HomeMy WebLinkAbout41493-Z TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following,before applying?
TOWN HALL Board of Health
SOUTHOLD,NY 11971 Oets of Building Plans_
TEL: (631)765-1802 Planning Board approval
FAX: (631)765-9502 Qrvey .._.
SoutholdTown.NorthFork.net PERMIT NO. Check
--Septic Form
.S.D.E.C.
tees
Application
flood Permit
Examined 203ingle 8i Separate
Stean-Water Assessment Form
p Contact:
L.
Approved ' ."'. ,2017
Disapproved a(cI Phone:
____._.
Expiration '2
Bal ° n e .
PLICATION FOR BUILDING PERMIT
A 2 2Q17
Date 03/lY 12017
INSTRUCTIONS
TQV0i0*§QVWQRT be completely filled in by typewriterr or in ink and submitted to the Building Inspector with 4
sets of plans,accurate plot plan to scale.Fee according to schedule.
b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas,and waterways.
c.The N4ork covered by this application may not be commenced before issuance of Building Permit.
d.Upon approval of this application;the Building Inspector will issue a Building Permit to the applicant.Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the
property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an
addition six months.Thereafter,a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to.the
Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or
Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The
applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit
authorized inspectors on premises and in building for necessary inspections.
(Signature plicart or name,if a corporation)
(Mailing address of applicant)
State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder
CSC`
Name of owner of premises M-r6 ffoa 4 P-G,ub`r Vf-6.6_TAA)®
(As on the tax roll or latest deed)
If applicant is a corporation,signature of duly authorized officer
-------
(Name and title of corporate officer)
Builders License No,
Plumbers License No.
Electricians License No.
Other Trade'&License No.
k Location of land on which proposed work will be done:
70s- TGH6(-06
House Number Street Hamlet
County Tax Map No. 1000 Section '7 Block Lot /j
Subdivision Filed Map No. Lot
1 State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy F"',e-:5 b 771"4 e.,
b. Intended use and occupancy P-tfl�L 6,c m XT T-6 L-
3, Nature of work(check which applicable):New Building Addition Alteration
Repair Rem oval---.--....—Demolition Other Work
(Description)
4. Estimated Cost 01 00 Fee
(To be paid on,filing this application)
5. If dwelling,number of dwelling units_j�ZP_Number of dwelling units on each floor A,11,I
If garage, number of cars 1
,6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. A•llq
7. Dimensions of existing structures,if any:'Front_ RearDepth
Height Number of Stories
Dimensions of same structure with alterations or additions: Front Rear
Depth Height Number of Stories
8, Dimensions of entire new construction:Front —Rear -Depth
Height Number of Stories
9.', Size of lot:Front d Rear f t70 —Depth
10.Date of Purchase Name of Former Owner 7:f,3 6
I I.Zone or use district in which premises are situated
12,Does proposed construction violate any zoning law,ordinance or regulation?YES®
NO
13.Will lot be re-graded?YES®NO/Will excess fill be removed from premises?YES—NO V1'
14,NainesofOwtiero paremises Address Phone No.
Address Phone No
Name of Contractor X56 105c H w21sb t t N-1 Phone No. .31 - 731i
15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES—NO-
* IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED.
b.Is this property within 300 feet of a tidal wetland?*'YES—NO
IF YES,D.E.C.PERMITS MAY BE REQUIRED.
16.Provide survey,to scale,with accurate foundation plan and distances to property lines,
17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey.
1, .Are there any covenants and restrictions with respect to this property?*YES_NO
IF YES,PROVIDE A COPY.
STATE OF NEW YORK)
SS..
CO�JNIY 0 L�
A h`0 t 10 a U6 being duly sworn,deposes and says that(s)he is the applicant
.1, q
(Name dividual'ss',niq"intract)above named,
(S)He is the
(Contractor,Agent,Corporate Officer,etc.)
said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief,and thaglo,,g,n &Ql
4g,
performed in the manner set forth in the application filed therewith. Notary Public,State of New York
No.0 f G06351875
S worn to before me this Qualified in Suffolk County
20 Commission Expires Decembe,12,20
day of
l otary ub I Sig$Wre of Applicant
Scott A. Fussell � °� S�C'�CJ�]E�I��1 WA�'7C']EIK
SUPERVISOR 1\\4A\\.NA\\,G1E1\\41E'N1F
SOU OLD TOWN HALL-P.O.Box 1179 Town of Southold
53095 Main Road-SOU OLD,NEW YORK 11971
CHAPTER 236 STORMWATER MANAGEMENT WORK SHEET
( TO COMPLETED THE APPLICANT )
IG:It: II11'II a IIR.t::]UI f.T' INVOI.,VE ANY OF °111E Iat.:ll:.,LOWING:
dc'tBECK AII._, "t'BATl' APPLY)
Ycs No
00""A. Clearing, grubbing, grading or stripping of land which affects more
than 5,000 square feet of groundsurface.
Excavation or filling involving ore than 200 cubic yards of material
within any parcel or any contiguous area.
El C® Site preparation on slopes which exceedfeet vertical rise to
100 feet of horizontal distance.
Site preparation within 100 feet of wetlands, beach, bluff or coastal
erosion hazard area.
Site preparation within te one-hundred-year f loodplain as depicted
on FIRM Mapof any watercourse.
F. Installation of new or resurfaced impervious surfaces of 1,000 square
feet or more, unless prior approval of a Stormwater Management
Control Plan was received by the Town and the proposal includes
in-kind replacement of impervious surfaces.
If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your flame,
apply to your project.
f you tanswered YES act to one o® more of County above, please submit T o copieseof tdor water _ of Plan
Management Control Plan
and a completed Check List Form to the Building Department widi your Building Permit Application.
AVTI�B.. CA.b'yM. (Property Owner, ��sd�;uv�ircvP���°io V, �eiru4,L¢.uirPvir;.rcrV r,C?u:G er)NAME: V1;66:T1j#V0t '13-
Jr.�.T.M. #: �000 ��kc
v . .. _ section ff 'mc -Lot
,r
war
+ �J
levueinerlBy= ....._
Date:
(b1 0pefl ' Address L_ocPuollUof ConstiucUbon rUk: tr for poce:°uirgBuaoBa Penivc;t ��e.a.�aa�°E�
�'a
_ S'torpuveyater llMru'�Rag uubQ�rra
�o�uPrcra� cirreUuuV.
¢yurrir��uateA Ia��roua .. ._ � ... _.
pp gqtt�r:gqpy�� qqfl,,//ry' 'TOS
MAY
�/ 1 t (Fa��uwiird to�:ngi� ue:euusiHT De�Gart�nnic.irut lair Revuewr..)
Ir�..fVA�.�4A {1 C."N4(.:P_..'TO.J'S 1.0`ll p F...014
RE, III IIID I
��� ilii 4.6.4
Compliance Certificate
Project Viggiano Residence
Energy Code: 2015 IECC
Location: Southold, New York
Construction Type: Single-family
Project Type: Alteration
Climate Zone: 4 (5572 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
905 Harbor Lane ED NICHOLSON
Cutchogue, NY 11935 NORTH FORK KITCHENS&BATHS
1250 EVERGREEN DRIVE
CUTCHOGUE, NY 11935
631 734-8087
m
Ceiling 1: Flat Ceiling or Scissor Truss 391 49.0 0.0 0.026 10
Ceiling 2:Cathedral Ceiling ___, --- _._ -_-
Exemption: Framing cavity filled with insulation
Wall 2:Wood Frame, 16" o.c. 888 21.0 0.0 0.057 46
Door 3: Solid 40 0.270 11
Door 3 copy 1: Glass 48 0.350 17
SHGC:0.26
Floor 1:All-Wood joist/Truss, Over Unconditioned Space 391 21.0 0.0 0.044 17
Floor 2: All-Wood joist/Truss, Over Outside Air 365 21.0 0.0 0.044 16
Mecjhan
Other(Except Gas-Fired Steam) J 80 AFUE
" op
r
UJ
W
m
PE SSE; �
Project Title: Viggiano Residence Report date: 03/31/17
Data filename: C:\Users\ d\Documents\R Schec \example.rc � Page 1 of 10
Compliance.Statement. The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The O'rophed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.4 and to comply with the mandatory regal tints listed in the EEScheck Inspection Checklist.
M1 a me-Titlesiglh—
1
Gate
Project(Votes:
Project lee Viggiano Residence Report date:
3/31/17
Data file eo C:\Users\Ed\Doc u ments\RESchec \exa m pie.rc age 2 of10
REScheck Software Version 4.6.4,
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 100.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and hove that is documented, or that an exception
is being claimed', Where compliance is itemized in a separate table,„ a reference to that table is provided,
.....�..,, ._ Complies?s� C�
Re IIID .o.,.,.�, IR w iu�wttrieint.�/Assuuwr�Rt°iaam�s
103.1 Construction..,lie tion/Pian Review
mmIVue� me rmeiVerified
drawings and ,❑Complies Requirement will be met.
103.2 documentation demonstrate '❑Does Not
[PR111 energy code compliance for the
k' building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ❑Complies Requirement will be met.
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. ❑Not Observable
Systems serving multiple []Not Applicable
.dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302 1, Heating and coolingH ..n. : g_..0 �¢ Does Not � q
[ 3. mmmmmµ sized
per
ACC Manual S based Btu/hr g Btu/hr E]Dom lies Requirement will m _� ....
equipment is Heating: Heatm be met.
z d per ACCA
Manual J or other methods Cooling; Cooling: ❑Not Observable
approved by the code official. Btu/hr Btu/hr ❑Not Applicable
����,,,.w._ � .. .... _ ����v.. .m .. ... � .m. .......... �. .�._ .�... ....� .�._ J
Additional Comments/Assumptions:
�.High Impact(Tier 1) p �
�..
:� Low Impact(Tier 3) 1
1 2 Medium Impact(Tier 2���...........
Project Title: Viggiano Residence Report date: 03/31/17
Data filename: C:\Users\Ed\Documents\REScheck\example.rck Page 3 of10
�._ . �....� .................__
Setinn
AD Foundation Inspection n �o api'ies? con°nrnnenntsiAss u m�pt.ions.
ep
30 f 1 protect exposed exterior is ins ....,�,E n: Requirement
;i� M� � A protective covering installed to �Oompi�e Exception: Requirement is not applicable.
insulation rlDoes Not
ty) and extends a minimum of 6 in. below
grade. ONot Observable
EINot Appilcable
03,9 Snow-and ice-melting system p Exception: R.. n
^� g m contrails �coo�m lies ... .. Exce Requirement is not applicable.
[FO1211 installed. 0Does Not
EINct Observable
EINat,applicable
_ ,. .............
Additional Comments/Assumptions:
Project Title:Viggiano Residence Report date: 03/31/17
Data filename: C:\Users\Ed\Documents\REScheck\example.rck Page 4 0€10
Additional Comments/Assumptions:
� High Irna (Tier 1) Medium Irrtpa (Tier 2)
Low Imp���(Tier 3)
Project Title: Viggiano Residence Report date: 03/31/17
Data filename: C:\Users\Ed\documents\REScheck\exampie.rck Page 6 of 10
Sectio;
ectionO _... Plans Verified Field Ve..�rfedFFarn'ung / Rough-In inspection Value Vale
Complies?
Comments/Assumptions....�. ...__.
W
..............
402.1.1„ Door U-factor, U U ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FRl]1
❑Not Observable
_ ❑Not Applicable
9 (area-weighted �. ❑Doe P y r es
402.1.1, Glazing U-factor U- U- i❑Com lies See the Envelope Assemblies
402.3.1, average). Not :table for values.
402.3.3,
402.3.6, ❑Not Observable
402.5 ❑Not Applicable
[FR2]1
1303.1.3 U-factors of fenestration _..
[FR41. are determined in accordance
roducts
P e®Complies Requirement will be met.
accordance ❑Does Not
with the NFRC test procedure or
taken from the default table. '[:]Not Observable
.. ❑Not Applicable
....... .._._,,,. ._�._ ..���_��..._.���_ _�_ m ��sos. � w �.�.�.� �.... ..... �_W�.a.....��..................__..M...._ ti
402.4.1.1 Air barrier and thermal barrier ❑Compl'ies Requirement will be met.
[FR23]1 installed per manufacturer's ❑Does Not
instructions. Location on plans/spec:
❑Not Observable ALL WALLS , CEILINGS AND
❑Not Applicable FLOORS
[FR2013
402,43 Fenestration
is listed labeled as meet .. . ._ ......a
built ❑Complies Requirement will be met..
ing ❑Does Not
44 AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code ❑Not Applicable
limits.
.W.. � 9 g ........ �DoespNeS ... Requirem ._.�-.. .�._.
402.4.5 IC-rated recessed li htin fixtures; ent will be met.
[FR16]2 sealed at housing/interior finish ❑ of
and labeled to indicate s2.0 cfm
leakage at 75 Pa. ❑Not Observable
_ ❑Not Applicable
403..2.2. m�_. e .��..... El
4R11 Supply and return ducts attics ❑CompN lies Exception: Ducts located
i[F211 insulated >= R-8 where duct is Doe of completely inside the
>= 3 inches in diameter and >= building envelope.
R-6 where < 3 inches. Supply and: ❑Not Observable
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>=3 inches and R-4.2
for< 3 inches in diameter.
4.03 3.3.5 Building cavities are not used as <❑Complies Requirement will be met.
[FR15]3 ducts or plenums. ❑Does Not
❑Not Observable
❑Not Applicable
403.4 p HVAC pips °Econ chilled fluids luids R R_w.. ..... - ODoNot not PP mpException:
n: equirement is
[FR17]2 ........„
/F below 55 °F are insulated to >_R-
3. []Not Observable
❑Not Applicable
403.4.1 Protection of insulation on HVAC M.. ... __
[FR24]1 piping. Complies Exception: Requirement is
Does Not not applicable.
❑Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R � R- ODompfi s..... - .
P P ies :Requirement will be met.
[FR18]2 _R-3
Not
❑Not Observable
_ ❑Not Applicable
403.6 Automatic or gravity dampers
_... . _ �� _... . .. m m.. _ .. .._....e_.. ,❑DoesNot... .m. �.. q
g � y are; °❑Com lies �Re Requirement will be met.
[FR19]2 installed on all outdoor air
intakes and exhausts.
i❑Not Observable
❑Not Applicable
.. Impact
3) �.. ..
1 High Impacer 1)t(Ti2 Medium Impact(Tier 2)
-, Law Im act(Tier ..
Project Title: Viggiano Residence Report date: 03/31/17
Data filename: C:\Users\Ed\Documents\REScheck\example.rck Page 5 of10
..
lia
Iter I In uPation, I slpecVoi pne� F)eld erlfed aline opllesr miis As opdo s1—C
_. �..-__... .......
303 1 Al installed insulation is labeled mpRequirement will b a met.
��`'GN13]2 or the installed R-values
gar provided. ❑DoNot Req
ENot Observable
......—._...��. ❑Tot Applicable
.. V_� ._.. .v .._ .. R- .. w. �.. oco Not.... table e Envelo A.... .s ..
�'I'02.1.1, Floor insulation R-value. R- p` p Assemblies
402.2.6 ❑ Wood Wood ❑Does
[IN111
❑ Steel Steel '
;❑Not Observable ,
❑Not ApplicaUe
402.2) manufacturer's
.. .. .... �.. w_❑Coes Not ---- �
P -� ❑coin lies Requirement— - . .303.2, ....
insulation installed per will be met.
instructions and
[IN211 in substantial contact with the
�a underside of the subfloor,or floor - ®Not Observable
framing cavity insulation is in ]Not Applicable
contact with the top side of
sheathing, or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
i402.2.6' ;mass wall with R insulation W� ..._.w
❑ Wo � �... p..
-value. If this is a R �� � R- llues� See the Envelope Assemblies
least 1/2 of the od Wood �Ooe Not table for values.
;wall insulation on the wall
[IN311 ;exterior,the exterior insulation ❑ Mass ❑ Mass [Not Observ, bi'e
y requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
i63.2 Wall insulation is installed
� � � � -
manufacturer's instructions.
❑Do� Not Requirement �����•...
•2 taped per
p ent will be met.
lhiot Observable Location on plans/spec:
❑Not Applicable ALL EXTERIOR WALLS
.. .... _.... .....n..._ ��.., .___.., w _.. _ � d _..rv....-.............
Additional Comments/Assumptions: mr�
9 p (Tierlj ...�r2) 3 Lowlmpa._.
1 Hi h Im act Medwm Irpact(Tie �� 3)
..a...,�
ct(Tier ..�.-w�..�
Project Title:Viggiano Residence Report date: 03131/17
Data filename: C:\Users\Ed\Documents\REScheck\example.rck Page 7 of 10
leRcetiotln _
=ie_.tl— f_deW �
Plans ifuedFinal Inspection Provisions ... n.�ValueValueComplies? p..Comments/Assumptions
,
.. mm....�___.......w-� _
402.1.1, Ceiling insulation R R- � ❑Com lies See
-value. R- p ee the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2,
402.2.6 E] Steel ❑ Steel ❑Not Observable
[FI1]1 ❑Not Applicable
303.2.1.1, manufacturer's insulation
al
Ceiling nsu anon installed per ❑Complies :Requirement will be met.
instructions. ❑Does Not
[FI2]1 Blowninsulationmarked every Location on plans/spec:
300 ft2. []Not Observable ALL CEILINGS OPENED
_ ❑Not Applicable DURING CONSTRUCTION
4 2.2 insulation include „ � ���❑Doe plies
402.2.3 Ventedp � ❑Com lies Requirement attics with air permeable will be met.
2 de baffle adjacent
to soffit and eave vents that Not Location on plans/spec:
extends over insulation. ❑Not Observable CATHEDRALL CEILINGS
[]Not Applicable
[FIAtticcc insulationss hatch
lue �
4022..2...4 _.,_... �-;ORequirement will be met„
Does Not :..��..
and door R- R- ^ _ ❑Com lies
of the
adjacent assembly.
❑Not Observable
_ ❑Not Applicable
[02]11.2 Blower
door
ach in mate t @ 50 Pa <=5 —ACH 50 = — ACH 50 - mpIies twill be met
Requirement lb
_ .
1-2, ODoNot
of
n Climate Zones 3-8.
❑Not Observable
❑Not Applicable
[FI3] cf.c ..__ ... � ��... ��.Exception:
Requirement
_.
403.2.3 Duct tightness test result of<=4 cfm/100 c......��
9
fm/100 []Doe pNot nota ticable. wre
ment is
m/100 ft2 across the system or ft f�
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ❑Not Observable
tests, verification may need to ❑Not Applicable
occur during Framing Inspection.
Ducts are prssure
[F 12]2 determine air leakage with
o h ft2 ft
t cf 2 ❑DoesNot not applicable.q ent is__
m/100 cfm/100 ❑Com lies Exce tion: Re uirem —...
1
either. Rough in test.Total
leakage measured with a ❑Not Observable
pressure differential of 0.1 inch ❑Not Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
3.3.2.1 Air handler leakage designated ❑Complies Exception: Requirement is
FI2411 by manufacturer at<=2%of ❑Does Not not applicable.
design air flow.
❑Not Observable
❑Not Applicable
m ........�._,.. _„� ,„.„ �� _ _ ........_..�._
403..1 Programmable thermostats [ lCornplies Requirement will be met. --�
(FI9] installed for control of primary IDoes Not
heating and cooling systems and
initially set by manufacturer to ❑Not Observable
code specifications. ❑Not Applicable
xu..._. . .. .a........ , m ..403.1.2 Heat pump thermostat installed � a -Compli.e.:..s...... Exception: Requirement is
[FI10]z on heat pumps. Does Not
m..
not applicable.
❑Not Observable
❑Not Applicable
[
403
]1 Circulating
,w. .E]Com lies Requirement
i
tin service hot water p q irement will be met.
Z systems have automatic or oes Not
accessible manual controls.
:[-]Not Observable
❑Not Applicable
High Im act(Tier 1)
_w... P
1 .. Medium Impact{Tier 2Low Impact(Tier 3}
Project Title: Viggiano Residence Report date: 03/31/17
Data filename: C:\Users\Ed\Documents\REScheck\exampie.rck Page 8 of10
��.._. ....._ W
l Inspectio"
.: ..
' .. Wcertificate ro ..tins _...p...„aww„is�l.ei..t�fe.� t td .e.�.t.,, .”e
Value F" Compiles? C m n"ts/As �m_
t"i.wo.
nst t "
4l. Compliance posted, kmp
[�I 7) oNot Requirement will be
..
es
met.
T]Not Observable
lVat Applicable
�Corn " �.. .... �_
3033 Manufacturer manuals for � will be met.
Ii1' ,11 mechanical and water heating IJOoes Not Requirement
systems have been provided.
76ti1'ot Observable
NQt Applicable
Additional Comments/Assumptions:
1 f ligh Impact(Tier 1)"� Medium Irrapact ......_W Low Im act ...
� F� (Tier 3)_ ..w.�
Project Title:Viggiano Residence Report date: 03/31/17
Data filename: C:\Users\Ed\Documents\REScheck\exampie.rck Page 10 of 10
se�ffoon
# Final Inspection tioun Provisions � Plans Verified Field Verified Complies? Comments/Assumptions
ments/.Assum tions
Re VICEValue Value Vn
y []Does Not Exception:
applicable.
Requirement... is
403.6.1 All mechanical ventilations stem s
[FI25]2 fans not part of tested and listed le.
HVAC equipment meet efficacy
and air flow limits. '❑Not Observable
❑Not Applicable
403. Hot wate. �� ❑Doe
pig ❑Co spNot notapplicable.
in: Requirement
is
r boilers supplyingheat lies Exception: Requirement is
�[F126]2throughone-or two-pipe e heatin
systems have outdoor setback
control to lower boiler water !❑Not Observable
temperature based on outdoor ❑Not Applicable
_ temperature.
4028j.1.l..dHeated
....�. .�._ ❑Do
y . _.. ,. .� ❑Coe plies Requirement.w et.
water circulations stems m twill be met.
z have a circulation pump.The
s Not
system return pipe is a dedicated
return pipe or a cold water supply, ❑Not Observable
pipe. Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop ;
is at set-point temperature and
_ no demand for hot water exists.
403.5 Electric
ric het IEEE 51.m. �...•� ....we, ..,.... �_ p ... .... �..., pt is
„o. .. _
403.5.1.2 Electric heat trace systems =❑Com lies Exception: Requirement
z 5.1 or UL ❑Does Not nota applicable.
Controls automatically
adjust the energy input to the :❑Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
L.�w..,. piping._
[F13 012 have recirculation pumps
,,.... �.., .d. . . .._._..._ ,,__ ...� _. ,
403.5.2 Water distributions stems that ❑Complies Exception: Requirement is
that
[]Does Not not applicable.
pump water from a heated water
supply pipe back to the heated '❑Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water pdping,to 1049F.
.., . ..- _..... � �... ..• � ,ElDompNot �..Ex eption:le.q
rY ❑Com lies Exception: Requirement is
es
403.5.4 Drain water heat recovery units
[FI31]z tested in accordance with CSA
855.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
m �.. ..... .. w_w— .. ,o ss �... „ . ,•w.0„n ......
404.1 75%of lam sin permanent Opq uirement will bemet.
DoesNoRequirement •
[F16]1 fixtures or 75%of permanent
fixtures have high efficacy lamps.
Does not apply to low-voltage ❑Not Observable
fighting. ❑Not Applicable
404.1.1 no Fuel
gas lig 9 y___...ms have �� ❑DompNot Exception:
a Requirement..—_.. s
..
g s lighting systems have is
continuous pilot light„ ❑ applicable.
❑Not Observable
[]Not Applicable
�...
1High Impact(Tier 1)
p 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
� ._.. .
Project Title: Viggiano Residence Report date: 03/31/17
Data filename: C:\Users\Ed\Documents\REScheck\exampie.rck Page 9 of 10
Energy
2015 IECC
Efficiency
MMIMMENNEVINIUMEM
Above-Grade Wall 21.00
Below-Grade Wall 0.00
Floor 21.00
Ceiling/Roof 49.00
Ductwork(unconditioned spaces):
MMIMMIMEMEMEMMEM
Window
Door 0.35 0.26
MMEMIUMMMOMMUMM
Other (Except Gas-Fired Steam) 80 AFUE
Cooling System
Water Neater..
Name: Date:
Comments
S.C.T.M. NO. DISTRICT: 1000 SECTION:97 BLOCK:6 LOT(S):11
MAIN ROAD
DID
LAND N/F
OF
GLEN L. &DOROTHY L.PETERS
7 *j j fs
PIPE - l.37�
4WOOD L FENCE /ry9 g�yypp@@
� - ® idm Li¢Rg A°STOCKADE
i
� E`d PiP
,–t e wxrwn.. I
1.52' 01
ASPHALT DDrAVAv GARAGE
74X ,Y
I SW FRU,
DWELL NO
m
CQNC. Z•I' uF `3 z
- STOOP
E6.]'
IFON PIN p�
F.J`E vy
0p
AST -10"1 r
d[Y &Ld#sipPP. w
,}
LAND'JfF .� z.�° THE WATER Sure,r, hFLLS OR—t5 AND CESSPOOL
Of 8°srtxxAOE FENCED LOCA 77CWS S OW4 ARE FROM FiftO OBSERVATIONS
JOHN A.&THERESA A.HOFER AND OR QA TA OBTAINED FROM 07HERS.
AREA:24,547.75 SOFT. or 0.55 ACf?ES _-HIS SURVE
ONAUTHOOZ19 ALTERATION OR ADDIRON TO THfS SURd Y IS A iAL7LAnON OF SECTION T2O9 Cb`TTt£NEW YORK STATE£DUCRTION LRW. COPIES t 1HtH SURVEY
MAP NOT BEARMIG THE LAND SURVEYORS EMBOSSED SEAL SHALL NOT BE CON57QERED TO BEA VALID TRUE COFY. GUARRNPEES INQ/CATEQ HEREON THALL RUN
ONLY TO THE PERSON FOR WOM THE SURVEY iS PREPARFQ AND Gi Hf5 SEKALF TO THE TITLE CO§dPANY, GOVFRNAdENTAL AGENCY RNA LENDING FNSnRTT1Ckd
_ LISTED HEREOV,AND TO THE ASSIGNEES OF THE LENQtNO fNSTdT[tTtON, GUARANYE£5 ARE NOT PRANSFERABL£,
THE OFFSETS OR DIMENDONS SHOWN HEREON FROM'1NF PROPERTY LtNES FO THE STRUCniRFS ARE FDR A SPECtFtC PURPOSE AND USF T}1EREFORE THEY ARE
NOT INTFNQEL' TO MONUMENT THE RROprPry LlNFS OR TO OUJQE TN£ERECnON FENCES.ADQtTtONAL STRUCTURES OR AND OTNER 1MPROVFk9FNTS. EASEMENTS
AND/OR SUSSURFACE SRUMRES RECORDED DR UNRFCORQEQ ARE NOT GUARAN JEEQ UNLESS FNYStCALLY EifiQENT ON THF PREMtSES RP niE 1PME OF SURVEY
SURVEY OF:DESCRISED PROPERTY CERT{FIED TO:MIGHAEL VIGGIANO; MINDY SnGGIANG;
FIDELITY NATIONAL TITLE INSURANCE COMPANY,
MAP OF; -
(TITLE #Ftt-7404-82583SUFF)
FILED: METLIFE HOME LOANS, N.A. and SECRETARY OF
SITUATED AT;(.UTCHOGUE 40USING & URBAN DEVELOPMENT,
TOWN a* SOITHOLD
KENNETH M. OyC U L.&
SUFFOLK COUNTY, NEIN YORK a Sa �� and York
s P,O. Oa MrttiEuc o N ,a 119
-_
- PHO (838) ®1688 rAl(891)SP8-16
TILE ill-69 SuALE:"'=30' DATE: JULY 25. 201`1 F.v,s uc No uas rcsore.ee RorAm=L a.reePA—x