Loading...
HomeMy WebLinkAbout41127-Z ��o�gUFFat�Co�� Town of Southold 1/30/2017 o - P.O.Box 1179 a' 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38802 Date: 1/30/2017 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 65 Garden Ct, Southold SCTM#: 473889 Sec/Block/Lot: 63.-7-17.10 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/20/2016 pursuant to which Building Permit No. 41127 dated 10/31/2016 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Cochran,Robert&Helen of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 41127 01-17-2017 PLUMBERS CERTIFICATION DATED Authorized Signature TOWN OF SOUTHOLD ,�o� ffQl�coay BUILDING DEPARTMENT y TOWN CLERK'S OFFICE o,, • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41127 Date: 10/31/2016 Permission is hereby granted to: Cochran, Robert & Helen 65 Garden Ct PO BOX 1623 Southold, NY 11971 To: install roof mounted solar panels as applied for. At premises located at: 65 Garden Ct, Southold SCTM # 473889 Sec/Block/Lot# 63.-7-17.10 Pursuant to application dated 10/20/2016 and approved by the Building Inspector. To expire on 5/2/2018. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALT TION TO ELLING $50.00 Total: $200.00 134din Inspector V Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses, or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 " Date. d V! New Construction: Old or Pre-existing Building: 1� (check one) Location of Property: (0-5 61AM Colin l ffik 1dd House No. I- Street Hamlet Owner or Owners of Property: �,Y1c�—���,hfox-\ Suffolk County Tax Map No 1000, Section Block Lot Subdivision Filed Map. Lot: Permit No. qj( �q Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ 4,0� A k\j;� Applic 4t Signature oF so�ryQl � o Town Hall Annex Telephone(631)765-1802 54375 Main Road N Fax(631)765-9502 P.O.Box 1179 G �� roger.riche rt(�D_town.southold.ny.us Southold,NY 11971-0959- �Q �yCOUNT`I,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Cochran Address: 65'Garden Court City: Southold St: New York Zip: 11971 Building Permit#: 41127 Section: 63 Block: 7 Lot: 17.10 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Solar City License No: 51331-ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock EJ Exit Fixtures TVSS Other Equipment: 6,375 KW Roof Mounted Photovoltaic System to Include; 25- CSLP - 255 Panels, 1= SE 6000 Inverter. Notes: - Inspector Signature: Date: January 17, 2017 0-Cert Electrical Compliance Form SOUlyolo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ] ELECTRICAL (FINAL) REMARKS: DATE I 17 INSPECTOR Version#66.3 PIL ,",",, 'SolarClt 0, Project/Job# 1191390 RE: Installation Approval Letter Project: Cochran Residence 65 Garden Ct Southold, NY 11971 Date of Review 3/27/2017 Permit# 41127 Date of Install 12/30/2016 AH] Southold Town SC Office Long Island To Whom It May Concern, On the above referenced project,the roof structural framing has been reviewed for additional loading due to the installation of the solar PV addition to the roof.The structural review, including the plans and calculations only apply to the section of roof that is directly supporting the solar PV system and its supporting elements. The capacity of the structural roof framing directly supporting the additional gravity loading due to the solar panel supports and modules had been reviewed and determined to be in accordance with the requirements of the 2016 NY State Uniform Building Code, ASCE 7-10,and 2012 NDS. I certify that the work has been completed in accordance of the provisions of the approved permits of the applicable code. Should you have any further questions or requirements pertaining to this project, please do not hesitate to contact me. S Paul Zacher, P.E. o� NE- Professional EProfessional Engineer K. Zq C 0 T: 916.961.3960 x101 " email: paul@pzse.com fI ce a .o136 . 2 r I � N G. � � FIELD INSPECTION REPORT I DATE COMMENTS . b FOUNDATION(1ST) y ------------------------------------ `� C FOUNDATION(2ND) z �o ROUGH FRAMING& PLUMBINGy INSULATION PER N.Y-. ` 7 STATE ENERGY CODE _ FINAL C) ADDITIONAL COMMENTS O 0 p ® Z ® m O � o x TOWN QF SO3UTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 o Planning Board approval FAX: (631) 765-9502 Suryey SoutholdTown.NorthFork.net PERMIT NO. 1� Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined r 20 Single&Separate Storm-Water Assessment Form Contact: Approved 20 Mail to: SolarCity-Anais Fernandez Disapproved a/c 923C Motor Parkway Hauppauge,NY 11778 Phone: 631-355-5125 Expiration ,20-1— Bui ing Inspe for D OCT 2 � 2��� APPLICATION FOR BUILD G PERMIT te� ��, , 20 1 (9 1;uUMING1)Wr- INSTRUCTIONS P °�Som® D app kation MUST be completely filled in by typewriter or in ink and submitted to the Buil Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signatre of a icant or n1—,iT-a corporation) 923C Mot P ay Hauppauge,NY 11788 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Contractor/Agent Name of owner of premises y� CQ cy)rckn (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. 52057-H Plumbers License No. Electricians License No. 51331-ME Other Trade's License No. 1. Location of land on which prop sed work will be done: fir - !�o1 G l\( House Number Street -Hamlet- County Tax Map No. 1000 Section Block V ,;,Lot r t r, r• .. i Subdivision Filed Map No. Lot •, • , .. 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Residential b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work Krw VY1Q�1t �11�C / (Description) 4. Estimated Cost- �'I Gioa Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Depth Height Number of Stbries 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth "` - e - •<3 " ' lire, r 10.Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12.Does proposed construction violate any zoning law, ordinance or regulation?YES NO 13. Will lot be re-graded? YES NO CoWill excess fill be removed from premises?YES NO CiY- 14.Names of Owner of remises 4 �CCh►'?^i�'1 Address 65�1Gt��WC*&MidPhone No. Name of Architect 6n,1 Address?x)55 G�arJlcwwuLl Phone No (06�)- L8 -1096 Name of Contractor SolarCity Address 923C Motor Park ay Phone No. 631-355-5125 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF� being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contractor/Agent (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Swom,t,o before me this da of OCtDbr-Y- 20j�p f 1E PERM YP YORK Not Publl�gistration No.01PE6328470 S'gnature Qualified in Suffolk County Commission Expires August 3,20 o��aF SQUryo Town Hall Annex 41 Telephone(631)765-1802 54375 Main Roady (631)765 5 P_O.Box 1179 G Q rocier riche rtC.01(631) Southold,NY 11971-0959 r' wi11y 111 �v` BUIMING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: Company Name: Name: License No.: Address: Phone No.: JOBSITE INFORMATION: (*Indicates required information) *Name: CG(;kfQ,n *Address: *Cross Street: *Phone No.: Permit No.: Tax-Map District: 1000 Section: Block: Lot: *BRIEF DESCRIPTION OF WORK(Please Print Clearly) V e (Please Circle All Thai Apply) *Is job ready for inspection: S/ Rough In Final *Do-you need a Temp Certificate: CY3E / NO Temp Information Qf.needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82--Request for inspection Form Scott A. Russell ®�U � ST01kMWA\T]E]k SUPERVISOR MA\1N,,,A\(Gr]EM]E1N\7C' SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 ° ®� Town own of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT INVOLVE AW OF THE FOLLOWING. Yes No (CHECK ALL THAT APPLY) 09A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑ff C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. [][RI/D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑QBE. Site preparation within the one-hundred-year floodplain as depicted on FIRM Map of any watercourse. ❑[ /F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above,please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department wiff—your Building Permit Application. APPLICANT: (Property Owner,l?esI n Professional,Agent,Contractor,Other) S•C•T•M• #: 1000 Date- 1® District NAME 6's n(� kt 63 d� 11-240 / )�/` 4 Section Block Lot g'° �,,✓� _ i "°°** FOR BUILDING DEPARTMENT USE ONLY*"** Contact Information `l�J 1 J 1 � t Rekphorc Numbel Reviewed By: r� 6UfA6h_ - - - - - - - - - - - - - - - - - - Date: 10-%)d Property Address/Location of Construction Work: — — — — — — — — — — — — — — — — — U'Srr Approved for processing Building Permit. ���^��� � Y�y Stormwater Management Control Plan Not Required. AhG Stormwater Management Control Plan is Required (Forward to Engineering Department for Review.) FORM * SMCP-TOS MAY 2014 SolarCity D [�C�f�O `�C� DD January 5, 2017 JAN 6 2017 Town of Southold Building Department BUMDINGDEPT. P.O Box 1179 TOWN OF S®UMOLD Southold, NY 11971 RE: Permit#41127 I am submitting the updated plans since the panel count has increased from 24 panels to 25 panels. Address is: 65 Garden Ct, Southold, NY 11971 1 am the applicant Anais Fernandez with SolarCity Corp. My phone is 631-355-5125 or email afernandez1(a)-solarcity.com. Please advise if you have any questions. Best Regards, Anais Fernandez Permit Coordinator afernandez1 @solarcity.com 923C Motor Pkwy.,Hauppauge,NY 11788 T (888)SOL-CITY solarcity.com AL 05500.AR M-8937.AZ ROC 24377VROC 245450 CA CSLB 888104,CO EC8041.Cr HIC 06327701ELC 0125305,DC 410514000080/ECC902585,DE 208120386/Tt-6032.FL EC13006226.HI CT-29770.IL 15-0052 MA HIC 168572/ EL-1136MR.MD HIC 128948/11805,NC 30801-U NH 0347C/12523M.NJ NJHICN73VH06160600/34EB01732700,NM EE98-379590.NV NV20121135172/C2-0078648/82-0079719.OH EL 47707.OR CB180498/C562.PA HICPA077343,RI AC004714/Reg 3834,TXTECL27006.UT 8726950-5501,VA ELE2705153278,VF EM-05829,WA SOLARC'9190VSOLARC•905P7.Albany 439,Greene A-486.Nassau H2409710000.Putnam PC6041,Rockland H-11864-40-00-00.Suffolk 52051-H,Westchester WC-26088-H73,NYC 112001384-0CA SCENYC:NYC Licensed Electrlclan.#12610.#004485,155 Water St 6th FI.Unit 10.Brooklyn.NY 11201 7!2013966-0CA All loans provided by SolarCity Finance Company,LLC CA Finance Lenders License 6054796 SolarCity Finance Company.LLC Is licensed by the D daware State Bank Commissioner to engage In business In Delaware under license number 019422.MD Consumer Loan License 2241 NV Installment Loan License 11.71023/11-11024.Rhode Island Licensed Lender#2015310311,TX Redstered Creditor 1600050963-202404.VF Lender License#6766 CLE Workers' CERTIFICATE OF STATE Compensation Board NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1 a Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured (650)963-5100 SolarCity Corporation 3055 Clearview Way 1c.NYS Unemployment Insurance Employer Registration Number of San Mateo,CA 94402 Insured 49-892777 Work Location of Insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 02-0781046 2.Name and Address of Entity Requesting Proof of Coverage a 3a Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) American Zurich Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box 1 a" 54375 Main Rd,PO BOX 1179 WC 0182014-01 Southold,NY 11971 3c Policy effective period 09/01/2016 to 09/01/2017 3d The Proprietor,Partners or Executive Officers are ® Included.(Only check box if all partners/officers included) ❑ all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above In box"1 a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2'. Will the carrier notify the certificate holder within 10•days of a policy being cancelled for non-payment of premium or within 30 days if cancelled for any other reason or if the insured.is otherwise eliminated from the coverage indicated on this certificate prior to the end of the policy effective,period? ®YES ❑NO This certificate is issued as a matter of information only and confers no rights upon the certificate holder This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by. Gail Sydow (Print name of authorized representative or licensed agent of insurance camer) Approved by: 09/01/2016 (Signature) (Date) Title Vice President Telephone Number of authorized representative or licensed agent of insurance carrier (415)538-7109 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-15) www wcb.ny.gov DATE( YYYY) v�!R� CERTIFICATE OF LIABILITY INSURANCE o6/1a/2016/zols THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH RISK& INSURANCE SERVICES NAME: 345 CALIFORNIA STREET,SUITE 1300 PHONE FAX 'C. IC No CALIFORNIA LICENSE N0.0437153 E-MAIL SAN FRANCISCO,CA 94104 ADDRESS: Attn.Shannon Scott 415-743-8334 INSURERS AFFORDING COVERAGE NAIC# 998301-STND-GAWE-16-17 INSURER A•Zurich American Insurance Company 16535 INSURED INSURER B:N/A N/A SolarCity Corporation 3055 Clearview Way INSURER C:NIA N/A San Mateo,CA 94402 INSURER D:American Zurich Insurance Company 40142 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002681782-08 REVISION NUMBER:5 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER IPOLICYEFF/YYYY POLICY IYYYY LIMITS LTRJ=WVD A X COMMERCIAL GENERAL LIABILITY GLOO182016-01 09101/2016 0910112017 EACH OCCURRENCE $ 3,000,000 DAMAGE TOCLAIMS-MADE M OCCUR PREMISES Ea occurrence $ 3,000,000 X SIR.$250,000 MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 3,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 6,000,000 q POLICY❑JECT E LOC PRODUCTS-COMP/OPAGG $ 6,000,000 OTHER $ A AUTOMOBILE LIABILITY BAP0182017-01 09/01/2016 09/01/2017 (CEO accidentSMBINED INGLE LIMIT $ 5,000,000 X ANY AUTO BODILY INJURY(Per person) $ X ALL OWNED X SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS X NON-OWNED PeOPERaccident)DAMAGE $ X HIREDAUTOS AUTOS $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ D WORKERS COMPENSATION WC0182014-01(AOS) 09/01/2016 09/01/2017 X STATUTE oRH AND EMPLOYERS'LIABILITY D ANY PROPRIETORIPARTNER/EXECUTIVE Y/N WC0182015-01(MA) 0910112016 09/01/2017 EL EACH ACCIDENT $ 1,000,000 A OFFICER/MEMBER EXCLUDED? N/A 11 EWS 018208-0CA (Mandatory In NH) ( ) 09/01/2016 09/01/2017 EL DISEASE-EA EMPLOYE $ 1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below Limits appy I excess of$500K SIR-CA El DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) Evidence of insurance CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971-0959 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services StephanieGuaiuml r a �«sv�w• ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD STATE OF NEW YORK WORKERS'COMPENSATION BOARD CERTIFICATE OF INSURANCE COVERAGE UNDER THE NYS DISABILITY BENEFITS LAW PART 1.To be completed by Disability Benefits Carrier or Licensed Insurance Agent of that Carrier 1 a.Legal Name and Address of Insured(Use street address lb.Business Telephone Number of Insured only) 650-963-5100 1 c.NYS Unemployment Insurance Employer Registration SolarCity Corporation Number of Insured 3055 Clearview Way San Mateo,California 94402 1d.Federal Employer Identification Number of Insured or Social Security Number 02-0781046 2.Name and Address of the Entity Requesting Proof of 3a.Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) CIGNA LIFE INSURANCE COMPANY OF NEW YORK Town of Southold 3b.Policy Number of entity listed in box"1 a": 54375 Main Road NYD075344 Southold,NY 11971 3c.Policy effective period: 06/01/2016 to 06/01/2017 4. Policy covers: ®a.All of the employer's employees eligible under the New York Disability Benefits Law ❑b. Only the following class or classes of the employer's employees* Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named Insured has NYS Disability Benefits insurance coverage as described above. Date Signed: May 26,2016 By: (Signature of insurance carner's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number: 1.866-761-4236 Title: Underwriting Director IMPORTANT: If box"4a"is checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If box"4b"is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the Disability Benefits Law.It must be mailed for completion to the Workers'Compensation Board,DB Plans Acceptance Unit,328 State Street,Schenectady,New York 12305 PART 2.To be completed by NYS Workers'Compensation Board (Only if box"4b"of Part 1 has been checked State Of New York Workers'Compensation Board According to Information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability Benefits Law with respect to all of his/her employees. Date Signed By (Signature of NYS Workers'Compensation Board Employee) Telephone Number Title Please Note: Only insurance carriers licensed to write NYS disability benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. 1313-120.1(12-13) SolarCity D MAR 2 7 2017 March 23, 2017 B'MDING DEFT. Town of Southold Building Department TOWNOFSOUTHOLD P.O Box 1179 Southold, NY 11971 RE: Permit#41127 I am requesting an updated electrical certificate since the system size; has increased fromi 5kw to kw. I have included the updated plans. a 1 — Address is: 65 Garden Court Southold, NY 1971 a -�`b 1 I am the applicant Anais Fernandez with SolarCity Corp. My phone is 631-355-5125 or email afernandez1(a)-solarcity.com. Please advise if you have any questions. Best Regards, Anais Fernandez Permit Coordinator afernandezl@solarcity.com 923C Motor Pkwy.,Hauppauge,NY 11788 T (888)SOL-CIIY solarcity.com AL 05500.AR M-8937.AZ ROC 24377VROC 245450.CA CSLB 888104;CO EC8041.CT HIC 0632778%ELC 0125305.DC 410 514 0 0 0 0 8 0/ECO902585,DE 2011120386/T1-6032.FL EC13006226.HI CT-29770:IL 15-0052.MA HIC 168572/ EL-1136MR.MD HIC 12 8 9 4 8/118 05,NC 30801-U.NH 0347C/12523M,NJ NJHIC#13VH06160600/34EB01732700.NM EE98-379590.NV NV20121135172/C2-0078648/B2-0079719.OH EL.47707,OR CB180498/C562.PA HICPA077343.RI AC004714/Reg 38313.TXTECL27006.UT 8726950-5501.VA ELE2705153278,VT EM-05829,WA SOLARC•9190V50LARC'905P7.Albany 439.Greene A-486.Nassau H2409710000,Putnam PC6041.Rockland H-11864-40-00-00;Suffolk 52057-H,Westdhestgr WC-26088-H73,N.Y.0#2001304-0CA SCENYC:N.Y.C.Licensed Sectrlcian,#12610,#004485.155 Water St 6th Fl..Unit%1,Brooldyn,NY 11201.#2013966-0CA All loans prodded by SolarClty Finance Company.I.I.C. CA Finance Lenders License 6054796.SolerClty Finance Company,LLC Is Ilcensed by the Delaware State Bank Commissioner to engage In business In Delaware under license number 019422.MD Consumer Loan License 2241,NV Installment Loan License,IL11023/I1-11024.Rhode Island Licensed Lender#20153103LL.TXRedstered Creditor 1400050963-202404.Vr Lender License#6766 Version#63.5-TBD ° ' PIL = ;;SolarClt .� October 4, 2016 RE: CERTIFICATION LETTER R U V D Project/Job# 1191390 Project Address: Cochran Residence MAR 2 7 2017 65 Garden Ct Southold, NY 11971 AH] Southold Town BUILDING DEFT• SC Office Long Island TOWN OF SOUTHOLD Design Criteria: -Applicable Codes= 2016 Residential Code of NY State,ASCE 7-10,and 2012 NDS - Risk Category= II -Wind Speed = 135 mph,Exposure Category C -Ground Snow Load = 20 psf - MP1: 2x10 @ 16"OC, Roof DL= 14 psf, Roof LL/SL= 15 psf(Non-PV), Roof LL/SL= 7.8 psf(PV) Note: Per IBC 1613.1; Seismic check is not required because Ss=0.19994 < 0.4g and Seismic Design Category(SDC) = B< D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the existing structure directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes,for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. of NEI�i �2 K• Zq 0 C Paul Zacher, P.E. Professional Engineer '— T: 916.961.3960 x101 'li - : w email: paul@pzse.com O 91365.� ssioNP�' 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com ALi JR1 6^37.t_ROC 14}77-0•_; �5C`.CA i5LG 63AY_d.COFC&,N:1.CT HIG i`:.3:778i[LC Ol2:u?�.LC Rtr__�deY")EOr ECC9O,5+:CF.W]t2JZn5 J T:-ro31 FL ECt*gib??a.NI CT-29I 70_+ L2.M A,!C'.L?5•'IJ NH 0zJV!tl15 .N.ltl„IIICP f3'in-ol•.OcO!134E':iU 17;:.Tri4 r:6t FL<l-3:�- J.r•'l V—'Q]?r i5 C?:l �A:C<'3.r" 'rT'9,C'1E r].OR Cfs'd0 t.•!.v 4Ci•?<' .,y?7Ti;Ti.TECLS- VT 67_!9ZK "'1.'J^ELE2N�F1"_S'T6.1,EM';629.' SOLepc•'".;OVSCt%•Rv` _ ny a3 >-a,-. ;1:.-v H�- _ i R ,- . -1. 1JV>;7nr;rv.Fu,'r>r FCcC 1. :tYl�nh!':1.9oF,, O0-G4 iv'r ..:GC:'-n tve;t.}..:t•.at•IC-Te.'¢3F-H�3r:+1'C.?`�1SR.00n SCEr1Y t;;r; LI_ oc E1�. n a;1L10 nnn.].t9:..v,., >< rvUh. „I 4.�E�cH•:,.rig- ✓ ]t_Gi a rill^ .-G^ vf1 .r:fe7 Lv$rfa•C i`;F,r ,c �,.r.>.+y.•r;C CAFfn ',,tine{,_[}L—I.W:.CNJT, .`..)13r i`Jsie+ a•C'en,a9nv.:,L L:'irrto nl:J near ,nf• :Ire..n. •.,rLflGa ,j1G Cnn ,rx>rl<an l`�-z.rrJ..,. ,.. Inst't1m•.ntk-111:,.r•.a11.11_17;/It 111"^1.F1r Lk. It U'r'a-rj1:.`'i M1l:.l:�t'l:Nc, ccl4Grtl',t:.r]JJ?dt7...,7t+_•1�:,J"Lar o,.-Irn„r+•>Rtlpt, -1 V \s Version#63.5-TBD •I®\SolarGt PIL . HARDWARE DESIGN-AND STRUCTURAL ANALYSIS RESULTS SUMMARY,TABLES.',:; Landscape Hardware'-Landscape.Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever . Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPi 64" 24" 39" NA Staggered 54.4% 'Portrait .•. Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPi 48" 20" 65" NA Staggered 67.8% Structure 'Mounting Plane Framing. ., Qualification Results Type Spacing Pitch Member Evaluation Results MPi Vaulted Ceiling 16"O.C. 370 Member Analysis OK Refer to the submitted drawings for details of information collected during a site survey.-All member analysis and/or evaluation is based on framing information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. 3055 Clearvlew Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com AL 0551t).A:I4-3e;7.A.ROC 2b377/,RrC 26.Il5').Ca CSl38it6K�f..0 ECu Jsl.C7 reX:ObY•2/?R,ELC 0145:sC5,DC atJt'.IlGP)OSC!:ECCcp?�;;�.D'e 5%��1;0::]517:-:.6L2,FL ECt3C++J222,:ai CT-2:7'0.!1 EL-n3rv:r,n+t7l+Ic t�%ro:e,,:+cr.,�;ca,�;ot-�',nH ola;Cl17523`A.t{J:I.Aii(g1�VHl+_:,,�rgp.jIlCfl}li3"_.>ii�(JI•!EE`+0-319350 tiJ:�Vl3i2!:=5�j_!�;?-�•J7C!eIl8•Fi?_,-J.,7�'I:%.::�EI�31i.i.C4�:FrS:U:"•E.`�_�._.i-=}C�Qt.)�='�-*,-i'i ArC�;a711,P•v�aa5.7R iECl21's)b.01"13725o5••-5501.VA ECE?]65` ':B.N`4-05d29.' dJIA= 'OSRCl/SOtr!NC'oiHF Arzh�;a3.G•-v,� -13G.7tssau wl.f;chin - /. PA.'—, A.' „2r15i-•1.P:->t<he:hp v:P:ei'9R-M n",CX?CCPRIl-SICA LCE>rif:NYC LL: ...p Es=trl:� WL^.6 K1.&�10Jd 15 sr.-�S %th P,tlnl t� � ac r,»:.e<� CAFkrann?CznC:rrL:<m:a eC.5:74;SnlsrfiC Finnncn Cone �'' 't'• t .firGON.n, _}S_.c,;,-p,...ars:aanscrc nO•_a ..L.--ir.uT ,_-2-%N'/.1,C y [c.y.LLt'.I:�I�::n:.aa b�e tnn DdaN egcnk Cumrnlc,iw..x,,o cn;;v�x ::In Dc:tacro rticq•:c-���,ni�zr pt04^2 VO Ce... ::lanr L.�:_m:. :.t:: I'mom.'t Lo Ljcee ILM23/ft11024.-1 Li.�nvaj!'c d, Gc60Z!409J`,04i-�•3. '.:.'�ii2•m:t2'L::+' STRUCTURE ANALYSIS,- LOADING SUMMARY AND.MEMBERCHECK-, MPi; �"T Member Properties Surninary MPl Horizontal Member Spans , Rafter Pro erties Overhang 1.16 ft Actual W 1.50" Roof System Pro erties San 1 16.18 ft Actual D 9.25" Number of Spans(w/o Overhan 1 San 2 Nominal Yes Roofing Material Comp Roof San 3 A inA2 13.88 Re-Roof No San 4 Sx(in.A3) 21.39 PI wood Sheathing Yes San 5 Ix inA4 98.93 Board Sheathing. None Total Rake Span 21.71 ft TL Defl'n Limit 180 Vaulted Ceiling Yes PV 1 Start 1.50 ft Wood Species SPF . Ceilino Finish 1/2"Gypsum Board PV 1 End 14.75 ft Wood Grade #2 Rafter Sloe 370 PV 2 Start Fb(psi) 875 Rafter Spacing 16"O.C. PV 2 End Fv(psi) 135 Top Lat Bracing Full PV 3 Start E(psi) 1,400,000 Bot Lat Bracing Full PV 3 End E-min(psi) 510,000 Member Loading mary Roof Pitch 9 12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 14.0 psf x 1.25 17.5 psf 17.5 psf PV Dead Load . PV-DL . 3.0 psf x 1.25 3.8 psf Roof Live Load RLL 20.0 psf x 0.75 15.0.psf Live/Snow Load LL/Sl."2 20:0 psf x 0.7 1'x 0.39 14.0 psf 7.8 psf Total Load(Governing LC ,, 'TL ' •31.5psf' 29.1' 'sf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(C0(IS)pg; Ce=0.9,Cr=1.1,I,=1.0. Member Design Summary(per NDS Governing Load Comb CD - CL + CL - CIF 17 Cr D+.S :1.15 1.00 1.00 1.1 1.15 Member Analysis Results Summary Governing Analysis Max Moment @ Location Capacity DCR Result + Bending Stress(psi) 703 9.3 ft 1,273 0.55 Pass CALCULATION:OF:DESION WIND_LOAM MPI-7- Mounting Plane Information Roofing Material Comp Roof { Roof Slope 370 Rafter Spacing 16"O.C. ; Y-Y Rafters PV System Type _ _ �__ _ SolarCity SleekMount Tm Zep System Type -� - __ ZS Comp Standoff Attachment Hardware - -_ Como Mount Type C Spanning Vents No Wind Design Criteria Wind Desi n Code IBC 2015 ASCE 7-10 Wind„Design Method ___ : __. ._._.-__. yPartially/Fully,Enclosed MethodW_ Ultimate Wind Speed _ ___. _._V-Ult _.._.___. 135 mph _.— __. _._.. Fig._1609A .V Exposure Category Roof Style _ — Gable Roof Fig.30.4-2A/B/C-5A/B Mean Roof Height T_ --- �-- n __---25 ft Section 26.2 - Wind Pressure Calculation Coefficients Wind Pressure Exposure_-�_-- _-. _ K=_-_-_. -. 0.95 -- - Table 30.3-1 _...�....__..__.._._..-..1:00 _ ,�..._.a__.........,_._.._. Section26.8 _.. Wind Directionality Factor Kd 0.85 Section 26.6-1 _ _.. _�_. ._-_.._______._.__ _._ __-_-------. ___-..__-._.__ .__ Im ortance Factor I NA Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2) Equation 30.3-1 37.5 psf Wind Pressure Ext. Pressure Coefficient U GCp(Up) -0.95 Fig.30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down GC Do n 0.88 Fig.30.4-2A/B/C-5A/B Design Wind Pressure p p=qh(GCp) Equation 30.4-1 Wind Pressure Up p° -35.6;psf . Wind Pressure Down 32.8'psf . i ALLOWABLCSTANDOFF SPACI_NGS_,.rT__ X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever- __Landscape___— - _y _ 24"_ .. .__ __— NA - Standoff Confi uration Landscape Staggered Max Standoff Tributary_Area___�_` _ Trib __. , ._ 17 sf PV_Assembly Dead Load i — W-PV_ y4 ___^ _ 3.0_psfNet Wind Uplift at Standoff _. e •__T-actual -346 Ibs Uplift Ca aci of Standoff T allow _ 637 Ibs _ P tY _.... ___......__.. _.._. . _.-. —.�._. .. _..__.,....._., ..... Standoff Demand Ca aci DCR 54.4% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever - _ __-__ Portrait 20" _ _ _ __-NA_--- Standoff Configuration Portrait Staggered Max Standoff,Tributary_ _Are _a Trib 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift-at Standoff__. _ .__. T-actual _ - ,432 Ibs - Uplift Capacity of Standoff T _ T-allow Ca Standoff Demand aci DCR 67.8% ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERIIED .VIA A _ AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO ,UPS. CONC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL.LIST- ALL EQUIPMENT IN. EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING. MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART: 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG -HOT DIPPED GALVANIZED PHASE AND.SYSTEM PER ART. 210.5. CURRENT 6. CIRCUITS .OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY'WITH ART. 250.97, 250.92(B). Isc -SHORT CIRCUIT CURRENT. 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN .IN METALLIC RACEWAYS OR kW. KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW' LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL'WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE,FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL-LISTED LOCATION PROVIDED. BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI .POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE.FRAMES, RAIL,-AND POSTS.SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC . STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPIIBLE POWER SUP V VOLT D v D Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT MAR 2 7 2017 PV1 COVER SHEET 3R NEMA 3R, RAINTIGHT 1 PV2 SITE PLAN PV3 STRUCTURAL VIEWS DEPTH PV4 THREE LINE DIAGRAM LICENSE, TOwN0F ouTHoaNERAL NOTES cutsheets Attached 1. ALL WORK SHALL COMPLY WITH THE 2615 IBC AND 2015 IRC 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR P `� REV BY AHJ: Southold Town DATE COMMENTS • � REV A RM 9J28/16 CUSTOMER REQUESTED UPSIZE REV B RM 10/24/16 ADDED ONE MODULE 11/2eJ16 Modules Swapped UTILITY: PSE&G-Long Island (Public Serce Electric ' �, Rlvc SBRAN vi & Gas Co.) � • � =Cel ■ � � - a • J B-1191390 0 0 �°"' 0H1�Qt` ol3(NtIPnDN: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: ���e ■ CONTAINED SHALL NOT BE USED FOR THE ROBERT COCHRAN . Robert Cochran RESIDENCE Bobby Morsch �;;,So�arCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: o' m NOR SHALL IT BE DISCLOSED IN VMOLE OR IN ZS Comp V4 w Flashing-Insert 65 GARDEN CT 6:375 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MaDULES SOUTHOLD NY 11971 ORGANIZATION, EXCEPT IN CONNECTION VATH i 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (25) TRINA SOLAR # TSM-255PD05.18 PACE NAME SHEET: REV DATE; San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER. T:(650)638-1026 F:(650)638-1029 PERMISSION OF SOLARCITY INC. S GE SE6O00A-US000SNR2 COVER SHEET PV 1 e 2/17/2017 (sea)-Sa-NTY(765-2489)www.solarcity.aam PITCH: 37 ARRAY PITCH:37 MP1 AZIMUTH:148 ARRAY AZIMUTH:148 MATERIAL:Comp Shingle STORY. 2 Stories of NE�y K. 24 y0,p r— w 0 W P. OA E3 -i - - -- l LEGEND l Q (E) UTILITY METER & WARNING LABEL C al ——— INVERTER W/ INTEGRATED DC DISCO iv% I� & WARNING LABELS fn Ml I l DC DISCONNECT & WARNING LABELS I___ © AC DISCONNECT & WARNING LABELS l ' 'I p Cm 0 DC JUNCTION/COMBINER BOX & LABELS t. I � Q mpi DISTRIBUTION PANEL &.LABELS A 0 LOAD CENTER & WARNING LABELS O DEDICATED PV SYSTEM METER Front Of House RSD(E) DRIVEWAY RAPID SHUTDOWN . ® STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR . -- CONDUIT RUN ON INTERIOR 65 Garden Ct. GATE/FENCE Q HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L_-J . SITE PLAN N Scale: 1/8" = 1' 01' 8' 16' F J B-1191390 0 0 PREMISE OWNER DE�IaPnoN: DESIGN: CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: �\mta ■ CONTAINED SHALL NOT.BE USED FOR THE ROBERT COCHRAN Robert Cochran RESIDENCE Bobby Morsch . ':,;So�arCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: of NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 65 GARDEN CT 6.375 KW PV ARRAY. PART TO OTHERS OUTSIDE THE RECIPIENT'S MaOUIEs SOUTHOLD NY 11971 ORGANIZATION, EXCEPT IN CONNECTION WITH , 3055 CleaMer Way THE SAL:AND USE OF THE RESPECTIVE (25) TRINA SOLAR # TSM-255PD05.18 PACE NAME SHEET: REV: DATE San Mateo,CA-94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE6000A—USOOOSNR2 SITE PLAN PV 2 e 2/17/2017 (888)—SOL-aTY(765-2489)mww.ealarcity. (E) 2x8 S1 „ 16'-2" of NEfN (E) LBW K. Z,q cy�0 A SIDE -VIEW OF MP1 NTS � � r � 0 W MP-1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" 39" 0" STAGGERED �,p 9136525 PORTRAIT 48" 20" 64" 0" PV MODULE R��ESSIONP� RAFTER 2X10 @ 16"CIC ARRAY AZI 148 PITCH 37 STORIES: 2 5/16"X1.5" BOLT WITH Comp Shingle 5/16" FLAT WASHER INSTALLATION ORDER ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE ZEP ARRAY SKIRT (1) LOCATION, AND DRILL PILOT HOLE. --------- --— -------- ZEP MOUNTING BLOCK (4) ATTACH FLASHING INSERT TO AND ATTACH ZEP FLASHING INSERT (3) E2) MO R FTEROUNTINGBLOCK USING LAG SCREW. (E) COMP. SHINGLE (1) . . INJECT'SEALANT. INTO FLASHING (E) ROOF DECKING (2) (3) INSERT'PORT, WHICH SPREADS SEALANT EVENLY OVER THE 5/16" DIA STAINLESS ROOF PENETRATION. STEEL LAG .SCREW LOWEST MODULE ` SUBSEQUENT MODULES (2-1/2" EMBED, MIN) INSTALL LEVELING FOOT ON TOP C(4) OF MOUNTING BLOCK & . (E) RAFTER SECURELY FASTEN WITH BOLT. S1 STANDOFF . CONFIDEN J B-11913 9 0 00 PREMISE OWNER. DESORPTION: DESIGN: TIAL- THE INFORMATION HEREIN JOB NUNBER: \c�4a �. CONTAINED SHALL NOT BE USED FOR THE ROBERT COCHRAN Robert Cochran RESIDENCE Bobby Morsch WHOL I„�OIar�I�y BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: o. NOR SHALL IT BE DISCLOSED IN E OR IN ZS Comp V4 w Flashing—Insert 65 GARDEN CT 6.375 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MaomFs SOU TH OLD N Y 11971 ORGANIZATION, EXCEPT IN CONNECTION WT1H , 3055 Cleardew Way THE SALE AND USE OF THE RESPECTIVE (25) TRINA SOLAR # TSM-255PDO5.18 PACE Nave SHEEr REV DATE. son Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION of SOLARCITY INC. SOLAREDGE SE6000A—USOo0SNR2 STRUCTURAL VIEWS PV 3 e 2/17/2017 (888)—SOL—CITY(�65-2489)winisaa.altyaom l GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number:NoMatch Inv 1: DC Ungrounded INV 1—(1)SOLAREDGE&SE6000A—USOOOSNR� LABEL; A —(5)TRINA SOLAR # TSM=255PDO5.18 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:75 056'369 Inverter; 60 OW, 24OV, 97.57 w Unifed Disco and ZB,RGM,AFCI PV Module; 255W, 232.2W PTC, 40MM, Black Frame, MC4, ZEP, 1000V Underground Service Entrance INV 2 " Voc: 38.1 Vpmax: 30.5 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER- (E 200A MAIN SERVICE PANEL E; 150A/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING 1 150A/2P 3 0A—U 000DGE DC- SE6000A—USOOOSNR2 Da- MP 1: 1x12 F FL (E) LOADS --------------------=----- ------------------- EGO _J L1 zaov r -------- L2 DO+ N DC- I. 2 35A/2P B I EGC. DC.+ — ---------------------------- ----- GEC ._". -MP 1- x�----------- 13 JA GGN ------=---— —-- I __J I(I)Conduit Kit; 3/47 BAT . . . N EGCIGEC - - - o --- CD --- GEC . . . . . . . . TO 120/240V" SINGLE PHASE UTILITY SERVICE I I I I r • I I EGC ON ROOF TO BE ROUTED WHERE NOT SUBJECT TO PHYSICAL DAMAGE. WHEN ROUTED SUBJECT TO PHYSICAL DAMAGE THE SIZE MUST BE INCREASED TO #6 SOLID BARE COPPER. Voc* = MAX VOC AT MIN TEMP OTT (1)CUTLER—HAMM R #BR235 PV BACKFEED BREAKER PV (25)SOLAREDGE N P300-5NM4ZS l Breaker, 35A/E2P pumizer,300W, ZEP,in MC4,out MC4 DC —0)Gropr`d Rod 5 8 x 8, Copper 1 AWG J8, THWN-2, Black 500 VDC I 8 63 ADC 1 2 AWG�10, PV Wire, 600V Block Voc* 500 VDC Isc 15 ADC O L_L(1)AWG y8, THWN-2, Red O (1)AWG#6, Solid Bare Copper EGC Vmp = mp= C (1)AWG#10, THWN-2,White NEUTRAL Vmp =240 VAC Imp=25 AAC (1)Conduit Kit; 3/4' EMT -(1)AWG(r8,.TF1WN-2,•Green ..T99/9P.70).C�p4u.it.).Conduit•Kit;•3/4":EMT.•. ..•••. (2)AWG g10, V Wire, 6004, Bladc Voc* =500 VDC Isc=15 . ADC .P O1)AWG#6,Solid Bare Copper EGC Vmp =350 VDC Imp=9.35 ADC (1)Conduit Kit:•3/4'.EMT... .... .......... .............. .. . ... .. J B-11913 9 0 0 0 POSE D"NE DFSCRIPnON: oLSIGN: CONFIDENTIAL—THE INFORMATION HEREIN JOB NUISBER: ■ Bobby Morsch ;;,SolarC�ty. CONTAINED SHALL NOT BE USED FOR THE ROBERT COCHRAN. Robert Cochran RESIDENCE y BENEFIT�ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 65 GARDEN CT 6.375 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES. SOUTHOLD NY 11971 .ORGANIZATION, EXCEPT IN CONNECTION WITH r 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (25) TRINA SOLAR # TSM-255PDO5.18 PACE NAME SHEER REV; DATE: San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE6000A—USOOOSNR2 THREE LINE DIAGRAM PV 4 e 2/17/2017 (888)-SOL-CITY(765-2489)www.solarcity.com WARNING:PHOTOVOLTAIC POWER SOURCE "' ' Label Location: Label • Location: WARNING WARNING ' Per Code:� ELECTRIC SHOCK HAZARD Code: ..- NEC , ELECTRIC SHOCK HAZARD' 1 NEC ' 1 NEC �.1 DO NOT TOUCH TERMINALS THE DC CONDUCTORS OF THIS Label • TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE TO BE INVERTERIS PHOTOVOLTAIC DC LOADN THE OPEN POS TIONIZED MAY BEOENERGIZED DISCONNECT UNGROUNDEDPer Code: NEC .•1 LabelLabel Location: Location: PHOTOVOLTAIC SYSTEM MAXIMUM POWER _A Per Code: POINT CURRENT(Imp) Per Code CEC 690.56(C) MAXIMUM POWER- POINT VOLTAGE(Vmp) VNEC 690.53 MAXIMUM SYSTEM V VOLTAGE(Voc) SHORT-CIRCUIT A CURRENT(Isc) Label L• WARNING '• Per ..- NEC INVERTER OUTPUT CONNECTION 690.64.13.7 Label • DO NOT RELOCATE WARNING Per THIS OVERCURRENT DEVICE ••- NEC ELECTRIC SHOCK HAZARD .1 IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZEDLabel L• - • CAUTION ' Per ..- PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED NEC 690.64.13.4. Label . • WARNING ' Per ..- ELECTRICALSHOCK HAZARD DO NOT TOUCH TERMINALSNEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED CAUTION • IN THE OPEN POSITION DUAL POWER SOURCEPer Code: DC VOLTAGE IS SECOND SOURCE ISNEC 690.64.13.4 ALWAYS PRESENT WHEN PHOTOVOLTAIC SYSTEM SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • PHOTOVOLTAIC POINT OF '• .•- • • INTERCONNECTION PHOTOVOLTAIC AC Code:Per • WARNING:ELECTRIC SHOCK • ' AC Disconnect _ HAZARD. DO NOT TOUCH ' 1 NEC 690.54 • • DISCONNECTCode:1 TERfv11NALS.TERMINALS ON _ NEC BOTH THE LINE AND LOAD SIDE ' ' Panel' MAY BE ENERGIZED IN THE OPEN • • POSITION. FOR SERVICEDisconnect DE-ENERGIZE BOTH SOURCE _ AND MAIN BREAKER. 'r Run ' ' Label • • PV POWER SOURCEuit Integrated DC Disconnect MAXIMUM AC ' • MAXIMUM AC A Load Center CURRENT A Per Code: OPERATING CURRENT Meter(M): Utility MAXItv1UM AC MAXIMUM AC OPERATING VOLTAGE � V 690.54 OPERATING VOLTAGE � V (POI): Point of Interconnection 3055 Clearview Way :130 MI X VOINIM TU W*61 ffilzib'Ifm U 1'P hi I m 10 1-1:111 Rik ILIP San Mateo,CA 94402 1 1' 1 1 T / 1 1' 1' / 29 •- • 1- •1 1 •1 I 1 1 1 1 • r 1 ••• 1 7 1 7 '7' l/- 1 1 \\1i CS6P-235/240/245/250/255PX _r CanadianSolar i Electrical Data Black-framed Temperature Characteristics STC CS6P-235P CS6P-240P CS6P-245P CS6P-250PXCS6P-255PX p Nominal Maximum Power(Pmax) 235W 240W 245W 250W 255W _ _ - Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30.1V 30.2V Pmax -0.43%rc - Optimum Operating Current(imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Voc -0.34%rc - Open Circuit Voltage(Voc) 36.9V 37.OV 37.1V 37.2V 37AV Isc 0.065%rC " Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature 45t2°C Black-framed • Module Efficiency 14.61% 1 14.92% 1 15.23% 1 15.54% 15.85% -Operating Temperature -40'C-+85'C Performance at Low Irradiance _ Maximum System Voltage 1000V IEC)/600V UL Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an ' Application Classification ClassA irradiance of 1000w/m'to 200w/m'- ' Power Tolerance 0-+5w (AM T.5,25'C)' Next Generation Solar Module - Under standard Test Conditions(STC)ofirradiance,of 1000WIm',spectrum AM 1.5 and cell temperature of25•C " NewEdge,the next generation module designed for multiple Engineering Drawings NOCT CS6P-235PXCS6P-240PXCS6P-245PXCSVP 250PXCS6P-255PX types of mounting systems,offers customers the added Nominal Maxiinum Power(Pmax) 170W 174W 178W 181w 186W value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27,2V 27.3V 27AV 27.5V 27.5V appearance,auto groundingand theft resistance. Optimum operating Current(imp) 6.27A 6.38A 6.49A 6.60A 6.71A - Open Circuit Voltage(Voc) 33.9V 34.OV 34.1V 34.2V 34AV The black-framed CS6P-PX is a robust 60 cell solar module Short circuit Current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A _ - incorporating the groundbreaking Zep compatible frame. under Normal Operating Cell Temperature,Irradiance ofa00W/m',spectrumAM LS,ambient temperature 20C, The specially designed frame allows for rail-free fast wind speed 1 m/s installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6 x 10) y , with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638x982x40mm(64.5x38.7x1.57in) • Quick and easy to install - dramatically, is the perfect choice for customers who are looking for a high weight 20.5kg(45.21bs) reduces,installation time quality aesthetic module with lowest system cost. Front Cover 3.2mmTempered glass Frame Material Anodized aluminium alloy • Lower system costs - can cut rooftop Best Quality J-Box IP65,3 diodes installation costs in half . Cable 4mm2(IEC)/12AWG(Ul_),1000mm . 235 quality control points in module production Connectors MC4 or MC4 Comparable • Aesthetic seamless appearance - low profile • EL screening to eliminate product defects standard Packaging(Modules per -24pcs_- __ _ - with auto leveling and alignment Current binning to improve System performance Standard Pieces per container(40 ft.Container) 672pcs(40'HQ) • Accredited Salt mist resistant • Built-in hyper-bonded grounding system if it's I mounted,it's grounded I-V Curves(CS6P-255PX) Best Warranty Insurance • Theft resistant hardware • 25 years worldwide-coverage j • 100%warranty term coverage SectionA-A Ultra=low parts count - 3 parts for the mounting • Providing third party bankruptcy rights 3.0 and grounding system • Non-cancellable • Industry first comprehensive warranty insurance by • Immediate coverage AM Best rated leading insurance companies in the Insured by 3 world top insurance companies world: _ - Comprehensive Certificates • Industry leading plus only power tolerance:0-+5W . IEC 61215,IEC 61730, IEC61701 ED2,UL1703, ""'' —`ti t5 • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS ground mounting systems • ISO9001:2008:Quality Management System - • ISO/TS16949.2009-The automotive quality 'Specifications included in this datasheet are subject to change without prior notice. • Backed By Our New 10/25 Linear Power Warranty management system Plus our added 25 year insurance coverage • ISO14001:2004:Standards for Environmental About Canadian Solar management system Canadian Solar Inc. is one of the world's largest solar Canadian Solar was founded in Canada in 2001 and was 10s�1 A • QCOSOOOOHSPM:TheCertificationfor companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) in Added Value Fro Hazardous Substances Regulations manufacturer of Ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing so% rn Warranty 9 solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. • OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide so% occupational health and safety customers. Canadian Solar's world class team of o� s 10 1s zo zs REACH Compliance professionals works closely with our customers to provide them with solutions for all their solar needs. Headquarters 1545 Speedvale Avenue West OntarioGuelph I •10 year product warranty on materials and workmanship •25 year linear power output warranty 1881 • f WWW.Canadiansolar.com EN-Rev 10.17 Copyright o 2012 Canadian Solar Inc. solar a r=eeSingle Phase Inverters for North America soIar _ SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE760OA-US/SE1000OA-US/SE1140OA-US SE3000A-US SE3800A-US SE5000A-US SE6000A-US SE760OA-US I SE10000A-US 'SE11400A-Us OUTPUT 9980 @ 208V SolarEdge Single Phase Inverters Nominal AC Power Output 3000 3800 5000 6000 7600 990@208V,. 11400 VA Max AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA For North America ......... .. . ... ........ ............ .......... . .545D.�240V. .. .. ... ... .�0950.@240y. . ....... AC Output Voltage Min:Nom:Max.t'I Vac ............................................. . ..... ................. ................ ................ .................................... ........... SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ AC output Voltage Min:Nom:MaX117 I .1 SE760OA-US/SE1000OA-US/SE1140OA-US 211-240-264Vac . .11-2...-264........................ ................ ............... ..:.............. ............... ................ .................................... ........... AC Fre uen Min:Nom.Max.t'1 -....,•... .,,,,,.•,•, 59.3:60:60.5•,.,•••,••., .•• ,.•._, ,,, Hz IG ,,,, ' Max.Continuous Output Current 12.5 16 208V ..•.25. 32 48 208V 47.5.... .•A.'.•. G d ',4( I -24 @ 208V..I ...42 @ 240V..... .. „GId •-, ....... ... .. �° @..........L................. . . .. .... M:, ..GFDIThreshold ..?. ,A. i Utility Monitoring Islanding Protection Country Configurable Thresholds Yes Yes k INPUT f. 6 50 8100 10250 13500 15350 W 5 00 7 4050 1 ..� - Maximum DC Power(STC) .... ........... .. . . . .. .. ... .... ................ ................................... ......... ...... ... .... .. ... ... ..... Transformer-Iess,.Ungrounded...... ........................................................Yes. ......................................... - ......... ... a ... .,,..,... npu Itage _ 900 Max:... ?..4. ................ ..................................... .... .. .... ........................................................... A.=` .. _._,� , •-;v Rarity m�: .:� = -�r•` Input Voltage ........... 325 @.208V/,350 @ 240V....... .............. Vdc.... ;�Wa - -.-1s'"�''a' •e:� �� .�.,: - "e Nom.D.... . ..... ............... ........... L.16.5@208V. ....... ... ..... ...33@208V... .... Max.Input CurrenN�1 9.5 13 155 240V ( 18 23 30.5 240V 34.5 .'Adc v - _ Max.Input short Circuit Current 45 Adc tea. - ..:.., - otection Yes . ..... ......... Reverse Polarity.................... ................................................ ..... ......... ........ . .. .Ground-Fault Isolation Detection ...... ..98 98 98.• .. /. .......... ... .... ......... ............ ........... ............ ....... . .............. ......... CEC Weighted Efficiency 97.5 I 98 ..97 @ 208V I 97.5 97.5 .'.97 @ 208V 97.5 .' /o 98 240V 97;5 240V w1 ' k ............................ .............. ............... ... ......... ................ .............. @..................:........ . .. ... 4`n I`, Nighttime Power Consumption <2.5 <4 ...W ADDITIONAL FEATURES Supported ................................................... ............................................... ... ......... Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional) Revenue Grade Data:AN51 C12.20.. .... .............................................Optional(i1...................................................... ......... Rapid Shutdown—NEC 2014690.12 Yes NDCOMPLIANCE ----- --- STA ARD COMPLIAN E _ s Safety UL1741,UL17415At UL1699B,UL1998,CSA 22.2 "- - ^•.• . .j - - i s - rid Connection Standards IEEE1547................ •.•••.•....,...... ....... E .. ... .......... ......... £j� missions............................ ................... .......... .......FCC part15 class B ' INSTALLATION SPECIFICATIONS ., ` .. AC output conduit size/AWG range 3/4',m)nimum/16:6AWG 3/4"minimum_/8-3 AWG �a - - 34"minimum 1-3 strings, ,., •., �,; �s;, ,! DC input conduit size/#of strings/ _ / / / I4 WG 2nge•,,,,,,,,,, ,,,,,,,,,,, 12strings/16-6 AW 14-6 AWG 3/4"minimum/ G A„ .......................................................... .... ... .. ... . . . .... ... .... ., `. Dimensions with Safety Switch 30.Sx12.5x7.2/775 x315x184 rv',., ......... ...... ...... ............... ............... ........ .. .. .... „ , ..(HxWxD)•,.•,,,.,•,,,,,,,,•, 75x315x260 mm i Weight with Safety Switch............' . .........51.2/23:?..........L..................54.7/24.7... ... .........88.4/40.1.......... . ..'ti/kg... • - - - .. ..... ..... ......... .. ..... .. .... Natural convection Cooling Natural Convection and internal Fans(user replaceable) E fan(user . The best choice for SolarEdge enabled systems ; . :. .. ............................ re laceable). ............ ....... Integrated arc fault protection for NEC'2011690.11 compliance ) PRise <2s <so dBA_ .. .. . . . Min.-Max.Operating Temperature.... ................................................................. ........................ .................... .. Rapid shutdown for NEC2014690.1213to+140/-25to+60(-40to+60 version available(4)) 'F/'C _) .. l _ _. ,RanB?.................................. .......................................................................................................................... ........... Superior efficiency(98%) - Protection Rating NEMA 3R t ttl For other regional settings I......contact.......... .I.support................................................................................................................... ..... Small,lightweight and easy to Install on provided bracket („ 1 A h;gher current source maybe used;the invert,11 I ,t its input current to the values stated. Built-In module-level monitoringI - ) - ((I evenue g,adelnverter P/N:SEnaa A-US000NNR2(for 760DW[merter.SE7600A-US002NNR2). 40 version P/N:SExoaA-US000NNU4(for 760OW Inverter.SE7600A-Us0D2NNU4). Internet connection through Ethernet or Wireless Outdoor and indoor installation - - .,.:1 Fixed voltage inverter,DC/AC conversion only' Pre-assembled Safety Switch for faster installation Optional-.revenue,grade data,ANSI C12.20 ON M RoHS USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THENETHERLANDS-UK-ISRAEL www.solaredge.us N^SolarCity ®pSoLar Next-Level PV Mounting Technology SSolarGty I ®pSolar Next-Level PV Mounting Technology Components ZS COMP for composition shingle roofs o I Mounting Block Array.Skirt. Interlock Part No.850-1633 Part No.850-1608 or 500-0113, Part No.850-1388 or 850-1613 Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 -ww Flashing Insert Grip Ground Zep V2 Part No.850-1628 Part No.850-1606 or 850-1421 Part No.850-1511 Listed to UL 2703 Listed to UL 2703 Listed to UL 467 and UL 2703 O0104T1e r •� o/ Description PV mounting solution for composition shingle roofs FA 0. Works with all Zep Compatible Modules eWill Auto bonding UL-listed hardware creates structural and electrical bond • ZS Comp has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Captured Washer Lag End Cap DC Wire Clip U` LISTED Specifications No.850-1631-001 Part No. Part No.850-1509 Specifications 850-1631-002 (L)850-1586 or 850-1460 Listed to UL 1565 880=1631-003 (R)850-1588 or850-1467 • Designed for pitched roofs 850-1631-004 • Installs in portrait and landscape orientations • ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • ZS Comp grounding products are UL listed to UL 2703.and UL 467 • ZS Comp bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" �- • -Zep wire management products listed to UL 1565 for wire positioning devices Leveling Foot- Pan No.850-1397 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications aie subject to change without notice.Patents and Apps:zspats.com. Document#800-1839-001 Rev D Date last exported:April'29,201611:22 AM Document#800-1839-001 Rev D Date last exported:April 29,201611:22 AM solar - Sol a r=ggSolarEdge Power Optimizer - Zep Compatible T"" Module Add-On For North America P300-ZEP SolarEdge Power Optimizer P300ZEP(for60cellPVmodules) 7 Q n/� INPUT Zep Compatible TM Module Add-Oil Rated InputDCpowerltl 300 ........... w. .... .......... ......................................... .... .....-.. Absolute Maximum inputVoltage(Vocatlowesttemperature) . .................................... Vdc { ........ ............... ................................... For North America P3OO'ZEP MPPTOperatingRange 8.:48 Vdc ................. ............................... ..-......................................... ....- I a imum Short Circuit Current(Isc) .................................................................. .................................. Maximum DC Input Current 12.5 Adc . .....urre............................................... P1 I's k � t :� ri "' MaximumEfficien 99.5............... / vmc .................................. .............. y b Weighted Efficiency Overvoltage Category IL.... f ,rj` �* �r � r „*tip¢ a r OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) , ' Maximum Out ut Current ?tk+¢ry .................P.....................-.................................. 15 Adc Maximum Output Voltage 60..................................... Vdc..... r OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER-OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc Nf,,.r?fv ti�r STANDARD COMPLIANCE jr�•suejr.a;t f 3Te� zg :.:............,-J t Y f, EMC FCC Part15 Class B,IEC61000..2,IE...... 6 3 „ir.r •_q: ;�e;° --='• ">:P:� ° ,.a,F .Safety........ ..................................................... .................. . .( ....- „i h »t r' Mt x , RoHS :.(class safety);IEC62109 1 e INSTALLATION SPECIFICATIONS t vas Maximum Allowed System Voltage 1000 Vdc '.. •:. ..... ...... ..... ............ ... ............................. ..... .... .-. .................... ........... . ..... - • .t -�-;a=f-- ay`'' _ :�=:r�`' 3, a�F Dimensions including mounting bracket (W x L x H) 141 x 256 x 40.5/5.55 x 10.08 x i.59 ram/in ...................................... ........... ........... .. ............. ......................- ......... ..... 1ATss. Dimensions excluding mounting bracket (W x L x H) 141 x 212 x 40.5/5.55 x 8.34 x 1.59 ram/.. a ........................................................................ ..... ........ Weight(including cables and mounting bracket) 1170/2 54 kg/lb 4 P . o . ..-.... ........... .. .. . .. ....... . _.. "� ° In ut Connector MC4/Amphenol/Tyco ............................... . .................... ................... ......... .......... .. Output Connector Double Insulated;Am henol .... .. ........................ . Output Wire Length 0.95/3.0 P m ft I ........................................................... .................... .............. . n� ...Rz: Operating Temperature Range............. -40-+85/ 40-+185 C./..F... .... .... . .................................................................... . Protection Rating IP65/NEMA4 ........................................................................ Relative Humidity 0-100 (.............. .................... ... .................................................................................................................................................................... .. pl Rated STC power of the module.Module of up to+5%power tolerance allowed.. PV SYSTEM•DESI_GN USING A SOLAREDGE INVERTER -SINGLE PHASE THREE RHASE THREE PHASE ............................................. .. .. ........ s! k 208V 480V' . Mini • i -•-••--mum String Length Power Optimizers) •- .•---- ••• ----- 8••••-•- - 10 .••••- 18 • I a imum String Length((Power Optimizers) 25 25 s0 Compatible with Zep Groove framed modules ""' "' " _ Maximum Power per String.. ....................................... 5250..........�..........6000.......... .........12750... . �.. i Certified ZepCom atibleTT'bracket . — Miti ates all t es of module mismatch'losses,from i p g YP Parallel Strings of Different Lengths or Orientations Yes I •• •-•••-•-- ! —,Attaches to module frame without screws-reduces.on-roof ,' manufacturing tolerance to partial shading labor and mounting costs. = Flexible system design-for maximum space.titilization, Poweroptimiierequipmentgrounded,through the bracket - Next generation maintenance withmodule-levelmonitoring Up.to 25%'more energy Module-level.boltage shutdown for installer'and'firefighter, I safety Superior efficiency(99.5%) USA GERMANY ITALY FRANCE JAPAN CHINA ISRAEL AUSTRALIA www.solaredge.us r ON SOLARLDGL I � 1 , Version#63.5-TBD �•`"":� - "`,-S®IarCit .. PIL October 4,2016 APPROVEr; AS NOTED RE: CERTIFICATION LETTER DATE:Io .jL: #JLC-1-�0-_._. Project/Job# 1191390 3Y•C4 �P��...'?>M�.�,Ni._.,..-,..�.�..._ Project Address: Cochran Residence FEE: P�ILr - �, 65 Garden Ct NOTIFY BUI!�)t �G r Southold, NY 11971 765-1802 8 AM TO 4 PM FOR THE AHJ Southold Town FOLLOWING INSPECTIONS: SC Office Long Island 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE Design Criteria: 2. ROUGH - FRAMING & PLUMIBING 3. INSULATION -Applicable Codes= 2016 Residential Code of NY State,ASCE 7-10,and 2012 NDS 4. FINAL - CONSTRUC-i ION MUST - Risk Category= II -Wind Speed = 135 mph, Exposure Category C BE COMPLETE FOR C.O. -Ground Snow Load = 20 psf ALL CONSTRUCTION SHALL. MEET THE -MPI: 2x10 @ 16"OC, Rof CL--��1 ps,� q'@� L . sf(Non-PV), Roof LL/SL=7.�E(0�%MENTS OF THE CODES OF NEIN IS 99 �g9!6�g� �,W9��p��pL YORK STATE. NOT RESPONSIBLE FOR UWSE DESIGN OR CONSTRUCTION ERRORS. }BRIT T CERTIR TE F OCCUPANCY Note: Per IBC 1613.1; Seismic check is not required because Ss=0.19994 < 0.4g and Seismic Design Category(SDC) = B< D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation,I certify that the existing structure directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. OF NEWT K. Zq O Oyu �� O Paul Zacher, P.E. .. CODES OF t Professional Engineer ,, ,` _..F..;._„ i w T: 916.961.3960 x101 NEW� e.1: ,t� � ?f, i `— x TCS>�I'h] BODES 'i( -'' a, W email: paul@pzse.com AS R E 0 1 J I RE__D F- o AR�91365,,�,s��FES0 Pv n i V I- S1w\ 3055 Clearview Aa >5'CA'*t3�0� r tb 0 'b 6}1028 15�)��S "1 TY F(650)638-1029 w1arcity.com ? �;r 1'(Y' CF n'�tt,_(�.',5�1•:L�3,r1 FGA'^r, [7-t'>J7L,�15-te?c: r,n...t tGH572r tin ra^:niIr _ _ _Idrl 1 2C' ot7812 - a il� - _�a;a^ -n, SC - ,a;,n __ �r,.,..e'ap0;i it„tr sm f-"✓;1t ,•1,,,,o N-PSo d9 LrrpY -�fL 3:6 N i, ,,c. _�l*.:G•.-0Ca , -' c Thr C-i•Fxr�. ar _ rux:+�^-f�C v,� _ r„=;e, ,._.. �� , n. . e,.0 V„ .,, .,s ar;.,,-, ,.. .� ,-i-a'�«.>.,,.cte” t • t M1 t Version#63.S-TBD ,p,-s®lar0 '� PIL Y HARDWARE DESIGN AND STRUCTURAL ANALYSES RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1 64" 24" 39" NA Staggered 54.4% Portrait Hardware-Portrait Modules"Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1 48" 20" 65" NA Staggered 67.8% Structure Mounting Plane Framing Qualification Results Type Spacing Pitch Member Evaluation Results MP1 Vaulted Ceding 16"O.C. 370 Member Analysis OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing Information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. 3055 Clean.Way San 1`4ateo,CA 94402 1(550)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com 78F,.rCG1 ..GC'r- nr,/i�- :!ELi3C ..:o•,�.7-C' ^1 -:',Z r t,a.C!,X572, U +U SJrrl, '� !i ;H+iS at... •�aE��Il.'1•` ;•r,E.'1d137rE•, Ell.?]v7 Get i• !,L: Ap7;ac'.F, 1i,Iv1: PA U7P c95 "`�';ELCi:r 'Jdr-El- .',S:,t}- .c:].•°: ..fE r'i,r r^'C `.r. - - ,.ai'c::_/t21�_ T1JYri'r�,�n; 6�at ,y�,,d- a-.t a! :tc _ '-1711 :'R':IJ j1 'a;(Cf,C, -'1. R1i:lU R.C..1M., r,t•G JF �Irr,lrVrr,r "'JL+,.•,-v C:. sF''r+J.Jt __iJf,-r qf'nr n4 +CAtlf ,_.r_ ,.__ a,.,kd7•_.,�1 a.Ct,=rr .c, �'y_^ +rte, :.]221+C Ca^ I.—1, -_---41 L— .r-_,,1"3.11-0 }:vL�_ .,..._..�v:_C3'ri�t i� �r+7G .i.`,tC,iF� �::C:_-01'^7L 1 M t} STRUCTURE ANALYSIS,:,LOADING SUMMARY AND.MEMBER,CHECK,. MP1' Member Properties Summary An Horizontal Member,Spans °' Rafter.PrO erties Overhang 1.16 ft Actual W 1.50" Roof SyA0nfPwpernes. San•S '°' 16.18 ft Actual D Number of Spans w o Overhang) 1 San 2 Nominal Yes Roofin HMateriai., Com `Roof _ S'an_3 A, in-2 13`:88 Re-Roof No San 4 Sx(in A3) 21.39 Pf ood`Sheathing Yes' "':`S an'5 Ix in!`4 ;98:93° Board Sheathing None Total Rake Span 21.71 ft TL Defl'n Limit 180 �/aulted'Ceiling t` Y•esf PV 1'Start v 1°:50 ft '-:Wood'Species :SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 14.75 ft Wood Grade #2 Rafter.Slope 37° PV;2,Stmt' ' `Fb( si)`° 875 Rafter Spacing 16"O.C. PV 2 End Fv(psi) 135 Top Lat'Bracing;' "Full . PV 3 Start ; E(OW . "1',400'000 Bot Lat Bracing Full PV 3 End E-min(psi) 510,000 MembdetoadifiOuinniary= " ARoof Pitch° ' ' '9/12 Initial ,Pitch Adjust, NonzPV Areas PV Areas-° Roof Dead Load DL 14.0 psf x 1.25 17.5 psf 17.5 psf PV,DeadLoad-- PV-DL,' ` 3:0. sf x 1:25 Roof Live Load RLL 20.0 psf x 0.75 15.0 Psf Live%Snow,Loadt LL/3L''°i,Z 20.0 psf' ' x'0.7- ,;� x 0.39 14.0 PS,T 7,8,psf Total Load (Governing—LC) TL 31.5 psf 29.1 psf Notes: 1. ps=Cs*pf,Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(C)(IS)pg; Ce=0.9,Ct=1.1,L=1-0 Member Desi n Summa er NDS ;Governin` Load'Comb :CD,, CL" + CL" - �'CF'„ Cr ' D.+S. 1.15 1.00 . 1.00 1.1 1.15 "Member Anal Lsis Results`Summa ;Governin 'Analysis Ma'z-Moment' @-Location.-r Ca aci DCR';>r ' ° Result + Bending Stress(psi) 703 9.3 ft 1,273 0.55 Pass 1 r i CALCULATION OF-DESIGN WIND LOADS- MP1 - - - Mounting Plane Information Roofing Material Comp Roof Roof Slope _ _ .__ _ _ - __- _ ___. _- 370 Rafter Spacing 16"O.C. Framing Type/_Direction Y-Y Rafters PV System Type _ _ _ -w_ __ SolarCity SleekMountTm ZepSystemType - --- --._.__. --_--____-- -. -_.- _ -_-- ZSComP---.__.___. Standoff Attachment Hardware Como Mount Type C Spanning_Vents No Wind Desian Criteria Wind Design Code IBC 2015 ASCE 7-10 Wind Design-Method ___ _-_ _ _ _ Partial /Full Enclosed Method_ Ultimate Wind Speed V_Ult 135 mph - Fig_1609A Expooss urea -_ ---- -- -- - - - -- Cate99rY- . -C Section 26.7_ _ .__._ ..�__ __.. . _._ Roof Style - - -- - -- - - Gable Roof - Fig.30.4-2A/B/C-5A/B Mean Roof Height h 25 ft Section 26.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 30.3-1 - - -- -- - -- - --- ---- -- --- -- -- - ----- ------- ---- --- - - -- --- -------- ------- Topographic Factor _..___. -._. . _ _Krt_. . 1.00 Section 26.8 - - Wind Directionality Factor_ Kd 0.85 Section 26.6-1 Importance Factor I NA Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2) Equation 30.3-1 37.5 psf Wind Pressure Ext. Pressure Coefficient U GCp(Up) -0.95 Fig.30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down GC (Down) 0.88 Fig.30.4-2A/B/C-5A/B Design Wind Pressure p p= qh (GCp) Equation 30.4-1 Wind Pressure Up P(UP) -35.6 psf Wind Pressure Down 32.8 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable StandoffSpacing Landscape 64" _ 39" Max Allowable Cantilever___-.___ -____ -_-_Landscape­_ Standoff Confi uration Landscape Staggered Max-Standoff Tributary Area_ ___. _ Trib . _ ___ _.- 17 sf PV Assembly Dead Load W-PV 3.0 psf Net-Wind Uplift at Standoff T-actual _ _ _ _-346 lbs Uplift Capacity of Standoff T-allow 637 lbs_ Standoff Demand/&6a4y DCR 54.4% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered Max Standoff Tributa_ry.Area_ _ _ _ Trib _ _ _ _ __ 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff _ -T-actual _ _ -432 lbs - - ------ — - - ---- -- -- - - -- -- Uplift Capacityof Standoff T-allow 637 lbs Standoff Demand Ca aci DCR 67.8% ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET -- - PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 THREE LINE DIAGRAM LICENSE GENERAL NOTES Cutsheets Attached 1. ALL WORK SHALL COMPLY WITH THE 2015 IBC I AND 2015 IRC 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE. �tl •< x MODULE GROUNDING METHOD: ZEP SOLAR E COMMENTS AHJ: Southold Town REV BY DAT REV A RM 9/28/16 CUSTOMER REQUESTED UPSIZE • : + s s UTILITY: PSE&G—Long Island (Public Service Electric &-Gas Co.) • • • _ , _ _ CONFIDENTIAL—THE INFORMATION HEREIN JOB NUMBEJ B-1191390 00 PRASE OWNER: DESCRIPTION: DESIGN: R: ■ CONTAINED MALL NOT BE USED FOR THE ROBERT COCHRAN Robert Cochran RESIDENCE Bobby Morsch I,`�Olar•�l�" BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING Sym: 'AA ® NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 65 GARDEN CT 6.36 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MoOuiEs SOUTHOLD NY 11971 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (24) TRINA SOLAR # TSM-265PDO5.18 SHEET: REV: DATE; San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN �� PAGE NAME: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. Delta Solivia 5.2 TL COVER SHEET PV 1 a 9/28/2016 (666)—soL—CITY(265-2489)www.solamityeom ` PITCH:37 ARRAY PITCH:37 MPI AZIMUTH:148 ARRAY AZIMUTH: 148 MATERIAL:Comp Shingle STORY: 2 Stories of NE K zAcy�o COp� r � n Ij !, W O V 130 0•,,,31�15 A��FESSIONP� 1'-6" FSB LEGEND 9 8I I Q (E) UTILITY METER & WARNING LABEL --- INVERTER W/ INTEGRATED DC DISCO U— ,IAV I & WARNING LABELS `Y' �0' DC DISCONNECT & WARNING LABELS RSD --- L _ © AC DISCONNECT & WARNING LABELS RSD , D ; M Q DC JUNCTION/COMBINER BOX & LABELS a MP1 Q DISTRIBUTION PANEL & LABELS A Lc LOAD CENTER & WARNING LABELS O DEDICATED PV SYSTEM METER Front Of House Rso(E) DRIVEWAY RAPID SHUTDOWN Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR oo— CONDUIT RUN ON INTERIOR 65 Garden Ct GATE/FENCE Q HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L_�J SITE PLAN N Scale: 1/8" = 1' 01' 8' 16' F III CREW J B-1191390 0 0 PREMIA OWNER DESCRIPTION: DESIGN: CONFIDENTIAL-THE INFORMATION HEREIN JOB LAUNDER: \\,!a�OI���'�` , CONTAINED MALL NOT BE USED FOR THE ROBERT COCHRAN Robert Cochran RESIDENCE Bobby Morsch �_ ; Y BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSIEM: A at NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type c 65 GARDEN CT 6.36 KW PV ARRAY ��� PART TO OTHERS OUTSIDE THE RECIPIENTS MoouLEs SOUTHOLD NY 11971 ORGANIZATION,EXCEPT IN CONNECTION WITH 3055 ClewAew Way THE SALE AND USE OF THE RESPECTIVE (24) TRINA SOLAR # TSM-265PDO5.18 PACE NAME SHEEL RETE DATE San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1026 F:(650)638-1029 PERMISSION OF SGLAROTY INC. Delta Solivia 5.2 1L SITE PLAN PV 2 a 9/28/2016 (688)-SOL-arY'(765-2489)www.solarcityaam (E) 2x8 r OF NEIN �� I �K. Zq O C,y�,p� - z 1365 ,o, 136 S1 ' 16'-2" (E) LBW A SIDE VIEW OF MP1 NTS MPJ X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" STAGGERED PORTRAIT 48" 20" PV MODULE RAFTER 2x10 @ 16"OC ROOF AZ 148 PITCH 37 STORIES: 2 5/16- BOLT WITH INSTALLATION ORDER ARRAY AZI 148 PITCH 37 / Comp Shingle FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WI ZEP COMP MOUNT C TH POLYURETHANE SEALANT, ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. (E) ROOF DECKING V (2) V INSTALL LAG BOLT WITH 5/16° DIA STAINLESS - (5) (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) - � (E) RAFTER STANDOFF , J B-1191390 0 0 PREMISE OWNER— DESCPoPTION: DESGN: CONFIDENTIAL—THE INFORMATION HEREIN JOB NUMBER: ■ CONTAINED SHALL NOT BE USED FOR THE ROBERT COCHRAN Robert Cochran RESIDENCE Bobby Morsch �:,;So�arCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM •. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 65 GARDEN CT 6.36 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MH>ov�s SOUTHOLD NY 11971 ORGANIZATION,EXCEPT IN CONNECTION WITH 3055 ClearAew Way THE SALE AND USE OF THE RESPECTIVE (24) TRINA SOLAR-# TSM-265PDO5.18 PAGE NAME SHEET: REV- DATE; San Mateo,CA 94402 SOLARCITY EQUIPMENT,WITHOUT THE WRITTEN INVERTER: L(650)638-1028 R(650)638-1029 PERMISSION OF SOLARCITY INC. Delta # Solivia 5.2 TL STRUCTURAL VIEWS PV 3 0 9/28/2016 (888)-SCI.-CITY(765-2489)www.adarcitycom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND N GEC TO E WATER PIPE AT Panel Number:NoMatch Inv 1: DC Ungrounded _ 4 ( ) � ( ) INV 1—(1)Delta # Solivia 5.2 TL LABEL' A, (2 )TRINA SOLAR ## TSM-265PD05.18 PANEL WITH IRREVERSIBLE CRIMP Meter Number:75 056 369 Inverter;520OW, 24OV, 97.5%, Zlgbee, PLC PV Module; 255W, 243.2W PTC, 60-Cell, 40MM,BIk Frm, MC4, ZEP, t000V Underground Service Entrance INV 2 Voc: 38.3 Vpmax: 30.8 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL Delta �E; 1(E)50A/2P MAIN CIRCUIT BREAKER Inverter 1 INDWRIA 5 Delta 4 1 150A/2P - DC+ " Solivia 5.2 TL DG MP 1: 1x12 (E) LOADS z4ov4- : r--------------------- ----------- EGc-----------------� L1 1.2I N 3 2 - 3OA/2P _EGG DC+ DC+ ---------------------------------- A r-------------- GEC ---TN Dc c- MP 1: IX12 eL GND __ EGC ---- --------------------- –––––––––––— G– –––-–––––––– -----� I I (1 Conduit Kit; 3/4'EMT 1 N I I - EGGGEC – Z Z G7 __– (jEV� TO 120/240V I SINGLE PHASE 1 t UTILITY SERVICE I 1 • 1 • 1 . 1 - EGC ON ROOF TO BE ROUTED WHERE NOT SUBJECT TO PHYSICAL DAMAGE. WHEN ROUTED SUBJECT TO PHYSICAL DAMAGE THE SIZE MUST BE INCREASED TO #6 SOLID BARE COPPER. Voc* = MAX VOC AT MIN TEMP OI (1)CUILER–HAMMER it'BR230 PV BACKFEED BREAKER /t, A (2)Delta Q Solivia D� Breaker. 30A 2P, 2 Spaces /1 Smart RSS Rapid Shutdown, 60OV, 20A, NEMA 4X, MC4 (I)AWG#10, THWN-2,Black (2)AWG#10, PV Wire, 60OV, Black Voc* =522.84VDC Isc =9.1 ADC (2)AWG#10,PV Wire, 600V, Black Voc* =522.84VDC Isc =9.1 ADC O W(I)AWG #10, THWN-2,Red O (1)AWG/6, Solid Bare Copper EGC Vmp =369.6 VDC Imp=&61 ADC O (1)AWG 06, Solid Bare Copper EGC Vmp =369.6 VDC Imp=8.61 ADC I:L(1)AWG#10, THWN-2,White NEUTRAL Vmp =240 VAC Imp=21.6 AAC (1)Conduit Kit: 3/4' EMT (1)AWG(i8,,1H,WN-2,Green EGC/GEC-(1)Conduit Kit;.3/4'EMT (2)AWG#10, PV Wire, 600V Black Voc* =522.84VDC Isc =9.1 ADC (2 AWG X10,PV Wire, 600V, Black Voc* =522.84VDC Isc=9.1 ADC ® (1)AWG 16,Solid Bare Capper EGC Vmp =369.6 VDC Imp=8.61 ADC O (1)AWG 66, Solid Bare Copper EGC Vmp =369.6 VDC Imp=8.61 ADC (1)Conduit Kit; 3/4' EMT ,,, , , , , JB-1 191390 0 0 PREMISE OWNER DIptIPnoN: DESIGN: CONFIDENTIAL–'ME INFORMATION USED HEREIN JOB NUMBER: „ So�afC�ty. CONTAINED SHALL NOT BE USED FOR THE ROBERT COCHRAN Robert Cochran RESIDENCE Bobby MorsclT NORBENEFIT OF SHALL IT BENDISCLOOSSED IINWHWHOLE OR ICITY N Mou M sYSTETrI: 65 GARDEN CT 6.36 KW PV ARRAY �” PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: SOUTHOLD, NY 11971 3055 clearview Way THE SALE AND USE OF THE RESPECTIVE (24) TRINA SOLAR # TSM-265PDO5.18 PACE NAME SHEET- REV. DATE San Mateo,CA 94402 SOLARCITY EQUIPMENT WITHOUT THE WRITTEN INVrRTR T:(650)638-1028 F:(650)638-1029 PERMISSION of SOLARCITY INC. Delta # Solivia 5.2 TL THREE LINE DIAGRAM PV 4 a 9/28/2016 (&Z)-SOL-CITY(765-2489)www.solardty.com Lel Location: WARNING:PHOTOVOCTAIG POWER SOURCE. ab ', Label Location: .• ;Per Code: ,Y WAINIf\ly.�+ '• WARNING !`ELECTRIC SHOCK Per Code: Per Code: 690.31.G.3 HAZARD�,� NEC � ELECTRIC SH'.00K HAZARD NEC • NEC DONyOsTOCHTERMINAL THE DG CONDUCTORS OF THIS .•- • • TERMINALS®N BOTH1LINE AND PHOTOVOLTAIC SYSTEM ARE • : USED WHEN PHOTOVOLTAIC DC L,OAD�SI©ES MAY`BEENERGI9ZED UNGROUNDED ANDINVERTERIS � � IN THE}®PEN P®S�ITION MAY BE ENERGIZED UNGROUNDED DISCONNECTCode: NEC .•0 Label • • •_ on: PHOTOVOLTAIC POINT OF • INTERCONNECTION Code: MAXIIv1UN1 POWER,_A WARNPer ING: ELECTRIC SHOCK POINT CURRENT(fmp) Per Code: HAZARD. DO NOT TOUCH NEC690.17.4; •• 0 MAXIMUM POWEp)- POINT VOLTAGE. Vm VNEC 690.53TERMINALS.:TERMINALS ON MAXINiUM SYSTEM BOTH THE LINE AND LOAD SIDE VOLTAGE(Voc)_V MAY BE ENERGIZED IN THE OPEN SHORT-CIRCUIT POSITION..FOR SERVICE CURRENT(Isc)_A DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC _ A OPERATING CURRENT MAXIMUM AC V Label • • OPERATING VOLTAGE - VVAR N I N G ' Per ..- NEC ELECTRIC SHOCK HAZARD • IFAGROUND FAULT'ISINDICATED NORMALLY GROUNDEDLabel L• • CONDUCTORS MAY BE CAUTION • UNGROUNDED AND ENERGIZED DUAL POWER SOURCEPer Code: SECOND SOURCE IS NEC690.64.13.4 PHOTOVOLTAIC SYSTEM Label • • WARNING ' Per Code: Label • . ELECTRICAL SHOCK HAZARD _ DO NOT TOUCH TERMINALS. 690.17(4) 'CA l T I O N • TERMfNALS ON BOTH LINE ANDPer Code: LOAD SJDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM 690.64.13.4•, : IN THE OPEN POSITION CIRCUIT IS BACKFED QC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • WARNING '• Per ..- INVERTER OUTPUT Label Location: NEC 690.64.13.7 CONNECTIONDisconnect PHOTOVOLTAIC AC • DO NOT RELOCATEAC DISCONNECTPer Code: THIS ODEV CERRENTConduit NEC •.0 :. . Distribution (DC): DC Disconnect (IC): Interior Run Conduit LabelInverter MAXRv1UM AC ` • OPERATING CURRENT A Load "• Per Meter (M): Utility MAXIMUM AC OPERATING VOLTAGE VNEC • ' • Pointof Interconnection / 1 1-• 1 T •1 1 1 71 /• 3055 Llearview San Mateo,CA 94402 1 1' 1 / T 1 1 •' 1• / La •- - I 1 1 1 1 •M 14 7 / i '7• \1 1 1 'ASolarCity I ®pSolar Next-Level PV Mounting Technology ',55olarGty ®pSolar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs `+ u U a. Leveling Foot P-roof' 6rouaid Zep IniptcCk,x.'{Nry rddcsMvmi� Part No 850-1172 -,.,_., r _........ Le-Ung Foot ? ETL listed to UL 467 Zep Comgatlble t ff Module a � p nE: ^' Zep Groove RooliAttachment Array Shirt _^= Comp Mount Part No.850-1382 Listed to UL 2582 Mounting Block Listed to UL 2703 'Description ZZZPV mounting solution for composition shingle roofs =i. Fq �� Works with all Zep Compatible Modules eOMPP� • Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Interlock Ground Zep V2 DC Wire Clip UL LISTED , Specifications Part No.850-1388 Paft No.850-1511 Part No.850-1448 Listed to UL2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed • Engineered for spans up to 72"and cantileverer u to 2s up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices s�, • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip,End Caps Part Nos 850.0113,850-1421, 50-1460, zepsolar.com zepsolar.com $67 s ed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product The end-user documentaton shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty The customer is solely , responsible for verifying the suitability of zepSolar's products for each use Specifications are subject to change without notice Patents and Apps zspats com responsible for verifying the suitability of ZepSolar's products for each use Specifications are subject to change without notice Patents and Apps zspats com Document#800-1890-001 Rev A Date last exported November 13,2015 2 23 PM Document#800-1890-001 Rev A Date last exported November 13,2015 2 23 PM i SofarCity j 6 = - - -- j SolarCity ;`_ i i r [ frtr,,�s (Tf-)e 3m0 , 3_a , 5.2 , e_6 kvv, 7-S k �ic9a ®pasting ®/®ltag� l�ang�= 35 -- 550®/ icica-` ®p0--rem timg -r4---nrlpC--raturo--- Rang_ -1 3 — 15S F: (-25 — 70 C-- - - l-ligl-i CFC Eician�y= 97.5®/® - lntagratE-acl AFC--I (Arc Fault Circuit lntoarrupti®n) NEMA 4>< plus Salt Mist C®rr4c)s6®n l:Ir®t4---cti®n >a.F - Natural C®n�sacti®r� C®®lir-�g .;�� , ®u.-al MPiI-F (5.21c / E5_56c / 7.61c ) r' C®mnP.-Ict anCB fig"twe,--igR-tt ,. UL 1 741 / IEEFEE I S47 / IEEE I S47_ 'l / CFEE C ListEa�cl /UL I6995(Type-- I / NEC 69®_ 'l I _ � 4 tri-, ]"'r•Y.���i� rNr iy� pit'''' � a - ®olta Solar 1r-�verters ®atasl��et for SolarCity INPUT (DC) Max_ System_Voltages _ _ - 600 V _ Nma oinl Voltage 380 Ope_rating Voltage Ranges - - - - _85 Full Pw oePPT r MRange _ 200 _,500 V - Max_ Usable Current 18.0 A 20.0 A _ _ -_ -� _ - - - Aper k v - 20 O MPP tree ar Max. Short Circuit Current @ STC ' _ _ 25.0 A per MPP tracker _ Max_ Allowable Imbalance Power 5000 W 5600 W Allowed DC Loading Ratio _,- DCInternal' 2 MPP Tracker 2 Total Input Strings - ®UTPUT (AC) Nominal Power 3000 W 3800 \/V- _ S20_O W _ _6660 W 7600 W Max. Continuous Power 3000 W @ 2O8 V/ ;, 3300 W @ 200'\// 5200 W @ 208 V/ 6600 W @ 208 V/ 6600 W @ 208 V/ 3000 W @ 240 V _ 3800 W_t✓ 240 V 5200 W @ 240 V - 6600 W @ 240 V - ,__. 7600 W @ 240 V_, Voltage Range - - - - - - - . _ 183 - 228 V_ @ 208 V/211a^- 264_ V_@ 240_V - -- _ Nonrenal Current 14.4 A @ 208 V/ 1 S_8 A @ 208 V/ 24.0 A @ 208 V/ 31.7 A @-208 V/ 31_7'A @ 208 V/ _1 2.5 A Gad" -240 V _ 1 5.8 A,@ 240 V- - _ _21_6 A @ 240•V ,_ _ 27.5_A @,240 V _ 31_7 A @ 240 V _ - �. - _ Nominal Frecluenqy _ _ 60_ Frequency Ranges _59.3 - 60-5 Hz Adjustable Frequency Ranges -- __ _. 57.0 Night Consumption < 1_5 W Total Harmonic Distortion @ Nominal Power 3% Power Factor @ Nominal Power - 0-Se Adjustable Power Factor Ranges - 0.851 - O.85c <50 db A Acourtic Noise Emission Im_ GENERAL SPECIFICATION Max. Efficiency 97.S'%_ -208�/ 97.5% @/ 240V CEC Efficiency _ @ - - _ _ - Operatin Temperature Range _ -13 158-F (-25---70-(_-) I derating above 122-F (50-C) Storage Temperature Range _ _ _ -40 --- 185-F,(740 - 8S-C) Humidity O ^- -100-/. - Max. Operating Altitude 200. Om above sea level MF_=C "ANICAL ®ESIGN _ . Size L x W x D i n ches (L x W x D m m) 1!9.5 x 1 5.8 x 8_S 1 n (-4:65 x .401 x 2 1 6 m m) 2 6.8 x 1 5.8 x 8.5.i n (6 8 0 is 401 x 21 6 m m) 65.0 lbs (29.5 kg) . Weight - -.r 43.0 lbs (19.5 kg) _ - _ - Natu'ral Convection AC Connectors _ Spring terminals in connection Compatible Wiring C3uage in AC _ AWG 12 -A_W__G_e Copper (A_ ccording to N_EC :310-IS _ DC Connectors 2 pairs of spring terminals in connection box _ 4 pairs of spring terminals in connection box Compatible Wiring C3uage in DC _ _ - -_ _AWG 12 - AWG 6 Copper (According to NEC 69.0.8 ) Communication Interface _ _ r Zig Bee Display 3 LEDs, 4-Line LC® Enclosures Matarial _ _ Deecast Aluminum STANDARDS / ®IRECTIVES Enclosure Protection Rating NEMA 4X, IEC 60068-2-11 Salt mist Safety UL 1741 Second Edition, CSA SW Approval UL 1998 Ground-Fault Protection _ NEC 690.35, UL 1741 CRD Anti-I .iandin9 Protection IEEE 1547, IEEE 1547.1 EMC FCC part 15 Class B , AFCI UL 16996 (Type 1), NEC 690.11 PV Rapid Shutdown UL 1741 CRD PVRSS, NEC_690.12 (with SMART R_-3_-S) _ Integrated Meter (--I 1 ( ANSI 2. nr eet 2% A cur Regulation of Grid Support RECO Compliant, IEEE1547 _ Standard Warranty _ _ _ _ - 1 O years ®alta Procluots Corlao rasion, Ino_ 46101 Fremont Blvd, Fremont, CA 94538 Sales Email_ inverter_salast�deltaww_com Support Email: inverter.support@deltaww.com Sales Hotline: -'-1-877-440-5851 or +1-626-369-8021 Support Hotline: Support (Intl_): Monday to Friday from 7 am to 0 pm PST (apart from Holidays) ILkcc� SIJ THE Tri amount MODULE TSM-PDOSA/P®05o18 Mono Multi Solutions DIMENSIONS OF PV MODULE ELECTRICAL DATA 0 STC i� unit:mm Peak Power Watts-PMA.(WP) 250 255 260 265 THnvmount 941Power Output Tolerance-PMAx(W) 0-+5) Maximum Power Voltage VMP(V) 30 3 30 5 30 6 308 NNRpNCe( ��, o Maximum Power Current—IMPP(A) 827 837 850 861 ANu_ .'n Open Circud Voltage-Voc(V) 380 381 382 383 ) ® - � 1 ^-09n1z Short Circuit Current-Ise(A) - &79 8 88 900 910 i Jf WSTALLPIG HOIE - % a Module Efficiency qm(%J 153 15.6 159 162 MODULEi ( STC Irradiance 1000 W/m',Cell Temperature 25'C,AV Mass AMl Saccordmgto EN 60904-3 ' Typical efficiency reduction of 4 59 at 200 W/m'according to EN 60904-I to �, to o i - ELECTRICAL DATA @ NOCT Maximum Power-P.Ax(Wp) ! 186 189 - 193 ! 197 • 0-CELL ,CELL Maximum Power Voltage-VMP(V) 28 1 28.2 28 4 r •28 6, MULTICRYSTALLINdEMDDULE Maximum Power Current-IMPP(A) 663 671 681 689 6043 GROUNDING HOLE I I A A IOpen Circuit Voltage(V)-Voc(V), " 353, 3 354- 355 ., WITH TRINAMOUNT FRAME 9 I ® G�"WHe� Short Circuit Current(A)-Isc(A), 710 717 '727 735 NOCT Irradiance at 800 W/m',Ambient Temperature 20°C,Wind Speed l m/s 812 780 -/e�1/�� _ PD05 10 PD05 18 255 265W MECHANICAL DATA � eack Vlew 4 ` Solar cells Mulficrysta[line 156 x 156 mm(6 inches),4BB € e POWER OUTPUT RANGE - d s•' '-'- 11 F Cell orientation ';6 .6 0 cells(6 x lO), • a,. - a E 1 Fast and simple to install through drop in mounting solution dimensions 650 x 992 x 40 mm(64 95 x 39.05 x 1 57 inches) ry - #Weight '19 6 kg(43 12lbs) - • . �® Glass `3 2 mm(0 13 inches),High Transmission,AR Coated Tempered Glass A i Backsheet White jMAXIMUM EFFICIENCY A_A Frame ;Sllver(PD0510),Black(PD0518)Anodized A[uminlum Alloy Good aesthetics for residential applications J-Box IP 65 or IP 67 rated ConnectorMC4 - t Cables i Photovoltaic Technology cable 4 0 mm'(0 006 inches'), 0-+SYN ) ^_ r 1200 mm(472inches) I-V CURVES OF PV MODULE(260W) " { : f' " POSITIVE POWER'TOLERANCE levo Fire Type U L 1703 Type 2 for Solar City " Highly uetostringentqualitycontrol __ H de ao - k;`DIPJ .) 0 Over 30 In-house tests(UV,TC,HF,and many more) � Roaw ,As a leading global manufacturer ° In-house testing goes well beyond certification requirements ` B00 6WW/,' TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic ° PID resistant E 6. products,we believe close ' I i, 4aa Nominal Operating Cell ,44°C(+2°C) OperahonalTemperature 40-+g5°C Temperature(NOCT) - cooperationwithourpartners 300 m Maximum System 1000VDC(IECJ' zaa eaw/' Temperature Coefficient of PNAx =0 41%/`C j z Voltage, X 1000V OC(UL) i is critical to success,With local --------- ""t presence,around the globe,Trina is 00 ~ Temperature Coefficient of Voc -0 32%/°C Max Series Fuse Rating 15A able to provide exceptional service aoa o ,6 zo so 4a so ('Temperature Coeffiaent of Isc ,A 05%/°C to each customer in each market �,' Certified to Withstand challenging environmental _.,e... _,_._a_ _- ._ ._..__w v.a-_.a and supplement our Innovative, $ conditions v°a�a.ln reliable products with the backing ° 2400 Pa wind load of Trina as a strong,bankable WARRANTY partner We are committed ° 5400 Pa snow load i p e10 year Product Workmanship Warranty to budCERTIFICATION ding strategic,mutually 25 year Linear"Power Warranty beneficial collaboration with (�'} t.. _.. installers,developers,distributors at (Pleaserefer to product warranty for details) and other partners as the tlr ! L�TEn ° backbone of our shared success In - drivingSmartEnergyTogether LINEAR PERFORMANCE WARRANTY PACKAGING CONFIGURATION o 10 Year Product Warranty°25 Year Linear Power Warranty COMPLIANT E6E Modules per box z6 pieces w' Trina Solar Limited oMPU -P-' . P "" 1 www tnnasolar coin _. o-. , t 4100% Modules per40'container 728 pieces _...u.'1 Acidiliosommmzr,ol a _< vogue r 0 90% 1 tiy3,,_Vry_< ,Y _ rOm rrihO SOlgry ligear Wq�gn� CAUTION READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT �oMvaT�e ° ' §` - ® m 2016Trina Solar Limited All rights reserved Specifications included in this dalasheet are subject to -aSOIOY O 80% '�-` - ,� _ :.�-.^ TD-owsolar change without notice 1.966 '-.4:`; .. - .,,•e�«.>i �n Smart Energy Together Years 's N to 15 20 20 25 Smart Energy Together p°nnra'�e _ -lillijinriastangard 'ncustryswndzrd Version#63.5-TBD solarCit . PIL October 4,2016 nD 1EC[E5'V[2 D RE: CERTIFICATION LETTER JAN 6 2017 Project/Job # 1191390 Project Address: Cochran Residence 65 Garden Ct BUMDI iG DEPT. Southold,NY 11971 TOWN OF SOU THOLD AHJ Southold Town SC Office Long Island Design Criteria: -Applicable Codes= 2016 Residential Code of NY State,ASCE 7-10,and 2012 NDS - Risk Category = II -Wind Speed = 135 mph,Exposure Category C -Ground Snow Load = 20 psf - MP1: 2x10 @ 16"OC,Roof DL= 14 psf, Roof LL/SL= 15 psf(Non-PV),Roof LL/SL= 7.8 psf(PV) Note: Per IBC 1613.1; Seismic check is not required because Ss= 0.19994< 0.4g and Seismic Design Category(SDC) = B< D To Whom It May Concern, A Iobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation,I certify that the existing structure directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. OF NEIN K. Z4 O� CO Paul Zacher, P.E. * �� Professional Engineer w T: 916.961.3960 x101 email: paul@pzse.com 91365 AR�FESSIONP 3055 Ciearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOI.-CITY F(650)638-1029 solarcity.com AL 055W.AR M-5937 Ai ROC 2437711ROC 2-5450,C1 CSLR IM0104 C0 ECtb041 GT HIC 06327:9/ELC 0925b05 OC 4}051=tiaffiOQOfECf'902EN5 DE 20n OWO TS-,tsM2,aL E=L(0 226 Iii CT-297'0,It 15-W52 h1A HC 1A5512/ EL-1.36MR MO NC 12694 P3 MAO-NC 1001-U NH 0S41C/12621M NJ NJNVCWib4TdOL tE0500/3d£t30773T7CA N•.I E£45-31969a INtvV2E-f,2n35172/C2-O0736tb7Ei2-Cx3397W,CH EL 41719'OA M20393/C562 PA`6CFAU7)&:3 R; A-004714/R,93H3T3-TX TECL270 6 UT 8726;50.5501 Jh ELE2,t05153218 VT EM-05329 kA SCLIWC•9590}I301ARC'9G5a'7 AL n 4337 Gt<-,a A-161 N—nw N230911000a Putnam AC604},R-I%nd H-1106.-40-00-00 Suttolr 52057-H Yleso$eOlsrWC-25f,,8-H}}h:YC 42U138a-DCA SCENIC'N Y Llosn—JO-W,Jtn 411241041004485150''ht f` oth F1 UrltT)5r-0m NY1,1201R2013946-DCA Pliioars yrcwar.-yL SaiarCtry FinarrcSQmaany LLC (A 9-141 ILantlershf--6r.EVW,SaSerCFiy Fnsnea Cnmpamr Ll Ctt lu -tIL,b,-DtAsw.,u Zht,r9an<CI.m,�,>E.ne,to anepSa 1ncw•.1rc:t ln0olauaro antler flG*'m.nunllwr 0+9422 1.;—,2241 NV ,n,ta'tel+nt L93n LI:*rn.a 1L}7023Itr 5}044 Fl Llcencatl L�',tler F10153103LL,T9 R•ei:tar.4 Ged14r L:0Ge1:,W03.20i40d,VT L,+n3r LSc.r 5n hL7ab Version#63.5-TBD �ga PIL 6.5olarCit . y HARDWARE DESIGN AND STRUCTURAL-ANALYSIS RESULTS:SUMMARY TABLES' Landscape Hardware-Landscape Modules'Standoff'Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPI 64" 24" 39" NA Staggered 54.4% ;PortraitHardware---Portrait,Modules'Standoff Specifications X' 'Hardware X- Spacing° 4 , X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPI 48" 20" 65" NA Staggered 67.8% 3.-Structure Mounting-Plane-Framing Qualification Results Type Spacing Pitch' Member Evaluation Results MP1 Vaulted Ceding 16"O.C. 370 Member Analysis OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing Information gathered on site.The ewstmg gravity and lateral load carrying members were evaluated In accordance with the IBC and the IEBC. 3055 Clearview Way San Mateo,CA 94402 T(650)638-102 8 (888)SOL-CITY F(650)638-1029 solarcity.com At 05507,AR ht-8937.AZ RCC 243711/800 245450 CA CSLB 6138104 CO EC8041 CT}IIC 0632178JUC 012L30L DC 410'1 100JCi30/ECM2585 DE 20A120<WW TI.6032.FL EC13006226 Pit CT-29770,IL 1,0052,MA HIC 169W2/ EL-1,34M R PSD WC 12VM'111105 NC3O801-1J NFI O'WC11252313SaJNJMC#l3VH0616J?'30/34EB017327CV NM EE98-379500 t7J412012135172/02-0078648/82-0079719.0H EL 47707 OR r5100498!C562 PA IIICPA077343 R) ACW47U/RgL8313 TXTECL27006 188726950-5501 VAELE2705153278 V7EM-0S829-VJASOLPRC'9100'✓SOLARC'905P7 AJbzrry139 G­­A-48Nassau H2409710000 Puna,.PC6041 Rockland H-11864-40-00-00 Suffolk 52057-1-1 d'euCPMtI040-26'"8-HR NYC#2)184-DCASCENYC NYC Llco,,rd ElocLldan#12610-0004485155Wate SL 6tnA Un,M Br tiyn.NY1/201n20J3S66-0CA AJIleanspro�,d-dby SotaCsty Finance Company LLC CAF,o ce Lenders Ulc o6G54706 So10rC1ty Finance Compny LLC"licensed Lf In.Ddawaro S tate Ban),Cammsssioner to enrage in busfn?as In Delowm?under licensa numb-,019422 NY 6naiafhnant Ltanticans?IL14?23IIL7702A P�Lkensad Londa#2053103LL,TX R,ei,t-1 Cradl tar 140.i06OW-202404 VTLandsLic- k67o6 STRUCTURE ANALYSIS- LOADING SUMMARY AND MEMBER CHECK- j! 1 . Member Properties Summary MPI Horizontal Member Spans Rafter Pro erties - Overhang 1.16 ft Actual W 1.50" Roofs stem Proerties _,'"Span 1 ',16.'18 ft Actual',D, 9.25!'_:z,:' Number of Spans(w/o Overhang) i San 2 Nominal Yes Roofing Material ' Comp Roof -S an 3' Ain^2 13.88 Re-Roof No Span 4 Sx(in A3) 21.39 PI" ood,'Sheathing'• Yes W'S an S Ix in^4 98.93,, Board Sheathing None Total Rake Span 21.71 ft TL Defl'n Limit 180 Vaulted Ceilin Yes ;PV 1 Start 1.50 ft' Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 14.75 ft Wood Grade #2 Rafter'Slo 3Z° PV 2 Start,: Fb(psi 875" e° Rafter S acin 16"O.C. PV 2 End Fv(psi) 135 ITop Lat Bracing Full PV 3 Start E(psi) . .,,1400,000 Bot Lat Bracing Full PV 3 End E-min(psi) 510.000 Member Loading Summary Roof Pitch 9/12 Initial _ Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 14.0 psfx 1.25 17.5 psf 17.5 psf PV Dead Load PV-DL" 3.0 sf.", x ,1.25 3.8 'Sf. " Roof Live Load RLL 20.0 psf x 0.75 15.0 Psf Live/Snow Load. LL/SL =20.0 psf.- x OJ` f 0.39 14.0'psf 7.8'psf Total Load,(Goverhingi LC TL 31.5.psf 29.1 sf Notes; 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(CJ(IS)pg; Ce=0.9,Ct=1.1,I5=1.0 Member Design Summa (per NDS Governing Load Comb CD - CL + CL - CF Cr D+ S 1.15 1.00 1.00 1.1` 1.15 ` Member Anal'sis Results Summiary Governing Analysis Max Moment @ Location Ca aci DCR Result + Bending Stress(psi) 703 9.3 ft 1,273 0.55 Pass �CALCULATIONOF4DESIGIVWIND LOADS=MP1 T� ' Mounting Plane Information Roofing Material. "° Comp Roof "< Roof Slope 370 RafterSpacing 16"O.C. - Framing Type/Direction Y-Y Rafters PV System Type_�r __a^ - r __ _ " SolarCity SleekMountT"" Zep_System_TypeZS Comp _ Standoff Attachment Hardware' _ °`Como MountF7voe C Spanning Vents No Wind Design Criteria ' Wind Design Code _ IBC 2015 _ ASCE 7-10 Wind Design Method„ Ultimate Wind Speed V,Ult 135 mph Fig. 1609A Exposure Category__,____. _ _ _. �. _ m _ _. _ _ _ _Section 26.7 Roof Style_ 4ht fi Gable Roof Fig.3_0.4-2A/B/C-5A/B Me Roof Hei _- Po25'ft' Section 26.2 Wind Pressure Calculation Coefficients ' Wind Pressure Exposure KZ _ 0.95 Table 30.3-1 Topographic faqor. _4 .. = Krt:. . , .__w_.. _ -_ 1.00 4 __... _._._.. �.__. _Section 26.8 Wind Directionality FactorKd 0.85 Section 26.6-1� Imoortance`Factbr}� ___.. _.-. �.. . . -._ Velocity Pressure qh qh =0.00256(Kz)(Kzt)(Kd)(V^2) Equation 30.3-1 37.5 psf Wind Pressure. Ext. Pressure Coefficient U GCp(Up) -0.95 Fig.30.4-2A/B/C-5A/B Ext.-Pressure Coefficient Down GC Down -0.,88 Fig.30.4-2A/B/C-5A/B Design Wind Pressure p p=qh(GCp) Equation 30.4-1 Wind Pressure Up p„ -35.6 psf Wind Pressure Down 32.8 psf ALLOWABLE STANDOFF SPA_CINGS���_: ___ X-Direction Y-Direction Max Allowable Standoff Spacing Landscape64" 39" Standoff Configuration Landscape Sta eyed MaxµStandoff Tri6uta,ry.Area, .. W-_.. .. ;.Trib. _.>..,._, W _.,.„.. _... ._ _._.._..._,. 17 sf i.,.w.... .w, , wµ..-,., - _ .....,. .,_ .,.,.. PV Assembly Dead Load_ W-PVA _ 3.0 psf Net Wind Uplift at Standoff__ _Uplift Capacity of Standoff T-allow 637 lbs Standoff Demand Ca aci DCR ° :4%° X-Direction Y-Direction Max Allowable Standoff Spacing_ Portrait _ 48" 65" Max Allowable,Cantileverw, Standoff Configuration Portrait StaQqered Max Standoff Tribufa_ry Area 22 sf - PV 3.0 psf Net Wind Uplift at Standoff ._m __—T-actual Uplift_Capacity_of StandoffT-allow 637 lbs Standoff Demand Ca aci _ DCRIT_. _. _ 67.8% w _.� ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTER11ED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, ® FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. D GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MUL11WIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. JAN 6 2017 I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL - Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(8). � � �DEPT. Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC"RACEWAYS OR TOWN OF SOUTHOLD kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD 'BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT VOLTAGE AT MAX V cp VOLTAGE AT 0 ENPOWER CIIRCUIT VICINITY MAP . INDEX W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 THREE- LINE DIAGRAM LICENSE GENERAL NOTES Cutsheets Attached 1. ALL WORK SHALL COMPLY WITH THE 2015 IBC AND 2015 IRC ' 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR ` t 4 AHJ: Southold Town . REV BY DATE COMMENTS REV A RM 9/28/16 CUSTOMER REQUESTED UPSIZE REV B RM 10/24/16 ADDED ONE MODULE UTILITY: PSE&G—Long Island (Public Service Electric CONFIDENTIAL— THE INFORMATIONHEREIN ISOLAREDGE OB NUMBER: PREMISE OWNER DESCRIPTION: DESIGN:. CONTAINED SHALL NOT BE USED FOR THE JB-1191390 00 ROBERT COCHRAN Robert Cochran RESIDENCE Bobby'Morsch • BENEFIT OF ANYONE EXCEPT SOLARCITY INC., OUNTING SYSTEM: �d SolarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR INComp Mount Type C 65 GARDEN CT 6.25 KW PV ARRAY ►,, PART TO OTHERS OUTSIDE THE RECIPIENTS ODDLES S O U TH O LD N Y 119 71 ORGANIZATION, EXCEPT IN CONNECTION WITH , THE SALE AND USE OF THE RESPECTIVE (25) CANADIAN SOLAR # CS6P-250PX 3055 Clearview way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER.- PACE NAME: SHEEP REV: DATE San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. PV 1 b 10/24/2016 T:(650)638-1028 F:(650)638-1029 SE6000A-US-ZB-U COVER SHEET (888)—SCI.—CITY(765-2489)www.solarcity.com PITCH: 37 ARRAY PITCH:37 MP1 AZIMUTH:148 ARRAY AZIMUTH: 148 MATERIAL:Comp Shingle STORY. 2 Stories OF NEVy K Zq y000 � n !i W - Q � 91365 AR�FESSIONP�. -- l'-6" FSB -- ---- - I -i - - -- I - LEGEND I I Q (E) UTILITY METER & WARNING LABEL �w-` lay INVERTER W/ INTEGRATED DC DISCO �I iV & WARNING LABELS M I © DC DISCONNECT & WARNING LABELS I I © AC DISCONNECT & WARNING LABELS MP1 D,; M Q DC JUNCTION/COMBINER BOX & LABELS Q DISTRIBUTION PANEL & LABELS A ❑ � LOAD CENTER & WARNING LABELS O DEDICATED PV SYSTEM METER Front Of House RSD RAPID SHUTDOWN (E) DRIVEWAY Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR ©o© CONDUIT RUN ON INTERIOR 65 Garden Ct — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED I� 'I INTERIOR EQUIPMENT IS DASHED L_"J SITE PLAN Scale: 1/8" = 1' 01' 8' 16' F J B-11913 9 0 D O PREMISE OYMER. DESCRIPTION: DESIGN; CONTAINED AL— THE INFORMATION USED HEREIN a0e NUMBER: ROBERT COCHRAN Robert Cochran RESIDENCEBENBobby Morsch SolarCit CONTAINED SHALL NOT E USED FOR THE NOR SH LL ANYONE EXCEPT SOLMOLE INC., MOUNTING SYSTEM: 65 GARDEN CT NOR SHALL IT BE DISCLOSED IN WHOLE T' IN Comp Mount Type C 6.25 KW PV ARRAY r�� PART TO OTHERS WTSIDE THE RECIPIENT'S I,1` y. ORGANIZATION,EXCEPT IN CONNECTION WITH MODULES: SOUTHOLD, NY 11971 THE SALE AND USE OF THE RESPECTIVE (25) CANADIAN SOLAR # CS6P-250PX 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: -PAGE NAME SHEET: REV: DATE San Mateo, CA 94402 PERMISSION OF soLARarr INC. SOLAREDGE SE6000A-US-ZB-u SITE PLAN PV 2 b 10/24/2016 )-SOL) CITY(7 5 F89)w 838-1029 (888)—SOL—CITY(765-2489)www.soiarcityaam t " v� (E) 2x8 S1 OF NEI�y I K zAtiF0 C 16'-2" r W � (E) LBW 13651K18�� A SIDE VIEW OF MP1 NTS AROFESSIONP� MPJ X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" STAGGERED PORTRAIT 48" 20" - PV MODULE RAFTER 2x10 @ 16"OC ROOF AZI ARRAY AZI 148 PITCH 3i PITCH STORIES: 2 5/16" BOLT WITH INSTALLATION ORDER Comp Shingle FENDER WASHERS LOCATE RAFTER, MARK, HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL-PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH ZEP COMP MOUNT C POLYURETHANE SEALANT. ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (1) (4) PLACE MOUNT. (E) ROOF DECKING V (2) V INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) • (E) RAFTER - STANDOFF Scale: 1 1/2" = 1' • CONFIDENTIAL—JHE INFORMATION HEREIN A NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE J B-11913 9 0 0 0 \\�!� ROBERT COCHRAN Robert Cochran RESIDENCE BENEFIT OF ANYONE EXCEPT SOLARCITY INC..' MOUNTING SYSTEM Bobby Morscn SolarCity. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S Comp Mount Type C 65 GARDEN CT 6.25 KW PV ARRAY 'iv� ORGANIZATION, EXCEPT IN'CONNECTION WITH MOOuUm_ SOUTHOLD, NY 11971 THE SALE AND USE OF THE RESPECTIVE (25) CANADIAN SOLAR # CS6P-250PX sols t e,CAW way SOLARCITY EQUIPMENT, VATHOUT THE WRITTEN PAGE NAME SHEET: REY: DATE 63 Mateo F. 94402 PERMISSION OF SOLARCITY INC. INVERTER: � T:(650)638-1028 F:(650)638-1029. SOLAREDGE SE6000A—US—ZB—U STRUCTURAL VIEWS PV 3' b 10/24/2016 ' (888)-SOL-CITY(765-2489)www.sdardtycom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE GOND (N) #8 GEC TO (E) WATER PIPE AT Panel Number:NoMatch Inv 1: DC Ungrounded INV 1—(1)SOLAREDGE #SE6000A—US—ZB—U LABEL: A —(5)CANADIAN SOLAR # CS6P-250PX PANEL WITH IRREVERSIBLE CRIMP Meter Number:75 056 369 Inverter; 6000W, 24OV, 97.57d, w/Unifed Disco and ZB, AFCI PV Module; 250w, 229.6W PTC, 40mm, Black Frame, MC4, ZEP Enabled Underground Service Entrance INV 2 Voc: 37,2 Vpmax: 30.1 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 150A/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING 150A/2P 3 SOLAREDGE A 1Dc+ - - - -- I SE6000A—US—ZB—U D0- MP 1: 1x13 I I l� (E) LOADSL, zaav ----- ---------------- ------------ � EGC--------------— ---j • t • Dc* I N DG- 1 2 35A/2P —Ecci Dc+ + A ------------------------------------------------ GEC ---� DG GC— c MP 1: 1x12 6 I ----------j - I GND E -- --------------------- ------------- G I I (1)Conduit Kit; 31e EMT N I t I EGC/GEC —� Z Z - C7 GEC�� " TO 120/240V SINGLE PHASE UTILITY SERVICE I I I I EGC ON ROOF TO BE ROUTED WHERE NOT SUBJECT TO PHYSICAL DAMAGE. WHEN ROUTED SUBJECT TO PHYSICAL DAMAGE THE SIZE MUST BE INCREASED TO #6 SOLID BARE COPPER. Voc* TT= MAX VOC AT MIN TEMP Ol (1)Breaakker,H 35A 2P, 2 SpacesPV BACKfTfD BREAKER a PV ` (25)SOLAREDGE 1!P300-5NM4ZS D� PowerBox ptimizer,300W, ZEP, in MC4,out MC4 (1)AWG#8, THWN-2, Black (2)AWG#10,PV Wire, 60OV, Black Voc* =500 VDC Isc =15 ADC O L (1)AWG p8, THWN-2,Red O (1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=9.16 ADC (I)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=25 AAC (1 Conduit Kit,• 3/4'EMT —(1)AWG#8, THWN-2, Green EGC/GEC—(1)Conduit Kit; 3/4"EMT (2 AWG#10,PV Wire, 60OV, Black Voc* =500 VDC Isc =15 ADC O (I AWG#,6, Solid Bare Copper EGC Vmp =350 VDC Imp=8.46 ADC (11)Conduit Kit;.3/4'EMT CONFIDENTIAL— THE INFORMATION HEREIN JOB NUM : PREMISE OWNER. DES3UP110N DESIGN: BER CONTAINED SHALL NOT BE USED FOR THE JB-1 191390 0 0 \\�ea w ROBERT COCHRAN Robert Cochran RESIDENCE Bobby Morsch 'JA SOIarClty BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ����� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type c 65 GARDEN CT 6.25 KW PV ARRAY A01 PART IZ OTHERS OUTSIDE THE RECIPIENT'S MODULES: SOUTHOLD NY 11971 ORGANIZATION, EXCEPT IN CONNECTION WITH � THE SALE AND USE OF THE RESPECTIVE (25) CANADIAN SOLAR # CS6P-250PX 3055 Cleariew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE San Mateo,CA 94402 PERMISSION of SOLARCITY INC. INVMTER. SOLAREDGE SE6000A—US—ZB—U THREE LINE DIAGRAM PV 4 b 10/24/2016 (888j sa�cHT38Y(7655-2489)www�ialrcitycom WARNING:PHOTOVOLTAIC POWER SOURCE Label • • s k "• • Label • ' wPer Code: . WARNING ;_ WARNING r Code: Per •._ •` ELECTRIC SHOCK-HAZARD ';��` ELECTRIC SHOCK HAZARD NEC '• DO NOT TOUCH'TERMINALS 690.17.E NEC THE DC CONDUCTORS QF THIS '• Label Location: tTERMINQCS ON B,QTH LINE AND PHOTOVOLTAIC SYSTEM ARE • BE USED WHEN L'QAD SIDES MAYBE ENERGIZED i UNGROUNDED ANDINVERTERIS PHOTOVOLTAIC DC IN THE OPENPOSITION - MAY BE ENERGIZED DISCONNECT UNGROUNDED NEC •.0 Label Label Location: PHOTOVOLTAIC POINT OF -• MAXINIUM POWER-_ • INTERCONNECTION _ Code: Per POINT CURRENT(Imp} A WARNING; ELECTRIC'SHOCK Code: HAZARD. DO NOT TOUCH NEC 690.17.4; NEC 690.54 MAXINIUM POWEp)_VNEC 690.53 TERMINALS.TERMINALS,ON POINT VOLTAGE Vm BOTH THE LINE AND LOAD SIDE MAXINIUM SYSTEM �� MAY BE ENERGIZED IN THE OPEN VOLTAGE(Voc) POSITION:FOR SERVICE SHORT-CIRCUIT A DE-ENERGIZE BOTH SOURCE CURRENT(Isc)_ AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC _ A OPERATING CURRENT MAXIMUM AC V •-I Location: OPERATING VOLTAGE _ WARNING ' Per ..- ELECTRIC SHOCK HAZARD 690.5(C) IF A GROUND FAULT IS INDICATED NORMALLY GROUNDEDLabel L• • CONDUCTORS MAY BE MA,UTION • UNGROUNDED AND ENERGIZED ••-NEC •. •, :OLTAfC SYSTEM Label • • WARNLNG ' Per Code: Label Location: ELECTRICAL SHOCK HAZARD _ DO NOT TOUCH TERMINALS 690.17(4) 'CAUTION • TERMI°NALS ON BOTH LINE ANDPer Code: LOAD SIDES MAY BE ENERGIZED PHDTOVOLTAIC'SYSTEM IN THE OPEN POSITION CIRCUIT IS BACKFEDNEC 690.64.13.4•' • ' ' DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • Per WARNING Code: INVERTER OUTPUT Label • • CONNECTION 690.64.13.7 PHOTOVOLTAIC AC • DO NOT RELOCATEDisconnect DISCONNECT •• THIS ODEV CERRENT (C): Conduit NEC .•0 :. (D): Distribution Panel (DC): DC Disconnect onduit Label' (INV): Inverter With Integrated MAXINIUM AC A �• •"• OPERATING CURRENTDC Disconnect •• Meterenter(M): Utility NEC MAXINIUM AC • 90.54 (P01): Point of Interconnection OPERATING'VOLTAGE V 1 la /'' 1 a• 1 - I 1 11 55 aearview Way San Mateo,CA 94402 a. , 1'1 1' til •- - 29 MAXr • 1 1 1 1 7' 1128 111 1 a / a •a• \N1 • ' w 0 olarCity ZepSoLar Next-Level PV Mounting Technology 1�,-6olarCity ZepSoLar Next-Level PV Mounting Technology Components , Zep System for composition shingle roofs U Leveling Foot Interlock Ground Zep Part No 850-1172 Leveling Foot ETL listed to UL 467 S" �Z FMtUp Compatible FV Module Roof Attachment Array Writ Comp Mount Part No.850-1382 Listed to UL 2582 Mounting Block Listed to UL 2703 .ol4PAr, Description IPV mounting solution for composition shingle roofs Works with all Zap Compatible Modules 06APOP Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Interlock Ground Zep V2 - DC Wire Clip UL LISTED Specifications Part No.850-1388 Part No.850-1511 Part No 850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zap System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wife management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip,End Caps Part Nos.850-0113,850-1421, 850-1460,850-1467 zepsolar.com zepsolar.com Listed to UL 1565 This document does not create any express warranty by Zap Solar or about its products or services.Zap Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zap Solar or about its products or services Zap Solar's sole warranty!s contained in the written product warranty for each product.The end-user documentation shipped with Zap Solar's products constitutes the sole specifications referred to in the product warranty The'customer is solely each product The end-user documentation shipped with Zap Solar's products constitutes the sole specifications referred to in the product warranty The customer is solely responsible for verifying the suitability of ZepSolar's products for each use Specifications are subject to change without notice Patents and Apps zspats com responsible for verifying the suitability of ZepSolar's products for each use Specifications are subject to change without notice.Patents and Apps zspats com Document#800-1890-001 Rev A Data last exported November 13,2015223PM Document#800-1890-001 Rev A Date last exported November 13,20152 23 PM le �.d�► pesiPnr �� CS'6P-'23.5/240"/245/25;0/25'5PX' �} X1�' ughFta�e „ " ®it' CarladianS®lar E r Black=framed Electrical Data ' ,1,• _. _ " *'teak;� r° -STC1- - - - CS6P-235P CS6P-2V40OXCS6CS6P-250P'CS6P-255PX Temperature Characteristics Nominal Maximum Power(Pmax) 235W 240250W 255WOptimum Operating Voltage(Vmp) 29 8V 29 930 1V 30 2V Pmax -0.43%/°C. . -, Optimum Operating Current(Imp) 7 90A 8.038 30A 8 43A Temperature Coefficient Voc -0 34%/°COpen CircuitVoltage(Voc) 369V 37 O372V 374V Isc 0.065%/°C_ Short Circuit Current(Isc) 8 46A 8 58 87A 9 OOA Normal Operating Cell Te4512°C° ° • s ' Module Efficiency 1461% 1491554% 15.85% } Operating Temperature -40°C-+85°C ' Performance at Low - ' - • . . t, ' Maximum System Voltage 1000V IEC /600V UL `Industry leading performance at low•arradtation Maximum Series Fuse Rating 15A environment;+95.5%module efficiency from an Application Classification ClassA ' Irradiance of 1000w/m'to 200w/mI' Power Tolerance 0-+5W (AM 1.5,25"°C) Next Generation Solar Module Under Standard Test Conditions(STC)of uradiance of 100oVJlm',spectrum AM l;5 and eels temperature of 25'C NewEdge,the next generation module designed for multiple ~'En6ineeringDrawings, ' _ ` CS0-235PX CS6P-240PX CS6P-240X C'_S6P-250PX CS60-255Px - - - types of mounting systems,offers customers the added Nominal MaximumPower(Pmax) 170W 174W 178W 181W 185Vy ".. ,. _ .,:_ value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27 2V 27 3V 27 4V 27 5V 27 aV appearance,auto groundingand theft resistance. • _ Optimum Operating Current(Imp) 6 27A 6.38A 6 49A 6 60A 6.71A I •` ' _� Open Circuit Voltage(Voc) 33 9V 34 OV 34.1V 34 2V 34 4V ` res, - . _ The black-framed CS6P-PX Is a robust 60 cell solar module " snort Circuit current(Ise) s asA s ssA 7 osA 7 19A 7 29A „ _ ,` 'ti:.p.,.,,.,•+ . Incorporating the groundbreaking Zep compatible frame. _Under Normal operating cell Temparature,lrradlance'ofaoo W/M%'Speetrum AM 1.5,ambient lemperature20*C," ' -wind speed 1 We The specially designed frame allows for rad-free fast Installation with the Industry's most reliable grounding McChar11C81 Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars Key Features,• silicon cells laminated with a white back sheet and framed ceuArrangement so(s x 10) with black anodized aluminum.The black-framed CS6P-PX ,oimenslons 1638 x 982 x40mm(64 5 x 38 7 x 1 571n) • -Quick and"easy,to instal[ .dramatically' Is the perfect choice for customers who are looking for a high Weight 20.5kg(45 2lbs) reduces installation time quality aesthetic module with lowest system cost. Front cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy • Lower system costs : can cut rooftop', ,1-Box IP65,3 diodes installation costs In half Best Quality912 . 235 quality control points in module production cable 4mm'(IEC)/12AWG(UL),1oo0mm Connectors MC4 or MC4 Comparable • Aesthetic seamless appearance -.low profile,,, ,' • EL screening to eliminate product defects Standard Packaging(Modules per Pallet) 24pcs with atito'levelmg and alignment.. _ • Current binning to improve system performance Module Pieces per contamer(40ft Container) 672pcs(ao'Ha) o • Accredited Salt mist resistant Built-in hyper-bonde'd,grounding`system if it's I,-V Curves(CS6P=255PX) mounted,it's grounded. Best Warranty Insurance Theft resistant hardware •'" 25 years worldwide coverage ' ` " " + `• - - • 100%warranty term coverage a{ r Section A-A i ----- -- Ultra-low parts count ";3 parts for the mounting Providing third party bankruptcy rights 350 I and`grounding`system ,. Non-cancellable j ie f • "°° • Immediate coverage _ 'Industry5rstco`mprehensivewarranty"msura"nce°bys� w,AM,Best rated leadin Insurance coin anies in the' Insured by 3 world top Insurance companies I i + [ g� P n-ov.7 � world Comprehensive Certificates 4 Indtist`ry`leading-plus only power'tolerance:0 -+5'11. ; 3 • IEC 61215,IEC 61730, IEC61701 ED2,UL1703, 1 710 •. Backward compatibility wlth.all standard rooftop and,. CEC Listed,CE and MCS ground,mountl,ng systems, .. IS09001 2008:Quality Management System _ ISO/TS16949.2009.The automotive quality spgFlf a, wnsinclud'edmthisdetasheetaresu6lecttochangew)thoutpriornotice. •'" Backed,By'Our"New 10/25 Linear Power Warranty management system Plus our.added'25Lyear_insurance coverage m IS014001.2004 Standards for Environmental About Canadian Solar management System Canadian Solar Inc. is one of the world's largest solar Canadian Solar was founded in Canada in 2001 and was lee% QC080000 HSPM The Certification for companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CS Q) irr 977. Added Value manufacturer of Ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing so%` s4^ FrOM warranty • Hazardous Substances Regulations solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. OHSAS 18001.2007 International standards for products of uncompromising quality to worldwide ee% h- _"` », ` occupational health and safety customers. Canadian Solar's world class team of °...5 REACH Compliance professionals works closely with our customers to „,s 10, 1s,' 20',' 25.2• P provide them with solutions for all their solar needs. e-, ,ee dvale Avenue West Guelph I Ontario N1K 1E6 I Canada ".10 year'product warranty on materials and workmanship O aE 4 SP f a uE(n',zE_ Tel:+1 519*837 1881 .125-year,in_ear power'°output warranty `J `` r www.canadiansolar.com www.canadlansolar.com o EN-11-1017Copynghl02012Canadlan Solarine solar=se Single Phase Inverters for North America soIar r SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE760OA-US/SE10000A-US/SE1140OA-US ° I SE3000A-US.1 SE380OA-US SES000A-US I SE6000A-US SE760OA-US 1 SE10000A-US 'SE31400A-US - .OUTPUT' V 80 @ 208 SolarEdge Single Phase Inverters • Nominal AC Power Output 3000 3800 5000 6000 7600 999900 208V•, 11400 VA u5400 @ 208V 10800 @ 208V 12000 VA Max AC Power Output 3300 4150 6000 8350 For North America , • 545D.a�124°� 1095°@Z4°� AC Output Voltage Mm-Nom-Max 1A _ � - - ✓ _ 183-2°8-229 Vac SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ AC Output Voltage Min.-Nom-Max UI v/ ✓ I � � ✓ ✓ � SE760OA-US/SE10000A-US/SE1140OA-US 211-240-264Vac - ACFre4uencyMm-Nam-Maxlti 593-60-605(wit hHl country setting57-60-605) Hz . .n--- '^a�---Prs-�' ^,;v' '?°,-w ,... 77 16 ,24 @ 208V 48 @ 208V ='l2,°' ;';`*•`` '.-�,�,` ..'�w Max Continuous Output Current 12 5 16 25 32 475 A <>.a. ' �a,� r'�' .y::, �.jrrc 21 Q 240V . . 42 Q.240V • • .. . w,r . �" .. ` '•� � ,> GFDI Threshold _ 1• _ _ - - - _ _ A �" :'` 3' , ` r,.�:r `�'^ 't e�" �"',.r'° �!�ms•'c Ublity Monitoring,Islanding Protection,Country Configurable Thresholds Yes Yes '^e.,. y - _ _ fir, �;'r•Q` ,�,''� ;:4:,',.ny , 'INPUT re,' j,�4'...�^� Maximum DC Power(STC) 4050 5100 6750 8100 1025013500 15350 W _Transformer-less,Ungrounded Yes Max Input Voltage 500 Vdc_ .. . .. .. .. `°,s?.'' ''„M"„a�,,, ;:( i • `�G artanlY'� +%`fir'�'-.a,^";, ,&Vi"µ Nom DC Input Voltage 325 @ 208V/350 @ 240V Vdc 16 5 @ 208V 33 @ 208V ` _ •i; -"' �'s)-en�;F- , '_„ 'r, Max InputCurrenti'I 95 13 18 23 345 Adc r a s.'ai r :k' _ 15 5�a 240V ( 30.5 ae 240V 4tW' '11.i,_ Max Input Short Circuit Current 45 Adc �°i?;;�'�'i;n _,f,"" Reverse-Polanty Protection _ - - _ Yes - . ,• _ _ Ground-Fault Isolation Detection _ _ _ 6001oSensitivity _ `i'$ " •" y, Maximum Inverter Efficiency. 97.7 98 2 983 983 98 98 1 98 98 975 975 975 97.5 @ 208V 97 @ 208V - -�fi ,-4••- -- _ ""' °gym ' 4;'p :,ti. Gr CECWeighted Efficiency 975 'say'+ -``$', 98(P 240V I. ( 97 5 @ 240V (. ?a, ; .4 �. . Nighttime Power Consumption <2 5 <4 W L4 y' ADDITIOINALFEATURES',, Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional) E, <z `` j,`',7, t ,_ ,...,__ _:(t,;si•, ¢ s.`r 'q Revenue Grade Data,ANSI C32.1 _ Optional") a ",,,, •' + _ ., • !.` £,, --.�.. Rapid Shutdown—NEC 2014 690 12 Functionality enabled when SolarEdge rapid shutdown kit is installed(4) _ STANDARD'CONIPLIANCE ' Safety UL1741,UL1699B,UL1998,CSA 22 2 Grid Connection Standards IEEE1547 • Y! Emissions ,• FCC partl5class B i , i, 1 • 1, R3 INSTALLATION SPECIFICATIONS' i o it, , a>r ^ r we; ;'-»-" "A'''' • -..)t",� AC output conduit size/AWG range _ 3/4"minimum/16-6 AWG _ _ 3/4"minimum/8-3 AWG DC input conduit sae/#of strings/ 3/4"minimum/1-2 strings/ AWG range 3/4"minimum/1-2 strings/16-6 AWG 14-6 AWG _ k, • -r - '` Dimensions with Safety Switch 30 5 x 12'S x'10 5/ in/ erjF';,_ 30Sxl25x7.2/775x3l5xl84 a,-z ,(HxWxD) - _ - _775 to 315 x 260 mm• Wetphtwith Safety Switch 512/232 I 547/247 884/401 lb kg Natuial - .. convection Cooling Natural Convection and internal Fans(user replaceable) fan(user e aceable r I The` est choice dor° ®laEd e`,enabid:s"steric,° - ..g- -�- y - •z `.b Noise <25 <50 dBA .,® 11's Min-Max.O Operating Temperature I r t ction•T` e 1 for'NEC 2011690 coin`liance tante A'rated arrfau t o e ), p ,' -`YP g - - g p �rYp, P' -13 to+140 -25 to+60-40 to+60 versio s;.•�;,>'� ,..'., '.�._ Ran e / ( n avadableisi) •F/•C Superi il� iiidieric` 98/0) ; .,. Y Ymi`" :I '';x .,j Protection Rating NEMA311 Small'li htwei ht antl eas to Installro d A h. 'royided'bracket' „ n - g, g y p, a- _ _ For other regional settings please contact SolarEdge support _ - (4 A higher current source maybe used,the inverter will limit its input current to the values stated 4r �i BDllt'In modDle'level monitorin .. °�'` - 'i, pi Revenue grade Inverter P/N SE—A-US000NNR2(for 760OW inverter SE7600A-US002NNR2) S $,;• 't g �`,tt -' Rapid shutdown kit PIN SE10MRSD-Sl Internet�connection.throughrEthernetor7wlreless. M-40-rd—P/N SEmaA-USWONNU4(for 7600Winverter SE7600A-U5002NNU4) rr yr indoor and indoor installation 'O t -x k F,ixed voltage inverter;'DC/AC conversion°only' „ , „ ,. v ,Pre=assembled'SafetySwitch,focfa"ster,mstallation, s' 1. Optional revenue gradedata,ANSI C12.1rt, sunswsc ;°s USA GERMANY ITALY FRANCE JAPAN CHINA AUSTRALIA THE NETHERLANDS ISRAEL www.solaredge.us s< OPTIMIZE)13Y • so I a r - . • so I a r ' • • SolarEdge Power Optimizer- Zep Compatible'" Module Add-On For North America P300-ZEP SolarEdge Power Optimizer - f P300-ZEP(for 60-cell PV modules) - INPUT Zep Compatible''" Module Add-On Rated Input DCpoweri'i 300 W Absolute Maximum Input Voltage(Voc at lowest temperature) 48 Vdc For North America P300-ZEP MPPT Operating Range 8-48 Vdc Maximum Short Circuit Current(Isc) 10 Adc - ",Vr,- ,- Maximum DC Input Current 12.5_ Adc Maximum Efficiency 99.5 % - • Weighted Efficiency 988 % Overvoltage Category 11 r; OUTPUT DURING„OPERATION(POWER-OPTIMIZER CONNECTED TO OPERATING INVERTER) ,4- r ;` TM'sr"'"v, x: ;;u +, F' * Maximum Output Current 15 Adc =x Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) _ c Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE Y • EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 SafetyIEC62109-1(class II safety),UL3741 RoHS Yes INSTALLATION SPECIFICATIONS f''owao� Maximum Allowed System Voltage 1000 Vdc Dimensions including mounting bracket (W x L x H) 141 x 256 x 40.5/S.55 x 10 08 x_1.59 mm/in i Dimensions excluding mounting bracket (W x L x H) 141 x 212 x 40.5/5.55 x 8 34 x 159 mm/m 1170/2.54Wkg/lb elght(Indudmg cables and mounting bracket) �$! Input Connector MC4/Amphenol/Tyco Out ut Connector P _ - Double Insulated;Am phenol Output Wire Length .0.9S/3.0 m/ft Operating Temperatu re Range -40-+85/-40-+185 'C/'F Protection Rating IP65/NEMA4 r Relative Humidity0-100 (')Rated STC power of the module Module of up to r5%power tolerance allowed PV SYSTEM DESIGN USING A SOLAREDGE INVERTER SINGLE PHASE: THREE PHASE THREE PHASE ` 208V, 480V a Minimum String Length(Power Optimizers) 8 10 18 7 I p I' • '. "' „ Maximum String Length(Power Optimizers) 25 25 50 les" Certified.Ze Com alible bracket ' COtYI atlb(e with Ze Groove fPalTled modu Maximum Power per String 52.50 6000 12750 W — p p TMt .— Mitigates all types of module mismatch losses,from,”. - Parallel Strings of Different Lengths or Orientations Yes = Attaches to module frame without screws-reduces on-roof manufacturing tolerance to partial shading' labor and mounting costs,, - Flexible'system design for'maximum space utilization` t Power optimizer.equipment grounded tHrough the bracket Next generation maintenance`witWmodule-level monitoring : '" ,.;j rv-,x.,..._..,.m«..,..-n.n...,...-.rv. — Up to 25%more energy" — Module-level voltage shutdown for installer and firefighter #� " Y ' y - —,Superior ef_hciency(99.5%) safety CE ON t��..�..w_.r. .-__......�_�._....�-- -. ....v_..-...... -.... -,....._-.._..-w....i.--.--.... sem_-.�._ �.e. ..�..---...��.._._.�.-_.. " USA GERMANY ITALY FRANCE JAPAN CHINA ISRAEL AUSTRALIA www.solaredge.us ;. , 'are tmatern"'k.of th-l".spamm...h.-Date;12,2013.V.0t.Sutject to change Without notice, I 6�-tee_W_r