Loading...
HomeMy WebLinkAbout40567-Z Town of Southold 8/30/2016 o - P.O.Box 1179 o 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38481 Date: 8/30/2016 THIS CERTIFIES that the building AS BUILT ALTERATION Location of Property: 590 Windward Rd., Orient SCTM#: 473889 Sec/Block/Lot: 14.-2-30.5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/21/2016 pursuant to which Building Permit No. 40567 dated 3/28/2016 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"alteration for a finished basement in an existing one family dwelling as applied for. The certificate is issued to Kougentakis,Petros&Anna of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40567 6/8/2016 PLUMBERS CERTIFICATION DATED 5/26/2016 Burt's Reliable Inc. Autb ed Signatur �gUFfO( TOWN OF SOUTHOLD BUILDING DEPARTMENT a TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40567 Date: 3/28/2016 Permission is hereby granted to: Kougentakis, Petros 590 Windward Rd Oriet, NY 11957 To: legalize "as built" alterations to an existing single family dwelling as applied for. At premises located at: 590 Windward Rd., Orient SCTM # 473889 Sec/Block/Lot# 14.-2-30.5 Pursuant to application dated 3/21/2016 and approved by the Building Inspector. To expire on 9/27/2017. Fees: CO -ALT O DWELLING $50.00 AS BUILT- SINGLE F Y ADDITIO T ATION $2,453.60 otal: $2,503.60 9 Inspector �'" pF SOUK,®l Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 ® roper.riche rt(aD-town.southold.ny.us Southold,NY 11971-0959 ®l�C®wn BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To. Kougentakis Address: 590 Windward Road City: Orient St: New York Zip: 06390 Building Permit# 40567 Section 14 Block: 2 Lot- 30.5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: AS BUILT DBA: License No: SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 12 Ceding Fixtures 1 HID Fixtures Service 3 ph Hot Water GFCI Recpt 2 Wall Fixtures Smoke Detectors Main Panel A/C Condenser 1 Single Recpt Recessed Fixtures 8 CO Detectors Sub Panel A/C Blower 1 Range Recpt Fluorescent Fixture 8 Pumps Transformer Appliances Dryer Recpt 20A Emergency Fixtures Time Clocks Disconnect Switches 9 Twist Lock Exit Fixtures TVSS El Other Equipment- 1- Exhaust Fan Notes: "AS BUILT'-"ELECTRIC SURVEY"-"NO VISUAL DEFECTS" Inspector Signature: = Date: June 8, 2016 z Electrical 81 Compliance Form(2)As Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 Date. AA 211 2d New Construction: Old or Pre-existing Building: (check one) Location of Property: o o VIJ 1 (V t \�_/1� F_0 Rb A House No. Street Hamlet Owner or Owners of Property: y; LSA C— PJ Suffolk County Tax Map No 1000, Section 14 Block Lot 3 Subdivision ( Filed Map. Lot: Permit No. y 5y' Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: / Request for: Temporary Certificate Final Certificate: y (check one) Fee Submitted: $ Applicant Signature f____ May 26 16 11:08a P•2 01/ ILI Town Hall Amiex �&• Telephone(631) 765-1802 54375 Main Road P.O.Box 1179 Fax(63I)765-9502 � � �Q�l Southold,NY 11971-0959 BUILDINEG DEPAR D TMEi�IT D TOWN OF SOUTHOLD JUN 1 0 2016 SUMDING DEFT. CERTIF7CATTON TOWN OF SOUTROLD Date: Building Permit No. Owner: P/ OAC �tJ Lt' (Please /print) V r Plumber: DGv� , !7�e �� d r�i' � f R&1�4-01161 (Please print) I certify that the solder used in the water supply system contains less than 2/10 of t% Lead. lumbers / Signature) Sworn to before me this day of �`(1a, 24_� Notary Public, `� � t:oUnty ALICIA WALKER Notary Public State of New York No.OIWA6153064 qualified in Suffolk County Cornmission Expires Sept.25,N fie TOWN O SOUTHOL-D BUILDI G-DE T. 765-1802 1 cTI [ ] FOUNDATION IST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INSU [ ] FRAMING /STRAPPING [ INAL [ ] FIREPLACE & CHIMNEY [ -.] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: 4 / � - - DATE ( � INSPECOR OF SO(/T�°lo - �;c�1 TOWN OF SOUTHOLD BUILDING DEPT. - 765-1802 INSPECTION- [ ] FOUNDATION IST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INSULATION- ] FRAMING / NSULATION- ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE � ' INSPECTOR [RC [R�V[a .5408. V JUm 16 201 EUII•DINGDEPT• us; �� TOWN OF SOUTHOLD SANDOR WEISS , R. A . ARCHITECT June 15, 2016 RE: 590 Windward Road Orient, New York 11957 BP #40567 To Whom It May Concern: Please be advised that after reviewing the plans & upon site visit, we certify that all work was performed under BP #40567 as per plans. Work included in the plan incorporated new gypsum board at walls and ceilings with insulation and ceramic tiles @ bathroom with electrical & plumbing work as needed. Sincerely yours, ,--R /}, Sandoz,;Q ,Ar 143 COQ' COF N. ad 1508 Avenue J • Brooklyn • New York • 11230 Office: (718) 692-0800, (718) 692-0898, Fax: (718) 692-1914 anno.mundi.architect@gmail.com email f i -D u U �1SUSI� � SANDOR WEISS , R. A . ARCHITECT i D L �CDd I AUG 1 7 2016 August 15, 2016 BUILDING DEPT. Southold Town Hail TOWNOFSOUTBf u) 54375 Main Road P.O. Box 1179 - Southold, New York 11971-1179 RE: 590 Windward Road •7 Orient, New York To Whom It May Concern: We herewith certify that calking, framing and footing were done according to New York State 2010 Residential Code. E ARC, { Sincerely yours, JR W � fii Sandor eiss, R.A. c9 0 43'1 Q� 1508 Avenue J • Brooklyn ® New York • 11230 Office: (718) 692-0800, (718) 692-0898, Fax: (718) 692-1914 anno.mundi.architect@gmail.com • ri � - 1 • STATE • •D :i-" �_�. •.. ,�..7; � _/:rte_:�. .:.r'.. _ ,/' y'�. ,✓/�L�..,.%/1'. �,� F I - - i 17 ArM T Fill .. �/ i r TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST\ BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 --4 sets of Building Plans TEL: (631) 765-1802 Planning Boafd approval FAX: (631) 765-9502 — Survey SoutholdTown.NorthFork.net PERMIT NO. Check J • Septic Form N.Y.S.D.E.C. Trustees C.O.Application ,rjl\�\/// Flood Permit Examined ,20 Q Single&Separate D VAR -- Storm-Water Assessment Form 1d�� Contact: Approved ,20 ma :t6T Disapproved a/c , ®LD Y,O V.G E T� =-) TO®VN OF S Phone: 631 Expiration ,20 34_ 355 -525 } ui di spector APPLICATION FOR BUILDIN DateM Svc �I , 20 INSTRUCTIONS a. This application MUST be completelyfilled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applica or n , ' oration) 510 W1,14wGofJ �1- D R re„+ N-1 11 gS?. (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises P 6-7 f,OS Y—O t_c (SEPT� �� (As on the tax roll or latest deed) If applicant;is,,a�corpor4tion;;signature of duly authorized officer ' (Nanie'and:titie'o'f'dorporate officer) Builders`L,icemse✓Nto,:,;�-+,�•_�� i4,;. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which pro osed wok will done: s�(D JIV, 7 - �v c �\ \& 1 K--( 11 ,� S ) - House Number Street ) Hamlet County Tax Map No. 1000 Section 1 Block o� Lot ' Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work (check which applicable): New Building Addition Alteration , Repair Removal Demolition Other Work escription) 4. Estimated Cost od, paid on filing this application) 5. If dwelling, number of dwelling units . ;Number of dwelling . on each floor If garage, number of cars 4 41 1 ij 6. If business, commercial or mixed occupancy, specify na�t�T,'c,� t t of each type of use. e, x�.4.r.,• ,tk8 7. Dimensions of existing structures, if any: Front Dear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO `A, Will excess fill be removed from premises? YES NO *K 14. Names of Owner of premises Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO X * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO X * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO–X—. * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF S P C-T'f.ESS 1`0 V-G C—f"T� being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, TRACEY L. DWYER (S)He is the l�r NOTARY PUBLIC,1 DW630sgo NEW YORK O�(Contr , (Contractor,Agent, Corporate Officer, etc.) QUALIFIED IN SUFFOLK COUNTY COMMISSION EXPIRES JUNE 30,2bL? of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of M�Dzta '� �011M Q.A 20 Notary Pd lic Signature of Applican Scott A. Fussell �0����f�''of ST01K1\\][WA\r]F1E]K SUPERVISOR a IM[ANAG]EAWENT SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 2ll �- Town of So u th o l d CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT) DOES THIS PROJECT INVOLVE ANY OF 'I7(-I]E FOLLOWING: Yes No (CHECK ALL THAT APPLY) EIP A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑0 B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑0 C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑® D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑(� E. Site preparation within the one-hundred-year floodplain as depicted on-FIRM--Map- of any watercourse.- El F. Installation of new or resurfaced impervious surfaces of 1,000 square feet-or more, unless-prior approval-of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT- (Property Owner,Design Professional,Agent Contractor,Other) S-C.T.M. #: 1000 Date: Dutnct �� C p q / NAME: ��©S o C �, _ LJ— 2— Jtl' �J (iO 1 L w , Section Block Lot '+.411p) pL,gn.i FOR Bti,l_D1Nc� r rP A)s"TZ,i=_,NT L t� �)^:l_E' r. Contact Information �3 1 3 2-� �� Reviewed By: JA �)wjjAA Date: Property Address / Location of Construction Work. — — — — — — — — — — — — — — — — ,Q Approved for proce��ing Building Permit sig /�► (,4/t Vy��'� ✓�O a Storrnwater Management Control Plan Not Required o /` NT 1/y - !�/ ! 1:1 Stormwater Management Control Plan a Required (Forward to Engineering Department for Review) FORM 4 SMCP-TOS MAY 2014 fg SO�lyo Town Hall Annex J6 lit Telephone(631)765-1802 54375 Main Roadv, (631)765- 5 P.O. Box 1179 Q roger.richert fown.sout�iol .ny.us Southold,MC 11971-0959 Q BUILDING DEPARTMENT TOWN OF SOU THOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY- Date: Company Name: Name: L T`(�� � G C INJ T FA License No.: Address: 5')0 w/.V1 W a YJ Q j �-A/T Phone No.: 2v, 9 f-,6 7 JOBSITE INFORMATION: (*Indicates required information) *Name: *Address: *Cross Street: IV *Phone No.: Permit No.: Tax-Map District: - 4000 Section:- Block: Lot: *BRIEF DESCRIPTION OF WORK(Please Print Clearly) (Please Circle All That Apply) Is job ready for inspection: YES / NO Rough In =Final "Do-you need a Temp Certificate: YES/ NO Temp Information (i needed) 'Service Size: 1 Phase 3Phase 100 450 200 300 350 400 Other 'New Service: Re-connect Underground Number of Meters Change of Service Overhead 4dditional Information: PAYMENT DUE WITH APPLICATION 3 Q - O 82-Request for Inspection Form 0 0 - ,70, . TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET � � VILLAGE DIST. SUB. LOT f Tads Nnn, Q_ On �_ '�r I ('�a B•e-eat-ick loo-s i_t Ir, FORMER OWNER NE ` ah fr n I 5 ro kQ vj �t{ +,.�. ACR. S W ` ' TYPE OF BUILDING e S L Q 0 B L D C3 RES. 2L SE S. VL. ,�,•` r FARM COMM. CB. MISC. Mkt. Value G � LAND IMP. TOTAL -DATE REMARKS © 0 0-�i SIA d, 4 s4s p ',5 A t-i-i e(rc, -4m Fo4e-xr f �- Y �Pb v' G v14 �5'45 9- "t�Z��� .ti Gtcr�c Ya rtrr ti 1 1 J'-� S-4 U1L CODITI N 3 aP2% -Are ay1 k/o u c,e n iv kl's 419 3snc�) 700 114.1-ahl s191 -gp` o/ s- cot)SA on e- 3500 x0 7©0 11 cg' q _ Tillable 1 :,t -- �_67- Ti3ble 2 J 4 �\ �b 1�24b � •l•5 t(a �-- �c�' • `N c s-c.�cc. � �t `` ���a� 1 �� �b 1 Tillable 3 y Woodland Swomptand FRONTAGE ON WATER =4? Brushland FRONTAGE ON ROAD House Plot DEPTHtrz`" ! BULKHEAD Total i /�, a•,- DOCK 1. ■■■■■■ NN OMEN ■■■■■■■ MEMMO !�IEEEMEN■■■■■■■ £. MONO■ ■■■NON■■■■■■■■■■■■■ y OM■■E■M M■■MM►MEEM■M■MENMMM MEZRUMMENUMEWMEM - - ■MM■M■M rE�■Oil■®C�■■■■OL�OO■NM MEN NENSC W MfilMr:�®IRS EMBIRE ME SOMME ■■■■tic■■M■ s # � K. } Y rte, ON ■MO \■�llMMi�r■■F�,■■■■M■■ E■ Obi ■■MMONO NNENEONMEN ■■ r r ' • • w Interior Rooms 2nd oor • N t 2C e M r• • rL pF SOUIy®l Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 �l� �� COUNT`I April 25, 2016 BUILDING DEPARTMENT TOWN OF SOUTHOLD Petros Kougentakis 590 Windward Rd Orient NY 11957 RE: 1230 Washington Ave,Greenport TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: NOTE: Inspector is requiring all work done under this permit to be certified by an architect or engineer. Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of$50.00. inal Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) V Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT - 40567—As Built Alterations GENERAL NOTES: 1. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS �`� IN THE FIELD PRIOR TO COMMENCING WORK. 2. THESE NOTES ARE PART OF THE PLANS AND SPECIFICATIONS AND ARE 00 C TO BE COMPLIED WITH IN ALL RESPECTS. MORE RESTRICTIVE NOTES 22: �. < E, " O MENTIONED ELSEWHERE ARE TO TAKE PRECEDENCE OVER THE FOLLOWING. I `� 3. THE CONTRACTOR SHALL BE RESPONSIBLE TO FAMIUARIZE HIMSELF THOROUGHLY WITH r `\` IM to ���~ CV SPECIFICATIONS, FIELD CONDITIONS AND OTHER REQUIREMENTS OF THIS �' "" ""'" _ ALL DRAWINGS, SPE � ``� �• � m..,�, .�..�. PROJECT AND SHOULD REPORT ANY DISCREPANCIES TO THE ARCHITECT. _ - J o 4. THE CONTRACTOR SHALL DIRECT AND SUPERVISE THE WORK. THE CONTRACTOR yam'' "~ �' i.r} I� rel H �. py�' OQ SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, �'`� { '' ' CII':''' ' M TECHNIQUES, SEQUENCES, PROCEDURES, AND SHALL COORDINATE THE WORK. `••• 5. THE CONTRACTOR SHALL BE HELD TO HAVE VISITED THE SITE SO THAT HE ��. MAY DETERMINE THE DIFFICULTIES HE MAY ENCOUNTER DURING CONSTRUCTION. r, 6. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NEW YORK CITY t ` ry �.. -i, r,;s n (� �� �>.,�, „rte.... ....•.•i� BUILDING CODE, FIRE DEPARTMENT REGULATIONS, DEPARTMENT OF HIGHWAYS, ' `�" t^'. Fr ;. ,,li'C �; ::.�S•. ,? -,`� UTILITY COMPANY AND THE BEST TRADE PRACTICES. 7. THE CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY �': CCS;',"^!_._I r �,•' '. C.O. DAMAGE OR INJURIES CAUSED BY OR DURING THE (EXECUTION OF THE WORK. {{{ ALL r Er THE S A N D O R W E I S S R. A. 8. THE CONTRACTOR SHALL LAY OUT HIS OWN WORK, AND SHALL PROVIDE ALL ;; ;�`:.J R ;�,"F �j • DIMENSIONS REQUIRED FOR OTHER TRADES (PLUMBING, ELECTRICAL, ETC.). I -,�-�� �;--��-� NOT . ,. ^� �P, 1317 AVENUE J BROOKLYN NY 11230 9. PLUMBING AND ELECTRICAL WORK SHALL BE PERFORMED BY PERSONS LICENSED IN THEIR r'_ , l r,r�. f:rJ• I Sr Uti� BLE ri�F TRADES, WHO SHALL ARRANGE FOR AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS. I G?�ES-0-l GP CO dv I`F;UCTIG`� ERRORS, (718)692-0800- DI.A 692-0898 ITECTO 10. THE CONTRACTOR SHALL DO ALL CUTTING, PATCHING, REPAIRING AS REQUIRED TO FAXp18)692-1914-ANNO.MUNDI.ARCHITECT®GMAIL.COM PERFORM ALL OF THE WORK INDICATED ON THE DRAWINGS, AND ALL OTHER WORK THAT I S C O P E O F W O R K MAY BE REQUIRED TO COMPLETE THE JOB. I OW1,4 CODES SCOPE OF WORK: 11. ALL PIPING AND WIRING SHALL BE REMOVED TO A POINT OF CONNECTION AND SHALL BE PROPERLY CAPPED OR PLUGGED. A PROPOSED INTERIOR ALTERATION TO BUILDING, (AS PER PLAN) 12. THE CONTRACTOR, UPON COMPLETION OF THE WORK, SHALL ARRANGE FOR NOTE: DEPARTMENT OF BUILDINGS INSPECTIONS AND SIGN-OFFS REQUIRED TO COMPLETE I _ . ._ .,SC,1;'',G_�i011,N Z"li, NO CHANGE IN USE, OCCUPANCY, EGRESS , BULK OR ME'T'ES BOUNDS THE JOB AND PROVIDE ALL CONTROLLED INSPECTIONS AS REQUIRED BY THE BUILDING Yr DEPARTMENT FOR THIS PROJECT. I I -------- - - _- 13. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS SHOWING LAYOUT, PROFILES, METHODS OF JOINING AND ANCHORAGE DETAILS, INCLUDING MAJOR FINISHING AND TRIM UNITS. PROVIDE LAYOUTS AT 1/4" SCALE AND DETAILS AT 3" SCALE. I -- ----• 14. THE DRAWINGS REFLECT CONDITIONS REASONABLY INTERPRETED FROM THE EXISTING VISIBLE CONDITIONS OR FROM DRAWINGS OR INFORMATION FURNISHED BY THE OWNERBUT CANNOT BE GUARANj Y 15. ALL CONSTRUCTION SHALLEED COMP Y WITH STATEBY THECANID OTHER LOCAL BUILDING CODES & ! '^ a r ' ' OR REGULATIONS AND THE BEST TRADE PRACTICES. I ALL PROVIDE SUCH LABOR MATERIALS AND EQUIPMENT AS REQUIRED ° '� ULP►WF11 RrTlPw STdS'�!,1 ��,rTER R�1P1�FF 16. THE CONTRACTOR SH ' FOR THE TIMELY COMPLETION OF THIS WORK, AND TO COMPLETE THE PROJECT AS SHOWN. f I �dT JOI JT CERTIICI�TE ^';^Ai!M,',;T TO CH�',.'TL�, 23 17. MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR THE PROPER 1 t <; I rn'R� CONSTRUCTION, INSTALLATION OR OPERATION OR ANY PART OF THE WORK AS DETERMINED V OCCUPANCY BY THE ARCHITECT SHALL BE INCLUDED IN THE WORK AS IF IT WERE SPECIFIED OR I v INDICATED IN THE DRAWINGS. I 18. ALL MATERIALS SHALL BE INSTALLED PROPERLY, FOR THE USE INTENDED, IN ACCORDANCE , ` WITH THE MANUFACTURE'S WRITTEN INSTRUCTIONS AND TO THE HIGHEST STANDARDS , ( LEGEND OF THE TRADE. `' «Y1 y~ 19. BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE FOR ALL REQUIRED CERTIFICATES OF INSURANCE WITH THE DEPARTMENT OF BUILDINGS, OBTAIN ALL I ' rF ^yi4 t _ REQUIRED PERMITS, CONTROLLED INSPECTIONS, INSPECTIONS AND SIGN-OFFS, I ��� -•'' ''°"' ' A DOOR KEY (SEE SCHEDULE) PAY ALL RELATED FEES AND PRESENT COPIES OF APPROVALS FOR FINAL ACCEPTANCE WINDOW KEY (SEE SCHEDULE) BY THE OWNER INCLUDING FINAL CERTIFICATE OF OCCUPANCY. � I PLU�B�NG W ING WASTE o !" ALL PLUMB 20. THE DRAWINGS ARE NOT TO BE SCALED, ONLY DIMENSIONS ARE TO BE USED. I I CALLED TO THE ARCHITECT'S ATTENTION. ' &V'JATER LINES NEED 3 5/8" METAL STUDS @ 16" O.C. w/(1) LAYER, FC #60, ALL DIMENSIONAL DISCREPANCIES SHALL BE ALL DIMENSIONS SHALL BE VERIFIED BEFORE STARTING WORK BY THE RESPECTIVE '� TESTING BEFORE COVERING 5/8"THK G.W.B. ON BOTH SIDES, (1) HR FIRE RATED, F BSA CAL#301-60 SM SUBCONTRACTOR, WHO SHALL BE HELD RESPONSIBLE FOR HIS PHASE OF THE WORK. 00 VERIFY EXISTING FRAMING, REVIEW WITH ARCHITECT ALL EXPOSED CONDITIONS WHERE fV NEW CONSTRUCTION IS SUPPORTED BY EXISTING CONSTRUCTION ' 21. ALL CONSTRUCTION, DIMENSIONS AND DETAILS SHALL CONCUR WITH AND BE DETERMINED � '»"'' �'"�""�� ' O SMOKE/CARBON MONOXIDE DETECTOR RTAILS A SKETCHES ISSUED BY THE I �"v(fr�',�R C'�RTI. f' � A S/C FROM THESE DRAWINGS AND REVISED D vrt. '" " ""' TO BE INTERCONNECTED IN SUCH A MANNER ARCHITECT ONLY. ..� �'��� y` '� A * • THAT THE ACTIVATION OF ONE ALARM OR DIMENSIONS ON PLAN SHOWN AS PLUS OR MINUS (f, +, -) ARE TO BE CLARIFIED IN THE I G�RTIF3 _ DETECTOR WILL ACTIVATE ALL THE ALARMS ` �� ! "�/� OR DETECTORS IN DWELLING UNIT. FIELD AND DISCREPANCIES OF GREATER THAN 2" ARE TO BE REPORTED TO THE ARCHITECT. ( �DyDrR USED 1�J�.. '�" 22. ALL MATERIALS, ASSEMBLIES, FORMS AND METHODS OF CONSTRUCTION AND SERVICE ' " t�7 i �".., MV MECHANICAL VENT., 75 CFM FOR BATHROOM, 100 EQUIPMENT SHALL BE MET WITH THE FOLLOWING REQUIREMENTS: 19 -1 = $�1 ,r LYSYSI'C..: MECHANICAL SYSTEM PIPING R-3 "� CFM FOR LAUNDRY ROOM 8, 150 FOR KITCHEN B. SHALL BE ACCEPTED FOR USE UNDER THE PRESCRIBED CODE TEST METHOD BY THE I I '�° R-2. CIRCULATING HOT WATER COMMISSIONER OR ' DRAWINGS LIST C. HAVE BOARD OF STANDARDS AND APPEALS APPROVAL. ! qq' 23. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY SERVICES AND UTILITIES 23'_ fVl A001 .00 SITE PLAN, ZONING ANALYSIS, LEGEND DURING THE CONSTRUCTION PERIOD, AND SHALL PAY ALL COST INVOLVED. A002.00 EXISTING BASEMENT & FIRST FL. PLANS 24. THE CONTRACTOR SHALL CARRY BUILDERS RISK INSURANCE WITH BROAD FORM COVERAGE COVERING THE VALUE OF HIS COMPLETED WORK. A003.00 EXISTING 2nd FLOOR 25. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY PROTECTION, SECURITY AND A004.00 PROPOSED BASEMENT & 1ST FL. SAFETY OF THE SITE DURING CONSTRUCTION. I PIPE 26. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, DISTORTION _ HOT WATER A 5• DETAILS AND MISALIGNMENT ACCORDING TO APPLICABLE CODE STANDARDS AND GOOD PRACTICE. ' I (SERVICE WATER PIPE) ABBREVIATIONS 27. THE CONTRACTOR SHALL PROVIDE A REFUSE CONTAINER AT THE SITE AND SHALL CLEAN UP I HIS DEBRIS AT THE TIME OF COMPLETION OF EACH WORK DAY. I REQUIRED PIPING INSULATION FOR HOT WATER 28. ALL CONSTRUCTION SHALL BE AS PER PLANS AND SPECIFICATIONS UNLESS OTHERWISE @ AT LIN. LINEN AGREED IN WRITING BY THE OWNER. r I (SERVICE WATER PIPE) (MECH PIPING) BD. BOARD MTL. METAL 29. NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL BY I PIPE INSULATION DETAILS CL. CLOSET RM ROOM THE ARCHITECT. C.B. CONCRETE BLOCK RD ROOF DRAIN 30. ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR INSTALLATION I OF ANY EQUIPMENT AT BUILDING SITE. I SCALE: N.T.S CONC. CONCRETE S. SINK 31. THE CONTRACTOR SHALL BE RESPONSIBLE TO THE OWNER FOR ALL ACTS AND OMISSIONS DR DRAIN S.F. SQUARE FEET DN DOWN S OF HIS EMPLOYEES, AND ALL SUBCONTRACTORS, THEIR AGENTS AND EMPLOYEES AND ALL ' ( IL. STEEL SHEET D.U. DWELLING UNIT L. OTHER PERSONS PERFORMING ANY OF THE WORK TO BE DONE. DWG. DRAWING TYP. TYPICAL 32. IT IS THE INTENTION OF THIS CONTRACT TO COMPLETELY FINISH AND READY FOR ! F.P.S.C. FIRE PROOF SELF CLOSING W/ WITH OCCUPANCY THIS BUILDING IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND , ALL REQUIREMENTS OF LAWS. ALTHOUGH NECESSARYGYP. GYPSUM WD. WOOD IWORK MAY NOT BE ITEMIZED IN ` 33. THE DRAWINGS THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE EXISTING I FT. FOOT (FEET) W.C. WATER CLOSET CONDITIONS AND INCLUDE ALL WORK SPECIFIED OR IMPLIED FOR THE COMPLETION - I LAV. LAVATORY W/D WASHER /DRYER OF THIS BUILDING. i ( G/H GREEN HOUSE II � THE ARCHITECT SHALL NOT HAVE CONTROL OR CHARGE OF AND SHALL NOT BE RESPONSIBLE FOR I ! O CONSTRUCTION MEANS,METHODS,DEVIATIONS,TECHNIQUES,SEQUENCES OR PROCEDURES,OR T-I FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK,FOR THE ACTS OR ' OMMISIONS OF THE CONTRACTOR,SUB-CONTRACTORS,OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK,OR FOR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN ' ! ACCORDANCE WITH THE CONTRACT DOCUMENTS.WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE ! RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS.SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING WITH FABRICATION. '! PROJECT: Alterations Win (3rd ! ! 590 Windward road I ! Orient NY 11957 TABULAR ENERGY ANALYSIS - - "�-------------- 2010 ENERGY CONSERVATION CONSTRUCTI1ON CODE 124'-9" ------- _ __ _ _ SITE PLAN,ZONING ANALYSIS ----�? - ENERGY CODE COMPLIANCE SITE PLAIN (� TO THE BEST OF MY KNOWLEDGE BELIEF AND PROFESSION JUDGEMENT THESE PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH D D NEW YORK STATE 2010 ENERGY CONSERVATION CODE . CHAPTER 3 - CHAPTER 4 . RESIDENTIAL ENERGY EFFICIENCY. SCALE: 1 /1 6"= 1 �-0" NOTES SCALE: AS NOTED RELEASE STATUS OF DRAWING ISUUEDFOR: 101.5.3.1 PROFESSIONAL STATEMENT. AUG 1 7 2016 DATE: ❑ ENERGY ANALYSIS FOR INTERIOR RENOVATION ANY REGISTERED DESIGN PROFESSIONAL OR LEAD ENERGY 03. 1 C. 16 SCHEMATIC DESIGN - CLIMATE ZONE 4 - SUFFOLK ( TABLE 402.1 .1 ) PROFESSIONAL FILING AN APPLICATION OR APPLICATIONS FOR A ❑ DESIGN DEVELOPMENT REFERENCE DETAILS NEW BUILDING OR ALTERATION PROJECT SHALL PROVIDE ON A BUILDING DEPT. DRAWN BY: REY ❑ PROGRESS PRINT NEW YORK STATE 2010 ENERGY CONSERVATION CODE . SIGNED AND SEALED DRAWING A STATEMENT OF COMPLIANCE OR TOWN OF SOUTHOLD ITEM DESCRIPTION PROPOSED DESIGN VALUE CODE PRESCRIPTIVE VALUE CHAPTER 4. EXEMPTION IN ACCORDANCE WITH THE RULES OF THE DEPARTMENT. CHECKED BY: Wf155 ❑ PAIMALREIFASE RESIDENTIAL ENERGY EFFICIENCY. ❑ FULL RELEASE TABLE 402.1 .1 TABLE 303.1 .3(3) TABLE 402.1 .1 JOB No: 57 76 EXISTING ENTRANCE DOOR U-FACTOR:0.35 SHGC:0.70 80 INSULATION AND FENESTRATION REQUIREMENTS MAX. U-FACTOR : 0.35 SHGC: 0.70 BY COMPONENT 403.3 MECHANICAL SYSTEM PIPING INSULATION. REVISION No/DATE: MECHANICAL SYSTEM PIPING CAPABLE OF CARRYING FLUIDS ABOVE 105°F (41°C) OR BELOW 55°F (13°C) SHALL BE INSULATED TO A MINIMUM OF R-3 SEAL&SIGNAT RE - 403.4 CIRCULATING HOT WATER SYSTEMS. -D A ALL CIRCULATING SERVICE HOT WATER PIPING SHALL BE INSULATED TO AT LEAST R-2. CIRCULATING HOT 1aOR WATER SYSTEMS SHALL INCLUDE AN AUTOMATIC OR READILY ACCESSIBLE MANUAL SWITCH THAT CAN �� REQUIRED PIPING FOR MECHANICAL SYSTEM PIPING R-3 MECHANICAL SYSTEM PIPING R-3 403.3 MECHANICAL SYSTEM PIPING INSULATION. TURN OFF THE HOT WATER CIRCULATING PUMP WHEN THE SYSTEM IS NOT IN USE. HOT WATER R-2. CIRCULATING HOT WATER R-2. CIRCULATING HOT WATER 403.4 CIRCULATING HOT WATER SYSTEMS. a SECTION ECC 404 �� r o I DRAWING NO.: ELECTRICAL POWER AND LIGHTING SYSTEMS PROPOSED 50 PERCENT OF THE 404.1 LIGHTING EQUIPMENT (MANDATORY). 404.1 LIGHTING EQUIPMENT (MANDATORY). LAMPS IN PERMANENTLY A MINIMUM OF 50 PERCENT OF THE LAMPS IN SECTION ECC 404 ELECTRICAL POWER AND LIGHTING SYSTEMS A MINIMUM OF 50 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE Vic, . , t LIGHTING INSTALLED LIGHTING FIXTURES PERMANENTLY INSTALLED LIGHTING FIXTURES HIGH-EFFICACY LAMPS. - A - 001 O SHALL BE HIGH-EFFICACY LAMPS. SHALL BE HIGH-EFFICACY LAMPS. 404.1 LIGHTING EQUIPMENT (MANDATORY). NOT VAUDFOR CONSTRUCTION UNLESS SIGNED AND SEALED BY THE ARCHITECT AND APPROVED 1 OF 2 a" 5/8^ 5/8" Basement Floor Plan �C) •= N -3 5/8"METAL STUDS @ 16"O.C.w/(1) >Z 0 ►..rA � LAYER, FC#60,5/8"THK G.W.B.ON CHIMNEY , SI�"i 0i BOTH SIDES,(1)HR FIRE RATED, BSA CAL#301-60 SM .' O r., 3 5/8"METAL STUDS @ 16"O.C. EX. ®FD ONE ' G )FIFMO E/ ' 6 .W.B ° � ..• ra EACH 510E EXISTING BOILER z WALL TYPE - F 1-o EXISTING / F S A N D O R W E I S S , R. A. ROOM coo DOOR SCALE NTS (I) HR RATED BSA CAL #301-60 SM UL:DES U419 1317 AVENUE J, BROOKLYN NY 11230 \ \ FAX(718)692 1914-692-08M NN O.MUNDI.ARCHITE ®GMAILCOM 0 �tiOoti� SCOPE OF WORK : SD/CO �2 EXISTING WINDOW PLUMBING FIXTURE SCHEDULE � II EXISTING SYMBOL AM DESCRIPTION S/W V HW CW WINDOW O SINK i 18 GA.STAINLESS STEEL WITH DRAIN O 1 OR 2 COMPARTMENTS 2" 1 1/2" 1/2" 1/2" SD/CO KITCHEN SINK EXISTING LAV LAVATORY SELF-RIMMING SET IN COUNTER© STORAGE AREA a OPEN DRAINOP WITH CENTER SET& 11/2" 1 1/2" 1/2" 1/2" SD/COEXISTING O �o GARAGE D WC WATER CLOSET FLUSH TANK FLOOR MOUNTED-WHITE,WITH 4" 2" 3/4" OPEN FRONT SOLID PLASTIC SEAT- E VITREOUS CHINA o L• EXISTING TUB BATH TUAST B WITH ENAMEL FINISH 1 1/2 1 1/2" 1/2" 1/2" STORAGE AREA Z w O WM WASHING MACHINE,PROVIDED FI... �g � ❑ BY OWNER.PROVIDE AMERICAN 2" 11/2" 1/2" 1/2" cn57< C STANDARD VACUUM BREAKER SD CO LLjO (MEA#40-70M) EXISTING ODOOR O SD/CO E I Al SD/CO _j I EXISTING EXISTING EXISTING WINDOW WINDOW WINDOW .. r y. �\ S basement floor 1320.54 eq.ft. EXISTING BASEMENT PLAN SCALE: 3/16"=v_0. '-0" Basement Floor Plan CHIMNEY EXI5TIN& �4" SOIL EXISTIN& EX. 5" VENT ®FD 2" " HI M I 1 1�2" 1 1�2" 2 I I 1 ST FL. I EXISTING BASEMENT I i DRYER BOILER 0 EDIOOR dryer / / \ \ ROOM V. 0w VENT// 1 11/2" 1 1 2" 2 I 1 Y2" 4" C.O. 4" EXISTING EXISTING HOUSE SD/CO SEWER GAS LINE THE ARCHITECT SHALL NOT HAVE CONTROL OR CHARGE OF AND SHALL NOT BE RESPONSIBLE FOR i� \ �. • �/ CONSTRUCTION MEANS,METHODS,DEVIATIONS,TECHNIQUES,SEQUENCES OR PROCEDURES,OR EXISTING BASEMENT FL. FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK,FOR THE ACTS OR /, WINDOW PLUMBING RISERS D IAG RAM EXISTING 1 GAS METER OMMISIONS OF THE CONTRACTOR,SUB-CONTRACTORS,OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK,OR FOR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN A B A S E M E N T U F L. ACCORDANCE WITH THE CONTRACT DOCUMENTS.WRITTEN DIMENSIONS ON THIS DRAWING LAUNDRY �` ( I SCALE: N.T.S. SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE r�1N'd RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE ROOM �'O� D NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE GAS RISER DIAGRAM DRAWINGS.SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING ash NY CL. EXISTING WITH FABRICATION, O - WINDOW PLUMBING NOTES PROJECT: SD/CO1. COMPLETE PLUMBING SYSTEM & DRAINAGE SYSTEM INSTALLATION SHALL COMPLY WITH SUB-CHAPTER 16 & RS 16-1. SCALE: N.T.S. Alterations F D1 (;F .J 2. INSTALLATION OF PLUMBING FIXTURES FOR THE HANDICAPPED SHALL 590 Wridward road COMPLY WITH ALL REQUIREMENTS OF LOCAL LAW 58/87. O o C NEW CL (� 3. PROVIDE CLEANOUTS AT BASE OF ALL STACKS. Odent NY 11957 RECREATION AREA 4. PROVIDE SHUT-OFF VALVES ON ALL WATER SUPPLY LINES AT FIXTURES. 5. PURGE ALL WATER AND GAS LINES BEFORE FINAL CONNECTIONS TITLE ATHROOM E 21-4�� 6. PROVIDE AIR CHAMBERS AT TOP OF WATER RISERS MINIMUM 18" HIGH; \ L ®I 1 1/2" DIAMETER. EXISTING PLANS NOTE: SD/CO L 7. STANDARD WEIGHT BLACK STEEL PIPE FOR GAS SYSTEM WITH GALVANIZED CEILING TO BE MIN. (1) HR FIRE RATED. - NEW STEEL FITTINGS. ONE LAYERS, FC #60, 5/8"THK. G.W.B. 3'-0" RECREATION AREA 8. FLOOR DRAINS SHALL BE PROVIDED WITH REMOVABLE STRAINER AS PER RS 16. 9. TRAPS FOR FLOOR DRAINS SHALL BE DEEP SEAL TYPE. �P O 10. APPROVED TYPE WATER METER TO BE INSTALLED TO CONFORM WITH O �\ E IS SD/CO LEGISLATION SIGNED INTO LAW ON JULY 31, 1985. SCALE: AS NOTED RELEASE STATUS OF DRAWING ISUUED FOR: DOOR 11. ALL PIPING INSTALLEDTO SERVICE BUILDING AND WITHIN BUILDING SHALL BE O THERMALLY INSULATED AS PER NEW YORK STATE ENERGY CONSERVATION DATE: 03. I G. I G ❑ SCHEmxxDESIGN SD/CO CONSTRUCTION CODE. ❑ DESIGNDEVELOPMENr E ISI G 12. WATER METERS LOCATED OUTSIDE OF THE BUILDING AND WITHIN THE DRAWN BY: REY ITAIR PROPERTY LINE, SHALL BE INSTALLED IN AN ACCESSIBLE, WATERTIGHT AND ❑ PROGRmPmw FROST PROOF PIT OR METER BOX AS PER SEC. P1 07.3(b). CHECKED BY: We155 ❑ PARTIAL RELEASE 13. PLUMBING VENT LINE TO EXTEND 2-0" MINIMUM ABOVE FINISHED ROOF. 1 ❑ RILL RELEASE 14. INSTALLATION OF WATER SUPPLY SERVICE LINES SHALL COMPLY WITH JOB NO: 5776-M SEC. 19. ROOF GUTTERS SHALL BE AS PER RS 16-19. EXISTING EXISTING EXISTING 15. SEPARATION OF WATER SUPPLY SERVICE AND BUILDING SEWER SHALL COMPLY REVISION No/DATE: WINDOW WINDOW WINDOW WITH SEC. P1 07.2(b) (6). 16. PROTECTIVE COVER FOR SERVICE PIPE SHALL COMPLY WITH SEC. P1 07.2(b) (6). SEAL&SIGNATURE 17. WATER METER LOCATION SHALL BE SUBJECT TO APPROVAL BY THE DEPARTMENT OF WATER SUPPLY, GAS AND ELECTRICITY, AND SHALL COMPLY ��F c D AR . WITH SEC. P1 07.2(b) (6). O\5 • 4�OI` �i� 18. PRIOR TO THE INSTALLATION OF HOUSE DRAIN, PLUMBING CONTRACTOR SHALL 41 CHECH AND VERIFY DEPTH OF SEWER/SEWERS IN STREET TO ASCERTAIN THE , L `" BASEMENT PLAN ;W S basement floor 1320.54 sq.ft. COMPLIANCE OF PROVIDING THE MINIMUM REQUIRED PITCH OF HOUSE SEWER, AS PER l BUILDING CODE REQUIREMENTS. ANY DISCREPANCIES SHALL BE REPORTED TO SCALE: 3/16"=1 -O" ARCHITECT IMMEDIATELY PRIOR TO THE START OF ANY WORK. �' `sF � r DRAWING NO.: 19. ROOF GUTTERS SHALL BE AS PER RS 16-19. 20. PLUMBING CONTRACTOR SHALL VERIFY ALL INVERTS AND EXISTING CONDITIONS "F NE",�,,I (O PRIOR TO THE INSTALLATION OF NEW WORK. A - 21. ALL HOT AND COLD WATER LINES TO BE INSULATED WITH VACUUM BREAKERS. 002mOO NOT VALID FOR CONSTRUCTION UNLESS SIGNED AND SEALED BY THE ARCHITECT AND APPROVED 2 OF 2 4" GRU5HED 5TONE Second Floor Plan VAPOR BARRIER #4 NOSING (TYP. PITCH I/8"/ FT 00 �� p ... w I* �z N a^ 3500# o �' D� (T s/s^ • z d�0 s/s^ s/s^ EXT. GONG. • � � B '>� o �.,^. ,•,, EXISTINGF1 CHIMNEY O i filo�j� ° • ° Y25 D ° n o�0i 3 5/8"METAL STUDS @ 16"O.C.W/(1) LAYER,FC#60,5/8"THK G.W.B.ON _ BOTH SIDES,(1)HR FIRE RATED, #4 @ 12" O.G. / �y74" `t/S� �Q^ BSA CAL#301-60 SM D 'I/Q1 ".9� �� 3 5/8'METAL STUDS @ 16"O.C. D / EXISTING �O ° BEDR OM O S A N D O R W E I S S , R. A. M. Q ti� ONE (l) LAYER5 sib" #4 @ 12" O.G., TYP. \ 6.W.8.FIREGODE •c• ° o° 1317 AVENUE J, BROOKLYN NY 11230 / SD/CQ o P / EACH 51DE D ° o (718)692-0800-(718)692-0898 FAX(718)692-1914-ANNO.MUNDLARCHI ECTOGMAILCOM / ooh ooti� . F WALLWK - F SCOPE OF WORK : XIS 9CA E NTS ll) HR RATED (3) #4 REBA o D D EXISTING ; o ` , BSA CAL #301-60 SM UL:DES U419 TYP. ° o ° D ° . ° p PLUMBING FIXTURE SCHEDULE / BATHROOM EDIOOR I ���P DST` p •� .° • • • • o ti� �\oP o oo � EXISTING CONCRETE STAIR DETAIL "�OL ABBIR ° ��1ON S'W �"' / EX• \ - - - - - - - - - - - - - - - - - - - SINK 18 GA.STAINLESS STEEL WITH DRAIN / BEDROOM / - > O 1 OR 2 COMPARTMENTS 2" 1 1/2" 1/2" 1/2" CL. o / OSD/CO / SCALE: N.T.S. ` / KITCHEN SINK o EX. Cn o / Exls I / 1 LAV LAVATORY SELF-RIMMING SET IN CL. z� O / / FLUSH OPEN ERAIN P WITH CENTER SET& 1 1/2' 1 1/2" 1/2" 1/2" w 0 / TRANSITION XIS EXISTING / / / 1/2" RADIUS WC WATER CLOSET FLUSH TANK OR BEDROOM ' _ _ _ HANDRAIL _\, FLOOR NFRMOUNTED TSOLI PLASTIC CSEWITH 4° 2° 3/4" S � - � VOTTREOUS CH VALID PLASTIC SEAT- - - - - - - - - - - - - - - - - 00 �� O S D/CO O SD/CO / I TRIM TYP. = TUB CAST IRON WITH ENAMEL FINISH BALUSTER TREAD BATHTUB 11/2' 11/2" 1/2" 1/2" EkISTING J WOOD BLOCK �° ` � � \ / � WM WASHING MACHINE,PROVIDED O P \EXISTIN / VOLUTE CUT TO FIT I ❑ BY OWNER.PROVIDE AMERICAN 2' 1 1/2' 1/2" 1/2" I TING 100 - - - - - - - - - - STANDARD VACUUM BREAKER BA �O ��\ _ OPEI\f TO LAW ADAAG (MEA#40-70M) NEWEL ACCEPTABLE P I EX. i BASE AT WALL NOSING SHO SHOWER WITH PRECAST RECEPTOR � � I � I 2" 1112" 1/2" 1/2" � \ oo C L. POST � \ I � I d /I� WOOD FINISH FLOORING �\��j AS I G S Al EXISTING WINDOW \ X. oP EXISTING CL BEDROOM PLYWOOD SUBFLOOR NOTES SD/CO \ I AT TREAD AND RISER I HAVE IDENTIFIED HEREIN ALL OF THE PROGRESS INSPECTIONS, � � O / / I I AND COMMISSIONING REQUIRED FOR COMPLIANCE AND FULL DETERMINED L/ - - - - - _ - - - - STRINGER THAT THIS PROJECT DOES NOT REQUIRE COMMISSIONING. NOTCHED STRINGER NOTES ACCESS OPENINGS FROM CONDITIONED SPACE TO SHAFTS, CHUTES S 2nd floor 1340.12 sq.fL STAIRWAYS AND ELEVATOR LOBBIES SHALL MEET C402.4.3 OR BE GASKETED, WEATHERSTRIPPED, OR SEALED. SOFFIT EXISTING SECOND FLOOR PLAN FIRE BLOCKING SCALE: 3/16"=1'-0" CARRIAGE NO WORK @ 2ND FL. \ PLUMBING NOTES 1. COMPLETE PLUMBING SYSTEM & DRAINAGE SYSTEM INSTALLATION OPEN STRINGER/ SHALL COMPLY WITH SUB-CHAPTER 16 &RS 16-1. OPEN RAIL 2. INSTALLATION OF PLUMBING FIXTURES FOR THE HANDICAPPED SHALL COMPLY WITH ALL REQUIREMENTS OF LOCAL LAW 58/87. 3. PROVIDE CLEANOUTS AT BASE OF ALL STACKS. ELEVATION SECTION 4. PROVIDE SHUT-OFF VALVES ON ALL WATER SUPPLY LINES AT FIXTURES. 5. PURGE ALL WATER AND GAS LINES BEFORE FINAL CONNECTIONS 6. PROVIDE AIR CHAMBERS AT TOP OF WATER RISERS MINIMUM 18" HIGH; 0WOOD STAIR DETAIL 1 1/2" DIAMETER. 7. STANDARD WEIGHT BLACK STEEL PIPE FOR GAS SYSTEM WITH GALVANIZED STEEL FITTINGS. SCALE' N.T.S. 8. FLOOR DRAINS SHALL BE PROVIDED WITH REMOVABLE STRAINER AS PER RS 16. 9. TRAPS FOR FLOOR DRAINS SHALL BE DEEP SEAL TYPE. EXISTING 10. APPROVED TYPE WATER METER TO BE INSTALLED TO CONFORM WITH 4" SOIL LEGISLATION SIGNED INTO LAW ON JULY 31, 1985. EXISTING DRYER 11. ALL PIPING INSTALLEDTO SERVICE BUILDING AND WITHIN BUILDING SHALL BE " ___ _ 3" VENT " THE ARCHITECT HALL T HAVE CONTROL R CHARGE OF AND SHALL NOT BE RESPONSIBLE FOR _ _ CONSTRUCTION MEANS,METHODS,DEVIATIONS,TECHNIQUES,SEQUENCES OR PROCEDURES,OR THERMALLY INSULATED AS PER NEW YORK STATE ENERGY CONSERVATION �'-T---I y I I r T -I--"T--�-- T--, 3/32" VINYL TILE OR APP'D FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK,FOR THE ACTS OR r r EQUAL 5/8" PLYWOOD SUBFLOOR (TYP.) OMMISIONS OF THE CONTRACTOR,SUB-CONTRACTORS,OR ANY OTHER PERSONS PERFORMING CONSTRUCTION CODE. W M I 1 1�2" 1 112" j2 ( 1 2 1 1 1�2" 1 2 1 1 1�`" 1 /2" 1 W M 12. WATER METERS LOCATED OUTSIDE OF THE BUILDING AND WITHIN THE I i I I I IANY OF PROPERTY LINE, SHALL BE INSTALLED IN AN ACCESSIBLE, WATERTIGHT AND M01 1ST FL. ANY ORDANCEWTTHT RTHE NTRA TDOC DOCUMENTS. EM TO CARRY OUT WORK IN 1/2 HARDWOOD FLOOR ACCORDANCE WITH THE CONTRACT DOCUMENTS.WRITTEN DIMENSIONS ON THIS DRAWING FROST PROOF PIT OR METER BOX AS PER ;SEC. P1 07.3(b). OIL ) FIRST FLOOR I 1/4` MONSANTO SILENT OOD FINISH FLOOR SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE 13. PLUMBING VENT LINE TO EXTEND 2'-0" MINIMUM ABOVE FINISHED ROOF. CORPOLYSTYRENE DW 14. INSTALLATION OF WATER SUPPLY SERVICE LINES SHALL COMPLY WITH 1 11/2" 1 1 2" 2" I 2" 1 /2" 2" 1 /2" DRYER UNDERLAYMENT RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS.SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING " 4" 4" C.O. 1 " WffH FABRICATION. SEC. 19. ROOF GUTTERS SHALL BE AS PER RS 16-19. 4 C.O. " I Y 15. SEPARATION OF WATER SUPPLY SERVICE SAND BUILDING SEWER SHALL COMPLY -1---12" I -I WITH SEC. P1 07.2(b) (6). r r- 12" 1 I PROJECT: Alterations 16. PROTECTIVE COVER FOR SERVICE PIPE SHALL COMPLY WITH SEC. P1 07.2(b) (6). WMI 1 1�2" 111,2- I I i EXISTING 17. WATER METER LOCATION SHALL BE SUBJECT TO APPROVAL BY THE o I I I GAS UNE WOOD JOISTS 590 Windward road DEPARTMENT OF WATER SUPPLY, GAS AND ELECTRICITY, AND SHALL COMPLY OILBASEMENT I 3x10016 O.C. WITH SEC. P1 07.2(b) (6). - - - - BASEMENT FL. _ _ Orlent NY 11957 18. PRIOR TO THE INSTALLATION OF HOUSE DRAIN, PLUMBING CONTRACTOR SHALL 1 11/2" 1 1k2- 2" ( EXISTING I GAS METER CHECH AND VERIFY DEPTH OF SEWER/SEWERS IN STREET, TO ASCERTAIN THE 4" C.O. 4" AT BASEMENTU FL, 5/8" FLAMEBOARD 1/2" RESILIENT CHANNEL CUPS COMPLIANCE OF PROVIDING THE MINIMUM REQUIRED PITCH OF HOUSE SEWER, AS PER BUILDING CODE REQUIREMENTS. ANY DISCREPANCIES SHALL BE REPORTED TO EXISTING PLASTERBOARD TYPE "X" - 24"O.C. TITLE: HOUSE ARCHITECT IMMEDIATELY PRIOR TO THE START OF ANY WORK. 19. ROOF GUTTERS SHALL BE AS PER RS 16-19. SEWER WOOD FLOOR DETAIL EXISTINGFLOOR PLAN 20. PLUMBING CONTRACTOR SHALL VERIFY ALL INVERTS AND EXISTING CONDITIONS [, /� R/� � /� GAS RISER DIAGRAM PRIOR TO THE INSTALLATION OF NEW WORK. PLUMBING RISERS DIAGRAM SCALE: 21. ALL HOT AND COLD WATER LINES TO BE INSULATED WITH VACUUM BREAKERS. SCALE: N.T.S. SCALE: N.T.S. SCALE: AS NOTED RELEASE STATUS OF DRAWING ISUUED FOR: DATE: FEB. 2015 ❑ SCHEMATIC DESIGN DRAWN BY: KEY ❑ DEsr.N DEVELOPMENT ❑ PROGRESS PRINT CHECKED BY: WCI55 ❑ PARTIAL RELEASE DOOR SCHEDULE ANDERSEN ❑ RILL RELEASE NOTES JOB No: 5775-020 PROPOSED FENESTRATION REQUIREMENTS FENESTRATION TABLE C402.4.3 -ALL WINDOWS TO MEET MINIMUM REQUIREMENTS REVISION No/DATE: TABLE C402.3 TABLE C402.3 TABLE C402.3 TABLE C402.3 PROPOSED MAXIMUM OF THE NYS ENERGY CODE& CONSERVATION NO. WIDTH HEIGHT ROOM NAME TYPE ARE R MATERIAL SADDLE NOTES U-FACTOR SHGC U-FACTOR SHGC AIR INFILTRATION AIR INFILTRATION CODE. SEAL­&.SIGNATURE,, A (2)3'-0" 7'-0" ENTRANCE 1 NONE H/NTL - PR. PANIC HARDWARE,FRONT U-FACTOR:0.29 SHGC:0.32 U-FACTOR:0.77 SHGC:0. 2 40 0.2 CFM/FT 0.2 CFM/FT2 �� �� -ALL WINDOWS MANUF. BY ANDERSEN WINDOW ,, -v U-FACTOR:0.29 SHGC:0.32 U-FACTOR:0.77 SHGC:0.40 0.2 CFM/FT2 0.2 CFM/FT2 UNLESS OTHERWISE NOTED. / n F1 (4)2'-3" 6'-8" RECREATION AREA 2 NONE H/NTL - p ' -ALL WINDOWS TO BE EQUIPPED WITH WINDOW B 2'-8" 6'-8" BEDROOM 3 NONE WD - - -� C 2'-0" 6'-8" BATHROOM 3 NONE WD MARBLE 1 UNDER CUT SCREENS, DOUBLE GLAZED, &50% MIN. OPENABLE. a -COLOR AS PER OWNER'S SELECTION. D 2 -0 61-811 CLOSET 3 NONE WD L ��T pM1!'� DRAWING NO.. f D1 (2) 2'-0" 6'-8" CLOSET DOUBLE 4 NONE WD -IF 2 2'-6" 6'-11" BALCONY 5 NONE I AL/GL I - I 003u00 NOT VALID FOR CONSTRUCTION UNLESS SIGNED AND SEALED BY THE ARCHITECT AND APPROVED 3 OF 5 BY THE DEPARTMENT OF BUILDINGS First Floor Plan (Reconstruction) � o "22A .�,,� �z N \C7 0 C1 ton Cp— SANDOR WEISS , R. A. SD/CO ootid, 1317 AVENUE J, BROOKLYN NY 11230 , EXISTING \ PORCH (718)692-0800-(718)692-0898 9'' READING ROOM FAX(118)692-1914-ANNO.MUNDI.ARCHIiECTOGMAILCOM \ \\ AREA=605.0 S.F. SCOPE OF WORK : \\ V.R.=30.25 S.F. \ V.O.=55.0 S.F. ,<i EXISTING EXISTING EXISTING OEXISTING oo9ti� WINDOW WINDOW WINDOW LIVING - - - dw NOTE: \ ROOM 14'-9" VEN CEILING TO BE MIN. (1) HR IoF FIRE RATED. O� S' \\ ONE LAYERS, FC#60, 5/8" h' �;,� �,j � +4.5 EXISTING EXISTING \\ \v G G.W.B. SO O _ DINING ROOM O \ CL. si h TNG DOOR "O , O x dryer i� \ F � '' � SD/CO z� 14 -011 \ �washer'> - / o v 10 L�i D O F BA''fHROO -z ISTING ooR LI EXISTING BA ROO EXISTING RECREATION AREAi _ FAMILY O //„'1' 10' 4" ROOM SD/CO < G) EXISTING o ?: CL. HALL ^\ + + NoO SD/CO zO °EX.0.0" >9, F 0, O CL. s /c0 EXISTING �y AA KITCHEN + + O O EXISTIr JG T I 'r9, S D/CO O F BEDROOM z #1 AREA=101.2 S.F. V.R.=5.0 S.F. ° V.O.=12.5 S.F. Q EXISTING EXISTING O "O EXISTING A _ WINDOW WINDOW WINDOW - �� 5 O x y joh� FIRST FLOOR PLAN SCALE: 3/16"=V-0" '-0" Basement Floor Plan CHIMNEY EX. ®FD EXISTING BOILER EXIS ROOM DOOR - THE ARCHITECT SHALL NOT HAVE CONTROL OR CHARGE OF AND SHALL NOT BE RESPONSIBLE FOR SD/CO j CONSTRUCTION MEANS,METHODS,DEVIATIONS,TECHNIQUES,SEQUENCES OR PROCEDURES,OR EXISTING FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK,FOR THE ACTS OR WINDOW OMMISIONS OF THE CONTRACTOR,SUB-CONTRACTORS,OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK,OR FOR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN LAUNDRY I I ACCORDANCE WITH THE CONTRACT DOCUMENTS.WRITTEN DIMENSIONS ON THIS DRAWING ROOM SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE o I I RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE ..� D NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE C L. DRAWINGS.SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING EXISTING WITH FABRICATION. WINDOW O _ I PROJECT: SD/CO F Alterations I IF "' D1 _ 0 590 Windward road D CL. ' Orient NY 11957 0- EXISTING ATHROOM RECREATION AREA TITLE 21411 Kms' E L. SD/CO OO - i PROPOSED PLAN NOTE: EXISTING CEILING TO BE MIN. (1) HR FIRE RATED. ONE LAYERS, FC#60, 5/8"THK. G.W.B. 3'-0" RECREATION AREA ` P NOT TO BE USED FOR SCALE: AS NOTED RELEASE STATUS OF DRAWING ISUUED FOR: SLEEPING, COOKING, S D/CO OR LIVING 0 ® DATE: FEB. 2015 ❑ SCHEMATIC DESIGN I DRAWN BY: KEY SD/CO El DESIGN DEVELOPMENT T I El PROGRESS PRINT Is T CHECKED BY: Wells ❑ PARMLRELEASE ❑ FULL RELEASE JOB No: 5775.020 EXISTING EXISTING EXISTING REVISION No/DATE: WINDOW WINDOW WINDOW - SEAL &SIGNATURE / f BASEMENT PLAN S basement floor Q7- t 'q 3 16"=1/ SCALE. -011 DRAWING NO.: arras: 004 , 00 NOT VALID FOR CONSTRUCTION UNLESS SIGNED AND SEALED BY THE ARCHITECT AND APPROVED 4 OF 5 BY THE DEPARTMENT OF BUILDINGS A"X7" PLATE (BOTH ` SIDES) W/16— EXIST. 8"(V.I.F.) THRU BOLTS • N a'•qp p First Floor Plan WOOD BE AM— Basement Floor Plan TYP. I �` a Z- 0 (Reconstruction) 3 �, 0> ° ZONO -ZA 00 EXIST. PIPE I 1"X7" PLATE (BOTH " NEW 3 DIA. PIPE POST 16 a T-= \ II REMOVED II W 4 TOP & BOTT. PLATES SIDES) W/16— � T I II &4— " ANCHORD BOLTS THRU BOLTS N 8" EMBEDMENT IN CONCRETE S A N D O R W E I S S , R. A. I I 1317 AVENUE J, BROOKLYN NY 11230 I I (718)692-0800-(718)692-0898 4 5-8"EMBEDM. FAX(718)692-1914-ANNO.MUNDI.ARCHITECTOGMAILCOM IS NCRETE II SCOPE OF WORK : \ �� TYP EXIST. CONCRETE ( I 4— 5-8"EMBEDM. WOOD BEAM FOOTING SECTIO O� \ IN EXIST. CONCRETE 2X6 \ LJ TYP STUD G� \ NEW PART ELEVATION— +4'-6" OF FOOTING 2X10 EXISTING POST P EXISTING TP OBE REMOVED 1 0^ 4024" O/C Q; o 2x10@16" joist x \ ,y%` \ �'`,:\ f '" 8"C.M.U. WALL ' C.M.U. WAL << & / . ' o \ % SECTION 1 - 1 EXISTING 8"WOOD BEA (V.I.F.)TO BE REINFORCETS \ ` 12x10" CONCRETE TYP �\ \ NEW 3 J"DIA. PIPE FOOTING POST W/ J" TOP & i BOTT. PLATES & 4— " ANCHORD BOLTS \ TYP 0.0" a SECTION B—B FOUNDATION PLAN FRIST FLOOR PLAN SCALE: 3%16° = V-0" SCALE: 3/16" = 1'-0" THE ARCHITECT SHALL NOT HAVE CONTROL OR CHARGE OF AND SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS,METHODS,DEVIATIONS,TECHNIQUES,SEQUENCES OR PROCEDURES,OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK,FOR THE ACTS OR OMMISIONS OF THE CONTRACTOR,SUB—CONTRACTORS,OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK,OR FOR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS.SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING WITH FABRICATION. PROJECT: Alterations 590 Windward road Orlent NY 11957 TITLE : DETAILS SCALE: AS NOTED RELEASE STATUS OF DRAWING ISUUED FOR: DATE: 03.. 1 G. I G ❑ SCHEMATIC DESIGN DRAWN BY: RLI ❑ DESIGN DEVELOPMENT ❑ PROGRESS PRINT CHECKED BY: We155 ❑ PARTIALRELEASE ❑ FULL RELEASE JOB No: 5776.050 REVISION No/DATE: SEAL &SIGNATURE Ll * a r " DRAWING NO.. 005 , 00 NOT VAUD FOR CONSTRUCTION UNLESS SIGNED AND SEALED BY THE ARCHITECT AND APPROVED 5 OF 5 BY THE DEPARTMENT OF BUILDINGS