Loading...
HomeMy WebLinkAbout40448-Z '' �U&Faj� Town of Southold $.41 h-.5 co, �, 5/12/2016 .41 P.O.Box 1179 w rt 53095 Main Rd �'✓ cf.„ �N.'�j3C Southold,New York 11971 . a ,I� , CERTIFICATE OF OCCUPANCY No: 38315 Date: 5/12/2016 THIS CERTIFIES that the building GENERATOR Location of Property: 150 Laurel Way, Laurel SCTM#: 473889 Sec/Block/Lot: 125.-4-24.21 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 1/28/2016 pursuant to which Building Permit No. 40448 dated 2/2/2016 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ACCESSORY GENERATOR AS APPLIED FOR The certificate is issued to Raica,Kathleen,&Peter of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40448 03-29-2016 PLUMBERS CERTIFICATION DATED Authorized Signature TOWN OF SOUTHOLD /0 4641Gts BUILDING DEPARTMENT Ig TOWN CLERK'S OFFICE o� o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40448 Date: 2/2/2016 Permission is hereby granted to: Raica, Kathleen, & Peter 150 Laurel Way Laurel, NY 11948 To: Install an accessory generator as applied for. At premises located at: 150 Laurel Way, Laurel SCTM # 473889 Sec/Block/Lot# 125.-4-24.21 Pursuant to application dated 1/28/2016 and approved by the Building Inspector. To expire on 8/3/2017. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO -ACCESSORY BUILDING $50.00 Total: $235.00 Buildin. Insp-c Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less"than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance,from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets;building and unusual natural or topographic features. 2. A properly completed application'and consent to inspect,signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy,-New dwelling$50.00, Additions.to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate ofOccupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 "Date. New Construction: Old or Pre-existing Building: J/ (check one) Location of Property: \SD LAUNel._ U House No. Stc)e\-t.."..C.---Q_A-- re t Hamlet Owner or Owners of Property: Cti r'�� .. c i Suffolk County Tax Map No 1000, Section Block Lot z-4 . i Subdivision •-A Filed Map. Lot: Permit No. 4(fr Date of Permit. Applicant: Health Dept. Approval:, Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: v (check one) Fee Submitted: $ 5b €11° •pplican ignature lei*clf SOI/43,- Town Hall Annex �� ® : Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 11799 �` .r roger.richertRtown.southold.ny.us Southold,NY 11971-0959 :�—a - -®eels = COM, ' ," ,.‘° BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Raica Address: 150 Laurel Way City: Laurel St: New York Zip: 11948 Building Permit#: 40448 Section. 125 Block: 4 Lot 24.21 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: All Wright Electric License No: 43457-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel NC Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment 20 KW Standby Generator with 14 Circuit Transfer Switch Notes: Inspector Signature: g. 1 Date: March 29, 2016 Electrical 81 Compliance Form.xls /_ . FIELD 1216`13MON=PORT CODATAU S S • . ..t, 1 FQtNDAfloN(1sT) • • • • FOUNDA,TSQN(2ND) • i q • O • .moi I 1 y ROUGH FRNINCx& r PLUMBING �..__._ , . • . , • , • • • • a . . . . , .,..........._ , . ., • • • mi_ . _ . ,_ . ......__ . . . . .... . . TNSULATZON'PEA N,Y. H STATE ENERGY CODE _ • • ' FTNAL . . 1. _ ..• ..� .. , 461 ill (7 - 4'-eal. 4; Af ig,P10 . ... . . . • . . . . • k , . 2 J r . . . . - - -,�o-�--+ . .) z . . . . . .., .. . - e ., .• 4 , r .,1 1. ' . ..r i .. ', 1 ,,. .• h r .r....� . h y' • .. v' . TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans , TEL:(631)765-1802 Planning Board approval FAX:(631)765-9502 11U I Check urvet' SoutholdTown.NorthFork.net PERMIT NO. Septic Form N.Y.S.D E.C. Trustees C O Application �n Flood Permit Examined t ,20 i// Single&Separate Storm-Water Assessment Form Contact: Approved 49\- ,20 1 Mail to. Disapproved a/c Phone. i/ �> -rf Expiration ¶a - 20 / / y \D 0 i, , ::' , B R +ector ~►'� � ; APPLICATION FOR BUILDING PERMIT ' 1 JAN 27 2016 E!. I Date 1/1,5-1 ,20 /,6 __ ___-_ _- \ INSTRUCTIONS a.This app licationlaIST be completely filled in by typewnter or in ink and submitted to the Building Inspector with 4 ___---- sets-ofvp'lan's,accurate plot plan to scale.Fee according to schedule. \, b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and m building for necessary inspections. •j (Si: ature of applicant or n. .i-, a corporation) / O, can •. .L I. — 41A l 196 (Mai g a'dress of ap.0 cant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder EZ Ce:r\Zt C l Av� Name of owner ofpremises ��Tib LF€ A J � T�/; kite-I A (n Oi f Cat) (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer (Name and title of corporate officer) Builders License No. , Plumbers License No. Electricians License No. Other Trade's License No. - 1. Location of land on which proposed work will be done: 5-0 : V tv I House Number Street Hamlet County Tax Map No. 1000 Section 1 Z5 Block Li Lot 2q . 1 1 { Subdivision Ui (,(,t) Filed Map No. Lot 22.( , 2 / 2. State existing use and occupancy of premia d intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work AO $4 %AAAI 947'l J(Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor ' If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existmg structures,if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12.Does proposed construction violate any zoning law,ordinance or regulation?'YES ' NO 13.Will lot be re-graded?YES `NO Will excess fill be removed from premises?YES NO 14.Names of Owner of premises Address Phone No. Name of Architect - Address,., Phone No Name of Contractor ALL id 21 blit (C Address O361C I b57 Phone No. (03I 353-3q I 1 S&UrkA jb ,) /Of. 1,196.5 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetrand? YES NO *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accuratefoundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO *IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OFS I G lit Oil d (pia 1(y(7— being duly sworn,deposes and says that(s)he is the applicant Game of individu 1 signing contract)above named, (S)He is the ` O•AIT/1A- tt— (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authonzed to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this" /� II MEWS V.Bim' a-1 day of f NiV, .\ 20 ) opporp.. RACY 3,4State of 74 al -I ,�oSUIOft 6a'AUfI7 Notary ' blic S717 e of Applicant 4=4041 f Town Hall Annex * * Telephone(631)765-1802 54375 Main Road \ H �� p2 P.O.Box 1179 • •c` �� roger.richertCa town sout�i0fa.ny.us Southold,NY 11971-0959 �'� ` pi� . BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: (DJ-MA CMAC Date: // 57/1/A Company Name: A G0/2_1 kyr E Le-C-7 21 C - Name: ie>✓IA�i� W21 (21477 License No.: `I 3 S 7 - C Address: () \ 651 SOUTk 4 �N "Phone No.: ( 3 i - 3 5-3_ 3q 1 I JOBSITE INFORMATION: (*Indicates required information) *Name: r4Tvt l EF-/k)' C -- PE--k-ev C I A `Address: 15b L A U J c L u i2rr L *Cross Street: AA ;V fLti *Phone No.: I - ` ^7 3 -b Permit No.: Tax.Map District: 1000 Section: 1 2 5 Block: (I Lot: 011 , z *BRIEF DESCRIPTION OF WORK(Please Print Clearly) • �N ST,A LLAT t f D k Z(3< k°%') S°&E S1-A -ol3y r- r t.a cc,,r-i- / 11-CA - A Pt CLA Cu c Ew roc v` (Please Circle All That Apply) *Is job ready for inspection: YES NO Rough In Final *bayou need a Temp Certificate: YES NO Temp Information(If needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION -82-Request for Inspection Form GV�fi� i&,v 87 G�l 4 i.v4 ,2J /i(, l T----- ..,-,-----,- 46W-r • '.; -,,.v -' 16 O0 - , 2 S _1-1 -24, 1 TOWN OF SOUTHOLD PROPERTY RECORD CARD V„—IVy 1'9K OWNER STREET / 5 ) -VILLAGE DIST. SUB. LOT Z s" �� k<c"- .� 4-c-r L� A,Te 1' Way Laurel/ Mo -R- 1 z Lave I LVAS n ie - lo ACR. 2 REMARKS TYPE OF BLD. +* a D 001D 31(3o/D9-Li a I-7 /0970 -1_60,1-6-i Lr)ks -a /eat'ca_.$ vv-r. PROP. CLASS LO,v it e L LI tri1--+-8.(KS L-- • .VD 4 a? 0Ll e)P � 0-(0 - rlcui dwol►>1 LAND IMP. TOTAL DATE L}'2G 1� 3 (• 4.lazes lP S/02-(02._ _ [ f I l' 12/62 ( 13Joh 13P4 339s3 re.plates 13 P--* 313Lf0 0 X10 >( 232 / M t/�# Reolt, ok-f 2 400 �`�('�� . L1OOj r r 8162 1 j/1A)og $f # 3�t3D ► r4eyr'o( . A)-)-e� Po c # r. .a, , AZ14 (2t „P\ coc P ( (o00 i(I7(DG 31 y (►3 - C�P4 3763d — 5ola- -panni• C42_ 3653? aoo 6000" S6 oo " . 260Q /57 , / 8'300 '. 31/10N —2_6(90 MVA 159 00 ' 3/1/08 --- c<0n , /3-3=0V / 79OO z/ c//o 4 26O0 /3. 300 /5- 700 /e4., / 0 2600 Q.3 0 /449 00, 1/ 3/1 64 FRONTAGE ON WATER TILLABLE FRONTAGE ON ROAD WOODLAND DEPTH MEADOWLAND BULKHEAD HOUSE/LOT --- - I TOTAL 1.5 y c Irl. :.1,-',.+-11111 � f q _ � 3 Q ", �'S '.e�k`c'gC•. l'''''''4444 i�f4 �I�� - 1j 14`.'4C '3•c Lq:6}�',i`'"iL�M. II�-C (Sao�,� V -7t� ,�, '.a„ i�iy.�.� a 6. r f" +�.+, �r� 1) `K:. r ih,,, r= ,._f a _7.j rr i 4y 't i ��'� �,-,7,-.:1-4, ,„„---.1b,' .3 Z 1, ''. ' -€iy .,, u.,xT..�`-2, p �, ! ..._-11,,.-1 F - yrs }41tlA' ¢ p 4 �. 1 et ,s. < i �' - 4pL.z—.,�^ h ra _ 9�� _ / a LJ2TZ. 4.- M .t - by rg .' ` 3 fir z IA t 1CC'�If k `t r j 1.. 2 `--•:7"-'47',�" A w. �y�. ...,,,„. .SV, a"n fr, .x. _.e..?.. ,,.wR ;y._ -�f.�' t4 1,,�,ca.6? • IR&T f / n />: " ;'':x`- " a1. � zti � n '{ vh*t3i' �- A" • F3 �^'`Q' f 17()Y 7.A..--` • L +-r",,,. .a......'r x f° M -1 i... a' ...:_`__"`.A," — _ w�... ��r .. 'h'''.; -,�r*'< • l 125.-4-24.21 3/08 t - y [ - ls-t- Z1...�- q.,y\to t 13 fi .T'9P C> 1 r'C'.IC.f•Cf k9..."4"!VN. / t M. Bldg. �p1-21,---. ` , .2 I �3 Foundation C8 Bath L ( 2_— FULL } LAB Ex�e�si�otn �.s p€r of n 2 7! 5 3p5 /Q 7'( Basement S L Floors rle� C� Kit. v�r, c ____[_. Extgnsion ,. c Ext Walls Interior Finish sl L R. .�� cam, t 1 �Li- I z,0 0 _ 3 Li i S _ S tQi �e� � � s Exsoq'ren Pe4. Ptatng ! Fire Place Heat45 `7 D R Patio W vet . 1.G.:f:,. 1={1;-,tom,,.. BR15 psrm<' bsni 8IZ1. 5 Fin B Porch to b, /,00 /018 er Me. L -it b., SPOT �oO Attic -7,4,,E r ,_13y.�.a /-ick to = 0 P 2,5' ( � O Rooms 1st Floor (1a�rt Garage rl � 19 �! �I ZS J�� Driveway Rooms 2nd Floor rp � w- / $ Pool . , : . Z ----I-76' 77.1l a i.Xf V....t e`,. l �t 1lJt {Sf {L'v\I G t a 2 �y ,ri lr� REF. 0 -7----- - .. - - - - 26 .00` r .,•-" --.... : . -70;1 / f0 1= / t / L.3 I 111111111111 w f ' NOTE: TOP OF RIDGE a�� AT DATUM 133.4± PROPOSED / , 69.6/1 AIVA TWO STORY FRAME HOUSE 3�;$„ Ng (4 BEDROOMS) 1 \ F.F. = 1042 r�� �, Irn fr \ ���p L y 41 A D \` � iceR = 55.0 41- '/ � LAUREL WAY e. + fi SITE PLAN OZ. 141'ce... APPRIVED AS NOTED ELECTRICAL DATE: �.P. INSPECTION REQUIRED FEE: 0 1 I � BY: ... _di NOTIFY BUILDING DEPART'.' AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED RETAIN STORM WATER RUNOFF FOR POURED CONCRETE PURSUANT TO CHAPTER 236 2. ROUGH - FRAMING & PLUMBING OF THE TOWN CODE. 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF SOU L D TQ N TR ISMS ItYSTEC- OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY GENERAC® N N N 15/20/22 k , GUARDIAN® SERIESto Residential Standby Generators Air-Cooled Gas Engine 1 of 5 INCLUDES: Standby Power Rating • True PowerTM Electrical Technology Models 006459-2, 006461-1, 006462-2 (Steel-Bisque) - 16 kW 60 Hz • Two Line LCD Multilingual Digital Model 006721-1 (Aluminum-Gray) -16 kW 60 Hz EvolutionTM Controller (English/Spanish/ Models 006729-2, 006730-1 (Steel -Bisque) -20 kW 60 Hi French/Portuguese) Models 006551-2, 006552-1 (Aluminum-Gray) -22 kW 60 Hz • Two Transfer Switch Options Available: 100 Amp Pre Wired Switch or ,. „ .- 04: 200 Amp Service Rated Switch. s See Page 4 for Details. • Electronic Governor - ,,° `.,moi ro • External Main Circuit Breaker, System Status& _�=''° --* " Maintenance Interval LED Indicators ' N� «« • GFCI Duplex Outlet _" :,. ;°`" C ENERA,C' ^; • Sound Attenuated Enclosure i' ` t 'a'"r " '""- • Flexible Fuel Line Connector ` '°. g� • Composite Mounting Pad ` • Natural Gas or LP Gas Operation CO US QUIET TEST LISTED • 5 Year Limited Warranty Note CUL certification only applies to unbundled units and units packaged with pre-wired switches • Capability to be installed within 18" (457 mm) Units packaged with the Smart Switch are UL certified in the USA only of a building* *Only if located away from doors,windows and fresh air intakes,and unless other- wise directed by local codes FEATURES 0 INNOVATIVE DESIGN&PROTOTYPE TESTING are key components 0 SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. of GENERAC'S success in "IMPROVING POWER BY DESIGN"But it This state-of-the-art power maximizing regulation system is standard on doesn't stop there Total commitment to component testing,reliability all Generac models It provides optimized FAST RESPONSE to changing testing,environmental testing,destruction and life testing,plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by to applicable CSA,NEMA,EGSA,and other standards,allows you to electronically torque-matching the surge loads to the engine. Digital choose GENERAC POWER SYSTEMS with the confidence that these voltage regulation at±1%. systems will provide superior performance. O TRUE POWER"" ELECTRICAL TECHNOLOGY: Superior harmonics 0 SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer and sine wave form produce less than 5% Total Harmonic Distortion for network provides parts and service know-how for the entire unit,from the utility quality power.This allows confident operation of sensitive electronic engine to the smallest electronic component. equipment and micro-chip based appliances,such as variable speed HVAC systems. 0 GENERAC TRANSFER SWITCHES. Long life and reliability are O TEST CRITERIA: synonymous with GENERAC POWER SYSTEMS. One reason for this PROTOTYPE TESTED r NEMA MG1-22 EVALUATION confidence is that the GENERAC product line includes its own transfer f SYSTEM TORSIONAL TESTED ' MOTOR STARTING ABILITY systems and controls for total system compatibility w GENERAC I tiAl�'3ss ��,� +Li4_ * LL•I®• * * MobPROMISE ENGINEERED PP* LinISO BUILT ' 'OMEP r' 4BHA oD v. TM +Built In the USA using domestic and foreign parts GENERAC® 16/20/22 kW features and benefits CV Engine Cfl •Generac(OHVI)design Maximizes engine"breathing"for increased fuel efficiency Plateau honed cylinder walls and plasma moly rings T helps the engine run cooler,reducing oil consumption resulting in longer engine life •Quiet-Test- Greatly reduces sound output and fuel consumption during bi-weekly exercise,compared to other brands. •"Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. 2 of 5 •Electronic ignition/spark advance These features combine to assure smooth,quick starting every time -Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life Now featuring up to a 2 year/200 hour oil change interval •Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil •High temperature shutdown Prevents damage due to overheating Generator •Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. •Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. 'Displaced phase excitation Maximizes motor starting capability •Automatic voltage regulation Regulates the output voltage to±1%prevents damaging voltage spikes •UL 2200 listed For your safety Transfer switch 'Fully automatic Transfers your vital electrical loads to the energized source of power •Pre-wired,color-coded conduits Ensures the easiest,trouble-free installation. (Pre-wired switches only) 'Remote mounting Mounts near your existing distribution panel for simple,low-cost installation. Evolution'' Controls •Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. •Two-line LCD multilingual display Provides homeowners easily visible logs of history,maintenance and events up to 50 occurrences •Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations •Utility voltage sensing Constantly monitors utility voltage,setpoints 60%dropout,80%pick-up,of standard voltage •Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. 'Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer 'Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds. •Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute •Programmable exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner 'Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature •Electronic governor Maintains constant 60 Hz frequency Unit •SAE weather protective enclosure Sound attenuated enclosure ensures quiet operation and protection against mother nature,withstanding winds up to 150 mph.Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability 'Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries 'Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18"away from a building* Installation System •1 ft(305 mm)flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe •Composite mounting pad Eliminates the need to pour a concrete pad unless required by local municipalities r GENERAC® CV 16/20/22 kW specifications o Cm Generator 006459-2,006461-1, 006729-2,006730-1, 006551-2,006552-1 Model 006462-2,006721-1(16 kW) (20 kW) (22 kW) C..0 Rated Maxfmuri Continuous Power Capacity(LP).. _„,.,.. 16,000 Watts" 20,000 Watts* 22,000 Watts* r Rated Maximum Continuous Power Capacity(NG) 16,000 Watts* 18,000 Watts* 19,500 Watts* 'Rated Voltage_ .__ 240 _240 240 _ Rated Maximum Continuous Load Current—240 Volts(LP/NG) 66 6/66 6 83 3/75 91 6/81 3 i Total Harmonic Distortion . less than 5% , Less than 5% Less than5% 3 of 5 Main Line Circuit Breaker 65 Amp 90 Amp 100 Amp Phase - ___. .. .. _._. __.. 1 _._1.._._ 1 Number of Rotor Poles 2 2 2 fated AC Frequency 60 Hz 6t)Hz 60th Power Factor 1 0 1 0 1 0 Battery Requirement(not included)_ Group 28R,12 Volts and 525 CCA Minimum Unit Weight(lb/kg) 455/206 4(Steel) 505/229 476/216 419/190(Aluminum) Dimenstons(L x W x,H)._iN_ ..___ 48 x 25 x29/1218 x 638 x 732 Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load** 66 66 67 Sound output in dB(A)at 23 ft(7 m)with generator in Quiet lost'"low-speed 60 60 58 exercise mode** . Exercise duration 5 min 5 min 5 min Engine Type of Engine GENET=OHVI V-'lWlt>) WRAC OHVI V-TWIN GENERAC OHVI V-114/1N Number of Cylinders 2 2 2 ;_Displacement 992 co 999 cc pap cc Cylinder Block Aluminum w/Cast Iron Sleeve Valve Arrangement _, Overhead Valve _ Overhead Valve Overhead Valve Ignition System Solid-state w/Magneto Solid-state w/Magneto Solid-state w/Magneto Governor System _,_, Electronic,_ Electronic _Electronic Compression Ratio9 51 9 51 9 51 Starter 12 Vdc 12 Vdc 12 Vac Oil Capacity Including Filter Approx 1 9 qV1 8 L Approx 1 9 qt/1 8 L Approx 1 9 qV1 8 L Operating rpm 000 3,600 3,600 Fuel Consumption Natural Gas ft3/hr(m3/hr) 1/2 Load 193(5 47) 205(5 8) 184(5 21) Full Load 312(8 83) 308(8 72) 281 (7 96) Liquid Propane ft3/hr(gal/hr)[I/hr] 1/2 Load 72 4(1 9)[7 2] 75 6(2 08)[7 87] 83(2 16)[816] Full Load 130(3 19)[12 07] 140(3 85)[14 57] 127(3 68)[13 94] Note,Fuel pipe must 6e sized for full fond. Required fuel pressure to generator fuel inlet at all load ranges-3,5-7'water column(7;13 mm mercury)for natural gas,:10.12"water column.(19-22 mm mercury)tot LP gas.For Btu content,mulpply;03/br x2500(1P)orft3/hr x 10t 0(NG),For Megsjoule content,multiply mWnr x93,151,14 or ma/hr x 37.26(NG) _ Controls ..._. .__...,, ._._.._.�. �. 2-Line Plain Text Multilingual CCD Display ...... Simple user interface for ease of operation. Mode Buttons Auto Automatic Start on Utility failure 7 day exerciser , _ Manual _ Start wtttt starter Catrtrot,unit stays on.If utility tails,transterto load takes place. Off d Ctl Stops unit Power is removed and charger still operate Ready tO Run/Maintenance Messages Standard _, Engine Run Hours Indication Standard Programmable start delay between 2-1500 seconds _ _ Standard(Jfrogranuttable,by dealer rutty) _ Utility Voltage Loss/Return to Utility Adjustable(Brownout Setting) From 140-171 V/190-216 V j,Future Set Capable Exerciser/Exercise Set Error Warning __._.__._ Standard _ Run/Alarm/Maintenance Logs50 Events Each Engine Start Sequence Cyclic cranking:i6-sac on,7 rest(90 sec maximum duration). Starter Lock-out Starter cannot re-engage until 5 sec after engine has stopped Smart Battery Charger ______.._ ._.__ _ 5tanctard Charger Fault/Missing AC Warning Standard Low Battery/Battery Problem Protection and Battery Condition indication Standard .. ' Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-frequency/©verload/Stpper_Overcurrenl Protection._ .. —Slat:, ldact __ Safety Fused/Fuse Problem Protection tandard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard .i Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard ;High Engine Temperature ShutdownStalydard Internal Fault/Incorrect Wiring ProtectionStandard `Common External Fault Capability _ Standard _ _ Field Upgradable Firmware Standard -'Sound levels are taken from the front of the generator Sound levels taken from other sides of the generator may be higher depending on installation parameters Rating definitions-Standby Applicable for supplying emergency pawer for the duration of the utility power outage No overload capability is available for this rating (At ratings in accordance with BS5514,1503046 and DIN6271) 'Maximum wattage and current are subject to and limited by such tutors as fuel Btu/megajoule content, ambient temperature,altitude,engine power and condition,etc Maximum power decreases about 3 5 percent for each 1,000 feet(304 8 meters)above sea level,and also wit decrease about 1 percent for each 6°C(10°F)above 16°C(60°F) GENERAC® N ' ` 16/20/22 kW switch options 0 N \ Pre-wired Features Model 006461-1(16 kW) T available an Steel 16 kW models only ,No.o!Poles.,- ._._. ----._.,_.. . „...2_ • Electrically operated,mechanically-held contacts for fast,positive connections Current Rating(Amps) 100 °VoltageMFtatirig(VAC) 120/240,.10 • Rated for all classes of load,100%equipment rated,both inductive and resistive. utility Voltage Monitor(Fixed)* 4 of 5 • 2 pole,250 VAC contactors. -Pick-up 60% -Dropout 60% • 30 millisecond transfer time. Reiurrlto Litility* .._ .. appro05 sec: • Dual coil design. • Exercise bi-weekly for 12 minutes* Standard 9 •Ell.Listed -Standard • Main contacts are silver plated or silver alloy to resist welding and sticking Total of Pre-wired Circuits 16 No 15A120V 5 • NEMA 1 (indoor rated)enclosure is standard on the pre-wired switch No 20 A 120 V 5 No 20 A 240 V 1 • Multi listed for use with 1"standard,tandem,GFCI and AFCI breakers from No.30 A 240 V - Siemens,Murray,Eaton and Square D for the most flexible and cost effective install. No 40 A 240 V 1 No 50 A 240 V1 • Pre-wired 30 foot(91 meter)whip to connect to the provided 5 foot pre-wired whip Circuit Breaker Protested , • and external connection box Available WS Symmetrical rautt Cdnent @ 250 Volts 10,000 • Pre-wired 2 foot(0 61 meter)whip,color coded to connect into the existing Function of Evolution Controller electrical panel Exercise can be set to weekly or monthly Dimensions Mechanical Dimensions Height Width DepthI El H1 H2 W1 W2 in 235 264 83 126 63 H2111:, HI mm 597 671 7 211 320 7 159 6 Wire Ranges Conductor Lug Neutral Lug Ground Lug reitIC ` 2/0-#14 2/0-#14 2/0-#14w, l i-W2 Service Rated Switch Features Model 006462-2(16 kW)/006729-2(20 kW)/006551-2(22 kW) • Electrically operated,mechanically-held contacts for fast,clean No.of Polea ..' ....v� I -_ _ . __ connections Current Rating(Amps) 200 Voltage king ?AO) .. -, _:.1W4 ,10 • Rated for all classes of load,100%equipment rated,both inductive utility Voltage Monitor(Fixed)* and resistive. -Pick-up 80% • 2 pole,250 VAC contactors -Dropout 60% -Return fb utility _.. approx 13 sec, _ •Service equipment rated,dual coil design Exercise weekly for 12 minutes" Standard conductors ,ULLfsed "` _Standard • Rated for both aluminum and copper Enclosure Type NEMA/UL 3R • NEMA/UL 3R aluminum outdoor enclosure. Withstood Rating(Amps) , •-• 22,000 _•••- Lug Range 250 MCM-#6 • Main contacts are silver plated or silver alloy to resist welding and *Function of Evolution Controller sticking W, H, Dimensions 200 Amps 120/240,10 Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 27 24 30 0 11 4 13 5 7 09 mm 692 0 762 4 289 0 343.0 180 0 I -DEPTH-. I-W2-a GENERAL® N 16/20/22 kW available accessories' `V 0 CV l Modem, Product description ._...w. mm_ __.. . a _ _ . :.. to Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ' 1- 006463-3 006463-3 Mobile Link'° access to an Internet connection from a PC or with any smart device.You will even be notified when a t change in the generator's status occurs via e-mail or text message.Available in the U.S.only. 005819 0 _ �26R Wet Cell Battery i Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact(D). 5 of 5 Tit the temperature regularly falls below 32°F(0°C),a cold weather kit is required to maintain optimal 006212-0 Cold Weather Kit battery and oil temperatures.Kit consists of a battery warmer and oil filter heater with built-in C ¢thermostats. Auxiliary Transfer Switch Contact [The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical 005621 0 Kit 'load you may not need.Not compatible with 50 amp pre-wired switches. 005839-0 Bisque Fascia Base Wrap The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers ( 005666-0-Gray (Standard on 22 p Kit* a sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. 005703-0 Bisque If the generator enclosure is scratched or damaged,it is important to touch-up the paint to protect 005704-0-Gray Paint Kit* (from future corrosion.The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. 006484-0-16 kWGenerac's scheduled maintenance kits provide all the hardware necessary to perform complete Scheduled Maintenance Kit 006485-0-20&22 kW routine maintenance on a Generac automatic standby generator. "Completely wireless and battery powered,Generac's wireless remote monitor provides you with 006664-0 Wireless Remote Monitor instant status information without ever leaving the house.Not compatible with CorePower or EcoGen systems. Smart Management Module )Smart Management Modules are used in conjunction with the Automatic Transfer Switch to 006873-0 increase its power management capabilities.It provides additional power management flexibility L___ (50 Amps) not found in any other power management system. *Note:Bisque kits are used in conjunction with steel enclosures.Gray kits are used in conjunction with aluminum enclosures. dimensions & UPCs Dimensions shown are approximate Refer to installation manual for exact dimensions DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES 637.6 mm 1218 mm [251 in] [47 9 in] i fr . ., • . . ' , r iij Model UPC �' N'€ ` " - c _, ��� 006459-2 696471064599 ' 006461-1 696471064612 "-a "-==''' i I . • 006721-1 696471067217 731 mm ,s,�='= i r [288w] ,� w,z.- _ 006729-2 696471067293 „, ----**,,,�=mow S'-' 7 006730-1 696471067309 ,s^ ni r_.^.=sit - e _ - ' 006551-2 696471065510 _.._.._._..._. ..T ;:..... ....... ....:.::.:...................._._ .......:...........°....._ _... 006552-1 696471065527 F/7/7/ 1��" /Ar„f'//% J5 /7 17, 006462-2 696471064629 �_642 mm [25 3 in] 1226 mm [48 3 in] LEFT SIDE VIEW FRONT VIEW GENERAC• Generac Power Systems,Inc. • S45 W29290 HWY 59, Waukesha,WI 53189 • generac.com ©2015 Generac Power Systems,Inc All nghts reserved All specifications are subject to change without notice Bulletin 018458-G Pnnted In U.S A 08/03/15