Loading...
HomeMy WebLinkAbout40903-Z tlFFO �oG� Town of Southold 2/13/2017 a P.O.Box 1179 a 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38825 Date: 2/13/2017 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 825 Three Waters Ln, Orient SCTM#: 473889 Sec/Block/Lot: 15.-6-14 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/6/2016 pursuant to which Building Permit No. 40903 dated 8/12/2016 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Dolojan,Greg of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40903 01-26-2017 PLUMBERS CERTIFICATION DATED Authorized Signa re �SUF tk� TOWN OF SOUTHOLD BUILDING DEPARTMENT C TOWN CLERK'S OFFICE o . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40903 Date: 8/12/2016 Permission is hereby granted to: Dolojan, Greg 825 Three Waters Ln Orient, NY 11957 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 825 Three Waters Ln, Orient SCTM # 473889 Sec/Block/Lot# 15.-6-14 Pursuant to application dated 8/6/2016 and approved by the Building Inspector. To expire on 2/11/2018. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 ilding pector Form,No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential-$15.00,Commercial Date. �l J New Construction: Old or Pre-existing Building: o (c eck one) Location of Property: X57) 7)M w `-Q_:q� ( ��� O F_=kA� House No. Street Hamlet Owner or Owners of Property: et-C-) ��f'o,1fqlv Suffolk County Tax Map No 1000, Section Block (a Lot l Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ Ap ' ature Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 �., �� roger.richertl-town.Southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Dolojan Address: 825 Three Waters Lane City: Orient St: New York Zip: 11957 Building Permit#: 40903 Section: 15 Block: 6 Lot: 14 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: NRG Home Solar License No: 55690-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency FixturesTime Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: 5.565 KW Roof Mounted Photovoltaic System to Include 21-Trina 265 Panels with 21- M215 Micro Inverters. Notes: Inspector Signature: Date: January 26, 2017 0-Cert Electrical Compliance Form.xls SOUlyolo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) f ELECTRICAL (FINAL) REMARKS: 12 ,1 01-- DATE 7 INSPECTORY;; - �x nrg® bringing homes into the future. C-3 1--3 Home ®� 69 Terminal Street,Albany,NY 12206 p r� 1-800-75-SOLAR ' SOLAR October 11, 2016 Attn: Building Inspector Town of Southold Re: Customer: Greg Dolojan D 825 Three Walters Lane Orient Point, NY 11957 JAN 2 4 2017 Building permit#:40903 EUEL➢)ING DEPT- Dear Inspector, TOWN OF SOUT]ffoLD On behalf of NRG Home Solar, I have reviewed the documentation on the installation of the photovoltaic(PV)system at the above referenced location. This documentation was submitted to me per my request and under my direction. The documentation includes photographs of the installation as well as a quality control checklist filled out by quality control team on October 11, 2016. I have verified that the documentation is complete as requested and that conformance with the quality control plan has been completed to my satisfaction. I certify that the solar system including the panels and system has been installed in accordance with the approved construction documents, manufacturer's requirements, and the New York State Residential Code dated 2010. If you have any questions, please contact me. jr Sincerely, `CSP 41 i Daniel C. Kaufman, PE PE S\ _ Structural/Civil Engineer Phone#: (845)558-6907 Cc: NY Long Island NRGHomeSolar.com FIELD INSkE4N 11�'Ox AAT +CO S ' -- - . ............ CID o ON ROUGH FR4NMqQ PLUIvIBV G IN ULATXON•PEA N.Y. S , STATE ENBROY CpAE FINAL , Q ?lf •M it }.f _AOLD BUILDING PERMIT APPLICATION CHECKLIST -YEPARTMENT Do you have or need the following,before applying? riALL Board of Health THOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: 631 765-9502 Surve Y SoutholdTown.NorthFork.net PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined Al ,20 Storm-Water Assessment Form Contact: Approved ,20 Mail to: Disapproved a/c Phone: Expiration ,2 D ��L5 O V L5 B m spector PLICATION FOR BUILDING PERMIT AUG m 5 2016 Date ,20 - INSTRUCTIONS WELDINGDEPT. 45 a. i1&e§6 &lb completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.if no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws, Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Sigrikumflo6f applicant or name,if a corporation) t70 WZt,BUF-PC01 C P Sr-e I O(S (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Name of owner of premises (� 120L_a�Tpt 1�,s (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. 15545S-1 Plumbers License No. Electricians License No. SS&Q6 - �.L-&- Other Trade's License No. 1. Location of land on which proposed work will be done: V5 'THQ£'E 1A)AT LAk�C! r-v.,r- House Number Street Hamlet County Tax Map No. 1000 Section 145 Block Lot Subdivision Filed Map No. Lot z existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancyLC�_ E$ �� b. Intended use and occupaney ,NC. 3. Nature of work(check which applicable):New Buildin"gAddition Alteration Repair Removal Demolition Other Work—E,o(;g(Z T)IOA3&.T 4. Estimated Co d5$2 Fee (Description) (To be paid on filing this application) 5. If dwelling, mber of dwelling units Number of dwelling units on each floor If garage, n tuber of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front ' Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10.Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO 13. Will lot be re-graded?YES NO Will excess fill be removed from premises?YES NO 825-rHi2;ewAic-eSAr 14.Names of Owner of premises Addressor, NfN 015-7 Phone No. q7•�D�° Name of Architect Address Phone No$FBS •5SZ_�®�l Name of Contractor N Addres """ "��e. y�Ac�Phone No. ¢ 6�-s 70 i p &HewtAf i r7f �1 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C.PERMITS MAYBE QUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OVf j�(OA� c being duly sworn,deposes and says that(s)he is the applicant ame of individual sigmng contract) Bove named, (S)He is the (Contractor,A ent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this Si,14 day of A U IA(,T 201 Cp Notaryubl' TATR OF N¢w YORK Signat ant �jOTA Y poilL{C-R No. p1 MAe225S1" QupHtlid in $yfto{k 6ouKtY s McY 26.10119My Commission Expire Scott A. Fussell ,��°sul��� ST 1R.MMAT E K SUPERVISOR C MA.NAGl]EMIENT z SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORD SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT INVOLVE ANY OF THE FOLLOWING. Yes No (CHECK ALL THAT APPLY) ❑UA. Clearing, grubbing, grading or stripping of land which affects more ❑Wthan 5,000 square feet of ground surface. B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑ C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑ . Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑ , Site preparation within the one-hundred-year f loodplain as depicted on FIRM Map of any watercourse. ❑ F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one.or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT (Property ODesProfessional,Agent,Contractor,Other) S.C,T.M. : 1004 Date i n District NAME- Section Block Lot s" Contact information: �j, �yp **** FOR BUILDING DEPARTMENT USE ONLY**** lfl `��5�7� Reviewed By: - - — — — — — — — — — — — — — — Date: Property'Address/Location of Construction Work: — — — — — — — — — — — — — — — — — 2IM Approved for processing Building Permit. 1 Stormwater Management Control Plan Not Required. l Stormwater Management Control Plan is Required ❑ (Forward to Engineering Department for Review.) FORM * SMCP-TOS MAY 2014 !o OF S Town Hall Annex Telephone(631)765-1802 54375 Main Roada_q R� P.O.Box 1179 Q ro erAchertown sos o .n .us Southold,NY 11971-0959 ' 01 BUIMING]DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: Company Name: LA LS%AJL= Name: License No.: ,� G Sh —M17-- Address: /1b f'0c>::�;" 7/ Phone No.: 631 qt(052 JOBSITE INFORMATION: (*Indicates required information) *Name: QLD 6� *Address: *Cross Street: *Phone No.: 17 'l6? gqq Permit No.: 03 Tax-Map District: 1000 . Section:j Block: Lot: *BRIEF DESCRIPTION OF WORK(PI se Print Clearly) (Please Circle All That Apply) *Is job ready for inspection: YES/ NO. Rough In Final *Do you need a Temp Certificate: YES/ NO Temp Information(If.needed) *Service Size: 1 Phase 3Phase 100 150 200 300 360 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 8241eWest for Inspection Form 4j1 n rg® 170 Wilbur Place.Suite 100.Bohemia.NY 11716 Home 1-800-75-SOLAR p SOLAR August 5, 2016 Solar Panel Installation Dolojan Residence 825 Three Waters Lane Orient, NY 11957 Dear Sir/Madam: Please find the following attached documents for the Dolojan Solar Photovoltaic Installation at 825 Three Waters Lane Orient, NY: • Check made payable to the Town of Southold for the fee of$200 • Two (2) original Southold Building Permit Applications • Application for Certificate of Occupancy • Application for Electrical Inspection • Stormwater Management Worksheet • Four (4) Sets of stamped and sealed architectural plans with spec sheets • Roof Diagnostics Solar's Insurance Information,including Workers Comp, Disability,&Liability documents. • Copy of ME License Please do not hesitate to contact me with any questions or concerns. I can be reached at 631-416-5525. Sincerely, Jaim Co Permitting Specialist NRGHomeSolar.com STATE OF NEW YORK WORKERS' COMPENSATION BOARD CERTIFICATE OF NYS WORKERS' COMPENSATION INSURANCE COVERAGE la. Legal Name&Address of Insured(Use street address lb. Business Telephone Number of Insured only) 800-757-6527 Roof Diagnostics Solar and Electric of NY,LLC 1 c. NYS Unemployment Insurance Employer Registration dba NRG Home Solar Number of Insured 170 Wilbur Place Suite 100 50-39533-4 Bohemia,NY 11797 ld. Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured (Only required if coverage is 454175140 specifically limited to certain locations in New York State, i.e.,a Wrap-Up Policy) 2. Name and Address of the Entity Requesting Proof of 3a. Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) Federal Insurance Company Town of Southold 3b. Policy Number of entity listed in box"la" 53095 Route 25 004 4727794 02 PO Box 1179 3c. Policy effective period Southold,NY 11971 04/01/2016 to 04/01/2017 3d. The Proprietor,Partners or Executive Officers are X included(Only check box if all partners/officers included) ❑ all excluded or certain partners/officers excluded This certifies that the insurance carrier indicated above in box "3" insures the business referenced above in box "la" for workers' compensation under the New York State Workers' Compensation Law. (To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers' compensation insurance policy.) The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The Insurance Carrier will also notify the above certificate holder within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise, this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in box"3c",whichever is earlier. Please Note: Upon the cancellation of the workers' compensation policy indicated on this form,if the business continues to be named on a permit, license, or contract issued by a certificate holder, the business must provide that certificate holder with a new Certificate of Workers' Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Robert Drew,McGriff,Seibels&Williams Inc. (Print name of authorized representative or licensed agent of insurance carrier) Approved by: V 3/31/16 (Signature) (Date) Telephone Number of authorized representative or licensed agent of insurance carrier: (205)583-9543 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2 Insurance brokers are NOT authorized to issue it. C-105.2(9-07) tq-10%20.1 STATE OF NEW YORK WORKERS'COMPENSATION BOARD CERTIFICATE OF INSURANCE COVERAGE UNDER THE NYS DISABILITY BENEFITS LAW PART 1. To be completed by Disability Benefits Carrier or Licensed Insurance Agent of that Carrier I a. Legal Name and Address of Insured(Use street lb. Business Telephone Number of Insured address only) (800) 757-6527 ROOF DIAGNOSTICS SOLAR AND ELECTRIC OF NY LLC lc. NYS Unemployment Insurance Employer registration DBA NRG HOME SOLAR Number of Insured 170 WILBUR PL. SUITE 100 BOHEMIA, NY 11716 ld. Federal Employer Identification Number of Insured or Social Security Number 454-17-5140 2. Name and Address of Entity Requesting Proof of 3a. Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate NEW YORK STATE INSURANCE FUND Holder) Town of Southold 3b. Policy Number entity listed in box"la" 53095 Route 25 DBL 6523 96 -4 PO Box 1179 Southold, NY 11971 3c. Policy effective period: 08/07/2016 to 08/07/2017 4 Policy covers: a. ® All of the employer's employees eligible under the New York Disability Benefits Law b. ❑ Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability Benefits insurance coverage as described above. - Joseph J, Masl., Date Signed: 8/1/2016 By Telephone Number. (866)697-4332 Title Director of Disability Benefits Insurance IMPORTANT: If box"4a"is checked and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder If box"4b"is checked,this certificate is NOT COMPLETE for PURPOSES OF Section 220, Subd.8 of the Disability Benefits Law,it must be mailed for completion to the Workers' Compensation Board,DB Plans Acceptance Unit,20 Park Street,Albany,New York 12207 PART 2. To be completed by NYS Workers' Compensation Board(Only if box 11011 of Part 1 has been checked) State of New York Workers'Compensation Board According to information maintained by the NYS Workers' Compensation Board,the above-named employer has complied with the NYS Disability Benefits Law with respect to all of his/her employees. Date Signed By (Signature of NYS Workers'Compensation Board Employee) Telephone Number Title Please Note: Only insurance carriers licensed to write NYS disability benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1(5-06) I ® DATE(MMIDD/YYYY) AC40Ro CERTIFICATE OF LIABILITY INSURANCE 03/30/2016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Destro Soria MCGRIFF,SEIBELS&WILLIAMS,INC -NAME' y CNo.PO Box 10265 AIExt). - - aC No): Birmingham,AL 35202 E-MAIL ADDRESS dsoria@mcgriff com INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:SCottsdale Insurance Company 41297 INSURED INSURER B:Starr Indemnity&Liability Company 38318 Roof Diagnostic Solar Holdings,LLC Roof Diagnostics Solar&Electric of NY,LLC dba NRG Home Solar;NRG Residential INSURER C:Federal Insurance Company 20281 Solar Solutions,LLC; 170 Wilbur PI.Suite 100 INSURER D-AXIS Surplus Insurance Company Bohemia,NY 11716 INSURER E INSURER F• COVERAGES CERTIFICATE NUMBER:SD9ZPTUL REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL S BR POLICY EFF POLICY EXP LIMITS LTR INSD WVD POLICY NUMBER MMIDD/YYYY MM/DDIYYYY A X COMMERCIAL GENERAL LIABILITY NCS0000830 04/01/2016 04/01/2017 EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE a OCCUR PREMISES Ea occurrence $ 100,000 MED EXP(Any one person) $ excluded PERSONAL&ADV INJURY $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 4,000,000 JERCT 7 LOC -PRODUCTS $ 4,000,000 POLICY a OTHER, $ B AUTOMOBILE LIABILITY SISIPCA08335016 04/01/2016 04/01/2017 COMBINED SINGLE LIMIT 1,000,000 Ea accident $ X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ X AUTOS AUTOS NED PROPERTY DAMAGE $ HIRED AUTOS AUTOS Peracadent Deductible. Comp/Coll $1,000 D UMBRELLA LIAB X OCCUR ELU782570/01/2016 04/01/2016 04/01/2017 EACH OCCURRENCE $ 5,000,000 X EXCESS LIAR CLAIMS-MADE AGGREGATE $ 5,000,000 DED I I RETENTION$ $ C WORKERS COMPENSATION 0044727794-02 04/01/2016 04/01/2017 X I PER OTH- AND EMPLOYERS'LIABILITY STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE � N/A E L EACH ACCIDENT $ 1,000,000 OFFICERIMEMBER EXCLUDED? (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Certificate Holder Is Additional Insured under General Liability as required by written contract CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold 53095 Route 25 AUTHORIZED REPRESENTATIVE PO Box 1179 Southold,NY 11971 Page 1 of 1 ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD peneny of mo S .rt k DeV_of briar.Ucenal.0 SUFFOLK COUNTY-OEM OF LABOR, a LICENSING&CONSUMER AFFAIRS' AddWonal Ousm's a MASTER es N me"s ELECTRICIAN JOSEPH P STRIANO ' mrsnnsaau¢, - •k - _" _ = — -". -'� - LIGOSQ Category r' This certifies that the, ROOF otAONosTics SOLAR AND t i bearers duty ELECTRIC OF NY LLC DSA L licensed by the - County of Suf(olk - r/ 55690-ME 08811712015 ; '080112017 n r /,S,i'. r `s'S�`., � .r,�5 _J`'� ,5.°r� .;�J:✓��.v..• "� y, xp. .;,t- "`-•. K. r..�`•S'.s:�•`;r:t ..r•" �..�.�. ",s„ ,. , ':'J. 3.'%, ;.:a ',,. , ri_-'R" •.k •x...- yyy ,'•4;e .�,�� r aG:t 7r t ;.,6 '�. .q'• 4..r\ _Jnr .. .+' .. ..:, r..t 44 J} i 1:. Ir�tY'Y 5.•, ,,�,,.`�7'`"'. f .Yk. .i,._ •,Y Y.: ;� . .�+',,{r. t�Lr,q.�...._._: 3s,,,: , � ..-..f• ,. !�;�rn ."-"' ,1.+�-ti•;. �CY:�;• �Ft� �.4,„oR •,{, s G�� :ve.�'u.� 4.. -f ,�$�� /. ..\�., . r... .,-��; ....tr tix- ,t:�"»•rs:s:�;�'�, ..�.a.^,t•nvsR �'v. �,� .;�,�•�� �,� A�-` ,'t��.e..,..., �, r�., :,1�F`. � ..tx�°.Y{+i' �, ,;,�•�:ch�,�r., `i.�.'.s! �.C, ;yf. ,J_rr•I=Rm�; ,q ., T. -r. "t 1 c- ,.•,.tr :nr t� t .i. ,.t .� � " •,. ,11 f� .r ,A_ � l .� ��Y. .•s,!, �, s •fit h ti• a,Q'�„ ,-.« Ili �: �,�. \J-I,)�- .�_ra ?:7i\ /. � -\• ftp".t� �� ,�„. �) k fq-••.�: .�� l aw ..,.� / r�;fix:. �\.!. �a•� 1.1t)_ f;, •v.. 1. itis. ...�-..�•��� a{{ ^+.t ¢tix..f {F .t�. � (� G..�..7�r..�. r„ :•i• -•�r..'...1..r�� J, .f: i(,. • �Y F ,..�... ^ ems �i .�::. '17'b A ,,-...«t5� y . i..• ,, .+I: A �7•�•)',l7 *f t:.?.y •+ ... r�. .`S,?.r,.,.... ,:�-,{•�. ':.:1�:,f'.,�FS •,;:l.�-•,• ;.Y .,�i`'.�u,� ,�s 'i Y•�..-,«. -�2. /::./jy f'�.t. s„ �i � �s�t +G,_ �` c: .. ,;;�f�'1 _ .-ni— i• .^`:F f!.;. .:-,�,�,�•�, •_.k.X..:_`-.-=:Cti:�'�j�"�.s:.�!:r..:��L��j�,.t ' ,.!,?.1�.�'"s'3i., %•:''d�,t��.J`� � 3 r� '_',,},; `K.�/{_z C: .;�,�•,�5•..:�Yq _SLS" jl�Ch"` ` iF' �'v+.:-r:<.•nua,.ewc✓w...rrYsu.�:::..n�«wr...,.rwv:+•..t:>:: -+uaa i?vu�c.E+w-s:E":s.:au^+.rs:r-n>—u,ive�1vw+ Aw.:.n•- �u,..<.vew».v.,site s... ,.-` '7z"` 7v��' SlF`�- �J$.+ _ «34.�.•.�aw",.v vr'n`nit w... . -v sw""Ti...y�_w -=J Ig. , , lfNitMi �` ��+.�� � � fir•- � *; Iw 701 $•1 \.x 3 ��'•� 4 91 � Nj S. ��.��r.:.r:r.rt:s«,.�•A•r. ::-a.r..s a+:r s.nr,ss,.zr� v�..n �+r:a.,has- r� -.•.ter•: xn, .,n:wr.--.. -»�ao«ax+cac ....s,-.nr � _ - x . ? il]_ 1 ? ��,� } � •P• ..� ,:+.r,. 'I.�-• _i i _. ..Y' -�r a���i� .`k;=ag _ u', rman.-'"`3^ _�:�.e.r.�,- :,., _„�t�Yr'_•Y.'. '. ✓t .l'tr ...nl a t __-. ..,]�, r.. y.. „. -• __ •4"^.. _.�� ,. -•.'s±:trf..� �» ,,-,C� t... .; -ij"T i - 4.sr•"^__: .}I! ,,..: ., .� _,.7.t„ 1�,r. ._. �•:_:.,,�.,: --..�2� �,-.:.. } ., ��1c• -, .h, t.' �i '^,y;-` .,�,.....t. -�. .S, -i' .�'y+�., •1. A �. _ r.�•,. .:5., /' ...\. .d,, 1 • h9'��+ .•�. 1- NSA .r'. F- r�: �� .� +i, � ��. �:•� G Jr� .?."- 3't4. .�I r l J'. `•i J 4 .i` ,\ a In J" r t terg- 4 . _ LY` ! \\ �:s r,'�' •,t ., r t?�I l� f:r c :,ti. ,� „>y I rte/`. _, } `4/"., ._«.ul, l L,;,-:. t 4, »wrr 51 t,)•'fir. ,•,. t, t�•. !'! :\:1 •�. �.' 'G��1 51i. .y•.7 :.e..j l9 , moi ., -;- a7••stunk:,7+%,�- ,ry,,; ,;;yw:.- '�' f-.:':ti1':...1� J - �� .;yS;rJ+;.J�. i-, +:�d}�! A �r,:"'^• ,.., ,L •r`'»l .Gr. ,. s:� ..! rA' , -\•, 5q F,.z�. � :�_�• ,: uJ. �� ,{'t, ..•�il;'7"'�!�W�s�'..1.tYcia ',A,,, .�. �:.+ts•.:,,,�, S�+.� �, ,sa -:.5' *"ti.'.;.t;�:+'.vt� u•. ," �.y, .t, '.�+t � � �':: �k' .t• 5�5. .V.,?''S�- y+. AnAY•,, J � ��1",��N y. i'"-yr--- v, {4';..1_1 at�.,Z.r ..5. �w,ll�� •,tl:•• 2. •33,� .;1�}ai r: ;,;-%;.-!_ \x� t�1^{r��.�• G�./ f -4,,e't.{, #5't �r\.k' •r,. -••• .�, ,�< „s C� h 'Mt p• f SSt /" .' �. A;v,Nl�,t• \` r�/s:� +' {ar,,. �. ,�, Im �t.�.,:;, .l,aya: L�;� .:�,5:,.��•.. `hfi ,. '�=�1�=�' ,;.: ! A� +'.f���'1.eC�. �'r�i�1i���'?�t.-/�0i l��y� �•�� �1+�'•�;`� A� `M ,43: STD DATE: P.# l) - OCCUPANCY OR FEE: gY USE IS UNLAWFUL NOTIFY 5- 2 BUILDING O D4 PM FOR THEY WITHOUT CERTIFICATE FOLLOWING INSPECTIONS: I. FOUNDATION - TWO REQUIRED OF OCCUPANC ' FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOU C.O. ALL CONSTRUCTION 'SHALL MEET THE ELECTRICAL REQUIREMENTS OF THE CODES OF NEW INSPECTION REQUIRED YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 COMPLY WITH ALL CODES OF OF THE TOWN CODE. NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF MuI D - ` RN�bSTEES N:1�EC— all , 0 ,' nrgo bringing homes into the future. ® Hom� 69 Terminal Street,Albany,NY 12206 SOLAR 1-500-75-SOLAR August 2,2016 Re: Dolojan, Greg Residence 825 Three Waters Ln Orient, NY 11957 Jurisdiction:Town of Southold Attn: Building Official This letter is to inform you that Daniel Kaufman, PE has performed a structural analysis of the roof for the house referenced above. The analysis was performed to determine if the existing roof system is structurally adequate to support the new photovoltaic modules in addition to the code required design load values applicable in the 2010 New York State Building Code. The PV system will be flush mounted, parallel,and will be no more than 6" above the roof surface.The weight of the system will not exceed more than 5 lbs/sq ft. Our analysis is isolated only to the areas where the modules are intended to be placed. The modules are to be located on the following roof planes: SP# Rafter Size Rafter Spacing Rafter Max Span Total Width of Roof 1 2 X 6 16 inches 14'-5" 14'-11" Each roof has been analyzed with design loads as follows: Ground Snow(Pg) =20 psf Wind Speed (V)= 120 mph SP#1 It has been determined that the roof structure is adequate to support the new PV modules in addition to the code required design loading. Attach the module rail brackets to the roof with 5/16" lag bolts at 32"OC max.with a minimum penetration of 2.5" into the wood members. The roof was inspected from the interior and exterior to determine the existing conditions. We have determined that the existing roofs have 1 layer of shingles on the roof surface over the plywood sheathing. It is a violation of NYSED 7209 for any person, unless acting under the direction of a licensed professional, to alter an item in any way. If an item bearing the seal of a licensed professional is altered, the altering licensed professional must attach the notation 'altered by' with his seal,signature,date of alteration,and description of the alteration. If you have any questions regarding this analysis or the construction documents, please feel free to contact me. Sincerely, OF �rF� -.q K0 !� Daniel C. Kaufman, PE �`F =LyN -- Structural/Civil Engineer la ;11 Z a Phone#:'(845)558-6907 Cc: NY Long Island \ o " } r NRGHomeSolar.com nr °" DOLOJAN RESIDENCEy -i M '.�''r- � x':u,'>""si...:::.?s4-V;.x�.,;-•';µ'�•{,�''-�(r.�:°'- � W ho Home 5. 65 kW DC PHOTOVOLTAIC SYSTEM 5 ( ) .. .3 825 THREE WATERS LN ORIENT NY 11957y -m� _ SOLAR ro> }y�`,hnr *,�-F��.'�`cy, -.�:,i.�Q�F rc:.:v;.0•.�. ' S`�yi�: •kY .� , u K �- _"�'--�.:c`�-.,yam.' - '�_r`,,.� 1a�����,�9.=bks'�3.{'�r�:'•`"'-,�;= _4fL,� V�y_ '� ,tl.„}fes •2-" ,ah*,".t*"' °3 _ , ;.. w°amz�o\ �-h ��.. a-_ = ,-' •�R«. �'� <s5 r•..,. h�;,r$#.'4��'�" �Y'= o Z c'3�z�t rkq !'a;;�,r4�:.sk�� _>S'��5:=$�-#..zTt.•��t#s�.''S�<=sr SCOPE OF WQRK: s ;@,< a CD� 21 TRINA SOLAR MODULES SOLAR PANELS Y E, p m L SOLARtm,4ELS v w o:� o., 21 - M-215-60-2LL-S22-IG INVERT �� z q^ 1 - INVERTER\,� I 21-TSM- 265-265 ROOF TOP AND WALL MOUNTED ELECTRICAL�EQUI�MENT a'w C�/Mr z \- • - 'oowF SOLAR PANELS REQUIRED PER CODE,AHI&FIRE DEPARTMENTS 4� Vzf,-P w z CONNECT TO 200A/ 200A MAIN SERVICE PANEL `' �'a¢ o�_ (N)JUNCTION BOX o 5 O o N o TOTAL SYSTEM SIZE 5.565 kW(DC) �, EXISTING 200A BUS EXISTING SHEET INDEX: E m 200A TOP FED MAIN REAKER ® E1 - SITE PLAN E7 - SINGLE LINES SERVICE POINT(INSIDE) oo E2 - NOTES E8 - ELECT. NOTES ® a E3 - PROPERTY PLAN E9 - SIGNAGE EXISTING SERVICE POINT E4 - ELEVATIONS E10+ - CUT SHEETS &UTILITY METERING E5 — ROOF PLAN (OUTSIDE) F6 — QFTAIIS VICINITY MAP (N)60A AC COMBINER PANEL BOX(OUTSIDE) :t� 8::s^� F"A t-Y ' :,; "=-• r ,.f N ° "<_< (N)60A AC DISCONNECT 240V NEMA-3R(INSIDE) NR,,, t•. ..,.>xS,9 n''a'k'^ -'�� ;r?r,�^�.'ati'"ps`,�° `;T`' m C � ry g \ s Y�fi:�-•-sT�F -iZ'e.3 '.^�4•.-'�cr.�r£:;_ ;t i���i .i1; yr9�"i�""�--�.c N f lf<'v - - -- x.�fi[' _ -_ -_ .�,+e:'•'s�'.,"" =e�"i ma W � � w SITE PLAN `.ate �a�,r �f � ',-1 � ,•_;- .y, _ ,.:�d='= - SCALE:3/32"=1'-0" _" _ •`- ''"'�'-�='..:=.,, e'fs1'ae kens..�,.ua-_�- -".,L.,;•.- NOTE: ALL SCALES SET TO 11X17 SHEET SIZE SOLAR PHOTOVOLTAIC SYSTEM NOTES: ABBREVIATIONS All materials,equipment,installation and work 9.All conductor exposed to weather shall be 22.Flexible,fine-stranded cables shall be A AMPERE LU shall comply with the following applicable codes: listed and identified for use in direct sunlight. terminated only with terminals,lugs,devices or AC ALTERNATING CURRENT J=1 1, FJ 3 AHJ AUTHORITY HAVING JURISDICTION o mt m 2015 IBC [NEC 690.31(C),310.10(D)] connector that are identified and listed for such use. 28 BLDG BUILDING = r,� 2015 IRC 10.The module conductors must be type USE-2 [NEC 690.31(H)] CONIC CONCRETE 5 m e 2014 NEC or listed for photovoltaic(PV)wire.(NEC 23.Connectors shall be of latching or locking type. CB COMBINER BOX s a 2012 UMC 690.31(C)) Connectors that are readily accessible and operating CEC CALIFORNIA ELECTRICAL CODECu COPPER t „ 2012 UPC 11.All conductors shall be marked on each end at over 30 volts shall require tool to open and shall DP DISTRIBUTION PANEL x'' 2012 IFC for unique identification. be marked"Do Not Disconnect Under Load"or"Not Dc DIRECT CURRENT EGC EQUIPMENT GROUNDING'CONDUCTOR '"1 2013 Building Energy Efficiency Standards 12.All grounded PV DC conductors shall be For Current Interrupting".[NEC 690.33(C)&(E)(2)] (E) (EXISTING) � •" .�w m�✓�� v Authority Having Jurisdiction properly color identified as white.[NEC 200.6] 24.Equipment grounding conductor for PV modules FV FIELD VERIFIED l LU Fire Authority Having Jurisdiction 13.PV system connected on the load side of the smaller than 6 AWG shall be protected from h sical GALV GALVANIZED C� p� a ty g y p p Y GEC GROUNDING CTRODE CONDUCTOR-- w x-9 service disconnecting means of the other damage by a raceway or cable armor.[NEC 690.46 GND GROUND j �� c` i�_ a m , \ 1.Existing plumbing vents,skylights,exhaust source(s)at any distribution equipment on the &250.120(C)] HOG HOT DIPPED GA_ VANIZED f c z�'a Z� outlets,ventilations intake air openings shall not premises shall meet the following 25.Fine stranded cables used for battery terminals I CURRENT CO g[NEC[ ry Imp CURRENT A�MAX POWER; _a4 T �� ' be covered by the solar photovoltaic system. 705.12(D)]: devices,and connections require lugs and terminals INVF INVERTER � ,y U .' ' '' G ' 2.Equipment.Inverters,motor generators, 14.Each source connection shall be made at a listed and marked for the use.[NEC 690.74] ISC SHORT CIRCUIT(CURRENT photovoltaic modules photovoltaic panels,ac kW KILOVOLT AMPERE p ,p p dedicated circuit breaker or fusible disconnecting 26.Grounding electrode conductor will be kw KILOWATT photovoltaic modules,source-circuit combiners, means.[NEC 705.12(D)(1)] continuous,expect for splices or joints at busbars Lew LOAD BEARING WALL`:. yO o W' I_ and charge controllers intended for use in15.The sum of the ampere rating of the within listed equipment. MIN. MINIMUM (S��� °z g '?,. MCP MAIN CIRCUIT BREAKER w �W Photovoltaic ower systems shall be identified overcurrent devices in circuits supplying Power to [NEC 250.6`KC)] MSP MAIN SERVICE PANEL�`�� O-o w- -' and listed for the application. (NEC 690.4(D)) the busbar or conductor shall not exceed 120% 27.All smoke alarms,Carbon monoxide alarms and (N) (NEW) a M 3.All outdoor equipment shall be NEMA 3R rated g [NEC3R NEMA 3R,RAINTIGHT OUTSIDE RATED u! c o eq p of the rating of busbar or conductor. NEC audible notification devices shall be listed and to o w including all roof mounted transition boxes and 705.12(D)(2)] labeled in accordance with UL 217 and UL 2034. NEC NATIONAL ELECTRICAL CODE NTS NOT TO SCALE y o Z S i Z w -) switches. 16.The interconnection point shall be on the line They will be installed in accordance with NFPA 72 OC ON CENTER M€ o°=� 4.All equipment shall be properly grounded and side of all ground-fault protection equipment. and NFPA 720. [IRC 2013 P314&R315]. OCPD OVERCURRENT PROTECTION DEVICE o 0 N o bonded in accordance with NEC article 250. 705.32 28.Smoke alarms and Carbon Monoxide Alarms will P POLES TBREAKER POLES- g p m [NEC[ ] PL PROPERTY LINES ❑ 5.All circuits connected to more than one source 17.Equipment containing overcurrent devices in be retrofitted into the existing dwelling.These PV PHOTOVOLTAIC shall have overcurrent devices located so as to circuits supplying power to a bus bar or Smoke alarms are required to be in all bedrooms, PVC POLYVINYL CHLORIDE w provide overcurrent protection from all sources. conductor shall be marked to indicate the outside each bedroom and at least one on each RR ROOF RAFTER p p i SPC SOLID BARE COPPER a [NEC 690.9(A)] presence of all sources.[NEC 705.12(D)(3)] floor of the house.Carbon Monoxide alarms are SP SOLAR PLANE 6.All photovoltaic P modules shall be mounted 18.Circuit breaker,if backfed shall be suitable required to be retrofitted outside each bedroom and SPL SUBPANEL P ( � i i �1 SCH SCHEDULE on the roof.Additional equipment of the PV for such operation.[NEC 705.12(D)(4)] at least one on each floor of the house.These ss STAINLESS STEEL system shall be located outside the building near 19.To minimize overheating of the busbar in alarms may be solely battery operated if the PTC PRACTICAL TESTING CONDITIONS a the main eleccal services.[NEC 690.13(A)] panelboard,the panelboard main circuit breaker Photovoltaic project does not involve the removal of � C IILARALWATER HEATER tri 7.The utility interactive inverters shall and the PV power source circuit breaker shall be interior wall and ceiling finishes inside the home, LINO UNLESS NOTED OTHERWISE automatically de-energize its output to the physically located at the opposite end of the otherwise,the alarms must be hard wired and V VOLT connected electrical production and distribution busbar[NEC 705.12(D)(2)(3)(b)]. interconnected. Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT , network upon loss of voltage in the system and 20.All the NEC required warning signs,markings, IN WATT ° shall remain in that state until the electrical and labels shall be posted on equipment and production and distribution network voltage has disconnects prior to any inspections to be J been restored.[NEC 690.61] performed by the Building Department inspector. $ 8.Due to the fact that PV modules are energized 21.Metallic raceways or metallic enclosures are whenever exposed to light,PV contractor shall required wiring method for inside a building for disable the array during installation and service PV system.[NEC 690.31(G)] a $ by short circuiting,open circuiting,or covering the array with opaque covering.[NEC 690.18] •OCCUPANCY TYPE: R-3 BEEfNp •CONSTRUCTION TYPE: TYPE V-13 E2 •UNSPRINKLERED A -125.21' W w� W m M 1 �I \ , Z • 1 f WN��v J 1j 0 W W 75._1.. �� N W= � , P zc�m �a g. Lj c trJ \Q< O Ci. w -�C o rn w ® r.. Na_ -�0DQY o_W 0003Z FA � Z u�i�_w z N ® CA MW 0 0� O 00N r allo co 0 0�_9�� o W QQ a x N _ o C' N PROPERTY PLAN y �. SCALE:3/32"=1'-0. —y 25.24.' E 3 \ ® ; -i lit ){ \ zy/ \\ | ` —Z . )- {� § � B ,z g� 2• Ed f » k �|�t� � S-, /Lu �§ ®� g Lu7 al§ § )2k� al � 5��\ § zwpwz §3[§ |2 ecm _ 0 co � N § § S ! ! _ § ; | ) § 2 � \ k � � � ( ( ( ,j � � ` ■ | | ® § | , ELEVATIONS SCALE: _ ` E4 OOF#1 PITCH AIIMUTH MATEIML SP SQ FT ARRAY SQ.FT RAMRS SPECS RAFTERS MAX SPAN MAX ATTACHMENT SPAN LAG SIZE SHADE 300 257° CAMP SHINGLE 687 369.81 2"X 6"@ 1611O.C. 14'-5" 32" 5/16' "SS 870/o a a 'm 81, 0 \ ai:3ul cif crvt ClJ � N. 1JI ' C1 Z Y _ Ali L! C-) = UJ Cn = co LLJ l fes'..=''—• � Q _11,wLu di 61 ATTACHMENTS ~ 32"O.C.MAX.(TYP.) . ° wo^w ARRAY Z Lor-W z u�a-Qj =0 `d O o U) & 0 "No a 0 U � W OO l C1 � C O 8 N a NEW PV CONDUIT TO BE RUN WITHIN ATTIC AND HIDDEN FROM VIEW. CONDUIT TO BE PAINTED TO MATCH THE EXISTING SURFACE. x G � N ROOF PLAN o SCALE:1/8"=V-0" o a s s EQUIPMENT LEGEND ❑ACCESS ce COMBINER O D JUNCTION nm C DISCONNECT w/ om DC DISCONNECT w/ O LOAD CENTER w/ O DISTRIBUTION PANEL • WALL INVERTER w/ O DEDICATED PV ❑ SERVICE POINT& �� LADDER ❑BOX ❑BOX ARNING LABEL ©WARNING LABEL ❑�c WARNING LABEL or w/WARNING LABEL WARNING LABEL M SYSTEM METER "P UTILITY METERING BRANCH LEGEND B1 - BRANCH 1 W To t O B2- BRANCH 2 Q s .I eg X38 a= ' 3w� �> tp pe , -- 11�� o e 1� P ;O j e>,`., vz 11 E z „w a �� o�W� W. T �M¢Y N w° � o W F N O Q Q K W N t it Ho 0 �O 0O m � U W K v-, a N D O � F � N N `C F Naa STRING PLAN SCALE:3/16"=1'-0" E5.1 PV MODULE UNIRAC SOLARMOUNT GROUND WEER & RAIL WITH ECO FASTEN MODULE CLAMP m L-FOOT w a 5/16- EPDM BONDED PV MODULE 021 ` 304-18.8 SS WASHER COMP SHINGLES a-_ � gm L-102-3" BRACKET'S (OTHER- ~" � GREEN FASTEN FLASHING: OPTIONS AVAILABLE) t > ECO-Gf1-BLK-812 WffH a r GF-1 'FLASHING ECO-CP-SO COMPRESSION BRACKETLL ,'. Qo >2 y 2t �LW 5/16"x4" S.S. LAG BOLT �,. ^- LAG BOLT 5/16- U� 0 2-r / WITH 2.5" MINIMUM ma O 6 (TO BE VERIFIED) PENETRATION SEALED w x WITH APPROVED SEALANT O '" ozma� (TO BE VERIFIED) C, STANDOFF DETAIL -�`W- o-U o 2 SCALE:NTS Z o y W v m o W Ha W (M¢> EXISTING 200A BUS o o Z o � �p�WF EXISTING 200A MAIN BREAKER q Q o =W 120/240V 1� 3W MAIN PANEL _ — ( ) 2 v N 60A AC COMBINER -i N (INSIDE) I I PANEL BOX (OUTSIDE) W i M i I F— I I NEW JUNCTION BOX i l FOR ENVOY EXISTING 200A UTILITY—/ I I I I I I I COMM � z METER 240V NEMA-3RI I �I� jiI (OUTSIDE) I I FEE NEW 60A AC DISCONNECT m o I — — — 240V NEMA-3R (INSIDE) W o GROUND LEVEL f 0'-0" $ OUTSIDE ELECTRICAL ELEVATION DETAIL SEG CALE.NTS SERVICE INFO INVERTER SPECS MODULE SPECS WIRE OCP FOR WIRES ASHRAE AMBIENT TEMPERATURE SPECS MAX VOLTAGE IWERTER:M-215-60-2LL-S22-IG CONNECTED TO High DISTANCE EXTREME (VOLTAGE x 690 7-MAX VOLTAGE) UTILITY OOMPANY: MSP VOLTAGE: MODULE TYPE: QTY: WATTAGE• FRAME COLOR: A P ABOVE ROOF NEC PSEG LONG ISLAND 120/240 QTY: BREAKERS TO BE ° MAX UJ m g / TSM-PD05 08-265 21 265 BLACK 2/o Avg. 0.5" MIN VOLTS 6907 VOLTS 2` MSP LOC: SERV.TYPE: MSP GROUND: VOLTAGE: WATTAGE: CEC EFF' GREATER THAN THE o o ° 383 x 116 = 44428 W$ 3 Voc:38.3 Isc:9.1 Imp:8.61 Vpmax:30.8 SIZE OF THE BREAKER. 31 C 53 C 14 C c�# WEST OVERHEAD (E)ROD 120/240 215 96.5% nOES NOT PERTAIN TO SGLAREnGS' f 8a EQUIPMENT TERMINALS ARE RATED AT 75'C. STRING AMPERAGE NOT TO EXCEED THE 75'C RATING OF THE WIRE THAT IS ATTACHED TO THE TERMINALS. 3IM=3 M TD 1 40VV (E)200A TOP FED 60A _ _ C) UTILITY SERVICE MAIN SERVICE PANEL AC DISCONNECT 60A ENPHASE SOLAR ONLY s 240V NEMA-3R U W - Edr/25A FUSES LOAD CENTER NEMA-3R -S Enphose Envoy W=€ " 20DA/2P e m � � { "• o z'va�'z�� � � J CELLULAR REVENUE GRADE PASS THROUGH 1 Branch •" _ �'y� � (/�I I I 600V NEMA-4% -i a I I PRODUCTION METERING Of 11. I I FACTORY INSTALJ.ED 2 1 MWAM c710uIDED I I �� u, wm IJ- u cz t O J •l y>�'� o i I I 20A/2P N EN \ / r.=-,�-%' 'd W. / `, � r_-_ s u uj z I I G \\\\V\\\�� yO ��fW`�n Q:rn I I i q, 0 oo(n ---- 1 Branch `\S ``jr.W o"'a Z N Of 10. �__ _ "�o o n� (�CROUM 7 Momus MORM20A/2P mx urc oOa w WIx 0) OO EG co RCD 20A/2P F- F LU NOT USED O 0_ a LI U N U MODEL #: XAM1-120 3 CELLMODEM-01 Conduit Terminal Wire Temp. Wire Temp. fill Derated 75deg Inverter NEC Design Ground Ground wire g o Wire tag Conduit qty Wire gauge Wire type rating amp. derate derate Ampacity rating qty NOC correction Current Size type $ a $ 1 Open Air 3 B AWG 12 Trunk Cable 90deg C 30 0.76 1 22.8 20 11 0.9 1.25 12.375 #12 Trunk Cable 2 1"EMT or PVC 3 CAWG10 THWN-2 90deg C 40 0.76 0.8 24.32 30 11 0.9 1.25 12.375 #10 THWN-2 €t u o 3 Open Air 3 B AWG 12 1 Trunk Cable 90 deg C 1 30 0.76 1 1 22.8 1 20 1 10 0.9 1.25 11.25 #12 1 Trunk Cable Q 4 I"EMT or PVC 3 CAWG10 THWN-2 90degC 40 0.76 Li, 24.32 30 10 0.9 1.25 11.25 #10 THWN-2 5 1"EMT or PVC 3 CAWG10 THWN-2 90degC 40 096 38.4 30 21 0.9 1.25 23.6 #10 THWN-2 �� 6 1"EMT or PVC 3 E AWG 06 THWN-2 90 deg C 75 0.96 1 72 65 21 0.9 1.25 23.625 #8 THWN-2 ELECTRICAL NOTES: W h ga 1) All modules will be grounded in accordance with code , a and the manufacturer's installation instructions. 2) All pv equipment shall be listed by a recognized tested J "� lab. 3) Notify serving utility before activation of pv system. 4) When a backfed breaker is the method of utility ;b interconnection,breaker shall not read line and load. �i�-',i 30 , K5) When a backfed breaker is the method of utility l'r 101 p interconnection,the breaker shall be installed at the j�,_.� o opposite end of the bus bar of the Main Breaker. \"FYI �� z €�- 6) Work clearances around electrical equipment will be F�� '� + L=_ c z m a maintained per NEC 110.26(a)(1),110.26(a)(2)& 110.26(a)(3) co 7) All exterior conduits,fittings and boxes shall be �- yz / o rain-tight and approved for use in wet locations per NEC �> > �_; `(T y C -U�✓W \ 314.15. 8) All metallic raceways and equipment shall be bonded �, '' d O Y LL U oQ j and electrically continuous. LU 9) All pv equipment,systems and all associated wiring and interconnections shall be installed by Qualified Persons. W w o o 10) The photovoltaic system conductors shall be identified Z 'P W w and grouped.The means of identification shall be permitted �' ~x,o by separated color coding,marking tape,tagging or other & ocliLD co approved means.NEC 690.4(b) 11)Adequate spacing must be maintained between any F plumbing sewer vents extending through the roof and the underside of the photovoltaic panels(6"minimum recommended). ° 12)Pv equipment,systems and all associated wiring and interconnections shall only be installed by qualified persons (nec 690.4 e). S 13)Photovoltaic system conductors shall be identified and grouped.the means of identification shall be permitted separate color coding,marking tape,tagging or other approved means.(nec 690.4b) 14)Externally operated knife blade type ac disconnect switch o which is lockable in the open position and"on"and"off'visible m a designations which is directly accessible to riverside utility department employees at all times 60amp,250vac utility g lockable(ac)disconnect(nem 6.3 and nec 690.17)(nema 3r) 15)Photovoltaic meter socket will be provided within 10'to a 72'(center to center of meters)from the existing service meter and that it will be installed between 48"to 75"above the floor or grade level. E8 J - CAUTION SOLAR ELECTRIC SYSTEM CONNECTED PHOTOVOLTAIC DISCONNECT w N FOR UTILITY OPERATIONS W LABEL FOR MAIN SERVICE CAUTION , i •{ �{ 4 � m 3 LABEL FOR AC DISCONNECT �,4,3 70 -5 POWER TO THIS BUILDING IS ALSO J � 8 PHOTOVOLTAIC POWER SOURCE WARNING! { THIS SERVICE ALSO SERVED SUPPLIED FROM THE FOLLOWING' OPERATING AC VOLTAGE: 240 V BY A PHOTOVOLTAIC SYSTEM T MAXIMUM OPERATING AC OUTPUT .r ,T= ;�0 ' . LABEL FOR MAIN SERVICE PANEL SOURCES WITH DISCONNECTSC ' � CURRENT: 21 AMPS LOCATED AS SHOWN: ;� �l+'Ay'g ,�� �ujI�gJ�w LABEL FOR MAIN SERVICE PANEL COVER /� {',• 0 > WARNING! PHOTOVOLTAIC ARRAY ELECTRIC SHOCK HAZARD. ; ����t -- ' a°C m "r i o sly, ,s o\ AC DISCONNECT DO NOT TOUCH TERMINALS. o OPERATING CURRENT: 21 A TERMINALS ON BOTH THE LINE AND i W Y ; '� ' ` ra u� OPERATING VOLTAGE: 240 V LOAD SIDES MAY BE ENERGIZED U - s�, `3 0!, L IN THE OPEN POSITION. `� g ) - p C / LABEL FOR AC DISCONNECT LABEL FOR COMBINER BOX o `• Ly`' o�'W, WARNING! U oZF ELECTRIC SHOCK HAZARD. �a — W' n DO NOT TOUCH TERMINALS. CAUTION (N)SOLAR ARRAY � I �,g c F TERMINALS ON BOTH THE LINE AND THIS PANEL HAS SOLAR&UTILITY SERVICE POINT `z= LOAD SIDES MAY BE ENERGIZED POWER. UTILITY METERING © w c w~ IN THE OPEN POSITION. ALWAYS SHUT OFF BOTH BEFORE 0 6 Lu¢ S m W LABEL FOR AC DISCONNECT SERVICING. (N)AC COMBINER $ 00 LABEL AT THE MAIN SERVICE PANEL BOX a p 04 WARNING! (N)AC DISCONNECT N � ELECTRIC SHOCK HAZARD. w IF A GROUND FAULT IS INDICATED, SOLAR PRODUCTION METER AIN o NORMALLY GROUNDED CONDUCTORS LABEL AT PRODUCTION METER a MAY BE UNGROUNDED AND ENERGIZED LABELFORINVERTER WARNING PHOTOVOLTAIC POWER SOURCE S U CAUTION:SOLAR CIRCUIT DISCONNECT PLACARD RIVITED TO THE MAIN SERVICE PANEL WARNING LABEL SHALL BE PLACED ON INTERIOR AND LABEL FOR AC DISCONNECT EXTERIOR DC CONDUIT,RACEWAYS,ENCLOSURES,CABLE ASSEMBLIES,JUNCTION BOXES,AND DISCONNECTS.MARKING SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS,ENCLOSURES AND CABLE ASSEMBLIES EVERY 10 FEET(3048 MM),1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING cp ASSEMBLIES,WALLS OR BARRIERS MARKING-PV CIRCUIT it r i; $ d n MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR PV MARKING CONTENT AND FORMAT CONDUIT,RACEWAYS,ENCLOSURES,CABLE ASSEMBLIES,AND MARKING CONTENT CAUTION SOLAR f JUNCTION BOXES TO ALERT THE FIRE SERVICE TO AVOID CUTTING CIRCUIT THEM MARKING SHALL BE PLACED EVERY 10 FEET,AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS,AND AT ALL PV CMBINER -RED BACKGROUND 3 AND JUNCTION BOXES. -WHITE LETTERING -MINIMUM 3/8'LETTER HEIGHT „�,� REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE -ALL CAPITAL LETTERS ENVIRONMENT(DURABLE ADHESIVE MATERIALS MUST MEET THIS -ARIAL OR SIMILAR FONT,NON BOLD REQUIREMENT) W m'o W y � THE AL AX MODULE Mono MUM .solutlonx o!Om.,""., 03M RANat ."- r <F}FalearoF+C.Ii^EP•x+P.IC....AePPoIAD..mAa,Rk_AJFMne,0 IYJ Di4- -25511� F3eCr- 2yn!.!+`4ri l•_�-P`�_ `_??.0A_3 L _ :iS0_Sc,T._4_:.:'A_W 5__ t -••�:_-585 X� .., Z3R 05 - 2M1 7E LL al VIMEptxtOAx OrNMO .- N'evwmlb.-,n Gne+;f„'••li.I 0:0. ''{&2i^-: B5� r _Gd,- - _ I 7 MODULE, I�{' �1t�� ,e drmmPn 'O(»•+Ora.•Yoneac'rz:4'� M. _ &U n L4 lSm ®�®� +, - .'io-fLr ' yr0� �` - 10 a W D U �� :aCWn[fl�c•+as rI;R4l ~� 11.3 4,' 14L lA>• V rd y>u� WZ ®mm .s.F,,. ...,:,.n, fi,° - r�rKalmrcn^rmnmesnrirre>nne:�t..fr,..n�r✓,ss W=m2abU ' Q st.enaeAFeuA(Notrl O Z m 3 9zr -- - � ��®� � x _---" - ^m.m,Mnr•�w:,`,:,P:; Iso- -Iso ._ �- sal , f = NIUCTiCWY TAILINEMODUIE,_ SI 6 1Ems! _ f;�_ _tw; _._sa v y3.;.,_ o_.,.,_ 'gglQ,wG L-+� „��j.10-' c•I.fy pb4 g_ _ yy)�-"gyp-yam /�/�pe�fYa���'r�t�'ry-•(`' - S , � _ „ •� inJ..rlvda,vt�ICUiW m'.Mi.a<'.arcnevwa di'.`,xiviP�rTF 9y41 V. L V V;■,YI'__• I _ ; _ MKMANItAl04W R.2 U p J € ,00 Our 1 `smc,a,e: - n+wr�R:unols-rnmrnxK+t - LU Z tno a - - 1 Our most versatile product cc—of c_-in os sa,_,ZC6 x,.pm.,- : _:ns r ogs y L c _ `.heuke Jvrs� It50i x:•35mmfc,aSx5595x 13%^cnl N a U O aG f j ...- =-,..;�_._.,,>_ _,_.Y = w o �Z -- :' /O, „,-" _ �leawMr-Ial.s„r „i+.cnr•-r.-o;x:a.�F�Paa•emrKmac>ta,'.i o r w F-� �TAA dMUM'EfF,ICIENG_Y. - 'y - _ raa�r':,_oi� 'moi` "ssesalo,♦c�oo_s.^5i„- ",..`a ,, A w o Z o 1`w2'w SS 14' 'F'ar+F^ ` .blxf}SGP-a AIrF,fMtMm W=W One of the Industry's most trusted modules_ �,,..,�..,rt g O o O f -_ _ •Fle.'.o�:`v+nfrrrsf;vrr_,. ,Ca01n: � rFv!7�laar¢c•hl_"PrcaSlozerrri,bme.*:r,es4rf� - a J •- F� :i0°, o a� r; a o f POSRIVE,POWERTOLERANCE.i 3 a •t >,yx�- ul f Highly reliable due to stringent quality control J - _,X':.3 h�G I,t9 Rio7rjj:+N`J7 •j'hy, •Lr�rc?•;y'rnr, h;.`G'i{IUY'�t;(„^„^.�rYrC^�t":Jv!'; - - {NGURV25O(IJMODUlC 12�a'1' rFMRE8M1i1RClAr NGS MA¢IMUMRA11N6E O �N rUv;•y>ttY+iO tx�- ,"CJ 'r,h^�Il.0 tas�IrC i=-4lr.v:.;E.M.”.:r?v+v'I;.-'C.f„n't�N'C(!'^'Yr5 u' - - -- I.on ` _ _ - ”. _ Q' 'W^:::l,rft9,li-19M;',15�GUh:^' - IDUI,•5,'li1. .M ceryl CPt'q I,:�Ceh QaC lne�. Cp'-"+a-:I Ron Fc.alWo;�0_,8."'C,� a �' lrn L•'•tIC... '� MGv'rr2nCSf UCP`•r, i�/P'_fr�y Yr" i,^'y`:f.'•�1V5('r ry�rr+M1�f Clw`f�;i, - 11af1Vad ,i VtCS,IFC=eAUPliu Z'. --y�.-„il•p,.re,aKz a,;>.;:^at r _ ---- 1., Y,r !A'yoC'�>;'7 = r._�•;ecr -.xl x:i+:�r`v,�.:f, inrvlxrof,.+F ezfebYr_ : ,os_^c,'c, _ .s trr_¢a,_a�It isA'_ r ,:LIG:'>SY._.`N ror:cff+r G._'C'.in• I �J , tlue,Pefev�VCsta.�.�,�n=C!_•�'..:%,ODS%�-;J --- - r`•e,,:',a-' ".';r,-an:r-m?r+,u, - Certified to withstand challenging environmental conditions '✓'.1'a"'� ;;St%rY;.Yom, _4�,AlfC IxO - WA92AP41Y 7 :,#,nr:"}�',' vs.« - 4�6Ja:smO'rix/J _ _ 'la,ca:Pnm_amr P,;�•m-f. z ' Y^w.t•Cr:'Y,-:F-�T^+:' _ _ - ••wvv - Sves nn^o an�e�W.r a^ I ”! e �jy`y,u-,c,.�,v'r::nu:� - ,. - _ rE,nwsn,,.r•.....-....._.6.,.._'>or,u -_.... i� '-a3Ye'S`O,a+�rJtwh:v,nl%�„�,`tt,:i v _ _ -_ - _ _ - - .. _- ,H�.a„a,.c• v.r - �x Tti5*I'l:A3i:r'E•A'ti�„�'.. �GFnIfICAROV”" ; :."LINEAR'PERFO'R(6flANCE,WARRANTY,: CE .� RAt.A NGGan°earA:,e`: --�.•-= "-l8 yearProductWorra+sy•'e5'taorLEmar PowerWGFfCWY - "� I � _ �,--".:•r.�-rcM `- - - "�' dao- - - - °� '•—_ _ � � o _ ,. •- _ rn' ", - =--- °tu'faar.vn�r •_ .14^i.,.Fnw rFr uur_�f nrRencl..nua,>,e.h,_:n>.�a,v o ( • r` �y �HG'"':':.', o�Jb'nvv>tmum•r,.wna^'.r-c7 Jr`rm��..+.°runea n.,.=a-er._•aea4w.maxlw...fm„r,.n- m m`' Irsalar: 3o t.' `�� sofar Smm:Fn wTo vhd E10 W N s = & Enphase®M215Micromverter//DATA $8 a Enphase°Microinverters INPUT DATA(DC) M215-60-2LL-S22/S23 and M215-60-2LL-S22-NA/S23-NA(Ontano) Recommended mput power(STC)r 190-_27 W _ - - _ - Z Enphase®1111215 Maximum mput DC voltage _ _._ __--, -45 Vr ry^ _.^ _T_ a a0 S Peak Power,trackngyoltage ,' 22-36y_ I QQp o Operating range 16-36V Y to m v u 22 V/_45 V_ Max DC short circuit current _ 15A W__€ -m L) input Current �' "Y1OS A - _ '� _ - ._ _ - _ c Q� ozS OUTPUT DATA(AC) 0208 YAC ®240 VAC J_ Rated(contmgous)output powers 215 W -- 215 W" - Nominal output current 10 A(Arms at nominal duration) T 0 9 A(Arms at nominal duration) 208 -�j Extended voltage/range 179-232 V 206.269 V _NommaPfrequenoy/range4 6_0 0/59 3-6.0 S Hz - - ;60 0`/59 3-60 5 Hz o m W I en Kase Extended frequency range lT'57-605Hz - / ^ 57-605 Hz _ _ W Z o ? 1I 11 tri -__-_ -____. _ r_ _ _ � L�d�-E N E R' G Y- Power factor- _>095_-�.- >095 . - N�W a n�� LU Maximum units Per 20 A branch circuit 25(three phase)• -y_ M-- 17(single phase) - y u��'(1) _ -,Maximum output fault current �e �e -1,05 Arms,wer 3 cycles,1 04 fvms over 5 cycles _ r m a LU o o Z �iIX o^ .- EFFICIENCY _ u�i S z to i WWW'z CEO weighted efficiency __ ,. - - 960% w� -3 o � Peak inverter efficiency 963% 0 0 0 .0 0 Dynamic MPPT efficiency(fast irradiatlon changes,reference EN50530) 99 3% _______.__e.�._ _ _ ___._._.- .-r_.-____ .__�___...._ The Enphase'Microinverter System Improves energy harvest,Increases reliability,and dramatically Night time power consumption _ _ 46 in U W simplifies design,installation,and management of solar power systems. MECHANICAL DATA o The Enphase System includes the mlcrolnverter,the Envoy'Communications Gateway"and Amment temperature range -40°0 to+65°c •° - ^ a Enlighten,Enphase's monitoring and analysis software. operating temperature range(Internal) -4000 to+as°c Dimensions(WxHxD)_ _ _ 173 cm x 16 4 an x 2 5 cm(6 8"x 6 45"x 1 0")without mounting bracket Weight 1 6 kg(3 5 lbs) PRODUCTIVE SMART Coop"g _+__.. _-- Naturalconv__gn;Nofa_n_s_Y - _ z Maximum energy production Quick and simple design,installation, Enclosure environmental rating Outdoor-NEMA 6 N -Resilient to dust,debris and shading and management FEATURES -Performance monitoring -24/7 monitoring and analysis Gompahbiitty Pairs with most 60-cell PV modules RELIABLE SAFE Communication^:- --Power fne- -System availability greater than 99 8% -Low-voltage DC Monitoring _ Free lifetime monitoring via Enlighten software - -No single point of system failure -Reduced fire risk "�_Compliance - -, --• f _ '--- ".UL1747/IEEE1547,f=CC Part 15 Class 9"" _ - - •- CAN/CSA-C22 2 NO-0-M91,0 4-04^and 1071-01. o 0 _ __ _ ._ _ _.__ __ r � f � enphase° c To learn more about Enphase Microinverter technology, f�l enphase° LL JJ E N E R G Y us 02013 Enph-Ene MrvhIs reword MLa4emaitfl orbards n UI dx:w era repswed bithert ssped,a L $ 51¢ETMIY®HL Ell ^ 1 ft W f'no .,; '_ :, k .,1,; GreenFasten"GF1 -Product Guide Exploded Product View,Bill of Materials W i f Materials Needed for Assembly Z 3 "'' - - Item No. Description of Material/Part Quantity �pW Z.LU o $ 1 GF-1 Flashing 1 o w x o ';}:";,;'; Y. 4 i• 2 L-102-3"Bracket*(other options available) 1 a 0 F 5w T' ` 3 5/16"EPDM Bonded 304-18.8 SS Washer 1 c z a$ 4 Lag Bolt 5/16" 1 Required Toolshaw °ai p8p `i V'f'#, 'I�✓�(y i}+rva-.��>'.Y_ .;;t;"�i' `'° (1 w o Of Z ^it W FF 4. r fPo = AM o Je, .'} m m F 877-859-3947 Committed to the Support of Renewable Energy o EcoFasten Solar'All content protected undercopynght.All rights reserved 10/17/13 1 1 s� ffi SOLAR N E AN ENiE TS 10 \' RAC I r q .., :s;;` a:;;, 1 © v v FW HH C N i man U I�I RAC = t. h:', su F' 11(1If A J a = _ .<< z+fffiW, ;:„ i`,. ::4 k % 1, X14 . J8� �8 ;k.. _ }� AHILTI GROUPCOMPANY _ I _ -, - - Q` ''�� p `,�-'�3's�,.;e'._ _ _ • - m$ 'm> mouff SOLARMOUNT defined the standard In solar racking New enhancements are designed "~ t -- = Z to get installers off the roof faster than ever before.Components are pre-assembled p;; ; ,+ j x r `; `; _ - Kt- 9 , 3` W 5 and optimized to reduce installation steps and save labor time Our new grounding & _', C tn' to Sx -'=— sz ita f, '4 �N_� F� $ bondingprocess eliminates copper wire and grounding straps to reduce costs.Utilize osiE z ' 1 " °.r P PP 9 9 P - ` '3a2{b�aPsc1(1. " ' syr�r= 1Q,�: the microinverter mount with a wire management clipforah easier installation. RIX•', '' ;}` o€rtes Z ELIMINATE THE GROUNOWIRE FROM YOUR SURMOUNT ARRAY - �°`•^^-__ �> = � �� o LOSE THE COPPER &LUGS -GROUNDING 1[e]ehpha INTEGRATED = � j E E R G Y W mt r mrza r i yt9 i P QnCiA uT3 ©, w Wv W m a �;6;'W W o o ff• tm '" _ w _ _-gc .' �.tc`+'z-�_R�-'_'-z,�:y r.,' - - _ F.w �'a"...V_•-r3Y4• CPrir - - .¢r3 _- - - i✓'�� _ - _ - _ - - W t W o cn 'Z Z, _F4 YC !rt7.E717L: k1S�i14KTS0F1Mi3Sis;4 u ° ''/ - _ �i'.Q� rc0 co �3 LC SL79m 4Pi4 G215bt-Olaf 7gJtl b ------- W — o j`8 Y e 6-7 ,_, �� :_F.. .• ..,;,::.. -„�' _-. _..;�-„=..�'_,'_” IN `.. _,. MOW --- L SEW OFF- E �r � 1 = o > .................................................................. .......................... ....... o yN to a ' VERSATILITY AVAILABILITY DESIGN TOOLS OPTIMIZED COMPONENTS - I ,. I ���Ila.UlL'1!.EILilU I r I_ I �Ul'1WY,uUu•?��4".utt�'Cw'Lvw�3cw�tS� - � !E E13 ar W LU is 3Z `o g`gx e8 8 Enphuse AC Combiner Box//DATA Enphase A:Ccmbinei Box MODEL NUMBER' Z AC t:ombinar Box.Metered AC rnmbmar wnh EnphreF Fm ay-S MetareC for rnlagmtad reGenue grade PV pioducaon G w Enphase AC Combiner B®x ACCESSORIES metenngfANSICI2 0r/-05N pandNg)andoPtionaconapmpbonmonitpdng(+h2546)+ U. ACCESSORIES(CrdAf Sop3rateiyj �O -Enphnsp`Mebile Connect Hug cnd playvnduoUal grndrt+wiU''<diular gadeWe_yeor dale planforsyaiensupto/2,: �yf CElLAGOBd-U7 _ kW,(Avmlable in the US.Comedo,M.A.Puerto Rco antl the US We.tloMs,where e. _, _ - __ _- there is adequote cettular sornceln U--nstolla6on5rea)m� " ,__ ,�Y I J C 1,��•r. ,„.�.,_;�- - _ eµ” ^' ,,,>7 Consumption Monitaring CT Spbtwre current transformers enoblewholehome eoncumplion matarhtg(+/-2,5.). Z l9€a�w CT-200-SPDT Q 12,2 iFa '+.i ELECTRICAL SPECIFICATIONS `•' e ' j = ^`�� �=> {+7 F „hlaxunw+i rystem size_, _ _"> _.�. ,_it bkW at 240 VAC..`-._,_....._� v_.._�...-"_._,.� __ •_ ._:�-._-� Rating _- ConMuous duly { 4fy�`� ': i•:��-,%a 1Maxlmum system volla9e' ,. ... ,..,-.,n 'OU VAC ,. _,-._ -.....j,; __, _.__ ,.. _._ ....___..,_,_._.. , Rated output current - J 46A _ �:-•, i,tf;-, _ _ _ - _ „- - Road input cunen4 each input ___-." 18-A..:w_. ._=._.._._ ......_ _. _._ _- _ _ O Uj Maxidlum fuse/cmiak breaker rating(oulpu0-. 60A__ f,µ __•,-, ._.w I LL(� o Z orb .1 breoke,a _ ,Three 2-pola 20A/240 VAC OIN roil•mounted breakers_, �;, _ _ :i io w z p .A u nMetenn T Wak-dcore-re-mstal.d on solar b-bar andtnred to Envo-S �W r W ...... :.-{ 3 .y Prod cho 9C P - y y uS"�❑ o W.r- Y,l<:�31 ,,.� • ;N..8 -.S,S,_ -MECHANICAL DATA a W to o 3:} .,FFF"""✓FIr.�t•-. e hf"�-;`�,,I .iiaa�eu O ' - 060x387%205em(150'x 159-x80'I' wo Qe OZ OmanionstWxHs _ Waght 5.1 kg(1121bs) to y rl ':' ' ,�= t' �.'T-'-� =,'}r�'q� ''�f:, -Ambient temperature r4ngas •40'Cto.46'C(•40_10115'Fj j _ _. _____ y_i w g a =2 (•.' _ •{" i - - :' t,1 I Cooling. „ _ .._ _ _Vented,natural convecbon _._ - _ - ___ _ S o N ": ,IT,.1 ,a;, „, Enclosure enmonmentN mnngn-; Cotdoor,NRTLrearblietl,NEAAAtype 5R_polycarbonate cronatrudlon a0 Wirssize 70AWGforbranehulputs 4 AWG for combined output(3 cucwts) F Jt _-, •_ - " - _ � f i - _ _ _ _ - _ 6 AWG for combined output(2­Wit) M -_ _ _ _ _ V AltitudeV - `- =To 2000 meters(6,560 feel} - - r uj INTERNET CONNECTION OPTIONS Y K intogmted Wi-H'" _ ,, r;p2.11b/g!n' _ 7, a Ethernet 902.3 Cat6E(cr Cat 6)UrP Elhemel cobla(mol included) The Enphase'AC Co Titriner Boz with Envo -S consolidates Interconnectionequipment Into a sin le _.. ..,.__. _--: y g CeVulo . OpbcnN.CELLAAODEM Ol jnot mGuded • - enclosure and streamlines PV Installations by providing a consistent,pre-wired solution for residential COMPLIANCE $ o applications. CompllanceyCoin'er cox' _ _ UL1741 - _ Compliance Envoy-S UL916 CAWCSAC222No 610104 SMART SIMPLE RELIABLE 47 CFR.Pa r15,Class B,ICE5003 IEGfEN 6101x12010 ' -Intrudes Envoy-S"fer communication Three pr6-instellej 20 A/240 VAC -Durable NRTL-cErtlfied NEMA type EN50065•1 EN61000-4-5 EN61000-6-1;EN61000-6-2 Metering ANSI C12.20 accuracy class 0 5(Pandmg) and contrd circuli breakers 3R enclosure Flewble networking supports WI-FI, -Pre-configured reve15ue-grade -FMe-yearwarranty Ethernet,cr cellular metering available y � o a 3 enr( hale- To learn more about Enphase Microlnverter technology, ( p enphase- ~ E N E R G•Y LISTED visit enphuise.com L �E N E R G Y P!t!.GKI'a;e�'-'ia'•d-3 a'vca A:m�dxuM:�Sran.'kFRs d'.y,mmeafe mpszaN C/e'J rt's:nws_emv. VAT MIl-0 p `� SNEErmINBFA. E14 Qd W 'ao LU 3� Enphase Envoy-S//DATA, m_ MODEL NUMBERS 3 w:38 Enphase Envoy-S - - •) Enphase EnvayS Stnndardr• _ - Enphase Envoy-S cammuniphans gateway wi0tbasie PV prhtluehon momlpnng(+-/-5Y)' ENVS-AB-120-A` Enphase Env®y�S Series y ENV,S-AEnvoys Metered* ^L ~ Enphase(ANSIEnvoyS 2,20 W-06%)a d option limneumptIed revenue grade P.6%)production LL o ENVS-AMI-120 metering(ANSI C13,20+/-O6%)ond optional hencumpRan momtonnD(«/-26%}. = r�Q p ACCESSORIES(Order Soowatey) I COO.8 Enphase Moble Co_nneetn - -_Plug and play industrial grade-9.1 r modem with frva-yesr data p)on ler systems up(o � W CELLMODEM-01 60 miceinvertxs(Avsrf ble In the US,Canada,Mawco Warto Rrco`and)ha,US Virgin' j O ro ;r_t;»- «- - -_ -`_ -; - ,"_ -- ,Islands,wherethere is cdequate cellula servieein the_ ___hon area} y_ -,- `„ yl= 2r W r Consumptmn Momtonng CT For usewith ENV-S-AMI-120,spGheomcurrenlfranefermemenabtewhdehomeeonsump- ZO�min as plRd�_°'.y CT-200-SPL)T twnmetenng(+/-2644). O Z 3$2 11 POWER REQUIREMENTS Cord_conneeled - 120 VAC,60 Hc(ENV-S-AB-120-A) - - • - _ _ -._ Y __,._- Max•15Aovercurrentprotecllonrequire -' Hardwuad4_ 120 VAC 60 H-,(ENV-S-AB-12Dd) 1?Or240 VAC spht-Phase(ENV-S-AMt-l2iJ1 .y ,�.'wY•._�Y, - _ Max lSA overcurrent proteotlon requimd CAPACITY p LU ct_tmcreu_rv_erfere Palled UP to 60DY z O J W V•�WW ` MECHANICAL DATA _ q p Q�j W "Dimensions(WkHx0)•-�, - y ,, �� 21 r3 ii•126x46 crri(8~4'x6",z18� _ w = T 8 U) Q} Z „Weight - 17.60.:(498 til o W F uPmbtent iempera0tre range - _.-._ -40'.to 65°'C(-40'to 149° ---r - `_ - .Z W r W Z 46°C(T40Ia'15,F)d T-salledfo an endosure - msQ c 2'W 6fvuonmentdrating _ IP30 rror mslallahon_md_oors or in an NRTL-aertded,NEMA type 3R enclosure.- 4 4 g q O o 0 to To 2000 meters(0660 feetlr - _ _- -- - - - m]�J r, to INTERNET CONNECTION OPTIONS Q :InfogrAted Wi=Fr - 8o211b/gM The Enphase Envoy-S!'communications gateway delivers solar production and energy consumption data - — -- - <- l_ of to Enphase Enhghtenrw monitoring and analysis software for comprehensive,remote maintenance and Ethernet _ 8023.DafSE(or Cnt 6)UTP Elhemet cable(not mduded)' 4 W "Cequlor T - AOptional CELLLWDEM-01(-I induded) management of the Enphase Mlcroinverter System. COMPLIANCE d ?' Compliance UL918 "'- '•} 4,;'' .' -, With revenue grade production metering and consumption monitoring options,Envoy-S Is the platform for CAN/CSAC222No sioio-1': ' total energymanagement and integrates with the Enphase AC Batte r 47CFRPan.'12010 e;)cEsoo3 9 9 P ry tEcrENslalo=Roto EN50065-1;EN610o0:4-5 EN61000.6-1,EN81000-6-2 y . Metering:ANSI C1220 abcuraryclaos06(ENV-SAM1-120) z SMART SIMPLE RELIABLE Enables web-based monitoring -Easy system'ccnfiguration using -Designed for_Installation indoors and control Installer Toollot mobile app or outdoors -5drecDcnal communications for -Flexible netwcTking.voth WI-F, -Five-year warranty remota upgrade Ethernet,or cellular r' R o UL w f l enn�a�e° To learn more about Enphase Mlcroinverter technology, enphaSe- o ~ E N E R G Y LISTED visit enphase.Qom � �E N E R G Y .201aeums=6,ergv<nri�nrs merwv Mumu cxbra Y3mrb 0cenv¢ao.sasraea by s7er ror_cxw avts.. t2n va;l5 3 sr�rauuma E15