HomeMy WebLinkAbout41503-Z �og�FF01 Ort Town of Southold 4/10/2023
X4'0 y�
P.O.Box 1179
o • am53095 Main Rd
Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 38894 Date: 4/7/2017
THIS CERTIFIES that the building ALTERATION
Location of Property: 7785 Horton Ln, Southold
SCTM#: 473889 Sec/Block/Lot: 54.-5-49.3
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
4/6/2017 pursuant to which Building Permit No. 41503 dated 4/6/2017
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
"as built"window replacement and furnace installation in an existing one family dwelling as applied for.
The certificate is issued to Santacroce,Henry&Ellen
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO.
PLUMBERS CERTIFICATION DATED
U. A ho iz ignature
o�gU o4ca TOWN OF SOUTHOLD
�a BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
o • SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 41503 Date: 4/6/2017
Permission is hereby granted to:
Santacroce, Henry & Ellen
2520 Pine Tree Rd
Cutchogue, NY 11935
To: as built" window replacement and furnace installation in an existing one family
dwelling as applied for.
At premises located at:
7785 Horton Ln, Southold
SCTM # 473889
Sec/Block/Lot# 54.-5-49.3
Pursuant to application dated 4/6/2017 and approved by the Building Inspector.
To expire on 10/6/2018.
Fees:
SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $200.00
CO -NEW DWELLING $50.00
Total: $250.00
UdinInspector
Form No_6
TOWN Of SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or
topographic features.
2. Final Approval from Health Dept.of water supply and sewerage-disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains Iess than 2/10 of 1%lead.
5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and"pre-existing"land uses:
1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is
denied,the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. , Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00,
Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00.
2. Certificate of Occupancy on Pre-existing Building- $100.00
3. Copy of Certificate of Occupancy-$.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00
Date.
New Construction: [[Old or Pre-existing Building:
.,� (check one)60
Location of Property: �J � k-q "�n
House No. Street Hamlet
Owner or Owners of Property: I
Suffolk County Tax Map No 1000, Section L4 Block Lot
Subdivision �} l Filed Map. Lot:
Permit No. 1 I lj� Date of Permit. Applicant: ,
Health Dept.Approval: Underwriters Approval:
Planning Board Approval:
Request for: Temporary Certificate Final Certificate: (check one)
Fee Submitted:$
f
Pa i nature
so
Town Hall Annex Telephone(631)765-1802
54375 Main Road Fax(631)765-9502
P.O.Box 1179
Southold,NY 11971-0959
BUELDING DEPARTMENT DD
TOWN OF SOUTHOLD
APR - 7 2017
PrJMDING DEPT.
TOSOOr' SOUTH-O'.i D
CERTIFICATION
Date:
Building Permit No.
Owner: /7
(Please print)
Plumber:
(Please print)
I certify that the solder used in the water supply system contains less than 2/10 of 1%
lead.
(Plumbers Signature)
4-h
Sworn to before me this CD
day of r- I 20
814ARON L.'I`UTOLL
Notary Public,Stata_of New York
No.Oik x.uti-o k477 t
Qualified In Stairt�lk County
Commission Expires May 20,20i IS
Notary Public, `j u4a 1� County
V �"OE SOUIyo
H 0
holy 0 N1V,��
-TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
-INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLEIG.
[ ] FOUNDATION 2ND [ ] SULATION
[ ] FRAMING / STRAPPING [ FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
REMARKS: F 4 l 590<z. , (>V-
jtC,tAz� 'EvY ,ice, h Q
if
oK
DATE INSPECTOR
TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following,before applying?
TOWN HALL Board of Health
SOUTHOLD, NY 11971 4 sets of Building Plans
TEL: (631) 765-1802 Planning Board approval
FAX: 631 765-9502 Survey
SoutholdTown.NorthFork.net PERMIT NO. Check
Septic Form
N.Y.S.O.E.C.
Trustees
C.O.Application
Flood Permit
Examined4) //) 20j_j _ Single&Separate
Storm-Water Assessment Form
_ Contact:
Approved ,20 Mail to: S?
Disapproved a/c
Phone: l ZX�x X0
Expiration U 7 ,20 16 '
D GCS
D i spector
APR ® R 2017 APPLICATION FOR BUILDING PERMIT
BUILDING DEM Date ^�� � , 20
TOWN OF SOU'1110LO INSTRUCTIONS
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, accurate plot plan to scale.Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application,'the Building Inspector will issue.a Building Permit to the"applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied br used in whole or in part for any 11 1purpose what so ever until the Building Inspector
issues a Certificate of Occupancy. - "'
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been complefed within 18 months from such date.If no zoning amendments or other regulations affecting the
property have been enacted in the interim,the Building.Inspector may authorize, in writing,the extension of the permit for an
addition six months. Thereafter,a�new'permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southpld,.Suffolk.County,New York, and other applicable Laws, Ordinances or
Regulations, for the construction of building's,additions,or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws;'ordinances,building code,housing code,and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections.
(Si a r of applicant or name,if a corporation)
(Mailing address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Name of owner of premises - `77J9C rP41-r C-4�'v4 Z
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No.
t l. Locatiorrtof land on,•which proposed work will be done:
.House-Number,::,' A' ;`' Street Hamlet
4
County Tax Map No. 1000 Section Block Lot �(
Subdivision ; Filed Map No. Lot
i
2. State existing use and occupancy of premises and intended use and occupancy of proposed 'construction:
a. Existing use-and occupancy
b. Intended use and occupancy
3. Nature of work(check which applicable);NeW Building Al eration
Repair Removal Demolition then Work 6(/. �,
(Description)
4. Estimated Cost Fee
(To be paid on,filing this application)
5. If dwelling, number of dwelling units Number of dwelling units on each floor
If garage, number.of cars
,6.1 If business, commercial or mixed occupancy, specify nature and-extent of each type of use.
7. Dimensions of existing structures, if any:!Front Rear Depth
Height Number Eof Stories
Dimensions of same structure with alterations.or additions: Front Rear ';a
Depth Height Number of-Stori'es
8. Dimensions of entire new construction: Front'' '` Rear Depth
Height Number of Stories
9. Size of lot: Front Rear Depth
N. Date of Purchase Name,of Former Owner '
1 . Zone or use district in which premises are,situated
12. Does proposed construction violate any;zonirig l4.y, ordiga ce•orregulation?YES NO
l". Will lot be re=graded;? YES NO ill e;�eess fitl-b,e removed from premises? YES NO
14. Names of Owner of premises ,. Address Phone,•No.
Name of Architect r' s Address Phone No
Name of Contractor ' Address-_ i .,Phone.No,.
1 a. Is this property within'100 feet of a'tidal Wetland"or"a'fresliwatbr wetland? *YES ' NO,
IF YES, SOUTHOLD',TOVN TRUSTEE,,:&'"D61"C.,PERMITS'MAY BEREQUIRED.
b. Is this property wit in'300 feet of a tidal'we!tjarid?'*"'YES,' NO
IF YES, D.E.C. PERMITS MAY BE REQ,UI 20'."
16). Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 1,10 feet or below, must provide topographical data on survey.
1 . Are there any covenants and restrictions With respect to this property? * YES NO
IF YES, PROVIDE A COPY.
S ATE OF NEW YORK)
SS:
COUNTY O
vie", b6ing'duly sworn, deposes and says that(s)he is the applicant
ame of i ividual signing contract) above named,
(S)He is the
(Contractor,Age�'it, Corporate Officer,etc.)
i
!
of said owner or owners,and is duly authorized to'perform or have performed the said work and to make and filethis application;
th t all statements contained in this application are,true to the best of his knowledge and-belief; and thst the work will be
performed in the manner set forth in the applicatign filed therewith. TRACEY L. DWYER
NOTARY PUBLIC,STATE OF NEW YORK
Sworn to before me this INO.01DW6306900
f _ day of 20-7 ! QUALIFIED IN SUFFOLK COUNTY
COMMISSION EXPIRES JUNE 30,
tary PublicSi 0 ture of Applicant)
i
a
WINDOWS-DOORS
Andersen® . -
4.0 0 SE R
lin •
AWNING WINDOWS
Built on the same platform as our legendary casement
window, 400 Series awning windows deliver the same
performance and beauty. Their solid wood frames and sash
provide strength, while the vinyl covering and weather-tight
'c`.w construction keep the window and your home protected
from the elements. On the inside you have the choice of
til_c
natural pine or clow-maintenance white, dark bronze or
black*finish. For added style there is a wide range of grille,
hardware and art glass options.
DURABLE
J • Virtually maintenance-free
• Perma-Shield®exteriors never need painting and won't peel, blister,
flake or corrode"
<,
• Frame exterior is protected by a tough vinyl cover that resists dents and
repels water and provides long-lasting protection
• Available with Stormwatch®protection for coastal areas
--- - __ ENERGY EFFICIENT
• Weather-resistant construction for greater
1 I comfort and energy efficiency e
h • Weatherstripping is designed to seal out
drafts,wind and water
• Variety of Low-E4®glass options are available to help control heating and
.y cooling costs in any climate
` } ,
,' fr • Many 400 Series awning windows have options that makes them
rel ! ENERGY STAR®v.6.0 certified throughout'the U.S.
+ (�• BEAUTIFUL
.y
• Seven exterior color options
• Natural pine,white,dark bronze or black' Interiors
` • Extensive hardware selection
P • Add style with grilles,exterior trim,art glass or patterned glass
EXTERIOR COLORS
AIR 7 2017 White Canvas Sandtone Terratone Forest Green Dark Bronze Black
BUILDWG DEPT.
TOWN�7® ��®}r7rp,,g{T�7� 'Dark Bronze and Black interiors are only available with Dark Bronze and Black exteriors respectively
VP 1� S �V 9.5 0 D See your Andersen dealer for availability**Vsit andersenwmdows comA arranty for details
CUSTOM SIZES "ENERGY STAR"is a registered trademark of the U S Environmental Protection Agency
1 r
.•i,;,:.i.t��1eF „ .. a a '''�_ a+ - J 1`�' 'i �_ 1 'F`' 6a'�'h ,�'J 1,�,
• j.,`r �.�Ati� �,.,,u$'."`.� � s'G a _y F'�"-- .«s�fJ .'- inti,, .1'`, qw+'-T,� `��Ir.�+ � G rR'_ tti sl Y a,���r�1�4 f a`y�'��'A
`®'�® - /- ii F, `;vF,-,7 '€ rat 4 'Y�a"�• -i+y
-
4'
GLASS OPTIONS INTERIOR OPTIONS
• Low-E4®glass
• Low-E4 glass with HeatLock®technology
• Low-E4 Sun glass
• Low-E4 SmartSun-glass Pine White Dark Bronze' Black'
• Low-E4 SmartSun glass with HeatLock technology Naturally occurring variations in grain,color and texture of wood make each window one-of-a-kind.
Additional glass options are available.Contact your All wood interiors are unfinished unless prefinished White,Dark Bronze or Black is specified
Andersen dealer.
HARDWARE FINISHES
ART GLASS r—;
A wide range of art glass patterns, including Frank Lloyd i
Wright®series designs are available to add beauty to
your home. Antique Brass Black Bright Brass Brushed Distressed Distressed
Chrome Bronze Nickel
PATTERNED GLASS
Available In four attractive patterns ideal for letting light I �i
Into the home while obscuring vision.
Gold Dust Oil Rubbed Polished Satin Nickel Stone White
tP, ;,lf.
•�.r•'Irl, „ Ir{ �`, Bronze Chrome
Distressed bronze and oil rubbed bronze are"living"finishes that will change with time and use.
HARDWARE
Obscure Cascade^ Reed Fern A CLASSIC SERIES" ESTATE"
EXTERIOR TRIM a "
Available In 11 colors to l
complement your exterior.
Stone I White ,_ Antique Brass I Bright Brass
Brushed Chrome I Distressed Bronze
Distressed Nickel I Oil Rubbed Bronze
Polished Chrome I Satin Nickel
7 ,
TRADITIONAL FOLDING CONTEMPORARY FOLDING
GRILLES
rte. ,v, _
Choose from dozens
of popular designs or
work with Andersen to Antique Brass I Black I Bright Brass nBlack I Bright Brass
create custom patterns 19H] IF21Distressed Bronze I Distressed Nickel I Gold Dust I Oil Rubbed Bronze
Gold Dust I Oil Rubbed Bronze I Satin Nickel Satin Nickel I Stone I White
Stone I White
'Dark Bronze and Black interiors are only available with Dark Bronze and Black exteriors
WINDOWS-DOORS
respectively See your Andersen dealer for availability LqjVA
Printing limitations prevent exact color and finish duplication See your Andersen dealer for Andersen.
actual finish samples
"Frank Lloyd Wright"is a registered trademark of the Frank Lloyd Wright Foundation
"Andersen"and all other marks where denoted are trademarks of Andersen Corporation
02016 Andersen Corporation All rights reserved SS_01607/16 For more information, visit andersenwindows.com/400series
For help finding an Andersen product or dealer near you, please call
us at 877.577.7655 or visit andersenwindows.com.
z�
ANDERSEN®400 SERIES WINDOW AND DOOR NFRC/ENERGY STAR®INFORMATION
This document provides NFRC certified U-Factor,Solar Heat Gain Coefficient(SHGC)and Visible Transmittance(VT)values for Andersen®products along
with the corresponding ENERGY STAR)Version 6.0(2015)climate zones in which the product and glass type are certified.
These products rated,certified and labeled y National Fenestration Rating Council® (NFRC)-a non-profit organization that provides fair,
accurate and credible energy performance ratings for windows and doors.
Many of our products meet the stringent energy efficiency certification criteria set by the U S.Environmental Protection
Agency and the U.S.Department of Energy. The certification criteria is based on the heat gain and loss of each product In
various regions of the country. Check the Andersen product performance available at www.andersenwindows.com for units
that are ENERGY STAR certified.
United States ENERGY STAR® Canada ENERY STAR®
Climate Zone Criteria Climate Zone Criteria
eS ENERGY STAR®
® Northern �` � ❑ ZONE 3
' �,
rr ` N ® ZONE 2
❑ North-Central ❑ ZONE 1
�• ,
^g South-Central r` `
® .,.` 6u
17
Southern
Windows
Doors / ..�:-=41 m
Zone
U.
,Factor' .SHGC2 Glazing U-Factor' SHGC2 - '
Level
s 027 Any Prescriptive s 017'' No Rating
=028 a032:',, 5025 5025
i' EquiJalent Northern .o
ors
=029'` 2037' North-Central 5040
Performance 5030 (e I ffective February 1, 15)
Southern
=030 2042 South-Central i 5025 n r
Air Leakage for Sliding Doors!9 0 3 cfmfft1
Nath- f 5030 x040 Air Leakage for Swinging Doors505cfmR?
Central
5(130 50 25 aas6o ;f _ zs �6oru{ 1.60
._..26000_.,�f.�,.-,y._.._.^.34._....._�..�I._or `� 1.20`_.
5040 50 25
Pur Leakages 0 3 cfmRt2 P ai
'Btulh R'.F
'Solar Heat Gain Coefficient
"The effective date for the Northern Zone prescriptive
and equivalent energy performance criteria for vNndovs
i s January1,2016
For NFRC certified total unit performance for units with capillary breather tubes,please refer to the High Altittude information section for each unit
'U-Factor defines the amount of heat loss through the total unit in BTU/hr"ft 2'-F,metric in W/m2•K The lower the value,the less the heat is lost through the entire product I
2Solar Heat Gain Coefficient(SHGC defines the fraction of solar radiation admitted through the glass both directly transmitted and absorbed and subsequently released inward The lower the value,the less heat is transmitted
through the product
3Visible Transmittance(VT)measures how much light comes through a product(glass and frame) The higher the value,from 0 to 1,the more daylight the product lets in over the product's total unit area Visible Transmittance
Is measured over the 380 to 760 nanometer portion of the solar spectrum
NFRC ratings are based on modeling by a third party agency as validated by an independent test lab in compliance with NFRC rpogram and procedural requirements
This data is accurate as of December 15,2014 Due to ongoing product changes,updated test results or new industry standards or requirements,this data may changeover time Due to variations in dealer and distributor
inventory levels,products that were manufactured before December 15,2014 that were designed,tested and labeled with different NFRC values may still be available Check the labels on the product packaging to confirm NFRC
values Ratings are for sizes specified by NFRC for testing and certification Ratings may vary depending on use of tempered glass,different grille options,glass for high altitude,etc
All marks where denoted are trademarks of their respective owners
O 2014 Andersen Corporation All rights reserved
U.S.' Canada
•'
'ENERGY ENERGY,
Andersen• Andersen , - NFRC Certified - o _ o u W STAR
o STAR •
Product Line& Glass Grille Type - Products m m C 9 v OA . v 4.1
Product Type Type - - ,, Directory Number w 7 m a w m-
�Z
Z N N N N
2.2 Annealed Glass-w/No Grilles and Grilles Less Than 1'i
No Grilles AN0.N-2-01430-00001 028 159 0.31 0.53 23 <02 - NC - Zt
Simulated Divided Lite or Installed Interior Removable AN0.N-2-01430-00002 0.28 1.59 028 048 21 <112 NC Zt
Full Divided Lite AND•N•2-01448.00001 029 165 028 048 20 <112
FInellghtTM(grilles•between-the glass) AND•N•241436-00001 028 1.59 028 048 21 <02 - NC - - Z1 -
No Grilles AND-N-2-01431-00001 028 159 019 029 16 <02 - NC SCI ,S Zt
w c Simulated Divided Lite or Installed Interior Removable AND-N-2-01431-00002 028 1.59 018 027 15 <0.2 - NC SC - -
cFull Divided Lite AND-N-2-01449-00001 0.29 165 018 0 271 14 <02 - NC SC FS
Flnelight"(gnlles-between-the-glass) AND-N-2-01437-00001 0.28 1.59 0.18 027 15 <02 - NC SC �S
No Grilles AND-N-2-01432-00001 027 153 021 048 18 <02 NC Sc 71 - -
W Simulated Divided Lite or Installed Interior Removable AND-N-2-01432-00002 027 153 019 043 17
<02 NC SC ��S Z1
4'h -
Full Divided Lite AND-N-2-01450-00001 028 159 019 043 16 <02 - NC SC S Z1
FinellghtTM(grilles•between-theylass) AND-N-2-01438-00001 0,27 1.53 019 043 17 <02 NC SC kS Z1
No Grilles AND-N-2-01429-00001 029 165 051 059 33 <0.2 -
c
ieiai in Simulated Divided Lite or Installed Interior Removable AN0.N-2-01429-00002 029 1.65 047 0.53 31 <02 Z7 Z2
, m
Full Divided Lite AND-N-2-01447-00001 029 1.65 047 0.53 31 <02 - - Z1 Z2
A.
Finelight*Y(grilles-between-the-glass) AND•N-2-01435-00001 029 1.65 0.47 0.53 31 <02 - Z1 Z2
! No Grilles AND-N-2-01531-00001 025 1.42 031 052 27 <02 NC - - Zl
it o Simulated Divided Lite or Installed Interior Removable AND-N-2-01531-00002 025 1.42 028 0,47 25 <02 NC - Zi - -
o °
= Full Divided Lite AND•N•2-01540-00001 026 148 028 047 24 <0.2 NC - Z1
3
FInellghtTM(grilles-between-the-glass) AND-N-2-0153400001 025 1 142 1 028 047 25 <02 NC - - Zt -
! No Grilles AN0.N.2-01532-00001 024 1.36 020 047 22 <02 NC SC FS, Zt Z2 -
ioivi c.� Simulated Divided Lite or Installed Interior Removable AND-N.2-01532.00002 024 1.36 019 0.42 21 <02 NC SC e1'S' Z1 Z2
11
E= Full Divided Lite AND-N-2-015411-00001 025 142 019 042 20 <02 NC SCS, Zi
400 Series Awning y 3s
Fmelight"'(gnlles-between-the-glass) AND-N-2-01535-00001 024 136 019 042 21 <02 NC Sc NS Z7 22 -
e 7 No Grilles AND-N-2-01530-00001 025 142 047 057 36 <02 Zl Z2 Z3
c"
�o Simulated Divided Lite or Installed Interior Removable AND•N-2-01530-00002 025 142 043 0 52 34 <III Z1 Z2 Z3
3 v
�m n x Full Divided Lite AND-N-2-01539-00001 026 148 043 052 32 <0.2 - - Z7 Z2
A.3
FInellghtTM(grilles-between-the-glass) AND-N-2-01533-00001 025 142 043 0.52 34 <0.2 ZI Z2 Z3
2.2 Annealed Glass-wl Grilles 1"or Greater
Simulated Divided Lite or Installed Interior Removable AN0.N-2-01430-00003 028 159 0.26 0.44 20 <112 - NC - - Z1 - 11
-
'a
3 Full Divided Lite AND-N-2-01454-00001 028 159 026 044 20 -02 - NC - Z1 -
0
J Flnelight^(grilles-between•the-glass) AND-N-2-01442-00001 029 165 028 048 20 <02 - NC - - - -
Simulated Divided Lite or Installed Interior Removable AND-N-2-01431-00003 028 159 016 024 14 <112 - NC SC vS - - -
e
a
3
vi Full Divided Lite AND-N-2-01455-00001 029 165 016 024 13 <0.2 NC SC (S - -
0
J FInellghtTM(gnlles-betweendheylass) AND-N-2-01443-00001 030 170 018 0.27 13 <0.2 - NC SC
Simulated Divided Lite or Installed Interior Removable AND•N•2-01432-00003 027 153 017 039 16 <0.2 NC Sc S Z1
°a c -
3 C Full Divided Lite AN0.N-2-0145640001 028 159 017 039 15 <02 NC SC 5
sE
vt FInellghtTM(grilles-helween-theylass) AN0.N-2-0144400001 029 165 019 043 15 <02 - NC SC
e Simulated Divided Lite or Installed Interior Removable AND-N•2-01429-00003 0.29 1.65 043 048 29 <0 2 - Zi Z2 -
® c
w �
3 Full Divided Lite AND•N•2-01453-00001 029 165 043 048 29 <0.2 21 Z2 -
J v, ,
m FinellghtTM(gnlles-between-theylass) AND.N-2-01441-00001 030 1.70 047 053 30 <02 - Z1 72
.rye Simulated Divided Lite or Installed Interior Removable AND-N-2-01531-00003 025 142 026 0.43 24 <0 2 NC Z1
w 0
ju Full Divided Lite AND-N-2-01643-00001 026 148 026 043 22 <0.2 NC - Z1 -
x
3 FlnelightTM(grillesbetween-theylass) AND-N-2-01537-00001 025 1.42 0.28 047 25 <02 NC Zt
°a cs Simulated Divided Lite or Installed Interior Removable AND•N-2-01532-00003 024 136 017 038 20 <0 2 NC SC t5 Zt Z2
e
3 m Full Divided Lite AN0.N-2-01544-00001 025 1.42 017 038 19 <0 2 NC SC -
o
w Flnelight^(gnllesbetween4heylass) AND-N-2-01538-00001 025 142 019 042 20 <02 NC Sc
Page 8 of 155 Data count as of Dececmber 15,2014 and is subject to change
See page 1 for more mf-hon
U.S.
, •Canada
+r ENERGY' ENERGY
'STAR 'STAR
"Andersen! Andersen NF
' - - RCCerbfied oy o o ,� �, v0.0 -,v4.1
• ProduetLloe&' Glass • - - GdOeType-" -_ ',t 'Products
Product Type TYPe, -, ., Directory Number
2rC1 i'Q W
® �e Simulated Divided Lite or Installed Interior Removable AND-N-2-01530-00003 025 142 039LOO 31 <02 NCFull Divided Lite AND-N-2-01542-00001 026 148 039 30 <0 2 NCFlnelightTM(grilles•between-the-glass) AND-N•2-01536-00001 026 148 043 32 <02 Z1 Z2
3.0 Annealed or 3.1 Tempered Glass-w/No Grilles and Grilles Less Than V
No Grilles AND-N-2-01460.00001 029 165 031 0.53 22 <02 - NC - - - -
ev Simulated Divided Lite or Installed Interior Removable AND-N-2-01460-00002 029 165 028 048 20 402 - NC - -
oFull Divided Lite AND-N-2-01472-00001 029 165 028 0.48 20 402 NC - - -
Firelight-(grilles.between•the-glass) AND-N•2-01466-00001 029 1.65 028 048 20 <02 NC
No Grilles AND-N•2-01461-00001 029 165 019 029 15 <02 - NC SC 'S
e simulated Divided Lite or Installed Interior Removable AND-N-2-01461-00002 029 165 0.18 027 14 -0.2 - NC SCS - -
W c
3
9 Full Divided Lite AND-N•2-01473-00001 030 170 018 027 13 <02 - NC SC -
FlnelightTM(grllles-between-the-glass) AND-N-2-01467.00001 030 170 018 027 13 1 <02 - NC SC
No Grilles AND-N•2-01462-00001 028 1.59 021 047 17 <02 - NC -Cl I S kill -
eeei Simulated Divided Lite or Installed Interior Removable AND•N•2-01462.00002 028 159 019 043 16 <02 NC SC S Z1 -
3 Y
�o E Full Divided Lite AND-N-2-01474-00001 029 165 019 043 15 402 NC SC 5
v, FmelightTM(grilles-between-the-glass) AND-N-2-01468-00001 029 1 65 019 043 15 <02 - NC SC 5 -
No Grilles AND-N•2-01459-00001 029 165 051 1 0 58 33 <02 - Z1 Z2 -
0
W Simulated Divided Lite or Installed Interior Removable AND.N.2-01459-00002 029 165 046rO47
30 <02 - - Zt Z2
v
� N Full Divided Lite AND-N-2-01471-00001 030 170 046 29 <02 - - Z1 ZZ ,
6
Flnellghti°(grilles-between-the-glass) AND.N-2-01465-00001 030 170 046 29 <0.2 - - 21 Z2 -
11
No Grilles AND-N•2-01546-00001 025 142 030 26 <02 NC - Z1
W S simulated Divided Lite or Installed Interior Removable AND.N.2-01546-00002 025 142 028 25 <0.
o NC Z1 -
m
Z Full Divided Lite AND-N-2-01552-00001 026 143 0.28 0.47 24 <02 NC - - Z1 -
3
FinalightTM(grilles-between-ther3lass) AND-N-2-01549-00001 026 148 028 047 24 <02 NC - Zt
400 Series Awning
No Grilles AND•N-2-01547-00001 025 142 020 046 20 <0.2 NC SC 1S Zt - -
d Y
W Simulated Divided Lite or Installed Interior Removable AND-N-2-01547-00002 025 142 019 042 20 <02 NC SC S 2_1 - -
Yy
E= Full Divided Lite AND-N-2-01553-00001 026 148 019 042 18 <02 NC SC ,s 21 -
H 3 FlnellghtT"(grdles-between-the-glass) AND-N-2-01550-00001 025 142 019 042 20 <02 NC SC Is Z1 -
No Grilles AND.N.2-01545-00001 026 148 046 0 57' 34 <02
Z1 Z2 Z3
c
Y
cavi �3 Simulated Divided Lite or Installed Interior Removable AND-N-2-01545-00002 026 1.48 042 051 32 402 - Zi 22
11
3 a m
Full Divided Lite AND-N-2.01551-00001 027 153 042 0.51 31 <02 - Z1 22
Flnellghtw(gdlles•between•the-glass) AND-N-2-01548.00001 026 148 0.42 051 32 <0.2 - Z7 Z2 -
3.0 Annealed or 3 1 Tempered Glass-w/Grilles 1•'or Greater
Simulated Divided Lite or Installed Interior Removable AND-N-2-01460-00003 029 165 026 043 19 <02 NC - - - -
e
a
3 Full Divided Lite AND-N-2-01478-00001 0.29 165 026 043 19 <02 NC - - -
0
J Firelight-(grilles-between4ho-glass) Na Na Na n/a Na n/a Na -
Simulated Divided Lite or Installed Interior Removable AND.N.2-01461-00003 029 165 016 024 13 <0 2, NC SC S - -
°a
W Full Divided Lite AND•N•2-01479-00001 029 165 016 024 13 <02 NC SC S - -
3 w
0
FlnelightTM(grilles•between4he-glass) We n/a Na n/a Na Na n/a - -
3
Simulated Divided Lite or Installed Interior Removable AND-N-2-01462.00003 028 159 017 039 15 <0.2 - NC SC S
W
3� Full Divided Lite AND-N-2-01480-00001 029 165 017 '0 39 13 <02 NC SC 5
NFinalightTM(grilles-between-the-glass) Na Na n/a Na Na n/a Na
Simulated Divided Lite or Installed Interior Removable AND-N-2-01459-00003 0.29 165 042 0.47 28 -02
Z1 -
W
a
Full Divided Lite AND-N-2-01477-00001 030 1.70 042 047 27 <02 Z7
a FlnelightTM(grilles•between•the-glass) Na We Na I Na Na Na Na - -
�e Simulated Divided Lite or Installed Interior Removable AND.N.2-01546-00003 025 142 025 OA2 23 <02 NC SC :S Zl -
u
Full Divided Lrte AND•N-2.01555-00001 026 1,48 025 042 22 <02 NC SC -
o= ,
3 FlnelightTM(gnlles-between-the-glass) n/a We Na Na Na n/a Na - - -
Page 9 of 155 Data cunent as of Dececmber 15,2014 and Is subject to change
9 See page 1 for more information
l
1 �
U.S. Canada
_ ENERGY- -ENERGY
_ STAR STAR
Andersen• Andersen " F'• NFRCCertiied oo'. M- !ao v6.0 v4.1 '
Product Line 8 Glass "Grille Type -i - rM1 - °Products- n
Product Type Type - - , _ Directory Number, > > to ..+` n
v
y, oC oC oGo
Z 2 4) N N N
�c Simulated Divided Lite or Installed Interior Removable AND-N-2-01547-00003 025 1.42 0.17 0.38 19 <132 NC SC QS Z1 -
W c o
3 Full Divided Lite AND-N-2-01556-00001 026 1.48 017 0.38 17 <02 NC SC Z1 - -
E_
3 FlnellghtT (grilles•between-theglass) Na Na Na Na Na Na Na - - - - -
�e Simulated Divided Lite or Installed Interior Removable 'ANM-2-01545-00003 026 1.48 038 046 29 <02 NC - Z1 Z2 -
$ N
3 Full Divided Lite AND-N-2-01554-00001 0.27 1.53 T38O41, 28 <02 NC - - Z1Finelight^(grilles-0etweendheglass) Na Na Na Na Na -
3.0 Annealed or 3 1 Tempered Pattern Glass-w/No Grilles and Grilles Less than 1"
No Grilles AND-N-2-01460-00004 029 1.65 031 053 22 <0 2 - NC - - - -
Simulated Divided Lite or installed Interior Removable AND-N-2-01460-00005 029 1.65 028 048 20 <0.2 - NC - - - - -
Full Divided Lite l Na n/a Na Na Na Na We -
Finellghtr'i(..Iles-between-theglass) Na We Na Na Na Na Na
No Grilles AND-N-2-01461-00004 029 1.65 019 029 15 <0.2 - NC SC S -
W c Simulated Divided Lite or Installed Interior Removable AND-N-2-01461-00005 029 165 018 027 14 <02 - NC -CI I Vs. -
Full Divided Lite Na Na Na Na Na n/a Na
Flnelight"(grilles-between-theglass) Na Na Na Na n/a We Na - - - -
No Grilles AND-N-2-01462-00004 0.28 1.59 021 0.47 17 <02 - NC SC YiaJIZI -
8 W CS.,
'° Simulated Divided Lite or Installed Interior Removable AND-N-2-01462-00005 028 1.59 019 043 16 <02 - NC SC Frw Zt
E Full Divided Lite Na Na Na Na Na Na Na - - -
400 Series Awning
Finelightr"(grilles-between4heglass) Na Na Na n/a Na Na Na - -
No Grilles AND-N-2-01459-00004 029 165 051 058 33 <0,2 Z1 Z2 -
e
c
NSimulated Divided Lite or Installed Interior Removable AN0.N-2-01459-00005 029 165 046 053 30 <02 - - Zt 22 -
, m
3
S m Full Divided Lite Na Na Na Na Na Na Na - - - -
o.
FlnellghtTM(grilles-between-theglass) Na Na Na Na We n/a Na
3.0 Annealed or 3.1 Tempered Pattern Glass-w/Grilles 1"or Greater
Simulated Divided Lite or Installed Interior Removable AND-N-2-01460-00006 0.29 1.65 0.26 043 19 402 - NC - - - -
e
3 Full Divided Lite Na n/a Na Na Na Na Na -
0
J FlnellghtT (gnlles-between-theglass) Na Na Na n/a Na Na Na - - -
Simulated Divided Lite or Installed Interior Removable AND-N-2-01461-00006 029 165 016 024 13 <0.2 - NC SC - -
°a
3 N Full Divided Lite Na Na Na Na Na nla Na . -
s
FInellghtTi'(grilles-between-the-glass) Na rife Na We We We I We '
Simulated Divided Lite or Installed Interior Removable AND.N.2-01462-00006 0 28 1.59 0 17 0 39 15 <0 2 - NC SC [S
e c
W
3 r Full Divided Lite Na Na Na Na Na Na Na - - - -
sE
� Finellght"'(grillesbetween-theglass) Na Na Na Na Na We Na - - - -
Simulated Divided Lite orinstalled Interior Removable AND-N•2-01459-0OOOfi 029 165 042 047 28 <02 . Z7 -
W
3� Full Divided Lite Na Na Na Na Na Na Na -
s a FinellghtTM(grilles-between4heglass) n. nla We Na Na Na nla
Page 10 01155 Data anent as of Dececmber 15,2014 and is subject to change
See page 1 for mare informe6on
• •
aio® - • • -
Type of Appliance Condensing,Tankless,Temperature controlled, continuous flow,
gas hot water system, Energy Star Qualified
Rinnai model number REU-KB3237FFUD-US
Operation/Installation Forced combustion; indoor only D��s
DEC[T'0'VF=
Minimum/Maximum Gas Rate(Input) 15,200- 199,000 BTU/h DD
Electrical Appliance: AC 126A�PP 'OR* — 7 2097
Temperature Controller: DC 12 Volts
Electrical Consumption Normal: 64 w Standby: 2 w Anti-frost protec}��.D�l�i�g
1��J� 6 DEF'T.
Ignition System Direct electronic ignition TOWN OF SOUTHOLP
Hot Water Capacity Minimum flow rate: 0.26 GPM
Minimum activation flow rate:-0.4 GPM
Maximum flow rate: 9.8 GPM
Temperature 98°- 120° F (factory default) Maximum temperature is selectable at
120° F or at 140° F; 980- 185° F available with the MCC-91-2
controller for commercial and hydronic applications
Temperature(without remote) 120° F (factory default)or 140° F
Approved Gas Types Natural or Propane(ensure unit matches gas type)
' Energy Factor(EF) Natural Gas: 0.95 Propane: 0.95
Service Connections Gas supply: 3/4 inch MNPT
Cold water inlet: 3/4 inch MNPT
Hot water outlet: 3/4 inch MNPT
Isolation &Pressure Relief Valves'Included Heavy duty forged brass-Webstone Isolator valves EXP E2, certified
to NSF/ANSI 61-8 for potable water
Water Flow Control Water flow sensor, electronic water control and by-pass control
Minimum/Maximum Water Supply Pressure 15- 150 PSI (50 PSI or above is recommended for maximum flow)
Rinnai is continually updating and'improving products;therefore, specifications are subject to change without,prior
notice:Local,'state,'provincial_and,fedeial-codes must-be adhered to prlor,to installation."
• 10 0. --------- ----+---, { --- --- -------
+ {
--�----Y---+----Y-------+---i— T----------a----+---i----+-------1----�---+,----Y------�---{----�----{--- ---i----+----�----�---
9.0
_t- ---_ _ �____ ____ _
i
__ �_ -_t___.� __- ----------- _ __i----Y_________ ____
__ _ t-i___t__
i
_ t .-Y___ ti _____ ____ ___ ____________ --------
____________
r� t __ i_ t_ _ t t _ i _Y---t i ` t_
__Y___t__-Y__ ____t___�___t___ _____i_-_t___i____t_______i____Y___t____Y______F___i___i-___i___ __,_-_t-------
17
E $•0
___
0) 7.0
-------- ----------
---. . _________ ___________._______.____.___1__-._______t ----
___________________________-________ __________ ___
- --------- ---i- i----r---4--- - ---i----i---
6.0 -----4-------=-- ----- - - ---- -------------- -- --- -- ----- ---1----------------
--------= ---{------=------------
LL t -----I----------------t------ -- - ----- --------------------_____= -- --5.0
- - --------------------------- j —
'
----- -- --------�----+
4.0
------------ -- ------ - r-------------------------------- ------------ ------------- ---
--- -
3.0 —--------
' ----- ---'--- -----------1 +---;----+--- —4 --{--Y — —
1
} ; _ { {
__i____Y__y____Y____ i____ ______t___i.___t--------.____t___t____�.______ ---------
___ ___
_r___1____t___} .ti___. ..____
___.*___t___-Y___r____
j___}___
______xi
__�___�_______________�________________________ _______
0.0 x
0 25 50 75 100 125 150
delta T-Temperature Rise(°F)
0 2012 Rinnai Corporation RU98i-SP 3/2012 SF oM�®
1 '
Controller MC-91-1 US (included)
Deluxe controller: MC-100V-1 US (optional)
Bathroom controller: BC-100V-1 US (optional)
- F - MCC-91-1 US(optional;for hydronic and commercial applications)
: Controller Cable Non-polarized two-core cable, minimum 22 AWG
Safety Devices • Flame failure-Flame Rod • Remaining flame (OHS)
• Boiling protection • Thermal fuse
• Combustion fan rpm check • Automatic frost protection
. Over current-glass fuse
Clearances from Combustibles • Top of heater-6 inches • Back of heater-0 inches
*24 inches"required for serviceability Front of heater-6 inches* • Bottom of heater- 12 inches
• Sides of heater-2 inches • From vent pipe-0 inches
Clearances from Non-combustibles • Top of heater-2 inches • Back of heater-0 inches_
* • Front of heater-6 inches* Bottom of heater- 12 inches
24 inches required for serviceability -
• Sides of heater- 1/2 inches From vent pipe-0 inches
Min./Max. Gas Supply Pressure Natural Gas: min 5" W.C. max 10.5" W.C.
Propane Gas: min 8" W.C. max 13.5" W.C.
Manifold Gas Pressure(inches W.C.) Natural Gas: high fire 3.1" W.C., low fire 0.51" W.C.
Propane Gas: high fire 3.7" W.C. low fire 0.52" W.C.
NOx Complies with South Coast Air Quality Management District 14 ng/J or
20 ppm NOx emission levels
Limited Heat exchanger: 12 years*for residential, 10 years for residential and space heating, and 5 years*for
Warranty commercial;,All other parts: 5 years*; Labor: 1 year;
(*3 years if used as a circulating water heater within a circulation loop,when the water heater is in
series with a circulation system and all circulating water flows through the water heater, and where an
aquastat/thermostat,timer,or an on-demand recirculation system is not incorporated.)
Refer to the manual for complete warranty information.
WEIGHT: 70.5 Ib(32 kg) CONDENSATE DJTLET CC o WATER
OT WATER QUILET GAS 0
o5.4(137) 10.1 (257.7)
0
0
2.0(52)) C O
B
J
D CONDENSATE l
H
n
M _ E G
LET
C
04M F
`° co S Lo
n K
N N r` in DIM Inches(mm) DIM Inches(mm)
LO
cq N A(GAS) 1.6(40.2) E 2.2(563)
A(COLD) 2.0(50.2) F 2.3(58.3)
A(HOT) 1.6(412) G 5.0(127.2)
o A(CONDENSATE 0 9(22 4) H 2.0(50)
rn co OUTLET) I 3.0( 6)
C,4 C oUd B f"5.0(127.2) J 7.1 (179)
C 1.9(47.8) K 18.3(466)
2.8 -87(222) A D 0.52(13.3)
(70.1)
Rinnai Corporation•103 International Drive•Peachtree City,GA 30269•Toll-Free 1-800-621-9419•Fax:678-364-8643•wwwAnnai us