Loading...
HomeMy WebLinkAbout40789-Z o�sUfFO(,fcOG Town of Southold 8/25/2016 3 y P.O.Box 1179 0 o g 53095 Main Rd yal �o`� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 38475 Date: 8/25/2016 THIS CERTIFIES that the building COMMERCIAL ALTERATION Location of Property: 8850-Route 25, Laurel SCTM#: 473889 Sec/Block/Lot: 122.-7-3.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/17/2016 pursuant to which Building Permit No. 40789 dated 6/21/2016 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: INTERIOR ALTERATIONS TO AN EXISTING RESTAURANT AS APPLIED FOR The certificate is issued to Cofam Realty Co of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40789 08-09-2016 PLUMBERS CERTIFICATION DATED Autho ' ed ignature o�sU oFF ��co TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40789 Date: 6/21/2016 Permission is hereby granted to: Cofam Realty Co Attn: Controller 10 Rabro Dr Hauppauge, NY 11788 To: construct interior alterations (hand sink and kiosk) to an existing restaurant as applied for. At premises located at: 8850 Route 25, Laurel SCTM # 473889 Sec/Block/Lot# 122.-7-3.1 Pursuant to application dated 6/17/2016 and approved by the Building Inspector. To expire on 12/21/2017. Fees: COMMERCIAL ADDITION/ALTERATION $250.00 CO -COMMERCIAL $50.00 Tota . $300.00 Building Inspec Foi ni No 6 -t-OWN OE S0UTH0LD BUILDING DEPARTMENT TOWN BALL 765-1802 APPLICAT[ON FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the Following. A. For new building or new use: 1. Final survey, of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept- of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4- Sworn statement from plumber certifying that the solder used in system contains less than 2/l0 of I% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 19S7) non-conforming uses, or buildings and"pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate.of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50:00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy oFCertificate of Occupancy-X23- 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. f, l New Construction: Old or Pre-existing Building: (check one) Location of Property: U410 9b1In14'fZI'LULtIL House No. Street Hamlet Owner or Owners of Property: ('aMA,0 VF-Ad.A-1 C M A" Suffolk County Tax Map No 1000, Section 22 Block. 6-1 Lot r Subdivision Filed Map. Lot: Permit No. -1 U 1 Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certifi e Final Certificate: (check one) 4_ppli- Fee Submitted:,$ t Signature pE SO(/ry®l � o Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 �Q roger.riche rt(-town.southoId.ny.us Southold,NY 11971-0959 c®UNTY,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Cofam Realty Co Address: 8850 Route 25 City: Laurel St: New York Zip: 11948 Building Permit#: 40789 Section: 122 Block: 7 Lot: 3.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Double R Contracting License No: 4027-E SITE DETAILS Office Use Only Residential Indoor X Basement Service Only Commerical X Outdoor 1st Floor X Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 8 Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures IA TVSS Other Equipment: Interior Alteration and Additions to Include; 3- 220 Drop Cords, 1-20A Display Circuit, 1-3 ph 30A Receptacle. Notes: Inspector Signature: Date: August 9, 2016 OOElectrical 81 Compliance Form.xls SOUjyO! TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [7FINAL ULATION FRAMING / STRAPPING [ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: C. O. . DATE oY INSPECTOR �loc� SOplyOlo t o • �o cOUM`10c`� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) REMARKS: DATE INSPECTOR ' FIELD lNSPE=ON=- VORt D +COIvl IF FOUND,ktlON(1ST) ............. ...:_........ -- -- VOUND4,T70N'(M) ROUGE(FR012NQ& PLUMBII�i'G �•.- � � INSULATION PER N.Y. , y STATE ENERGY CODB Bq 0016 �.dr - y Fj.I.lq AU ' 1 Z � • o 0 TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL CUmmmzi a C 25o- Board of Health SOUTHOLD, NY 11971 9' 50 - 4 s is of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Su ey SoutholdTown.NorthFork.net PERMIT NO. 0 Check Septic Form N.Y.S.D.E.C. Tstees C.O. pplication Flood Permit Examined ,20 Single&Separate CStorm-Water Assessment Form Contact: Approved ,20r n Disapproved a/c A(I.CN•I1Eci Phone: (ail- 424-8490 Expiration_� ,20____(- ' • �— Building Inspector APPLICATION FOR BUILDING,PERMIT Date Q , 20 (y INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws,Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housin code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. Sign re of applicant or name, if a corporation) /12) Z&j dY. kkOViIMZ� . AI (Mailing address of applicant) (I 4 State whether applicant is owner, lessee age , architect, engineer, general contractor, electrician, plumber or builder A&W t'-ry Name of owner of premises Co ) 2gAf_-r!J C,9wtp4,kfiJ ��±`� e�lc� ,� fir{ a3p, , (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer --�>_f,&JJ `I �o l�6aJ . PI S�D TI (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License.No. Other Trade's License No. 1. Location of land on which proposed work will be done: OF60 MhA d 11 , House Number StreetHemet ¢%svj County Tax Map No. 1000 Section 22 Lot 3 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed,construction: a. Existing use and occupancy Gpv L)At-05 &�6s-(41294=,:::j b. Intended use and occupancy &AU 5 ��,(4,44b—r A 1 3. Nature of work (check which applicable):New Building 'tion`,C1a„ 'Alteration Repair Removal Demolition Other Wor ��, — d (Description) K 4. Estimated Cost 4c) voo Fee (To be paid on filing this applicatio 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. Rx2siu -� 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO—X- 13. Will lot be re-graded? YES NOWill excess fill be removed from premises? YES NOV 14. Names of Owner of premises6of4&j N 'Cz�,Address 11 P-D, Phone No. (q14) 5gz---7q12 Name of Architect K&,3u6-f4 �ll�Cl�r��� Address �,I s. ,uAl�tc Auf hone No/2� -�osl Name of Contractor Address tWSO . PP, Koo2 Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NOA * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF 5 Scl J p 411 being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the (Contracto , agent Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this to day of ­aVr,Z-- 20 MELAN1E V BROWN irr� , Publ1%State of New Notary Public 01BR4908712 gnature o Applicant auall!10 in Suffolk Cou nV IQomm Won Ex0mv C Town Hall Annex 4 Telephone(631)765-1802 _ 54375 Main Road c 631}7 5 P.O.Box 1179L!LS k 11-�L-CA L I Southold,NY 11971-0959 JUL 2016 BUILDING DEPARTMENT TOWN OF SOUTHOLD BUILDING DEPT. APPLICATION FOR ELECTRICAL INSPE0loFSOMOLD REQUESTED BY: Date: Company Name: Do cc d e Com a- Name: a c— License No.: p Address: �( Gam• �TC43- /v q2 Phone No.: JOBSITE INFORMATION: (*Indicates required information) *Name: C® 4ez,(Vv ��� *Address: 866-0 Az« *Cross Street: �► i�/� *Phone No.: 6 3/-- O qc-,�- Permit No.: Z/a 7 S>Q' _ Tax-Map District: 1000 Section: Block: 7 Lot: Y. *BRIEF DESCRIPTION OF WORK(Please forint Clearly) ,�2y181/Q,tFE �«�1�S a-pLd SAO Sri' (Please Circle All That Apply) *Is job ready for inspection: YES/ NO Rough In Final *Do•you need a Temp Certificate: YES/ NO Tennp Information(if needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 . 400 Other iNew Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION .82=Request for Inspection Form D o- ue R Contracting Electric Security July 6, 2016 Town of Southold Town Hall Annex Building Department 54375 Main Road Southold, NY 11971 Dear Sue/Tracey, Please see enclosed our Application for Electrical Inspection form along with the check for $125 that we discussed on the phone. This is for some electrical lighting and equipment outlet renovations at McDonalds 8850 Main Road, Mattituck, NY 11952. Thanks for your help with this. Let me know if we need to provide you with anything else. Thank you, A601 D DIG D Glenn James JUL - 7 2016 BUnDING DEff. TOWN OF SOUTHOLD 19 West Jefyrn Blvd Deer Park, NY 11729 Tel.631.249.1117 Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 �® COW,� August 5, 2016 BUILDING DEPARTMENT TOWN OF SOUTHOLD Cofam Realty Co Attn: Controller 10 Rabro Dr Hauppauge NY 11788 Re: McDonalds, 8850 Rte 25, Laurel TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy. lication for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. q A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Presen vation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT —40789 — Interior Alterations TOWN , OWNER STREET VILLAGE, _DISTRICT SUB. ;LO FORMER OWNER OWr NER NE r ACREAGEj! � C � ,/ y , " �7 _ /SW 1 TYPE OF BUILDING �C:A�l d6K P lr�i� "' 1" l; RES. Z: SEAS. VL. FARM COMM.- 4:1 IND. CB. MISC. LAND IMP. TOTAL DATE REMA KS i' O AYE ( n =� rV ''• G COND _ ,t&ORMAL ELOWB_QVE � lu 7 arum `� 9eccre Va ue Per A e �rP� 3l2, 14Z G!;,� Tillable 1 v a Tillable 9- Tillable, TiIlable, 3 Woodland - 14—d A 0•-'rt- _ / Swampland Brushland � � p � _ a ?` 8'17 73 Sa!� fFt.�.l� 4.4 PO- T,CAL%yCaifP /a J. M. Fe ®rX. f —House Plot__ dii -2 -1ZOOM 200 7-611 Z /3 Total aQ SRX, x" ` ■ttttttttt■t®t■■t■t■ �-.-�` `,..�- � .mow ■■I■■■■■■■■■■■■■■t1■■■ ■�■■ttttttttt��■��t■■ 5VP" ■■■■■■■■■■■■■■■■■■■■ -,BasementExt. Walls Interior Finish .. Fire Place Driveway- Mal SC.D.H.S. # C-10-93- 011 7- C C 6° p ✓. 0 U J A 11n a 1 a Q° MLj q FRANX7ER RPNY N EN CEN GARP v � zas• °f - �� 14 . -pOg -o'o- �" t31\1• eii, �' � n „1 `�d'Qs�'I1gy,�°� ` � 'N GOA OLD MAIN ROAD 4 �_ L �•'d r m ° -c in e +7[� 0' \ � t 'o SURVEY OF , PROPERTY ATMATTITUCK TOWN OF SOUTHOLD J SUFFOLK COUNTY, N.Y. 1000-122-07-3.1 m Scale: 1"=40' r April 3, 1995 i•,.• July 27, 1995(final) - - - - - __. - , — ,�' e � 268.26., 0.`�• i , a mlf *• i� y1'2, 1'1--r S. 94.4270• W. y MAIN 1 1y ? :? 95 C, 3 ROAD �i :•.� ;i .,:`c.,� OLD NEW YO �j Yan�1KsJ' �,dk ,.•..��...; .c{•'t�tix.� P�� t,Merxo Ry I� •i� ,r-,�aa`m 4a.�tad+a;xsy. 5� ,�`' FQ ANY AL TERATICW OR ADDI rM TO TMS SURVEY ASA VIOLATION r S'i-�a OF SECTION '109 OF THE NEW YORK STATE IDf/CAT/GN LAW y� �I EXCEPT AS PER SECTION TE09-SUSMV1570N E ALL CERVF.Y,A�,. S. LIC. NO. 496/8 HEREON ARE VALID FOR TM MAP AA®COPIES W EREOF OA7.Y F WHOSE P OOR COPES�IP�ThE S HEREON(SSED S1EAL OF ME SLRVEYOR E $, P.C. AREA= 3.00 Acres P I o 0 ADDITroruLLY TO CONPLY WITH SAN LAW THE T7E�ARM'ALM EDY Y• ELEVATIONS ARE REFERENCED TO ARIST BE usm 6Y ANY AAP ALL SCFVEYORS UTAlZN6 A CGP AN ASSUMED DATUM. OF ANOTHER SLIRVEYW$AUP. TERMS SUCH AS YKSPECTFA'AND MAIN ROAD eROLrrrlr-ro-DAIF*ARE NOT w CO U4NCE WTlX TA£uw SOUTHOLD, N.Y. 11971 90-168 (MMIDD ATE A`CORO® CERTIFICATE OF LIABILITY INSURANCE D6/23/20/6) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Patricia Feeley PF Northeast Brokerage Inc PHCN o E . (845)223-8107 FAX No):( 845)227-8816 27 High Ridge Road ADDRESS:pfeeley@pfnortheast.com INSURERS AFFORDING COVERAGE NAIC# Hopewell Junct3.on NY 12533 INSURER A:Harle sville Worcester Ins. Co. INSURED INSURER B: Custom Commercial Constuction Corp INSURER C: I INSURER D: 76 Brook Street INSURER E: Bay Shore NY 11706 INSURER F: COVERAGES CERTIFICATE NUMBER:CL166207303 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS INSR TYPE OF INSURANCE ADDL UBR POLICY NUMBER POLICY EFF MM/DD EXP LIMITS LTR R COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 DAMAGE TO A CLAIMS-MADE ❑X OCCUR PREMISES(Ea occurrence) $ 100,000 x Contractual Liability MPAS0729T 7/4/2016 7/4/2017 MED EXP(Any one person) $ 5,000 PERSONAL BADV INJURY $ 1,000,000 GEMLAGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 2,000,000 � PRO- POLICY F—]LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT Eaaccident $ 1,000,000 A X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BAB0727T 7/4/2016 7/4/2017 BODILY INJURY(Per accident) $ AUTOS AUTOS NON-OWNED PROPERTY DAMAGE X HIRED AUTOS X AUTOS Peracadent $ X UMBRELLA LIAB x OCCUR EACH OCCURRENCE $ 10 000 000 A EXCESS LIAB CLAIMS-MADE AGGREGATE $ 10,000,000 DED I R I RETENTION$ 10 000 CMB80728T 7/4/2016 7/4/2017 $ WORKERS COMPENSATION PH- AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE ❑ N/A E L EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory in NH) E L DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ I L DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space is required) Re: MCD 8850 Main Rd, Mattituck; Town of Southold is 3.ncluded as adda.tional insured in regards to license Permits issued to the named mnsured. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town Hall Annex Building ACCORDANCE WITH THE POLICY PROVISIONS. 54375 Route 25 P.O. BOX 1179 AUTHORIZED REPRESENTATIVE Southold, NY 11971 Patricia Feeley/PATTY ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD INS025 nm4mi New York State Insurance Fund Workers'Compensation&Disability Benefits Specialists Since 1914 8 CORPORATE CENTER DR,3RD FLR,MELVILLE,NEW YORK 11747-3129 Phone*(631)7564300 CERTIFICATE OF WORKERS' COMPENSATION INSURANCE ❑ ■ R ^^^^^^ 112256791 CUSTOM COMMERCIAL CONSTRUCTION CORP 76 BROOK STREET r BAYSHORE NY 11706 , ■ Scan to Validate POLICYHOLDER CERTIFICATE HOLDER CUSTOM COMMERCIAL CONSTRUCTION CORP TOWN OF SOUTHOLD 76 BROOK STREET TOWN HALL ANNEX BUILDING BAYSHORE NY 11706 54375 ROUTE 25-P O. BOX 1179 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER PERIOD COVERED BY THIS CERTIFICATE DATE 1646080-2 502590 07/26/2016 TO 07/26/2017 6/23/2016 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 646 080-2 UNTIL 07/26/2017, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY IF SAID POLICY IS CANCELLED,OR CHANGED PRIOR TO 07/26/2017 IN SUCH MANNER AS TO AFFECT THIS CERTIFICATE, 10 DAYS WRITTEN NOTICE OF SUCH CANCELLATION WILL BE GIVEN TO THE CERTIFICATE HOLDER ABOVE NOTICE BY REGULAR MAIL SO ADDRESSED SHALL BE SUFFICIENT COMPLIANCE WITH THIS PROVISION. THE NEW YORK STATE INSURANCE FUND DOES NOT ASSUME ANY LIABILITY IN THE EVENT OF FAILURE TO GIVE SUCH NOTICE THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND U DIRECTOR,INSURANCE FUND UNDERWRITING This certificate can be validated on our web site at https://www nysif com/cerUcertval.asp or by calling(888)875-5790 VALIDATION NUMBER:983537063 U-26.3 2016 COMMERCIAL REVISIONS - DRAWING I L - ,I Lj (9 _ T1 .0 Cover Sheet ALTERATION GN 1 .0 General Notes FREEZER „ „ GN2.0 General Notes a a a a ii n I� ;F� WOMEN'Sx� DINING BUILDING INFORMATI0N : ARCHITECTURAL COOLER " �_ ADDRESS: m Floor Plan D1 .0 De o ( � .e I O A1 .0 Floor Plan STATE SITE CODE: 031 -1745 A3.0 Details & Notes r- 6o MENS j STREET ADDRESS: 8850 MAIN ROAD SUPPOI T II CITY: MATITUK HANICAL & PLUMBING Li SUFFOLK W a ; STATE: NEW YORK M1 .0 Mechanical Plan M '_ _ I • P1 .0 Water, Waste & Vent Piping CUSTOMER ,0.1 ,,0.1 o. of SCOPE OF WORK: P1 .6 Overhead/Underground Rough-In SERVICE I_' -_ COMMERCIAL INTERIOR ALTERATION P4.0 General Notes ADDING AND RELOCATING KITCHEN EQUIPMENT KIOSK INSTALLATION ELECTRICAL FRONT COUNTER MODIFICATION --- -- - - `�r' E1 .0 General Electrical Notes t� STRUCTURE: E3.1 Power Plan Y 8" LOAD BEARING WALLS, STEEL ROOF FRAMING (EXISTING 1.0 REMAIN) E3.2 Electrical Rough-In Schedules W E4.1 Single Line & Schedules UTILITIES: ELECTRIC/GAS UTILITIES TO REMAIN KITCHEN EQUIPMENT KD Kitchen Demo � AFFECTED AREA BUILDING CODE: K1 .0 Kitchen Layout THIS DRAWING IS FOR BUILDING CODE EDITION: 2010 BUILDING CODE OF `SEW YORK STVi-.E- REFERENCE ONLY K2.0 Kitchen Equipment KEY PLAN MECHANICAL CODE EDITION: 2010 MECHANICAL CODE OF NEW YORK ".TATE K2.1 Kitchen Schedules N.T.S. ELECTRICAL CODE EDITION: NATIONAL ELECTRICAL CODE 2011 . PLUMBING CODE EDITION: 2010 PLUMBING CODE OF NEW YORK K2.2 Kitchen Elevations ,,MddIF,<'"', ENERGY CODE EDITION: 2012 INTERNATIONAL ENERGY CONSER` AFION CODE K2.3 Kitchen Notes Uj - Nnnech , rA,ddlc*ow.. N^x,.rl W/ 2014 SUPPLEMENT THE NYSECC KE1 .0 Kitchen Electrical Rough-In ::, N•r", ,a.,P„ FIRE/LIFE SAFETY CODE EDITION: 2010 FIRE CODE OF NEW YORK STATE KP1 .0 Kitchen Plumbing Rough-In u; Hamdo # • FUEL/GAS CODE EDITION: 2010 FUEL CODE OF NEW YORK STATE � °y LL r "r ;' - - 'i r`Vl,..,i.YIv - .- .N NeW`°{d U� ,. n1 HEALTH CODE EDITION: SUFFOLK COUNTY HEALTH CODE u Q New HaVen - F! n- tU-i o0 ,yh.onl. ,, [ R°,v?"'�'a �iRk^;"y�,c°•' V 1=o w ACCESSIBILITY CODE EDITION: ANSI Al 17.1 2009 AND 2010 NYSBC CH. 1 1h , f c� W� Tuz 6TWZ f?rid9epartl t:rw • DATE• .. �(..�, B.P.U #��:S,.n.�,. :�a w a a N BUILDING DATA: W �z -,.• Norwalk _..,s.,., .�..,. ..�.. '' to W 2 FEE:,.,,-,- BY:_ ,�? �� z ��o g OCCUPANCY: USE GROUP A2 (EXISTING TO REMAIN) °tioTlt=v ^'-'I DI'`,'a DEPARTMENT AT LU< CONSTRUCTION TYPE: 5B EXISTING TO REMAIN 765-1802 uF.".,1 TO 4PItF FOR THE �� w °W ( ) FCLLO'+V:NG I"SPECTIONS: x o nMwmRd RENOVATION TYPE: ALTERATION-2 1. FC.�N,D,1T70 N - TWO REQUIRED J , z NUMBER OF STORIES: 1 F0 : i J1 'r D CC''CRETE w .. - .: F.:ri Br,n,,hamp«'•i � ✓� /� r t ! � RI BUILDING HEIGHT: 17'-11 :: MAIN BLDG. PARAPET) (EXISTING TO REMAIN) 2. ROUGH - t FiAMING & PLU°:;E;;,'.G 0 O H,in L+nc tan n. Han<I,ton Esys INSULA ,• o '`' 25' 11 " HI 3. I . f`,TiON r . , EARTH ROOF CAP) (EXISTING 10 REMAIN) m ...[nn'. \;k " f ff 4. Fi?�I�',L - CONSTRUCTION MUST o w �o .,nlrlFf 17 -4 (ENTRY) EXISTING TO REMAIN) co�J�PLE ._ FOR c.o. _ ° Z� \..�Lon4 Wand _ r1 CH. 'I•C _ R - E_m GROSS BUILDING AREA: 3;06>0 GROSS S.F. (EXISTING TO REMAIN) ALL cor�sr `.UCTI,� -0 it rv�l=lwT ThR w U REQUIREMENTS OF THE:CODES OF(IEW a Q REQUIREMENTS C C r ,Ir n `m o el,..,, ► * EXISTING OCCUPANCY UNCHANGED STATE. NOT RESFo�isIPLE FOR D`SiGF1 OR COINISTRUCTION ERRGRS, o w LIFE SAFETY SYSTEM: o ° _. a L o O L O 0c a EMERGENCY LIGHTING: EXISTING TO REMAIN o.0 omO)D - :030 Q V) EXIT SIGNS: EXISTING TO REMAIN , SITE PANIC HARDWARE: EXISTING 'TO REMAIN c CODES OF 0 W% o � 3 N a FIRE ALARM AND SMOKE DETECTION SYSTEM: EXISTING TO REMAIN CU"-' `-' ` ' r► ,, °��` N1:W YJ7,K ST;-�`i E & TOWN CODES C � .. o r c: 0.- AS REQUIRED AND CONDITIONS OF o ' - U , ** ALL LIFE SAFETY SYSTEMS/COMPONENTS ARE EXISTING TO REMAIN o � o� o 0 1Z 0 hgOr1RD ( U �,a o DESIGNER OF R _n�TM�z� sG w �a,� T.�►��L�5 - SO o C) -j L - VICINITY MAP U Q :'- (n O'y C U O DISCIPLINE: NAME: ADDRESS: LICENSE #: O a N°0 o� E NORTH - '--- '- _ KENNETH 201 OCCUPANCY O o-Ea E MECHANICAL:IRAL: DAVID EIFFERKENIZIE, AIA 1700S. MAPLE AVENUE, SUI-fE WEST INDUSTRIAL DRIVE, SOU TEABB ROGERS, BAR 0272756 0926505 U � IS UNL, U o N �o ° o AWFUL vi -_ 0 N y C d . SYMBOL LPLUMBING: DAVID LEIFFER 1700 WEST INDUSTRIAL DRIVE: SUITE B, ROGERS, AIR 72756 092655 VVI T HOUT CERTIFICATE o T 3 o N ELECTRICAL: JOHN FERGUSON, PE 1700 WEST INDUSTRIAL DRIVE, �'iTE B, ROGERS, •'a.2 72756 085807 � �, 0 o D.N W ° OF OCCUPANCY w s 0� o o 1) s H o 3- C- to- 40 SECTION TAG (D DOOR TAG MCDONALD ' S CONSTRUCTION F` t1?. 0JEC­F MANAGER : wr0 (0 LO p}p p O m J o � U ct 5 DETAIL TAG DINING ROOM ROOM NAME & NAME: ADDRESS: - _ PHONE #: I�LUiv1BERCERTIFlCATIOj�I 3 Y N = w w a o 6.o i o3 ON LEAD.CONTENT BEFORE U) � I NUMBER (781) 686-6313 CERTIFICATEOFOCCUPAPICY o Q � M o C - / AREA CONSTRUCTION MANAGER: TESSA BERNSTEIN 111 WOOD AVENI..IE SOI.EH, SUITE arc, Ci T/ SLAB A ISELIN, NJ 08830 SOLDER USED IN WATER � CD " � ELEV. 0'-0" ELEVATION TAG PARTITION TAG CORE STATES GROUP PROJECT MANAGER : SUPPLY SYSTEP.l CANNOT EXCEED 2/10 OF 1%LEAD. 6 DETAIL NAME: ADDRESS PHONE #: 1. z DRAWING TITLE PLUMBING A4.0 1 1 /2 = 1 '-0" DETAIL NUMBER PROJECT MANAGER: ANDY LEE 201 S. MAPLE AVENUE, SUITE 300 (215) 449-2265 ALL PLUMBING WASTE AMBLER, PA 19002 alee@core-eng.com &WATER LINES NEED TES T kNIG PEFORE COVERING w g ALL CORRESPONDENCE SHALL BE DIRECTED SIRE I � CC '10 � c� o z TO CORE STATES GROUP PROJECT MANAGER RQUlRLD �EI � z w Ld o ~ � J Q w _ L � o w o 'o LL_ m w Q I- z � w o 0 0 0 Ln 00 W 4 w m z Q � 0 1= o W w Of : w o O X W 0 w M Ld r- N W o N o 031.1745.00.0 o z L5 IW 6 V) COVER KIOSK GUIDELINES GEIS � � R A L N OTE S CONSTRUCTION DOCUMENTS: TEMPORARY FACILITIES UTILITIES & CONTROLS: GENERAL REQUIREMENTS 1. BY EXECUTION OF THE CONSTRUCTION CONTRACT, THE CONTRACTOR REPRESENTS 1. PROVIDE BARRIERS, FENCES AND OTHER CONTROLS TO PREVENT PUBLIC ENTRY TO THAT HE OR SHE HAS (1) READ AND UNDERSTANDS THE REQUIREMENTS OF THE CONSTRUCTION AREAS, AND TO PROTECT CONSTRUCTION WORKERS AND THE PUBLIC CONSTRUCTION DOCUMENTS, (2) VISITED THE PROJECT-SITE, (3) BECOME FAMILIAR FROM HAZARDS OF CONSTRUCTION. WITH THE LOCAL CONDITIONS UNDER WHICH THE WORK WILL BE PERFORMED, (4) SINGLE CORRELATED PERSONAL OBSERVATIONS WITH REQUIREMENTS OF THE CONTRACT 2. PROVIDE PROTECTION OF CONSTRUCTION MATERIALS FROM LOSS, DAMAGE, FIRE OR SIDED KIOSK OTHER KIOSK PLACEMENT DOCUMENTS, AND (5) THAT HE OR SHE WILL COMPLY WITH ALL REQUIREMENTS OF THEFT, AND PROTECT EXISTING CONSTRUCTION FROM DAMAGE BY CONSTRUCTION CONFIGURATION: PARALLEL KIOSK CAN BE ANGLED AND/OR FREE FLOATING THE CONSTRUCTION DOCUMENTS. OPERATIONS. GENERAL NOTES: 2. THE INTENT OF THE CONSTRUCTION DOCUMENTS IS TO INCLUDE ALL ITEMS 3. PROVIDE TEMPORARY FIRE-PREVENTION MEASURES AND PROCEDURES INCLUDING z -TYPICAL KIOSK QUANTITY (4), FINAL QUANTITY PER RESTAURANT TO BE FIRE-EXTINGUISHERS PER AHJ REQUIREMENTS. 0 NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE CONSTRUCTION DETERMINED BY MCDONALD'S OPERATIONS TEAM AND ACM WORK - AND TO PROVIDE (FURNISH AND INSTALL) ALL PRODUCTS, MATERIALS, EQUIPMENT OR ACCESSORIES REQUIRED FOR PROPER OPERATION, IN ACCORDANCE 4. PROVIDE DUMPSTERS AND COLLECT WASTE DAILY. DISPOSE OF MATERIAL IN A v -12'CLEAR DIMENSION HIGHLY RECOMMENDED BETWEEN FRONT WITH THEIR MANUFACTURER'S REQUIREMENTS. LAWFUL MANNER. PLACE DUMPSTER IN LOCATION APPROVED BY OWNER OR cn COUNTER AND KIOSK *EXISTING CONDITIONS TO BE CONSIDERED LANDLORD, AS APPLICABLE. w -SEE PUCK HOLDER GUIDELINE FOR PLACEMENT 3. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY - WHAT IS REQUIRED BY ONE 0 GENERAL PRODUCT REQUIREMENTS 3W-0 SHALL BE AS BINDING AS IF REQUIRED BY ALL. WHILE PREPARED WITH DUE CARE MIN -WALL FINISH BEHIND KIOSK TO COORDINATE WITH DECOR AND DILIGENCE, PERFECTION IS NOT POSSIBLE. DESIGN AND CONSTRUCTION ARE 1. STORE PRODUCTS PER MANUFACTURER'S INSTRUCTIONS, PROTECTED FROM DAMAGE COMPLEX - EVERY POSSIBLE CONDITION OR CONTINGENCY CANNOT BE ANTICIPATED -POWER FROM ABOVE (WITH STANDARD CEILING HEIGHT) IF CEILIING IS OR FULLY INDICATED WITHIN THE DOCUMENTS. OR ABUSE, AND WITH VENTILATION TO AVOID CONDENSATION. 32•x48•CLEAR GREATER THAN 10'-6" CONTACT USRD PROJECT MANAGER, SEE KIOSK SPACE IN FRONT 4. CAREFULLY STUDY AND COMPARE THE VARIOUS DRAWINGS (INCLUDING BUT NOT 2. APPLICATION OF A MATERIAL OR EQUIPMENT ITEM TO WORK INSTALLED BY OTHERS OF KIOSK FACEFM CUT SHEET FOR ADDITIONAL ELECTRICAL INFORMATION LIMITED TO ARCHITECTURAL STRUCTURAL, CONSTITUTES ACCEPTANCE OF THAT WORK AND ASSUMPTION OF RESPONSIBILITY FOR AL MECHANICAL OR ELECTRICAL AND OTHER o -CONSIDER SIZE OF BASE PLATE FOR CLEARANCE WHEN ANGLING A KIOSK CIF q, Fl�llONTRACT DOCUMENTS WITH THE EXISTING CONDITIONS AT THE PROJECT-SITE SATISFACTORY INSTALLATION AND PERFORMANCE. AGAINST AWALL/PARTITION BEFORE STARTING CONSTRUCTION. REPORT ERRORS, INCONSISTENCIES OR OMISSIONS 3. INSPECT EACH ITEM OF DISCOVERED FOR CLARIFICATION. THE CONTRACTOR WILL BE RESPONSIBLE FOR MATERIAL OR EQUIPMENT IMMEDIATELY PRIOR TO -KIOSK MAY BE TURNED ON AN ANGLE TO INCREASE SCREEN VISIBILITY REPAIR OR CORRECTION COSTS IF WORK IS EXECUTED WITH KNOWLEDGE THAT IT INSTALLATION. REJECT DAMAGED AND DEFECTIVE ITEMS. z'-e• -DOUBLE SIDED OR SINGLE SIDED KIOSKS CAN BE FREE FLOATING OR INVOLVES AN ERROR, INCONSISTENCY OR OMISSION - WITHOUT THE ABOVE NOTICE. 4. COORDINATION WITH FIXTURES, FURNISHINGS & EQUIPMENT (FF&E): MIN ANGLED w 3 • 5. IN THE EVENT OF CONFLICT OR AMBIGUITY WITHIN THE CONSTRUCTION DOCUMENTS, 5. REVIEW THE OWNER'S SEPARATE CASEWORK/FIXTURES, FURNISHINGS, EQUIPMENT, & Q MINFRONT ELEVATION -WHEN SPACE ALLOWS, THIS SOLUTION IS THE ULTIMATE IN INTERRUPTING THE CONTRACTOR WILL BE DEEMED TO HAVE AGREED TO PROVIDE THE GREATER SIGNAGE DRAWINGS FOR UNIT SIZES, WEIGHTS, SERVICE-CONNECTIONS AND CUSTOMERS AND IDEAL WHEN LARGE GROUPS ARE EXPECTED TO ORDER QUANTITY AND / OR BETTER QUALIT`, OF MATERIALS AND / OR WORK. OMISSIONS IN CLEARANCES REQUIRED - WHETHER FURNISHED OR INSTALLED BY THE CONTRACTOR SIDE ELEVATION FRONT ELEVATION PLAN VIEW TOGETHER 3M" THE DESCRIPTION OF THE WORK DO NOT RELIEVE THE CONTRACTOR FROM OR OTHERS. VERIFY THAT REQUIRED ROUGH-INS, CONNECTIONS AND CLEARANCES w • PROVIDING A COMPLETE PROJECT. WILL BE PROVIDED. PROVIDE OPENINGS AND DELIVERY ACCESS FOR FF&E ITEMS, -ENSURE ADEQUATE CIRCULATION AROUND FREE FLOATING KIOSKS AND PROVIDE STAGING SPACE FOR THEIR INSTALLATION. REPORT DISCREPANCIES OR GENERAL NOTES: ° ° ° ° 0 -IDEAL WHEN A LARGE QUANTITY OF KIOSK FACES ARE REQUIREID GENERAL SCOPE OF WORK: OMISSIONS OF EQUIPMENT REQUIREMENTS PRIOR TO INSTALLATION. -TYPICAL KIOSK QUANTITY (4), FINAL QUANTITY PER RESTAURANT TO BE 32•x48•CLEAR 1. PERFORM ALL CONSTRUCTION WORK INDICATED OR OTHERWISE REQUIRED FOR 6. PROVIDE ALL HVAC, PLUMBING, GAS OR ELECTRIC SERVICE CONNECTIONS TO SPACE IN FRONT COMPLETION OF THE PROJECT - EXCEPT AS NOTED OTHERWISE. / DETERMINED BY MCDONALD'S OPERATIONS TEAM AND ACM OF KIOSK FACE CASEWORK FIXTURES, SIGNAGE, OR EQUIPMENT INDICATED WHETHER UNITS ARE INSTALLED BY CONTRACTOR OR BY OTHERS). 2SCHEDULE AND COORDINATE I �"1 - L . ATE THE WORK OF THE COMPLETE PROJECT TO ASSURE AN R DIMENSION HIGHLY RECOMMENDED BETWEEN FRONT L' COUNTER AND KIOSK *EXISTING CONDITIONS TO BE CONSIDERED GENERAL EXECUTION OF THE WORK -SEE PUCK HOLDER GUIDELINE FOR PLACEMENT P EFFICIENT AND ORDERLY SEQUENCE OF INSTALLATION OF ALL ELEMENTS - WITH PROVISIONS FOR ACCOMMODATING ITEMS TO BE INSTALLED LATER. U, ;�,\ 1 1. ESTABLISH AND MAINTAIN DURABLE MARKERS TO LOCATE ALL ELEMENTS OF THE —WALL FINISH BEHIND KIOSK �'-8•� 3. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR CONSTRUCTION MEAN WORK, INCLUDING BUT NOT LIMITED TO S, METHODS, PARTITIONS, CASEWORK, FIXTURES, TO COORDINATE WITH DECOR TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS EQUIPMENT AND LIGHT-FIXTURES, AND THEIR RELATED MECHANICAL, ELECTRICAL AND PLAN OF THE WORK. PLUMBING CONNECTIONS. o —POWER FROM ABOVE (WITH STANDARD CEILING HEIGHT) IF CEILING IS / GREATER THAN 10 CONTACT USRD PROJECT MANAGER, SEE KIOSK CUT SHEET FOR ADDITIONAL ELECTRICAL INFORMATION 4. PROVIDE ALL REQUIRED NOTICES FOR INSPECTIONS AND APPROVALS OF THE WORK 2• AT PROJECTIONS OF FINISHED SURFACES, INCLUDING PILASTERS OR THICKENED BY THE AUTHORITY HAVING JURISDICTION (AHJ). THE MOST RESTRICTIVE CODE WALLS, RETURN ALL EXPOSED SURFACE FINISHES BACK TO THE PRIMARY SURFACE ` _y. ' z - -CUSTOMER QUEUES MAY FORM AND CREATE CONGESTION WITH REQUIREMENTS AS INTERPRETED BY LOCAL OFFICIALS WILL APPLY. EVEN IF NOT SPECIFICALLY NOTED. Lu Z o OTHER ORDER POINTS. USE THIS CONFIGURATION ONLY WHEN THERE IS �w Wad SUFFICIENT CLEAR SPACE IN FRONT OF KIOSK 5. VERIFY LOCATIONS OF EXISTING UTILITY SERVICE CONNECTIONS SERVING THE 3. PERFORM ALL CUTTING, PATCHING AND FITTING TO ACCOMMODATE CONSTRUCTION Z <wo PROJECT BEFORE STF.RTING CONSTRUCTION. LOCATIONS OF EXISTING UTILITIES NOTED WORK AND TO ACHIEVE THE INTENT OF THE CONSTRUCTION DOCUMENTS. CUT & C� uj ARE APPROXIMATE, AND MAY BE BASED ON UN-VERIFIED INFORMATION. PROVIDE ALL PATCH PARTITIONS FOR INSTALLATION OF PLUMBING OR ELECTRICAL SERVICES AND w ow -WALL OR PARTITION NOT NECESSARILY REQUIRED BEHIND KIOSK, SINGLE FOR INSTALLATION OF WALL BLOCKING IF NECESSARY. PROVIDE ESCUTCHEONS SIDED CONFIGURATION ACTS AS A PARTITION CONNECTIONS REQUIRED AT UTILITY CONNECTION POINTS AT NO ADDITIONAL COST TO <'". p -SINGLE SIDED KIOSKS MAY BE ANGLED SLIGHTLY (10'-15') TO THE OWNER. GROMMETS AND SIMILAR SURFACE CLOSURE OR FINISHED TRIMS AT EXPOSED RATIONS OF FINISHED SURQ M 6. PROVIDE SUBCONTRACTORS WITH A FULL-SET OF THE CONSTRUCTION DOCUMENTS OVIDE BETTER SCREEN VISIBILITY PENETRATIONS FACES. TO ENSURE COORDINATION BETWEEN ALL TRADES AND EACH SUBCONTRACTOR. 4• BRACE PARTITIONS, SUSPEND CEILINGS OR SOFFITS, AND BRACE PLATFORMS, o -WORK WELL SIDE BY SIDE WITH A 5'WIDE PARTITION/WALL BEHIND PUCK DISPENSER SUSPENDED ITEMS OR SIMILAR CONSTRUCTION ONLY TO STRUCTURAL ELEMENTS m U E o N 7. ALL CONSTRUCTION WORK MUST BE OF GOOD QUALITY - FREE FROM DEFECTS AND ABOVE - EVEN IF NOT SPECIFICALLY NOTED. DO NOT ANCHOR TO ROOF DECK o w o LOCATION GUjQ (NIN ACCORDANCE WITH REQUIREMENTS OF THE CONSTRUCTION DOCUMENTS — OR THE PLUMBING / SPRINKLER PIPES, DUCTWORK, ELECTRICAL CONDUIT OR SIMILAR a = m coZ GENERAL NOTES WORK MAY BE CONSIDERED DEFECTIVE — AND SUBJECT TO CORRECTION OR ELEMENTS. � cl 2cFa REPLACEMENT BY THE CONTRACTOR WITHIN A PERIOD OF ONE (1) YEAR AFTER Q —FLUSH MOUNT PUCK DISPENSER PER KIOSK FACE —BOTTOM OF SINGLE PUCK DISPENSER SHOULD NEVER BE LOWER THAN 27" AFF SUBSTANTIAL COMPLETION. COORDINATION WITH ADJACENT CONSTRUCTION: -TOP OF PUCK DISPENSER NEVER HIGHER THAN 48" AFF INSTALLATION OF OWNER-FURNISHED PRODUCTS: 1. LIMIT WORK TO OCCUR WITHIN THE PROJECT SITE, OR WITHIN OTHER AREAS o E DESIGNATED OR APPROVED FOR USE BY THE OWNER / LANDLORD / OR -�'20 c,- 00. c" PUCK LOCATION 'A' RECEIVE AT SITE VERIFY RECEIPT HANDLE STORE ON-SITE (IF DEVELOPER. CONNECT TO EXISTING UTILITY SERVICES BEYOND THE PROJECT-SITE IN a a o o s 1. COORDINATE, THE MOST EXPEDITIOUS MANNER POSSIBLE WITH MINIMAL DISTURBANCE OF EXISTING " a ° LE SIDED KIOSK -HME FLUSH MOUNT PUCK DISPENSER REQUIRED), PROTECT AND INSTALL OWNER-FURNISHED PRODUCTS, AND PROVIDE P ` a)D 20-6 ° —KIOSK PARALLEL TO WALL SERVICE CONNECTIONS AS APPLICABLE. ELEMENTS OR FINISHES. a `o °t° 2 o CONFIGURATION: PERPENDICULAR TO WALL/PARTITION MULTIPLE UNITS -PUCK DISPENSER To BE MOUNTED ON THE WALL OR L c PARTITION BEHIND THE KIOSK 2. RESTORE ALL AREAS OF EXISTING LANDSCAPING (INCLUDING SPRINKLER SYSTEMS o ,, o a 3 N 'Q� -PUCK LOCATOR TO ALWAYS BE MOUNTED 4" TO THE 2. NOTIFY THE OWNER WITHIN FIVE (5) DAYS OF RECEIPT OF ANY ITEMS ARE MISSING ) DISTURBED DURING CONSTRUCTION TO ITS ORIGINAL CONDITION. 0 ° c: ` 0 RIGHT OF THE KIOSK IF SPACE ALLOWS DAMAGED OR OTHERWISE DEFECTIVE. LACK OF NOTIFICATION WILL BE CONSIDERED ' �, *DISPENSER MAY BE MOUNTED EITHER DIRECTLY TO PRESUMPTIVE PROOF THAT ALL ITEMS DID ARRIVE UNDAMAGED AND IN PROPER ♦ I: o .'o KIOSK OR TO WALL BEHIND KIOSK QUANTITIES, AND ANY REPLACEMENT OR REPAIRS NECESSARY WILL THEN BE THE FINAL CLEANING: o d - ° ° S ° RESPONSIBILITY 0�- THE CONTRACTOR. C14� ° ° ° t 1. JUST BEFORE OWNER OCCUPANCY, CLEAN ALL SURFACES INCLUDING FIXTURES AND -" 0 °c" _ PRODUCTS CAUSED BY CONSTRUCTION EQUIPMENT FOR THE OWNER'S USE AND OPERATION. POLISH GLASS AND PLUMBING V) o 0 0 � 0 0 3. REPAIR DAMAGE TO OWNER-FURNISHED FIXTURES TO BE WITHOUT NOTICEABLE STREAKS. VACUUM CLEAN FLOORS AND DAMP � °' � o.:I Fn E OPERATIONS TO THE OWNER'S SATISFACTION. W ° ° , E 0 IPE WALLS, FIXTURES AND EQUIPMENT - °.� x T TO BE DUST FREE WITHOUT STAINS, FILMS N ° o AND OTHER DISTRACTING SUBSTANCES. U ° N PLAN VIEW g �� � 2o - ° IL O J ,2 ° p 2. CLEAN THE PROJECT SITE OF RUBBISH, LITTER AND OTHER FOREIGN SUBSTANCES. `' a ° ID BROOM CLEAN PAVED AREAS AND REMOVE STAINS, SPILLS AND OTHER FOREIGN u D `� ° ID Fl� FRONT ELEVATION FRONT ELEVATION DEPOSITS. RAKE GROUNDS THAT ARE NEITHER PAVED NOR PLANTED, TO A SMOOTH ® "•v s ° ° 0 0 O U 0•V EVEN-TEXTURED SURFACE. � o ' �, �, 0 c: U PUCK LOCATION B Ud// v� v �.� o �, o-°v —HME FLUSH MOUNT PUCK DISPENSER v »_ v a� —KIOSK PERPENDICULAR TO WALL 7'-0 0 '3 w '3.� v MIN —PUCK DISPENSER TO BE MOUNTED DIRECTLY TO o ® 0 T 3 0 o P O P _'p v7 C KIOSK, BACK TO BACK Q a o U.N v v o —DISPENSERS SHOULD ALWAYS BE MOUNTED ON KIOSK L N ID ELEVATION FRONT ELEVATION w t 0•- D o s t SIDE CLOSEST TO THE WALL ui � 3 w c Q) N a 8' m D O m -� bi O W N o o m o _ w N 'n Q N ' O z U � w cn \ � N _ I �32'x48'CLEAR a O J Y �cn w � w a U N ¢ \ (j0 4'-0' 7' 0• I � Q CC CO MIN SPACE IN FRONT Y (n V) OF KIOSK FACE 4'-0• (n � O U NOTE: CLEAR PLAN VIEW PLAN VIEW cArOOiNo�OVERLAP N n• rn GENERAL NOTES: -TYPICAL KIOSK QUANTITY (4), FINAL QUANTITY PER RESTAURANT TO BE FRONT ELEVATION z DETERMINED BY MCDONALD'S OPERATIONS TEAM AND ACM Y U —12'CLEAR DIMENSION HIGHLY RECOMMENDED BETWEEN FRONT COUNTER AND KIOSK *EXISTING CONDITIONS TO BE CONSIDERED —SEE PUCK HOLDER GUIDELINE FOR PLACEMENT —WALL FINISH BEHIND KIOSK TO COORDINATE WITH DECOR a ZO F_ N -POWER FROM ABOVE (WITH STANDARD CEILING HEIGHT) IF CEILING � Z IS GREATER THAN 10'-6" CONTACT USRD PROJECT MANAGER, SEE KIOSK z w z CUT SHEET FOR ADDITIONAL ELECTRICAL INFORMATIONbj J � v L� w —IDEAL WHEN PLACED IN FRONT OF' THE SERVICE AREA, LESS LIKELY TO Q c cy- � O w o 'v INTERFERE WITH FRONT COUNTER QUEUING LL_ m w Q -IDEAL WHEN TRYING TO CAPTURE (CUSTOMERS FROM TWO ENTRANCES I- Ll w o Ow J O N 00Q w -LEVERAGES EXISTING DECOR ELEMENTS TYPICALLY SEEN IN OUR STANDARD z 00 � z z DECOR LAYOUTS (_0F_ a [if oLo -THIS IS THE PREFERRED PLACEMENT CONFIGURATION — - mi 0- LLI 0 W w w r� 1= o cn 0- 031.1745.00.0 o Ep' z G NA ON bi N GENERAL NOTES GENERAL MOTES NEW YORK METRO SPECIFICATIONS New York Metro Specifications Type Finish Code Product Supplier Contact Product/Spec Number Color/Finish Notes Wallcovering TBD Wallcovering DL Couch Mollie Grojean 800.433.0790 ASL-161527/NA-17-MC181 Versa Midtown Portland Wallcovering TBD Wallcovering DL Couch Mollie Grojean 800.433.0790 ASL-161370/NA-17-MC180 Versa Midtown Seattle Z O Wallcovering TBD Wallcovering DL Couch Mollie Grojean 800.433.0790 ASL-161135/NA-17-MC182 Versa Midtown Philadelphia 1— Tile TBD Tile Eurowest Charleen Keuilian 800.978.7500 or Jan Deter 714.309.9551 IRG1224130 Ecocrete Sage 12"x 24"Main Floor Tile.GT02 0' U Tile TL24 Tile Crossville Frank Galifianakis,404.680.3691,e:fgalifianakis@crossvilleinc.com Structure-AV224 Timber 12"x24" w Tile TL25 Tile Dal-Tile Fred Davis,972.423.5464,e: Fred.Davis@daItile.com Veranda-Gravel 13"x20" Tile TL27 Tile Eurowest Charleen Keuilian 800.978.7500 or Jan Deter 714.309.9551 E-Wood R11-Blonde 6"x36"Accent Floor Tile.Accent tile behind RR nnirror Tile TL28 Tile Eurowest Charleen Keuilian 800.978.7500 or Jan Deter 714.309.9551 E-Wood R11-Oak 611x36" Tile TL29 Tile Eurowest Charleen Keuilian 800.978.7500 or Jan Deter 714.309.9551 E-Wood R11-Grey 61106" Tile TL04 Tile Eurowest Charleen Keuilian 800.978.7500 or Jan Deter 714.309.9551 Feel-Orange Taste 10"00" Tile TL05 Tile Eurowest Charleen Keuilian 800.978.7500 or Jan Deter 714.309.9551 Feel-Red Taste 10"x30"(2 week lead time),4"x12"(2 week lead gime) Tile TL08 Tile Eurowest Charleen Keuilian 800.978.7500 or Jan Deter 714.309.9551 Feel-Green Taste 10"x30" Tile TL22 Tile Eurowest Charleen Keuilian 800.978.7500 or Jan Deter 714.309.9551 Feel-White Taste 10"x30" Tile TL16 Tile Eurowest Charleen Keuilian 800.978.7500 or Jan Deter 714.309.9551 Architect Factory 12"x24".RR main wall,Center Island tile LLi Q Rovere-Tundra 6"x48"-used as an alternate to laminate wall Tile TL38 Tile Eurowest Charleen Keuilian 800.978.7500 or Jan Deter 714.309.9551 Legni paneling Tile TBD Tile Dal-Tile Fred Davis,972.423.5464,e: Fred.Davis@daltile.com Forest Park Timberland fuse grout GT08 w Paint PT02 Paint Benjamin Moore http://www.benjaminmoore.com OC-27 Balboa Mist Restroom Ceilings Paint PT06 Paint Benjamin Moore http://www.benjaminmoore.com 2134-30 Iron Mountain Stall Door Frames. Paint PT27 Paint Benjamin Moore http://www.benjaminmoore.com 2106-20 Auberge Door Frames Paint PT39 Paint Benjamin Moore http://www.benjaminmoore.com 2146-30 Split Pea Painted Soffit '� p f�f�� J Paint PT04 Paint Sherwin Williams http://www.sherwin-williams.com SW 6866 Heartthrob Painted Soffit 1 http://www.benjaminmoore.com TBD Paint Ben htt //www.benamin Moore aminmoore.com 2114-30 Desert Shadows Painted Soffit 1 j Paint TBD Paint Benjamin Moore http://www.benjaminmoore.com 2007-10 Smoldering Red Painted Soffit Laminate LM32 Laminate Wilsonart John Hill,254.718.7907,e:hillj@wilsonart.com 7938-38 New Age Oak Ceiling Elements Laminate LM50 Laminate Formica Carolina Ruf,513.678.3172,e:carolina.ruf@formica.com 8845-58 Bleached Legno Routed Laminate for use on walls Laminate LM51 Laminate Formica Carolina Ruf,513.678.3172,e:carolina.ruf@formica.com 8840-58 Natural Ribbonwood RR stall doors t„ U D_ �LLo Grout GT02 Grout Mapei Mapei 1.800.426.2734 Keracolor S 47 Charcoal 'W Z Grout GT08 Grout Mapei Mapei 1.800.426.2734 Keracolor S 10 Black use with menu board the Z =U Z Grout GT04 Grout Mapei Mapei 1.800.426.2734 Keracolor S 27 Silver use with taste tile at beverage center `" W W 0 Z QX0 800.723.1697 3/4"x 3"Red Oak Planks,2-8'Random Lengths, Welcome Wall-to have graphic applied and x (� W W P Wood TBD Red Oak 3/4"x 3"Select Grade Flooring Baird Brothers Sawmill e:info@bairdbrothers.com B603EM-OAK-2'_8'-SE-SANDED Square Edge, Unfinished Sanded ffinished with varnish listed below Z o W a LU Sherwin Williams,Water White Conversion Varnish, p Varnish TBD Varnish Sherwin Williams http://www.sherwin-williams.com V841`83 Dull Rubbed Effect;V84 F 83,5010-37808 Alkyd Finish for Red Oak Planks Z Q o Part#: Exterior:Gloss Black LU Y Townhouse Pendant Light Lighting L27LED Security Lighting 800.544.4848 SLSH-986114-991/CB8-991-SFL-FR/GU24/ Z o RLM Bowl Fixture/AKA Black Bowl Pendant Interior:Matte White wlens LM05010400 / /�� 0 m o Outside Shade:White W E o Lighting L05LED Large Drum Pendant Security Lighting 800.544.4848 Part#:LDP-00-308LED-BS Inside Shade:White ~ m co Mounting and Suspension:Brushed Steel - Shade:White Q U Li � o 0 e' 2 L r Lighting L24LED Oval Tapered Pendant Security Lighting 800.544.4848 Part#:LOP-00-208LED-BS a Q Mounting and Suspension:Brushed Steel Streamlline Pendant Light Finish:Metallic Silver o c Lighting L09 Security Lighting 800.544.4848 Part#:M-4-1DT8-CM48-OA-EU-ZT "o `� °0 Cylindrical Tube Light/AKA Linear Pendant Lens:Opal Acrylic — U) C: N .- Lighting TBD Casper(Beam Light Ar+ lightart.com 206.524.2223 White Opal Chroma °a .° o °'_� o °�' o 0 N 0 0 Lighting L01a GeneralDownlight/Cloud Soffit Downlight Security Lighting 800.544.4848 Part#:LB6LEDA10L35K9WH/DBXQL 6"LED Downlight,12.5W,White Trim GC to install in Cloud Soffit(soffit provided by ISI) v J o a �'0 0 ** NOTE:Cloud o °' °' c a L O + o O a 0 Soffit above Front o .� o T) 3 ° E Q_ Service Counter is 08-1 Updated 3.24.16 �:2o supplied by ISI.GC - Q) 0 0 0 E•- c u> to install soffit and c0 -o o o.� a downlights. 0 0 0 3 0 c UO O C O C t —+ C 0 N p 0 0 0 C O s 0 O O C l/l++ U.O. d O C C (I o 0 �'U) U p C U O O O O 0— 0 N N U C N= N �y O J~C`.O- 0 0 •Y O U Q C O U 0 0 v � O O C N O Q U O C N O U C U N U) �.N'��. 0 a)•V c ® -cc0-0 0 0 0 O aW TE 0 0 :30 t0 7 O CD 0 U co CD a0 O �- O O � 0 w E 0 3 0 0 ° 0 P 0O Q U a _ n W t OL�- O N N F- a 3- c U) d ZVI wO cp Ln r Q '— m ow c~i �r M o 0 < D O w wN pV) N 7p0 Q Y cn = w � w � CL 0-1 LI) U aQ � � oc\O � U O N (.3 N 0) z Z U O W a Z f— N O C Z z WW z W D '0 o 00 J � U D O w o 'o L L_ it � a F— w z LL_ � 0 0 J W 00 LLJ z_ Z U Z OW W w p S O X w w L N LLJ o cn o 031 .1745.00.0 o z �, O N 2E" 0 N GENERAL NOTES m • z GC TO PREP 1= EXISTING WALL FOR RELOCATED MOP SINK cn w '2� L — \ 2 3 N.I.C. I I FREEZER I� II a a o II II II II 6 II II 0 qO I N.I.C. a 1 ii ii 1 WOMEN'S - - w 102 ,X� i o II II DINING II II II II •0 101 OfN.I.C. = COOLER ------, ---- Fl -- 110 / no IG — � ---------- -�L o ---------- 6O 1 N.I.C. SUPPORT MEN'S ® O 104 I I I 103 -------------- O ® C9D -------------------- -� GC TO PREP EXISTING ' Q�' _�__ ® OO'`WALL FOR NEW / " s. - v W RECESSED ELECTRICAL I ICL i u ___---- A " ��� CREW ROOM CD w� a PANEL, COORDINATE WITH / ELECTRICAL AND ACM 1 g i� / pop FOR FINAL LOCATION I 4 2 - ® w Q Z Li T Lu O C7 Q CUSTOMER ® z \ SERVICE ® ® Q s I 100 0 ! ! ! w I , . (KITCHEN I o 3 \_J 105 / 5 I r7 ® � } ~ E N ® -------- °� U L� 1 r� W t�v ,0; mZ� U ®0 ® o� (D - I /� E c Q � o / Lid=] SEATING LAYOUT c S EXISTING TO 0 0 / 3 I ,/ / REMAIN, U.N.O. `0 0 0� c .o / EXISTING KITCHEN EQUIPMENT I � ,. �v o L-o TO REMAIN UNLESS NOTED `"� — — — — — o 0 0-o 0 E a . o N �� = ----� OTH-ERWISE. SEE KITCHEN 3 U o ` p a o SHE(TS;_F�R ADDITIONAL INFO 7 PLgo 11 c o ami 3 o I I / # 0 0• � �i I I 0 0 0 0 0 0 / � r� �-- ------------ --------J O `�- U�_ D c o'a L- c o o 0 c o c� 3 0 c pL in. c ,cn p O O U O p C O .L-• L �+ N O c N w U O a O C C+• (/1 N O D.N E C O CU C O N O p p++ X_ _ N N U C N L O U N -1 C "01 U N � O N p N C 0 co) O U c aL U m O w U a U r d � N O O N E � L I ` U C O V7 7 O wO 3 w 0'c: c O'3 v 0 3 0 0 0 0 0 ® -0 >. -t'-0 0 c w 0. Q' N N =O ( y N U 1 DEMO FLOOR PLAN a � o- `— Q'z all of F- 0_3w c. rn d D1.0 1 /4 = 1 '-0" ztkz Lo m o O m -j � O w � GENERAL DEMO NOTES DEMO CEILING NOTES SYMBOL LEGEND Z w " Q N � 00 NOT ALL APPLICABLE NOT ALL APPLICABLE Y L W a N 1. THE EXTENT OF THE CEILING WORK IS LIMITED BY THE O KEY NOTE - NOT ALL APPLY 0 Q N o 1. THESE DRAWINGS WERE PREPARED BASED ON INFORMATION ATTAINED FROM A SITE SURVEY. CONTRACTOR 8. CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING AS REQUIRED TO MAINTAIN STRUCTURAL STABILITY O v TO VERIFY ALL EXISTING CONDITIONS IN FIELD PRIOR TO DEMOLITION & NOTIFY THIS OFFICE IN CASE OF OF THE EXISTING STRUCTURE DURING ALL PHASES OF CONSTRUCTION. rITEMS NOTED ON THE FLOOR PLAN AND REFLECTED cn LI�IJ NEW/RELOCATED EQUIPMENT N DISCREPANCIES ASAP. DEMOLITION IS TO BE EXECUTED SO AS NOT TO DISTURB EXISTING STRUCTURAL & CEILING PLAN UNLESSNOTED OTHERWISE ROOFING SYSTEMS, AND OTHER AREAS THAT ARE INTENDED TO REMAIN INTACT. VERIFY ALL CONSTRUCTION TO gPROTECT FROM DAMAGE DURING CONSTRUCTION ALL EXISTING WALLS, FLOORS, CEILINGS, ETC. THAT ARE TO 2. ALL LIGHTS, DIFFUSERS, AND ANY OTHER EXISTING . BE REMOVED THAT IS NOT INTEGRAL TO STRUCTURAL SYSTEM PRIOR TO DEMOLITION. REMAIN. CONTRACTOR TO PATCH & REPAIR ANY DAMAGED PORTIONS OF THE EXISTING BUILDING AS REQUIRED CEILING COMPONENT IS TO BE REMOVED AND DENOTES ITEMS TO BE DEMO TO MATCH THE EXISTING ADJACENT CONSTRUCTION & FINISHES. RELOCATED PER THE ARCHITECTURAL, MECHANICAL, ALL DIMENSIONS SHOWN AS EXISTING SHOULD BE FIELD VERIFIED BY CONTRACTOR PRIOR TO DEMOLITION. PLUMBING AND ELECTRICAL PLANS UNLESS NOTED z OTHERWISE. VERIFYCONSTRUCTION.ALLDEMOLITION WORK W/ NEW CONSTRUCTION & INSTALLATION DRAWINGS PRIOR TO BEGINNING 10. THIS PLAN INDICATES A GENERAL SCOPE OF WORK TO BE PERFORMED AND DOES NOT RELIEVE THE 3ALL FINISHES TO MATCH EXISTING UNLESS NOTED DEMOLITION KEY NOTES CONTRACTOR TO COMPLETE THE BUILDING MODIFICATIONS AS SHOWN AND REQUIRED BY THE CONTR .ACT OTHERWISE. PLEASE COORDINATE ANY NEW FINISHES NOT ALL APPLICABLE o 3. DEMOLITION CONTRACTOR TO COORDINATE & REVIEW ALL CONSTRUCTION DOCUMENTS & DETERMINE THE DOCUMENTS, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL & HVAC WORK. WITH THE McDONALDS AREA CONSTRUCTION MANAGER 1 REMOVE WALL AND PREPARE ALL EXPOSED O EXTENT OF DEMOLITION WORK & BECOME FAMILIAR WITH THEM THOROUGHLY BEFORE PERFORMING ANY 11. IF CONTRACTOR ENCOUNTERS ANY HAZARDOUS MATERIALS DURING DEMOLITION OR CONSTRUCTION, PRIOR TO INSTALLATION SURFACES AND STRUCTURE FOR APPLICATION DEMOLITION HE OF FINISH SUBSTRATE DEMOLITION WORK. BY THE ACT OF STARTING DEMOLITION, THE CONTRACTOR WILL BE DEEMED TO HAVE SHALL IMMEDIATELY SUSPEND WORK & NOTIFY THE MCDONALD'S AREA CONSTRUCTION MANAGER BEFORE w COMPLIED WITH THE FOREGOING, TO HAVE ACCEPTED SUCH CONDITIONS, AND TO HAVE MADE THE NECESSARY PROCEEDING. O REMOVE AND REPAIR EXISTING FLOOR TO >- ALLOWANCES IN PREPARING HIS BID. 2 ACCEPT NEW FLOOR FINISH AS A RESULT OF Q 12. ALL DEMOLITION SHALL BE CARRIED OUT IN A SAFE MANNER & IN STRICT ACCORDANCE WITH OSHA DEMO OR NEW CONSTRUCTION. SEE 0 z " 4. ELECTRICAL DEMOLITION NOTE: REFER TO ELECTRICAL DRAWINGS FOR DETAILED ELECTRICAL DEMOLITION ARCHITECTURAL PLAN. z. wNOTES. z _ w 13. THE SUB-CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF DEMOLITION. THE WORK INCLUDES, BUT IS NOT O REMOVE KITCHEN EQUIPMENT - SEE KITCHEN p 5. VERIFY DISPOSITION OF ALL FURNISHINGS, MILLWORK, LIGHTING FIXTURES, ETC. TO BE REMOVED W/ OWNER. LIMITED TO THE DEMOLITION AND REMOVAL OF ANY WALLS, COUNTERS, FURNITURE, BULKHEADS, DOORS, PLANS FOR FINAL LOCATION J j b 0 w 0 0 ALL ITEMS TO BE DISPOSED SHALL BE DISPOSED OF OFF-SITE AND IN AN EXPEDITIOUS MANNER. PLUMBING, MECHANICAL AND ELECTRICAL ITEMS INCLUDING CONDUITS AND DUCTWORK AS SHOWN ON THE EXISTING FRONT COUNTER TO BE MODIFIED Lim w �0 � DRAWINGS OR AS REQUIRED TO COMPLETE THE INSTALLATION OF THE NEW WORK FOR A COMPLETE JOB. 4 6. ROOFING CONTRACTOR TO FIELD INSPECT EXISTING ROOF FOR WEATHER TIGHTNESS & PROPER DRAINAGE TO MEET SEEQ REQUIREMENTS. ? 0 N 00 00 PRIOR TO BID. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF EXISTING ROOF CONDITION 14. REMOVE ANY SINKS, WATER CLOSETS, URINALS, LAVATORIES, FLOOR DRAINS, NOTED ON DRAWINGS AS WELL Ld 0 CD a ``' AND FOR INCLUDING ANY NECESSARY REPAIR COSTS IN BID. WHEN APPLICABLE PER PROJECT SCOPE AS ALL ASSOCIATED PLUMBING ACCESSORIES. CAP, O5 EXISTING VALANCE TO REMAIN. Lo ( ) PLUG ALL ABANDONED SUPPLY & WASTE LINES' PATCH & o � w SEAL ALL FLOOR PENETRATIONS. SEE MECHANICAL & PLUMBING DRAWINGS FOR DETAILED DEMOLITION NOTES. _ 7. SAWCUT & REMOVE EXISTING SLABS AS REQUIRED FOR UNDERGROUND ELECTRICAL & PLUMBING LINES. GC TO PREP EXISTING WALL FOR NEW w O X 0 o x Ld REFER TO PLUMBING, ELECTRICAL & (KITCHEN DRAWINGS FOR ALL SAWCUTS & TRENCHING WORK REQUIRED. ALL 15. WHEN UTILITIES ARE REMOVED, CAP & SEAL A MINIMUM OF 8" BELOW FINISH FLOOR OR A MINIMUM OF 6" O DECOR WALL COVERING N LiJ wo N o CONCRETE FLOOR WORK TO BE FINISHED FLUSH WITH EXISTING FLOOR. DOWEL NEW SLABS TO EXISTING W/ ABOVE FINISH CEILING. 745.00.0 EXISTING DOOR, FRAME AND HARDWARE TO 031.1 #4 REBAR @ 24" O.C. EACH SIDE (STAGGERED). REBAR TO EXTEND 6" INTO EXISTING SLAB & ACROSS CUT EX O EX REMOVED. PATCH AND REPAIR OPENING o .1 OPENING. SECURE REBAR INTO EXISTING SLAB W/ EPDXY GROUT. REPLACE OR REPAIR ANY VAPOR BARRIERS AS REQUIRED. DISTURBED DURING EXCAVATIONS. (WHEN APPLICABLE PER PROJECT SCOPE) L u 0 ui N DEMO PLAN m z 0 0 cn w rl CP N.I.C. I II FREEZER ii ii — — — II II D II II IL II II II II I II II L u II I N.I.C. II II I WOMEN'S - - w u II . I � ii ii I 102 ,"�/ I o II —H DINING II II .o -- Floll > bi II II NEW RECESSED N.I.C. ELECTRICAL PANEL COOLER COORDINATE WITH 0 ELECTRICAL AND ACM 46 FOR FINAL LOCATION c�DE) N.I.C. F __1 SUPPORT I r I MENS ® 7'-5 104 I O y4 O' 0 O 103 5 I O V.I.F. ' L ® ------ ---------------------- --- ___.__ ' T,' { ' 9' O I Ll CB CREW ROOM I UFo wwz 1 9 D I 11 K ---------- 2 z . U Z I C 2 I LLJ w x x'__1 I -® O' OI Z Fro wx J i - U` wZ5 MT CUSTOMEfR O' O' U' O' 00 p ILL: U w - - I > z 11 F_ o SERVICE i ® ® < o 100 O 'O` [ w o ' I ` KITCHE'N. i iii ---- `------- o / . I ` J I 3 i ( ` m .. �,, U - `� w o 0- 0- C:� Q = m a OEM M I I '� 'O' o � �L II I 00 I 1 I ' 11 » ALL FINISHES TO MATCH ROOF DECKING „ --- I I 1 I ' 3 -1 6 DRILL DIABETW ENED ROD DOUBLE L ° ° ® I I 1 1 EXISTING UNLESS NOTED ° ° 111 V.I.F. U ° OTHERWISE - VERIFY AND 2x4 PROVIDE DOUBLE NUT & o o_' a)."6° a) C - - - - - COORDINATE WITH THE ACM 3" OVER-SIZED STEEL WASHER ` `_ ° -' -- '-' NEW KITCHEN EQUIPMENT �-� - a ° ° p c ° I ,-LAYOUT. SEE KITCHEN SHEETS ��- r--- v BOTH SIDES C) a CLO-0 °; ,FOR ADDITIONAL INFO I I < a 10d NAILS o ° N CAL I �; �� ; , zo °�° © 12 x O.C. 21 ROWS STAGGERED o 3 .�'o �_ 0 v 11 , QUARRY FLOOR = L ----� o _ > 0 N o ATTACHED TO BOTTOM CHORD OF o .N i I o TILE TILE - -� _- = o ° 0 0 0 0 - - - ® ¢ w Q ROOF JOIST (2 MIN.) °' a a I I `------- c: E ° o 1Z 1 I I FL # mac ° °.. - I I o o 0 0 0 0 r, J W W H O 4 Ute_ 1 1LZ Z N W ofo O �� 3 O p a) 0 o 0 OUTLET & JUNCTION BOX - SEE v0 " - c o ELECTRICAL LLoo ° ° oo cc C+ a N o,�',n E� c -PITp C U C o 0 0 CEILING AS SCHEDULEDy-r- c w s < U Q C V N 71 THREADED ROD TO PROJECT ° z BELOW CEILING TO RECEIVE d N ON.V C N U+�-• MONITOR BRACKET COVER 0 o ° E vi w/ 3" BEAUTY TUBE PROJECT �c c n. o o THRU CEILING 2 INCHES (,� ° o° ° °, a o NOTCH REAR SIDE OF BEAUTY IT jui C:E o (a_0 TUBE WITH 3/4" x 3" OPENING o 3 o c c°'.3 . o FOR CABLES AND WIRING. 0 3 0 ° o ° 0a � ° a�) o a' O N Q U dL j coN •U U N MONITOR BRACKET w s ° o o L Q)t F a3v cV) 1 FLOOR PLAN 3 MONITOR INSTALLATION DETAIL 1 �4 = � —� A1.0 m o0 oQ � 0 N.T.S . MB DIGITAL MENU BOARDS WITH BEZELS BY OTHERS UNDER SEPARATE a Y N w a o SYMBOL LEGEND PERMIT. SEE ELEC. PLANS. GENERAL NOTES SIMPSON o < o co N � V) STRONG-TIE GENERAL FINISH NOTES V' CEILING MOUNTED MONITOR: A) VERIFY MONITOR LOCATIONS WITH 1. ALL DIMENSIONS ARE TO FACE OF FINISH UNLESS OTHERWISE NOTED A PARTITION TYPE TAG SEE 2/A1.0 MT � "HTC4" © x McDONALD S PROJECT MANAGER PRIOR TO INSTALLATION. B) SEE 2. GC TO COORDINATE ALL REQUIRED BLOCKING FOR WALL HUNG EQUIPMENT, SHELVES, 48"O.C. I i < GC TO VERIFY AND COORDINATE THE FINISH NOTES WITH C4 ❑x KEY NOTE - NOT ALL APPLY DETAIL 4/A2.0 OR INSTALLATION METHOD ETC. FOR PROPER INSTALLATION HEIGHTS I I ? THE McDONALD'S AREA CONSTRUCTION MANAGER PRIOR KEY NOTES 3. ALL KITCHEN EQUIPMENT IS EXISTING TO REMAIN UNLESS NOISED OTHERWISE PLATE TOP I � STRUCTURAL MEMBER OR ASTENED TO BOTTOM HORD D TO STARTING CONSTRUCTION z ® DENOTES NEW WALL 4. ALL HAND SINKS, VEGETABLE AND 3 COMP SINK ARE EXISTINIG TO REMAIN U.N.O. 5. GC TO COORDINATE THE REMOVAL AND RELOCATION OF THE (KITCHEN EQUIPMENT WITH OF TRUSSES © 4'-0" O.C. 1. ALL FINISH SURFACES OF WALL AND CEILING MATERIALS SHALL BE CLASS B c❑ REFINISHED SEEQ FRONT COUNTER WITH WHITE CORIAN. THE KES AND ACM LATERAL '�� I AND SHALL HAVE A FLAME SPREAD RATING OF 26 TO 75 AND A SMOKE 6. REFERENCE THE KITCHEN PLANS FOR FINAL LOCATION OF THE KITCHEN EQUIPMENT BRACING TO i �>i CONT. RUNNER CHANNEL DENSITY OF 450 MAX. (PER CODE) ❑ 4"x4"x5'-0" HIGH STAINLESS STEEL CORNER GUARDS AT ALL EXPOSED LOCATIONS IN 7. GC TO COORDINATE ALL FINISHES WITH THE ACM STRUCT. ABOVE z FIRESTOPPING AT CEILING 2. DECORATIVE MATERIALS SHALL BE FLAME RETARDANT AND MEET THE Cc KITCHEN/SUPPORT AREA. CORNER GUARDS TO START AT FINISH FLOOR. ATTACH WITH WOOD SCREWS GENERAL DECOR NOTES 8 SUBSTRATE.PREPARE EXPOSED SURFACES AND STRUCTURE FOR APPLICATION OF FINISH ® 4-0" O.C. � i i 3. DCRITERIA ECORATIVE NFPA MATERIAL 1SHALL NOT CONCEAL EXITS, EXIT LIGHTS, ALARM INTO WOOD BLOCKING BULLNOSE COVE BASE WHERE TILE MEETS STAINLESS STEEL CORNER MTL. STUD PARTITION TYPE. w - GC TO VERIFY AND COORDINATE THE FULL DECOR SCOPE WITH THE 9. REMOVE ALL DEBRIS FROM BUILDING & SITE DISPOSE OF IN ACCORDANCE W/ STATE STATIONS, HOSE CABINETS, AND EXTINGUISHER LOCATIONS > cP CONCRETE EQMT PAD - EXISTING TO REMAIN 1/2 GYP BD McDONALD'S AREA CONSTRUCTION MANAGER PRIOR TO STARTING & LOCAL CODES. CLG AS 4. WHEN BUILDING TYPE IS A NON-COMBUSTIBLE CATEGORY, ALL PLYWOOD a ,n 1/2" CEMENT ALL PARTITIONS TYPE A UNLESS z L_ N WALL TILE COORDINATE WITH THE McDONALD'S AREA CONSTRUCTION CONSTRUCTION. GC TO FIELD VERIFY ALL DIMENSIONS PRIOR TO 10. PROVIDE TEMPORARY SUPPORT & BRACING AT ALL WALLS DURING DEMOLITION. SCHEDULED SHALL BE FIRE RETARDANT TREATED. o cT 11. ALL NEW HAND SINK LOCATIONS SHALL HAVE CEMENT BOARD BACKING 48" IN HEIGHT BOARD OR NOTED OTHERWISE 5 CD z r MANAGER FOR FINISHES ORDERING AND/OR INSTALLATION. PLYWOOD BACKUP a z A.F.F. EACH SIDE AS „ » 5.A. FRP OVER CEMENT BD BEHIND 3-COMP SINK TO HGT OF BACK SPLASH z w LJ DS DROPPED SOFFIT ABOVE - SEE REFLECTED CEILING PLAN - IF SEAT COUNT IS TO BE AFFECTED BY NEW DECOR LAYOUT, GC TO 12. ALL WOOD SHALL BE FIRE RETARDANT TREATED. INDICATED ON �A 3 5/8�� 5.B. FRP OVER 1/2" PLYWD IN KITCHEN AREA UNLESS OTHERWISE NOTED 0 a D w 0 VERIFY ANY AFFECTED SEATS AND NOTIFY ACM AND DECOR OF ANY FINISH SCHED „Al 3��5/8 W/BATT INS. (NOTE 4) - u FL FLOOR LINE - CHANGE IN MATERIAL IMPACT TO ACCESSIBLE SEATING. ACM AND DECOR TO VERIFY ALL DECOR SCOPE � „B 6„ 5.C. TILE WAINSCOT TO 6' A.F.F. OVER CEMENT BD. OVER EXT GRADE m � Q ACCESSIBLE SEATING REQUIREMENTS ARE MAINTAINED AND MODIFY BOTTOM 12 B1 = 6 W/BATT INS. PLYWOOD NOTE 4 AT MOP SINKS ILL_- z ,� < ORDERING KIOSK COORDINATE THE EXACT LOCATION WITH THE McDONALD'S AREA ACCESSIBLE SEATING IF NECESSARY DUE TO NEW DECOR LAYOUT. GC TO VERIFY AND COORDINATE THE FULL DECOR SCOPE OF BACKUP TO C = 8 "Cl"= 8 W/BATT INS. 6. PROVIDE CEMENT BOARD BACKER OR EQUIVALENT O - O n 4) K❑ CONSTRUCTION MANAGER. REFERENCE THE KIOSK AND PUCK GUIDELINES ON WITH THE McDONALD S AREA CONSTRUCTION MANAGER PRIOR U' ro BE CEMENT AT ALL TILE LOCATIONS. W Q ``' x SHEET GN1.0 - TOTAL SEAT COUNT: 70 TO STARTING CONSTRUCTION. GC TO FIELD VERIFY ALL BD. - MIDI. FLOOR AS SPACING: 16" O.C. 7. PROVIDE GYP BD SUBSTRATE IN DINING ROOM z zo 5 w � �-DENOTES NUMBER OF KIOSKS - ADA SEAT COUNT REQUIRED: 4 DIMENSIONS PRIOR TO ORDERING AND/OR INSTALLATION. Qo I- w 1/2 ABOVE SCHEDULED STUD GUAGE: TO BE PAINTED OR FOR V.W.C. AS APPLICABLE (n EROUGH-IN FOR FUTURE DIGITAL COMMUNITY BULLETIN BOARD AND NEXT - EXACT LOCATION OF ADA SEATS TO BE FIELD VERIFIED BY ACM. SLAB LOAD BEARING: 18L'i - a GENERATION INTERRUPT PANEL. COORDINATE EXACT LOCATION WITH M�:DONALD'S 1. NEW WALL COVERING PER DECOR DRAWINGS. ., ;'�. NON-LOAD BEARING: 20 W w w AREA CONSTRUCTION MANAGER. REFERENCE THE ELECTRICAL PLANS. En O CREW M LOCATION: 031.1745.00.0 • PLACE BULLETINBOARD AWAY FROM ANY TRAFFIC FLOW, FROM THE CREW INTERIOR PARTITION z 2A w e ROOM TV AND FROM CREW TRAINING AREA. 0 Al 0 • THIN MOUNT (<4" PROJECTION) ON FULL HEIGHT WALL WITH TOP OF 47" LG 3�4"= —O" tz N FLOOR PLAN BOARD MOUNTED AT 6'-8" AFF. m SCHLUTER ALIGN VALANCE WALL FINISHES WITH ACCENT WALL QUADEC Q100AE FINISHES. PROVIDE CONTINUOUS Y2" CEMENT BOARD AT OUTSIDE TILE OVER Y2" PLYWOOD ALONG ENTIRE VALANCE/WALL CORNER FOR TILE AND MENU BOARD INSTALLATION. B/ CEILING SEE RCP CT D Z O CT CT SCHLUTER D C QUADEC Q 100AE AT cn r — — — OUTSIDE TILE w IL _J1- - - - - - -L — — — — — — CORNER 0 T/FINISHED FLOOR LINE OF WALL BELOW ELEV. + 0'-0" IT QUARRY TILE COVE BASE I I 8._ —AHKol ALT: SCHLUTER DILEX „ r---—2_' V.I.F. —_JiiI I IIIiiI„IIIIii I I IIIiii L� REFINISHED FR ONT COUNTERTOP. FINIS H WITH WHITE CORIAN TO PER SEEQ I-A FRONT COUNTER ELEVATION REQUIREMENTS. > LLJ C — of COORDINATE ALL FINISHES WITH KEY NOTES "McDONALD'S ACM PRIOR TO INSTALLATION I II C I II I TOP OF COUNTER CT PORCELAIN WALL TILE: EUROWEST — ARCHITECT COLLECTION I i ii I C° 2'-10" COLOR: FACTORY SIZE 12"x24" PATTERN: STACK BOND A I C I n l GROUT: MAPEI 47 CHARCOAL —JOINT TO BE Ys,> MAX. I I ' n I - INTERMEDIATE COORDINATE WITH THE McDONALD'S AREA CONSTRUCTION MANAGER I I) D o UNDERCOUNTER / I SUPPORTS FURNISHED & INSTALLED BY KES CT NOT USED I B i G 1 I 5A II ` 1 CT CERAMIC WALL TILE: EUROWEST ❑ i �i A3.0 i ii 6 COLOR: TASTE SIZE: 10"x30" , u µ C GROUT: MAPEI 27 SILVER —JOINT TO BE Ys MAX. oQ LLp COORDINATE WITH THE McDONALD'S AREA CONSTRUCTION MANAGER W N Q" �au:o PORCELAIN WALL TILE: DAL—TILE, FOREST PARK TIMBERLAND I I II I �wz CT COLOR: WOOD PLANK SIZE: 6"x36" PATTERN: STACK BOND ( �� NEW DIGITAL �� r �0o D GROUT: MAPEI 79 COCOA —JOINT TO BE Ys" MAX. MENU BOARDS I II I w w � COORDINATE WITH THE McDONALD'S AREA CONSTRUCTION MANAGER I 7 i ii i -. -.. z W im CT CERAMIC WALL TILE: DALTILE, ELEVARE I I A3.0 II I �- `x z o o Q II I — PICK—UP SHELF fi w °w COLOR: LUNAR EL 40 SIZE: 4"x`16" PATTERN: 1/3 MAX. I I II I E OFFSET RUNNING BOND I C I o GROUT: MAPEI 47 CHARCOAL — JOINT TO BE Ys" MAX. I ( D I ii i ! Q COORDINATE WITH THE McDONALD'S AREA CONSTRUCTION MANAGER I I I o w I II I m o I II I I— �rnrn I II I m n N _ — ___ — II I w =c c �_ ==_- - — � o ~ mem zoa C U :1 - - - - - - - W ?, c w Qco 0 a- 5 INTERIOR ELEVATION—FINISHES op ° U a m N �> o . ap I o n o � 3NEo� Vn I I a a EQ. EQ. Lo o o co.� a) co a) ° ° °' 'o `° E to 'c(f j 8, a E ooi0 0 0 c p o c �S N p O 0 0 0 C O L L ( C O V) U U d p 1/2" TEMPERED GLASS W/ ETCHED MCCAFE LOGO ON FRONT SIDE OF o o °'o 0 a) o GLASS. MITER CORNER, CENTER IN LOW WALL. c 0 I J _ O p !I ,Y 0 0 U SOLID SURFACE WALL CAP I 1.� U c o p c o 0 ap_ c a� I U L i V) ° U p N N U N 1/4" SHIM SPACE FOR GLASS, ; 1 FRONT COUNTER PLAN aN TE co :3BLOCKING TO SUPPORT SOLID L) ° o a o SURFACE TOP Al 0 1 /2" = 1 —0 ��_o 0- U C O m o CBB RETURN WALL & GLASS °` o° ° N C N N p N 7 N O a O 0 7 (n N.0 U W L �= 0 O U � N Ir d PICK—UP SHELF BY G.C. SOLID SURFACE ON DINING w cD co 1 —2 1 —6 SEE DECOR DRAWINGS ROOM SIDE OF WALL ;� m o o m Q o C Lo CONDIMENT CENTER (REFERENCE) ( ) 3 0 o w REFERENCE TOP DEPTH FOR CORIAN MATERIAL Lo I' Z ? N o N \ Of oN INTERIOR SELECTION < Y N _w LLJ � �_ w 8" DIGITAL MENU BOARDS TO BE RIGHT I I o o Q o cfl HOLD DIMENSION (HOLD) (ABOVE CENTER OF ORB/ PICKUP EDGE JUSTIFIED FOR PLACEMENT 1/2 FURNITURE GRADE I I N O C3 HERE SIGN ALIGNED WITH ORDER HERE SIGN CENTERED PLYWOOD SUBSTRATE I I ; N FOR UNDERMOUNTED COUNTER) CENTER OF PICK-UP SHELF ON ORDERING AREA j EQUIPMENT FRP FINISH ON KITCHEN Z . MENU MENU MENU SIDE OF WALL II I z O I 1" ADX PLYWOOD C° Q Z 2x4 METAL FRAMING TYP. SUBSTRATE-VERIFY SOLID CORIAN I— — OP OF ORDER HER SIGN 4 D MECHANICAL ANCHOR TO SURFACE AT ALL Z w ALIGNED WITH TOP OF co N W/COUNTER TOP O = PICK-UP HER SIGN z `'' SUBFLOOR I MANUF. CUSTOMER-EXPOSED 0 QUAL QUAL Q � � SIDES. COLOR: "LINEN" > NOTE: COUNTER OR "RICE PAPER" LL: z I I N COORDINATE WITH THE � Q [ K301 w N � FLOOR FINISH I I i > SUPPORT WALL 9 „ _o O DECOR DRAWINGS 2 I I- PICK-UP 0I w g Lo FURNISHED AND = 71' � _ SHELF m I I z N BY I FRP FINISH ON (OFFSET � w lo- INSTALLED o O X I I ! 0 z } G.C. N o KITCHEN SIDE FROM = M t o I d I I z � w Z a FACE OF o Q N I N m I I O J 0 (3) 2X6 TREATED COUNTER) � a � U) � m w c SILL PLATE - I = PRESENT ORDERING I I s _ w w ANCHOR TO FLOOR 0 3'-q" 3'-7j" o w 0 'o W/ 3" SHOT PINS mi 6" TILE = 3'-0" MIN. s'-��" I I L- m w ~ Q 48" O.C. z o u BASE ADA HOLD PER PLANO00 U` w w N a° Wz :!� Z LLI QUARRY TILE FLOOR SEE DECOR FOR FLOOR TILE5„ O X � o w M CV W o cn o 7 PICK-UP SHELF SECTION (P— INTERIOR ELEVATION 3 CBB WALL SECTION 031. 745.00.0 A3.0 1 "= 1 '-0" /4°' - V-0" A3.0 1 1 /2"= 1 ' -0" 2 NOT USED Z A3.0 Ll A w N DETAILS & NOTES MECHANICAL_ NOTES ABBREVIATIONS m GENERAL: 1 . ALL WORK PERFORMED SHALL BE IN ACCORDANCE WITH ALL LOCAL CODES 20. ALL ROOFTOP CONDENSING UNITS THAT DISCHARGE HORIZONTALLY SHALL BE CONDENSATE PIPING: ACM AREA CONSTRUCTION MANAGER AND ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. ORIENTED SUCH THAT THE DISCHARGE DOES NOT BLOW IN THE DIRECTION OF 1. CONDENSATE PIPING SHALL BE GALVANIZED STEEL, COPPER OR PVC. AN OUTDOOR AIR INTAKE.MK 2. ALL DIMENSIONS, CLEARANCES AND TOLERANCES SHALL BE VERIFIED PRIO. 2. PVC PIPE SHALL BE PAINTED WITH WATER BASED LATEX PAINTING TO RESIST BSI BEVERAGE SYSTEM INSTALLER TO INSTALLATION. COMMERCIAL KITCHEN EXHAUST SYSTEMS: DEGRADATION FROM ULTRAVIOLET' EXPOSURE. 1 . ALL METAL DUCTWORK USED FOR THE CONVEYANCE OF GREASE-LADEN AIR 3. ALL MATERIALS, FIXTURES AND EQUIPMENT USED SHALL BE IN ACCORDANCE SHALL BE CONSTRUCTED OF MINIMUM 18 GAUGE STAINLESS STEEL OR 16 3. PIPE SUPPORTS SHALL BE RPS MODEL PMP-2 OR EQUAL. QUANTITY AS EC ELECTRICAL CONTRACTOR WITH McDONALD'S SPECIFICATIONS. SPECIFICATIONS ARE CONTAINED WITHIN GAUGE CARBON STEEL (BLACK IRON). REQUIRED DEPENDANT UPON PIPING MATERIAL. THESE DRAWINGS AND THE McDONALD'S PROJECT MANUAL. ANY CONTRACTOR IN NEED OF A COPY OF THE McDONALD'S PROJECT MANUAL SHALL CONTACT 2. ALL GREASE EXHAUST DUCTWORK JOINTS SHALL BE EITHER TELESCOPING OR 4. PIPING SHALL BE SUPPORTED AS FOLLOWS: FAC FIRE ALARM CONTRACTOR THE McDONALD'S AREA CONSTRUCTION MANAGER. ANY VARIANCE FROM THE BELL TYPE. BUTT-WELDED JOINTS ARE PROHIBITED. MATERIAL MAX. HORIZ. SPACING MAX. VERT. SPACING z McDONALD'S SPECIFICATIONS SHALL BE REVIEWED AND APPROVED BY THE COPPER PIPE 12 FT. 10 FT. O 3. ALL GREASE EXHAUST DUCTWORK SEAMS AND JOINTS SHALL BE ENGINEER-OF-RECORD. CONTINUOUSLY WELDED WATER-TIGHT ON THE EXTERNAL SURFACE OF THE GALVANIZED STEEL 12 FT. 15 FT. FPC FIRE PROTECTION CONTRACTOR DUCT SYSTEM. ALL WELDING SHALL BE PERFORMED BY A CERTIFIED WELDER. PVC 4 FT. 15 FT. u v 4. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH ITS LISTING AND/OR THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 4. ALL GREASE EXHAUST DUCTWORK SHALL BE EXTERNALLY INSULATED WITH A 5. CONDENSATE PIPING SHALL SLOPE A MINIMUM OF Y8" PER FOOT. GC GENERAL CONTRACTOR o ASTM E2336 LISTED AND LABELED GREASE DUCT ENCLOSURE SYSTEM. 5. SEE COORDINATION SCHEDULE FOR ADDITIONAL SCOPE OF WORK. INSULATION SHALL BE INSTALLED IN ACCORDANCE WITH ITS LISTING AND THE 6. CONDENSATE PIPING SHALL BE SIZED BASED ON THE FOLLOWING: 6. PRIOR TO BUILDING TURNOVER, A COMPLETE START-UP, TEST, ADJUST AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. TOTAL TONS SERVED MINIMUM PIPE 1.D. INSIDE DIMENSION BALANCE SHALL BE PERFORMED ON ALL MECHANICAL SYSTEMS. THIS WORK BY PIPE SIZE 5. ACCESS PANELS SHALL BE PROVIDED AT ALL CHANGES IN DIRECTION OF THE SHALL BE PERFORMED BY A CERTIFIED TEST AND BALANCE CONTRACTOR. A <20 TONS 3/4" CERTIFIED TEST AND BALANCE CONTRACTOR CAN BE FOUND BY VISITING: GREASE EXHAUST DUCTWORK SYSTEM. ACCESS PANELS SHALL BE INSTALLED KEI KITCHEN EQUIPMENT INSTALLER HTTP://WWW.AABCHQ.COM/DIRECTORY IN ACCORDANCE WITH THE INSULATION MANUFACTURER'S INSTALLATION >20 TONS, <40 TONS 1" INSTRUCTIONS AND SHALL BE LABELED AS FOLLOWS: "ACCESS PANEL - DO >40 TONS, <125 TONS 1Y2" HTTP://WWW.NEBB.ORG/DIRECTORY.HTM NOT OBSTRUCT". KES KITCHEN EQUIPMENT SUPPLIER HTTP://WWW.TABBCERTIFIED.ORG/SITE/CONTENT/CONTRACTORS/SEARCH 7. UPON COMPLETION OF THE PUNCHLIST, THE MECHANICAL CONTRACTOR AND 6. ALL HORIZONTAL GREASE EXHAUST DUCTWORK SHALL BE INSTALLED WITH A TEST AND BALANCE CONTRACTOR SHALL SUBMIT REDLINED OR AS-BUILT MINIMUM Y4" PER FOOT SLOPE AND SHALL BE PITCHED BACK TOWARD THE MC MECHANICAL CONTRACTOR DRAWINGS ALONG WITH THE TEST AND BALANCE REPORT AND ALL EQUIPMENT HOOD. Li OPERATION AND MAINTENANCE MANUALS TO THE McDONALD'S AREA 7. UPBLAST KITCHEN EXHAUST FANS SHALL BE LOCATED A MINIMUM OF 6 FT. 0/0 OWNER/OPERATOR o CONSTRUCTION MANAGER. A MINIMUM OF TWO (2) COPIES SHALL BE FROM ANY PARAPET WALL OR ADJACENT STRUCTURE AND SHALL TERMINATE A PROVIDED, ONE (1) FOR REGIONAL RECORDS AND ONE (1) FOR THE MINIMUM OF 40 INCHES ABOVE THE FINISHED ROOFING MATERIAL. RESTAURANT. w REFRIGERANT PIPING: PC PLUMBING CONTRACTOR 8. ALL PENETRATIONS OF FIRE-RATED WALLS SHALL BE FIRESTOPPED WITH AN 1 . ALL REFRIGERATION WORK SHALL BE PERFORMED BY A CERTIFIED APPROVED AND LISTED FIRESTOPPING SYSTEM. REFRIGERATION CONTRACTOR. F QF NEIl, RC REFRIGERATION CONTRACTOR VENTILATION SYSTEMS: 2. ALL REFRIGERANT PIPING SHALL BE SEAMLESS COPPER TUBING OF TYPE L IN 1 . ALL SHEET METAL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH ASTM B 88 AND ALL JOINTS SHALL BE SOLDERED. n, ACCORDANCE WITH LOCAL CODES AND SMACNA STANDARDS. y= 3. ALL REFRIGERANT SUCTION LINES SHALL BE INSULATED WITH A MINIMUM V 2. ALL DUCTWORK DIMENSIONS ARE INTERNAL FREE AREA DIMENSIONS AND SIZED 1-1/2" FOAM PIPE INSULATION. PIPE INSULATION INSTALLED OUTDOORS Ano 92e'� FOR 0.1 " W.C. PER 100 FT. OF DUCT. SHALL BE PROTECTED WITH AN APPROVED WEATHERPROOFING MATERIAL. 3. ALL SHEET METAL DUCTWORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH 4. ALL SUSPENDED REFRIGERANT PIPING SHALL BE SUPPORTED AS FOLLOWS: SMACNA TABLES FOR 2" W.C. AND SHALL BE SUPPORTED WITH AN APPROVEDMATERIAL MAXCOPPER TUBING <1Y4" . HORIZ. SPACING MAX. VERT.6 FT. 10 FT.SPACING f- LL 0 Q LL L.L HANGER AT INTERVALS NOT EXCEEDING 10 FT. - r` f V Wao COPPER TUBING >% 10 FT. 10 FT. ` ` ul 4. ALL DUCT DROPS INTO THE BUILDING SHALL BE INSTALLED WITH FLEXIBLE C� u,� o CONNECTIONS TO ISOLATE THE DUCTWORK SYSTEM FROM NOISE AND '.m.. °,., z =ua VIBRATION. FLEXIBLE CONNECTIONS SHALL BE TESTED IN ACCORDANCE WITH 5. ALL PIPE INSULATION SHALL BE PROTECTED FROM DAMAGE FROM PIPE W UL 181 AND LISTED AS CLASS 0 OR CLASS 1 . HANGERS. PROTECTION SHALL BE LIGHT GAUGE GALVANIZED STEEL OR EQUAL. ' .., z_ W o 5. ALL DUCT DROPS INTO THE BUILDING SHALL BE OFFSET AS NECESSARY TO ' a Z Z 01< ALLOW FOR THE CLEAR INSTALLATION OF THE EXTERNAL DUCTWORK 6. ALL REFRIGERANT PIPING SYSTEMS SHALL BE PRESSURE TESTED FOR LEAKS ` w U W INSULATION. PRIOR TO START-UP. ALL LEAKS SHALL BE REMEDIED PRIOR TO BUILDING - - - - - - - - - - - - TURNOVER. it - - - - - - - - - ° Q 6. ALL DUCTWORK BRANCHES SHALL BE SUPPLIED WITH A VOLUME DAMPER FOR w BALANCING. VOLUME DAMPER SHALL HAVE A 2" OFFSET TO ACCOMMODATE CO2 DETECTION EQUIPMENT: I \ ? o EXTERNAL INSULATION. 1. THE CO2 DETECTOR SHALL BE HARD-WIRED TO PREVENT TAMPERING AND - m �, U N SHALL BE INSTALLED AT 12" A.F.F. WITHIN A 5 FT. RADIUS OF THE CO2 7. TAKE-OFFS FROM RECTANGULAR TO ROUND DUCT SHALL BE DUCTMATE STORAGE TANKS. ; = m Z o STRAIGHT-SIDED OR CENTER HIGH-EFFICIENCY TAKE-OFFS WITH A 2" DAMPER I �I c;:Y a STAND-OFF TO ACCOMMODATE FOR EXTERNAL INSULATION. 2. ONE (1) AUDIBLE AND ONE (1) VISUAL ALARM SHALL BE INSTALLED A I '' Q co 3:d MINIMUM OF 7 FT. A.F.F., IN PLAIN SIGHT IN THE SAME ROOM AS THE CO2 8. ALL DUCTWORK JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS SHALL BE STORAGE TANKS. - it SEALED WITH WELDS, GASKETS, MASTICS (ADHESIVES), TAPES, ETC. ALL 0 ° SEALANT MATERIALS SHALL BE LISTED IN ACCORDANCE WITH UL 181A OR 3. ONE (1) AUDIBLE AND ONE (1) VISUAL ALARM SHALL BE INSTALLED A H U N C•N 181 B. MINIMUM OF 7 FT. A.F.F., AT THE BACK OF THE KITCHEN AND IN PLAIN --- - __.... U L C C ° L SIGHT FROM THE MAIN SIDE OF THE PREP LINE. I I r a E � ° N 9. ALL SUPPLY AND RETURN SHEET METAL DUCTWORK LOCATED WITHIN THE o oO`, N o a-DEo ° CEILING SPACE SHALL BE EXTERNALLY INSULATED. INSULATION SHALL BE 2" NATURAL GAS SYSTEMS (IF APPLICABLE): ° a ° U U U C THICK MICROLITE XG-100 BY JOHNS MANVILLE OR EQUAL. 1. ALL GAS PIPING, WATER HEATER VENTS, INTAKES AND FLUES SHALL CONFORM G' o �° TO THE CURRENT VERSION OF NEPA 54, NATIONAL FUEL GAS CODE, AND ANY __ I _ __-_ _ __ 10. ALL SUPPLY AND RETURN SHEET METAL DUCTWORK LOCATED OUTSIDE OF THE LOCAL CODE REQUIREMENTS. o BUILDING SHALL BE INTERNALLY LINED WITH A 1" THICK FIBERGLASS (MIN. I =:';\ `° ♦� ? R-4.2) AND EXTERNALLY INSULATED WITH A %" THICK RIGID POLYSTYRENE, 2. THE NATURAL GAS MAIN PIPE SIZING IS BASED ON THE FOLLOWING: /� �`_,,i ® N o o r___-- U POLYURETHANE OR POLYISOCYANU RATE BOARD (MIN. R-7.5). INTERNAL A. MINIMUM SUPPLY PRESSURE AT THE METER OF 2 PSIG O C O C N O - ° t FIBERGLASS INSULATION SHALL BE LIINATEX BY JOHNS MANVILLE OR EQUAL. B. 1 PSIG PRESSURE DROP FROM METER TO FARTHEST APPLIANCE ° C. ° ° 0 ° EXTERNAL RIGID BOARD INSULATION SHALL BE THERMAPINK BY OWENS C. 1,000 BTU PER CU. FT. OF NATURAL GAS I o 0 ° ° CORNING OR EQUAL. o � o� � � ° 3. GAS PIPING RUN-OUTS TO EQUIPMENT ARE SIZED BASED ON THE FOLLOWING: C v s ° cn 11 . ALL EXPOSED SPIRAL DUCTWORK SHALL BE INTERNALLY INSULATED TO A. SUPPLY PRESSURE AT THE REGULATOR OF 10" W.C. (Y4 PSIG) / - (U ° J PREVENT CONDENSATION (MIN. R-4.3). INTERNAL INSULATION SHALL BE 1 " B. 0.5" W.C. PRESSURE DROP FROM REGULATOR TO FARTHEST APPLIANCE d Q)*-6 - THICK SPIRACOUSTIC PLUS BY JOHN'S MANVILLE OR EQUAL. C. 1,000 BTU PER CU. FT. OF NATURAL GAS u I U 7).° ° Q) N ° ° ° Q N C U U N 12. ALL DUCTWORK PENETRATIONS THROUGH FIRE-RATED WALLS, BARRIERS OR 4. ALL NATURAL GAS PIPE SHALL BE SCHEDULE 40 CARBON STEEL PIPE WITH ° ° xxv�� o ` PARTITIONS SHALL BE PROTECTED WITH A FIRE DAMPER. THE PERIMETER OF MALLEABLE IRON FITTINGS AND SHALL BE COMPLY TO ONE OF THE I p L a E � Q O N � Q v U THE FIRE DAMPER SHALL BE FIRESTOPPED WITH AN APPROVED AND LISTED FOLLOWING STANDARDS: ASME B36.10, 1OM; ASTM A 53; OR ASTM A 106. q N FIRESTOPPING MATERIAL. C o 3 C a w ° 5. NATURAL GAS PRESSURE REGULATORS SHALL BE MAXITROL 325 SERIES OR ° 13. ALL EXTERIOR SHEET METAL DUCTWORK SHALL BE EXTERNALLY WRAPPED WITH EQUAL. AN APPROVED WEATHERPROOFING MATERIAL TO PROTECT AGAINST WATER -- I I < ° 0 a ° 0 PENETRATION AND CORROSION. SIDES AND TOP OF EXTERNAL 6. ALL SUSPENDED STEEL PIPING SHALL BE SUPPORTED AS FOLLOWS: III � 0 - o 5 s s WEATHERPROOFING SHALL BE ALUMAGUARD 60 MIL UV BARRIER BYSIZE MAX. HORIZ. SPACING MAX. VERT. SPACING I III ~ 3 C (n :. POLYGUARD OR EQUAL. BOTTOM OF EXTERNAL WEATHERPROOFING SHALL BE Y2" 6 FT. 6 FT. / J VAPORGUARD 5 MIL MEMBRANE BY POLYGUARD OR EQUAL. 3 J co �- o _ /4" TO 1 " 8 FT. 8 FT. C III ; o o m J w 0 14. ALL FLEXIBLE DUCTWORK, METALLIC AND NONMETALLIC, SHALL CONFORM TO >1Y4 10 FT. 10 FT. _ _ III z W N o u --Do D Li THE FOLLOWING: _- _ III < ~ � v w A. 2" THICK INSULATION (R-6.0) 7. GAS PIPING SHALL NOT PENETRATE ANY FIRE-RATED CHASE OR SHAFT, i III 0 o Q bi u� o CD B. INTEGRAL VAPOR BARRIER DUCTWORK OR PLENUM. iLlu 00 III u C. LISTED AND LABELED UL 181 , CLASS 0 OR CLASS 1 D. INSTALLED IN ACCORDANCE WITH: 8. ALL NATURAL GAS PIPING INSTALLED OUTDOORS SHALL BE COATED WITH A N i. SMACNA STANDARDS, CORROSION RESISTANT PAINT. PAINT COLOR SHALL BE ORANGE OR YELLOW. ,�� L // _m ii. AIR DIFFUSION COUNCIL INSTALLATION GUIDELINES, AND/OR iii. MANUFACTURER'S INSTALLATION INSTRUCTIONS 9. ALL INTAKE AND VENT PIPING FOR SEALED-COMBUSTION WATER HEATERS SHALL BE PVC OR ABS, SHALL BE SIZED AND INSTALLED IN ACCORDANCE 14. FLEXIBLE DUCTWORK SHALL NOT PENETRATE WALLS. SHEET METAL DUCTWORK WITH THE MANUFACTURER'S INSTRUCTIONS AND SHALL BE INSTALLED BY THE I / v IS REQUIRED AT ALL FIRE-RATED AND DRAFTSTOP WALL PENETRATIONS. PLUMBING CONTRACTOR. - \ o I .o - - - I 15. ALL COVERINGS, LININGS AND ADHESIVES (TAPES, ETC.) SHALL HAVE A 10. ALL WATER HEATER VENTS SHALL BE LOCATED A MINIMUM OF 10 FT. - i 0 0 0 °I 0 0 -F \ FLAME-SPREAD INDEX NOT GREATER THAN 25 AND A SMOKE-DEVELOPED HORIZONTALLY FROM ANY OUTDOOR AIR INTAKE. WHERE A WATER HEATER 0 0 0 0 0 0 INDEX NOT GREATER THAN 50. VENT IS LOCATED WITHIN 10 FT. OF AN INTAKE, THE FLUE OR VENT SHALL ! - ,,, TERMINATE A MINIMUM OF 2 FT. ABOVE THE INTAKE. 16. DUCT-MOUNTED SMOKE DETECTORS SHALL BE INSTALLED IN SYSTEMS WITH o g N UPON COMPLETION OF INSTALLATION THE GAS PIPING SYSTEM SHALL BE. z DESIGN CAPACITY GREATER THAN 2,000 CFM. SEE MECHANICAL DRAWINGS 11 0 PURGED OF DELETERIOUS MATERIAL AND SHALL BE PRESSURE TESTED. � W z FOR LOCATIONS OF SMOKE DETECTORS. DUCT-MOUNTED SMOKE DETECTORS z PRESSURE TESTING SHALL BE PERFORMED WITH THE EQUIPMENT SHUT-OFF - o ARE NOT REQUIRED WHEN THE BUILDING IS PROTECTED THROUGHOUT BYVALVES IN THE CLOSED POSITION TO PROTECT EQUIPMENT FROM DAMAGE DUE J ~ � ° a AREA SMOKE DETECTORS CONNECTED TO A FIRE ALARM SYSTEM WHERE THE -I L_ w TO EXCESSIVE PRESSURE. FIRE ALARM SYSTEM IS DESIGNED TO SHUT DOWN THE ROOFTOP UNITS. o w c FD Fh _ � 7, 12. AFTER THE PRESSURE TEST HAS BEEN COMPLETED AND ANY LEAKS REPLACE EXISTING 2-PLATTEN GRILL m ~ a 17. ALL SUPPLY AIR DIFFUSERS SHALL BE INSULATED TO PREVENT CONDENSATION. o z Ln o REMEDIED, THE INSTALLING CONTRACTOR SHALL MEASURE AND VERIFY THE WITH A 3-PLATTEN GRILL (GAS INPUT: O O - 00 18. ALL AIR DEVICES LOCATED IN DRYWALL CEILINGS SHALL BE SUPPLIED WITH AN FOLLOWING GAS PRESSURES WHILE EQUIPMENT IS IN OPERATION: 75 MBH). FIELD VERIFY EXISTING INTEGRAL VOLUME DAMPER ACCESSIBLE FROM THE AIR DEVICE FACE TO A. GRILL - 6" W.C. NATURAL, 14" W.C. L.P. CONDITIONS. � H - o w W 't FACILITATE BALANCING. B. FRYER - 6" W.C. NATURAL, 14" W.C. L.P. (J� °- C. WATER HEATER - 6" W.C. NATURAL, 14" W.C. L.P. bi O X vo x w 19. ALL OUTDOOR AIR INTAKES SHALL BE LOCATED A MINIMUM OF 10 FT. D. HVAC UNIT - 6" W.C. NATURAL, 14" W.C. L.P. N W o W U)o HORIZONTALLY FROM ANY SOURCE OF CONTAMINATION SUCH AS EXHAUST 031 .1745.00.0 FANS, PLUMBING VENTS, WATER HEATER FLUES, ETC. WHERE A CONTAMINANT 13. IF THE MINIMUM PRESSURES ARE NOT MET, THIS SHALL BE IMMEDIATELY SOURCE IS LOCATED WITHIN 10 FT. SOF AN INTAKE, THE INTAKE OPENING REPORTED TO THE MCDONALD'S AREA CONSTRUCTION MANAGER. MECHANICAL PIPING PLAN z 1 00 SHALL BE LOCATED A MINIMUM OF 2'. FT. BELOW THE CONTAMINANT SOURCE. M1.0 SCALE. 1/4" - 1 '-0" w MECHANICAL PLAN NOTE: VERIFY SCOPE OF WORK WITH PROJECT MANAGER BEFORE / BEGINNING DEMOLITION IXI � KEYED NOTES: KEYED NOTES: 1 1 . 12"x12" ACCESS PANEL COORDINATE INSTALLATION WITH L I . ACCESS PANEL FOR THERMOSTATIC MIXING VALVE (SEE G.C.) CHEMICAL SYSTEM INSTALLATION DETAIL) 2. ECOLAB CHEMICAL SYSTEM (SEE CHEMICAL SYSTEM 2. THERMOSTATIC MIXING VALVE SET TO 110°F (SEE VALVE INSTALLATION DETAIL) SCHEDULE) G \ I 3. 24"Wx36"H WALL GUARD (QTY. 2) FURNISHED WITH MOP 3. PIPE THROUGH WALL WITH ESCUTCHEON PLATE4. SHUT-OFF VALVE i I SINK (SEE PLUMBING FIXTURE SCHEDULE) 5, 3/4" MHT CONNECTION z 4. MOP SINK FAUCET WITH INTEGRAL VACUUM BREAKER (SEE 0 PLUMBING FIXTURE SCHEDULE) ***PLUMBER'S WORK ENDS AT MHT CONNECTION*** i I 5. HOSE FURNISHED WITH MOP SINK FAUCET (SEE PLUMBING FIXTURE SCHEDULE) 6. HOSE TO CHEMICAL SYSTEM U of o� _� I 6. HOSE BRACKET FURNISHED WITH MOP FAUCET (SEE 7. ECOLAB SOLIDSENSE CHEMICAL DISPENSER o PLUMBING FIXTURE SCHEDULE) 8. ECOLAB SMARTSHAPE CHEMICAL DISPENSER i I 7. FLOOR GRATE 9. CHEMICAL DISPENSING HOSE 1 it II 1 `0 al I I 2 4 I / \ ��\' � I I 7 II 5 i 3 ® ® I- II I o 11 I 8 0 I I I I W � 9 II II I I I II I ��- °F^ ` �o d a Q ° d Q RELOCATE EXISTING MOP SINK ` ° ' ' < LL 90 AND ALL ASSOCIATED PIPING, a =LLo FIELD VERIFY EXISTING I DETAIL 4 DETAIL 5 1 DOMESTIC WATER, WASTE, & VENT PIPING DEMO PLAN CONDITIONS AND PROVIDE NEW 3 DOMESTIC WATER, WASTE & VENT ISO RECESSED MOP SINK P1.0 CHEMICAL SYSTEM INSTALLATION Pl.o ' . zLu wz PIPING IF REQUIRED. CAP =0Z P1.0 SCALE: 1/4" - 1 '-0" EXISTING PIPING NOT RE-USED P1.0 N.T.S. SCALE: Y2"=1 '-0" SCALE: Y2"=1 '-0" w AIR TIGHT. Lu <0� Qzo z �-w° Cowes �za DRAWING NOTES W °W 0 Z Qo 1. ALL EXISTING PIPING LOCATIONS AND SIZES SHALL BE FIELD VERIFIED PRIOR TO BEGINNING ,.. � WORK. a o woC,cp - - - 2. PIPING ROUTES ARE GENERAL AND MAY VARY DUE TO FIELD CONDITIONSC . COORDINATE ALL PIPE o W �0 �� � � � ROUTES WITH OTHER TRADES. = Q zo is \ � 020 cc- - 3. ALL WATER DISTRIBUTION PIPING SHALL BE INSULATED. INSULATION NOT SHOWN FOR CLARITY. a Q P1 I I ' ' :. — — — SEE PLUMBING NOTES FOR INSULATION REQUIREMENTS. RELOCATED - — — — — — —_--__ � a - 4. SEE DRAWING P4.0 FOR PLUMBING SCHEDULE, AND GENERAL NOTES. ° -0 MS -'- - - - - - - - - — — S`1v - - u o II II \ 0 4 0 L 7a N N O C CT II II 3 I!.' co ° o ° II II �i � iii; � � � o � � � � �o P2 P6 J L I o o 3 co .o ° _Lig__ ,� O o a 3 ° ° p O U C s C. p a O p 0 0 0 C O II II s N ° Q' � ° _ _ o OO ( r--- ---- -- -- ° c ° o o 0 L---� p o o E cu w r---� °° J c L J � O r-�� :O O I I c c O 7 U7 7 0 0 O y � L o n Co co P 3 I o ° + O U r - -----------� raw 3 •� c - 3 r--- -- -- �'- ° 3 O ° O ° -- r- -� U g,- �- "I,( o a _ a c l m J I/' �`\I LJ N J N O Y LQ N O J of O O O Q Ld ` i O O L J W N I III r-- � � o � L, i ° 00* \/ O\i m ooN oQ Do W WAS R i ° J - - - L---J KEYE � NTES � � � = w N � a0 L U - tw- D (n o cj - - - -- -- o li—SIC ` CONNECT NEW DOMESTIC COLD AND/OR HOT WATER PIPING TO NEW AND RELOCATED FIXTURES � o c - -- -- _ _ cno)% � ;% I P1 AS SHOWN FROM EXISTING WATER LINES. FILED VERIFY EXACT LOCATIONS. WATER LINES INSIDE r,---, r o , BUILDING SHALL BE COPPER. r- r- -1 ° L---- ❑ PROVIDE NEW VENT LINE TO NEW AND/OR RELOCATED EQUIPMENT AS SHOWN. CONNECT VENT �� C III P2 LINE TO EXISTING VENT MAIN. FIELD VERIFY EXISTING CONDITIONS. z / \ - --- -- SHUT-OFF VALVE FOR WAREWASHER ISOLATION. SEE VALVE - - I SCHEDULE. ALL SHUT OFF VALVES SHALL BE LOCATED OVER P I I � R SUS ENDED CEILINGS FOR ACCESSIBILITY. DO NOT LOCATE IN AREAS I � lir I I pl 00 WITH DRYWALL CEILINGS. FP 4 PROVIDE WALL BOX (WB-2 FOR WAREWASHER. SEE PLUMBING SCHEDULE ON SHEET P4.0. - - -� ®_ > r J Pis / / INDIRECTLY DRAIN RELOCATED BLENDED ICE AND SPECIALTY COFFEE MACHINES TO NEW FLOOR z Q Ln N — P5 SINKS FS-1 WITH AIR GAP, CAP EXISTING NOT REUSED PIPING AIR TIGHT. ROUTE NEW 3" z r __ .... _.. ..._. _. .. .-... __... . < z - GREASE LINE O EXISTING GREASE LINE. FIELD VERIFY EXISTING CONDITIONS. z w - - — - ° - - - - F- cn _ _ _ _ -_- - _ r---, ___J Q � I o � w - ' - g r CONNECT NEW 3"GREASE LINE TO RELOCATED MOP SINK MS-1 RUN TO MAIN GREASE LINE. — o_ w o 0 FSI oa000 I - � a �_ ---, p j % P6 ( ) o r - 01 IF I -- y FIELD VERIFY EXISTING CONDITIONS. LL_ m LJ Q 00 — _- - - - 0 0 J N OJ - - - - - - - - - - - --- - - - W z Q w z U z o L Ln n a � I w O X " Li _ P2 P5 ~ N W w W ~ � o cn o 031 .1745.00.0 2 DOMESTIC WATER, WASTE, & VENT PIPING � .P 1 � O �,WATER,WASTE & VENT PIPING m z 0 m 0 cn w 0 I w E-- Lij IT d 0 0 7 c- e X� 00 II --- Z ----- ------ U ---- ?" z �wz F p ---- ---- W-- i r,..„ <a a - u,. w W 30 --- r z a&o 1 P {-W= LLJ 00 LLJ --- z ---A — n m 0 __ �.., W 7'-138>, ! I I i --- - --------- OO w F- m'00 II_ Ld 0 CU co 0 LJ II II o s o a -- -- o ° a a N C ° � ° � o o ° U) ( U ? Q 6 ---' `----' `----. a U N -0 U Q p IIColl �lB 0 3� . o U C N L U NtIDC o. v o C a 3 ° c 11,s O Np U O p 0 O a a s ® ® a s o ® ® ® ® ® ® ® s ® N ! = s - E , o ° E c c o_ }� p c U. O U O l�lMl� C) N � Ul C N s N C U OJ~ C O D O N --- 29'-9%/ " 2 68 UQ � � a � a _ U E 00 o cn O O 0Z °o ° ® ° ° ° n ° o d N C, O to Lo U LL, W L O O DJ N � LLJ Lo m o O m < � O w Ln Z w LijN N �p O ~ C/) U w -t w 0 o Q orcn CD o CD N O N N O� r Z U O NOTE: SEE SHEET P4.0 FOR PLUMBING FIXTURE SCHEDULE w Ln z a O N CD Z Z � w Z _ W -0 J ° O —J Q � W of C 1 UNDERGROUND WASTE ROUGH-IN LL_ o m � P1.6 SCALE: 1/14" = 1 '-0" Z w w in O o N cc W z Qw Z U Z o � w Lj -0 cnLiLd o a X O x O w w N LiJ v - o cn o 031 .1745.00.0 L'i w P1 � 6 V OVERHEAD/UNDERGROUND ROUGH-IN GENERAL PLUMBING NOTES N1OTES: . THIS SCHEDULE IS INTENDED AS A GUIDE FOR THE � WORK TO BE PERFORMED. ALL WORK SHALL BE m GENERAL: COORDINATED BETWEEN THE McDONALD'S AREA �� 0 CONSTRUCTION MANAGER AND ALL GC AND 0 1 . ALL WORK PERFORMED SHALL BE IN ACCORDANCE WITH ALL LOCAL CES 5. THE GREASE INTERCEPTOR SHALL BE VENTED IN ACCORDANCE WITH THE SUBCONTRACTORS. / AND ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. LOCAL CODE OR THE MANUFACTURER'S REQUIREMENTS. 2. ALL PLUMBING WORK SHALL BE PERFORMED BY A LICENSED PLUMBER. 6. ACCESS TO THE GREASE INTERCEPTOR SHALL BE PROVIDED WITH TWO (2) 2. ONE (1 ) COPY OF THE DECOR PACKAGE DRAWINGS 24-IN. MANHOLES. ALL SURFACE WATER MUST DRAIN AWAY FROM MANHOLES. SHALL BE SUPPLIED TO THE GENERAL CONTRACTOR 3. ALL DIMENSIONS, CLEARANCES AND TOLERANCES SHALL BE VERIFIED PRIOR AND EACH OF THE SUBCONTRACTORS. IT SHALL BE TO INSTALLATION. ALL ROUGH-IN LOCATIONS SHALL BE COORDINATED 'A'ITH 7, PIPING INLET AND OUTLET SIDES SHALL BE CLEARLY LABELED ON THE TOP THE RESPONSIBILITY OF THE GENERAL CONTRACTOR THE MANUFACTURER'S SUBMITTAL INFORMATION. OF THE GREASE INTERCEPTOR TO INSURE PROPER INSTALLATION. AND THE SUBCONTRACTORS TO INSURE THAT THEY HAVE RECEIVED THE DECOR PACKAGE DRAWINGS. 4. ALL DIMENSIONAL INFORMATION IS AS FOLLOWS (UNLESS NOTED OTHERWISE): DOMESTIC SUPPLY SYSTEMS: OR ANY WORK NOT CLARIFIED IN THIS SCHEDULE OR F A. UNDERGROUND PIPE IS TO FOUNDATION 1. THE INCOMING WATER SERVICE PIPE SHALL BE LOCATED A MINIMUM OF 5 FT. 3. F THE NOTES AND SPECIFICATIONS, PLEASE CONSULT B. OVERHEAD PIPE IS TO FINISHED WALL FROM THE EXITING SANITARY PIPE. WHERE A 5 FT. SEPARATION IS NOT o C. ELEVATIONS ARE TO FINISHED FLOOR POSSIBLE, THE BOTTOM OF THE WATER SERVICE PIPE SHALL BE A MINIMUM THE McDONALD'S AREA CONSTRUCTION MANAGER FOR f- OF 12 IN. ABOVE THE TOP OF THE HIGHEST POINT OF THE SANITARY PIPE. SCOPE OF WORK. m 5. ALL MATERIALS, FIXTURES AND EQUIPMENT USED SHALL BE IN ACCORDANCE u WITH McDONALD'S SPECIFICATIONS. SPECIFICATIONS ARE CONTAINED WITHIN 2. ALL UNDERGROUND SITE PLUMBING SHALL CONFORM TO NSF 61 , SHALL BE 4. ALL ROOFTOP UNIT EQUIPMENT SUPPLIED BY THE THESE DRAWINGS AND THE McDONALD'S PROJECT MANUAL. ANY CONTRACTOR TYPE K COPPER TUBING OR COPPER PIPE, POLYETHYLENE (PE) OR CPVC. MECHANICAL CONTRACTOR AND THE KITCHEN o IN NEED OF A COPY OF THE McDONALD'S PROJECT MANUAL SHALL CONTACT IF CPVC IS USED, FOAM INSULATION SHALL BE INSTALLED AT ALL CHANGES EQUIPMENT SUPPLIER SHALL BE ON SITE AT THE VALVE SCHEDULE OF DIRECTION TO ACCOUNT FOR EXPANSION AND CONTRACTION. SAME TIME FOR A SINGLE CRANE LIFT. EQUIPMENT THE McDONALD'S AREA CONSTRUCTION MANAGER. ANY VARIANCE FROM THE SITE ARRIVAL DATE SHALL BE COORDINATED BETWEEN McDONALD'S SPECIFICATIONS SHALL BE REVIEWED AND APPROVED BY THE 3. INCOMING WATER SERVICE PRESSURE SHOULD BE BETWEEN 45 AND 55 PSI THE AREA CONSTRUCTION MANAGER, MECHANIICAL TEMP. ENGINEER-OF-RECORD. STATIC. WHERE WATER PRESSURE SERVICE EXCEEDS 80 PSI STATIC, AN CONTRACTOR AND KITCHEN EQUIPMENT SUPPLIER. MANUFACTURER MODEL SETTING LISTING SERVES 6. SEE COORDINATION SCHEDULE FOR ADDITIONAL SCOPE OF WORK. APPROVED WATER-PRESSURE REDUCING VALVE WITH STRAINER CONFORMING WATTS LFMMV 11O'F ASSE 1017,1069,1070 CHEMICAL SYSTEM MIXING TO ASSE 1003 SHALL BE INSTALLED. WHERE INCOMING WATER PRESSURE IS 5. ALL ROOFTOP UNITS INSTALLED IN McDONALD'S B & G CB-1/2 - - RECIRC. SYSTEM BALANCING VALVE BELOW 45 PSI STATIC, A PRESSURE BOOSTER SYSTEM SHALL BE INSTALLED. RESTAURANTS SHALL BE HIGH EFFICIENCY EQUIPMENT. NIBCO 585-70-HC CHEMICAL SYSTEM SHUT-OFF- 7. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH ITS LISTING THE INSTALLATION OF STANDARD EFFICIENCY ROOFTOP AND/OR THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 4. IF THE RESTAURANT HAS A COMBINED WATER AND FIRE SPRINKLER SERVICE, UNITS IS PROHIBITED. 8. WHERE POOR SOIL CONDITIONS EXIST OR WHERE SUBSTANTIAL SETTLEMENT THE INCOMING WATER SERVICE SHALL BE SIZED BASED ON THE FIRE SPRINKLER CONTRACTOR'S HYDRAULIC CALCULATIONS6. ALL KITCHEN EQUIPMENT REQUIRING EXHAUST SHALL . OF EITHER THE PIPING, THE BUILDING OR ADJACENT WALKS, PLANTERS, ETC., BE INSTALLED IN ACCORDANCE WITH THESE PLANS. MAY OCCUR, THE CONTRACTOR SHALL PROVIDE ADEQUATE UNDERSLAB5. PROVIDE A MINIMUM Yz" ANNULAR CLEARANCE AROUND ALL PIPE SLAB ANY VARIATION FROM THESE PLANS SHALL BE Li STAINLESS STEEL PIPE HANGERS OR APPROVED OTHER SUPPORT. REPORTED TO THE AREA CONSTRUCTION MANAGER Q PENETRATIONS. AND THE ENGINEER-OF-RECORD. 9. ALL PIPE SLEEVES SHALL BE PROPERLY SEALED AND INSULATED TO PREVENT HEAT LOSS AND SEEPAGE. 6. A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER (RPZ) SHALL BE 7. WHERE GYPSUM BOARD CEILINGS ARE INSTALLED, THE BACKFLOW PREVENTER SCHEDULE INSTALLED AT THE INCOMING SERVICE WHERE REQUIRED BY CODE. MECHANICAL CONTRACTOR SHALL SUPPLY DRYWALL LLJ 10. ALL PIPE INSULATION SHALL BE PROTECTED FROM DAMAGE FROM PIPE MOUNTING FRAMES FOR LAY-IN TYPE DIFFUSERS AND HANGERS. PROTECTION SHALL BE (LIGHT GAUGE GALVANIZED STEEL OR 7. AN EXPANSION TANK SHALL BE INSTALLED ON THE COLD WATER LINE INLET FACE-ACCESSIBLE VOLUME DAMPERS TO FACILITATE ASSE EQUAL. TO THE WATER HEATER. SEE EXPANSION TANK SCHEDULE. �F CF K�y,Y AIR BALANCING. TYPE MFR. MODEL LISTING SERVES LOCATION 11 . ALL PENETRATIONS OF FIRE-RATED WALLS SHALL BE FIRESTOPPED WITH AN 8. ALL WATER SUPPLY PIPE WITHIN 5 FT. OF THE BUILDING AND INSIDE THE g NOT USED. APPROVED AND LISTED FIRESTOPPING SYSTEM. BUILDING SHALL COMPLY WITH NSF 61 AND SHALL BE TYPE L COPPER AG URN. WITH CHEM. SYS. 1055B CHEMICAL SYSTEM KITCHEN-MOP SINK �,x a TUBING, COPPER PIPE OR CPVC PIPE. AVB URN. WITH CHEM. SYS. 1001 CHEMICAL SYSTEM SUPP. RM.-3-COMP 9. NOT USED. SANITARY AND VENT SYSTEMS: AVB FURN. WITH FAUCET - MOP SINK FAUCET SEE DRAWINGS `ib 092-5 1 . THE BUILDING SANITARY PIPE SHALL BE LOCATED A MINIMUM OF 5 FT. FROM 9" CPVC PIPE SHALL BE FLOWGUARD GOLD OR FLOWGUARD BENDABLE AS A MANUFACTURED BY LUBRIZOL. 10. THE BEVERAGE SYSTEM INSTALLER FURNISHES, RUNS - Ro,�Ssip�� s THE INCOMING WATER SERVICE. WHERE A 5 FT. SEPARATION IS NOT AND CONNECTS ALL FLEXIBLE WATER AND SYRUP _ POSSIBLE, THE BOTTOM OF THE WATER SERVICE PIPE SHALL BE A MINIMUM LINES FOR ALL AFFECTED EQUIPMENT INCLUDING THE _ OF 12 IN. ABOVE THE TOP OF THE HIGHEST POINT OF THE SANITARY PIPE. 10. CPVC PIPE SHALL BE CONNECTED WITH FLOWGUARD GOLD YELLOW LOW-VOC FOLLOWING: SOLVENT CEMENT AS MANUFACTURED BY IPS WELD-ON OR OATEY. A. HOT CHOCOLATE DCV WATTS SD-3 1022 SODA TOWERS AND SPEC. COFFEE ,." • r. , o0 2. ALL SANITARY AND VENT PIPE SHALL BE PVC TYPE DWV, ABS OR CAST-IRON B. COFFEE BREWER - U WQ� WHERE REQUIRED BY CODE. 11 . ALL CPVC PIPE SHALL BE INSULATED TO PREVENT EXPOSURE TO GREASE. C. ICE MACHINE D. O.J. "~ 12. ALL SUSPENDED PIPE SHALL BE SUPPORTED AS FOLLOWS: U w�Z 3. ALL HORIZONTAL SANITARY PIPE SHALL BE INSTALLED WITH A MINIMUM PITCH E. SODA TOWERS 1 ;-, �0o AS FOLLOWS: MATERIAL MAX. HORIZ. SPACING MAX. VERT. SPACING PLUMBING FIXTURE SCHEDULE w w z PIPE SIZE MIN. SLOPE COPPER PIPE 12 FT. 10 FT. 11. ALL WATER HEATERS INSTALLED IN McDONALD) S z Fxo TAG DESCRIPTION MANUFACTURER MODEL WATER USE ACCESSORIES/COMMENTS F W 2Y2" OR LESS Y4" PER FT. COPPER TUBING <1Y4" 6 FT. 10 FT. RESTAURANTS SHALL BE HIGH EFFICIENCY c� wZD SEALED-COMBUSTION WATER HEATERS. THE FS-1 12x12 FLOOR SINK WITH HALF-GRATE ZURN ZN1901 PIPE SIZE: 3" GRATE: HALF - NICKEL-BRONZE z °Za 3" TO 6" Y8" PER FT. COPPER TUBING >1Y2" 10 FT. 10 FT. INSTALLATION OF STANDARD EFFICIENCY JAY R. SMITH 3435 DOME STRAINER: ALUMINUM SEE NOTE 8 W 8" OR LARGER Y16" PER FT. CPVC <1 " 3 FT. 0 FT. GRAVITY-VENTED WATER HEATERS IS PROHIBI1fED. UNDERCOUNTER ITEM: 152.06 SEE NOTE 7 {, z o CPVC >1Y4" 4 FT. 1___ll 0FT. - WAREWASHER ECOLAB 4. CLEANOUTS SHALL BE INSTALLED IN ALL HORIZONTAL DRAINAGE PIPE AND 12. THE AREA CONSTRUCTION MANAGER, PLUMBING U-LT-1 WALL BOX: WB-2 w SHALL BE LOCATED NOT MORE THAN 100 FT. APART. 13. A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER (RPZ) SHALL BE CONTRACTOR AND KITCHEN EQUIPMENT SUPPLIER SIOUX CHIEF 696-1011 Z) o INSTALLED AT THE INLET TO THE WATER FILTRATION SYSTEM. ALL PIPING MOUNTING HEIGHT: 12 m HAMMER ARRESTER INCLUDED WITH BOX SEE NOTE 7 m ��� 5. CLEANOUTS SHALL BE INSTALLED AT ALL CHANGES OF DIRECTION GREATER DOWNSTREAM OF THE RPZ SHALL BE COPPER OR CROSS-LINKED SHALL COORDINATE WHICH 3-COMPARTMENT SINK IS WB-2 WALL BOX FOR WAREWASHER " A.F.F. 21 U BEING INSTALLED IN THE RESTAURANT. NOTE: THE THAN 45 DEGREES. WHERE MORE THAN ONE CHANGE OF DIRECTION OCCURS POLYETHYLENE (PEX). INSTALLATION OF A POWERSOAK SINK REQUIRES A MOP SINK FIELD FABRICATED RECESSED - FLOOR FAUCET: F-2 ~ mZa IN A SINGLE PIPE RUN, ONLY ONE (1) CLEANOUT SHALL BE REQUIRED FOR LARGER WATER HEATER THAN THE STANDARD MS-1 (RELOCATED) INCLUDES HOSE, HOSE BRACKET AND TWO (2) 24"Wx36"H WALL GUARDS w U ° EVERY 40 FEET OF DEVELOPED LENGTH. 14. ALL DEVICES, APPLIANCES, AND APPARATUS INTENDED TO SERVE SOME 3-COMPARTMENT SINK. SEE DETAIL 2 ON P3.0 Q a SPECIAL FUNCTION SHALL BE PROVIDED WITH PROTECTION AGAINST BACKFLOW ZURN Z1400-SZ 6. CLEANOUTS SHALL BE INSTALLED ON PIPES PRIOR TO ANY SLAB AND CONTAMINATION OF THE WATER SUPPLY SYSTEM. ALL BACKFLOW 13. ALL GAS PIPING FOR COOKING EQUIPMENT SHALL FCO 6x6 FLOOR CLEAN OUT SEE DRAWINGS FOR PIPE SIZES PREVENTION DEVICES SHALL BE ASSE LISTED AND APPROVED FOR THE DEVICE JAY R. SMITH 4040 SEE NOTE 8 0 PENETRATION. ------- OR APPLIANCE THEY SERVE. TERMINATE IN THE CEILING PRIOR TO THE INSTALLATION OF THE PIPING CHASE. UPON U o ° U N 7. WHERE PIPING IS LOCATED WITHIN WALL CAVITIES, ACCESS TO THE CLEANOUTS INSTALLATION OF THE CHASE, THE GAS PIPING SHALL Q 0 ° o �° ` ° ° SHALL BE PROVIDED. 15. ALL WATER SUPPLY LINES SHALL BE PROVIDED WITH A QUARTER-TURN THEN BE CONTINUED IN THE CHASE FOR FINIAL v o a o 0 SHUT-OFF VALVE BEFORE FINAL CONNECTION TO EQUIPMENT. CONNECTION TO THE APPLIANCE. 8. CLEANOUTS ON 6-IN. AND SMALLER PIPES SHALL BE PROVIDED WITH A o ,j ° o 0 a° ° o ° U U N C CLEARANCE OF NOT LESS THAN 18 IN. CLEANOUTS ON 8-IN. AND LARGER 16. QUARTER-TURN SHUT-OFF VALVES SHALL BE INSTALLED UPSTREAM OF ANY 14. ALL GAS PIPING FOR ROOFTOP EQUIPMENT SMALL BEo ° ° PIPE SHALL BE PROVIDED WITH A CLEARANCE OF NOT LESS THAN 36 IN. INLINE BACKFLOW PREVENTION DEVICE. BROUGHT UP THROUGH PIPE PORTALS ON ROOF. 0 o N (nN N N 9. ALL SUSPENDED SANITARY AND VENT PIPE SHALL BE SUPPORTED AS 17. ALL VALVES AND BACKFLOW PREVENTION DEVICES SHALL BE INSTALLED WITH 15. FIRE SPRINKLER DRAWINGS SHALL BE DESIGNED AND C° E � o ° FOLLOWS: FITTINGS THAT FACILITATE REMOVAL IN CASE OF FAILURE. PERMITTED BY A FIRE PROTECTION CONTRACTOR OR o o o a 0 ° � 3 ° MAX. HORIZ. MAX. VERT. LICENSED FIRE PROTECTION ENGINEER. O U - ° C:: ° 18 .ALL OVERHEAD WATER LINES SHALL BE INSULATED WITH 1 " THICK EXTERNAL Q) o.° o c o 0 MATERIAL SPACING SPACING JACKETED INSULATION AND A MINIMUM INSTALLED R-VALUE OF 3.7. 16. ALL R-102 WET CHEMICAL FIRE SUPPRESSION `n 0 ° a ° ABS 4 FT. 10 FT. - -oo_� mE � c SYSTEMS FOR TYPE I HOODS SHALL BE DESIGNED o c U ° � o PVC (TYPE DWV) 4 FT. 10 FT. 19. PRIOR TO BUILDING TURNOVER, THE DOMESTIC WATER SUPPLY SYSTEM SHALL AND INSTALLED BY A LOCAL, ANSUL AGENT. THE USE NOTES: � o o ° CAST-IRON <10 FT. PIPE SECTIONS 5 FT. 15 FT. BE PURGED OF DELETERIOUS MATERIAL AND DISINFECTED. DISINFECTION 1 . SEE McDONALD'S PROJECT MANUAL FOR ADDITIONAL MANUFACTURERS U ( OF DRY CHEMICAL SYSTEMS IS PROHIBITED. THE 2. PLUMBING CONTRACTOR SHALL COORDINATE WITH G.C. TO PROVIDE BLOCKING FOR PROPER URINAL SUPPORT TO ORDER PLUMBING FIXTURES, ��R ° a, U SHALL BE DONE IN ACCORDANCE WITH THE LOCAL HEALTH CODE, PLUMBING U Q ° . a CAST-IRON (10 FT. PIPE SECTIONS) 10 FT. 15 FT. CODE OR IN ACCORDANCE WITH AWWA C651 OR AWWA C652. THE AKI TC EN EQUIPMENT SUPPLIER.IHANDLED THROUGH 3. PLUMBING CONTRACTOR SHALL COORDINATE WITH G.C. TO PROVIDE INTERIOR BLOCKING ON W/W BUILDING FOR WALL CLAMP CONTACT HD SUPPLY: . n o ° o 10. ALL PLUMBING FIXTURES SHALL BE VENTED AND THE MAXIMUM DISTANCE 4. YARD HYDRANT IS FOR TRASH CORRAL - SEE SITE PLAN FOR LOCATION PHONE: (866) 310-3576 a� ° U a FROM THE FIXTURE TRAP TO THE VENT SHALL BE AS FOLLOWS: STORM DRAINAGE SYSTEMS: 17. WHERE POSSIBLE, ALL ROOFTOP UNITS AND EXHAUST 5. PLUMBING CONTRACTOR SHALL ROUTE Y$" DRAIN PIPE FROM HOSE BIBB TO NEAREST FLOOR DRAIN OR FLOOR SINK E-MAIL: =o a ° 1 . ALL ROOF DRAINS SHALL BE SIZED IN ACCORDANCE WITH LOCAL CODES AND FANS ARE SUPPLIED WITH A FACTORY- 6. PLUMBING CONTRACTOR SHALL COORDINATE WITH G.C. TO PROVIDE BLOCKING FOR PROPER SINK SUPPORT MCDCOORD@HDSUPPLY.COM � 0 � Q U , - E TRAP SIZE SLOPE DISTANCE ° o ° ° o U 1Y4" Y4" PER FT. 2'_6°° SHALL CONFORM TO ASME Al 12.21 .2M OR A112.3.1 . DISCONNECT SWITCH. 7. SEE KITCHEN DRAWINGS FOR ADDITIONAL INFORMATION - PLUMBING CONTRACTOR SHALL COORDINATE INSTALLATION WITH K.E.S. (,� o ° a U 8. PLUMBING CONTRACTOR SHALL SPECIFY CONNECTION MATERIAL/TYPE WHEN ORDERING �� ° 1Y2" Y4" PER FT. 3'-6" 2. ALL STORM DRAINAGE PIPING SHALL BE ABS, PVC TYPE DWV OR CAST-IRON 18. ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECT 9. PLUMBING CONTRACTOR SHALL SPECIFY BURY DEPTH WHEN ORDERING 2" Y4" PER FT. 5'-0" WHERE REQUIRED BY CODE. SWITCHES FOR REMOTE CONDENSING UNITS. 10. PLUMBING CONTRACTOR SHALL PROVIDE GRID DRAIN, P-TRAP AND VALVE STOPS FOR ALL SINKS & LAVS u 3" Y8" PIER FT. 6'-0" w Co 3. ALL SUSPENDED STORM DRAINAGE PIPE SUPPORT REQUIREMENTS SHALL BE 19. ALL ELECTRICAL CONDUITS FOR ROOFTOP EQUIPMENT � o ° ° N U 4" & LARGER Y8" PIER FT. 10'-0" THE SAME AS THE SANITARY AND VENT REQUIREMENTS. SHALL BE BROUGHT UP THROUGH PIPE PORTALS ON a 4 a 3 ° 0 11 . ALL PLUMBING VENTS THROUGH THE ROOF SHALL TERMINATE A MINIMUM OF ROOF. COORDINATION SCHEDULE 12 INCHES ABOVE THE ROOF AND SHALL BE LOCATED A MINIMUM OF 8 FT. 4. ALL HORIZONTAL STORM DRAINAGE PIPE PITCH REQUIREMENTS SHALL BE THE Li In FROM ANY PARAPET WALL. WHERE A VENT TERMINATES WITHIN 8 FT. OF A SAME AS THE SANITARY AND VENT REQUIREMENTS. 20. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL FINAL NOTES: m o o m o w PARAPET WALL, THE VENT SHALL TERMINATE A MINIMUM OF 6 INCHES ABOVE INFORMATION. 1 . THIS SCHEDULE IS INTENDED AS A GUIDE FOR THE z ? N o Q \ � oN THE PARAPET. 5. ALL HORIZONTAL STORM DRAINAGE PIPE SHALL BE INSULATED WITH 1" THICK GENERAL REQUIREMENTS FURNISH INSTALL CONNECTION NOTES �- EXTERNAL JACKETED INSULATION AND A MINIMUM INSTALLED R-VALUE OF 3.7 21 . SEE STRUCTURAL DRAWINGS FOR ADDITIONAL MECHANICAL PERMIT MC WORK TO BE PERFORMED. ALL WORK SHALL BE � w TO PROTECT AGAINST CONDENSATION. INFORMATION. 1 -3 COORDINATED BETWEEN THE McDONALD'S AREA o Cr '� Q 0 cf v 12. ALL PLUMBING VENTS SHALL TERMINATE A MINIMUM OF 10 FT. HORIZONTALLY - Q � o FROM ANY OUTDOOR AIR INTAKE. WHERE A PLUMBING VENT IS LOCATED HOT WORK (WELDING) PERMIT (IF APPLICABLE) KES 1 -3 CONSTRUCTION MANAGER AND ALL GC AND 0/0 N O c WITHIN 10 FT. OF AN INTAKE, THE VENT SHALL TERMINATE A MINIMUM OF 2 6. CLEANOUTS SHALL BE INSTALLED IN ALL HORIZONTAL DRAINAGE PIPE AND 22. SEE MECHANICAL DRAWINGS FOR ADDITIONAL PLUMBING PERMIT _ PC 1 -3 SUBCONTRACTORS. FT. ABOVE THE INTAKE. SHALL BE LOCATED NOT MORE THAN 100 FT. APART. INFORMATION. ELECTRICAL PERMIT EC 1 -3 Ln FIRE SPRINKLER PERMIT (IF APPLICABLE) FPC 1 -3 2. ONE (1) COPY OF THE DECOR PACKAGE DRAWINGS 13. ALL SIDE WALL VENT TERMINATIONS SHALL BE PROTECTED TO PREVENT BIRDS 7. CLEANOUTS SHALL BE INSTALLED AT ALL CHANGES OF DIRECTION GREATER 23. SEE PLUMBING DRAWINGS FOR ADDITIONAL FIRE ALARM PERMIT (IF APPLICABLE) FAC 1 -3 SHALL BE SUPPLIED TO THE GENERAL CONTRACTOR >_ OR RODENTS FROM ENTERING OR BLOCKING THE VENT OPENING. THAN 45 DEGREES. WHERE MORE THAN ONE CHANGE OF DIRECTION OCCURS INFORMATION, AND EACH OF THE SUBCONTRACTORS. IT SHALL BE Z CONTRACTOR COORDINATION REQUIREMENTS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR IN A SINGLE PIPE RUN, ONLY ONE (1) CLEANOUT SHALL BE REQUIRED FOR _ 14. ALL FLOOR DRAINS THAT DO NOT SERVE EQUIPMENT SHALL BE PROTECTED EVERY 40 FEET OF DEVELOPED LENGTH. 24. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL PLUMBING SYSTEMS AND THE SUBCONTRACTORS TO INSURE THAT THEY AGAINST DRYING OUT EITHER THROUGH THE INSTALLATION OF A TRAP PRIMER, INFORMATION. WATER HEATERS PC PC PC 1 -4 HAVE RECEIVED THE DECOR PACKAGE DRAWINGS. o DEEP SEAL TRAP OR PROSET TRAP GUARD. 8. CLEANOUTS SHALL BE INSTALLED ON PIPES PRIOR TO ANY SLAB HOT AND COLD WATER PIPE PC PC PC 1 -4 3. FOR ANY WORK NOT CLARIFIED IN THIS SCHEDULE OR 15. ALL APPLIANCES SHALL DRAIN TO AN APPROVED SANITARY WASTE RECEPTOR PENETRATION. 25. SEE FIRE PROTECTION DRAWINGS FOR ADDITIONAL VENTS AND INTAKES PC PC PC 1 -4 IN THE NOTES AND SPECIFICATIONS, PLEASE CONSULT INFORMATION. (FLOOR SINK OR FLOOR DRAIN WITH FUNNEL). INDIRECT DRAINAGE FROM AN 9. WHERE PIPING IS LOCATED WITHIN WALL CAVITIES, ACCESS TO THE CLEANOUTS THERMOSTATIC MIXING VALVE _- PC PC PC 1 -4 THE McDONALD'S AREA CONSTRUCTION MANAGER FOR > APPLIANCE SHALL MAINTAIN AN AIR GAP BETWEEN THE PIPE OUTLET AND THE SHALL BE PROVIDED. 26. SEE FIRE ALARM DRAWINGS FOR ADDITIONAL POWER AND CONTROL WIRING _ _ EC EC EC 1 -5 SCOPE OF WORK. Q TOP OF THE RECEPTOR. THE MINIMUM DISTANCE BETWEEN THE PIPE OUTLET INFORMATION. o z AND THE TOP OF THE RECEPTOR SHALL BE TWICE THE DIAMETER OF THE 10. ROOF DRAINS AND OVERFLOW ROOF DRAINS SHALL BE PIPED INDEPENDENTLY. 4. SEE PLUMBING DRAWINGS FOR ADDITIONAL Q - Z APPLIANCE DRAIN PIPE. OVERFLOW ROOF DRAINS SHALL NOT BE CONNECTED TO THE PRIMARY ROOF 27. SEE KITCHEN DRAWINGS FOR ADDITIONAL INFORMATION. INFORMATION. z Li DRAINAGE SYSTEM. Q w GREASE INTERCEPTORS: 28. SEE DECOR DRAWINGS FOR ADDITIONAL INFORMATION. 5. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL _ Ll 1 . SEE SITE PLAN FOR THE SIZE AND LOCATION OF THE GREASE INTERCEPTOR. INFORMATION. o w o Lw I a L CQ 2. THE GREASE INTERCEPTOR SHALL BE INSTALLED IN A LOCATION THAT IS ~ z o Ln ACCESSIBLE FOR PUMPING. 0 CD -ico W z Q w z U z 3. THE GREASE INTERCEPTOR SHALL BE CONSTRUCTED OF FIBERGLASS ORI- � w PRECAST CONCRETE. GREASE INTERCEPTOR CONSTRUCTION SHALL CONFORM ch�a- > o TO ALL LOCAL CODES. N o X con C) nx w N N W w v w 4. PRECAST CONCRETE INTERCEPTORS SHALL BE CAPABLE OF 3,000 PSI 031 .1745.00.0 COMPRESSIVE STRENGTH AT 28 DAYS, SHALL BE REINFORCED WITH BAR OR WIRE MESH AND SHALL BE COATED WITH A MINIMUM OF TWO (2) LAYERS OF o21 NOVOLAC EPDXY ON THE INTERIOR. NOVOLAC EPDXY SHALL BEw p 1 00 ui SHERWIN-WILLIAMS NOVA-PLATE UHS (OR EQUAL). GENERAL NOTES ELECTRICAL SPECIFICATIONS AND GENERAL NOTES: 1. THE ELECTRICAL CONTRACTOR (E.C.) SHALL PROVIDE ALL LABOR AND MATERIALS NECESSARY 29. THE CONTRACTOR SHALL VERIFY THE CEILING CONSTRUCTION TYPE WITH ARCHITECTURAL 41. VERIFY CLEARANCES FOR ALL NEW OR EXISTING RELOCATED ELECTRICAL WORK BEFORE PROJECT DEMOLITION NOTES: LIGHTING: m FOR A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM/INSTALLATION. DETAILS BEFORE ORDERING LIGHTING FIXTURES IN ORDER TO CONFIRM PROPER MOUNTING. PROCEEDING WITH CONSTRUCTION. COORDINATE USAGE OF AVAILABLE SPACE WITH ALL THE FOLLOWING PROVIDES A GENERAL SCOPE OF WORK FOR THE ELECTRICAL L1. PROVIDE A WEATHERPROOF JUNCTION BOX IN PARAPET FOR FASCIA SIGN. FINAL TRADES. IN THE EVENT OF CONFLICTS, NOTIFY THE ARCHITECT AND ENGINEER BEFORE CONTRACTOR FOR THE DEMOLITION REQUIREMEATS OF THIS SITE. THIS SECTION CONNECTION BY OTHERS. VERIFY EXACT LOCATION OF SIGN WITH McDONALD'S PROJECT 2. MATERIALS AND INSTALLATION SHALL COMPLY WITH ALL CODES, LAWS, AND ORDINANCES OF 30. EACH SWITCH, LIGHT, RECEPTACLE, OR OTHER MISCELLANEOUS DEVICE SHALL BE PROVIDED PROCEEDING WITH THE WORK. IS NOT ALL INCLUSIVE, AND THE CONTRACTOR SHALL VISIT THE SITE AND MANAGER PRIOR TO INSTALLATION. FEDERAL, STATE, AND LOCAL GOVERNING BODIES HAVING JURISDICTION. WITH A GALVANIZED OR SHERARDIZED PRESSED STEEL OUTLET BOX OF THE KNOCKOUT TYPE, COMPARE EXISTING CONDITIONS TO THE REQUIREMENTS DENOTED ON THE OF NOT LESS THAN NUMBER 14 U.S. GAUGE STEEL. CONDUITS SHALL BE FASTENED WITH 42. WHERE EXISTING CONDUIT IS SHOWN ON THE DRAWINGS, IT IS SHOWN DIAGRAMMATICALLY. CONSTRUCTION DOCUMENTS TO DETERMINE THE EXACT EXTENT OF THE L2. COORDINATE THE LOCATION OF JUNCTION BOX (IN THE WALL) WITH THE OPENING IN TRELLIS (FOR THE LIGHT 3. ALL MATERIALS AND EQUIPMENT SHALL BE LISTED AND/OR LABELED BY U.L., ETL, CSA, OR LOCKNUTS AND BUSHINGS AND ALL UNUSED KNOCKOUTS SHALL BE LEFT SEALED. THERE THE EXACT ROUTING OF THE EXISTING CONDUIT SHALL BE DETERMINED ON THE JOB SITE BY DEMOLITION WORK REQUIRED. E.C. SHALL PROVIDE ALL DEMOLITION WORK FIXTURE WIRES). THE LOCATION OF THE JUNCTION BOX AND THE OPENING IN THE TRELLIS SHALL BE ALIGNED ANOTHER RECOGNIZED TESTING LABORATORY. SHALL BE SUFFICIENT ROOM FOR WIRES AND BUSHINGS AND DEEP BOXES SHALL BE THE CONTRACTOR. REQUIRED IN ORDER TO ALLOW FOR THE COMPLETE INSTALLATION AS DENOTED FOR THE LIGHT FIXTURE TO BE INSTALLED PROPERLY. COORDINATE INSTALLATION OF JUNCTION BOX AND ANY 4. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, GOVERNMENTAL FEES, TAXES INSTALLED WHERE REQUIRED. BOXES SHALL BE SECURELY AND ADEQUATELY SUPPORTED. WITHIN THESE DRAWINGS. NECESSARY OPENINGS IN TRELLIS WITH GC AND AREA CONSTRUCTION MANAGER. SEE LIGHT FIXTURE INSTALLATION INSTRUCTIONS FOR REQUIREMENTS REGARDING MOUNTING BRACKETS FOR USE IN C-CHANNEL AND LICENSES NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF ALL 31. NOT USED 43. NOT USED. TRELLISES. COORDINATE LOCATION WITH TRELLIS MANUFACTURER. ELECTRICAL WORK. 44. ALL HANGER AND/OR ROD SUPPORT SYSTEMS SHALL BE SUPPORTED TO THE BOTTOM RIB OF THE METAL DECK, WHERE APPLICABLE. INDOOR BUILDING LIGHTING POWER L3. EC SHALL FIELD VERIFY THAT LIGHT FIXTURES DO NOT OBSTRUCT OR CONFLICT WITH THE 5. THE CONTRACTOR SHALL PREPARE AND SUBMIT TO GOVERNMENTAL AGENCIES, UTILITY 32. IN SUSPENDED CEILINGS, SUPPORT CONDUITS AND JUNCTION BOXES DIRECTLY FROM THE l WORK OF OTHER TRADES. IF A DISCREPANCY IS FOUND, THE EC SHALL IMMEDIATELY COMPANIES, AND LOCAL CODE OFFICIALS, SHOP DRAWINGS AND/OR INSTALLATION DETAILS STRUCTURAL SYSTEM, DECK OR FRAMING PROVIDED FOR THAT PURPOSE. LIGHTING BRANCH D6. THE ELECTRICAL CONTRACTOR SHALL RELOCATE EXISTING POWER, DATA, NOTIFY THE GC BEFORE THE THE INSTALLATION OF SUCH FIXTURE(S). EC SHALL 0 WHICH ARE REQUIRED BY THESE AGENCIES FOR THEIR APPROVAL. CIRCUIT CONDUITS SHALL NOT BE CLIPPED TO THE CEILING SUPPORT WIRES OR SPLINE 45. PROVIDE A WRITTEN GUARANTEE THAT THE ELECTRICAL INSTALLATION IS FREE FROM AND TELEPHONE DEVICES IN THE BATHROOM AREAS TO BE AFFECTED. COORDINATE LOCATIONS OF ALL LIGHT FIXTURES IN DINING AREA WITH FINAL SEATING UNLESS THE CEILING SYSTEM HAS BEEN SPECIFICALLY DESIGNED FOR THAT PURPOSE AND MECHANICAL AND ELECTRICAL DEFECTS. CONTRACTOR AT THEIR COST SHALL REPLACE AND/OR REFER TO DEMO PLAN D1.0 FOR AFFECTED AREA. AND DECOR PLANS. APPROVAL HAS BEEN GRANTED BY THE ARCHITECT AND THE ENGINEER. APPRO REPAIR, TO THE SATISFACTION OF THE OWNER AND/OR THE MANUFACTURER'S INSTALLATION D7. THE ELECTRICAL CONTRACTOR SHALL RELOCATE EXISTING POWER, DATA, L4. IF PC-POS CASH REGISTER SYSTEM IS INSTALLED, EC SHALL RELOCATE FIXTURES ABOVE can 6. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT, ENGINEER, AND PROJECT MANAGER IN 33. E.C. SHALL PROVIDE "3M" FIRESEAL SYSTEMS FOR ALL CORES AND RACEWAY PENETRATIONS INSTRUCTIONS, ANY PARTS OF THE INSTALLATION WHICH MAY FAIL WITHIN A PERIOD OF 12 WRITING OF ANY MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN MONTHS FROM CONSTRUCTION ACCEPTANCE IN ACCORDANCE WITH THE CONTRACT AND TELEPHONE DEVICES FOR THE WALL RELOCATION. REFER TO DEMO FRONT COUNTER IX AVOID GLARE ON THE CASH REGISTER SCREENS. EC SHALL INSTALL o IN FIRE RATED WALLS AND PARTITIONS. FIRE RATE WALL AND CEILING PENETRATIONS, ETC. PLAN D-100 FOR AFFECTED AREA. CABLE WHIP TO FIXTURES SO THAT FIXTURE MAY BE RELOCATED FOUR FEET WITHOUT VIOLATION OF LAWS, ORDINANCES, RULES, OR REGULATIONS OF THE AUTHORITIES HAVING USING "CP-25" CAULK, "303" PUTTY AND/OR "FLAMESEAL" PUTTY AS PER MANUFACTURER'S DOCUMENTS, PROVIDED THAT SUCH FAILURE IS DUE TO DEFECTS IN MATERIAL, WORKMANSHIP, DISCONNECTING CABLE WHIP. JURISDICTION. INSTRUCTIONS TO MAINTAIN EXISTING AND NEW FIRE RATINGS. VERIFY FIRE RATING CONDITIONS OR FAILURE TO FOLLOW THE SPECIFICATIONS, MANUFACTURER'S INSTALLATION INSTRUCTIONS D8. THE ELECTRICAL CONTRACTOR SHALL DISCONNECT AND REMOVE ALL AND LOCATIONS PRIOR TO FINAL BIDS. ALL OPEN SLEEVE PENETRATIONS SHALL BE AND/OR DRAWINGS. EXISTING LIGHT FIXTURES IN THE AREAS ASSOCIATED WITH THE REMODEL L5. EC SHALL COORDINATE LOCATION OF ALL EXTERIOR LIGHTS WITH McDONALD'S PROJECT MANAGER TO AVOID 7. THE CONTRACTOR SHALL PREPARE AND SUBMIT TO THE FIRE PREVENTION BUREAU ALL FIRESEALED INSIDE AND OUTSIDE BY E.C. AFTER ALL CABLING IS COMPLETELY INSTALLED. TO ALLOW FOR THE NEW LIGHTING FIXTURE INSTALLATION AS DENOTED ON INTERFERENCE WITH ANY CORBELS, TRUSSES, BEAMS OR OTHER SPECIAL EXTERIOR TREATMENTS. INSTALL LIGHT DOCUMENTS, INCLUDING DRAWINGS AND SUBMITTALS, REQUIRED TO OBTAIN APPROVAL OF THE SEALING METHODS SHALL BE PROVIDED BY E.C. AND SHALL BE SUBJECT TO THE APPROVAL 46. CONTRACTOR SHALL PROVIDE ALL NECESSARY PROPERLY SIZED WALL OR MILLWORK MOUNTED THE PLANS AND DECOR DRAWINGS. COORDINATE ALL WORK WITH OTHER FIXTURES WITH CORRECT ORIENTATION PER MANUFACTURER'S INSTRUCTIONS EMERGENCY LIGHTING, LIFE SAFETY, AND EXIT SIGN SYSTEM(S) FOR TYPES AND OF THE CABLING CONTRACTOR. BOXES, RINGS, SUPPORTS, AND DEVICES AS REQUIRED VIA COORDINATION WITH TRADES AND WITH THE PROJECT MANAGER. LOCATIONS. A COPY OF THE APPROVED DRAWINGS SHALL BE PROVIDED TO THE ARCHITECT ARCHITECTURAL WALL SECTIONS, AND MILLWORK DETAILS. L6. THE USE OF "MC" CABLE IN LENGTHS OF 6 FEET OR LESS (WHERE PERMITTED BY LOCAL AND ENGINEER PRIOR TO THE START OF CONSTRUCTION. 34. NOT USED. 47. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THESE DRAWINGS. WHERE MORE GENERAL CODES) SHALL BE ALLOWED FOR WIRING TO INTERIOR LIGHTING FIXTURES. "ROMEX" OR STRINGENT REQUIREMENTS THAN THOSE DESCRIBED HEREIN OR AS SET FORTH UNDER CODES, pg. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE SALVAGE "BX" SHALL NOT BE USED. LAWS, AND ORDINANCES OF FEDERAL, STATE, AND LOCAL GOVERNING BODIES HAVING 8. ALL NEW ELECTRICAL WORK OR MODIFICATIONS TO EXISTING ELECTRICAL DISTRIBUTION PANELS, 35. NOT USED. REQUIREMENTS FOR ALL EQUIPMENT REMOVED AS PART OF THE JURISDICTION, THOSE GREATER REQUIREMENTS SHALL BE ADHERED TO. L7. EC SHALL VERIFY THAT NOT MORE THAN 3% VOLTAGE DROP EXISTS FROM THE LIGHTING PANELBOARDS, METERS, ETC. SHALL BE INSTALLED AS INDICATED ON THE ELECTRICAL DEMOLITION WORK WITH THE CONSTRUCTION PROJECT MANAGER. ALL 48. ALL NEW EMERGENCY LIGHTING FIXTURES AND EXIT SIGNS SHALL BE PROVIDED WITH AN PANEL TO ANY EXTERIOR LIGHTING FIXTURE OR SIGNAGE BALLAST. CONSTRUCTION DOCUMENTS. E.C. SHALL SUBMIT SHOP DRAWINGS OF ALL EQUIPMENT TO BE INTEGRAL EMERGENCY BACKUP BALLAST TO ILLUMINATE THE FIXTURES IN THE EVENT OF A EQUIPMENT TO BE SALVAGED AND/OR REUSED SHALL BE PROTECTED INSTALLED INDICATING FLOOR PLAN LAYOUT, ELEVATIONS, AND ALL DIMENSIONS FOR APPROVAL., FROM DAMAGE UNTIL REINSTALLED OR THE TIME PERIOD WHEN IT IS 36. NUMBERED CIRCUITS SHOWN ON PLAN ARE FOR THE CONVEYANCE OF DESIGN INTENT ONLY. POWER FAILURE. ALL COMPONENTS SHALL BE IN COMPLIANCE WITH NFPA 101 AND NFPA 70 L8. WHERE MCDONALD'S RESTAURANT HAS A PLAYPLACE, THE EC SHALL COORDINATE EXACT OF THE ENGINEER PRIOR TO INSTALLATION. CODE REQUIRED CLEARANCES IN FRONT OF ALL TURNED OVER TO THE OWNER AND/OR THE PROJECT MANAGER. LL ELECTRICAL EQUIPMENT SHALL BE MAINTAINED AT ALL TIMES. ACTUAL FIELD CONDITIONS WILL AFFECT CIRCUITRY. INDICATE THE ACTUAL CIRCUIT NUMBERS SECTION 700. BALLAST BATTERY SHALL MAINTAIN 87.5% OF THE NOMINAL BATTERY' VOLTAGE / LOCATION OF PLAYPLACE LIGHTING WITH PLAYPLACE TOY VENDOR FOR MAXIMUM INSTALLED ON THE "AS-BUILT" DRAWINGS. AFTER 1.5 HOURS TO COMPLY WITH NEC SECTION 700 AND UL 924. D10. SEE THE GENERAL ELECTRICAL SPECIFICATIONS AND NOTES ON SHEET ILLUMINATION AND SAFETY PER THE FINAL LOCATION OF THE PLAYPLACE TOY. LIGHTING o 9. THE CONTRACTOR SHALL INCLUDE IN BID AN ALLOWANCE FOR THE FOLLOWING ADDITIONAL 49. IDENTIFICATION OF ELECTRICAL ITEMS E100 FOR ADDITIONAL GENERAL REQUIREMENTS. FIXTURES SHALL NOT BE MOUNTED TO THE TOY OR ANY PART OF THE TOY STRUCTURE. LIFE SAFETY DEVICES, INCLUDING INSTALLATION AND ALL CONDUIT AND WIRE, FOR ADDITIONAL 37, BUILDING STANDARDS A. PROVIDE PERMANENT IDENTIFICATION MARKING AND NAMEPLATES FOR ALL CONDUCTORS L9. EC SHALL VERIFY ALL TAP SETTINGS FOR H.I.D. LIGHTING FIXTURES AND MAKE ANY > DEVICES AS MAY BE REQUIRED BY THE REVIEW OF THE AUTHORITY HAVING JURISDICTION. A. ALL NEW CONDUIT RACEWAYS AND BOXES FOR ALL SYSTEMS SHALL BE INSTALLED AND EACH ITEM OF ELECTRICAL APPARATUS AND ASSOCIATED CONTROLLED EQUIPMENT, NECESSARY CORRECTIONS PRIOR TO INSTALLATION. LL (2) EXIT SIGN FIXTURES TIGHT-UP TO THE BOTTOM OF THE STRUCTURAL BEAMS WHERE REQUIRED AND PROPERLY WITH THE SAME INSCRIPTIONS AS SHOWN ON THE DRAWINGS. ALL IDENTIFICATION MARKINGS (2) EMERGENCY LIGHTING FIXTURES SUPPORTED FROM STRUCTURAL MEMBERS. SHALL BE CLEARLY AND NEATLY APPLIED. -� B. APPLY ENGRAVED PLASTIC LAMINATE NAMEPLATES WITH NON-CORRODING TYPE SCREW -" o CONTRACTOR SHALL PROVIDE A UNIT PRICE FOR EACH FOR QUANTITY ADJUSTMENT. B. ALL NEW CONDUIT RUNS SHALL BE INSTALLED ABOVE AND OVER THE TOP OF ALL NEW FASTENERS OR RIVETS TO ALL MOTOR STARTERS, DISCONNECT SWITCHES, RELAYS, REMOTE AND/OR EXISTING DUCTWORK, PIPING, CONDUITS, PULLBOXES, ETC. E.C. SHALL PROVIDE CONTROL PANELS, PUSH BUTTON STATIONS, PANELBOARDS, SWITCHBOARDS, TRANSFORMERS, ALL NECESSARY ACCESSIBLE PULLBOXES. CONDUIT BENDS SHALL NOT EXCEED CODE AND OTHER ELECTRICAL APPARATUS. NAMEPLATES SHALL BE WHITE WITH BLACK CORE, �` `� 10. THE CONTRACTOR SHALL INCLUDE IN BID ELECTRICAL UNIT PRICES (EUP) TO PROVIDE REQUIREMENTS WITHIN A SINGLE RUN. E.C. SHALL PROVIDE ALL PULLBOXES AS REQUIRED. 1 1/4" X 3" MINIMUM WITH 3/16" HIGH LETTERING. THE NAMEPLATE SHALL IDENTIFY: r`� :�'. ' ;''' Li ADDITIONAL LIFE SAFETY DEVICES WITHIN FINISHED CEILING SYSTEMS, INCLUDING ALL CONDUIT - NAME OF DEVICE OR AND WIRE, FOR EACH TYPE OF DEVICE AS SCHEDULED IN NOTE NUMBER 9. THE UNIT PRICE C. NEW CONDUIT RUNS OR PULLBOXES SHALL NOT BE INSTALLED LESS THAN 2 INCHES - LOAD THE DEVICE IS SERVING ABOVE RECESSED LIGHTING FIXTURES UNLESS APPROVED BY THE ENGINEER. j' ' Cljtrs>U1f SHALL INCLUDE ALL GENERAL CONTRACTOR ASSOCIATED COSTS TO INSTALL DEVICES WITHIN C. PROVIDE A TYPEWRITTEN DIRECTORY OF CIRCUITS IN LIGHTING AND POWER PANELS AND INSTALLED CEILING SYSTEMS. D. NEW CONDUIT RUNS OR PULLBOXES SHALL NOT BLOCK OR PREVENT FULL AND COMPLETE PROVIDE PANEL IDENTIFICATION IN BLACK ALKYD PAINT STENCILED INSCRIPTIONS ON THEiu�= 11. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, MAKE A ACCESS AND OPERATION OF NEW OR EXISTING HVAC EQUIPMENT, ACCESS DOORS, PIPING INSIDE OF THE DOOR, DIRECTLY ABOVE THE CENTERLINE OF THE DIRECTORY FRAME, OR VALVES, JUNCTION BOXES, DUCT HEATERS, MAIN SUPPLY AND RETURN AIR DUCTS, ON THE VERTICAL AND HORIZONTAL CENTERLINE OF DOORS WITHOUT DIRECTORY FRAMES. SCHEDULED ARRANGEMENT WITH THE PROJECT MANAGER TO VISIT THE SITE, AND THOROUGHLY „ , PULLBOXES, CLEANOUTS, ETC. D. PROVIDE ON DEVICE PLATES FOR LOCAL TOGGLE SWITCHES, TOGGLE SWITCH MANUAL °° BECOME FAMILIAR WITH THE BUILDING STANDARDS AND LOCAL CONDITIONS RELATING TO THE STARTERS, PILOT LIGHTS AND OTHER ELECTRICAL ITEMS, WHOSE FUNCTION IS NOT READILY U w a WORK. FAILURE TO DO SO WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF ? o THE CONTRACT. APPARENT, ENGRAVED SUITABLE INSCRIPTIONS OR PLASTIC LAMINATE NAMEPLATES i_ F E. NEW CONDUIT AND PULLBOXES TO BE INSTALLED BELOW NEW OR EXISTING DUCTWORK DESCRIBING THE EQUIPMENT CONTROLLED OR INDICATED. w� o 12. THE CONTRACTOR SHALL PROVIDE TEMPORARY POWER AND WIRING FOR THE PERFORMANCE SHALL BE MOUNTED TIGHT UP TO BOTTOM OF DUCT WITH 90 DEGREE BENDS UP SIDEWALL E. EMBOSSED SELF-ADHERING PLASTIC TAPE LABELS WILL NOT BE ACCEPTED. F z Z OF ALL TRADES, FOR THE ENTIRE PERIOD OF CONSTRUCTION AND SHALL REMOVE ALL OF DUCT TO MEET REQUIREMENTS OF LETTER C ABOVE. SUPPORTS SHALL NOT ± u a TEMPORARY WIRING AT THE COMPLETION OF CONSTRUCTION. ALL COSTS FOR ESTABLISHING PENETRATE DUCTWORK, AND SHALL BE INDEPENDENT OF ALL DUCTWORK SUPPORTS. 50. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL EXISTING OR NEW NON-ACCESSIBLIE SYSTEM r i w �z AND REMOVING TEMPORARY POWER SHALL BE INCLUDED IN BID. DIRECT CONTACT OF CONDUIT RACEWAY SYSTEMS WITH DUCTWORK OR PIPING SHALL BE DEVICES, PULLBOXES, AND EQUIPMENT, ETC. FOR RELOCATION TO ACCESSIBLE CEILING AREAS. z ~W T PROVIDED WITH VIBRATION SEPARATION METHOD APPROVED BY THE ENGINEER. E.C. SHALL-INCLUDE ALL COMPLETE COSTS FOR RELOCATION AND VERIFY SUCH CONDITIONS z o a 13. THE EXISTING POWER, SIGNAL, AND COMMUNICATIONS SYSTEMS ARE TO REMAIN IN SERVICE WITH ARCHITECTURAL CEILING PLANS PRIOR TO FINAL BIDS. w u w TO PROVIDE FOR THE OWNER'S EXISTING FUNCTIONS. SHOULD IT BECOME NECESSARY TO F. NEW CONDUIT AND BOXES TO BE INSTALLED WITHIN ALL EXISTING FINISHED BUILDING SHUT-DOWN ANY SYSTEM OR PORTION OF A SYSTEM, APPROVAL IN WRITING MUST BE DRYWALL, FURRED BUILDING WALLS, PARTITIONS, AND COLUMNS SHALL BE INSTALLED WITH 51. EXISTING CONDITIONS OF ALL EXISTING BUILDING EQUIPMENT, DEVICES, FIXTURES, ANID z o OBTAINED FROM THE PROJECT MANAGER AND SHALL BE ONLY FOR THE PERIOD AND TIME EMT AND FLEXIBLE RACEWAYS NOT MORE THAN 6'-0" LONG. ELECTRICAL CONTRACTOR SYSTEMS THAT REQUIRE REWIRING, REUSE, RELOCATION, OR REFURBISHING AS PER DRAWINGS p ' AGREED UPON. THE BID IS TO INCLUDE THE COST OF ANY TEMPORARY WIRING AND SHALL INCLUDE ALL COSTS FOR DRYWALL ACCESS, CUTTING, PATCHING, PAINTING, ETC. IN AND SPECIFICATIONS SHALL BE FIELD VERIFIED BY THE E.C. PRIOR TO COMMENCEMENT OF PREMIUM TIME REQUIRED FOR THE SHUTDOWN. BIDS FOR SUCH CONDITIONS. FIELD VERIFY ALL LOCATIONS ON SITE PRIOR TO FINAL ANY WORK TO BE COMPLETELY OPERATIONAL. E.C. SHALL SUBMIT A WRITTEN STATEMENT AND � a o BIDS. EXCEPTIONS DURING BIDS SHALL BE SUBMITTED IN WRITING. ITEMIZED LISTING OF ALL EXISTING CONDITIONS OF THE FOLLOWING, ALTHOUGH NOT LIMITED m U S 14. ALL MATERIALS AND EQUIPMENT SHALL BE ERECTED, INSTALLED, TOOLED, CONNECTED, TO THOSE LISTED: w a CLEANED, ADJUSTED, TESTED, CONDITIONED, AND PLACED IN SERVICE IN ACCORDANCE WITH G. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL BE HELD RESPONSIBLE TO HAVE o ~ m ° THE MANUFACTURER'S DIRECTIONS AND RECOMMENDATIONS. EXAMINED THE CONSTRUCTION SITE WITH RESPECT TO CONSTRUCTION DRAWINGS, ACTUAL A. HVAC EQUIPMENT < U o 15. ALL CUTTING, DRILLING, AND PATCHING OF MASONRY, DRYWALL, CONCRETE, STEEL, OR IRON FIELD CONDITIONS, DOOR FRAME HEIGHTS, PIPING OBSTRUCTIONS, DUCTWORK HEIGHTS AND B. EXIT SIGNS AND EMERGENCY LIGHTING FIXTURES 5 WORK BELONGING TO THE BUILDING SHALL BE DONE BY THIS CONTRACTOR IN ORDER THAT LEVELS, FLOOR LEVELS, CEILING HEIGHTS, ETC. PRIOR TO FINAL BIDS. C. LIFE SAFETY/FIRE ALARM SYSTEM DEVICES a Q a WORK MAY BE PROPERLY INSTALLED. UNDER NO CONDITIONS MAY STRUCTURAL WORK BE H. ALL NEW BUILDING STANDARD EQUIPMENT, DEVICES, AND MATERIALS SHALL BE EQUAL TO D. LIGHTING AND RECEPTACLE DEVICES. CUT, EXCEPT AT THE DIRECTION OF THE ARCHITECT/ENGINEER OR THEIR REPRESENTATIVE. OR GREATER IN QUALITY TO EXISTING APPROVED BUILDING STANDARD MATERIALS 9o PRESENTLY INSTALLED IN BUILDING. EQUIPMENT, DEVICES, AND MATERIALS SHALL BE THE WRITTEN STATEMENT SHALL BE SUBMITTED TO THE PROJECT MGR., ARCHITECT, AND o > ° ° o ° 16. SHOP DRAWINGS SHALL INCLUDE MANUFACTURER'S NAMES, CATALOG NUMBERS, CUTS, L ° C .N DIAGRAMS, AND OTHER SUCH DESCRIPTIVE (DATA AS MAY BE REQUIRED TO IDENTIFY AND SUBJECT TO THE APPROVAL OF THE ARCHITECT, PROJECT MANAGER, AND THE ENGINEER. ENGINEER PRIOR TO WORK. IN THE EVENT THAT THE CONTRACTOR COMMENCES WORK a ° a o °o E.0 0 WITHOUT SUBMITTAL, THE CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY AND COST TO REVIEW THE EQUIPMENT. SUBMITTALS SHALL BE IN LOGICAL GROUPS (FOR EXAMPLE ALL I. ALL EMERGENCY AND EXIT SIGN JUNCTION BOXES SHALL BE PAINTED RED. PANEL TAG v° Q a 0)° MAINTAIN THE ABOVE IN GOOD WORKING ORDER AND CONDITION. a ° ° LIGHTING FIXTURES). PARTIAL SUBMITTALS WILL NOT BE REVIEWED. AND CIRCUIT NUMBER FOR ALL WIRING WITHIN JUNCTION BOX SHALL BE INDICATED ON � o oa o u a o COVER. -0 ° ° ° 17. SUBMIT FOUR (4) COPIES OF THE FOLLOWING SHOP DRAWINGS FOR REVIEW: 52. E.C. SHALL REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF ALL ELECTRICAL ° 0 °' E o a J. ALL JUNCTION BOXES SERVING LIGHTING AND POWER SHALL HAVE CIRCUIT NUMBERS AND ° ■+ ° •a N a m A. LIGHTING FIXTURES AND LAMPS AND COMMUNICATIONS OUTLETS. ELECTRICAL ENGINEERING DRAWINGS SHALL BE USED FOR ocn PANEL TAGS FOR ALL WIRING WITHIN JUNCTION BOX INDICATED ON COVERS. ° U � a i B. WIRING DEVICES CIRCUITING INFORMATION ONLY. o ° C. LOW VOLTAGE RELAYS AND SWITCHES 38. A NEW PANELBOARD COPPER GROUND BUS SHALL BE INSTALL FOR EQUIPMENT GROUNDING 53. E.C. SHALL REFER TO MECHANICAL AND PLUMBING ENGINEERING DRAWINGS FOR EXACT o c E. DIMMERS AND CONTROLS REQUIREMENTS FOR ALL PANELBOARDS LACKING A GROUND BUS. LOCATIONS OF ALL MECHANICAL AND PLUMBING EQUIPMENT. o o 5 ° a o ° O ° 39. PERFORM ALL WORK OF A DEMOLITION NATURE THAT MAY BE REQUIRED OR NECESSARY FOR ° - u 0 ° °o 18. CONTRACTOR SHALL PROVIDE "AS-BUILT" DOCUMENTATION AND HARD COPY REPRODUCIBLE THE FULL AND COMPLETE EXECUTION OF THE WORK, WHETHER EXPLICITLY SHOWN AND/OR o o ° ° c V U p Q ° DRAWINGS AT THE COMPLETION OF THE PROJECT AND SUBMIT TO THE ARCHITECT AND THE SPECIFIED OR NOT. EXACT EXTENT OF DEMOLITION WILL NOT BE FULLY INDICATED BY " ° -° 0 .�'� E c ENGINEER. AS-BUILT DRAWINGS SHALL INDICATE EXACT CIRCUIT NUMBERS, LOCATIONS OF DRAWINGS. DETERMINE THE NATURE AND EXTENT OF DEMOLITION THAT WILL BE NECESSARY ° 0 0 0 Y - ° CD ALL DEVICES, CEILING FIXTURES, AND RACEWAY FOR LIGHTING, TELECOMMUNICATIONS AND BY COMPARING THE CONTRACT DOCUMENTS WITH ARCHITECTURAL AND DEMOLITION DRAWINGS ..�. c U r " a ° U co POWER DISTRIBUTION SYSTEMS AS INSTALLED. TO EXISTING CONDITIONS. ELECTRICAL EQUIPMENT WHICH WILL NOT BE REUSED SHALL BE ( � -i~ - TURNED OVER TO THE OWNER OR REMOVED FROM THE PREMISES AS DETERMINED BY THE c U ° u a 19. ALL MATERIAL, EQUIPMENT, WIRING DEVICES, ETC. SHALL BE NEW AND OF COMMERCIAL GRADEun .° ° PROJECT MANAGER. UNLESS SPECIFICALLY INDICATED AS EXISTING TO BE REUSED ON DRAWINGS. ® a o o a 40. ANY EXISTING ELECTRICAL MATERIAL AND EQUIPMENT WHICH INTERFERES WITH THE NEW � .o •__ ° c 20. EXCEPT AS NOTED OTHERWISE, ALL WORK REQUIRED FOR THE ELECTRICAL INSTALLATION AS ADDITION OR THE REMOVAL OF EXISTING WALLS SHALL BE REMOVED OR RELOCATED BY THE 13c - a (n E CONTRACTOR. VERIFY REMOVAL AND NEW LOCATION OF EQUIPMENT WITH THE PROJECT ° o o "' 1),2 a 0 SHOWN ON DRAWINGS SHALL INCLUDE ALL LABOR, INSTALLATION METHODS, EQUIPMENT, AND U o MATERIALS AND SHALL BE IN STRICT COMPLIANCE WITH ALL BUILDING STANDARDS. MANAGER AND THE ARCHITECT/ENGINEER PRIOR TO WORK. T� O 3 w �'3 U 21. PROVIDE A COMPLETE METAL RACEWAY SYSTEM, FITTINGS AND ENCLOSURES FOR ALL o ® o ° ° ° ° o ELECTRICAL WIRING SYSTEMS TO BE INSTALLED FOR THE PROJECT. SYSTEMS SHALL INCLUDE, w ° J N C BUT NOT BE LIMITED TO POWER, COMMUNICATIONS, SECURITY, PAGING, TEMPERATURE a N Q� N° o CONTROL AND CONTROLS. °` o ° a 3 w c F u CL 22. NOT USED. zitz L'i< } o u 't 23. MINIMUM CONDUIT SIZE SHALL BE 1/2 INCH FOR GENERAL LIGHTING AND POWER CIRCUITRY LJ °' w o Q V) oN o UNLESS OTHERWISE INDICATED AND/OR REQUIRED BY CODE. � CL D `' \ of N Q F- � U w � j 't- a 24. FLEXIBLE CONDUIT CONNECTIONS TO RECESSED LIGHTING FIXTURES SHALL BE MADE WITH o - Q` w � Q \ 0 � FLEXIBLE STEEL CONDUIT, 1/2 INCH MINIMUM, INCLUDING AN INSULATED COPPER GREEN a o EQUIPMENT GROUNDING CONDUCTOR OR SHALL BE MADE WITH METAL CLAD TYPE CABLE. CN 25. NOT USED. rn 26. WIRE NUMBER 8 AND SMALLER FOR USE IN INTERIOR DRY LOCATIONS SHALL BE TYPE THWN z THERMOPLASTIC 600 VOLT INSULATED COPPER CONDUCTORS. FEEDERS AND POWER WIRING NUMBER 6 AND LARGER SHALL BE TYPE THW 600 VOLT INSULATED COPPER. WIRE WHICH IS INSTALLED IN RACEWAY IN MOIST OR DAMP LOCATIONS SHALL BE THW, 600 VOLT INSULATED COPPER CONDUCTORS. NO WIRE SMALLER THAN NUMBER 12 AWG SHALL BE USED FOR LIGHTING OR POWER 27. BRANCH CIRCUIT HOMERUN WIRING: A. GENERAL PURPOSE BRANCH CIRCUIT HOMERUNS CONSISTING OF TWO NETWORKS Li SHALL HAVE PHASE, NEUTRAL AND GROUND CONDUCTORS INCREASED TO NUMBER Q 10 AWG, THWN AS A MINIMUM. WHERE HOMERUN (ONE OR MORE NETWORKS) zo N EXCEEDS 100 LINEAR FEET, CONDUCTOR SIZE SHALL BE INCREASED ONE TRADE C� z Q z SIZE. Z B. ALL BRANCH CIRCUITS, FEEDERS, AND HOMERUNS SHALL BE PROVIDED WITH ANJ $ INSULATED COPPER GREEN GROUNDING CONDUCTOR ROUTED IN THE SAME J Q w fl� CONDUIT. GROUNDING CONDUCTOR SHALL BE SIZED PER THE REQUIREMENTS OF - a a c NEC SECTION 250. LL_ � a C. HOMERUN LENGTH SHALL BEGIN AT THE CENTRAL POINT OF ALL DISTRIBUTED L- m z L� wLo o CIRCUITS TO THE PANELBOARD CIRCUIT BREAKER. O O - O °c co W - Q w 28. ALL NEW CIRCUIT BREAKERS FOR EXISTING PANELBOARDS AND DISTRIBUTION PANELBOARDS z w Ln SHALL MATCH EXISTING BUILDING PANELBOARD MANUFACTURER AND CIRCUIT BREAKER TYPE. w ALL CIRCUIT BREAKERS SHALL BE BOLT ON TYPE. AIC RATING OF NEW CIRCUIT BREAKER a_ � SHALL MATCH AIC RATING OF PANELBOARD IN WHICH IT IS INSTALLED. WHERE SERIES RATED O X N O x TYPE CIRCUIT BREAKERS ARE USED, NEW CIRCUIT BREAKERS SHALL BE INSTALLED SO AS TO r~- N Lv o U w MAINTAIN THE UL SERIES RATING OF THE ENTIRE SYSTEM. THE CONTRACTOR SHALL PROVIDE A NEW TYPEWRITTEN PANEL DIRECTORY FOR EACH PANEL CHANGED AT THE COMPLETION OF 031 .1745.00.0 THE PROJECT. EACH CIRCUIT BREAKER SHALL BE LABELED TO IDENTIFY LOAD TYPE AND z LOCATION. E 1 Li • cn GENERAL NOTES TT_ m z 0 FIELD VERIFY LOCATIONS OF EXISTING POWER PANELS w 0 AP-2 L AP-1 - - \ - _J LLl 0 \ E1 I1 1I -- II II I1 a Fel w 00 it _ II ii cl IMR II II NEW 225A 3PH 120/208V 42 -- 2 ii .o f�4,Qr Uf'i`��``� SPACE PANEL AP-3. CONFIRM LOCATION WITH ACM. FIELD ° • - ,r ,,�4 �� VERIFY 3'-0" NEC WORKING _ �. : " ' ''" Cf VI CLEARANCE. REFER TO ONE LINE .- DIAGRAM ON SHEET E4.1 Ni //� { +,.•: f ,c- Fo� Y, ol NEW PANEL 900.60 E1 O E4 7=ft UE On _`" T °pN AP-3 E1 O E] Q 152.06 E1 ® L DELL o r U F-� - - - - AP-3:21 " . , ... z Woo G� U Z JIF E2 •• o o (�i �+ E1 O O Uvo E5 ° '' w �Z� AP-3:27 E1 li - 900.51 E1 g z ago E7 - --- u I Fe 1 € W z M xx xE5 E6 l u iE4,w w °W a E:� Fol C Ot_P E1 - z E1 - -,900.51 E1 ¢ o E1 0 --J ° E1 'I i i O ED O O t 0 o o n E1 0 o 900.82 E1 I o \ I I O O wHco 900.2 E1 E2 E3 I a I ® • m z215.04 E1 Feel Q 143.00 E3 , -� a U 00.8 E1 77.06 E1 215.04 E2 ® E � 2 . 0 9 .35 E1 800.46 E1 I 219.00 E 1 11 �_ i NEW ELECTRICAL a - Q mg 0_0 RECEPTACLE FOR ORB. O O UE OE= VERIFY LOCATION IN 7-7 Oa E1 1 p CEILING o i o w ° 215.04 1 - 00 I w 1 216.05 E1 DUAL POINT FRONT a o o p o o COUNTER LAYOUT CONFIRM o ° °- p U o L LQ) D E-0 0 a- o ° O N p �' �i n i � LAYOUT WITH MCD � � ° � o ° � � I 219.00 E1 1 , 216.04 E1 CONSTRUCTION SUPERVISOR 219.00 E2 NEW RECEPTACLES REFER TO DETAIL ON a ° ° E n- C) .� 3 •- cn I 1 r FOR MINI ORB SHEET E4.1 0 ^ _ °-�, N '" o ' o _ L TD-UGC F- __ r 700.09 E1 '� U ° L ` ° 97 12 216.00 E9 ° � �� 1 127.00 E2 AND SCANNER 122.26 E1 213.00 E4 ` E6 �\ ° ♦ o° c a CD �j ----i - \� 990 E1 N 0 o o oL o� � - 0 0 0 0 0 0 - -7 Fo� � a) p 0 0 0 C O 'n r_1 o ° ° v o o o"o�o o 0 D*- a -p O _cn s= O C p C U C X - 0 C) O +� X Lt- EEEEEE�m n O U C N L N •o •0 J~ .c Q) O O N 215.04 El 215.04 G ID E2 901.28 E1 901.20 E1 Q �.� o p o Q U N �- C O U (n 215.06 E1 901.28 E1 901.20 E1 ® _p 215.06 E3 E I REFER TO SHEET E3.2 FOR ROUGH IN SCHEDULE ° o° o N ` ° a o Q U r IE o n ° a C �Q o I ■s 3 U L� O 030 :o ' 02 . � D ® O > O W N p N C N 0 v . .0 U a N p N i N SYMBOLS AND ABBREVIATIONS 1 ELECTRICAL POWER PLAN � H o_ 3 co E3. 1 1 /47) _ � ,_0„ Q m o L SYMBOL DESCRIPTION SYMBOL DESCRIPTION m o 0 o Q o Li Ln Q ° � = w � � w i k� SINGLE POLE SWITCH, 3W=THREE WAY SWITCH, K=KEYED SWITCHED B BUZZER o o � � (f) o \ CD FOR BUZZER Q � o ❑T TRANSFORMER © a co L=o cf) p v JB WITH DUPLEX CONVENIENCE OUTLET (FLUSH WITH CEILING) PULLBOX KEY NOTES GENERAL NOTES N �{ JB WITH SINGLE CONVENIENCE OUTLET w=__ PANELBOARD FE1 EXISTING TO REMAIN IN THIS AREA, UNLESS OTHERWISE NOTED. SEE ELECTRICAL PANEL SCHEDULE FOR PANEL & CIRCUIT BREAKER JB WITH DUPLEX CONVENIENCE OUTLET O CIRCUIT BREAKER 1. JB WITH TWO DUPLEX CONVENIENCE OUTLETS ASSIGNMENT, VOLT/PH, FLA, BREAKER SIZE, COND/WIRE, RECEPTACLE z A AMPERES F ] E2 REUSE EXISTING CIRCUITRY FOR ALL RELOCATED EQUIPMENT. FIELD VERIFY TYPE, HEIGHT ABOVE FINISHED FLOOR, REQUIREMENTS & REMARKS FOR Y O JB WITH FLUSH FLOOR MOUNTED OUTLET ACM AREA CONSTRUCTION MANAGER EXISTING CIRCUITRY AND COORDINATE WITH KITCHEN DRAWINGS. ALL ELECTRICAL EQUIPMENT. JB WITH SPECIAL PURPOSE OUTLET AFF ABOVE FINISHED FLOOR E3 ALL 120V 15A AND 20A RECEPTACLES IN THE KITCHEN AREA AND WITHIN ® JB WITH ISOLATED GROUND OUTLET .� • CCT CIRCUIT C CONDUIT6' OF A SINK SHALL. HAVE GFCI PROTECTION, IG471 0, 9 =IG5261 , '� =IG4700A, =IG5262 PROVIDE POWER AND DATA WITHIN CEILING FOR CONNECTION TO SELF w E4'•' ORDER KIOSKS. COORDINATE EXACT LOCATION OF KIOSKS WITH DECOR I> INTERCOM STATION W/ 3/4"C- TO MAIN STATION EC ELECTRICAL CONTRACTOR DRAWINGS. PROVIDE 2#12, 1#12 GRD., & 1#12 ISOLATED GROUND ON A z Q N TELEPHONE JACK 20A DEDICATED CIRCUIT FED FROM THE CP PANEL FOR EVERY TWO (2) O � z r GC GENERAL CONTRACTOR KIOSKS. IF THERE IS NOT SUFFICIENT SPACE FOR THE NEW COMPUTER z of Lj z O JUNCTION BOX - WALL OR CEILING MOUNTED GFI/GFCI GROUND FAULT CIRCUIT INTERRUPTER CIRCUITS. THEN THE �;f�NTRACTOR IS TO REPLACE THE EXISTING PANEL J D S Ll w DISCONNECT SWITCH GND GROUND WITH ANEW 42 CIRCUIT PANEL OF THE SAME AMPACITY AS EXISTING. NEW _ a a PANEL SHALL BE OF THE SAME MAKE, MODEL AND HAVE THE SAME A/C o w o SO STUB UP THRU ROOF IG ISOLATED GROUND RATING AS THE PANE_ BEING REPLACED, LL m � a O THERMOSTAT SENSOR W/ 1/2"C- UP TO CEILING SPACE JB JUNCTION BOXz obi [E5] NOT USED. 0 O Qw c MOTOR CONNECTION KES KITCHEN EQUIPMENT SUPPLIER W z z z PROVIDE 2 WALL MOUNT DEDICATED QUAD ISOLATED GROUND RECEPTACLES �O LD � w CONDUIT RUN CONCEALED IN CEILING OR WALLS MLO MAIN LUGS ONLY E6 a � -_ � > w o - (IG5262) FOR TABLE LOCATOR EQUIPMENT AND NEW TWIST LOCK O X a RECEPTACLE IC4700 FOR KVS MONITORS, INSTALL BEHIND MENU BOARD -i N W w W L , / \ CONDUIT RUN IN FLOOR SLAB WP WEATHERPROOF VALANCE. PROVIDE JUNCTION BOX FOR CABLE TRANSITIONS TO ABOVE o OT MANUAL SWITCH (T=THERMAL OVERLOADS) CEILING. o 031 .1745.00.0 1X HOT (SHORT), NEUTRAL (LONG), EQUIP GRD (LONG WITH DOT), & o & 'X' DENOTES ISOLATED GRDFE7 ROUGH-IN FOR FUTURE DIGITAL BULLETIN BOARD, CONFIRM LOCATIONS z � J-BOX WITH FINAL EQUIPMENT CONNECTION 1 WITH ACM. E3s V) POWER PLAN M PB Pullbox VIF a Verify In field ELECTRICAL SCHEDULE PB = Pullbox vIF = Verify in Field ELECTRICAL S C H E D U L_ E JB -Junction Box EC =Electrical Contractor J B = Junction ox ITEM # TAG # QTY DESCRIPTION VOLT/PHASE AMPS PANEL CIRCUIT HP RECEPT TYPE BRKR SIZE COND / WIRE HGT AFF SPECIAL REMARKS EC = Electrical Contractor 23.57 023.57E1 1 CREAM DISPENSER - DOUBLE WIDE 120/1 1.0 AP-3:3 - 5-20R 20A 1/2"C-2#12 2'-3" - 36" NEXT GEN 3-PLATEN CLAMSHELL GRILL - 208/3 24.0 AP-3:37,39,41 - BY KES 30A 1/2"C- 3#10EA SEE RMKS PLUGS IN RACEWAY RECEP WITH(1)L21-20P TAG # QTY DESCRIPTION VOLT/PH FLA BRK SIZE COND/WIRE PNL/CCT RECEP TYPE HGT AFF REQUIREMENTS & REMARKS 96.14 096.14E1 1 GAS/ELECTRIC INTERLOCK& (1) 15-30P POWER PLUG EA GRILL 213.00E4 1 TABLE LOCATOR SYSTEM 120/1 1.5 20A 1/2"C-2#121G AP-3:22 IG5262 7'-9" FOR GATEWAY AND ROUTER 97.12 097.12E1 1 COMBINATION FREEZER/COOLER 120/1 4.6 AP-3:14 1/3 SEE RMKS 20A 1/2"C-2#12 SEE RMKS UNIT PLUGS INTO RACEWAY RECEPTACLE ISOLATED PLUGS INTO OVERHEAD RECEPTACLE # 33006W(B) 216.00E9 1 POS - VIDEO MONITOR 120/1 1.5 20A 1/2"C-2#121G AP-3:28 (2) IG4700 FLUSH ON - 122.26 122.26E1 1 50" TOASTER TABLE W/-POWER - PIN & SLEEVE 208/1 1 24.0 AP-3:(6,8)(10,12) - SEE RMKS (2)30A 1/2"C-2#10 5'-6" PROVIDED BY KES- HEIGHT TO BOTTOM OF ISOLATED CLG RECEPTACLE PLUGS INTO OVERHEAD RECEPTACLE #32006W -7 127.00 127.00E2 1 BUN TOASTER W/ BUTTER WHEEL 208/1 15.8 AP-3:(2,4) _ SEE RMKS 20A 1/2"C-2#12 5'-6" PROVIDED BY KES - HEIGHT TO BOTTOM OF RECEPTACLE 143.00 143.00E3 1 EGG STATION - MANUAL - P&S 208/1 15.1 AP-3:(16,18) - BY KES 20A 1/2"C-2#12 5'-6" PROVIDEKES TO -RECEPTACLE - HEIGHT BOTTOM OF RECEPTACLE TO 152.06 152.06E1 1 WAREWASHER - UNDERCOUNTER 120/1 12.0 AP-3:5 1 5-20R 20A 1/2"C-2#12 1'-6" - z 177.06 177.06E1 1 REACH-IN TOMATO COOLER-SINGLE WIDE RH 120/1 5.8 AP-3:1 1/3 5-20R 20A 1/2"C-2#12 7'-6" - 207.31 207.31 E1 1 CYT DESSERT BLENDER 120/1 1.2 AP-3:7 - 5-20P 20A 1/2"C-2#12 2'-8" - 207.32 207.32E1 1 CYT DESSERT CHILL UNIT 120/1 2 AP-3:11 - 5-20P 20A 1/2"C-2#12 2'-8" - 215.04 215.04E1 3 POS - KVS MONITOR 120/1 ISOLATED 3.0 AP-3:3 - IG4700 20A 1/2"C-2#121G @ CLG 1.5 EACH MONITOR CABLE FURNISHED AND INSTALLED BY POS 215.04 215.04E2 4 POS - KVS MONITOR DATA CABLE - SEE REMARKS - - - - ® CLG SUPPLIER w 215.04 215.04E5 1 POS - KVS MONITOR 120/1 ISOLATED 1.5 AP-3:3 - IG4700 20A 1/2"C-2#121G 6'-1" FOR WALL MOUNTED CYT KVS MONITORS 215.06 215.06E1 1 CYT GRILL SEAR TIMER 120/1 ISOLATED 1.5 AP-3:9 - IG4700 20A 1/2"C-2#121G CLG 215.04 215.06E3 1 CYT GRILL SEAR TIMER DATA CABLE - SEE REMARKS - - - - ® CLG CABLE FURNISHED AND INSTALLED BY POS SUPPLIER 216.04 216.04E1 1 ORB MONITOR (MINI) & SCANNER 120/1 ISOLATED 1.5 EA AP-3:15 - 5-15R IC4700 20A 1/2"C-2#121G 1'-6" - 216.05 216.05E1 1 ORB MONITOR 120/1 ISOLATED 1.5 EA AP-3:15 - L5-15R IG4700 20A 1/2"C-2#121G FLUSHON - 219.00 219.ODE1 2 POS - RECEIPT PRINTER 120/1 ISOLATED 0.7 AP-3:15 - IC4700 20A 1/2"C-2#121G @ CLG - 219.00 219.00E2 2 POS - RECEIPT PRINTER DATA CABLE - SEE REMARKS - - - - @ CLG CABLE FURNISHED AND INSTALLED BY POS SYSTEM SUPPLIER 219.00 219.00E5 1 POS - RECEIPT PRINTER 120/1 ISOLATED 0.7 AP-3:15 - IG4700 20A 1/2"C-2#121G 5'-6" EXTEND 2" CONDUIT ABOVE CEILING. CABLE 219.00 219.00E6 1 POS - RECEIPT PRINTER DATA CABLE - SEE REMARKS - 4x4x4 PB - - 5'-6" FURNISHED AND INSTALLED BY POS SYSTEM SUPPLIER 700.09 700.09E1 1 ECONOMY OEP BOX W/MOUNTING HARDWARE - - SEE REMARKS - BY KES - - SEE RMKS CEILING MOUNTED 701.34 701.34E1 1 DCO - FOR HIVE CYT EQUIPMENT 120/1 10.0 AP-3:20 - 5-20R 20A 1/2"C-2#12 SEE RMKS MOUNTS TO BACK OF HLZ CABINET - FOR TABLE LOCATOR SYSTEM AND HIVE MONITOR w _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES Q 0 900.27 900.27E1 1 RELOCATED ECONOMY OEP BOX - - REUSE EXIST. CKT. - - - - AS REQUIRED GC TO VERIFY AND REWORK ALL EXISTING UTILITIES 900.33 900.33E1 1 RELOCATED BUN TOASTER - - REUSE EXIST. CKT. - - - - - AS REQUIRED GC TO VERIFY AND REWORK ALL EXISTING UTILITIES w 900.35 900.35E1 1 RELOCATED Q'ING OVEN - - REUSE EXIST. CKT. - - - - - AS REQUIRED GC TO VERIFY AND REWORK ALL EXISTING UTILITES 900.45 900.45E1 1 RELOCATED FILET BUN STEAMER - - REUSE EXIST. CKT. - - - - - AS REQUIRED 900.46 900.46E1 2 RELOCATED/REDESIGNED KVS SYSTEM VERIFY VERIFY REUSE EXIST. CKT. - VERIFY - - - KVS/POS INSTALLER TO USE DED CIRCUIT/DATA `S ��F•�' POS INSTALLER TO USE DED CIRCUIT AND/OR DATA � r"hCU, 900.51 900.51 E1 4 RELOCATED/REDESIGNED POS SYSTEM VERIFY VERIFY REUSE EXIST. CKT. - VERIFY - - - CHASE # 9.14 IF SUPPLIED GC TO VERIFY AND REWORK ALL EXISTING UTILITIES 900.57 900.57E1 2 RELOCATED COFFEE BREWER - - REUSE EXIST. CKT. - - - - - AS REQUIRED �(, ( '4 GC TO VERIFY AND REWORK ALL EXISTING UTILITIES 900.60 900.60E1 1 RELOCATED BLENDER - COUNTERTOP - MCFLURRY - - REUSE EXIST. CKT. - - r a�.1 - - - AS REQUIRED GC TO VERIFY AND REWORK ALL EXISTING UTILITIES to ;a. �:. i, i 900.82 900.82E1 1 RELOCATED GREASE (REMOVAL MACHINE - - REUSE EXIST. CKT. - - - - - AS REQUIREDr� � `�' ''�% C��I tt1§ GC TO VERIFY AND REWORK ALL EXISTING UTILITIESf i, of3v6ljifn ` 900.85 900.85E1 1 RELOCATED MUFFIN TOASTER - - REUSE . CKT. - - - - - AS REQUIRED 4 _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES �t�f�r\'t.� IISiI� 900.92 900.92E1 1 RELOCATED SHAKE/SUNDAE MACHINE - - REUSE EXIST. CKT. - - - - AS REQUIRED 901.20 901.20E1 2 RELOCATED SPECIALTY COFFEE MACHINE 208/1 - REUSE EXIST. CKT. - L5-30R 30A - SEE RMKS A TO PROVIDE PLUG AND WIRE FROM NEAREST :; AVAILIBLE POINT �o GC TO VERIFY AND REWORK ALL EXISTING UTILITIES U w a 901.23 901.23E1 1 RELOCATED SPECIALTY COFFEE WORKTOP _ - REUSE EXIST. CKT. - - - - - REFRIGERATOR AS REQUIRED GC TO VERIFY AND REWORK ALL EXISTING UTILITIES z Lu� o 901.28 901.28E1 2 RELOCATED BLENDED ICE MACHINE - - REUSE EXIST. CKT. - - - - - AS REQUIRED _ ..•. Z �wz _ =pZ z UUO r W I-Z N LLJJ ¢Fw0 V W Z Z) Z 05< NOTE w pW o Q DETAILS SHOWN ARE TYPICAL _ � CONFIGURATION ONLY. SITE SPECIFICS 'a o MIGHT CAUSE DEVIATIONS. � 0 M U �o W 5 v p mor. W 1- mZo �fy't�s �: -F'. r an a U 0 c I Q Lia c � m a O U L �p� Z3 ID --- ------ - -__-- --.._--------- - - - .� C _ N � O C �0 L° JB Pullbox NF Veriify in Field ELECTRICAL SCHEDULE _ _ JR Junction Box p a 2 O N � U EC Electrical Contractor ) O U N U O Q N B � O U TAG # QTY DESCRIPTION VOLT/PH FLA BRK SIZE CoND/WIRE PNL/CCT RECEP TYPE HOT AFF REQUIREMENTS & REMARKS SLIP SHEET PROVIDES GENERAL GUIDANCE l� ° a ° ° 004.20E1 3 MENU BOARD - DIGITAL - 5EEQ 120/1 2.1 EA 20A - - (2) IG5262 SEE PLAN SEE LAYOUT FOR GANGED OUTLET CONFIGURATION ISOLATED SITE SPECIFIC ADAPTATIONS MAY BE REQUIRED ° o � 004.21E1 1 MENU BOARD - DIGITAL - !MEDIA PLAYER 120/1 1.0 EA 20A - - (2) IG5262 SEE PLAN SEE LAYOUT FOR GANGED OUTLET CONFIGURATION O In Q. m '-' p •- ISOLATED _ � - O U L 004.21 E2 1 MENU BOARD - DIGITAL-(MEDIA PLAYER DATA CABLE - - - - JB SEE PIAN JB W/ 23•C. TO TERMINATE ABOVE CEILING W/ BUSHINGS FOR O U C N U N 01 DATA CABLES. SUPPLY W/ GROMMETED OPENING IN COVER PLATE +�_° s C•� 004.21 E9 2 MENU BOARD - DIGITAL -IMEDIA PLAYER DATA CABLE - - - - JB SEE PLAN JB W/ 2}- C. TO TERMINATE ABOVE CEILING W/ BUSHINGS FOR DATA CABLES. SUPPLY W/ GROMMETED OPENING IN COVER PLATE 7 O•- U � ° C O- fn DIGITAL MENU BOARD N 0 °�.3 ° O ° C O -0 -C VERTICAL DIMENSIONS WHEN POSSIBLE SECURE AT LEAST ONE BRACKET PER MENU SECTION TO A STUD PROVIDED AQEQUATE BRACKET BRACKET DETAIL s o•° ° o ° REFERENCED wo SPACING CAN BE MAINTAINNED. ALL OTHER BRACKETS ARE TO BE SECURED TO PLYWOOD BACKING. (SEE NOTES) ° ° a ° FROM BOTTOM EDGE d z 4.21 E9 4.21 E9 o ,D Cn E c Z o - MONITOR ACCESSORY p c U ° o 0 OF VALANCE WALL w s o o o o x BRACKET SYSTEM �� c r p ° v CLIPS TO , WITH w N 2"-6>, ACCESSORY LEVELING ° �~ •S ° ° SYSTEM CONTROL ° Q (D ° o �- IF n O NO o co II (III III F III -_ III II ADJACENT ] - ° ° ° LL_ o mm �� WALL OR °L."� : ° ° o i Q m® I I III III III [gin ® II p ° ° ° C U _ ONLY LOW I LII III III III III II ) INSTALLATION9 I N o ° °o C a� IL - - - - -Il - - - - - - �L - - - - - - �I- - - - - - - -jL - - - - - - - WALL MOUNTING SUPPORTS 0 ° � ° � a *SECURE TO EXISTING STUDS OR 3/4" PLYWOOD BACKING • 3 c °J 3 - U 10'-5" V_9" 1'-9" 2'-1 " w ® o ° 3 0 REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS ° o w ° In c w v ° o ° VI N .0 U WOUNTED TO \ a ° �� � o a a DMB INSTALLER NOTE: BACK OF DISPLAY HORIZONTAL DIMENSIONS KEY NOTES ❑ THIS SLIP SHEET IS PROVIDED FOR ELECTRICAL � H C, 3 ° °n 2" PREFERRED MONITOR L=EED ROUGH-IN PREPARATION AND GENERAL DIGITAL n BOTTOM OF DMB FLUSH REFERENCED FROM RIGHT MENU BOARD MOUNTING GUIDELINES. EVALUATE TO BOTTOM OF VALANCE-MINIMUM FRONT OF VALANCE WALL EXISTING VALANCE WALL STRUCTURE AND BACKING � CO } o Qp INTERRUPT MATERIALS TO ENSURE ADEQUATE SUPPORT OF > a m w - _ Ln SEE KEY NOTES 0 0 DMB INSTALLATION & ELECTRICAL REQUIREMENTS PANEL WALL EQUIPMENT. m o O Q Q C'jO w (APPLICATION: MRP OR EXISTING STORES) ALL HEADER AND WALL PENETRATIONS FOR Cl D w � Q ON CONDUITS OR OTHER ELECTRICAL ROUTING MUST a I- Ln U w w a- 0 I 2"-6" STANDARD BE SEALED TIGHT. (6"-10" IF NO ADJACENT WALL OR ONLY LOW WALL) w Q w � Ln U ❑ MEDIA PLAYER FOR MENUBOARD TO BE MOUNTED V~) CD ? 2" MIN CLEARANCE 18'-3" MIN 3 BEHIND UNIT ci E 1 N s LO MEDIA ° N MENU MENU MENU MENU MENU 4.21 E2 PLAYER DIGITAL MENU BOARD (DMB) INSTAL.LATION NOTES: z • DMB SUPPORT EQUIPMENT INCLUDES: z - NETWORK MANAGEMENT DEVICE (NMD) CENTER ISLAND WALL I ❑ - 24 PORT ENHANCED WAYPORT SWITCH (EWS) INTERRUPT PANEL WALL w THIS EQUIPMENT IS MOUNTED IN TECHNOLOGY CLOSET ___ _ FOR NEW BUILDINGS, OR IN MANAGER'S OFFICE FOR z_ 6 EXISTING BUILDINGS. 0 J BOTTOM of VALANCE DMB INSTALLERS TO ROUTE CONTROL WIRES w FROM NMD/EWS ABOVE CEILING TO MENU BOARD HORIZONTAL DIMENSIONS VALANCE WALL. WIRES TO EXIT WALL BEHIND z t-- PASS N j PAss THRU- REFERENCED FROM LEFT EITHER FURTHEST LEFT OR FURTHEST RIGHT DMB z - WHERE APPLICAP'LE i OVERSHELF- PICK UP POINT OF SALE (TYPICALLY s)_ SECTION AS CONDUCIVE TO SITE CONDITIONS. O ouTUNr_ of EACH DMB SECTION REQUIRES A DEDICATED z o FRONT COUNTER MEDIA PLAYER MOUNTED BEHIND THE DMB UNIT. a CO � HLZ CABINET BACK OF VALANCE WALL o_ w oo Issues Rev Date B Drawing a MENU BOARD LAYOUT Project y g LL m w LEVERAGE SITE READINESS CHECKLIST DIGITAL MENU BOARD - 4/28/2015 SPB PRIOR TO AT&T INSTALLATION O z o ~ co TYPICAL INSTALLATION TEMPLATE w z Z Q cn `° z LO 2111 McDonalds Drive Project Number CO LD w Oak Brook, IL 60523 Description SLIP SHEET- LANDSCAPE 2+1+1 +1 FUTURE READY W O X C) o X JLi All drawings and written material appearing herein consitute original and unpublished work of McDonald's Corporation I- N W W U W �- and may not be duplicated,used or disclosed without the written consent at McDonald's Corporation. H (n O 031 .1745.00.0 0 z Lj w E392 Ln ROUGH IN SHEDULES CHANNEL FOR DATA CONDUIT FOR CABLES POWER m POS & COD ISOLATED GROUND/DEDICATED CIRCUIT KEY NOTES 4 SOLID #12 AWG DIPPER CONDUCTORS THIS IS THE ONLY POINT WHERE THE ISOLATED 8 1 EQUIPMENT GROUNDING CONDUCTOR SHALL BE 1100 °00°0 0°0°0 • SHOWS CONNECTION/BONDING POINT ONLY. 001 100 000 CONNECTED TO THE BUILDING'S GROUNDING SYSTEM. ADA 48" MAX PAGER IS EXISTING 2 SEE BUILDING GROUNDING DETAIL THIS SHEET. APPROX. 3" ABOVE WHEN 800A SERVICE ENTRANCE 3 PANEL CP 9 ❑ 1-1/2" METAL CONDUIT: 4-#1 CU + 1-#6 CU BRACKET IS FULL AND TOP Main (TYPICALLY MDP) COMPUTER ONLY 3 EQUIP GND + 1-#4 CU ISOLATED GND. Distribution PAGER IS ROTATED 90 DEG Panel A B C BU9 A B G BLU 10 a ALL ISOLATED GROUND/ DEDICATED CIRCUIT RECEPTACLE COVER PLATES SHALL BE ORANGE NOTES: z �OA,.-2P BLS GRN WWT STRIP HUBBELL PJ7CO (SINGLE), PJ8Co (ONE DUPLEX) OR m m O BLU GRNPJ82CO (TWO DUPLEX) MARKED "COMPUTER ONLY". 1. SINGLE SIDED KIOSK NEw m METAL JUNCTIO 11 USES 8A AT 120V. PANEL AP-3 12 wHT BOX METAL CONDUIT SHALL CONTAIN ONLY P.O.S. CIRCUIT -I] m 4 AWG GRN LW STRIP 5 PROVIDE 20A MOCP GRN 12 CONDUCTORS (DEDICATED CIRCUIT). ONLY USE RIGID WITHIN CP PANEL. cu E PROVIDE 225A 3-POLE C/B FOR PANEL W NON-METALLIC CONDUIT BELOW GRADE WHEN c N rJ REQUIRED BY LOCAL CODE. ih EU EU AP-3. MATCH EXISTING AIC RATINGS. � 13 2. DOUBLE SIDED KIOSK N PROVIDE 225A FEEDER (4)#4/0, (1)#4 GRN YLW a EQUIPMENT GROUNDING BONDING CONDUCTOR USES 9A ID 120IOV. c Eu UD GND, (1)#4 ISO GND IN 2-1/2"C TO NEW 6 (TYPICAL) PROVIDE 20A MOCP o m � PANEL LOCATION N a ISOLATED GROUND BUS, ELECTRICALLY INSULATED WITHIN CP PANEL. T� FROM PANEL ENCLOSURE USED TO TERMINATE ONLY � B ISOLATED EQUIPMENT GROUNDING CONDUCTORS. ALL CONDUCTORS SHALL BE SOLID COPPER AND 3. POWER FROM ABOVE 1 � TERMINATED To THEIR APPROPRIATE TERMINAL SCREWS (WITH STANDARD o BY WRAPPING THE CONDUCTOR COMPLETELY AROUND CEILING HEIGHT) IF THE SCREW BARREL AND TIGHTENING THE SCREW PER CEILING IS ABOVE ^ NEW AP-3, 225A, 2 MANUFACTURER'S TORQUE SPECIFICATIONS. ISOLATED GROUND RECEPTACLE 10'-6" CONTACT USRD � _ 42 SPACE PANEL NOTES HUBBELL-IG4700,IG4710,IG5262 OR IG5261. SEE PROJECT MANAGER. ROUGH IN SCHEDULE FOR THE APPROPRIATE 25.2in °0110 °0°00 °01°00 000 °°° °°° 1NOFTLES.O.S. EQUIPMENT (COM PUTERS,PRINTERS,MONITORS RECEPTACLE TO USE.10 3.7in ISOLATED GREEN GROUND SCREW. KVS, MODEM, HUB & COD) SHALL BE POWERED FROM 6. EC SHALL VERIFY THAT SUBPANEL CP DOES NOT CONTAIN ❑ Ld THE COMPUTER PANEL. ANY ILLEGAL NEUTRAL TO GROUND BONDS. I- 7. PANEL CP SHALL ONLY BE USED TO POWER SENSITIVE 11 ISOLATED EQUIPMENT GROUNDING CONDUCTOR (GRN 3.9in o ALL OTHER COMPUTER/DIGITAL EQUIPMENT SHALL BE w/YLW STRIP) - POWERED FROM PHASE "A" IN THE COMPUTER PANEL. ELECTRONIC EQUIPMENT, AS OUTLINED IN NOTE #1. IT 13.3in SHALL NOT BE USED TO POWER ANY OTHER LOADS. 12 NEUTRAL CONDUCTOR TERMINATED ON SILVER SCREW. 21.6in -4 w 2. ISOLATED GROUND INSTALLATION SHALL COMPLY WITH THE PHASE CONDUCTOR TERMINATED ON BRASS SCREW REQUIREMENTS OF NEC SECTION 250 8. IT IS A SAFETY HAZARD AND AN NEC VIOLATION FOR THE 13 FRONT E L EUAT I 0 N SIDE ELEVATION 2POS SYSTEM TO HAVE ITS OWN INDEPENDENT GROUNDING 3. EACH 20 AMP CIRCUIT SHALL HAVE IT'S OWN ISOLATED ROD. IF AN INDEPENDENT GROUND ROD IS FOUND FOR EQUIPMENT GROUNDING CONDUCTOR. BUILDING GROUNDING SYSTEM. i`r UR fig_, THE POS SYSTEM, IT SHALL BE BONDED TO THE - K10SK ELECTRICAL SINGLE LINE DIAGRAM 4. ENTIRE GROUNDING SYSTEM SHALL COMPLY WITH NEC ARTICLE 250 AND MCDONALD's BUILDING GROUNDING .s: :;{; , , r�S DETAIL. N.T.S. N.T.S. LU r., 5. EC SHALL VERIFY CORRECT POLARITY AT RECEPTACLE. t': °''" ' 'J PANEBOARD: AP--.3 (NEW) BUS AMPS: 225A EQUIPMENT GROUND BUS i,.al ` a '< °N NOTE MAIN SIZE/TYPE: MLO ISOLATED GROUND BUS o a-,� VOLTS/PHASE: 208Y/12OV, 3PH, 4WmIL o DETAILS SHOWN ARE TYPICAL SERVES: .,. ....... ; z Z CONFIGURATION ONLY. SITE SPECIFICS LOCATION: BOH MOUNTING: RECESSED r}. Uj tea° MIGHT CAUSE DEVIATIONS. CKT DESCRIPTION VA PHASE IWIREJ BKR 1PIP1 BKR WIRE VA PHASE DESCRIPTION CKT ` w Z Qx NO. A B I C I NO. JAMPI AMP NO. 1 A I B 1C N0. G 1 TOMATO COOLER 696 12 20 1 2 .20 12 1,643 BUN TOASTER 2 LU °Z `' - Z 0(D IG 3 KVS MONITORS 1,260 12 20 1 1,643 4 G 5 Warewasher - Undercounter 1,440 12 20 1 2 30 10 2,496 TOASTER TABLE 6 Z Q o Lu G 7 CYT Dessert Blender 144 12 20 1 2,496 8 ! IG 9 GRILL TIMER 180 12 20 1 2 30 10 2,496 TOASTER TABLE 10 m 0 g G 11 CYT Dessert Chill Unit 240 12 20 1 2,49612 m U a G 13 CREAM DISPENSER 120 12 20 1 1 20 12 552 COMB FREEEZER/COOLER 14 G o H o muco __ IG 5 ORB MONITOR/PRINTERS 612 12 20 1 2 20 12 1,570 EGG STATION 16 Q _ z J .. -- -- : y 17 SPARE 20 1 _ 1,570 18 °w U 0 ►, DUAL POINT PICK-UP J ,y 19 SPARE 20 1 1 20 1 12 1,200 DCO MHE CYT EQUIPMENT 20 STATION DVERSHELF L NEW ELECTRICAL -� ;X ' ELECTRICAL A I ' I I IG 21 ORDER KIOSK 1,080 12 20 1 1 20 12 180 TABLE LOCATOR 22 IG RECEPTACLE FOR ORB. 23 SPACE 1 1 SPACE 24 ° kITCHEN COORDINATION NOTE: a RECEPTACLES FOR h11PJl �d VERIFY LOCATION IN ° � � s " -o DRB AND scarJNER - - - 701.13 E3 cElurdc, 25 SPACE 1 1 SPACE 26 o i ° ° ° N NEW ELECTRICAL - - -- --- }� I ! I IG 27 DIGITAL BULLITEN BOARD 892 12 20 1 1 20 12 180 POS VIDEO MONITOR 28 IG NEW CIRCUITRY IS PROVIDED FOR ALL KITCHEN EQUIPMENT a o ° a ° ° o RECEPTACLE FOR oee. - - - - - --- - -- �„ 29 SPACE 1 1 SPACE 311 DESIGNATED AS NEW ON THE KITCHEN EQUIPMENT DRAWINGS. EC CAN � ° N VERIFY LOCATIOM IN / p 4°' 14 3'-0" 2'-7" o `- Q ° U) ( o ° CEILING. f Y-0" Mlyd. 2'-Ir MIN. 2'-B" MIN. 31 SPACE 1 1 _ SPACE 32 RE-USE EXISTING CIRCUITRY AND CONTROL WHERE POSSIBLE. N r�r� Q � ° �y CDUl U1 Cc U1 0Ui (0ci 4'-0' STD. 3'-D" ETD. Y-O" STD. 33 SPACE 1 1 SPACE 34 CONFIRM LIKE SIZED BREAKERS, WIRES AND CONDUITS. o ° � �° ° a o 00 o ao oa bo 35 SPACE 1 1 SPACE 36 NOT ALL EQUIPMENT LABELED AS NEW WILL HAVE EXISTING CIRCUITRY. ° ° 3 °� f v� a a Q o 4 0 0 0 5'-0" MAX. 3'-D" 3'-4" MAX. S-4' MAX. '-2' 0 Q N Q I m m m m m m rn m m m _3„ (AOA HOLO) 37 CLAMSHELL GRILL 2,640 10 30 3 1 SPACE 38 o ' O O W 113 cN w L.4 O�O - -� - -� OVERALL COUNTER LENGTH VARIES 39 2,640 SPACE OVERALL COUNTER LENGTH VARIES 5 CHART BELOW) , ♦♦�� O �� O � O _ sEE HA.T Loan 41 2,640 SPACE 402 0 U) U ° �'�a c 0•- O c MORT COUNTER ELECTRIC�►1. ROUGH-INS CONT CQUNTER W H DUAL POINT INCORPO� SUBTOTAL 3,600 6,664 4,320 5,891 6,069 6,562 SUBTOTAL Q � ° 3 ° ° �s ° a .20 xT5 xrs TOTAL PHASE A - VA 9,491 LOAD CONN. VA DF LOAD CONN. VA DIF y _ ° AMPS 79 COOLING 1.00 REFRIGERATION 1.00 � ° a v ° -0 0.:?, �, E '-' c SAMPLE ELECTRICAL SCHEDULE TOTAL PHASE B - VA 12,733 HEATING 0 SIGN DISPLAY 1.25 ° o ° c ° TAG # QTY DESCRIP110N VOLT/PH FLA BRK SIZE GOND/WIRE PNL/GCT RECEP TYPE HGT AFF REQUIREMENTS & REMARKS AMPS 106 LIGHTING 1.25 KITCHEN 27,522 0.65 �'"� V) v � o° ° ° 2 U 215.00E1 4 POS PC HARDWARE - FRONT COUPJTER 120/1 3.0 Ek 20A 1/2"C-2#1210 CP:17 IG47DD 2'-D" EC r0 RUN 3/4" COND IN WALL FOR FLUSH MTD SPCL. RECEP TOTAL PHASE C - VA 10,882 RECEPTACLES 5,584 .0 EXISTING 1,00 CIO - _j ° o p ISOLATED FOP, KEYSTATIONS (1,1DNITOR,CPU & CASH DRAWERS) O 00 _c 215,00E6, 1 POS PC HAI DUW,\RE - FRONT COONTER DATA CABLE - - - - 4x4x4 PB 1'-E" EY,TEND 2 1/2" CONDUIT UNDER SLAB TO 215.DOE7 FOR POS DATA AMPS 91 MOTORS 1.00 LARGE MOTOR 1.25 TOTAL DEMAND c � � o:� ° c c o CABLES TOTAL PNLBD - VA 33,106 SUPP HEAT 1.00 SHOW WINDOW 1.25 23,473 VA 215.04F1 1 ORB r.^orJITOR (MINI) 120/1 1.5 EA. 20A 1/2"c-2#1210 cP:17 c47oa 1'-s" - AMPS 92 MISC EQUIP 1.00 LTG TRACK 1.00 65 A U, o ° ° .0 ISOLATED 21s.U5E1 1 OPf3 MONITOR 12C/1 1.5 EA. 20A 1/2"C-2#121G CP:4 IC47DD FLUSH ON - G = GFCI CIRCUIT PROTECTION ° Q U) E ISOLATED acIG = ISOLATED GROUND, PHASE "B" ° ° 0 7(, a o 219.DDE3 4 P05 - RECEIPT PRINTEIR/CASHLESS 120/1 D.7 20A 1/2"C-2#12IG CP:4,5 SEE RYKS IG47DD 2'-0" FOR RECEIPT LOCATED IN FRONT CCUr1TER POWER FROM CP:4 IN C) c •N o o ISOLATED PRESENTER'S BOOTH CP:4 ° _ c a 701.13E3 1 DCO - GENERAL PURPOSE 120/1 1.5 20A 1/2"C-2#12 AP-2:5 5-20R 1'-g" - O � = c 0 z L� 0 0 ' 0 0 0 0 0 DUAL POINT CONVERSION NOTES: w Of e- N 1 co 1) O O 0 A N U U 1 . ADDITIONAL POWER FOR CREW MINI-ORB AND SCANNER LOCATED UNDER COUNTER. SEE 216.04/DETAIL 1 (ELECTRICAL ROUGH-INS) w � o� o Q)Z ° 2. ADDITIONAL POWER FOR CUSTOMER ORB MONITOR INSTALLED AT FACE OF SOFFIT. SEE 216.05/DETAIL 1 (ELECTRICAL ROUGH-INS) � Q 3 � ° 3_ SEQUENCE MENU BOARDS PER DUAL POINT STANDARDS 4_ NON-SEEQ INSTALL - PICK-UP SHELF MATERIALS TO MATCH CBB CELL WITH 1 OF 12 APPROVED LAMINATE SELECTIONS_ KES TO ORDER FROM DECOR Li o �Ln COMPANY_ (VERIFIED AT TIME OF SURVEY) m o O m J L o w ,t 5. SEEQ INSTALL - PICK-UP SHELF MATERIALS TO MATCH DECOR FRONT COUNTER CORIAN SPECIFICATION, GC' TO FABRICATE AND IPISTALL TO Z w N 0Q U" N 00 SPECIFICATIONS. (LINEN OR RICE PAPER) a I . � = w � w � a N U 6. SIGNAGE PACKAGE PROVIDED BY KES AND INSTALLED BY G.C. o Q � cn o 0 7. ADA PLATFORM SOLUTION DOES NOT MEET ADA REQUIREMENTS IN CA, IL OR FL. cf) :E o z 8. .3'-0" MINIIv1UM ADA SPACE REQUIRED BETWEEN END OF PICK-UP SHELF AND FIRST KEYSTATION 9. ORDER READY BOARD TO BE CENTERED ON PICK-UP SHELF OR ADA PLATFORM. m THIS SLIP SHEET IS PROVIDED FOR REFERENCE ONLY. ADDITIONAL MODIFICATIONS TO THE HLZ, CENTER ISLAND AND POS SYSTEM WILL BE REQUIRED TO COMPLETE THE DUAL POINT SERVICE INSTALLATION. PLEASE VERIFY LAYOUT, NUMBER OF KEYSTATIONS AND DIMENSIONS WITH KES AND REGIONAL DUAL POINT z LEAD PRIOR TO FABRICATIONJ OR INSTALLATION. 0 DUAL POINT FRONT COUNTER PLANS =M- KT,& w Z H N O (n Z W Z _ Li D ° J0 F (n O -J Li W 0_ C)f c O w 0 o LL m L a z w o O - o m z WCD _ 00 Qw z C) z (-o l= LJ J (n LJ N W J C) w � o U) 0 031 .1745.00.0 0 z n E4e 1 _ 0 ONE-LINE & SCHEDULES m z 0 0 cn w 0 w Q o w pF_N Er j ` c�t�� ,jar•f._..•�.,<a� j tiff E e A� °..�__"""".• \'��Flyy � � Qwa vN no REVERSE �P OSMOSIS z -uz SYSTEM ' ora°- . .. w <0� Ji wzit Z <wo �... W \ DUNNAGE MDP AP-2 I \ LZ uza RACK AP-1 BULK HOT o L - - -� RO - � - WATER `� z W 14" X 36" FREEZER ELECTRIC TANK 4-TIER w PANELSEl ;`.' 26"x52" II w S ii TIER ili I�NNAGE D i�G' - 18„ X 46" m �" W M RSA ll ACK 4-TIER I: ~ moo m w , ❑ �74 Q azo 26"x52" x w UOE) a) u TIER n13 II II � d' d � Q v�i�d u oO BMX i RESTROOMS o II II a d- ft�w i t o v ° ° m X i ♦ I 0 ° p ° a ° a' o 0 X n O_O-U N 00 0 u 26"X52" II ° `o TIER i - CLOSET o ° ° COOLER 11 I - - ° ° 3 o 0 o 1)7e M 0 P --------- ----- o _ a a - o U O `- -/ I �� SINK ° Q) 6 ° Q) Q) 4-TIER pp - ° 0 '' o ° � o• RESTROOMS. KETCHUP =_ c N 3 DISP. U U ° O p ° 0 O o ° CONDIMENTS -' � o _ ® STRAWS ; -- • p " ° _______ _ . __,__�� 0- ,0- p p O 9 -1� ;; p a 4'-9 4 8,_6141„ 8,_42„ 2,_6, NAPKINS I------- s ' L _ u In // CONDIMENTS ------------- ''� ` - ( - ° ° 4 ° HAND CART KETCHUP PQr, - < U �� ° N MOP 0, Q o SINK I � 0.J. 1 P ,a , 7) a ° - SCULLERY SINK SINK \ n i -------------------' ! c a � E CREW = OFFICE REAMER a ° ° ° ° a, o ao ROOM I SAFE ^I IDS POS ,,, N o ELECTRIC "� a IDS \ I ,,�, � a� �, U PANEL - LIDS °' ° C C o E"",�. o o '- o 0 LP I N I O'' '01 ® 3 ° O BR _ 0 ° =� OFFEE C° L=-� CONDIMENT21 ° o COFFEE I CART �. �. a- ° cn — — — , I III I (0', 1`01 ;;0 ,0. Li WTR27 S C I ° EXISTING BISCUIT I I III o COFFEE I `O OVEN BUN TE­AI -- I � ----------• •---------• •---------• � ANSUL � I PULL STORAGE ICE BREW N ( WTR2a7 POS i Q - m l 1 BULK C AP,T \ I ---- ---- n m o 0 o w Ln OIL r 11MAAAHINE HAND I SMOOTHIE TRAY I cV N 0 `� N CART UNIVERSAL OEP SINK Q-ING CART L--� -n i Q vim_ v L w o HD PREP TABLE OVEN --- O oo w cn c� o EP TOASTER -- - I n i ;' \ N o m BULK MUFFIN z w � POS Q 0 u OIL - > BUN HD TRAY o TOASTER o o BOX UHC 00 UHC CART Ln _ IE REACH-IN I I I L i i i r -I IJNDERCOUNTER PRINTER I _ z FREEZER k CASTER = GREASE STEAMER TABLE \ L,% L- HM CART _ BUN DISPOSAL = N CANDY HAND SODA/ICE SODA/ICE Y r r ARCH I COMBO DISP DISP o STORAGE R CLAM GSF30 LANDING - SINK - i FRY `y MACHINE " DISP SHELF CUP/LID/ HAND i oo SPOONS I i -- — __- - - - _ Q Q :WTR27 WTR27 BLENDER -FRY STTION LLJ ° ° ° --------- , w FRZ'RI ° ° '° -o .. - °� Q i.IZ N z UJ NANKIN z I- D °o 01 01DISP Q 10 � w o w o .o = o m L�j Q - o o co AS-BUILT CONDITIONS IN THIS DRAWING SET ARE DRAWN AND O Z W _ CO z Q w VERIFIED BY OTHERS. FRANKE FOODSERVICE SYSTEMS, INC. IS NOT RESPONSIBLE FOR ANY ERRORS OR DISCREPANCIES AS A RESULT z 1 z o t W OF AS-BUILT DRAWINGS. USAGE OF THIS DRAWING RELEASES T u a � FRANKE FOODSERVICE SYSTEMS, INC FROM ANY LIABILITY RELATED � f \ I C I I D DEMO S H E E T � U Li w O x a o x w l N W w o w TO EXISTING CONDITIONS AND AS-BUILT DRAWINGS ERRORS OR ~ o cn o DISCREPANCIES. KEI AND GENERAL CONTRACTOR TO FIELD VERIFY JD1/4" = 1'-0" 031 .1745.00.0 EXISTING CONDITIONS BEFORE BEGINNING ANY WORK. 0 z EXISTING EQUIPMENT DEMO EQUIPMENT W w U) KES CONCERNS TO MOD DRAWING REVIEWER : m ® CYT CONVERSION NOTES RELOCATED COMBO MACHINE OVER HAPS 99 4-TIER TOASTER TABLE CREAMER 0 ADD WARE WASHER AND RECONFIGURE SCULLERY THE CBB CABINET BY 4- AREA AS SHOWN ON THESE PLANS , e AS LEWAYS ARE NARROW IN GRILL SHELF • ADD TOM ATO COOLER AS SHOWN ON THESE P LAN S� STORE WITH STORAGE 0 RECONFIGURE PREP — LINE AS SHOWN TO CREATE THE PLACEMENT EN T OF NEW AND RELOCATED CYT AREA. EQUIPMENT z • POS INSTALLER TO DETERMINE FINAL LOCATION FOR GRILL STATION KVS MONITORS W 0 0 RECONFIGURE CENTER ISLAND AREA AS SHOWN ON THESE PLANS. O RELOCATE BLENDED ICE AND SPEC COFFEE NEXT TO THE FRY HOLDER AND RECONFIGURE THE AREA AS SHOWN ON THESE PLANS. 2 REMOVED EQUIPMENT _ 3 GENERAL SCOPE OF WORK W K1 . 0 1/4" = V-D" K1 . 0 NTS Q 0 Li MENUBOARD VALANCE WALL , DIGITAL MENUBOARDS , AND MODULAR ` °{ �� FRONT COUNTER DESIGNED AND COORDINATED BY ARCHITECT. cc ��'' �'�. '�moi.€_ •�. f+ll fi LL 00 w� o _ j Z =-z z p p wQp H o:G Li LJ0 Z_ ago AP 2 \ \ DUNNAGE 1111DP AP-1 \ \ \ 0(D< ui Z pC7a RACK I BU�K HOT w pw 14" X 36" �� WATER REVERSE RO \\ Q o ELECTRIC 4-TIER FREEZER PANELS OSMOSIS TANK DUNNAGE w m IEl I SYSTEM MOP - RACK = _ - II II — SINK m o \ - - - —I m U �Nm N II � (Y \ \� 11 \ \ ` w LOQ Ld \ \ L U1 n IIzo I X I IC 0 C a U io a a ii ii oO BOX RESTROOMS IN c ° ° a Q ia II II ° I II II 00 c O I Li.l ° o I I I I X H I �x� I `o o � � ° � c .` _ y a o O p a o O i O o 0 L O COOLER CL_OSET o E F c � c o ° O co MOP --------- - r O Q - rn SINK ; ocn / 0 _ a N 26" X 52" 4-TIER E a --------- ° c RESTROOf\vS -------- •�' � I °KETCHUP ° ° ° t ---- ° o °°O I CONDIMENTS F- STRAWS .-- ---0:--- c o ° o o � ° I NAPKINS ° CART I ® CONDIME ITS .� O O 7 O J _ — KETCHU" (IKD HAND -------- SINK DISHWASHER MONITOR J. •• N DISP. , o o ° cn --------------- POS SCULLERY SINK PRINTER LENDER CUP/LID ' - wCREW — HOLDER ------ o ° �UP/LID/ CART r SAFE PRINTER -II I a I co Q OFFICE SPOONS l al w I I 0 ELECTRIC ROOM REAMER a PANEL _xxx BBR RCU IDS EOTF i= N Q �,�.. ° ° p ° .O O LP IDS DESSERT POS 'i o w `•, %' o t,.�® L o 3 0 0.0 0 0 \ \ - - OFFEE BAG NAPKIN�__� o - o1 0 i i < � ° u ° ° ° ° ° °COFFEE CART a I Q ° a — - - COMBO a N 'Or ',0: ` `,Q, a a) o O O EXISTING BISCUIT WTR27 _ _ o MACHINE s a 3 ° - - 0 2 P O S - - -------- -- CANDY ANSUL OVEN REACH-IN CARP HAND 4'-5�" PULL '� TOMIATO ICE TEA` SINK i I = `� ? < `° o ° Ln BULK GREASE 1 = - I d H M E l a l c� o I m o o ' J D o W ,Ln OIL DISPOSALi ' E9DLEBUN MACHINE BREW _� -- RAY MONITOR i i = w __-_-, Z LL w "' o V) N o 0 LT UNIVERSAL Q-ING PCRC p , MONITOR -- a I Q c Q N = w w a N N OEPSTORAGE TOASTER PRINTER OEP OVEN OAS , " i "� o Q ® " o > < o MUFFIN PRINTER :O Q. Q, :0 o Q � o CD o BULK UC ,,0 0- ( OIL TOASTER z z + B N ri HD CART n -N o CART � o aUHC 00 u l B - UHC o o N 3- 9/2" r' IPIE w ¢ i I rn REACH-IN i EGG - BUN HD PREP TABLE HLZ FREEZER PRINTER COOKER/ TOASTER HM CART _ -MONIT R-- TABLE UNDERCOUNTER � o N ,-_,\ SODA/ICE SODA/ICE BUN R CLAM rCLAM XN ST'iE-AMER ARCH LANDING -I -I I BLE`\ ED \\ DISP DISP ° :!s STORAGE SF 0 ,- FRY "-) N I ICE�I - o 7EE� " DISP SHELF I I � HAND � _ --�------------ ---------• � HAND n SPEC SINK I �. ---- SICK WTR27 _ o TATION COFFEE "' w w WTR27 FRY S -- r WALL TOO-�DING \ _iVTR27� ! LnL >EEF FIR � � — I — fl— Q N O ~ Z CD Q Z Li COOLER/ 3'-1 NAPKIN z o w FREEZER DISP O w o •o LL F= o m w w o Lo O o N 00 LIJwJ co Q AS-BUILT CONDITIONS IN THIS DRAWING SET ARE DRAWN AND Z v z o cr w Ln VERIFIED BY OTHERS. FRANKE FOODSERVICE SYSTEMS, INC. IS NOT � r- RESPONSIBLE FOR ANY ERRORS OR DISCREPANCIES AS A RESULT w — v :5 a T OF AS-BUILT DRAWINGS. USAGE OF THUS DRAWING RELEASES KITCHEN SHEET W o w N0 FRANKE FOODSERVICE SYSTEMS, INC FROM ANY LIABILITY RELATED TO EXISTING CONDITIONS AND AS-BUILT DRAWINGS ERRORS OR 031 .1745.00.0 DISCREPANCIES. KEI AND GENERAL CONTRACTOR TO FIELD VERIFY K 1/4" = 1'-0" o EXISTING CONDITIONS BEFORE BEGINNING ANY WORK. K 1 0 EXISTING EQUIPMENT DEMO EQUIPMENT NEW EQUIPMENT RELOCATED EQUIPMENT = OPTIONAL/FUTURE EQUIPMENT w �,,J w N KITCHEN LAYOUT m z 0 m 0 w 0 w Q 0 w CE C c"} '.7 Sat ..,.., w,.. LL p� 00 Cj a�so ` y IsU n H-o L Z d Fwz ._...,..- .. 0 = z �C)o LLj(D Z K Z <EEo U)wx Z z 0°Q y uj U Z g'. W Z W \ \ I MDP AP-2 \ \ .' � m o \ AP-1 L - - -� � - - S IL - 800.12 m U afmF 'DN 800.20 801.38 0 r o 801.,42 900.98 ` = m l i 00 800.22 800.22 1 - ` rN L 8 01.3 8II I1 C� o i i 801.38 i i 801.38 0 0 o - 0 0 � � C. t I 801.38 O ( ° Baa > 0oo - - � N a ° 2 ° o ix� I o 3 � . o� � O n - N Q II II Us ° °'- 0_ 0 0 ° 800.98 ii 801.38 0 0 D C it �1 r o c 0 - - - c _ O rJ C� ; '---------- 00 n N ° � O _ ° ° O O C x O O C ° C C :__-__-- ®IS C (� _c U N U i cn •� ° - -° U - 4 O ❑ � � 800.59 90x.60 5------- N .Q - E -,_ 800.95 ------ ------ ° ��- = 800.86 900.63 900.39 ® " o y 152.06 - 800.22 ,. N o ° 21 5.04 •• ;C! ; �j Di C °_ °°Q o I 800.99 - 0 i' O / 2 207.30 3 ° 23.57 - - 219.00 ° ° � ° • 207.31 �� I 900.51 �------ -----------------------• ! o ® -° =� N � U � o 207.32 2.13 n ° V) ° ° ° 129.13 I ° 1 3.00 ° - 900.57 I 11 1 y o� � ° I 2.15 I i C` a LP 900.57 ! I 900.51 80137 (�xx OLO 6 4 2.13 \ - --q-77-1800.53 ° 801.37 r--� 3.00 - Q } o A - \� 800.22 -- iii 900.51 co) O n O• m o o Q j o w 900.82 800.84 - N - - 800.23 800.27 2.13 O ' O' ' z I_ Li o c 0 0 0 177.06 QO• 1 o N 900.92 3.00 n = w w a g 0-6. 1 N 901.38 2.14 -------- --------- ------ - � Q o OO i i - ; 2 6 215.04 Iii •---------• •---------• •---------• � , o � 0 2.2 A2 2 - n 44.74 i 7 K2.2 800.95 - r- 1 --------- � 801.41 2 ' 1„ _034„2,-53/4„ 4 _2„ 6 -3„ cv 2.18 L--� 801.41 219.00 i I OO OO C n _ 1 m I N I iC', 800.93 C` C` 900.95 z + - 801.36 i i 216.05 Y 00 0 I 800.17 N I 216.06 ° ---, b e I 801.48 i i 11 216.04 801.48 -__ _-- 1 " I J 900.85 900.27 900.46 900.45 127.00 800.62 5 800.06 - - - - 800.03 801.06 800.58 1900.351900.95 98.04 900.44 122.26 219.00 801. L - -o - - - 1 _ 143.0012 45 04 900.33 700.09 K2.2 801.35 800.58 800.08 800.03 w -- r 800.16 v' 2.2 800.95 ne ,---------- Ln - - 0 Z N o H -- CD < - r 2 o o , F _1 _ =� r- z n 1 ( i 800 11 1 .14 0 � cn ° i I �9 A J ° 0 ° ° 0 0 ° \ I - - --------- - Q cn � I r� w c O w c 0 LL_ m � � o 800.538001 ~ z `` w o 0 19" 18" 7'-0" ol .531.49 800.50 3'-0,4 2'-3" 2'-3" O CD N � 800.83 800.02 W z Q C-) °� AS-BUILT CONDITIONS IN THIS DRAWING SET ARE DRAWN AND 800.95 215.04 800.89 800.82 800.08 z 0 w VERIFIED BY OTHERS. FRANKE FOODSERVICE SYSTEMS, INC. IS NOT 215.06 96.14 901.23 cn a � 97.12 901.20 - w RESPONSIBLE FOR ANY ERRORS OR DISCREPANCIES AS A RESULT /� w a - I FFRANKE OF FOODSERV UILT DRAWINGS. ASYSTEMS IOF THIS NC FROM ANVYI-NLIABIRELEASES RELATED 53.01 901'22 DKITCHEN EQAPI V IEI YJA PLAN � W �901.21TO EXISTING CONDITIONS AND AS-BUILT DRAWINGS ERRORS OR K 031'.1745.00.0 DISCREPANCIES. KEI AND GENERAL CONTRACTOR TO FIELD VERIFY /4" = 1'-0" o EXISTING CONDITIONS BEFORE BEGINNING ANY WORK. z K 2 .0 n l �EXISTING EQUIPMENT NEW EQUIPMENT RELOCATED EQUIPMENT OPTIONAL/FUTURE EQUIPMENT w �„J vm KITCHEN EQUIPMENT s =Optional Equipment VIF Verify in Field EQUIPMENT SCHEDULE PB -Pullbox VIF_Verify In Field E E C TR I C A L SCHEDULE GC ox = General Contractor E E*fisting EquipmentJB Junction R = Relocated E ument EC =Electrical BContractor EL__ i ITEM # OPT QTY DESCRIPTION MANUFACTURPR MODEL # UL # NSF # FURNISHED GENERAL REMARKS SPECIAL REMARKS ITEM # TAG # QTY DESCRIPTION VOLT/PHASE AMPS HP RECEPT TYPE BRKR SIZE COND / WIRE HGT AFF SPECIAL REMARKS 2.13 - 3 UNDERCOUNTER PRINTER BASKET FRANKE 18005338 - - FRANKE MOUNTS UNDER FRONT COUNTER - 23.57 023.57E1 1 CREAM DISPENSER - DOUBLE WIDE 120/1 1.0 - 5-20R 20A 1/2"C-2#12 2'_3" 2.14 - 1 BAG/NAPKIN STOCK CART INTERMETRO MCD-DP 1430B - 2 FRANKE - - 36" NEXT GEN 3-PLATEN CLAMSHELL GRILL - 2 0 - BY KES 3 24C 31 96.14 096.14E1 1 . 30A 1 IDEA SEE RMKS PLUGS IN RACEWAY RECEP WITH(1)L21-20P 2.15 - 1 CUP/LID SLEEVE STOCK CART INTERMETRO MCD-DP 1830CS - 2 FRANKE - - GAS/ELECTRIC 208_ / / # INTERLOCK& (1) 15-30P POWER PLUG EA GRILL 2.18 - 1 PULP CARRIER CART FRANKE 18007263 - 2 FRANKE 97.12 097.12E1 1 COMBINATION FREEZER/COOLER 120/1 4.6 1/3 SEE RMKS 20A 1/2"C-2#1 3.00 - 3 CASH DRAWER SHELF FRANKE 18003739 - 2 FRANKE LOCATED UNDER FRONT COUNTER - - 2 SEE RMKS UNIT PLUGS INTO RACEWAY RECEPTACLE 23.57 - 1 CREAM DISPENSER - DOUBLE WIDE SURE SHOT AC230-PC-29 - - OWNER - - 122.26 122.26E1 1 50" TOASTER TABLE W/ POWER PIN & SLEEVE 208/1 24.0 - SEE RMKS PLUGS INTO OVERHEAD RECEPTACLE # 33006W(13) 44.74 - 1 ORDER ASSEMBLY STAND - 27" W/ 8 CUPS FRANKE FS01225 - 2 FRANKE - - (2)30A 1/2"C-2#10 5'-6" PROVIDED BY KES- HEIGHT TO BOTTOM OF --- RECEPTACLE 53.01 - 1 CYT CHEESE PAN HOLDERRANK 27802347 - 2 FRANKE - PLUGS INTO OVERHEAD RECEPTACLE #32006W/ BUTTER WHEEL 208/W 1 127.00 127.00E2 BUN TOASTER 1 15.8 - SEE RMKS 20A 1/2"C-2#12 5'-6" PROVIDED BY KES - HEIGHT TO BOTTOM OF - 96.14 - 1 36" NEXT GEN 3-PLATEN CLAMSHELL GRILL GAS/ELECTRIC GARLAND MWG3W E28898 4 FRANKE - - -._.___ RECEPTACLE 97.12 - 1 COMBINATION FREEZER/COOLER FRANKE K557782 - - FRANKE - _ 143.00 143.00E3 1 EGG STATION - MANUAL - P&S 208/1 15.1 - BY KES 20A 1/2"C-2#12 5'_6" KES TO PROVIDE OEP RECEPTACLE - HEIGHT TO z 98.04 X 1 EGG COOKER TABLE FRANKE 18001418 - 2 FRANKE - - 152.06 152.06E1 1 IWAREWASHER - UNDERCOUNTER 120/1 12.0 1 5-20R 20A 1/2"C-2#12 1'-6" BOTTOM OF RECEPTACLE 0 122.26 - 1 50" TOASTER TABLE W/ POWER FRANKE 18004721 - - FRANKE POWER OUTLETS FOR STEAMER AND BUN TOASTER - 177.06 177.06E1 1 REACH-IN TOMATO COOLER-SINGLE WIDE RH 120/1 5.8 1/3 5-20R 20A 1/2"C-2#12 7'-6" n 127.00 - 1 BUN TOASTER W/ BUTTER WHEEL ANTUNES VCT2000 - - FRANKE - - 207.31 207.31 E1 1 CYT DESSERT BLENDER 120/1 1.2 - 5-20P 20A 1/2"C-2#12 2'-8" - U 129.13 - 1 PRINTER/BUMP BAR HOLDER FRANKE 18007691 - - FRANKE - - 207.32 207.32E1 1 CYT DESSERT CHILL UNIT 120/1 2 - 5-20P 20A 1/2"C-2#12 2'-8" w 143.00 X 1 EGG STATION - MANUAL ANTU^NES MES-1200 E49407 4 FRANKE - - 215.04 215.04E1 3 POS - KVS MONITOR 120/1 ISOLATED 3.0 - IG4700 20A 1/2"C-2#121G @ CLG 1.5 EACH MONITOR 152.06 - 1 WAREWASHER - UNDERCOUNTER ECOLAB U-LT-1 - _ MANU- _ - FACTURER 215.04 215.04E2 4 POS - KVS MONITOR DATA CABLE - - - - - @ CLG CABLE FURNISHED AND INSTALLED BY POS SUPPLIER 177.06 - 1 REACH-IN TOMATO COOLER-SINGLE WIDE RH BEVERAGE AIR HR1-1S-T6 - 7 FRANKE USED AS CYT TOMATO COOLER ONLY - 215.04 215.04E5 1 POS - KVS MONITOR 120/1 ISOLATED 1.5 - IG4700 20A 1/2"C-2#121G 6'-1" FOR WALL MOUNTED CYT KVS MONITORS 207.30 - 1 CYT DESSERT FINISHING STATION FRANKE 20.110004698 - - FRANKE - - 215.06 215.06E1 1 CYT GRILL SEAR TIMER 12O/1 ISOLATED 1.5 - IG4700 20A 1 2"C-2 121G © CLG 207.31 - 1 CYT DESSERT BLENDER VITAMIX 056385 - - FRANKE - - / # - 207.32 - 1 CYT DESSERT CHILL UNIT SILVER KING SKPS3 - - FRANKE - _ 215.04 215.06E3 1 CYT GRILL SEAR TIMER DATA CABLE - - - - - © CLG CABLE FURNISHED AND INSTALLED BY POS 215.04 - 4 POS - KVS MONITOR BY OWNERBY OWNER OEM - OWNER - - 216.04 216.04E1 1 ORB MONITOR (MINI) & SCANNER 120/1 ISOLATED 1.5 EA - 5-15R IG4700 20A 1/2"C-2#121G 1'-6" SUPPLIER 215.06 - 1 CYT GRILL SEAR TIMER BY OWNER BY OWNER OEM - OWNER 216.05 216.05E1 1 ORB MONITOR 120/1 ISOLATED 1.5 EA - L5-15R IG4700 20A 1 2 C 2 121G FLUSH ON _ 216.04 - 1 ORB MONITOR (MINI) & SCANNER BY OWNER BY OWNER OEM - OWNER - - / / # CEILING 216.05 - 1 ORB MONITOR BY OWNER BY OWNER OEM - OWNER - - 219.00 219.00E1 2 POS - RECEIPT PRINTER 120/1 ISOLATED 0.7 - IG4700 20A 1/2"C-2#1 21C @ CLG - "ORDER HERE" & "PICK-UP HERE" SET WITH BR METAL 216.06 - 1 DPCS - - FRANKE - - 219.00 219.00E2 2 POS - RECEIPT PRINTER DATA CABLE - - - - © CLG CABLE FURNISHED AND INSTALLED BY POS SYSTEM HARDWARE TECHNOLOGY SUPPLIER 219.00 - 3 POS - RECEIPT PRINTER BY OWNER BY OWNER OEM - OWNER - - 219.00 219.00E5 1 POS - RECEIPT PRINTER 120/1 ISOLATED 0.7 - IG4700 20A 1/2"C-2#12IG 5'-6" 700.09 - 1 ECONOMY OEP BOX W/MOUNTING HARDWARE ACS v OEP-6 E71309 - FRANKE 6" W. x 24" D. - EXTEND 2" CONDUIT ABOVE CEILING. CABLE 701.08 - 2 Y FLOOR SINK - 1/2 GRATE GC - - - GC - _ 219.00 219.00E6 1 POS - RECEIPT PRINTER DATA CABLE - - 4x4x4 PB - - 5'-6" FURNISHED AND INSTALLED BY POS SYSTEM Li 701.34 - 1 DCO FOR HME TABLE LOCATOR SYSTEM GC - - - GC - - SUPPLIER ~ 700.09 700.09E1 1 ECONOMY OEP BOX W/MOUNTING HARDWARE - - - BY KES - - o 800.02 E 1 EXISTING FRYER EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - SEE RMKS CEILING MOUNTED 800.03 E 2 EXISTING SODA TOWER EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - 701.34 701.34E1 1 DCO - FOR HME CYT EQUIPMENT 120/1 10.0 - 5-20R 20A 1/2"C-2#12 SEE RMKS MOUNTS TO BACK OF HLZ CABINET - FOR TABLE 800.06 E 1 EXISTING UNIVERSAL HEATING CABINET TABLE EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - LOCATOR SYSTEM AND HME MONITOR 900.27 900.27E1 1 RELOCATED ECONOMY OEP BOX - - _ _ _ _ _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES > 800.08 E 2 EXISTING UTILITY/MECHANICAL CHASE EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN. VERIFY EXACT _ AS REQUIRED � LOCATION IN FIELD. 900.33 900.33E1 1 RELOCATED BUN TOASTER - - _ _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES 800.12 E 1 EXISTING WATER HEATER EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - - -..,�• 800.14 E 1 EXISTING FRY HOLDING STATION EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN AS REQUIRED � - 900.35 900.35E1 1 RELOCATED Q'ING OVEN - - _ _ _ _ _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES 800.16 E 1 EXISTING Q'ING OVEN EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - AS REQUIRED fNX ,_s, 800.17 E 1 EXISTING PIE MERCHANDISER EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - 900.45 900.45E1 1 RELOCATED FILET BUN STEAMER _ _ _ _ GC TO VERIFY AND REWORK ALL EXISTING UTILITES �? � 800.20 E 1 EXISTING REVERSE OSMOSIS SYSTEM EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - AS REQUIRED 900.46 900.46E1 2 RELOCATED/REDESIGNED KVS SYSTEM VERIFY VERIFY - VERIFY - �- 'Pill 900.46 800.22 E 4 EXISTING CART EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - -_- - - KVS/POS INSTALLER TO USE DED CIRCUIT/DATA 800.23 E 1 EXISTING TEA BREW STATION EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - CFJ, j t1� 9010.51 900.51 E1 4 RELOCATED/REDESIGNED POS SYSTEM � VERIFY VERIFY - VERIFY - _ _ POS INSTALLER TO USE DED CIRCUIT AND/OR DATA 800.27 E 1 EXISTING BOTTLE BEVERAGE REFRIGERATOR EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - CHASE # 9.14 IF SUPPLIED tSf. 800.50 E 1 EXISTING EXHAUST HOOD EXIST'I`NG - - - EXISTING EXISTING EQUIPMENT TO REMAIN - 900.57 900.57E1 2 RELOCATED COFFEE BREWER - - _ _ _ _ _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES 800.53 E 3 EXISTING WORKTOP REFRIGERATOR EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - ---- AS REQUIRED R�'�'QfrsiiSy,F 800.58 E 2 EXISTING SLIMLINE BEVERAGE DISPENSER EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - 900.60 900.60E1 1 RELOCATED BLENDER - COUNTERTOP - MCFLURRY - - - - _ _ _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES 800.59 E 1 IEXISTING ORANGE JUICE DISPENSER EXISTING - EXISTING EXISTING EQUIPMENT TO REMAIN - AS REQUIRED 900.82 900.82E1 1 RELOCATED GREASE REMOVAL MACHINE - - - _ _ _ _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES "" 0 800.61 E 1 EXISTING ICE BIN EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN AS REQUIRED z. � u 800.62 E 1 EXISTING FOOD PREP TABLE EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - 900.85 900.85E1 1 RELOCATED MUFFIN TOASTER - - _ _ _ _ _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES U W 800.67 E 1 EXISTING REACH-IN FREEZER EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - AS REQUIRED P2 LL S 800.82 E 1 EXISTING MEAT FREEZER EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - 900.92 900.92E1 1 RELOCATED SHAKE/SUNDAE MACHINE - _ _ _ _ _ _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES z W Z 800.83 E 1 EXISTING WALL FREEZER EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - AS REQUIRED Z =°z 800.84 E 1 EXISTING BISCUIT OVEN EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - 9011.20 901.20E1 2 RELOCATED SPECIALTY COFFEE MACHINE 208/1 - - L5-30R 30A - SEE RMKS EC TO PROVIDE PLUG AND WIRE FROM NEAREST , W Qao 800.86 E 1 EXISTING DRIVE THRU CABINET EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - RELOCATED SPECIALTY COFFEE WORKTOP AVAILIBLE POINT W - 901.23 901.23E1 1 - _ _ _ _ _ _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES �• Z_ <Eo 800.89 E 1 EXISTING GRILL STATION EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - REFRIGERATOR AS REQUIRED 800.91 E 1 EXISTING ICE MACHINE EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - 9011.28 901.28E1 2 RELOCATED BLENDED ICE MACHINE - - - _ _ _ _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES f w W OZa 800.93 E 1 EXISTING CENTER ISLAND CABINET EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - AS REQUIRED ' ,_' W 800.95 E 4 EXISTING HAND SINK EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - 0 Z 800.97 E 1 EXISTING ARCH FRY DISPENSER EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - 4 Q b 800.98 E 1 IEXISTING MOP SINK EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - W n 800.99 E 1 EXISTING SCULLERY SINK EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - " `. •' o 801.06 E 1 EXISTING NAPKIN DISPENSER EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN m 801.35 E 2 EXISTING HIGH DENSITY UNIVERSAL HEATING M 75 Ln EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN CABINET - 2-SIDED ,, 1- 801.36 E 1 EXISTING HEATED LANDING ZONE EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - VIF_verify In Field � C°z 0 PG >•Plumbing Contractor PLUMBING SCHEDULE - _ _ 801.37 E 2 EXISTING CUP LID HOLDER EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - -- 0 w o 801.38 E 7 EXISTING SHELVING EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - ITEM # TAG # QTY DESCRIPTION TYPE GAS BTU GAS SIZE HOT WATER COLD WATER GASMISC HGT AFF DRAIN REQUIREMENTS AND REMARKS a Q 801.41 E 2 EXISTING BULK OIL EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN -- PLUMBING 36" NEXT GEN 3-PLATEN CLAMSHELL GRILL - 801.42 E 1 EXISTING BULK CO2 EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - 96.14 096.14P1 1 - 70,000 _ _ _ _ EXTEND (1) GAS LINE ON CHASE AFTER EQUIPMENT c GAS/ELECTRIC �' 1 - o ° 801.48 E 3 EXISTING KVS MONITOR EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - - ITEM(S) INSTALLED o -o 0 152.06 152.06P1 1 WAREWASHER - UNDERCOUNTED - - - * _ PC TO MAKE ALL CONNECTIONS AS REQUIRED PER E T � -° ° ° c .N 801.49 E 1 EXISTING PRODUCT LANDING SHELF EXISTING - - - EXISTING EXISTING EQUIPMENT TO REMAIN - 1/2" 120 - V-6" 5/8" o o E P LOCAL CODES a 9 0 C ° 4 0 900.27 R 1 RELOCATED ECONOMY OEP BOX EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - 701.08 701.08P1 2 3" FLOOR SINK - 1/2 GRATE - - - - - - 2" VENT - _ o �"" L a °a o o t 3" DRAIN17 900.33 R 1 RELOCATED BUN TOASTER EXISTING - _ - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - 900.45 900.45P1 1 RELOCATED FILET BUN STEAMER - - - _ _ _ ° ` o °' o ° 900.35 R 1 RELOCATED MING OVEN EXISTING - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - _ _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES AS � REQUIRED o a 900.39 R 1 RELOCATED FRONT COUNTER EQUIPMENT EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - --- ° 900.57 900.57P1 2 RELOCATED COFFEE BREWER - - - - _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES AS ° ° ° 0 0 ° ° 900.44 R 1 RELOCATED BUN BOX EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - - - - ° ° .0 3 5 o m REQUIRED o .� a Q 900.45 R 1 RELOCATED FILET BUN STEAMER EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - 900.98 900.98P1 1 RELOCATED MOP SINK - - - _ _ _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES AS o ° KVS SYSTEM TO BE RELOCATED/REDESIGNED BY REQUIRED ° Q) to ° 0 900.46 R 2 RELOCATED/REDESIGNED KVS SYSTEM OWNER - - - RELOCATED - 90.1.20 901.2OP2 1 RELOCATED SPECIALTY COFFEE MACHINE - - - - _ _ a ° E .- �-C 0 0 KVS/POS COMPANY _ __ - 3/4" DRAIN PC TO CONNECT DRAIN LINE TO EXISTING DRAIN C° _ 0 ° o•� a POS SYSTEM TO BE RELOCATED/REDESIGNED BY 90'1.28 901.28P1 1 RELOCATED BLENDED ICE MACHINE - - - - _ _ _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES AS � o o`" o C 900.51 R 4 RELOCATED/REDESIGNED POS SYSTEM OWNER - - - RELOCATED POS COMPANY - REQUIRED ° -° 3 ° c °D 900.57 R 2 RELOCATED COFFEE BREWER EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - 907.28 901.28P2 1 RELOCATED BLENDED ICE MACHINE - - - - _ _ _ _ GC TO VERIFY AND REWORK ALL EXISTING UTILITIES AS ° o .o `o ° C o 900.60 R 1 RELOCATED BLENDER - COUNTERTOP - MCFLURRY EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - REQUIRED (n _, U 0 ° ° o _ a 900.63 R 1 RELOCATED CUP/LID/`SPOON ORGANIZER, MCFLURRY EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - L ° o.D N E ° 900.82 R 1 RELOCATED GREASE REMOVAL MACHINE EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - o o o In c ° 0 0 900.85 R 1 RELOCATED MUFFIN/BAGEL TOASTER EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - ""' 0 U0 0 0 U) 900.92 R 1 RELOCATED SHAKE/SUNDAE MACHINE EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - ° c a a 900.95 R 2 RELOCATED CART EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - < o ° U N_o 900.98 R 1 RELOCATED MOP SINK EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - a° L o U w Cn 901.20 R 1 RELOCATED SPECIALTY COFFEE MACHINE EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - Cn Cn Cn0 .o 901.21 R 1 RELOCATED SPECIALTY COFFEE CUP DISPENSER EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - -o a - Q N ,. T E 901.22 R 1 RELOCATED SPECIALTY COFFEE LID HOLDER EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.0 - V ° ° o w D° a u 901.23 R 1 RELOCATED SPECIALTY COFFEE REFERIGERATOR EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - a,o ° o N ° C C) as 901.28 R 1 RELOCATED BLENDED ICE MACHINE EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - o 3 901.38 R 1 IRELOCATED CUP DISPENSER EXISTING - - - RELOCATED EXISTING EQUIPMENT RELOCATED BY G.C. - l ° o ® ° C w In 0 00 7 U U U U U (L N o 0 � U i w -C a o d m 0 m J D O Li U � Q Lr) L� w N Un N O Q = W N U w a I 0 o Q �� (n o Lj 0 O U O z cv N to r Z W I- Q Z H N O z Q z z � 1 J O � O Q i W O W C:) ° ILi- m LjF- o z t+- W 0 O� I CIO J LlJ O � co Q LD of w Lr) LLJ w CD X O O X I J Un W N W w w f= o cn o TCHHD CCHDDUDHC 031 .1745.00.0 (-T� KK 2 1 NO SCALE w C` KITCHEN SCHEDULES m c o LL ¢ I Qi i j II CYT II DESSERTS () MONITOR Ld !1 GRILL w WALL RECR Cl 84" UNIVERSAL (STATION 0- z ) C FFEE I Z I I C FEE f PRINTER/AB L,J ORDER Y SWITCH EXHAUST HOOD L M� \ U ---- PIE MONITOR y , J HOLDER CHEESE SEAR \ O O O FC HOLDER nuCq 00I -co Do W Q _ O F U n N o —-- ------ FREEZER m W II I OOOO ^^ U Ln ®o S EXISTING 0 STATION L�z (� D CEFRIGERATE (� FRY IIII Lf) J DRAWER HAND z Z I __ W SINK -i � I I U W W LJTLf _ALU , U COMBO DING FRY 4'-0" CENTER ISLAND SHAKE BONOAE REEZER HOLDING STATION 2 ASSEMBLY MAL�HINE COOLER STAND 7'-0„ ( 18„ 1 g„ 2'-3" 2'-3" 3'-04" ol 2'-10" 4'-0" 2'-3" 2'—2,Y4 5'-3„ lool ol 10 CYT/CR ILL DEEVAT OD 2 CDC COFFEE AREA ELEVAT ON3 CCR TER SDAS D ELEVATION K�21 1'-0" 1/4" = 1'-0" K 2. 2 1/4" = 1'-0" W Q 0 NEW I.G. TWIST—LOK Q (VERIFY RECEPTACLE N FORORDk. ONG) NEW PICK—UP ca OCIP SHELF �Y U� tlr�; OEP Q _ N.Fr J -T w � PRINTER CYT GG MONITOR UNIVERSAL � � � ~ g OrAe�E� BUNS TOASTER )` 00 = w �_ —_ �y�yII RAIL � , ~ SCULLERY SINK U — .Y• I I I C) = I I I IT I D-T :rwW CO I OVESIDE OR8g { UZ I __ I ,„;,,0 TOAs CUP/LID BA .NAPKIN @ ., . UU J 10-LLI CARii REFRIGERATOR K CA I I HAND W SINK - z =U Z U.C. U DISHWASHER 50"TOAST TABLE 75"HO PREP TABLE � a .. LW Q d 1 3 " 3 3 " ORB COMPUTER z aFr= 23 4 7 —2 �4 2'-1" —0 4 '2 —5�'014 4'-2" 6'-3" OUTLET V.I.F. ,,.. , ..,- Z wz LOCATION FOR - w L03< )W ORB COMPUTER p z � Q o 4 SCULLERY AREA ELEVATION s PRC UNE AREA ELEVATION 6 FRONT COUNTER CREW ELEVATOR j w� cc ao r 'rn C, K2. 2 1/4" = 1'—O" K 2. 2 _ K 2.2 1/4„ = 1'-0" Q ",� Lu "o / 1/4" - 1'-O" LTJ � mzo Q = D_ W F"1, zitcc n Q 2 a c o o � ORDER O O_ U O ° 0 a� 0 0 ere O o ° o 0 READY >, � � ° � c U N BOARD U (j a a U ° O ° as > o ° Q 0 0 -- OUPRIGHT Q ^ 0 C U E O COc N.N O O U 0 TOMATO U U C N U f--� —_1 I COOLER vj IrIr-1 I / / ------- I'L=J11 IL ✓ IL=�I1 a ° ° °'o a c .O o � 3 0 ° °� O W BISCUIT OU ° — C p -O OVEN N p 0 0 0 C O J PRESENT ORDERINS o EZ ° c ° ° ° O _E u0 J~ _� U N ol ° Q Q)a u U C cn RIS U r-/--� FRCINT COUNTER CUSTOMER EEEVAT OR (-8--� TOMATO COOLER AREA DEDVAT OR a� ° Q ° ` � E K 2. 2K 1/4„ = 1'-0" 2. 2 1/4„ = 1'-0" 1E° Q� fs� c Lo ._ c O.3 v W U U O O O ® 3 0 0 w O._ ° rn c � NU) N O Q (n d0 13 U) (D U U DL. O i p G) � N a3 c cn 0_ m o 0 — L' O w L_ w N Q n N O c) Q = w N cn U a_ w 0 oQ � � o � c� U c O cv N Z L) O W Q O CD^ Z �J Q Z z W' W FI O (n O —� Q L� W 0 cj� c O w In 'o LL CQ LL,J Q z W w O O UT O v~ m Go LLJ - Q W z Z U Z Ln OOl W W >Li W O O X w o w � , N W o cn o 031 .1745.00.0 w o K 2 . 20 EXISTING EQUIPMENT NEW EQUIPMENT RELOCATED EQUIPMENT 0 OPTIONAL/FUTURE EPMENT W Z QUI N KITCHEN ELEVATIONS m z 0 0 U) w 0 GENERAL ELECTRICAL NOTES ELECTRICAL SYMBOL LEGEND W INSTALLATION METHODS SYMBOL/ABBR. DESCIIPTION o 1. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A QUALIFIED, LICENSED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLEE ELECTRICAL ROUGH-IN NUMBER NATIONAL, STATE AND LOCAL CODES. 2. ALL ELECTRICAL WORK SHALL BE INSTALLED IN A NEAT, PROFESSIONAL, AND WORKMAN LIKE MANNER. FINAL INSTALLATION DUPLEX CONVENIENCE OUTLET SHALL BE COMPLETE, SAFE AND CODE COMPLIANT. � •�� 3. EXTENSION CORDS SHALL NOT BE UTILIZED UNDER ANY CIRCUMSTANCES. QUADRAPLEX CONVENIENCE OUTLET 4. ALL ELECTRICAL MATERIAL USED ON THIS PROJECT SHALL BE NEW, "UL" LISTED AND LABELED. 1,f`� • �y �'� � i JUNCTION BOX - WALL OR CEILING t fti6�� 5. ALL DIMENSIONS SHOWN ARE TAKEN FROM FACE OF WALL FINISH. THE EC SHALL MAKE NECESSARY DIMENSIONAL QMOUNTED c�� ALLOWANCES. ALL DIMENSIONS SHOWN ARE TO CENTER LINE OF OUTLET BOX AND/OR RECEPTACLE UNLESS SPECIFICALLY NOTED OTHERWISE, PLUMBING SYMBOL LEGEND '= }r.." UL 0 SPECIAL PURPOSE OUTLET 6. ALL J-BOXES, DCOS, AND OTHER ELECTRICAL DEVICES SHOWN SHALL BE RECESSED MOUNTED INTO A WALL, FLOOR OR SYMBOL/ABBR. DESCIIPTION CEILING UNLESS SPECIFICALLY NOTED OTHERWISE. 1G 7. ALL RECEPTACLES (EXCEPT SPECIFIED HUBBELL PIN AND SLEEVE TYPES) SHALL BE FURNISHED BY THE EC. THE ® ISOLATED GROUND OUTLET ####�� PLUMBING ROUGH-IN NUMBER RECEPTACLES, INCLUDING SAID PIN AND SLEEVE TYPE RECEPTACLES, SHALL BE INSTALLED BY THE EC. 10 BEVERAGE/SODA CONDUIT 8. EC SHALL PROVIDE AND INSTALL STAINLESS STEEL COVER PLATES ON ALL RECEPTACLES AND J-BOXES. ADDITIONALLY, EC NON-FUSED DISCONNECT SWITCH 00 SHALL PROVIDE AND INSTALL ORANGE NYLON COVER PLATES MARKED "COMPUTER ONLY" ON ALL ISOLATED GROUND/DEDICATED CIRCUIT ® REFRIGERATION LINE U waN RECEPTACLES. PURCHASE PJ8CO (ONE DUPLEX) OR PJ82CO (TWO DUPLEX) FROM HUBBELL. EXHAUST DUCTII X00 9. EC SHALL COORDINATE WITH KITCHEN EQUIPMENT SUPPLIER, MECHANICAL CONTRACTOR AND GC FOR FINAL LOCATIONS AND l9du 701.08 P1 FLOOR SINK ., z W Z A AMPERES }} ., f _ =Uz CONNECTION REQUIREMENTS OF ALL EQUIPMENT PRIOR TO INSTALLATION OF ANY CONDUIT AND/OR STUB-UP LOCATIONS. a ACM AREA CONSTRUCTION MANAGER 701.10 P1 FLOOR DRAIN ,R.,-, w <Z 10. CEILING MOUNTED ECONOMY OEP BOXES ARE FURNISHED BY McDONALD'S, AND INSTALLED BY THE GC. CORD AND PLUG SET z woo FURNISHED BY THE KES ARE TO BE INSTALLED BY THE EC. AFF ABOVE FINISHED FLOOR r WZFr= 11. FOR GRILLS, FRYERS AND ANSUL SYSTEMS, EC SHALL EXTEND CONDUIT AND CONDUCTORS DOWN CHASE OR WALL TO BFC BELOW FINISHED CEILING I HOSE BIBB ,. z o W a TERMINAL BLOCK MOUNTED ON EQUIPMENT AND MAKE FINAL CONNECTIONS TO TERMINAL BLOCKS PER JURISDICTION HAVING AUTHORITY. w 12. ALL HOLES IN THE FRONT COUNTER FOR THE POS CORDS AND CABLES SHALL BE LOCATED BY OWNER AND DRILLED BY GC. CBB CIRCUIT BREAKER G EXHAUST DUCTz Q s 13. ALL ELECTRICAL CONDUCTORS SHALL BE CONNECTED TO RECEPTACLES USING ONLY THE TERMINAL SCREWS. RECEPTACLE CCT CIRCUIT w BACK WIRE/QUICK CONNECTIONS SHALL NOT BE USED. ACM AREA CONSTRUCTION MANAGER ` DCO DUPLEX CONVENIENCE OUTLET 0 14. POWER AND CONTROL CORDS ARE FURNISHED WITH KITCHEN APPLIANCES. THE EC SHALL CONNECT CORD SETS TO AFF ABOVE FINISHED FLOOR Om(n > ~ Cn I APPLIANCES AS REQUIRED PER JURISDICTION HAVING AUTHORITY. GFC/GFCI GROUND FAULT CIRCUIT INTERUPTER BFC BELOW FINISHED CEILING '-'�' -Lij "� o mo m 15. NON-METALLIC SHEATHED GABLE (ROMEX, NM, NMC, & NMS), ARMORED CABLE TYPE AC (BX) AND ELECTRICAL GRD GROUNDLZ NON-METALLIC TUBING, TYPE ENT SHALL NOT BE USED AS WIRING METHODS. BSI BEVERAGE SYSTEM INSTALLER a_ U c 16. MINIMUM WIRE SIZE SHALL BE #12 AWG COPPER UNLESS NOTED OTHERWISE. MINIMUM CONDUIT SIZE SHALL BE 1/2" UNLESS JB JUNCTION BOX CO CLEAN-OUT a Q coo: OTHERWISE NOTED. WIRE INSTALLED UNIDERSLAB SHALL BE THW. ALL HOME RUNS SHALL BE SIZED BY THE EC ACCORDING TO THE NEC. KW KILOWATT EC ELECTIRICAL CONTRACTOR 17. ALL WIRING SHALL BE INSTALLED IN RACEWAYS CONSISTING OF THE FOLLOWING MATERIAL: -METALLIC: EMT, IMC HEAVY-WALL CONDUIT. (AS PERMITTED BY LOCAL CODES) GC GENERAL CONTRACTOR GC GENENAL CONTRACTOR o °�� a o N ° K -METAL CLAD CABLE - MAX. 6' LENGTHS FOR LIGHTING ONLY (AS PERMITTED BY LOCAL CODES ES KITCHEN EQUIPMENT SUPPLIER FRANKE a oa CL ( ) KES KITCHEN EQUIPMENT SUPPLIER (FRANKE) v i 2 -' _ED �oo 18. EQUIPMENT REQUIRING ELECTRICAL POWER TO OPERATE,(FINAL CONNECTION,WIRING,HOOK-UP,ETC.)SHALL BE DONE BY THE EC ELECTRICAL CONTRACTOR PC PLUMBING CONTRACTOR ° w�e,�ed ELECTRICAL CONTRACTOR. a ° 0 19. THE ENTIRE REFRIGERATION SYSTEM SHALL BE WIRED AND CONNECTED BY THE ELECTRICAL CONTRACTOR AS DIRECTED BY GENERAL MECHANICAL NOTES ° ° , ° THE KITCHEN EQUIPMENT SUPPLIER. 0 o 3 U)i� ° ° a U) n_ - GENERAL PLUMBING NOTES ROUGH-INS (NEW & RELOCATED KITCHEN EQUIPMENT) INSTALLATION METHODS ( o ° C Qp d 1. ALL ELECTRICAL ROUGH-INS SHOWN ON THIS PLAN SHALL INCLUDE AN INSULATED COPPER EQUIPMENT GROUNDING 1. ALL WORK PERFORMED SHALL BE IN ACCORDANCE WITH ALL LOCAL CODES AND ACCEPTABLE TO THE AUTHORITY HAVING ° 3 ° CONDUCTOR CONTAINED WITHIN THE SAME CONDUIT AS THE CIRCUIT CONDUCTORS AND SIZED PER NEC. INSTALLATION METHODS JURISDICTION. _ ° ` o 2. ROUGH-INS FOR EXISTING EQUIPMENT TO REMAIN ARE NOT SHOWN ON THIS PLAN. FOR EACH JOB, EC TO VERIFY WITH 1. ALL WORK SHALL BE PERFORMED BY A QUALIFIED, LICENSED PLUMBER IN ACCORDANCE WITH ALL APPLICABLE NATIONAL, STATE 2. ALL DIMENSIONS, CLEARANCES AND TOLERANCES SHALL BE VERIFIED PRIOR TO INSTALLATION. ( N a McD PROJECT MANAGERKES WHICH EXISTING EQUIPMENT WILL REMAIN AND IF IT WILL BEso 0 OWNER OPERATOR OR STORE MANAGER AND LOCAL CODES. / / 3. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH ITS LISTING AND/OR THE MANUFACTURER'S INSTALLATION o ° o RELOCATED. 2. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH ITS LISTING AND/OR THE MANUFACTURER'S INSTAL!ATION INSTRUCTIONS. ° ° 0 X ° ° -i 3. OEP BOXES SHALL BE LOCATED DIRECTLY OVER KITCHEN EQUIPMENT. THEY SHALL NOT REMAIN OR BE PLACED OVER AISLES. INSTRUCTIONS. 4. ALL PENETRATIONS OF FIRE-RATED WALLS SHALL BE FIRESTOPPED WITH AN APPROVED AND LISTED FIRESTOPPING SYSTEM. cu ~ ° o 4. OEP CORD LENGTHS SHALL BE ADJUSTED TO PREVENT THEM FROM IMPEDING PREPLINE FUNCTION AND TO PREVENT CONTACT 3. CLEANOUTS SHALL BE INSTALLED AT ALL CHANGES OF DIRECTION GREATER THAN 45° . WHERE MORE THAN ONE CHANGE OF 5. THE GENERAL CONTRACTOR SHALL STUDY THE MECHANICAL ROUGH-IN PLAN PREPARED BY McD'S PRIOR TO INSTALLING ANY WITH ANY HOT SURFACES THAT WILL DAMAGE CORDS OR PLUGS. DIRECTION OCCURS IN A SINGLE PIPE RUN, ONLY ONE (1) CLEANOUT SHALL BE REQUIRED FOR EVERY 40 FEET OF DEVELOPED LENGTH. BASES, SLAB POURING, ERECTING UTILITY CHASES OR PROVIDING FOR ANY INSTALLATION CONNECTED WITH THE INSTALLATION EQUIPMENT. .- D o ° ° ° C "I IDU 4. CLEANOUTS SHALL BE INSTALLED ON PIPES PRIOR TO ANY SLAB PENETRATION. 6. THE MECHANICAL CONTRACTORS ARE TO STUDY ALL FIXTURE LEGENDS ON ALL SHEETS AND ALL RELATED DETAILS BEFORE t-: ° ELECTRICAL PANELS 5. WHERE PIPING IS LOCATED WITHIN WALL CAVITIES, ACCESS TO THE CLEANOUTS SHALL BE PROVIDED. PROCEEDING WITH ANY ROUGH-IN WORK. ° o s 1. THE EC SHALL BE RESPONSIBLE FOR BALANCING THE LOADS ON ALL PANELS CHANGED BY THIS PROJECT. 6. ALL FLOOR DRAINS THAT DO NOT SERVE EQUIPMENT SHALL BE (PROTECTED AGAINST DRYING OUT EITHER THROUGH THE 7. ALL MECHANICAL WORK PERFORMED SHALL BE PERFORMED IN A NEAT, PROFESSIONAL, AND WORKMAN LIKE MANNER. FINAL L) ° o ° Q 0 2. EC IS RESPONSIBLE TO VERIFY SUBPANEL'S CAPACITY TO HANDLE ANY NEW OR RELOCATED LOADS FOR THE REMODEL, PRIOR INSTALLATION OF A TRAP PRIMER OR PROSET TRAP GUARD. INSTALLATION SHALL BE COMPLETE, SAFE AND CODE COMPLIANT. ° ° ° ° �� �Q� TO PERFORMING ANY WORK. 7. ALL PLUMBING WORK PERFORMED SHALL BE PERFORMED IN A NEAT, PROFESSIONAL, AND WORKMAN LIKE MANNER. FINAL o ® .o o i o o.3 0 3. EC IS RESPONSIBLE FOR THE PROPER IDENTIFICATION AND LABELING OF ALL CIRCUIT BREAKERS ADDED, REMOVED, OR INSTALLATION SHALL BE COMPLETE, SAFE AND CODE COMPLIANT. 3 ° RELOCATED BY THIS PROJECT. NEW PANELS SHALL BE PROVIDED WITH A TYPEWRITTEN CIRCUIT DIRECTORY. ANY CHANGE TO ANY COMMERCIAL KITCHEN EXHAUST SYSTEMS (D 0 1) D u ° Q Vl Q ° 6 N ° EXISTING PANEL WILL REQUIRE THE PANEL DIRECTORY TO BE UPDATED IN THE METHOD DESCRIBED ABOVE TO ACCURATELY REFLECT ITS NOTES 1. ALL METAL DUCTWORK USED FOR THE CONVEYANCE OF GREASE-LADEN AIR SHALL BE CONSTRUCTED OF MINIMUM 18 GAUGEQ) 6 CURRENT STATE. 1. ALL WORK SHALL BE COORDINATED BETWEEN THE McDONALD'S AREA CONSTRUCTION MANAGER, G.C., ALL SUBCONTRACTORS, STAINLESS STEEL OR 16 GAUGE CARBON STEEL. a_ 4. EC SHALL PROVIDE ELECTRICAL SERVICE TO EQUIPMENT MOUNTED BREAKER PANEL. FRANKE, AND THE DECOR PACKAGE SUPPLIER & INSTALLER. 2. ALL GREASE EXHAUST DUCTWORK JOINTS SHALL BE EITHER TELESCOPING OR BELL TYPE. BUTT-WELDED JOINTS ARE PROHIBITED. w (_o 5. IF THE PREP LINE/CENTER ISLAND TABLE ALLOWS THE RE-USE OF THE EXISTING 150A CENTER ISLAND PANEL, IF POSSIBLE, 2. THE BEVERAGE SYSTEM INSTALLER FURNISHES, RUNS, AND CONNECTS ALL FLEXIBLE WATER AND SYRUP LINES FOR ALL 3. ACCESS PANELS SHALL BE PROVIDED AT ALL CHANGES IN DIRECTION OF THE GREASE EXHAUST DUCTWORK SYSTEM. ACCESS m o m J ow v Ln REPLACE CIRCUIT BREAKERS IN CENTER ISLAND DISTRIBUTION PANEL WITH 22,000 AIC RATED BREAKERS OR ADD A CURRENT LIMITING AFFECTED EQUIPMENT INCLUDING THE FOLLOWING: PANELS SHALL BE INSTALLED IN ACCORDANCE WITH THE INSULATION MANUFACTURER'S INSTALLATION INSTRUCTIONS AND SHALL BE z w "� Q w o DEVICE INTO THE CENTER ISLAND FEEDER CIRCUIT THAT WILL LIMIT THE FAULT CURRENT TO LESS THAN 10,000A OR REPLACE THE A. HOT CHOCOLATE LABELED AS FOLLOWS: "ACCESS PANEL - DO NOT OBSTRUCT" < ° n = Li 'Z w " FEEDER BREAKER WITH A BREAKER THAT IS SERIES RATED WITH THE BREAKERS IN THE CENTER ISLAND PANEL. B. COFFEE MACHINES u w a 4. ANY MODIFICATIONS OF EXISTING KITCHEN EXHAUST HOODS, EXHAUST FANS AND CARBON STEEL DUCTWORK ARE TO BE MADE IN o o Q > o C. ICE MACHINES ACCORDANCE WITH THE MOST RECENT EDITION OF NEPA-96, STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL c Qa 0 LIGHTING D. ORANGE JUICE COOKING OPERATIONS. THIS INCLUDES: CLEARANCES TO COMBUSTIBLE MATERIALS, FIRE CHASES/FIRE WRAPS, DISCHARGE POINT OF 1. EC SHALL FIELD VERIFY THAT LIGHT FIXTURES DO NOT OBSTRUCT OR CONFLICT WITH THE WORK OF OTHER TRADES. IF A E. SODA TOWERS EXHAUST IN RELATION TO FRESH AIR INTAKES, WALLS AND ADJACENT BUILDINGS, ETC. � DISCREPANCY IS FOUND, THE EC SHALL RELOCATE LIGHT FIXTURES AFFECTED BY THIS PROJECT TO ACCOMMODATE EQUIPMENT WHILE 3. ALL WATER HEATERS INSTALLED IN McDONALD'S RESTAURANTS SHALL BE HIGH EFFICIENCY SEALED-COMBUSTION WATER 5. ANY ANSUL R-101 AND PRE UL-300 R-102 FIRE SUPPRESSION SYSTEMS THAT ARE ENCOUNTERED ARE TO BE REPLACED WITH MAINTAINING A UNIFORM LIGHTING PATTERN. TO ACCOMPLISH UNIFORMITY, NEW FIXTURES MAY NEED TO BE ADDED. NEW FIXTURES HEATERS. THE INSTALLATION OF STANDARD EFFICIENCY GRAVITY-VENTED WATER HEATERS IS PROHIBITED. ANSUL UL-300 SYSTEMS. (ANSUL IS NO LONGER SUPPORTING R-101 AND PRE UL-300 R-102 FIRE SUPPRESSION SYSTEMS. SHALL BE OF SIMILAR TYPE TO EXISTING FIXTURES. IN ANY CASE, A LIGHTING LEVEL OF 50 FOOTCANDLES 1S THE REQUIRED MINIMUM IN ) Z 4. THE AREA CONSTRUCTION MANAGER, PLUMBING CONTRACTOR AND FRANKE SHALL COORDINATE WHICH 3-COMPARTMENT SINK IS 6. RELOCATE ANY HVAC SUPPLY DIFFUSERS THAT INTERFERE WITH THE CAPTURE OF COOKING VAPORS AT EXHAUST HOODS OR Y THE KITCHEN AREA. BEING INSTALLED IN THE RESTAURANT. NOTE: THE INSTALLATION OF A POWER SOAK SINK REQUIRES A LARGER WATER HEATER THAN THE DISCHARGE AIR DIRECTLY ONTO HEATED SURFACES. (DIFFUSERS SHOULD BE POSITIONED OVER AISLES AND TO THE SIDES OF EXHAUST STANDARD 3-COMPARTMENT SINK. HOODS.) ABANDONED CONDUITSMIRING 5. ALL DIMENSIONS SHOWN ARE SURFACE FINISH TO SURFACE FINISH. PC TO MAKE ALL NECESSARY ALLOWANCES TO HOLD SHOWN 1. ABANDONED WORK: CUT, REMOVE RACEWAY 2 INCHES BELOW THE SURFACE OF ADJACENT CONSTRUCTION AND ABANDON DIMENSIONS. 7. PROVIDE AN "AIR BALANCE" OF THE RESTAURANT IF THE TOTAL AMOUNT OF AIR EXHAUSTED IS REVISED DUE TO CHANGES IN 6. DIMENSIONS SHOWING THE LOCATION OF DRAINS AND FLOOR SINKS ARE CENTERLINE DIMENSIONSTHE COOKING APPLIANCES PRESENT. (A THREE-VAT FRYER IS INSTALLED IN THE PLACE OFA TWO-VAT FRYER) REMAINING RACEWAY IN PLACE. CAP AND PATCH SURFACE TO MATCH EXISTING FINISH. DE-TERMINATE AND REMOVE ALL UNUSED . 8. ALL CARBON STEEL DUCTWORK TO BE SIZED TO PROVIDE A MINIMUM TRANSPORT VELOCITY OF 1500 FPM ,AND A MAXIMUM OF W WIRING. 2100 FPM. > NATURAL GAS SYSTEMS (IF APPLICABLE 9. EQUIPMENT VENTILATOR WIRING IS TO AN INTERLOCK SYSTEM PROVIDED AS PER MCDONALD'S SPECIFICATIONS. ( PRINTERS ETC.) 1. ALL GAS PIPING FOR COOKING EQUIPMENT SHALL TERMINATE IN THE CEILING PRIOR TO THE INSTALLATION OF THE PIPING CHASE. o Q N POS EQUIPMENT WIRING POINT OF SALE - COMPUTERS, MONITORS, KVS MONITORS, UPON INSTALLATION OF THE CHASE, THE GAS PIPING SHALL THEN BE CONTINUED IN THE CHASE FOR THE FINAL CONNECTION TO THE � W Z 1. ALL NEW ELECTRICAL CIRCUITS FOR ANY POS EQUIPMENT SHALL BE OF THE "ISOLATED GROUND/DEDICATED CIRCUIT TYPE. APPLIANCE. REFRIGERANT PIPING z w � 1. ALL REFRIGERATION WORK SHALL BE PERFORMED BY A CERTIFIED REFRIGERATION CONTRACTOR. (FINAL ELECTRICAL CONNECTIONS J ° 2. ALL S CIRCUITS SHALL BE POWERED FROM THE SAME PHASE (TYPICALLY PHASE C) 2. ALL GAS PIPING, WATER HEATER VENTS, INTAKES AND FLUES SHALL CONFORM TO THE CURRENT VERSION OF NEPA 54, Q � TO BE PERFORMED BY THE EC. 0 3. E.C. TO CHECK AND VERIFY THAT ALL EXISTING POS CIRCUITS CONFORM TO "ISOLATED GROUND/DEDICATED CIRCUIT" DETAIL NATIONAL FUEL AND GAS CODE, AND ANY LOCAL CODE REQUIREMENT. ) o W o ° PRIOR TO CONNECTION AND INSTALLATION OF ANY NEW POS EQUIPMENT. IF ISOLATED GROUND/DEDICATED CIRCUIT IS NOT IN 3. GAS PIPING SHALL NOT PENETRATE ANY FIRE-RATED CHASE OR SHAFT, DUCTWORK, OR PLENUM. 2. ALL REFRIGERANT PIPING SHALL BE SEAMLESS COPPER TUBING OF TYPE L IN ACCORDANCE WITH ASTW B 88 AND ALL JOINTS m w o COMPLIANCE WITH DETAIL, NOTIFY OWNER/OPERATOR OR STORE MANAGER/McD PROJECT MANAGER OF NON-COMPLIANCE. DETERMINE 4. AFTER PERFORMING THE REQUIRED PRESSURE TESTING AND ANY LEAKS REMEDIED, THE INSTALLING CONTRACTOR SHALL SHALL BE SOLDERED, w w o COURSE OF ACTION WITH ALL APPROPRIATE PARTIES, RE-ESTABLISH ISOLATED GROUND/DEDICATED CIRCUIT OR USE LINE CONDITIONERS. MEASURE AND VERIFY THE FOLLOWING GAS PRESSURES WHILE EQUIPMENT IS IN OPERATION: 3. ALL REFRIGERANT LIQUID LINES SHALL BE INSULATED TO PREVENT AGAINST CONDENSATION. CO J N o CAUTION: EVEN IF ISOLATED GROUND/DEDICATED CIRCUIT IS WIRED CORRECTLY THE ELECTRICAL ENVIRONMENT MAY STILL REQUIRE THE A. GRILL - 5" W.C. NATURAL, 10" W.C. LP. 4. ALL REFRIGERANT PIPING SYSTEMS SHALL BE PRESSURE TESTED FOR LEAKS PRIOR TO START-UP. ALL LEAKS SHOULD BE W z z z REMEDIEDBEFORE TURNOVER. USE OF LINE CONDITIONERS TO PROVIDE POWER CLEAN ENOUGH FOR THE POS. THEREFORE, IT MAY BE MORE COST AND TIME B. FRYER - 3 -1/2" W.C. NATURAL, 8 -1/4" LP LO w w a o EFFECTIVE, PROVIDED THE EXISTING WIRING OFFERS A GOOD GROUNDING PATH, TO UTILIZE LINE CONDITIONERS INSTEAD OF TRYING TO C. WATER HEATER - 5' W.C. NATURAL, 11' W.C. LP o � RE-ESTABLISH ISOLATED GROUND DEDICATED CIRCUIT WIRING. W w W / D. HVAC UNIT - 5" W.C. NATURAL, 11' W.C. LP �� � � � NOTES O �� � 4. CONTACT REGIONAL CONSTRUCTION MANAGER FOR LINE CONDITIONER INFORMATION PACKAGE. COORDINATION WILL BE IF THESE PRESSURES ARE NOT MET, THIS SHALL BE REPORTED IMMEDIATELY TO THE McDONALD'S AREA CONSTRUCTION MANAGER. 031 .1745.00.0 REQUIRED BETWEEN HUBBELL AND THE POS SYSTEM SUPPLIER TO DETERMINE THE EXACT NUMBER OF UNITS REQUIRED PER STORE. (TYP. 6-7 UNITS) K243N40SCALE w K2 * 3 w n KITCHEN NOTES m z 0 v CLI cn w 0 Li Q 0 Li m Q W N � H� a W Q N i W p W d' O =UZ Wa w�� Z r Z QEo �W= j \ \ MDP AP-2 I G- z o F,< \ AP-1 I j \ p W O W Z Q o Lr n �� o 0 W Q)0 o0 w F= m 00 Q _ Z rn II II ❑ ❑ a_ () oda O II II Q In II II o • Q O I II II / II II x I I / o a _0 o o Q) o N II II o o- o o ° - I I I I r - � - - -- o c: II o pO - � � _ C� o + _ cn C.) N - O U � _--- o �o cO O ' U C O 030c: CD C - O s - c ° � C-) 0 0 0 o c o 900.60 E1 9" HOLD 21' _.- 0 O a °' o o ° H -•-- - O .-, x . I I I O % U 152.06 E1 L 3' 7 4, g�2„ o f o ° ® 10 I ( 7 -114 - _ o0 0 I I / 215.04 E2 iNl N a I -- ate " o 0) w 215.04 E5 = % - c�I� 900.51 1 - o o I I 23.57 E1 I r i _ ° 219.00 E5 - N N CO I 1 1 i o Q o o Q o 0 219.00 E6 = N I i i ;------ u o�° o Q ° X xx� - 207.32 E1 a �• c El --- C� Cii O � 3 - c °J 3 ° LP 207.31 E1 o .3 0 ° o J aI a2�' \ \ II 900.57 E1 - CO � ojN ° vo 900.57 E1 `V -- j ii c. C• c• o� , " 900.92 E1 ��C` �`O�I ('C�, !�C` ° -- - - " (9=0.51 E1 O E1 I --------- C900.82 aI 13" 10'-2" L�--j -� a C` w p ! O ! ! �' ------ - co n 900.2 E1 a r m �r 215.04 E1 a l m n 0 o w 143.00 E3 % c L� 177.06 E1 ' ' 215.04 E2 a % z w N " N o 00.8 E1 �- w NEW ELECTRICAL _ N 900.46 E1 219.00 E1 --1 a RECEPTACLE FOR ORB. � ~ w U 1(9M_351E1 a Oi OO' Orl ® QLi n c\oCD i,. _ O O I I l a l VERIFY LOCATION IN ---- • CEILING O I a I 215.04 E1J00 216 05 E1 m °' -- 215.04 E2 I ii N 9' 934„ 7'-8" 219.00 E1 _ 219.00 E2 NEW RECEPTACLES CD FOR MINI ORB u TO USE r Ej ;El R_ - AND SCANNER - EXISTING 1 GRILL / ----------- -------- HOOD n 12" 3'-4" - - - I I ------ w I i ---------' z F-- N O r n Z J Q Z z ww _ w or� 215.04 E1 _ o 901.28 E1 901.20 E1 D Q c 215.04 E2 w 215.06 E1 901.28 E1 901.20 E1 o w c •a 215.06 E3 900.51 E1 901.23 E1 M a F- L, o AS-BUILT CONDITIONS IN THIS DRAWING SET ARE DRAWN AND z o Li � 00 co VERIFIED BY OTHERS. FRANKE FOODSERVICE SYSTEMS, INC. IS NOT W < Q RESPONSIBLE FOR ANY ERRORS OR DISCREPANCIES AS A RESULT o U w OF AS-BUILT DRAWINGS. USAGE OF THIS DRAWING RELEASES CD �_ Li w o FRANKE FOODSERVICE SYSTEMS, INC FROM ANY LIABILITY RELATED TO EXISTING CONDITIONS AND AS-BUILT DRAWINGS ERRORS OR TC H C CC C E C TH C A ROUGH - IN H C A �l N W cl)Li w N o DISCREPANCIES. KEI AND GENERAL CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS BEFORE BEGINNING ANY WORK. E� • � 1/4" - 1'=0" 031 .1745.00.0 EXISTING EQUIPMENT NEW EQUIPMENT RELOCATED EQUIPMENT TI OPONAL/FUTURE EQUIPMENT o K E 1 • w �.�/ KITCHEN ELECTRICAL C2 z 0 IZ Li 0 Li Q 0 w w 110 O WQ W N H N R^ Q r� e • � �U p w o z Fwz _ =UZ U U l Lli d N w H ZCR Z aEo AP-2 wx NWS MDP a AP-1 Z O F LL1 O w Z QLLJ (D o r7 IYO m owa)oNIT O * Q 2 mz) r1E w U ° 0 o OO o c \ / O N ysj /x\ I q�M! O a a ° O C O L O a N N e p O a N O O O 'O U --------F---�--,' C 0 r% ° � N .o c o -' O O c ° c --------- ♦dry a E :-2C@DD ° o0 C 6)O_ co 0 ' O U O ,,d ; ' I/7 U N N 'x L O (EKD --------------------- _ ` C L — — ° 9. 0 0 O __j � r. U) oo152.06 P1 Nc' O U flp I O L (2, 0 T I d l a 0 O w D O S D !ems O ° n 0- -o LP 900.57 P1 �i a n n � c �,".4 - .`_ _a (900.571 P1 -- a' p lL —1 r o o D o _ ® -� .� 3 O _ O .-. 3 0 N._ TJ U c 5'-10%4" 2'_g° m I o o Q Q) a o D Lo � Y o __ _ I a ; ,,0; ,0; .O w � o N I � � - o r p t COO bI - w N iLn - --------' Q m o U � I I m o O Q D CN -w 14,_03/ CN 4„ ol --J i �s z N .. 0 0 w _ L , ' I � � ® � Ci' � � � ' Cil O � m � w (n Q a I O- ,0., ,O' ,0,, o O O Q � a � � 0- u 0 (_oCN� II TO USE EXISTING GRILL HOOD Iq 900.45 P1 � - - - - - - 96.14 P1 (701.081 P1 701.08 P_ U 29'-10" 2'-6" ol ---------- �__� ° t LLJ ` _m T_A I I J � ' -------- ---------- Q z H N O 0 Z z � LTJ w 0 Z 31 –1" 23" 12" 4'-6" — _J ° c 901.28 P1 � m oL'J � Q 901.28 P2 z L, Li o AS–BUILT CONDITIONS IN THIS DRAWING SET ARE DRAWN AND 901.20 P2 0 0 – 0 6 co VERIFIED BY OTHERS. FRANKE FOODSERVICE SYSTEMS, INC. IS NOT J RESPONSIBLE FOR ANY ERRORS OR DISCREPANCIES AS A RESULT o W Lo OF AS–BUILT DRAWINGS. USAGE OF THIS DRAWING RELEASES (n 7E o FRANKE FOODSERVICE SYSTEMS, INC FROM ANY LIABILITY RELATED TO EXISTING AS—BUILT DRAWINGS V PLUMBING ~ LLJ o wo � o DISCREPANCIES. KEIND GENERAL CONTRACTOR TO FIELD VERIFY KITCHE \ OEDHOAD DOUGH — H HOAU o EXISTING CONDITIONS BEFORE BEGINNING ANY WORK. P 031 .1745.00.0 bbi EXISTING EQUIPMENT 0 0 NEW EQUIPMENT RELOCATED EQUIPMENT 0 OPTIONAL/FUTURE EQUIPMENT w KPl 0 cn KITCHEN PLUMBING