Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
40977-Z
Q�Sv6f�t, �pG Town of Southold 1/4/2017 a� y P.O.Box 1179 53095 Main Rd oy o`r� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38701 Date: 12/12/2016 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 425 S Harbor Rd, Southold SCTM#: 473889 Sec/Block/Lot: 75.4-29 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/1/2016 pursuant to which Building Permit No. 40977 dated 9/8/2016 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels on accessory garage as applied for. Corrected 1/4/2017 - solar panels are not on the dwelling just the accessoH garage. The certificate is issued to Suprenant,Adam&Klahre,Laura of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40977 11/2/2016 PLUMBERS CERTIFICATION DATED Authorized Signature ��ggllFFQd,QG� Town of Southold 12/12/2016 a P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38701 Date: 12/12/2016 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 425 S Harbor Rd, Southold SCTM#: 473889 Sec/Block/Lot: 75.4-29 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/1/2016 pursuant to which Building Permit No. 40977 dated 9/8/2016 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels on existing one family dwelling as applied for. The certificate is issued to Suprenant,Adam&Klahre,Laura of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40977 11/2/2016 PLUMBERS CERTIFICATION DATED Authorized Signature o�g�FFO(q- TOWN OF SOUTHOLD 49, BUILDING DEPARTMENT C- 2 TOWN CLERK'S OFFICE o • SOUTHOLD, NY oa'sf BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40977 Date: 9/8/2016 Permission is hereby granted to: Suprenant, Adam PO BOX 1034 Cutchogue, NY 11935 To: install roof-mounted solar panels on as applied for. At premises located at: 425 S Harbor Rd, Southold SCTM # 473889 Sec/Block/Lot# 75.-4-29 Pursuant to application dated 9/1/2016 and approved by the Building Inspector. To expire on 3/10/2018. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 r1j /" ui�in-4nspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and "pre-existing"land uses: 1 Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50 00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00,Commercial $15.00 Date. 8/30/2016 New Construction: Old or Pre-existing Building: x (check one) Location of Property: 425 South Harbor Rd Southold House No. Street Hamlet Owner or Owners of Property. Adam Suprenant Suffolk County Tax Map No 1000, Section 75 Block 4 Lot 29 Subdivision Filed Map. Lot: Permit No. ��� Date of Permit. Applicant: Green Logic LLC Health Dept.Approval: Underwriters Approval- Planning Board Approval: Request for: Temporary Certificate Final Certificate. x (check one) Fee Submitted: $ 50.00 n t v Applicant Signature pf SO�j��®� Town Hall Annex ® Telephone(631)765-1802 54375 Main Road CP Fax(631)765-9502 P.O.Box 1179 roger.riche rtic7t town.southoId.ny.us Southold,NY 11971-0959 COU , BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Suprenant Address: 425 S.Harbor Road City: Southold St: New York Zip: 11971 - Budding Permit#: 40977 Section: 75 Block. 4 Lot 29 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Green Logic LLC License No: 43858-ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency FixturesTime Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: 4.578 KW Roof Mounted Photovoltaic System to Include 14-SPR-E20-327 Panels, 1- SB 5000 Inverter Notes: Inspector Signature: Date: November 2, 2016 i 0-81-Cert Electrical,Compliance Form.xls �--- OF SO(/TyO� G • O cou TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) REMARKS: DATE 7/ INSPECTOR Pacifico Engineering PC _ _� —___ Engineering Consulting 700 Lakeland Ave, Suite 2B t tcl, _ Ph- 631-988-0000 Bohemia, NY 11716 P Fax: 631-382-8236 www.pacificoengineering.com .- FSI' ' RI, CSC solar@pacificoengineering.com October 6, 2016 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Adam Suprenant Section: 75 425 South Harbor Road Block: 4 Southold, NY 11971 Lot: 29 1 have reviewed the solar energy system installation at the subject address on October 6, 2016.The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2010 NYS Building Code, and ASCE7-05. - -- To my best belief and knowledge, the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice, with the view to the safeguarding of life, health, property and public welfare. Regards, Ralph Pacifico, PE Professional Engineer /I P�P\A 0661 g2 c,1 ���.^ V A v Ral e�ftc���(� ngineer D D NY 0 04744306 DEC 9 2016 BUILDING DEPT• TOWN OF SOUTHOLD FIELD INSFR=Obi R. ORT AAS C01v�5 ' FpUl 4,ftoN (1ST) �'OUND�TXQN (2N13) � ROUGE!FRANnNQ & PLUIYM N'G 9 ENOLATIGN PER N,Y. STATE RNERGY GODB FINAL •ter. TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BU.TLDI9G DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 7654802 Planning Board approval FAX: (631) 765-9502 Suryey SoutholdTown.NorthFork.net PERMIT NO. Cheek Septic Form N Y.S.D.E.C. Trustees Flood Permit Examined ,20 Storm-Water Assessment Form Contact: Approved '20 Mail to- GreenLogic LLC Disapproved a/c 425 County Road 39A, Southampton, NY 11968 �) Phone: 631-771-5152 Expiration (/ 20 __a Bui�i�ctor SEP 2MA PPL ION FOR BUILDING PERMIT Date August 30 , 20 16 BUILDING DEPT. INSTRUCTIONS TOWN OF SOUTHOLD a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale. Fee according to schedule b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the propprty have been enacted in the interim,the Building Inspector-may authorize, in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other-applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. GreenLogic LLC (Signature of applicant or name,if a corporation) 425 County Road 39A, Southampton, NY 11968 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Contractor Name of owner of premises Adam Suprenant (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Nam nd title of corporate officer) Builders License No. 40227-H Plumbers License No. Electricians License No. 43858-ME Other Trade's License No. 1. Location of land on which proposed work will be done: 425 South Harbor Rd Southold House Number Street Hamlet County Tax Map No. 1000 Section 75 Block 4 Lot 29 Subdivision v;F�il�ed;Map I�lo '' .4 Lot Ir jl I 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: , a. Existing use and occupancy Single family dwelling b. Intended use and occupancy Single family dwelling 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work Roof mounted solar electric system (Description) 4. Estimated Cost $22,850.00 Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth _ Height Number of Stories Dimensions of same structure with alterations or additions: Front,j ; Rear Depth Height Number of.Stories� ` ' p ° 8. Dimensions of entire new construction: Front Rear Depth r� 1 Height Number of Stories ' Z... :tier''=:a S.�'''.-d'u �„':� 3 n'!•l v 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO x 13. Will lot be re-graded? YES NO x Will excess fill be removed from premises?YES NO x 425 South Harbor Rd 14.Names of Owner of premises Adam Suprenant Address Southold, NY 11971 Phone No. 631-948-1098 Name of Architect Parifirn FnginpPri g, F r Address700 Lakeland Ave,Bohemia,N hone No 6-i1-988-0000 Name of Contractor GreenLogic LLC Address a?S county Road 39A Phone No. 631-771-5152 Southampton, NY 11968 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO x * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO x * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO x * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Nesim Albukrek being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contractor (Contractor, Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have perfor►ned the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sw to before me th' da of 20� Notary Public TAMARA L.ROMERO F— Signature of Applicant Notary Public,State of New York No.01 R06217368 Qualified in Suffolk County Commission Expires 210812018 �o��of so�ryo! i o Town Hall Annex ] Telephone(631)765-1802 54375 Main Road y (631)765 g5 P.O.Box 1179 G @ roger.richertCat�awn.soutfioQ .ny.us I Southold,NY 11971-0959 S BUILDING DEPARTMENT TOWN OF SOUTHOLD ' APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY-- Tamara Romero Date: 8/30/2016 Company Name: GreenLogic LLC Name: Robert Skypala ' License No.: 43858-ME Address- 425 County Road 39A, Southampton, NY 11968 Phone No.: 631-771-5152 + JOBSITE INFORMATION: (*Indicates required information) *Name: Adam Suprenant i *Address: 425 South Harbor Rd, Southold, NY 11971 i *Cross Street: Main Rd *Phone No.: 631-948-1098 Permit No.: Tax-Map District: 1000 Section: 75 Block: 4 Lot: 29 ~— *BRIEF DESCRIPTION OF WORK(Please Print Clearly) Root mounted solar electric system ` f 14 SunPower SPR-E20-327 Modules 4.578 kWh 1 SMA SB5000TL-US-22 inverter (Please Circle All That Apply) *Is job ready for inspection: YES NO Rough In Final *Do you need a Temp Certificate: - - Temp Information (If needed) I *Service Size: 1 Phase 313hase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead ' Additional Information: PAYMENT DUE WITH APPLICATION i2-Request for Inspection Form Scott A. Fussell SUPERVISOR 1\\I[A1vAAG)EM IENT 5pUTHOLL7 TOWN HALL-P.O.Sax 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 � 'own of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BL: C01,M 'LL" ID BY THE APPLICANT ) 1 DOES THIS 1)RQJh--C;'I" IN"VOIXE ANY O 'I'FIE FOI..Lo`WINQ (CHECK ALL THAT APPLY) Yep No r ftl sE ®a A. Clearing, grubbing, grading or stripping of land which affects more : than 5,000 square feet of ground surface, ti ®El B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ,7. E][3 C. ,Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. 4{ ®� D. Site preparation within 100 feet .of wetlands, beach, bluff or coastal ?' erosion hazard area. ; € ®Q E. Site preparation within the one-hundred-year f loodplain as depicted 1 on FIRM Map. of any �,vatercourse. { ®[D F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management _; Control Plan was received by the Town and the proposal includes :t €;s in-k-ind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date tt County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stoimwater Management Control Plan and a completed Check List Form to the•Buiiding Department with your Building Permit Application. Date APPLICANT 3}Y lettc Chi Tier,De:•Ign P7'nfc 5 conal-tlgsl�t.t oniract ,()thrY) � : i t} �� Iii t}iS£t741 Greent-ogic LLC (Nesim Albukrek) 75 4 29 8/30/2016 �. Scotian Bluck Lai FOR BUILDING DLPAR?MENT USE. ONLY 631-771-5152 ,$s Cnnsart lnfc7msnorr .<, <- , 7,1,0" N...NO Reviewed Bv: 3' i;I Property!Address/Location ofConstruction Work: i — — — — — — _ — }' 425 South Harbor Rd, Southold, NY 11971 i `approved for processing Building Permit. °3 i ® 5tormwater Mana;ement Control Plan Not Required. ; € ` , ® `Storniwater Management Control Plan is Requited. -;[ (Forward to Eng tneeting Department for Review.) FORIM SMC<P-I'OS NI A Y 2014 3 GREENLOGICO ENERGY August 30, 2016 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Dear Building Inspector: Please find attached a building permit application on behalf of Adam Suprenant who has engaged us to install a roof-mounted solar photovoltaic (PV) electric system at his home at 425 South Harbor Rd;Southold, NY 11971. In connection with this application, please find attached: D [EC[ED'V[E D • Building Permit application SEP - 1 2016 • A Storm Water Assessment Run-off Form • Certificate of Occupancy Application BUILDINGDEPT. • Application for Electrical Inspection • TOWNOFSOUTHOLD • 2 Surveys of the Premises • 4 Engineer's Reports (2 originals and 2 copies) • 2 One Line Electrical Schematics • 2 Spec. sheets of the solar panels (SunPower 327) • 2 Spec. sheets of the inverter (SMA SB5000) • 2 Code Compliant Manuals for Racking System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200 ($50 Building Permit/$50 CO/$100 Electrical) Please let us know if you need anything else in connection with this application. Yours truly, Tamara Romero Account Manager GreenLogic LLC 631-771-5152 ext. 110 GREENLOGIC LLC -www.Green Logic.corn Tel: 877 7714330 Fax: 877 771.4320 SOUTHAMPTON ROSLYN HEIGHTS 425 County Rd 39A 200 S Service Rd ,#108 Southampton, NY 11968 Rosyln Heights, NY 11577 oF soUr�®� � o Town Hall Annex Telephone(631)765-1802 54375 Main Road N Fax(631)765-9502 P.O.Box 1179 G ® Q Southold,NY 11971-0959 'Q l�COUNT November 14, 2016 BUILDING DEPARTMENT TOWN OF SOUTHOLD GreenLogic LLC 425 County Rd 39A Southampton NY 11968 Re: Suprenant, 425 South Harbor Rd, Southold TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy. NOTE: Certification required from an architect or engineer stating the panels were installed per NYS Building Code Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 411/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 40977 - Solar GREENLOGIC® ENERGY December 5, 2016• The Town of Southold Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Re: Building Permit No. 40977 Adam Suprenant 425 South Harbor Rd, Southold, NY To the Building Inspector: Enclosed please find the Engineer's Certification Letter and the Town of Southold Certificate of Compliance for Adam Suprenant's solar electric system, which we installed at the above reference address. Please arrange to send him the Certificate of Occupancy and close out the building permit. Please let me know if you have any questions about the installation. Sincerely, Tamara Gajewski Account Manager GreenLogic LLC 631-771-5152 Ext. 110 D CCS DSI[ DD DEC 9 2016 BUHMING DAFT. TOWN OF SOU IE[OLD GREENLOGIC LLC .www.GreenLogic.com Tel: 877 771.4330 Fax: 877.771 4320 SOUTHAMPTON ROSLYN HEIGHTS 425 County Rd 39A 200 S Service Rd , #108 Southampton, NY 11968 Rosyln Heights, NY 11577 ..... ........... .... .................... �N Suffolk County Executivels 0 ce of Consumer Affairs VETERANS MEMORIAL HIGHWAY HAUPPAUGE, NEWYORK 11788 DATE ISSUED: 5/25/2006 No. 40227-H N SUFFOLK COUNTY Home Improvement Contractor License This is to certifv that MARC A CLEJAN doing business as GREEN LOGIC LLC having furnished the requirements set forth in accordance with and subject to the provisions of applicable laws,rules and regulations of the County of Suffolk, StAte of New York is hereby licensed to conduct business as d HOME IMPROVEMENT CONTRACTOR,in the County of Suffolk. ........ Additional Rusinesses NOT VALID WITHOUT DIEPARTMENTAL SEAL AND A CURRENT CONSU1�IER AFFAIRS ID CARD Director f. 40* 1% Q-o" iC:' .3 ..... 1 Z7 4 N CERTIFICATE OF LIABILITY INSURANCE F DATE(MMIDDIYYYY) 6103116 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Brookhaven Agency,Inc. Brookhaven Agency,Inc. PHONEINC No 631 941-4113 FAx 631 9414405 128 Old Town Road Suite C EMAIL brookhaven.agency@verizon.net PO Box 860 PRODUCER ClIqT OMFR in a. East Setauket NY 11733 INSURERS AFFORDING COVERAGE NAIC a INSURED INSURER A HDI-Gerling America Insurance Co. Greenlogic,LLC INSURER B Merchants Preferred Insurance Co. 425 County Road 39A,Suite 202 INSURER C First Rehab Life Insurance Co. Southampton,NY 11968 INSURER D•Ace American Insurance Co. INS REE• AGCS Marine Insurance Co. INSURER F: National Liability 8r Fire Insurance Co. COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE DL UBR POLICY NUMBER POLICY EFF POLICY EXPLTR LIMITS GENERAL LIABILITY EACH OCCURRENCE $1,000,000 A X COMMERCIAL GENERAL LIABILITY X X EGGCCO00076916 01/31/16 01/31/17 DAMAGE TO RENTED $100,000 CLAIMS-ME X]OCCUR MED EXP(Any oneperson) $6,000 X XCU PERSONAL&ADV INJURY $1.000,000 X Contractual Llab GENERAL AGGREGATE s2,000,000 GEML AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMPIOP AGG s2,000,000 POLICY X PRO- LOC S AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT (Ea accident) $1,000,000 B X ANY AUTO CAP1043666 8111/16 8/11/16 BODILY INJURY(Per person) S ALL OWNED AUTOS BODILY INJURY(Par accident) $ SCHEDULED AUTOS PROPERTY DAMAGE $ X HIRED AUTOS (Par accident) X NON-OWNED AUTOS S S X UMBRELLA UAB X OCCUR EACH OCCURRENCE $1,000,000 D EXCESS U40 CLAIMS.MADE X X N10905989 001 01/31/16 01/31/17 AGGREGATE $1,000,000 DEDUCTIBLE S X $10,000 $ WORKERS COMPENSATION XWC STATU- OTH- AND EMPLOYERS'LIABILITY F ANY PROPRIETORIPARTNERIEXECUT YIN V9WC794777 6/16/16 6/15/17 E L EACH ACCIDENT S 1 O00 000 OFFICERIMEMBER EXCLUDED? N I A (Mandatory In NH) E L.DISEASE-EA EMPLOYEE $1,000,000 H a dgON be under TI I E L.DISEASE-POLICY LIMIT $1 000 000 C I NYS Disability D261202 4111116 4111/17 Statutory Limits E Installation Floater/Pro a MX193071832 1411SMS 14116117 1$600,000 $1,000 Ded DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(Attach ACORD 101,Additional Remarks Schedule,If more space Is required) CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53096 ROUTE 26 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE p ©1988-2009 ACORD CORPORATION. All rights reserved. ACORD 25(2009109) The ACORD name and logo are registered marks of ACORD STATE OF NEW YORK WORKERS' COMPENSATION BOARD CERTIFICATE OF NYS WORKERS' COMPENSATION INSURANCE COVERAGE Ia.Legal Name&Address of Insured(Use street address only) 1b.Business Telephone Number of Insured Greenlogic LLC 631-771-5152 425 County Rd 39A Ste 202 Ic.NYS Unemployment Insurance Employer Southampton NY 11968 Registration Number of Insured Id.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is or Social Security Number spec Bally limited to certain locations in New York State,I.e.,a 203801194 Wrap-Up Policy) 2.Name and Address of the Entity Requesting Proof of 3a. Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) National Liability&Fire Insurance Company Town Of Southold 3b.Policy Number of entity listed in box"la" Building Department V9WC794777 53095 Route 25 3c. Policy effective period Southold,NY 11971 06/15/16 to 06/15/2017 3d. The Proprietor,Partners or Executive Officers are included. (Only check box irall partners/officers included) X all excluded or certainpartners/officers excluded. This certifies that the insurance carrier indicated above in box "3" insures the business referenced above in box "la" for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"T'. The Insurance Carrier will also not.the above certificate holder within 10 days IF a policy is canceled due to nonpayment ofpremiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. ('These notices maybe sent by regular mail.) Otherwise,this Certificate is valid for oneyear after this form is approved by lite insurance carrier or Its licensed agent,or until the policy expiration date listed in box"3c'r,whichever is earlier. Please Note: Upon the cancellation of the workers' compensation policy indicated on this form, if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers' Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by:NICHOLAS ZULKOFSKE (Print n of authorized representative or licensed agent of insurance carrier) Approved by: May 23 2016 (Date) Title: Authorized Agent Telephone Number of authorized representative or licensed agent of insurance carrier: 631-941-4113 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2(9-07) www.wcb.state.ny.us Workers' Compensation Law Section 57. Restriction on issue of permits and the entering into contracts unless compensation is secured. 1. The head of a state or municipal department,board,commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter,and notwithstanding any general or special statute requiring or authorizing the issue of such permits,shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that compensation for all employees has been secured as provided by this chapter.Nothing herein,however,shall be construed as creating any liability on the part of such state or municipal department,board, commission or office to pay any compensation to any such employee if so employed. 2. The head of a state or municipal department,board,commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter,notwithstanding any general or special statute requiring or authorizing any such contract,shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that compensation for all employees has been secured as provided by this chapter. C-105.2(9-07)Reverse -t � A r rt - f' .>., ♦�:7 _f r:�Wx-. 1 Suffolk Coun Executive's Office of Consumer Affairs ry VETERANS MEMORIAL HIGHWAY HAUPPAUGE, NEWYORK 11788 1 TED: No. 43858-ME DATE ISSL 12/10/2007 / Ir 1 SUFFOLK/ T-. If c Master r' / JrThis is to certify that { doing business GREENLOGIC LLC having given satisfactory evidence of competency,is hereby licensed as MASTER ELECTRICIAN in accordance w ith and subject to the provisions of applicable and regulations of the County of Suffolk, State of New York. j Additional Businesses NOT VALID WITHOUT DEPARTMENTAL SEAL ANDA'CURRENT CONSUMER AFFAIRS 11)CARD L\ J � - Director \. r tv l ..f lC.. 'e:...*' 1`�-v :_ sx & � J c,.,r• ,fL`� Z.r' x,+ .fil l(' 'y.el..:' �\-_cr.J/�i� J !_ ,w .: �Z:: j s - N SURVEY OF PROPERTY O � LOT s .A T SO UTHOLD 114 R r F 0 �G�EE� Ho�SEs TO WN OF SO UT �IOLD c A A50 �- ^� Y 1. Y. " � _ & �jsuic WMR) . - SUFFOLK COUNTY, 1000—'1v-94`=29 OCTOBER 28,2002 (EASEMENT) P P gyp• —# 1 DEC. 9,2002 REVISIONS GPS P' PVBE _X —X �C x r' FEB. 5,200.3 REVISIONS r V*vt1'1�G < D� x�—•g5`�x REBAR J r j JAN. 23, 2004 (FINAL) -DEC. 5,2005(PRO, , ADDI T.) APRIL 21? 0 4ov. St1 -0 1 1 APRIL 28, 151 R.O.W.) N�5 j 1 1 REBAR �- 1 & vOLOSIK FREE FOW 2�.8' sTa PATIO LOT 1 4 ' LOT 2 Q � b� °D CERTIFIED TO: DIRT'DF2IYEYl&Y Ot} {( 1 ` O ' ip J 1.62-63, gg.00` 0'20 T Q r _f o ADAM SUPRENANT N86'22fl!'E ' 1 230.43• m LAURA KLAHRE _ _ CHICAGO TITLE INSURANCE SERVICES,LLC 200'-[5* etocr-dry w S, 120' W FARM CREDIT EAST,ACA. co roH - Qo =HYDRANT N _ S 201-88, gE1tlE�T A d` s gI r r 3'•� A,= STAKEPow ' Fc 75.2 D LLIJAG (pU6L1C t 1K= MONUMENT W XA ,4 REBARNZ S O= POLE VR� F r LOT NUMBERS ARE REFERENCED TO " MAP OF MINOR __ f. �' _ p ` SUBDIVISION OF PROPERTY SURVEYED FOR SAL VA TORE ,�`� ,. Ci CATAPANO' FILIrD IN THE OFFICE OF THE SUFFOLK CLERK ON JUNE 25, 1992 AS MAP NO. 9238 N. Y. LIC. NO. 49618 ANY AL7rRATlON OR ADDITION TO IRIS SURVEY IS A wOL4710N 1.83'x® ACRS �'ECONIC %EYORS, P.C. OF SECTION 72090E THE NEW YORK STATE EDUCAAON LAW. AREA= 80.022 SO.: F i0'. EXCEPT AS PER SECTION 7209—SUBDI1ISION 2. ALL CERTIFICATIONS (631) 765-5020 FAX (631) 765-1797 p. BOX 909 HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IF SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF THE SURVEYOR i ~? 1230 TRAVELER STREET ®�_��3 WHOSE SIGNATURE APPEARS HEREON. SOUTHOLD, N.Y. 11971 APPROVED AS MUD ELECTRICAL DATE: � 6.0.# INSPECTION REQUIRED FEE: � � BY: NOTIFY BUILDING DEPART AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING RETAIN STORM WATER RUNOFF s. INSULATION PURSUANT TO CHAPTER 236 4. FINAL - CONSTRUCTION MUST OF THE TOWN CODE-.-,, BE COMPLETE FOR C.O. ALL CONSTRUCTION SMALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF `S6tf�OCQTO�{QZB�'� 5'DOTAOCD�'OG7N'P17�(IfIV�OARD ��R�D"�Giri<tTRt�S�f E3 OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY ` Acifico Engineering PC ____ Engineering Consulting 700 Lakeland Ave, Suite 2B _ (C "= Ph: 631-988-0000 Bohemia, NY 11716x ' P Fax: 631-382-8236 www.paciflcoengineering com _ �G solar@pacificoengineering.com -- - August 16, 2016 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Adam Suprenant Section: 75 425 South Harbor Road Block: 4 Southold, NY 11971 Lot: 29 I have reviewed the roofing structure at the subject address. The structure can support the additional weight of the roof mounted system. The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2010 NYS Building Code, and ASCE7-05 when installed in accordance with the manufacturer's instructions. Roof Section A Mean roof height 12 ft Pitch 9 3/4 in/12 Roof rafter 2x8 Rafter spacing 24 inch on center Reflected roof rafter span 6.1 ft Table R802.5.1(1)max allowable 13.8 ft The climactic and load information is below: CLIMACTIC ANDWind Live load, Exposure Ground Speed,3 pnet30 per point DESIGN Snow Load, pullout Fastener type CRITERIA Category Pg sec gust, ASCE 7, load,Ib mph psf Roof Section A C 20 120 30 307 S-5! Clamp OF NEIL, Weight Distribution AD �'o array dead load 3 5 psf co 4P�P , load per attachment 220.0 Ib 0 Subject roof has one layer of shingles Panels mounted flush to roof no higher than 6 inches above surface. >w Ralph Pacifico, PE NCO 0 661 Professional Engineer Ralph gineer NY 06618 04744306 GREENLOGIC" ENERGY GreenLogic,LLC Approved Adam Suprenant 425 South Harbor Road Southold,NY 11971 Surface#A: Total System Size-4.578kW Array Size.4 578kW 1 string of 7 and 1 string of 7 on SB- 5000TL Azimuth: 161* Pitch:39° Monitoring System. Sun Power Panel/Array Specifications: Panel.SPR-E20-327 Racking:Sun Power Invisimount Panel:61.39"X 41 18" Array:20'10 7/8"X 11'11 3/" Surface.24'10"X 14' x x x x x Magic#: Invisimount Legend: ® 14 Sun Power 327W Panels ® Sun Power Invisimount Rad • S5-S Clamp B Q NC550S—1.5".032ga 15"O C. Standing Seam Roof Notes: Number of Roof Layers- 1 Height above Roof Surface:4" Materials Used-Eco-Fasten,Sun Power, SMA Added Roof load of PV System 3.5psf Engineer/Architect Seal: XI OF MEFtV N PA C� O CO �Crzass. �� rn SOA 66182 SS10�P�' Drawn By:MMB Drawing#1 of 5 Date:8/15/2016 REV:A Drawing Scale:3/16"= 1.0' (-Go�� GREENLOGICO ENERGY GreenLogic,LLC Approved Adam Suprenant 425 South Harbor Road Southold,NY 11971 Surface#A: Total System Size-4.578kW Array Size-4.578kW 1 string of 7 and 1 string of 7 on SB- 5000TL Azimuth:161° Pitch:39° Monitoring System: Sun Power Panel/Array Specifications: Panel.SPR-E20-327 Racking Sun Power Invisimount Panel:61 39"X 41.18" 4t I Array.20'10 7/8"X 11'11 3/" Surface:24'10"X 14' Magic#. Invisimount Legend: ® 14 Sun Power 327W Panels Sun Power Invisimount Rad • S5-S Clamp NC550S—1 5".032ga 15"O.0 INJ Standing Seam Roof Notes Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,Sun Power, SMA Added Roof load of PV System:3.5psf Engineer/Architect ySeal: OF N E / P� ®�� E: �aarp 066182 A�OFESSIO'oP� Drawn By MMB Drawing#2 of 5 r Date:8/15/2016 REV:A Drawing Scale:3/16"= 1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Adam Suprenant 425 South Harbor Road Southold,NY 11971 Surface#A: Total System Size:4.578kW Array Size 4 578kW 1 string of 7 and 1 string of 7 on SB- 5000TL Azimuth. 161* Pitch.39° Monitoring System: SunPower Panel/Array Specifications: Panel SPR-E20-327 Racking.SunPower Invisimount Panel 61 39"X 41 18" ------------ 4� Array.20'10 7/8"X 11'11 3/" 2 Surface:24'10"X 14' Magic#:Invisimount Legend: ® 14 SunPower 327W Panels ZL -------P SunPower Invisimount Rail 2 1 •- S5-S Clamp NC550S—1 5".032ga 15"O.0 Standing Seam Roof Notes: Number of Roof Layers-1 1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower, SMA Added Roof load of PV System 3.5psf Engineer/Architect Seal: N �0 066182 �ROFESSIONP�" Drawn By:MMB Drawing#3 of 5 Date:8/15/2016 REV:A Drawing Scale-3/16"=1 0' No Vent Pipes Will Be Covered By The Solar Array GRA SRL®GIC® ENERGY GreenLogic,LLC Approved Meter Adam Suprenant 425 South Harbor Road Southold,NY 11971 Total System Size:4.578kW Array Size 4.578kW 1 string of 7 and 1 string of 7 on SB- 5000TL Azimuth.161° 1 Inverter Located On Pitch:39° Monitoring System• N West Wall As Close As Sun Power Practical To Water Main Panel/Array Specifications: Panel:SPR-E20-327 Racking.Sun Power Invisimount Panel.61.39"X 41.18" Array.20'10 7/8"X 11'11 3/a" Surface:24'10"X 14' Magic#:Invisimount Legend: ® 14 Sun Power 327W Panels ® Sun Power Invisimount Rad A S5-S Clamp B NC550S—1.5".032ga 15"O C Standing Seam Roof N otes Number of Roof Layers- 1 Height above Roof Surface:4" Materials Used:Eco-Fasten,Sun Power, SMA I Added Roof load of PV System 3.5psf Engineer/Architect Seal: I pF NEty -----�---L-----� '�� yob co P�PN P� r— � saved n �O 0661 B9- lG= 18" Service Walkway ?YOFESSIONP� 14 Sun Power 327 Drawn By:MMB Drawing#4 of 5 Panels Date:8/15/2016 REV:A Drawing Scale:3/32"= 1.0' GREENLOGICO ENERGY Green Logic,LLC Approved Adam Suprenant 425 South Harbor Road Southold,NY 11971 Total System Size 4.578kW Array Size:4 578kW 1 string of 7 and 1 string of 7 on SB- 5000TL Azimuth 161' Pitch 39° _ �—_Material List _._._ i _-1Rail-Material List_ Monitoring System: -- -- -- - -- SunPower 44 S - - --�---� -- - - Panel/Array Specifications: S5$ClamP i I _. ____ I Panel:SPR-E20-327 Racking:SunPower Invisimount --- - ---- Panel:61 39"X 41.18" ( Array 20'10 7/8"X 11'11 3/" -- -- ----------_ - - Surface.24'10"X 14 Magic# Invisimount - -.- Legend: 14 SunPower 327W Panels SunPower Invisimount Rad S5-S Clamp NC550S-1.5".032ga 15"O.C. i r�_._�___--- Standing Seam Roof _ I - Notes I T---- Number of Roof Layers:1 --- -_ Height above Roof Surface 4"Materials Used-Eco-Fasten,SunPower, SMA - _-_._.-_____'-_ f___ __ ______- _____ _--- ____- - - ____ ___._ Roof load of PV System 3.5psf -- Added R -_ ___ �l - I Engineer/Architect Seal: ®F NE►v PA 0 ' o r— ' saevv� / L r• A G6618`- �OFESSI0\4 Drawn By:MMB Drawing#5 of 5 Date 8/15/2016 1 REV A Drawing Scale:3/32"= 1.0' EXISTING SERVICE f 120/240, 1 PH, 3 200A KIS H I NEW EQUIPMENT - - --� I I I I MAIN 200A i BUS I PV--Sri- 1 A I A li� I I r e I I (11 • • . 2 i I I �e © e I 13 FE I I N INTEGRAL DC/AC I ® ® ® DISCONNECTING SWITCH � I I I I G� PV-SA-- 1 B I C E0 I GEC IL — .........I...... .. ._.�. .�.M. ....,.. .�.�. — .�._., f I 0 CU EXISTING AC PANEL PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Adam Suprenant <<- 425 South Harbor Road Southold, NY 11971 ELIMINATING THE COST OF ENERGY 1 ) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 2 Drawing No: SPRNT-3LD1 Revision: 1 Revised: 3/31/2016 EQUIPMENT&COMPONENT SCHEDULE CONDUCTOR SCHEDULE TAG DESCRIPTION SPECIFICATION TAG TYPE/CONDUIT AWG./EGC PV-SA-1A PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327, 1-STRING OF 7-MODULES A USE-2, PV-WIRE / PVC-40 10 / 6 PV-SA-1B PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327, 1-STRING OF 7-MODULES B THWN-2 / PVC-40 8 / 6 INV-1 INVERTER, DC/AC SMA INVERTER, MODEL: SB5000TL-US-22, 240V NOTES: BFB GRID-TIE, BACK-FED-BREAKER MATCH EXISTING PANEL BRAND, 2-POLE, 30A 1.)CONDUCTOR TYPES AND SIZES TO BE AD- JUSTED FOR TEMPERATURE, DISTANCE,AND BUNDLING. 2.) CONDUIT TO BE MINIMUM PVC SCHEDULE 40, OR ALTERNATE PER SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLA- TION METHODS TO COMPLY WITH NEC AND LO- CAL CODE REQUIREMENTS. ELECTRICAL LOAD SUMMARY DC CIRCUITS ELECTRICAL LOAD.SUMMARY OP. CURRENT OP. VOLTAGE MAX.VOLTS S.S.C. AC CIRCUITS TAG @STC @STC @ T-MIN @STC VOLTAGE MAX.AC MAX. DC TAG POWER RANGE CURRENT CURRENT PV-SA-1A 5.98 A DC 315 V DC 510 V DC 6.46 A DC PV-SA-1B 5.98 A DC 315 V DC 510 V DC 6.46 A DC INV-1 5000 WATTS 211-284 VAC 22 A AC 30 A DC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Adam Suprenant fe, 425 South Harbor Road g g= T, Southold, NY 11971 umm' AT€! THE COST OF ENERGY 1 ) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 2 Drawing No: SPRNT-3LD1 Revision: 1 Revised: 3/31/2016 �91(j N ROW E R 00/327 SOLAR PANEL 20% EFFICIENCY ®®�� SunPower E20 panels are the highest efficiency panels on the market today, SERIES providing more power in the some amount of space MAXIMUM SYSTEM OUTPUT Comprehensive inverter compatibility ensures that customers can pair the highest- efficiency panels with the highest-efficiency inverters, maximizing system output REDUCED INSTALLATION COST More power per panel means fewer panels per install. This saves both time and money. RELIABLE AND ROBUST DESIGN SunPower's unique Maxeon'cell THE WORLD'S STANDARD FOR SOLART"' technology and advanced module erM T SunPowE20 Solar Panels provide today's highest efficiency and design ensure industry-leading reliability performance Powered by SunPower Maxeon'cell technology, the E20 series provides panel conversion efficiencies of up to 20 1% The E20's low voltage temperature coefficient, anti-reflective glass and exceptional low-light performance attributes provide outstanding energy delivery per peak power watt SUNPOWER'S HIGH EFFICIENCY ADVANTAGE 20% 0 01 t s. ® THIN FILM CONVENTIONAL ,° Eg MAXEONTM CELL SERIES SERIES SERIES TECHNOLOGY Patented all-back-contact solar cell, providing the industry's highest efficiency and reliability C U` us SUNPOWER E20/327 SOLAR PANEL MODEL: SPR-327NE-WHT-D ------------ ELECTRICAL DATA IN CURVE Measured at Standard Test Conditions(STC)irradiance of 1000W/m°,AM 1 5,and cell temperature 250 C 7 Peak Power(+5/-3%) - - Pmax 327 W -1ocow/rn>at5®°C_ --- —- -- 6 -1000 W/m2 - Cell Efficiency 11 225% 5 - Panel Efficiency n 201 % a 809iiiii I_ r Rated Voltage Vmpp 54 7V 3 Rated Current -- Impp - -- 5 98 A V 2 500 W/M2 ---------------- ------------- Open Circuit Voltage Voc 64 9 V 1 200 W/mO � \ Short Circuit Current Isc 6 46 A 0 Maximum System Voltage UL 600 V 0 10 20 30 40 50 60 70 — --- ------- Temperature Coefficients Power(P) -0 38%/K Voltage M Current/voltage characteristics with dependence on Irradiance and module temperature Voltage(Voc) -176 6mV/K ---- — -- Current(Isc) 3 5mA/K — -- -- — — TESTED OPERATING CONDITIONS NOCT 45`C+/-2°C Series Fuse Rating 20A Temperature -400 F to+1850 F(-400 C to+850 C) Grounding - Positive grounding not required Max load 113 psf 550 kg/m2(5400 Pa),front(e.g snow) w/specified mounting configurations MECHANICAL DATA 50 psf 245 kg/M2(2400 Pa)front and back —_ (e.g wind) Solar Cells 96 SunPower Maxeon'cells - Front Glass High-transmission tempered glass with Impact Resistance Hail:,(25 mm)at 51 mph(23 m/s) anti-reflective(AR)coating — ----------- - Junction Box IP-65 rated with 3 bypass diodes —� WARRANTIES AND CERTIFICATIONS Dimensions:32 x 155 x 128 mm Output Cables 1000 mm cables/Multi-Contact(MC4)connectors Warranties 25-year limited power warranty Frame Anodized aluminum alloy type 6063 (black) 10-year limited product warranty Weight 41.0 lbs(18.6 kg) Certifications Tested to UL 1703 Class C Fire Rating -- -- -- -- - -------- DIMENSIONS — 2X 11 Of 43] MM (A)-MOUNTING HOLES (B)-GROUNDING HOLES 30[118] ---�{ 2X577[2270] 180[7 071 (IN) 12X066[261 10X042[17] 322[12 69] 4X2308[909] Indi f o o� BOTH o I ^N o ENDS N N o N N 1559[61 391 46[181] (A) 915[3602] 1200[4724] 12(47] 1535[6045] Please read safety and installation instructions before using this product, visit sunpowercorp.com for more details. ©2011 SunPower Corporation SUNPOWER,the SunPower Logo,and THE WORLD'S STANDARD FOR SOLAR,and MAXEON are trademarks or registered trademarks sun Powe rc o r p.co m of SunPower Corporation In the US and other countries as well All RightsReserved Speohcations mcluded In this datosheet are subject to change without notice Document#001-65484 RevB/LTR—EN CS 11 316 �,. SUNNY BOY 300OT! -US / 3800TL-US /40001 L-US / 500OTL-US / 600OTL-US / 7000 T L-US / 770OTL-US __ ,r l �} ra THE W'ORLD'S ONLY SECURE POWER SUPPLY ------------ Certified Innovative Powerful Flexible •UL 1741 and 1699B compliant •Secure Power Supply provides •97.6%maximum efficiency •Two MPP trackers provide •Integrated AFCI meets the require- daytime power during grid outages •Wide input voltage range numerous design options ments of NEC 2011 690.11 •Shade management with OptTrac •Extended operating Global Peak MPP tracking temperature range SUNNY BOY 3000TL-US / 380OTL-US /4000TL-US / 5000TL-US / 6000TL-US / 7000TL-US / 770OTL-US Setting new heights in residential inverter performance The Sunny Boy 3000TL-US/3800TL-US/4000TL-US/5000TL-US/6000TL-US/7000TL-US/7700TL-US represents the next step in performance for UL certified inverters.Its transformerless design means high efficiency and reduced weight Maximum power production is derived from wide input voltage and operating temperature ranges. Multiple MPP trackers and OptiTracTM Global Peak mitigate the effect of shade and allow for installation at challenging sites.The unique Secure Power �PpEttJ 1h/FG�9 Supply feature provides daytime power in the event of a grid outage. High performance, flexible design and innovative r * features make the Sunny Boy TL-US series the first choice among solar professionals. & A Q� 0 1%IMP 0 Technical data Sunny Boy 3000TL-US Sunny Boy 380OTL-US Sunny Boy 4000TL-US 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 240 V AC Input(DC) Max usable DC power(@ cos q)=1) 3200 W 4200 W 4200 W Max DC voltage - 600 V 600 V 600 V Rated MPPT voltage range 175-480 V 175-480 V 175-480 V MPPT operating voltage range 125-500 V 125-500 V 125-500 V Min DC voltage/start voltage 125 V/150 V 125 V/150 V 125 V/150 V Max operating input current/per MPP tracker 18 A/15 A 24 A/15 A 24 A/15 A Number of MPP trackers/strings per MPP tracker 2/2 Output(AC) AC nominal power 3000 W 3330 W 3840 W 4000 W Max AC apparent power _ 3000 VA 3330 VA 3840 VA 4000 VA Nominal AC voltage/adjustable 208 V/• 240 V/• 208 V/• 240 V/• 208 V/• 240 V/• AC voltage range 183-229 V 211 -264 V 183-229 V 211 -264 V 183-229V 211 -264 V AC grid frequency,range 60 Hz/59 3-60 5 Hz 60 Hz/59 3-60 5 Hz 60 Hz/59 3-60 5 Hz Max output current 15 A 16 A 20A Power factor(cos(p) 1 1 1 Output phases/line connections 1/2 1/2 1/2 Harmonics <4% <4% <4% Efficiency Max efficiency 972% 976% 97.2% 97.5% 972% 975% CEC efficiency 965% 965% 965% 970% 965% 970% Protection devices DC disconnection device • DC reverse-polarity protection • Ground fault monitoring/Grid monitoring 0/0 AC short circuit protection • All-pole sensitive residual current monitoring unit • Arc fault circuit interrupter(AFCI)compliant to UL 16998 • Protection class/overvoltage category I/IV General data Dimensions(W/H/D)in mm(in) 490/519/185 (19 3/20 5/7 3) DC Disconnect dimensions(W/H/D)in mm(in) _ 187/297/190 (74/11 7/75) Packing dimensions(W/H/D)in mm(in) 617/597/266 (243/235/105) DC Disconnect packing dimensions(W/H/D)in mm(in) 370/240/280 (14.6/9 4/11 0) Weight/DC Disconnect weight 24 kg (53 Ib)/3 5 kg (8 Ib) Packing weight/DC Disconnect packing weight 27 kg (60 Ib)/3 5 kg (8 Ib) Operating temperature range -40°C. +60°C (-40°F +140°F) Noise emission(typical) 5 25 dB(A) <25 dB(A) <25 dB(A) Internal consumption at night <1 W <1 W <1 W Topology Transformerless Transformerless Transformerless Cooling Convection Convection Convection Electronics protection rating NEMA 31? NEMA 3R NEMA 3R Features Secure Power Supply • • • Display graphic • • • Interfaces RS485/Speedwire/Webconnect _ 0/0 0/0 0/0 Warranty 10/15/20 years •/O/O •/O/O 0/0/0 Certificates and permits(more available on request) UL 1741,UL 1998,UL 1699B,IEEE]547,FCC Part 15(Class A&B),CAN/CSA C22 2 107 1-1 NOTE US inverters ship with gray lids Type designation SB 3000TL-US_22 SB 380OTL-US-22 SB 4000TL-US-22 ------------------------------------------------------------------------ -----------------------i Efficiency curve SUNNY BOY 5000TL--US-22 240Vac F-------------------- Accessories 98-"-'--`- ---'---- ' --- ------ - ••`••_•...... - -- --- -_- WDM US10M-485CB-US-10 f ; 96 -- ............. i Speedwve/VJebconnect -i interface D interface 94-- --�- ---- ------------- ------ - ---�-- ---- i 92- --- —-- --- ( 98 � Fan 61forSB 3000/3800/ tE 90 w ) ••• Ha NN�175 VI � 96 _ U S-22 FANKIT02-10 88 Era IV,�=400 VI r 7s 480 86 1----- - - Ela IVB.=480 VI - V„„M -- 00 02 04 06 08 10 •Standard feature 0 Optional feature —Not available -----------------------------------------------Output power--Rated power Data at nominal conditions i Sunny Boy 5000TL-US Sunny Boy 6000TL-US Sunny Boy 7000TL-US Sunny Boy 770OTL-US 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 240 V AC 5300 W 6300 W 7300 W 8000 W 600 V 600 V 600 V 600 V 175-480 V 210-480 V 245:-480 V 270-480 V 125-500 V 125-500 V 125-500 V 125-500 V 125V/150V 125V/150V 125V/150V 125V/150V 30 A/15A 30 A/15A 30A/18A 30A/18A 2/2 4550 W 5000 W 5200 W 6000 W 6000 W 7000 W 6650W 7680 W 4550 VA 5000 VA 5200 VA 6000 VA 6000 VA 7000 VA 6650 VA 7680 VA 208 V/• 240 V/• 208 V/• 240 V/• 208 V/0 240 V/• 208V/0 240V/0 183-229 V 211 -264 V 183-229V 211 -264 V 183-229 V 211 -264 V 183-229 V 211 -264 V 60 Hz/59 3-60 5 Hz 60 Hz/59 3-60.5 Hz 60 Hz/59 3-60 5 Hz - 60 Hz/59 3-60 5 Hz 22A 25 A 29 2 A 32A 1 1 1 1 1/2 1/2 1/2 1/2 <4% <4% <4% <,4 972% 97.6% 970% 97.4% 96.8% 968% 968% 973% 965% 970% 965% 97.0% 965% 965% 965% 965% • • • I/IV 490/519/185 (19.3/205/73) 187/297/190 (74/11 7/75) 617/597/266 (243/235/105) 370/240/280 (146/94/110) 24 kg (53 Ib)/3 5 kg (8 Ib) 27 kg (60 Ib)/3 5 kg (8 Ib) -40°C +60°C (-40 IF +140°F) <29 dB(A) <29 dB(A) <29 dB(A) <29 dB(A) <1 W <1 W <1 W <1 W Transformerless Transformerless Transformerless Transformerless Convection Fan Fan Fan NEMA 3R NEMA 3R NEMA 3R NEMA 31Z 0/0 0/0 0/0 0/0 0/0/0 0/0/0 0/0/0 9/0/0 UL 1741,UL 1998,UL 16998,IEEE1547,FCC Part 15(Class A 8r B),CAN/CSA C22 2 107 1-1 SB 5000TL-US-22 SB 6000TL-US-22 SB 7000TL-US-22 SB 770OTL-US-22 rimz ■■ More efficient Shade management Easier _ILA17 �!E� Ei 1b Secure Power Supply Broad temperature range Flexible communications A NEW GENERATION OF INNOVATION THE SUNNY BOY TL-US RESIDENTIAL SERIES HAS YET AGAIN REDEFINED THE CATEGORY. Transformerless design in all types of climates and for longer periods of Leading monitoring time than with most traditional string inverters. and control solutions The Sunny Boy 3000TL-US / 380OTL-US - / 4000TL-US / 5000TL-US / 6000TL-US / Secure Power Supply The new TL-US residential line features more =e 7000TL-US/770OTL-US are transformerless than high performance and a large graphic inverters, which means owners and Installers One of many unique features of the TL-US display. The monitoring and control options " benefit from high efficiency and lower weight. residential series is Its innovative Secure provide users with an outstanding degree of s A wide input voltage range also means the Power Supply. With most grid-tied inverters, flexibility. Multiple communication options E Inverters will produce high amounts of power when the grid goes down, so does the solar- allow for a highly controllable inverter 4 under a number of conditions. powered home SMA's solution provides and one that can be monitored on Sunny 9 daytime energy to a dedicated power outlet Portal from anywhere on the planet via an a Additionally, transformerless inverters have during prolonged grid outages, providing Internet connection. Whether communicating a o been shown to be among the safest string homeowners with access to power as long as through R5485, or SMAS new plug-and-play m r inverters on the market.An industry first,the TL- the sun shines WebConnect, installers can find an optimal r US series has been tested to UL 1741 and UL solution to their monitoring needs. o 1699B and is in compliance with the arc fault Simple installation ; E requirements of NEC 2011. Wide Power Class Range -IncrAs a transformerless inverter, the TL-US -5- increased eased energy production residential series Is lighter in weight than Whether you're looking for a model to a its transformer-based counterparts, making maximize a 100 A service panel or trying OptiTracT'A Global Peak, SMA's shade- it easier to lift and transport. A new wall to meet the needs of a larger residential PV E tolerant MPP tracking algorithm, quickly mounting plate features anti-theft security and system, the Sunny Boy TL-US with Secure o adjusts to changes in solar irradiation,which makes hanging the inverter quick and easy.A Power Supply has you covered. Its wide d mitigates the effects of shade and results in simplified DC wiring concept allows the DC range of power classes—from 3 to 7.7 kW— higher total power output.And,with two MPP disconnect to be used as a wire raceway, offers customers the right size for virtually any a trackers, the TL-US series can ably handle saving labor and materials. residential application.The TL-US series is not 9 0 complex roofs with multiple orientations or only the smartest inverter on the planet,it's also string lengths. The 380OTL-US and 770OTL-US models allow the most flexible. Installers to maximize system size and energy y An extended operating temperature range of production for customers with 100 A and 200 s -40 °F to+140 °F ensures power is produced A service panels. o Toll Free +1 888 4 SMA USA www.SMA-America.com SMA America, LLC T un nxswtam Simple and Fast Installation _-- Integrated module-to-rail grounding Pre-assembled mid and end clamps Levitating mid clamp for easy placement Mid clamp width facilitates consistent,even module spacing Simple,pre-drilled rail splice UL 2703 Listed integrated grounding Flexible Design ` "° _ Addresses nearly all sloped residential roofsf,Pr Design in landscape and portrait ' ? Rails enable easy obstacle management - Js Customer-Preferred Aesthetics #1 module and#1 mounting aesthetics Best-in-class system aesthetics Elegant Simplicity Premium,low-profile design Black anodized components SunPower° InvisiMountTm is a SunPower-designed Hidden mid clamps and end clamps rail-based mounting system.The InvisiMount system and capped,flush rails addresses residential sloped roofs and combines faster Part of Superior System installation time, design flexibility, and superior aesthetics. Built for use with SunPower DC and AC modules The InvisiMount product was specifically envisioned and Best-in-class system reliability and aesthetics Combine with SunPower modules and engineered to pair with SunPower modules The resulting monitoring app system-level approach will amplify the aesthetic and installation benefits for both homeowners and installers. /7 lllllJl i Q sunpower.conn �{' `` i� .bird•_ -- --- -..��.+dre:._t - --_ -- �� �y+�.�, ION I Module*/Mid Clamp and Rail Module*/End Clamp and Rail Mid Clamp End Clamp Rall&Rail Splice Ground Lug Assembly End Cap Temperature -40°C to 90°C(-40°F to 194°F) Component Material Weight Max Load(LRFD) 3000 Pa uplift 6000 Pa upliftdownrce Mid Clamp Black oxide stainless steel AISI 304 63 g(2 2 oz) End Clamp Black anodized aluminum alloy 6063-T6 110 g(3 88 oz) Rad Black anodized aluminum alloy 6005-T6 830 g/m(9 oz/ft) Mammin Wd.maltiCt ° Rail Splice Aluminum alloy 6005-TS 830 g/m(9 oz/ft) 25-year product warranty Ground Lug 304 stainless Warranties Assembly (A2-70 bolt,tin-plated copper lug) 106 5 g/m(3 75 oz) 5 year finish warranty End Cap Black acetal(POM)copolymer 10 4 g(0 37 oz) • UL 2703 Listed Certifications °o o M-6mm Hmn jajm%ppmmid by Class A Fire Rated M041J *NW Down Tw Composition Shingle Rafter Attachment Application Composition Shingle Roof Decking Attachment o o d e SHadmim WiffaMa Curved and Flat Tile Roof Attachment Universal Interface for Other Roof Attachments Refer to roof attachment hardware manufacturer's documentation *Module frame that is compatible with the Invisilvount system required for hardware interoperability ©2015 SunPower Corporation All Rights Reserved SUNPOWER,the SUNPOWER logo,and INVISI MOUNT are trademarks or registered trademarks of Sun Power Corporation All other trademarks are the property of their respective owners Sunpower com Specifications included in this datasheet are subject to change without notice Document#509506 RevC 1