Loading...
HomeMy WebLinkAbout41391-Z �o�SyFF�(,yCpG. Town of Southold 4/4/2017 z� P.O.Box 1179 53095 Main Rd ���►®� ��0� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38886 Date: 4/4/2017 THIS CERTIFIES that the building ALTERATION Location of Property: 1160 Town Harbor Ln, Southold SCTM#: 473889 Sec/Block/Lot: 64.-5-9 Subdivision: Filed Map No. Lot No. conforms-substantially to the Application for Building Permit heretofore filed in this office dated 2/22/2017 pursuant to which Building Permit No. 41391 dated 2/28/2017 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ALTERATIONS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Dobeck,Michael&Parker,Lauren of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED Outh(7d Signature �aoFFnc� TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41391 Date: 2/28/2017 Permission is hereby granted to: Dobeck, Michael & Parker, Lauren 200 W 79th St Apt 9P New York, NY 10024 To: make interior alterations to an existing single family dwelling as applied for. At premises located at: 1160 Town Harbor Ln, Southold SCTM #473889 Sec/Block/Lot# 64.-5-9 Pursuant to application dated 2/22/2017 an'Id approved by the Building Inspector. To expire on 8/30/2018. Fees: SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $305.60 CO -ALTERATION TO DWELLING $50.00 Total: $355.60 Building Inspector I ' I Form No.6 D [EC[EOV[E TOWN OF SOUTHOLD BUILDING DEPARTMENT D TOWN HALL 765-1802 MAR - 9 2017 APPLICATION FOR CERTIFICATE OF OCCUPANCY BUILDINGDEPT. This application must be filled in by typewriter or ink and submitted to the Building DepartmenTRWOZ30WOLD A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible,for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9,1957)non-conforming uses,or buildings and`pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. 3 —/-/7 New Construction: Old or Pre-existing Building: 1z (check one) ,� !, Location of Property: /•��© �ui t ffg4ar he, ✓o"d6f House No. Street Hamlet f Owner or Owners of Property: 9"06( ,�t70 •r L... ,we''!► 1,2,rkep Suffolk County Tax Map No 1000, Section Block Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate:� (check one) Fee Submitted: $ ?C-,J A AA .L co Applicant Sign [ 139 SOUlyolo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] OUNDATION 2ND [INSULATION [ FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: ��� 5,.�h)pm "J DATE 3 INSPECTOR BOE SOUI,yo �'YUOUM'�,0c� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] OUGH PLEIG. [ ] FOUNDATION 2ND [ INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] F E SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECT CAL (FINAL) REMARKS: R)kl � DATE 3 - 1 M INSPECTOR �aoE souryo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [WF'I IULATION FRAMING / STRAPPING [ NAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ]. FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: Ly/ DATE 3 3� INSPECTOR ��W ilii� i��.�����-►. �.. w r Y • 0 .r • TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined 20 Single&Separate Storm-Water Assessment Form Contact: (fine(rn NI,1nye 1 s, ,2_-A . Approved 15 1201 Mailto. m Arck, rye Q 51'3(6 Disapproved a/c f•b--'9 X Zl9 2 WC�d!Q ue tz y 11-?7 2� Phone: 5 1 (o g L(Z • K Z3 a Expiration 20 99EVIR D D Building Inspector FEB 2 2 2017 APPLICATION FOR BUILDING PERMIT BUILDING DEPT- Date �e�(Ucr11� Gd ,20_d_TOWN OF SOUTHOLD INSTRUCTIONS a. This application MUST be completely,filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws,Ordinances or Regulations, for the construction of buildings,additions, or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of app '91 a t or name,if a corporation) 960 zl!vesf 794?'fr 60 &Vf%lG� lr10�/ (Mailing address of applicant State whether applicant is owner,lessee, agent, architect, engineer, general contractor, electrician, plumber or builder 0cvA &/- Name of owner of premises /U(� �f k/9U��- Cti L ✓2d� f'&11' (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section �� Block 5— Lot Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy E X 1 i1 Q 1 b. Intended use and occupancy 6-e 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire,new construction: Front Rear .Depth Height Number of Stories 9. Size of lot: Front I 7 o S� 1 Rear 13 'S b Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law,ordinance or regulation?YE5 NO­j/ 13.Will lot be re-graded?YES NO_)�­Will excess fill be removed from premises?YES NO A)lA 14.Names of Owner of premises Address Phone No. Name of Architect-R na el a. A4a,0 a P Is � A Address R0 k)c Q Ra &!- PfUe 1467"'-2- 5�I to $4$ S29,.2-- Name 29,.2Name of Contractor �- Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? *YES NO * IF YES, D.E.C.PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? *YES NO * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF hii► or A"el Ddled< -,'- ""On P"hO being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the O W h G+"S (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief,and that the work will be performed in the manner set forth in the application filed therewith. Sworn tpl-before me thifvr�r4`"e y 040/7 10 Tr` day of 6 ZA RMA Notary Public-State of New York N0.01PA8351578 '& X, X ,�'— P" Notary Publi Qualified in Suffolk County Signature o rant My Commission Expires Dec 5,2020 8 t 416 off- Y � _ a � • ; a ... „c........ ���� �I,��. e - ����i. y� , ,.. �� .� xR,a ' _� !�. i 5 {{µr �. �' � I mow_ ��# MAP 4w •► 4P w � w w 4 .r +i _ - January 31, 2017 Town of Southold Building Department 53095 Route 25 PO Box 1179 Southold,NY 11971 Re: DoDeck Residence 1160 Town Harbor Lane Southold,NY 11971 Section: 64 Block: 5 Lot: 9 To Whom It May Concern, I, Michael Dobeck,the homeowner located at 1160 Town Harbor Lane, Southold,NY 11971, authorize Angela Mangels of AM Architectural Designs, P.C. its employees to represent me in reference with the Town of Southold Building Department Application process in reference to the work being requested for this property. You may contact me with any questions at(347)245-7956. Thank you for your time. Sincereely0, J eu'�t(— RA-1 Michael Dobeck .r au/'�� �ar4r Homeowner "^lar9217 04:23p Eda 6313684073 p.1 CHELSEA HOME REMODELING INC. 200 Warner Road Huntington,NY 11743 (631) 368-4677 -Fax(631) 368-4676 Tranmittal Date: - -17 I Number of Pages indudin cover sheet To: Ur ►11 � L , Company`_ wn o f 3au-�ho 1 Fax # lo5l- 7.1off�- X750 Phone # tq,-3f - `71o� ISU i2 From: Re: e mance, ed _ Ellolni'*nq are- Y r pa r v {Luer From t PECONIC SURVEY , P. C. C516)765-i-70"' a 516)765-170"' D o ® P02 ,.. o - BLOG:DEPT. TOWN OF SOIrT-C!LD _ a� Al R�G� it a, . t,a`•�. //' N lop°roa'' -. SECURITY TME 8 GUARANTY CO. PERRY T. CRISCJTELLI 9 of S� 4 $0200 46 TELLJ ,tl1. SURVEY FOR AREA=2$,367 Sq.fr. PE R Y T CRISCI TELLI& JILL B, CRISCI TELLI AT SOUTHOLD TOW1V OF SOUTHOLD SUFFOLK COU1lTY,N.Y 1000-84-05-09 Scale: I"=1 "=-30' June 11,7992 �a 4AN0 S� 48618 Prepwed In accordance with Jho mWmdm slandords for Jill& sarvoys oc asiabCsh®d (5 1? by Jho L.J.A.L,S. and approved and adopted - Q lar such vsm by The Nae Yark all Led 0.4969 �a Tula Assockil&% sour �f9ja� . PROPOSED: IN AL TERA TION 6ENEFAL- NOTE5 MFEFI/` L- NOTE5, �.+ N260 39'20"W 137.50' 1. THE FOLLOWING REFERENCE WAS USED IN THEDES/GNOF THE 8. ALL FOUNDATIONS SHALL REST ON UNDISTURBED, WELL COMPACTED I N 5T I�UGT 10 N 5 f:�O F T f1 E I N 5T ttLLE K STRUCTURE: AMERICAN FORESTAND PAPER ASSOCIATION(AF GRANULAR SOIL OF ONE TON PSFBEAR/NGCAPAC/TY(MIN.)ALL CONCRETE Q &PA) WOOD FRAME CONSTRUCTION MANUAL FOR ONE AND WORK SHALL CONFORM TO THE REQUIREMENTS AND RECOMMENDATIONS � TWO FA MIL Y D WEI L INGS 1. ALL SPECIFIED FASTENERS MUSTBEINSTALLED ACCORDING TO THE OFACI-84 SPEC/F/CATIONS FOR STRUCTURAL CONCRETEFOR BUILDINGS SITE INFORMATION NOTE. ALL CONSTRUCTIONIS TO BEINACCORDANCEW/THE2015 (FC-_3000 PSIJ,'RE/NFORC/NG STEEL SHALL CONFORM TO ASTMA-615 INSTRUCTIONS IN THE CURRENT S/MPSON(WOOD CONSTRUCTION CATALOG). LV INTERNATIONAL RES/DENT/AL CODE&ALL PARTS THEREOF,SHALL BE " INCORRECT FASTENER QUANT/TY,SIZE, TYPE,MA TER/AL,OR F/N/SHMA Y Q SEC: 64 THIS SITEPLANISNOTA LEGAL SURVEY.ITIS CONSTRUCTED TO SAFELYSUPPORTALLLOADS,INCLUD/NGDEAD GRADE60.ALL FOUNDATION WALLS TOBEB THK.&POUREDCONCRETE CAUSE THECONNECTIONTOFAIL. I6DFASTENERSARECOMMONNA/LS -I I FOR ILLUSTRATION PURPOSES ONLY.ALL FOOTINGS.ALL TRENCHFOOT/NGS TO FOLLOW LOCAL CODES O Q BLK' S LOADS,LIVE LOADS,ROOFLOADS,FLOOR LOADS,SNOW LOADS, (8 GA x 31)&CANNOT BE REPLACED W/16D SINKERS(9 GA x 31 J UNLESS -J � I DIMENSIONS,SETBACKS,LOCATIONS& WIND LOADS&SEISMICLOADSASPRESCRIBED BYTHE " OTHERWISE SPECIFIED, O LOT- 9 S TRUC TURES WERE TA KEN FROM SUR VE Y 9. SILL ANCHORSINFOUNDAT/ON WALLS TOBE5/8 D/AM. 2015INTERNATIONAL RESIDENTIAL CODE METAL WASHERS UNDER NUTS LOCA TED 12"MAX.FROM EACH 0 AREA: 25,367 SO FT PREPARED BY.PECON/C SURVEYORS 2. BOLT HOLES SHOULD BEA MINIMUM OF 1"&NO MORE THA NA MAXIMUM LQ 4� O CORNEROFSILL&36"O.C.MAX.USING MIN.OF 2 TWOANCHORS � P.O.BOX 909,MAIN ROAD 2. CONSTRUCTION lNREG/ONS WHERE THEBASIC WIND " () OF 1"LARGER THAN THE BOLT O PER SILL PIECE FOR UPLIFT AND 23 0.C FOR LA TERAL AND SHEAR O C� SOUTHOLD,N.Y. 11971 SPEEDS EQUAL OR EXCEED 130 MPHSHALL BE ALL NEWSILLS TO BE OFACQ TREATED LUMBER W/S/LL INSULATION 3. INSTALL ALL SPECIFIED FASTENERS BEFORE LOADING THECONNECT/ON � DATED: JUNE 11, 1992 DES/GNED TO COMPL Y WITH WFCM(HIGH WIND I I ED/TION)HANDBOOK. BETWEENS/LLS&CONCRETEBLOCK. 4. USEPROPERSAFETYEQUIPMENT O O O 3. NO PLUMBING WORK TO BE COMPLETED AT THIS TIME. 10. NO MASONRY WORKAT THIS TIME 5. PNEUMATIC OR POWDER-ACTUATED FASTENERS MAYDEFLECT& �' 0 11. NO MECHANICAL WORKAT THIS TIME INJURE THE OPERATOR OR OTHERS NAIL TOOLS MAYBE USED TO �1 CQ O (f)4. THEARCHITECT SHALL NOT BERESPONS/BLEFOR THE WORK }Q a� INSTALL CONNECTORSPROVIDED THECORRECTQUANT/TY& TYPEOF Ole �- RELATING TO THE CONTRACTORS SAFETYPRECAUTIONS OR TO 'v MEANS,METHODS, TECHNIQUES OR PROCEDURES REQUIRED 12. THEARCH/TECT HAS NOT BEEN RETAINED TO PERFORM NAILS ARE PROPERL Y INSTAL LED IN THENAIL HOLES. TOOLS W/NAIL Q o F/ELDSUPERVISIONDURINGCONSTRUCTION. HOLE MECHANISMS SHOULD BE USED.FOLLOW THE MANUFACTURERS I FOR THECONTRACTOR TO PERFORM H/S WORK O INSTRUCTIONS&USE THEAPPROPRIATESAfETYEQUIPMENT. I 5. ALL STRUCTURAL LUMBER TO BE DOUGLAS FIR.#2 OR BETTER, 13. IF/N THE COURSE OFCONSTRUCTION,A CONDITIONEXISTS WHICH Q„ DISAGREES W/THA T AS INDICATED ON THESE PLANS, THE 6. JOIST SHALL BEAR COMPLETEL YON THE CONNECTOR SEA T& THE GAP �/ O W/UN/T STRESS OERIORF 950#WAPSI&S TO BE S 2'x4'CONSTRUCTION.ICI TY CONTRACTOR SHALL STOP WORK&NOTIFY THEARCH/TECT. SHOULD BETWEEN THEJOIST END&THE HDR SHALL NOT EXCEED 1.H PER ASTM �I ILL IN00. ALL EXTERIOR WALLS W'CON TRUCOUBLETHE CON TRACTOR FAIL TO FOLLOW THIS PROCEDURE&CONTINUE TES T S TA NDA RDS. O ALL INTERIOR WALLS TO BEOF2'x4'CONSTRUCTION DOUBLE ��' STUDS ATALL OPENINGS AND BEAR/NG PARTITIONS. ALL TO WORK, THE CONTRACTOR SHALL ASSUMEALL RESPONSIBILITY& I STRUCTURAL POS TS ARE TO BE SOL IDL YBLOCKED TO TOP OF LIAB/LITYAR/SING THEREFROM. I FOUNDA TION WA L OR SUPPORT COL Ud)N BELOW. 70,2' , 6. DOUBLEALL JOISTS,HEADERS&TRIMMERS AROUND ALL OPENINGS f O U N D AT I O N NOTE 5 8' 22.0 &UNDERALL PARTITIONS USE TECO HANGERS. PROVIDEBRIDGING EX. I FA MIL Y 23' d MAX. 8'0"OC&CONTINUOUS WHERE POSSIBLE. BEAMS& 1. 16"D/AM.CONCRETE COLUMN FOOTING,3000 PS!@28 DAYS ai HEADERS OF ENGINEERED WOOD ARE TO BE MIN OFMICROLAM I M DWELLING MIN.F3=2600PS/REPET/T/VE MEMBERS W/E=21 OR BETTERzn . 2 ASSUMED SOIL BEARING CAPACITY 2 TON PSF,SUBJECT TO INSPECT/ON N W n 7. DO NOT SCALE DRAWINGS. CONTRACTOR TO VER/FYALL DIMENSIONS, &VERIFICATION ELEVATIONS&GRADES AT THE T/ME OFCONSTRUCT/ON. LARGE 3. ALL FOOTINGS TO BE CARRIED DOWN TO UNDISTURBED SOIL 20 0' SCALE DRAWINGS TAKE PRECEDENCE OVER SMALL SCALE DRAWINGS. 4. CONCRETE SHALL NOT BE POURED ON FROZEN GROUND OR IN FREEZING WEATHER o PROPOSED: z 5. NEW STRUCTURES WILL MEET 130 MPH WIND ZONE REQUIREMENTS I INTERIOR AL TERA TION (CATHEDRAL CL G. & INSTALL 3 SKYLIGHTS) I W L jy 5 "" �ailtl.4 k�9n v��p,.4 Eue 6r. Yf"�� ���i ';", I �;IS�INGWr1LL5 0 IZFMAII J ® SMOKE/00 Dr-rr-c,For tis p K Fl r: .J 2015 I#'G N0717'/ .i A T ►� 76.,-1F07 31",,° ; ti4 F:R Tr7.. O ' ('...r.,-r;. n, n, 1. TVIC� REQU SEE U� FOR P0l..)5ED 001"GREfF:. OO 2. ROG'' - FRAi>,G; ,,,< t 483.34' 3. !i`JS'..II_.AT!ON 11 --� r in-^I/ At T `Q _ _ ----- - _ 137.50' �. E,!^.!;C ' cLE ,T;FO I C. . ,:aus 9 � ----�'-' s-;r CO3�;�?LETT. FOR C.O. � --- ALL COidSTRliCT;O°, SI IAL L ?41EET THE ` S31°31' 10"E F'"OUIREMENTS OF-r!-;�CODES OF(`er`ti'V YORl< STATE. PIOT RES?ONSIvLE FOR TOWN HARBOR LANE DEs;cN OR coNsTRucTioN eRRORs, z a a F.LOT F L-AN SCALE: 1'=20' 0 gig CCC � r%,\f 17v EX.FOUNDATION WALL&FOOTING TO REMAIN EX.WALL CONSTRUCTION TO REMAIN EXISTING ROOF CONSTRUCTION.- V 240#ASPHALTON30Ib.FELTOVER 1/2"PL YC OX. V 30 X60"SKYLIGHT WITH FLASHING AROUND EXISTING RIDGE TO REMAIN. LV N DOUBLE FRAMING AROUND SKYLIGHT Z Q z Q N OPENINGS TECOALL CONNECTIONS. -_-_j �i w E X I5 T I N G DINING I M, E X15T IN 6 WOMEN TYPAT3LOCATIDNS. � � W W WcJr 2X6 RR @ 12'O.C. 12 z TO REMAIN.NO CHANGE. TO REMAIN.NO CHANGE. o Z Q fl i O Ex. I X A-FT IG 8' "CLG.HT. 8'0"CLG.HT. o o �- GUTTER&LEADERS NEW 1/2"GYP.BD.FINISH PROVIDEf VENTILATION TO COD EX.C✓TO REMAIN W W 0 1:0" R21INSULA TION 0" N 0.H EX.HDR. TO REMAIN` O I I I N WWALL HT.=+rll'3" + z Q EX.HDR.&LALL YCOL UMNS TO REMAI r ` O EX,DEN FA. rrFCMEfN - 9 � - � - I I i EX.RIDGE TO REMAIN I I I v o TYP.OFALL LOCATIONS. -f -i `� - °� NO CHANGE. I I o I I I I I I EX.FRAME WALL TO REMAIN. I S.D./C.0.I v M I I I EX..IFIREPLACE TO REMAIN. j ®DEr j a j I I NO�HANGE. I 1 Lu 23=0" FINISHED FLOOR ON 3/4"SUB FLOORING EX.FJ TO REMAIN.NO CHANGE. TO REMAIN.NO CHANGE. w I I I I I o I I I GRADE EX.HDR.&COLUMNS TO REMAIN �XISTINC�DAN w " �``� E __ �__ ARCHITECT SEAL: � Q �o COMPACT FILL EX..FOUNDATION WALLS TO REMAIN EX.P.C.SLAB TO REMAIN v F'F` 2=0" 2=0 oNEW CATHEDRAL CL G. 1NEW /NV 299 SQ.FT. 130'X60- I t?0 X60" I 130 X60" I w L=>8% I SKYLIGHT I (SKYLIGHT I I SKYLIGHT I V0 TE V=>4% 1 1 1 I 1 I DOUBL E FRAMING I 1 I 1 1 AROUND SKYLIGHT p o ( I I I I I OPENINGS, TECO ALL CONNECTIONS. EX.P.C.SLAB � L_- _) L_-J L_ --1 TYPAT3 z i 0"WALL HT. TO REMAIN LOCATIONS. EX. WINDOWS TO REMAIN. NO CHANGE. NOTE.NEWSKYLIGHTOUTSIDEFRAME EDGE TO ALIGN WITH OUTSIDEFRAME OF SCA1E.'1/4"=1'-0" EX5T I N G F O U N I)ATI O N Ft-AN SCALE1/4"= '-0" X. ; O MAIN EX WALL CONSTRUCTION TO REMAIN EXISTING FRONT WINDOW. _ SHEET#.• © 5}I t... � .,� ., Y -.. 1 (`j1'xA:J!� V,✓t LJE_J OF 12�OF05UD INTE10� ALTEI�F ON-F-I_AN - rSCALE 1/4 1-0 ATTHEF/RSTFLOORDEN {