HomeMy WebLinkAbout41348-Z REVISIONS:
A
-----------------
-----------------------
32'-8" EXISTING POOL
10
4'-01/4" 5-81/2" 4'-01/4 9'-9" 10'-71/2" 12'-31/2"
TW24410-2
(2)2X10 HDR
o ��� °� \ J`'+,o �R'°a 0j NEW PATIO
-4- STONE
00
2 of EXISTING LOWER DECK
Lu
o
rn
' W z
d N FAMILY ROOM EXPANDED C13 P4030 C13 FWG60681Z P3060 P3060
O o CATHEDRAL CEILING __
o i (2)2Xil DER (2)2X10 DF#2 HEADER (2)2X10 (2)2X10
x I O 1 HDR 1 HDR C)
' IIT3Z
1 1 I 1 1 1 =T3 ~
I I
'NEW, ' NEW, 'NEW ' x O
16X45; ;16X45; 6X45, CATHEDRAL
----�
SKYLIGHT SKYLIGHT SKYLIGHT CEILING
1 I 1 1 1 1 O
00
KITCHEN o N o EXISTING UPPER DECK Q
IA x M
5'-0"
7X3X1/8 (4)1-3/4X9-1/4 ML' �® 4 mi9-1/41-3/4X9-1/4 ML W/(3)3/4"STEEL FLUSH BEAM •-T 7X3X1/8
O I STEEL ST El. S. STEEL
------------ I COLUMN COL N x ID COLUMN
EXISTING BATH I 6,-33/8„(VIF) 16'-81/8”(VIF) ^' o
--------- No. I o
r
EXISTING FMILY ROOM
EX.CATHEDRAL CEILING
o W
DINING
rl
EXISTING I I I r l ''--'1 O �D
MUD ROOM I I I r r a
----------- rl O H
----------- - - - - - ,�
ADJUST ROUND TOP WINDOW
HEIGHT AS NEEDED TO NOT
IZZW
INTERFERE WITH PERGOLA
1 ------------
I
I
------------------- W.I.C. '----"-' EX. LIVING ROOM o
t I -------- ('7
GN M V
1
--------------
----------- -� L� +�
1 ----- --------- X ^" V
' O M t� t✓i .4+
EXISTING MASTER BEDROOM O
--------- x o
1 O / \ Ln Cu,
y �,
N EXISTING GARAGE EX. ENTRY P4
' S/8"TYPE-X FIRE RATED SHEETROCK ON •--- - = r. u m +'
Z , , __"-; (2)2X10 DF#2 GIRDER ,,
1 WALLS AND CEILING(REPLACE AS REQ.) 1 NEW 1 - - - - - ,�'
1 30X30 ' m
Lu 'SISTER C7Xl4_7 STFFL TO EACH EX.;)X8 JOIST 0.16"QC
di
+ ; SKYLIGHT ; ' N j
z1 ALT.TJ1560 14"@16-OC EX. MASTER BATH r :____ Ill
1 I w � /2X6 Cl 0,16110C
Lu '
] 1 ♦ w
1
l EX,2X8 FJ ` 0 r7
♦ 7
1
1 � � ♦GO 0 �
`tCCPORCH ��
1 I BARREL I �♦ N 1 V
------------------- i� i
CEILING STONE M 0
10X10 FG COLUMN I `♦ v I
6X6 ACQ POST(7YP.)
3 2X10 DF#2 GIRDER •--1 3 2X10 DF#2 GIRDER 1
•-- ( ) ( ) -- (--• — - —(3)2X10 DF#2 GIRDER (3)2X10 DF#2 GIRDER -• c
�� d1).USE 3/4"T&G ADVANTECH ENGINEERED SUBFLOORING,INSTALLED WITH 8).INSTALL FIRE BLOCKING,FIRE COLLARS,CAULKING,etc IN CEILINGS
RING SHANK OR SCREW SHANK NAILS AND SUBFLOOR ADHESIVE PER (MAX.10'OC)AND INTERSECTING WALLS,LOAD-BEARING WALLS, APR 1 0 2,917
MANUFACTURE'S INSTRUCTIONS. FRAMED CHIMNEY/DUCT CHASES,VENTS,PIPE PENETRATIONS,etc. 9 PER CODE. -0ll 12 -31h 12'-31/2"
10 -11 10 -11
3). PLATE HEIGHT TO MATCH EXISTING 8'-0"+/-UNLESS OTHERWISE NOTED. ]0UMI3Ii+(a Dj,
9).ALL EXTERIOR OPENINGS TO HAVE DESIGN-PRESSURE UPGRADES WHERE A �-+
4). EXTERIOR WALLS TO BE FRAMED WITH 2X4 DF#2 STUDS AT 16"O.C.. APPLICABLE.PROVIDE DEBRI-PROTECTION PANELS WITH FASTENING TO��1"�® SOUTITOLD
HARDWARE UNLESS OPENINGS HAVE IMPACT GLAZING.
5).EXTERIOR SHEATHING TO BE 1/2"THICK FIR CDX PLYWOOD.
10).INSULATE ALL NEW EXTERIOR WALLS.SEE ENERGY COMPLIANCE REPORT. WALL LEGEND
6).DOUBLE UP FLOOR JOISTS UNDER PARALLEL WALLS ABOVE AND UNDER yr-r
ALL BATHS.PROVIDE BLOCKING AT 8'-0"O.C.AND MIDSPAN. 11).ALL WALLS AND CEILINGS TO BE PROVIDED WITH 1/2"SHEETROCK. --------------
`-------------- ` a♦
, WALL TO BE REMOVED �G�•f�+
7).PROVIDE 3-2X10 DF#2 HEADERS OVER ALL OPENINGS UNLESS 12).ALL FLOOR TILE AREAS TO HAVE MUD SETTING.
OTHERWISE NOTED.ALL OPENINGS OVER 3 FT.TO HAVE 2 JACK STUDS EXISTING WALL '�• ry✓
ON EACH SIDE OF OPENING.PROVIDE 3 JACK STUDS ON EACH SIDE FOR 13).INSTALL SMOKE AND CO DETECTORS AS REQUIRED BY CODE.
MICROLAM HEADERS. NEW WALL S
,t1i
E W PROJECT NORTH 1ST. FLOOR PLAN , * zrt} fi t. DRAWN: MH MS
NOTE: SCALE: 1/4"=1'-0"
DIMENSIONS OF EXISTING WALLS ARE FROM FINISHED WALLn �' JOB#:
INT.:2X4=4-i 2" 2X6= 6-1 2" EXT.:2X4=4-" 2X6 =6" N SCALE. 1/4 = 1
[ / / ] .N, �j'"r November 07,2016
t' Nom"
DIMENSIONS OF NEW WALLS ARE FROM STUDS SHEET NUMBER:'Y
[EXT./INT.:2X4= 3-1/2",2X6= 5-1/2"]
REVISIONS:
---------------
I I
I �
A
I �
-------------------------------------------------------------------------------------------------
I �
I I
I �
I '
1 '
I '
I '
1 '
I �
I
I
I
I
I
I
I
' OI
' HI
1 I
I
I
,
I
I a
5 —21/2" F--�
' � O
1
CIR24 i C
—
----------------------------
TEMPERED ' z
\ / (2)2X8 HDR
I N
I O
I n�+
I LL
/ 6'-8" 11'-91/2" 11'-10" `
I 111
EX. BEDROOM �'
O EX. BEDROOM
CC
^ Cl „
LL
r SLOPED N EW — — — -- — —
r ul
I
, n1
------- CEILING -------------- F BATH I I
I , 1
O I I III
v,
Itl T,
2'-6rr
III O f7-+
1 1 1 I I I11 u ��II
Lu
I
1 I I 1 , 111 O
N W , , , , III •��
W M
OM LL = ---- -- - - - — - — - — - — - -
O
cXvLL Lu v SOLID-CORE DOOR = ———— ———— ` — „1
O H
CC o w/WEATHER -------------------- >
AND DOOR SWEEP
N ' n1
i n1
ATTIC / STORAGE
III
UNHEATED(ALTERED) OPEN `-``-`"
TO
BELOW _- ---_-- '
, nI
------------------------/7__ — — — — — — ------------------------ — —— — — —
(3)2X8 DF#2
SLOPED , , , , SLOPED NEW BEDROOM
CEFC, / ' \ CEI],ING ,
CV7 1 1 CV7 I
CN NEW i r __ ----------------
30X30
_____________ _30X30 1 III
' 1 SKYLIGHT
1 ( 1 X ^ u
1 1 (2)2X8 HDR (2)2X8 HDR ' iii C .2
016"0C ---------------------------- --------------------------------------------- c-i
1 T-0"CEILING HEIGHT i \ TW3n1 X O
Gi421
c. JI 46
Lu 1 �\ (EGRESS) (46 EGRO S) iii O =4
OW l l Q ti! III G1 +'
V1 U1 1tn U III � � �
1:15 u
ROOF POCKETS(TYP.) 111
111 m a
A PITCH MIN.1/4:12 FROM Ln U ^+ v
HOUSE,LEAD COATED iii � Ui
COPPER OVER EPDM, N y
3/4"EXT.GRADE SHTG. n1 0 W
I I
I 1
i (2)2X8 HDR. --------------------------------------------------------------- ---------------- ii1 R-1
---------------------------------------------------------------
TW3046-2
12'-0" 12'-0" 9'-71/2" e 8'-2" f 3'-6" 01
w
24'-0" 21'-31h" V
O
1).USE 3/4"T&G ADVANTECH ENGINEERED SUBFLOORING,INSTALLED WITH 8).ALL EXTERIOR OPENINGS TO HAVE DESIGN-PRESSURE UPGRADES WHERE WALL LEGEND
RING SHANK OR SCREW SHANK NAILS AND SUBFLOOR ADHESIVE PER APPLICABLE.PROVIDE DEBRI-PROTECTION PANELS WITH FASTENING Q'
MANUFACTURE'S INSTRUCTIONS. HARDWARE UNLESS OPENINGS HAVE IMPACT GLAZING. --------------
WALL TO BE REMOVED
------------- N
2).ATTIC SHEATHING TO BE 3/4 APA RATED PLYWOOD. 9).INSULATE ALL EXTERIOR AND INTERIOR WALLS.SEE ENERGY
COMPLIANCE REPORT. EXISTING WALL S
3).MATCH EXISTING WALL PLATE HEIGHT(VIF), P ROJ ECT NORTH 2ND. FLOOR PIAN_
10).ALL WALLS AND CEILINGS TO BE PROVIDED WITH 1/2"SHEETROCK.
4).EXTERIOR WALLS TO BE FRAMED WITH 2X4 DF#2 STUDS AT 16"O.C.. BATHROOMS TO BE INSTALLED WITH MOISTURE-RESISTANT NEW WALL E
SHEETROCK.USE DUROCK CEMENT BOARD AT SHOWER/BATH TILE
5).EXTERIOR SHEATHING TO BE 1/2"THICK FIR CDX PLYWOOD. AREAS. NOTE: N SCALE. 1/4" = 1'
DIMENSIONS OF EXISTING WALLS ARE FROM FINISHED WALL x
6).PROVIDE 3-2X8 DF#2 HEADERS OVER ALL OPENINGS UNLESS 11).ALL FLOOR TILE AREAS TO HAVE MUD SETTING. [INT.:2X4=4-1/2",2X6 =6-1/2",EXT.:2X4=4- 2X6=6")
OTHERWISE NOTED.ALL OPENINGS OVER 3 FT.TO HAVE 2 JACK STUDS
ON EACH SIDE OF OPENING.PROVIDE 3 JACK STUDS ON EACH SIDE FOR 12).INSTALL SMOKE AND CO DETECTORS AS REQUIRED BY CODE. DIMENSIONS OF NEW WALLS ARE FROM STUDS
MICROLAM HEADERS. (EXT./INT.:2X4= 3-1/2",2X6 = 5-1/2"
7). INSTALL FIRE BLOCKING,FIRE COLLARS,CAULKING,etc IN CEILINGS , 4
(MAX.10'OC)AND INTERSECTING WALLS,LOAD-BEARING WALLS,
FRAMED CHIMNEY/DUCT CHASES,VENTS,PIPE PENETRATIONS,etc.
PER CODE.
DRAWN: MH/MS
" SCALE: 1/4"=1'-0"
JOB#:
November 07,2016
SHEET NUMBER:
4 �P 9kDEE09- Hfl�a��d® -7