Loading...
HomeMy WebLinkAbout40510-Z :rax In. Town of Southold 8/30/2016 rd P.O.Box 1179 W 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38478 Date: 8/30/2016 THIS CERTIFIES that the building RESIDENTIAL ADDITION Location of Property: 7390 Great Peconic Bay Blvd, Laurel SCTM#: 473889 Sec/Block/Lot: 126.41-11 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 1/29/2016 pursuant to which Building Permit No. 40510 dated 3/4/2016 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ADDITIONS, INCLUDING REAR DECK TO AN EXISTING ONE FAMILY DWELLING,PER ZBA DECISION #6901 DATED 12/17/2015, AS APPLIED FOR The certificate is issued to Rothstein,Bruce of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40510 06/21/2016 PLUMBERS CERTIFICATION DATED 08/04/2016 Mattituck Plumbing Autho ' Signature TOWN OF SOUTHOLD moo aay BUILDING DEPARTMENT co TOWN CLERK'S OFFICE W_ • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40510 Date: 3/4/2016 Permission is hereby granted to: Rothstein, Bruce 40 Elm Sea Ln Manhasset, NY 11030 To: construct additions to existing single-family dwelling as applied for per Trustees and ZBA. Second story room uses to be determined during inspection. At premises located at: 7390 Great Peconic Bay Blvd, Laurel SCTM # 473889 - Sec/Block/Lot# 126.-11-11 Pursuant to application dated 1/29/2016 and approved by the Building Inspector. To expire on 9/3/2017. Fees: SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $440.40 CO -ADDITION TO DWELLING $50.00 Total: $490.40 Bu in ector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00, Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy- Residential $15.00,Commercial$15.00 Date. 2Q 5,-p7-1m63ca 2 0l5 New Construction: Old or Pre-existing Building: V/ (check one) Location of Property: -)39D 6'aaF/i L 6qy fjwo "Taw" n(-' Sount oL-fJ U99 8 House No. Street Hamlet Owner or Owners of Property: S&Ucd: 90THsrr77'i Suffolk County Tax Map No 1000, Section I Z-G Block Lot a 1 I Subdivision Filed Map. Lot: Permit No. q0 S � ODate of Permit. Applicant: P-0benl- Health Dept.Approval: Underwriters Approval: A n/0 Planning Board Approval: ✓ Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ 60 ?�� 21, Applicant Signature t ®��OF SO ! Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 ® yQ roger.riche rKED-town.so utho Id.ny.us Southold,NY 11971-0959 Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Rothstein Address: 7390 Great Peconic Bay Blvd. City: Laurel St: New York Zip: 11948 Building Permit#: 40510 Section. 126 Block- 11 Lot- WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Doroski Electric License No: 2941-E SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor X Hot Tub Addition X Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 6 Ceding Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures 1 Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures 7 CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 8 Twist Lock Exit Fixtures TVSS Other Equipment: 1- Exhaust Fan, 1- Paddle Fan Notes: Inspector Signature: �,e�— — Date: June 21, 2016 z Electrical 81 Compliance Form.xis OF Telephone(631)765-1802 ` Ray(62 11 M54.509. P.O.Bos 1179 Southold,NY 119714959 + Y BUELDING DEPARTMYN T t -TOWN OF SOUTHOLD D LC�COb[ AUG - 4 2016 CERTIFICATION BUILDING DEPT. TOWN OF SOUTHOLD ._ /(,o Date: Building Permit No. 4( 9 57D _ Owner: (Please print) Plumber: 19,44uS Nuol (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. lumbers Signature) Sworn to before me this day of A_0Q!, Y , 20 1 CHELSEA L. CHALONE C" L'4. 49i�: Notary Public,State of New York Registration #01 CH6287106 Qualified In Suffolk County Commission Expires August 5,2017 Notary Public, County L {�'� o��OF SOUjyol cou TOWN OF-SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ FOUNDATION '1ST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: - _ © DATE 3 INSPECTOR ' rjf s 0 Comm TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 I'NSPEC N ' ' I FOU A ION 1ST ] ,ROUGH PLUMBING T IF NDATION 2ND INSULATION FRAMING / STRAPPING ] ,FINAL FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION FIRE RESISTANT CONSTRUCTION FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) ELECTRICAL (FINAL) CODE VIOLATION CAULKING REMARKS: DATE _ -'j --INSPECTOR _ I 5 l � o��OF SOUI,yO cou�y,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION i ST , [ ] RO PLUMBING [ ] FOUNDATION 2ND [ NSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE INSPECTOR 5-10 OF S0(/Tyol eOUNTV,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INS LATION [ ] FRAMING / STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ " ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING RE RKS: yd.��A �• . . � DATE INSPECTOR 2!� f i SoVlyOIO • �o Dom'1 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ CAULKING REMARKS: DATE 6A! I INSPECTORO'� I rjf so TOWN OF SOUTHOLD-BUILDING- DEPT. 765-1802 'INSPECTION- FOUNDATION -1 ST - I ROUGH PLUMBING FOUNDATION 2ND I !�JSULATION FRAMING /STRAPPING [01FINALCA) FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION FIRE RESISTANT-CONSTRUCTION FIRE-RESISTANT PENETRATION ELECTRICAL (ROUGH) ELECTRICAL (FINAL) CODE VIOLATION CAULKING REMARKS: 0*,d9,f, C . v DATE — INSPECTOR ROBERT I. BROWN, ARCHITECT P.C. 205 BAY AVENUE GREENPORT, NY n944 631-477-9752 FAX 631-477-0973 info-ribrownarchitect.com January 28, 2016 { ; JAN 2 9 2016 Town of Southold Building Department PO Box 1179 Southold,NY 11971 Re: Rothstein Residence 7390 Peconic Bay Bvd. Laurel, NY SCTM#1000-126-n-n To whom it may concern: This letter is to confirm that to the best of my knowledge,belief and professional judgment, the proposed deck will not need a drywell/drainage system, as the decking boards will be spaced apart, allowing rain water to run through the deck and onto the ground below. Therefore the deck should be considered a permeable surface. If you have any questions or require any additional information, please contact me. Thank you for your attention to this matter. Sincerely, ,�-O ARCH�T 0� ��5 ��c �.eR caw o :�K 2 � a u_S •tea Robert I. Brown,Architect isa41 �o� qT-OF NES �p gi III :;jir,��gjjjjjjj as STATE ENE-ploy cbm, 6MIMi'~` v LVA wm- w s • • TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4'sets of Building Plans TEL:1(611) 765=1802 Planning Board approval FAX-' (631) 765-9502 Survey Soutltol(FTown:NorttiFork:net PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O. Application Flood Permit Examined 20 Single&Separate Storm-Water Assessment Form Contact: �� �60-n Approved ,20. Mail to: Disapproved a/c :Rub boonoAd Phone:4-31 Expiration ,20 " Building'Inspector �1 P � J Im JAN ? 9 2016 P�JCATION FOR BUILDING PERMIT Date 20 INSTRUCTIONS a. This application MUST be completely filled in byytypewriter or in-ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale. Pee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship,to adjoining premises or public streets or areas,and waterways. = c. The work covered by this,applicatigh may not be commenced,;before issuance of Building Permit. d. Upon approval of this,application,-,the°litiilding Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be'dccu*&6rused in wholeor in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit-shall expireifthe work authorized'has not commenced,within 12 months after the date of issuance or has-not been completed='within 18 months.from such date.-If no zoning.amendmerits or other regulations affecting the property have been enacted it the interim;the Building10spectormay authorize,jn writing;the extension of-the permit for an addition six months.Thereafter,a new permit shall be,req' red. APPLICATION IS HEREBY MADE to.,the Building;=Department,for the-issuance,of a,Building Permit pursuant to the Building Zone Ordinance of the Town,of"Southold;"Suffolk County;New York,and other,applicabl'e'Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for,removal,or'demolition-as herein described. The applicant agrees to comply with all applicable-laws,ordinances,building code,housing code,and regulations,and,to admit authorized inspectors on premises and in building for necessary inspections. o ph t or name, 'f corporation) �- � (Mailin " diess of pplican 11 State 1 whether applicant is owner, lessee agearchitect, ngineer, general contractor, electrician, plumber or builder 7S' Name of owner of premises,- M-3 (As on the talc roll or latest deed) If applicant is a corporation; signature of duly authorized officer (Name and title'of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land n which proposed work will be done: q D / ? House Number Street Hamlet County Tax Map No. 1000 Section -. Block Lot Subdivision Filed Map No. Lot 2. State existing use and occupancy, of premises and intended use and occupancy of proposed construction: f a. Existing use and occupancy - P b. Intended use and occupancy 3. Nature of work(check which.applicable): New Building Addition Alteration_ Repair Removal' ` Demolition Other Work 4. Estimated Cost. /V © Fee (Description) (To be paid,on filing this-application) 5. If dwelling,number of:dwelling,units �` Number of dwelling units on each floor If garage,,,number of cars,- l 6. If business, commercial or mixed occupancy, specify nature and extent of each type•of use. /V i 7. Dimensions of existin structures, ifany: Front �� �� Rear 5Z! !' Depth jt5;:. Height Number of Stories Dimensions of•same structure with alterations or additions:,Front �w `1 Rear �' _-E" Depth ' Height ;z' Number of'Stories 8. Dimensions.of entire new construction: Front.. Rear_ Depth, Height Number of-Stnries r 9. Size of lot: Front /Od Rear ZO �Depth 10. Date of Purchase Name of Former Owner ' 11. Zone or use district in which premises are situated - 12. Does proposed construction violate any, zoning,law, ordinancqr regulatiop?YES} N01' 13. Will lot be re-graded? YES NOWill;excess fIl`be removed from.pr,,enii'ses?,'YES - NO b EzA ' 14.Names.of Owner of re isesft= Address ;Phone allo:S �-4&,- Name of Architect A,ddres44tZ& oT Phone Nola Sl-L f7-1- 5 Name of Contractor Address �. .Phone-No. 15 a. Is-this,property within 1,00,feet-of a tidal.wetlan&or afreshwater,--Wetland? *YES NO , * IF YES, SOUlCHOLD TOWN TRUSTEES &rD'.E:C. Pl✓T�tlVl `l:'S`MAY BE:RE'QUII�ED: b. Is this-property Within,300=feetof a tidal wetland?`-* YES' NO� * IF YES,Dl.,C. PERIWIITS'MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation.plan and distances to property lines. 17. If elevation.at any point on�property is'at 10 feet or below,must;provide topographical data on survey. 18. Are there any covenants,and restrictions with respect to this.,property? * YES NOV * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OOF / � `�7�'�.lir,Cs•( being duly sworn,deposes and says that(s)he is,the applicant (Name of individual signing,cQntr''act)-above•nained, f (S)He is the (Contractor,Agent,Corporate 6f_cer,etc.) I of said owner or owners,and is duly authorized to perform or have performed the said work and to make andfile�this applicajion;' that all statements contained in this application are true to the best of his knowledge and belief,and that the work will be performed in the manner set forth in the application fled therewith. Sw to fore me 's 0 20 CYNTHIA M.CUSATJ ° qta Public, .. o Public �I0.®ICi)610Cign' of'Applicant Qualified in Su7fo10 Counb, Commission Expires Oct 20jR\ TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthForLnet PERMIT NO. )4c) 5 Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application DIFlood Permit Examined 20-6 Single&Separate Storm-Water Assessment Form Contact: Approved 20 Mail to: / A) Disapproved a/c tT60-T 1-s Phone:_�Q / -q-77 7 a Expiration 20 l -- -- q� l Bui pector PLICATION FOR BUILDING PERMIT rl'l INSTRUCTIONS Date 2 S 56PTIM(-')M 20 15 a. This appliq&iohfM ,ST be completely filled in by-typewriter or in ink and submitted to the Building Inspector with 4 sets otplans;"acouratt ilo p an to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations, for the construction of buildings,additions,or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) 7-05 &Lf Ail �2c�✓l�2-r NY 119 H-1 (Mailing address of applicant) State whether applicant is owner, lesse age �archi3tecengineer, general contractor, electrician, plumber or builder Name of owner of premises_ fj (As on the tax roil or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: )390 o R 8 v l.Ai 2 114 L-1 16 House Number Street Hamlet County Tax Map No. 1000 Section 12 Block 1 Lot Z7 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy ,Ati b. Intended use and occupancy �6-S DE-U71 q L 3. Nature of work(check which-applicable): New Building Add Alteration Repair Removal Demolition Other Work Estimated Cost__^',$ q 0,000'�vo Fee (Description) (To be paid on filing this application) 5. If dwelling,number of dwelling units �/A Number of dwelling units on each floor If garage, number of cars _ WA 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. AC/A 7. Dimensions of existing structures, if any: Front 507' 0 � Rear so'-ti " Depth RLt p-r Height 2z ' 64 Number of Stories 2 Dimensions of same structure with alterations or additions: Front 50' -(3" Rear :5-c> 8't Depthqy ' Height 21' s" Number of Stories 2 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front rod hT Rear 103 Fr Depth 3 LI5 F'- - 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated (L t 0 12. Does proposed construction violate any zoning law, ordinance or regulation?YES N0_2L 13. Will lot be re-graded?YES NO�Wil•1 excess fill be removed from premises? YES NO 40 ELM ti ► "kA- 14. Names of Owner of premises 6/7-" 9,,774srwd Address_mANHASSe r NY, ))030 Phone No. 516 - 466 - 49zq Name of Architect�o6i�rt.T �' jajz. v,,v Address 2-o;5 13Ay Avi CA hone No_631 - q-)7 - 97 5-Z Name of ContractorAddress "�'V'� - Phone No. 15 a. Is this property within 1.00 feet of a tidal wetland or a freshwater wetland? *YES Y NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERNM MAY BE REQUIRED. b. Is this property within 300 fbet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must,provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO -k * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS.. COUNTY O 9�VA-t✓ S j UOQ being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the '-Er s�ti o 0 to r a-c vi iTit:c — I G (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief,and that the work will be performed in the manner set forth in the application filed therewith. Sworntp before me this - day of 20-1 UN I A ffm vf � CYNTHIA M.CUSATI O P!1 lic l y Public,Sint,orn. "10.01 C U-Mn,,.7 V Signature of Applicant Quadfled in Mu f*CO- 'Y Commission Expires Oct 2U ��� SOUry John M.Bredemeyer III,President � OlTown Hall Annex 0 Michael J. Domino,Vice-President 54375 Route 25 P.O. Box 1179 Glenn Goldsmith Southold, New York 11971 A. Nicholas Krupski0� • �Q Telephone (631) 765-1892 Charles J. Sanders �CDUI Fax (631) 765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD Permit No.: 8721A Date of Receipt of Application: October 14, 2015 Applicant: BRUCE ROTHSTEIN SCTM#: 1000-126-11-11 Project Location: 7390 Peconic Bay Blvd., Laurel Date of Resolution/Issuance: January 20, 2016 Date of Expiration: January 20, 2018 Reviewed by: Trustee John M. Bredemeyer, III Project Description: Remove and replace existing deck with a new 286sq.ft. deck attached to seaward side of dwelling. Findings: The project meets all the requirements for issuance of an Administrative Permit set forth in Chapter 275 of the Southold Town Code. The issuance of an Administrative Permit allows for the operations as indicated on the site plan prepared by Robert I. Brown Architect, P.C., dated on September 30, 2015, and stamped approved on January 20, 2016. Special Conditions: None. Inspections: Final Inspection. If the proposed activities do not meet the requirements for issuance of an Administrative Permit set forth in Chapter 275 of the Southold Town Code, a Wetland Permit will be required. This is not a determination from any other agency. John M. Bredemeyer, III President Board of Trustees John M.Bredemeyer III,President ®��'®� S®Ury®l Town Hall Annex Michael J.Domino,Vice-President ® 54375 Route 25 t P.O.Box 1179 Glenn GoldsmithCA Southold,New York 11971 A. Nicholas Krupski Telephone (631) 765-1892 Charles J. Sanders �COU R'Mcffm [E � Do BOARD OF TOWN TRUSTEES AUG 2 9 2016 TOWN OF SOUTHOLD , BUILDING DEPT. CERTIFICATE OF COMPLIANCE TOWNOFSOMOLD # 1255C Date: August 17, 2016 THIS CERTIFIES that the removal and replacement of existing deck with a new 286 sq. ft. deck attached to seaward side of dwelling; At 7390 Great Peconic Bay Blvd.,Laurel Suffolk County Tax Map#1000-126-11-11 Conforms to the application for a Trustees Permit heretofore filed in this office Dated October 14,2015 pursuant to which Trustees Administrative Permit#8721 A Dated January 20, 2016,was issued and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is for the removal and replacement of existing deck with a new 286 sq.ft. deck attached to seaward side of dwelling. The certificate is issued to BRUCE ROTHSTEIN& SARAH ROTHSTEIN owners of the aforesaid property. Authorized Signature i ®�"�®� S®Uj�®l Town Hall Annex John M.Bredemeyer III,President Michael J. Domino,Vice-President ® 54375 Route 25 Glenn GoldsmithP.O.Box 1179 Southold,New York 11971 CA A.Nicholas Krupski ® �Q Telephone(631) 765-1892 Charles J.SandersN�'� (C D C]T�V[E D BOARD OF TOWN TRUSTEES AUG 2 9 2016 TOWN OF SOUTHOLD M. CERTIFICATE OF COMPLIANCE BIN OF SO THO TOWN®F 50UTHOLD # 1254C Date: August 17, 2016 THIS CERTIFIES that the in-kind replacement of a 104' retaining wall with two 10'-15' returns; replace existing 12 5'x14'platform in-kind in-place; and replace existing 4' wide stairs to beach; At 7390 Great Peconic Bay Blvd.,Laurel Suffolk County Tax Map#1000-126-11-11 Conforms to the application for a Trustees Permit heretofore filed in this office Dated March 26,2013 pursuant to which Trustees Wetland Permit#8141 Dated April 17,2013,was issued and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is for the in-kind replacement of a 104' retaining wall with two 10'-15' returns;rellace existing 12 5'x14' platform in-kind in-place; and replace existing 4' wide stairs to beach. The certificate is issued to BRUCE ROTHSTEIN& SARAH ROTHSTEIN owners of the aforesaid property. Authorized Signature FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD,N.Y. NOTICE OF DISAPPROVAL DATE: October 21, 2015 TO: Amy Martin(Rothstein) 205 Bay Avenue Greenport,NY 11944 Please take notice that your application dated October 7, 2015: For permit to construct a second-story addition to existing single-family dwelling Location of property: 7390 Great Peconic Bay Boulevard, Laurel,NY County Tax Map No. 1000—Section 126 Block 11 Lot 11 Is returned herewith and disapproved on the following grounds: The proposed second-story addition is not permitted pursuant to Article XXIII Section 280-124, lots measuring 20,000 to 39,999 square feet in total size, require a minimum side yard setback of 15 feet. Site plan shows a side yard setback of l It feet. 1 Authorized Signature Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. CC:file, Z.B.A. 0� BOARD MEMBERS if SO!/r Southold Town Hall Leslie Kanes Weisman,Chairperson �� y® 53095 Main Road•P.O.Box 1179 ti0 !O Southold,NY 11971-0959 Eric Dantesit Office Location: Gerard P.GoehringerT!yG Q Town Annex/First Floor,Capital One Bank George Horning 54375 Main Road(at Youngs Avenue) Kenneth Schneider COMM Southold,NY 11971 http://southoldtown.northfork.net ll -� ZONING BOARD OF APPEALS L� ' TOWN OF SOUTHOLD DECa2 2015 �, Tel.(631) 765-1809•Fax(631)765-9064 FIND GS,DELIBERATIONS AND DETERMINATION MEETING OF DECEMBER 17,2015 ZBA FILE: 6901 NAME OF APPLICANT: Bruce Rothstein SCTM#1000-126-11-11 PROPERTY LOCATION: 7390 Great Peconic Bay Boulevard(adj.to Great Peconic Bay)Laurel,NY SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps under SEQRA. SUFFOLK COUNTY ADMINISTRATIVE CODE: This application was referred as required under the Suffolk County Administrative Code Sections A 14-14 to 23, and the Suffolk County Department of Planning issued its reply dated Nov. 23, 2015, stating that this application is considered a matter for local determination as there appears to be no significant county-wide or inter-community impact. LWRP DETERMINATION: This application was referred for review under Chapter 268, Waterfront Consistency review of the Town of Southold Town Code and the Local Waterfront Revitalization Program (LWRP) Policy Standards. The LWRP Coordinator issued a recommendation dated Nov. 30, 2015. Based upon the information provided on the LWRP Consistency Assessment Form submitted to this department, as well as the records available to us, it is our recommendation that the proposed action is EXEMPT from Coastal Consistency Review. PROPERTY FACTS/DESCRIPTION: Subject property is non-conforming with 29,677 sq. ft. located in a R40 Zone. It is improved with a two story single family dwelling. It has 100.00 feet of frontage on Peconic Bay Boulevard, 337.66 feet along the eastern property line, 103.06 feet on Great Peconic Bay and 345.35 feet along the western property line as shown on the site plan prepared by Robert I.Brown,Arch. Dated Sept. 30,2015. BASIS OF APPLICATION: Request for Variance from Article XXIII Section 280-124 and the Building Inspector's October 21, 2015 Notice of Disapproval based on an application for building permit to construct a second story addition to existing single family dwelling, at; 1) less than the minimum code required side yard setback of 15 feet. RELIEF REQUESTED: The applicant requests a variance to construct a second story addition to a single family dwelling having a side yard setback of 11 feet where the code requires a minimum of 15 feet. FINDINGS OF FACT/REASONS FOR BOARD ACTION: The Zoning Board of Appeals held a public hearing on this application on December 3,2015, at which time written and oral evidence were presented. Based upon all testimony, documentation,personal inspection of the property 1 ii :f Page 2 of 3—December 17,2015 ZBA#6901—Rothstein SCTM#1000-126-11-11 and surrounding neighborhood, and other evidence,the Zoning Board finds the following facts to be true and relevant and makes the following findings: 1. Town Law X267-b(3)(b)(1). Grant of the variance will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. Two story residences are characteristic of this neighborhood and the proposed second story addition will be at the same side yard setback as the existing second stories. 2. Town Law 4267-b(3)(b)(2). The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance. The residence exists at a non-conforming 11 foot side yard setback; therefore any proposed additions will require a side yard setback variance. 3. Town Law 4267-b(3)(b)(3). The variance granted herein is mathematically substantial,representing 27%relief from the code. However,the substantiality is mitigated when considering that the two story dwelling exists at an 11 foot side yard setback and the proposed second story addition is only approximately 320 S.F. and will.not be any closer than the existing structure. 4. Town Law &267-b(3)(b)(4) No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. The applicant must comply with Chapter 236 of the Town's Storm Water Management Code. 5. Town Law §267-b(3)(b)(5). The difficulty has been self-created. The applicant purchased the parcel after the Zoning Code was in effect and it is presumed that the applicant had actual or constructive knowledge of the limitations on the use of the parcel under the Zoning Code in effect prior to or at the time of purchase. 6. Town Law $267-b. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of a second story addition, while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Schneider, seconded by Member Goehringer, and duly carried,to GRANT, the variance as applied for, and shown on the site plan dated Sept. 30, 2015, and the architectural plans labeled A-1,A-2,A-3, dated Sept. 30, 2015 prepared by Robert I.Brown,Architect. Any deviation from the survey, site plan and/or architectural drawings cited in this decision will result in delays and/or a possible denial by the Building Department of a building permit, and may require-a new application and public hearing before the Zoning Board of Appeals. Any deviation from the variances)granted herein as shown on the architectural drawings, site plan and/or survey cited above, such as alterations, extensions, or demolitions, are not authorized under this application when involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this-action. The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of nonconformity. Pursuant to Chapter 280-146(B) of the Code of the Town of Southold any variance granted by the Board of Appeals shall become null and void where a Certificate of Occupancy has not been procured, and/or a subdivision map has not been filed with the Suffolk County Clerk,within three (3) years from the date such variance was granted. The Board of Appeals may, upon written request prior to the date of expiration, grant an extension not to exceed three (3) consecutive one (1) year terms. 11 1 r Page 3 of 3—December 17,2015 ZBA#6901—Rothstein SCTM#1000-126-11-11 Vote of the Board.- Ayes:Members Weisman (Chairperson), Schneider, Dantes, Goehringer. Member Horning was absent. hi Resolution as duly adopted(4-1). Leslie Kanes Weisman, Chairperson Approved for filing /a/ /2015 Scott A. Russell ��-i�� �4 ; ST�O�][MM[»vA\'7C']E]EL SUPERVISOR NIA,N AGIEMIIEN'7F SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEN'YORK 11971 Town of Southold CHAPTER 236 - STORMWATER MANAGEMENTS) I I l Willi 6 a ( TO BE COMPLETED BY THE APPLICANT ) L DOES THIS PROJECT INN70LVE AINY OF THE 0LLGWING- ' '— Yes No !CHECK ALL THAT APPLY,- [:]KA. PPLY!❑ A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. Qtq B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑ ' 'C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. SUV- D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. E. Site preparation within the one-hundred-year f loodplain as depicted on FIRM Map of any watercourse. ❑[ F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT (Propeit}-Ouner,Des,nProf :onal em. ontracto. Other) S.C.T.M 1000 Dale DLlricl NAME jQ961j?e- �--:& PJ Ma. G -eel ton Block Lot 7� 11, i,UIL-_;I\6 DEPAF?T\IEE-F USE 0!\LY " Contact Information Reviewed By — — — — — — — — — — — — — — — — — — Date PI open tv Addl es,, / Location of Conz)truction Work — — — — — — — — — — — — — — — — — ❑ Appimed fol ptoce�ang Bolding Pelmet S101111N\atel Management Conhol Plan Not Requned — — — — — — — — — — — — — — — ❑ Slot m\\Wet N.,lanagemew Control Plan I, Retluned (F,)j\\at cl to Cn.-tneu ui�, Depdi t ment fot Re,,te\\ F'OR\1 ' Si\•IC P -TOS MAY 2014 1 S01/T�o Town 1{,,1ff Annex Tciclhon DI 765.1809 54.375 Maio Road p�p r}' "ax i 2 P.O. Box 1179 Affir ?L owt6n. utgoliLly.us Southold.DISC 11971-0959 O COMMt� t BUILDING DEFT. TOWN OF SOITHOLD BUILDING DEPARTW-NT ; TOWN OF SOUTFrOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: �,�p�k,; ��. `�'.�. ``!� Date: _ (A . f Company Name: Name: License No.: A`iz .JOBSITE-1NFOR-MA�TIION:'.(*Indic,ates� equired information) _ *Name: `Address: 7-146 `'Cross Street: *Phone No__ Z.1 7 SLI 1 I Permit No.: Tax-Map District: • 1000 -Section: Block: — Lot: *BRIEF SCRiP`ri ION OF WORK(Pliaase Print Cleady) (Please Circle All That Apply) Is job ready for inspection: �/ NO. Rough in Final To•you,need a Temp Certificate: YES I NO Temp'lnforination.(if needed) #Seniles Size: _'I Phaser r ;3Phase : ;I00 .. ; .t 50 ,20,0 s 340E. :350 400 Other, *New,parvlce: Re-connect Underground. -Nurpberof Meters, Change,of.Service ,Overhead Additional information: -PAYMENT-DUE WITH APPLICATION 1 E32-Reqursl for InspectJon Form j ®��oF sovr�®l Town Hall Annex Telephone(631)765-1802 54375 Main Road y Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 c®U 9'A�\� July 28, 2016 BUILDING DEPARTMENT TOWN OF SOUTHOLD Robert Brown, Architect 205 Bay Ave Greenport NY 11944 Re: Rothstein, 7390 Peconic Bay Blvd, Laurel TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy. Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4J1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 40510 - Addition v� DISAPPROVAL °O 0 CONC O� � MON N Z o n ]gyp � D END Fn Z FENCE rn p rn 0 K rn 7u -C Z � N O O O Lv UTILITY POLE LIL 37A GRAVEL DRIVEWAY W/TIMBER CURBING RhFgo n O ° r°ti Q) y GENERATOR = Z IENCLOSURE r Z r-nn EXISTING 2-STORY FENCE rn STRUCTURE N o ° PROPOSED SECOND n FLOOR ADDITION EXISTING 1-STORY O F 5TRUCTURE r-n SLATE ENTRY ZWOOD FENCE z - I , C) ZE •- EXI5TING D 2-STORY Z ' RESIDENCE r - Z zT z Cl rn D O n NEW WOOD DECK W RAILING REMOVE TO REPLACE EXISTING DEICK N ° BASED ON: rn SURVEYED BY z STANLEY J. I5AK5EN, JR. rn SURVEYED 23 AUGUST _ 2005 v o� AREA = 29,677 S.F. OR 0.68 I ACRES EX15TING AREA OF STRUCTURE, INCLUDING EXISTING DECK: 33 13.6 5F = 1 1 .2% gyp°° AREA INCLUDING EXPANDED AVICLATIONOFTHE FOR ANY PERSON, �° L tv 351 1 .3 SF = I 1 .5% UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER ANY �ye�tF �� ITEM ON THIS DRAWING IN _ END FENCE e'D- ANY WAY ANY A'..'THORIZED 0`5` AL'TERA'TION MUST BE NOTED,SEALED,AND CONC MON \�a �I( qD[DESCRIBED RIIBEpI;'iryIN ACCORDANCE LEANING EA5T '(� °� \ �{i L E Y i THE:e6-1tlE. O� 4 ROThSTEI N RESl DENCE CD 7390 PECONIC BAY BLVD, LAUREL NY 1 1948 SUBsep 30, 2015 BULKMERGpD D �cR�;-°8RcyiTF SCALE: I " = 30' Robert 1 . Brown vN Architect, P.C. OFN y°e 205 Bay Ave. Greenport NY admin@fairweather-brown.com G3 1 -477-9752 "r vo - 00 Q� \00 Y � �+O�1� 000 �\°0 U' Yv - CONC MON A N Z o 4� -n O D END rn Z FENCE rn U1 n p 70K Fn p Z N � O ° O c� O UTI LIN POLE LIL 37A GRAVEL DRIVEWAY W/TIMBER CUR6ING hEao� _ �RFsr O °°� C) = GENERATOR C) D 1 = z ENCLOSURE �* z 3 rn EXISTING n 2-5TORY FENCE rn STRUCTURE r'nn o 0 PROPOSED SECOND n rn FLOOR ADDITION l EXISTING I-STORY O �r STRUCTURE rn SLATE ENTRY �OUTD R r WOOD FENCE SHO Z rn n FX15TING D 2-STORY Z RESIDENCE r- Z 7 Z EEO] rom ZBA� o�u�ents ,m �j//�� � 0 NEW WOOD DECK w/RAIUNG REbI EQSTIN TO REPLACE IXBASED ON: ISTING DECK � SURVEYED BY STANLEY J. I5AK5EN, JR. Z A t SURVEYED 23 AUGUST 2005 AREA — 29,G77 5.F. OR O.G81 ACRES P � - c�rl EXISTING AREA OF STRUCTURE, INCLUDING EXISTING DECK: - 33 13.G 5F = 1 1 .2% N4000 AREA INCLUDING EXPA FI4,4bC,-h-rlONOFTHE G 351 1 .3,5r = I 1 .8% LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECT ION OF A LICENSED �O°�"0 ARCHITECT,TO ALTER?ANY "e 0oy� ITEM ON THIS DRAWING IN END FENCE oy, ANY WAY ANY AUTHORIZED .• ALTE13ATION MUST BE CONC MONOp RIOTED,SEALED,AND LEANING EAST ����`' (� DESCRMED IN ACCORDANCE O `1 WiTH THE LAW. BOTH STE I N RES 1 D E N C E 7390 PECONIC BAY BLVD, LAUREL NY 1 1948 oa sep 30, 2015' SCALE: I " = 30' �� _ Robert I . Brown ��' `„ Architect, P.C. s oFNyoe • f 205 Bayy Ave. Greenport NY ,^ admin @fairweather-brown.com G3 1 -477-9752 t ,i REScheck Software Version 4.6.2 Compliance Certificate Project Rothstein Residence D 12ega V (2 1 l5 Energy Code: 2010 New York Energy Conservation FE D Location: Suffolk County, New York Construction Type: Single-family B Project Type: Addition �D1NGDEpq� Climate Zone: 4 (5750 HDD) TQWNGFSOMOLD Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 7390 Peconic Bay Blvd. Robert I. Brown Architect, P.C. Laurel, NY 11948 205 Bay Ave Greenport, NY 11944 info@ribrownarchitect.com 'dompliance: Passes using UA trade-off Compliance- 10.2%Better Than Code Maximum UA: 59 Your UA- 53 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Ar,ea Cavity Cont. Perimeter Wall 1: Wood Frame, 16" o.c. 336 19.0 0.0 0.060 15 Window 1:Wood Frame:Double Pane with Low-E 24 0.300 7 Window 2:Wood Frame:Double Pane with Low-E 24 0.300 7 Window 3:Wood Frame:Double Pane with Low-E 24 0.300 7 Window 4: Wood Frame:Double Pane with Low-E 12 0.300 4 Window 5: Wood Frame:Double Pane with Low-E 6 0.300 2 Ceiling 1: Flat Ceiling or Scissor Truss 309 30.0 0.0 0.035 11 Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in REScheck 2 and to comply with the mandatory requirements listed in the RESch k Inspection Checklist. Name-Titl JS1Vtr UaLtf Project Title: Rothstein Residence Report date: 12/11/15 Data filename: C:\Users\Rob\Documents\REScheck\Rothstein.rck Pagel of 6 Y REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2010 New York Energy Conservation Construction Code Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. v, �`�, ..,«.•. ;�:rl:=�+,.',s?., .«,�..�,..E;: ',°t'a��"J ".F,;.�.. Sir' 'i° r �r§n ..��i;:: t_ _�,'S�•..�°t^`.�: �� u,. ';� hE,..,.. „i ae :r.�,r<, ,,l ,pl `'' ,;,r.;:;s(•'<"' 't ''.§ T' .tq ,`, .f;6t. ,sc. .£x, €t F.s- ` 5•,,,.` ,v S t ":� ' �:;,� <.�,rrr' �:�:•_`�_<, � .:!`� ��'�`" €.� �/eri ied<r:' '� F� k �.:s... >•.;.� :lrl#'.E ;hlP,re«les►ect�a /F�artttevi'e .:i4't`,ry., , 'z gY__c :; <•r. ;l;nC(" 1T1�1�ieS??v'w't, ,t2QStT11kp11YS���SYr rit�D135,•'" ,»{:� =�,3•; F�'�tt..,i.d< <,w a.3'�.. -'„r• 'r.�.€t. ?�`.t,� ,� +€��`''S” ■fp�?':t �;.i - _,-c:a' Lei:e £" '.'�' l,.4;7.y: s.,.k .$€ n ,€'e :G.,;i..�: � �.. .��'(„�`':a.!"'•.:i' u}a ” . �•+�_..,w';? .t, r.. "�,�;•� sE 'a•<. •>�,Ra":..� �I.' &c•; '. ��''`n ,t n:!!• i�:v�'..�.w g'a l,� i _' 103.2 :Construction drawings and `" a " itkA ;p< a r y's. � ❑ 1 g � ; ,,. Complies Requirement will be met. [PRl] documentation sufficient) ;'e' c.c'` ,g>`. s':`>`ai . ' .❑ Y A, ; 9 A, Does Not demonstrates energy 9Y code � =s: �A. � �.�a�-< s a �r_ :K F'�.:` �. _�•.� ��'• []Not Observable ,compliance for the building <•° .' '�`� s" Ag "' ° ❑Not Applicable envelo e. PP 103.2, !Construction drawings and s '"' `"`,ysa P ❑Complies Requirement will be met. 403.7 documentation sufficient) '» El;A Does Not [PR3]1 ;demonstrates energy Observable code ❑Not 0 ervable ;compliance for lighting and !mechanical systems. Systemspy' a .fi '; tea,°= •❑Not Applicable i ?`"iF�•�''F.c. > "a1�'•t •'Y'.aaEa: e,°, '�'�a ate? ` ; ,serving multiple dwelling units � <r: � f��+� y����,•t' •* .must demonstrate compliance ; r= ;� F•. t with the commercial code. q ,A µ '. ,„ § . „ Y ' r; 4(13 6 Y' �Heating and cooling equipment is; Heating: : Heating: ;❑Complies ;Requirement will be met. [p#t21, <,;K sized per ACCA Manual S based Btu/hr Btu/hr :❑Does Not on loads per ACCA Manual j or Cooling: Cooling: ' .',"-; ;other approved methods. !❑Not Observable Btu/hr Btu/hr ;❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) r`2 Medium Impact(Tier 2) •'3'1: Low Impact(Tier 3) Project Title: Rothstein Residence Report date: 12/11/15 Data filename: C:\Users\Rob\Documents\REScheck\Rothstein.rck Page 2 of 6 ` . ` Al 13 .,Exposed foundation insulation EComplies Exception: Requirement is not applicable. protection. E]Does Not :DNot Applicable Snow melt controls. ;E]Complies :Exception: Requirement is not applicable. ElDoes Not E]Not Observable ;E]Not Applicable Additi»maUCmmnmnento/Assummptionm: I I High Impact (Tier 1) Medium Impact(Tier 2) Low impact(Tier 3)= Pnojectllde: Rothstein Residence Report date: 12/I1/15 Data filename: C:\Users\Rob\Oocuments\REScheck\Rothste|n.rck Page 3of 6 ` , . IsectibliE. X" ElComplies :Requirement will be met. 402.4.4 :Fenestration that is not site built [FR20]1 :is listed and labeled as meeting []Does Not E]Not Observable EJNot Applicable :400 that do not exceed code k. ocom ;Requirement will be met. 0".W�"f'40C-ratecl recessed lighting fixtures plies ,,sealed at housing/interior finish []Does Not E]Not Observable E]Not Applicable NMI -1 ElComplies Requirement will be met. 403.2.2 All joints and seams of air ducts, [FR1311 :air handlers,filter boxes, and 'Or%-;" "' E]Does Not !building cavities used as return ;ducts are sealed. E]Not Observable E]Not Applicable 4'0j"-j'3',"' ,Building cavities are not used as �1 []Complies Requirement will be met. !ducts or plenums. E]Does Not [:]Not Observable " ,41E]Not Applicable 40-3'11,ffl� "VHVAC piping conveying fluids R- R- ;E]Complies ;,Requirement will be met. above 105 QF or chilled fluids :E]Does Not A'A below 55 QF are insulated to R-3. :E]Not Observable Circulating service hot water R- R- jElComplies Requirement will be met. AXI'11 pipes are insulated to R-2. ;E]Does Not :E]Not Observable 2-01.4 :EJNot Applicable M Elco 4034J!��$W,Automatic or gravity dampers are mplies Requirement will be met. installed on all outdoor air E]Do Not es intakes and exhausts. E]Not Observable *% E]Not Applicable AdditioneUCmmmmmmnts/Assummp@ons: ' 11 High Impact(Tier 1) Medium Impact(Tier 2) Low Impact(Tier 3) Pnojec±Title: Rothstein Residence Report date: 13/II/15 ` . . A I I installed insulation labeled or 1EIComplies ;Requirement will be met. installed R-values provided. 1EIDoes Not :E]Not Observable; 'EINot Applicable AdditimnaXCmmummemtm/Aasumnptioms: 11 High Impact(Tier 1) Medium Impact(Tier 2) Low impact(Tier 3) Project Title: Rothstein Residence Report date: 13y11/15 P 10 �,iPllan%-Veirl&dl el&Voirif sjAsku Value, 7 4 402.4.2, :Building envelope tightness ACH 50= ACH 50 = 1171Complies Requirement will be met. 402.4.2.1 ;verified by blower door test result: :E]Does Not [FI1711 :of&lt;7 ACH at 50 Pa.This :requirement may instead be met :E]Not Observable :via visual inspection, in which ;E]Not Applicable :case verification may need to :occur during Insulation :Inspection. 403.2.2 !Duct tightness via post- cfm cfm !E]Complies ;Exception: All ducts and air (F1411 :construction with maximum :E]Does Not handlers are located within ileakage of 8 cfm to outdoors, or :12 cfm across systems. For :E]Not Observable conditioned space. rough-in tests,verification may :[]Not Applicable :need to occur during Framing :Inspection, with maximum ;leakage of 6 cfm across systems :and 4 cfm without air handier. #03}4tV�1. Programmable thermostats ElComplies ;Exception: Requirement is installed on forced air furnaces. ElDoes Not ;not applicable. i�F Not Observable P.M E]Not Applicable E]Complies :Exception: Requirement is ,,Heat pump thermostat installed on heat pumps. E]Does Not :not applicable. R, E]Not Observable E]Not Applicable q N` "Of 6� 11co '403- Circulating service hot water , 4� mplies Exception: Requirement is Jf',!:,_­5',,,systems have automatic or DDoes Not not applicable. accessible manual controls. E]Not Observable E]Not Applicable Xlr_� [kornplies ;Requirement will be met. 40tl.t-�'MiYi,Compliance certificate posted. F R� AG E]Does Not 4 ONot Observable ; E]Not Applicable"T J Manufacturer manuals for Complies ;Requirement will be met. 'mechanical and water heating 5 :U- LJDoes Not 12, tt ­ equipment have been provided. E]Not Observable E]Not Applicable Additional Comments/Assumptions: I I I High Impact (Tier 1) Medium Impact(Tier 2) Low Impact(Tier 3) Project Title: Rothstein Residence Report date: 12/11/15 Data filename: C:\Users\RobNDocuments\REScheck\Rothstein.rck Page 6 of 6 2010 New York Energy Conservation Construction Code Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 19.00 Below-Grade Wall 0.00 Floor 0.00 Ceiling / Roof 30.00 Ductwork (unconditioned spaces): Glass&D.. Window 0.30 Door CoolingHeating& Heating System: Cooling System: Water Heater: Name: Date: Comments P EXISTING BEDROOM i 1 EXISTING BEDROOM 3'-O" SHAFT FOR HVAC DUCTS 0 V _I 1-011 • ® Bldg Dept copy from ZBA Final re,110%. �l documents S E C O N D FLOOK + ZBA Fd�:4F�9o1 S Date:1124 PAIN PLAN 114" = P PROPOSED SECOND FLOOR WALL EXISTING ACCEPT AS NOTED DIRECTLY OVER THE FIRST FLOOR WALL PROPOSED SECOND FLOOR WALL - DIRECTLY OVER THE FIRST FLOOR d �Q I WALL LSA 4'—r`II --- I I '�r r 1/0 ctu I IT IS A VIOLATION CIF TIDE LAVV FOR ANY PERSON, UNLESS ACTINO UNDER THE EXISTING WALL AND WINDOW D&RECTION OF A LICENSED TO BE DEMOLISHED ARCHITECT,TO ALTER ANY ITEM ON THIS DRA\VING IN ANYWAY ANYA',.7HORIZED ALTERATION MUST BE NOTED,SEALED,AN0 DESCR!I3EE'a IN ACCORDANCE W[H TELE F ASI. EXISTING BEDROOM KOTH5TI IN RESIDENCE 7390 PECONIC 5AY BLVD, LAUREL NY 1 1 948 Sep 3 2015 :DAcy5CAL : 1/4" = 1 '-0" 0 rt I . Brown �- Arch tect, P.C. 205 Ba Ave. Greenport NY r, admin@ alrweather-brown.com G3 1 -477-9752 f EXISTING ROOF TO REMAIN =1�47 m ZBA uments"Tb I PART KOOF PLAN PROPOSED lo NEW ROOF AREA EXISTING ACCEPT AS NOTED lo PROPOSED NEW ROOF AREA lo 0 I IS A VIOLATION OF THE LAN's FOR ANY PERSON, L NLESS ACTING UNDER TIS E IRECTION OF A LICENSED R , ®ALS ER AalY I' EM ON THIS DRAWING IM ANY WAY ANY kUlTHORIZED ALTERATION MUST BE OTED,SEALED,AND ESCRIBED IN ACCCRDANC ITH THE LAW STEI SI DENCE C IC BAY 5 VD, LAUREL NY 1 1948 D Sep 30, 2015 SCALE: 1/4' = '-0" Robert I . Brown Ar . c. EXISTING ROOF TO REMAI 205 BaAve. reenport NY admin@Li eat er-brown.com 63 1 -477-9752 _ - d r ' NEW ROOF NEW SECOND FLOOR EXISTINC FIRST LOOR WEST ELEVATION (PART) SECOND STORY ADDITION EXI5TING ACCEPT AS NOTED R n my - eF�F90 NEW ROOF NEW SECOND FLOOR :�!� m f�othstein f�esidence Bldg Dept copy from ZBA � ZBAIFile�#wgd�o�ments MMMMAi;4 Mo M6MM Date (o :4 -q 0 3-� EXIS N FI FL OR >®QX-' '30� -- sep 30, 201 5 02 z®® SCALE: I/8" = I 'O" ®� M� Robert I . Brown Architect, P.C. EAST ELEVATION (PART) SECOND STORY ADDITION EXISTING ACCEPT AS NOTED 205 Bay Ave. Greenport NY - admin@talrweather-brown.com G3 1 -477-0752 ISSUES REV151ON5 O 3"X 8" P.T. LEDGER BOARD (2) 2"X 8"P.T. Lo O I EX15TING EX15TING EXISTING EXISTING CRAW WALK-IN CRAFT WALK-IN ROOM CLOSET ROOM CLOSET _ _ (2) 2"X 8"P.T, Ea F_-Q FQ LJ V 1-011 f DECK EDAM ING In = 1'-O, 4 EXISTING ACCEPT AS NOTED EX15TING EXISTING WORKSHOP LIVE LOAD FOR NEW DECK: 40 PSF WORKSHOP 27 JANUARY, 2016 I x4 DECKING I,_0 SEPTEMBER 25, 2015 / y� rtf 1f r`'< ! '/ // METAL STRAPPING „ ' ,�. FF 2 x 8 P.T (D 1 6 O.C. METAL STRAPPING I ' THESE PLANS ARE AN INSTRUMENT OF SERVICE -rt i METAL POSTHOLDER --- (2) 2'x 8"P.T. --- 3x8 P.T. LEDGER BOARD w/ 1#2" AND ARE THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS WILL BE PROSECUTED EXPANSION BOLTS @ 12"O.C. INTO , FOUNDATION WALL i 1 / t e GRADE 2014 ALL RIGHTS RESERVED I OOR p lu oC .'••''< f • iii, ,/ <: 10" SONOTUBE RECON D ELOOK 5ECON D IFL N DECK SECTION ELEC . PLAN N M ECH . PLAN 4 1Robert 1 . Brown ,4" = I' Architect, P.C. 114" = I' U Ij EXISTING ACCEPT AS NOTED EXISTING ACCEPT A5 NOTED N EXISTING ACCEPT AS NOTED\ N I 205 Ba Ave. Greenport NY i" �� v i " admin@�alrweather-brown.com RECESSED LED DOWNLIGHTS f ,1 G31 -477-3752 IT 15 A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OFA /f ✓ f ,,,.</f/ � �� �, �, /;�•, ,,• N F.00F s'�4 ,1 "' ' • " "` LICENSED ARCHITECT, TO ALTER ANY ITEM ON i �/ � � � < I � ';`"� THIS DRAWING IN ANY WAY. ANY AUTHORIZED f TT N ALTERATION MUST BE NOTED, SEALED, AND I v DESCRIBED IN ACCORDANCE WITH THE LAW. t� SUPPLY f �t � REGISTER IN U CEILING U `A/ NETWORK CABL ; < CA 6 �3ATNF.Q.QM C40 2 nd FLOOR _..i GLIENT'7­0V✓ EfZ ` EXISTING BEDROOM a EX15TING BEDROOM �:-...•. ! ,';1Y'tl.. aT PON 07 T! pr:: c, 4: ROTHSTEIN RESIDENCE I i Lfi,.fEOi} C• , I }` `r`r 7390 PECONIC BAY BLVD. 0.- T•.��D_ '° :�„,K1°r LAUREL, NY I 1948 i i9 {. .cam r�.r•.e.°/, r9^"it�i6,.L.aJ r ,c ctrz 2 'v1 PROJECT TITLE eo SECOND FLOOR ADDITION y DRAWING TITLE . ELECTRICAL PLAN MECHANICAL PLAN ��sa1 DECK PLAN and SECTION i SCALE 2G FEBUAR 016 ...... . ....... ... . ........... ..r...... 11411 11-011 INV PLUMBING R15ER DIAGRAM r i ,..._._..._.......-.._. DRAWING NO • r) ISSUES/ REVISIONS ELECTRICAL INSPECTION REQU:RED At I OIED A'-, Inr7ED 6 DATE: o.P.,.,,. n�C/1 r FEE: d, BY: OCCUPANCY OR NOTIFY BUILDINSAM G DEFA,,'- :.-r AT USE IS UNLAWFUL t I 765 iUO2 TO 4 PA FOR THE FOLLC�r'.'11!G I^ISFECTIONS: WITHOUT CERTIFICATE 1. FO!INDAT?C�^I - T4�v'�J REQ':.RED ®� ` FOR POURED CONCRETE of � OV'CUPAN CY nn 1 ,' 2. E?GUraH - FFA!��1,"dG & PLUt><�cI(�JC� l� V' 3. X00 Od 4. FINAL,-I CONSTRU^Tr' u P•tJ P.IJST BE COMPLETE F071 C.O. FF ALL CO JSTRU;TIC'NJ SHALL MEET THE PLUMBER CERTIFICATION' REQUIREMENTS OF T HE CODES Cr-NEW ON LEAD CONTENT BEFORE YORK STATE. NOT RESPGNSIOLE FOR r , — f DESIGN OR CONSTRUCTION ERRCRS. CERTIFICATE OF OuCUP/ACY EXISTING OWALK-IN °� colic v, �/ SOLDER USED IN 11,%,^, f.-R nacN , rn N � CRAFT ROOM SUPPLYSYSTE--^ ;:'`,r'��",,-'T �! Q EXCEED 2/10 OF 't u_i' `, FENCE � rm z, COMPLY ICODES OF NEW YORKSTATE & TWN � O CODES 6 LUMBING OT _ AS REQUIRED AND CONDITIONS OF ALL PLUA.A5ING WASTE &WATER LINES 70 1fSOUTHOLDTZBA TEST NG BEFORE C-)V R OVt'NING cn „ �� EXISTING ROOF TO REMAIN SOUTHOLD TOWN TRUSTEES O 0 DOWN EXISTING STAIR TO TRUSS PLACARD;NG REWIREDI.0 EXISTING ROOM BELOW ' cg ADDITION > unu-Y FouE ` LIL3?A RETAIN STORM WATER RUNOFF GKAVEc 2x12 RIDGE 13EA PLY RATED PURSUANT TO CHAPTER 236 WITIMB RCURBIDRIVEWAY r� SHEATHING T W,TIMBER CURBING ROOFING TO MATCH 2x10 @ I G"O.C. EXISTING OF THE TOWfJ z O °oALIGN AND D GENERATOR WORKSHOP R30 BATT INSULATION = Z ENCL05URE MATCH FASCIA WITH z EXISTING D n 2-5TOEXISTING reN^ 1-/^yIl SHAFTS FOR 2x8 @ I G O.C. SPANNING 14 Z ;a 2-STOR" lam' " i 5TRUCTURE HVAC DUCTS R — PROPOSED SECOND VARIES Y2"GYP. BD. (2) 2x10 HEADER TYP. o � FLOOK ADDITION NECESSARY SIDING TO MATCH EXISTING 6EXISTING ESTORY = — 2 G @ I G O.C. O SLATE ENTRY /� STRUCTUP,E � lu OUTD R g R!9 BATT INSULATIOPJ r WOOD PEN'E ,L:: aW.__-, show r 0 i/2" CDX PLY RA �2 \ r.- _ thpQ / rn n '' --� U ¢ c~n — SNEATFIING /� R OVE EXISTING 6 JANUARY, 201 G z REMOVE EXTERIOR SIDING, r SEPTEMBER 25, 201 5 _ Ex1snNG 7'_ PROVIDE GYP, BD. '' / \ROOT` TRUCTtJRE 2-5TORY Z ,i i �, / / \ RESIDENCE I EXISTING EXTERIOR WALL ' ' \ NEW z A5 NECESSARY f Jam_ II I= II EXIST NONSTRUCTION c� rn _ -~-y- � �� � THESE PLANS ARE AN INSTRUMENT OF SERVICE ALIGN NEW FLOOR tiMTH NEW 2x10 @ 16 O.C. APJD ARE THE PROPERTY OF THE ARCHITECT. (2) 13/,'x 5Y2" 2.OE U II U EXISTING SECOND FLOOR R-22 BATT INSULATION f -� ! �� I z �- LEVEL, ADJUST WALL INFRINGEMENTS WILL BE PROSECUTED O BOT70 LAM LVL l'� Q _ I-- N �C P S y"GYP 13D. 2014 ALL RIGHTS RESERVED ' BQTTOM FLUSH WITH � ? I r o[ � HEIGNTI.S NECESSARY REPAIR EXISTING NEW WOOD DECK w/RFJLING REMOVE 'd W I W E TO REPLACE EXI•�TING �EX15TING BOTTOM OF JOISTS o fid" -'' o oC GYP. BD., SIDING, / rn PROVIDE METAL Q ` PROPOSED SECOND FLOOR WALL I Q z0 ETC, AS NECESSARY J015T HANGERS DIRECTLY OVER THE FIRST FLOOR I N N m ;l WALL o I _ u Z Luw a rn Nj U m < TAPE,SCACKLE (3 COATS) v 0 1 v w O 1 I ALL NEW AND REPAIRED O PROPOSED GYP. BD. Robert/ I Brown � f __ ! � NEWROOF AREA PAINT 3 COATS COLOR,TO PROPOSED SECOND FLOOR WALLU ; BE SELECTED DIRECTLY OVER THE FIRST FLOOR PROPOSED a O rJ z0 Architect, P.C. co .z WALL EXERCISE <o w tP f ROOMBa Ave. Greenport NY W admin@ IIrweather-brown.com G3 1 -477-9752 W2 D az ,�I-Gil Q o REMOVE EXTERIOR,SIDING, civ c� PROVIDE GYP. BD. I U IT IS A VIOLATION OF THE LAW FOR ANY PERSON, dao�o�n _1 J w I v w UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT, TO ALTER ANY ITEM ON END FEN CE THI5 DRAWING IN ANYWAY. ANY AUTHOPJZED AND ALTERATION DESCRIBEED IN ACCORDANCE WITCH T D LAW, LEP°NNG"ANT. EXISTING WALL �� AND WINDOW OJ G��P TO BE REMOVED 0D��oGj O � SECTION A M�,o�c E EXISTING BEDROOM 11411 = I ' EXISTING ACCEPT A5 NOTED EUED�J ME D CLIENT/OWNER � R 3 201,E ROTH5TEIN RESIDENCE 7390 PECONIC BAY BLVD. DUMDMG DST. LAUREL, NY 1 1948 EX15TING ROOF TO REMAIN TOMWOF'SOU7HOLD E3ASED ON: SURVEYED 5Y STANLEY J. ISAKSEN, JR. PROJECT TITLE SURVEYED 23 AUGUST 2005 ��.� �vk I.aR SECOND SLOOP, PANT �.00I` PLAN Q� oa AREA = 29,677 S.F. OR o.681 ACRES e 2 SECOND FLOOR ADDITION PANT PLAN = R {:� EXISTING AREA OF STRUCTURE, EXISTING ACCEPT AS NOTED \ ,��`,'' _ INCLUDING EXISTING DECK: 1/4" -- I -,sq�T� 41 OQ� DRA'JJING TITLE 33 13.G SF = 1 1 .2% EXISTING ACCEPT AS NOTED FOF �\,N� 51TE PLAN AREA INCLUDING EXPANDED DECK: SECOND FLOOR PLAN 3511 .3 SF = 11 .8% J ROOF PLAN SECTION IT IF A`,�IC"A.TIOM OF TI IE Ea I E FLA U 1' L_P,i,p±r FCi�r".L'-�PER,S0PI, ' L3� I MARCH, 201 G SCALE 13s�rC:T10N 0 L;CA;'�E0 AS NOTED EY15TI NG ACCEPT A5 NOTED C 'I` CT,TO A.'T€ n s"N�' ITE°;.°OSI T!-"�I„"."a?'~':�."-,a!'n DRAWING NO. C:�S;�I";' °��?'1tI`�C'C:i:�•�rBAlc.'Ca= �t'iTii T§iE L A 1. CR055 SECTION END VIEW 155UE5REVISIONS RESIDENTIAL GENERAL NOTES MISC. GENERAL NOTES 1.Td 5 PROJECT 15 CONSTRU, TION O=AN ADDITION TO AN EX STING SINGLE=AMIl_YRE5IDDJCE, -ED ata CLA 2.THESSIF HEIGHT Of THE EXISTING BUILDING 15 22'-6". THE HEIGHT OF THE ADDITION 15 22,C". .3.THE TYPE OF CONSTRUCTION I5 TYPE V(5). JI/ 4.ALL WORIK.SHALL CONFORM TO THE REQUIREMENTS OF THE 2010 RESIDENTIA-CODE OF N.Y.S.AND THE AF t PA MVDID FRAME CONSTRUCTION MANUAL 1095 SBC HIGH WIND EDITION. 5.DESIGN LOAD CALCJLAT ON ARE BASED CN: LIVE LOAD:AS PER-AB_E 8301.4,PESIDENTIAL CODE OF NEW YORK STATE. ni DEAD,LOAD:CALCULATED AS PER 8301.3 AS PER RCNYS, SNOW LOAD: 20 P'51 C POUND SNOW LOAD(AS PER FIG. P-50 J.2(5)RCNYS. 'h1N D EXPOSURE CATEGORY"C", FOR 120 MT-_`M 3 SECOND GUST. LOCATION LIVE DEAD DELECT LIMIT 55: •- IST.FL, 43 LB. 12 L/300 2ND.FL. 30 LB. 12 L/360 ATTIC(NON STORAGE) 20 LE. 10 L/ZSGo f LO K J015T ROUE 20 LB. 15 V360 DECK 40 LB. 12 L/3 GO NEW Roof G.THE ARCH17ECT,45SUMES '40 RESPONSIBILITY FOR Tt-ECONSTPUCTION MEANS,METHODS, TEClNIGUES,SEQUENCES,OR PROCEDURES,02 FOR SAFETY PKECAUTION5 ANC PROGRAMS IN CONNECTION WTH THE WORK, THERE ARE NO WARRANTIE,9, NOP,ANY MERCI-ANTIBILIT-OF FITNESS FOR A SPECIFIC USE FXF-\Es5ED "A OF,IMPLIED IN THE USE OF THESE PLANS. 7.CONTPACTCR.TO VE81I (ALL DIMENSIONS BEFORE STARTING CON5TRLCTION.DO NOT SCALE DRAWNGS. FOLLOW DIMENSIONS ONLY. 5.CONTRACTOR(S)SMALL FURNISH AND INSTAL-ALL MATERIAL AND EQUIPMENT SHOWN,LISTED,OF, DESCRIBED ON THESE DRAWINGS SUBJECT TO QUALIFICATIONS,CONDITIONS,OR EXCEPTIONS AS NOTED.CONTRACTOR SHALL FURNISH ALL LABOR,SCAFFOLDING,ANDTOOL.13 NECES5ARYTO ow24 COM'LETE THE IVCKK. 3.ALL MATERIAL SHALL BE INSTALLED IN 5TIRICT CONFORMANCE WITH MANUFACTJU5 REUIRZM-_NTE3 METAL TIE 5TRAL MAY METAL TIE 5TRAL MAY AMC,SPECIFICATIONS, 13E REQUIRED FOP, BE REQUIRED FOR 10. CONTRACTOR SHALL OBTAIN ALL REQUIRED INSPEC-IONS,APP@OVALS AND CERTIFICATE OF SLOPES EXCEEDING 7/12. OCCUPANCY. SLOPES EXCEEDING 7/12. DEMOLITION NEWSECOND FLOOR 1.CZ)NTRACTO;Z SHALL DMIOL15H WALLS, FLOOR, AND PARTS OF EXISTING ROOF AS NDICATED ON DRAWINGS AND AS NECESSARY,AND REMOVE DEBRJS. 2.GO N­PACTC K SHALL DO ALL PATC I I NG REQUIRED DUE TO REM OVA"OF E)fl 5T I NG WORK AND OR INSTALLATION OF NEW VvORK. 111 -11 r 3.ALL NEW VV0FK SHALL MATCH AMC MEET FLUSH TO EXISTING WORK AS CLOSELY AS POSSIBLE UN-ESS CTHERVOSE NOTED. -:AT­1.! 4. EXISTING STRUCTURE AND INTERIORS TO REMAIN SHALL BE PROTECTED AS NECESSARY DUPING SLOPS&`S1 DEVE D 'RED DEVOUT ON AND CONSTRUCTION. DOUBLE BEVELED --WOOD BEAM JOIST MANGER. STIFFENER EACH 5. CONTRACTOR 5HAI 1 PROTECT EXISTING SERVICES TO REMAIN AMC)SHALL NOTIFY ALL JTIUFTI!�S AND RIDGE WOOD BEAM SIDE WHERE TELEPHONE SERVICES AND MAKE ARRANGEMENTS FOR HOOK-UP, REMOVAL,OF,CAFFNG OF EGLIPMENT WOOD PLATE AS NEC!SSAPY. RIDGE REQUIRED. GENERAL CONSTRUCTION � PROVIDE ALL LABOR.,MATEIKALS,TRAN5PCPTATION,EQUIPMENT AND SERVICES MECE55ARYTO - M'LETE:ALL VIOCID AND PLAST C WORK RE=QUIRED BY THE DRAWNG5 AS SPECIFIED HEREIN,OR FX15TING F_-IRST I'LOOR :�C) REASONABLY IMPLIED.AS NECESSARY TO COMPLETE THE WORK. 2.FASCIAS,SOFFITS AM[)EXTEPICK TRIM SMALL MATCH EXISTING, 3.INT-ERICIR TRIM SHA-L MATCH EX(S-ING. 4.FRAMING ELEMENTS: RIDGE A.ALL FRAMING LUMBER SMALL BE GRADE STAMPED DOUGLAS FIR-LARCH STPLCTUPAL GRADE NO.2 OR 3ETTER. B.ALL ENGINEERED LUM3EP SMALL BE AS INDICATED ON D-,AWNG5,AND SMALL BE INSTALLED,CUT METAL TIE STRAPS AMC)DRILLED ED INACCCPDANCE WITH MANJIACTUREKS REQUIREMENTS AND SPECIFICATIONS. C.ALL SHEATHING TO BE APA RATED,EXPOSURE 1,THICKNESS AS INDICATED, D.ALL CUB FLOORING TO BE APA RATED STUKD-I-FLOOR,E>PO51JRE 1,314"MIN.THICKNEe. 10 E.ALL HEADERS 0-011 AND OVER SHALL BE SUPPORTED MTH DOU3LE UPKIGI­-TS,9'-01 AND OVER WTI TRI'LE UPRIGHTS,ALL HEADERS SHALL BE A MIN.OF(2)2`x8"OR AS SHOWN ON DR,4:MNG. F.SOL 1)BLOCKING,SMALL BE FIROVIDED FOR ALL JOISTS AND FLOOR BEAMS AS PER N.Y.S.CODE CR A5 NOTED @ 8'-0"O.C.MIN..PROVIDE 2"SPACE FOR A.]R CIRCULATION IN ROOF, G,PROVIDE DOUBI F FRAMING AROUND ALL OPENINGS(5 TAI R5,ETCJ ORAS NO-ED ON DRAW NGS, G JANUARY, 201 G M.'P OV IDE DOUBLE UP FRAMING UNDER ALL POSTS AND PARALLEL PARTITIONS OR,AS NOTED ON DRAWING. I.ALL FLUSH WOODCONNIEC-IONSSMALL BE FASTENED WITH RATED GALVANIZED META- oFEo=EAT SEPTEMBER 25, 2015 CONNECTO;Z5 BY"eIMPSON"OR APPROVED EQUAL. HANGM J. NAILING SCHEDJL�SHALL BE AS PER N.I.S.BU LDING CODE AS A MINIMUM.ALL 2"x6"STUDS WOOD 15"11/ WEjc- T ELEVATION (PART) SMALL RECEIVE 5 1 Od NAILS AT 5ILL AND FLA-E,ALL.EXTERIOR NAILS SHALL BE GALVANIZED. SEE RIDGE fCON D 5TO RY AD 1)F ATTACHED MAILING SCHEDULE EXISTING ACCEPT AS NOTED K.PLYWOOD SHEATHING TO BE NAILED Od NAILS @ 4"O.C.EXTERIOR EDGES AND Gd NAILS @ 12" UPLIFT CONNECTIONS THESE PLANS ARE AN INSTRUMENT OF SERVICE C.C. INTERMEDIATE, SEE ATTACHED MAILING SC-IEDULE. L.ALL INTERIOR AND EXTERIOR FNIS-iES TO BE SELECTEE)BYOWNER. AND ARE THE PROPERTY OF THE ARCHITECT, M.ALL ROOF RAFTERS 5HA-L BE AT-ACHED TO THE:PLATE AND STUD WIT1 GALVAN ZEE,HURRICANE INFRINGEMENTS WILL BE PROSECUTED TYPE CONNECTORS BY'SIMPSON"OF:APPROVED EQUAL. FOR TIMBER FILE FOUNDATIONS,PROVIDE HURRICANE CLIPS AT ALL PERIMETER JOIS-5 TO GIRDER CONNECTIONS. 5.ALL NEW WNDOWS TO 5E THERMAL INSULATED LOW-E GLASS,WITH ARGON GAS,IMPACT PE!S15TAIN'T AS CON N ECTI ONS DETAIL 2014 ALL PIGHT5 RESERVED REQUIRZID. G.LOAD PATHS ARE INDICATED BY SECTION DRAWINGS. 7.CONNECTIONS SMA-L BE BUILT IN ACCORDANCE WITH ANSI 1AF4 PA WCFM-1005.;SEE NAILING 5CI-EDU LE) .5.FLASI­-ING AT ALL WINDOWAND DOOR OPENINGS SHALL 3E EPDM OR APPROVED RUBBERIZED MEMBRANE. NAILING SCHEDULE 0.FLASHING AT ROOF CONNECTIONS,VALLEYS,CHIMNEYS AND CRICKETS SMALL BE ALUMINUM. (PER,AP t PA AMERICAN WOOD COUNCIL WFCM FOR 10.STEP FLASHING SHALL BE USED AT ALL INTERSEC-IONS OF SLOPED AND VERTICAL SLPFACES,EXCEPT STS'FLASHING AND COUNTER-AND CAP-FLASMING SMALL M USED AT INTaP5ECTION OF ROOF AND ONE AND TWO FAMILY DWELLINGS 93553CHIGHWNDEDITION) Ro 19 e,rt 1 . Brown CHIMNEY,AND ROOF AMID WA-1-5. JOINT DESCR PTION NUMBER OF NAILS NAIL E-PACI 14G 1 1. INSULA--ION SHALL BE BATT INSU-ATION OF THICKNESS INDICATED ON THE DPAWNGS AND SHALL BE ArchitectP.C. 2-U2 It. DENSITY FIBER-GLASS BATTS CONFORMING TO THE SPECIFICATIONS FOR PRE-FORMED ROOF FRAMING , FIBROUS GLASS INSULATION, NAAMM STANDARD 51, ][7-70. RAFTER-0 TOP PLATE(TOE-NAILED) 3 PER RAFTER ROOF 2,NMI INTERIOR DOORS SMALL MATCH EXISTING, CEILING JOIST TO TOP PLATE(TOE-NAILED) 3 PEP,JO ST NEW 3, NEW'1AKDWARE SMALL MA-CH EXISTING. 205 M Ave. Greenport NY 14.GYPSUM BOARD SHALL BE EASED EDGE--`YPE,CONFORMING TO ASTM C3G,AND SHALL BE CEILING JO'5T TO PAPAL-EL RAFTER(FACE-NAIL`))3 EACH LAP CEILING JOIST LA'S OVER PARTITION((FACE-NAJLF1_$ EACH LAP admin@ airweather-brown.com '511FETROCK SW'BY U.S.GYPSUM CO.OR AFPPOVED EQUA_ GYPSUM WALLBOARD THICKNESS SMALL BE lz;� 112" RIDGE S-RAP(EACH END) 2 PER TIE 63 1 -477-9752 15.ALL NEW AND REPAIRED GYP.BOARD SHALL BE TAPED AMC)5PACKLED TdPffr(3)COATS.ALL E<TFRICK BLOCKING TO RAFTER(-OE-NAILED 2-8d EACH END CORNERS SMALL HAVE METAL CORNER BEADS, RIM BOARD TO RAFTER(END-NAILEc') 2-1 Gc EACH ENE) FINISHES WALL FRAMING TOP--ATE TO TOP PLATE(FACE-NAILED) 2-1 Gc PER FOOT 1. CERAMIC TILE F-OCIP 5EALL BE SELECTED BY OWNERS AND INSTALLED WTH THIN TOP'-ATES AT INTERSECTIONS(FACE-NAI-ED) 4-1 Gc JOIST EA.SIDE --—-——— SET ADHaBIVE, STUD TO 5TJD'FACE-NAILED) 2-1 Go 24"O.C, 2.EXTERIOR PAINT SHA-L BE LATEX ACIRYL C BY BENJAMIN MO RE OR APPROVED HEADER TO HEADER(FACE-NAILIEC) 16d I G"O.C.ALONG :-I)GE5 IT 15 A VIOLATION OF THE LAW FOR ANY PERSON, EQUAL,APPLIED IN ACCORDANCE VATH MANUFACTURERS SPECIFICATIONS AMC) TOP OR BOTTOM PLATE TO STUD(END-NAILED) 2-1 Gc,3-1 Gd,4-I Cd PER 2x4, 2x0,20 RESPECTIVELY UNLE55 ACTING LIN DER THE DIRECTION OF A RECOMMENDATIONS. COLORTO5ESEL:-:CTZD. 3.M5TING INTEIRICK'AALLS AND CEILINGS IN ROOMS AFFECTED BY THE IMOPIK. BOTTOM PLATE TO FLOOR JOST, BAND JOIST, LICEN5ED ARCHITECT, TO ALTER ANY ITEM ON SMALL BE CLEANED AND REPAINTED. NEW WALLS AND CEILINGS SHALL BE SEALED END JOIST OR BLOCKING(FACE-NAILED) 2-1 Gc PER FOOT THIS DRAWING IN ANYWAY. ANY ALITHORIZED AND PA INTED.FAINTING SMALL BE TWO (2)COATS BENJAMIN MOORE AQLA PEARL FLOOR FRAMING ALTERATION MUST PIE NOTED, SEALED, AND LATEX PAINTED,COLOR TO BE SELECTED. JOIST TO 5111,TOP FLATE TO GIRDER(TOE-NAILED)4-5d FER JO ST DESCRIBED IN ACCORDANCE WITH THE LAW. 4. INTERIOR TRIM SHALL 3E SANDED SVOOT-i,PRIMED,AND FIN SHED wTH Two(2) COATS BENJAMIN MOORS LATEX ACRYLIC SEMI-GLOSS FAINT. BRIDGING TO JOIST(TCF-NAILED) 2-5d EACH END fl BLOCKING TO JOIST(TOE-NAILED) 2-5,1 EACH END NEWSECOND FLOOR BLOCKING TO SILL 01,TOP PLATE(FACE-NAILED) 3-1 Gc EACH BLOCK HVAC LEDGE STRIP TO BEAM'FACE-NAILED) 3-1 Gc EACH JOIST 1.PROVIDE ALL LABOR,MATER AL,TRANF3PCRTATION,EQUIPMENT AND SERVICES J015T ON LEDGE TO BEAM(TOE-NAILED) 3-5d PEP Jo ST NECESSARY TO EXTEND THE EX15TING HVAC SYSTEM-0 HEA_-AND COO-THE NEW BAND JOIST TO JOIST(END-NA LED) 3-1 Gc PER JO ST LIVING SPACES AS REQUIRED'BY THE DRAW NGS AND SPECIFICATIONS,Of', BAND JOIST TO SILL OR TOP PLATE(TOE-NAILED) 2-1 Gc PEP FOOT REASONABLY IMPLIED AS NrCE55ARY TO COMPLETE TO WORK,AND IN COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. ROOF SHEATHING 5TRUCURAL PANELS 15d (TABLE 3.5) PLUMBING DIAGONAL BOARD SHEATHING I.PROVIDE ALL LABOR.,MATER ALS,TKAN5PC RTA 'x0 OR 1X5, 2-5J PEP,SUPPORTTION, EQUIPMENT,AND SERVICES �Ix 10,OR WIDER 3-5d PER SUPPORT NECESSARY TO COMPLETE ALL NEW PLUMBING WORK PEQUI;�ED BYTHE00MINGS AMC,SPECIFICATIONS,OR REASONABLY IMPLIED AS NECESSARY TO CCMF_ETE THE CEILING SHEATHING WORK, GYPSUM IVAILL13OARD 5d cooler,3 7"EDGE/ IC"FIELD 2. CONFORM TOTHE NEW YORK STATE ENVIRONMENTAL CONSERVATION LAW WTh REGARDS TOWATER SAVING AND CONSERVATION. ALL FIXTURE-135HALLBEONTHE WALL SHEATHING 3.9)HE (TABLE APPROVED"LIST OF CERTIFIED WATERSAVING PLUMBING FIXTURES"A-c-'UBLIS DBY STRUGURAL PA�Iffl_ OD EX15TING f I PIET FL 'OR THE NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION. FIBERBOARD PANELS 3. A-L WORD,ON THE PLUMBING SYSTEM SMALL BE 1ERFOPMrD BY OR UNDER THE 7/1 G" GID 3"EDGE I G"FIELD 5UFERVISION OF A PROPERLY LICENSED VASTER Lu PLUMBER. UPON COMPLETION,THE 25132" 6D 3"EDGE/6"FIELD PLUMBER SHALL PROVIDE A SOLDER CERTIFICATE AS REQUIRED BY THE TOWN OF GYPSUM WALLBOARD 5c coolem 7"EDGE/ IC"FIELD CLIENT OWNER SOUTHOLD. HARDBOARD 5c (TABLE 3.9) 4.THE CONTPACTORSHALL OBTAIN,SUBMIT,AND PAY FOP ALL PERMITS, FAPTICALBOAIRD PANELS 80 (TABLE 3.9) CERTIFICATIONS,LICENSES AND INSPEC-IONS ASS REQUIRED BY LOCAL,STATE,AMC) FEDERA-AUTHORITIES,AND ANY OTHER APPLICABLE JUP13DICTION, DIAGONAL BOARD SHEATHING I"xG`OP I"X6, 2-5d PER.SUPPORT ROTHSTEIN RESIDENCE 11 ELECTRICAL I"x 101'OR WIDER, 3­5d FER.SUPPORT 7390 PECONIC DAY BLVD. 1.FURNISH ALL LABOR,MATERIALS,EQU PMENT,-1-ANT,TOOLS,AND SERVICES - -ATION OF ALL NEW NECESSARY AND P�!QLIRED FOR PROPER AND COMPLETZ INSTAL FLOOR SHEATHING ELECTRICAL SYSTEMS AND�,E_ATED VvCPK INCLUDING,BUT NOT LIMITED TO: STPUCURAL PANELS LAUREL, NY 1 1948 CONNECTIONS TO PREVIOUSLY INSTALLED ELECTRICAL SYSTEMS,WRING, _IGMTING, 1"OF,LE55 811 G"EDGE/ 12"FIELD SERVICES, FEEDERS,DISTRIBUTION AND PROTECTION 531-11-MENT,CONNECTIONS TO GREATER TH AN I� I od G"EDGE/G"FIELD APPLIANCES, GROUNDING,AMID ALL I NCLUIDI NG A-L CON NECTIONS AND DEVICES DIAGONAL BOAR SHEATHING 'AITHIN THE SCOPE OF THE WORK AS SHOW)ON THE APPLICABLE DRAWINGS AND I 11>1161,OR N511 2-8d PER SUPPORT AMC,SPOFICATION5 AMID AS NORMALLY SFEC FIFD 1\1 THIS TYPE OF PROJECT AND I N,10'OR WIDER 3_8d PER SUPPORT INCI_UDING CONNE(71ONS TO PREVIOUSLY INSTALLED TPANbFORMEKS AND ELECTRICAL DISTRIBUTION SYSTEMS. PROJECT TITLE 2.ALL WOPK SHALL CONFORM TO THE RE IDLIKEMENT5 OF THE 20 0 ELECTRICAL EAST ELEVATION (�'AN I ".3ECOND 51-ORT" AL'UMON CODE OF NEWYORK STATE,T115 NATIONAL ELECTRICAL CODE, NEPA NO,70-1984 (NEC), LOCAL UTILTY STANDARDS,OCCUPATIONAL SAFETY AND HEAL H CAT(OSIHA), CLIMATIC AND GEOGRAPHIC CRITERIA EXISTING ACCEPT AS NOTED THE NAj_IONAL Iff-ECTRICAL MP,NUFACTURE;,'S'ASe-O(-,IATION(NEMA)AND ANYOTHEP .APPLICABLE CODES. IN THE!EVENT OF CONFLICT,THE MORE STRINGENT GROUND 5NOW LOAD 20 PSF (PEP,FIG. R301 .2 (5)RCNY5) REQU I RZM E NT5 W ILL APPLI. WIND SPEED 120 MPH (PEP,FIG. R301 .2 (4)RCNY5) SECOND FLOOR ADDITION 3.ALL PRODUCTS JSED FOR ELECTRICAL WORK SHALL 13EA;Z THE UNDERWRITERS LABCRATOPlEe,INC.LABEL AND BE SUITABLE FOR,THE ENVIRONMENT IN"ICH THEY SEISMIC DESIGN CATAGORY 13 (PER 5ECT. P,301 ,2(2)RCI\IY5) WILL BE INSTALLED. WINTER DESIGN TEMP I I*F (PER TABLE N 1 10 1.2) 4.ALL WORK ON THE ELECTRICAL SYSTEM SHALL BE PERFORMED BY OR UNDER THE SUFERVISION OF A PROPERLY LICENSED VASTER ELECTRICIAN. FLOOD ZONE X (PER FEMA MAP) 5.THE CONTRACTOR SHALL OBTAIN,SUBMIT,AND PAY FOR ALL PERMITS,LICENSE'S FROST LINE DEPTH 30 DRAWING TITLE AMC,INSPECTIONS A5 REQUIRED BY THE LOCAL,STATE,AMC)'ZIDERall-ALIT'HOPITIES, WEATHERING PROBABILITY SEVERE (PEP, FIG, 8301 .2(3)RCNY5) AND ANY OTHER APPLICABLE JURISDICTION. G.CARE30N MONOX DE:DETECTORS IN CONFORMANCE WITH APPLICABLE CODES DESIGN LOAD CALCULATIONS (UNIFORM LIVE LOADS) SMALL BE CONNECTED TO THE LIGHTING C PCUITe WITH NO INTERVENING WALL SWTCH, LINE CORD-CCMN3CTED, DIRECT PLI-G-IN,AMC-BATTERY POWERED ALARMS ROOMS OTHER THAN SLEEPING 40 P,91 (PEP 7A5LE 301 .5 RCNY5) ELEVATION 5 ARE NOT ACCEPTABLE. ALARMS SHAL_BE INSTALLED ON EACH LEVEL ON W11CH SLEEPING QUAR-ERS ARE LOCATED. SLEEPING ROOMS 30 P,91 (PEP,TABLE 301 .5 RCNY5) 7.SMOKE DETECTORS IN CONFORMANCE WITH THE ELECTRICAL CODE OF NEW YCKK ATTICS WITH LIMITED STORAGE 20 P51 (PER TABLE 301.5 RCNY5) NOTE5 STATE AND THE RESIDENTIAL CODE OF NEW YORK S-ATE,THE NFPA NATIONAL FIRE ALARM CODE NO,72-1003 SMALL BE PROVIDED OUTSIDE EACH SEPARATE SLEEPING ATTICS WITHOUT STORAGE 10 P191 AREA,IN EACH SPLEEPING AREA,AM[)ON EACH FLOOR LEVEL. STAIRS 40 P,91 (PER TABLE 301 .5 RCNY5) 5CALE! CONTRACTOR SMAL_COORDINATE WITH OWNERS ALARM COMPANY FOR SMOKE AND 2 MARCH, 201 9 BURGLAR,ALARMS AS NECESSARY. i-I IF A Wo,_ArinTl 07:THE 114" P-0" R PVV F,'_ C_�,�RED Ap, L/117,1!F0, 0 DRAWING NO. Ut7LE]SS Lf,,!7'Z73 THE r7 0 r 7 i%L I C F�'!c-7,-L::) /,,F'CM,TECT,TO IT17,"OM TI. 1:7E;---.v1',!'i,.G IN V TVI T I- L ISSUES/ REVISIONS O 3"X 8" P.T. LEDGER BOARD (2) 2"X 5"P.T. iT 10�I I O (D Z x — N (d EXISTING EXISTING EXISTING EXISTING CRAFT WALK-IN CRAFT WALK-IN ROOM CLOSET ROOM CLOSET L_J — — (2) 2"X ,5"P.T. f 21-7 DECK TAM I NC 1"4 — = 1, -0" EXISTING ACCEPT AS NOTED EXISTING EXISTING WORKSHOP WORKSHOP LIVE LOAD FOR NEW DECK: 40 P5F f, 27 JANUARY, 201 6 .64 . . '"- i .' •' METAL STRAPPING 1 0 I x4 DECKING !�_.0�: SEPTEMBER 25, 2015 2 x 8 P.T @ 16t O.C. 1 tt t.:r t Q m METAL STRAPPING ch THESE PLANS ARE AN INSTRUMENT OF SERVICE �� U z U -(2) 2'x 8"P.T. ---- 3x8 P,T. LEDGER BOARD w/ 1#2" AND ARE THE PROPERTY OF THE ARCHITECT, METAL POSTHOLDER --- EXPANSION BOLTS @ 12 O.C. INTO INFRINGEMENTS WILL BE PROSECUTED CV/ ,/ GRADE FOUNDATION WALL 2014 ALL RIGHTS RESERVED , — rr °//7,77,77177,77*rri 10" 50NOTUBE SECOND fLOOI ,, f ' ff, it/�✓ SECOND ELOOK ° °, MECH . PLAN N DECK SECTION ELEC . PLAN Robe- rt t I . Brown 1/4" = I' Q) 1/4" = 1' 4 Architect P.C. EXISTING ACCEPT AS NOTED EXISTING ACCEPT AS NOTED EXISTING ACCEPT A5 NOTED . N , 205 Ba Ave. Greenport NY RECESSED LED DOWN LIGHTS �t U U admin@alrweather-brown.Com Ilk G3 1 -477-9752 ° IT 15 A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A ROOF �•- - i,,�:.�. . ,i:.-C.. ` °,,�:t,';. LICENSED ARCHITECT, TO ALTER ANY ITEM ON N N THIS DRAWING IN ANYWAY. ANY AUTHORIZED � U ALTERATION MUST BE NOTED, SEALED, AND U DESCRIBED IN ACCORDANCE WITH THE LAW. d `_r SUPPLY f s REGISTER IN X U CEILING U NETWORK CABL ' CA 6 bATHRQ M 1 i 1 CLIENT/OWNER EXISTING BEDROOM EXISTING BEDROOM f ITIFAVi _ P.7.1.�r,��Tfr� ROTHSTEIN RESIDENCE U Lr=Ss f,C T€t"'G eJ%:.•,..=. , 7390 PECONIC BAY BLVD. _.w...................... rI�"� LAUREL NY 11948 f'7CFIITEuT T0d':I_7ESAf.'Y //'�al',rC•vEJ'^C`Ri'+. L7 tF W T I i 6 4 t: L';'1`. PROJECT TITLE SECOND FLOOR ADDITION 0� DRAWING TITLE ELECTRICAL PLAN ' MECHANICAL PLAN a q � r . yc DECK PLAN and SECTION ...._..._. ....._....._ ......_...._.. SCALE _,...... .......,r.rr.. .....• 26 FEBUARY, 201 6 ,_......,__, ...._ �. LUME31NG K15ER DF, DRAWING NO. �i .I_