Loading...
HomeMy WebLinkAbout41348-Z REVISIONS: A ----------------- ----------------------- 32'-8" EXISTING POOL 10 4'-01/4" 5-81/2" 4'-01/4 9'-9" 10'-71/2" 12'-31/2" TW24410-2 (2)2X10 HDR o ��� °� \ J`'+,o �R'°a 0j NEW PATIO -4- STONE 00 2 of EXISTING LOWER DECK Lu o rn ' W z d N FAMILY ROOM EXPANDED C13 P4030 C13 FWG60681Z P3060 P3060 O o CATHEDRAL CEILING __ o i (2)2Xil DER (2)2X10 DF#2 HEADER (2)2X10 (2)2X10 x I O 1 HDR 1 HDR C) ' IIT3Z 1 1 I 1 1 1 =T3 ~ I I 'NEW, ' NEW, 'NEW ' x O 16X45; ;16X45; 6X45, CATHEDRAL ----� SKYLIGHT SKYLIGHT SKYLIGHT CEILING 1 I 1 1 1 1 O 00 KITCHEN o N o EXISTING UPPER DECK Q IA x M 5'-0" 7X3X1/8 (4)1-3/4X9-1/4 ML' �® 4 mi9-1/41-3/4X9-1/4 ML W/(3)3/4"STEEL FLUSH BEAM •-T 7X3X1/8 O I STEEL ST El. S. STEEL ------------ I COLUMN COL N x ID COLUMN EXISTING BATH I 6,-33/8„(VIF) 16'-81/8”(VIF) ^' o --------- No. I o r EXISTING FMILY ROOM EX.CATHEDRAL CEILING o W DINING rl EXISTING I I I r l ''--'1 O �D MUD ROOM I I I r r a ----------- rl O H ----------- - - - - - ,� ADJUST ROUND TOP WINDOW HEIGHT AS NEEDED TO NOT IZZW INTERFERE WITH PERGOLA 1 ------------ I I ------------------- W.I.C. '----"-' EX. LIVING ROOM o t I -------- ('7 GN M V 1 -------------- ----------- -� L� +� 1 ----- --------- X ^" V ' O M t� t✓i .4+ EXISTING MASTER BEDROOM O --------- x o 1 O / \ Ln Cu, y �, N EXISTING GARAGE EX. ENTRY P4 ' S/8"TYPE-X FIRE RATED SHEETROCK ON •--- - = r. u m +' Z , , __"-; (2)2X10 DF#2 GIRDER ,, 1 WALLS AND CEILING(REPLACE AS REQ.) 1 NEW 1 - - - - - ,�' 1 30X30 ' m Lu 'SISTER C7Xl4_7 STFFL TO EACH EX.;)X8 JOIST 0.16"QC di + ; SKYLIGHT ; ' N j z1 ALT.TJ1560 14"@16-OC EX. MASTER BATH r :____ Ill 1 I w � /2X6 Cl 0,16110C Lu ' ] 1 ♦ w 1 l EX,2X8 FJ ` 0 r7 ♦ 7 1 1 � � ♦GO 0 � `tCCPORCH �� 1 I BARREL I �♦ N 1 V ------------------- i� i CEILING STONE M 0 10X10 FG COLUMN I `♦ v I 6X6 ACQ POST(7YP.) 3 2X10 DF#2 GIRDER •--1 3 2X10 DF#2 GIRDER 1 •-- ( ) ( ) -- (--• — - —(3)2X10 DF#2 GIRDER (3)2X10 DF#2 GIRDER -• c �� d1).USE 3/4"T&G ADVANTECH ENGINEERED SUBFLOORING,INSTALLED WITH 8).INSTALL FIRE BLOCKING,FIRE COLLARS,CAULKING,etc IN CEILINGS RING SHANK OR SCREW SHANK NAILS AND SUBFLOOR ADHESIVE PER (MAX.10'OC)AND INTERSECTING WALLS,LOAD-BEARING WALLS, APR 1 0 2,917 MANUFACTURE'S INSTRUCTIONS. FRAMED CHIMNEY/DUCT CHASES,VENTS,PIPE PENETRATIONS,etc. 9 PER CODE. -0ll 12 -31h 12'-31/2" 10 -11 10 -11 3). PLATE HEIGHT TO MATCH EXISTING 8'-0"+/-UNLESS OTHERWISE NOTED. ]0UMI3Ii+(a Dj, 9).ALL EXTERIOR OPENINGS TO HAVE DESIGN-PRESSURE UPGRADES WHERE A �-+ 4). EXTERIOR WALLS TO BE FRAMED WITH 2X4 DF#2 STUDS AT 16"O.C.. APPLICABLE.PROVIDE DEBRI-PROTECTION PANELS WITH FASTENING TO��1"�® SOUTITOLD HARDWARE UNLESS OPENINGS HAVE IMPACT GLAZING. 5).EXTERIOR SHEATHING TO BE 1/2"THICK FIR CDX PLYWOOD. 10).INSULATE ALL NEW EXTERIOR WALLS.SEE ENERGY COMPLIANCE REPORT. WALL LEGEND 6).DOUBLE UP FLOOR JOISTS UNDER PARALLEL WALLS ABOVE AND UNDER yr-r ALL BATHS.PROVIDE BLOCKING AT 8'-0"O.C.AND MIDSPAN. 11).ALL WALLS AND CEILINGS TO BE PROVIDED WITH 1/2"SHEETROCK. -------------- `-------------- ` a♦ , WALL TO BE REMOVED �G�•f�+ 7).PROVIDE 3-2X10 DF#2 HEADERS OVER ALL OPENINGS UNLESS 12).ALL FLOOR TILE AREAS TO HAVE MUD SETTING. OTHERWISE NOTED.ALL OPENINGS OVER 3 FT.TO HAVE 2 JACK STUDS EXISTING WALL '�• ry✓ ON EACH SIDE OF OPENING.PROVIDE 3 JACK STUDS ON EACH SIDE FOR 13).INSTALL SMOKE AND CO DETECTORS AS REQUIRED BY CODE. MICROLAM HEADERS. NEW WALL S ,t1i E W PROJECT NORTH 1ST. FLOOR PLAN , * zrt} fi t. DRAWN: MH MS NOTE: SCALE: 1/4"=1'-0" DIMENSIONS OF EXISTING WALLS ARE FROM FINISHED WALLn �' JOB#: INT.:2X4=4-i 2" 2X6= 6-1 2" EXT.:2X4=4-" 2X6 =6" N SCALE. 1/4 = 1 [ / / ] .N, �j'"r November 07,2016 t' Nom" DIMENSIONS OF NEW WALLS ARE FROM STUDS SHEET NUMBER:'Y [EXT./INT.:2X4= 3-1/2",2X6= 5-1/2"] REVISIONS: --------------- I I I � A I � ------------------------------------------------------------------------------------------------- I � I I I � I ' 1 ' I ' I ' 1 ' I � I I I I I I I ' OI ' HI 1 I I I , I I a 5 —21/2" F--� ' � O 1 CIR24 i C — ---------------------------- TEMPERED ' z \ / (2)2X8 HDR I N I O I n�+ I LL / 6'-8" 11'-91/2" 11'-10" ` I 111 EX. BEDROOM �' O EX. BEDROOM CC ^ Cl „ LL r SLOPED N EW — — — -- — — r ul I , n1 ------- CEILING -------------- F BATH I I I , 1 O I I III v, Itl T, 2'-6rr III O f7-+ 1 1 1 I I I11 u ��II Lu I 1 I I 1 , 111 O N W , , , , III •�� W M OM LL = ---- -- - - - — - — - — - — - - O cXvLL Lu v SOLID-CORE DOOR = ———— ———— ` — „1 O H CC o w/WEATHER -------------------- > AND DOOR SWEEP N ' n1 i n1 ATTIC / STORAGE III UNHEATED(ALTERED) OPEN `-``-`" TO BELOW _- ---_-- ' , nI ------------------------/7__ — — — — — — ------------------------ — —— — — — (3)2X8 DF#2 SLOPED , , , , SLOPED NEW BEDROOM CEFC, / ' \ CEI],ING , CV7 1 1 CV7 I CN NEW i r __ ---------------- 30X30 _____________ _30X30 1 III ' 1 SKYLIGHT 1 ( 1 X ^ u 1 1 (2)2X8 HDR (2)2X8 HDR ' iii C .2 016"0C ---------------------------- --------------------------------------------- c-i 1 T-0"CEILING HEIGHT i \ TW3n1 X O Gi421 c. JI 46 Lu 1 �\ (EGRESS) (46 EGRO S) iii O =4 OW l l Q ti! III G1 +' V1 U1 1tn U III � � � 1:15 u ROOF POCKETS(TYP.) 111 111 m a A PITCH MIN.1/4:12 FROM Ln U ^+ v HOUSE,LEAD COATED iii � Ui COPPER OVER EPDM, N y 3/4"EXT.GRADE SHTG. n1 0 W I I I 1 i (2)2X8 HDR. --------------------------------------------------------------- ---------------- ii1 R-1 --------------------------------------------------------------- TW3046-2 12'-0" 12'-0" 9'-71/2" e 8'-2" f 3'-6" 01 w 24'-0" 21'-31h" V O 1).USE 3/4"T&G ADVANTECH ENGINEERED SUBFLOORING,INSTALLED WITH 8).ALL EXTERIOR OPENINGS TO HAVE DESIGN-PRESSURE UPGRADES WHERE WALL LEGEND RING SHANK OR SCREW SHANK NAILS AND SUBFLOOR ADHESIVE PER APPLICABLE.PROVIDE DEBRI-PROTECTION PANELS WITH FASTENING Q' MANUFACTURE'S INSTRUCTIONS. HARDWARE UNLESS OPENINGS HAVE IMPACT GLAZING. -------------- WALL TO BE REMOVED ------------- N 2).ATTIC SHEATHING TO BE 3/4 APA RATED PLYWOOD. 9).INSULATE ALL EXTERIOR AND INTERIOR WALLS.SEE ENERGY COMPLIANCE REPORT. EXISTING WALL S 3).MATCH EXISTING WALL PLATE HEIGHT(VIF), P ROJ ECT NORTH 2ND. FLOOR PIAN_ 10).ALL WALLS AND CEILINGS TO BE PROVIDED WITH 1/2"SHEETROCK. 4).EXTERIOR WALLS TO BE FRAMED WITH 2X4 DF#2 STUDS AT 16"O.C.. BATHROOMS TO BE INSTALLED WITH MOISTURE-RESISTANT NEW WALL E SHEETROCK.USE DUROCK CEMENT BOARD AT SHOWER/BATH TILE 5).EXTERIOR SHEATHING TO BE 1/2"THICK FIR CDX PLYWOOD. AREAS. NOTE: N SCALE. 1/4" = 1' DIMENSIONS OF EXISTING WALLS ARE FROM FINISHED WALL x 6).PROVIDE 3-2X8 DF#2 HEADERS OVER ALL OPENINGS UNLESS 11).ALL FLOOR TILE AREAS TO HAVE MUD SETTING. [INT.:2X4=4-1/2",2X6 =6-1/2",EXT.:2X4=4- 2X6=6") OTHERWISE NOTED.ALL OPENINGS OVER 3 FT.TO HAVE 2 JACK STUDS ON EACH SIDE OF OPENING.PROVIDE 3 JACK STUDS ON EACH SIDE FOR 12).INSTALL SMOKE AND CO DETECTORS AS REQUIRED BY CODE. DIMENSIONS OF NEW WALLS ARE FROM STUDS MICROLAM HEADERS. (EXT./INT.:2X4= 3-1/2",2X6 = 5-1/2" 7). INSTALL FIRE BLOCKING,FIRE COLLARS,CAULKING,etc IN CEILINGS , 4 (MAX.10'OC)AND INTERSECTING WALLS,LOAD-BEARING WALLS, FRAMED CHIMNEY/DUCT CHASES,VENTS,PIPE PENETRATIONS,etc. PER CODE. DRAWN: MH/MS " SCALE: 1/4"=1'-0" JOB#: November 07,2016 SHEET NUMBER: 4 �P 9kDEE09- Hfl�a��d® -7