Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
40571-Z
FFatCaG Town of Southold 1/25/2017 o - P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38794 Date: 1/25/2017 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 14216 Oregon Rd, Cutchogue SCTM#: 473889 Sec/Block/Lot: 72.-2-5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/23/2016 pursuant to which Building Permit No. 40571 dated 3/29/2016 v was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Hume,Daniel of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40571 08-02-2016 PLUMBERS CERTIFICATION DATED Authorized Signature I TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy • o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40571 Date: 3/29/2016 Permission is hereby granted to: Hume, Daniel 300 E 54th St Apt 8L New York, NY 10022 To: install roof-mounted solar panels on existing single-family dwelling'as applied for. At premises located at: 14216 Oregon Rd, Cutchogue SCTM #473889 Sec/Block/Lot# 72.-2-5 Pursuant to application dated 3/23/2016 and approved by the Building Inspector. To expire on 9/28/2017. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 B i ing Ins or Form No.6 0 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. 5 L2_z_ EN New Construction: V (sn cML� Old or Pre-existing Building: (check one) ow al,o B bt'N h Location of Property: l q2 l(o Ogeo w PO4-P CV rC*40!;a,i5- House No. Street Hamlet Owner or Owners of Property:—1 AA) M 6 Suffolk County Tax Map No 1000, Section 77— Block 2 Lot Subdivision (� n Filed Map. Lot: Permit No. [ l Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ V ApptpantlSignature pF SO!/Th®l 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 • �Q roger.riche rt(aD-town.southoId.ny.us Southold,NY 11971-0959 BUELDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Daniel Hume Address: 14216 Oregon Road City: Cutchogue St: New York Zip: 11935 Building Permit#: 40571 Section. 72 Block: 2 Lot: 5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: NRG Home Solar License No: 55690-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect F1 Switches Twist Lock Exit Fixtures TVSS Other Equipment: 9.880 KW Roof Mounted Photovoltaic System to Include, 38- JKM 260 Panels, 1-SE 10000 Inverter, 1-60A A/C Disconnect Notes: Inspector Signature: Date: August 2, 2016 OOElectrical 81 Compliance Form.xis rjF SOUlyolo slk nuMv, TOWN OF SOUTHOLD BUILDING DEPT. 765-1602 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) `f] ELECTRICAL (FINAL) REMARKS: DATE �� INSPECTOR , ' �H� nrge bringing homes into the future. 0 lam Hometo W ° '� 69 Terminal Street,Albany,NY 12206 1-800-75-SOLAR ® � SOLAR January 16, 2017 Attn: Building Inspector Town of Southold U EQMV14 � Re: Customer: Daniel Hume G ' 14216 Oregon Road JAN 2 4 2017 Cutchogue, NY 11935 Building Permit#40571 BUILDING DEPT. TOWN OF SOUTHOLD Dear Inspector, On behalf of NRG Home Solar, I have reviewed the documentation on the installation of the photovoltaic(PV)system at the above referenced location. This documentation was submitted to me per my request and under my direction. The documentation includes photographs of the installation as well as a quality control checklist filled out by quality control team on January 16, 2017. 1 have verified that the documentation is complete as requested and that conformance with the quality control plan has been completed to my satisfaction. I certify that the solar system including the panels and system has been installed in accordance with the approved construction documents, manufacturer's requirements, and the 2015 International Residential Code and 2016 New York State Supplement. �OF NEIN Y O If you have any questions, please contact me. c Kq�,F2, Sincerely, >�•� it �. -U - r C9 �� .. 086813 PESSIONP�. Daniel C. Kaufman, PE Structural/Civil Engineer Phone#: (845)558-6907 CC: NY LI Office NRGHomeSolar.com :..... 0-a.. FIELD II�Sg� QN0�'s AAS CO S FdmA.tolq(1ST) ROUGH FRANVQ& (� PLUMBING ' H INSULATION.?FA N,Y. , STATE ENE-PlOY COM FINAL . 1 TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUII,,DING,.PEPARTMENT Do you have or need the following,before applying? VOWN'HA'L Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. � � Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined 3 ,20—L(� Storm-Water Assessment Form Contact: Approved 13 ,20� Mail to: Disapproved a/c Phone: Expiration ,204� M Buil ing Inspe D �(ZIEG `� ATION FOR BUILDING PERMIT MAR 23s, 2016 Date mac Z7 ,20 iP INSTRUCTIONS a.This appligbI &NUMIDEMpletely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,acctT4PMtQMGU3ffQWaccording to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance-or has not been-completed-wiihin-18 months'froi'n such date.If'no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing code, and re ons,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) 1-10 W3--t.gl1la� Ptoot cc; STt leo (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Name of owner of premises N-k (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. 934S3 —1-� Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 1421(o QREf,O. M _(20AD CMR 06 U C-- House Number Street Hamlet County Tax Map No. 1000 Section -72— Block . Lot Subdivision Filed Map No. Lot 2: State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancyt+�C• 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work 4. Estimated Co Fee (Description) (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises?YES NO 14.Names of Owner of premises twcr t, u Address C ff s; �-µms{ 11410-5 one No.at'1°?.S3-gS 8 Name of Architect pAgs� dElPAl.A(6 Address Xa wt iio E �p �� I'�hone No $46,65 jr• kA0-7 Name of Contractor N9,,Q d ouljrwa Ss LAR- Address Td-Phone No.OB i•441q•$52.3 IWW thk t%I t b 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO L—` * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on/survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO t/ * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF An being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the-S® 49 rbla ;e t S — (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. S orn to before me thi an day of emLrc� 201�0 MELISSA MAHONEY No VcPUBLIC-STATE OF NEW YORK ignatu of Applicant No. O1 MA6325511 Qualified in Suffolk County My Commission Expires May 26, 2019 Scott A. Russell ,��°su �� �T�O�][�l��l[\�vA\'7C']E][� SUPERVISOR1\�][A NN A\tG IEMIENT SOUTHOLD TOWN HALL-P.O.Box 1179 0 53095 Main Road-SOUTHOLD,NEW YORK 11971 Town Of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT T INVOLVE ANY OF THE FOLLOWING: Yes No (CHECK ALL THAT APPLY) ❑&A'. Clearing, grubbing, grading or stripping, of land which affects more / than 5,000 square feet of ground surface. ❑ B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑ C. Site preparation on-slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑OD. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. E]Fj E. Site preparation within the one-hundred-year f loodplain as depicted on FIRM Map of any watercourse. ❑ F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information,Tate & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control-Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT (Property Owner.Design Professional,Agent.Contractor,Other) S.C.T.M. #: 1000 Date MsImt NAME IYYIQ,( a lrl 72 2 —5 T Section Block Lot FOR BUILDING DEPARTMENT USE ONLY**** Contact Information (Td,ph-,NlumbM Reviewed By: — — — — — — — — — — — — — — — — - - - - - - - -Date Property Address/ Location of Construction Work: — — — — — — — — ��� E] Stormwater for processing Building Permit. Stormwater Management Control Plan Not Required. (gs Stormwater Management Control Plan is Required. El (Forward to Engineering Department for Review.) FORM # SMCP-TOS MAY 2014 - OF S©Uryo Town Hall Annex Telephone(631)765-1802 54375 Main RoadQ2 765- P.O.Box 1179 r0 er.d ert oWri sO Otd.n .us Southold,NSC 11971-0959 BUILDING DEPARTMENT TOWN OF SOVTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: � fn yeare K � �.. Date: Company Name: Name: License No.: Address: 1170 By Gp-C 9TH app � q �,�� Phone No.: �l ions JOBSITE INFORMATION: (*Indicates required information) *Name: lV r L vA4E *Address: N a tJ * YYM U *Cross Street: *Phone No.: q, 7 Permit No.: p Tax-Map District: 1000 ection: 72-- Block: Z Lot: S6 *BRIEF DESCRIPTION OF WORK(Please Print Clearly) Z'PV c t= v _ (Please Circle All That Apply) Is job ready for inspection: YES/ NO Rough in Final *Do.you need a Tern Certificate: YES/ O Temp Information(if-needed) *Service Size: 1 Phase 313hase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION ki 82=Request far Inspection Form 'J� 72-- - 2 _ vim_ TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET I ✓ VILLAGE DIST SUB LOT Z 1)yl I ACR. REMARKS`" f Ud5----S dtf Iy4S1 0/1 E ck-c?il v TYPE OF BLD. a . (f s ' Manz, `rrw, jw , S-LI)S-4�jOi1 1/0 n?,I :Ty (re g/-r"f. PROP. CLASS LAND IMP TOTAL DATE 6 16-7 6 '33,A S npew d wel(i r, 5 5 U OLI/2- 0 -, 66 ql 5 l2. 0- 8P 0- '-6w Poo 6000 172-0 3 00 FRONTAGE ON WATER 3� 5gS2 '� �211�aILLA BLE FRONTAGE ON ROAD yol� ) WOODLAND DEPTH MEADOWLAND BULKHEAD HOUSE/LOT TOTAL 4. -tet tr �k , ....��r17■■■■V■�■■■■■■■■■■ItJ■'■■■■■■ , at wH : — �.,� t ;:' z -. . :' ■■''■■■■i�■■` ■■i■►`!YI■■■■■■■II�JIF■■I■■■ 3:, - :�uIL(LII �I II ITIII � � i IIIII�lillltl�l �n • ' '-�``� �' tu�t ` �■■■■■■■■■■■■■�1�11�■■■■■■■S'(if�ii�ll�■■ �lilli�lt �- OM111111111- tr SO!/r�®� Town Hall Annex Telephone(631)765-1802 54375 Main Road y Fax(631)765-9502 P.O.Box 1179 G Southold,NY 11971-0959 ®lac®UNT` i August 24, 2016 BUILDING DEPARTMENT TOWN OF SOUTHOLD NRG Home Solar 170 Wilbur Place, Suite 100 Bohemia, NY 11716 Re: Hume, 14216 Oregon Rd, Cutchogue TO WHOM IT MAY CONCERN: The Foilowin Items(if Checked)Are Needed To Complete Your Certificate of Occupancy. NOTE: a tion letter required stating the panels were installed to the roof per NYS Building Code " Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 40571 —Solar Panels -777 - - _ ' _ - � . � , - +- - - ' ,- ,_ -, .f ttif lfleriwbn,e VaPenYoiiM9orto0i Coway Caaenmfro of LeDPr,LIcenUrg� -{ . -F, ,.,.:y _ � �,.�� _ - - - _ _ - - - dCenmeier�lferta PceiMabn a11M 4cemeAoaa nol'puaraNaeif vdMnX t _ ' .. - •SUFFOLK COUNTY DEPT OF LABOR, Add.Oonal Business Names LICE CONSUMER AFFAIRS , N NSI O 8CM _ = MASTER - r RICIAN ELECT 'JOS EPH.P STRIANO i. — - - ;L¢ense Category This cedifies that the waeees uuc = ,,,<•., £. bwrensdu R�FDIADNDSTICSSOLARAND 3„ t duty ELECTRIC OF NY LLC 013A w licensed by the y County o1 Su folk �'• '' 08!17!2015 a 55690-ME - ; �r F f 0B101i2017 ..�.; .•,, .,, -� •,. - = , ri Y - �.. Zi. 'ov -'-e- i6l� 10 EY: Alp li RPM 1 99 1 1 t. -lw -W Of 0.1�1 I t g nr Home 170 Wilbur Place,Suite 100,Bohemia,NY 11716 1-800-75-SOLAR ®® SOLAR March 22, 2016 D Solar Panel Installation VAR 2 2 2016 Hume Residence 14216 Oregon Road BUILDING DEPZ Cutchogue, NY 11935 TOWN U oumffULD Dear Sir/Madam: Please find the following attached documents for the Hume Solar Photovoltaic Installation at 14216 Oregon Road Cutchogue,NY: • Check made payable to the Town of Southold for the fee of$200 • Two (2) original Southold Building Permit Applications • Application for Certificate of Occupancy • Application for Electrical Inspection • Stormwater Management Worksheet • Four (4) Sets of stamped and sealed architectural plans with spec sheets • Roof Diagnostics Solar's Insurance Information,including Workers Comp, Disability, &Liability documents. • Copy of ME License Please do not hesitate to contact me with any questions or concerns. I can be reached at 631-416-5525. Sincerel Jaim o an Permitting Specialist NRGHomeSolar.com APPRO U ED AS NOTED DATE:3 &P.# S -71 ELECTRICAL FEE: � � BY: INSPECTION REQUIRED NOTIFY BUILDING DEPAR AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONT RUCTION MUST BE COMPLETE `OR C.O. ALL CONS;R��CTION SHALL MEET THE RETAIN STORM WATER RUNOFF REQUIREMENTS OF TI-?E CODES OF NEW YORK STATE. N(,)T kiuSPONSiaLE FOR PURSUANT TO CHAPTER 236 DESIGN OR CONSTRUCTION ERRORS. OF THE TOWN CODE,_ COMPLY WITH ALL CODES--OF NEW YORK STATE &TOWN CODES AS REQUIRED AND CONDITIONS OF 48ROWT04 — OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY r ' nrgm bringing homes into the future. M®® Home0 69 Terminal Street,Albany,NY 12206 � � SOLAR 1-800-75-SOLAR March 18,2016 Re: Hume, Daniel&Lori Residence 14216 Oregon Road Cutchogue, NY 11935 Jurisdiction:Town of Southold Attn: Building Official This letter is to inform you that Daniel Kaufman, PE has performed a structural analysis of the roof for the house referenced above. The analysis was performed to determine if the existing roof system is structurally adequate to support the new photovoltaic modules in addition to the code required design load values applicable in the 2010 New York State Building Code.Our analysis is isolated only to the areas where the modules are intended to be placed. The modules are to be located on the following roof planes: SP# Rafter Size Rafter Spacing Rafter Max Span Total Width of Roof 1 2 X 12 16 inches 20'-8" 23'-1" 3 2 X 12 16 inches 12'-0" 12'-6" 4 2 X 8 16 inches 11'-1" 14'-10" Each roof has been analyzed with design loads as follows: Ground Snow(Pg)=20 psf Wind Speed (V)=120 mph SP#1,#3,  It has been determined that the roof structure is adequate to support the new PV modules in addition to the code required design loading. Attach the module rail brackets to the roof with 5/16" lag bolts at 48"OC max.with a minimum penetration of 2.5" into the wood members. It is a violation of NYSED 7209 for any person, unless acting under the direction of a licensed professional, to alter an item In any way. If an item bearing the seal of a licensed professional is altered, the altering licensed professional must attach the notation 'altered by'with his seal,signature, date of alteration, and description of the alteration. If you have any questions regarding this analysis or the construction documents for the Hume residence, please feel free to contact me. Sincerely, \�0F NEW yob /T- \ �N Daniel C. Kaufman, PE Structural/Civil Engineer E Phone#: (845)558-6907 — (' V .' i w CC: LI Office X86813 ��O A) OFESS\O�P NRGHomeSolar.com HUME RESIDENCE _._,. - 9.880 kW (DC) PHOTOVOLTAIC SYSTEM =}' µ ' _ ` �w` -`fv 14216 Oregon Road Cutchogue, NY 11935 - P �vi rA`• �. . ,•a�'A �*„�'j,�tAZ' ���1jr`y� '� '�e\ �y � Baa;• �.�r�-`�F;�?r�3^�". s.+.� •�.r�6a�'3'.� .�` S 6-JKM260P-606 - ., .s-" ri; % •'Y;µ., SOLAR PANELS fir EXISTING SCOPE OF WORK: POOL&SPA EXISTING HOUSE 38]KM260P-2606 SOLAR PANELS SOLAR PANELS LL U o SE10000A-US-000NNR2 INVERTER °w Z o INVERTER -� w ROOF TOP AND WALL MOUNTED ELECTRICAL EQUIPMENTo 5D REQUIRED PER CODE,AH]&FIRE DEPARTMENT „> w o i o= °o Nn CONNECT TO 200A/ 200A MAIN SERVICE PANEL "° w o N o 14-JKM26OP-60B TOTAL SYSTEM SIZE 9.880 kW(DC) SOLAR PANELS SHEET INDEX: _ ow4�S E1 - SITE PLAN E7 - SINGLE LINES E2 - NOTES E8 - ELECT. NOTES E3 - PROPERTY PLAN E9 - SIGNAGE EXISTING 200A BUS E4 - ELEVATIONS E10+ - CUT SHEETS EXISTING 200A TOP FED E5 - ROOF PLAN MAIN BREAKER SERVICE _ DETAILS SOLA PANELS (N)SE10000A-US-OOONNR2(24OV) p SOLAR PANELS VICINITY MAP INVERTER INTEGRATED DC DISCONNECT ARC FAULT N Jest iitii►', tlnry,;x,; �y4 PROTECTED (N)60A AC DISCONNECT N ' 240V NEMA-3R(INSIDE) EXISTING SERVICE POINT~ r• - ;t -=_, • _ m N &UTILITY METERING <. `* r;1d216,t�ra�cari.Rd,"Y;t (N)60A AC DISCONNECT 240V NEMA-3R(OUTSIDE) SITE PLAN SCALE:1/16"=1'-0" -A ^!q Jtttt F-` NOTE: ALL SCALES SET TO 11X17 SHEET SIZE SOLAR PHOTOVOLTAIC SYSTEM NOTES: ABBREVIATIONS All materials,equipment,installation and work 9.All conductor exposed to weather shall be 22.Flexible,fine-stranded cables shall be A AMPERE shall comply with the following applicable codes: listed and Identified for use in direct sunlight. terminated only with terminals,lugs,devices or AG ALTERNATING CURRENT P Y AHJ AUTHORITY HAVING JURISDICTION 2012 IBC [NEC 690.31(B),310.8(D)] connector that are Identified and listed for such use. BLDG BUILDING • 2012 IRC 10.The module conductors must be type USE-2 [NEC 690.31(F)] CONC CONCRETE 2011 NEC or listed for photovoltaic(PV)wire. (NEC 23.Connectors shall be of latching or locking type. CB COMBINER BOX CEC CALIFORNIA ELECTRICAL CODE 2012 UMC 690.31(8)) Connectors that are readily accessible and operating CU COPPER 02012 UPC 11.All conductors shall be marked on each end at over 30 volts shall DP DISTRIBUTION PANEL • 2012 IFC for unique identification. Require tool to and marked Not 24.Re " DC DIRECT CURRENT t� q q P EGC EQUIPMENT GROUNDING CONDUCTOR • 2013 Building Energy Efficiency Standards 12.PV module negative shall be un-grounded.All Disconnect Under Load"or"Not For Current (E) (EXISTING) i • Authority Having Jurisdiction grounded conductor shall be properly color Interrupting".[NEC 690.33(C)&(E)(2)] FV FIELD VERIFIED L,l� • Fire Author) Having Jurisdiction identified as white.[NEC 200.6] 25.Equipment rounding conductor for PV modules GALV GALVANIZED Authority 9g GEC GROUNDING ELECTRODE CONDUCTOR 0,, n 13.PV system connected on the load side of the smaller than 6AWG shall be protected from physical GND GROUND 1. Existing plumbing vents,skylights,exhaust service disconnecting means of the other damage by a raceway or cable armor.[NEC 690.46 Hoc HOT DIPPED GALVANIZED IL T CURRENT outlets,ventilations intake air openings shall not source(s)at any distribution equipment on the &250.120(C)] imp CURRENT AT MAX POWER be covered by the solar photovoltaic system. premises shall meet the following[NEC 26.Equipment grounding conductor for PV systems INVL INVERTER 2.Equipment.Inverters,motor generators, 705.12(D)]: without Ground Fault Protection(GFP)and installed kVA SHORT CIRACMUIIT PERE CURRENT KILOVOphotovoltaic modules,photovoltaic panels,ac 14.Each source connection shall be made at a on non-dwelling unit must have ampacity of at least kW KILOWATT photovoltaic modules,source-circuit combiners, dedicated circuit breaker or fusible disconnecting 2 times the temperature and conduit fill corrected LBW LOAD BEARING WALL 9705.12(D)(1)] P ty[ ( )] MCB MAIN CIRCUIT BREAKER �MINIMUM o W o 802 and charge controllers intended for use In means.[NEC circuit conductor am aci NEC 690.45 BMINw v � �M photovoltaic power systems shall be Identified 15.The sum of the ampere rating of the 27.Fine stranded cables used for battery terminals, MSP MAIN SERVICE PANEL ,w o N and listed for thea application. 690.4 D)) overcurrent devices in circuits supplyingower to devices and connections require lugs and terminals (N) (NEW) 0} PP (NEC( ( p q g N3R NEMA 3R,RAINTIGHT OUTSIDE RATED �a o ro$? 3.All outdoor equipment shall be NEMA 3R rated, the busbar or conductor shall not exceed 120% listed and marked for the use.[NEC 690.74] NEC NATIONAL ELECTRICAL CODE �>W ^` NO� N^O including all roof mounted transition boxes and of the rating of busbar or conductor.[NEC 28.Grounding bushings are required around NTS NOT TO SCALE 6s Lu o t switches. 705.12(D)(2)] pre-punched concentric knockouts on the DC side of OC ON CENTER 4.All equipment shall be ro erl rounded and 16.The interconnection point shall be on the line the stem250.64 C OCPD OVERCURRENT PROTECTION DEVICE o �U P P Y 9 P system(NEC( ) P POLES-BREAKER POLES- y= bonded in accordance with NEC article 250. side of all ground-fault protection equipment. 29.Grounding electrode conductor will be PL PROPERTY LINES 5.All circuits connected to more than one source [NEC 705.12(D)(3)] continuous,expect for splices or joints at busbars Pv PHOTOVOLTAIC v PVC POLYVINYL CHLORIDE w shall have overcurrent devices located so as to 17.Equipment containing overcurrent devices in within listed equipment. RR ROOF RAFTER o provide overcurrent protection from all sources. circuits supplying power to a bus bar or (NEC 250.64 C) SBC SOLID BARE COPPERLANE a [NEC 690.9(A)] conductor shall be marked to indicate the 30.All smoke alarms,Carbon monoxide alarms and SPL Su PBPLPANELL 6.All photovoltaic(PV)modules shall be mounted presence of all sources.[NEC 705.12(D)(4)] audible notification devices shall be listed and SCH SCHEDULE on the roof.Additional equipment of the PV 18.Circuit breaker,if backfed,shall be suitable labeled in accordance with UL 217 and UL 2034. SS STAINLESS STEEL stem shall be located outside the building near PTH PRACTICAL TESTING CONDn10NS Sy 9 for such operation.[NEC 705.12(D)(5)] They will be installed in accordance with NFPA 72 swH SOLAR WATER HEATER the main electrical services.[NEC 690.14(C)] 19.To minimize overheating of the busbar in and NFPA 720. (IRC 2013 R314&R315). TYPTYPICAL 7.The utility interactive inverters shall panelboard,the panelboard main circuit breaker VNo VOOLLESS NOTED OTHERWISE `=w automatically de-energize its output to the and the PV power source circuit breaker shall be Vmp VOLTAGE AT MAX POWER connected electrical production and distribution physically located at the opposite end of the Voo VOLTAGE AT OPEN CIRCUIT network upon loss of voltage in the system and busbar. W WATT g shall remain in that state until the electrical 20.All the NEC required warning signs,markings, production and distribution network voltage has and labels shall be posted on equipment and h been restored.[NEC 690.611 disconnects prior to any inspections to be h 8.Due to the fact that PV modules are energized performed by the Building Department inspector. whenever exposed to light,PV contractor shall 21.Metallic raceways or metallic enclosures are o disable the array during installation and service required wiring method for inside a building for by short circuiting,open circuiting,or covering PV system.[NEC 690.31(E)] •OCCUPANCY TYPE: R-3 "_`" the array with opaque covering.[NEC 690.18] •CONSTRUCTION TYPE TYPE V-B �� *UNSPRINKLERED 1E 'i u t S r�93. o LL LLJ c IL C e �s NSWU Ni CM�� SObi CO} \ w om mz H F wow on�O \ Nr D�W O�N R.V_. �N= U o w 510, 92 j r�85 y3 3 \ F3 NN N S N PROPERTY PLANSNEE NUMBM SCALE:1/32"=1'-0" E3 . � � � � - \� . � F11 \ok \ �m a\§ ]§\{ H§k7 / / 00 C114ms §\3® ®§w » ! 9 o§0 §��3 ) 2 � § § (§) § § ! § & � � \ § \ F�l § | § | § ELEVATIONS \ SCALE:m E4 SP#1 PITCH AZIMUTH MATERIAL SP SQ FT ARRAY SQ.FT RAFTER SPECS RAFTER MAX SPAN MAX ATTACHMENT SPAN LAG SIZE SHADE 31 134 Comp.Shingle 526.51 24734 2x12 @ 16"0 C. 20'-8" 48"O C 5/16"x4"S.S. 91% SP#3 PITCH AZIMUTH MATERIAL SP SQ.FT ARRAY SQ FT RAFTER SPECS RAFTER MAX SPAN MAX ATTACHMENT SPAN LAG SIZE SHADE 28 224 Comp.Shingle 193.22 105.99 2x12 @ 16"0 C 12'-0" 48"O C 5/16"x4"S.S. 100% \ PITCH AZIMUTH MATERIAL SP SQ.FT ARRAY SQ.FT RAFTER SPECS RAFTERMAXSPAN MAX ATTACHMENT SPAN LAGSIZE SHADE SP#4 �v\ 41 224 Comp Shingle 55625 31800 2x8 @ 16"O.C. 11'-1" 48"O.0 5/16'x4"S S. 91% Lm Q: 93 ATTACHMENTS NJf @ 48"O C.MAX (TYP.) ALL ARRAYS EXISTING EXISTING POOL&SPA HOUSE LLW o Z nm wiW c- ocnK— JaFn Nc;0Z om aW on a o o.-.O mak. WOW f-�,L at,46 1 aH2 Seo 4ty1 w a VENT TO BE RELOCATED WITH LOW PROFILE VENT NEW PV CONDUIT TO BE RUN WITHIN "v Y ATTIC AND HIDDEN FROM VIEW. ` CONDUIT TO BE PAINTED TO MATCH 93 THE EXISTING SURFACE. v Z Nm (E)TRENCHING CONDUIT ROOF PLAN y SCALE*1/16"=1'-0" W EQUIPMENT LEGEND SHEE NUMfiER AL ACCESS COMBINER JUNCTION NEG C DISCONNECT w/ orn DC DISCONNECT w/ LOAD CENTER w/ DISTRIBUTION PANEL WALL INVERTER w/ DEDICATED PV SERVICE POINT& E5 LADDER `a BOX BOX © ARNING LABEL WARNING LABEL WARNING LABEL ov w/WARNING LABEL WARNING LABELO SYSTEM METER °P UTILITY METERING STRING LEGEND S1 - STRING 1 S2- STRING 2 STING EXISTING OL&SPA HOUSE s` 6` LL W o 5` �yw oNR� 5` S` 00 coo> S` a� NAmZ r o n��oo �N= s� s2 GQj 0 tis v5 s2 s OO '� � a z p s2 v5 c4-- vy sz vs sa � S m a d N N STRING PLAN SCALE.3/32'=V-0" E5.1 C■1 PV MODULE - UNIRAC SOLARMOUNT RAIL WITH ECO FASTEN GROUND WEEB & L-FOOT MODULE CLAMP � 5/16" EPDM BONDED PV MODULE V 304-18.8 SS WASHER COMP SHINGLES L-102-3" BRACKET* (OTHER- GREEN FASTEN FLASHING: OPTIONS AVAILABLE) ECO-GFI-BLK-812 WITH GF-1 FLASHING ECO-CP-SQ COMPRESSION BRACKET I O E---- --- '--- ` 5/16"x4" SS LAG BOLT WITH 2.5" 1 -----� J MINIMUM PENETRATION SEALED WITH ,. ` --- APPROVED SEALANT LAG BOLT 5/16' �} (TO BE VERIFIED) ij (TO BE VERIFIED) STANDOFF DETAIL Aw 22'0 o SCALE:NTS "w Z o°° W n oC1 0�c} oW om2d EXISTING 200A BUS EXISTING y o�' o PO`17, � 200A MAIN BREAKER 120/240V 1� 04 W o rn r r oaf o....� 3W MAIN PANEL(INSIDE) 0 o �v EXISTING 200A UTILITY METER 240V NEMA-31R.(OUTSIDE POLE) W I /-NEW 60A AC DISCONNECT a SE10000A-US-OOONNR I —1 I 240V NEMA-3R(OUTSIDE) (240V)INVERTERS INTEGRATED DC DISCONNECT ARC FAULT PROTECTED NEW 60A AC DISCONNECT $ m 240V NEMA-311(INSIDE) y $ o GROUND LEVEL(t0'-0") � m OUTSIDE ELECTRICAL ELEVATION DETAIL �"aaER SCALE:WS E6 SERVICE INFO INVERTER SPECS MODULE SPECS OPTIMIZER SPECS ASHRAE AMBIENT TEMPERATURE SPECS MAX VOLTAGE UTILITY COMPANY: MSP VOLTAGE: INVERTER:SE10000A-US-000NNR2 MODULE TYPE: QTY: WATTAGE: FRAME COLOR: OPTIMIZER:P300 High Temp ABOEAR E EXTREME (VOLTAGE x NEC=MAX VOLTAGE) PSEGLI 240V QTY:I JKM260P-60B 38 260 BLACK QTY:38 MAX STRING 2%Avg. 0.5" MIN r VOLTS 6907 VOOLTLT S MSP LOC: SERV,TYPE: MSP GROUND: VOLTAGE: WATTAGE- CEC EFF: Voc:38.1 Isc:8.98 Imp•8.37 Vpmax:31.1 CELL:60 WATTAGE: 330 C 550 C -140 C 500 x 12= 600 SOUTH UNDERGROUND (E)ROD 240 10000 97.5% ISC:15 5250 DOES NOT PERTAIN TO SOLAREDGE V� WIRE OCP FOR WIRES CONNECTED TO BREAKERS TO EQUIPMENT TERMINALS ARE RATED AT 75'C. STRING AMPERAGE NOT TO BE GREATER THAN THE SIZE OF THE BREAKER. EXCEED THE 75'C RATING OF THE WIRE THAT IS ATTACHED TO THE TERMINALS. p E.��) SE1I0000A-U5OOONNR2 (E)200A TOP FID 60A MIERGRATED OC DISCONNECT AC DISCONNECT MAIN SERVICE PANEL 60A ARC FAULT PROTECTED AC DISCONNECT PA5$TNROUCX 1 StrIOg r/60A FUSES 240V NEMA-3R 6aoV '-4X of 20. m LL W o 6 240V VENA-92 s zW z t utiu6atmm oma,w V 0 v Eq 200A/2P 6 r-• G N of W o m.1z co O� FFA 04 ooz (E)LO DS G ,W o I I RnFRGRAIID REVENUE PASS THROUGH 1 String o o r-r O I I GRADE Mg 600V NEMA-4% I of 1S o a METER W C, I I a a Np>vOs°°I'om ¢O�gg� o �� I I I I I I U o m zo y w UIIITy SIRMGE EGGrt-c 0 a (E)GROUND ROD z z z z S NEC c Temp Condwtfill Termma175degC String Operating correction Design Max system Ground Wire m ^ y $ Wire Tag# Conduit Wuegty Wiregauge Wire type Temp Rating Wire Ampacity derate derate Derated AMPaCity rating Wattage Voltage ClrcuitAmps factor Current voltage Ground Size type w 1 Open Air 2 CAWG 10 PV Wire 90degC 40 0.76 1 304 35 5200 350 14.9 1.25 18.6 500 #6 SBC r � 2 1"EMT or PVC 2 C AWG 10 THWN-2 90 deg C 40 076 0.8 24.32 35 5200 350 14.9 1.25 18.6 500 #10 THWN-2 w 3 Open Air 2 C AWG 10 PV Wire 90 deg C 40 0.76 1 30.4 35 4680 350 13.4 1.25 167 500 #6 SBC 9 4 1"EMT or PVC 2 CAWG 10 THWN-2 90 degC 40 0.76 08 24.32 35 4680 350 13.4 125 16.7 500 #SO THWN-2 SHEET HUMBER 5 1"EMT or PVC 3 E AWG 06 THWN-2 90 deg C 75 0.96 1 72 65 N/A 240 42.0 1.25 52.5 240 #10- THv✓N 2 E7 6 1"EMT or PVC 3 E AWG 06 THWN-2 90 deg C 75 096 1 72 65 N/A 240 42.0 1.25 525 240 #10 1 THAN-2 ELECTRICAL NOTES: 1. AC disconnect switch shall be lockable,visible& 10. Adequate spacing must be maintained between any accessible without obstructions such as gates,fences or walls. plumbing sewer vents extending through the roof and the underside of the photovoltaic panels(6"minimum recommended). 2. All modules will be grounded in accordance with code 11. Pv equipment,systems and all associated wiring and and the manufacturer's installation instructions. interconnections shall only be installed by qualified persons 3. Notify serving utility before activation of pv system. (nec 690,4 e). 4. When a backfed breaker is the method of utility 12. Photovoltaic system conductors shall be identified and 'j grouped.the means of identification shall be permitted *; separate color coding,marking tape,tagging or other interconnection,the breaker shall be installed at the approved means.(nec 690.4b) opposite end of the bus bar of the Main Breaker. 13. Conduit is 3.5"-5"above roof deck,used Ashrae Data S. Work clearances around electrical equipment will be for conduit above 3.5"and below 12". Used chart 310.16 of maintained per NEC 110.26(a)(1), 110.26(a)(2)& the 2011 NEC in 750 c table using ambent temp. of 51-550 110.26(a)(3) 6. All exterior conduits,fittings and boxes shall be ow rain-tight and approved for use in wet locations per NEC $ 314.15. w w SN0'- tv 7. All metallic raceways and equipment shall be bonded wao oz (n N h O and electrically continuous. ;w g e 8. All pv equipment,systems and all associated wiring °s N i°o w and interconnections shall be installed by Qualified Persons. 9. The photovoltaic system conductors shall be identified a„= and grouped.The means of identification shall be permitted by separated color coding,marking tape,tagging or other U approved means.NEC 690.4(b) W 0 a ¢U¢ K tT Z J'y'y'tt CCK qyZ Y B] m j o N SMEEi NU"BE0. E8 CAUTION' SOLAR ELECTRIC SYSTEM CONNECTED PHOTOVOLTAIC DISCONNECT F LABEL FOR MAIN SERVICE OR UTILITY OPERATIONS LABEL FOR AC DISCONNECT CAUTION PHOTOVOLTAIC ARRAY DC DISCONNECT WARNING! POWER TO THIS BUILDING IS ALSO OPERATING CURRENT: 14.9 A THIS SERVICE ALSO SERVED SUPPLIED FROM THE FOLLOWINGtla.s OPERATING VOLTAGE: 350 V BY A PHOTOVOLTAIC SYSTEM MAX.SYSTEM VOLTAGE: 500 V SOURCES WITH DISCONNECTS ,r SHORT-CIRCUIT CURRENT. 15 A LABEL FOR MAIN SERVICE PANEL LOCATED AS SHOWN: LABEL FOR DC DISCONNECT&INVERTER "(� WARNING! 'o SJ,� PHOTOVOLTAIC POWER SOURCE ELECTRIC SHOCK HAZARD. OPERATING AC VOLTAGE: 240 V DO NOT TOUCH TERMINALS. MAXIMUM OPERATING AC OUTPUT TERMINALS ON BOTH THE LINE AND CURRENT- 42 AMPS LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. LABEL FOR MAIN SERVICE PANEL COVER LABEL FOR COMBINER BOX U3 PHOTOVOLTAIC ARRAY 0 AC DISCONNECT o`°� '12 Z o OPERATING CURRENT: 42 A CAUTION ��w o"�� OPERATING VOLTAGE: 240 V THIS PANEL HAS SOLAR&UTILITY 4 ?� oM mz POWER. BEFORE yow o� d LABEL FOR AC DISCONNECT (N)SOLAR ARRAY (N)INVERTER w o ALWAYS SHUT OFF BOTH m p) AC DISCONNECT FOR N o o om�r SERVICING. SERVICE POINT$ UTILITY OPERATION WARNING! UTILITY METERING ELECTRIC SHOCK HAZARD. LABEL AT THE MAIN SERVICE PANEL DO NOT TOUCH TERMINALS. r TERMINALS ON BOTH THE LINE AND SOLAR PRODUCTION METER w LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. LABEL AT PRODUCTION METER a LABEL FOR AC DISCONNECT WARNING:PHOTOVOLTAIC POWER SOURCE WARNINGI ELECTRIC SHOCK HAZARD. WARNING LABEL SHALL BE PLACED ON INTERIOR AND z IF A GROUND FAULT IS INDICATED, EXTERIOR DC CONDUIT,RACEWAYS,ENCLOSURES,CABLE ASSEMBLIES,JUNCTION BOXES,AND DISCONNECTS MARKING NORMALLY GROUNDED CONDUCTORS SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, i MAY BE UNGROUNDED AND ENERGIZED RACEWAYS,ENCLOSURES AND CABLE ASSEMBLIES EVERY 10 w=3 FEET(3048 MM),1 FOOT OF TURNS OR BENDS AND WITHIN 1 H LABEL FOR INVERTER FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING o ASSEMBLIES,WALLS OR BARRIERS MARKING PV CIRCUIT o 9 m CAUTION-SOLAR CIRCUIT DISCONNECT LABEL FOR AC DISCONNECT MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR PV MARKING CONTENT AND FORMAT 8o CONDUIT,RACEWAYS,ENCLOSURES,CABLE ASSEMBLIES,AND MARKING CONTENT CAUTION SOD t E r JUNCTION BOXES TO ALERT THE FIRE SERVICE TO AVOID CUTTING CIRCUIT r o THEM MARKING SHALL BE PLACED EVERY 10 FEET,AT TURNS AND w ABOVE AND/OR BELOW PENETRATIONS,AND AT ALL PV COMBINER -RED BACKGROUND o AND JUNCTION BOXES -WHITE LETTERING ' -MINIMUM 3/8"LETTER HEIGHT s„ rnuMeFx REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE -ALL CAPITAL LETTERS ENVIRONMENT(DURABLE ADHESIVE MATERIALS MUST MEET THIS -ARIAL OR SIMILAR FONT,NON BOL REQUIREMENT) �S�t�aCua^t�s�- .'° .EcoIa�en"Solace �S,�U44CvueDsa .��EcoIansten•Sola�^� Solar SnowMax Shade Angle Analysis 3.0 Shade Length'Calculations Contents 3.1 The following formulas solve for the Solar Snow Pad Up-Slope Shaded Distance If applicable • • �f Please note that.the calculations in the following pages'may not'be accurate,,examples of WJ i 2 T .o ersolar elevation angles or roof pitdi situations,the numbers are given for explanation 2,0, Terminology purposes only. 3.0 Shade Length Calculations 3.2 Figure 3.2.a below shows the geometry that determines the lowest porntthe'sun may be r 1.0 Scope before casting a shadow on the up-slope side of the Solar SnowMax Bar.Fig 3.2 a shows the 1 1This document outlines the steps taken to determine how much shade,in inches,is,present initial shading caused by.the SnowMax Bar Beam.(SnowNlax Angie—Roof Pitch)is the lowest outside the footprint of the Solar SnowMax during dayhght'hours in 30 minute increments.The maximum ele'vation,angle'the sun can'be.before initiaPshadmg octurs'Figure 3.2'16 below shade length,is only calculated for the Up-Slope side oft he snow guard because this system is shows the geometry that determines the lowest point the sun may be before the Solar used along Solar'Panel Eave edges.This information'wiil show.that there is minimal shading of SnowMax Bar Flange begins to shade the panels. the solar array,dunngthe peak operating hours throughout the year for various latitudes. Please note that the shade length-given in this analysis does not take the sun's azimuth into .0 W o m consideration "Please note that all dimensions are in inches' m w U o m iiHW omCR 2.0Terminblogy in0 0 { t \ ate "'o�Z 2.1 Sun-Elevation Angle(SEA):The peak.Angle(in degrees)between the sun horizon l` f 1 \, Y�W oo r-�d Tis ,S wow nm o LU 2.3 Roof Pitch(RP):The angle.of a given roof(in degrees) 2.5"Shade"from charts:Length of the shaded portion of the solar,array on the,Up,-Slope side of the Solar SnowMax*Outside of She SnoWMax Footprint.*The SnowMax bar should be located 'io r wmnP, F- entirely on the panel frame and suspended off the eave edge ( x w 2.6 Wthe diagrams showing the SnowMax Bar,the Solar SnowMax Bracket has been removed Fig 3 2.a for clarity The SnowMax Bar is shown in the following diagrams at the recommended mounting o distance from the Panel Frame. `;r Sfxn.Umiev. r U 4, � � C 4r+A AY4 1 J, o F N Q `Fig ii6.a SnowMax Bar Flange's what stops the snow,.the Beam is o m the feature that gives the SnowMax Bar its strength Fig 3.2 b y 1 2 " s1 30 SHEET NUMBER E9.1 Tel-a1 415 402 0502 j Fax,tt 415 402 0703 us;^41inkosolar coin j w'.nv pnkosolar cam, �l 4.- CarrnLWwpLPaa,ae f T,m m.p w w� it _ L+ - - pars QmY•0 dlz VxRnosJJ n y f 1#u _ - - � Nvtl tN 4.y - n •- -a + z s .s - va4gSY) Wr®prenRl Cell Type thiY-ny%'akne 255.256nm lb inch, __..-.......,,_._- '__' e y—y'�T{�'�� T3 M1ao`fie'u),„=..,- .::• .."�_ 60��01:1` � _: �r} - 'i,It'I-_li Pmc:aav y "+265G+99.,Tpm,r fad,],i9A6+L5i,n<hl> .R &on:Gbss N 3.:mmIF9nLa9snxsacnLw,•m .OLll O KEY FEATURES per, .n IM7F. www gm� Iisrcuw.rsn 6 le _ `o :rrac�t aaa paioii4�o;,ra*nar�Y µ _'t- =.cw'ales .% , ,.i:ay.c ges snGMm; +„� v, wow orn oY xlgL3 enclenoy. >°LLJC>moo`°' high motivle convel5ron vlhclencY Lep l0 13 84',611hl ovgh Anna va llvv 'A N C` a, n1calYlaeiwrrg lechnolaas' -- su 0 W t ry, s- 'toduk TYsa JYJS:cOP-•;9 JNM1V'i>?- a 1'V.L'al,,M .RIA_`yr>EQ! .KLLWI.. n0= � �U �+y Low-Un Pedermance. Adval d nlas) tl solos n>_=:.~_ h• = sT_c,_-'rPct' _LLs?c,.=wn,Y ancell svlf011 Irxl Vnng a0ow for rvRcellvni fAasSn•um Pov er Sma.) zuAtp 17N44 _•c_49Y.y ILltty :MO , 161,4. 29 ,p Iu vw MAh pellosnnncn m bw 68111 cnrvnonml.nll. CAadmAm,Ppvar Voila _ _ _ - _ f ~ gY L4'mP1 �b9V' y70V f,30 t,"T7 BY�y 305V� -6 Y 11Y ;,"a)BV,_:C5V X31 iV+:R1V�'a' U }+.ladmum Fow�Culrom--�4.j LOU C36A-_ LIN 6`SM _ S'_OA' 6U-A L:M a63A- L37A VA, W '000+i'+ir✓•I htag4 D^ocy'- - 31y ;34,T)- >N� Sae, ;'T„N '7J.h"'_� Ja4,;;_95.�V _-_381v. 3S=Y 0. IIH s'`an�samua Cv� 11.) am. 7IVR 076E 716. r^:aaM 1:1A 0 A S.Ti4 a- ?"A n• SeVcre WcaLher ResRler,ce: _ - - -_ "A4da'A•C$Ricl 5:C!' ,.. „-„_,E,{4 :.,', �IaOMr. 152�z:'S. _,1539..'. ;_ ,1599Y6� toslvtl la wllhslOnd m.Nmum p0)Ihvc I-dir10 UI 34001'.and neg.11ve -4— JIM - - - kw—iI of UCW'a. Operauq 7c,}:erY rt-;Cj •>G'C-.85 t: 141ann•um sysroMwtu14P� .. �. 10fA_VOCVU;',. le ,e ra—aae de—lfls.< -0+ta7C LINEAR PERFORMANCEMARRANTY 10 Year ProduelW®rentY•25Y--nem PororWn..nN l.l'4nYno4opemnf�g<rII�Pm�IaSvle Q�'OCn �. -. ,_ __- a.T .. ;,f�XYI .r •_ _,.1,.�. .. - ,_ ,_ u G�� P STC'd�itrraalance i000wrm= t�jCell Temperature 29`C :'"' n7n=i s o 'a � h N NOCT. �Jmdlance 8o0Wlm= ; Ambient Temperature 20'C' n I akn_i s „wind spaed I./, y x .'c•tt munurement-sJar;,ncele 3"A m ' - CAPTION READ SAFETY AND IA15'ALL,,IUN INSTRUCTIONS BEFCPE'>rING THE pRUDVCT, '_r JIn4o;.a'aI Co_ltd An ngl IG Iose,wd:p—f cA`.—Im-luded in Inly dasaoheal are sup)cct tr cManpx nnhau:nCt+ce- sxFET xUMBFx 10 S�l a r _ • e Single Phase Inverters for North America solar ®, ® �, . SEW)RA USJSESL•00A•US,SF6R00A-0S,SE6060A-US1 EL7600A US,',SEI000CA-US J SL.Id00A-US �. T_w 3C1460AU3 SE3800A US SESOdIA`VS SEEA04A USI 5F]GdTA`U$,S[1ROU6AUS 3 SESIiWA USt ~~� SolarEdge Single Phase Inverters . ,.,lArPw_:o��nt_ ,�� s" 3BPa AVR aJG -EW—{Y �8_ .ItCv�v, yry gm�8A s __3--T- W.. .._...v a Ila.AC Pnw^_%u.rP.! 334U' t 3150- &XA a 81'4 ` .2%: VA liU'i1?W _`3CY,U 'J For North America ' SE3000A-US/SE3800A•US I SE5000A-US/SE6000A-US SE7600A-US/SE1000DA-USISE1140OA-US J 0 ., , -- ._..._.4,�,Clnr-.._.—IZii•1-.--.1¢ 1 , 25 � SF _ ..._ 75 _ A �- _- ,illi u,Mr,n u�9,kk'�f].u4 PrfAr_oM,u a l;�i'cu^BI..'lLrc-h„IVxrv~~�•� _Ys �y.� --- v° • ftx.mum 0:,l`mw.�S3J•^.»..--_---AOW-tet. SlT7_,Y -G756�I,._GtW102.y —:535_n ' \yyn'd`� N:,`,OC uvx,ht ye,_-,�_ •�„_- ^y_ }2i cxi 2C�Vl70v� ,v _ __ � Ydc Ilxc trM+•CL,rnAr' ».k 9-....' ` 1!- ZLSi'•24.W(- :8 21 air iCSi' 1)' 319 AJ_� ` _.2.__�..............m,..�.-..,_ 1S t.L`v?UV _-_...__...�»__�._�'•Ul_5 c,7a.ri�}.-.._�a.,_� x .__ �I'. 1_�s i^Pv!:tr,�„ ,a,r Cu.nttT a•, f y Ad' ` mt,c.,.-Ibe•,l,�r<et�¢n� __-- _""-.,..-_____....,_.._._.....�._- Yom....,._..-___..._.,._._.___. __._..__-_...�_ - oLLLLI 00 � �'- hl.ur+num u,vrrrer ti:er'u-,y 1 97t�r�~ rv8: JD7 M1 1 'ifi 3 2: W r '6- Z i2rV W t Fl 1, I N� O ccKG2'rtrlCMtw:xy i X975 j 94 •I._v 97i� 9;5 2]i i Rw Orn1 of -` I _s�.,ll ..- 04 0Z ADDITIONAWATURC5 1 y p W R' O r y Su^M",e9 Cam'nu,ito a mom- 9Y 5 2S 3 YL.rM•,Ag9^e.ct ivrll yp 0r1.0 _ _ rleo-r 6;.dD Ulr,Art L32: _____ __ _ �..00r al_' _•__ __ w~O n tp 0 A T Il r.r.331wtUmxri-RIC 2Cle 54'411 { lu-ttw„ii9a.*'.+-4dwT+NulilYUE"':A^!>f•i!fUW+"I3i lstiCr[I' P _ pac 00-04 "@ STANOARO COMPLIANCE �() —1 -- \\,r.r, i ...__..�i�l;�lul:a�•iu.�r -vcIni].i La $! ____ _ON TAIIATIDNSPECIr ICATIi ' �INSAC¢u^a"tmrN„s+r/M1ritsrmleF _ 3,✓;mri um''7z ti,14\'G �i/i'uxn:rnumJR Ht U �:,+rM,r ac,..ut.ur r;,S+N•r`fl?., ! r ,e. -env m¢I I-ZUS-h,j,— W jjj�JJ���� U �4•w.in 5at4rf 3wIUh•_ `..._.....__ .12.5 a W 51 {Y}�'�! K 14 S.lI i]71/]Yt RS.'rt: �.._.. >3l5_3fn�1 ,r,n� CL - ^- Wm,M wrh;tictV_S_rlch ' 51:1'3 __I _ S!T J2�7 ` 6°•,call: 116%kfiT ._ w...,.,...,_ 1••v,U ._.m.�..p..._v. --�f„4,ai r+rraK3n.+r.R ��,I ,dic•ren..l r,-,In+n rylarakL•I, 1111 lav�'er 11>.w-__._�..�_�...�'-__..,_v.d..J.._e.a�.,..__..-`-___..._.... _..._._.._3..(L__.b.•1..�.-._...._�.»....._...r__...' e8a � K 'A'e_Alm Otitan�gT mpetmnr `�� 13—ii41.'}to,W(iRrc "oNy.4-�.-+ uYe.�-``uC'�•I.k-ham A Ylk✓Z.,i. F ” _ z z , gp,+J�is�M^niCC � • � y a (t5A•Gz flr,t Fl..'.(71.15'.;gAf4cr�iArAS,-C UfJ\-•,J+•TRj,11 F.-t•,C NWT"RLt NOS,7SF Afi 3� Y w o m Z SHEET NUM9rR El s®lar - ® v P solar _ e e T SQlarEdge Power Optimizer Module Add-On v P300; P350/ P404) P405 J P500 S®IarEdge Power Optimizer R� Pldd-- -PISO PsD� ,l(ar GR cou 3(f.,hkgh.p._, (lar 9E-cel{ ) Dorfidteld 'f'(for(hin Him �� i mW A.l j TA r0_,I ler mocW.l 1 r,.d 72 x01 medulesl f �" 7rcwl oawe.it : .hnrc.Hmr.V_ rr Module Add-On YPUT F_.._. ;__.___ m..r w__ _ __. _ _rt P'00 / P350 ! P404 ! P405 ' P500 ■ NacJlrpul Pa er^_ ��r 3"✓7 �1 350 "w� �', tos`� ic`s — `_`:v ; J ! Ahsuislo h1w,nnum hryvt 4o1L,Y✓ ice„ lsr at M;a✓,,1`+m r• dL 411 :Ji rA I l!i t,1t h11`iTU�":�n�p3r� P-•tE �py_cC�, }-T SAO�j T:75-oCi�l 12i-ltla jl_Vdc^ �� h1aU�ru.n Ca,f'rWus Wpal Curr✓ni(t".cl�l -" JD ( alJ T 1 10 1 All-__ ® Maximam Crly,lf'fty � _ 031 __ W<.t1,Ml or,u�r,.v__.,v.,._„_....-..v ..._____._....__._...____ :`fie „•,>�. _._.._-.... _..___.�.. .-- On,n,h3rrC_nln:av __{+_ ,._....11_ _..___-• _._._�-,�-.-•.-- OUiPUIDORING_Ott ATI_ON IPOMR OPTIMI2ERCONNECTED TO ODERAIING SOLAREDGE IAVERTER) _ _ M_ss;m_,R`II Out(r.: as _ 11,1pU!OU,.,R_1hG STAPIDFtY{POW[ROP,TIMILFR OISCONNECTtO EROM SOIARCOGE INVCRTCft OR SOLARCOGt II1vCRTCR OEF11, d w4.1 Lk.tl:nl Vuil r(J tour r\:v.lr D`ttmlce4u I _- _ _ _ o LL L1J O ■ STANDARD COMPLIANCE � � ���"�_�_�_�_ _��-����_���_�_"�"�"�"'�"���_� m w U p m M Lu CO'm Pa115 _ •__.__.._............................. Ye. ..__...-..�__......�._.r....T ' 2;8 N t'/3 O1Z y�j�vTfE'dY J I na iY.cy 11-AR L 2100 712"-G73-US t y O IJ.I O r' ^INSTfALAlION,SPECIfICAT10N5-_^~-�u -~ �1 y� �~----__� N O W O r _ N 13e,'+'r1T AIICs`.rd Sy.'rm V011an _" 1(D04 _Vac wi LU L __ _. .._._ .-_ __ `_ _.____— ";1E•.s2.:sJ;-'__ _ _T , -- _.— ogaq2 nova U,m.s`u•s 1\:'xLx Hl .28x IS2 x27 i/Sai4lx16d 1?Br15.s:3 i5x507xEE0 Imm fm, Oq TU Wf�)rrtuuluJmf Cs?I(S"����' 77R 717 _ t B1i,J2U5 J'/hr a'4= W 0 MbUYttnn f(sYnE� ,' ~' IY�+-1 NfirlAoF — {� d' SOLAREDGEINVCRTFR" THREE PHASE ^ At,r mJ n>Innr l<rfi*h 'I'314?f}iQPS@:-'V��_ 9_�� -r o {r l7rrne"OPnnt+Ta"sl Yf.:d4.P.0v I —'-al� „I�--. ria<Ynv,�1vH,�t1'Jr§U�IPOuel a4Ln1�!'<1 I �_'" s- �"��IzY�^�So �o� rlax,rntym ts:v.r prrt 5n 0 _ •.•.—.-.._;���^525tt _ LL 'r ._ 112;6 �_iN �3 P3r`I'{I�rmjS tt(u,f:MrllMytrrhp 14:2�.'J'I'!n:$"�—�T -- Y••y Y„^` 1!_ ��� 3: u..m,rnr.bi�*.v l+r�M+rr',trPY.rirN rrf•^.cv P,ir..,.., Z - Z J ' 8 m f.5„ r,;.0.;.1n1>K ,ehiv i•nf htr--r•,+a;? :,IJN,{.Ay}5frr,A l4 1hF Na;1>i,i.rl^.}-11•-1i,iA'•i. VdiVW.50)3f?C�E'.,[Ohl sNeETnurneert E11 .1 . M, Y A°HItU#'GRQUP LONPM7^ \\ N IMC IN7fGR/11ED OND),G;1S PRE-ISSEMBLED PARTS ' r r r -r 1 '1 r -r 1 _1• • 1 r 1 1 tan,5onwn a+r Frr=ss»aut<�anS opi.vaia e+»+x.sarauaroa 3ert _ r r 1 1 1 r - - .1 r' r 1 r r 1 r r -r - 1 ml;y'+auaa uma255t nrw 9idm9n9'i tnrridq.sgra�rxtmimai+i colye '�:,1NSEGJ2'ATfQ 60NDING' - ;v4+..ni�ateataq;+nM of 4..Ina 7mrcpe.n m raw..asst.7JGfG tiii. MIDQLAMI' - r _ I .1' 1 . '. r mk[AaiNM.Fmwn:,tG.11i.+w'n•ma.pG.An0Y1:1U,^.s7.la0ei'itUlfayetF � + V RS'ATRITY - I I I I 1 1 ONE PRODUCT MANY APPMI TIONS Q,edTyxn itsZvatm Q.vab taa(vara tla8sr.7 a'.1 mat.Q+snp.sw:lut. -. -+ �1,, 1 i 1 i' f t r> rt sr�svxc oz o.m<s;,e 7HAie us�mq a;ta.aF artotf aterv, :' INTc6RATE0'EONDINb �' I a�•. .I:'.. s �'� � ..t„ .�wq•.esanNS�a•+`a�as•e r�«v+lit-r+++:wt3�+a)uilrinmily<intivd<iarik zSPLICF'BAR� _ in.r2�lf A�4shis;.anai.rva#71.,ryiios.a<nit+�a)s.:r aeAi,C;sei.o7,�asnc _ AVA,l1ABltl.T:Y NATIONWIDE-',NETWDR K [hdne wn,.e...w+±:x'k ns++w Na ur..ty.+nst wa{.,'+r.;iai,cq - �J'`.: INTEGRATED BONGING _ _ rtp4ima our s.rui.+rrr.d[sanQiis�m[fig[1w+i(,M .aaynr pco.¢_ bs• .. - +vw(sFGy ini v.+.:5E<attt tt+.nwY.►nwa+aa tM t!Y3 +iw?.t at tavta , L=FdOT-w(7 DOLT _ uw.syr[ImcFrNaa...44at�l+tiu�pnnan}a{wx.:m/.cca-ar•aulwytiLLI s nrs5 4w MAyed.i�in rrs t 9s ih:s pmltv+usndasnoar«+ •. CO 0• _ . _,. _ �, �'"� .. _� _ _ _ DESIGN PLATI=ORMzAT YOUR'SERV)CE INTEGRATED DONDINGt _ [i.a..iUy a>lttiilmate.tal:t [�t�a trw zs�s•way hs L wauN,a .v/�•1�ICROtNV.EftTERsMOU I ;,. •a xe+r WIRE:dtANAGEMENT i )s Fwmld.t:n.-LaR ttrt aiimminet.ihi am<su If a +n 3 t kt - Iangttantsataf,mautn n,rysnr+,Sivv U2viXW6tinl�s.wi•j+allte.ana .::.:.�. �� .. FY?• fr(a1C 7ra!r.e<erYia?cai•Tres.aut.tn Jratyv+»rn,�uts LS Fn.�wilt .: ..�:. �,. - �,� aajoynh al$bj'.c.var.ap tryra!,+vkt a rio'ae p:Yie<e3 na.navea%Ntnt- • - i't "� r.iti+is7necul ud dutfaolartl�?idksam snirrr - Y UNIfitAG CUSTtER SERIE HIGHEST lEY£L:U �'RaDl1CT SUPPORT Gj 'tRtXxY�4?i0 SiltT;tHcp F1iGiNPfYY?7F �ArtFexCl}, � Qysseti'. K14•Rt !�F>•tEftLD QS1�V77' rt'tC.tLLfi+CC witYrtrd'L'F_. iQ¢'Lf ]y�tENia7t4(< ` TECHNICAL SUPP.OR•f PfRTwEO'QwuTY P1tOVlDER 6AF7KAHLf Y�ARRYINTY _ UiR,�d tay'aatca{'auFFarx tram(:a.utatvr -.- @tynr4rshr ar�i•.t�t>minztn�.nm.t+tr,;.:�5tr s.ta•Hft�Snty;m7rm4LninCh.t eni:?lnandaE - _ p,'acs rfitta 1i tan<'6 tieerasi+y iyxC rsra,u'�i.r6-{ar�WT;.`pu,.riDot3,LV.ane xnvbasx catpteeansana'±Nlt?3 rttsv< "` t �! ti '' n 1 4 1" 1:' 1'E i.rant vnr.d!-aatirr 1Krtty s'.:dresrme;as 9fi3A1_t ltp.};t0af ty�tsar maau W.gNiYa* ztin Ferar<e a:vu-n-M yaa ar.:ti<*Yaa, It t,(j I I I [ ) ) ndwi"a.§On 6U teaarts stamsrl t.ne s thr l .a s,na..ds Ax t4 fi u.antra Naa p}.luG of ft po.*atatirl SDT�Rr(wNT Mi)UN% <ernniat Eau *.a gnwty,4"it. lb—Lott 3Git nes ataoNbti r t es Ms iy a )ywt wo".mo= yaw.:Frrmtakiet,ami a(s).e vnnpty Fra. , a.d toxwim„int to oJa amt snwn.0 F+rt<.z. Y.arpyy zai a T"Ylat•wl d Mt h warnnry• PRUADI`YK MUMS IYFEIG DUAUTY AAO&IND SOLUTIONS MOXEDlT EN6'tNEMO E1CI;ain A404 SDP S SUPPLY CHAIPI. ..is.t,ar-armtw•�ts