 o%.Oif Pressure/H[gh Oil Temperature Shutdowns Stantlardi w 4 Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard High ErgtnaTemphtuigS utdownv Internal Fault/Incorrect Wiring Protection_ _ _ Standard Comm EeternalFaultCapability w•Y.:. : 'Standards Field Upgradable Firmware Standard **Sound levels are taken from the front of the generator Sound levels taken from other sides of the generator may be higher depending on installation parameters Rating definitions-Standby Applicable for supplying emergency power forthe duration of the utility power outage No overload capability is available for this rating (All ratings in accordance with BS5514,IS03046 and DIN6271) *Maximum wattage and current are subject to and limited by such factors as fuel Btu/megajoule content,ambient temperature,altitude,engine power and condition,etc Maximum power decreases about 3 5 percent for each 1,000 feet(304 8 meters)above sea level,and also will decrease about 1 percent for each 6°C(10°F)above 16°C(60°F) v GENERAC® 8/11 kW switch options Pre-Wired Switch Features Model 006237-0(8 kW) 006437-0(11 kW) Electrically operated,mechanically-held contacts No of PPoles ,. '� ?' for fast,positive connections Current Rating(Amps)s X50 50 ( _... — n' VpiRaUn9NtaeAC�... '. �... , -..�250 • Rated for all classes of load,100%equipment Utility Voltage Monitor(Fixed)* ..µ rated,both Inductive and resistive -Pick-up 80% 80% 2 pole,250 VAC contactors Dropout 60% so% Return to°t)liltyy " , .* 7-7 'approxi 15 sec ;, approx 15 sec,,, w • 30 millisecond transfer time Exerciser weekly for 12 minutes* Standard Standard • Single coil design UL$ed Standard °m Total of Pre-wired Circuits 10 12 • Main contacts are silver plated or silver alloy to No 15 A 120 V 3 5 resist welding and sticking No.20 A 120 V 3 3 No 20 A 240 V 1 - - NEMA 1 (Indoor rated)enclosure is standard on No 30 A 240 V 1 1 the pre-wired switch No 40 A 240 V - 1 No 50 A 240V - - - Pre-wired 30 foot 9.1 meter whip connect t to �• � ,„ - R = s•, ° CircuitBreaker Protected' �" „ the provided 5 foot re-wired whip and external AVailable`RMS Symmetrical', connection box FaultCurrenttl@P5oVo , Its 0000 � „ • Pre-wired 2 foot(0 61 meter)whip,color coded to *Function of Evolution Controller connect into the existing electrical panel Dimensions Mechanical Dimensions =0 Height Width Depth H1 H2 H3 W1 W2 W3 g� , in185 225 22 105 154 144 38H2 mm 470 1 5718 5588 266.7 392 1 366 975 Note The 50 amp switch is flush mountable H1 and W1 refer to mounting hole spacing H2 and W2 are cover dimensions H3 and W3 are the enclosure dimensions without cover Wi Wire Ranges W2 Conductor Lug Neutral Lug Ground Lug 50 Amp Switch 1/0-#14 2/0-#14 2/0-#14 Smart Switch Features Model 006438-0(11 kW) available on 11 kW model only [Nop of�Poles�, .F.o��..�-��.w�. .' ,�..2a- �,:.„�.;.,•��. ...: • Includes Digital Power Management Technology standard(DPM) Current Rating(Amps) 200' Voltage Rating(VAC)„ ___ - " 250 • Intelligently manages two air conditioner loads with no additional hardware Utility Voltage Monitor(Fixed)* • Up to four more large(120/240 VAC)loads can be managed when used in -Pick-up 80% conjunction with Power Management Modules(PMM) lity Dropout so% Retarrtlo Uti :;., .;; 'm;° M �approx;l3 • Electrically operated,mechanically-held contacts for fast,clean connections Exercise weekly for 12 minutes* Standard • Rated for all classes of load,100%equipment rated,both Inductive and resistive uL Listed ° . Standard Enclosure Type NEMA/UL 3R Am`s ° , • Service equipment rated,dual coil design Wthstand Ratin9_( p.)" _ Lug Range _-250 MCM-#6 • Rated for both aluminum and copper conductors *Function of Evolution Controller • NEMA/UL 3R aluminum outdoor enclosure. -W1 • Main contacts are silver plated or silver alloy to resist welding and sticking Dimensions 200 Amps 120/240,1e Open Transition Service Rated HeightWidth H2 H1 H1 H2 W1 W2 Depth in 27.24 1 30 0 114 135 709 Prim 692 0 762 4 2890 3430 1800 -DEPTH"- W2 GENERAC® 8/11 kW available accessories Model# Product Description 005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system Generac offers the recommended co 26R wet cell battery for use with all air-cooled standby product. If the temperature regularly falls below 32°F(0°C),install a cold weather Idt to maintain optimal 006212-0 Cold Weather Kit battery and oil temperatures.Kit consists of a battery warmer and oil filter heater with built-in thermostats. 005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electri- Contact Kit cal load you may not need.Not compatible with 50 amp pre-wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators.This 005839-0 Fascia Base Wrap Kit offers a sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located In the base. If the generator enclosure is scratched or damaged,it is important to touch-up the paint to protect 005703-0 Paint Kit from future corrosion.The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. 006482-0-8 kW Generac's scheduled maintenance kits provide all the hardware necessary to perform complete 006483-0-11 kW Scheduled Maintenance Kit routine maintenance on a Generac automatic standby generator. Completely wireless and battery powered,Generac's wireless remote monitor provides you with 005928-0 Wireless Remote instant status information without ever leaving the house.Not compatible with CorePower or EcoGen systems. The PMM Starter Kit consists of a 24 VAC,field installed transformer that enables the use of the 006199-0 PMM Starter Kit 24 VAC Power Management Modules(PMMs)and one PMM.The standard controller(without starter kit)can control two HVAC loads with no additional hardware.Not compatible with pre-wired switches. Power Management Modules are used in conjunction with the Smart Switch to increase its power 006186-0 Power Management Module(50 management capabilities.It gives the Smart Switch additional power management flexibility not Amps) found in any other transfer switch.Not compatible with pre-wired switches.Note:PMM starter kit required. Generac's Mobile Link allows you to check the status of your generator from anywhere that you 006463-1 Mobile Link" have access to an Internet connection from a PC or with any smart device.You will even be notified when a change in the generator's status occurs via e-mail or text message. dimensions & UPCs Dimensions shown are approximate. Refer to installation manual for exact dimensions DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. 637 6 mm [251 in] [47. mm [47.91n] Model UPC 006245-0 696471062458 o " 006237-0 696471062373 006439-0 696471064391 731 9 mm [28 in] 006437-0 696471064377 006438-0 696471064384 0 JAI0 0 642 mm [25 3 in] 1226 mm [48 31n] LEFT SIDE VIEW FRONT VIEW GENERAC' Generac Power Systems,Inc. • S45 W29290 HWY.59, Waukesha,WI 53189 • generac.com ©2013 Generac Power Systems,Inc All rights reserved All specifications are subject to change wthout notice Bulletin 0197980SBY-G Printed in U S A 12/06/13