Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
37937-Z
g�1FFtiC Town of Southold 1/13/2017 P.O.Box 1179 53095 Main Rd '4�` 4` Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38777 Date: 1/13/2017 THIS CERTIFIES that the building IN GROUND POOL Location of Property: 2705 Laurel Way,Mattituck SCTM#: 473889 See/Block/Lot: 121.4-12.4 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/4/2013 pursuant to which Building Permit No. 37937 dated 4/15/2013 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ACCESSORY IN-GROUND SWIMMING POOL, FENCED TO CODE, AS APPLIED FOR The certificate is issued to Fusco,Vincent&Fusco,Lisa of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 37937 06/19/2013 PLUMBERS CERTIFICATION DATED tho ed Signature SUFFna�r TOWN OF SOUTHO,LD BUILDING DEPARTMENT co W TOWN CLERK'S OFFICE Irv- .► SOUTHOLD, NY BUILDING PERMIT - (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 37937 Date: 4/15/2013 Permission is hereby granted to: Fusco, Vincent & Fusco, Lisa PO BOX 451 Mattituck, NY 11952 To: construct an accessory In-Ground Swimming Pool per DEC permit, fenced to code At premises located at: 2705 Laurel Way, Mattituck SCTM # 473889 Sec/Block/Lot# 121.4-12.4 Pursuant to application dated 4/4/2013 and approved by the Building Inspector. To expire on 10/15/2014. Fees: SWIMMING POOLS -IN-GROUND WITH FENCE ENCLOSURE $250.00 CO - SWIMMING POOL $50.00 Total: $300.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This•application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. -Sworn statement from plumber certifying that the solder used in system contains less than 2110 of I% lead. - 5. Commercial building,industrial building, multiple residences and similar buildings and installations,a certificate of Code Compliance-from architect or engineer responsible for the building. .6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and "pre-existing" land uses: 1_ Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features_ 2. Aproperly Eompleted application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy- New dwelling$50.00, Additions to dwelling$50.00, Alterations"to dwelling$50.00, Swimming pool $50.00, Accessory building-$50.00, Additions to accessory building$50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3_ Copy of Certificate of Occupancy-$_25 4_ Updated Certificate of Occupancy - $50.00 5_ Temporary Certificate of Occupancy -Residential $15 00, Commercial $15.00 Date- New a New Construction: Old or Pre-existing Building: (check once) Location of Property_ ����� / _-f j huc House No_ Street Hamlet Owner or Owners of Propert . l/},P1 cz k ro Suffolk County Tax Map No 1000, Section Block Lot Subdivision Filed Map. Lot: Permit No. � Date of Permit. l j7j Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted $ ,�� Applicant igna ure SUFFQ(,� Town Hall Annex ® �PGy Telephone(631) 765-1802 54375 Main Road ® :i Fax(631) 765-9502 to P.O. Box 1179 G Southold, NY 11971-0959 �fjQl �.a®� roger.richert(a)-town.southold.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE,OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: V&L Fusco Address: 2705 Laurel Way City: Mattituck St: NY Zip: 11952 Building Permit#. 37937 Section. 121 Block- 4 Lot: 12.4 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Bethel Elec License No: 1868-me SITE DETAILS Office Use Only Residential x Indoor Basement Service Only Commerical Outdoor x 1st Floor Pool x New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures Smoke Detectors Main Panel A1C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A1C Blower Range Recpt Fluorescent Fixture Pumps 1 Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks 1 Disconnect 11 Switches 1 Twist Lock Exit Fixtures TVSS Other Equipment: inground pool to include, bonding, 1-pool light, control panel, 1-GFCI circuit break 1-heat pump Notes: Inspector Signature: Date: June 19 2013 Electrical Certificate As c..lCJ F SO #a0 Uryo# 37F3'00 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION- FOUNDATION 1ST _ [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: 4! 72) :e�jj.aw DATE - INSPECTOR OF SOUTyolo TOWN OFBUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) REMARKS: DATE INSPECTOR 7WE, Ift. cou 'All -TOWN 'OF OU _NOL WING DEPT' 755-1802 IN' -CTI N [ ] FOUNDATION IST [ ] RO GH PLUMBING [ ] FOUNDATION 2ND [ ] SOLATION [ ] FRAMING / STRAPPING [ FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT.PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: Pg -40 J A(us i Td �itJ�L : DATE - INSPECTOR i �73 of SO(/ryolo ol�COU�,N� -TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION, [ ] FOUNDATION IST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ]3"16LATION [ ] FRAMING / STRAPPING [ FINAL ' [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION r [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: J =.2- DATE - - INSPECTOR, 37312 �o��OF SOUTy�Io TOWN OF SOUTHOLD BUILDING-'DEPT. , 765-1802 INSPECTION , [ ]- FOUNDATION 1ST [ ] RO H PLUMBING [ ] FOUNDATION 2ND [ ] I SUL N [ ] FRAMING / STRAPPING [�. FIN L [ ] FIREPLACE &-CHIMNEY [ - ] FIR TY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: a-ze ) LIZ DATE INSPECTOR �o��pF SOUjyolo " sa I.1, � TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION [ ] FRAMING / STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL ROUGH [ ] ELECTRICAL (FINAL) REMARKS: cp A6tA1t&�ftNw- -�o rill DATE 1 7/ 7kM INSPECTOR FIELD INSPEc14N REPORT DATE COMMENTS FOUNDATION(1ST) C N FOUNDATION(2ND) _Q - a ROUGH FRAM[NQ& y PLUMBING TeX, r INSUL•ATION PER N.Y. y STATE ENERGY CODE � 69-OZZ 1 L FINALGWQAIJI� 02/5 ADDITIONAL COMMENTS C U vim- O ® ��� l 0 e TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX: (631)765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. 3 7 �`3 7 Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined 20� Storm-Water Assessment Form �p Contact: Approved l �6 ,20 (-3 Mail to: v@ -cr Disapproved a/c �b� �'�`�a 911C,k Phone: Expiration /V (� ,20 �`7 X17 Building Inspector n E C E U LICATION FOR BUILDING PERMIT I..J APR " 4 2013 Date 3 Z , 20 INSTRUCTIONS a.This ap lic ' P ff be com etely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of lans,.accurp p an to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. �TATE LY„ "SCC 1 P ' I Cog OR (Signature of appl' t or name,if a corporation) ENCLOSE PO:t3VTO CODE QRON COAO- ETION --l0rive t, 1 AJ I �UT 4�,;E g � 11—I a I E (Mailing address of applicant) �3.� �,;�L;==s.E ;�F���:��. lir/l���. State whether applicant is owner, lessebj; gent;,architect',�ehgineer, general contra t electrician,plumber or builder PROVED AS NOTED -z>L); -Q-f' ` Name of owner of premises ' (As on the tax roll or latMdM(bUILDING DEP TMENT AT If applic nt is corp ration signature of duly authorized officer 765-1802 8 AN1 TO 4 PM FOR THE _ FOLLOWING INSPECTIONS 1 FOUNDATION-TWO REQUIRED (Name and ti of corporate officer) FOR POURED CONCRETE 2 ROUGH-FRAMING,PLUMBING, Builders License No. I-1 M 27 L-( 15— H STRAPPING, ELECTRICAL&CAULKING Plumbers License No. i 1 90 3 INSULATION Electricians License No. 2'8 3() — M TT6 U 8 4 FINAL-CONSTRUCTION&ELECTRICAL Other Trade's License No. MUST BE COMPLETE FOR C 0 ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW 1. Location of land on which proposed wgrk will be done: YORK STATE. NOT RESPONSIBLE FOR -S �11 U 1 ct fpho ST House Number Street NORM WATER RUNOFF ELE L PURSUANT TO cii �RT36-� ' CountyTax Ma No. 100 do F3 � Ill] 'o�lc OF THE TOWN' `" ` f Subdivision sion p ° OF ed Map No. Lot f 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy r V e, t-e -(� 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work—)o J', 'q CA 6 k (Description) 4. Estimated Cost 6�2 0 Fee T (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars y,l9 6. If business,commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any:Front ®' Rear �JO, Depth 'y / Height Number of Stories Dimensions of same structure with alterations or additions: Front 'q'Q j Rear Depth ,-,' Height Number'of Stories Z 8. Dimensions of entire new construction: FronRear q42,1 Depth Height Number of Stories 9. Size of lot: Front Z , / _ Rear �.3 Depth / 93,5r.� 10. Date of Purchase o Zo i o Name of Former Owner T e M G. i&5 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO 13. Will lot be re-graded?YES /NO • ill excess fill be removed from premises?YES NO 14.Names of Owner of premises Fuse Address;7765-,J--i ore 1M"' Phone Nok /7�z/?'F- 5-3-3 ' Name of Architect la hc.re�� tarD11 w�s�i un Address z7 3da;;" o'a''5��;�.A, tone N 6 b-y�'all Name of Contractor�jtQ �o��L�tT Address-261 b-r�1 O' TI one Nob d�- G�u r�Pr vets"Rey 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES- NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C.PERMITS MAY BE�REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property? * YES No—z * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OFAD being duly sworn,deposes and says that(s)he is the applicant (Name of individual sibfing contract)above named, (S)He is the c o n f-Y`C'l.0 I,}- o (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this "'L day of p 20 01 otary Public BRITTANI n, „SKI Signature o pp 1c "NotaFYW T7ANY K SIO do�tyePublic,State of ew Yom Qimlifled in Suffolk Coun My CommissND OX062698U- 016' My CommisSlon Expires Aril no Apr 041310:06a 718 463-4812 p.3 n AM NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION Facility DEC ID 1-4738-04137 PERMIT Under the Environmental Conservation Law ECL Permittee and Facility Information Permit Issued To: Facility: VINCENT FUSCO FUSCO PROPERTY 2705 LAUREL WAY 2705 LAUREL WAYISCTM 1000-121-04-12.4 PO BOX 451 MATTITUCK,NY 11952 MATTITUCK,NY 11952-0451 (917)478-5337 Facility Location: in SOUTHOLD in SUFFOLK COUNTY Village: Mattituck Facility Principal Reference Point: NYTM-E: NYTM-N: Latitude: Longitude: Project Location: 2705 Laurel Way - Watercourse- Laurel Lake Authorized Activity: Install a swimming pool and construct a pool fence. All authorized activities must be in strict conformance with the attached plans stamped N-YSDEC approved on 12/3112. (JRP) Permit Authorizations Freshwater Wetlands -Under Article 24 Permit'lD 1-4738-04137.00001 New Permit Effective Date: 12!3/2012 Expiration Date: 12/3/2017 NYSDEC Approval By acceptance of this permit,the permittee agrees that the permit is contingent upon strict compliance with the ECL, all applicable regulations,and all conditions included as part of this permit. Permit Administrator- GEORGE W HAMMARTH, Deputy Regional Permit Administrator Address: Af NYSDEC REGION 1 HEADQUARTERS SUNY @ STONY BRQUKJ50 CIRCLE RD STONY BROOK,IVY 11790-3409 Authorized Signature: �'� 5 %fir ` �' Datefi-02 Distribution List Habitat JACQUELINE R PASQUIN-1 Page 1 of 7 1 J 1 T -vvn of Southold - Chapter 236 - Storm mater ManaBement �g SWPPP - Storm Water Pollution Prevention Plan Assessment Form GENERAL INFORMATION: (All Requested Information is Required for a Complete Application) AP UCAN 1NA E: Owner-Agent-Co - nsuhan Con actor or her(Circle One) Property OWNER:(ff Different than Applicant) i Add res - ' 1T I Address- L Telephona�&-A Fax Telephone F V: P 35-2 6 3t 1 s' 3 r- X11 3- 6 E-Mail: r ? 1 E•Mail: 1 l'e_ �f J - i Property Addresa:z-703,,,r 0. ; Brief Description of Constracdon Activity,Proposed Structural BMPs,Soft , Stabalization BMPs,Project Scope and/or Sequence of Construction Activity ; S.0 7 M. Dt�W eba t � IWoo le Addtiond NDes as Nemec)) i Name o andlor Contact Person Responsible for Implementation of SWPPP: _ P f _ l'\ Address• lAi 1 cc__ - Imo 'P�l rrJ�( �__ �4�_ 1-¢�a1s.�L=�------ Tele �1 —3S2 7 31 F . i f E- a . o cQ --------------------------------------------- I ' Name of Persons Responsible for Installation 6 Malntenanca of Erosion Control Practice: i Ce. -------------------------------------------- Ad --------------------------Ad ' 6� ff--�r� ted- Z® Q q Tf er -------------------------------------------- Tel plrone#:I — E-Mail: a ---------------------------------------------- i i Total Area of All yf, 1 Total Area of Land Clearmg �d8 t7• ProjectParce)s- _0 and/or Ground Dislurbance --------------------------------------------- (S F!Acus) (S F!Acct) f Project Duration: startEnd ---------------- -----------------------.------- (Anticipated) Z/5-- Datc: E� / Dale: (rAvnbal dCotenr'�r eeys) Will this Project Disturbe five 5 or More Acres at Q Any OneTime During the Proposed Development? Yes No -------------------------------------------- UYES:PleaseAnswerthe FDIIGWlngl _.._..._,.._.,....-,._..._....,_�____.........-.___._---_"_.`---__-- a. Does the Applicant have a Qualified Inspector On Q ; Staff To Conduct the Required Inspections? es,/ No ; b. Does the SWPPP Indicate How Frequently the Site I /1 List the NAMES or description of all Potentially Impacted Waterbodies andlorwetlands: Inspections will Occur and for What Period of Time 7 $s-� No c. Does the SWPPP Adequately Identrfy All Temporary Q U i and/or Permanent Soil Stabalization Measures? Yes • No ------------" "-` -""` '"` ---- d- Does the SWPPP Adequately ldenlifyaComplete = 0 ------------'---- ---"------" -- ----- Project Phasing Plan? Yes No Status of Impacted Waterbody:(eg_TMDL,303(d)Usted,Impaired-) e. Does the SWPPP Indicate Additional Site Specific = ® i Practices that Will be Utilized to Protect Water Quality? Yes No _ f. Has the Applicant Submitted a Completed DEC Notice Type of Impacted Waterlwd_(eq.Lake,Creek, _ - y Bay.Pond,Soured,Freshwater Wetland_.) Of Intent and SWPPP Acceptance Form for Review i by the Town of Southold? as No STA'IT OF NF.W YORK, 15100y t-'Mf) r Otate Ul'Imew YorK I COUNTY OF...........................................SS No.01 BU6185050 j Qualified in Suffolk COI.lnty ---...being drily sworn,deposes an spays is e%s E tis° s p�} ` That I,. .. .. ._. � ��� he {lie a �rt'f t ............(Name of individual signing Document).._.._....- ' Andthat he/she is the ......................................... .................................................................................................-..........--•- IoUrnrptfce, Owner and/or representative of the Owner or Owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all stateinents contained in this application are hue to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed herewith. 1 Sworn to before me this; - --{� ---------.-•-----day of Notary Public: V.!`fl......,, .-.... ... (Signabae of Applicant) SWPPP Assessment FORM: 03-12 I• SO�j�yD! MAY 2 1 2013 Town Hall Annex Telephoige d§pj)765-18 54375 Main Road T CC631 R63 P.O.Box 1179 • O ro owri:SO e Southold,NY 11971-0959 Q IyC�IrI�,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION 3 REQUESTED BY: Date: Company Name: 13,P_UAe-.I E_1 ec-k--r c. Name: V , 0-4p- u,r 0 License No.: ( $ 6 g Address: 1-337- 8 U I n AVS _ I- vl br-no k Phone No.: (0 3 I) g 5 D - C_SS 5 JOBSITE INFORMATION: (*Indicates required information) *Name: V 0 n G e,n T 4 L_i S c, rL i S d *Address: 29 0 5 Laurer � 1 VQ!j *Cross Street: by "V-p- *Phone No.: Cq I -1 L-F 7 R _ 533 R Permit No.: 3 '7 ?5-'7 Tax-Map District: 1000 Section: 12( Block: L _ Lot: f Z. l *BRIEF DESCRIPTION OF WORK(Please Print Clearly) C oflsAry Vrt r-©uhA p ©01 w ,A-k (Please Circle All That Apply) *Is job ready for inspection: YES! NO Rough In Final *Do you need a Temp Certificate: YES/ NO - Temp Information(it needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of f Meters Change of Service Overhead Additional Information: VOW r- DUE WITH APPLICATION - D MAY 2-8 2013 B2-Request for Inspection Fo BLDG DEPT �� TOWN OF SOUTHOLD 3 ? 3 U&ft@W O �_ Hams M o 0 0 oLu�77^ i Posta � ry Certified Fee . % �® Postmark M Return Receipt Fee t} '+ (Endorsement Required) Ma , /' t Restricted Ddlivery Feb p (Endorsement Required)--•- - r���r 3 Total Postage&Fees $ �� 3 Sent To O Street Apt. o.; L r`- or PO Box No. ..q�._...1_ _____________w--W--__ City state:Zlt'+4- -- D • e --COMPLET-ETHIS-SECTIONOiVDkLIVERY ■ Cot plete items 1,2,and 3.Also complete A Signa re item 4 if Restricted Delivery is desired. ■ Print your name and address on the reverse X` qqL'__�EOI Addressee so that we can return the card to you. B. ReceivedPrin✓ted ame) C. D to of elivery ■ Attach this card to the back of the mailpiece, _713 or on the front if space permits. i �h �j D. Is delivery a•dress different from item 1? 11 Yes 1. Article Addressed to: If YES,enter delivery address below: ❑No \is r ,Ca_iN+4-L—i5c� FU6W �o e::O x qS- (/IM l ' A N y 3. Service Type / }(Certified Mail ❑Express Mail ] 1 ❑Registered O:Retum Receipt for Merchandise ❑ Insured Mail ❑C.O.D. 4. Restricted Delivery?(Extra Fee) ❑Yes 2. Article Number. . (Transfer fromise'rwceiha 6/)ti l k i l t [7 Oi10 11;,��1, Op'1,;1�61. �73 i PS Form,3811,February 2004 Domestic Return Receipt 102595-02-M-1540 — i '— '- - I i - ' - - --- - -- - - -- - - -- - - 7154 Date File# I TOWN OF SOUTHOLD COMPLAINT REFERRAL FORM Location of Complaint:atios Lt r' CTM Property Owner: `��' �0ALPqk Ec,56�- Phone Address: NATURE OF COMPLAINT: ACTION TAKEN: Optional: Complainant: 6/r 49 By Phone Mail In Person_ Address Phone: Report Taken By: Date Date Referred to Code Enforcement: ----------------------------------------------------------------------------------------------------------------- ° CODE ENFORCEMENT REPORT SITE INSPECTION REPORT/DATE: ACTION/DATE: *pF SO!/l�ol Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G � Southold,NY 11971-0959 COUNTi BUILDING DEPARTMENT TOWN OF SOUTHOLD TOWN OF SOUTHOLD BUILDING DEPARTMENT VIOLATION NOTICE TO: Vincent & Lisa Fusco DATE: July 8, 2013 PO Box 451 Mattituck, New York 11952 PLEASE TAKE NOTICE there exists a violation of Southold Town Code Article IV, Low-Density Residential R-80 District and New York State Code Appendix G, Section G105, barrier requirements. At premises hereinafter described in that: According to State and Town code, a swimming pool must be fenced The premises to which this ORDER TO REMEDY refers are situated at: -------- 2705 Laurel Way, Mattituck. SUFFOLK COUNTY TAX MAP #1000-121-4-12.4 Failure to remedy the conditions aforesaid and to comply with the applicable provisions of law may constitute an offense punishable by fine or imprisonment or both. . Jr,—, �'- �� Authorize Si natur Southold Town Building Department �o�$ntFni��OGy P.O.Box 1179 Permit#: 37937 53095 Main Rd Southold,New York 11971 Permit Date: 4/15/2013 (631)765-1802 Expiration Date: 10/15/2014 Parcel ID: 121.4-12.4 BUILDING PERMIT RENEWAL LETTER Dated: 1/6/2017 Applicant: Deiter Specht Location: 2705 Laurel Way,Mattituck Work Description: IN GROUND POOL construct an accessory In-Ground Swimming Pool per DEC permit, fenced to code l A FEE OF $125.00 IS REQUIRED TO RENEW THIS BUILDING PERMIT. Owner: Fusco, Vincent&Fusco, Lisa Address: PO BOX 451 Mattituck,NY 11952 The permit listed above has expired. No work is permitted or authorized beyond the expiration date. Please submit the above fee made payable to the Town of Southold. Mail to the Town of Southold Building Department, P.O. Box 1179, Southold,New York 11971 THANK YOU, SOUTHOLD TOWN BUILDING DEPT. 1 li I SURVEY OF PROPERTY A Z` LAUREL S7972,So e \ co�N�- TOWN OF S®UTH®LD SUFFOLK COUNTY, MY 1000-121-04-12.4 ,,,� 3 \ \ o� PVE• SCALE. 1'=30' WPB ' �' yF \ S AUGUST S, 2012 /apo 6'p SEPT. 11, 2012 (PROP. POOL) Op. co � N ro C Y a 00 co � �4� �" Ftitoy cp A � �. �Q j 6• iz TERMS r "TIONS OF PERM�TN.0. 4 1s. ti 44.s '�pFS�p , DATE3 ` 137 I r C-i / 10. 61) Nfits - �• o ,,. Q y� �...e�1 10. ee R�RF s,oo' ` LtS ;tee`' �? ANY ALTERATION OR ADDITION TO THIS SURVEY lS A VIOLATION LIC. NO. 49618 OF SECTION 72090F T,;1F_ NEW YORK STA 7E EDUCA 77ON LAW. ECONI C IURMEYORS, P.C. EXCEPT AS PER SEC77ON 7209—SUBDIVI5ION 2. ALL CER77FICA77ONS (631) 765-5020 FAX (631) 765-1797 HEREON ARE VALID FCn4 THIS MAP AND,COPIES THEREOF ONLY IF P.0. BOX 909 AREA-20,031 SO. FT. SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF THE SURVEYOR ■=MONUMENT 1230 TRAVELER STREET WHOSE SIGNATURE APPEARS EREON. • =PIPE SOU TNOLD, N. Y. 11971 12-229 �1 y FINISHED GRADE Q // �O J / 4"CONC N /� � SLAB O LU 4"PIPE 000000 Z\U�/ 0 EM 000 \/ 31MIN 4'0 Z 3'MIN \/ COLLAR LEACHING SECTIONN COLLAR \� Q F V ':S 0 J /may GROUNDWATER 10/ \ Xz QJJ p ) \\ \ �pC) BACK FILL MATERIALTO BE CLEAN SAND AND GRAVEL LEACHING POOL DISTRIBUTION POOL FLUSH INLET LEACHING BASIN DRAINAGE CALCULATIONS STORAGE REQUIRED 350 GAL APPROXIMATE STORAGE PROVIDED p�, a, (1)4'0 x b'DEEP POOL= (c)) 8.75 x 6'=52 5 CF(x 7 48 gallons/CF)=3927 GAL �° Q�`� T `T� \t it Labcrew Project: �•• Spect-Tacular Pools, nA\� ���� No. f}f38�1� Engineering, P.C. Drain Cals.for:Fusco Q% 273 Hawkins Avenue 2705 Laurel Way,Mattituck N.Y. 3661 Horseblock Road Ronkonkoma,NY 11779 Building R Tele:(631)676-4881 Date: Medford,N.Y.11763 Labcrew@optonline.net 3 27-2013 1 1` INSTALLATION COMPONENTS " INSTALLATION " INSTRUCTIONS' f (Not Provided) TM "MERIT-° SERIES HEARTH PROD UCTS° • 42"Wood Burning Fireplaces P/N400,047M REV. B 12/2008 " Chase Termination (square) " 631.51 FTF8-CT2 Attic Shield Assembly 631-67 FTF8-FSAS NIC?DEISy , _; O r :. RDI-42 HCl-42 RDI-42-H HCl-42-H ' Chase Termination - `r .Chase Termination •, Cold Climate Kit -H7412 CCK-HCRD (Round) 631.45 FTFB-CTDT (Square) 631-48 FTF8-CT1 This installation manual will enable you to obtain a safe,efficient and dependable installation of your fireplace system.Please read and under- 1 stand these instructions before beginning your installation Do not-alter or modify the fireplace or its components under any circumstances.Any modification or alteration of the fireplace system, i including but not limited to the fireplace, chimney components and accessories,may void the warranty,listings and approvals of this system and could result in an unsafe and potentially dangerous installation. IMPORTANT! TO ASSURE PROPER ALIGNMENT OF GLASS DOORS: f elf INSTALL THIS FIREPLACE IN A SQUARE AND PLUMB CONDITION, USING SHIMS AS NECESSARY AT SIDES AND/OR BOTTOM.' - - _ - NATIONAL We-`uggest that our woodburning hearth INSTIIT�UTE products be installed and serviced by INSTALLER: Leave this manual with the appliance. / d l professionals who are certified in the U.S. CONSUMER: Retain this manual for future reference. by the National Fireplace InstituteP(NFI)as t' NFI Woodburning Specialists or who-are NOTE,DIAGRAMS&ILLUSTRATIONS NOT TO SCALE 'j A certified in Canada by Y Tested& Poruand i ,S Listed By Oregon USA OMNI Report No.116-F-52-2 The manufacturer reserves the'right to make changes at any time,without notice,In design,materials,specifications,prices and also to discontinue colors,styles and products Wood Energy Technical Wood Energy p Consult our local distributor for fireplace cod information _ CERTIFIED Technica►Tratning C us y p p' wwwMicertinedorg Training (WETT). -- ^• "< < OMNI-Test Laboratories,Inc. r -L. ENNOX rM % _ HEARTH PRODUCTS Pfinted In U S A o 2007 by LENNOX HEARTH'PRODUCTS 1110 West Taft Avenue P/N 850,047M REV. A 12/2008 Orange,CA 92865 j TABLE OF CONTENTS 2.Always check your local building codes The The manufacturer is not responsible for any INSTALLATION COMPONENTS installation must complywith all local,regional, smoking or related problems that may result Safety Rules .... page 2 state and national codes and regulations. from the lack of adequate combustion air.It is The following Items are available for use in the (FBK 2W M°d&Only) Tools and Building Supplies............ page 2 the responsibility of the builder/contractor to installation of this appliance. Precautions .................................... page 3 3. These fireplaces must be Installed with ensure that adequate combustion air has been Security Chimney's FTF8 (8"Inside diameter) provided for the fireplace Introduction................................ page 3 Chimney System only.These systems are in Clearances/Height Requirements. page 3 tended for use in any application where a 13.DO NOT use a fireplace insert or any other O Chimney System ...... . . .. page 3 traditional masonry type fireplace would ap- products not specified herein by the manufac- Assembly Outline .. ......... .. .. page 4 ply.The chimney system must always vent to turer for use with this fireplace.All gas log sets Chimney Section 631_10 FTF8-12 Location of Fireplace page 4 the outside of the building must be operated with the damper clamped 631-13 FTF8-18 ..... .. 631.14 FTF8-36 open, Including unlisted"vent free"log Sets. Forced Air Blower Kits Assembly Steps... .... ...... ........page 5 4. To ensure a safe fireplace stem and to Listed "vent-free" to sets may be operated 631.15 TFB-18C -Single Speed BOL85 FBK-100 P Y 9 Y P Canadian 621_92 FTFB-18C _Variable Speed BOL85 FBK-200 Preinstallation Notes .. ........ . page 5 prevent the build-up of soot and creosote, with the damper closed. Firestop Spacer(30°) 631-32 FBFS30-2 Chimney Section 621.93 FTFB-36C Clearances ............ ........ .. page 5 Inspect and clean the fireplace and chimney Installing the Fireplace ..... ... page 5 prior to use and periodically during the heating 14."Smoke free"operation is not warranteed r. Fireplace Specifications .................. page 6 season. nor are we responsible for inadequate system draft caused by mechanical systems,general Framing Specifications.. ... ..page 7 5. Use solid fuel only. DO NOT use artificial construction conditions,Inadequate chimney Y Installing the Chimney System . ...page 8 wax based logs,chemical chimneycleaners or heights, adverse wind conditions and/or un- < 30°Offset through Floor/Ceiling......page 9 flame colorants in your fireplace. usual environmental factors or conditions be- Ten Foot Rule Summary.... ..... page 11 yond our control. Multiple Terminations . ......... page 11 6: DO NOT use charcoal or coal under any Y ° g 631_38 Fa;Z circumstances. 15.Never,under an circumstances,Install a Flashing 631-39 F8F Chimney Component Calculations... page 11 fireplace,chimney component or any acces- offset/Return Special Offset Instructions..............page 11 7.NEVER use gasoline,gasoline-type lantern sones,that has visible or suspected physical Package(301) 631-22 FTF8-ES30 Vertical Elevation Chart....... .......page 12 fuel,kerosene,charcoal lighterfluid,or similar damage as a result of handling or transporta- Offset Calculations............... .... page 12 liquids to start or"freshen up"a fire In this tion These items should be inspected by your Outside Combustion Air Kits p g (with duct) 811.87 FOAK fireplace. Keep any flammable liquids a safe distributor or qualified factory representative (without duct) 811.88 FOAK-LD Offset Elevation Chart . ........... page 13 distance from the fireplace. to ensure safe condition When in doubt,con- ® t t® Installing Offsets . ..... ...........page 14 suit your distributor. 00- ° Optional Equipment Considerations. page 14 8. NEVER leave children unattended when Forced Air Kits.............. . . page 14 there is a fire burning in the fireplace. 16. For additional safety considerations and Combustion Air Kits ........ ..... .. page 15 complete operating Instructions, refer to the Gas Line Connection................. .. page 15 9•Always keep flue damper open when heat is Care and Operation Manual provided with the Stabilizer 631-25 FTF8-s4 present in the fireplace fireplace. Chase Termination 961-20 FTF8-CTT Vent Free Appliances.................. page 15 Glass Doors ......... . . ........... page 16 10. Before servicing, allow the fireplace to TOOLS AND BUILDING SUPPLIES O Cold Climate Insulation.... . ... page 16 cool Always shut off any electricity or gas to NORMALLY REQUIRED Fireplace Finishes page 16 the fireplace while working on it This will P ••••••••••••••• ••••••• P 9 Combination Mantels and Trim . ... . prevent any possible electrical shockor burns. Tools should Include: ............. page 16 Offset/Return Elbow 631_28 FTF8.OR15 7! r 9 Phillips screwdriver Hearth Extensions.. .... .. ........... page 16 11. This fireplace is not intended to heat an Hammer Firestop Spacer(Flat) 631.311 F8FS-2 Finish Requirements .......... ....... page 18 entire home or be used as a primary heat Saw and/or sabersaw r'- Installation Components........ page 19 source It is designed to ensure homeowner Level comfort by providing supplemental heat to the Measuring tape Round Termination 631-42 FTF8-CTD Plumb line This manual is part of a set of two supporting room. Electric drill and bits EMU this product. Refer to manual 875,039M for Care And Operation Instructions. 12.Always ensure an that adequate supply of Pliers replacement combustion air from the outside Square of the house is accessible to the fire to support Storm Collar 631_59 FSC IMPORTANT: PLEASE READ AND normal combustion Fireplaces consume large Building supplies UNDERSTAND THESE RULES TO volumes of air during the normal combustion Framing materials Chase Termination 961_22 FTF8-ATT FOLLOW FOR SAFETY. process In the event the home is tightly sealed Wall finishing materials y with modern energyefficient features,the o Locking Band s31_so FLB P Caulking materials(noncombustible) _ 1. Before starting your fireplace installation, tional combustion air kit may not provide all Fireplace surround and hearth read these installation instructions carefully to the air required to support combustion. extension materials(noncombustible) be sure you understand them completely and in entirety. Failure to follow them could cause a fireplace malfunction resulting in serious injury Shipping Weight 188 lbs. and/or property damage 2 NOTE DIAGRAMS&ILLUSTRATIONS NOT TO SCALE 19 c - The sum of all"R values"is:.70+.10+.038 PRECAUTIONS Note: Illustrations shown reflect "typical" +.10=.938 installations with nominal dimensions and 1 1 1 ' • • ' 1 Wall Shield Required Note:These fireplace systems are not difficult are for design and framing reference only. Where Less Than 12" - This would NOT be an acceptable combination _ to install.However,in the interest ofsafety,itis Actual installations may vary due to indi- �36^ recommended ualifiedor vidual design references.However,always ` 1' •' ' 1 ' of material for the hearth extension since the q 9 P Y total calculated"R value"of the materials used certified"tradesman"familiar with commonly maintain minimum clearances to combus- 5 vz" acce ted Fre lace installation and safer tech- tible materials and do not violate an s e ' is under the required "R value" of 2.33. An P P Y Y P additional layer of insulating materials must niques as well as prevailing local codes. cific installation requirements. THE LIMITED WARRANTY. 36" be used. The most important areas of concern dealing These fireplaces have been tested and When complete these fireplace systems con- Note:Also see NFI Certification Manuals for with the installation of factory-builtfireplaces are listed by Omni-Test Laboratories (Report sists of four basic"sub-systems": clearances to combustible materials,proper as- No. 116-F-52-2 to U L. standard 127. expanded explanation on calculating "R vol- z^ ) ' c semblyofcomponentparts,heightofthe chim These units are intended for installation 1. The Fireplace ues"when multiple materials are used. p B Max.Thickness Of Hearth Extension When ney system,the proper use of accessories sup in residential homes and other buildings 2. The Chimney and Termination D C Circulating Models Are On The Floor plied by the manufacturer and the techniques of conventional construction including 3. The Optional Glass Doors A WARNING: employed in using finishing materials applied to 1 �HEARTH Figure 5o 9 9 PP commercial, not in mobile homes. 4. The Optional Combustion Air Kits - Figure 48FIREPLACE THE -, thewall surrounding the fireplace,hearth exten- 5. Optional Cold Climate Kit (Mandatory in SION MUST BE SEALED WITH ANON- Secure the hearth extension to th-e-floor to sions and wall shields.Each of these topics will TheseefirePflaces have been tested for instal- Canada) COMBUSTIBLE MATERIAL. be covered in thorough detail throughout this lation in Canada to ULC-5610. For installs- Calculating Minimum Thickness if Multiple prevent possible shifting. manual.Please give each your special attention CLEARANCES AND HEIGHT Materials are Used g Y P tions in Canada,the chimney clearance to FINISH TO YOUR TASTE as you progress with your installation. combustibles must be 2 inches and the REQUIREMENTS WARNING: INSTALLING ` • Cold Climate Kit must be installed At times it is important to know what EXTENSION •1 1 1 INTRODUCTION The fireplace may be placed on or near normal combination of materials are acceptable forThere are a wide variety of"finished looks"for use as floor protection. The "R values" areLATING FIREPLACE MODEL, FIRE- P these fireplaces,from formal wall decor with General Information These fireplace systems are designed for combustion air kit, construction materials*.P PLACEMUSTRAISED 1 installation in accordance with the National firestop spacer and roof flashing (not chase Used to determine acceptable combinations of elaborate mantels to rustic wood paneling or These fireplaces are conventional radiant heat flashings)may be laced direct) on or against materials because"Rvalues"are additive where HEARTH 1 1 1 warm brick facings. p Fire Protection Standard for chimneys,fire- 9 ) Y P Y r and k values are not. BOTTOM 1 �' fireplaces with standard bar grates, optional places and solid fuel burning appliances; normal construction materials The chimney . Only noncombustible materials like stone,tile, outside combustion air kits and optional deco- NFPA 211 and in accordance with codes requires a minimum 2"air space clearance to y rative lass doors. combustibles. The fireplace outer wrapper 9 such as the BOCA Basic/National Codes,the "R value"=1/k="r"xthickness of material brick,etc.,may overlap the black front facing. � requires a minimum 1"air space clearance to ` used Do not extend these materials beyond Standard Mechanical Code and the Uniform Y The"C"models are designed as heat circulating Building Codes. combustibles. A combustible mantle may be facing and into the firebox area.Be sure not to fireplaces and may befitted with accessoryfans. g installed 12"above the opening of the fireplace as Example: Given that the required"R value" interfere with the installation and operation of per NFPA 211,Section 7-2.3.3. In Canada,the for a suitable floor protector used must be I I glass doors or block the upper or lower grilles. minimum is 18"above the fireplace opening. equal to or greater than: I __-- Seal all joints between the black facing and wall TYPICAL INSTALLATION — surrounds to prevent air intrusion. Use non- The minimum installed height of the completed "R"=rL x TL=2.33 x 1"=2.33." combustible caulking material only to seal the fireplace system is 15'0".The maximum height 7112" black metal facing to the surround material on is 60'0". If it is desired to elevate a marble hearth ex- the finished wall. ' The fireplace and chimney system must,be tension to a level of 5"or more above the floor Max.Thickness of Hearth Extension when .enclosed when installed in or passing through surface. What combination of noncombus- Non-Circulating Models Are On The Floor Combustible materials may project beyond the Blower Kit P 9 9 sides of the fireplace opening as long as they (Optional) a living area where combustibles or people May tible materials can be used to accomplish this? Figure 49 are kept within the shaded areas illustrated in come in contact with it.-This is important to 9 If common brick is used so that the 3 1/2" Figure 51. prevent possible personal injury or fire hazard. dimension is the height,"R"for the common WARNING: P ; rerminaChimneiiond i Terminaiiond- For questions, please call your distributor or brick becomes: HEARTH 1 ' • 1 the manufacturer.Special restrictions apply to Combustible � brick 1 BLOCK , Materials the front and facing of the fireplace and nearby Allowed In Fireplace ui walls(See pages 16,17 and 18). "R"M=rM x TS= 0.20 x 3 1/2" =.70 INLET GRILL ON CIRCULATING MODELS. Shaded Area "Safe Zone" 1^ i Outside I CHIMNEY SYSTEM Using 1/2"of mortar to set the brick,"R"for Combustion outside the mortar is calculated as follows WARNING: ' HEARTH as° Air(Optiodo mortar 1 •I 1 ' ' " I nal) Air Kit ombustion These fireplaces are designed and code listed "R"M=rM x TS= 0.20 x 1/2" =.10 OD1zQ (Optional) for use with Security Chimneys FTF8 chimney System only. Always use Security Chimneys RAISED 1 HEARTH FTF8 chimney components with these Next,a 3/4"marble slab set in 1/2"mortar cov- , 1z^ Min.Distance To Y MUST • fire- EXTENSION1 1 BOTTOM Unprotected Side Wall places. Do not modify or alter these compo- ers _ becomes: marble "R"for the marble and mortar 1 t �� nents as this may cause a potential serious marble Figure 51 hazard and void the Warranty. "R"M=rM x Ts= 0.05 x 3/4" _.038 Radiant Model Shown Circulating Model Shown *Construction Materials: mortar "R" =r x T = 0.20 x 1/2" _.10 _ •framing materials paneling M M s Figure 1 •particle board •flooring •dry wall •etc. •plywood 18 NOTE DIAGRAMS&ILLUSTRATIONS NOT TO SCALE NOTE DIAGRAMS&ILLUSTRATIONS NOT TO SCALE 3 Insulate Joists Chimney Height LOCATION OF FIREPLACE Same As ceding Hearth Extension Dimensions The total height of your completed fireplace Carefully select the proper location for heat A 16" system from the surface the fireplace rests on circulation,aesthetics,chimney obstructions to the chimney top must not exceed 60' and and clearance to side wall(s).With proper pre- B 38" mustaiso meetminimum height requirements. planning,a slight adjustment of a few inches Draft Stops Refer to the minimum system height chart. can save considerable time and expense later C 8" during construction and assembly. -- Minimum System Height D 54" Security's FTF8 Pipe Note: To convert inches to millimeters fC e C J Firestop O A divide by 0 03937 I- D CTDT Vertical Installation 15'0" Al ; Figure 47 - -------------------------------------=11 �� Termination W:ll One Offset 15'0" VON_ Note:Nan- Two Offsets 25'0" Hearth 0 Methods of Determining Hearth Extension and Wall Shield Answer - The minimum required thickness of the Micore 160 is.875', Combustible -Tdetermine the thickness required for the alternate therefore roundup to 718"and use the nearest standard thickness available Equivalentso Chase `` Flashing material when either the"k"value or"r"value is known,use either the which is 1". Must Be Chase Enclosure Hearth Used To k formula or r formula. Cover n � Listed Material Chase A chase is a vertical box-like structure con- ° Example: If Micore 160 is to be used for the hearth extension fireplace, k(per inch) r(per inch) Listed Min Thickness Opening structedtosurround the fire lace andchimne . P Y how thick must this material be Listed Material o.a3 2.33 1" Refer to Figure 2 for a typical chase configura- Optional Outside Chase - Icy r� T� i1 tion. As with all chimney Installations, avoid - km=k value per Inch of alternate material r Figure 4 "Approved Alternate Materials for Floor/Hearth Protection gri Optional overhead obstructions such as trees, power g rM=r value per inch of alternate material lines,etc.A chase should be constructed and In Outside TM= minimum thickness required for alternate material AlternativeMaterials Thermal Values MinimumThickness Walls of insulated just like any outside wall. In a cold Carefully consider the position ofthe fireplace Ts = standard thickness of the alternate material (rounded to nearest 1/8 inch) Chase climate,we recommend the base of the chase opening with respect to the location of adja- k(per inch) r(per Min.Thickness 8• should also be Insulated between the solid cent or nearby stairwells,bath or kitchen ex- kL=k value per inch of listed material TM Levelcontinuous floor beneath the fireplace and the haustfans and/or return air registers forforced rL=r value per inch of listed material Kaowool M Board 47 2 13 1.09"(1-1r8 solid chase bottom.Chase insulation in a cold cli- air furnaces/air conditioners that could cause TL=minimum thickness of listed material Micore 160- .35 2.86 81-(7/8-) Continuous mate installation is not required for safet a smoking fireplace condition If the house is U.S.Gypsum Surface q Y� g p - tightly insulated. Note: An asterix"*"indicates,it is a value taken from Table 1. Micore 300"^ .46 2.17 107^(1-118') Outside ASSEMBLY OUTLINE Using the k formula: u.s Gypsum Insulation �-Base Before You Start When locating thefireplace,consideration must Durock'"Cement Board 1.92 .52 4 47^(4-1120 (Thermal Barrier) be given to combustibles and final finishing Minimum k-value(per Inch)of Specified min. u S.Gypsum Check your inventory list to be sure you have all See Figure 5 and confine the final location of thickness of = alternate material"x thickness Hardibacker,M 1.95 .513 4.53^(4-1/2') Figure combustible finish materials to the"Safe Zone". _ alternate k-value (per inch) of listed the necessary parts supplied in good usable Hardihacker 500TM' 2.30 435 5.35"(5-318' condition.Checkalsoforan concealed damage. material(TM) of listed material(kM) material(TL) Y 9 _ Colleted Stone Hearth- 2.82 .355 6.56"(6-112') • , 1 1 DO NOT permanently place furniture or other stone"" Check the operation ofthe damper.The damper items such as decorative pillows within 60"of TM(inches) = km x TL Wonderboard 3.23 .31 7.51"(7-1/21• 1 1• is controlled through the use of a control lever the fireplace front face. *.43 located within the firebox opening at the top Super Firetemp M .61 1.64 1.42"(1-318') ,•1• • , • • • 1 • centerjust behind the firebox lintel(Figure 3) Black Portion Of Frame TM(inches) _ *.35 x 1" Jahns-Manville Not To Be Covered With * Super Firetem The control lever snaps into place at the ex- .43 P P L .54 1.85 1.26"(1-1141 1 1 1 '' ' '-If' N 1181'All 1 14!A treme range of motion, up and back in the Combustible Materials Johns-Manvlle closed position. When pulled forward and .875 (inches) _ .875 x 1" Face brick 9.00 .111 20 93"(20.7/8' ,•1 ' : �• • • � damper� down,the dam is en. Wall - � Common brick 5.00 .20 11.63^(11-5/81P P 1Z'" Covering Answer -The minimum required thickness of the Micore 160 is.875", 45' O00o therefore round up to 7/8"and use the nearest standard thickness Cement mortar 5.00 .20 11.63"(11-5/81 WARNING: DO NOT PACK OR available which is 1 Ceramic the 125 .08 29.07"(29-1/81 QUIRED AIR SPACES WITH INSULATION Marble 11.0 .09 25.58"(25-518' OR OTHER MATERIAL. 1 MATERIAL IS Damper Damper Door Using the r formula: Table 1 Closed � � Open Opening ALLOWED AREAS. P 9 Minimum r-value(per Inch) Specified min. Lintel 12" Safe thickness of = Of listed material x thickness *'if the hearth extension material(s)that is intended to be used is NOT listed Note. Do not insulate the chase cavity with Zone on Table 1,the material can still be used if the material s)is noncombustible.alternate r-value (per inch) of listed material( s) or fill type insulation materials. material of alternate material material However,the manufacturer of the material must provide either the listed k- Combustion Figure 5 value per inch or rwalue per inch with listed thickness so that the minimum Note:Local codes ma notre uire fires in Air Actuator - thickness required for the hearth can be calculated(per instructions on this y 9 pp 9 TM(inches) - rL x TL page and/or as specified in the NF1 Certification manuals). at the ceiling levels for outside chase installa r M tions. However, it is recommended for safety Note:Also see NFl(NationalFireplaceinstitute)CertifrcationManualsshowing and the reduction of heat loss. Figure 3 TM(inches) _ *2.33 x 1" other acceptable calculation methods and acceptable alternate materials *2.86 which can be used. _ 4 NOTE DIAGRAMS&ILLUSTRATIONS NOT TO SCALE. 875 (inches) .875 x 1" NOTE DIAGRAMS&ILLUSTRATIONS NOT TO SCALE 17 � J If you're installing a gas line,connect it before It is_especlally important to Insulate between Finished wallboard ASSEMBLY STEPS 1. Estimate the total weight of the fireplace Top Header the fireplace is framed and enclosed in the the studs of an outside chase cavity and under system including chimney and surround ma- Spacers - finished wall.The gas knockout is determined the floor if the floor is above ground level.Do Max. Note:The following steps represent the normal terials such as brick, stone, etc., to be in- Maintain by the indentation located at-the bottom and not-place insulation directly against the fire- 1.1/2" sequence of installation. Each installation is stalled. Shipping weights for the fireplace 1"(25 mm) slightly off center in the side refractories.THE lace or chiriine-system may be found on page 18 --- Air Space 9 Y P Y y - unique,however,and might a different Y P 9 At Back KNOCKOUT IS ALWAYS REMOVED FROM IN- sequence. i And Sides SIDE THE FIREPLACE.DO NOT REMOVE THE FIREPLACE FINISHES 2. Measure the square footage of the floor KNOCKOUT UNLESS YOU ARE INSTALLING A Combustible 1. Position firebox prior to framing or into space to be occupied by the system,surrounds GAS LINE. If removal is attempted from the Mantels and Trim Mantel prepared framing. _ and hearth extensions. outer wrapper, side refractory damage may and Trim - occur With a medium-sized hammer, lightly 12"` Spacer 3.Note the construction,i.e. I Hearth tap the surface of the indentation.The refrac It is sometimes best to frame your fireplace Min. T 2. Install the chimney system. I--=— Extension after it is positioned and the chimney is in- T or 2 x 10's, single or double foists,type and 1"(25 mm)Space tory material is very thin in this area and is easily stilled.Frame enclosure for chimney and fire s"=- 3. Connect house wiring to the fireplace for thickness of floor boards. removed. Once a small hole has been made, place with 2 x 4's(or heavier)lumber. later attachment of optional blower. continue tapping until you have reached suffi- _ 4.Use this information and consult your local Metal Safety Strip/14" trip Floor cientdiameterforthe gas line to fit through.The Note:The headermayrestonthe two(2)metal 4. Install optional outside combustion air kit building code to determine if you need addi- Note: Hearth extensions must not interfere with entire knockout does not have to be removed Fireplace �, tional support. grillwork Remove insulation in the gas line channel. top spacers on top of the unit but the header Opening pp . circulating must not be notched to fit around the spacers - 5.Plumb gas line if a decorative gas appliance Figure 6 IMPORTANT:REPACK INSULATION MATERIAL 'Both Of These Dimensions Must Be At Least 18" will be used.(Gas connections should only be CAUTION:DO NOT BLOCK THE HEAT-CIRCU- When An Unvented Gas Log Set Rated At 32,000 LATING AIR INLET AND OUTLET PORTS ON IN SQUARE HOLE AROUND GAS LINE, INTE- These fireplaces may sit directly on a combus- BTU or Higher Is Used. (Maximum 40,000 BTU) performed by an experienced, licensed/cerci RIORANDEXTERIOROFFIREPLACE,TOSEAL.- tible surface. A 2"-airspace is required be- fied tradesman) CIRCULATING MODELS. DOING SO MAY RE- _ Top - • tween combustibleSULT IN A POTENTIAL FIRE HAZARD. Spacers framing and the chimney. Typical us Installation - Glass Doors A l"airspace is required between combustible 6.Complete the installation,finish wall mate- Maintain framing and fireplace outer wra er. Figure 46 rial, surround and hearth extension to our If you plan to raise the fireplace and hearth 1"(25 mm) _ 9 P PP Y �---- Air Space- , If glass doors are to be installed on these individual taste extension, build the platform assembly then I At Back fireplaces,refer to specific installation instruc- In Canada,the-minimum height for a com- Hearth-Extensions and Wall Shields position fireplace and hearth extension on top. And sides tions packed with the glass doors.Use only the bustible mantel is 18" (457 mm) above the 7. Assemble and attach optional glass door Secure the platform-to the floor to prevent doors that are listed for use with these fire- fireplace opening. Figure 45 shows typical A hearth extension must be installed with assembly. possible shifting places. Use of other non-listed glass door on , Canadian installations.For installations other all fireplaces. It is to protect the combustible l f he irepacefrom both radiant these fireplaces may constitute a potential fire than Canada, combustible mantels and trim floor in front of t - Study the three dimensional illustration(Fig- CLEARANCES _ I Hearth - heat and sparks. The hearth extension must L-- — hazard and is not recommended. maybe installed 12"above the fireplace open- ure 1)to get a general idea of each element of Extension ing as per NFPA 211, Section 7-2.3.3. and extend 8"beyond both sides of the fireplace your fireplace system. Minimum clearance to combustibles for the 1"(25 mm)space CAUTION: opening and"6"beyond the front(see Figure _ION:CERTAIN GLASS DOORS OVERLAP Figure 96. If a mantel is of a noncombustible - - appliance is as follows-sides and back-1"(25 - 47).Use a hearth extension constructed of a THE BLACK METAL FACING OF THE FIRE- material, it is exempt from these require- PRE-INSTALLATION NOTES mm),floor 0"(Omm),adjacentwall-12"(305 PLACE.IF THE FIREPLACE HAS BEEN FACED durable noncombustible material having an mm ceiling--37-1/2" 953 mm ments as long as it does not interfere with the ). ( )• 'equal or better(lower kvalue)Insulating valueMetal safe stri Platform Floor ' WITH NONCOMBUSTIBLE MATERIALS,THERE installation or operation of glass doors. z e The fireplace may be installed directly on a ty P - MIGHT NOT BE SUFFICIENT CLEARANCE TO of k ='.43 BTU IN/FT,HR F or a thermal INSTALLING THE FIREPLACE resistance that equals or exceeds r=2.33 HR combustible floor or raised on a platform of an Note: Hearth extensions must not interfere with INSTALL THE GLASS DOORS OF YOUR' o z appropriate hei ht. Do not lace fireplace on -circulating grillwork Finished F FT/BTU IN With these values,determine9 P P CHOICE.ENSURE ADEQUATE CLEARANCE IS Wallboard Header car etin ,vin I or softfloor coverings.s.It Step 1.Slide the fireplace into prepared fram- - MAINTAINED AT ALL TIMES SO AS NOT TO the minimum thickness/material required us P g Y g in or osition fire lace in its final osition and Figure 7. INTERFERE WITH THE INSTALLATION AND ing the formula and Page 17. may, however, be placed on flat wood, ply 9 P P P B Max. wood, particle board or other hard surfaces. frame later. OPERATION OF GLASS DOORS. " Note.Install the hearth extension onlyas illus- (203mm) Note:Any noncombustible material whose k Be sure fireplace rests on a solid continuous trated. COLD CLIMATE INSULATION - value is less than.43 or whose r value is more floor or platform with appropriate framing for The fireplace may not be recessed into a com- than 2.33 is acceptable. r° support and so that no cold air can enter the bustiblefloor.Maintain the floor to hearth clear- room from under the fireplace. ance established by the fireplace lower front The safety strips should extend from front of If you live in a cold climate, it is especially face. the fireplace at least 1-1/2"and should extend to important to seal all cracks around thefireplace an If the fireplace isinstalled on-a combustible r be at least flush with the sides. In the event a floor,use the metal safety strips(provided) The fireplace may be positioned and then the opening with noncombustible-material and - wooden support is-used to elevate the fireplace 16"Min. Spacer on the floor extending half under the fire- framing built around it,or the framing may be Step 2.Insert the provided metal safety strips, wherever cold air could enter the room. Sur- - abovethefloor,a"Z"type safetystripshouldbe (457mm) lace and half under the hearth extension constructed and the fireplace positioned into beneath the fireplace as illustrated(Figures 6, rounding materials must be caulked where it P - 1 P land 8 .The safety strips should overlap 1/2" fabricated and used to protectthe front surface (refer to Figures 6&7) the opening. ) Y P P meets theblack�metalfaangofthefireplaceto -• _ � of the wood support as well as the floor beneath for continual coverage of the floor avoid cold air intrusion Use noncombustible the hearth extension (Figures 8 and•9).The caulking material only on fireplace facing to - A wall shield is required where a continuous Usually,no special floor support is needed for safety strips should be tacked down to prevent seal.Also,the outside air inlet duct should be perpendicular side wall is within-12" of the the fireplace,however,to be certain: Note.Safety strips are not required when fire- P _ possible movement. ed with noncombustible insulation to Fireplace fireplace opening(Figure 48).Use a 36"W x place rests on a noncombustible surface. wrapped the formation of condensation -Do Opening 36" H wall shield constructed of durable, Note.The"Z"type safety strip is not supplied. noncombustible material having an equal or _ � - � - _ _ not place insulation materials on top of fire Typical Canadian Installation better(lower kvalue)insulating value than k= place or against chimney sections. .54 BTU IN/FTT2 HR OF. At no time may a Figure 45 perpendicular side wall be located closer Note:A 2"air space must be,preserved for all combustible materials extending for any con— tinuous length adjacent to the chimney. If fireplace is Installed diagonally across a 90° corner;no wall shields are required. 16 NOTE DIAGRAMS&ILLUSTRATIONS NOT TO SCALE _ . - NOTE DIAGRAMS&ILLUSTRATIONS NOT TO SCALE 5 FIREPLACE SPECIFICATIONS m Op[ona EFIRPLACE After completing the installation of the optional Note:Using a soapy water solution(50%dish ower Kit Operates on 115 volt 60 Hzcombustion air vent system the actuator arm soap, 50% water) is an effective leak test 150 watts AC 121/2" _ must be put In service and tested to ensure solution but it is not recommended,because �(31a mm) ►{- proper operation before completing any enclo- the soap residue,that is left on [he pipes/ a-3/a^ sure around the firebox. Failure to do so may fittingscan result incorrosion overtime.Never (213 mm) HOUSE result In extensive and costly rework use an open flame to check for leaks. 16-5/16" (414 mm) Locate the actuator arm along the right side of This provision is Intended for connection to a the appliance firebox opening and refer to decorative gas appliance Incorporating an au- Figure 44 tomatic shut-off device and complying with the Standard for Decorative Gas Appliances for Metal Safety Strips O GROUND installation in vented fireplaces,ANSI Z21.60 41" 1788" WIRE (1041 mm) (1178 mm) COVER PLATE (1991)or American Gas Association draft re- House Wiring Must Be Secured Replace Cover Plate �(' 40-1/2^ WithTheAppropnateElectrical Aber Electrical o l quirementsforGas Fired Log LlghtersforWood 22-5/16" 2-7/8" Connector ToTheFireplace Hook-Up _ Burning Fireplaces, Draft No 4 dated August, Figure g _ (1029 mm) (566 mm) _ - Convenience Outlet Wiring - (73inm) 1993. Install in accordance with the National Figure 42 Fuel Gas Code,.ANSI Z2231. This complies Combustion with the revised U L.127 standard. THIS FIREPLACE IS NOT INTENDED TO BE Air Actuator Blocking USED AS A SUBSTITUTE FOR A FURNACE TO Vent Free Appliances II� _I HEAT AN ENTIRE HOME. USE FOR SUPPLE- 46-3/4" UPPLE- This unit has been tested and approved to MENTARY HEATING ONLY.(1187 mm) ANSI/IAS/AGA Z21.11 2 for use with unvented Front gas appliances and complies with the Stan- - Fireplace Top Spacers J �� u _ dard for FactoryBuiltfireplaces,UL 127,when } 1/2" f.— installed with unvented gas log sets Special / 03 mm) ��� Instructions with regards to mantle installa- Metal Safety Strips PF::1 F _ Q Pull Forward to Open, tions must be taken into consideration when Figure 9 Push Back to Close installing such,appliances. Figure 44 Combustion 9-7/8" The unit has been tested for use with any Step 3. Refer to fireplace drawings and specifi- Air Inlet (251 mm) unvented log sets having a maximum rating of To operate,push the end of the actuator to the cations on pages 6 and 7 forframing dimensions � 32,000 BTU. The minimum mantle configura- Gas Line , left as shown in Figure 44,until it"pops"free of and details Frame appliance enclosure as illus- Access tion for these log sets are outlined in Figure 46. trated In Figures 11 through 14 on page 8 4s-3/e^ its"locked"position. Pull the actuator forward _ 9 9 P 9 (1178 mm) \> too en the combustion air door,and push it 41-3/8" -- ----- 10^ / BLOWERTHREE P p Log sets with 40,000 BTU may be Installed - --------- (105 num) (254 mm) PRONGED PLUG TO back to close.To"lock"the combustion air door IMPORTANT: UNDER NO CIRCUMSTANCES / GROUNDED OUTLET provided that no combustible mantle projec- CAN THE FIREPLACE TOP SPACERS(FIGURE 40-1/2^ closed, ensure the actuator Is pushed all the tions are placed lower than 18 inches from the Gas Line (1029 mm) 17-5/16" way back then push the end of the actuators to fireplace opening. 10)BE REMOVED MODIFIED,NOR MAY Access (439 mm) (3465mm) Figure 43 the right until the step in the actuator moves p YOU NOTCHTHE HEADERTO FITAROUND OR " BE INSTALLED LOWER THAN THE SPACERS. Junction behind the appliance front face within the slot- These fireplaces have been marked with a THE HEADER MAY BE IN DIRECT CONTACT The FBK-100/200 Blower Kits are design certl- ted opening. maximum rating of 32,000 BTU to assure that WITH THE TOP SPACERS BUT MAY NOT BE fied by Warnock Hersey for use with these homeowners do not exceed the allowable lim- SUPPORTED BY THEM. 23-1/2" 22-7/8" appliances.- Operate the actuator through several cycles its for all allowed installations of mantles.That (597 mm) (581 mm) '� including the"lock position. Ensuring proper limit may be increased to 40,000 BTU, pro- Always check local building codes Installation operation and freedom of movement. Return vided that the mantle Installed complies with Note: The framed depth, 23=7/8" (606 mm) - Left Side Right Side P from a framed wall,must always be measured of the FBK Blower Kits must comply with local the actuator arm to the locked position. the 18-inch limitation and a copy of these from a finished surface.If wall covering such 31-9/16^ regulations as well as the National Electric Instructions are available. as drywall is to be attached to the rear wall,then (802 mm) Code. Gas Line Connection the 23-7/8"(606 mm)must be measured from O 0 O O Fireplace NEVER INSTALL AN UNVENTED GAS LOG 86 m Top Spacer Combustion Air Kits Install a,1/2"gas supply line through fireplace SET WITH A BTU GREATER THAN 32,000 IF the drywall surface. It is important that this (z1s mm) dimension be exact. _ wall for connection to a decorative gas apple- COMBUSTIBLE MANTLE PROJECTIONS ARE 23-1/2" These a liances�are a ui ed with an outside ance inside the firebox.Outside,the assu I LOWER THAN 18 INCHES ABOVE THE FIRE- If the appliance is to be elevated above floor I (make-up)air door and integral actuator arm. If line connects to a gas shut-off valve recessed PLACE OPENING. 12-1/2"` theappliance istobeinstalledwithan,outsideair flush into the wall or floor.The valve should be level, a 'solid continuous platform must be � � � � �, 318 mm) constructed o 0 0 0 0 vent system,use only FireCraft Models FAOK-4 controlled by a removable valve key for safety. CAUTION: WHEN USING THE DECORATIVE or.FAOK-4LD Combustion Air Kits. These kits GAS APPLIANCE, THE FIREPLACE DAMPER The header may rest on the top metal spacers, 1-3i4" _ 46-3/4 come complete with detailed installation instruc- Always plumb gas line installation per local MUST BE SET IN THE FULLY OPEN POSITION. but must not be notched to fit around them (44 mm) 7 �— (11 67 mm) � tions and all components necessary in complet- codes.Check all connections and test for gas 50-1/4" Ing y ''a combustion air vents stem - leaks, using gas as leak test solution also CAUTION:PLUMBING CONNECTIONS SHOULD Consult all local codes. (1276 mm) referred to as bubble leak solution). ( ONLY BE PERFORMED BY A QUALIFIED, LI- ' Top View CENSED PLUMBER.MAIN GAS SUPPLY MUST BE OFF WHEN PLUMBING GAS LINE TO FIRE- Figure,10 PLACE OR PERFORMING SERVICE. 6 NOTE,DIAGRAMS&ILLUSTRATIONS NOT TO SCALE - - NOTE DIAGRAMS&ILLUSTRATIONS NOT TO SCALE 15 ;V.. 1 I INSTALLING OFFSETS Step 5. Secure support straps to framing FRAMING SPECIFICATIONS 1 members by nailing under tension in sheer _ First, review the Offset Elevation Chart and (Figure 41) Joints Figure 38 for reference Framing Dimensions f, ) T A 49" 1245 mm Back Wall of C FOAK Combustion Chimney a�; Step 1. Determine the offset distance where Chase/Enclosure Air Kit-Optional y ��� -. Section �QQ�" chimney is to pass through the first ceiling- B 46-1/2" 1181 mm Includmq Flnismg a' dimension"A."To find this point on your cell- r if MateriaFs Ing,first determine the center point for a verti- C 33" 838 mm o cal chimney following the Instructions for ver- D 17-1/2" 445 mmO F �a\o No.8 x 1/Zn SMS tical Installation. s'moo?` Return Header E 81" 2057 mm Measure height to the ceiling from the top of Elbow F 40-3/8" 1026 mm arc fireplace-dimension "B." Use the appropriate X A � Offset Elevation Chart to find dimension"A." Figure 41 G 24" 607 mm Rough la– E ►I Mark point where you will drive your nail to (Un Framing Face H 23" 584 mm nished Shown) r' fi Figure 38 show the center point for your offset ceiling cut. Note:The return elbowassemblyperforms the B Comer Installation same function as a stabilizer. Consider this J 57-1/4" 1454 mm Step 2.Proceed by using the Straight Up Instal- when determining the need for a stabilizer Figure 14 lation Instructions for cutting and framing ceil- lcu- Ing and roof openings. Note:Do not apply excessive pressure to an Note: All framing dimensions caand PPY P Y �—A � lated for 5/8'Watling flange depth and subsequent chimney section following return Fireplace Framing 1/2"dry wall at the fireplace face. If ' Note:See Framing and Dimension Chart for the elbow assembly when installing. Ensure that sheathing the chase or finishing with sizes of the ceiling and roof openings.The size each subsequent chimneysection is securely other thickness materials,calculations of the roof opening varies with the degree of q Y Figure 11 will need to be made. P 9 9 attached by testing as noted above , pitch of the roof. Note: A,C and G dimensions include OPTIONAL EQUIPMENT - Underside Of Chimney Offset Elbow Assembly CONSIDERATIONS Backwall of Chase/Enclosure FORK Combustion 1"clearance to combustibles Including Finising Materials if any Air Kit Offset elbows install the same as chimney Blower Kits(Circulating Models Only) Figure 39 sections First,snap the inner section INTO the Framing Dimensions for Ceiling preceding Inner section of flue Check connec- Blower Kits model FBK-100/200 are available WBtion by pulling up slightly to ensure a tight fit for use with circulatin models. The Blower O G Flue Type A B FTFS-E30 Return Elbow' Next,the outer sections snap lock OVER the g preceding outer section of chimney Again, Kit can be installed prior to or after installation Ceiling Framing p g y g of the fireplace � FTF8 Vertical 16-1/2" 16-1/2" 9 9 Chimney Section(S) check outer section by pulling up slightly to (419 mm) (419 mm) ---- ensure proper connection is made. I� A �1 Rough Fi ure 15 Note: These fireplace models require a wall Framing Face g switch for fan operation. Refer to the installa- Inside chase (Unfinished Shown) FTF8 Offset 30° 16-1/2" 27" Return Elbow Assembly tion instructions included with the Blower Kits (419 mm) (686 mm) FTF8-30 Offset Elbow' B Return elbows install the same way as round for installation details. Figure 12 terminations and stabilizers: THE FIREPLACE MUST BE WIRED TO THE A - Step 1. Hold return elbow over top of last HOUSE ELECTRICAL SYSTEM AT THE TIME OF INSTALLATION IN ORDER FOR THE OP- -- -- Chimney section. - Back wan of Chase/Enclosure FORK ' TIONAL FANS TO OPERATE, (SEE FIGURES Including Fimsing Materials Combustion \ 42 AND 43). if any AirKit-optional, Framing Dimensions for Roof Step 2.Center inner slip section Into inner flue pipe-slip down. Note: The utilization of fans will increase the Pitch C D* Step 3.Center outer-locking section over outer air flow around the firebox However, only a chimneypipe.Pushdown until lockingJointhas minimal increase in heat output should be H7!IG 0/12 16-1/2" 16-1/2" firmly engaged. anticipated. _ (419 mm) (419 mm) 'Part of Offset/Return Package Model FTFB-ES30 A• �, Step 4. Pull up slightly on return elbow to Rough 6/12 9 m 19 c Figure 40 ensure lockingjoint has firmly engaged. (Unfinished ownStFacj outside Chase ( ) (483 mm) o 12/12 1 16-1/2" 23-1/2" Roof Framing Figure 13 (419 mm) (597 mm) Perpendicular to roof eFigure 16dge - 14 NOTE DIAGRAMS&ILLUSTRATIONS NOT TO SCALE NOTE DIAGRAMS&ILLUSTRATIONS NOT TO SCALE 7 r Step 4. Fireplace should be secured to side Step 7.Route the Class 0 metallic air duct out A, OFFSET ELEVATION CHART framing members using the nailing tabs at the the backwall or side wall,up through the ceiling top and bottom of the fireplace front face. Use or floor joists to an outside wall.The air duct's 8d nails or equivalent(Figure 17) inlet should be located above any anticipated Return A B F7F8-ES30 Number of FTF8 Chimney Sections snow level. Elbow Offset Height Offset/Return FTF8-S4 20' (Inches) (Inches) Elbow Stabilizer 12" 18" 36" 48" Note: If the fireplace is installed against an Max 4 15 3/4 1 0 0 0 0 0 inside wall,the Class 0 metallic air duct maybe a ® ® 9 24 1/2 1 0 1 0 0 0 extendedintoa ventilatedattic space at least 18" ' Stabilizer 12 29 3/4 1 0 0 1 0 0 (457 mm)above the attic floor.Secure the duct 14 1/4 33 '/2 1 0 2 0 0 0 hood to a vertical post with the inlet positioned 17 1/4 38 1/2 1 0 1 1 0 0 8d Nail Or downward Ensure thatnothingblocks the hood 10'Max. 20 1/4 43 3/4 1 0 0 2 0 0 o Equivalent opening. This air duct must never terminate 21 45 1/4 1 0 0 0 1 0 0 higher than the fireplace chimney. zz 1/4 47 '/2 1 0 2 1 0 0 Onset Step 8.Cut or frame a hole through the outside ^ Elbow 25 '/4 52 '/z 1 0 1 2 0 0 26 /4 54 /4 1 0 1 0 1 0 o wall for the installation of the duct inlet hood.A 6-1/2" (165 mm) diameter hole is required Figure 19 27 55 3/4 1 0 0 0 0 1 Feed the loose end of the flexible duct through 28 1/4 57 3/4 1 0 0 3 0 0 the hole cut for the inlet hood and attach to the Step 3.Position appropriate firestop spacer at 29 1/4 59 1/4 1 0 0 1 1 0 collar on inlet hood using two(2)screws.Insert ceiling and fasten temporarily with two(2)8d 31 1/4 63 1 0 2 0 1 0 Figure 17 the hood into the opening in place lace with nails or equivalent Use flat firestop spacer, Figure 36 32 1/4 64 1/2 1 0 1 0 0 1 Note: The nailing tabs and the area directly nails driven through the holes In hood flange. Model F8FS-2, if chimney penetrates ceiling 34 '/a 68 1/4 1 0 1 1 1 0 Seal with noncombustible waterproof silicon vertically If chimney penetrates ceiling at 30° 35 1/4 69 3/4 1 0 0 1 0 1 behind the nailing tabs are exempt from the type caulking. If additional air duct is needed, angle(offset chimney),use 301 firestop spacer, 37 1/4 73 1/4 1 0 0 2 1 0 clearances described on page 5. Maintain at use Class 0 metallic duct. Model F8FS30-2 Use one nail on opposite ' 38 1/4 75 1 0 0 0 2 0 least 1"clearance from the firebox wrapper to sides to hold firestop spacer in position.Fasten A2 39 1/4 77 1 0 2 1 1 0 the framing at the closest point of contact INSTALLING THE CHIMNEY SYSTEM permanently, using at least two (2) more 8d 41 1/2 80 1/2 1 0 1 4 0 0 directly adjacent to the flange. nails or equivalent,after chimney sections have c2 � 43 1/4 83 3/4 1 0 1 0 2 0 Step 1.Before continuing,check the operation been assembled through the firestop spacer B2 44 1/4 85 1/4 1 0 0 0 1 1 For Canadian Installations Proceed ofthe damper,as described on page 4,(referto and after any necessary adjustments have been 45 1/4 87 1/2 1 0 0 3 1 0 with Steps 5 through 8 Figure 3) made. Firestop spacer must be secured by at A' 46 1/4 89 1 0 0 1 2 0 least four(4)8d nails or equivalent when com- ® ® 48 1/4 91 1/2 1 0 2 0 2 0 Step 5. Attach the cold climate kit, Model Step 2. Using standard construction framing pletely installed. 49 1/4 94 1/4 1 0 1 0 1 1 CCK-HCRD, around the chimney collar with techniques,construct opening for chimney route �\ B, 50 1/4 95 3/4 1 0 0 0 0 2 the screws provided (see Figure 18). up through the celling(s)and roof orthrough an Note: If there is a room above ceiling level, c, 51 1/4 97 3/4 1 0 1 1 2 0 outside chase. firestop spacer must be installedon thebottom 54 1/4 103 1 0 0 2 2 0 Note:CCK-HCRD model requires a 6"diameter side of the ceilingIf an attic is above ceding 55 /4 104 + Class 0 metallic air duct .acquired locally by Framing must maintain adequate minimum air /2 1 0 1 0 0 2 installer, space clearance at all times level,firestop spacer must be installed on top 56 1/2 106 1/2 1 0 2 1 2 0 side of ceiling joist(Figures 20 and 21) 58 1/4 109 3/4 1 0 0 1 0 2 Chimney Duct CAUTION: ALLOW MINIMUM 2" CHIMNEY 61 3/4 116 1 1 1 0 3 0 AIR SPACETO COMBUSTIBLE FRAMING MEM- Room Above 64 3/4 121 1/4 1 1 0 1 3 0 Duct Collar 67 124 3/4 1 1 2 0 3 0 Front Cover BERS THROUGHOUT VERTICAL OR OFFSET Plate"A" CHIMNEY INSTALLATION. �, 68 3/4 128 1 1 0 0 1 2 A2 70 130 1 1 1 1 3 0 A minimum 2"air space must be reserved for 73 135 1/4 1 1 0 2 3 0 all combustible materials extending for any o _ c2 74 3/4 138 1/4 1 1 0 0 0 3 continuous length surrounding the chimney. 1 � Bz 79145 1/2 1 1 1 0 4 0 Firestop Spacer 80 147 1/4 1 1 1 0 0 3 Reference Figures 15and 16 and charts Fram- A+ 82 150 3/4 1 1 0 1 4 0 Front Cover ing Dimensions for Ceiling and Roof, which Figure 20 ® ® 82 1/4 152 1 1 1 0 1 1 1 0 1 3 Plate"B" specify minimum ceiling and roof dimensions T Attic Above T ` Front Cover Plate"A" Knockout In new construction,to determine chimney cen- B, ter line,use plumb line from roof or ceiling above c'�` Figure 18 fireplace to center of flue collar on fireplace. T Step 6. Connect the 6" (152 mm) Class 0 For remodeling,plumb to center of flue collar metallic air duct to the collar on the chimney from ceiling above, drive nail through ceiling collar enclosure with the screws provided in from below to mark position,then mark and cut the hardware kit toassa a from above ceiling around nail P 9 9 ( ) Firestop Spacer (see Figure 19).Then plumb from ceiling or roof level directly above hole which has just Figure 21 been completed. Figure 37 8 NOTE DIAGRAMS&ILLUSTRATIONS NOT TO SCALE NOTE DIAGRAMS&ILLUSTRATIONS NOT TO SCALE 13 i The offset and return elbows may be attached FTF8 VERTICAL ELEVATION CHART CHIMNEY 30°OFFSET THROUGH FLOOR Step 4. Note: Chimney sections are con- Note:Assemble one component of chimney at together,or a section or sections of chimney OR CEILING structed with a unique locking tab design, a time(inner section first, then outer section maybe used between,but do not exceed 20'in Height Of Number Of FTF8 Height Of Number Of FTF8 which ensures an immediate,tight assembly last)before proceeding with the next complete total length between elbows.If sections of pipe Chimney Only Chimney Lengths Chimney Only Chimney Lengths It may be necessaryto assemble the chimney at between sections.Plan your chimney require- section. exceed 10'between elbows,a chimney stabs- Inches Feet/inches 12" 18" 36" 48" Inches Feet/inches 12" 18" 36" 48" 30°when passing through the floor or ceiling ments carefully before assembly as chimney lizer must be used at the midpoint(Figure 36) 11 0 11 1 0 0 0 386 1/2 32 2 1/2 0 1 0 a area Use the F8FS30-2 firestop spacer as is difficult to disassemble after installation.If Continue to assemble the chimney up through The stabilizer support straps must be attached 17 1 5 0 1 0 0 390 3/4 32 6 3/4 2 0 0 s shown in Figures 22 and 23 Support the disassembled, the tabs might become dam- framed opening.Assemble justenough to pen- under tension(in shear)to structural framing 21 1/4 1 91/4_ 2 0 0 0 396 3/4 33 0 3/4 1 1 0_ 8 chimney at floor or ceiling penetration with a aged Be certain tabs are properly formed to etrate the roof flashing openings(Figure 27). 27 1/4 2 3 1/4 1 1 O_ 0 404 1h 33 8 1/2 0 0 1 8 FTF8 stabilizer if distance of chimney below ensure locking tabs engage properly. Always maintain 2"minimum air spaceto com- membersabove.When two sets of elbows are 35 2 11 0 0 1 0 414 3/4 34 6 3/4 1 0 1 s y used,the maximum combined length of chim- 47 3 11 0 0 0 1 416 1/2 34 81/2 o 0 o s ceiling is 10'or more.Maintain 2"minimum air bustible materials and always checkeachchim ney-used between elbows cannot exceed 20' 51 1/4 4 3 1/4 0 1 1 0 420 3/4 35 0 3/4 0 1 18 space to combustibles from chimney sections. The Security FTF8 chimney system is a two ney joint (inner and outer) to ensure proper 57 1/4 a s 1/4 1 0 0 1 426 3/4 35 6 3/4 1 0 0 9 piece chimney,which snap together from the engagement Check vertical alignment of chim- (Figure37).Example:IfCt=1UthenC2cannot 631/4 5 31/4 0 1 0 1 4323/4 36 03/4 0 1 0 s exceed 10'. 67 1/4 s 7 1/4 2 0 0 1 437 36 5 2 0 0 9 Attic Space fireplace up. Start with the inner flue section ney so that it projects from the roof in true 73 1/4 6 1 1/4 1 1 0 1 443 36 11 1 1 0 9 with the lanced end up,snap lock it in to the vertical position. 81 1/4 6 9 1/4 0 0 1 1' 450 3/4 37 6 3/4 0 0 1 s FBFS30-2gpa_ce, matching collar on top of the fireplace.At all If an offset exceeds 6'in length,each chimney 93 1/4 7 9 1/4 0 0 0 2 461 38 s 1 0 1 9 FirestopSpacer2"Min. joint beyond the first 6'of offset to the return 97 1/4 8 1 1/4 0 1 1 1 462 3/4 38 6 3/4 0 0 0 10 Air Space subsequent joints, the upper flue section fits elbow,must be secured by a No.8 x 1/2"sheet 102 v2 a 6 1/2 1 0 0 2 466 3/4 38 10 3/4 0 1 1 9 '` into the preceding flue, section. Each piece 109 'A 9 1 1/4 0 1 0 2 472 3/4 39 43/4 1 0 0 10snaps together by means of locking tabs-(9 metal screw located at the underside ofthejoint 113 1/2 9 s 1/2 2 0 0 z 478 3/4 39 10 3/4 0 1 0 10 \ \�� (Figure 38). 119 1/2 9 11 112 1 1 o z 483 40 3 2 0 0 10 locking tabs per joint). Check each piece by -- 1271A 10 71/4 0 0 1 2 489 40 9 1 1 0 10 2"Min. tabilizer pulling upslightlyfromthetoptoensureproper 137 1/2 11 5 1h 1 0 1 2 496 3/4 41 4 3/4 0 0 1 10 Air Spaceen a ement before installin the next sectionA 1/8" diameter hole must be drilled in the g g g 13s 1/4 11 7 1/4 0 0 0 3 508 az 3 1 0 1 10 If the fluehasbeeninstaIledcorrectl itwdlnot chimneyjoint using a 1/8"diameter drill Hole 143 Y2 11 11 1/2 0 1 1 2 sos 3/4 42 4 3/4 0 0 0 11 Y' should be drilled in center of joint overlap 149 1/2 12 s 1/2 1 0 0 3 513 42 9 0 1 1 10 Max 30°Firestop separate when you test it.Also,the inner flue 1"•Min.Air Space 155 1/z 1 12 11 1h 0 1 0 3 519 43 3 1 0 1 0 11 And Attic Above joint where each section is joined should be To Combustibles (Figure 39). Be sure to drill only through the 159 3/4 13 3 3/4 2 0 0 3 525 43 9 0 1 0 11- outer chimney casting Do not puncture the. 1651/4 13 9 3/4 1 1 0 3 529 1/4 44 1 1/4 2 0 0 11 Figure 22 tight and flat without gaps(Figure 25). inner flue. 173 1/z 14 5 1h 0 0 1 3 535 1/4 44 71/4 1 1 0 11 Figure 27 183 3/4 15 3 3/4 1 0 1 3 543 45 3 0 10 1 11 Room Above 185 1/2 15 5 1/2 0. 0 0 4 553 1/4 46 1 1/4 1 0- 1 11 Security's chimney sections do not need to be Maximum offsetof chimneysystern is 300.Two 189 3/4 15 9 3/4 0 1 1 3 555 46 3. 0 0 0 12 FBFS30-2 screwed together Additional reinforcement is offsets must not be assembled to forma 600 195 3/4 16 3 3/4 1 0 0 4 5F11/4 1/4 46 1 1/4 0 1 1 11 Firestop Spacer 2"Min 201 3/a 16 9 3/4 0 1 0 4 47 1 1/4 1 0 0 12 Air Space � not necessary except in certain offset-condi- offset.However,,two sets of offset and return 206 17 2 z o 0 4 47 5 1/4 0 1 0 12 tions.(refer to page 14,Figure 38) elbows may be used on a single flue system, 212 17 8 1 1 0 4 47 11 1/2 2 0 0 12 __ provided the total height of the system exceeds 219 3/4 18 3 3/4 0 0 1 a 48 s 1/2 1 1 0 12 --- 230 19 2 1 0 1 4 49 1 1/4 0 0 1 12 Step 5. The height of vertical chimney pipe 25'. 231 3/4 19 3 3/4 0 0 0 s a9 11 1/z 1 0 1 12 2"Min. / FTFa-S4 Stabilizer --- supported only by the fireplace must not ex- 231 19 a o 1 1 a 50 1 1/4 0 0 0 13 Air Space ceed 30' Chimney heights above 30'must be Return elbow support straps must be securely 242 20 2 1 0 0 5 50 5 1/z o 1 1 12 attached under tension(in shear)to structural 248 20 a o. 1 0 s 611 1/2 51 11 1/2 1- 0 0 13 supported by a Model FTF8-S4 stabilizer in- z52 21 0 2 0 0 s 617 1/2 51 s 1/2 0 1 0 13 1W 30°Firestop , stalled at 30'intervals framing members above. Do not substitute a 258 21 6 1- 1 0 5 621 1/2 51 9 1/2 2 0 0 13 Max. And Room Above FTF8-30 offset elbow in place of a FTF8-E30 266 22, -2 0 0 1 5 627 1/2 52 3 1/2 1 1 0 13 return elbow. 276 23 0 1 0 1 s 635 �h 52 11 1h o 0 1 13 Figure 23 Note:The Model FTF8-S4 adds 3"net effective 278 23 2 0 0 0 6 645 1/2 53 s h 1 0 1 13 Figure 25 height to the total chimney system. 282 23 6 0 1 1 5 647 1/2 53 11 1/z 0 0 0 14 OFFSET CALCULATIONS 288 24 0 1 0 0 6 651 1/2 54 3 1/2 0 1 1 13 For Canada Only Outer pipe section installs injust the opposite 294 3/4 24 6 3r4 0 1 0 6 657 1h 54 9 1/2 1 0 0 14 P p j pp Install the Model FTF8-S4 stabilizer by fitting 298 1/4 24 10 1/4 2 0 0 6 663 1h 55 3 1/2 0, 1 0 14 When installing the chimney system through an way;the lanced end goes down and each new inner section down into respective section of Step 1.Use Offset Chart to,determine amount 304 1/4 25 41/4 1 1 0 6 667 3/4 55 7 3/4 2 0 0 14 section goes OVER the outside of the previous 31z zs o 0 0 1 s s73 3i4 ss 1 3r4 1 1 0 14 � open attic space, the attic shield assembly- g p proceeding flue pipe and locking outer stabi- of horizontal offset(A)and height(B)for vari �, section installed(Figure 26). 322 1/4 26 10 1/4 1 0 1 6 681' 112 56 9% 0 0 1 14 firestop spacer must be used(Figure 24).This sizer section into place over the outer chimney ous chimney section assemblies. 324 27 0 0 0 0 7 691 3/4 57 7 3/4 1 0 1 14 installation is required only for use in Canada. pipe Position for proper clearance through 328 1/4 27 4 1/4 0 1 1 6 693 1/2 57 9 1/2 0 _ 0 0 15 framed opening and nail straps securely(under Step 2.Use"Height of Chimney Only"column 334 1/4 27 10 1/4 1 0 0 7 697 3/4 58 1 3/4 0 1 1 14 t 340 1/4 28 4 1/4 0 1 0 7 703 3/4 sa 7 3/4 1 0 0 -15 Open attic space tension in"shear")into place on framing.Use in The Vertical Elevation Chart to determine 344 1/2 28 8 1/2 2 0 0 7 709 3/4 59 1 3r4 0 1 0 15 8d nails.Attach successive lengths of chimney combinations of chimney,used above return 350 1/2 29 2 1/2 1 1 0 7 714 59 6 2 0 0 15 `—————— elbow to achieve desired heights. Reference 3581/4 29 10 1/4 0 0 1 7 720 60 0 1 1 0 1s pipe directly to stabilizer using same tech Components Effective Height Chart in vertical ass 1/2 30 s 1/2 1 0 1 7 71/3/4 60 7 3i4 0 0 1 15 Locking niques as described in Step 4(Figure 28). p g 370 1/4 30 10 1/4 0 0 0 8 738 61 6 1 0 1 15 Tabs elevation Chart SBCiIOn. 374 YZ 31 2 1h 0 1 1 7 739 3/4 61 7 3r4 0 0 0 16 (Lances) 3801/z 31 81/2 1 0 0 a 744 62 0 0 1 1 15 i T 1 Step 3. Use Elevation Chart as job estimator only.Add necessary firestop spacers and sta- bilizers as required Firestop spacers must be used as shown in Figures 22 and 23 and stabilizers as shown in Figure 28. � Figure 24 Figure 26 Note: For Canadian installations, all chimney installedoutside thebuildingmustbe constructed FTF8-S4 Stabilizer with galvalume (outer sections only) effective Figure 28 January 1, 1992. The appropriate model desig- nations are located in the back of this manual. ' NOTE DIAGRAMS&ILLUSTRATIONS NOT TO SCALE _ 9 12 f ' i Note:Do not apply excessive pressure to any Step 8. Slide the FTF8 storm collar (ordered Step10.UsingaFTFB-CTD Round Termination: Less Than io To determine the number of chimney sections subsequent,chimney sections following the separately)over outer chimney,rest on flash- and chimney components required, follow _ stabilizer when installing.Ensure each subse- ing spacers and align with top surface of flash- 1.Hold the FTF8-CTD over top of last chimney these steps• quentchimneysection is securely attached by ing. Insert tab in slot, pull tight and bend tab section(Figure 33): 2'Min. testing as noted in Step 4. back over slot.Seal storm collar to outer chim- 1.Determine total vertical height of the fireplace ney with roof caulking or mastic around entire 2.Center inner slip section in inner flue pipe- N3' installation This dimension is the distance from Step 6.Select the proper Security roof flash- circumference of pipe. Also add extra roof slip down. 10' 3' the surface the fireplace sets on to the point ing based on pitch of roof.Use chart below for caulking to the tab/slot area to seal completely Min where smoke exits from the termination selection: against water penetration(Figure 31).Check 3.Center outer locking section over outer flue all joints very carefully to ensure no water pipe. Push down until locking tabs are firmly 2. Determine the number of chimney compo- Roof Pitch Model intrusion can take place. engaged. nents required,except chimney sections.This would include firestop spacers,stabilizers,roof Flat to 6112 1`81`6 flashing,etc. 6/12 to 12/12 F8F12 3.The effective heights of the components are: Locking Band n = Next,slide Figure 34 The Fireplace 45-3/8" deroofflashingoverextendedchimney - - P- section that previously has been installed above Waterproof CTD I Note:It is recommended that all exterior ex- MULTIPLE TERMINATIONS FTF8-12 = 10-1/4" the-roof opening in Step 4. FTF8 flashings Caulk Termination Chimney. posed metal fireplace components, such as FTF8 18 = 16 1/4" require flashing spacers.Slide flashing all the 13- terminations, flashings, storm collars and/or If more than one termination is located in the way down until the flashing base rests flat on _ flue be painted with a premium quality, high same chase or within the same general proxim- FTF8-36- = 34-1/4" the roof(Figure 29).Again,check the vertical temperature,rust preventative paint designed ity, we suggest they should be separated in FTF8 48 = 46-1/4" position of the chimney and the 2"minimum air for metal. This is especially important when distance at least 24"horizontally from flue cen space to combustibles. Figure 33 installationsaremadeinabnormall adverse or FTF8-CTD Termination = 4" g y ter to flue center and stacked or staggered corrosive environments such as near lakes, vertically at least 18"apart,from the termina- FTF8-CT1 Termination = 12"to 18" Figure 31 4.Pull up slightlyon CTD to ensure lockingjoint oceans or in areas with consistently high hu- tion of one smoke exit to the termination of FTF8 Chimney 9 FTF8 CT2 Termination = 15"to 23" Do Not Seal has firmly engaged. midity conditions Consult the paint manufac- another smoke exit(Figure 35•). Step 9. Security Chimneys locking bands, turers instructions for proper preparation and FTF8-CTDT Termination = 12"to 18" Flashing Spacers Using a FTF8-CTDT Chase Termination: application. CTD Model FLB, may be required if the chimney FTF8-CTT Termination = 6"to 14"• extends too high above the roof flashing.As a ia^ FTF8 Flashing Refer to specific installation instructions in- TEN FOOT RULE SUMMARY FTF8-ATT Termination = 8"to 14" , general rule,if the chimneyextends more than cluded with the FTF8-CTDT chase termination —J__" 6'above the roofflashing,the use of locking for clearance and installation details The minimum chimney height above the roof o Ts FTF8-S4 Stabilizer* = 3"* bands is advisable to strengthen the chimney and/or to adjacent walls and buildings is speci- o assembly.Align the locking band at the shim CTDT _ * Required for eve 30' of vertical chimney ne joint. Locking bands wrap aroundpipe Using aFTF8-CT7 Chase Termination: fled by all mayor building codes. q every y Y j 9 P crDT and/or 10'of offset chimney both joints equally covering the�oints of bopipe Figure 29 Refer to specific installation instructions in- If the horizontal distance from the peak of the - � - sections. Use the nut provided and TIGHTEN cluded with FTF8-CT1 chase terminations for roof is less then 10'•, the top of the chimney ia^ 4. Determine amount of chimney height re- snugly Do not overtighten as this might dam- clearance and installation details. must be at least 2'above the peak of the roof. :z4^ quire by subtracting total combined height of Note:Do notaulk or seal the ventilating open- age the chimney section(refer to Figure 31) all pre-selected components (fireplace and ings. y components onentsfromtotaldesiredheight.) w Note:If chimney extends more than S'above Using aFTF8-CT2 Chase Termination: If the horizontal distance from the chimney P Step 7—Secure flashing by nailing along the roofsurface, u wires are also recommended.• r, edge to the peak of the roof is more than 10'a Figure 35 `•' guy Refer to specific installation instructions in- chimney height reference point is established Reference Vertical Elevation Chart and deter- perimeterintoroof using 8d nails or equivalent: Use three 3 u wires,attach to lockingband P y g P If shingled roof,slide upper end and sides of ()g y cluded with FTF8-CT2 chase-terminations for on the roof surface 10' horizontally from the- " This suggestion is provided in the interest of mine thenumberofchimneysections(quantity 9 PP assembly,extend and secure to roof in a trian gg and length)required.-- roof:flashin under-shingles trim if neces- clearance and installation details. chimney edge.The top of the chimney must be• better o eration.If theterminations are located g ) q 9- 9 ( gular pattern (Figure 32). Guy wires are not P ,. ,• - - sa. seal the top at least 2' above this reference point. In all too close•to each other, smoke may migrate - - ry��__,_ P 9 supplied by the manufacturer. - y g SPECIAL OFFSET INSTRUCTIONS - • to therdofwith roof caulking.Cover nail heads Using a,FTF8-CTT Chase Termination: cases, the chimney cannot be less then 3' - from one flue into-the other. with roticaulking(Figure 30) hoof Ridge _ above the roof at the edge of the chimn6y. Refer to specific,installation instructions in- FTF8 CHIMNEY COMPONENT To clear any overhead obstructions,you may - cluded with FTF8-CTT chase terminations for The 2'in 10'rule is necessary in the interest of CALCULATIONS offset your chimney system using Security's clearance and installation details safety but does not ensure smoke-free opera- 301 offset and return elbows.Use two elbows- tion.Trees,buildmgs,ad�oming roof lin = �anoffsetelbowto-initiate the offset and a return es,ad of the com- The minimum installei• f eight o Using a FTF8-ATT Chase Termination: verse wind conditions,etc.,may require a taller elbow to terminate-it.A 30 offset elbow,an- chimney fireplace system is 15' 0". The maxi - lin in an direction,may be the first compo- Refer om o chimney should the fireplace not draft properly 9 9 Y Y P - Refer to specific installation'-instructions in- mum height is 60'0". nent used off the to of the fireplace flue collar. p (see Figure 34). P P • cluded with FTF8-ATT chase terminations for clearance and installation details izo° Figure 32 / r Figure 30 "10 NOTE DIAGRAMS&ILLUSTRATIONS NOT TO SCALE NOTE DIAGRAMS&ILLUSTRATIONS NOT TO SCALE / :11 v z n 0 0 a 10" 40 10" NOTES CHECK VALVE O O 28 12' FROM SKIMMER PUMP O 1. NO SPOIL SURCHARGE PERMITTED WITHIN 4 FEET OF EXCAVATION ATTHE SHALLOW END,OR FEET OF EXCAVATION AT THE DEEP END. U F 2. THIS POOL MEETS THE REQUIREMENTS OFANSI/N5PI-5 "AMERICAN NATIONAL STANDARD FOR RESIDENTIAL INGROUNDSWIMMING �--- LtJ A .� POOLS"AND 1996 BOCA CODE-SECTION 421. DIVING EQUIPMENT IS NOTALLOWED. J cc z O O 3. SWIMMING POOL SHALL BE COMPLETELY AND CONTINUOUSLY SUR ROUNDED WITH ABARRIERCONSTRUCTED LAW REQUIREMENTS OF �T �2 V cl 5PAC105 OF THE PESIDENTIALCODEOF NYS(2010)AND IN CONFORMITY WITH ALL SECTIONS OF THE SOUTHOLD TOWN CODE. ACCE55 —L TO DISPOSAL/ GATES SHALLCOMPLYWITH SECTION AG105.2OFTHE NYS RFSIDENTIALCODE AND BESELF CLOSING AND SELF LATCHINGANDOPEN AWAY v Q 00 DRYWELL FROM THE POOL AREA. W 10' 8 10 uj 4. DURINGCON5TPUCTION THE CONTRACTOR SHALL EkECTATEMPORARY BAPRIERAROUND THE EXCAVATION LAWTHECODEOFTHE ��' M TO W N OF SOUTHO LD. an DIVERTER O VALVE 5. POOL MUST BE EQUIPPED WITH AN APPROVED POOLALARM CAPABLE OF DETECTING A CHILD ENTERING THE WATERAND SOUNDING AN 3'4' AUDIBLEALARM WHEN DETECTED THAT 15 AUDIBLEAT POOL51DE AND ATANOTHER LOCATION ON THE PREMISES WHERE THE POOL 15 H2O LOCATED. THE ALARM MUST BE INSTALLED,MAINTAINED AND USED IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. THE ALARM MUST MEET ASTM F2208 "STANDARD SPECIFICATION FOR POOL ALARMS. THE DEVICE MV5TOPERATEINDEPENDENT(NOT FILTER ATTACHED TO OR DEPENDENTON)OF PERSONS. 6. POOL SUCTION FITTINGS(EXCEPT FOR SURFACE SKIMMERS)MUST BE PROVIDED WITH A COVER THAT CONFORMS TO ASME/AN51 A112.19.8M ORA MINIMUM 12"x 12"DRAIN GRATE ORA CHANNEL DRAIN SYSTEM. POOL CIRCULATION SYSTEM MUST BE EQUIPPED WITH ATMOSPHERIC VACUUM RELIEF IN THE EVENT THE GRATE COVERS LOCATED WITHIN THE POOL BECOME MISSING OR BROKEN. SUCH N VACUUM RELIEF SYSTEMS SHALL CONFORM WITH A5ME A112.19.17 OR BEA GRAVITY SYSTEM APPROVED BY THE TOWN OF SOUTHOLD. POOL SHALL BE PROVIDED WITH A MINIMUM OF SUCTION FITTINGS OF THE ABOVE MENTIONED TYPE. THE SUCTION FITTINGS SHALL BE SEPARATED BY A MINIMUM OF 3'AND MUST BE PIPED SUCH THAT WATER 15 DRAWN THROUGH THEM SIMULTANEOUSLY THROUGH A Q) Z VACUUM RELIEF-PROTECTED LINE TO THE PUMP(OR PUMPS) VACUUM/PRESSURE CLEANING FITTINGS SHALL BE IN AN ACCE551BLE Cl g_per POSITION,MINIMUM OF 6"AND NO GREATER THAN 12"BELOW THE MINIMUM OPERATIONAL WATER LEVEL OR BEAN ATTACHMENT TO V H2O .CD THE SKIMMER/SKIMMERS. �3 7. ALL ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 70(NEC)PRINCIPALLY ARTICLE 680 AND THE NYS RESIDENTIAL rtr CODE SECTION 4102 THROUGH 4106. ALL ELECTRICAL DEVICES MUST BEAPPROVED BY UNDERWRITERS LABORATORIES AND BE PROTECTED A TO RETURNS BY GROUND FAULT CURRENT INTERRUPTER(GFCI) CURRENT CARRYING ELECTRICAL CONDUCTORS EXCEPT FOP THOSE PROVIDING is POWER TO POOL LIGHTING AND POOL EQUIPMENT SHALL MEET THE SEPARATION REQUIREMENTS OF TABLE E4103.5. ALL METAL "Q CHECK VALVE ENCLOSURES,FENCES OR RAILINGS NEAR ORAD)ACENTTO THE SWIMMING POOL THAT MAY BECOME ELECTRICALLY CHARGED DUE TO ru CONTACT WITH AN ELECTRICAL CIRCUIT SHALL BE EFFECTIVELY GROUNDED. 0 O U 8. WATER SOURCE FILLING THE POOL SHALL BE EQUIPPED WITH A BACKFLOW PROTECTION DEVICE LAW NY5 PLUMBING CODE 608. QyJ O O ,p 9. ALL PIPING 15 DIAGRAMMATIC UNLESS OTHERWISE STATED. Ln -G vVi g PLUMBING SCHEMATIC 10.WALKS IFPROVIDEC)SHALL BENONSLIP AND SLOPE AWAY FROM POOL EDGE. o Q N.T.5. 11.A MEANS OF EGRESS FOR DEEP AND SHALLOW ENDS MUST BE PROVIDED IAW ANSL/NSPI-5 SECTION 6. C' CL N PLAN 12.CONTRACTOR TO PLACE THE POOL LAW TOWN OF SOUTHOLD CODE SETBACKS. SCALE: 1/8"=1'-0' 13.ALL DRAINAGE FROM THE POOL SHALL BE MAINTAINED ON THE SUBJECT PROPERTY. N 15.THE DESIGN 15 BASED ON A DRAINAGE SOIL WITH<10.SILT. GROUND WATER SHALL NOT EXIST WITHIN THE EXCAVATION. IF GROUND 0 WATER EXISTS WITHIN 6'-O"FROM GRADE,DEWATERING FACILITIES WILL BE REQUIRED. NO t 16.ALLGAS AND OIL HEATERS(IF INSTALLED)FORTHE INGROUND SWIMMING POOLSHALL BE NATIONAL APPLIANCE ENERGY N POURED CONCRETE CONSERVATION ACT(NAECA)COMPLIANT. POOL HEATERS SHALL BE TESTED IAW AN51221.56 AND SHALL BE INSTALLED LAW t WALLSAND STEPS MANUFACTURERS SPECIFICATIONS. OIL FIRED POOL HEATERS SHALL BE TESTED IAW UL726. POOL HEATERS SHALL BE LOCATED OR M 2'-2" GUARDED TO PROTECTAGAINSTACCIDENTALCONTACTOF HOT SURFACES BY PERSONS. POOL HEATERS SHALL BE PROVIDED WITH TEMPERATURE AND PRESSURE-RELIEF VALVES. FOR HEATERS NOT PROVIDED WITH AN INTEGRAL BYPASS SYSTEM. A BYPASS LINE SHALL BE INSTALLED FROM INLET TO OUTLET TO ADJUST WATER FLOW THROUGH THE HEATER. POOL HEATERS SHALL BE PROVIDED WITH THE r 1 FOLLOWING ENERGY CONSERVATION MEASURES: COPING AND WALKWAY 16.1. ALL POOL HEATERS SHALL BE EQUIPPED WITH AN ON-OFF SWITCH MOUNTED FOR EASY ACCESS TO ALLOW SHUTTING OFF THE Qy (BY OTHERS) OPERATION OF THE HEATER WITHOVTAD)USTING THE THERMOSTAT SETTING AND TO ALLOW RESTARTING WITHOUT RELIGHTING THE GRADE PILOT LIGHT. �h 2'to 4'SAND BOTTOM 16.2. HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH A POOL COVER(EXEMPTED FROM THIS REQUIREMENTARE OUTDOOR POOLS V WATER LINE DERIVING 20%OF THE ENERGY FOR HEATING FROM RENEWABLE SOURCES AS COMPUTED OVERAN OPERATING SEASON) 7 L 16.3 TIME CLOCKS SHALL BE INSTALLED 50 THE PUMP CAN BE SEFTO RUN DURING OFF-PEAK ELECTRICAL DEMAND PERIODS AND CAN BE SET �w • /�r TO RUN THE MINIMUM TIME NECESSARY TO MAINTAIN THE POOL WATER INA CLEAN AND SANITARY CONDITION LAWAPPLICABLE 1M� UNDISTURBED EARTH SANITARY CODE OF NEW YORK STATE. W •,;••••� •�:.'\/ W i=� � SECTION A . ....• . 17.THIS DRAWING I5 FOR STRUCTURAL SHELL ONLY. ALLACCES50RIESANDAPPURTENANCE5AREDEFINEDBYOTHERS. A 3500 P51 POURED CONC. d w Q T 3/8"REBAR. 3)TYP. \� 18.BACKFILL WITH CLEAN EARTH,FREE OF ROOTS AND DEBRIS. DO NOTALLOW THE HEIGHT OF BACKFILL TO EXCEED THE HEIGHT OF THE Z C } e•,. .• •; : \�� WATER IN THE POOL BY MORE THAN 8, OR THE WATER TO EXCEED BACKFILL BY MORETHAN 8" —t4 - Zw VINYL LINER 4 �\ 19.PLACE CONCRETE ON SANDY TO LOAM 501 L. REMOVE ANY CLAY DEPOSIT AND COMPACT CLEAN BACKFILL "' la ^^ O 2"T04"SAND • /\ E • ` �/� 21.THERE IS NO MAIN DRAIN IN THIS POOL. SUCTION FOR POOL WATER CIRCULATION 15 PROVIDED BY THE SKIMMERS ONLY, THIS MEETS t = 0 r �� TOP OF WALL WATER LINE a ��� REQUIREMENTS OF RC-SECTION AG106 FOR w ENTRAPMENT PROTECTION. M Y aj ,\���\�� �� 22.THE POOL WAS DESIGNED LAW THE FOLLOWING: N C F LL. b 22.1. THE BUILDING CODE OF NEIN YORK STATE(2010) w 1 a t� 22.2. THE ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(2010) AWA 'o 22.3. THE FUEL GAS CODE OF NEW YORK STATE(2010) VERTICAL 3/8'REBAR 0 3'O.C. 22.4. THE RESIDENTIAL CODE OF NEW YORK STATE(2010) (NOT5HOWN) 22.5. THE NEW YORK STATE SANITARY CODE. 22.6. ANSI/NSPI-5 STANDARD FOR RESIDENTIAL IN-GROUND SWIMMING POOLS. 22.7. BOCA CODE-SECTION 421. 22.8. CODE OF THE TOWN OF SOUTHOLD. WALL SECTION N.T.S. SECTION B �B rE? r 5 f"3 00 G 0 0 Ail