HomeMy WebLinkAbout41110-Z �o�svFFot,r�sTOWN OF SOUTHOLD BUILDING DEPARTMENT y z TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41110 Date: 10/25/2016 Permission is hereby granted to: 13405 Main Road LLC 13405 Route 25 PO BOX 93 Mattituck, NY 11952 To: make alterations to an existing commercial building (dermatologist office) as applied for. Vn /J— ("'DorK r tI - dMQ7, At premises located at: 13405 Route 25, Mattituck SCTM # 473889 Sec/Block/Lot# 140.-3-34 Pursuant to application dated 10/14/2016 and approved by the Building Inspector. To expire on 4/26/2018. Fees: COMMERCIAL ADDITION/ALTERATION $366.00 CO -COMMERCIAL $50.00 Total: $416.00 Building Inspector Form No.6 TOWN OF SOUTHOL.D BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: L Accurate survey of property showing all property lines, streets, building and unusual natural or topographic Features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00, Additions to dwelling$50.00, Alterations to dwelling S50.00, Swimming pool S50.00, Accessory building$50.00,Additions to accessory building$50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial $15.00 Date. 10/03/2016 New Construction: Old or Pre-existing Building: X (check one) Location of Property: 13405 Main Road Mattituck House No. Street Hamlet Owner or Owners of Property: 13405 Main Road LLC Suffolk County Tax Map No 1000, Section 140 Block 03 Lot 034 Subdivision Filed Map. Lot: Permit No. I 1 Date of Permit. Applicant: Frank nlotal0 Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: X (check one) Fee Submitted: S r Applicant Signature FIELD INSPECTION REPORT I DATE COMMENTS . -Z b FOUNDATION(IST) �' y ------------------------------------- FOUNDATION (2ND) z ®,o ROUGH FRAMING& H PLUMBING i INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL,COMMENTS CA o z m � O - z � y d b H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 ,-sets of Building Plans TEL: (631) 765-1502 Planning Board approval FAX: (631) 765-9502 --O5 rvey SoutholdTown.NorthFork.net PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees ­00.Application Flood Permit Examined _,20 Single&Separate 10 Storm-Water Assessment Form ZContact: Approved 2( t Disapproved a/c Phone: Expiration ,20 Q(� Building Inspector DPPLICATION FOR BUILDING PERMIT ®�� q 2016 Date 0 3 , 201 6 NGDE• INSTRUCTIONS a. T i0iSG 9�eD completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. „ (Signature of applicant or name,i a corporation) /1- WN V 12,0/v E;Tf LS= �19C(P)1-'� 9 C.. !l rc Z7 � ST 2U10 �. A)ELVyoI"/G'I �y (pl6 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Acro ITrLr Name of owner of premises 1�� S� {NI N �Z,3 A0 D—C, (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: \ AW &DAD 1'Y�A-rT 1-TI) C,1e-, House Number Street '" ° k-'= Hamlet - County Tax Map No. 1000 Section I ` ,Block ` `',`` 'J:'' Lot Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy T q F 1,?S S,�, pl MF i' ►t 5,0 AU21 C-1 b. Intended use and occupancy NO U-jA.N GjC 3. Nature of work (check which applicable): New Building ;Addition Alteration V/ Repair Removal Demolition Other Work NIcrS- 1 ►p?R,o�- AC-i (Description) 4. Estimated Cost Fee :(To be paid on filing this application) 5. If dwelling, number of dwelling units 14A Number of dwelling units on each floor AM If garage, number of cars ALA ' 6. If business, commercial or mixed occupancy, specify nature and extent,of each type of use"D"Aat�LOO nm(x 7. Dimensions of existing structures, if any: Front Rear; Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front m.- Rear Depth Height Number of Stories,,�'1-1,777.— '3 ` 8. Dimensions of entire new construction: Front Rear i ¢'A-j Depth Height Number of Stories :M ' J 9. Size of lot: Front Rear Depth _ 7 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated flA11)LrF,-r S u S 1 Jj i-C-S S 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO\/Will excess fill be removed from premises? YES NO 14.Names of Owner of premises 13 q Q S`M F1IJ 1-b•QWdress Yn�i i�-r�cJ�i N y Phone No. Name of Architect 'DAM SN'yDff t, Address 116 EZ) S}'Ny 1�'Y Phone No Z►Z-G'�9.g IO(Z> x12. Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAYBE 13EQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. i 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any Point on property is at 10 feet or below, must providie topographical data on survey. . 18. Are there any covenants and restrictions with respect to this property? * YES NO v * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) �'D A N\ S��(Q r R, being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the AT-ch LLQ (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this .3 day uto 6t/-- Zo NKIN C.YIP otaryPublic,state of New Yo otar Public No.V1Y16280020 Y a alitied in Nassau County Signature of Applicant Commission Expires April 14,2 SOUTHOLD TOWN FIRE MARSHALL -- NOTES & COMMENTS - BUSINESS/JOB �c�w � c r"_ C(2,60P S/B/L r DATE Date Notes Womment �(9 /Vo //U I/ wu '� I 3•`4'rd,9:t�E�4r`�t,;a:�::'.:7su. i'r'." ,;s, w, �.•�Q.,. 1^s"'..je':�t7r ..`.=T"r; +.'J?.°aro`rJ..':d.'.'t-.`K.�9.,t- ���•"_ e. q,:`# k"•e'ec.,..»; +; ''tij,y a•'1 '.t;:yta •+z.ts'a:. i:i 1` +iY«,s S..;:•'•:L�'^ ,.'ate.*_•a:rb.;.« i'va' ,^„t: Dh z � I A` .,rn'z.J-�r K i Y`k aT'y:s°'.., ti sa; a •�.`•'y us "r�.:'k'},'ri-*`;•�f'�an., ..�. w;j':��,;t,. ?{'-,.,kt�:t =��.t''"e'�'�.,_M` .�'z� �°'--9 ..f7�� k.2?z 5 ".}'��;z+nc yy 64 {-,r..sh�:i �;::ix F s4J,.a::.t•�v7j� 'Cas;' +7 '- �,✓.: �:ra., !:.'f mss. < �-v1'!•t •=2"�. e;'-1,4:,,a.� ,�....�..�g.....�:...`..,,-u�gyz. ?� -+, ":Y;,:sy# "! `.fit � k}��•,,r.....�i :'^:`rr:'�.>a.�i`i: •t�',•°sa&�'si�%.. ?•':lk..' .,. ,. „�..•: �yy`atf.,,�,a:- r•.e -r'f ''z'--`.��.xc-' '�'�.,x m i��`;•``•. .'lf\.��'#��S �'J nsrs� .r. ,e^{'-�1*�:y3�ix'-s7'..��'.r,G.�P "'•7c�`i';k.',4'�.c� V''�r ~—( sl` ..'1`$�.t,� °"�i;.e"ria ifpt„"}a M�'�.is3�`�.",.,'''" t."» ,•'te�.i •.�' r ffii, FIRENOTES.docx IT Designing Environments That work. Transmittal To: Southold Building Department From: Kenneth Bart Company: Town Hall Annex Building Date&Time: 10/13/2016 54375 Route 25 Client Name: Schweiger Dermatology P.O. Box 1179 Project Name: SDG Mattituck Mattituck, NY 11952 Project Number: E2623 Telephone: 631-765-1802 Auth Number: cc: Total#of pages, including cover: 1 We are sending you: Via: Receipt# Distribution: ® prints ❑shop drawings ❑ mail ❑ project file ❑ reproduction ❑samples ®overnight ❑ project director ❑ sketches ❑final art ❑ messenger ❑administration file ❑specifications ❑copy of letter ❑ Pick-up ❑accounting ❑ bulletin no: ® other—see below ❑ Environetics These are: ® per your request ❑for approval, please sign&return ❑ approved ❑for your information and use ❑for bid/budget by: ❑ approved as noted ❑for your review and comments ❑ other—see below ❑ returned for changes Regarding: Please include Environetics Project Name and Number on all correspondence. Qty Number Date Description 4 sets 10/13/2016 Sets of signed and sealed construction drawings for filing 1 10/3/2016 Southold Permit application Remarks: 116 East 27th Street New York Architecture Second Floor Philadelphia Interiors New York,NY 10016 New Jersey Engineering T 212 679.8100 Los Angeles Planning F 212 68S 9044 Seoul Stainability A Dimon of Enwronetia Group Incorporated Environetics com �r% path exi 5 Ilk. 1.1 Coin K r 1011, S& 11-M W: IUL G E R 5 C/o H W E11-1 � 'I DERMATOLOGY GROUP ViAl C( D N F F";_ "'Y: rJ DE RM Y G R OU P E' �!� T _' -)i,: i rJi, T [7 ") !_D ' E", TG15-4,,-',1�2 t,' JM 1_0 4 lr,�A ROR THE INSFECIIJONS: a. lot'i Ivo REQUIRED PROPOSED NON -STRUCTURAL INTERIOR ALTERATION I. F"-'U dDA_"' CLIENT: FOR POURED CONCRETE 2. ROUGH - F IR A M,I NI G & P L U i'v',D"!N G 3. INSULATION AT 4. FINAL - MISTRUCTION I,,',UST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL THE REQUIREMENTS OF THE CODES OF NEW r on rl.Jil YORK STATE. NOT RESPO'NSIBLE FOR 134 0 5 MAIN ROAD tlof.j�:ul DESIGN OR CONSTRUCTION ERRORS. V CONSULTANT: n' �� kA���� ��,. e MATTITUCK NY 11952 �c CEILING DETAILS BUILDING DEPARTMENT NOTES SITE INFORMATION 1. BUILDING IS OCCUPIED AS SINGLE TENANT SPACE AND SHALL COMPLY WITH BLOCK: 03 PROJECT HEAVY DUTY MAIN TEE SPLICE 11/2 CHANNEL,APPROX.4'-0"O.C., PROVISIONS OF ALL LOCAL&STATE BUILDING DEPARTMENT REGULATIONS. LOT: 034 Oil NORTH COUPLING(OCCURS AT RANDOM) MAY OCCUR DIRECTLY OVER LIGHT N 760 00' 1 E 138.54' ZONING: HAMLET BUSINESS 4D 2. ALL INTERIOR WOOD TO BE USED ONLY AS PERMITTED BY ALL LOCAL&STATE X BUILDING DEPT.REGULATIONS. z EXISTING USE: PROFESSIONAL OFFICE ul HEAVY DUTY CROSS TEE MAY BE 1 1/2 Lk 3. ALL INTERIOR FINISH MATERIALS SHALL BE INSTALLED AS PERMITTED BY ALL AREA OF WORK: 290 SF XISTING PA KING PACE OR 1"HIGH,AND MAY BE 2'-0"O.C. %1% LOCAL&STATE BUILDING DEPARTMENT REGULATIONS. HE RECESSED FIXTURE .0.ox TOTAL BLDG AREA: 2100 SF MAY BE SUPPORTED BY TFJFe 4. EXIT LIGHTS AND SIGNS SHALL BE LOCATED AT ALL EXITS AND AS REQUIRED TOTAL USEABLE AREA: 11768 SF ` '� �c ��� MAIN TEES SPACED 2'-VOR UNDER ALL LOCAL&STATE BUILDING DEPT.REGULATIONS. 1/4"DIA.GALV.STEEL ROD NOT 4'-0"O.C.FOR FIX'.T'C�ES ARCHITECTURAL TO EXCEED 4'-6"O.C. WEIGHINGIP-116 50 5. ALL EXIT SIGNS WILL BE ON EMERGENCY BATTERY EQUIPMENT POUNQ&9S PER IRS 5.3. w w 6. ALL ACOUSTICAL OR RATED PARTITIONS SHALL EXTEND TO THE SLAB ABOVE. m Lu of 0 CEILING HIGH PARTITIONS SHALL BE BRACED TO THE DECK ABOVE. co W LL_ (D 49 7' M Ve; DIRECT HANG CLIP CAT.#546.50.SM VARIES TO SUIT INSTALLATION F- M C) Z Z 9.8' 71.5' (OR OTHER APPROVED CLIPS) CLEARANCE AND LIGHT FIXTURE HEIGHT Lu 2 w =i % 7. ALL PENETRATIONS OF RATED CONSTRUCTION SHALL COMPLY WITH STATE& w =) F- --I Li- ce) m z w C/) C:) LOCAL BUILDING DEPT.REGULATIONS. Lu C14 CIO y CO % Cn ISSUE HISTORY: COO 8. PLUMBING FIXTURES SHALL COMPLY WITH ALL STATE&LOCAL BUILDING DEPT. HEAVY DUTY MAIN TEE-48"O.C.MAX. EXIST.1 STORY CONIC BLOCK BUILDING WITH BRICK FACE 0i (SHAPE AND DESIGN AS APPROVED) 01 T-100 COVER SHEET,SITE PLAN&RISER DIAGRAM • 9. CONSTRUCTION WORK WILL BE CONFINED TO THE WORK AREA INTERIOR AND NO. 13405 Cn AREA OF NEW ADDITION,AND WILL NOT CREATE,DIRT OR OTHER SUCH TYPICAL CEILING GRID DETAIL CONSTRUCTION&POWER/DATA PLAN,PART. w 11/2 COLD ROLLED 16 GA STEEL SUSPENDED INCONVENIENCES. 02 A-100 REFLECTED CEILING PLAN,PART.FINISH PLAN, 0 0 CHANNEL 475#APPROX.4'-6"O.C.(NOTE:LARGER NOTE:CEILING SUSPENSION SYSTEM CAN BE WIRES AS PER SCHEDULES AND NOTES OR HEAVIER CHANNEL MAY BE USED WHEN NYS BUILDING CODE IN LIEU OF BLACK IRON SUSPENSION 10. ALL WORK SHALL BE DONE IN ACCORDANCE W/THE BUILDING CODE OF THE THE u L U C/) Uf LL t2.7 REQUIRED BY BUILDING CODE) SYSTEM STATE OF NEW YORK AND ALL OTHER CODES,LAWS AND ORDINANCES HAVING OVERALL REFLECTED CEILING PLAN,OVERALL FINISH 0 JURISDICTION. 03 A-101 PLAN,SCHEDULES,NOTES AND DETAILS 0 1? 77 CP AREA OF INTERIOR 11. CONSTRUCTION OPERATION WILL NOT BLOCK HALLWAY OR MEANS OF EGRESS. < RENOVATION GAT CLIP 461.5L CAT.#16.59.SM 21 (OR OTHER APPROVED MEANS) 290 SF± APPLICABLE CODES REFLECTED CEILING NOTES 0 C/) HC rn NOTES: 1. REFER TO DRAWINGS GENERAL NOTES FOR ADDITIONAL INFORMATION AND SPECIFICATIONS, Q� N.Y.S.BUILDING CODE:2010 INCLUDING LATEST UPDATES LC3 j 1. AT EACH END OF LIGHT FIXTURE AN INTERLOCKING GROSS TEE OR LOCKING 2. THE INTENT OF THIS REFLECTED CEILING PLAN IS TO SHOW RELATIONSHIPS;BETWEEN WALLS N.Y.S EXISTING BUILDING CODE:2010 INCLUDING LATEST UPDATES BAR MUST BE USED. HC AND CEILING,AND LOCATIONS OF KEY MECHANICAL AND ELECTRICAL FEATURES.FOR k. MIp, 2. THE TOTAL WEIGHT OF A LIGHT FIXTURE AND OTHER EQUIPMENT(AIR BOXES, N.Y.S.PLUMBING CODE:2010 INCLUDING LATEST UPDATES COMPLETE MECHANICAL AND ELECTRICAL INFORMATION,REFER TO M.E.P.DRAWINGS. 0 CN ETC.)AND CEILING MATERIAL SUPPORTED BY THE MAIN BEAM MUST NOT I LAN AND LO 3. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THIS REFLECTED CEI LING P EX. WD SIGN� T_ C" EXCEED THE ALLOWABLE DEFLECTION OF 1/360 OF ITS SPAN DEFLECTION. N.Y.S.MECHANICAL CODE:2010 INCLUDING LATEST UPDATES ENGINEERING DRAWINGS FOR CLARIFICATION. T_ DATA MUST BE FURNISHED AND CERTIFIED BY THE MANUFACTURER 4. CONTRACTOR SHALL VERIFY ALL CEILING PLENUM CONDITIONS TO ASSURE CLEARANCE OF < >_ N.Y.S.FIRE CODE:2010 INCLUDING LATEST UPDATES DUCTWORK,PIPING AND OTHER OBSTRUCTION WITH THE CEILING HEIGHTS SPECIFIED,AND \L-L - - - - - - - -�K 7 W6 0 Z THE LOCATIONS OF THE LIGHT FIXTURES SHOWN.CONTRACTOR SHALL PROVIDE CEILING ACCESSIBILITY: 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN,]CC-ANSI A-117.1-2009 TRANSITIONS WITH GYPSUM BOARD AND METAL SHADOW MOLDING WHERE WHERE LOWER C) < CEILINGS ARE REQUIRED DUE TO CLEARANCE PROBLEMS. 2 P1-B.MOORE REGAL SELECT WATERBORNE 5. CONTRACTOR SHALL VERIFY ADEQUATE SERVICE IS AVAILABLE FOR THE WORK SPECIFIED, ui LO IN PAINT-EGGSHELL COLOR:WHITE AND SHALL NOTIFY ARCHITECT IMMEDIATELY IF SERVICE IS NOT ADEQUATE. 0 6. CONTRACTOR SHALL SUPPLY ALL GYPSUM BOARD CEILING ACCESS PANELS REQUIRED AND Or) < UPPER CABINETS TAFISA CRYSTALITE L474 BRUSHED NOTIFY ARCHITECT OF LOCATIONS PRIOR TO INSTALLATION.ACCESS PANELS SHALL BE AS MAIN ROAD (NYS RTE 25) ALUMINUM DEC.PANELS HARDWARE-EMTEK MANUFACTURED BY"INTEXFORMS INC.SIZE OF ACCESS PANELS SHALL BE COORDINATED IN SITE PLAN S62003SS 5.5"STAINLESS STEEL BAR PULL 3.5"CtC FIELD.ACCESS PANEL FRAMES SHALL BE TAPED AND SPACKLED.PROVIDE ANY AND ALL 201-011 INFORMATION ON EXISTING SITE PLAN BASED ON DEPT. OF BUILDING BLOCKING AS MAY BE REQUIRED. (2)GLASS SHELVES-TBD 7. CONTRACTOR SHALL SUBMIT SPRINKLER PLAN LAYOUT FOR APPROVAL BY ARCHITECT.ANY PROVIDED APPROVED DRAWING BY FRANK NOTARO ARCHITECT DATED z N, GLAllIO TILE#C11 4"x12"COLOR:MORNING MIST DEVIATION FROM PLAN DURING CONSTRUCTION MUST BE BROUGHT TO THE ATTENTION OF 1-29-1991 AND SURVEY BY YOUNG &YOUNG DATED 1-8-1991. \11,74=:= \Tf7­j=-\_W = A ARCHITECT IMMEDIATELY FOR APPROVAL. > CEASARSTONE COUNTER 8. CEILING HEIGHTS ARE DIMENSIONED IN RELATIONSHIP TO FINISHED FLOOR. LUCITE GLOVE DISPENSERS TBD .... ...... .... .............................. ........... ........... ................. 9. EMERGENCY LIGHTS SHALL BE INSTALLED ON SEPARATE CIRCUIT.REFER TO ENGINEERING SITE PLAN .............. ............. .............. o D Fci. ELKAY ELUH 1212 LAV W/KOHLER K-7509-CP FAUCET DRAWINGS FOR EMERGENCY LIGHT LOCATIONS.COORDINATE LOCATIONS WITH ............... ARCHITECTURAL REFLECTED CEILING PLAN,AND WITH ENGINEERING DRAWING FOR ......... ...... SOAP DISPENSER& LUCITE C-FOLD TOWEL HOLDER-TBD CAESARSTONE DESKTOP SWITCHING CIRCUITS AND FIRE ALARM SYSTEM. GREENO WC-4-TCSCH-L WASTE CHUTE/SHARPS 10. REFER TO ENGINEERING DRAWINGS FOR LOCATIONS OF NEW AIR SUPPLY AND RETURN AIR EXISTING I zi CONTAINER GRILLES. 7 7 77 VENT STACK P1-B.MOORE REGAL SELECT WATERBORNE __*� I..�.' -+- �( F - BASE CABINETS TAFISA CRYSTALITE L474 BRUSHED 11. ALL HORNS AND STROBES SHALL BE CENTERED ABOVE THE LIGHT SWITCH OR CENTERED ON INTERIOR PAINT-EGGSHELL COLOR:WHITE -7 -7 L.0 I SURFACE(WALL,COLUMN,ETC.)UNLESS OTHERWISE NOTED.ANY DEVIATION FROM THIS 471.1 ALUMINUM DEC.PANELSHARDWARE-EMTEK I JI ROOF INSTALLATION SHALL RESULT IN CONTRACTOR RELOCATING THE HORNS AND STROBES AT HIS(1)QUAD&POWER1DATA @ CL OF WORKSTATION 62003SS 5.5"STAINLESS STEEL BAR PULL 3.5"CtC --------------------------------------- --------------------------- ---------------------- -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- S \V OWN EXPENSE. @18'AFF.COORDINATE GROMMET. 12. ALL ABANDONED SLAB POKE THROUGHS FROM SLAB ABOVE SHALL BE FIRE SAFED AS ...... B1-WALL BASE-TBD-SIMILAR TO JOHNSONITE REQUIRED. 1-1--.-.--.--.r-,--------.--.-...-]--.-.-- -4 01 10.07.2016 ISSUED FOR FILING 3-41' 2'-6" 2'-6. VINYL MILLWORK BASE 13. SEE ENGINEERING DRAWING FOR LOCATIONS OF EMERGENCY LIGHTING IN OPEN AREAS, 2'-6" 2'-6" REV DATE DESCRIPTION SWITCHING CIRCUITS AND FIRE ALARM SYSTEMS 14. EXISTING LIGHTING TO BE TIED-IN TO NEW PANELS.REFER TO ENGINEERING DRAWINGS f 112" 1: i.), 1: i/i:D' 2" 1 1' 1I2 11 1/2 11 1/2" 1: 112- Onvironeficss EXAM ROOM MILLWORK ELEVATION 15. PROVIDE EXPANSION JOINTS IN GYP.BID.SOFFIT AND FASCIAS.EXPANSION JOINT TO BE 2'1 Designing EnAronments 7bat Work. SCALE: 3/8" 1'-0" 'PITTCON''U'SHAPE,TAPED AND SPACKLED AT 25 FEET ON CENTER MIN. AIR Environetics Architects, P .C. 116 East 27th Street t 212 679 8100 Pi-B.MOORE REGAL SELECT WATERBORNE New York,NY 10016 f 212 685 9044 INTERIOR PAINT-EGGSHELL COLOR:WHITE 1 1/2' av av V ;...ckv av I av I av tav (�­. Environetics.All Rights Reserved. ....... _-1 I Copyright @ by ... ........ UPPER CABINETS TAFISA CRYSTALITE L474 BRUSHED ........ PROJECT NO.: E2623 ..................... =T Lav Lckv i ALUMINUM DEC.PANELS HARDWARE-EMTEK LAB VACUUM AS SPECIFIED I wc wc S62003SS 5.5"STAINLESS STEEL BAR PULL 3.5"CtC j J_11 J J_ L_ FUME CONTAINMENT HOOD r .:;.:;r.. .. .............At SCALE: AS NOTED ........... 7 FIRE RESISTANT SAFETY CABINET AS SPECIFIED ii 112 11112 1/2T I ELKAY ELUH1 212 LAV W/KOHLER K-7509-CP FAUCET 012 2- FIRST FLOOR DRAWN BY: KB SOAP DISPENSER& LUCITE C-FOLD TOWEL HOLDER-TBD -------------------------------------------------------------- ---------------------------- _______}_______W-___..__ ------------------------------------ -------------- --------------I.............................. ----------- ............------------ •- ------ ------------------- ---------------------- I AN - -TCSCH-L WASTE CHUTE/SHARPS CHECKED BY: KB GREENOWC-4 40 4# CONTAINER 1 112' 1 112' JI ___'j -------------- ----z----------------------------- --- DRAWING TITLE: (1)SEPARATE CIRCUIT 120V GFI @ CL 18'AFF- LINISTAIN AUTOMATIC SLIDE STAINER ................. .......................! I \ C.0. .......... �XIST, EXIST� EX:S� EX::S':.STAF� CRYOSTAT 4 EX:S^r. E.X. EX::S DR. E`S�, 6� : ................... COVER SHEET ............::...< ................... ... :0:-: ....... ................ ........... .......... T *""'* 7 '2 1:;:!-* RM RM ............ w............. .. E.X-AIM E-X-A-k1 RM11', ...........-i E'V MR M,3 AN�RY E 'N'l RW'i ADA RESTRN' ................. GLAZZIOTILE#C11 4"xl 2"COLOR:MORNING MIST NEW EXAM NEW MOH LAB ................................ ................................ ......... ..... ....................... .................................... .......... ........... -E -0 CHANGE NO CHANG� ROOM#5 N 0 C H A N IN NO CHAN"E NOCHANGE NO CHANGE NO CHAN-E NO CHAN"E ............. (1)QUAD @ CL OF MILLWORK @44'AFF. ......... .............. ......... ......... ....... ............... ................ ... ... ............... I : - COUNTERTOP ARBORITE STYLE P31 1-CA COLOR: WHITE XABIA FINISH:HPL FRESH AIR BASEMENT 7 7 BASE CABINETS TAFISA CRYSTALITE L474 BRUSHED --------------------------------------------II� ------------------------------------------------------------------------------------------------------------------------- -------------------------------------------------------------------------------- ------ ALUMINUM DEC.PANELSHARDWARE-EMTEK P1-B.MOORE REGAL SELECT WATERBORNE S62003SS 5.5"STAINLESS STEEL BAR PULL 3.5"CtC ZO ALL PLUMBING SHALL BE DRAWING NUMBER: INTERIOR PAINT-EGGSHELL COLOR:WHITE L . ...... BI-WALL BASE-TBD-SIMILAR TO JOHNSONITE C, INSTALLED TO CODE. PLUMBING VINYL MILLWORK BASE CONTRACTOR SHALL PAY ALL 4' FEES & FILE ALL PERMITS. T- 100.00 A,, TOLOG -X IG TPAKING PACE ISTI, 2'-6- 2'-6" 7-6" 2'-1'4" HOUSE TRAP SHEET SET NUMBER 01 OF 3 SHEETS 2 MOH'S LAB ELEVATION 1 3 MOHIS LAB ELEVATION 2 PLUMBING RISER DIAGRAM SCALE: 3/8"= 1'-0" SCALE: 3/8"= V-0" REFLECTED CEILING PLAN LEGEND r- - - - - - -- - - -- - - - - - - - - - SYMBOL DESCRIPTION ,fio .. 1111:::: :: .: _1111. .. w zcn i:. /'.. .... ._ ... RDINATE F R ;,. r: ............ ... ... SHADED AREA IND S KATE NO INTENDED WORK T _...._.... 1111 ._. _. 1111 .. .. 0 POSS BLE .1111 . : : ...... ,".::' .. ..... . ;1111; :<,°:: G C 0 C00 .11::1::1:: . . N .1111.. . 1111 .::;. :: .11.1 .. � " L ' Gtt ' I. ::�::::::: :: E SHADED AREAS. . , .. - .. 1111.... . ,1111... .. :. ..... ........................ . .. 1111.... _.. _.. _.:. : -.. ..:<. .: 1111 .. ;. .;.'.>.. 1111:;. ,:. 1111 1111 .. .. ... .. 1111. .. _ .. .. _. .. :. ::: .. , ROOM OR SPACE NAME REQ" ----------- IF-31/21 XX Ir 0 ---- U------0 0 L2 A ID I LL I L2 A T-1 0 ROOM OR SPACE NUMBER r::;: .:: I : :,': :..;... 1111 I I I. I '111;1:;>::« ,111 1,€: _1111.:_:_ :;>, :. € o f --1 I I CEILING HEIGHT XI T - J E S EXIST. XI TIN S G CORRIDOR0 - BULL DOVYN IiKi I CEILING MATERIAL: 31/2 I I I X'X" CLIENT: EXIST. % EXIST. EXIST. EXIST. _ TTIC ST IR NE ACT-1 ««: EXIST. _ CAN XAM RM STAFF € EXAM R L J 0 REMA I L2 I ( ACT=BLDG.STD.ACOUSTICAL CEILING TILE M RM >>: »:: L i1 CATV CATV I GYP=e"THK.GYPSUM BOARD CEILING F C . #2 RM #1 L1 N LAB S NO CEILING,EXISTING IN C G ST NG LAB T BE PATCHED PAINTED L - 312 S 0 C & 2ZIcn - . cn _ €DIST. I a _ , II _ _ __ _ _ I- - ,. vs cn c-cnn - L - - AET - - II ( - CEILING GRID HEIGHT OR MATERIAL BREAK.GC SHALL PROVIDE GYPSUM BOARD FFI E AND RE EPI �I 0 C C TON I I� I I HEADER AND FASCIA BETWEEN CEILING HEIGHTS. «: u I E E I ; 1111::: 3 /2 :. C 1 RECESSED WALL MOUNTED LIGHT SWITCH.8"FROM DOOR TO CENTERLINE OF FIRST ROCKERSWITCH . C LIGHT WITH HALL R ERIE SWITCH S BE LUTRON MAESTRO SERIES,COLOR WHITE CONSULTANT : E:. a. <: _' N -_ I ;:z;:: ;1111. x;: NEW ,1111: 1111.. L X AU 1 7� :� �o I UNLESS OTHERWISE NOTED. NOTE: ALL LIGHT SWITCHES IN PRIVATE OFFICES SHALL - 3 ( 2 FM "c+� N V T OC RRID R CO 0 8 3 z 1 BE WALL MOUNTED OU OCCUPANCY SENSOR TYPE REF ENGINEERING D 0 i EF C S SO ER TO E G RAWING S . I ­1 _____� I I � ' EXIST. OOD I FOR ADDITIONAL INFORMATION AND SPECIFICATIONS. 1 - _ :::.. I. O - - "" - I S STANDARD LIGHT SWITCH _,... (3 PRIVATE FI SE 1 F I I �EXISTING� I I EXISTINL/ G I I EXISTING I ( TOILET RM I 0I D-DIMMING SWITCH CATV I OS-OCCUPANCY SENSOR 2 �N III II II II II II EXI T. S KYLI HT KYLIGHT I S KYLIGHT S G S L R- 0 OVERRIDE SWITCH � 4 ' O S TC ;1;.-I...*. 11' :<::, - :' :::; ° :<:. ,1111<.. C 5 O r, O I I I ABOVE I I CORRIDOR I I ABOVE I I I I ABOVE I I I L1 1111: ;:>:: 0 I 1 0 I I I I DENOTES I - -- -- OT S L GHT FIXTURE TO HAVE EMERGENCY BATTERY BACKUP POWER TO I I I I C I r r r EM % COMPLY W/LOCAL CODES THIS LIGHT FIXTURE SHALL BE ON A SWITCHED CIRCUIT NEW �I 67�� 1111.;.. .;.. .::.:;.::. >. - 1 1111,.: �. .. .. .. 1111 .:: . 1111. . ... EXAM RM _ 1111.. .: .. 1111: 1 1 C 5 ... . .. #5 CATV I �: - _ I NEW € 11 - - J.i.'.': 7VFNEW 2'X 2'ACOUSTICAL CEILING GRID AND TILE:(ACT-1): 144" FF I I _Eff ISN 1GF1 I I I I I MOBS ,:. I IST. t f tr 'a a ARMSTRONG,HEALTH ZONE,OPTIMA#3216,9/16"SQUARE TEGULAR W/9/16" �G� I`�' i i I EXIST. Com' i EXIST. >s 30 PARTIAL REFLECTED CEILING PLAN SILHOUETTE XL1/8"REVEAL GRIDS Z�� �R O M 1 I 14"A F E I EXAM RM `� „;_ V -4p- ° 1`= «1.'. : >::: F 1 ` Z SCALE: 1/4"= 1'-0" � , - 77 ' ;1111<: ... :.. 1111 I - - FI 1 I OFFI E #3 i z €<:::: ;,11.11,...* I - 1 :€ �C r _ ..I___ 1 I IS EXIST. 111 ..., , I © ® i 10 I I i 1 ` M WAITING ROOM3: ❑ } rte; ;I�'41 t Z �5LIGHT FIXTURE SCHEDULE I ; .:Lj1 t\ m w � ;� I I I o' I 0= <' �: r O - -J-- EXIS I z v> �' f - I I �S V v J M I IVA 011 LAMPS iv Q� T ET RM :O TYPE SYMBOL DESCRIPTION I MANUFACTURER CAT.NO. REMARKS �� * S� O SE I1W VOLTS # TYPE W . I . I A � CAB . 1111.: . 1. .;: -:: .111... :..,.... ..... .1111. ..... .... .... ..L. .. PROVIDE EMERGENCY PACK WHERE :. :,:. - - I 4 RECESSED LED LIGHT FIXTURES TDJALED 2X4-LTGX 3500K ........ :... : .... " ` L1 DJA LED SERIES VOLTAGE, IF-T/SG-DB-VRB VIF - HALF SHADED FIXTURE CORONET,T E V DENOTED BY . : U ITH AN E VV °., 'r mss,' I 9'-3Z" 7,_�" 0 \) : .::::: I L_ EXISTING FINISHES AND MILLWORK TO BE PROVIDE EMERGENCY PACK WHERE I '.- 2X2 RECESSED LED LIGHT FIXTURES TDJALED-2X2-LTGX-3500K- - - - - - -- -- - - - - - - - - -- -- - - - -- - REMOVED AND REPLACED WITH L2 CORONET,TDJA LED SERIES VOLTAGE,VIF-T/SG-DB-VRB VIF - DENOTED BY HALF SHADED FIXTURE r.<: AREA OF NEW INTERIOR SCHWEIGER STANDARDS AS WITH AN'E' NON-STRUCTURAL PARTITIONS AND INDICATED-TYP. f DOORS EXIST. FOYER - SHADED AREA DESIGNATES RECESSED EDGE LIT LED EXIT SIGN ESH7-2 ILLUMINATED FACE(S).ARROW(S) I EATON,SURE LITES ES SERIES EST7-2-WH-R-C INDICATE DIRECTION TO EXIT-REFER �`., :' •1: 0 MAIN ROAD TO PLAN. � 'Fp 1 .. 3 ... tl'. / r ".' B1-WALL BASE-TBD-SIMILAR TO JOHNSONITE VINYL MILLWORK BASES ­� P1-B.MOORE REGAL SELECT WATERBORNE INTERIOR PAINT-EGGSHELL CC °' `" "' - ° "' - - WHITE - - - - - - - r - *�*cn cn Q - I P2-B.MOORE WATERBORNE SATIN IMPERVO PAINT-SATIN COLOR:WHITE LPF1 -MIDWOOD FLOORS MGL8002 3.5"Lx48"L COLOR:CANYON OAKI ­­ P I (D :: PL1-TAFISA CRYSTALITE L474 BRUSHED ALUMINUM DECORATIVE PANELS P , PL-2-COUNTERTOP-ARBORITE STYLE P311-CA COLOR:WHITE XABIA FINISH: 0 NEW 2 e I TL1 -GLAZZIO TILE#C11 4"x12"COLOR:MORNING MIST CORRIDOR I . 1 CONSTRUCTION AND POWER/DATA PLAN SS1 -CAESARSTONE STYLE:2141 COLOR:BLIZZARD I �.. ti - v SCALE: 1/4"= 1'-0" HARDWARE-EMTEK S62003SS 5.5"STAINLESS STEEL BAR PULL 3.5"CtC '``` . :... .. :.:.:.... :.,. ........:. ':.:.. .. .:::::.... :..:..::.;1111 - �,,' 0 CONSTRUCTION PLAN NOTES WALL TYPES HARDWARE SCHEDULE I 2 CONTRACTOR SHALL REBUILD ANY PERIMETER WALLS AS TIGHT AS POSSIBLE TO I 0 I ` Q r 1. REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION& SPECIFICATIONS. 20. ANY EXISTING PLUMBING RISERS.PLASTER OR LAMINATE WITH 5/8"GYP.BD. SYMBOL DESCRIPTION I I - 0 Z q. 2. CONTRACTOR SHALL VISIT THE JOBSITE TO FAMILIARIZE HIMSELF WITH THE 21. ALL METAL STUDS SHALL BE 20 G.A.AND SET AT 16"O.C.FROM SLAB TO SLAB, ALL HARDWARE T'0 RECEIVE#626 SATIN CHROME FINISH,LION. 3 4 5 6 7 I .qqI NEW Z EXISTING CONDITIONS AND THE GENERAL SCOPE OF WORK.ANY EXISTING ITEMS UNLESS OTHERWISE NOTED. NON RATED FULL HEIGHT PARTITION WITH INSULATION: _ I EXAM RM I I F<. Z Y H-1 HINGE STANLEY„#4.5 X 4.5#F6B179 BALL BEARING HINGE,(2)PAIRS : _ AND/OR CONDITIONS NOT SHOWN ON THESE DRAWINGS OR THOSE THAT FOLLOW, ® ® ® O I 1 #5 I P U 22. NEW GYPSUM BOARD CONSTRUCTION MEETING EXISTING CONSTRUCTION IN THE 3 5/8"METAL STUDS 20 GA.AT 16"O.C.W/ONE LAYER OF 5/8"THK TYPE I - 1 NEW e2 I `;,,.,,.<:_ Q � AND/OR ARE INFERRABLE AND NECESSARY TO BE REMOVED OR MODIFIED,SHALL SAME PLANE SHALL BE FLUSH WITH NO VISIBLE JOINT SHOWING. REMOVE EXISTING XP GYP.BD.(NATIONAL GYPSUM,GOLD BOND)ON EACH SIDE FROM L-1 PASSAGE LATCHSET-SCHLAGE,SID W/SATURN LEVER ® I LPF P I MOH'S 2 H BE DONE SO WITHOUT ANY ADDITIONAL TIME AND/OR EXPENSE TO THIS CONTRACT. CORNER BEAD WHERE REQUIRED. 1 SLAB TO SLAB ABOVE. TAPED AND SPACKLED. LK 1 ENTRANCE LOCKSET-SCHLAGE,S51 W/SATURN LEVER I i 1 1 1 i LqB I � 3. ANY DISCREPANCY IN THE CONTRACT DOCUMENTS MUST BE BROUGHT TO THE TED T PROVIDE BY OTHER FURNISH AND IN TALL PROVIDE MIN.2"THK THERMAL SOUND MOLD&MILDEW RESISTANT ® I I I - I '.; o UNLESS OTHER WISE NO 0 0 S,GC TOS _ "t Q ATTENTION OF ARCHITECT.FAILURE TO DO SO MAY RESULT IN REDO OF FINISHED DOOR SCHEDULE I I M 23. ALL SCHEDULED HARDWARE,FIXTURES AND DEVICES INCLUDING ALL REQUIRED FIBER GLASS INSULATIONS(JM,MR FACED OR APPROVED EQUAL) LK-2 STORAGE LOCKSET SCHLAGE,S80 W/SATURN LEVER ® I I ® I � r WORK THAT DOES NOT ADHERE TO THE INTENT OF THE CONTRACT DOCUMENTS. I i PL-1 STEEL SUPPORTS,METAL BRACING,HANGERS,CARRIERS,BLOCKING AND BACKING FULL HEIGHT BETWEEN STUDS. A-1 SILENCERS-IVES(3)PER DOOR 4. DO NOT SCALE THE DRAWING.USED FIGURED DIMENSIONS ONLY.LARGE SCALE IN ORDER TO COMPLETE SUCH INSTALLATION AND/OR CONSTRUCTION. NOTE: I I SS 1 TL-1 1 1 TYP MAT THICKNE FRAME I ® I PL-1 1 (� DETAILS GOVERN OVER SMALL SCALE.ARCHITECT SHALL BE NOTIFIED OF ANY ALL TAPE&SEALANT MUST BE MOLD&MILDEW RESISTANT PRODUCT. A-2 STOP-ROCKWOOD,#RM850 ® ® ® ® WIDTH HEIGHT RATING REMARK I 1 I DISCREPANCIES ON THE DRAWINGS. E L. SS TYPE 1 I PL-2 I 5. COORDINATE ARCHITECTURAL DRAWINGS WITH MECHANICAL,ELECTRICAL, 24. GC IS RESPONSIBLE TO PROVIDE ALL TEMPORARY LIGHTINGS,FIRE A-3 CLOSER-LCN,40'10T SERIES ® I TL-1 - --I-- PLUMBING,AND SPRINKLER DRAWINGS. ALARMS/STROBES,EXTINGUISHER,EXIT SIGNS,SPRINKLER,SMOKE DETECTORS& CONSTRUCTION PLAN LEGEND C WD 3'-0" 6'-8" 1314" A3 I LPF P " I EMERGENCY KIT DURING CONSTRUCTION. A-4 FLUSH BOLTS-ROCKWOOD,#2845 1 1 1 6. ALL WORK SHALL BE EXECUTED IN A CLASS W MANNER AND SHALL NOT BE SIGNED 25. GC RESPONSIBLE TO PROVIDE MOISTURE RESISTANT INSULATION AND GYP.BD. D WD 2'-8" 6'-8" 13/4' A3 OFF UNTIL ACCEPTABLE TO OWNER. AND/OR CEMENT BD.FOR ANY SCHEDULED PARTITION WITH NEW PLUMBING A-5 COAT HOOK,ROC'KWOOD,#RM802 I >;.: I. 7. ALL INTERIOR CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE CODES AND SYMBOL DESCRIPTION «_ '" FIXTURE AND WATER LINES. FIXTURES ;1111: <., .'Q� ::::. N E IN E LOCATION F WORK.CORRIDORS AND ALL OTHER ORDINANCES IN PLACE TH LOC 0 0 0 26. IR T AN ::,1111::,_:::::::: ; ;;11;11 : s: :11'.1.1. I.,.: ::: ` :i«. €€' >>€ ,:'€ F ESTOP ANY SLAB OPENINGS,PA CH,LEVEL D PREP FLOOR AND/OR DOOR / FRAME TYPES I ECT PRIOR THE FABRICATION F - CLEARANCES SHOULD BE CHECKED WITH ARCHITECT 0 SURFACES(WITHIN ENTIRE AREA OF WORK)TO RECEIVE SCHEDULED NEW SHADED AREAS INDICATE AREA OF WORK NOT IN CONTRACT(NIC). "`' ` -_ ;... ..:::. ::.::._1111.:. . ( ) I . . . . ANY WORK.CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING SAME AT FINISHES. COORDINATE W/ENGINEERING DOCUMENTS FOR POSSIBLE ROUTING u :1[:: HIS/HER OWN EXPENSE. 27. GC RESPONSIBLE TO X-RAY CONCRETE FLOOR SLAB&SUBMIT REPORT TO OF SERVICES THROUGH THESE SHADED AREAS. 2" SCHEDULED I [Or8. ALL CONTRACTORS PERFORMING WORK IN THIS BUILDING SHALL APPLY FOR THE BUILDING MANAGEMENT FOR REVIEW&APPROVAL BEFORE CORE DRILL FOR ANY FPARTITION "RULES AND REGULATIONS FOR TENANT ALTERATIONS"WITH THE BUILDING SCHEDULED PLUMBING AND/OR POWER/DATA PENETRATIONS. _, PARTIAL FINISH PLAN MANAGER'S OFFICE AND CONFORM ACCORDINGLY. 28. ALL CUSTOM MILLWORK SUCH AS WOOD DOORFRAME,FURNITURE&CABINETS 5/8"THK GYP.BD. SCALE: 1/4"= 1'-0" 9. ALL ROUGH CARPENTRY WOODWORK SHALL BE TREATED FOR FIRE RETARDATION INCLUDING ANY SUBSTRATES MUST BE FIRE RETARDANT&PREMIUM GRADE HDF EXISTING WALLS OR COLUMN ENCLOSURES TO REMAIN. WITH U.L.APPROVED MATERIAL.FLAME SPREAD RATING NOT TO EXCEED 25. OR MDF BOARD OR PLYWOOD,U.O.N. w 10. ALL THERMAFIBER SOUND ATTENUATING BLANKETS SHALL BE A MINIMUM OF 2"thk 29. INSTALL CONTROL JOINTS ON DRYWALLS&GYP.BD.CEILING AS REQUIRED TO I > DOOR & HARDWARE NOTES (CONT.) FOR 21/2"STUDS,4"thk FOR 3 5/8"&4"STUDS AND 6"thk FOR 6"STUDS UNLESS PREVENT ANY WALL/CEILING CRACKS. LOCATIONS AND QUANTITIES TBD W/ 01 10.07.2016 ISSUED FOR FILING OTHERWISE NOTED. PROVIDE FOIL BACKING FOR ANY"WET"LOCATIONS OR ARCHITECT IN FIELD. r EXISTING CONSTRUCTION, DOORS AND FRAMES TO REMAIN. REV DATE DESCRIPTION EXTERIOR WALL. �v N BLOCKING 11. GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATING AND CONFIRM ALL LOCKING,LATCHING AND KEYING 11. CONTRACTOR RESPONSIBLE TO FURNISH&INSTALL NEW ACCESS DOORS CONSTRUCTION PLAN KEY NOTES V PROVIDE ALL REQUIRED REQUIREMENTS WITH THE LANDLORD/BUILDING MANAGEMENT AND THE TENANT USE PRIOR TO PURCHASE AND nvi rove f ics® (STEALTH,LOCATION&QUANTITY VARIES)ON DRYWALL AND/OR GYP.BD.CEILING BLOCKING W/METAL INSTALLATION. Designing®®E �w WHEREVER REQUIRED BY BUILDING MANAGEMENT TO ACCESS&MAINTENANCE TRUDOOR APPROVED EQUAL NOTE: STUDS 12. GENERAL CONTRACTOR AND THE HARDWARE SUPPLIER SHALL THOROUGHLY REVIEW ALL THE DEMOLITION, CONSTRUCTION, POWER SYM NEW DOOR. REFER TO DOOR SCHEDULE FOR DETAILS AND That WorV- ANY VALVES&CONTROLS FOR PLUMBING,ELECTRICAL,HVAC,SPRINKLER&ETC DESCRIPTION7 CORNER BEAD BOTH PLANS & DOOR SCHEDULE. FURNISH ALL DOOR AND PROPER HARDWARE FOR ALL OPENINGS WHETHER LISTED OR NOT. COMPLETE AIR E n v i r o n e t i c s Architects, P.C. BOL SPECIFICATIONS. SEE DOOR SCHEDULE FOR SIZE. USE KD FRAME FOR ALL NON-RATED SYSTEMS. SEE ENGINEER DRAWINGS FOR MORE INFO. SIDES.(TYP) SHOP DRAWINGS TO BE PROVIDED FOR APPROVAL PRIOR TO PURCHASE. 116 East 27th Street t212679 8100 EXISTING CARPETING TO BE REMOVED IN ITS ENTIRETY AND SUBFLOOR PREPPED SOLID CORE WOOD DOOR. PARTITIONS&WELDED FRAME FOR ALL New York,NY 10016 I212 685 9044 ANY EXPOSED FLOOR OR CEILING SLABS TO BE PATCHED,LEVELED AND PREPARED O COLOR WHITE TO MATCH WALL RATED PARTITIONS 13. ALL DOORS UP TO T-6"OR ABOVE SHALL BE PROVIDED WITH MIN.2 PAIR OF HINGES. Copyright© by Environetics.All Rights Reserved. 12. TO RECEIVE SCHEDULED NEW FINISHES.REFER TO REFLECTED CEILING PLAN FOR FOR NEW FLOORING AS SCHEDULED.REFER TO FINISH PLAN AND LEGEND 14. ALL WOOD VENEER DOORS TO BE SOLID CORE, UNLESS OTHERWISE NOTED. EXPOSED SLAB AREAS,AND REFER TO FINISH PLAN FOR FINISH SPEC. 00 DOOR TAG WOOD DOOR GYP. BD. OPENING HOLLOW METAL FR. 15. ALL WOODWORK DOORS 8'-0"OR HIGHER SHALL BE MINIMUM OF TWO(2)INCHES THICK. PROJECT NO.: E2623 EXISTING CEILING TILES,GRID,AND LIGHT FIXTURES TO BE REMOVED IN THEIR X X 13. CONTRACTOR TO SUPPLY AND INSTALL 3/4"F.R.BLOCKING OR APPROVED METAL ENTIRETY WITHIN THE AREA OF WORK AS INDICATED.REFER TO REFLECTED DOOR SEE DOOR&HARDWARE SCHEDULE FOR MORE INFO AND WORK SCOPE D A2 A3 16. GC TO VERIFY EXISTING CONDITION AND COORDINATE WHERE RECESSED FLOOR CLOSERS/PIVOTS TO ENSURE PROPER SCALE-NTS SCALE-NTS SCALE-NTS SCALE: AS NOTED FLAT STOCK BEHIND ALL GYP.G.C.SHALL COORDINATE WITH MILLWORKER FOR 0 CEILING PLAN AND SCHEDULE FOR NEWACOUSTICAL TILES,GRID AND LIGHT HARDWARE CLEARANCES/DEPTHS. REQUIRED LOCATIONS&ADEQUACY OF BLOCKING REQUIREMENTS AND PROVIDE FIXTURES. 17. GC TO PAINT(SEMI GLOSS) FOR ALL HOLLOW METAL DOORS AND FRAMES TO MATCH ADJACENT WALL FINISHES, UNLESS OTHERWISE DRAWN BY: KB ALL SUCH BLOCKING PRIOR TO CLOSING UP ANY AND ALL WALLS,COLUMNS,ETC. CUSTOM MILLWORK AND NEW CABINET FURNISH AND INSTALL BY G.C. DOOR & HARDWARE NOTES NOTED. CHECKED BY: KB TO MEET SUCH REQUIREMENTS.SEE FURNITURE AND MILLWORK SHOP DRAWINGS EXISTING DOOR AND FRAME TO BE REMOVED IN THEIR ENTIRETY AND OPENING OR AS SPECIFIED ON DRAWING. SUBMIT SHOP DRAWINGS FOR REVIEW 18. GC TO PROVIDE GYP.BD.HEADER INCLUDING BLOCKING FOR ALL SCHEDULED FRAME-LESS GLASS/HOLLOW METAL/WOOD DOORS. FOR ALL FIXTURE INFORMATION. � INFILLED AND PATCHED TO ALIGN WITH ADJACENT WALL CONSTRUCTION.FINISHES ® &APPROVAL PRIOR FABRICATION. 1. THE CONTRACTOR SHALL PROVIDE ALL SPARE KEYS TO THE BUILDING MANAGER AND CLEANING PERSONNEL AS 19. ALL DOOR FRAMES TO BE CAULKED TIGHT TO WALL.CAULK SHALL BE PAINTABLE AND PROVIDED BY GENERAL CONTRACTORS SUB. DRAWING TITLE: 14. CONTRACTOR SHALL SUPPLY SPECIFIED(RECESSED)FIRE EXTINGUISHERS AS PER FINISH SCHEDULE AND PLAN. REQUIRED. GC TO PROVIDE AND COORDINATE WITH BUILDING MANAGEMENT AND/OR LANDLORD FOR ALL 20. ALL SINGLE DOORS WITH SECURITY SHALL BE PROVIDED WITH ARMORED STRIKE PLATES ON THE ENTRY SIDE ON THE DOOR. ALL GROUND FLOOR CABINETS.LOCATION OF EXTINGUISHERS AS REQUIRED BY LOCAL AUTHORITY. ® EXISTING DOOR AND FRAME TO BE REMOVED AND OPENING TRIMMED OUT OR MASTER KEYING REQUIREMENTS AND STANDARDS. DOUBLE DOORS WITH SECURITY SHALL BE PROVIDED WITH A FULL HEIGHT ASTRAGAL ON THE ENTRY SIDE OF THE DOOR. REPAIRED WHERE INDICATED ON PLAN 21. PROVIDE DOOR SILENCERS MIN.5 FOR EACH SCHEDULED WOOD OR HOLLOW METAL DOOR FRAME. CONSTRUCTION Et 15. FILL AND FIRESTOP ANY EXISTING CORE DRILLED HOLES LEFT UNUSED IN THE 2. ALL DOOR HARDWARE,DEVICES,PARTS&ACCESSORIES MUST BE COMMERCIAL GRADE,HIGH TRAFFIC USE AND 22 GENERAL CONTRACTOR MUST NOTIFY ARCHITECT IF THERE ARE ANY DISCREPANCIES AND/OR CONFLICTS BETWEEN THE POWER/DATA PLAN, PART. FLOOR SLAB AND CEILING SLAB. HVAC CONTRACTOR IS TO COORDINATE REMOVAL AND RELOCATION OF FLOOR HEAVY DUTY TYPE WITH ADJUSTABLE OPTIONS. CONTRACTOR TO SUBMIT DOOR SHOP DRAWINGS AND ALL 16. GC RESPONSIBLE TO PATCH&REPAIR ANY EXISTING SURFACES THAT DAMAGED BY 0 REGISTERS TO ENSURE PROPER COOLING AND HEATING REQUIRED PER ROOM. DOOR HARDWARE SUBMITTALS TO ARCHITECT FOR REVIEW AND APPROVAL PRIOR ORDERING. CONSTRUCTION DOCUMENTS AND/OR EXISTING FIELD CONDITIONS BEFORE PURCHASE OR START OF WORK. GENERAL CONTRACTOR REFLECTED CEILING PLAN, CONTRACTORS DURING CONSTRUCTION. 3. ALL HARDWARE TO BE AS SPECIFIED OR APPROVED EQUAL BY ARCHITECT. IS RESPONSIBLE TO REPAIR AND/OR REPLACE ANY AND/OR ALL ITEMS DUE TO LACK OF NOTIFICATION OR COORDINATION WITH THE PART. FINISH PLAN ELECTRICIAN IS TO VERIFY EXISTING ELECTRIC PANELS AND ELECTRICAL SERVICE 4. ALL HARDWARE TO BE INSTALLED ACCORDING TO THE STANDARDS OF THE SPECIFIED MANUFACTURES USED. ARCHITECT. 17. LAMINATE AND OR PLASTER ALL EXISTING EXPOSED CORE WALLS AND PERIMETER 6 PROVIDED TO THE BUILDING TO ENSURE IT IS ADEQUATE FOR NEW EQUIPMENT 23. UNLESS OTHERWISE NOTED, GC IS RESPONSIBLE TO PROVIDE INTERCHANGEABLE CORES FOR ALL SCHEDULED LOCKSETS WITH A SCHEDULES Et NOTES COLUMNS AND WALL SURFACES WHICH ARE DAMAGED OR MISSING WITH ONE NEW O 5. ALL LOCKSET/LATCHSET LEVERS OR PULLS TO BE 3'-2"A.F.F TO CENTERLINE,UNLESS OTHERWISE NOTED. MINIMUM OF TWO(2)KEYS PER CORE AND THREE(3)MASTERS.COORDINATE WITH THE TENANT AND THE BUILDING MANAGEMENT FOR LAYER OF GYPSUM BOARD.SHIM AS REQUIRED. AND 220V RECEPTACLES IN EACH EXAM ROOM. 6. ALL DOORS DESIGNATED TO BE FIRE RATED SHALL BE LABELED AS SUCH AS REQUIRED BY CODE. DRAWING NUMBER: 7. ALL FIRE RATED METAL DOOR FRAMES(IF ANY)TO BE WELDED TYPE UNLESS OTHERWISE NOTED. ALL FINAL REQUIREMENTS. 18. FIRESTOP AND FIRESAFE ALL EXISTING DEMISING PARTITIONS(IF ANY),CORE ELECTRICIAN IS TO TRACE BACK TO SOURCE AND DISCONNECT ALL RECEPTACLES 24. GC IS RESPONSIBLE TO VERIFY ALL EXISTING AND/OR NEW WALL OPENING DIMENSIONS INCLUDING WALL THICKNESS AND CEILING WALLS,ETC TO MEET REQUIREMENTS OF FEDERAL,STATE AND/OR NYC BUILDING 7 THAT ARE NOT TO BE USED ACCORDING TO THE NEW EXAM ROOM AND MOH'S LAB 8. ALL DOORS AND HARDWARE TO COMPLY WITH COBA/ANSI STANDARDS LATEST EDITION. A _ 1 00 00 O 9. PROVIDE 1/2" UNDERCUT FOR ALL DOORS WITH SCHEDULED FLOOR FINISHES. MIN. 3/4" UNDERCUT FOR DOOR HEIGHTS BEFORE FABRICATE ANY SCHEDULE DOOR AND FRAME. A 1 . DEPARTMENT CODE. LAYOUT.EXACT PLACEMENT OF RECEPTACLES AS PER DRAWINGS. 25. FOR ANY EXISTING DOOR LABELED TO RECEIVE AND/OR TO REPLACE WITH NEW HARDWARE AND/OR SECURITY DEVICES,CONTRACTOR EXISTING SKYLIGHT IS TO BE REMOVED AND HVAC CONTRACTOR IS TO PROVIDE A 10. GENERAL CONTRACTOR SHALL PROVIDE ALL HARDWARE FITTINGS AND ACCESSORIES AS REQUIRED FOR 19. CONTRACTOR SHALL BE RESPONSIBLE FOR THE FINAL CLEAN UP OF THE ENTIRE ABOVE STONE SADDLE. IS RESPONSIBLE TO MODIFY EXISTING DOOR AND/OR DOOR FRAME TO ACCOMMODATE SUCH NEW HARDWARE AND/OR DEVICES. SHEET SET NUMBER 02 of 3 SHEETS PREMISES,TO INCLUDE,BUT NOT LIMITED TO,FLOORS,MILLWORK,FIXTURES,ETC, WATERPROOF VENT CAP UTILIZING THE EXISTING CURB,FLASHING ANDSPECIFIC INSTALLATION AND ANY SPECIAL ITEMS REQUIRED FOR CODE COMPLIANCE AT THESE DOOR 26. UNLESS OTHERWISE NOTED TO PROVIDE BY OTHERS, GC IS RESPONSIBLE TO FURNISH AND INSTALL ALL REQUIRED DOOR, FRAME, FOLLOWING THE INSTALLATION OF MILLWORK,TO THE SATISFACTION OF THE ® WATERPROOFING.200CFM ROOM EXHAUST FAN AND EXHAUST FROM FILTERED LOCATIONS. GENERAL CONTRACTOR SHALL COORDINATE WITH HIS SUBS AND MANUFACTURER TO INCLUDE ALL DOOR HARDWARE&DEVICES INCLUDING ALL SCHEDULED SECURITY HARDWARE AND DEVICES. OWNERS REPRESENTATIVE. VENT HOOD REQUIRED BY THE NEW MOH'S LAB ARE TO BE DUCTED TO THIS VENT ITEMS AND COST REQUIRED. 27. GENERAL CONTRACTOR MUST COORDINATE AND CONFIRM LEAD TIME WITH ALL DOOR AND HARDWARE MANUFACTURER BEFORE ENCLOSURE AND OUTSIDE CONSTRUCTION. .......... REFLECTED CEILING PLAN KEYNOTES REFLECTED CEILING PLAN LEGEND :. . :.: .. . <: E SYMBOLDESCRIPTION.. ;:.: STING.... ..... ... TO:REMAII� " "`" REPAIR EXISTING WATER DAMAGED GYPSUMCEILINGc'� �' � �.'� '�`:� �' �"''� '� . S ,.. HADED AREAS INDICATE NT DI "` ...... ..... .. . . __ . _. _... ... _... _... .. _. _:.:..... .. .. ... C NO INTENDED WORK.G.C.TO COORDINATE FOR POSSIBLE GROUP BDERMATOLOGY 51 �:::: v<'. @:? �x <.`:;< ....... ..... .... .. .. .;.x::::.:;:i%::::.iii:::%g"::.::i": :>:g...:>r::.'i::<: Ei:;. :. .:. :::: ':;iso:�;::::�:<?? 3�%:£:;:Y%xi::�?:;,.: ..:: ::: :::: :::: .::.: :..:::.. :. ::. .::.. ::... :::. .. _:::. :. TIN : ROU G OF SERVICES HR CST OUGH THESE SHADED AREA . SPECIFIED. I IN - SEC IED.REUSE EXISTING SWITCHING AND REPLACE EXISTING LIGHT FIXTURES WITH NEW LED FIXTURES AS G S :.. w • � WIRING ADJUST LOCATIONS AS PER REFLECTED CEILING PLAN ROOM OR SPACE NAME ISTIN�. � � ' ` XX °::.. '•. ;:.;:> .EI1N6. 131_II3I4TINGT MAIN _ ;:. .:,. ::> <: �:: :.: 2 ROOM OR SPACE NUMBER 3 .. ::. .... .. ISE:«.. ..: .:..:.::::.:..::.:::......:..:..:. R ,«<,.: " ' ::.:...,. ,..:...:.:.:...: O WCtR NLESS flTl�l< :. >:. ITS ENTIRETY AND REPLACED AT SAME <:::: :: :::;«::::::> .:.: :::. . ... ::..::::..:.::..:.::.::.:.:..::.:.::.::.:.::::. >.; ;:.: :,.;:.:;::::.:;;:: ::;:: ::;: >:: .... CEILINGHEIGHT HEIGHT WITH NEW SUSPENDED ACOUSTICAL TILES AND GRID AS SPECIFIED. 4. :: .. E.. IAI .. E E E FILING MATERIAL: CLIENT. ' •rr rrr r -fir rir aE rr :. EXISTING GYP.BOARD CEILING AND LIGHTING TO REMAIN UNLESS OTHERWISE NOTED OR INSTRUCTED BY OWNER i ................ X'-X" B D ACOUSTICAL CEILING TILE ACT=BLDG.STD. EXIST. . EX ST. ;.: ::.,. ;. >": ACT-1 EX T. ;;>...>;:.;<:...<;.;,..,;<.:....:::.:.::.:::..:::::::::::..:.::...:.. ..... .... ..... .:.:. :.... ......:.:::.::.:::::..::... ......:..:. .... .... EXISTING HVAC REGISTERS AND RETURNS TO BE CAREFULLY REMOVED AND REINSTALLED IN AME LOCATIONS IN � E E ' ACT-1 AC -1 S S S GYP-e THK.GYPSUM BOARD CEILING ACT-1 NEW CEILING GRID AND TILES. NO-NO CEILING EXISTING LAB T BE PATCHED PAINTED S 0 CH & -3 1/2' ::` '. ` :. CEILING GRID HEIGHT OR MATERIAL BREAK.GC SHALL PROVIDE GYPSUM BOARD L2 6 EXISTING LI AI E ST G SKY GHTS TO REMAIN. TO COORDINATE ANY WATER DAMAGE REPAIR WITH OWNER ACT :.. .: :::.. .:<:. ::.>: .:.:: .::.:.. >:.:::.::.;: :.::.. ::;:: ::::: ::>: >:: ::: :»::>>:.:,:>:;:; <::_:::»:>:::: ::.::.:;;;:;__;:::::::: :::>:;:;::::° _.:: :.; :: ;:.:� : HEADER AND FASCIA L2 ::>;::.: ;::..;:...:::.: .:.:. ::._. :::.. .:..:::.F:. ::::. ::.. ..:...:.:.. :. ..... :.. :::. .... SC BETWEEN CEILING HEIGHTS. . 4 :. RECESSED WALL MOUNTED LIGHT SWITCH.8"FROM DOOR TO CENTERLINE OF FIRST 4 ROCKER SWITCH .LIGHT SWITCH SHALL BE'LUTRON,MAESTRO SERIES,COLOR WHITE, E E TBD CONSULTANT: XIST. °' UNLESS OTHERWISE NOTED. NOTE. ALL LIGHT SWITCHES IN PRIVATE OFFICES SHALL 3 6 5 6 6 ;::;:..;.::.:... :;:.;.::::::: ® O O _ O O O :. EQ. E . NE � L2 L2 4 , ,; ,... . . _ ., .. BE WALL MOUNTED OCCUPANCY SENSOR TYPE, REFER TO ENGINEERING DRAWINGS L2 h- FOR ADDITIONAL INFORMATION AND SPECIFICATIONS. -STANDARD. SWITCH S S D RD LI HT - G C L1 3 1/2 E IST. RECEPTION TBD PER PROJECT D-DIMMING SWITCH ACT-1 A T-1 EXIST. ROCA TILE#F236160011 24W4' R OS OCCUPANCY SENSOR 2 A _ STRATOS ARTIC BLANCO OR-OVERRIDE SWITCHO E � 5 3 E COLOR.WHITE GLASSOS E 1 2' HAp O":. :.A ,DENOTE E SI.:.<IN . ... .........:.. :. ..: " F, R DENOTES LIGHT FIXTURE TO HAVE EMERGENCY BATTERY BACK UP POWER TO 3I ACT-1 H3:3 CEILINQANOLIGHTING"t't1Rf=MAtN f E�� � EM- ATOLO3 � L�'C1UP COMPLY W/LOCAL CODES. THIS LIGHT FIXTURE SHALL BE ON A SWITCHED CIRCUIT. 1f 1+U# RK.UNLESS..t CWI=ft15E':;. � L1 XHAU 1 5 SDG BRANDING-TBD 2 CFM XIST. LU ENT :_ ®E F EX ST. ;: 4 G 4 � .:..::::.::.::::::::::..:..:..... .... . .:..... ..,........ .. . . .. :.. ,.... ..:. .............................. ......... .. . .... ....... .:... NEW 2 X 2 A :;:.:>:;:.:::::>:.;::;>..::::: ::::...:::: :: ... ._: ..:::.:;::::....:..:: .;:. eo COUSTICAL CEILING GRID AND TILE.(ACT 1)• � _::::. .::::.,.:::...::::. ::....... ::. :.::. :.. .... ,. ,....,;;;.;>;" ARMSTRONG HEALTH ZONE OPTIMA#3216 9/16 SQUARE TEGULAR W/9/16 0� EXIST. Q u aUu fir= SILHOUETTE XL 1/8 REVEAL GRIDS ACT-1 L2 ':....: r , z r a L1 L1 "'EXISTING...;' w y: Z � 2 3 Tfl REMAIN,., , '.:. ,::. v> �� .. •�i� <:. 5 . .... ... ... ... .. .......... n n REFER TO A-100 FOR NEW CONSTRUCTION IN THIS AREA 4 TYPICAL BRANDING/SIGNAGE WAITING AREA WALL SCALE: 3/8"= 1'-0.. ::.:..... ... ..::.:.:::::. .... :::...::.. LIGHT FIXTURE SCHEDULE LAMPS 0. MAIN ROAD TYPE SYMBOL DESCRIPTION I MANUFACTURER CAT.N0. REMARKS VOLTS 0 S PE # TY .... .... ..:... ..... ... .:.. .... :. .... .... ..:.. .: ::.... I�. 2X4 RECESSED LED LIGHT FIXTURES TDJALED-2X4-LTGX-3500K- PROVIDE EMERGENCY PACK WHERE DENOTED BY L1 CORONET,TDJA LED SERIES VOLTAGE,VIF-T/SG-DB-VRB VIF - HALF SHADED FIXTURE WITH AN'E' :� ... �.. t 2X2 RECESSED LED LIGHT FIXTURES TDJALED-2X2-LTGX-3500K- PROVIDE EMERGENCY PACK WHERE DENOTED BY � t OVERALL REFLECTED CEILING PLAN � B CORONET,TDJA LED SERIES VOLTAGE,VIF-TISG-DB-VRB VIF - HALF SHADED FIXTURE WITHAN'E' 1 SCALE: 1/4"= 1'-0" -� SHADED AREA DESIGNATES ILLUMINATED FACE(S). mrww RECESSED EDGE LIT LED EXIT SIGN ESH7-2 ARROW(S)INDICATE DIRECTION TO EXIT-REFER TO EATON,SURE LITES ES SERIES EST7-2-WH-R-C PLAN. FINISH PLAN KEYNOTES STANDARD FINISHESSYMBOL DESCRIPTION ........................................................ ... .... ....... B1 WALL BASE-TBD-SIMILAR TO JOHNSONITE VINYL MILLWORK BASES .�»»» . : EGL SELECT WATERBORNE INTERIOR PAINT EGGSHELL _.. _ _. ... _. ..::_. . , ... _ .. ..,. REMOVE EXISTING CARPETING/PADDING PADDIN AND FLOORING : / N DOWN T BFL R. P. » COLOR:WHITE CN _ ::..:. >.. F1 - :. ... .. .. :.. .. >.. - 0 S G C G G 00 G 0 0 SU 00 TY LO P2-B.MOORE WATERBORNE SATIN IMP RV IN - T COLOR:WHITE S E 0 PAINT SATIN CO 0 TE 0 ' - •€7- ------cicff - F� ------ REF &O--- �- :.. - --- LPF1-MIDWOOD FLOORS MGL8002 3.5"Lx48"L COLOR:CANYON OAK O O 2 PL1- AFI A F PATCH ANY CRACKS R HOLES IN BARD WA T S CRY TALITE 474 R C C CSO O S GYP 0 LLS AND PREP FOR NEW AI - S L BRUSHED ALUMINUM DE DECORATIVE PANEL i O 0 P NT.TYP. CO S a " PL-1 PL-1 PL-1 TL1 GLAZZIO TILE#C11 4"x12 COLOR:MORNING MIST Z SS 1 TL-1 SS-1 TL-1 0 SS 1 TL-1 SS1 CAESARSTONE STYLE:2141 COLOR:BLIZZARD F4 ,. EXIST. F 4 O I „ Z Y S O I HARDWARE-EMTEK S62003SS 5.5 STAINLESS STEEL BAR PULL 3.5 CtC — U F3 CORRIDOREXISTING COUNTER TOP TO BE CAREFULLY REMOVED IN I 0 ITS ENTIRETY AND WALL P PAINT.PREPPED FOR NEW P a O .. EXIST. EXIST. EXIST L - ,: EXIST. XAM RM STAFF EXAM R P M RM EXI TIN F RNIT RE AND MILLWORK T BE REM VED AN o S G U U 0 0 D RET RNED T WNE N 1 I F4 U 0 0 R.AREA PREPPED FOR EW CL. O 2 RM #1 O :::- >:: MILLW RK K AT H EXI TIN INA , a 0 DES TOM C S G COORD TE RE IREMENT WIT �- I— t QU S H OWNER "IST. - HARD SURFACES w � ;":: w � o OFFICE AND RECEPTION F5 NEW BRANDING WALL TO MATCH STANDARD.REFER TO TYPICAL BRANDING ELEVATION. IL LPF LPF LPF F1 LPF P LPF P P P F2 1 1 1 P 1 1 1 1 1 1 1 1 1 1 p FS EXISTING SLIDING GLASS WINDOWS AND TRACKS TO BE REMOVED AND OPENINGS PATCHED AND REPAIRED TO FINISH WALL CEILING SOLID FLOOR FINISH NEW 2 2 r 2 MATCH ADJACENT SURFACES MATERIAL FINISH FINISH SURFACE CORRIDOR LPF P I 1 P P P F 1 EXISTING MILLWORK AND INK BE S G 0 S TO REMOVED AND REPLACED WITH NEW T 2 C T E STANDARD MILLWORK PACKAGE.REFER O 2 F e - e F3 EXIST. O O TO TYPICAL ELEVATION AND FINISH NOTES. ... ....... EA e 0 _ _ PRIVATE ep I I I I I I I I TOILET RM LPF P I I I I EXIST. I I I I I I I I F1 1 LPF P o FS EXISTING DOCTOR'S OFFICE FINISHES AND FURNITURE TO BE COORDINATED WITH OWNER. PAINT e 10) 1 1 1 I I I I Fj CORRIDOR I I I I I I F A ' � __ I I - -� I I � __ we I NEW ,_,.. ....,„... ......, ,; ..�, ,,.,.., ..�,. � - EXISTING FILING CABINET TO BE REMOVED AND RETURNED TO OWNER.EXISTING COUNTER TO BE SUPPORTED BY WALLCOVERING I EXAM RM I ,.. :.. P ........................ P P E BRACKETS AS REQUIRED. �..._ NEW CK x I #5 � - - - �I NEW 2 e 1 e ® c I L I I MOH'S e e � o CARPET _ I 1 1 I IST. _ O .:...:. :.. LAB �- - - EXIST. CL I EXIST. P `� __....__....i____......_.... PL-1 TE i EXAM RM F1 `� ; LPF P - I VINYL COMPOSITION TILE vcT 01 10.07.2016 ISSUED FOR FILING I I I 1 1 1 e REV DATE DESCRIPTION I I - - I I SS-1 TL-1 I OFFI E I #3 � � :; .�.._._. I ' DML�l1 IS F5 EXIST. I I SS-1 TL-1 - - I I F8 ®7 LPF P � I i ; I ® O �:.: : . :. I 1 i ` F2 F1 WAITING ROOM ! i WALL BASE B" ��vi ®netic5® O• I >` T i....................1....._..__....-. --1-- EXIS I FPL-1 si I E vIro a ihatWc� , A/R Environetics Architects, P.C. I '�--�---'--"- IVA O SS-1 TL-1 \ � � I PLASTIC LAMINATE PL- 1 LPF P T ET RM o\ I 0 116 East 27th Street 1212679 8100 1 'O New York,NY 10016 f 212 685 9044 P I I 0 C ri ht® b Environetics.All Rights Reserved. P 9 1 v r 9 O I A T LAVE-TBD U OC >: ::: .::: OLID SURFACE PROJECT NO E2623 I .,. ALE ::.J. :. : ..,. A NOTED LAB ........................I...................... I SAFETY STORAGE CABINET AVANTIK SY5032-B DRAWN BY: KB LABVAC AVANTIK LV12-K CHECKED BY: KB j I DRAWING TITLE: I ----_-"---'i"--"- -� GROUND FLOOR EXIST. ____1_ LINISTAINAUTOMATICSLIDESTAINER-AVANTIKEQ0534 OVERALL REFLECTED CEILING FOYER III I W/FUME CONTAINMENT HOOD ABOVE-AVANTIKSY5014-A PLAN, OVERALL FINISH PLAN, I --""-'.^;.""""'.•""'•"' SCHEDULES, NOTES AND MAINROAD ' DETAILS CRYOSTAT-AVANTIK QS12 DRAWING NUMBER: GREENO WC-4-TCSCH-L WASTE CHUTE/SHARPS CONTAINER /-\' 101 .00 ELKAY ELUH1212 LAV W/KOHLER K-7509-CP FAUCET SHEET SET NUMBER 03 OF 3 SHEETS SOAP DISPENSER,LUCITE C-FOLD TOWEL HOLDER-TBD 2 OVERALL FINISH PLAN 3 ENLARGED MOH'S LAB EQUIPMENT PLAN SCALE: 1/4"= 1'-0" SCALE: 1/2"= 1'-0"