Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
40812-Z
SUFfDI,�c Town of Southold 11/28/2016 P.O.Box 1179 53095 Main Rd y,�0 p�+'� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38673 Date: 11/28/2016 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1905 Bay Shore Rd, Greenport SCTM#: 473889 Sec/Block/Lot: 53.4-9 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/27/2016 pursuant to which Building Permit No. 40812 dated 6/30/2016 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Zuar, Gary&Kathleen of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40812 11-09-2016 PLUMBERS CERTIFICATION DATED uthorized Signature o�gUF ar t,��o TOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40812 Date: 6/30/2016 Permission is hereby granted to: Zuar, Gary & Kathleen 28 Willets Ln Plandome, NY 11030 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 1905 Bay Shore Rd, Greenport SCTM # 473889 Sec/Block/Lot# 53.4-9 Pursuant to application dated 6/27/2016 and approved by the Building Inspector. To expire on 12/30/2017. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 uildi spector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. 013'1 Co New Construction: Old or Pre-existing Building: x (check one) Location of Property: 1905 Bay Shore Road Greenport House No. Street Hamlet Owner or Owners of Property: Gary&Kathleen Zuar Suffolk County Tax Map No 1000,Section 53 Block 4 Lot 9 Subdivision 1 Filed Map. Lot: Permit No. L4 0� I Date of Permit. Applicant: GreenLogic LLC Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: x (check one) Fee Submitted: $ 50.00 pplicant Signature pF S0�/Ty®� Town Hall Annex Telephone(631)765-1802 54375 Main Road CA Fax(631)765-9502 P.O.Box 1179 ® �Q roger.riche rt(@-town.southoId.ny.us Southold,NY 11971-0959 Q lyC®UNT�,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Zuar Address: 1905 Bay Shore Road City: Greenport St: New York Zip: 11944 Building Permit#: 40812 Section: 53 Block- 4 Lot: 9 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Green Logic License No: 43858-ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Surrey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 1 Twist Lock Exit Fixtures TVSS Other Equipment: 5.886KW Roof Mounted Photovoltaic System to Include; 18- SP 327W Panels, 1- SB 6000 Inverter. Notes: Inspector Signature: Date: November 9, 2016 0-81-Cert Electrical Compliance Form.xls pf SOUjy�lo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) M ELECTRICAL (FINAL) REMARKS: Fe DATE f INSPECTORS Pacifico Engineering PC _ _ Engineering Consulting 700 Lakeland Ave, Suite 2B (C _ Ph: 631-988-0000 Bohemia, NY 11716 .: P Fax: 631-382-8236 www.pacificoengineering.com I; CG c solar@pacificoengineering.com October 26, 2016 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Gary and Kathleen Zuar Section: 53 1905 Bayshore Road Block: 4 Greenport, NY 11944 Lot: 9 1 have reviewed the solar energy system installation at the subject address on October 26, 2016. The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2010 NYS Building Code, and ASCE7-05. To my best belief and knowledge, the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice, with the view to the safeguarding of life, health, property and public welfare. Regards, Ralph Pacifico, PE Professional Engineer �pF �1E�li ��P� �QH PAy0'A o [EUEUVE cc D NOV 1 5 2016 nn06618 RalpR iP 7f� ngineer BU"ING DEPT. NY 066 04744306 1 TOWN OF SOUMOLD FIELD n'SI'E=C}N REVOR'T DATE COr i'S5 ' FOUNDA'�ION(1ST) ci A OUNA�TION(2m) AE:�l ROUGH FRAN2NQ& PLUMBTIiG r . . H IMULATZON PEA N,Y. STATE ENERGY CODE FINAL low �-oo ' In r � • red TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX: (631)765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined 20—P Storm-Water Assessment Form 2Contact: Approved Jb ,20& Mail to: 'GreenLogic LLC Disapproved a/c 425 CR 39A,Ste 202,Southampton,NY Phone: 631-771-5152 Expiration ,20 no) 115 v Buil in nspector D JON 2 7 2016 PLICATION FOR BUILDING PERMIT Date �,dl P ,20J-Jro D� MI)INd�Dm. INSTRUCTIONS a.T I dpplicoation�3U� STO e�completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall.be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations;and to admit authorized inspectors on premises and in building for necessary inspections. ( 'gnature of applicant or name,if a corporation) 425 CR 39A,Ste,202 Southampton,NY 11968 (Mailing address of applicant) State whether applicant is'owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Contractor Name of owner of premises Gary&Kathleen Zuar (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. 40777-H Plumbers License No. Electricians License No. 43858-ME Other Trade's Licenso No. 1. Location of land on which proposed work will be done: 1905 Bay Shore Road Greenport House Number Street Hamlet County Tax Map No. 1000 Section 53 -Block , 4. Lot 9 Subdivision ..-Filed--MapNo: Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Single Family Dwelling b. Intended use and occupancy Single Family Dwelling 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work Roof mounted solar panels (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures,if any: Front Rear Depth Height Number of Stories - ' ra j I t Dimensions of same structure with alterations or additions: Front . Rear �.; Depth Height Number o orieg ��.:a , ;1 fi A n r v ti, riv4 8. .Dimensions of entire new construction: Front Rear Depth Height Number of Stories m "'' 'n rq 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO e� 13. Will lot be re-graded?YES NO Will excess fill be removed from premises?YES NOy/ Gary&Kathleen 1905 Bay Shore Rd 14.Names of Owner of remises 7„ar Address Green ort NY Phone No. 516-627-7780 Name of Architect f,'i♦^�(� I:lIG;�AQQI"ir14 P° Address-th U' Phone No (.31 -9S$-WM Name of Contractor Green Logic LLC Address 425 CR-39A Phone No. 631-771-5152 Southampton,NY 11968 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES ✓ NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES �7 NO * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property? * YES NO ✓ * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF_� Nesim Albukrek being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S')HC'is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief,and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this " _day of ,RJ/LL 20Jj(m 0f---�> AA Notary Public SAMANTHA CORBE17 V Signature of Applicant Notary Public,State of New York Reg.No.01 C06335944 Qualified in Suffolk County Commission Expires January 19,2020 Scott A. Russell STORMWATIER, SUPERVISOR MA.,NAG]EMIENT SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEWYORK 11971 Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) -------- - - DOES THIS PROJECT IM79LVE AN7 'Of THE FOLLO'WING' {CHECK ALL TIJAT APPLY] ii !I ye!, No A. Clearing, grubbing, grading or stripping of land which affects more ii than 5,000 square feet Of ground surface. B. Excavation or filling involving more than 200 cubic yards of material 4P within any parcel or any contiguous area. E] C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. Q€` E] D. Site preparation within 100 feet of wetlands, beach, bluff or coastal it erosion hazard area. [I El E. Site preparation within the one-hundred-year f loodplain as depicted on FIRM Map of any watercourse. it []E] F. Installation of new or resurfaced impervious surfaces of 1,000 square is feet or more, unless prior approval of a Stormwater Management 1! Control Plan was received by the Town and the proposal includes it E in-kind replacement of impervious surfaces. ......... If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature,Contact Information,Date & County Tax Map Number! Chapter 236 does not apply to your project- If you answered YES to one or more of the above,please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department withyourBuilding Permit Application. ifT T S.C.T.1K 1000 Date: PPLICA,.N,r (Properif%(Nviier,De�stgn Profe_�sicsliini,Agent,Cotitractoi,Othei) District NX ME GreenLogic LLC(Nesim Albukrek) i 53 4 9sectioll, -9—lack Lot Wah-so— AA 4fZ_'Z FOR BUILDING DEPRTNIL NTUSE ONLY' 'L'�-�771-5152 C-Ontacl ffiformallon Reviewed By: --- - - - - - - - - - - - - - - - —! — — — — — — — it Date: il Property Address 1 Location of Construction Work: — — — — — — — — — — — — — — — — — Approved for processing Building Permit. it 1905 Bay Shore Rd- Greenport- NY 119444 — Stormwater Management Conti-of Plan Not Required. C9 I — — — — — — — — — — — — - - — — I Stormxvater Management Control Plan is Required. (Forward to Engineering Department for Review.) 1 f 7 spry° Town Hall Annex i 54375 Main Road Telephone{6310 7g65p1g802 j P.O.Box 1179 G roger.richert Q fOWf s'o6utgold,ny.us Southold,NY 1197I-0959 i • i- BUII,DING DEPARTMENT i TOWN OF SOUTHOLD i APPLICATION FOR ELECTRICAL INSPECTION • i REQUESTED BY: Samantha Corbett Date: N ompany Name: GreenLogic LLC j Company Robert Skypala ? I License No.: 43858-ME j Address: 425 Coun Road 39A, Southampton; NY 11968 Phone No.: 631-771-5152 JOBSITE INFORMATION: (*Indicates required information) *Name: Gary&Kathleen Zuar C *Address: 1905 Bay Shore Rd, Greenport, NY 11944 � *Cross Street: Kerwin Blvd *Phone No.: 516-627-7780 Permit No.: 40RI I Tax-Map District: 1000 Section: 54 Block: 4 Loot: 9 ; *BRIEF DESCRIPTION OF WORK(Please Print Clearly) Roof mounted solar electric system (Please Circle All That Apply) Is job ready for inspection: YES NO Rough In Fina! *Do-you need a Temp Ceffi icate: <2E 1.NO Temp Information(if needed) i 'Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION o 8241equest for Inspection Form ` �� I REENL GIC° ENERGY azoHlaos ao xmos •tea OmwMs June 3, 2016 SO? L Z Nw Town of Southold Building Department a n a Town Hall 53095 Route 25 Southold, NY 11971 Dear Building Inspector: Please find attached a building permit application on behalf of Gary& Kathleen Zuar who has engaged us to install a ground-mounted solar photovoltaic (PV) electric system for their home located at 1905 Bay Shore Rd, Greenport, NY. In connection with this application, please find attached: • Building Permit application • A Storm Water Assessment Run-off Form • Certificate of Occupancy Application • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports (2 originals and 2 copies) • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels • 2 Spec. sheets of the inverter • 2 Spec. sheets for Racking System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200 ($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, Sa anA�aCorb!tt_ Account Manager Samantha.Corbett@Greenlogic.com 631-771-5152 ext. 107 GREENLOGIC LLC o www.GreenLogic.corn Tel: 877 7714330 Fax. 877.771 4320 SOUTHAMPTON ROSLYN HEIGHTS 425 County Rd 39A 200 S Service Rd ,#108 Southampton, NY 11968 Rosyln Heights, NY 11577 GREELOGIC® ENERGY November 7, 2016 The Town of Southold Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Re: Building Permit No. 40812 Gary & Kathy Zuar 1905 Bay shore Rd, Greenport 53-4-9 To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the above referenced solar electric system which we installed. Please arrange to send them the Certificate of Occupancy and close out the building permit. Please let me know if you have any questions regarding the installation. Sincerely, C' Va�ma�ntha Corbett Account Manager Samantha.Corbett@Greenlogic.com 631-771-5152 Ext. 107 �C ENT= D D NOV 1 5 2016 13UMDINO DWT- TOWN OF SOUT110LO GREENLOGIC LLC o www.Green Logic.com Tel 877.771.4330 Fax: 877 771.4320 SOUTHAMPTON ROSLYN HEIGHTS 425 County Rd.39A 200 S Service Rd ,#108 Southampton, NY 11968 Rosyln Heights, NY 11577 ReceiptCopy Page 3 of 3 SUFFOLK COUNTY DEPT OF LABOR, LICENSING= &. CONSUMER AFFAIRS PAYMENT RECEIPT RECEIPT NO. 314485 GREENLOGIC LLC 425 COUNTY ROAD 39A (SUITE 202) SOUTHAMPTON NY 11968 Recd From: DIB/A: Date: M CLEJAN GREENLOGIC LLC 0410612016 Payment Type: No: Drawn On: CHECK 12357 SUFFOLK COUNTY NATIONAL BANK Category Service Fee Violation Slip No Remarks 5-H.I. Contractor C-Lic. Renew. $400.00 n SUFFOLK COUNTY DEPT.OF LABOR, LICENSING&CONSUMER AFFAIRS ! . , HOME IMPROVEMENT ;} CONTRACTOR NAM LICENSE MARC A CLEJAN This certifies that the Gf bearer is duly REENLOGiC LLC licensed by the County of Suffolk l xensa Hunte oak snub 40227-H M25/2006 E*"A"rsansr_ 05/0112018 REC'D BY: L-wuriberr+ c�ey►s�ratwrtt�: CL _ _ .. .- ._ _... ._._. °� 0227. . . • __ -�. .. _ _.___ OTAL: Remarks: 400°00 ATTENTION HOME IMPROVEMENT CONTRACTORS Suffolk County Code Chapter 563-17 (D) states: All advertising for Home Improvement contracting shall contain the number of the Home Improvement license. Customer copy http://suffolk-ca,'receipteopy.aspx?ID=314485 =1/6/2016 CERTIFICATE OF LIABILITY INSURANCEDATE(MMIDD/YYYY) 01/25/2016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Brookhaven Agency,Inc. Brookhaven Agency,Inc. PHONE 631 941-4113 FAX 631 941-4405 128 Old Town Road Suite C EMAIL , brookhaven.agency@verizon.net PO BOX 850 PRODUCER East Setauket NY 11733 INSURERS AFFORDING COVERAGE NAIC# INSURED INSURERA: HDI-Gerling America Insurance Co. Greenlogic,LLC INSURER B: Merchants Preferred Insurance Co. 425 County Road 39A,Suite 202 INSURER C: First Rehab Life Insurance Co. Southampton,NY 11968 . INSURER D: Endurance American Insurance Company INSURER E: AGCS Marine Insurance Company INSURER F: National Liability&Fire Insurance Co. COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXPIm LIMITS GENERAL LIABILITY EACH OCCURRENCE $1,000,000 A X COMMERCIAL GENERAL LIABILITY X X EGGCC000076916 01/31!16 01/31/17 DAMAGE TO RENTED $100,000 CLAIMS-MADE Fx_]OCCUR MED EXP(Any oneperson) $5,000 X XCU PERSONAL&ADV INJURY $1,000,000 X Contractual Liab GENERAL AGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER. PRODUCTS-COMP/OP AGG $2,000,000 POLICY FX I PRO LOC $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT B X, ANYAUTO CAP1043565 8111/15 8/11116 (Ea accident) $1,000,000 BODILY INJURY(Per person) $ ALL OWNED AUTOS BODILY INJURY(Per accident) $ SCHEDULED AUTOS PROPERTY DAMAGE $ X HIRED AUTOS (Per accident) X NON-OWNED AUTOS $ X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $1,000,000 D EXCESS LIAB CLAIMS-MADE X X EXC10006421400 01/31/15 01/31/16 AGGREGATE $1,000,000 DEDUCTIBLE $ RETENTION $ WORKERS COMPENSATION X WC STATU-1 FIR OT AND EMPLOYERS'LIABILITY F ANY PROPRIETOR/PARTNER/EXECUTIV� N/A V9WC653352 6115/15 6/15/16 E L EACH ACCIDENT $1,000,000 OFFICERIMEMBER EXCLUDED? (Mandatary in NH) E L DISEASE-EA EMPLOYEE $1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $1,000,000 C NYS Disability D251202 4111/15 4/11/16 Statutory Limits E Installation Floater/Pro a MX183958282 4/15/15 4/15116 $1,000,000 $1,000 Ded DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(Attach ACORD 101,Additional Remarks Schedule,if more space is required) CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT, ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2009 ACORD CORPORATION. All rights reserved. ACORD 25(2009109) The ACORD name and logo are registered marks of ACORD STATE OF NEW YORK WORKERS'COMPENSATION BOARD CERTIFICATE OF NYS WORKERS' COMPENSATION INSURANCE COVERAGE Ia.Legal Name&Address of Insured(Use street address only) lb.Business Telephone Number of Insured Greenlogic LLC 631-771-5152 425 County Rd 39A Ste 202 Ic.NYS Unemployment Insurance Employer Southampton NY 11968 Registration Number of Insured Id.Federal Employer Identification Number of Insured Work Location of Insured(Only required'coverage is or Social Security Number spec fcally limited to certain locations/it New York State,L&,a 203801194 Wrap--up Policy) 2.Name and Address of the Entity Requesting Proof of 3a. Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) National Liability&Fire Insurance Company Town Of Southold 3b.Policy Number of entity listed in box"la" Building Department V9WC794777 53095 Route 25 3c. Policy effective period Southold,NY 11971 06/15/16 to 06/15/2017 3d. The Proprietor,Partners or Executive Officers are included. (Only check box if all partners/oMcers included) X all excluded or certain partnerstofficers excluded. This certifies that the insurance carrier indicated above in box"3" insures the business referenced above in box "1a" for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"T'. The Insurance Carrier will also note the above certificate holder within 10 days IF a policy is canceled due to nonpayment ofpremiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices maybe sent by regular mail.) Otherwise,this Cert f cate Is valld for one year after this form is approved by floe insurance carrier or lts licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. Please Note:Upon the cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by:NICHOLAS ZULKOFSKE (Print n of authorized representative or licensed agent of insurance carrier) Approved by: Mpy 23 2016 (Date) Title: Authorized Agent Telephone Number of authorized representative or licensed agent of insurance carrier: 631-941-4113 Please Note.Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2(9-07) www.wcb.state.ny.us Workers' Compensation Law z \ 77�7ti • �-�;:��'i.n�+:. � .= ..'�:: v ,m.r .rf f. ,, :�4'� 5 �� . . :'.. :.1.4 fy�� '�wkr a �S _ i �?< :,f:.-: `�d,�,a A � '5 S pp t, ip. `s _i ,1YOffice Consumer a Affairs . Executive's r VETERANS MEMORIAL HIGHWAY HAUPPAUGE, NEWYORK 11788 $ i DATE ISSUED: 12/10/2007 No. 43858-ME Al SUFFOLK COUNTY Master Electric to certify that ROBERT h da • _ GREENLOGICLLC satisfactoryhaving given • of r a. is hereby licensed as MASTER ELECTRICIAN in accordance . i r twith and subject to the provisions of ►• ..' and regulations of Countythe of a of New York. n Additional BusinegesfSW. 1 I; NOT VALID WITHOUTDEPARTMENTAL SEALo \�!� ✓` AND N CURRENTI . CONSUMER AFFAIRS 11)CARD "dA' Director 1 s � f.f x ',F' ti`@•.:,.,�f � °v` 4 .:?!� ^�l�' ,�_R �"d[�.<=�^ ,�.^• s: r �.� �a a ��rfl� �^+�?, -�.• •� arm - � '�+5' .^.,�� Z� •�', *°',w-��;.r ,,' ..,i,;t .���C.- r�:�li,}j v�� � ':>r y �L� t ` �(,l�" `r., / � ° / ,;;; ,r . /,r "^ ,1. �. / `' �>, `... xl ,,'\�•� ^Fr It `yl»`�::%.�> fl i::��n,'if:F \1lI !I ti\ l:., F� �1. L� ��: Y` t .4` /� q��I -!f �� SURVEYED FOR: GARY & KATHLEEN ZUAR 4' PROPERTY LOCATED AT ARSHAMONAQUE LOT No. 31 & P/0 30 AS SHOWN ON AMENDED MAP "A" PECONIC BAY ESTATES ?69°06, FILED: MAY 19. 1933: FILE No. 1124 TOWN OF SOUTHOLD SUFFOLK COUNTY. NEW YORK S.C.T.M. # 1000-53-4-9 TOTAL LOT AREA 29.550 SF = 0.6784 ACRES UPLAND AREA = 16.464 SF. GF SCALE: 1"=40NOTE: THE WETLANDS AND/ORNEASCE OEM NITS OF RECORD GHT OF WAYS. r ® 36 5R201NF IF ANY. NOT SHOWN ARE NOT GUARANTEED. WETLAND FLAGS BY SHAWN BARRONy1Gh 6-11-2013 g�S\e FLOOD ZONE FROM FIRM 2013 FEMA MAP # 36103CO159WALL BEACH ® COMMUNITY T/O SOUTHOLD 360813 � CONC. 0.4'/N AREA RETAIN. v WALL ELEVATIONS = NAVD 1988 Q,O WALL 1 0.8'/N ,S ® Ov VE GREAT\ �d "b iP h� [•" FOUNDATION '�"�F FT- 90 10.1'/S CD c m S Off. �0 DcK x/ N o��c ��l a.s °0 10.5• FENCE a �° WETLANDS/ OO/ 09�1T� h ,9 m 1.2'/N RETAINING WALL tK s0 0� S FOUNDATION POLE 10.7•/N FOOTINGS 10.0'/S oV� �C, ale rs�2 ��0. 000jc / v0 � 1) AFO IPE OG 5r�oyoG SFS �' ��`� v��'�e SURVEYED BY: .7�' PAUL BARYLSKI LAND SURVEYING AD>> POLERey�Ge�. PATCHOGUE NY 11772 UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION �®�� 100� PHONE 631-294-6985 OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAY. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYORS INKED FAX 631-627-3166 OR EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. �� ® P A U L B A R Y L S K I a Y A H O O.C O M GUARANTEES OR CERTIFICATIONS INDICATED HEREON MALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED.AND ON HIS BEHALF TO THE TITLE COMPANY.GOVERNMENTAL AGENCY AND LENDING INSTITUTION JUNE 5. 2 13 LISTED HEREON.AND TO THE ASSIGNEES OF THE LENDING INSTITUTION 2-4-2014: PROP ADDITIONS GUARANTEES OR CERTIFICATIONS ARE NOT TRANSFERABLE TO ADDITIONAL INSTITUTIONS OR SUBSEQUENT OWNERS. 5-9-2014: PROP. GARAGE CHANGE 1271-4 10-15-2015: FOUNDATION LOCATION APPRO ED AS NOTE® ELECTRICAL INSPECTION REQUIRED DATE: 36 6.P.# FEE: SBY: 7- NOTIFY BUILDING DEPARTM AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE' 2. ROUGH - FRAMING & PLUMBING RETAIN STORM WATER RUNOFF 3. INSULATION PURSUANT TO CHAPTER 236 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. OF THE TOWN CODE. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF SO SOd�MI�l�EES.._� OCCUPANCY OR USE IS-UNLAWFUL cWITHOUT CERTIFICATE OFOCCUPANCY Pacifico Engineering PC __ Engineering Consulting C 700 Lakeland Ave, Suite 26 Ph: 631-988-0000 t Bohemia, NY 11716 — P Fax: 631-382-8236 www.pacificoengineering.com = atiIGC solar@pacificoengineering.com June 16, 2016 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Gary and Kathleen Zuar Section: 53 1905 Bayshore Road Block: 4 Greenport, NY 11944 Lot: 9 1 have reviewed the roofing structure at the subject address. The structure can support the additional weight of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2010 NYS Building Code, and ASCE7-05 when installed in accordance with the manufacturer's instructions. Roof Section A Mean roof height 19 ft Pitch 1/2 in/12 Roof rafter 1.75x14 LVL Rafter spacing 16 inch on center Reflected roof rafter span 18.2 ft Max allowable rafter span 33.0 ft The climactic and load information is below: CLIMACTIC ANDGround Wind Live load, Design load Load GEOGRAPHIC DESIGN Snow Load, regwremen capability, Exposure Speed,3 pnet30 per Safety CRITERIA Category Pg sec gust, ASCE 7, t psf psf factor mph psf Roof Section A C 20 120 36 69.3 194.0 2.8 Weight Distribution ®F NEgy array dead load 26.4 psf �cr PN PAcy� QA .0avq Ralph Pacifico, PE m I Professional Engineer FQ 06 61 b?, Ralph A'i® f I I neer NY 0661 -24G 744306 rGREENL061CO ENERGY GreenLogic,LLC Approved Zuar,Gary&Kathleen 1905 Bayshore Rd Greenport,NY 11944 Surface#A: Total System Size:5 886kW Array Size 5 886kW 2 strings of 6 and 1 string of 6 on SB6000TL Azimuth, 118° Pitch,2° Monitoring System:Zn Ix- Z 2 SunPower Panel/Array Specifications: Panel:SPR-E20-327 Racking:GenMount [XI x Panel:41 18"X 61.39" Array. 15'4.17"X 24'.384" Surface: 19'X 26'8" x x rF< Legend: ® 18 SunPower 327W Panel ® GenMount Ballast a2x14"Micro Lam Rafter 16"O C. Notes Number of Roof Layers-1 Height above Roof Surface:4" Materials Used:GenMount,SunPower, SMA Added Roof load of PV System 3.5psf Engineer/Architect Seal: 0�: NEW 1' CO Q�' Cp �O 066182 A%FESSX��P� Drawn By:ADL Drawing#1 of 4 Date: 1/27/2016 REV A Drawing Scale:3/16"=1.0' tm r'�_4110N ENERGY GreenLogic,LLC Approved Zuar,Gary&Kathleen 1905 Bayshore Rd Greenport,NY 11944 Surface#A: Total System Size:5.886kW Array Size:5.886kW 2 strings of 6 and 1 string of 6 on SB6000TL Azimuth: 118° Pitch:2° 1 Monitoring System 2 SunPower Panel/Array Specifications: Panel SPR-E20-327 1 Racking GenMount Panel 41.18"X 61 39" Array 15'417"X24'.384" Surface 19'X 26'8" 2 Legend: ® 18 SunPower 327W Panel ® GenMount Ballast 2x14"Micro Lam Rafter 16"O C Notes: Number of Roof Layers:1 3 Height above Roof Surface:4" Materials Used-GenMount,SunPower, SMA Added Roof load of PV System:3.5psf Engineer/Architect Seal: 3 0 SOF NEVv y. PAC/ 0 r— I W 066182 ARoFEss�o�'P Drawn By*ADL rawing#2 of 4 Date, 1/27/2016 1 REV.A Drawing Scale-3/16"=10' GREENL e Ell 1 SMA Inverter ENERGY Meter located located in GreenLogic,LLC Approved on H-framebasement Zuar,Gary&Kathleen 1905 Bayshore Rd. Greenport,NY 11944 Total System Size-5 886kW 2 strings of 6 and 1 string of 6 on SB6000TL Azimuth: 118° Pitch: ' Monitoring System: 2 SunPower Panel/Array Specifications: Panel:SPR-E20-327 Racking:GenMount OO Panel:41 18"X 61.39" Array. 15'4.17"X 24'.384" 1-114 Z Surface: 19'X 26'8" Legend: ® 18 SunPower 327W Panel ® GenMount a2x14"Micro Lam Rafter 16"O C. 0 :K O Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:GenMount,SunPower, SMA Added Roof load of PV System:3.5psf Engineer/Architect Seal: ®F NE1/Y /\g. QN PAC/p� 0 CO Qv � �0 16 SunPower 327W Panels n `•. �f cP3ss aP V NVQ '066182 AROFESS`��P� Drawn By.ADL Drawing#3 of 4 Date 1/27/2016 REV A Drawing Scale.3/32"=1.0' .0- "ZE/C aleos Bulmej(] V:A31:1 � 9WZ/LZ/L :91e(I J7 10 t7#BUIMeJ(l -1(]V:Ag umej(] ^aNO\SS3.zfo ,bsvggo O> rp vd Yl 3N P :lees j3qpLj3jv/jqGulr)u3 jsdg*C:WOISAS Ad JO PeOl 100�1 PGPPV vvqs aALIMHVJ3cf3.PDJ192J,.U@Isql-cc)3 'j9modunS'junoVyu9E):P@sn sieliamm j7:aoepnS joo�GAoqe WIGHW13ujnuLunjV,pajjmj,,u@Mj-a)3 L:sjaAe-1 joo�j jo jaqwnN Wki @SEEI,,laaj Wj,.ualsej-a)3 :sGION NQCSJ@PaMOD kil,.L)U-VT# '0*0,19L Ja)je�we-I ojolvq j7 Lxz ANaDSJE)PaXM kJ3,99tT# junoVMuaE) AN-ArSJ@PDJCD k]3,MT-VT# ajWHLsjspdu@aDLejq2j-a13 PuBd MLZE JBmOdunS 8L @MjauxuujnjVaatSu@jspj uaae Lolmj-mg :PUBBO-1 sww pals ssa p Ms.qL/Is .8.9Z X.6 L :aoejjnS slpa&lssoqTA ,,i79E',17Z X.L L V 9 L :AejjV XC19 X,,8L LV:18ued junoVMu90:6uiNoeH LZE-OZ3-UdS:19ued :suolje3l ed gpeft AejjV/Ieu fsnleu):Kwlm T isn P-.uaqm jamodunS WOJSAS BUIJOJIUON Z qol!d .9 -qlnwizV U00099S uo 9;0 Bulils L pue 9;0 SBUIAS Z M1999 9:9ZIS WaISAS lelo-L 1176L L),N'jjodu9E)jE) P:1 GJOqsABS 906 ueelqleN V fueE)'jenZ POAOJddV 377'DIB07u9OJD PD�A N 3 EXISTING SERVICE- 120/240, ERVICE- 120f24.0, 1 PN, 3r 200A -KWH -- - - _- - - NEW EQUIPMENT - - _ - - - - ---- I •. I I s MAI fel 200A , PV--SA-1 A BUS I A I 7m W -� 3 N A INV- 1 N • • • 2 r _ i I BFB - t V N • • • 2 1 ' INTEGRAL DC/AC I /m\ ® ® DISCONNECTING SWITCH GC PV®SA- 1 B I-GEC I SEC - � - EXISTING AC, PANEL. PROPOSED 3-LINE ELECTRICAL'DIAGRAM- Gary, & Kathleen Zuar _ REvisioNs 1905 Bayshore Rd :; �3 ; Greenport, -NY 11944 ELIMINATING' THE COST t F tNERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 2 Drawing No: ZUAR-3LD1 Revision: 1 Revised: 10/29/2015 EQUIPMENT&COMPONENT SCHEDULE CONDUCTOR SCHEDULE TAG DESCRIPTION SPECIFICATION TAG TYPE/CONDUIT AWG./EGC PV-SA-1A PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327, 1-STRINGS OF 6-MODULES A USE-2, PV-WIRE/PVC-40 10/6 PV-SA-1B PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327, 2-STRINGS OF 6-MODULES B THWN-2/PVC-40 8/6 INV-1 INVERTER, DC/AC SMA INVERTER, MODEL SB6000TL-US-22, 240V NOTES: BFB GRID-TIE, BACK-FED-BREAKER MATCH EXISTING PANEL BRAND,2-POLE,35A 1.)CONDUCTOR TYPES AND SIZES TO BE AD- JUSTED FOR TEMPERATURE, DISTANCE,AND BUNDLING. 2.)CONDUIT TO BE MINIMUM PVC SCHEDULE 40, OR ALTERNATE PER SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLA- TION METHODS TO COMPLY WITH NEC AND LO- CAL CODE REQUIREMENTS. ELECTRICAL LOAD SUMMARY DC CIRCUITS ELECTRICAL LOAD SUMMARY TAG OP. CURRENT OP.VOLTAGE MAX.VOLTS S.S.C. AC CIRCUITS @STC @STC @ T-MIN @STC VOLTAGE MAX.AC MAX. DC TAG POWER RANGE CURRENT CURRENT PV-SA-1A 5.98 A DC 270 V DC 437 V DC 6.46 A DC PV-SA-1B 11.96 A DC 270 V DC 437 V DC 12.92 ADC INV-1 6000 WATTS 211-284 VAC 1 25 A AC 30 A DC PROPOSED EQUIPMENT SPECIFICATIONS Gary & Kathleen Zuar REVISIONS shore Rd "' 1905 Ba Y e •fix �• e R Greenport, NY 11944 `'a. .•• m_ EB P ELIMINATINGE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 2 Drawing No: ZUAR-3LD1 Revision: 1 Revised: 10/29/2015 MU N. PO�V E R Wj0/327 SOLARRANEL 200/.'EFFICIENCY SunPorver E20 panels are the highest efficiency panels on the market too-ay, S E R 1 E S providing -pore oower in he same amaurt of space MAXIMUM SYSTEM OUTPUT Comprehensive inverter compatibility ensures that cusiorners can pair the night est efficiency panels with the highest-ef;rcency invertors, maximizing system oxput REDUCED INSTALLATION COST /',More po,,,.rer per panel means fewei,panels per install.This saves both time and money. RELIABLE AND ROBUST DESIGN SunPower's unique Maxeor-'``eell _ THE WORLD'S STANDARD FOR SOLARr'` technology and advanced module. SunPower_ E20 Saar Panels provide today's highest efficiency and design ensure industry-leading reliability performance Poweiea by SunPower Maxeon'cell technology, the E20 series provides panel conversior efficiencies of up to 20 1% Tne E20's low voltage lemperature coefficien, antrrelecti:`e glass and exceptional low-light ;uerforrnance attrib•ites provide ou stanaing erergy delivery per peak power watt SUNPOWER'S HIGH EFFICIENCY ADVANTAGE 15% 10% -- R',ago _ R', T,11N t lir4"t NVEi°1T;CNr1 r" CELL SUW S SE';I'_S SLRILS TECHNOLOGY Poterre :tt acc crsa t sohr gr=it prov:dma the i;dustry5 iigrhas` rfir.2 rc:y ane rehab t,}, - C&S N E 00/327 SULAR MNEL MODEL: SPR-327NE-WHT-D ELECTRICAL DATA- .1-V CURVE I000VV/&Y,IS 7 Peak Power(+5/-3%) Pmax- 327 W 6 1000W/W Cell Efficiency 225% 5 Panel Efficiency n 20.1 % a 4 13W wim, Rated Voltage Vm' 54.7 V PP 3 Rated Current impp5 98 A v2 N Open Circuit Voltage Voc 64 9 V 1 200 W/ml Short Circuit Current ISC 6 46 A 0 II 0 10 20 30 40 50 60 70 Maximum System Voltage UL 600 V Voltage M Temperature Coefficients Power(P) -0 38%/K Cirrent/voltage characteristics with dependence on irradiance and module temperature Voltage(Vac) -176 6nnV/K Current(ISC) 3 5mA/K , TESTED,OPERATING CONDITIONS NOCT 45'C+/-2'C Series Fuse Rating 20 A Temperature -40'F to+1185*F(-40'C to+85'C) 113 psf 550 kg/M2(5400 Pa),front(e.g snow) Grounding Positive grounding not required Max load W/specified mounting configurations MECHANICAL DATA 50 psf 245 kg/M2(2400 Poll front and back (e.g.wind) Solar Cells 96 SunPower Maxeon"'cells Front Glass High-transmission tempered glass with Impact Resistance Hail (25 Trim)at 51 mph(23 m/s) anti-reflective(AR)coating Junction Box IP-65 rated with 3 bypass diodes Dimensions:32 x 155 x 128 Trim WARRANTIES AND CERTIFICATIONS Output Cables 1000 Trim cables/Multi-Contact(MCA)connectors Warranties 25-year limited power warranty Frame Anodized aluminum alloy type 6063 (black) 10 year limited product warranty Weight 41,0 lbs(18.6 k9) Certifications Tested to UL 1703.Class C Fire Rating DIMENSIONS I r" 4'3 MM (A)-MOUNTING HOLES (B)-GROUNDING HOLESO'l (IN) 12X 06 6(261 10X042(,17) 2 BRIH ENDS—] .16 '81 (A) 12 17 Please read safety and installation instructions before using this product, visit sunpowercorp.com for more details. 0 2011 SunPower Corp000nSUNPOVVER,the St,ok—,Logo,and THE WORLD'S STANDARD FOR SOLAR,.,d MAXEOq..trademarks.,registered toad.—ks sunpowe rcorp.com of S'opCo'p.oatm it..US and.16,c—Inas as well All R,94ls Reserved Speofical—in-luded in this d—sheet am s,bject to change milimt not ce, D.c,..n,#001.5464 R-'B/[1R_EN 4 w-4 A A 3 4 SIPS M, THE WOREWS ONLY S14 'TIN, SECURE POWER SUPPLY t a T 'M ft ym -2,....................... 'Z is A Certified Innovative Powerful Flexible Ul.1741 and 1699E compliant •Secure Power Supply provides -97.6%maximum efficiency -Two MPP trackers provide Integrated AFCl meets the require- daytime power during grid outages -Wide input voltage range numerous design options ments of NEC 2011 690.11 -Shade management with OptiTrac -Extended operating Global Peak MPP tracking temperature range SUNNY BOY 300OTL-US / 38GOTL-US /400OTL-US 500OTL-US / 600OTL-US / 700OTL-US / 770OTL-US Setting new heights in residential inverter performance The Sunny Boy 300OTL-US/380OTL-US/AOOOTL-US/500OTL-US/600OTL-US/700OTL-US/770OTL-US represents the next step in performance for UL certified inverters.Its transformerless design means high efficiency and reduced weight.Maximum power production is derived from wide input voltage and operating temperature ranges. Multiple MPP trackers and OptiTracTm Global Peak mitigate the effect of shade and allow for installation at challenging sites.The unique Secure Power Supply feature provides daytime power in the event of a grid outage. High performance flexible design and innovative MEfeatures make the Sunny Boy TL-US series the first choice among solar professionals. 0 -14,o Impog-R Sunny Boy 300OTL-US Sunny Boy 3800TWS Sunny Boy 400OTL-US Technical data 208 V AC 240V AC 2.08 V AC 240 V AC 208 V AC 240 V AC Input(DC) Max usable DC power(a0 cosy-1) 3200 W 4200 W 4200 W Max.DC voltage 600 V 600 V 600 V Rated MPPT voltage range 175•-480 V 175-48 0 V 75-480 V MPPT operating voltage range 125-_500 V- 125-500 V 125-500 V Min-DC volta9e/start voltage 125,V/150 V 125 V/'150 V 125 V/150 V Max.operating input current/per MPP tracker 1.8 A j 15 A 24 A/15 A 24 A/15 A Number of MPP trackers/strings per MPP tracker 2/2 Output(AC) AC nominal power 3000 W 3330 W 3840 W -4000 W Max.AC apparent power.,_ 3000 VA `3330 VA 3840 VA 4000 VA,_ Nominal AC voltage/adjustable 208V/0 240 V/0 208 V/• 240 V/• 208V/0 2d0 V/ib AC voltage range 183-229 V 211 -264V i83-229V 211 -264 V 183-, 229V 211 -244V AC gnd frequency,range 60 Hz/59.3-60.5 Hz 66 Hz/59"3-60.5 Hz 60 Hz/59.3-60.5 Hz Max.output current 15 A 16A -20A _ Power factor(cos T) ` I - I 1 Output phases j line connections 1/2 1/2 _ 1/2 Harmonics <;d%•_ <4% <4%' Efficiency Mai,efficiency, 972% _ 97.6io 97.2%- 97.5% 97.2% 975% CEC efficiency 96.5% ` 96.5 a 96.5% 97.0% 96.5% 97.0% Protection devices DC disconnection device • DC reverse-polarity protection _ • Ground fault monitoring/Grid monitoring •j�► AC short circuit protection All-pole sensitive residua)current monitoring unit a _ Arc fault circuit interrupter(AFCI).comphant to UL 16996 Protection-class/oyervoltage category. I/IV General data Dimensions(W/H j D)in mm(in) 490/51§/185 (19.3 DC Disconnect dimensions(W/H j D)in mm(in) 187/297/190 (7.4 j 11_7/7.5) Packing dimensions(W f H/D)in mm(in) - Y 617/597/266 (24.3/23.5/10"5) DC Disconnect packing dimensions(W/,H/D)in mm(in) 370/240 j 280 (14.6 j 9.4/11.0) ,Weight/DC Disconnect weight. 24 kg (53161/3.5 kg (8 16) Packing wet ght/DC Disconnect packing weight 27 kg (60 lb)/3.5 kg (8 Ib) Operating temperature range -40-C +60-C (-40,°F...+l40'F) Noise emission(typical) 5 25 dB(A) <25 dB(A)• <25 dB(A). Internal consumption at night <1 W <1 W <1 W Topology Tronsformerless_ _ TransFormerless Transformerless Cooling Convection Convection Convection Electronics protection rating NEMA 3R NEMA 3R NEMA 3R ' Features Secure Power Supply a _. Display:graphic • Interfaces:R5485/Speedwire/Webeonnect 00 0/0 0/0 Warranty.10/15/20 years */0/0 ®j0j0 6/0/0 •-Certificates and permits(more,available on request) UL 1741,UL 1998,_UL 1699B,IEEE1547,FCC Part..15(Class A&B),CAN/CSA C22.2 107.1-1 NOTE:US inverters ship with gray lids Type designation SB 3000TL--US-22 SB 3800TL-US-22 SB 400OTL-US-22 ,. b s _ ----- --------------- ---- ------------- Efficiency curve SUNNY BOY SOOOTL--US-22 24OVac-------------------------- Aeeessodes „,�••- Saeedwre,`Webmrnetl R5485 interface 96 ..........�................. interface DM-485C11-US10 f,..i. .........„.. .. ...........E SWDM-USSO 94 a 92 �.• ray kt for SB 3000/3800/ ' ;w 90 4000/5040TL-US-22 ••• Eta(V„-175 V)L, c 96 8B Eta(Vw-400 Vl 86 Eta IV.,-480 V1, V-IV, aao 1 __ 0.0 0.2 0.4' 0.6 08 10 i -- •,Output power/Rated power i D Standard feature r d 0 Optional feature Not available :....... ----- ---11-.-.---.-.----- ----------- Data at nominalconditions Sunny Boy 500OTL-US Sunny Boy 6000TL-US Sunny Boy 7000TL-US Sunny Boy 770OTL-US 208 V AC 240 V AC 208V AC 240V AC 208 V AC 240 V AC 208 V AC 240 V AC 5306W 6300 W 7300 W 8000 W 600 V 600 V 600 V 600 V 175-486 V 210-480V 245-480 V 270,7 480 V 125-500 V 125-500 V 125-500 V 125-500 V 125V/150V 125V/150V 125V/i50V 125V/150V 30A/15A 30A/15A 30A/18A 30A/18A 2/2 4550 W 5000 W 5200 W 6000 W 6000 W 7000 W 6650 W 7680 W 4550 VA 5000 VA 5200 VA 6000 VA 6000 VA 7000 VA 6650 VA 7680 VA 208 V/• 240 V/e 208 V j• 240 V/• . 208 V1• 240 V/• 208 V/0 240 V/• 183-229V 217-264 V 183-229 V 211 -264 V 183-229 V 211 -264 V 183-229 V 211 -264 V 60 Hz J 59.3-60.5 Hz 60 Hz/59.3 -60.5 Hz 60 Hz/59.3-60 5 Hz 60 Hz J 59.3-60 5 Hz 22A 25 A 29.2 A 32A 1/2 1/2 1/2 1/2 <4% <4% <4% <41. 97.2%, 976% 97.0% 974% 968% 46.8% 96 8%_ 97.3°% 96.5% 97.0% 96.5% 97.0°% 965% 96.5% „- 96.5% ,96.5% t/IV 490/519/185 (19.3/205/7.3) 187/297/190 (7.4/11.7/7.5) 617/597/266 (24-3/23.5/10 5) 370/240/280-(14.6,/9.4/11.0) - 24 kg (53 Ib)/3.5 kg (81b) _ 27 kg (60 Ib)/3.5 kg (81b) .-40-C., +60°C 1-40'F.. +140°F) <29 dB(A}- <29 dB(A) _<29 dB(A) <29 dB(A) <1W <1W <1W <1W _Transformedess Transformerless Transformerless Tronsformerless Convection Fan Fan Fan NEMA 3R NEMA 3R NEMA 3R- NEMA 3R 0/0 0/0 -. O/'O 0/0 •/0/0 0/0/0 0/0/0 •/o/o UL 1741,UL 1998,011699B,1EEE1547,FCC fart i5(Class A&B),CAN/CSA C22.2 107.1-1 SB 5000TL--US•22 SB 600OTL-US•22 SB 7000TL.US•22 SB 7700TL.US•22 ON WMore efficient Shade management Easier h n Secure Power Supply Broad temperature range Flexible communications A NEW GENERATION OF INNOVATION THE SUNNY'BOY TL-US RESIDENTIAL SERIES HAS YET AGAIN REDEFINED THE CATEGORY. Transformerless design in all types of climates and for longer periods of Leading monitoring time than with most traditional string inverters, and control solutions The Sunny Boy 3000TL--US / 3$OOTL-US / 4000TL-US / 5000TL-US / 6000TL-US / Secure Power Supply The new TL-US residential line features more 3 7000TL-US/7700TL-US are transformerless than high performance and a large graphic inverters; which means owners and installers One of many unique features of the TL-US display. The monitoring and control options benefit from high efficiency and lower weight. residential series is its innovative Secure 'provide users with an outstanding degree of A wide input voltage range also means the Power Supply. With most grid-tied inverters, flexibility. Multiple communication options F inverters will produce high amounts of power when the grid goes down, so does the solar- allow for a highly controllable inverter under a number of conditions. powered home. SMA's solution provides and one that can'be monitored on Sunny f daytime energy to a dedicated power outlet Portal from anywhere on the planet via an z, Additionally, transformerless inverters have during prolonged grid outages, providing Internet connection. Whether communicating a been shown to be among the safest string homeowners with access to power as long as through RS485,or'SMAs new plug-and-play inverters on the market.An industry first,the TL- the sun shines. WebConnect, installers can find an optimal US series has been tested to UL 1741 and UL solution to their monitoring needs. 1699B and is in compliance with the arc fault Simple installation requirements of NEC 2011. Wide Power Class Range As a transformerless inverter, the TL-US Increased energy production residential series is lighter in weight than Whether you're looking for a model to 5 its transformer-based counterparts, making maximize a 100 A service panel or trying s OptiTracTm Global Peak, SMA's shade- it easier to lift and transport. A new wall to meet the needs of a larger residential PV tolerant MPP tracking algorithm, quickly mounting plate features anti-theft security and system, the Sunny Boy TL-US with Secure adjusts to changes in solar irradiation,which makes hanging the inverter quick and easy.A Power Supply has you covered. Its wide mitigates the effects of shade and results in simplified DC wiring concept allows the DC range of power classes—from 3 to 7.7 kW— higher total power output.And,with two MPP disconnect to be used as a wire raceway, offers customers the'right size for virtually any trackers, the TL-US series can ably handle saving,labor and materials. residential application.The TL-US series is not complex roofs with multiple orientations or only the smartest inverter on the planet,it's also r string lengths. The 3800TL--US and 7700TL-US models allow the most flexible. installers to maximize system size and energy v An extended operating temperature range of 'production for customers with 100 A and 200 -40*F to+140 'F ensures power is produced A service panels. > Toll Free+1 888 4 SMA USA www.SMA-America.com SMA America, LLC 7MV _71� n Simple and Fast Installation lriLegrated module-Lo-rdil gro-inowig b P, mid and eno r.lamp, Levitating mio ca,ip for easy place-lent M d clamo vvidtn ev2n Inocule spar.-ing Sirrp'e,pre-dr tIM rail-,plire U�2703 ustec integrates groundirg Flexible Des'on Md,esses newly all sloped residenti-al''Ooff Design h lardscape and po,vai-_ wilble eas,obst—le rranagemprIt M Rails,pi iT 4 Customer-Preferred , - -Preferred Aesthetics 4"1 module arc H..; mounting aesthezics Best-ir-class system aestriezirs Regan-, Simplici:y Prcrriurn,low-prolile desigr, Mac;<anodized components Sunrlowerl- lf)V,S:VOUrW" is a Sunilower-designec I lidder mid c,amp�and end Jqm,-.,s rail-based -)our,,,,-!rig system. The Invis!Mo_,rA systern -)ardwa,c,ar,,e r@poed,flush rails addresses res dcrtial slon,,'c roofs and cor-r)bir-,(,s faster Part of Superior System installation time, design fiexbility, and superior aesthetics Buh-lu€ use with Sur 'owe DC Urid AC r-iocyius The InvisiMourt orccuct was specifically e,Vsioned and Be-st-ir-class sk/stern mliability arc:aes-ft et:(.s Combire wtr SUnPoWel-modeles and enginee-eo to pa'r with Sun�ower modules Ti-ie -est IT,n- moritor:n,,apo sys-,em-level aDproachvvll arnplif,,/'l,e aesthetic anc, installation benef is for botr -ome-owners and installei-s. sunpower.com .............. -T� 7,�4 '77'777 Agk 6, ................. R ......................... Modu el I Mici Clamp and Rail ClarP and Rail M di Camp rn Uzr" Pad P Rai'SJ)lr'e G,ound Li&'As;errnbly F-nd(ap Tornorat,.(e -4C,"'-,o 90",(-40'F to 1a,`r) rv'aterfl p —1----- 7 - ---I------.................... Max l"n'! 24CC,'Pa,plift MI (Iarlp >ilac,(,)x,d, ',,ai�1 e A'Sl 37= 63 (2 2 oz) Paco,,Avi-iforce i-nd r-I.,,rrP 3[ackanco-z--d,i!u-n-,;;-n g(3 88 BlacKanonizcd al-i-n-i-n I c.'Iloy r'r,05--ie 830WIn"S OLIQ -ar prcci,,ct,,qarrAn,, Rail cphre Alt-rrimurr,all E60--, HU-'�wrr(9 J warfar'les 125 - ---- - - 1 5-v 304 q?mass' ear-firijs� vmrfar�'Lv ound LL,g i 7F 'I G6 q g/fI Av;efnbly IDOIL,tin<,Iaced ccoocf lug) I.,L 2733 Lis-ca , Fn d an 31a(-k (')Olv',)coo1jrnpr V4 g(U 7 CA Corificatic"Is Class A fire--3t,,78.,when j stance bet's ee^ module;-ante is i,'3 1," Compos on Sl` ,,,le Rafle-A,Iaulnlen' Applicat ,,or S.Ir-a[--Roo�Pecking Attachrien-, ci,� I � Cur ved and Flat T e A*[a-Ir'rent Universal Ir'erfice for Ot',PrRo(,`At:.-chmprw, Refer tc rc,(,;att,:iJii nei it hercovare mariuMo t.rer's dlo,ur ientFtl(,n eqoiiedloi-mv.•ire imercpe,abf:q �0"S S,fnP,,.,.,er,'orx,zvon Ail Rtr,P saved �:-T,�OIVS,thc-SI,:IJPOt,^,/rR INVlSIr,,ICi,NT arc trde-a, or qpsrer:d "Idode'j�vhls W chd^Fe tl'011��Ut IIcUcQ -)on vmp-;150 jl),.36 Rev 3