Loading...
HomeMy WebLinkAbout40732-Z �o�ps�'FF��'�Co� Town of Southold 7/28/2016 � y� P.O.Box 1179 0 W � 53095 Main Rd oy.jj�� �ao`"� Southold,New York 11971 � CERTIFICATE OF OCCUPANCY No: 38420 Date: 7/28/2016 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 4995 Sound Ave.,Mattituck SCTM#: 473889 SecBlock/Lot: 121.-1-3.3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/20/2016 pursuant to which Building Permit No. 40732 dated 5/31/2016 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF-MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to McDonough,Grace of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40732 07-12-2016 PLUlVIBERS CERTIFICATION DATED � � - uthorized Signature 4�S�F��,co TOWN OF SOUTHOLD �� �y BUILDING DEPARTMENT � = TOWN CLERK'S OFFICE oy. . o�,� SOUTHOLD, NY , �ip! � �,a BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREIVIISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40732 Date: 5/31/2016 Permission is hereby granted to: McDonough, Grace 4995 Sound Ave Mattituck, NY 11952 To: �nstall roof-mounted solar panels as applied for. At premises located at: _ 4995 Sound Ave., Mattituck SCTM #473889 � Sec/Block/Lot# 121.-1-3.3 Pursuant to application dated 5/20/2016 and approved by the Building Inspector. To expire on 11/30/2017. � Fees: CO -ALTERATION TO DWELLING $50.00 SOLAR PANELS $50.00 LECTRIC $100.00 � Total: $200.00 ,� , , f , Building c or Form No.6 � TOWN OF SOUTHOLD BUII,DING DEPARTMENT TOWN HALL 765-i802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For e�usting buildings (prior to Apri19, 1957) non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certif'icate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial $15.00 Date. J� �O�b"/b New Construction: Old or Pre-existing Building: X (check one) LocationofProperty: 4'995 Sound Avenue Mattituck House No. Street Hamlet Owner or Owners of Property: GraC@ MC�OC10Ugh Suffolk County Tax Map No 1000, Section �2� Block � Lot 3.3 Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant:Scott Maskin-SUNation Solar Systems, Inc. Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ � " .. Applicant Signature ����pF SO!/r�,�l 0 Town Hall Annex � � Telephone(631)765-1802 54375 Main Road y � Fax(631)765-9502 P.O.Box 1179 � • �Q roqer.richertCa�town.southold.nv.us Southold,NY 11971-0959 Q l'�cOU�TY,�� BUII.DING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: McDonough Address: 4995 Sound Avenue City: Mattituck St: New York Zip: 11952 Budding Permit#: 40732 Section: 121 Block: 1 Lot:" 3.3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: SUllatl011 SOIaI" License No: 33412-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceilmg Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Svwtches Twist Lock Ewt Fixtures TVSS ome�Eq��Pme�t: 5.670 KW Roof Mounted Photovoltaic System to Include; 18-LG 315 Panels, 1-SE 5000 Inverter, 1-60 A/C Disconnect. Notes. Inspector Signature: _ Date: July 12, 2016 z Electrical 81 Compliance Form.xls Fisher Engineering Services, P.C. PO Box 30 • Oakdale •New York 11769 t� Phone: (631) 563-9028 � � r� � D June 24, 2016 � �: JUL 2 8 2016 Building Department ���ING DEp�' Post Structural Certification T��'NOFSOUTgpT,p McDonough Residence—4995 Sound Avenue, Mattituck,NY 11952 Permit No. 40732 I have verified the adequacy and structural integrity of the existing roof rafters for mounting the solar collector panels and their installation satisfies the structural roof framing design load requirements of the Residential Code of New York State. I have reviewed and certify that the manufacturer's guidelines and equipment for the photovoltaic equipment for the above residence meet the requirements for wind and snow load and that the roof structure is adequate to carry the new loads imposed by the System. For the installation of the solar mounting, the rails are securely anchored to the rafters utilizing lag screws that have been designed for wind speed criteria of 120 mph Exposure C and snow ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and geo design criteria are not applicable to this solar installation. The solar collector system and the mounting assemblies comply with the applicable sections of the Residential Code of New York State-"Solar Systems" and loading requirements of roof-mounted collectors and the minimum requirements for buildings and structures of ASCE 7-05. This system has been generally observed to be installed properly at the above referenced residence. The installation is in accordance with the minimum requirements certified by this letter. I hope that this letter serves and meets with the approval of the Building Department. ���� N�w r� Sincerely, y,`� . e �, ��� � � �' William G. Fish� ev�, .E. 1 Licensed Professional En 'neer r � � �� Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Constiuction Fstimates/Oversight•Expediting•Inspections FI�LD I�SP��CD�7��O�x �AA� � F CO�,N�u� ' ' , , . , i • , , , . _ �t�s I �� ����,A�O�{XS� , . , . , , � , � - - -..,...._..,....:_.-,..._..._�.. ' , , , � , , . � ' ' ' � ' � �'OYJND�TT4N(2NI)) . ' � � ., . � , . • � � z . , , , � . o , , � � � . ' �" y ; , • , , , , , � ROU�x��xcr& � . . � . � � . � , .� . � PLUMBSN'G ,�,.- �� •, . ' . .� • , • ,' . . , , •�, � ��• .,_;_. , ',, . ,. ; , . . , ' ' ' �! � . � ' � TNS�LATZON PE1�N��'� • � , • . � STATE EI�ER.GY�45�� , , � , , , .. , . , , . , . , „ , , , . . . , , ' i ' , � , ' � � � � ' • ' , , FZj•IAL , ' • ' i • . . � , � , • , . , .; , . , •• � � , , , . ., , , _ � • . ,, . . • • � ��I T5 � C� , ��; .. ,. � � , � � ' .; � . � , � .� ' ' ' . i . ., . , , , ' 1 1 , �� o � ���-✓Q� ' s , �� �'� � ` �. ;, . � �.�,�. . . � z � ' • � . m ' � � e��J ��.WN � R � , . , � • � � � � , '. � � • \ ( � I � � � , I I • , • � � � , . ' • � • • ' �� � , , • . • . � � . � � ' • . . , • � ' � ` " ICN � � � I � � � � ' . � . ' • � �� 1 � i � � � ' • � � �� , . , �, . , ' . a ,,, � , � . . , , � . . , . , , . . . ; . . , TOWN OF SOUTHOLD BUILDING PERIvIIT APPLICATION CHECKLIST BUILD[NG DEPARTMENT Do you have or need the,following,before applying?• TOWN HALL � Board,ofHellth SOUTHOLD,Nl''11971 �4'sets of Building Plans TEL:(631)765-1802 Plannmg Board approval TAX:(631)765-9502 ��/ �urvey SoutholdTo�vn.NorthFork.net PCRMIT NO. `"/d��a� Check • 5eptic Fonn � � N.Y.S.D.E.C. �J�,,,� n� \ Trustees ("�7 I� \�// �C.O.Application 1� �� V D Flood Peimit Ezamined 0 � �'� Single&Separate ,Stonn-Water Assessment-Fonn ,I/� �p�Y 2 0 ���� Contuct: Approved �� `,1U M811 t0:SUNahon Solar Systems,Inc Disapproved a/c ��� 177 Remington Boulevard,Ronkonkoma NY 11779 o�S�r� • D PhortC:�631)750-9454 1 ,211�' {J laa Expiration _ , � � ilding Inspe' or • APPLICATION FOR BUILD,IN,G,P IT Date� ' �� ,20 INSTRUCTIONS� 'a.�This application,MUS"I'be completely'filied in by typewriter or in ink and submitted to the Building Inspector with 4 sets of.plans,,accurate plot plan to scale.Fee according to'schedule. b.Plot plan�showing location of lot and of buildmgs on premises,relationship to adjoining premises or public streets or areas,,and waterways. a The work covered by this applicarion may not be commenced before.issuance,of Building Permit. � d..Upon.approval of this application,the Building Inspector'will issue a Building Permit to the.applicant.Such a permit slialt be kept on the premises available for inspection throughout the work. e.No buililing shall be occupied or used in whole or in,part for any purpose what so ever until�the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work�authorized has not commenced within 12�months after the date of issuance or'has not been completed within 18 months from such date.If no zoning amendments or other cegulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extensiomof the pemut for an addition six months.Thereafter,�a new'pemtit shall be requiced. � ` APPT,ICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the � Building Zone Ordinance of tlte Town of Southold,SuffolkCounry,New York,and other applicable Laws,Ordinances or. Regulations,for'the constiuction of buildings,additions,or alterations or for-removal ordemolition�as herein described.The applicant agrees to comply with all applicable'laws,ordinances,,building code,housing code„and regulations,and to•admit ,authorized inspectors on premises and in building for necessary inspections. , (Signature of applicant or nnme,if a corporation) f SUNahon Sotar Systems,inc 171 Remington Boulevard,Ronkonkoma NY 17779 {Mailing acidress ofapplicant)� State whether applicant is owner,lessee,agent;architect,engineer,general contractor,electrician,'plumUer�or-builder SUNahon Solar Systems,Inc-Conhactor Name of owner of premises Grace Mc Donough ---- -- ------------------ --- -- --------- --=. _ ___ - --• • --- --— --- --—- - -- �- -"---, (As on the tax�roll o"r lateshdeed) � '- ��- �- If appiicant is a corporation,signature of duly authorized officer Scott Maskin-President _ (Name and titl'e of corporate officer) Builders License No.4aioa-H � Plumbers License No. NiA Etectricians License No.saa�2-Me ' Other Trade's I.icense No. i. Location of land on which proposed work will be done: 4995 Sound Avenue Mattituck House Number Street Hamlet , County Tax Map No. 1000 Section izi � ' x Block � Lot 3 3 , . � , . � , - � , , . _ ''; , , , Subdivision Filed Map No. Lot , 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing usc and occupancy Residence , b. Intended use and occupancy Residence witn addition of solar Panels 3. Nature of tivork(check which applicable):New Building Addition�_Alterafion_� Repair Removal�ei"nybl�"io�?$ ��r�a� �Ox�iec. ork��a,Pe�e�s E ' � ��' �.r��g `~'� ,�.? =_a's�>�,��w� � (Description) 4. Estimated Cost $z�,o�s oo ee $zoo�.vo-•-`'� � ��., � �•� ,, (To�bep�i�j'on filing this application) 5. If dwelling,number of dwelting units �� I�( ker�f�we��in�unit��on ea�ch floor if garage,number of cars ���� �� a `"� ""� 6. If business,commercial or mixed occupancy,spe�i�.���tu�c�nd ex�t�e�qnt oQf each type of use. e� i.t.�Yi }�����1..�4d 7. Dimensions of existing structures,if any:Fro�it�-�`��'x�'���.a�'..�'��'�;'a`;R`R��i',�>'�`�� Depth Height Number of Stories � �— , Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height - Number of Stories 9. Size of lot:Front Rear Depth 10:Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12.Does proposed construction violate any•zoning law,ordinance or regulation7 YES_NO X 13.Will lot,be re-graded?YES NO x Will excess fi116e removed from premises?YES_NO x 14.Names of Owner of premises crace nnc oonou9n Address4995�°^'"°e^°e,^"a'°�,�""„'Sz phone No. (ss�)ss�-a5os Name of Architect w�mam c F�Sne� AddTeSS PO Box30,Oakdale,NY 11769 Phone No ss�aas-aa�s NameofContractor SUNa��o�so�a�sYs�ems,��� Address �»RemingfonBaulevard,RonkonkomaNYphoneNo. ss�aso-saea 15 a.Is this prnperty within 100 feet of a tidal wetland or a freshwater wetland?*YES NO X , *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300'feet of a tidal wetland?*YES NO x *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 1G.Provide suryey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO X *IF YES,PROV(DE A COPY. STATE OF NEW YORK) � SS: COUNTY OF ) - - --- - --- - - - - - - - - - - ' l � 8cott Maskin-President-SUNation Solar Systems,Inc fieing duly sworn,deposes and says that(s)Ite is the applicant (Name of individual signing contract)above named, (S)He is tfle Contractor , (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perfomi or have perfomied the said work and to make and file th�s apphcation; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. •Sworn to before me this S�_day of 20 <<P �-' . �. . � Notary Public LYNN VITA Signature of Applicant , Notary Public, State of NewYork R2gistration #01 V15068399 Qualified in Suffolk County My Commission Expires Oct. 2s, 20!$ Scott A. Russell � ,��°S�F��� � �'7C'�0�][�.l��l[\'�VA\'7C']E]�. SUPERVISOR . �$ � I��1[A\I�A\�G�]EI��1[]E�'7C' SOLITHOLD TOWN HALL-P.O.Box 1179 � � 53095 Main Road-SOUTHOLD,NEW YORK 11971 Z'own of So u th o l d �o� ���� CHAPTER 236 - STOI�MVVATEIZ MANt�GEMEIv'T WORY� SI�EET (TO BE COMPLETED BY THE APPLICANT ) ��� �'��� ������ �Y���t,� � �� ��� ���,����: Y85 I�IO fCHECIi ALL THAT APPLY) ❑ax A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square f eet of ground surf ace. ❑� B. Excavation or f illing involving more than 200 cubic yards of material within any parcel or any eontiguous area. ❑OX C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑�x D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑�x E. Site preparation within the one-hundred-�ear f loodplain as depicted on FIRM IVIap of any watercourse. ❑� F. Installation of new or resurfaced impervious sua�faces of 1;000 square � feet or more, unless prior approval of a Stormwater 1V[anagement Control Plan �vas received by the Tovvn and the proposal includes in-kind replacement of impervious surfaces. � If you ans�vered NO to sll mf the questions above, STOP! Complete the Applicant section belo�v wiW your Name, Signat�ate, Contact Informa�ion, Date 8 County Tax Map Number! Cd�apter 23s does not apply to your project. If you ans�vered YES to o�e or more of the above, please submit Tr�a copies of a Storffiwater DZanagement Control Plan and a completed Check List�'orm to the Building Department Evith your�uilding Permit Appincation. APPUCA[VT: (Property O�cner.Dnign Profe�sional,A�en, ontracror,O her) S.C.T.M. '�: 1000 Date Distrcct N�1e� Scott Maskin-SUNation Solar Systems, Inc. 121 �_ �� J'o2Q'—��O n �t� Section Block Lot c�`�—l% '�—""`' ****,FOR BUILDING DEPARTNIENT USE ONLY**** Contacbinformation (631) 750-9454 R�M v�m� Revie��red By: ,� — — — — — — — — — — — — — — — — , �Date: "�J"oZl7—��s ; Propei•ty Address/Location of Construction Work: — — — — — — — — — — — — — — — — — ' 4995 Sound Avenue App�o�red for processing Building Permit. i Storm���ater Management Control Plan Not Required. MattltuCk, NY 11952 Stormwater Management Control Plan is Required. � tFor��ard to Engineeruig De�a�•tment for Review.) � FORM � SMCP-TOS MAY 2014 � • : , ! ��o�se�ryo ! . ao �o ; Town Fiall Annex � Telephone(631y 765-1802 i• 54375 Main Road � gQ ' ' P.O.Box IE79 � Q roqer.riche�t(a�town s0U�h01�.I11/t!S i Southold,NY l 1971-0959 '� � �� � �. �����4U(Vt'1,�� � � � , BUILD�tG DEYARTMENT i . TOWN OF SOUTi�OLD � APP�iCATlON FOR ELECTRlCAL 1NSPECTi4N I � _ • - . ;= � REQUES"fED BY: Lynn ° Date: 6-24-16 i Compa�y Name: SUNation Solar Systems Inc. - E. I , N�m�� Scott Maskin � f� � - r License No.: 33412-ME . � I Address: 171 Remington Blvd. Ronkonkoma, NY 11779 - � � ' Phone No.: 631-750-9454 � �-- . � JOBSlTE fNFORMATI4N: (*indicates req"uired information) i *Name: Grace McDonough - � � � "Address: 4995 Sound Avenue, Mattituck, NY 11952 � j *CKoss Street: ' � ' ' � I fPhone No.: 631-697-8508 � i ; Permit No.: 40732 � � � Tax�Map Districf: 9400 , Section: 121 � B(ock: 1 Lot:_ 3.3 � � � *BRIEF DESCRIPTION OF WORK(Please Print Cleariy) � 5,670 Watt solar system. � ; � 18-LG315NiC-G4 PV Modules. 1-Solaredge SE5000A-US inverter. _ � - - . � . - - i tPiease Circle All That Appiy} � i l *Is job ready for inspec�ian: � YES�,N� Raugh In Final *Do you need a Ternp Certificate: YES! NO - � - ' Temp InformatBon(If�needed� � � � �Service Size: 9 Phase 3Phase 100 150 200 30Q 350 4QQ Other *New Servlce: R�-connect Underground Number of Meters Change of Service Overhead . Add'+tiona! Informafion: � PAYMENT DUE WlTH APPLICATION � �' � �. , . . �S`-f.��. 82-[�equest for Inspecfion Fotm � � I ���OF SO!/r�„o� a o Town Hall Annex � � Telephone(631)765-1802 54375 Main Road FaJc(631)765-9502 P.O.Box 1179 G • Q Southold,NY 11971-0959 �Q a l'�COUNTY,�� July 22, 2016 BUII,DING DEPARTMENT TOWN OF SOUTHOLD SUNation Solar Systems 171 Remington Blvd Ronkonkoma NY 11779 Re: McDonough, 4995 Sound Ave, Mattituck TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy. NOTE: Certification needed from an architect or engineer stating the panels were installed to the roof per NYS Building Code Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of$50.00. � Final Health Department Approval. P�UCTIb@I"S SOId@C' C@P'tlf Cate. (All permits involving plumbing after 4J1/84) Trustees Certificate of Compliance. �Town Trustees#7ss-�ssz� Final Planning Board Approval. (P�anniny#7ss-1938) Final Fire Inspection from Fire Marshall. � Final Landmark Presenration approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT — 40732 - Solar Panels � New York State Insurance Fund Workers'Compensation&Disability Benefits Specialists Since 1914 199 CHURCH STREET,NEW YORK,N.Y. 10007-1100 Phone (888)997-3863 CERTIFICATE OF WORKERS' COMPENSATION INSURANCE ^^^^^^ 753118816 SUNATION ROOFING SERVICES INC 171 REMINGTON BOULEVARD RONKONKOMA NY 11779 POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER PERIOD COVERED BY THIS CERTIFICATE DATE � Z2160 670-2 167534 01/01/2016 TO 01/01/2017 3/24/2016 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO.2160 670-2 UNTIL 01/01/2017, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF SAID POLICY IS CANCELLED,OR CHANGED PRIOR TO 01/01/2017 IN SUCH MANNER AS TO AFFECT THIS CERTIFICATE, 10 DAYS WRITTEN NOTICE OF SUCH CANCELLATION WILL BE GIVEN TO THE CERTIFICATE HOLDER ABOVE. NOTICE BY REGULAR MAIL SO ADDRESSED SHALL BE SUFFICIENT COMPLIANCE WITH THIS PROVISION. THE NEW YORK STATE INSURANCE FUND DOES NOT ASSUME ANY LIABILITY IN THE EVENT OF FAILURE TO GIVE SUCH NOTICE. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND . �� � � DIRECTOR,INSURANCE FUND UNDERWRITING This certificate can be validated on our web site at https://www.nysif.com/cert/certval.asp or by calling(888)875-5790 VALIDATION NUMBER: 638807274 i_�a a ReceiptCopy Page 3 of 3 - ���� ; � � � �1 , _ ;� ,��,��� SIJFFOLK COUNTY DEPT OF LABOR, LICENSING & CONSUMER AFFAIRS PAYMENT RECEIPT RECEIPT NO. 300762• SUNATION SOLAR SYSTEMS INC 1217 MONTAUK HIGHWAY OAKDALE NY 11769 Rec'd From: D/BIA: Date: S MASKIN SUNATION SOLAR SYSTEMS INC 5/13/2015 Payment Type: No: � Drawn On: CHECK 11033 EMPIRE NATIONAL BANK Category Service Fee Violation Slip No Remarks 1 -Electrician, Master C-Lic. Renew. $400.00 -- ----_-_.�— l��� �' , SUFFOLK COUNTY DEPT OF LABOR, s� UCENSING&CONSUMER AFFAIRS ' ,,��� �` `� MASTER �.= ,�' _ ELECTRICIAN .��' NAeE� _ ` � ��'�� SCOTTA MASKIN t�,� .'� This certiftes that the B�ESSNAYE bearer is duly SUNATION SOLAR SYSTEMS INC � licensed tiy the County of Suffolk "`°°'°"'°°°°' �� .� 33412-ME os�2arzoos rT�aa.��t.�/rCr` co�.ti,roo« owannw w� �6/���2��� REC'D BY: License#/Regist�ation#: KR 3412 OTAL: Remarks: $400.00 Customer copy / • - SUFFOLK COUNTY DEPT OF LABOR, '� LICENSING 8 CONSUMER AFFAIRS i �.� � �ti HOME IMPROVEMENT ; � ,;m'� , CONTRACTOR � • LICE SE � '�, SCOTT A MASKIN BUSNESSNAAIE � This certifies that the SUNATION SOLAR SYSTEMS INC , bearer is iluty licensed bythe u«m,�,,,,,,,, - ,�,,,,��, r County of Suffolk 03f06i2008 4_41'04-H � ' ��""���"���` °`rs�''naa°"T= 03/01/2018 Cammlasbna� Fisher Engineering Services, P.C. PO Box 30 • Oakdale •New York 11769 Phone: (631) 563-9028 May 16, 2016 Attention: Building Department Subject: Engineer Statement for Solar Roof Installation McDonough Residence-4995 Sound Avenue, Mattituck,NY 11952 I have verified the adequacy and structural integrity of the existing roof rafters for mounting the solar collector panels and their installation satisfies the structural roof framing design load requirements of the Residential Code of New York State. , � I have reviewed and certify that the manufacturer's guidelines and equipment for the photovoltaic equipment for the above residence meet the requirements for wind and snow load and that the roof structure is adequate to carry the new loads imposed by the System. For the installation of the solar mounting, the rails shall be securely anchored to the rafters utilizing lag screws that have been designed for wind speed criteria of 120 mph Exposure C and snow ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and geo design criteria are not applicable to this solar installation. The solar collector system and the mounting assemblies comply with the applicable sections of the Residential Code of New York State- "Solar Systems" and loading requirements of roof-mounted collectors. The proposed solar collector system and the mounting assemblies comply with the applicable sections of the Residential Code of New York State- "Solar Systems" and loading requirements of roof-mounted collectors-2010 and the minimum requirements for buildings and structures of ASCE 7-05. The installation shall be in accordance with the minimum requirements certified by this letter. The existing roof rafters are 4"x6" on 28" c.c., with an actual span of 12'-5.5", with 1"x2" collar ties , plywood roof decking and one roof shingle layer on the house as shown � on the drawings. There are no structural modifications planned or required for the existing roof. I hope that this letter serves and meets with the approval of the Building Department. Sincerely, ��pF NEW r0 �j�..��� - � �.�., y�r ,' ! �� � � 3� William G. Fisher, P.E. � , , Licensed Professional Engineer �. � � � � �'$, p7s�b� � Archttectural Design•Residenhal•L�ght Commercial A � Add�t�ons•Extensions•Conversions j� Construction Estimates/Oversight•Expedihng•LlspecUons LG � . . . . � . Life's Good � � . ■ �------- �-�------ ----�.�-�_ ---�tt-��_ '1--.--.��� ' '�---.��.��� - , LG f\IeOi\I�2 � - � � - � - LG's new module,NeONT"'2,adopts Cello technology Cello technology replaces 3 busbars with 12 thin wires to enhance I. APPROVED PRODUCi Ipower output and reliabdity NeONT"'2 demonstrates LG's pVE �� E1Y os � 60 C�l` efforts to mcrease customer's values beyond efficiency It � �ry Intertek � features enhanced warranty,durabdity,performance under IQN564573 BSEN61215 real environment,and aesthetic design surtable for roofs PharovalraicModules �� . Enhanced Performance Warranty •• High Power Output LG NeONT""2 has an enhanced performance warranty � ' Compared with previous models,the LG NeONT""2 The annuaf degradation has fallen from-0 7%/yr to has been designed to significantly enhance its output -0 6%/yr Even after 25 years,the ceff guarantees 2 4%p effiaency,thereby making it effiaent even m limited space more output than the previous NeONT"'modules �� �, Aesthetic Roof O Outstanding Durability - LG NeONT"'2 has been designed with aesthetics�n mind, With its newly reinforced frame design,LG has extended thinner wires that appear all bfack at a distance The the warranty of the NeONT""2 for an additionaf 2 years product may increase the value of�a property with its �Additionally,LG NeONT""2 can endure a front load up to � modern design 6000 Pa,and a rear load up to 5400 Pa � � � � \\ ••• Better Performance on a Sunny Day � Double-Sided Cell Structure , � • � LG NeONTM'2 now performs better on sunny days thanks The rear of the cell used in LG NeONT"^2 will contnbute to to its improved temperature coeffiaency generation,�ust hke the front,the light beam reFlected firom the rear of the module is reabsorbed to generate a great ' l amount of additional power � About LG Electronics LG Elettronits is a global player who has been committed to expanding its capaaty,based on solar energy business as its future growth engine We embarked on a solar energy source research program in 1985,supported by LG Group's rich experience in semi-conductor,LCD,chemistry,and materials industry We successfully released the first Mono X°series to the market in 2010,which were exported to 32 countries in the following 2 years,thereafter In 2013,NeON'""(prewously known as Mono X�NeON)won"Intersolar Award';which proved LG is the leader of innovation in the industry � a ��� � , A I 0 i ' Mechanical Properties Electrical Properties(STC*) Cells 6 x 10 3z0 W 31 S W 310 W 305 W Cell Vendor ' LG MPP Voltage(Vmpp) 33 6 33 2 32 8 32 5 Cell Type Monocrystalline/N-type MPP Current(Impp) 9 53 9 50 9 45 9 39 Cell Dimensions 156 75 x 156 75 mm/6 x 6 inch Open Circwt Voltage(Voc) 40 9 40 6 40 4 40 1 �r of Busbar 12(Multi Wire Busbar)� Short Circuit Current(Isc) 10 OS 10 02 9 96 9 93 Dimensions(L x W x H) 1640 x 1000 x 40 mm Module Effiaency(%) 19 5 19 2 18 9 18 6 64 57 x 39 37 x 1 57 inch Operating Temperature(°C) -40-+90 Front Load 6000 Pa/125 psf� Maximum System Voltage(V) 1000 Rear Load 5400 Pa/113 psf� Maximum Series Fuse Rating(A) 20 Weight 17 0±0 5 kg/37 48 t 1 1 lbs Power Tolerance(%) 0-+3 ConnectOf TyPE MC4,MC4 Compatible,IP67 *STC(StandardTestConditian)Irradiance 7000 W/m',ModuleTemperature 25°C,AM 1 5 Junction Box IP67 wrth 3 Bypass Diodes 'The nameplate power ou[put is measured and determined by LG Elecirama at rts sole and absalute discretion `The Typicaf change in module effiaency at 200 W/m'm relanon to 1000 W/m'is-2 0% Length of Cables 2 x 1000 mm/2 x 39 37 inch Glass HighTransmissionTemperedGlass Electrical Properties(NOCT*� . Frame Anodized Aluminum 320 W 315 W 310 W 305 W Certifications and Warranty Maximum Power(Pmpp) 234 230 226 223 MPP Voltage(Vmpp) 30 7 30 4 30 0 29 7 Certifications(In Progress) IEC 61215,IEC 61730-1/-2,UL 1703, MPP Current(Impp) 7 60 7 58 7 54 7 49 ISO 9001,IEC 62716(Ammonia Test), Open Circwt Voltage(Voc) 37 9 37 6 37 4 37 1 IEC 61701(Salt Mist Corrosion Test) Short Circwt Current(Isc) 8 10 8 08 8 03 8 O1 Module Fire Performance Type 2(UL 1703) •NOCT(Nominal Operatmg CeIlTemperature)Irradiance 800 W/m2,ambient temperamre 20�C,wind speed 1 m/s Product Warranty 12 years� Output warranty of Pmax Linear warranty'�t Dimensions(mm/in) (measurement Tolerance±3%) ,oam34 ,00ie39 *1)1 st year 98%,2)After 2nd year 0 6%p annual degradatwn,3)83 6%for 25 years ' Temperature Coefficients , - NOCT 46 t 3°C o,� „�6 � Pmpp -038%/°C� .� � a�,aoos �/OC -�Z8���C o=e,nx oewiv or.anz evazrta� sno.�vaeoa� ISC 0 03%/°C 000,,,,, �� �$.e„��.,,a„ o...na�..w..,'s Characteristic Curves , „.�, ���_��°•�°'�mw°°�s°°�•, o,.��°;°�::;� s ,000w ..,000 � � � BOOW c,o��e��sn i.,l+:.,l 1.I H) = 800 �.wl 600W 600 rtia� u��.(e.,l 4� 400W y / � 200W � uei..cm 200 �.. '_s' ""._. e ' E � Val�a9e(V) `' a '§ m a r a 000 500 1000 1500 2000 2500 3000 3500 9000 4500 � a� a � � E y_ '� _ � 1� � � 120 "`-�-�_. ` _"_ _ _ _ Isc ' 100 ` !"� '" "'Voc _ 'v'�—�,..� � BO " __ ' " ' _" _'"" ' ' '_' " Pmax 6p ' _' ""' "_ ' ' "' _" "__ � " _ __ ' '" " '_ "_ ' __ _ _" _ 20 _ ' _ _ _ ' "_ 0 TemPera�urel�C) ` - - - " -0o zs o 2s w �s 50 *The dis[ance hetween the<enter of the mounnng/gmunding holes - L� North Amen�a Solar Business Team Product specfications are sub�ect to change withou[notice ��� LG ElectronicsUSA Inc DS-N2-60-C-G-F-EN-50427 Lifes Good 1000 Sylvan Ave,Englewood Cliffs,N107632 Copyright�O 201 S LG Electromcs All rights reserved Innovation for a Better Life • Contact Igsolar@Igecom Ot/04/2015 P www Igsolarusa com � �d.i . solar - • • :� � • SolarEdge Single Phase Inverters . For IVorth America � SE3000A-US/SE3800A-US/ SE5000A-US/ SE6000A-US/ _ SE7600A-US/SE10000A-US/SE11400A-US �f-`��,. - ----- �---'°�----�-`s��n 0►`=e�;w. – - ---- .____� x;��2.25 '< , � y� Y m �ti�v e a0� i ',�g WaR ��✓.` j - ._ .__'_,�','+a e n��r, � 'i�u.,�r��*''''' } _ . . _ a � ;`�! j _ _-_—_ - -- -----_'.'; � � �; , , � - -- - - - - - '� -; o � - - -,---- ------4' i �- ! � -:�--- - -- -- ; i . � --..._. �_�_.._l , ' y� a �__��J .. I '� � ' ' . i. ��'y ' �� � ' . lP,-� ` - ------ ; -- �',�� The best choice for SolarEdge enabled systems — Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance(part numbers ending in"-U") ° — Superior efficiency(98%) — Small,lightweight and easy to install on provided bracket � Built-in module-level monitoring � Internet connection through Ethernet or Wireless ° . - _ • — Outdoor and indoor installation � . . , — Fixed voltage inverter,DC/AC conversion only . — Pre-assembled AC/DC Safety Switch for faster installation ` USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us I �D I a r p Q Q � SII1gIG PI11S@ II1Vet'��1"S for North America SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ SE7600A-US/SE10000A-US/SE11400A-US ' SE3000A-US SE3800A-US SESOOOA US SE6000A-US SE760QA-US SE1(f000A-US SE11400A-US �OUTPUT - ' Nominal AC Power Output 3300 3840 5200 @ 208V 60�0 7680 9980 @ ZQ$� 11520 VA 5520 @240V 10080 @240V ................ .......................... ................ ............... . . ........ .................. .................. ........... Max.AC Power Output 3650 4150 5600 @ 208V 6000 8350 10800 @ 208V 12000 VA 6000 @240V 10950 @240V ..................................................... ............... ................. ..... .......... ................ ............... AC Output Voltage Min-Nom-Max* � � � 183-208-229 Vac .j................ ...... . ....................................... � ....... ................. ................ ................ .................. .................. ........... AC Output Voltage Min.-Nom-Max* � f � � � ✓ � 211-240-264 Vac ............................ .............. ................ ............... ................. ................ ................ .................. .................. ......... . AC Frequency Min-Nom-Max* 59.3-60-60.5(with HI countrY setting 57-60-60.5� Hz ................. . ................ . .......... . . . . ........... Max Cont�nuous Output Current...... ......14.......1......16......I..23.@.240V..I.......ZS.......1......32..... .1...42 @ 240V...1... ....48. ...... ....A..... GFDI 1 A .................................. .......................................................................................................................... ........... Ut�lity Monitoring,Isianding Protect�on,Country Configurable Yes Thresholds � INPUT • � Recommended Max.dC Power'�� q100 1 4800 6500 7500 9600 I 12400 14400 W (STC) .................................. ....... ........ .............. ................. ................ ................1 .. .............. .................. ........... Transformer-less,Ungrounded Yes ........................................ .. ........................................................ . ........................................................... ........... Max Input Voltage 500 Vdc ........................................... ................................................. .............................................. ......................... ........... Nom DC Input Voltage......... ....... ................ 17 ...325 @ 208V/350 @ 240V.... .... ........ ......... .... ...Vdc.... 17 @ 208V 33 @ 208V ...... Max Input Current*'�* 11 13 18 23 5 35 Adc @ 240V 30 5 @ 240V ....................................... ................ ............... ................. ................ ................ ........ .................. ........... Max.Input Short Circwt Current 30 45 Adc .................................... ...... ............... . ................................ ........................................ ............. . . ... Reverse-Polarity Protect�on , ,Yes ........................................... .......................... ........................................................... ........... Ground-Fault Isolat�on Detect�on 600ks:Sensit�vity ........................................... ................i............... ............. .............. .................. .................. ........... Maximum Inverter Efficiency 97.7 98 2 98 3 98 3 98 98 98 % ..................................... .. .. ................ ............... ................. ........ ....... ................ .................. .................. ........... 97.5 @ 208V 97 @ z08V CEC Weighted Effiaency 97 5 98 97 5 97 5 97.5 % i 98 @,240V.. ................ ................ ..975 @ 240V.. ................ ....................................... ............... ............... ........ .. ....... .. NightfimePowerConsumpt�on <25 <4 ! W ADDITIONAL FEATURES ° Supported Communicat�on Interfaces R5485,RS232,Ethernet,Z�gBee{opt�onal) ;STANDARD COMPLlANCE � Safety . . .... .UL1741,UL16998(Part numbers ending in°:U'.J,UL1998,CSA 22.2 . ............................ . ......................................... ........... Grid Connection Standards IEEE1547 ........................................... ...................................................... p ....................................... ................... ........... Emissions FCC art15 class B , INSTALLATION SPECIFICATIOIUS AC output conduit size/AWG range 3/4"minimum/24-6 AWG 3/4"minimum/8-3 AWG .......................... ........................................... ..... .......................................... ........... ........... ....... DC input condwt size/#of strings/ 3/4"minimum/1-2 strings/24-6 AW6 3/4"minimum/1-2 strings/14-6 AWG AWGrange.............. ...... ..................................................... ........... Dimensions with AC/DC Safety 30 5 x 12 5 x 7/ 30 5 x 12 5 x 7.5/ in/ 30.Sx12.5x105/775x315x260 Switch(HxWxD)..................... .. .......775 x 315 x 172....... ........775 x 315 x 191......... . mm.... .... ............... ...................... , ................... ........ ..... . Weight with AC/DC Safety Switch 51.2/23 2 54 7/24 7 88:4/40 1 Ib/kg .... ................................ .............. . . ........... ............... . ....................... . Cooling Natural Convect�on Fans(user replaceable) .................. ........................ . <.25............................... .............................,........................ Noise <50 dBA ........................................... .................................................................. ...................................................... . ......... , Min-Max.Operat�ng Temperature -13 to+140/ 25 to+60(CAN version**** 40 to+60) °F/°C Ran�e..................... .............. ..................................... ..............................................•••................................... ........... Protect�on Rat�ng NEMA 3R ........................................... ........... .................. ..... . "For other regional settmgs please contact SolarEdge support "'Limrted to 125%for locahons where the yearly ave2ge h�gh tempeiaWre fs above 77°P/25°C and to 135%for loca4ons where it Is below77°F/25°C For detaded mformat�on,refer to http!lwwwsolaredpe us/files/pdfslmverter dc ovemm�e ewde odf "*'A higher current source may he used,the mverter wdl hniit rts mput current to the values stated ""CAN P/Ns are ehgible forthe Ontano FlTand microFlT(m¢roFIT exc SE11400A-US-CAN) � 8 ; ° -° � �. ; �. -; � -���~�r/'"���� ����� � '`�su�s��c � � ,-��,,,_. i �~ --a,�,aR�s— i� 4 '� `.;�=���p 50LAR SYSTEMS ` ; �� r.�,, �-�., �. �` ;� �"/°���' Powerrng your woNd .� i 631-750-9454 t O - e 0 • 6 � 0• p• 0 •• 0 . ' - ° �`�� www.sunationsolarsystems.com �e.o •.. � Q•: �°o- A { 'e,,rr� .'�.� ''�': �'. ;�e ,{' ; �.C, �.� - L_r..a��. ��-"^��� r ._�, . , � .,�-�: ,� � solar �-� . . s.�a � � o 'Q _� � ��� ����� r� � � -�; '�� � i� ' i! �I ,� h SolarEdge Pov�►er Optimizer IVlodule Add-On For North America �������V / �P3���NV�V / �������V / �P4����V � _ . • � .� -',`•,m.•'f,.i�1, . 3����e�� •� _ ' ����TB��' �r' .�v •���`f � s�i�p� �� , 5�3. ���'��� , �e ( � � 4 PV povuer optimization at the module-level ; i � Up to 25%more energy j , � Superior efficiency(99.5%) ; � Mitigates all types of module mismatch losses,from manufacturing tolerance to parfial shading � � � Flexible system design for maximum space utilization � I m Next generation maintenance with module-level monitoring ' , � � Module-level voltage shutdown for installer and firefighter safety � USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us s�o I a r � • • � SolarEdge Power Optimizer Module Add-On for North America OP250-LV/ OP300-MV/ OP400-MV/ OP400-EV ' � � • ° - OP250-U! OP300-MV OP400-MV � .OP400-EV � ' INPUT . ; . - . , , . , ., � , � ! Rated Input DC Power* 250 300 400 400 W ......................................................................... ..................... ..................... ..................... ..................... ............. Absolute Maximum Input Voltage(Voc) 55 75 75 125 Vdc .......................................................................... ..................... ..................... ..................... ..................... ............. MPPT Operating Range 5-55 5=75 5-75 15-125 Vdc ......................................................................... ..................... ..................... ..................... ..................... ............. Maximum Short Circuit Current(Isc)of connected PV 10 10 10 7 Adc Module .........................................................:............... ..................... . ........ ........ ..................... ..................... ............. Maximum DC Input Current 12.5 12.5 12.5 ,8.75 Adc .................... ..................... ..................... ..................... .....o....... Maximum Efficiency 99.5 /o ......................................................................... ....................................................................................... ............. Weighted Efficiency 98.8 % ......................................................................... ....................................................................................... ............. Overvoltage Category II , OtlTPUT DURII�G OPERATION{pOWER OPTIMiZER:CONNECTED TO OPERATIiVG Ii�VERTERj � � ' � ` ` Maximum Output Current 15 Adc ..................................................................... .......................................... ............................................ ............. Operating Output Voltage 5 60 Vdc },OUTPUT DU,RING STANDBY(POWER OPTIfV11ZER.DISCONiVE,CTED FRt3M INVERTER OReINVERTER OFF) � � ` Safety Output Voltage per Power Optimizer 1 Vdc 'STANDARD COMPLIANCE � ' � � • - ` ' • � � EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 ......................................................................... ....................................................................................... ............. Safety IEC62109-1(class II safety),UL1741 ......................................................................... ....................................`.....j;........................................... ............. Material UL-94 5-VA UV Resistant ......................................................................... ....................................................................................... . ........... RoHS Yes INSTALLATION SPECIFICATlONS " ` ° . „ ° ° - `� . ` , ` � � Maximum Allowed System Voltage 1000 Vdc ......................................................................... ....................................................................................... ............. Dimensions(WxLxH) � 143x210x45/5.63x8.26x1.75 mm/in ......................................................................... ....................................................................................... ............. Weight 450/1.0 gr/Ib ......................................................................... ....................................................................................... ............. Input Connector MC4/Tyco/H+5/Amphenol—H4 ......................................................................... ....................................................................................... ............. Output Wire Type Double insulated;6mmz;MC4 .............................................:........................... ..................... . . . .. . . . ............. ... .. Output Wire Length . 0:95/3 0 � 0.95/3.0 � 1.2/3.9 1.6/5,25 m/ft ................................................................. ...... .................... .................... ......... . . . . ... Operating Temperature Range -40-+65/-40-+150 °C/"F ......................................................................... ....................................................................................... ............. Protecnon Rat�ng IP65/NEMA4 ......................y................................................. ........................................._.................................. .......... .....0....... Relat�ve Humidit 0 100 /o *Rated STC power of the module Module 6f up to+5%powertolerance allowed ; PV,SYSTEM DESIGN USING A SOLAREDGE ��� g�NGLE PHASE �THREE PH,ASE"208V TNREE PHASE 480V � ; INVERTER . ` -� ° - ' ' " . • � ' �' ; Minimum String Length(Power Optimizers) 8 8 18 ' ......................................................................... .............................. .......................:...... .............................. .......... Maximum String Length(Pawer Optimizers) � 25 25 50 ......................................................................... .............................. .............................. .. ... . . . .. Maximum Power per String 5250 6000 12750 W .................g....................�............................... .............................. ............ ........... .. . ... . . Paralle{Strin s of Different Len hs or Orientations Yes �_...a.-.....�-m�. . . a, �� r .. ~ e e ,. � n.—�..._. , --,s.m-,_�-.-�.a..._....... ,..... .�_...v.. .,. .. ^S a �)` � t�+{'�j4 6i��//.���� !� t �• ���.����� t � ;��,,�� SOLAR SYSTEMS � ° �'�s Powering your worid �' - 1217 Montauk Highway,Oakdale,NY 11769 = cy �a•- • • �. .�� o• � : e e 631-750-9454 �,� r "a ♦. �."• ��• • . ' . ' . _ o- -.' ' �.'- �. � � .- . .' p www.sunat�onsolarsystems.com �� �.._.0 • • • • � � • . • . • s • • • • The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical ; innovations have been proven to drive ;-- : - . W___ ___._ _- -___� __ -__ --, ��.� _ down costs and improve installation c� � � �- - �_.: r%'s ��.r quality on more than 350 MW of solar ��--=��/�/--,�-r'��='-� =-�=--�-`'� ,r�����:��;��.�;� -F��y �� �� .f/ �v�Dt:�3i`�j'M1Nd1.:s!:1}JQ`.�l�a installations. 'y ��� .;fu��:���:��.�c�;w�t�;d� ' - ..f g�: ✓ �`b`�,,�'u�?4�'���iv��.°Fr: � � Pitched Roof Arrays Simplifiee! J ��' :���a�<�r���e�,����:���������� ��^����,�,��=�+.c�: -->'�Y ,r,:, ,., The SnapNrack Series 100 UL Roof Mount System �-:�::�,k�w� ����'���. 't`,',�t'�,.�...f✓:;:f,�.Ql;;t?�`�1.`. ��` .r. ,Y is an efficient, visually appealing, photovoltaic (PV) _ �"`'P�:�;`�``'r';fi;��;5'�cc:�°, `.y'';�'����i� �-;�'R;'X-a t�i::?Fi"�C�:n;' ..xr;4:,,r� '�"'Y'""i��Yx:�,t��+ . - _ . module installation system. Series 100 UL is Listed �--•- � — — --�— to the UL Standard 2703 for Bonding, meaning that ' � all system components have been Certified by UL for � Roof System in 4 Simple Steps: ! electrical continuity, eliminating the need for additional f � � �, 1) Go to the onlme Senes 100 Configuration , grounding hardware. The System's components provide , Tool (configure snapnrack com) and select � an adequate bonding path which has eliminated the I "Yes" for UL 2703 Listed � need for grounding lugs and washers at each module, � � , and bonding jumpers between splices. The UL 2703 i 2) Identify Site Conditions (Array Tilt, Building Listing ensures that SnapNrack partners can provide � Height, Roof Type, Wind and Snow Loads) � the best in class installations in quality, safety, and � 3) Build array in the online Configuration efficiency. �Tool and automatically generate a Bill of Materials • All bonding hardware is fully integrated into the ; components 4) Place order with your distributor Purchase material for a single pro�ect or order in bulk , • No grounding lugs required for modules � for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail . channel, no drilling of rail or reaching for other tools • required (One Lug per individual row of modules) • Class A Fire Rating Type 1 and 2 modules O` LISTED PV Mounting System Patent Pending 2703 —Stainless Steel .—SnapNreck Bonding --SnapNrack Standard Rail —Stainless Bolt with �•�� Splice Insert Split-Lock Washer Bolt with Split- Lock Washer ��"'�� ' —SnapNrack Bondmg _ �—SnapNreck �SnapNrack � Ad�ustable End gonding �'1T gaslee Clamp Top Mid Clamp "��'" SnapNrack ��—SnapNreckBonding �_ \ � Bonding �� SnapNrack Stamless — Ad�ustable End Bonding '�� Channel Nut Clamp Bottom � Stainless Hardware wrth Bolt wrth / Channel Nut Split-Lock Washers Split Lock SnapNrack Bonding SnapNrack Bonding SnapNrack Bonding Washer Adjustable End Clamp Mid Clamp Standard Rail Spllce SnapNrack � Ground Lug 10-6 AWG— _ _ ,y,, Copper Wire � P SnapNrack Ground Lug � � , .� Assembly d (ONE RE�UIRED PER ROW OF q MODULES) � SnapNrack Bonding Universal End Clamp(UEC)Wave _> �i —UEC Pull Strap % s,^_:� —UEC Wedge �Stainless Steel Bolt with Flat Washer, SnapNrack Bonding Unlversal End Clamp SnapNreck— Bonding �, i Standoff �,5!�% � Clamp Assembly SnapNrack—� Serrated Stainless_� �SnapNrack SnaPNreck Bonding Rubber Steel Flange Nut Bonding �Channel Nut Rain Collar � Channel Stainless Serrated Stainless— Nut z�^ Flange Nut Steel Flange Boit —SnapNrack �Stainiess SnapNrack—� g2 Degree � Flange Mill Finish Bolt Standoff L Foot $ �, �SnapNrack SnapNreck� � All Purpose Mill Finish � L Foot Standoff � SnapNreck �SnapNrack Base(7-Hole SnapNrack�� �—L Foot Metal Roof Base Shown) '� Mill Finish � Flashing Base Assembly � L Foot Base � , SnapNrack Bonding SnapNrack Bond(ng SnapNrack Metal Roof Base with ' Standoff Assembly L Foot Base wlth Flashing Bonding L Foot • • • � . Materials • 6000 Series aluminum - • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish • Clear and black anodized aluminum , • Mill Finish on select components Installation � Quick and efficient mounting •Ad�ustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs. & Certifications •�Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification • • Class A Fire Rating Type 1 and Type 2 Modules _ � • Stamped Structural Engineering Reports for all 50 States � Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship (download full details at snapnrack.com) Snc����:���',� r�ck� � _ t:'�_�� e"..'+nc..,i1.�r�y"v _'t ;'i�'9s1:� (877) 732-2860 www.SnapNrack.com � y � Printed on recycled paper using soy based inks O 2015 by SnapNrack PV Mounting System All rights reserved � • � � � • • . . . - - • - . � • . - The Sna Nrack line of solar mounting -r� �l�'�'��'�� s�-����'���-•��"�`-���"����•�'"�-�� p :;i����-�'3��:���=�Yp�.:„4�. s r:�, �� ���-���`��,'�`°'�j�-�..� �' �,�.;�����:`"�. fi�;. systems is designed to reduce total _ - �� # �`� ���'� ��'~ �, �_ ���-_-�%..��, �',�.:y �� � � ='�`t.;�-**`�sf a ;s�eF�.f.+"r r'�+e n-�t. ,`c 'a_��''�--� Z.4• ...:�"f,n.r t�`„ , r�.� +ye""`" ..��.,,`v installation costs. The system features wa �� _M�„�a� ��� ��-���� technical innovations proven on more �r=y � � �`_ � - ��' � ���� .t � � F -'�` '�7 �,�«..`�- s ;-r + �t T' �. .,� � �� ..�•': s ,-�� than 300 MW of solar rojects to sim lif • - `j" �'��- p P Y =� ,�,. � �. �y.: � ..��-��,�z�., installation and reduce costs. � ��� ' '��� � - .-�' ��° � , ,�����'�`; " _; � Flashed L Foot Simplified Y''� "�" � r. r� ' sE a SnapNrack Series 100 Flashed L Foot Kit is an � r �,' ^ x� - -- • ��� � `, innovative solution to provide a long lasting watertight � , _ ___ . _____.__.______ ._ __ _ _ _. _ ___. __ ____.� seal over the life of the system.The Flashed L Foot j Flashecl L Foot in 4 Simple Steps: , provides a fully flashed roof fastener for attachment to I 1) Locate a rafter in the roof using a pilot � � drill composition roof with no required cutting of shingles. I j The L Foot is engineered for maximum adjustability for i 2) Install base to the roof on top of the i � composition shingle I • a clean level installation. � 3) Use a breaker bar to separate the � • 1"slotted bolt connection composition shingles above the base, � and install the flashing � • 1"spacers available for increased ad�ustability I 4) Attach the L foot on top and proceed with • Clear or Black anodized aluminum components rail installation and leveling � (both available with black flashing) I , Place order with your distributor Purchase j • No Cutting of shingles material for a single project or order in bulk for additional savings � Patent Pending »—.�----_______.�.___-----___.�..---� ---_._--____--- ------- _ - - ------- - --�-- - - -- -- --� � . �r+ � � � . ,� ` � � ' ' I � _ � � � f � � - , � t � � _�,;� � o , - ! + � � ��� � �_ . i � - I ; o - � + ; ----=- L.....------ ------------------------- ------- •__.__.� �_.�.�_.—t L_._....__ . . -- --- - �.__.._�; Flasl-�e�l L Foot I�i[Paiis Flashed L FGGt ICit Assembled Flashecl L Foot Kit Assembly Flashed L Foot Kit Dimensions SNAPNRACKCHANNELNUT SNAPNRACK920EGREELFOOT,CLEARORBLACK 5N6-18 FLANGE NUT 6 5//6•18 X 1 IN BOLT WITH �SPLR LOCK WASHER SNAPNRACK GOMPOSITION FLASHIN6 .•'` � 7 _ � rop0 - � 343 SNAPNRACKLFOOTBASE � • 68 . • ' • • • � . Materials 6000 Series Aluminum L Foot&Base � Stainless Steel Hardware Galvanized Steel Flashing w/black all weather coating Material Finish Clear and black anodized aluminum � Weight 1 3 Ibs � Design Uplift Load 350 Ibs Uplift , Design Ultimate Load 1,000 Ibs Uplift Warranty 10 Year matenal and worksmanship SnCI��' �.-'{ rG1C�i�' r� ,:<��C� 5 �+`�i.f,1�6��a� �5,>6���U'�:t� (877) 732-2860 www.SnapNrack.com � Printed on recycled paper using soy based inks O 2014 by SnapNrack PV Mounting System All rights reserved .�_ . "'= � �����°����� � �������� ������� - . uM -UTILITY METER V NOTES - BUILDING REVIEW NOTE �E pF W ; so -SERVICE DISCONNECT I. An I S" wide clearing (free of solar TOWN BUILDING PLANS EXAMINER NAS REVIEWED Tt1E T'"�� s -MAIN SERVIGE PANEL ^ eauipment) shall be prov�ded along at least ENCLOSED DOCUMENT FOR MINIMUM ACCEPTABLE `'� . r ���,g�l �f��°���'3 �l-� C�DE oF one side of the roof ridge on the same PLAN SUBMITTAL REQUIREMENTS OF Tt1E TOWN AS 3 � -V E N T P I P E ���,� Y��� S!�'�� V V�I C ODES si de as t he so lar eauipmen t or on ano t her t '"=v _INVERTER side of the ridge that does not have solar SPECIFIED IN TF1E BUILDING AND/OR RESIDENTIAL � AS REQI��r�iE� � ' equipment on it. In addition, an I 8" wide CODE OF TI1E STATE OF NEW YORK. THIS REVIEW , PPv -PANEL Pt10TOVOLTAIC , i � pathway (free of solar equipment) shall be DOES NOT GUARANTEE COMPLIANCE WITti TI1AT `�-�g�,�. � -FUSED - AC DISCO ` - provided from at least one eave or gutter CODE. TNAT RESPONSIBILITY IS GUARANTEED UNDER � i�(���Tp�NpLklv��iNG OARD connecting to that I 8" roof ridge clearing. ThE SEAL AND SIGNATURE OF THE STATE OF NEW -AC DISCONNECT 2.Roof shall have no more than a single layer YORK LICENSED DESIGN PROFESSIONAL OF RECORD. isr -LINE SIDE TAP " ', i1T pw� 'RUSTE�S of roof covering m addition to the solar Tt1AT SEAL AND SIGNATURE t1AS BEEN INTERPRETED 'L' co -DC COMBINER BOX � � iNv equipment. AS AN ATTESTATION TF1AT, TO Tf1E BEST OF Tf1E p w � c� i�•�•�•n� = 3.Installation of solar e�uipment shall be LICENSEE'S BELIEF AND INFORMATION ThE WOR K IN z � � � e x r� -E X T E R I O R L O C A T I O N �"'�`"""—""`w �B� �, flush-mounted, parallel to and no more than isr� -I ST FLOOR LOCATION �T 5 ThE DOCUMENT IS: � � Q - 6-mches above the surface of the roof. MACCURATE "�' � � �s� -BASEMENT LOCATION -- � = z U 4.Weight of the mstalled system shall not yCONFORMS WITt1 GOVERNING CODES APPLICABLE O � � � te� -GARAGE LOCATION exceed more than 5-psf for AT Tt1E TIME OF Tf1E c� � O ~ u� � photovoltaics and no more than 6-psf � z � for residential solar hot water systems. SUBMISSION U O � Q � 5.Any plumbing vents through roof are not "CONFORMS WITFi REASONABLE STANDARDS OF v � � to be cut or covered for solar installation. PRACTICE AND WITF1 VIEW � �����Q'��� �� ����� Any relocation or modification wili rec�uire TO TI1E SAFEGUARDING OF LIFE, 11EALTh, PROPERTY ��� plumbmg permits and inspection. AND PUBLIC WELFARE � � g.p,i� m � 6.Installation of solar ec�uipment will be m IS TF1E RESPONSIBILITY OF TI1E LICENSEE JOB# DATE: full compliance with all current NEC I 6 I 30 F BY'.� requirements. MOUNTING BRACI'�TS AND h1ARDWARE MEET OR EXCEED ' NOTIFY BUILDING DcP�r�TIl�iE�17 AT STRUCTURA� STATEMENT NYS CODE REQUIREMENTS FORTf1E DESIGN CRITERIA 765-1802 8 HM TO �PM ��R THL FOR TI1E TOWN. � �, Tf1E EXISTING STRUCTURE IS ADEQUATE TO � � FOLLOWIPJG INSPECTIOPIS: � `�` - SUPPORT THE NEW LOADS IMPOSED BY Tf1E TI1E ACTUAL IN-FIELD AT'fAC11MENT TO Tf1E ROOF WILL W �` � 1. FOU�DATION - TWO REQUIRED PIIOTOVOLTAIC MODULE SYSTEM INCLUDING MEET OR EXCEED NYS RESIDENTIAL CODE 2010 RCNYS � �} n FOR POURED CGh1CRETE ��� UPLIFT � S11EAR. TI1E EXISTING RAFTER SIZES � REQUIREMENTS. � 2. �iOUGH - FRAP�ING & PLU^��ING uM s�o DIMENSIONS CONFORM TO RCNYS TABLE FASTENER REQUIREMENTS: z �o � 3. iNSUL1�TI0N R 8 0 2.5. I (I) - R A F T E R S P A N S TOTA L A R R A Y A R E A = 3 2 2 5 F � �Q � WIND LOAD: ASCE 7 (SEE CALCULATIONS TI11S ShEET) W �° o 4. FINAL - CONSTRUCTION P�UST (18)PVMODULES BE COMPLETE FOR C.G. 4 I .5 P S F z a� o ��������� �� 51TE EVAL. �JOB NOTES TOTAL UPLIFT = 4 I .5 PSF x 322 SF = I 3,363 LBS O W � A L L C O N S T R U C T I O N S H A L L I� F ET 1-HE � � m w R E Q U I R E P�E N T S O F T H E C O D OF N�W I . SEE E-I FOR SPECIAL CONNECTION NOTES F A S T E N E R: z � o � YORI< STATE. NOT RESPO,NS E FOR�ULL t10USE ROOF PLAN �S� �� ���� ��� LAG SCREW SPEC 203.2, 8/04: (FLAT WASIIERS REQ TO z ,� BE USED WITI1 LAG BOLTS) i DESIGN OR CONS1r�UCTION RORS. SCALE NTS �������� ������g���� LAG BOLT WITFiDRAWAL VAWE; 5/16" DIA., 266 LB/IN X � � 2-IN Tt1READ DEPTt1= 532 LB. CAP. EACI1 p � � � ADDENDUM INFORMATION MIN. NUMBER OF LAG BOLTS REQ. = I 3,363 LBS/ 532 � �� �������� -- - ` " A. PSEGLI REBATE DISCLOSURE; STANDARD LBS/LAG BOLT = 26 z N Wo �- ' '- TOTAL RAIL FEET = I 22'-0" RAIL FT/ 26 BOLTS = 4'-8" z �o INSTALLATION PACKAGE OUTLINE � MAXIMUM SPAN BETWEEN MOUNTING FEET BOLTS "X": W �Z TI1E PV SYSTEM t1AS BEEN DESIGNED TO MEET Tt1E MINIMUM DESIGN STANDARDS ° � �� IW_— g�c FOR BUILDING AND OTIIER STRUCTURES OF Th1E ASCE 7-05 � RCNYS 2010. USE 4-8 MAX. � m o� z Z� INVERTER#I- 5E5000A-US INVERTER- N/A SYSTEM INFORMATION ROOF � STRUCTURE � � o Z R.R.'S ARE ~ `° MODULE (I 8)LG MONOX LG3 I 5N I C-G4 KAFTER/SPACING 4"X 6"/28"O C I— o N Z � � s � � � � e � INVERTER• (I)SE5000A-US ACTUAL SPAN I 2'-5 5" DOUG FIR#I � _ �• - I 6 2 •� - O O i O P T I M I Z E R (I 8)P 4 0 0-2 N M 4 A R M M C 4 S F 1 E A T H I N G P L Y W O OD - �- -• r.. 350 O •- -� o• � O.o LC� MODEL MONOX, LG3 I 5N I C-G4, ' STRINGING (2)STRINGS OF(9)MODULES ' COLLAR TIES I"X 2" @ RANDOM n RACKING SNAP'N'RACK-SERIES I 00 UL 2703 'TYPE!L.P�YERS ARCH ASPt1ALT/ I o • s o o.o . • o.0 3 1�5 W A T T E A., 6 4.5 7"L x 3 9.3 7"W x PACKAGE PEST CONTROL SCALE I .57��D, 17.65 FTz SYSTEM RATING(DC): 5 670kW 3/I 6��= � � •- 30.0 •- O O 37 48#/MODULE (2. I#/SF) 04/20 I 3 EST PRODUCTION(AC)• 5,29 I kWh/YR JOB hARDWARE/ QTY. , EST PROD SOURCE. SPC I 22"RAIL.I 2 ENDS-8 DATE : �'�'' �"�� I62"RAIL O MIDS 32 �'i'-�'-��� CLIMATIC � GEOGRAPNIC DESIGN CRITERIA - TABLE R30 I .2( I ) ADDITIONAL MATERIAL NEEDED ������� NYSERDA L-FOOT 28 LUGS•2 5. 13. 16 ��a�`� INSTALLER I . N/A SPLICE 8 OPT KIT 18 GROUND WIND SEISMIG SUBJECT TO DAMAGE BY WINTER ICESFIIELD FLOOD PAGE , �� ,--- ,,- NUMBER 8"X 100'SCREEN.I U-ANCt10R N/A � - t�� �� SNOW SPEED DESIGN DESIGN uNoewnY- ryqZARDS '�'�� ��="�� LOAD (MPFt) CATEGOR WEATFIERING FROST LINE TERMITE TEMP MENT LOCUS METER N/A DEPTti REqUIRED A 1 SOLAR SYSTEMS 4355 � Mop To g SEE ' • Po�rering your world 20PSF izo B SEVERE 3'-0" HEAVY I I de NA �A�s _ �.-• � � � e ' ' ^ ��f NEw r'� h� ( I) F011 SOUTII ROOF �} l9 U I 9 I°TRUE; 34°TILT; 8/I 2 PITC11 x o i ( I 8) MODULES �� RIDGE �� �� S I - . ,- `S2" � � `�, .�j- ' •, 53 �p�' w U w O w � N _ - V - �F: . .i ... . . . _ NP_ Z ^ � m \ a =' �� W � Q � � SNAP'N'RACK SYSTEM O � O � (TYPICAL RAIL � p � � — — — — ACROSS EACFi ROW . U O � Q OF ENTI RE ARRAY) o m � (Only Two Shown � � ROOF AREA for Clarity) S7 56 S5 S4 JOB# � 39�-i i%2�� I 6 I 30 GUTTER PHOTOVOLTAIC � '�� MODULE (TYP) � o � � ' , w � q ' U w— � . j �}: ron � � �z _ w W W m (� _� to C� N a � Z �� v�i � / W �� O Z J O O I p W �o N � � m w Z w O � S� _ � �4 S„ � cn � • . Z � Pf10TOV IC MODULE - � Ridge � � Q n �I� n I Z a z N� Rafter - � w o I \ �Z 4"X 6"/ 28" O.C. � m N° DOUG FIR#I � � � g° _ . � o 2'-5.5" m Z� ACTUAL SPAN sot�c � � �o . � � �� ROOF SECTION (Typ) • . � N� , SCALE: NTS i � I I SCALE 3/I 6"= I ' DATE ��,`���� PAIZTIAL 1--IOUSE ROOP PLAN ��.�m`' NY9ERDA SCALE: 3/I 6" = I '-O" 5. I 3. � 6 ���r I NSTALLER ��������.� �� NUMBER - _ PAGE SOLAR SYSTEMS 4355 ' ' ��� Pouvering your world APPROVED BY: - , - ♦ ' I ' :� � ' - l.���f N O �� � _.s � i _ UTILITY ��� SERVIGE � � 2 8 9 INVERTER with integral DC ^ ^ _-e , Pv nno�u� ` SAFETY switch ��/� U w J'`L �P, ' �" � w � N STf�ING I • • • • • • � • • • • • - z o w � O - � > - w Q �CRCOTRCE _ � 'TAP' *INSTALL W - _ � � �P� POWEROPiIMIZER O _ MAIN � 2P I OOA O � O � ���_ SERVICE OGPD MAIN' � p � � _ _ . . . . . . . ■ ■ . . . – _ . � p�Op p�^ IOOA U o � � – – STRING OF – – — � (9) LG3 I 5N I C-G4 MODULES W/ - � I OOA � (9) OP-400 CURRENT LIMITING OPTIMIZERS (� • I 2 IN SERIES CIRCUIT 8 9 DC AC � _ _ � mput outpu 2 I 3 JOB# �{;,° . . ��� N I � � I 6 I 3 O �` I STRI N G 2 . . . . . . . . . . . . - I � — — " � � � 'TWIN EXISTING cri � � � I ' MAIN SERVICE I 5A BREAKERS TO U W— � SE5000A-US INVERTER PANEL CREATE ROOM FOR � �z ^ TRANSFORMERLESS/ UNGROUNDED q. NEW MAIN• n =� � � _ _ – – I 20/240 VAC I-PI1 c� �n a � ■ ■ ■ ■ ■ ■ . . . . . . – – — z ,�o � – – STRING OF = _ — MAX 2 I AMP BUILDING w �o � (9) LG3 I 5N I C-G4 MODULES N// �'-� � o (9) OP-400 CURRENT LIMITING OPTIMIZERS GROUNDING z o ELECTRODE z �X o IN SERIES CIRCUIT � �O � 3 m W z = O � . CONDUIT AND CONDUCTOR SChEDULE � � � z TAG DESCRIPTION OR CONDUCTOR TYPE CONDUCTOR NUMBER OF CONDUIT CONDUIT RUN � � � GAUGE CONDUCTORS TYPE SIZE LENGTH � Q � I PV WIRE I O 4 LFMC I .25" I 6' g Z �° EGC 6 I LFMC I .25" I 6' ~ Z s� PV WIRE I 0 4 PVC SCh. 80 I .25" 30' w Z om EGC 6 I PVC SCH. 80 I .25" 30' � o �° . PV WIRE I 0 4 LFMCIEMT I .25" 36' "� ! EGC G I f LFMC/EMT I .25" 36' � , i 2 THWN-2 6 3� PVC SCF1. 80 I .25" 2' � SCALE ' EGC/GEC - 6 I PVC SCh. 80 I .25" 2' � 3 THWN-2 6 3 PVC SCH. 80 I .25" 2' 3/ I G"= I ' 4 GEC 6 I N/A N/A 12' ' DATE �� ��� 5. 13. 16 ,,:,,,:�::�.��.� . ��'��.��� NYSERDA �v�v� I NSTALLER " ����������� NUMBER - PAGE , SOLAR SYSTEMS 4355 � E�1 � Powering your worid