Loading...
HomeMy WebLinkAbout39095-Z �o�SaFFn1,�cpGy Town of Southold 9/1/2016 a P.O.Box 1179 o • 53095 Main Rd y'yol �0�, Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38491 Date: 9/1/2016 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 28100 Route 25,Orient SCTM#: 473889 Sec/Block/Lot: 18.-6-22.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/11/2014 pursuant to which Building Permit No. 39095 dated 8/11/2014 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: SOLAR HOT WATER SYSTEM IN AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Smith,Andrew&Smith,Jennifer of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED Authorized Signature �S�FFnc�c TOWN OF SOUTHOLD ago ®may BUILDING DEPARTMENT TOWN CLERK'S OFFICE co o . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 39095 Date: 8/11/2014 Permission is hereby granted to: Smith, Andrew & Smith, Jennifer 26 Lefurgy Ave Hastings-on-Hudson, NY 10706 To: install a Solar Hot Water System to an existing dwelling as applied for. Replaces BP# 36739 At premises located at: 28100 Route 25,Orient SCTM # 473889 Sec/Block/Lot# 18.-6-22.1 Pursuant to application dated 8/11/2014 and approved by the Building Inspector. To expire on 2/10/2016. Fees: ELECTRIC $100.00 PERMIT RENEWAL $50.00 Total: $150.00 Building Inspector SOF of c TOWN OF SOUTHOLD �p.A ooy BUILDING DEPARTMENT TOWN CLERK'S OFFICE o . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLAINS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 36739 Date: 10/7/2011 . Permission is hereby granted to: Smith, Andrew & Smith, Jennifer 26 Lefurgy Ave Hastings-on-Hudson, NY 10706 To: install a Solar Hot Water System to an existing dowelling as applied for At premises located at: 28100 Route 25, Orient SCTM # 473889 Sec/Block/Lot# 18.-6-22.1 Pursuant to application dated 9/19/2011 and approved by the Building Inspector._ To expire on 4/7/2013. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $200.00 CO -ADDITION TO DWELLING $50.00 Total: $250.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 Date. New Construction: Old or Pre-existing Building: (check one) in Location of Property: a2 1D0 1 )b &A 3n D(2 (t f\zi— House No. Street Hamlet Owner or Owners of Property: � + Suffolk County Tax Map No 1000, Section VE Block Lot Subdivision Filed Map. Lot: Permit No. � Dq �5—Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ Applicant Signature SOUIy®l � o Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 , ® roger.riche rt(d-)town.southoId.ny.us Southold,NY 11971-0959 Q lyC®UNTY,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Andrew Smith Address: 28100 Route 25 City: Orient St: New York Zip: 11957 Building Permit#: 39095 Section: 18 Block: 6 Lot: 22.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA: Eastern Energy License No: 52689-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water solar GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: Supply Electric to Components of Solar Domestic Hot Water System Notes: Inspector Signature: Date: August 16, 2016 OOElectncal 81 Compliance Form.xls Town Hall Annex i�, Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 CmU , ��_ BUILDING DEPARTMENT+ ' D CC[Eg"[E D TOWN OF SOUTHOLD AUG 4 9 2016 $UII.D�NG DEPT. TOWN OF SOUTHOLD ,,CE1tTIFICA-T-IO-N Date: Building Permit No. tt+,5q 39 o 9 5 Owner• 'Y)da"W ISM�' �h - (Please print) Plumber:_S �G�Vy��-2 MlV�'Wt C�__-- (Please print) I certify that the solder used in the water supply system contains Iess than 2/10 of I% lead. (Plumbers Signature) Sworn to before me this day of 96 , 20 / PATRICIA A MAY �� � — NOTARY PUBLIC-STATE OF NEW YORK No. Ol MA4676634 Qualified in Suffolk County Notary Public, My Commission Expires March 30, 2018 _� County, LUIGI CLAUDIO SCIANDF�A, P.E. 5 Wesleyan Court• Smithtown, NY 11787-3011 • (631)543-2953 •fax(631)543-1526 Cell 631-747-7495 E-mail:Ics4d0_aol.com Sunday, July 31, 2016 D Town of Southold D Building Department Town Hall Annex Building AUG m 9 2016 54375 Route 25 P. O. Box 1179 BUILDING DEPT. Southold, New York 11971 TOWN OF SOUTHOLD Re: Certification Letter—Advanced Thermal Solar,ATS-30, 160 psi, Maximum Allowable Working Pressure, 4750, Maximum Stagnation Temperature, Solar Water Heater Installation,for Smith Residence—28100 Route 25, Orient, New York 11957 1 have reviewed the solar hot water energy system installation in the subject topic on 07/25/201,6:;The;units have been installed in accordance with the manufacturer's installation instructions andtre construction documents approved by the Building Department of the Town of Southold. The solar hot water panel installation is in compliance with the requirements of the 2010 Residential Code of New York State and ASCE-05. To my best belief and,knowledge, the work in this document is accurate, conforms to the governing codes and standards applicable at the time of submission and conforms with reasonable standards of practice with the view to the safeguarding of life, health, property and public welfare. Sincerely, OF NEW yo y�P p.SCIA R� 060935 AROEESS10 -Luigi Claudio Sciandra, Professional Engineer. FIELD Il!T$ MQ19 HIM—T DATE CCNflV�1�tTS. o ' FOUNP417ON(IST) FOUNDATION(2ND)• � z PIOUG$FRAmr,& s PLUMBING '-� INSULATION Pzk STATE 3&EMRGY CODE FINAL ADDITIONAL C+UTS IC ICA LPI m 4Z` °z TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502Survey SoutholdTown.NorthFork.net PERMIT NO. P(Ul.005 &0(f Check 4,OR35 Septic Form 2p N.Y.S.D.E.C. Trustees Flood Permit Examined ,20 Storm-Water Assessment Form Contact: Approved )(011,20 Mail to: Disapproved a/c Phone: Expiration 120 1,2> Building Inspector APPLICATION FOR BUILDING PERMIT Date_Atvn�js* a L� , 20 11 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. I ' APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zoiie Ordinance of the Town of Southold, Suffolk-County,New York, and other applicable L-aws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. I%�4e-rn (Signature of applicant or name,if a corporation) —H710 Scuna Ayt^uL, A"'i4vA , Af Ims%a (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder A��e nt AName of owner of premises A n d re-,-/ S M (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. 13 $199 -H Plumbers License No. Electricians License No. Ai Other Trade's License No. 1. Location of land on which proposed work'will be done: ag►Do M..", baa. ' Or-.er.t House Number Street Hamlet County Tax Map No. 1000 .Section 1 Block 0(®-- Lot' 22.1 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy l'�n•.;l Qts.d en�e b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition. Other Workm^s+,J1A;aA of Salr Not-war Sys4w, (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO 13. Will lot be re-graded?YES NO Will excess fill be removed from premises?YES NO 14.Names of Owner of premises Qnarew Sr 444 . Address Phone No. Name of Architect Address Phone No Name of Contractor 5,,s` am Envoy Sx�" ,Zft. Address 400 saga A,—,,c Phone No. I-61 1-449-1/00y ffi0K+U&, my U9S'ZI 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO ✓ * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet,of a tidal wetland? * YES NO ✓ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO ✓ * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Sn��.K, ) 4r: Pe e-rs0 n being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the !t qe^+— (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowled e and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of 20 Notary Public Signature of A licant BARBARA-H. TAN Y Notary Public, State Of New York No. 01 TA6086001 Qualified In Suffolk County Commission Expires 01/13/20 1 S D AUG - 9 2016 I so BUILDING DEPT Town Hall Annex 9 ( Telephon9("7 0PUMOLD 54375 Main Road y m�a P.O.Box 1179 _ Q roger.richertd-foxw(n.b81)SOUthOi�.nV US Southold,NY 11971-0959 �� �� ,,�„Y BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FORiELECTRICAL INSPECTION I , REQUESTED BY: L.I"SCA Gr�a1'Yl a ra Date: Company Name: PFaS+fn E--ntY S n Name: U!m l I Y1 L ; License No.: 5Z-bP A M ' Address: —40 'SOLAY101 kf - �u d R5 Phone No.. (Q3 L�oDG� JOBSITE INFORMATION: (*Indicates required information) r *Name: G'I��Vy SYYI 1� i *Address: drJ' Yb+ + NY l a5 *Cross Street: a!' *Phone No_. I 641 — .2-1 1 bg Permit No.. Tax-Map District: 1000 Section: Block: Co Lot: *BRIEF DESCRIPTION OF WORK(Please Print Clearly) fy164a 11 (Please Circle All That Apply) *Is job ready for inspection: ` ES/ O Rough in Final *Do•you need a Temp Certificate: �,f 0 O Temp Information(if needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground • Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION I, { 82-Request for Inspection Form T 3 �, f' ® Eastern Energy Systems Inc. The power of independence. Eastern Energy Systems Inc. 7470 Sound Ave Mattituck,NY 11952 Office: (631),779-4004 Attention: �J ;/��'��- � jo� Date: Fa**o: # of Pages: Fax From: (631) 466-5200 Message: A J41 AM/ (. "ad vw ° 04W 1 7 if A6 "DISCLAIMER:This communication,along with any documents,files or attachments,is intended only for the use of the _ addressee and contains privileged and confidential information.If you are not the intended recipient,you are hereby notified that any dissemination,distribution or copying of any information contained in or attached to this communication is strictly prohibited.If you have received this message in error,notify the sender immediately by email reply and destroy the original communication and its attachments without reading,printing or saving in any manner. Southold Town Building Department gUFF�j,�c P.O.Box 1179 Permit#: 36739 Co 54375 Main Road Southold,New York 11971 Permit Date: 10/7/2011 (631)765-1802 Expiration Date: 4/7/2013 Parcel ID: 18.-6-22.1 BUILDING PERMIT RENEWAL LETTER Dated: 7/24/2014 Applicant: Eastern Energy Systems Location: 28100 Route 25, Orient Work Description: OTHER install a Solar Hot Water System to an existing dwelling as applied for A FEE OF $150.00 IS REQUIRED TO RENEW THIS BUILDING PERMIT. Owner: Smith, Andrew& Smith, Jennifer Address: 26 Lefurgy Ave Hastings-on-Hudson,NY 10706 The permit listed above has expired. No work is permitted or authorized beyond the expiration date. Please submit the above fee made payable to the Town of Southold. Mail to the Town of Southold Building Department, P.O. Box 1179, Southold, New York 11971 THANK YOU, SOUTHOLD TOWN BUILDING DEPT. 010HAOS d0 IN01 1d30 SM ti�oz a— env July 29, 2014 Southhold Town Building Department P.O. Box 1179 54375 Main Road Southold,NY 11971 Dear Building Department: Per your request, enclosed is $150 for renewal of our Building Permit#36739, at 28100 Route 25, Orient,NY. The project has been completed and is ready for inspection to close out the permit. Please feel free to reach out to me at 212-455-7939 or by e-mail at asmithgstblaw.com to schedule an inspection at your convenience. Thank you. Best regards, /Pvsc f_� Andrew Smith 26 Lefurgy Avenue Hastings-on-Hudson,NY 10706 Enclosures 08-31-11 ; 14:27 4665200 # 1/ 1 SURVEY OF PROPERTY N AT ORIENT TOWN OF SO UT,HOLD SUFFOLK COUNTY, N.Y. 1000-18-06-22.1 SCALE.. 1=-30' + SEP7EMBER 21, 2010 rn gOAD x,50 „' d �A MT -.!'` 16a0 13313.92W'OR pDAD WHALT N \ � n • 209• IPA K Q . e� CER77RED TO. Gib ANDREW SMITH JENNIFER SMITH FIRST AMERICAN 77XE INSURANCE COMPANY a1 . C171MOR?tAGE, dNC., ITS SUCCESSORS OR ASSIGNS I�r AREA!539,773 SO. FT. ■mM0N1/MENT •• .P1PE1 6f8 gNY'AUER ?M OR ADDmoN TD 7MS SURVEY IS A YlOLAnON CONK OR , OF sECnON 7209OF M ALrW YORK STATE EOUCATFON LAIC (631) 765-5020 FAX sfi-1797 Dr&rAs PER sECAON 7209-su WK90N 2•ALLY.CERFRCATIONS P.O. BOX 909 HEIF R"OER yA60P/E8 BEAR THE IMI'RES$kD SEAL',Of TFtEOFESLNtVEYDR 1230 '7RAVEL£R STREET q lWO-IlE SGNAn ftr APPEARS, JaV. sOUrnOLO, N.Y. 11971 l 0-210 i OCT-07-2011 15:15 From:MERYL ,KRAMER ARCh 6314778936 To:7659502 Pa9e:1/1 M E R Y E K R A M IE R a r c h j t e c t t Ms.Patricia Conklin Southold Town Building Dept. Southold Town Hall PO Box 1179 Southold.NY 11971 October 6,2011 RE: Smith Residence Tax Map#1000-18.06.22.1 Dear Pat, The roof structure of the above mentioned residence meets the standards of the New York State Building Code with the solar hot water panels and all associated mounting hardware and equipment. Please let me know if you require further documentation regarding this permit application. Best Regards, jMerVylertA[A:LEEDAP Cc: Andrew and Jennifer Smith East End Energy Systems __ _ _ .. .. ,.,... ,---T niv Benne C2S_A77_072C WWW uu&P `NITFf`T f'.OM 37•� i s Evacuated tube specifications Material High Quality Borosilicate Glass 3.3 Glass(Outer) Tube Diameter 2.28"(58 mm) Glass(Inner)Tube Diameter 1.85"(48 mm) Wall thickness 0.06" (1.6 mm) Length 5.9 ft(I800mm) Single Tube Weight 6 lb (2.2kg) Vacuum Pressure <3.5 x10-3 mPa—Maintained with a Barium getter in each tube Absorbance of Solar Selective Absorptive Coating >92% Selective Absorptive Coating AL-N-AL i Impact Resistance Steel Ball test: Steel ball with a diameter of 1"dropped on the tube vertically from 18 height with no damage Manifold and frame Header casing material Aircraft Aluminum 6061 Frame material #304 Stainless Steel Tie Bar Aircraft Aluminum 6061 Manifold Insulation R7 Compressed Rock Wool Internal Manifold Copper brazed with lead free 45%-silver solder. Manifold Port Size %"Copper Tube at each end 3 50 Aero Road Bohemia, NY 116716 USA 9 Phone-. iii 655.9349 • 961.8,815 Collector specifications Number of Tubes 10 22 30 Aperture Area (SF)/Gross Area(SF) 10.7/17.3 19.4/41.3 26.4/55.1 Collector contents(Gal) 0.2 0.4 0.5 Assembled panel weight(Lbs) 80 180 240 Max Pressure(psi) 160 Max Stagnation Temp(F) 4750F Y Intercept -0.352 Btu/hr-ftp°F Hot Water Output A+80°F Sunlight @ 17 MJ/m2 23.78 gal 52.83 gal 71.33 gal (Gal/Day/Collector) Cold weather application -31°F Suggested Flow rate =0.03 Gal/Min/Tube 4 ,Advanced Thermal SolarmrJlUnfted Solar Supply :• • •• •m -www.adAhermalsolar.com 50 • R•.• Bohemia, • USA aPhone: sii • • • 96 1,8815 COPPER HEAT PIPE TIP 4 N COVER PLATE HIGH TEMP.SILICONE SEAL—`�� ' IB ALUMINUM HEAT TRANSFER FINS EVACUATED SOLAR GLASS TUBE PROTECTIVE PLASTIC CAP EVACUATED SOLAR TUBE DETAILS 5 Advanced Thermal Solarac/United Solar Supply LLC * wwwUnitedSolarSupply.com -www.advihermalsohir.,com 50 Aero Road * ®• NY 11716 -, USA * Phone: (888) 655.9349, * Fax: (631) 961.8815 spec SRCC approved models Our solar collector sizes for our SRCC approved models are available in three sizes presently,we can also provide custom sizes to meet any project requirement. 10 TUBE COLLECTOR 3.2 FT 22 TUBE COLLECTOR k3 FT 30 TUBE COLLECTOR 8.5 FT �n cp ADVANCED THERMAL SOLAR,LLC_ COLLECTOR DIIt7ENS10NS 6 Advanced Thermal SolarLLrJUnited Solar Supply •• o •• •m *viww.advthermalsoJar.c0M 50 Aero Road i• • 0 USA Phone-, ••• 655.9349 • 961.8815 " blaming Cn 1 7 It is a violation of the New York State Education Law for C.Da.� - any person,unless he is acting under the direction of a — O licensed professional engineer or land surveyor,to alter CDQ 6e66ae6e66eaeeieeee6-eeeeeeaeeea an item in any way.If an item bearing the seal of an engineer or land surveyor is altered,the alle ft engineer • 2 or land surveyor shall affix to thd item his seal and the. notation"affered by'followed by his signature and the. O 1 date of such alteration,and a specific desxaiption of the• CO alteration. 3 New Yak Education Law,Arlide 145§7209 = - 0 ca , �� M s- 11 C s— O CU _ o 3'-14" 3'_t1° 5'-2' U) C6 Plan View of ATS-30 unit Side Elevation View-Variable Installation Angle (n scars sscale,JV1-1W E n E Isometric View- unit 1-Aluminum Header Specifications Model ATS-3Q, N 2-Cross Bracing 48 gauge 304 Stainless Steel(4 ea) Gross area 55.11 SF - C— scwe-Ws 3-Evacuated Heat Tube(30 ea)- Net Area 26:37 SF I-- 4 --4-Locking Tube retainer Unit(30 ea) Dry Weight 243 Lbs 73 5-Side rail-18 gauge W4 Stainless Steel(2 ea) Fluid Ca 0.50 Gallons Use(2)Simpson's SDS � �'� �� O structural wood strews-T 6-Mounting foot-14 gat,ge 304 Stainless Steel(6 ea) Pressure tested to 160 PSIG U ^ 7-Pipe inlet/Outlet%"6pper Tubing(each end) Frame Bracing,&hardware is Stainless steel 316 stainless steel screws w O #SDS25300SS /`� Or � 8-Horizontal Bracing-1 ii gauge 304 Stainless Steel(2 ea) Manifold-anodized aluminum(color gray) CU �- . - 9-Stand Bracing-18 gauge 304 Stainless Steel(2 ea) � Rated capacity(ea.screw) Advanced Thermal Solar LLC 10 Center rail-18 gauge 304 Stainless Steel(1 ea) Tubes-BorosiTicate Glass 3.3 -� DF/SP-420#shear capacity 11-Adjustable length rear leg support(3 ea) vi Q SPF/HF-300#shear capacity Structural attachment Detail-Notes CertificationCO = r 1,Using(2)ut°0 z 3"stainless steel-str>1ctu2ml wood screws,attar each mounting foot(6 total)to em+ing - 1. All ATS solar collector uniis meet the requiraments of the 2010 Residential code of New York State and the " roof rafters,as shown.Use Simpson's SDS structural wood screws-Type 316 stainless steel screws specific requirements for Roof N punted collectors as per M2301.22 of the code. m #SDS25300SS;no predrilling is required, C:CD Hua Du ATS 2.When installed in accordance the specific mounting requirements shown on this drawing,the frame of the solar Heavy Duty- 2.If an existing roof rafter is not located under the mounting foot the rafter can be sistered with an 8'lo,hg collector unit can withstand wind forces of 120 MPH.If the existing structure is not designed to withstand 120 MPH CO 14 Gauge Stainless Steel matchingratter section using staggered 1Y 0 bolts at 16"o.c.or"tri le"solid bridging can be installed z mourning°Foot" . 9 99� P 9 9 winds or the existing structure is structurally unsound in any way this certification shall be void. (6 each per unit) between rafters and attached with joist hanging brackets between adjacent rafters. - 3.The collector may be mounted flush with the roof surface or elevated using the standard adjustable frame unit. 3.Coat the lag boltthreads with dear silicone sealant and use v4'stainless steel washers as shown. 4.All ATS solar collector units have been listed by the SRCC and have been certified to meet the 0&100 4.Optional mounting method:Install a 2x6 strong back member under the series of ratters where the requirements. ti tp collectors are getting installed and attach mounting feet to the strong track member using v4°stainless feel m c threaded rods with nuts and washers on each end of the rod. 5.Installation of ATS solar collectors shall only be attempted by licensed professionals in strict accordance with all EL 'z of the requirements of Chapter 23 of the 2010 Residential code of New York State. cif c .. 5.Using expansion type bolts into the existing plywood is not an acceptable mounting method. o, N r, .N Structural attachment Detail 6 Custom modifications of the collector frame,stand,cross-bracing,horizontal bracing or hardware of any kind = ^ E2 Z o�, m ° 1e Hrs 6.Any damaged roofing members discovered during installation shall be replaced/repaired before attaching will void the structural certification of this product m c X �_ m o z the solar collector units. m �, °� waaa Cl- oL> o 1 7Wmi@ - cin it is a vWft d tle New Yak Slate Edua5ai law l« CIO �+-- any person,unless he is acting under b d¢achm of a O licensed pmtessiaal enginneer a land snnrveya,b� eoeoeeeeaeeeoeeoeeeeeeeeeaoeee � an item in any way.If an dem bearing the seal of an tvghe««lwdeayeyorisaRiarati ealleftergincer 6 2 or land surveyor shall a&to tld dem his real and >` $� 410 notation'alle�by'foibwed byhis sgreture and)he, -++ 1 date of sndn alteration,and a specrTic desapfia tithe CIO _§- 1 O ® 3 afteration.New Yodc Eduatim Law,Artide 145§7209 O O CIO _ S-4 6 5-2' U.) CO Plan View ofATS-30 unit Side Elevation View-Variable Installation Angle CU O s�Hrs s�1S=ra W 1-Aluminum Header L fsometlic View-ATS 30 unit Specifications Model AFS-30. Cu 2-Cross 6racitg-t8 gaige 304 Stainless Steel(4 ea) sem.xis - Gross area 55.11 SF 3-Evacuated Heat Tube(30 ea) Net Area 26.37 SF 4-LaddngTuberelaierUnft(30ea) D Weight=Lbs 6-Siderail-18 gauge 3C4 Stainless Steel 2 ea Use(2)Simpson's SDS s-Mounting foot-14 304 Stainless Steel(6 ea) Fluid Caacity 0.50 Gallons structural wood screws-Type Pressure tested to 160 PSIG U 316 stainlesssteeis«ews 7-Pipe artetl Outlet Y4'C.opperTubing(each end) From,Bracing,8 hardware is Stainless steel , #SDS2530DSS A S 6-Horaontarl3racing-18 gauge 304 Stainless steel(2 ea) ManiM-anodized aluminum(color gray) CV 9-Stand B"raemg-48gaige304Stainless Steel(2ca} Tubes-Borosg'icate Glass 33 ~ �' Ratedrapaa(y(easaew) Advanced ThermatSotarLLC 10-C rlerra0-18gauge304StainlessSteel(1ea) to DF/SP-420#shear capacity Il-Ad}ustablelength rear leg support(3eaJ vii Q SPF/HF-300#shear capacity Structural attachment Detail-Notes Certification m r 1.Using(2)-viz'0 x 3'stainless steeL-sttxdurdwood screws,attadteach mounting foot(6 tial)to exeing 1 Ali ATS sdarootledor units meet the requirements of the 2010 Residential code of Now York State and the 1 _ foof ratters,as sham Use Simps«u'sSDS structural woodscrews-Type 316 stainless steel saews specific requirements for Root-Mounted colledas as per M230122 of the code #SDS25300SS;no prednUng is required Heavy Duly ATS 2.When installed in accordance the specific mounting requirements shown on this drawing,the frame of the solar r U 1 2.If an a ds5ng roof rafter s not located under the mounting too!the after pit be sistered w4tlr an 8'ting rn 14 Gauge Stainless Sleet matching ratter section using staggered m'0 bolls at16'o.c,or'btpld sold can be installed wads or unit can withstand wind forcesra ly u MPH Hite y way structure is not hall be id withstand 120 MPH yM mourding'FooP �� xnnds or the existing shudure is structurally unsound m arty waytis certification shall be void. � t6 eadt per rindj between ra6ers and a0adnedwith jDlefiangiig brackets betweenadjacerit rafters. 3 The collector may be mounted flush with the roof surface or elevated using the standard adrrsteble flame unit. 3.Coat the lag bolt threads with dear silicone sealant and use v4 Venless steel washers as shown 4.All ATS solar collector units have been listed by the SRCC and have been certified to meet the OC-100 4.Optlonatmounting method:Install a 2x6 strong bads member under the series of rafters.where the requirements. collectors are getting installed and attach mounting feet to the strong back member using m!stainless steel w cp_ c threaded rods with nuts and washers on each end of the rod 5 Installation of ATS solar collectors shall only be attempted by licensed professionals in skid accordance with all a ofthe requirements of Chapter 23 ofthe 2010 Residential code of New York StateL �F 5.Using expansion type bolls Into the existing plywood is not an acceptable mounting method.. >00, y n 6 Custom modifications of the collector frame,stand,cross-bracing,horizontal bracing or hardware of any kind x m l2 o cD m CO Structural attachment Detail 6 Any damaged roofing members discovered dump Installation shag be replaced/repaired before athiddng will void the structural certdiration of this product. m c x d$ ~", so a NTSthesolar collector units �rn m�m ••'o�dQ 3Q I